1
|
Kronik OM, Christensen JH, Nielsen NJ. Instrumental and theoretical advancements in pulsed elution-LC × LC: Investigation of pulse parameters and application to wastewater effluent. J Chromatogr A 2024; 1730:465079. [PMID: 38897111 DOI: 10.1016/j.chroma.2024.465079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 06/10/2024] [Accepted: 06/11/2024] [Indexed: 06/21/2024]
Abstract
Due to the decoupling of the first (1D) and second (2D) dimension in pulsed elution-LC × LC (PE-LC × LC), method development is more flexible and straightforward compared to fast comprehensive LC × LC where the dependencies of key parameters between the two dimensions limits its flexibility. In this study we present a method for pulse generation, which is based on a switching valve alternating between one pump that delivers the gradient and a second pump that delivers low eluotrophic strength for the pause state. Consequently, the dwell volume of the system was circumvented and 7.5, and 3.75 times shorter pulse widths could be generated at flow rates of 0.2, and 0.4 mL/min with satisfactory accuracies between programmed and observed mobile phase composition (relative deviation of 6.0 %). We investigated how key parameters including pulse width and step height, 2D gradient time and flow rate affected the peak capacity in PE-LC × LC. The conditions yielding the highest peak capacity for the PE-LC × LC- high-resolution mass spectrometry (HRMS) system were applied to a wastewater effluent sample. The results were compared to a one dimensional (1D)-LC-HRMS chromatogram. The peak capacity increased with a factor 34 from 112 for the 1D-LC run to 3770 for PE-LC × LC-HRMS after correction for undersampling. The analysis time for PE-LC × LC-HRMS was 12.1 h compared to 67.5 min for the 1D-LC-HRMS run. The purity of the mass spectra improved for PE-LC × LC-HRMS by a factor 2.6 (p-value 3.3 × 10-6) and 2.0 (p-value 2.5 × 10-3) for the low and high collision energy trace compared to the 1D-LC-HRMS analysis. Furthermore, the signal-to-noise ratio (S/N) was 4.2 times higher (range: 0.06-56.7, p-value 3.8 × 10-2) compared to the 1D-LC-HRMS separation based on 42 identified compounds. The improvements in S/N were explained by the lower peak volume obtained in the PE-LC × LC-HRMS.
Collapse
Affiliation(s)
- Oskar Munk Kronik
- Department of Plant and Environmental Science, University of Copenhagen, Thorvaldsensvej 40, Frederiksberg DK-1871, Denmark.
| | - Jan H Christensen
- Department of Plant and Environmental Science, University of Copenhagen, Thorvaldsensvej 40, Frederiksberg DK-1871, Denmark
| | - Nikoline Juul Nielsen
- Department of Plant and Environmental Science, University of Copenhagen, Thorvaldsensvej 40, Frederiksberg DK-1871, Denmark
| |
Collapse
|
2
|
Tirapelle M, Chia DN, Duanmu F, Besenhard MO, Mazzei L, Sorensen E. In-silico method development and optimization of on-line comprehensive two-dimensional liquid chromatography via a shortcut model. J Chromatogr A 2024; 1721:464818. [PMID: 38564929 DOI: 10.1016/j.chroma.2024.464818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 03/11/2024] [Accepted: 03/13/2024] [Indexed: 04/04/2024]
Abstract
Comprehensive two-dimensional liquid chromatography (LCxLC) represents a valuable alternative to conventional single column, or one-dimensional, liquid chromatography (1D-LC) for resolving multiple components in a complex mixture in a short time. However, developing LCxLC methods with trial-and-error experiments is challenging and time-consuming, which is why the technique is not dominant despite its significant potential. This work presents a novel shortcut model to in-silico predicting retention time and peak width within an RPLCxRPLC separation system (i.e., LCxLC systems that use reversed-phase columns (RPLC) in both separation dimensions). Our computationally effective model uses the hydrophobic-subtraction model (HSM) to predict retention and considers limitations due to the sample volume, undersampling and the maximum pressure drop. The shortcut model is used in a two-step strategy for sample-dependent optimization of RPLCxRPLC separation systems. In the first step, the Kendall's correlation coefficient of all possible combinations of available columns is evaluated, and the best column pair is selected accordingly. In the second step, the optimal values of design variables, flow rate, pH and sample loop volume, are obtained via multi-objective stochastic optimization. The strategy is applied to method development for the separation of 8, 12 and 16 component mixtures. It is shown that the proposed strategy provides an easy way to accelerate method development for full-comprehensive 2D-LC systems as it does not require any experimental campaign and an entire optimization run can take less than two minutes.
Collapse
Affiliation(s)
- Monica Tirapelle
- Department of Chemical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK
| | - Dian Ning Chia
- Department of Chemical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK
| | - Fanyi Duanmu
- Department of Chemical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK
| | - Maximilian O Besenhard
- Department of Chemical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK
| | - Luca Mazzei
- Department of Chemical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK
| | - Eva Sorensen
- Department of Chemical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK.
| |
Collapse
|
3
|
Muller M, Brau T, Lauer T, Stoll D, de Villiers A. Improving the Accuracy of Predictive 2D-LC Optimization Strategies: Incorporation of Simulated Elution Profiles to Account for Injection Band Broadening in Online Comprehensive Two-Dimensional Liquid Chromatography. Anal Chem 2024; 96:6398-6407. [PMID: 38593450 PMCID: PMC11044102 DOI: 10.1021/acs.analchem.4c00491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 03/25/2024] [Accepted: 03/27/2024] [Indexed: 04/11/2024]
Abstract
Method development in online comprehensive two-dimensional liquid chromatography (LC × LC) requires the selection of a large number of experimental parameters. The complexity of this process has led to several computer-based LC × LC optimization algorithms being developed to facilitate LC × LC method development. One particularly relevant challenge for predictive optimization software is to accurately model the effect of second dimension (2D) injection band broadening under sample solvent mismatch and/or sample volume overload conditions. We report a novel methodology that combines a chromatographic numerical simulation model capable of predicting elution profiles of analytes under conditions where peak distortion occurs with a predictive multiparameter Pareto optimization approach for online LC × LC. Preliminary method optimization is performed using a theoretical model to predict 2D injection profiles, and optimal experimental configurations obtained from the Pareto fronts are then subjected to further optimization using the simulation model. This approach drastically reduces the number of simulations and therefore the computational demand. We show that the optimal experimental conditions obtained in this manner are similar to those obtained using a complete optimization using only the simulation model. Online HILIC × RP-LC separation of phenolic compounds was used to compare experimental data to simulated two- and three-dimensional contour plots. The main advantage of the proposed approach is the ability to predict the formation of split or deformed peaks in the 2D, a significant benefit in online LC × LC method optimization, especially for separation combinations with mismatched mobile phases. A further benefit is that simulated elution profiles can be used for the visualization of predicted two-dimensional chromatograms for method selection.
Collapse
Affiliation(s)
- Magriet Muller
- Department
of Chemistry and Polymer Science, University
of Stellenbosch, Private Bag X1,
Matieland, Stellenbosch 7602, South Africa
| | - Tyler Brau
- Department
of Chemistry, Gustavus Adolphus College, 800 West College Avenue, Saint Peter, Minnesota 56082, United States
| | - Thomas Lauer
- Department
of Chemistry, Gustavus Adolphus College, 800 West College Avenue, Saint Peter, Minnesota 56082, United States
| | - Dwight Stoll
- Department
of Chemistry, Gustavus Adolphus College, 800 West College Avenue, Saint Peter, Minnesota 56082, United States
| | - André de Villiers
- Department
of Chemistry and Polymer Science, University
of Stellenbosch, Private Bag X1,
Matieland, Stellenbosch 7602, South Africa
| |
Collapse
|
4
|
Yeo J, Kang J, Kim H, Moon C. A Critical Overview of HPLC-MS-Based Lipidomics in Determining Triacylglycerol and Phospholipid in Foods. Foods 2023; 12:3177. [PMID: 37685110 PMCID: PMC10486615 DOI: 10.3390/foods12173177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Revised: 08/10/2023] [Accepted: 08/11/2023] [Indexed: 09/10/2023] Open
Abstract
With the current advancement in mass spectrometry (MS)-based lipidomics, the knowledge of lipidomes and their diverse roles has greatly increased, enabling a deeper understanding of the action of bioactive lipid molecules in plant- and animal-based foods. This review provides in-depth information on the practical use of MS techniques in lipidomics, including lipid extraction, adduct formation, MS analysis, data processing, statistical analysis, and bioinformatics. Moreover, this contribution demonstrates the effectiveness of MS-based lipidomics for identifying and quantifying diverse lipid species, especially triacylglycerols and phospholipids, in foods. Further, it summarizes the wide applications of MS-based lipidomics in food science, such as for assessing food processing methods, detecting food adulteration, and measuring lipid oxidation in foods. Thus, MS-based lipidomics may be a useful method for identifying the action of individual lipid species in foods.
Collapse
Affiliation(s)
- JuDong Yeo
- Department of Food Science and Biotechnology of Animal Resources, Konkuk University, Seoul 05029, Republic of Korea; (J.K.); (H.K.); (C.M.)
| | | | | | | |
Collapse
|
5
|
Rahmani T, Ampe A, Lynen F. Temperature Responsive × Fast Chiral Comprehensive Liquid Chromatography: a New 2D-LC Platform for Resolving Mixtures of Chiral Isomers. Anal Chem 2023. [PMID: 37262425 DOI: 10.1021/acs.analchem.3c00780] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Chiral resolution of solutes occurring in mixtures of unrelated species is of relevance in life sciences and in pharmaceutical analysis. While this is conceptually achievable by comprehensive two-dimensional liquid chromatography (LC × LC), few approaches exist whereby the second dimension comprises the chiral separation. The latter is preferable in combination with a conventional reversed phase type of separation in the first dimension as it offers an extension of a conventional achiral analysis. The implementation of such rapid chiral analyses in the second dimension was, thus far, limited by the challenging transfer of the first dimension mobile phase to the second dimension while still achieving chiral separation. In this study, the combination of temperature-responsive and reversed-phase chiral liquid chromatography is assessed in terms of enantioselective separation of a broad range of pharmaceutical compounds. Applying temperature-responsive liquid chromatography (TRLC) in the first dimension allows for analyses to be performed under purely aqueous conditions, which then allows for complete and more generic refocusing of (organic) solutes prior to the second dimension. This offers an enhanced ability to employ fast and broad compositional gradients over the chiral dimension, which broadens the applicability of the technique. In the proposed platform, seven chiral columns (superficially porous and fully porous columns (comprising both polysaccharide and macrocyclic antibiotic phases)) and four mobile phase gradients were screened on a pharmaceutical test mixture. The platform was shown to be able to offer the necessary resolving power for the molecules at hand and offers a new approach for chiral screening of mixtures of unrelated compounds.
Collapse
Affiliation(s)
- Turaj Rahmani
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Adriaan Ampe
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Frédéric Lynen
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| |
Collapse
|
6
|
Muller M, de Villiers A. A detailed evaluation of the advantages and limitations of online RP-LC×HILIC compared to HILIC×RP-LC for phenolic analysis. J Chromatogr A 2023; 1692:463843. [PMID: 36780845 DOI: 10.1016/j.chroma.2023.463843] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 01/20/2023] [Accepted: 01/30/2023] [Indexed: 02/05/2023]
Abstract
The combination of hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RP-LC) has proved effective in the LC × LC analysis of polyphenols due to the high degree of orthogonality associated with these separation modes for various classes of phenolic compounds. However, despite the growing number of such applications, HILIC is almost exclusively used as the first dimension (1D) separation mode, and RP-LC in the second dimension (2D). This is somewhat surprising in light of the potential advantages of swapping these separation modes. In this contribution, we present a detailed evaluation of the potential of online RP-LC × HILIC-MS for the analysis of phenolic compounds, comparing the performance of this system to the more established HILIC × RP-LC-MS configuration. Method development was performed using a predictive optimisation program, and fixed solvent modulation was employed to combat the solvent incompatibility between HILIC and RP-LC mobile phases. Red wine, rooibos tea, Protea and chestnut phenolic extracts containing a large diversity of phenolic compound classes were analysed by both HILIC × RP-LC- and RP-LC × HILIC-MS in order to compare the separation performance. Overall, the kinetic performance of HILIC × RP-LC was found to be clearly superior, with higher peak capacities and better resolution obtained for the majority of samples compared to RP-LC × HILIC analyses using similar column dimensions. Dilution of the 1D solvent combined with large volume injections proved insufficient to focus especially phenolic acids in the 2D HILIC separation, which resulted in severe 2D peak distortion for these compounds, and negatively impacted on method performance. On the other hand, a noteworthy improvement in the sensitivity of RP-LC × HILIC-MS analyses was observed due to higher ESI-MS response for the 2D HILIC mobile phase and greater sample loading capacity of the 1D RP-LC column, brought on by the high solubility of phenolic samples in aqueous solutions. As a result, a significantly higher number of compounds were detected in the RP-LC × HILIC-MS separations. These findings point to the potential advantage of RP-LC × HILIC as a complementary configuration to HILIC × RP-LC for phenolic analysis.
Collapse
Affiliation(s)
- Magriet Muller
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, Matieland, 7602, South Africa
| | - André de Villiers
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, Matieland, 7602, South Africa.
| |
Collapse
|
7
|
Enhancing the compatibility of normal-phase chromatography x reversed-phase chromatography by combination of low-temperature sensitive aqueous-phase compatible normal- phase chromatography and at-column dilution modulation. J Chromatogr A 2023; 1691:463821. [PMID: 36724722 DOI: 10.1016/j.chroma.2023.463821] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 01/19/2023] [Accepted: 01/21/2023] [Indexed: 01/27/2023]
Abstract
The nearly opposite retention mechanism in the two-dimensional liquid chromatography (2D-LC), which combines normal phase liquid chromatography (NPLC) and reversed phase liquid chromatography (RPLC), shows extremely high orthogonality and theoretical peak capacity. However, peak breakthrough and peak distortion caused by the highly incompatible 2D mobile phases counteracts the advantages offered by high orthogonality. To address this difficulty, this study proposes a comprehensive two-dimensional NPLC × RPLC integrating temperature-sensitive aqueous-phase compatible normal-phase chromatography (TSACNPLC) and at-column dilution modulation (ACDM). The proposed 2D-LC system uses an aqueous-miscible acetonitrile/methanol eluent in the 1st D NPLC, instead of an aqueous-phase immiscible eluent, such as n-hexane/methanol, to increase the miscibility with the RP mobile phase system. Additionally, the system exploits temperature-sensitive retention behavior to enhance the retention ability of aqueous-phase compatible NPLC. To verify the feasibility of the proposed 2D-LC, this study selected three multi-component samples with mid-to-low polarity, including ethoxylated (n ≈ 6) bisphenol A (BPA-6EO), ethoxylated (n ≈ 6) tristearylphenol (TSP-6EO), and safflower methanol extract. Next, the effectiveness of the constructed 2D-LC was systematically investigated, including low temperature-induced retention enhancement of NPLC, overcoming solvent incompatibility by ACDM, and optimization of 2 D separation conditions, was systematically investigated.
Collapse
|
8
|
Two-dimensional liquid chromatography-mass spectrometry for lipidomics using off-line coupling of hydrophilic interaction liquid chromatography with 50 cm long reversed phase capillary columns. J Chromatogr A 2023; 1687:463707. [PMID: 36516490 DOI: 10.1016/j.chroma.2022.463707] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 12/04/2022] [Accepted: 12/06/2022] [Indexed: 12/12/2022]
Abstract
Comprehensive characterization of the lipidome remains a challenge requiring development of new analytical approaches to expand lipid coverage in complex samples. In this work, offline two-dimensional liquid chromatography-mass spectrometry was investigated for lipidomics from human plasma. Hydrophilic interaction liquid chromatography was implemented in the first dimension to fractionate lipid classes. Nine fractions were collected and subjected to a second-dimension separation utilizing 50 cm capillary columns packed with 1.7 µm C18 particles operated on custom-built instrumentation at 35 kpsi. Online coupling with time-of-flight mass spectrometry allowed putative lipid identification from precursor-mass based library searching. The method had good orthogonality (fractional coverage of ∼40%), achieved a peak capacity of approximately 1900 in 600 min, and detected over 1000 lipids from a 5 µL injection of a human plasma extract while consuming less than 3 mL of solvent. The results demonstrate the expected gains in peak capacity when employing long columns and two-dimensional separations and illustrate practical approaches for improving lipidome coverage from complex biological samples.
Collapse
|
9
|
Using multiple heart-cutting valves and stop-flow operation to enable variable second dimension gradient times in online comprehensive two-dimensional liquid chromatography. J Chromatogr A 2022; 1685:463583. [DOI: 10.1016/j.chroma.2022.463583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 10/11/2022] [Accepted: 10/17/2022] [Indexed: 11/27/2022]
|
10
|
Wicht K, Baert M, Muller M, Bandini E, Schipperges S, von Doehren N, Desmet G, de Villiers A, Lynen F. Comprehensive two-dimensional temperature-responsive × reversed phase liquid chromatography for the analysis of wine phenolics. Talanta 2022; 236:122889. [PMID: 34635268 DOI: 10.1016/j.talanta.2021.122889] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 09/13/2021] [Accepted: 09/14/2021] [Indexed: 11/18/2022]
Abstract
Phenolic compounds are an interesting class of natural products because of their proposed contribution to health benefits of foods and beverages and as a bio-source of organic (aromatic) building blocks. Phenolic extracts from natural products are often highly complex and contain compounds covering a broad range in molecular properties. While many 1D-LC and mass spectrometric approaches have been proposed for the analysis of phenolics, this complexity inevitably leads to challenging identification and purification. New insights into the composition of phenolic extracts can be obtained through online comprehensive two-dimensional liquid chromatography (LC × LC) coupled to photodiode array and mass spectrometric detection. However, several practical hurdles must be overcome to achieve high peak capacities and to obtain robust methods with this technique. In many LC × LC configurations, refocusing of analytes at the head of the 2D column is hindered by the high eluotropic strength of the solvent transferred from the 1D to the 2D, leading to peak breakthrough or broadening. LC × LC combinations whereby a purely aqueous mobile phase is used in the 1D and RPLC is used in the 2D are unaffected by these phenomena, leading to more robust methods. In this contribution, the combination of temperature-responsive liquid chromatography (TRLC) with RPLC is used for the first time for the analysis of phenolic extracts of natural origin to illustrate the potential of this alternative combination for natural product analyses. The possibilities of the combination are investigated through analysis of wine extracts by TRLC × RPLC-DAD and TRLC × RPLC-ESI-MS.
Collapse
Affiliation(s)
- Kristina Wicht
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium
| | - Mathijs Baert
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium
| | - Magriet Muller
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, ZA-7602, Matieland, South Africa
| | - Elena Bandini
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium
| | - Sonja Schipperges
- Agilent Technologies, Hewlett Packard St 8, D-76337, Waldbronn, Germany
| | - Norwin von Doehren
- Agilent Technologies, Netherlands BV, NL-4330, EA, Middelburg, Netherlands
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, B-1050, Brussel, Belgium
| | - André de Villiers
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, ZA-7602, Matieland, South Africa
| | - Frederic Lynen
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium.
| |
Collapse
|
11
|
Chapel S, Heinisch S. Strategies to circumvent the solvent strength mismatch problem in online comprehensive two-dimensional liquid chromatography. J Sep Sci 2021; 45:7-26. [PMID: 34525266 DOI: 10.1002/jssc.202100534] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 08/23/2021] [Accepted: 08/24/2021] [Indexed: 11/09/2022]
Abstract
On-line comprehensive two-dimensional liquid chromatography is a powerful technique for the separation of highly complex samples. Due to the addition of the second dimension of separation, impressive peak capacities can be obtained within a reasonable analysis time compared to one-dimensional liquid chromatography. In online comprehensive two-dimensional liquid chromatography, the separation power is maximized by selecting two separation dimensions as orthogonal as possible, which most often requires the combination of different mobile phases and stationary phases. The online transfer of a given solvent from the first dimension to the second dimension may cause severe injection effects in the second dimension, mostly due to solvent strength mismatch. Those injection effects may include peak broadening, peak distortion, peak splitting or breakthrough phenomenon. They are often found to reduce significantly the peak capacity and the peak intensity. To overcome such effects, arising specifically in online comprehensive two-dimensional liquid chromatography, different methods have been developed over the years. In this review, we focused on the most recently reported ones. A critical discussion, supported by a theoretical approach, gives an overview of their advantages and drawbacks.
Collapse
Affiliation(s)
- Soraya Chapel
- Université de Lyon, Institut des sciences analytiques, Villeurbanne, France
| | - Sabine Heinisch
- Université de Lyon, Institut des sciences analytiques, Villeurbanne, France
| |
Collapse
|
12
|
Lecas L, Nuccio S, de Vaumas R, Faure K. Off-line two-dimensional liquid chromatography separation for the quality control of saponins samples from Quillaja Saponaria. J Sep Sci 2021; 44:3070-3079. [PMID: 34165880 DOI: 10.1002/jssc.202100115] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 05/18/2021] [Accepted: 06/16/2021] [Indexed: 11/05/2022]
Abstract
Quil-A is a purified extract of saponins with strong immunoadjuvant activity. While specific molecules have been identified and tested in clinical trials, Quil-A is mostly used as a totum of the Quillaja Saponaria bark extract. Quality control of the extract stability is usually based on the monitoring of specific saponins, whereas the comparison of samples with an initial chromatogram seems more appropriate. A reference fingerprint based on comprehensive two-dimensional liquid chromatography offers a rapid detection of nonconform samples. To fulfill quality control constraints, off-line configuration using basic instrumentation was promoted. Hence, reversed-phase liquid chromatography × reversed-phase liquid chromatography and hydrophilic interaction chromatography × reversed-phase liquid chromatography methods with ultraviolet and single-quadrupole mass spectrometry detection were kinetically optimized. The reversed-phase liquid chromatography × reversed-phase liquid chromatography method used a pH switch between dimensions to maximize orthogonality. Despite diagonalization, it led to a high peak capacity of 831 in 2 h. On the other hand, the combination of hydrophilic interaction chromatography and reversed-phase liquid chromatography offered a larger orthogonality but a lower, yet satisfactory peak capacity of 673. The advantages of both methods were illustrated on degraded samples, where the reversed-phase liquid chromatography × reversed-phase liquid chromatography contour plot highlighted the loss of fatty acid chains, while the hydrophilic interaction chromatography × reversed-phase liquid chromatography method was found useful to evidence enzymatic loss of sugar moieties.
Collapse
Affiliation(s)
- Lucile Lecas
- Institut des Sciences Analytiques, Université de Lyon, CNRS, Université Claude Bernard Lyon 1, Villeurbanne, F-69100, France.,Extrasynthese, Impasse Jacquard, Genay, F-69730, France
| | - Sylvie Nuccio
- Extrasynthese, Impasse Jacquard, Genay, F-69730, France
| | | | - Karine Faure
- Institut des Sciences Analytiques, Université de Lyon, CNRS, Université Claude Bernard Lyon 1, Villeurbanne, F-69100, France
| |
Collapse
|
13
|
Walters NA, de Beer D, de Villiers A, Danton O, Hamburger M, Joubert E. Comprehensive off-line CCC × LC-DAD-MS separation of Cyclopia pubescens Eckl. & Zeyh. phenolic compounds and structural elucidation of isolated compounds. PHYTOCHEMICAL ANALYSIS : PCA 2021; 32:347-361. [PMID: 32803806 DOI: 10.1002/pca.2981] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 07/27/2020] [Accepted: 07/28/2020] [Indexed: 06/11/2023]
Abstract
INTRODUCTION The minor phenolic constituents of Cyclopia pubescens Eckl. & Zeyh. are unknown and one dimensional (1D) liquid chromatography (LC) is unable to provide sufficient separation. METHODOLOGY A two-dimensional (2D) LC method incorporating normal-phasehigh performance countercurrent chromatography (NP-HPCCC) in the first dimension (1 D) and reversed-phase ultra-high-performance liquid chromatography (RP-UHPLC) as the second dimension (2 D) was developed. The analytical HPCCC method was subsequently scaled up to semi-preparative mode and fractions pooled based on phenolic sub-groups. The phenolic compounds in selected fractions were subsequently isolated using RP-HPLC on a C18 column. Isolated compounds were identified by nuclear magnetic resonance (NMR) spectroscopy. The absolute configurations of compounds were determined by optical rotation and electronic circular dichroism spectra. Sugars were identified by gas chromatography-mass spectrometry (GC-MS) analysis. RESULTS The comprehensive off-line 2D CCC × LC method gave a good spread of the phenolic compounds. Orthogonality calculated using both the convex hull and conditional entropy methods were 81%. High-resolution mass spectrometric fragmentation spectra obtained from a quadrupole-time-of-flight instrument and ultraviolet-visible (UV-vis) spectral data were used to (tentatively) identify 32 phenolic compounds from the analytical CCC fractions. Of the seven isolated compounds, (2S)-5-O-[α-l-rhamnopyranosyl-(1 → 2)-β-d-glucopyranosyl]eriodictyol (3) and (2S)-5-O-[α-l-rhamnopyranosyl-(1 → 2)-β-d-glucopyranosyl]-5,7,3',4'-tetrahydroxyflavan (4) were newly identified in all plants. The other isolated compounds were identified as (2S)-5-O-[α-l-rhamnopyranosyl-(1 → 2)-β-d-glucopyranosyl]naringenin (1), R-neo-eriocitrin (2), 3-O-α-l-arabinopyranosyl-3,4-dihydroxybenzoic acid (5), 4-O-β-d-glucopyranosyl-Z-4-hydroxycinnamic acid (6) and 4-(4'-O-β-d-glucopyranosyl-4'-hydroxy-3'-methoxyphenyl)-2-butanone (7). CONCLUSIONS Among the 32 compounds (tentatively) identified, only six were previously identified in Cyclopia pubescens using 1D LC. Most of the isolated compounds were also identified for the first time in Cyclopia spp., improving the knowledge of the minor phenolic compounds of this genus.
Collapse
Affiliation(s)
- Nico A Walters
- Plant Bioactives Group, Post-Harvest & Agro-Processing Technologies, Agricultural Research Council (ARC), Infruitec-Nietvoorbij, Stellenbosch, South Africa
- Department of Food Science, Stellenbosch University, Stellenbosch, South Africa
| | - Dalene de Beer
- Plant Bioactives Group, Post-Harvest & Agro-Processing Technologies, Agricultural Research Council (ARC), Infruitec-Nietvoorbij, Stellenbosch, South Africa
- Department of Food Science, Stellenbosch University, Stellenbosch, South Africa
| | - André de Villiers
- Department of Chemistry and Polymer Science, Stellenbosch University, Stellenbosch, South Africa
| | - Ombeline Danton
- Pharmaceutical Biology, Pharmacenter, University of Basel, Basel, Switzerland
| | - Matthias Hamburger
- Pharmaceutical Biology, Pharmacenter, University of Basel, Basel, Switzerland
| | - Elizabeth Joubert
- Plant Bioactives Group, Post-Harvest & Agro-Processing Technologies, Agricultural Research Council (ARC), Infruitec-Nietvoorbij, Stellenbosch, South Africa
- Department of Food Science, Stellenbosch University, Stellenbosch, South Africa
| |
Collapse
|
14
|
Pérez-Cova M, Jaumot J, Tauler R. Untangling comprehensive two-dimensional liquid chromatography data sets using regions of interest and multivariate curve resolution approaches. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116207] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
15
|
Cacciola F, Arena K, Mandolfino F, Donnarumma D, Dugo P, Mondello L. Reversed phase versus hydrophilic interaction liquid chromatography as first dimension of comprehensive two-dimensional liquid chromatography systems for the elucidation of the polyphenolic content of food and natural products. J Chromatogr A 2021; 1645:462129. [PMID: 33864987 DOI: 10.1016/j.chroma.2021.462129] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 03/22/2021] [Accepted: 03/25/2021] [Indexed: 12/19/2022]
Abstract
Comprehensive two-dimensional liquid chromatography is a well-established method for the unraveling of very complex real-world samples. With regard to food and natural products such a technique turned out to be a very promising approach due to its high resolving power and improved identification capability, especially in combination with mass spectrometry. In this context, polyphenols comprise a particular complex class of bioactive compounds, due to their nature and content in commonly consumed foodstuffs, making their analysis challenging. The present contribution shows an overview of the two commonly employed approaches used for polyphenol analysis, viz. RP-LC × RP-LC and HILIC × RP-LC. Furthermore, the latest implementations as well as limitations and future perspectives are critically reported.
Collapse
Affiliation(s)
- Francesco Cacciola
- Department of Biomedical, Dental, Morphological and Functional Imaging Sciences, University of Messina, 98125 Messina, Italy.
| | - Katia Arena
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy
| | - Filippo Mandolfino
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy
| | - Danilo Donnarumma
- Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy
| | - Paola Dugo
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy; Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy
| | - Luigi Mondello
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy; Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy; Department of Sciences and Technologies for Human and Environment, University Campus Bio-Medico of Rome, 00128 Rome, Italy; BeSep s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy
| |
Collapse
|
16
|
Cacciola F, Rigano F, Dugo P, Mondello L. Comprehensive two-dimensional liquid chromatography as a powerful tool for the analysis of food and food products. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115894] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
17
|
Jandera P, Hájek T. Dual‐mode hydrophilic interaction normal phase and reversed phase liquid chromatography of polar compounds on a single column. J Sep Sci 2019; 43:70-86. [DOI: 10.1002/jssc.201900920] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Revised: 10/11/2019] [Accepted: 10/15/2019] [Indexed: 12/11/2022]
Affiliation(s)
- Pavel Jandera
- Department of Analytical ChemistryUniversity of Pardubice Pardubice Czech Republic
| | - Tomáš Hájek
- Department of Analytical ChemistryUniversity of Pardubice Pardubice Czech Republic
| |
Collapse
|
18
|
Zou YC, Wu CL, Ma CF, He S, Brennan CS, Yuan Y. Interactions of grape seed procyanidins with soy protein isolate: Contributing antioxidant and stability properties. Lebensm Wiss Technol 2019. [DOI: 10.1016/j.lwt.2019.108465] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
19
|
Bernardin M, Masle AL, Bessueille-Barbier F, Lienemann CP, Heinisch S. Comprehensive two-dimensional liquid chromatography with inductively coupled plasma mass spectrometry detection for the characterization of sulfur, vanadium and nickel compounds in petroleum products. J Chromatogr A 2019; 1611:460605. [PMID: 31662186 DOI: 10.1016/j.chroma.2019.460605] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 09/30/2019] [Accepted: 10/06/2019] [Indexed: 12/16/2022]
Abstract
The petroleum industry is increasingly concerned with the conversion of vacuum residues as a consequence of decreased conventional crude oil availability. The compositional analysis of heavy oil products has become a key step in conversion processes, but the complexity of these oil matrices tends to increase with their boiling point. In this study, comprehensive two-dimensional liquid chromatography (LCxLC) coupled to inductively coupled mass spectrometry (ICP-MS/MS) is considered with a view to meet new requirements and to bring additional information regarding the species present in these matrices. In search for a high degree of orthogonality, two separation techniques involving two different retention mechanisms were evaluated: Size Exclusion Chromatography (SEC) and Reverse Phase Liquid Chromatography (RPLC). In SEC, the analytes are separated according to their molecular weight while according to their hydrophobicity in RPLC. The separation power of both individual separation techniques was first evaluated. Off-line and on-line LCxLC were compared on the basis of an optimization approach. It is shown that off-line SECxRPLC can provide, for the same analysis time of 150 min, a higher peak capacity (2600 vs 1700) than on-line RPLCxSEC while a similar dilution factor (close to 30) but also requires far fewer fractions to be analyzed (12 vs 400). Asphaltenes which constitute the heaviest fraction of crude oils (obtained from petroleum industry) were analyzed by the developed off-line SECxRPLC method. The resulting 2D-contour plots show that co-elutions could be removed leading, for the first time, to new information on high molecular weight species containing sulfur and vanadium.
Collapse
Affiliation(s)
- Marie Bernardin
- Université de Lyon, Institut des Sciences Analytiques, UMR 5280, CNRS, 5 rue de la Doua, 69100 Villeurbanne, France; IFP Energies nouvelles, Rond-point de l'échangeur de Solaize, BP 3, 69360 Solaize France
| | - Agnès Le Masle
- IFP Energies nouvelles, Rond-point de l'échangeur de Solaize, BP 3, 69360 Solaize France
| | | | | | - Sabine Heinisch
- Université de Lyon, Institut des Sciences Analytiques, UMR 5280, CNRS, 5 rue de la Doua, 69100 Villeurbanne, France.
| |
Collapse
|
20
|
Marques TL, Nóbrega JA, Rocha FR. Flow-based solid sample preparation: Advantages, limitations, and challenges. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.07.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
21
|
Cavaliere C, Capriotti AL, La Barbera G, Montone CM, Piovesana S, Laganà A. Liquid Chromatographic Strategies for Separation of Bioactive Compounds in Food Matrices. Molecules 2018; 23:E3091. [PMID: 30486380 PMCID: PMC6320936 DOI: 10.3390/molecules23123091] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2018] [Revised: 10/31/2018] [Accepted: 11/21/2018] [Indexed: 11/19/2022] Open
Abstract
Nowadays, there is an increasing attention for nutraceuticals and, in general, bioactive compounds naturally present in food. Indeed, the possibility of preserving human health and preventing disease (e.g., cardiovascular diseases, cancer etc.) by the intake of healthy food is attractive for both consumers and food industries. In turn, research in this field was also prompted significantly, with the aim of characterizing these bioactive compounds and ascribe to them a specific activity. The bioactive compounds can belong to several chemical classes. However, their chemical diversity and presence in complex matrices, such as food, make it challenging both their isolation and characterization. To tackle this issue, efficient separation systems are needed, which are mainly based on chromatography. In this context, this mini-review aims to provide the reader with an overview of the most relevant and recent approaches for the separation of the most common bioactive compounds in food, in particular polyphenols, phenols, carotenoids, and peptides, by liquid chromatography approaches.
Collapse
Affiliation(s)
- Chiara Cavaliere
- Department of Chemistry, Sapienza University of Rome, Piazzale Aldo Moro, 00185 Roma, Italy.
| | - Anna Laura Capriotti
- Department of Chemistry, Sapienza University of Rome, Piazzale Aldo Moro, 00185 Roma, Italy.
| | - Giorgia La Barbera
- Department of Chemistry, Sapienza University of Rome, Piazzale Aldo Moro, 00185 Roma, Italy.
| | - Carmela Maria Montone
- Department of Chemistry, Sapienza University of Rome, Piazzale Aldo Moro, 00185 Roma, Italy.
| | - Susy Piovesana
- Department of Chemistry, Sapienza University of Rome, Piazzale Aldo Moro, 00185 Roma, Italy.
| | - Aldo Laganà
- Department of Chemistry, Sapienza University of Rome, Piazzale Aldo Moro, 00185 Roma, Italy.
| |
Collapse
|
22
|
Muller M, Tredoux AGJ, de Villiers A. Application of Kinetically Optimised Online HILIC × RP-LC Methods Hyphenated to High Resolution MS for the Analysis of Natural Phenolics. Chromatographia 2018. [DOI: 10.1007/s10337-018-3662-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
23
|
Predictive kinetic optimisation of hydrophilic interaction chromatography × reversed phase liquid chromatography separations: Experimental verification and application to phenolic analysis. J Chromatogr A 2018; 1571:107-120. [DOI: 10.1016/j.chroma.2018.08.004] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Revised: 07/25/2018] [Accepted: 08/01/2018] [Indexed: 01/26/2023]
|
24
|
Tuominen A, Karonen M. Variability between organs of proanthocyanidins in Geranium sylvaticum analyzed by off-line 2-dimensional HPLC-MS. PHYTOCHEMISTRY 2018; 150:106-117. [PMID: 29579735 DOI: 10.1016/j.phytochem.2018.03.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2017] [Revised: 03/05/2018] [Accepted: 03/06/2018] [Indexed: 06/08/2023]
Abstract
Proanthocyanidins have been characterized in the different organs of Geranium sylvaticum by using an off-line 2-dimensional chromatographic method. In the first dimension, proanthocyanidins were separated according to their increasing degree of polymerization by hydrophilic interaction liquid chromatography. In the second dimension, reversed-phase liquid chromatography was used to separate the same size isomers based on their hydrophobicity. Ultraviolet detection and high-resolution electrospray ionization time-of-flight mass spectrometry were used for the identification and characterization of proanthocyanidins. The method was proven to be suitable for the analysis of plant organ fractions of G. sylvaticum that contained complex mixtures of phenolic compounds and proanthocyanidins from several classes. Procyanidins, prodelphinidins and mixed proanthocyanidins composed of both (epi)catechin and (epi)gallocatechin units including monomers, oligomers and polymers up to the degree of polymerization of 20 were identified. The type and size of proanthocyanidins varied between eight studied organs of G. sylvaticum. The 2-dimensional analysis revealed that each proanthocyanidin type occur in the equally complex isomeric pattern. The mean degree of polymerization of different proanthocyanidins in the eight plant organs of G. sylvaticum was 5 and it varied only slightly between plant organs.
Collapse
Affiliation(s)
- Anu Tuominen
- Natural Chemistry Research Group, Department of Chemistry, University of Turku, FI-20014 Turku, Finland.
| | - Maarit Karonen
- Natural Chemistry Research Group, Department of Chemistry, University of Turku, FI-20014 Turku, Finland
| |
Collapse
|
25
|
Toro-Uribe S, López-Giraldo LJ, Decker EA. Relationship between the Physiochemical Properties of Cocoa Procyanidins and Their Ability to Inhibit Lipid Oxidation in Liposomes. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2018; 66:4490-4502. [PMID: 29649362 DOI: 10.1021/acs.jafc.8b01074] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The aim of this paper is to evaluate the effects of cocoa polyphenols and procyanidins with different degrees of polymerization that are encapsulated in liposome delivery systems on the inhibition of lipid oxidation at pH 3.0 and 5.0. In general, liposomes at pH 3.0 and 5.0 were physically stable in the presence of polyphenols and procyanidins with mean particle sizes of 56.56 ± 12.29 and 77.45 ± 8.67 nm and ζ-potentials of -33.50 ± 3.16 and -20.44 ± 1.98 mV at pH 3.0 and 5.0, respectively. At both pH 3.0 and pH 5.0, all the polyphenols and procyanidins inhibited lipid hydroperoxide and hexanal formation, and antioxidant activities increased with increasing polymer-chain sizes. The greater antioxidant activities of the isolated procyanidins were likely due to their increased metal-chelating capacities, as determined by ferric-reducing-ability (FRAP) assays, and their greater levels of partitioning into the lipids, as determined by their log Kow values and encapsulation efficiencies. The crude extract had the greatest antioxidant activity, which could be because other antioxidants were present, or combinations of the different polyphenols and procyanidins inhibited lipid oxidation synergistically.
Collapse
Affiliation(s)
- Said Toro-Uribe
- Food Science & Technology Research Center (CICTA), School of Chemical Engineering , Universidad Industrial de Santander , Carrera 27, Calle 9 , Bucaramanga 680002 , Colombia
| | - Luis J López-Giraldo
- Food Science & Technology Research Center (CICTA), School of Chemical Engineering , Universidad Industrial de Santander , Carrera 27, Calle 9 , Bucaramanga 680002 , Colombia
| | - Eric A Decker
- Department of Food Science , University of Massachusetts , Chenoweth Laboratory, 102 Holdsworth Way , Amherst , Massachusetts 01003 , United States
| |
Collapse
|
26
|
Stoll DR, Harmes DC, Staples GO, Potter OG, Dammann CT, Guillarme D, Beck A. Development of Comprehensive Online Two-Dimensional Liquid Chromatography/Mass Spectrometry Using Hydrophilic Interaction and Reversed-Phase Separations for Rapid and Deep Profiling of Therapeutic Antibodies. Anal Chem 2018; 90:5923-5929. [DOI: 10.1021/acs.analchem.8b00776] [Citation(s) in RCA: 58] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Dwight R. Stoll
- Department of Chemistry, Gustavus Adolphus College, St. Peter, Minnesota 56082, United States
| | - David C. Harmes
- Department of Chemistry, Gustavus Adolphus College, St. Peter, Minnesota 56082, United States
| | | | - Oscar G. Potter
- Agilent Technologies, Santa Clara, California 95051, United States
| | - Carston T. Dammann
- Department of Chemistry, Gustavus Adolphus College, St. Peter, Minnesota 56082, United States
| | - Davy Guillarme
- School of Pharmaceutical
Sciences, University of Geneva and University of Lausanne, Rue Michel Servet 1, 1206 Geneva 4, Switzerland
| | - Alain Beck
- Institut de Recherche Pierre Fabre, Center of Immunology, Pierre Fabre, 5, Avenue Napoléon III, BP 60497, 74160 Saint-Julien-en-Genevois, France
| |
Collapse
|
27
|
Baert M, Martens S, Desmet G, de Villiers A, Du Prez F, Lynen F. Enhancing the Possibilities of Comprehensive Two-Dimensional Liquid Chromatography through Hyphenation of Purely Aqueous Temperature-Responsive and Reversed-Phase Liquid Chromatography. Anal Chem 2018; 90:4961-4967. [PMID: 29551061 DOI: 10.1021/acs.analchem.7b04914] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Comprehensive two-dimensional liquid chromatography (LC × LC) allows for substantial gains in theoretical peak capacity in the field of liquid chromatography. However, in practice, theoretical performance is rarely achieved due to a combination of undersampling, orthogonality, and refocusing issues prevalent in many LC × LC applications. This is intricately linked to the column dimensions, flow rates, and mobile-phase compositions used, where, in many cases, incompatible or strong solvents are introduced in the second-dimension (2D) column, leading to peak broadening and the need for more complex interfacing approaches. In this contribution, the combination of temperature-responsive (TR) and reversed-phase (RP) LC is demonstrated, which, due to the purely aqueous mobile phase used in TRLC, allows for complete and more generic refocusing of organic solutes prior to the second-dimension RP separation using a conventional 10-port valve interface. Thus far, this was only possible when combining other purely aqueous modes such as ion exchange or gel filtration chromatography with RPLC, techniques which are limited to the analysis of charged or high MW solutes, respectively. This novel TRLC × RPLC combination relaxes undersampling constraints and complete refocusing and therefore offers novel possibilities in the field of LC × LC including temperature modulation. The concept is illustrated through the TRLC × RPLC analysis of mixtures of neutral organic solutes.
Collapse
Affiliation(s)
| | | | - Gert Desmet
- Department of Chemical Engineering , Vrije Universiteit Brussel , Pleinlaan 2 , 1050 Brussel , Belgium
| | - André de Villiers
- Department of Chemistry and Polymer Science , Stellenbosch University , Private Bag X1 , Matieland, Stellenbosch 7602 , South Africa
| | | | | |
Collapse
|
28
|
Xu J, Zheng L, Lin L, Sun B, Su G, Zhao M. Stop-flow reversed phase liquid chromatography × size-exclusion chromatography for separation of peptides. Anal Chim Acta 2018; 1018:119-126. [PMID: 29605129 DOI: 10.1016/j.aca.2018.02.025] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Revised: 02/07/2018] [Accepted: 02/13/2018] [Indexed: 01/14/2023]
Abstract
Size-exclusion chromatography (SEC) with wide application in peptide analysis presents challenges in determination of molecular weight distribution due to the relatively low resolution. In this study, a stop-flow reversed phase liquid chromatography (RPLC) × SEC system was constructed, aiming at improving the peptide separation in SEC. As the chromatographic dispersion during stop-flow operation might contribute to the band broadening in the first dimension (1st D) RPLC, the effects of different stop-flow operational parameters on the additional band broadening were quantitatively evaluated. Unlike analytes of large molecular size or long retention time with low effective diffusion coefficient (Deff), additional band broadening was evidently observed for analytes of small molecular size and short retention time (high Deff). Therefore, optimal flow rate, low column temperature and short stop-flow time were suggested for analyzing small molecules of short retention time. The established stop-flow two-dimensional liquid chromatography (2D-LC) was further tested on protein hydrolysates. The resolution was evidently improved for both heart-cutting and comprehensive 2D-LC analysis (despite additional band broadening in RPLC). Compared with heart-cutting analysis with higher 1st D resolution for selective fractions, comprehensive analysis could provide more complete information about the molecular weight distribution of the eluting solutes along RPLC.
Collapse
Affiliation(s)
- Jucai Xu
- School of Food Science and Engineering, South China University of Technology, Guangzhou, 510640, China; Guangdong Food Green Processing and Nutrition Regulation Technologies Research Center, Guangzhou, 510640, China
| | - Lin Zheng
- School of Food Science and Engineering, South China University of Technology, Guangzhou, 510640, China; Guangdong Food Green Processing and Nutrition Regulation Technologies Research Center, Guangzhou, 510640, China
| | - Lianzhu Lin
- School of Food Science and Engineering, South China University of Technology, Guangzhou, 510640, China; Guangdong Food Green Processing and Nutrition Regulation Technologies Research Center, Guangzhou, 510640, China
| | - Baoguo Sun
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology & Business University, Beijing, 100048, China
| | - Guowan Su
- School of Food Science and Engineering, South China University of Technology, Guangzhou, 510640, China; Guangdong Food Green Processing and Nutrition Regulation Technologies Research Center, Guangzhou, 510640, China.
| | - Mouming Zhao
- School of Food Science and Engineering, South China University of Technology, Guangzhou, 510640, China; Guangdong Food Green Processing and Nutrition Regulation Technologies Research Center, Guangzhou, 510640, China; Beijing Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology & Business University, Beijing, 100048, China.
| |
Collapse
|
29
|
Jandera P, Hájek T. Mobile phase effects on the retention on polar columns with special attention to the dual hydrophilic interaction-reversed-phase liquid chromatography mechanism, a review. J Sep Sci 2017; 41:145-162. [DOI: 10.1002/jssc.201701010] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Revised: 10/04/2017] [Accepted: 10/04/2017] [Indexed: 11/11/2022]
Affiliation(s)
- Pavel Jandera
- Department of Analytical Chemistry; Faculty of Chemical Technology; University of Pardubice; Pardubice Czech Republic
| | - Tomáš Hájek
- Department of Analytical Chemistry; Faculty of Chemical Technology; University of Pardubice; Pardubice Czech Republic
| |
Collapse
|
30
|
|
31
|
Additional band broadening of peptides in the first size-exclusion chromatographic dimension of an automated stop-flow two-dimensional high performance liquid chromatography. J Chromatogr A 2017; 1521:80-89. [DOI: 10.1016/j.chroma.2017.09.025] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2017] [Revised: 08/22/2017] [Accepted: 09/08/2017] [Indexed: 12/14/2022]
|
32
|
Ranjbar L, Talebi M, Haddad PR, Park SH, Cabot JM, Zhang M, Smejkal P, Foley JP, Breadmore MC. In Silico Screening of Two-Dimensional Separation Selectivity for Ion Chromatography × Capillary Electrophoresis Separation of Low-Molecular-Mass Organic Acids. Anal Chem 2017; 89:8808-8815. [DOI: 10.1021/acs.analchem.7b01187] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Leila Ranjbar
- Australian
Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Mohammad Talebi
- Australian
Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Paul R. Haddad
- Australian
Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Soo Hyun Park
- Australian
Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Joan M. Cabot
- Australian
Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
- ARC
Centre of Excellence for Electromaterials Science, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Min Zhang
- Australian
Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Petr Smejkal
- Australian
Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Joe P. Foley
- Australian
Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
- Department
of Chemistry, Drexel University, Philadelphia, Pennsylvania 19104, United States
| | - Michael C. Breadmore
- Australian
Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| |
Collapse
|
33
|
Jandera P, Janás P. Recent advances in stationary phases and understanding of retention in hydrophilic interaction chromatography. A review. Anal Chim Acta 2017; 967:12-32. [DOI: 10.1016/j.aca.2017.01.060] [Citation(s) in RCA: 180] [Impact Index Per Article: 25.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2016] [Revised: 01/05/2017] [Accepted: 01/06/2017] [Indexed: 12/01/2022]
|
34
|
Walters NA, de Villiers A, Joubert E, de Beer D. Phenolic profiling of rooibos using off-line comprehensive normal phase countercurrent chromatography × reversed phase liquid chromatography. J Chromatogr A 2017; 1490:102-114. [DOI: 10.1016/j.chroma.2017.02.021] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Revised: 02/06/2017] [Accepted: 02/11/2017] [Indexed: 01/17/2023]
|
35
|
Affiliation(s)
- Dwight R. Stoll
- Department
of Chemistry, Gustavus Adolphus College, Saint Peter, Minnesota 56082, United States
| | - Peter W. Carr
- Department
of Chemistry, University of Minnesota, Minneapolis, Minnesota 55104, United States
| |
Collapse
|
36
|
Cacciola F, Donato P, Sciarrone D, Dugo P, Mondello L. Comprehensive Liquid Chromatography and Other Liquid-Based Comprehensive Techniques Coupled to Mass Spectrometry in Food Analysis. Anal Chem 2016; 89:414-429. [DOI: 10.1021/acs.analchem.6b04370] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- Francesco Cacciola
- Dipartimento
di Scienze Biomediche, Odontoiatriche e delle Immagini Morfologiche
e Funzionali, University of Messina, Via Consolare Valeria, 98125 Messina, Italy
| | - Paola Donato
- Dipartimento
di Scienze Biomediche, Odontoiatriche e delle Immagini Morfologiche
e Funzionali, University of Messina, Via Consolare Valeria, 98125 Messina, Italy
| | - Danilo Sciarrone
- Dipartimento
di Scienze Chimiche, Biologiche, Farmaceutiche ed Ambientali, University of Messina, Polo Annunziata, Viale Annunziata, 98168 Messina, Italy
| | - Paola Dugo
- Dipartimento
di Scienze Chimiche, Biologiche, Farmaceutiche ed Ambientali, University of Messina, Polo Annunziata, Viale Annunziata, 98168 Messina, Italy
- Unit
of Food Science and Nutrition, Department of Medicine, University Campus Bio-Medico of Rome, Via Alvaro del Portillo 21, 00128 Rome, Italy
- Chromaleont
s.r.l., c/o Dipartimento di Scienze Chimiche, Biologiche, Farmaceutiche
ed Ambientali, University of Messina, Polo Annunziata, Viale Annunziata, 98168 Messina, Italy
| | - Luigi Mondello
- Dipartimento
di Scienze Chimiche, Biologiche, Farmaceutiche ed Ambientali, University of Messina, Polo Annunziata, Viale Annunziata, 98168 Messina, Italy
- Unit
of Food Science and Nutrition, Department of Medicine, University Campus Bio-Medico of Rome, Via Alvaro del Portillo 21, 00128 Rome, Italy
- Chromaleont
s.r.l., c/o Dipartimento di Scienze Chimiche, Biologiche, Farmaceutiche
ed Ambientali, University of Messina, Polo Annunziata, Viale Annunziata, 98168 Messina, Italy
| |
Collapse
|
37
|
Cacciola F, Farnetti S, Dugo P, Marriott PJ, Mondello L. Comprehensive two-dimensional liquid chromatography for polyphenol analysis in foodstuffs. J Sep Sci 2016; 40:7-24. [DOI: 10.1002/jssc.201600704] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2016] [Revised: 07/28/2016] [Accepted: 07/29/2016] [Indexed: 12/18/2022]
Affiliation(s)
- Francesco Cacciola
- Dipartimento di “Scienze Biomediche, Odontoiatriche e delle Immagini Morfologiche e Funzionali,”; University of Messina; Messina Italy
| | - Sara Farnetti
- Diabetes Research Institute, Division of Cellular Transplantation of Surgery; University of Miami; Miami FL USA
| | - Paola Dugo
- Dipartimento di “Scienze Chimiche, Biologiche, Farmaceutiche ed Ambientali; University of Messina; Messina Italy
- Chromaleont S.r.L; Viale Boccetta 70 98122 Messina Italy
- Unit of Food Science and Nutrition, Department of Medicine; University Campus Bio-Medico of Rome; Rome Italy
| | - Philip John Marriott
- Australian Centre of Research on Separation Science, School of Chemistry; Monash University; Clayton Australia
| | - Luigi Mondello
- Dipartimento di “Scienze Chimiche, Biologiche, Farmaceutiche ed Ambientali; University of Messina; Messina Italy
- Chromaleont S.r.L; Viale Boccetta 70 98122 Messina Italy
- Unit of Food Science and Nutrition, Department of Medicine; University Campus Bio-Medico of Rome; Rome Italy
| |
Collapse
|
38
|
Pirok BW, Pous-Torres S, Ortiz-Bolsico C, Vivó-Truyols G, Schoenmakers PJ. Program for the interpretive optimization of two-dimensional resolution. J Chromatogr A 2016; 1450:29-37. [DOI: 10.1016/j.chroma.2016.04.061] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Revised: 04/20/2016] [Accepted: 04/21/2016] [Indexed: 11/29/2022]
|
39
|
de Villiers A, Venter P, Pasch H. Recent advances and trends in the liquid-chromatography–mass spectrometry analysis of flavonoids. J Chromatogr A 2016; 1430:16-78. [DOI: 10.1016/j.chroma.2015.11.077] [Citation(s) in RCA: 105] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2015] [Accepted: 11/25/2015] [Indexed: 12/22/2022]
|
40
|
Sun W, Tong L, Miao J, Huang J, Li D, Li Y, Xiao H, Sun H, Bi K. Separation and analysis of phenolic acids from Salvia miltiorrhiza and its related preparations by off-line two-dimensional hydrophilic interaction chromatography × reversed-phase liquid chromatography coupled with ion trap time-of-flight mass spectrometry. J Chromatogr A 2016; 1431:79-88. [DOI: 10.1016/j.chroma.2015.12.038] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Revised: 12/13/2015] [Accepted: 12/15/2015] [Indexed: 12/01/2022]
|
41
|
Abstract
This article summarizes the most important developments in the use of 2D-LC for bioanalysis in the last 5 years. While several interesting and powerful applications have been developed recently, this work has been supported by continued, significant development of theoretical concepts, instrument development and practical aspects of method development. Some of the most exciting applications have been focused on the use of 2D-LC and characterize proteins both as biotherapeutic drug substances, and in formulations. These materials are inherently complex, difficult to resolve chromatographically and present problems that are essentially unknown (e.g., aggregation) in the small molecule world, thus 2D-LC can be leveraged very effectively to address these challenges.
Collapse
|
42
|
Willemse CM, Stander MA, Vestner J, Tredoux AGJ, de Villiers A. Comprehensive Two-Dimensional Hydrophilic Interaction Chromatography (HILIC) × Reversed-Phase Liquid Chromatography Coupled to High-Resolution Mass Spectrometry (RP-LC-UV-MS) Analysis of Anthocyanins and Derived Pigments in Red Wine. Anal Chem 2015; 87:12006-15. [DOI: 10.1021/acs.analchem.5b03615] [Citation(s) in RCA: 64] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Chandré M. Willemse
- Department
of Chemistry and Polymer Science, Stellenbosch University, Private Bag
X1, Matieland 7602, South Africa
| | - Maria A. Stander
- Central
Analytical Facility, Stellenbosch University, Private Bag X1, Matieland 7602, South Africa
- Department
of Biochemistry, Stellenbosch University, Private Bag X1, Matieland 7602, South Africa
| | - Jochen Vestner
- Center
of Analytical Chemistry and Microbiology, Department of Microbiology
and Biochemistry, Hochschule Geisenheim University, 65366 Geisenheim, Germany
- Université
de Bordeaux, ISVV, EA 4577, Unité de recherche
Œnologie, 33882 Villenave d’Ornon, France
- INRA, ISVV, USC 1366 Œnologie, 33882 Villenave d’Ornon, France
| | - Andreas G. J. Tredoux
- Department
of Chemistry and Polymer Science, Stellenbosch University, Private Bag
X1, Matieland 7602, South Africa
| | - André de Villiers
- Department
of Chemistry and Polymer Science, Stellenbosch University, Private Bag
X1, Matieland 7602, South Africa
| |
Collapse
|
43
|
Wolfender JL, Marti G, Thomas A, Bertrand S. Current approaches and challenges for the metabolite profiling of complex natural extracts. J Chromatogr A 2015; 1382:136-64. [DOI: 10.1016/j.chroma.2014.10.091] [Citation(s) in RCA: 352] [Impact Index Per Article: 39.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2014] [Revised: 10/23/2014] [Accepted: 10/26/2014] [Indexed: 12/11/2022]
|
44
|
|
45
|
Pyrzynska K, Sentkowska A. Recent Developments in the HPLC Separation of Phenolic Food Compounds. Crit Rev Anal Chem 2014. [DOI: 10.1080/10408347.2013.870027] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
46
|
Willemse CM, Stander MA, Tredoux AG, de Villiers A. Comprehensive two-dimensional liquid chromatographic analysis of anthocyanins. J Chromatogr A 2014; 1359:189-201. [DOI: 10.1016/j.chroma.2014.07.044] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2014] [Revised: 06/25/2014] [Accepted: 07/16/2014] [Indexed: 10/25/2022]
|
47
|
Montero L, Herrero M, Ibáñez E, Cifuentes A. Separation and characterization of phlorotannins from brown algae Cystoseira abies-marina by comprehensive two-dimensional liquid chromatography. Electrophoresis 2014; 35:1644-51. [PMID: 24723338 DOI: 10.1002/elps.201400133] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2014] [Revised: 03/27/2014] [Accepted: 03/27/2014] [Indexed: 12/16/2023]
Abstract
Phlorotannins are an important class of polyphenolic compounds only found in brown algae. The chemical analysis of these bioactive polyphenols is rather difficult due to the great chemical variability and complexity of the natural composition of these components in algae, forming large phloroglucinol polymers. In the present work, a new approach based on the use of comprehensive 2D LC (LC × LC) is shown to analyze this complex family of compounds. The developed LC × LC methodology is based on the coupling of a hydrophilic-interaction LC (HILIC)-based separation in the first dimension and an RP-based separation in the second dimension. The employment of this online coupling together with DAD and MS/MS allowed the separation and identification of more than 50 compounds in a Cystoseira abies-marina brown alga extract. Phlorotannins containing from 5 to 17 phloroglucinol units were identified in this sample by HILIC × RP-DAD-MS/MS. Besides, using the 2,4-dimethoxybenzaldehyde assay, it was possible to determine that the total amount of phlorotannins present in the extract was 40.2 mg phloroglucinol equivalents per gram of extract. To our knowledge, this work is the first demonstration of the usefulness of HILIC × RP-DAD-MS/MS for the determination of phlorotannins.
Collapse
Affiliation(s)
- Lidia Montero
- Laboratory of Foodomics, Institute of Food Science Research (CIAL, CSIC), Campus de Cantoblanco, Madrid, Spain
| | | | | | | |
Collapse
|
48
|
Comprehensive two-dimensional liquid chromatography coupled to the ABTS radical scavenging assay: a powerful method for the analysis of phenolic antioxidants. Anal Bioanal Chem 2014; 406:4233-42. [DOI: 10.1007/s00216-014-7847-z] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2013] [Revised: 03/07/2014] [Accepted: 04/22/2014] [Indexed: 10/25/2022]
|
49
|
Ma J, Hou X, Zhang B, Wang Y, He L. The analysis of carbohydrates in milk powder by a new “heart-cutting” two-dimensional liquid chromatography method. J Pharm Biomed Anal 2014; 91:24-31. [DOI: 10.1016/j.jpba.2013.11.006] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2013] [Revised: 10/31/2013] [Accepted: 11/02/2013] [Indexed: 10/26/2022]
|
50
|
Interpretation of comprehensive two-dimensional gas chromatography data using advanced chemometrics. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2013.08.009] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|