1
|
Warren CG, Dasgupta PK. Liquid phase detection in the miniature scale. Microfluidic and capillary scale measurement and separation systems. A tutorial review. Anal Chim Acta 2024; 1305:342507. [PMID: 38677834 DOI: 10.1016/j.aca.2024.342507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 03/18/2024] [Accepted: 03/19/2024] [Indexed: 04/29/2024]
Abstract
Microfluidic and capillary devices are increasingly being used in analytical applications while their overall size keeps decreasing. Detection sensitivity for these microdevices gains more importance as device sizes and consequently, sample volumes, decrease. This paper reviews optical, electrochemical, electrical, and mass spectrometric detection methods that are applicable to capillary scale and microfluidic devices, with brief introduction to the principles in each case. Much of this is considered in the context of separations. We do consider theoretical aspects of separations by open tubular liquid chromatography, arguably the most potentially fertile area of separations that has been left fallow largely because of lack of scale-appropriate detection methods. We also examine the theoretical basis of zone electrophoretic separations. Optical detection methods discussed include UV/Vis absorbance, fluorescence, chemiluminescence and refractometry. Amperometry is essentially the only electrochemical detection method used in microsystems. Suppressed conductance and especially contactless conductivity (admittance) detection are in wide use for the detection of ionic analytes. Microfluidic devices, integrated to various mass spectrometers, including ESI-MS, APCI-MS, and MALDI-MS are discussed. We consider the advantages and disadvantages of each detection method and compare the best reported limits of detection in as uniform a format as the available information allows. While this review pays more attention to recent developments, our primary focus has been on the novelty and ingenuity of the approach, regardless of when it was first proposed, as long as it can be potentially relevant to miniature platforms.
Collapse
Affiliation(s)
- Cable G Warren
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, 76019-0065, United States
| | - Purnendu K Dasgupta
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, 76019-0065, United States.
| |
Collapse
|
2
|
Li H, Zhao X, Liu L, Yao M, Han Y, Li R, Liu J, Zhang J. Resin screening and process optimization for erythritol mother liquor chromatographic separation. Prep Biochem Biotechnol 2024:1-12. [PMID: 38742596 DOI: 10.1080/10826068.2024.2349936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
In order to improve the utilization value of the erythritol mother liquor, the separation and purification of the erythritol mother liquor was selected in this study. The selected chromatographic separation programme for erythritol crystallizing mother liquor is as follows: Firstly, erythritol is resolved from mannitol and arabitol with DTF-01Ca (Suqing Group) resin and then mannitol is resolved from arabitol with 99Ca/320 (Dowex) resin. At the same time, the chromatographic conditions of the DTF-01Ca (Suqing Group) and 99Ca/320 (Dowex) resins were optimized, resulting in an optimal separation temperature and mobile phase flow rate of 70 °C, 10 ml/min. On this basis, a single-column chromatographic model was used to calculate the TD model parameter (N ) and the mass transfer coefficient (k m ) of the separation of erythritol mother liquor by DTF-01Ca (Suqing Group) and 99Ca/320 (Dowex) resins. The adsorption isotherms, TD model parameter (N ) and the mass transfer coefficient (k m ) provides data references for the design and operation of the simulated moving beds (SMB) separation system for the industrial-scale separation of erythritol crystallizing mother liquor.
Collapse
Affiliation(s)
- Haiyang Li
- Shandong Food Ferment Industry Research & Design Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
- School of Food Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
| | - Xiangying Zhao
- Shandong Food Ferment Industry Research & Design Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
- School of Food Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
| | - Liping Liu
- Shandong Food Ferment Industry Research & Design Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
- School of Food Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
| | - Mingjing Yao
- Shandong Food Ferment Industry Research & Design Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
- School of Food Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
| | - Yanlei Han
- Shandong Food Ferment Industry Research & Design Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
- School of Food Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
| | - Ruiguo Li
- Shandong Food Ferment Industry Research & Design Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
- School of Food Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
| | - Jianjun Liu
- Shandong Food Ferment Industry Research & Design Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
- School of Food Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
| | - Jiaxiang Zhang
- Shandong Food Ferment Industry Research & Design Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
- School of Food Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, China
| |
Collapse
|
3
|
Cardoso AT, Martins RO, Lanças FM, Chaves AR. Molecularly imprinted polymers in online extraction liquid chromatography methods: Current advances and recent applications. Anal Chim Acta 2023; 1284:341952. [PMID: 37996153 DOI: 10.1016/j.aca.2023.341952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 10/20/2023] [Accepted: 10/21/2023] [Indexed: 11/25/2023]
Abstract
BACKGROUND One of the primary objectives in green analytical practices is the seamless integration of extraction and separation steps, resulting in the augmentation of both analytical throughput and method performance. Consequently, the exploration of prospective sorbent materials has drawn significant attention in the scientific community, particularly concerning the potential for online procedures. Employing the optimal sorbent material within an automated analytical approach holds the promise of elevating the precision of the analytical evaluation. Molecularly imprinted polymers (MIPs) excel in specific analyte interaction within complex matrices. However, MIPs' full potential was not widely exploring especially for online analytical methodologies. RESULTS Here is presented a comprehensive overview of the current applications of MIPs as sorbent materials within integrated and automated separation methodologies applied to diverse matrices including biological, food, and environmental samples. Notably, their primary advantage, as evidenced in the literature, lies in their exceptional selectivity for the target analyte discussed according to the adopted synthesis protocol. Furthermore, the literature discussed here illustrates the versatility of MIPs in terms of modification with one or more phases which are so-called hybrid materials, such as molecularly imprinted monoliths (MIM), the molecularly imprinted ionic liquid polymer (IL-MIP), and restricted access to molecularly imprinted polymer (RAMIP). The reported advantages enhance their applicability in integrated and automated separation procedures, especially to the column switching methods, across a broader spectrum of applications. SIGNIFICANCE This revision aims to demonstrate the MIP's potential as a sorbent phase in integrated and automated methods, this comprehensive overview of MIP polymers in integrated and automated separation methodologies can be used as a valuable guide, inspiring new research on developing novel horizons for MIP applications to have their potential emphasized in analytical science and enhanced to the great analytical methods achievement.
Collapse
Affiliation(s)
- Alessandra Timóteo Cardoso
- Universidade Federal de Goiás, Instituto de Química, 74690-900, Goiânia, GO, Brazil; Universidade de São Paulo, Instituto de Química de São Carlos, São Carlos, SP, Brazil
| | | | - Fernando Mauro Lanças
- Universidade de São Paulo, Instituto de Química de São Carlos, São Carlos, SP, Brazil
| | | |
Collapse
|
4
|
Hicks MB, Mattern K, Fine J, Grosser S, Patel D, Weisel L, Aggarwal P. Portable capillary LC for in-line UV monitoring and MS detection: Comparable sensitivity and much lower solvent consumption. J Sep Sci 2023; 46:e2300300. [PMID: 37715328 DOI: 10.1002/jssc.202300300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 08/26/2023] [Accepted: 08/29/2023] [Indexed: 09/17/2023]
Abstract
Pharmaceutical development currently relies on quality separation methods from early discovery through to line-of-site manufacturing. There have been significant advancements made regarding the column particle packing, internal diameter, length connectivity, the understanding of the impact key parameters like void volume, flow rate, and temperature all that affects the resultant separation quality, that is, resolution, peak shape, peak width, run time, and signal-to-noise ratio. There is however a strong need to establish better alternatives to large bulky high-performance liquid chromatography racks either for process analytical reaction monitoring or mass spectrometry analysis in establishing product quality. Compact, portable high-pressure liquid chromatography can be a more efficient alternative to traditional ultra-high pressure liquid chromatography and traditional liquid chromatography. The compact versatile instrument evaluated here allows good separation control with either the on-board column with fixed ultra-violet wavelength cartridge or for use with a high-resolution mass spectrometry. Significant space reduction results in greener lab spaces with improved energy efficiency for smaller labs with lower energy demands. In addition, this compact liquid chromatography was used as a portable reaction monitoring solution to compare forced degradation kinetics and assess portable liquid chromatography-mass spectrometry capability for the analyses required for pharmaceutical drug product testing.
Collapse
Affiliation(s)
- Michael B Hicks
- Analytical Research & Development, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Keith Mattern
- Process Enabling Technologies, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Jonathan Fine
- Analytical Research & Development, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Shane Grosser
- Process Enabling Technologies, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Daya Patel
- Analytical Research & Development, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Lauren Weisel
- Analytical Research & Development, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Pankaj Aggarwal
- Analytical Research & Development, MRL, Merck & Co., Inc., Massachusetts, Boston, USA
| |
Collapse
|
5
|
Medina DAV, Cardoso AT, Borsatto JVB, Lanças FM. Open tubular liquid chromatography: Recent advances and future trends. J Sep Sci 2023; 46:e2300373. [PMID: 37582640 DOI: 10.1002/jssc.202300373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 07/28/2023] [Accepted: 07/31/2023] [Indexed: 08/17/2023]
Abstract
Nano-liquid chromatography (nanoLC) is gaining significant attention as a primary analytical technique across various scientific domains. Unlike conventional high-performance LC, nanoLC utilizes columns with inner diameters (i.ds.) usually ranging from 10 to 150 μm and operates at mobile phase flow rates between 10 and 1000 nl/min, offering improved chromatographic performance and detectability. Currently, most exploration of nanoLC has focused on particle-packed columns. Although open tubular LC (OTLC) can provide superior performance, optimized OTLC columns require very narrow i.ds. (< 10 μm) and demand challenging instrumentation. At the moment, these challenges have limited the success of OTLC. Nevertheless, remarkable progress has been made in developing and utilizing OTLC systems featuring narrow columns (< 2 μm). Additionally, significant efforts have been made to explore larger columns (10-75 μm i.d), demonstrating practical applicability in many situations. Due to their perceived advantages, interest in OTLC has resurged in the last two decades. This review provides an updated outlook on the latest developments in OTLC, focusing on instrumental challenges, achievements, and advancements in column technology. Moreover, it outlines selected applications that illustrate the potential of OTLC for performing targeted and untargeted studies.
Collapse
Affiliation(s)
- Deyber Arley Vargas Medina
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| | - Alessandra Timoteo Cardoso
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| | - João Victor Basolli Borsatto
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| | - Fernando Mauro Lanças
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| |
Collapse
|
6
|
Manetto S, Mazzoccanti G, Mileo V, Moretti E, Villani C, Gasparrini F. A comprehensive study to reveal the potential of a more sustainable ultra-high performance enantioselective reversed-phase chromatography on Pirkle-type stationary phase, with Whelk-O1 as a case study. J Chromatogr A 2023; 1705:464177. [PMID: 37419020 DOI: 10.1016/j.chroma.2023.464177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 06/20/2023] [Accepted: 06/21/2023] [Indexed: 07/09/2023]
Abstract
In this study, we aimed to make enantioselective chromatography more sustainable, more sensitive, and compatible with aqueous formulations analysis and ESI-MS. To achieve this, we examined the effects of transitioning from normal-phase chromatography (which uses hydrocarbon-based solvents) to reversed-phase chromatography (using mobile phases based on water) using broad-spectrum Whelk-O1 columns as a critical study. For the first time, we holistically compared the thermodynamics and kinetics of the two elution modes in order to answer the question of whether same-column chemistry can effectively separate the compounds even in reversed-phase mode and found, unexpectedly, that reversed-phase chromatography using acetonitrile as the organic modifier was competitive from a kinetic standpoint. We also evaluated the effectiveness of three organic modifiers simultaneously on a sample of 11 molecules already resolved in NP conditions with different resolutions and achieved a resolution value of 1.5 for 91% and a resolution value of 2 for 82% of cases. Finally, we separated three racemates (within a k factor of 9) using only 480 µL of solvent per chromatographic run on a millibore column of 1 mm I.D., demonstrating that our approach allows for greener chromatographic separations.
Collapse
Affiliation(s)
- S Manetto
- Dipartimento di Chimica e Tecnologie del Farmaco, Università degli Studi di Roma "La Sapienza", Piazzale Aldo Moro 5, 00185 Roma (Italy).
| | - G Mazzoccanti
- Preclinical Analytics and Early Formulations Department, Chiesi Farmaceutici Spa, Largo Belloli, 43123 Parma (Italy)
| | - V Mileo
- Preclinical Analytics and Early Formulations Department, Chiesi Farmaceutici Spa, Largo Belloli, 43123 Parma (Italy)
| | - E Moretti
- Preclinical Analytics and Early Formulations Department, Chiesi Farmaceutici Spa, Largo Belloli, 43123 Parma (Italy)
| | - C Villani
- Dipartimento di Chimica e Tecnologie del Farmaco, Università degli Studi di Roma "La Sapienza", Piazzale Aldo Moro 5, 00185 Roma (Italy)
| | - F Gasparrini
- Dipartimento di Chimica e Tecnologie del Farmaco, Università degli Studi di Roma "La Sapienza", Piazzale Aldo Moro 5, 00185 Roma (Italy).
| |
Collapse
|
7
|
Shih CH, Ke CH, Hsiao CC. Liquid chromatography on a centrifugal platform for separation and collection of water-soluble dyes. J Chromatogr A 2023; 1705:464211. [PMID: 37480725 DOI: 10.1016/j.chroma.2023.464211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 07/09/2023] [Accepted: 07/11/2023] [Indexed: 07/24/2023]
Abstract
A reversed-phase chromatographic process is developed on a centrifugal platform to separate and collect water-soluble dyes from a mixture. A separation column filled with C18-reversed phase silica gel was used to separate the components from a mixture and the eluate was collected by a series of collecting chambers. The purified components can then be identified and extracted from the collecting chambers. The effects of the silica gel's particle size (7-10, 20-45, and 46-63 µm) and the platform's rotational speed (1000, 1500, 2000 RPM) on the separation and collection efficiency were investigated. Experimental results showed that dye separation could be well performed in the column with smaller-sized silica gels (7-10 µm) under a low rotational speed (1000 RPM). However, for the eluate collection, the high eluent flowrate and long processing time resulted in a convective band-broadening problem in the collecting chambers, which affected the recovery ratio of the dyes. Experimental results showed that the convective band broadening effect can be reduced by reducing the flowrate, shortening the collecting time, and switching the eluent to a different composition. The best recovery ratio of the dyes in the current design can be achieved by using the column with a powder size distribution of 46-63 µm and operating at the rotational speed of 1500 RPM. This platform can process a sample volume of 1 μL and the processing time is about 30 min. Since the only instrument used is a motor, the complete chromatographic process, from separation to fraction collection, can be carried out on a centrifugal platform at a low cost.
Collapse
Affiliation(s)
- Chih-Hsin Shih
- Department of Chemical Engineering, Feng Chia University, 100 Wenhua Road, Taichung 40724, Taiwan.
| | - Chao-Hui Ke
- Department of Chemical Engineering, Feng Chia University, 100 Wenhua Road, Taichung 40724, Taiwan
| | - Chih-Chien Hsiao
- Department of Chemical Engineering, Feng Chia University, 100 Wenhua Road, Taichung 40724, Taiwan
| |
Collapse
|
8
|
Rodríguez-Palma CE, Herráez-Hernández R, Campíns-Falcó P. A modified micro-solid phase extraction device for in-port elution and injection into portable liquid chromatography: A proof-of-concept study. J Chromatogr A 2023; 1705:464216. [PMID: 37480726 DOI: 10.1016/j.chroma.2023.464216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 07/11/2023] [Accepted: 07/13/2023] [Indexed: 07/24/2023]
Abstract
A micro-solid phase extraction (micro-SPE) device packed with a C18 sorbent (10 mg) has been developed for the enrichment and purification of organic water pollutants prior to their analysis using a portable liquid chromatograph with a dual UV detector. To this end, the sorbent was immobilized at the inlet of a 4 mm syringe filter (0.20 µm), which was modified to reduce its internal volume. The filter was coupled to the needle of the chromatograph. After loading the sample and cleaning the sorbent for analyte purification, the device was installed into the injection port of the chromatograph, and the target compounds were desorbed and transferred directly to the chromatographic column with a small volume of organic solvent. Under optimized conditions, sample volumes as large as 50 mL could be processed with the micro-SPE device, while the analytes were desorbed with only 60 µL of methanol. As a result, efficient preconcentration could be reached, as demonstrated for different water contaminants, namely aclonifen, bifenox, tritosulfuron, triflusulfuron-methyl and caffeine. The proposed micro-SPE device was applied to the analysis of different types of water (river, well, sea, ditch and wastewater). The recoveries of the target compounds in samples ranged from 76 % to 109 %, which allowed their detection at low to sub µg/L levels. All operations were carried out manually, and thus, no additional laboratory instruments such as centrifuges, stirrers or evaporators were required. This proof-of-concept study shows that the proposed micro-SPE approach can be considered a reliable and effective option for the on-site analysis of pollutants in environmental water samples by portable liquid chromatography.
Collapse
Affiliation(s)
- C E Rodríguez-Palma
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain
| | - R Herráez-Hernández
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain.
| | - P Campíns-Falcó
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain
| |
Collapse
|
9
|
Ahmed MA, Yu RB, Quirino JP. Recent developments in open tubular liquid chromatography and electrochromatography from 2019–2021. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
|
10
|
Chromatographic supports for enantioselective liquid chromatography: Evolution and innovative trends. J Chromatogr A 2022; 1684:463555. [DOI: 10.1016/j.chroma.2022.463555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Revised: 09/29/2022] [Accepted: 10/06/2022] [Indexed: 11/21/2022]
|
11
|
Vargas Medina DA, Pereira dos Santos NG, Maciel EVS, Lanças FM. Current prospects on nano liquid chromatography coupled to electron ionization mass spectrometry (nanoLC-EI-MS). J LIQ CHROMATOGR R T 2022. [DOI: 10.1080/10826076.2022.2110114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
12
|
Zhao ZX, Chen SZ, Xia ZL, Bin Xu Y, Zhang LL, Tian SM, Fan Q. High level nitrosamines in rat faeces with colorectal cancer determined by a sensitive GC-MS method. J Pharm Biomed Anal 2022; 210:114576. [PMID: 34998074 DOI: 10.1016/j.jpba.2021.114576] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 12/19/2021] [Accepted: 12/30/2021] [Indexed: 12/19/2022]
Abstract
N-nitrosamines (NAs) are common toxic substances that have a strong correlation with many human diseases, such as liver damage and cancer. However, there is a lack of studies on methods involving the detection of NAs in biological samples, possibly owing to the interference of complex biological matrices and the influence of endogenous NAs. In this work, solid-phase extraction with mixed solid phases and adsorption sedimentation were used to successfully establish a gas chromatography-mass spectrometry (GC-MS) method for detecting eight NAs in rat faeces. Chromatographic separation of analytes was performed with Agilent VF-WAXms (30 m × 0.25 mm, 0.25 µm) GC columns. The LLOQs of eight NAs were set to the concentration of 0.5 ng/g and the obtained standard curves were linear, and correlation coefficients (r) were ≥ 0.99 for samples with concentration ranges of 0.5-500 ng/g. The inter and intra-assay precisions were< 15% for all analytes in the quality control samples, and the accuracies ranged from 88.67% to 108.33%. The extraction recoveries were above 78.56% for seven NAs, and a significant matrix effect was not observed. The application of this method revealed that the levels of NAS in the faeces of rats with colorectal cancer were higher than those of normal rats. Additionally, the effect of a high nitrite diet on NAs in faeces was analysed; the results confirmed that a high nitrite diet might contribute to an abnormal increase in NAs. Our work provides an analytical method for further in vivo study of NAs. Furthermore, a pilot study on the relationship between NAs and colorectal cancer was completed.
Collapse
Affiliation(s)
- Zhen Xiong Zhao
- Taizhou Central Hospital (Taizhou University Hospital), Taizhou, Zhejiang 317700, PR China
| | - Sai Zhen Chen
- Taizhou Central Hospital (Taizhou University Hospital), Taizhou, Zhejiang 317700, PR China
| | - Zhe Lin Xia
- Taizhou Central Hospital (Taizhou University Hospital), Taizhou, Zhejiang 317700, PR China
| | - Yu Bin Xu
- Taizhou Central Hospital (Taizhou University Hospital), Taizhou, Zhejiang 317700, PR China
| | - Ling Ling Zhang
- Taizhou Central Hospital (Taizhou University Hospital), Taizhou, Zhejiang 317700, PR China
| | - Shan Ming Tian
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong 250117, PR China
| | - Qing Fan
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong 250117, PR China.
| |
Collapse
|
13
|
Shan L, Jones B. Nano liquid chromatography, an updated review. Biomed Chromatogr 2022; 36:e5317. [PMID: 34981550 DOI: 10.1002/bmc.5317] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Revised: 12/04/2021] [Accepted: 12/09/2021] [Indexed: 11/11/2022]
Abstract
Low flow chromatography has a rich history of innovation but has yet to reach widespread implementation in bioanalytical applications. Improvements in pump technology, microfluidic connections, and nano-electrospray sources for mass spectrometry have laid the groundwork for broader application, and innovation in this space has accelerated in recent years. This article reviews the instrumentation used for nano-flow liquid chromatography , the types of columns employed, and strategies for multi-dimensionality of separations, which is key to the future state of the technique to the high-throughput needs of modern bioanalysis. An update of the current applications where nano-LC is widely used, such as proteomics and metabolomics, is discussed. But the trend towards biopharmaceutical development of increasingly complex, targeted, and potent therapeutics for the safe treatment of disease drives the need for ultimate selectivity and sensitivity of our analytical platforms for targeted quantitation in a regulated space. The selectivity needs are best addressed by mass spectrometric detection, especially at high resolutions, and exquisite sensitivity is provided by nano-electrospray ionization as the technology continues to evolve into an accessible, robust, and easy to use platform.
Collapse
|
14
|
Zhou Y, Guo G, Wang X. Development of
Ultranarrow‐Bore
Open Tubular High Efficiency Liquid Chromatography. CHINESE J CHEM 2022. [DOI: 10.1002/cjoc.202100445] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Yingyan Zhou
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| | - Guangsheng Guo
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| | - Xiayan Wang
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| |
Collapse
|
15
|
Yang M, Li J, Zhao C, Xiao H, Fang X, Zheng J. LC-Q-TOF-MS/MS detection of food flavonoids: principle, methodology, and applications. Crit Rev Food Sci Nutr 2021:1-21. [PMID: 34672231 DOI: 10.1080/10408398.2021.1993128] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
Flavonoids have been attracting increasing research interest because of their multiple health promoting effects. However, many flavonoids with similar structures are present in foods, often at low concentrations, which increases the difficulty of their separation and identification. Liquid chromatography-quadrupole time-of-flight tandem mass spectrometry (LC-Q-TOF-MS/MS) has become one of the most widely used techniques for flavonoid detection. LC-Q-TOF-MS/MS can achieve highly efficient separation by LC; it also provides structural information regarding flavonoids by Q-TOF-MS/MS. This review presents a comprehensive summary of the scientific principles and detailed methodologies (e.g., qualitative determination, quantitative determination, and data processing) of LC-Q-TOF-MS/MS specifically for food flavonoids. It also discusses the recent applications of LC-Q-TOF-MS/MS in determination of flavonoid types and contents in agricultural products, changes in their structures and contents during food processing, and metabolism in vivo after consumption. Moreover, it proposes necessary technological improvements and potential applications. This review would facilitate the scientific understanding of theory and technique of LC-Q-TOF-MS/MS for flavonoid detection, and promote its applications in food and health industry.
Collapse
Affiliation(s)
- Minke Yang
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing, China.,College of Food Science, South China Agricultural University, Guangzhou, China
| | - Juan Li
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing, China
| | - Chengying Zhao
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing, China.,Guangdong Province Key Laboratory of Nutraceuticals and Functional Foods, College of Food Science, South China Agricultural University, Guangzhou, Guangdong, China
| | - Hang Xiao
- Department of Food Science, University of Massachusetts, Amherst, Massachusetts, USA
| | - Xiang Fang
- College of Food Science, South China Agricultural University, Guangzhou, China.,Guangdong Province Key Laboratory of Nutraceuticals and Functional Foods, College of Food Science, South China Agricultural University, Guangzhou, Guangdong, China
| | - Jinkai Zheng
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing, China.,Department of Food Science, University of Massachusetts, Amherst, Massachusetts, USA
| |
Collapse
|
16
|
[Research advances in nano liquid chromatography instrumentation]. Se Pu 2021; 39:1065-1076. [PMID: 34505428 PMCID: PMC9404240 DOI: 10.3724/sp.j.1123.2021.06017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
小型化是液相色谱分离技术发展的重要趋势之一,包括仪器外形尺寸的小型化、分离材料粒径的小型化以及色谱柱内径的小型化。色谱柱内径的减小能够降低样品和流动相的消耗,具有更高的质量灵敏度,特别适合用于复杂样品体系的分离分析。纳升液相色谱一般是指使用内径小于100 μm的毛细管色谱柱,流速范围在每分钟几十至几百纳升的色谱技术。由于流速很低,色谱柱体积很小,柱外效应显著,因此对色谱仪器系统各个模块的性能以及系统柱外效应的优化提出了较高的要求。纳升液相色谱的输液装置需要能够准确稳定地输送纳升级流速,具有梯度输液模式,且拥有一定的耐压能力,以适应不同规格的色谱柱类型;进样装置需要能够进行准确重复的进样过程,进样体积及进样方式适合毛细管色谱柱,同时不产生明显的柱外效应;检测装置需要具有较高的灵敏度,且具有较小的柱外扩散;管路与连接系统需要稳定、可靠、易操作,并能够最大限度地减小柱外体积,适配纳升级流速。鉴于目前大多数纳升液相色谱系统与质谱检测器联用,因而本文主要从输液装置、进样装置、管路与连接3个方面对相关技术领域的研究论文、技术专利以及仪器厂商的宣传文件等进行了检索与归纳,综述了这些模块的技术路线与研究进展,同时简要介绍光学吸收型检测装置的优化思路与研究进展,并对部分商品化的纳升液相色谱系统进行了对比。
Collapse
|
17
|
Coppieters G, Deventer K, Van Eenoo P, Judák P. Combining direct urinary injection with automated filtration and nanoflow LC-MS for the confirmatory analysis of doping-relevant small peptide hormones. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1179:122842. [PMID: 34216910 DOI: 10.1016/j.jchromb.2021.122842] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 06/16/2021] [Accepted: 06/18/2021] [Indexed: 01/17/2023]
Abstract
Nano-liquid chromatography (nanoLC) has proven itself as a powerful tool and its scope entails various applications in (bio)analytical fields. Operation at low (nL/min) flow rates in combination with reduced inner dimensions (ID < 100 µm), leads to significantly enhanced sensitivity when coupled with electrospray ionization-mass spectrometry (ESI-MS). Challenges that remain for the routine implementation of such miniaturized setups are related to clogging of the system and robustness in general, and thus the application of tedious sample preparation steps. To improve ruggedness, a filter placed upstream in the LC prevents particles from entering and clogging the system. This so-called online automatic filtration and filter back-flush (AFFL) system was combined with nanoLC and the direct injection principle for the sensitive confirmatory analysis of fifty different doping-relevant peptides in urine. The presented assay was fully validated for routine purposes according to selectivity and matrix interference, limit of identification (LOI), carryover, matrix effect, sample extract stability, analysis of educational external quality assessment (EQAS) samples, robustness of the online AFFL-setup and retention time stability. It was also fully compliant with the most recent minimum required performance levels (MRPL) and chromatographic/mass spectrometric identification criteria (IDCR), as imposed by the World Anti-Doping Agency (WADA). In the absence of labor-intensive sample preparation, the application of AFFL allowed for the injection of diluted urine samples without any noticeable pressure buildup in the nanoLC system. Contrary to earlier observations by our group and others, the addition of dimethylsulfoxide (DMSO) to the mobile phase did not enhance sensitivity in the presented nanoflow setup, yet was beneficial to reduce carry over. Although the robustness of the presented setup was evaluated only for the analysis of diluted urine samples, it is entirely conceivable that routine applications employing other matrices and currently running on analytical scale LC instruments could be transferred to micro/nanoLC scale systems to reach lower detection limits.
Collapse
Affiliation(s)
- Gilles Coppieters
- Doping Control Laboratory (DoCoLab), Ghent University, Department Diagnostic Sciences, Ottergemsesteenweg 460, B-9000 Ghent, Belgium.
| | - Koen Deventer
- Doping Control Laboratory (DoCoLab), Ghent University, Department Diagnostic Sciences, Ottergemsesteenweg 460, B-9000 Ghent, Belgium
| | - Peter Van Eenoo
- Doping Control Laboratory (DoCoLab), Ghent University, Department Diagnostic Sciences, Ottergemsesteenweg 460, B-9000 Ghent, Belgium
| | - Péter Judák
- Doping Control Laboratory (DoCoLab), Ghent University, Department Diagnostic Sciences, Ottergemsesteenweg 460, B-9000 Ghent, Belgium
| |
Collapse
|
18
|
Ramadan Q, Fardous RS, Hazaymeh R, Alshmmari S, Zourob M. Pharmacokinetics-On-a-Chip: In Vitro Microphysiological Models for Emulating of Drugs ADME. Adv Biol (Weinh) 2021; 5:e2100775. [PMID: 34323392 DOI: 10.1002/adbi.202100775] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Revised: 06/08/2021] [Indexed: 12/15/2022]
Abstract
Despite many ongoing efforts across the full spectrum of pharmaceutical and biotech industries, drug development is still a costly undertaking that involves a high risk of failure during clinical trials. Animal models played vital roles in understanding the mechanism of human diseases. However, the use of these models has been a subject of heated debate, particularly due to ethical matters and the inevitable pathophysiological differences between animals and humans. Current in vitro models lack the sufficient functionality and predictivity of human pharmacokinetics and toxicity, therefore, are not capable to fully replace animal models. The recent development of micro-physiological systems has shown great potential as indispensable tools for recapitulating key physiological parameters of humans and providing in vitro methods for predicting the pharmacokinetics and pharmacodynamics in humans. Integration of Absorption, Distribution, Metabolism, and Excretion (ADME) processes within one close in vitro system is a paramount development that would meet important unmet pharmaceutical industry needs. In this review paper, synthesis of the ADME-centered organ-on-a-chip technology is systemically presented from what is achieved to what needs to be done, emphasizing the requirements of in vitro models that meet industrial needs in terms of the structure and functions.
Collapse
Affiliation(s)
- Qasem Ramadan
- Alfaisal University, Riyadh, 11533, Kingdom of Saudi Arabia
| | - Roa Saleem Fardous
- Alfaisal University, Riyadh, 11533, Kingdom of Saudi Arabia.,Strathclyde Institute of Pharmacy and Biomedical Sciences, Strathclyde University, Glasgow, G4 0RE, United Kingdom
| | - Rana Hazaymeh
- Almaarefa University, Riyadh, 13713, Kingdom of Saudi Arabia
| | - Sultan Alshmmari
- Saudi Food and Drug Authority, Riyadh, 13513-7148, Kingdom of Saudi Arabia
| | | |
Collapse
|
19
|
Ponce-Rodríguez HD, Verdú-Andrés J, Campíns-Falcó P, Herráez-Hernández R. Capillary Liquid Chromatography for the Determination of Terpenes in Botanical Dietary Supplements. Pharmaceuticals (Basel) 2021; 14:ph14060580. [PMID: 34204518 PMCID: PMC8234297 DOI: 10.3390/ph14060580] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 06/15/2021] [Accepted: 06/16/2021] [Indexed: 12/17/2022] Open
Abstract
Dietary supplements of botanical origin are increasingly consumed due to their content of plant constituents with potential benefits on health and wellness. Among those constituents, terpenes are gaining attention because of their diverse biological activities (anti-inflammatory, antibacterial, geroprotective, and others). While most of the existing analytical methods have focused on establishing the terpenic fingerprint of some plants, typically by gas chromatography, methods capable of quantifying representative terpenes in herbal preparations and dietary supplements with combined high sensitivity and precision, simplicity, and high throughput are still necessary. In this study, we have explored the utility of capillary liquid chromatography (CapLC) with diode array detection (DAD) for the determination of different terpenes, namely limonene, linalool, farnesene, α-pinene, and myrcene. An innovative method is proposed that can be applied to quantify the targets at concentration levels as low as 0.006 mg per gram of sample with satisfactory precision, and a total analysis time <30 min per sample. The reliability of the proposed method has been tested by analyzing different dietary supplements of botanical origin, namely three green coffee extract-based products, two fat burnings containing Citrus aurantium (bitter orange), and an herbal preparation containing lime and leaves of orange trees.
Collapse
Affiliation(s)
- Henry Daniel Ponce-Rodríguez
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, València, Spain; (H.D.P.-R.); (J.V.-A.); (P.C.-F.)
- Departamento de Control Químico, Facultad de Química y Farmacia, Universidad Nacional Autónoma de Honduras, Ciudad Universitaria, Tegucigalpa 11101, Honduras
| | - Jorge Verdú-Andrés
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, València, Spain; (H.D.P.-R.); (J.V.-A.); (P.C.-F.)
| | - Pilar Campíns-Falcó
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, València, Spain; (H.D.P.-R.); (J.V.-A.); (P.C.-F.)
| | - Rosa Herráez-Hernández
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, València, Spain; (H.D.P.-R.); (J.V.-A.); (P.C.-F.)
- Correspondence: ; Tel.: +34-96-3544978
| |
Collapse
|
20
|
Thompson AJ, Bourke CD, Robertson RC, Shivakumar N, Edwards CA, Preston T, Holmes E, Kelly P, Frost G, Morrison DJ. Understanding the role of the gut in undernutrition: what can technology tell us? Gut 2021; 70:gutjnl-2020-323609. [PMID: 34103403 PMCID: PMC8292602 DOI: 10.1136/gutjnl-2020-323609] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Accepted: 05/04/2021] [Indexed: 12/22/2022]
Abstract
Gut function remains largely underinvestigated in undernutrition, despite its critical role in essential nutrient digestion, absorption and assimilation. In areas of high enteropathogen burden, alterations in gut barrier function and subsequent inflammatory effects are observable but remain poorly characterised. Environmental enteropathy (EE)-a condition that affects both gut morphology and function and is characterised by blunted villi, inflammation and increased permeability-is thought to play a role in impaired linear growth (stunting) and severe acute malnutrition. However, the lack of tools to quantitatively characterise gut functional capacity has hampered both our understanding of gut pathogenesis in undernutrition and evaluation of gut-targeted therapies to accelerate nutritional recovery. Here we survey the technology landscape for potential solutions to improve assessment of gut function, focussing on devices that could be deployed at point-of-care in low-income and middle-income countries (LMICs). We assess the potential for technological innovation to assess gut morphology, function, barrier integrity and immune response in undernutrition, and highlight the approaches that are currently most suitable for deployment and development. This article focuses on EE and undernutrition in LMICs, but many of these technologies may also become useful in monitoring of other gut pathologies.
Collapse
Affiliation(s)
- Alex J Thompson
- Hamlyn Centre for Robotic Surgery, Department of Surgery and Cancer, Imperial College London, London, UK
| | - Claire D Bourke
- Blizard Institute, Barts & The London School of Medicine, Queen Mary University of London, London, UK
| | - Ruairi C Robertson
- Blizard Institute, Barts & The London School of Medicine, Queen Mary University of London, London, UK
| | - Nirupama Shivakumar
- Division of Nutrition, St John's National Academy of Health Sciences, Bangalore, Karnataka, India
| | | | - Tom Preston
- Stable Isotope Biochemistry Laboratory, Scottish Universities Environmental Research Centre, East Kilbride, UK
| | - Elaine Holmes
- Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
| | - Paul Kelly
- Blizard Institute, Barts & The London School of Medicine, Queen Mary University of London, London, UK
- Tropical Gastroenterology and Nutrition Group, University of Zambia School of Medicine, Lusaka, Zambia
| | - Gary Frost
- Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
| | - Douglas J Morrison
- Stable Isotope Biochemistry Laboratory, Scottish Universities Environmental Research Centre, East Kilbride, UK
| |
Collapse
|
21
|
Diffraction-based label-free photothermal detector for separation analyses in a nanocapillary. J Chromatogr A 2021; 1648:462214. [PMID: 34004365 DOI: 10.1016/j.chroma.2021.462214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 04/19/2021] [Accepted: 04/25/2021] [Indexed: 11/23/2022]
Abstract
Miniaturization of column diameter in liquid chromatography is one of the major trends in separation sciences toward single-cell proteomics and metabolomics. Micro/nanoscale open tubular (OT) capillaries are promising tools for efficient separation analyses of the ultra-small volume of samples. However, highly sensitive and label-free on-column detection is still challenging for such ultra-small capillaries. In this study, we developed a photothermal detector using optical diffraction phenomena by a single nanocapillary. Our detection method realized concentration determination of unlabeled sample solutions in a nanocapillary with 460 nm inner diameter. The calculated limit of detection was 0.12 µM, which corresponds to 16 molecules in a detection volume of 0.23 fL. Furthermore, normal-phase chromatography was performed on a 12 cm long nanocapillary, and femtoliter sample injection, efficient separation, and label-free detection of dye molecules were demonstrated. Our photothermal detector will be widely used as a universal tool for chemical/biological analyses using capillaries with micro/nanoscale diameters.
Collapse
|
22
|
Advancements in the preparation and application of monolithic silica columns for efficient separation in liquid chromatography. Talanta 2021; 224:121777. [PMID: 33379011 DOI: 10.1016/j.talanta.2020.121777] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 10/11/2020] [Accepted: 10/12/2020] [Indexed: 01/23/2023]
Abstract
Fast and efficient separation remains a big challenge in high performance liquid chromatography (HPLC). The need for higher efficiency and resolution in separation is constantly in demand. To achieve that, columns developed are rapidly moving towards having smaller particle sizes and internal diameters (i.d.). However, these parameters will lead to high back-pressure in the system and will burden the pumps of the HPLC instrument. To address this limitation, monolithic columns, especially silica-based monolithic columns have been introduced. These columns are being widely investigated for fast and efficient separation of a wide range of molecules. The present article describes the current methods developed to enhance the column efficiency of particle packed columns and how silica monolithic columns can act as an alternative in overcoming the low permeability of particle packed columns. The fundamental processes behind the fabrication of the monolith including the starting materials and the silica sol-gel process will be discussed. Different monolith derivatization and end-capping processes will be further elaborated and followed by highlights of the performance such monolithic columns in key applications in different fields with various types of matrices.
Collapse
|
23
|
Huang W. Open tubular ion chromatography: A state-of-the-Art review. Anal Chim Acta 2021; 1143:210-224. [PMID: 33384120 DOI: 10.1016/j.aca.2020.08.012] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 08/04/2020] [Accepted: 08/06/2020] [Indexed: 11/19/2022]
Abstract
This review summarizes the progress in open tubular ion chromatography (OTIC) over the period from 1981 to 2020. Although OTIC columns provide superior column efficiency, require very little sample volumes, and consume a minimum level of eluents compared to regular packed columns, not many reports can be found from the literature mainly due to the difficulties in the preparation of OTIC columns and the harsh system requirements, such as pL-nL injections and extremely small detection volumes. However, technical advances, e.g., capacitively coupled contactless conductivity detectors (C4Ds), hydroxide eluent compatible polymer-based OTIC columns, electrodialytic capillary suppressors, and nanovolume gas-free hydroxide eluent generators (EGs), have removed the obstacles to OTIC. As such, in this review, the author focused on the development of the key components in an OTIC system from the perspective of instrument development. A brief revisit of open tubular (OT) column theory is first presented, followed by a discussion of the system configuration and component development. Attention is given to the advances in the development of the suppressed open tubular ion chromatography (SOTIC) system.
Collapse
Affiliation(s)
- Weixiong Huang
- School of Environmental Studies, China University of Geosciences, Wuhan, 430078, Hubei, China.
| |
Collapse
|
24
|
Miniaturization of liquid chromatography coupled to mass spectrometry. 3. Achievements on chip-based LC–MS devices. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.116003] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
25
|
Dogan A, Eylem CC, Akduman NEB. Application of green methodology to pharmaceutical analysis using eco-friendly ethanol-water mobile phases. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104895] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
26
|
Mielczarek P, Silberring J, Smoluch M. MINIATURIZATION IN MASS SPECTROMETRY. MASS SPECTROMETRY REVIEWS 2020; 39:453-470. [PMID: 31793697 DOI: 10.1002/mas.21614] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Accepted: 11/14/2019] [Indexed: 06/10/2023]
Abstract
Expectations for continuous miniaturization in mass spectrometry are not declining for years. Portable instruments are highly welcome by the industry, science, space agencies, forensic laboratories, and many other units. All are striving for the small, cheap, and as good as possible instruments. This review describes the recent developments of miniature mass spectrometers and also provides selected applications where these devices are used. Upcoming perspectives of further development are also discussed. @ 2019 John Wiley & Sons Ltd. Mass Spec Rev.
Collapse
Affiliation(s)
- Przemyslaw Mielczarek
- Department of Biochemistry and Neurobiology, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Mickiewicza 30, 30-059, Krakow, Poland
- Laboratory of Proteomics and Mass Spectrometry, Maj Institute of Pharmacology, Polish Academy of Sciences, Smetna 12, 31-343, Krakow, Poland
| | - Jerzy Silberring
- Department of Biochemistry and Neurobiology, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Mickiewicza 30, 30-059, Krakow, Poland
- Centre of Polymer and Carbon Materials, Polish Academy of Sciences, Curie-Sklodowskiej St. 34, 41-819, Zabrze, Poland
| | - Marek Smoluch
- Department of Biochemistry and Neurobiology, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Mickiewicza 30, 30-059, Krakow, Poland
| |
Collapse
|
27
|
Aydoğan C, Rigano F, Krčmová LK, Chung DS, Macka M, Mondello L. Miniaturized LC in Molecular Omics. Anal Chem 2020; 92:11485-11497. [DOI: 10.1021/acs.analchem.0c01436] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Cemil Aydoğan
- Biochemistry Division, Department of Chemistry, Bingöl University, Bingöl 12000,Turkey
- Department of Food Engineering, Bingöl University, Bingöl 12000,Turkey
| | - Francesca Rigano
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina I-98168, Italy
| | - Lenka Kujovská Krčmová
- Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Akademika Heyrovského 1203, Hradec Králové 500 05, Czech Republic
- Department of Clinical Biochemistry and Diagnostics, University Hospital, Sokolská 581, Hradec Králové 500 05, Czech Republic
| | - Doo Soo Chung
- Department of Chemistry, Seoul National University, Seoul 08826, Korea
| | - Mirek Macka
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno, Czech Republic
- Central European Institute of Technology, Brno University of Technology, Technicka 3058/10, CZ-616 00Brno, Czech Republic
- School of Natural Sciences and Australian Centre for Research on Separation Science (ACROSS), University of Tasmania, Private Bag 75, Hobart 7001, Australia
| | - Luigi Mondello
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina I-98168, Italy
- Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina I-98168, Italy
- Department of Sciences and Technologies for Human and Environment, University Campus Bio-Medico of Rome, Rome I-00128, Italy
- BeSep s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina I-98168, Italy
| |
Collapse
|
28
|
Desmet G, de Beeck JO, Van Raemdonck G, Van Mol K, Claerebout B, Van Landuyt N, Jacobs P. Separation efficiency kinetics of capillary flow micro-pillar array columns for liquid chromatography. J Chromatogr A 2020; 1626:461279. [DOI: 10.1016/j.chroma.2020.461279] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 05/05/2020] [Accepted: 05/25/2020] [Indexed: 02/07/2023]
|
29
|
Vargas Medina DA, Maciel EVS, de Toffoli AL, Lanças FM. Miniaturization of liquid chromatography coupled to mass spectrometry. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115910] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
30
|
Innovations in Extractive Phases for In-Tube Solid-Phase Microextraction Coupled to Miniaturized Liquid Chromatography: A Critical Review. Molecules 2020; 25:molecules25102460. [PMID: 32466305 PMCID: PMC7287690 DOI: 10.3390/molecules25102460] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 05/19/2020] [Accepted: 05/22/2020] [Indexed: 02/06/2023] Open
Abstract
Over the past years, a great effort has been devoted to the development of new sorbents that can be used to pack or to coat extractive capillaries for in-tube solid-phase microextraction (IT-SPME). Many of those efforts have been focused on the preparation of capillaries for miniaturized liquid chromatography (LC) due to the reduced availability of capillary columns with appropriate dimensions for this kind of system. Moreover, many of the extractive capillaries that have been used for IT-SPME so far are segments of open columns from the gas chromatography (GC) field, but the phase nature and dimensions are very limited. In particular, polar compounds barely interact with stationary GC phases. Capillary GC columns may also be unsuitable when highly selective extractions are needed. In this work, we provide an overview of the extractive capillaries that have been specifically developed for capillary LC (capLC) and nano LC (nanoLC) to enhance the overall performance of the IT-SPME, the chromatographic separation, and the detection. Different monolithic polymers, such as silica C18 and C8 polymers, molecularly imprinted polymers (MIPs), polymers functionalized with antibodies, and polymers reinforced with different types of carbon nanotubes, metal, and metal oxide nanoparticles (including magnetic nanoparticles), and restricted access materials (RAMs) will be presented and critically discussed.
Collapse
|
31
|
Mejía-Carmona K, Maciel EVS, Lanças FM. Miniaturized liquid chromatography applied to the analysis of residues and contaminants in food: A review. Electrophoresis 2020; 41:1680-1693. [PMID: 32359175 DOI: 10.1002/elps.202000019] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2020] [Revised: 04/15/2020] [Accepted: 04/17/2020] [Indexed: 12/21/2022]
Abstract
The humankind is pretty dependent on food to control several biological processes into the organism. As the world population increases, the demand for foodstuffs follows the same trend claiming for a high food production situation. For this reason, a substantial amount of chemicals is used in agriculture and livestock husbandries every year, enhancing the likelihood of contaminated foodstuffs being commercialized. This outlook becomes a public health concern; thus, the governmental regulatory agencies impose laws to control the residues and contaminants in food matrices. Currently, one of the most important analytical techniques to perform it is LC. Despite its already recognized effectiveness, it is often time consuming and requires significant volumes of reagents, which are transformed into toxic waste. In this context, miniaturized LC modes emerge as a greener and more effective analytical technique. They have remarkable advantages, including higher sensitivity, lower sample amount, solvent and stationary phase requirements, and more natural coupling to MS. In this review, most of the critical characteristics of them are discussed, focusing on the benchtop instruments and their related analytical columns. Additionally, a discussion regarding the last 10 years of publications reporting miniaturized LC application for the analysis of natural and industrial food samples is categorized. The main chemical classes as applied in the crops are highlighted, including pesticides, veterinary drugs, and mycotoxins.
Collapse
Affiliation(s)
- Karen Mejía-Carmona
- São Carlos Institute of Chemistry, University of São Paulo, São Paulo, Brazil
| | | | | |
Collapse
|
32
|
|
33
|
Serra-Mora P, Herráez-Hernández R, Campíns-Falcó P. Bimodal copper oxide nanoparticles doped phase for the extraction of highly polar compounds by in-tube solid-phase microextraction coupled on-line to nano-liquid chromatography. J Chromatogr A 2020; 1617:460819. [DOI: 10.1016/j.chroma.2019.460819] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Revised: 11/25/2019] [Accepted: 12/18/2019] [Indexed: 10/25/2022]
|
34
|
Miniaturized liquid chromatography focusing on analytical columns and mass spectrometry: A review. Anal Chim Acta 2020; 1103:11-31. [DOI: 10.1016/j.aca.2019.12.064] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 12/19/2019] [Accepted: 12/20/2019] [Indexed: 12/17/2022]
|
35
|
Foster SW, Xie X, Pham M, Peaden PA, Patil LM, Tolley LT, Farnsworth PB, Tolley HD, Lee ML, Grinias JP. Portable capillary liquid chromatography for pharmaceutical and illicit drug analysis. J Sep Sci 2020; 43:1623-1627. [PMID: 31960568 DOI: 10.1002/jssc.201901276] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 01/15/2020] [Accepted: 01/16/2020] [Indexed: 12/12/2022]
Abstract
A newly developed portable capillary liquid chromatograph was investigated for the separation of various pharmaceutical and illicit drug compounds. The system consists of two high-pressure syringe pumps capable of delivering capillary-scale flow rates at pressures up to 10 000 psi. Capillary liquid chromatography columns packed with sub-2 μm particles are housed in cartridges that can be inserted into the system and easily connected through high-pressure fluidic contact points by simply applying a specific, predetermined torque rather than using standard fittings and less precise sealing protocols. Several over-the-counter analgesic drug separations are demonstrated, along with a simple online measurement of tablet dissolution. Twenty illicit drug compounds were also separated across six targeted drug panels. The results described in this study demonstrate the capability of this compact liquid chromatography instrument to address several important drug-related applications while simplifying system operation, and greatly reducing solvent usage and waste generation essential for onsite analysis.
Collapse
Affiliation(s)
- Samuel W Foster
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ
| | | | - Michelle Pham
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ
| | | | - Leena M Patil
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT
| | | | - Paul B Farnsworth
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT
| | - H Dennis Tolley
- Department of Statistics, Brigham Young University, Provo, UT
| | - Milton L Lee
- Axcend Corporation, Provo, UT.,Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT
| | - James P Grinias
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ
| |
Collapse
|
36
|
Mejía-Carmona K, Soares da Silva Burato J, Borsatto JVB, de Toffoli AL, Lanças FM. Miniaturization of liquid chromatography coupled to mass spectrometry. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2019.115735] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
37
|
Lam SC, Coates LJ, Hemida M, Gupta V, Haddad PR, Macka M, Paull B. Miniature and fully portable gradient capillary liquid chromatograph. Anal Chim Acta 2019; 1101:199-210. [PMID: 32029112 DOI: 10.1016/j.aca.2019.12.014] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Revised: 12/05/2019] [Accepted: 12/06/2019] [Indexed: 12/24/2022]
Abstract
A robust, portable and miniature battery powered gradient capillary liquid chromatograph (total weight ∼2.7 kg, without battery ∼2.0 kg), with integrated microfluidic injection, column heating and high sensitivity low-UV absorbance detection is presented. The portable capillary chromatograph, was applied with a packed reversed-phase capillary column (100 mm × 300 μm I.D., 5 μm ODS), housed within an integrated capillary column heater controlled by a proportional-integral-derivative (PID) chip module. The system delivered retention time and peak area relative standard deviation in isocratic mode of <0.7% (n = 10) and <3.3% (n = 10), respectively, and <0.1% (n = 10) and <2.3% (n = 10) respectively, for gradient elution mode. Detection was based upon a 255 nm light-emitting diode (LED) using one of two commercial capillary flow-cell options, namely a high sensitivity 12 nL Agilent capillary z-cell (HSDC) and a 45 nL Thermo Fisher Scientific UZ-View™ flow cell (UZFC). The HSDC, housed within a 3D printed detector arrangement, gave an effective pathlength of 1.01 mm (84% of nominal pathlength) and stray light of only 0.2%. Limits of detection for four test small molecule pharmaceuticals ranged from 65 to 101 μg L-1 based upon a 316 nL injection volume, with separation efficiencies of between 18,000 and 29,700 N m-1, with sub-4 min run times. The portable capillary LC system was successfully coupled to a small footprint portable mass spectrometer (Microsaic 4500 MiD) to demonstrate compatibility and 'point-of-need' miniaturised LC-MS capability.
Collapse
Affiliation(s)
- Shing Chung Lam
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia
| | - Lewellwyn Joseph Coates
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia; Trajan Scientific and Medical, Ringwood, Victoria, 3134, Australia
| | - Mohamed Hemida
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia
| | - Vipul Gupta
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia
| | - Paul R Haddad
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia
| | - Mirek Macka
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia; Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, 612 00, Brno, Czech Republic
| | - Brett Paull
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia.
| |
Collapse
|
38
|
|
39
|
Ponce-Rodríguez HD, Herráez-Hernández R, Verdú-Andrés J, Campíns-Falcó P. Quantitative Analysis of Terpenic Compounds in Microsamples of Resins by Capillary Liquid Chromatography. Molecules 2019; 24:molecules24224068. [PMID: 31717646 PMCID: PMC6891497 DOI: 10.3390/molecules24224068] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 10/30/2019] [Accepted: 11/08/2019] [Indexed: 12/01/2022] Open
Abstract
A method has been developed for the separation and quantification of terpenic compounds typically used as markers in the chemical characterization of resins based on capillary liquid chromatography coupled to UV detection. The sample treatment, separation and detection conditions have been optimized in order to analyze compounds of different polarities and volatilities in a single chromatographic run. The monoterpene limonene and the triterpenes lupeol, lupenone, β-amyrin, and α-amyrin have been selected as model compounds. The proposed method provides linear responses and precision (expressed as relative standard deviations) of 0.6% to 17%, within the 0.5–10.0 µg mL−1 concentration interval; the limits of detection (LODs) and quantification (LOQs) were 0.1–0.25 µg mL−1 and 0.4–0.8 µg mL−1, respectively. The method has been applied to the quantification of the target compounds in microsamples. The reliability of the proposed conditions has been tested by analyzing three resins, white copal, copal in tears, and ocote tree resin. Percentages of the triterpenes in the range 0.010% to 0.16% were measured using sample amounts of 10–15 mg, whereas the most abundant compound limonene (≥0.93%) could be determined using 1 mg portions of the resins. The proposed method can be considered complementary to existing protocols aimed at establishing the chemical fingerprint of these kinds of samples.
Collapse
Affiliation(s)
- H. D. Ponce-Rodríguez
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr Moliner 50, 46100 Burjassot, Valencia, Spain; (H.D.P.-R.); (P.C.-F.)
- Department of Chemical Control, Faculty of Chemistry and Pharmacy, National Autonomous University of Honduras, Ciudad Universitaria, 11101 Tegucigalpa, Honduras
| | - R. Herráez-Hernández
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr Moliner 50, 46100 Burjassot, Valencia, Spain; (H.D.P.-R.); (P.C.-F.)
- Correspondence: (R.H.-H); (J.V.-A)
| | - J. Verdú-Andrés
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr Moliner 50, 46100 Burjassot, Valencia, Spain; (H.D.P.-R.); (P.C.-F.)
- Correspondence: (R.H.-H); (J.V.-A)
| | - P. Campíns-Falcó
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr Moliner 50, 46100 Burjassot, Valencia, Spain; (H.D.P.-R.); (P.C.-F.)
| |
Collapse
|
40
|
Maciel EVS, de Toffoli AL, Neto ES, Nazario CED, Lanças FM. New materials in sample preparation: Recent advances and future trends. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.115633] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
41
|
Sun G, Kim YS, Kim JS, Ali F, An HJ, Cheong WJ. 100 Micrometer bore open tubular capillary column modified with linear co-polymer chains for application in low pressure liquid chromatography. J LIQ CHROMATOGR R T 2019. [DOI: 10.1080/10826076.2019.1667821] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Genlin Sun
- Department of Chemistry, Inha University, Michuhol-gu, Incheon, South Korea
| | - Yune Sung Kim
- Department of Chemistry, Inha University, Michuhol-gu, Incheon, South Korea
| | - Jeong Soo Kim
- Department of Chemistry, Inha University, Michuhol-gu, Incheon, South Korea
| | - Faiz Ali
- Department of Chemistry, University of Malakand, KPK, Pakistan
| | - Hyun Joo An
- Graduate School of Analytical Science and Technology, Chungnam National University, Daejeon, South Korea
| | - Won Jo Cheong
- Department of Chemistry, Inha University, Michuhol-gu, Incheon, South Korea
| |
Collapse
|
42
|
Piendl SK, Raddatz CR, Hartner NT, Thoben C, Warias R, Zimmermann S, Belder D. 2D in Seconds: Coupling of Chip-HPLC with Ion Mobility Spectrometry. Anal Chem 2019; 91:7613-7620. [DOI: 10.1021/acs.analchem.9b00302] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Sebastian K. Piendl
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Christian-Robert Raddatz
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Nora T. Hartner
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Christian Thoben
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Rico Warias
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Stefan Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Detlev Belder
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| |
Collapse
|
43
|
Aydoğan C, Gökaltun A, Denizli A, El‐Rassi Z. Organic polymer‐based monolithic capillary columns and their applications in food analysisψ. J Sep Sci 2019; 42:962-979. [DOI: 10.1002/jssc.201801051] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2018] [Revised: 12/13/2018] [Accepted: 12/18/2018] [Indexed: 01/09/2023]
Affiliation(s)
- Cemil Aydoğan
- Department of Food EngineeringBingöl University Bingöl Turkey
| | - Aslıhan Gökaltun
- Department of Chemical EngineeringHacettepe University Ankara Turkey
| | - Adil Denizli
- Department of ChemistryHacettepe University Ankara Turkey
| | - Ziad El‐Rassi
- Department of ChemistryOklahoma State University Stillwater OK USA
| |
Collapse
|
44
|
Shimizu H, Toyoda K, Mawatari K, Terabe S, Kitamori T. Femtoliter Gradient Elution System for Liquid Chromatography Utilizing Extended Nanofluidics. Anal Chem 2019; 91:3009-3014. [PMID: 30661360 DOI: 10.1021/acs.analchem.8b05302] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
A gradient system was developed for the separation of proteins on a femtoliter scale utilizing nanofluidic channels. In the history of chromatography, miniaturization of the separation column has been important for efficient separation and downsizing of instruments. Previously, our group developed a small and highly efficient chromatography system utilizing nanofluidic channels, although a flexible design of the gradient was difficult and separation of proteins was not achieved. Here, we propose a flexible gradient system using standard HPLC pumps and an auxiliary mixer with a simple sample injection system. In contrast to our previous sample injection system using pressure balance, the system enables a femtoliter-scale sample injection which is compatible with gradient elution using HPLC pumps. The system was carefully designed, verified for sample injection and gradient elution, and finally applied to the separation of proteins from model and real samples. This femtoliter-scale, efficient separation system will contribute to omics studies at the single-cell level.
Collapse
Affiliation(s)
- Hisashi Shimizu
- International Research Center for Neurointelligence , The University of Tokyo , 7-3-1, Hongo , Bunkyo, Tokyo 113-0033 , Japan
| | - Kouto Toyoda
- Department of Applied Chemistry, School of Engineering , The University of Tokyo , 7-3-1, Hongo , Bunkyo, Tokyo 113-8656 , Japan
| | - Kazuma Mawatari
- Department of Applied Chemistry, School of Engineering , The University of Tokyo , 7-3-1, Hongo , Bunkyo, Tokyo 113-8656 , Japan
| | - Shigeru Terabe
- Graduate School of Material Science , University of Hyogo , 3-2-1, Kouto , Kamigori , Hyogo 678-1297 , Japan
| | - Takehiko Kitamori
- Department of Applied Chemistry, School of Engineering , The University of Tokyo , 7-3-1, Hongo , Bunkyo, Tokyo 113-8656 , Japan
| |
Collapse
|
45
|
GAMA MARIANAR, MELCHERT WANESSAR, PAIXÃO THIAGOR, ROCHA FÁBIOR. An overview of the Brazilian contributions to Green Analytical Chemistry. ACTA ACUST UNITED AC 2019; 91:e20180294. [DOI: 10.1590/0001-3765201920180294] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Accepted: 04/17/2018] [Indexed: 12/11/2022]
|
46
|
Lam SC, Sanz Rodriguez E, Haddad PR, Paull B. Recent advances in open tubular capillary liquid chromatography. Analyst 2019; 144:3464-3482. [DOI: 10.1039/c9an00329k] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
This review covers advances and applications of open tubular capillary liquid chromatography (OT-LC) over the period 2007–2018.
Collapse
Affiliation(s)
- Shing Chung Lam
- ASTech
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech)
- and Australian Centre for Research on Separation Science (ACROSS)
- School of Natural Sciences
- University of Tasmania
| | - Estrella Sanz Rodriguez
- ASTech
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech)
- and Australian Centre for Research on Separation Science (ACROSS)
- School of Natural Sciences
- University of Tasmania
| | - Paul R. Haddad
- ASTech
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech)
- and Australian Centre for Research on Separation Science (ACROSS)
- School of Natural Sciences
- University of Tasmania
| | - Brett Paull
- ASTech
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech)
- and Australian Centre for Research on Separation Science (ACROSS)
- School of Natural Sciences
- University of Tasmania
| |
Collapse
|
47
|
Abstract
A strategy for the preparation of silica-based monolithic capillary columns (150 × 0.1 mm) with high selectivity to amino acids is presented. The zwitterionic columns were prepared by coating the silica monolith with [2-(methacryloyloxy)ethyl]-dimethyl-(3-sulfopropyl)-ammonium hydroxide via 3-(trimethoxysilyl)propyl methacrylate. The columns were evaluated under isocratic conditions in hydrophilic interaction liquid chromatography. The best separation of amino acids was obtained on the monolithic column prepared by a stepwise modification procedure where the modification step was repeated four times. The mixture of fifteen amino acids was separated within 13 min using the mobile phase consisting of 75% acetonitrile and 25% 5 mmol/L ammonium acetate at pH 4.5.
Collapse
|
48
|
Jornet-Martínez N, Ortega-Sierra A, Verdú-Andrés J, Herráez-Hernández R, Campíns-Falcó P. Analysis of Contact Traces of Cannabis by In-Tube Solid-Phase Microextraction Coupled to Nanoliquid Chromatography. Molecules 2018; 23:molecules23092359. [PMID: 30223565 PMCID: PMC6225310 DOI: 10.3390/molecules23092359] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2018] [Revised: 09/06/2018] [Accepted: 09/13/2018] [Indexed: 01/08/2023] Open
Abstract
Because of its inherent qualities, in-tube solid-phase microextraction (IT-SPME) coupled on-line to nanoliquid chromatography (nanoLC) can be a very powerful tool to address the new challenges of analytical laboratories such as the analysis of traces of complex samples. This is the case of the detection of contact traces of drugs, especially cannabis. The main difficulties encountered in the analysis of traces of cannabis plants on surfaces are the low amount of sample available (typically < 1 mg), the complexity of the matrix, and the low percentages of cannabinoic compounds in the samples. In this work, a procedure is described for the detection of residues of cannabis on different surfaces based on the responses obtained by IT-SPME coupled to nanoLC with UV diode array detection (DAD) for the cannabinoids Δ9-tetrahydrocannabinol (THC), cannabidiol (CBD), and cannabinol (CBN); the proposed conditions can also be applied for quantitative purposes through the measurement of the percentage of THC, the most abundant cannabinoid in plants. The method is based on collecting the suspected drug samples with cotton swabs, followed by the extraction of the target compounds by ultrasound assisted extraction. The extracts are then separated and processed by IT-SPME-nanoLC. The proposed approach has been applied to the detection of traces of cannabis in different kind of items (plastic bags, office paper, aluminum foil, cotton cloths, and hand skin). Sample amounts as low as 0.08 mg have been collected and analysed for THC. The selectivity and effect of the storage conditions on the levels of THC have also been evaluated. The percentages of THC in the samples typically ranged from 0.6% to 2.8%, which means that amounts of this compound as low as 1–2 µg were adequately detected and quantified. For the first time, the reliability of IT-SPME-nanoLC for the analysis of complex matrices such as cannabis plant extracts has been demonstrated.
Collapse
Affiliation(s)
- Neus Jornet-Martínez
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| | - Adrián Ortega-Sierra
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| | - Jorge Verdú-Andrés
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| | - Rosa Herráez-Hernández
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| | - Pilar Campíns-Falcó
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| |
Collapse
|
49
|
Drevinskas T, Stankevičius M, Bimbiraitė-Survilienė K, Naujokaitytė G, Kaškonienė V, Kondrotienė K, Šernienė L, Kornyšova O, Malakauskas M, Maruška A. Optimization of a capillary zone electrophoresis-contactless conductivity detection method for the determination of nisin. Electrophoresis 2018; 39:2425-2430. [PMID: 29935020 DOI: 10.1002/elps.201800143] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 06/04/2018] [Accepted: 06/14/2018] [Indexed: 12/23/2022]
Abstract
Determination of natural preservatives using electrophoretic or chromatographic techniques in fermented milk products is a complex task due to the following reasons: (i) the concentrations of the analytes can be below the detection limits, (ii) complex matrix and comigrating/coeluting compounds in the sample can interfere with the analytes of the interest, (iii) low recovery of the analytes, and (iv) the necessity of complex sample preparation. The aim of this study was to apply capillary zone electrophoresis coupled with contactless conductivity detection for the separation and determination of nisin in fermented milk products. In this work, separation and determination of natural preservative-nisin in fermented milk products is described. Optimized conditions using capillary zone electrophoresis coupled with capacitance-to-digital technology based contactless conductivity detector and data conditioning, which filter the noise of the electropherogram adaptively to the peak migration time, allowed precise, accurate, sensitive (limit of quantification: 0.02 μg/mL), and most importantly requiring very minute sample preparation, determination of nisin. Sample preparation includes following steps: (i) extraction/dilution and (ii) centrifugation. This method was applied for the determination of nisin in real samples, i.e. fermented milk products. The values of different nisin forms were ranging from 0.056 ± 0.003 μg/mL to 9.307 ± 0.437 μg/g.
Collapse
Affiliation(s)
- Tomas Drevinskas
- Instrumental Analysis Open Access Centre, Faculty of Natural Sciences, Vytautas Magnus University, Kaunas, Lithuania
| | - Mantas Stankevičius
- Instrumental Analysis Open Access Centre, Faculty of Natural Sciences, Vytautas Magnus University, Kaunas, Lithuania
| | | | - Gintarė Naujokaitytė
- Instrumental Analysis Open Access Centre, Faculty of Natural Sciences, Vytautas Magnus University, Kaunas, Lithuania
| | - Vilma Kaškonienė
- Instrumental Analysis Open Access Centre, Faculty of Natural Sciences, Vytautas Magnus University, Kaunas, Lithuania
| | - Kristina Kondrotienė
- Department of Food Safety and Quality, Veterinary Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Loreta Šernienė
- Department of Food Safety and Quality, Veterinary Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Olga Kornyšova
- Instrumental Analysis Open Access Centre, Faculty of Natural Sciences, Vytautas Magnus University, Kaunas, Lithuania
| | - Mindaugas Malakauskas
- Department of Food Safety and Quality, Veterinary Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Audrius Maruška
- Instrumental Analysis Open Access Centre, Faculty of Natural Sciences, Vytautas Magnus University, Kaunas, Lithuania
| |
Collapse
|
50
|
Pires F, Otálora JAB, Bottoli CBG. New stationary phase for capillary liquid chromatography based on polydimethylsiloxane immobilized onto a Monolithic Silica Support. SEPARATION SCIENCE PLUS 2018. [DOI: 10.1002/sscp.201800033] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Fabiane Pires
- Institute of Chemistry; University of Campinas - UNICAMP; Campinas SP Brazil
| | | | | |
Collapse
|