1
|
Réveillon D, Georges des Aulnois M, Savar V, Robert E, Caruana AMN, Briand E, Bormans M. Extraction and analysis by liquid chromatography - tandem mass spectrometry of intra- and extracellular microcystins and nodularin to study the fate of cyanobacteria and cyanotoxins across the freshwater-marine continuum. Toxicon 2024; 237:107551. [PMID: 38070753 DOI: 10.1016/j.toxicon.2023.107551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 11/27/2023] [Accepted: 12/02/2023] [Indexed: 12/24/2023]
Abstract
The presence of microcystins (MCs) is increasingly being reported in coastal areas worldwide. To provide reliable data regarding this emerging concern, reproducible and accurate methods are required to quantify MCs in salt-containing samples. Herein, we characterized methods of extraction and analysis by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) for nine MCs and one nodularin (NOD) variants in both cyanobacteria (intracellular) and dissolved forms (extracellular). Different approaches have been used to cope with salinity for the extraction of dissolved MCs but none assessed solid phase extraction (SPE) so far. It was found that salt had negligible effect on the SPE recovery of dissolved MCs using the C18 cartridge while an overestimation up to 67% was noted for some variants with a polymeric sorbent. The limits of detection (LOD) and quantification (LOQ) were 1.0-22 and 5.5-124 pg on column for the intracellular toxins, while 0.05-0.81 and 0.13-2.4 ng/mL were obtained for dissolved toxins. Extraction recoveries were excellent for intracellular (89-121%) and good to excellent for extracellular cyanotoxins (73-102%) while matrix effects were considered neglectable (<12% for 16/20 toxin-matrix combinations), except for the two MC-RR variants. The strategy based on the application of a corrective factor to compensate for losses proved useful as the accuracy was satisfactory (73-117% for intra- and 81-139% for extracellular cyanotoxins, bias <10% for 46/60 conditions, with a few exceptions), with acceptable precisions (intra- and inter-days variabilities <11%). We then applied this method on natural colonies of Microcystis spp. subjected to a salt shock, mimicking their estuarine transfer, in order to assess their survival and to quantify their toxins. The colonies of Microcystis spp. had both their growth and photosynthetic activity impaired at salinities from 10, while toxins remained mainly intracellular (>76%) even at salinity 20, suggesting a potential health risk and contamination of estuarine organisms.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Myriam Bormans
- University of Rennes, CNRS, Ecobio UMR, 6553, Rennes, France
| |
Collapse
|
2
|
Xie Q, Xu Z, Huang G, Lin C, Lin X. Bioinspired polydopamine-mediated metal-organic framework click-grafting aptamers functionalized fabric for highly-specific recognition of microcystin-leucine arginine. J Chromatogr A 2023; 1688:463728. [PMID: 36566571 DOI: 10.1016/j.chroma.2022.463728] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 12/07/2022] [Accepted: 12/17/2022] [Indexed: 12/23/2022]
Abstract
Fabricating functional electrospun nanofiber coating for highly selective extraction of microcystin-LR (MC-LR) was of significant importance for water-safety monitoring. Herein, a novel MOF@aptamer functionalized nanofabric was presented via a facile and reliable strategy integrating polydopamine (PDA) mediation and thiol-ene chemistry and applied for specific recognition of the MC-LR model analyte. Using polydopamine (PDA) as the mediating layer, vinyl-UiO-66 MOF was grown in situ, followed by post-synthetic modification (PSM) of Zr4+ with vinyl phosphate and rapid UV-initiated click reaction of aptamers. Uniform deposition of Zr-based MOF (vinyl-UiO-66) on the nanofibers was directly produced, and the tedious co-electrospinning process was abandoned to prevent the aggregation and encapsulation of MOF. Via an efficient "thiol-ene" chemistry, massive thiol-terminated aptamers were grafted on MOF within one step under friendly conditions, rather than the time-consuming nanoparticle adsorption or unfriendly covalent chemical reactions. As a result, the robust MOF@aptamer-coated nano-fabrics were obtained, and a highly selective performance towards MC-LR was illustrated with a limit of detection (LOD) at 0.002 ng/mL, good precision (CV<8.3%), good repeatability (2.2∼6.0%) when coupled with LC-MS. Almost 1∼2 orders of magnitude higher detection sensitivity was exhibited than that of the common non-specific SPE/SPME fiber reported so far. Applied to water samples, the good matrix-resistance ability, and acceptable recovery yields were achieved with high specificity. This strategy might provide a rapid and friendly protocol to efficiently fabricate MOF@aptamer functionalized nano-fabrics through electrospinning and interfacial "thiol-ene" chemistry for highly-selective microextraction.
Collapse
Affiliation(s)
- Qian Xie
- Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety in Fujian Province, Fuzhou University, Fuzhou, 350108, People's Republic of China; Institute of Analytical Technology and Smart Instruments, Xiamen Huaxia University, Xiamen, 361024, People's Republic of China
| | - Zhiqun Xu
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China; Department of Medical Science and Technology, Suzhou Chien-shiung Institute of Technology, Taicang, 215411, People's Republic of China
| | - Guobin Huang
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Chenchen Lin
- Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety in Fujian Province, Fuzhou University, Fuzhou, 350108, People's Republic of China; Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China.
| | - Xucong Lin
- Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety in Fujian Province, Fuzhou University, Fuzhou, 350108, People's Republic of China; Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, People's Republic of China.
| |
Collapse
|
3
|
Yeo S, Yoon I, Lee WK. Design and Characterisation of pH-Responsive Photosensitiser-Loaded Nano-Transfersomes for Enhanced Photodynamic Therapy. Pharmaceutics 2022; 14:pharmaceutics14010210. [PMID: 35057105 PMCID: PMC8781809 DOI: 10.3390/pharmaceutics14010210] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 01/13/2022] [Accepted: 01/13/2022] [Indexed: 02/01/2023] Open
Abstract
Photodynamic therapy (PDT) is a non-invasive and tumour-specific therapy. Photosensitizers (PSs) (essential ingredients in PDT) aggregate easily owing to their lipophilic properties. The aim of this study was to synthesise a PS (methyl pheophorbide a, MPa) and design a biocompatible lipid-based nanocarrier to improve its bioavailability and pharmacological effects. MPa-loaded nano-transfersomes were fabricated by sonication. The characteristics of synthesised PS and nano-transfersomes were assessed. The effects of PDT were evaluated by 1,3-diphenylisobenzofuran assay and by measuring photo-cytotoxicity against HeLa and A549 cell lines. The mean particle size and zeta potential for nano-transfersomes ranged from 95.84 to 267.53 nm and −19.53 to −45.08 mV, respectively. Nano-transfersomes exhibited sustained drug release for 48 h in a physiological environment (as against burst release in an acidic environment), which enables its use as a pH-responsive drug release system in PDT with enhanced photodynamic activity and reduced side effects. The formulations showed light cytotoxicity, but no dark toxicity, which meant that light irradiation resulted in anti-cancer effects. Additionally, formulations with the smallest size exhibited photodynamic activity to a larger extent than those with the highest loading capacity or free MPa. These results suggest that our MPa-loaded nano-transfersome system is a promising anti-cancer strategy for PDT.
Collapse
Affiliation(s)
- Sooho Yeo
- Correspondence: (S.Y.); (I.Y.); (W.K.L.); Tel.: +82-55-320-3871 (S.Y. & I.Y.); +82-55-320-3875 (W.K.L.); Fax: +82-55-321-7034 (S.Y. & I.Y.); +82-55-320-3875 (W.K.L.)
| | - Il Yoon
- Correspondence: (S.Y.); (I.Y.); (W.K.L.); Tel.: +82-55-320-3871 (S.Y. & I.Y.); +82-55-320-3875 (W.K.L.); Fax: +82-55-321-7034 (S.Y. & I.Y.); +82-55-320-3875 (W.K.L.)
| | - Woo Kyoung Lee
- Correspondence: (S.Y.); (I.Y.); (W.K.L.); Tel.: +82-55-320-3871 (S.Y. & I.Y.); +82-55-320-3875 (W.K.L.); Fax: +82-55-321-7034 (S.Y. & I.Y.); +82-55-320-3875 (W.K.L.)
| |
Collapse
|
4
|
Li J, Feng M, Yu X. Rapid detection of mcyG gene of microcystins producing cyanobacteria in water samples by recombinase polymerase amplification combined with lateral flow strips. JOURNAL OF WATER AND HEALTH 2021; 19:907-917. [PMID: 34874899 DOI: 10.2166/wh.2021.091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Nowadays, cyanobacteria blooms and microcystins (MCs) pollution are threatening water safety and public health. In this study, a rapid detection method was established for detecting MCs producing cyanobacteria. The MC synthesis gene mcyG was measured through recombinase polymerase amplification combined with lateral flow strips (LF-RPA) technology. The target gene mcyG was amplified at a temperature range of 37-45 °C, and the amplification time to detect mcyG was only 15 min at 37 °C. The optimal reaction conditions were confirmed using single dependent variable experiments, suggesting that the best probe dosage for 50 μL of the reaction mixture was 0.2 μL, the best dilution ratio of products was 1/100, and the best loading volume was 10 μL. The specificity test proved that the LF-RPA assay could distinguish MCs producing cyanobacteria from nontoxic algae well. Within 35 min of amplification time, the detection limit of the LF-RPA assay was 103 copies/mL mcyG and 104 cells/mL Microcystis aeruginosa FACHB-905. Overall, the LF-RPA assay could detect MCs producing cyanobacteria in water samples quickly and accurately, and it has a great promise to be applied for monitoring the MCs producing cyanobacteria blooms in natural waters.
Collapse
Affiliation(s)
- Jingjing Li
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Mingbao Feng
- College of the Environment & Ecology, Xiamen University, Xiamen 361005, China E-mail:
| | - Xin Yu
- College of the Environment & Ecology, Xiamen University, Xiamen 361005, China E-mail:
| |
Collapse
|
5
|
Xing J, Zhang Z, Zheng R, Xu X, Mao L, Lu J, Shen J, Dai X, Yang Z. Simultaneous Detection of Seven Alternaria Toxins in Mixed Fruit Puree by Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry Coupled with a Modified QuEChERS. Toxins (Basel) 2021; 13:toxins13110808. [PMID: 34822592 PMCID: PMC8619939 DOI: 10.3390/toxins13110808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 11/11/2021] [Accepted: 11/11/2021] [Indexed: 11/25/2022] Open
Abstract
The presence of Alternaria toxins (ATs) in fruit purees may cause potential harm to the life and health of consumers. As time passes, ATs have become the key detection objects in this kind of food. Based on this, a novel and rapid method was established in this paper for the simultaneous detection of seven ATS (tenuazonic acid, alternariol, alternariol monomethyl ether, altenuene, tentoxin, altenusin, and altertoxin I) in mixed fruit purees using ultra-high performance liquid chromatography-tandem mass spectrometry. The sample was prepared using the modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method to complete the extraction and clean-up steps in one procedure. In this QuEChERS method, sample was extracted with water and acetonitrile (1.5% formic acid), then salted out with NaCl, separated on an ACQUITY UPLC BEH C18 with gradient elution by using acetonitrile and 0.1% formic acid aqueous as eluent, and detected by UPLC-MS/MS under positive (ESI+) and negative (ESI−) electrospray ionization and MRM models. Results showed that the seven ATs exhibited a good linearity in the concentration range of 0.5–200 ng/mL with R2 > 0.9925, and the limits of detection (LODs) of the instrument were in the range of 0.18–0.53 μg/kg. The average recoveries ranged from 79.5% to 106.7%, with the relative standard deviations (RSDs) no more than 9.78% at spiked levels of 5, 10, and 20 μg/kg for seven ATs. The established method was applied to the determination and analysis of the seven ATs in 80 mixed fruit puree samples. The results showed that ATs were detected in 31 of the 80 samples, and the content of ATs ranged from 1.32 μg/kg to 54.89 μg/kg. Moreover, the content of TeA was the highest in the detected samples (23.32–54.89 μg/kg), while the detection rate of Ten (24/31 samples) was higher than the other ATs. Furthermore, the other five ATs had similar and lower levels of contamination. The method established in this paper is accurate, rapid, simple, sensitive, repeatable, and stable, and can be used for the practical determination of seven ATs in fruit puree or other similar samples. Moreover, this method could provide theory foundation for the establishment of limit standard of ATs and provide a reference for the development of similar detection standard methods in the future.
Collapse
Affiliation(s)
- Jiali Xing
- Ningbo Academy of Product and Food Quality Inspection (Ningbo Fibre Inspection Institute), Ningbo 315048, China; (J.X.); (X.X.); (L.M.); (J.L.); (J.S.)
- College of Biological and Environmental Sciences, Zhejiang Wanli University, Ningbo 315100, China;
| | - Zigeng Zhang
- College of Life Sciences, China Jiliang University, Hangzhou 310018, China;
| | - Ruihang Zheng
- Ningbo Academy of Product and Food Quality Inspection (Ningbo Fibre Inspection Institute), Ningbo 315048, China; (J.X.); (X.X.); (L.M.); (J.L.); (J.S.)
- Correspondence: (R.Z.); (X.D.); Tel.: +86-574-89078647 (R.Z.); +86-574-89077478 (X.D.)
| | - Xiaorong Xu
- Ningbo Academy of Product and Food Quality Inspection (Ningbo Fibre Inspection Institute), Ningbo 315048, China; (J.X.); (X.X.); (L.M.); (J.L.); (J.S.)
| | - Lingyan Mao
- Ningbo Academy of Product and Food Quality Inspection (Ningbo Fibre Inspection Institute), Ningbo 315048, China; (J.X.); (X.X.); (L.M.); (J.L.); (J.S.)
| | - Jingping Lu
- Ningbo Academy of Product and Food Quality Inspection (Ningbo Fibre Inspection Institute), Ningbo 315048, China; (J.X.); (X.X.); (L.M.); (J.L.); (J.S.)
| | - Jian Shen
- Ningbo Academy of Product and Food Quality Inspection (Ningbo Fibre Inspection Institute), Ningbo 315048, China; (J.X.); (X.X.); (L.M.); (J.L.); (J.S.)
| | - Xianjun Dai
- College of Life Sciences, China Jiliang University, Hangzhou 310018, China;
- Correspondence: (R.Z.); (X.D.); Tel.: +86-574-89078647 (R.Z.); +86-574-89077478 (X.D.)
| | - Zhenfeng Yang
- College of Biological and Environmental Sciences, Zhejiang Wanli University, Ningbo 315100, China;
| |
Collapse
|
6
|
Hammad SF, Abdallah IA, Bedair A, Mansour FR. Homogeneous liquid-liquid extraction as an alternative sample preparation technique for biomedical analysis. J Sep Sci 2021; 45:185-209. [PMID: 34472701 DOI: 10.1002/jssc.202100452] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 08/26/2021] [Accepted: 08/27/2021] [Indexed: 12/12/2022]
Abstract
Liquid-liquid extraction is a widely used technique of sample preparation in biomedical analysis. In spite of the high pre-concentration capacities of liquid-liquid extraction, it suffers from a number of limitations including time and effort consumption, large organic solvent utilization, and poor performance in highly polar analytes. Homogeneous liquid-liquid extraction is an alternative sample preparation technique that overcomes some drawbacks of conventional liquid-liquid extraction, and allows employing greener organic solvents in sample treatment. In homogeneous liquid-liquid extraction, a homogeneous phase is formed between the aqueous sample and the water-miscible extractant, followed by chemically or physically induced phase separation. To form the homogeneous phase, aqueous samples are mixed with water-miscible organic solvents, water-immiscible solvents/cosolvents, surfactants, or smart polymers. Then, phase separation is induced chemically (adding salt, sugar, or buffer) or physically (changing temperature or pH). This mode is rapid, sustainable, and cost-effective in comparison with other sample preparation techniques. Moreover, homogeneous liquid-liquid extraction is more suitable for the extraction of delicate macromolecules such as enzymes, hormones, and proteins and it is more compatible with liquid chromatography with tandem mass spectrometry, which is a vital technique in metabolomics and proteomics. In this review, the principle, types, applications, automation, and technical aspects of homogeneous liquid-liquid extraction are discussed.
Collapse
Affiliation(s)
- Sherin F Hammad
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt
| | - Inas A Abdallah
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, Egypt
| | - Alaa Bedair
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, Egypt
| | - Fotouh R Mansour
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt.,Pharmaceutical Services Center, Faculty of Pharmacy, Tanta University, Tanta, Egypt
| |
Collapse
|
7
|
Kanu AB. Recent developments in sample preparation techniques combined with high-performance liquid chromatography: A critical review. J Chromatogr A 2021; 1654:462444. [PMID: 34380070 DOI: 10.1016/j.chroma.2021.462444] [Citation(s) in RCA: 56] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 07/21/2021] [Accepted: 07/24/2021] [Indexed: 12/29/2022]
Abstract
This review article compares and contrasts sample preparation techniques coupled with high-performance liquid chromatography (HPLC) and describes applications developed in biomedical, forensics, and environmental/industrial hygiene in the last two decades. The proper sample preparation technique can offer valued data for a targeted application when coupled to HPLC and a suitable detector. Improvements in sample preparation techniques in the last two decades have resulted in efficient extraction, cleanup, and preconcentration in a single step, thus providing a pathway to tackle complex matrix applications. Applications such as biological therapeutics, proteomics, lipidomics, metabolomics, environmental/industrial hygiene, forensics, glycan cleanup, etc., have been significantly enhanced due to improved sample preparation techniques. This review looks at the early sample preparation techniques. Further, it describes eight sample preparation technique coupled to HPLC that has gained prominence in the last two decades. They are (1) solid-phase extraction (SPE), (2) liquid-liquid extraction (LLE), (3) gel permeation chromatography (GPC), (4) Quick Easy Cheap Effective Rugged, Safe (QuEChERS), (5) solid-phase microextraction (SPME), (6) ultrasonic-assisted solvent extraction (UASE), and (7) microwave-assisted solvent extraction (MWASE). SPE, LLE, GPC, QuEChERS, and SPME can be used offline and online with HPLC. UASE and MWASE can be used offline with HPLC but have also been combined with the online automated techniques of SPE, LLE, GPC, or QuEChERS for targeted analysis. Three application areas of biomedical, forensics, and environmental/industrial hygiene are reviewed for the eight sample preparation techniques. Three hundred and twenty references on the eight sample preparation techniques published over the last two decades (2001-2021) are provided. Other older references were included to illustrate the historical development of sample preparation techniques.
Collapse
Affiliation(s)
- A Bakarr Kanu
- Department of Chemistry, Winston-Salem State University, Winston-Salem, NC 27110, United States.
| |
Collapse
|
8
|
Zheng C, Yin M, Su B, Peng A, Guo Z, Chen X, Chen X. A novel near-infrared light-responsive photoelectrochemical platform for detecting microcystin-LR in fish based on Ag2S cubes and plasmonic Au nanoparticles. Talanta 2021; 221:121447. [DOI: 10.1016/j.talanta.2020.121447] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 07/14/2020] [Accepted: 07/22/2020] [Indexed: 02/06/2023]
|
9
|
Pasupuleti RR, Gurrani S, Tsai PC, Ponnusamy VK. Novel Salt-Assisted Liquid-Liquid Microextraction Technique for Environmental, Food, and Biological Samples Analysis Applications: A Review. CURR ANAL CHEM 2020. [DOI: 10.2174/1573411017999201228212537] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background::
Sample preparation has gained significant recognition in the chemical analysis workflow. Substantial efforts have been made to simplify the comprehensive process of sample preparation that is focused on green sample preparation methodology, including the miniaturization of extraction method, elimination of the sample pre-treatment as well as the post-treatment steps, elimination of toxic as well as hazardous organic solvent consumption, reduction in sample volume requirements, reducing the extraction time, maximization of the extraction efficiency and possible automation.
Methods::
Among various microextraction processes, liquid-phase microextraction (LPME) is most abundantly used in the extraction of the target analytes. The salting-out phenomenon has been introduced into the LPME procedure and has been raised as a new technique called the ‘Salt-Assisted Liquid-Liquid Microextraction (SALLME)’. The principle is based on decreasing the solubility of less polar solvent or analyte with an increase in the concentration of the salt in aqueous solution leading to two-phase separation.
Conclusion::
SALLME proved to be a simple, rapid, and cost-effective sample preparation technique for the efficient extraction and preconcentration of organic and inorganic contaminants from various sample matrices, including environmental, biological, and food samples. SALLME exhibits higher extraction efficiency and recovery and compatible with multiple analytical instruments. This review provides an overview of developments in SALLME technique and its applications to till date.
Collapse
Affiliation(s)
- Raghavendra Rao Pasupuleti
- Department of Medicinal and Applied Chemistry, Nano and Green Analytical Lab, Kaohsiung Medical University (KMU), Kaohsiung City-807,, Taiwan
| | - Swapnil Gurrani
- Research Center for Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City-807,, Taiwan
| | - Pei-Chien Tsai
- Department of Medicinal and Applied Chemistry, Nano and Green Analytical Lab, Kaohsiung Medical University (KMU), Kaohsiung City-807,, Taiwan
| | - Vinoth Kumar Ponnusamy
- Department of Chemistry, National Sun Yat-sen University (NSYSU), Kaohsiung City-804,, Taiwan
| |
Collapse
|
10
|
Homogeneous liquid liquid extraction using salt as mass separating agent for the ultra high pressure liquid chromatographic determination of doxorubicin in human urine. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105260] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
11
|
Massey IY, Wu P, Wei J, Luo J, Ding P, Wei H, Yang F. A Mini-Review on Detection Methods of Microcystins. Toxins (Basel) 2020; 12:E641. [PMID: 33020400 PMCID: PMC7601875 DOI: 10.3390/toxins12100641] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2020] [Revised: 09/28/2020] [Accepted: 09/30/2020] [Indexed: 12/14/2022] Open
Abstract
Cyanobacterial harmful algal blooms (CyanoHABs) produce microcystins (MCs) which are associated with animal and human hepatotoxicity. Over 270 variants of MC exist. MCs have been continually studied due of their toxic consequences. Monitoring water quality to assess the presence of MCs is of utmost importance although it is often difficult because CyanoHABs may generate multiple MC variants, and their low concentration in water. To effectively manage and control these toxins and prevent their health risks, sensitive, fast, and reliable methods capable of detecting MCs are required. This paper aims to review the three main analytical methods used to detect MCs ranging from biological (mouse bioassay), biochemical (protein phosphatase inhibition assay and enzyme linked immunosorbent assay), and chemical (high performance liquid chromatography, liquid chromatography-mass spectrometry, high performance capillary electrophoresis, and gas chromatography), as well as the newly emerging biosensor methods. In addition, the current state of these methods regarding their novel development and usage, as well as merits and limitations are presented. Finally, this paper also provides recommendations and future research directions towards method application and improvement.
Collapse
Affiliation(s)
- Isaac Yaw Massey
- Xiangya School of Public Health, Central South University, Changsha 410078, China; (I.Y.M.); (P.W.); (J.W.); (J.L.); (P.D.)
| | - Pian Wu
- Xiangya School of Public Health, Central South University, Changsha 410078, China; (I.Y.M.); (P.W.); (J.W.); (J.L.); (P.D.)
| | - Jia Wei
- Xiangya School of Public Health, Central South University, Changsha 410078, China; (I.Y.M.); (P.W.); (J.W.); (J.L.); (P.D.)
| | - Jiayou Luo
- Xiangya School of Public Health, Central South University, Changsha 410078, China; (I.Y.M.); (P.W.); (J.W.); (J.L.); (P.D.)
| | - Ping Ding
- Xiangya School of Public Health, Central South University, Changsha 410078, China; (I.Y.M.); (P.W.); (J.W.); (J.L.); (P.D.)
| | - Haiyan Wei
- Department of Occupational Medicine and Environmental Toxicology, School of Public Health, Nantong University, Nantong 226019, China
| | - Fei Yang
- Xiangya School of Public Health, Central South University, Changsha 410078, China; (I.Y.M.); (P.W.); (J.W.); (J.L.); (P.D.)
- School of Public Health, University of South China, Hengyang 421001, China
| |
Collapse
|
12
|
Zhang JH, Zhang ZT, Ou YJ, Zhang F, Meng J, Wang G, Fang ZL, Li Y. Red-emitting GSH-Cu NCs as a triplet induced quenched fluorescent probe for fast detection of thiol pollutants. NANOSCALE 2020; 12:19429-19437. [PMID: 32959864 DOI: 10.1039/d0nr04645k] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Thiol compounds exist widely on the Earth and have certain significance in the fields of the circulation of the sulfur element and industrial production. However, the odor and biological toxicity of thiol compounds make them pollutants that seriously threaten the environmental safety and the living quality of human. In this study, a novel triplet induced fluorescence "turn-off" strategy was designed for the detection of thiol pollutants via a glutathione-stabilized copper nanocluster (GSH-Cu NC) probe. The as-prepared GSH-Cu NCs not only have small size and good water-solubility, but also exhibit strong red-emitting fluorescence at 630 nm, which could be quenched quantitatively with the increase of the concentration of thiol pollutants. So they were employed to detect thioglycolic acid (TGA), 3-mercaptopropionic acid (MPA), 2-mercaptoethanol (ME) and 2-(diethylamino)ethanethiol (2-AT) in a wide linear range of 1-100 μM with detection limits of 0.73 μM, 0.43 μM, 0.37 μM, and 0.69 μM, respectively. This method was successfully applied to detect the above thiol pollutants in lake water with good recoveries. Moreover, their further application was also expanded as luminous test strips based on the excellent fluorescence characteristics of GSH-Cu NCs for fast real-time detection of thiol pollutants.
Collapse
Affiliation(s)
- Jun-Hua Zhang
- Tianjin Key laboratory of Structure and Performance for Functional Molecules, MOE Key Laboratory of Inorganic-Organic Hybrid Functional Material Chemistry, College of Chemistry, Tianjin Normal University, 393 Binshui West Road, Tianjin 300387, PR China. and State Environmental Protection Key Laboratory of Odor Pollution Control, Tianjin Academy of Environmental Sciences, Tianjin 300191, PR China
| | - Zi-Tong Zhang
- Tianjin Key laboratory of Structure and Performance for Functional Molecules, MOE Key Laboratory of Inorganic-Organic Hybrid Functional Material Chemistry, College of Chemistry, Tianjin Normal University, 393 Binshui West Road, Tianjin 300387, PR China.
| | - Yang-Jing Ou
- Tianjin Key laboratory of Structure and Performance for Functional Molecules, MOE Key Laboratory of Inorganic-Organic Hybrid Functional Material Chemistry, College of Chemistry, Tianjin Normal University, 393 Binshui West Road, Tianjin 300387, PR China.
| | - Fei Zhang
- Tianjin Key laboratory of Structure and Performance for Functional Molecules, MOE Key Laboratory of Inorganic-Organic Hybrid Functional Material Chemistry, College of Chemistry, Tianjin Normal University, 393 Binshui West Road, Tianjin 300387, PR China. and State Environmental Protection Key Laboratory of Odor Pollution Control, Tianjin Academy of Environmental Sciences, Tianjin 300191, PR China
| | - Jie Meng
- State Environmental Protection Key Laboratory of Odor Pollution Control, Tianjin Academy of Environmental Sciences, Tianjin 300191, PR China
| | - Gen Wang
- State Environmental Protection Key Laboratory of Odor Pollution Control, Tianjin Academy of Environmental Sciences, Tianjin 300191, PR China
| | - Zhao-Lin Fang
- Tianjin Key laboratory of Structure and Performance for Functional Molecules, MOE Key Laboratory of Inorganic-Organic Hybrid Functional Material Chemistry, College of Chemistry, Tianjin Normal University, 393 Binshui West Road, Tianjin 300387, PR China.
| | - Yan Li
- Tianjin Key laboratory of Structure and Performance for Functional Molecules, MOE Key Laboratory of Inorganic-Organic Hybrid Functional Material Chemistry, College of Chemistry, Tianjin Normal University, 393 Binshui West Road, Tianjin 300387, PR China.
| |
Collapse
|