1
|
Alvarez-Mora I, Arturi K, Béen F, Buchinger S, El Mais AER, Gallampois C, Hahn M, Hollender J, Houtman C, Johann S, Krauss M, Lamoree M, Margalef M, Massei R, Brack W, Muz M. Progress, applications, and challenges in high-throughput effect-directed analysis for toxicity driver identification - is it time for HT-EDA? Anal Bioanal Chem 2024:10.1007/s00216-024-05424-4. [PMID: 38992177 DOI: 10.1007/s00216-024-05424-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 06/21/2024] [Accepted: 06/24/2024] [Indexed: 07/13/2024]
Abstract
The rapid increase in the production and global use of chemicals and their mixtures has raised concerns about their potential impact on human and environmental health. With advances in analytical techniques, in particular, high-resolution mass spectrometry (HRMS), thousands of compounds and transformation products with potential adverse effects can now be detected in environmental samples. However, identifying and prioritizing the toxicity drivers among these compounds remain a significant challenge. Effect-directed analysis (EDA) emerged as an important tool to address this challenge, combining biotesting, sample fractionation, and chemical analysis to unravel toxicity drivers in complex mixtures. Traditional EDA workflows are labor-intensive and time-consuming, hindering large-scale applications. The concept of high-throughput (HT) EDA has recently gained traction as a means of accelerating these workflows. Key features of HT-EDA include the combination of microfractionation and downscaled bioassays, automation of sample preparation and biotesting, and efficient data processing workflows supported by novel computational tools. In addition to microplate-based fractionation, high-performance thin-layer chromatography (HPTLC) offers an interesting alternative to HPLC in HT-EDA. This review provides an updated perspective on the state-of-the-art in HT-EDA, and novel methods/tools that can be incorporated into HT-EDA workflows. It also discusses recent studies on HT-EDA, HT bioassays, and computational prioritization tools, along with considerations regarding HPTLC. By identifying current gaps in HT-EDA and proposing new approaches to overcome them, this review aims to bring HT-EDA a step closer to monitoring applications.
Collapse
Affiliation(s)
- Iker Alvarez-Mora
- Department of Exposure Science, Helmholtz Centre for Environmental Research, UFZ, Leipzig, Germany.
- Research Centre for Experimental Marine Biology and Biotechnology (PIE), University of the Basque Country (UPV/EHU), Plentzia, Basque Country, Spain.
| | - Katarzyna Arturi
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| | - Frederic Béen
- KWR Water Research Institute, Nieuwegein, the Netherlands
- Chemistry for Environment and Health, Amsterdam Institute for Life and Environment (A-LIFE), Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - Sebastian Buchinger
- Department of Biochemistry and Ecotoxicology, Federal Institute of Hydrology (BfG), Koblenz, Germany
| | | | | | - Meike Hahn
- Department of Biochemistry and Ecotoxicology, Federal Institute of Hydrology (BfG), Koblenz, Germany
| | - Juliane Hollender
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
- Institute of Biogeochemistry and Pollutant Dynamics, ETH Zurich, Zürich, Switzerland
| | - Corine Houtman
- Chemistry for Environment and Health, Amsterdam Institute for Life and Environment (A-LIFE), Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
- The Water Laboratory, Haarlem, the Netherlands
| | - Sarah Johann
- Department of Evolutionary Ecology and Environmental Toxicology, Goethe University Frankfurt, Frankfurt Am Main, Germany
| | - Martin Krauss
- Department of Exposure Science, Helmholtz Centre for Environmental Research, UFZ, Leipzig, Germany
| | - Marja Lamoree
- Chemistry for Environment and Health, Amsterdam Institute for Life and Environment (A-LIFE), Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - Maria Margalef
- Chemistry for Environment and Health, Amsterdam Institute for Life and Environment (A-LIFE), Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - Riccardo Massei
- Department of Monitoring and Exploration Technologies, Research Data Management Team (RDM), Helmholtz Centre for Environmental Research, UFZ, Leipzig, Germany
- Department of Ecotoxicology, Group of Integrative Toxicology (iTox), Helmholtz Centre for Environmental Research, UFZ, Leipzig, Germany
| | - Werner Brack
- Department of Exposure Science, Helmholtz Centre for Environmental Research, UFZ, Leipzig, Germany
- Department of Evolutionary Ecology and Environmental Toxicology, Goethe University Frankfurt, Frankfurt Am Main, Germany
| | - Melis Muz
- Department of Exposure Science, Helmholtz Centre for Environmental Research, UFZ, Leipzig, Germany
| |
Collapse
|
2
|
Shang HB, Zhang JM, An Z, Li XQ, Li X, Wu L, Li D. Reversible polarity-switch of thin-layer chromatography by photo-induction with multi-regulation in spatial dimension. Talanta 2024; 271:125654. [PMID: 38224659 DOI: 10.1016/j.talanta.2024.125654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 12/05/2023] [Accepted: 01/08/2024] [Indexed: 01/17/2024]
Abstract
Generally, thin-layer chromatography always undertakes the indispensable role in rapid screening and identification of specific compounds. Stationary phase is the core part of thin-layer chromatography with fixed property, which leading to the limitations of separation mode of only regulating the composition of mobile phase. This work was an attempt to fabricate the unique photosensitive thin-layer chromatography to make up the above major drawback. 4-[3-(Triethoxysilyl)propoxy]azobenzene (azo-PTES) was synthesized as photosensitive modifier to fabricate the photosensitive stationary phase, and the transformation of cis-trans structure of azo-PTES proceeds along with polarity difference under 365 nm and 473 nm irradiation. Based on this, the proposed photosensitive thin-layer chromatography shows the reversible switch of polarity of stationary phase by photoinduction, followed by the deserved reversible separation behavior. Furthermore, multi-regulation in spatial dimension was achieved based on the high freedom of spatial regulation of photoinduction, which brings about the integration of stationary phase with different polarity, just by photoinduction. The concept of photosensitive thin-layer chromatography provides new idea for improving separation efficiency and developing multi-dimensional thin-layer chromatography on the one plate.
Collapse
Affiliation(s)
- Hai-Bo Shang
- Interdisciplinary Program of Biological Functional Molecules, College of Integration Science, Yanbian University, Yanji City, 133002, Jilin Province, China; Department of Chemistry, National Demonstration Centre for Experimental Chemistry Education, Yanbian University, Yanji City, 133002, Jilin Province, China
| | - Jie-Min Zhang
- Interdisciplinary Program of Biological Functional Molecules, College of Integration Science, Yanbian University, Yanji City, 133002, Jilin Province, China
| | - Zhengjiu An
- Interdisciplinary Program of Biological Functional Molecules, College of Integration Science, Yanbian University, Yanji City, 133002, Jilin Province, China
| | - Xin-Qi Li
- Department of Chemistry, National Demonstration Centre for Experimental Chemistry Education, Yanbian University, Yanji City, 133002, Jilin Province, China
| | - Xia Li
- Interdisciplinary Program of Biological Functional Molecules, College of Integration Science, Yanbian University, Yanji City, 133002, Jilin Province, China
| | - Lixin Wu
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, China.
| | - Donghao Li
- Interdisciplinary Program of Biological Functional Molecules, College of Integration Science, Yanbian University, Yanji City, 133002, Jilin Province, China; Department of Chemistry, National Demonstration Centre for Experimental Chemistry Education, Yanbian University, Yanji City, 133002, Jilin Province, China.
| |
Collapse
|
3
|
Müller I, Gulde A, Morlock GE. Bioactive profiles of edible vegetable oils determined using 10D hyphenated comprehensive high-performance thin-layer chromatography (HPTLC×HPTLC) with on-surface metabolism (nanoGIT) and planar bioassays. Front Nutr 2023; 10:1227546. [PMID: 37810920 PMCID: PMC10556687 DOI: 10.3389/fnut.2023.1227546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 08/04/2023] [Indexed: 10/10/2023] Open
Abstract
Introduction Vegetable oils rich in unsaturated fatty acids are assumed to be safe and even healthy for consumers though lipid compositions of foods vary naturally and are complex considering the wealth of minor compounds down to the trace level. Methods The developed comprehensive high-performance thin-layer chromatography (HPTLC×HPTLC) method including the on-surface metabolization (nanoGIT) and bioassay detection combined all steps on the same planar surface. The pancreatic lipolysis (intestinal phase) experiment and the subsequent analysis of the fatty acid composition including its effect-directed detection using a planar bioassay was performed without elaborate sample preparation or fractionation to ensure sample integrity. Thus, no sample part was lost, and the whole sample was studied on a single surface regarding all aspects. This made the methodology as well as technology miniaturized, lean, all-in-one, and very sustainable. Results and discussion To prioritize important active compounds including their metabolism products in the complex oil samples, the nanoGIT method was used to examine the pancreatic lipolysis of nine different vegetable oils commonly used in the kitchen and food industry, e.g., canola oil, flaxseed oil, hemp oil, walnut oil, soybean oil, sunflower oil, olive oil, coconut oil, and palm oil. The digested oils revealed antibacterial and genotoxic effects, which were assigned to fatty acids and oxidized species via high-resolution tandem mass spectrometry (HRMS/MS). This finding reinforces the importance of adding powerful techniques to current analytical tools. The 10D hyphenated nanoGIT-HPTLC×HPTLC-Vis/FLD-bioassay-heart cut-RP-HPLC-DAD-HESI-HRMS/MS has the potential to detect any potential hazard due to digestion/metabolism, improving food safety and understanding on the impact of complex samples.
Collapse
Affiliation(s)
- Isabel Müller
- Institute of Nutritional Science, Chair of Food Science, as well as Interdisciplinary Research Centre for Biosystems, Land Use and Nutrition, Justus Liebig University Giessen, Giessen, Germany
| | - Alexander Gulde
- Institute of Nutritional Science, Chair of Food Science, as well as Interdisciplinary Research Centre for Biosystems, Land Use and Nutrition, Justus Liebig University Giessen, Giessen, Germany
| | - Gertrud E. Morlock
- Institute of Nutritional Science, Chair of Food Science, as well as Interdisciplinary Research Centre for Biosystems, Land Use and Nutrition, Justus Liebig University Giessen, Giessen, Germany
- Center for Sustainable Food Systems, Justus Liebig University Giessen, Giessen, Germany
| |
Collapse
|
4
|
Poole CF. Sample preparation for planar chromatography. J Sep Sci 2023; 46:e2300071. [PMID: 36965178 DOI: 10.1002/jssc.202300071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 03/18/2023] [Accepted: 03/19/2023] [Indexed: 03/27/2023]
Abstract
High-performance thin-layer chromatography has favorable properties for high-throughput separations with a high matrix tolerance. Sample preparation, however, is sometimes required to control specific matrix interferences and to enhance the detectability of target compounds. Trends in contemporary applications have shifted from absorbance and fluorescence detection to methods employing bioassays and mass spectrometry. Traditional methods (shake-flask, heat at reflux, Soxhlet, and hydrodistillation) are being challenged by automated instrumental approaches (ultrasound-assisted and microwave-assisted solvent extraction, pressurized liquid extraction, and supercritical fluid extraction) and the quick, easy cheap, efficient, rugged, and safe extraction method for faster and streamlined sample processing. Liquid-liquid extraction remains the most widely used approach for sample clean-up with increasing competition from solid-phase extraction. On-layer sample, clean-up by planar solid-phase extraction is increasingly used for complex samples and in combination with heart-cut multimodal systems. The automated spray-on sample applicator, the elution head interface, biological detection of target and non-target compounds, and straightforward mass spectrometric detection are highlighted as the main factors directing current interest toward faster and simpler sample workflows, analysis of more complex samples, and the determination of minor contaminants requiring high concentration factors.
Collapse
Affiliation(s)
- Colin F Poole
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
| |
Collapse
|
5
|
Wilson ID, Poole CF. Planar chromatography - Current practice and future prospects. J Chromatogr B Analyt Technol Biomed Life Sci 2023; 1214:123553. [PMID: 36495686 DOI: 10.1016/j.jchromb.2022.123553] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 11/01/2022] [Accepted: 11/24/2022] [Indexed: 11/29/2022]
Abstract
Planar chromatography, in the form of thin-layer or high-performance thin-layer chromatography (TLC, HPTLC), continues to provide a robust and widely used separation technique. It is unrivaled as a simple and rapid qualitative method for mixture analysis, or for finding bioactive components in mixtures. The format of TLC/HPTLC also provides a unique method for preserving the separation, enabling further investigation of components of interest (including quantification/structure determination) separated in both time and space from the original analysis. The current practice of planar chromatography and areas of development of the technology are reviewed and promising future directions in the use of TLC/HPTLC are outlined.
Collapse
Affiliation(s)
- Ian D Wilson
- Division of Systems Medicine, Department of Metabolism, Digestion and Reproduction, Imperial College, Burlington Danes Building, Du Cane Road, London W12 0NN, UK.
| | - Colin F Poole
- Department of Chemistry, Wayne State University, Detroit, MI 48202, USA.
| |
Collapse
|
6
|
Chen M, Sun L, Ma Q, Yang J, Kang Q, Yang Y, Rong R. An affinity interaction guided two-dimensional separation system for the screening of neuraminidase inhibitors from Reynoutria japonica Houtt. roots. J Chromatogr A 2022; 1678:463338. [PMID: 35901666 DOI: 10.1016/j.chroma.2022.463338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Revised: 06/25/2022] [Accepted: 07/11/2022] [Indexed: 10/17/2022]
Abstract
Discovering bioactive compounds from medicinal herbs is crucial for drug discovery. Ultrafiltration is often used in the screening of bioactive compounds from natural herbs because of its simple and rapid operations. However, the ultrafiltration results are often disturbed by the undissolved compounds and the non-target compounds, which reduces the accuracy of the results. Herein, an affinity interaction guided two-dimensional (2D) separation system was developed. Discovery of the potential neuraminidase (NA) inhibitors from the dried roots of Reynoutria japonica Houtt. (RRJ) was used as an example. Only the small molecules showing affinity interaction with NA could be screened by the affinity interaction guided 2D separation system. Firstly, the NA and crude extract were incubated to form a sample solution (containing NA-inhibitor complexes, NA, and three types of small molecules with different polarities) by affinity interaction. Then the sample solution was separated and detected by the 2D separation system. This aimed to reduce the interference of the undissolved compounds and non-target compounds, and pick out the NA-inhibitor complexes (NA-Is). The collected NA-Is were denatured to release small molecular inhibitors (Is) for LC-MS/MS analysis. Compared with the ultrafiltration, more obvious peak area differences were observed in the results, and four potential NA inhibitors were successfully identified. In all, we provided a simple strategy with better performance in the screening of natural bioactive compounds.
Collapse
Affiliation(s)
- Menghan Chen
- College of Pharmacy, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China
| | - Linlin Sun
- Experimental Center, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China
| | - Qingyun Ma
- College of Pharmacy, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China
| | - Jia Yang
- College of Pharmacy, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China
| | - Qianli Kang
- College of Pharmacy, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China
| | - Yong Yang
- Experimental Center, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China; Collaborative Innovation Center for Antiviral Traditional Chinese Medicine in Shandong Province, Jinan, 250355, PR China.
| | - Rong Rong
- College of Pharmacy, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China; Collaborative Innovation Center for Antiviral Traditional Chinese Medicine in Shandong Province, Jinan, 250355, PR China.
| |
Collapse
|
7
|
Baetz N, Schmidt TC, Tuerk J. High-performance thin-layer chromatography in combination with an acetylcholinesterase-inhibition bioassay with pre-oxidation of organothiophosphates to determine neurotoxic effects in storm, waste, and surface water. Anal Bioanal Chem 2022; 414:4167-4178. [PMID: 35583680 PMCID: PMC9124651 DOI: 10.1007/s00216-022-04068-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 02/26/2022] [Accepted: 04/05/2022] [Indexed: 11/17/2022]
Abstract
Pesticides such as organothiophosphates (OTPs) are neurotoxically active and enter the aquatic environment. Bioassays, using acetylcholinesterase (AChE), a suitable substrate and reactant, can be applied for the photometric detection of AChE-inhibiton (AChE-I) effects. The oxidized forms of OTPs, so-called oxons, have higher inhibition potentials for AChE. Therefore, a higher sensitivity is achieved for application of oxidized samples to the AChE assay. In this study, the oxidation of malathion, parathion, and chlorpyrifos by n-bromosuccinimide (NBS) was investigated in an approach combining high-performance thin-layer chromatography (HPTLC) with an AChE-I assay. Two AChE application approaches, immersion and spraying, were compared regarding sensitivity, precision, and general feasibility of the OTP effect detection. The oxidation by NBS led to an activation of the OTPs and a strong increase in sensitivity similar to the oxons tested. The sensitivity and precision of the two application techniques were similar, although the spray method was slightly more sensitive to the oxidized OTPs. The 10% inhibition concentrations (IC10) for the spray approach were 0.26, 0.75, and 0.35 ng/spot for activated malathion, parathion, and chlorpyrifos, respectively. AChE-I effect recoveries in samples from a stormwater retention basin and receiving stream were between 69 and 92% for malathion, parathion, and chlorpyrifos. The overall workflow, including sample enrichment by solid-phase extraction, HPTLC, oxidation of OTPs, and AChE-I assay, was demonstrated to be suitable for the detection of AChE-I effects in native water samples. An effect of unknown origin was found in a sample from a stormwater retention basin.
Collapse
Affiliation(s)
- Nicolai Baetz
- Institut für Energie- und Umwelttechnik e. V. (IUTA, Institute of Energy and Environmental Technology), Bliersheimer Str. 58-60, 47229, Duisburg, Germany
- Instrumental Analytical Chemistry, Faculty of Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141, Essen, Germany
- Center for Water and Environmental Research (ZWU), University of Duisburg-Essen, Universitätsstr. 2, 45141, Essen, Germany
| | - Torsten C Schmidt
- Instrumental Analytical Chemistry, Faculty of Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141, Essen, Germany
- Center for Water and Environmental Research (ZWU), University of Duisburg-Essen, Universitätsstr. 2, 45141, Essen, Germany
| | - Jochen Tuerk
- Institut für Energie- und Umwelttechnik e. V. (IUTA, Institute of Energy and Environmental Technology), Bliersheimer Str. 58-60, 47229, Duisburg, Germany.
- Center for Water and Environmental Research (ZWU), University of Duisburg-Essen, Universitätsstr. 2, 45141, Essen, Germany.
| |
Collapse
|
8
|
Recent Advances in Sampling and Sample Preparation for Effect-Directed Environmental Analysis. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116654] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
9
|
Performance of free-flow field-step electrophoresis as cleanup step for the non-target analysis of environmental water samples. Anal Bioanal Chem 2022; 414:2189-2204. [PMID: 35099581 PMCID: PMC8821473 DOI: 10.1007/s00216-021-03856-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 12/14/2021] [Accepted: 12/17/2021] [Indexed: 11/22/2022]
Abstract
For the analysis of low concentrations of micropollutants in environmental water samples, efficient sample enrichment and cleanup are necessary to reduce matrix effects and to reach low detection limits. For analytes of low and medium polarity, solid-phase extraction is used, but robust methods for the preconcentration of highly polar or ionizable analytes are scarce. In this work, field-step electrophoresis (FSE) was developed as an environmental sample cleanup technique for ionizable micropollutants and ionic transformation products. The FSE electrolyte system preconcentrated 15 acidic model analytes (pKa from −2.2 to 9.1) present in aqueous samples in two fractions by factors of 5–10. Simultaneously, highly mobile matrix compounds were removed including inorganic ions such as sulfate and chloride. The fractions were either directly injected for downstream analysis by reversed-phase liquid chromatography (RPLC) or further processed by evaporative preconcentration with subsequent reconstitution in an organic solvent suitable for separation methods like hydrophilic interaction chromatography. The FSE/RPLC-MS method exhibited high quantitative precision with RSDs of 3–6%. The method was successfully applied to a spiked river water sample and its performance compared with common solid-phase extraction and evaporative concentration, demonstrating a high analyte coverage. FSE combined with non-target screening by RPLC-MS revealed a strong reduction in matrix load especially at low retention times. Seventeen compounds were identified in the FSE fractions sampled at the field step boundary by retention time, accurate mass, and mass fragments. Suspect screening by FSE/RPLC-MS was facilitated by FSE’s selectivity for anionic compounds.
Collapse
|
10
|
Chen Y, Chen Q, Wei X. Separable surface enhanced Raman spectroscopy sensor platformed by HPTLC for facile screening of malachite green in fish. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106694] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
11
|
Jochums M, Kochale K, Teutenberg T, Türk J, Bergstedt U. Vorteile von Open‐Source‐Ansätzen bei der Etablierung einer automatisierten wirkungsbezogenen Analytik. CHEM-ING-TECH 2021. [DOI: 10.1002/cite.202100103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Max Jochums
- Institut für Energie- und Umwelttechnik e.V. (IUTA) Abteilung Forschungsanalytik & Miniaturisierung Bliersheimer Straße 58–60 47229 Duisburg Deutschland
| | - Kjell Kochale
- Institut für Energie- und Umwelttechnik e.V. (IUTA) Abteilung Forschungsanalytik & Miniaturisierung Bliersheimer Straße 58–60 47229 Duisburg Deutschland
| | - Thorsten Teutenberg
- Institut für Energie- und Umwelttechnik e.V. (IUTA) Abteilung Forschungsanalytik & Miniaturisierung Bliersheimer Straße 58–60 47229 Duisburg Deutschland
| | - Jochen Türk
- Institut für Energie- und Umwelttechnik e.V. (IUTA) Abteilung Umwelthygiene & Spurenstoffe Bliersheimer Straße 58–60 47229 Duisburg Deutschland
| | - Uta Bergstedt
- Hochschule Niederrhein Fachbereich Chemie Abteilung Biotechnologie Adlerstraße 32 47798 Krefeld Deutschland
| |
Collapse
|
12
|
Baetz N, Rothe L, Wirzberger V, Sures B, Schmidt TC, Tuerk J. High-performance thin-layer chromatography in combination with a yeast-based multi-effect bioassay to determine endocrine effects in environmental samples. Anal Bioanal Chem 2021; 413:1321-1335. [PMID: 33388849 DOI: 10.1007/s00216-020-03095-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 10/16/2020] [Accepted: 11/25/2020] [Indexed: 12/26/2022]
Abstract
Effect-directed analysis (EDA) that combines effect-based methods (EBMs) with high-performance thin-layer chromatography (HPTLC) is a useful technique for spatial, temporal, and process-related effect evaluation and may provide a link between effect testing and responsible substance identification. In this study, a yeast multi endocrine-effect screen (YMEES) for the detection of endocrine effects is combined with HPTLC. Simultaneous detection of estrogenic, androgenic, and gestagenic effects on the HPTLC plate is achieved by mixing different genetically modified Arxula adeninivorans yeast strains, which contain either the human estrogen, androgen, or progesterone receptor. Depending on the yeast strain, different fluorescent proteins are formed when an appropriate substance binds to the specific hormone receptor. This allows to measure hormonal effects at different wavelengths. Two yeast cell application approaches, immersion and spraying, are compared. The sensitivity and reproducibility of the method are shown by dose-response investigations for reference compounds. The spraying approach indicated similar sensitivities and higher precisions for the tested hormones compared to immersion. The EC10s for estrone (E1), 17β-estradiol (E2), 17α-ethinylestradiol (EE2), 5α-dihydrotestosterone (DHT), and progesterone (P4) were 95, 1.4, 10, 7.4, and 15 pg/spot, respectively. Recovery rates of E1, E2, EE2, DHT, and P4 between 88 and 120% show the usability of the general method in combination with sample enrichment by solid phase extraction (SPE). The simultaneous detection of estrogenic, androgenic, and gestagenic effects in wastewater and surface water samples demonstrates the successful application of the YMEES in such matrices. This promising method allows us to identify more than one endocrine effect on the same HPTLC plate, which saves time and material. The method could be used for comparison, evaluation, and monitoring of different river sites and wastewater treatment steps and should be tested in further studies.
Collapse
Affiliation(s)
- Nicolai Baetz
- Institut für Energie- und Umwelttechnik e. V. (IUTA, Institute of Energy and Environmental Technology), Bliersheimer Str. 58 - 60, 47229, Duisburg, Germany.,Instrumental Analytical Chemistry, Faculty of Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141, Essen, Germany.,Centre for Water and Environmental Research (ZWU), University Duisburg-Essen, Universitätsstr. 2, 45141, Essen, Germany
| | - Louisa Rothe
- Centre for Water and Environmental Research (ZWU), University Duisburg-Essen, Universitätsstr. 2, 45141, Essen, Germany.,Aquatic Ecology, Faculty of Biology, University of Duisburg-Essen, Universitätsstr. 5, 45141, Essen, Germany
| | - Vanessa Wirzberger
- Instrumental Analytical Chemistry, Faculty of Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141, Essen, Germany.,Centre for Water and Environmental Research (ZWU), University Duisburg-Essen, Universitätsstr. 2, 45141, Essen, Germany
| | - Bernd Sures
- Centre for Water and Environmental Research (ZWU), University Duisburg-Essen, Universitätsstr. 2, 45141, Essen, Germany.,Aquatic Ecology, Faculty of Biology, University of Duisburg-Essen, Universitätsstr. 5, 45141, Essen, Germany
| | - Torsten C Schmidt
- Instrumental Analytical Chemistry, Faculty of Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141, Essen, Germany.,Centre for Water and Environmental Research (ZWU), University Duisburg-Essen, Universitätsstr. 2, 45141, Essen, Germany
| | - Jochen Tuerk
- Institut für Energie- und Umwelttechnik e. V. (IUTA, Institute of Energy and Environmental Technology), Bliersheimer Str. 58 - 60, 47229, Duisburg, Germany. .,Centre for Water and Environmental Research (ZWU), University Duisburg-Essen, Universitätsstr. 2, 45141, Essen, Germany.
| |
Collapse
|