1
|
Sánchez-García A, Molina-Martin A, Ariza-Gracia MÁ, Piñero DP. Analysis of Treatment Discontinuation in Orthokeratology: Studying Efficacy, Safety, and Patient Adherence Over Six Months. Eye Contact Lens 2024; 50:395-400. [PMID: 38886923 DOI: 10.1097/icl.0000000000001110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/20/2024]
Abstract
PURPOSE This study aimed to evaluate the efficacy, safety, and participant compliance of orthokeratology treatment for the correction of myopic refractive errors over a six-month prospective study and to define the potential reasons for early treatment discontinuation. METHODS A total of 32 participants with low-to-moderate myopia were fitted with the spherical model of corneal refractive therapy (CRT) orthokeratology lenses (Paragon Vision Sciences) and followed over six months, with specific attention to alterations in refractive error, corneal topography, and epithelial thickness. Concurrently, participant feedback and reasons for any treatment discontinuation were documented. RESULTS Significant changes in refractive error and in corneal topography were observed, with approximately 50% of the refractive error being corrected on the first night of use and 100% by the first two weeks ( P <0.001). Central epithelial thickness experienced substantial thinning, reducing to 15.65±4.49 μm (67.38%) ( P <0.001) after 6 months of lens use. Six participants withdrew from this study for varied reasons, including unmet visual expectations and difficulty adhering to the lens-wearing regimen. Notably, the dropout group exhibited higher baseline low-order aberrations and less prolate corneas than those who persisted with the treatment ( P <0.05). CONCLUSIONS Orthokeratology with CRT is efficacious and safe for the correction of low-to-moderate myopia in adults, but a portion of patients discontinue the treatment in the first 6 months of contact lens wear. Special care should be taken when recommending orthokeratology in patients with higher levels of myopia and corneas with less prolate shape, providing more realistic expectations and even changing to dual axis or more sophisticated designs.
Collapse
Affiliation(s)
- Alicia Sánchez-García
- Department of Optics (A.S.-G., A.M.-M., D.P.P.), Pharmacology and Anatomy, University of Alicante, Alicante, Spain; ARTORG Center for Biomedical Engineering Research (M.Á.A.-G), University of Bern, Bern, Switzerland; and Department of Ophthalmology (IMQO-Oftalmar) (D.P.P.), Vithas Medimar International Hospital, Alicante, Spain
| | | | | | | |
Collapse
|
2
|
Xiao J, Pan X, Hou C, Wang Q. Changes in Subfoveal Choroidal Thickness after Orthokeratology in Myopic Children: A Systematic Review and Meta-Analysis. Curr Eye Res 2024; 49:683-690. [PMID: 38305231 DOI: 10.1080/02713683.2024.2310618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 01/22/2024] [Indexed: 02/03/2024]
Abstract
AIMS This study aimed to synthesize the variations in subfoveal choroidal thickness (SFCT) observed at different follow-up intervals in myopic children undergoing orthokeratology treatment. MATERIALS AND METHODS Relevant articles were systematically retrieved from databases such as PubMed, EMBASE, Web of Science, and Cochrane Library. The retrieval period extended from the inception of these databases to November 2023. Means and standard deviations (SD) of baseline and post-treatment SFCT were selected as the results for analysis and calculation. RESULTS A total of eight articles involving 478 eyes fulfilled the inclusion criteria. At 1 month, 3 months, and 6 months intervals, the SFCT demonstrated significant increases by 16.74 μm (95% CI: 8.66, 24.82; p < 0.0001), 13.41 μm (95% CI: 4.36, 22.45; p = 0.004), and 17.57 μm (95% CI: 8.41, 26.73; p = 0.0002), respectively. Besides, children treated with orthokeratology exhibited a notably thicker change of SFCT in comparison with children with single-vision spectacles (SVL) (WMD = 13.50, 95% CI: 11.69, 15.13; p < 0.0001). CONCLUSION Myopic children undergoing orthokeratology treatment experience a discernible increase in SFCT at 1 month, 3 months, and 6 months. Furthermore, compared to children utilizing SVL, those undergoing orthokeratology manifest a more pronounced thickening of SFCT.
Collapse
Affiliation(s)
- Jie Xiao
- Department of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Xinghui Pan
- Department of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Chenting Hou
- Department of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Qing Wang
- Department of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China
| |
Collapse
|
3
|
Martínez-Plaza E, López-de la Rosa A, Molina-Martín A, Piñero DP. Orthokeratology effect on the corneoscleral profile: Beyond the bull's eye. Ophthalmic Physiol Opt 2024; 44:757-768. [PMID: 38240175 DOI: 10.1111/opo.13279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 01/08/2024] [Accepted: 01/09/2024] [Indexed: 05/01/2024]
Abstract
PURPOSE To assess the impact of 3 months of orthokeratology (ortho-k) contact lenses (CLs) for myopia correction on the corneoscleral profile, as changes in scleral geometry could serve as indirect evidence of alteration in the corneal biomechanical properties. METHODS Twenty subjects (40 eyes) were recruited to wear ortho-k lenses overnight; however, after discontinuation (two CL fractures, one under-correction and two non-serious adverse events), 16 subjects (31 eyes) finished a 3-month follow-up. Corneoscleral topographies were acquired using the Eye Surface Profiler (ESP) system before and after 3 months of lens wear. Steep (SimKs) and flat (SimKf) simulated keratometry and scleral sagittal height measurements for 13-, 14- and 15-mm chord lengths were automatically calculated by the ESP software. Additionally, sagittal height and slope were calculated in polar format from 21 radii (0-10 mm from the corneal apex) at 12 angles (0-330°). Linear mixed models were fitted to determine the differences between visits. RESULTS SimKs and SimKf were increased significantly (p ≤ 0.02). The sagittal height in polar format increased significantly (p = 0.046) at a radius of 2.5 mm for 150°, 180°, 210° and 240° orientations and at a radius of 3.0 mm for 210°. Additionally, the slope in polar format significantly decreased (p ≤ 0.04) at radii ranges of 0.0-0.5, 0.5-1.0 and 1.0-1.5 mm for multiple angles and at a radii range of 5.0-5.5 mm for 90°. It also increased significantly (p ≤ 0.045) at a radii range of 1.5-2.0 mm for 30° and at radii ranges of 2.0-2.5, 2.5-3.0 and 3.0-3.5 mm for multiple angles. No significant changes were found for any parameter measured from the scleral area. CONCLUSIONS Three months of overnight ortho-k lens wear changed the central and mid-peripheral corneal geometry as expected, maintaining the peripheral cornea and the surrounding sclera stability.
Collapse
Affiliation(s)
- Elena Martínez-Plaza
- Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
- University of Valladolid, Valladolid, Spain
| | - Alberto López-de la Rosa
- Department of Theoretical Physics, Atomic and Optics, University of Valladolid, Valladolid, Spain
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain
| | - Ainhoa Molina-Martín
- Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| | - David P Piñero
- Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
- Department of Ophthalmology, Vithas Medimar International Hospital, Alicante, Spain
| |
Collapse
|
4
|
Pattan HF, Liu X, Tankam P. In vivo assessment of human corneal epithelial cells in orthokeratology lens wearers: A pilot study. Optom Vis Sci 2024; 101:263-271. [PMID: 38683973 DOI: 10.1097/opx.0000000000002130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2024] Open
Abstract
SIGNIFICANCE Central corneal epithelial thinning associated with midperipheral epithelial thickening has been reported as the main factor contributing to the effectiveness of orthokeratology (ortho-k) in myopia control. Yet, the cellular mechanism governing the regional change in refractive power remains elusive. PURPOSE This study aimed to evaluate the correlation between the regional change in corneal epithelial thickness and cell density in ortho-k wearers. METHODS A new human prototype of a polarization-dependent optical coherence microscope was developed to enable noncontact and noninvasive in vivo imaging of corneal epithelial cells in ortho-k wearers with and without their ortho-k lens. The epithelial thickness and cell density were evaluated at the central and midperipheral corneal locations in four ortho-k wearers and four spectacle wearers serving as controls. RESULTS Polarization-dependent optical coherence microscope achieved in vivo volumetric imaging of all epithelial cell types in ortho-k wearers with and without their lens over a field of view of 0.5 × 0.5 mm 2 with an isotropic resolution of ~2.2 mm. The central epithelial thinning and midperipheral epithelial thickening were consistent across all ortho-k wearers. However, the inconsistency in their regional epithelial cell density highlighted a great variability in individual response to ortho-k treatment. There was no strong correlation between epithelial thickness and cell density, especially at the midperipheral cornea, in ortho-k participants. CONCLUSIONS This study constitutes our first step toward uncovering the cellular mechanism underlying the effectiveness of ortho-k in myopia control. Future studies will focus on the longitudinal evaluation of epithelial cells before and during ortho-k treatment to identify factors governing individual response to ortho-k treatment and ultimately inform the dynamics of epithelial cells taking place during the ortho-k treatment.
Collapse
Affiliation(s)
- Hadiya F Pattan
- School of Optometry, Indiana University, Bloomington, Indiana
| | - Xiao Liu
- School of Optometry, Indiana University, Bloomington, Indiana
| | | |
Collapse
|
5
|
Xiang K, Chen J, Zhao W, Zhu Z, Ding L, Bulloch G, Du L, Xu X, Zhu M, He X. Changes of corneal biomechanics in children using orthokeratology and their roles in predicting axial length progression-A prospective 2-year study. Acta Ophthalmol 2023; 101:755-765. [PMID: 36959685 DOI: 10.1111/aos.15662] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 02/19/2023] [Accepted: 03/08/2023] [Indexed: 03/25/2023]
Abstract
PURPOSE To determine how orthokeratology (ortho-k) affects corneal biomechanical properties in myopia control and whether corneal biomechanical parameters can predict clinical efficacy of ortho-k. METHODS A total of 125 children 7-15 years of age using ortho-k lenses were followed in this clinical practice and data of their right eyes were analysed. Corneal biomechanical parameters and most ocular biometry were measured at baseline, 1 week, and at 1, 3, 6, 12, 18 and 24 months. Axial length (AL) was collected every 6 months after baseline measurements. RESULTS During the 2-year follow up, nine corneal biomechanical parameters, including deformation amplitude maximum (DA), varied between baseline and 1 week (p < 0.05) and stabilized during the rest of wearing period (p > 0.05). The mean AL increased from 25.02 ± 0.84 mm to 25.38 ± 0.81 mm and baseline DA strongly correlated with AL progression (Pearson r = 0.37). In the multiple regression models, baseline age, AL and DA were the independent factors for AL progression (R2 : 0.7849, 0.2180 in low and moderate myopes). The area under the receiver operating characteristic curves using the three variables for predicting excessive AL progression (>0.35 mm during 2 years) in low and moderate myopes was 0.902 and 0.698. CONCLUSIONS Corneal biomechanics firstly fluctuated before becoming stable with long-term ortho-k use. Corneal biomechanics was associated with AL progression in children wearing ortho-k lenses. DA combined with age and AL at baseline could predict AL progression in low myopes using ortho-k.
Collapse
Affiliation(s)
- Kaidi Xiang
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
- Department of Ophthalmology, Shanghai General Hospital, National Clinical Research Center for Eye Diseases, Center of Eye Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai Jiao Tong University, Shanghai, China
| | - Jun Chen
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
| | - Wenchen Zhao
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
- Department of Ophthalmology, Shanghai General Hospital, National Clinical Research Center for Eye Diseases, Center of Eye Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai Jiao Tong University, Shanghai, China
| | - Zhuoting Zhu
- Ophthalmology, Centre for Eye Research Australia, University of Melbourne, Melbourne, Australia
| | - Li Ding
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
| | - Gabriella Bulloch
- Ophthalmology, Centre for Eye Research Australia, University of Melbourne, Melbourne, Australia
| | - Linlin Du
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
| | - Xun Xu
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
- Department of Ophthalmology, Shanghai General Hospital, National Clinical Research Center for Eye Diseases, Center of Eye Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai Jiao Tong University, Shanghai, China
| | - Mengjun Zhu
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
| | - Xiangui He
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
- Department of Ophthalmology, Shanghai General Hospital, National Clinical Research Center for Eye Diseases, Center of Eye Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
6
|
Modeling and Prediction of the Immediate and Short-Term Effect of Myopic Orthokeratology. Eye Contact Lens 2023; 49:77-82. [PMID: 36694311 DOI: 10.1097/icl.0000000000000962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/22/2022] [Indexed: 01/26/2023]
Abstract
PURPOSE To characterize the clinical changes occurring in the initial phase of the orthokeratology (OK) treatment for myopia correction, developing a model of prediction of the refractive changes in such phase. METHODS Prospective study enrolling 64 eyes of 32 patients (range, 20-40 years) undergoing myopic OK treatment with the reverse geometry contact lens CRT (Paragon Vision Science). Changes in uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), refraction, corneal topography, ocular aberrations, and corneal epithelial thickness were evaluated during the first hour of OK lens wear and after 1 week of OK treatment. Multiple linear regression analysis was used to obtain a model to predict the short-term refractive effect of OK. RESULTS The UCVA improved at each visit, reaching normal visual acuity values after a week (P<0.001) of OK treatment, which was consistent with the significant spherical equivalent (SE) reduction and central flattening (P<0.001). Multiple linear regression analysis revealed that one night change in refraction (ΔR×1N) could be predicted according to the following expression (P<0.001, R2=0.686): ΔR×1N=1.042+0.028×Age+1.014×BCET (baseline central epithelium thickness)-0.752×BKm (baseline mean keratometry)-1.405×BSE (baseline SE)+1.032×ΔR×1 h (change in SE after 1 hr of OK lens use). Similarly, a statistically relevant linear relationship was obtained for predicting the refractive change after 1 week (ΔR×1W) of OK use (P<0.001, R2=0.928): ΔR×1W=3.470-1.046×BSE-1.552×BBCVA (baseline BCVA)-0.391×BKm+0.450×ΔR×1 h. CONCLUSIONS The immediate and short-term refractive effects of myopic OK with the reverse geometry contact lens CRT can be predicted with enough accuracy from baseline and first trial visits data.
Collapse
|
7
|
Xie C, Wei R. Long-term changes in the ocular surface during orthokeratology lens wear and their correlations with ocular discomfort symptoms. Cont Lens Anterior Eye 2023; 46:101757. [PMID: 36137919 DOI: 10.1016/j.clae.2022.101757] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 09/01/2022] [Accepted: 09/08/2022] [Indexed: 01/18/2023]
Abstract
PURPOSE To evaluate the changes in ocular surface parameters during orthokeratology lens wear and determine their correlations with ocular discomfort symptoms. METHODS Fifty individuals were enrolled in this prospective pilot study. Clinical evaluation of the ocular surface included the ocular surface disease index, slit-lamp examination, Keratograph 5M, optical quality analysis system, and corneal staining. After baseline examinations, clinical tests were performed at 1 day, 1 week, 1 month, 3 months, 6 months, and 12 months after orthokeratology lens wear. Correlations between ocular discomfort symptoms and signs of ocular discomfort were evaluated. RESULTS Overall ocular surface disease index score and two subscale scores (ocular symptoms and vision-related function) significantly increased at the 3-month visit (P < 0.05), and decreased to levels close to baseline at the12-month visit (P > 0.05). The basic objective scatter index and the mean tear film objective scatter index increased, peaking at 3-month visit (P < 0.05) and gradually decreased thereafter. The modulation transfer function cut-off significantly decreased at the 3-month visit (P < 0.05). During the 12-month study period, the overall ocular surface disease index score and vision-related function score were significantly and positively correlated with the basic objective scatter index and mean tear film objective scatter index (P < 0.05). After 1 week of lens wear, Grade 1 corneal staining increased to 16.4 %, mostly involving the central and inferior cornea. CONCLUSIONS Orthokeratology lens wear increased ocular discomfort symptoms and decreased the function of tear film, mainly within 3 months of lens wear. Tear-related visual function parameters were correlated with ocular discomfort. A new parameter, tear film objective scatter index, measured with the optical quality analysis system, was more sensitive in detecting the quality and stability of tear film than traditional indicators.
Collapse
Affiliation(s)
- Caiyuan Xie
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Fukang Road. 251, Nankai District, Tianjin 300384, China
| | - Ruihua Wei
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Fukang Road. 251, Nankai District, Tianjin 300384, China.
| |
Collapse
|
8
|
Ren X, Chou Y, Wang Y, Jing D, Chen Y, Li X. The Utility of Oral Vitamin B1 and Mecobalamin to Improve Corneal Nerves in Dry Eye Disease: An In Vivo Confocal Microscopy Study. Nutrients 2022; 14:nu14183750. [PMID: 36145126 PMCID: PMC9504679 DOI: 10.3390/nu14183750] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Revised: 09/03/2022] [Accepted: 09/08/2022] [Indexed: 11/24/2022] Open
Abstract
Our purpose is to demonstrate the changes in cornea nerve parameters and symptoms and signs in dry eye disease (DED) patients after oral vitamin B1 and mecobalamin treatment. In this randomized double-blind controlled trial, DED patients were randomly assigned to either the treatment group (oral vitamin B1 and mecobalamin, artificial tears) or the control group (artificial tears). Corneal nerve parameters via in vivo confocal microscopy (IVCM), DED symptoms, and signs were assessed at baseline and 1 and 3 months post-treatment. In total, 398 eyes from 199 patients were included. In the treatment group, there were significant improvements in corneal nerve length, width, and neuromas, the sign of conjunctival congestion score (CCS), symptoms of dryness, pain, photophobia, blurred vision, total symptom score, and OSDI (OSDI) at 1/3 months post-treatment (all p < 0.05). Patients who received vitamin B1 and mecobalamin showed greater improvement in CCS, dryness scores at 1 month (p < 0.05), corneal fluorescein staining (CFS) (p = 0.012), photophobia (p = 0.032), total symptom scores (p = 0.041), and OSDI (p = 0.029) at 3 months. Greater continuous improvement in CFS (p = 0.045), dryness (p = 0.033), blurred vision (p = 0.031) and total symptom scores (p = 0.023) was demonstrated at 3 months than at 1 month post-treatment in the treatment group. We found that oral vitamin B1 and mecobalamin can improve corneal nerve length, width, reflectivity and the number of neuromas in IVCM, thereby repairing epithelial cells and alleviating some ocular symptoms. Thus, vitamin B1 and mecobalamin are potential treatment options for patients with DED.
Collapse
Affiliation(s)
- Xiaotong Ren
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
| | - Yilin Chou
- Department of Ophthalmology, BenQ Medical Center, The Affiliated BenQ Hospital of Nanjing Medical University, Nanjing 210000, China
| | - Yuexin Wang
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
| | - Dalan Jing
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
| | - Yanyan Chen
- Department of Ophthalmology, Daqing Oilfield General Hospital, Daqing 163311, China
| | - Xuemin Li
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
- Correspondence: ; Tel.: +86-15611908409
| |
Collapse
|
9
|
Lipson MJ. The Role of Orthokeratology in Myopia Management. Eye Contact Lens 2022; 48:189-193. [PMID: 35333801 DOI: 10.1097/icl.0000000000000890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/16/2021] [Indexed: 11/04/2022]
Abstract
ABSTRACT Intervention to slow axial elongation and progressing degree of myopia has become an important public health issue. Although orthokeratology (OrthoK) has been prescribed to temporarily reduce or eliminate refractive error, myopic children undergoing OrthoK have shown significant slowing of axial elongation and myopic progression. This review presents data on the efficacy, benefits, and risks of the use of OrthoK to slow axial elongation in myopic children. It also discusses how OrthoK fits into an overall strategy of myopia management in practice compared with alternative prescribed interventions to slow myopic progression. Other factors discussed are patient candidacy, impact on vision-related quality of life, and use of OrthoK in combination with pharmaceutical agents. With precise fitting, careful follow-up, and patient compliance with recommended lens cleaning and disinfection, OrthoK is a safe and effective method to slow axial elongation in children.
Collapse
Affiliation(s)
- Michael J Lipson
- Kellogg Eye Center, Department of Ophthalmology and Visual Science, University of Michigan, Commerce Twp, MI
| |
Collapse
|
10
|
Ring-Mangold T, Emminger R. [Orthokeratology - a Perfect Vision Overnight - An Update and Overview]. Klin Monbl Augenheilkd 2021; 238:913-931. [PMID: 33873209 DOI: 10.1055/a-1472-0517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Orthokeratology offers the unique possibility of correcting myopia: a special reverse geometry contact lens used exclusively during sleeping hours at nighttime. The authors give a comprehensive overview about the evolving technique, including the careful selection of patients, and practical contact lens fitting. They explain a series of daily life situations and point out dos and don'ts. Limitations of orthokeratology are highlighted with regard to refraction errors and anatomical conditions. Early regression and glare due to corneal aberrations are common negative side effects. Critical complications like bacterial keratitis, ocular surface disorders, and morphologic changes through corneal molding as corneal hypoesthesia and ferritin deposits are considered. Emerging applications are discussed: correction of presbyopia, corneal crosslinking to stabilize the ortho-k effect, myopia control in children, topographically controlled and individualized contact lens geometries using advanced contact lens materials. Legal regulations concerning the driving permission are outlined. Nevertheless, orthokeratology seems to be a well-established niche technology predominantly useful in young, healthy, and active myopic patients. The fitting and care of this refractive tool is demanding and costly. However, these lenses fill the gap between every day conventional contact lens and surgical refractive methods. Another growing application of high interest is myopia control in children.
Collapse
|
11
|
Ring-Mangold T, Emminger R. Die moderne Orthokeratologie – scharf sehen über
Nacht. AUGENHEILKUNDE UP2DATE 2021. [DOI: 10.1055/a-1262-3205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
ZusammenfassungOhne Sehhilfe durchs Leben zu gehen – ein durchaus realistischer Traum. In der
Liga der refraktiven Korrekturoptionen spielt die Orthokeratologie ihre sehr
eigene Rolle. Das Prinzip: Eine hoch gaspermeable, formstabile Kontaktlinse, die
nachts während des Schlafs getragen wird, verändert durch ihre spezielle
Geometrie die Radien der Cornea reversibel in genau der Art und Weise, dass die
Refraktion des Auges tagsüber unkorrigiert der Emmetropie nahekommt.
Collapse
|