1
|
Amini M, Kazemnejad A, Rasekhi A, Amirian A, Kariman N. Early prediction of gestational diabetes mellitus using first trimester maternal serum pregnancy-associated plasma protein-a: A cross-sectional study. Health Sci Rep 2024; 7:e70090. [PMID: 39355100 PMCID: PMC11439745 DOI: 10.1002/hsr2.70090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 07/16/2024] [Accepted: 09/05/2024] [Indexed: 10/03/2024] Open
Abstract
Background and Aims The oral glucose tolerance test with 75 g glucose is commonly regarded as the gold standard (GS) for the detection of gestational diabetes mellitus (GDM). However, one limitation of this test is its administration in the late second trimester of pregnancy in some countries (e.g., Iran). This study aimed to evaluate the accuracy of pregnancy-associated plasma protein-A (PAPP-A) for predicting GDM in the early first trimester of pregnancy using a novel statistical modeling technique. Methods The study population consisted of 344 pregnant women who participated in the first trimester screening program for GDM. Maternal serum PAPP-A levels were measured between 11 and 13 gestational weeks for all participants. A Bayesian latent profile model (LPM) under the skew-t (ST) distribution was employed to estimate the diagnostic accuracy measures of PAPP-A in the absence of GS test outcomes. Results The mean (standard deviation) age of the participants was 28.87 ± 5.20 years. The median (interquartile range (IQR)) PAPP-A MoM was 0.91 (0.69-1.34). Utilizing the LPM under the ST distribution while adjusting for covariates, the sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of PAPP-A were 92% (95% credible interval [CrI]: 0.89, 0.98), 81% (95% CrI: 0.76, 0.91), and 0.91 (95% CrI: 0.83, 0.97), respectively. Notably, the pregnant women with GDM had significantly lower PAPP-A values (β = -0.52, 95% CrI [-0.61, -0.46]). Conclusion Generally, our findings confirmed that PAPP-A could serve as a potential screening tool for the identification of GDM in the early stages of pregnancy.
Collapse
Affiliation(s)
- Maedeh Amini
- Department of Biostatistics, Faculty of Medical SciencesTarbiat Modares UniversityTehranIran
| | - Anoshirvan Kazemnejad
- Department of Biostatistics, Faculty of Medical SciencesTarbiat Modares UniversityTehranIran
| | - Aliakbar Rasekhi
- Department of Biostatistics, Faculty of Medical SciencesTarbiat Modares UniversityTehranIran
| | - Azam Amirian
- Department of Midwifery, School of Nursing and MidwiferyJiroft University of Medical SciencesJiroftIran
| | - Nourossadat Kariman
- Department of Midwifery and Reproductive Health, School of Nursing and MidwiferyShahid Beheshti University of Medical SciencesTehranIran
| |
Collapse
|
2
|
Beck HC, Jensen LO, Gils C, Ilondo AMM, Frydland M, Hassager C, Møller-Helgestad OK, Møller JE, Rasmussen LM. Proteomic Discovery and Validation of the Confounding Effect of Heparin Administration on the Analysis of Candidate Cardiovascular Biomarkers. Clin Chem 2018; 64:1474-1484. [DOI: 10.1373/clinchem.2017.282665] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2017] [Accepted: 07/05/2018] [Indexed: 12/13/2022]
Abstract
Abstract
BACKGROUND
Several plasma proteins have been suggested as markers for a variety of cardiovascular conditions but fail to qualify in independent patient cohorts. This may relate to interference of medication on plasma protein concentrations. We used proteomics to identify plasma proteins that changed in concentration with heparin administration and therefore potentially may confound their evaluation as biomarkers in situations in which heparin is used.
METHODS
We used a proteomic approach based on isobaric tagging and nano-LC-MS/MS analysis to quantify several hundred proteins in a discovery study in which individual plasma samples from 9 patients at intravascular ultrasound follow-up 12 months after an acute myocardial infarction before heparin administration and 2, 15, and 60 min after heparin administration; we validated our findings in 500 individual plasma samples obtained at admission from patients with suspected ST segment elevation myocardial infarction (STEMI), of whom 363 were treated with heparin before admission.
RESULTS
In the discovery study, 25 of 653 identified plasma proteins displayed a changed concentration after heparin administration (Bonferroni-corrected P value at P < 7.66 × 10−5). Fourteen of the proteins changed significantly among heparin-treated patients in the validation study (nominal significance level of P < 6.92 × 10−5). Among heparin-affected proteins in both the discovery study and the validation study were midkine, spondin 1, secreted frizzled-like protein 1, lipoprotein lipase, and follistatin, all previously associated with STEMI.
CONCLUSIONS
Medications such as heparin administration given before blood sampling may confound biomarker discovery and should be carefully considered in such studies.
Collapse
Affiliation(s)
- Hans C Beck
- Department of Clinical Biochemistry and Pharmacology
- Centre for Clinical Proteomics
| | - Lisette O Jensen
- Department of Cardiology
- Center for Individualized Medicine in Arterial Diseases, Odense University Hospital, University of Southern Denmark, Denmark
| | | | | | - Martin Frydland
- Heart Center, Copenhagen University Hospital, Rigshospitalet, Denmark
| | | | - Ole K Møller-Helgestad
- Department of Cardiology
- Center for Individualized Medicine in Arterial Diseases, Odense University Hospital, University of Southern Denmark, Denmark
| | - Jacob E Møller
- Department of Cardiology
- Center for Individualized Medicine in Arterial Diseases, Odense University Hospital, University of Southern Denmark, Denmark
| | - Lars M Rasmussen
- Department of Clinical Biochemistry and Pharmacology
- Centre for Clinical Proteomics
- Center for Individualized Medicine in Arterial Diseases, Odense University Hospital, University of Southern Denmark, Denmark
| |
Collapse
|
3
|
Hjortebjerg R. IGFBP-4 and PAPP-A in normal physiology and disease. Growth Horm IGF Res 2018; 41:7-22. [PMID: 29864720 DOI: 10.1016/j.ghir.2018.05.002] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2018] [Revised: 05/15/2018] [Accepted: 05/29/2018] [Indexed: 02/07/2023]
Abstract
Insulin-like growth factor (IGF) binding protein-4 (IGFBP-4) is a modulator of the IGF system, exerting both inhibitory and stimulatory effects on IGF-induced cellular growth. IGFBP-4 is the principal substrate for the enzyme pregnancy-associated plasma protein-A (PAPP-A). Through IGF-dependent cleavage of IGFBP-4 in the vicinity of the IGF receptor, PAPP-A is able to increase IGF bioavailability and stimulate IGF-mediated growth. Recently, the stanniocalcins (STCs) were identified as novel inhibitors of PAPP-A proteolytic activity, hereby adding additional members to the seemingly endless list of proteins belonging to the IGF family. Our understanding of these proteins has advanced throughout recent years, and there is evidence to suggest that the role of IGFBP-4 and PAPP-A in defining the relationship between total IGF and IGF bioactivity can be linked to a number of pathological conditions. This review provides an overview of the experimental and clinical findings on the IGFBP-4/PAPP-A/STC axis as a regulator of IGF activity and examines the conundrum surrounding extrapolation of circulating concentrations to tissue action of these proteins. The primary focus will be on the biological significance of IGFBP-4 and PAPP-A in normal physiology and in pathophysiology with emphasis on metabolic disorders, cardiovascular diseases, and cancer. Finally, the review assesses current new trajectories of IGFBP-4 and PAPP-A research.
Collapse
Affiliation(s)
- Rikke Hjortebjerg
- Medical Research Laboratory, Department of Clinical Medicine, Faculty of Health, Aarhus University, Aarhus, Denmark; The Danish Diabetes Academy, Odense, Denmark.
| |
Collapse
|
4
|
Hjortebjerg R, Lindberg S, Pedersen S, Mogelvang R, Jensen JS, Oxvig C, Frystyk J, Bjerre M. Insulin-Like Growth Factor Binding Protein 4 Fragments Provide Incremental Prognostic Information on Cardiovascular Events in Patients With ST-Segment Elevation Myocardial Infarction. J Am Heart Assoc 2017; 6:e005358. [PMID: 28314798 PMCID: PMC5524039 DOI: 10.1161/jaha.116.005358] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Accepted: 02/07/2017] [Indexed: 01/06/2023]
Abstract
BACKGROUND Fragments of insulin-like growth factor binding protein 4 (IGFBP-4) are potential new biomarkers for cardiac risk assessment. The fragments are generated on specific cleavage by pregnancy-associated plasma protein-A, which exerts proatherogenic activity. This study investigated the prognostic value of IGFBP-4 fragments in patients with ST-segment elevation myocardial infarction. METHODS AND RESULTS We prospectively included 656 patients with ST-segment elevation myocardial infarction treated with percutaneous coronary intervention from September 2006 to December 2008. Blood samples were drawn before percutaneous coronary intervention, and levels of intact IGFBP-4 and N-terminal and C-terminal IGFBP-4 fragments were measured by specific assays. End points were 5-year all-cause and cardiovascular mortality and the combined end point of major adverse cardiac events. Prognostic potential was evaluated on top of a clinical model in terms of discrimination, calibration, and reclassification analysis. During follow-up, 166 patients experienced a major adverse cardiac event and 136 patients died, of whom 69 died from cardiovascular causes. Both IGFBP-4 fragments were associated with all end points (P<0.001). After multivariable adjustments, both N-terminal and C-terminal IGFBP-4 fragment levels remained associated with all end points, including cardiovascular mortality with hazard ratios per doubling in protein concentration of 2.54 (95% CI 1.59-4.07; P<0.001) and 2.07 (95% CI 1.41-3.04; P<0.001), respectively. Incorporation of IGFBP-4 fragments into a clinical model with 15 risk factors improved C-statistics and model calibration and provided incremental prognostic contribution, as assessed by net reclassification improvement and integrated discrimination improvement. CONCLUSIONS IGFBP-4 fragments are associated with increased risk of all-cause mortality, cardiovascular mortality, and major adverse cardiac events in patients with ST-segment elevation myocardial infarction.
Collapse
Affiliation(s)
- Rikke Hjortebjerg
- Medical Research Laboratory, Department of Clinical Medicine, Faculty of Health, Aarhus University, Aarhus, Denmark
- The Danish Diabetes Academy, Odense, Denmark
| | - Søren Lindberg
- Department of Cardiology P, Gentofte University Hospital, Copenhagen, Denmark
| | - Sune Pedersen
- Department of Cardiology P, Gentofte University Hospital, Copenhagen, Denmark
| | - Rasmus Mogelvang
- Department of Cardiology P, Gentofte University Hospital, Copenhagen, Denmark
| | - Jan S Jensen
- Department of Cardiology P, Gentofte University Hospital, Copenhagen, Denmark
- Institute of Clinical Medicine, Faculty of Health Sciences, University of Copenhagen, Denmark
| | - Claus Oxvig
- Department of Molecular Biology and Genetics, Faculty of Science and Technology, Aarhus University, Aarhus, Denmark
| | - Jan Frystyk
- Medical Research Laboratory, Department of Clinical Medicine, Faculty of Health, Aarhus University, Aarhus, Denmark
- Department of Endocrinology and Internal Medicine, Aarhus University Hospital, Aarhus, Denmark
| | - Mette Bjerre
- Medical Research Laboratory, Department of Clinical Medicine, Faculty of Health, Aarhus University, Aarhus, Denmark
| |
Collapse
|
5
|
Gutiérrez-Leonard H, Martínez-Lara E, Fierro-Macías AE, Mena-Burciaga VM, Ronquillo-Sánchez MD, Floriano-Sánchez E, Cárdenas-Rodríguez N. Pregnancy-associated plasma protein-A (PAPP-A) as a possible biomarker in patients with coronary artery disease. Ir J Med Sci 2016; 186:597-605. [PMID: 27730332 DOI: 10.1007/s11845-016-1515-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2016] [Accepted: 10/01/2016] [Indexed: 10/20/2022]
Abstract
BACKGROUND Cardiovascular disease is the leading cause of death in the Western world, and a major cause of this disease is atherosclerosis. Research has demonstrated that pregnancy-associated plasma protein A (PAPP-A) plays a role in cardiovascular disease, as evidenced by the association between PAPP-A and severity of heart damage. AIM The aim of this work was to investigate the correlation between PAPP-A concentrations in coronary and peripheral blood and certain clinicopathological factors and antioxidant enzyme activities in patients diagnosed with coronary artery disease. METHODS For 65 patients, arterial blood was obtained by puncturing the femoral or radial artery, and coronary blood was obtained via percutaneous coronary intervention. PAPP-A, catalase (CAT), superoxide dismutase-1 (SOD-1), and superoxide dismutase-2 (SOD-2) levels were measured using spectrometric methods. RESULTS Coronary PAPP-A levels were slightly higher than peripheral PAPP-A levels (81.25 ± 2.34 and 62 ± 3 ng/mL, respectively, P < 0.0001); these levels were correlated with each other (r = 0.6629, P < 0.001) but not with clinicopathological factors (P > 0.05). Coronary PAPP-A levels were significantly elevated among patients at risk for cardiovascular disease (P < 0.05). Antioxidant enzyme activities were significantly higher in coronary samples than in peripheral samples from subjects with ischemic cardiopathy secondary to atherosclerosis (P < 0.001). Neither coronary nor peripheral PAPP-A levels were correlated with antioxidant enzyme activities in patients with cardiopathy secondary to atherosclerosis (P > 0.05). CONCLUSIONS PAPP-A levels could be used as biomarkers to identify patients at risk of coronary artery disease.
Collapse
Affiliation(s)
- H Gutiérrez-Leonard
- Interventional Cardiology Laboratory, Hospital Central Militar, Secretaría de la Defensa Nacional, 11649, Mexico City, Mexico
| | - E Martínez-Lara
- Multidisciplinary Research Laboratory, Escuela Militar de Graduados de Sanidad, Secretaría de la Defensa Nacional, 11200, Mexico City, Mexico
| | - A E Fierro-Macías
- Section of Graduate Studies and Research, Escuela Superior de Medicina, Instituto Politécnico Nacional, 11340, Mexico City, Mexico
| | - V M Mena-Burciaga
- Section of Graduate Studies and Research, Escuela Superior de Medicina, Instituto Politécnico Nacional, 11340, Mexico City, Mexico
| | - M D Ronquillo-Sánchez
- Section of Graduate Studies and Research, Escuela Superior de Medicina, Instituto Politécnico Nacional, 11340, Mexico City, Mexico
| | - E Floriano-Sánchez
- Multidisciplinary Research Laboratory, Escuela Militar de Graduados de Sanidad, Secretaría de la Defensa Nacional, 11200, Mexico City, Mexico.
| | - N Cárdenas-Rodríguez
- Laboratory of Neurosciences, Instituto Nacional de Pediatría, 04530, Mexico City, Mexico.
| |
Collapse
|
6
|
Zengin E, Sinning C, Zeller T, Rupprecht HJ, Schnabel RB, Lackner KJ, Blankenberg S, Westermann D, Bickel C. The utility of pregnancy-associated plasma protein A for determination of prognosis in a cohort of patients with coronary artery disease. Biomark Med 2015. [DOI: 10.2217/bmm.15.41] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Background: Pregnancy-associated plasma protein-A (PAPP-A) is discussed as a biomarker representing unstable plaques in coronary artery disease (CAD). Methods: In this study 927 patients with CAD (534 with stable angina and 393 with acute coronary syndrome [ACS]) and 217 patients without CAD and measured PAPP-A levels were included. Follow-up for a median of 5 years was documented. Results: Rising quartiles of PAPP-A concentration had a higher cardiovascular mortality in the overall cohort of patients with CAD (p = 0.002) and the cohort with ACS (p = 0.01). Patients with suspected ACS below the LOD for troponin I but elevated PAPP-A levels had an increased cardiovascular mortality. A cut-off of 11.4 IU/l identified patients with a higher mortality during follow-up. Conclusion: Rising PAPP-A levels are prognostic in patients with CAD. PAPP-A levels were especially predictive in ACS patients with troponin below 10% CV of the 99th percentile for cardiovascular mortality.
Collapse
Affiliation(s)
- Elvin Zengin
- Department of General & Interventional Cardiology, University Heart Center Hamburg, Martinistr. 52, 20246 Hamburg, Germany
| | - Christoph Sinning
- Department of General & Interventional Cardiology, University Heart Center Hamburg, Martinistr. 52, 20246 Hamburg, Germany
| | - Tanja Zeller
- Department of General & Interventional Cardiology, University Heart Center Hamburg, Martinistr. 52, 20246 Hamburg, Germany
| | - Hans-J Rupprecht
- Department of Medicine II, GPR Rüsselsheim, August-Bebel-Straße 59, 65428 Rüsselsheim, Germany
| | - Renate B Schnabel
- Department of General & Interventional Cardiology, University Heart Center Hamburg, Martinistr. 52, 20246 Hamburg, Germany
| | - Karl-J Lackner
- Institute of Clinical Chemistry & Laboratory Medicine, University Medical Center of the Johannes Gutenberg-University Mainz, Langenbeckstraße 1, 55131 Mainz, Germany
| | - Stefan Blankenberg
- Department of General & Interventional Cardiology, University Heart Center Hamburg, Martinistr. 52, 20246 Hamburg, Germany
| | - Dirk Westermann
- Department of General & Interventional Cardiology, University Heart Center Hamburg, Martinistr. 52, 20246 Hamburg, Germany
| | - Christoph Bickel
- Department of Internal Medicine, Federal Armed Forces Central Hospital, Rübenacher Straße 170, 56072 Koblenz, Germany
| | | |
Collapse
|
7
|
Jespersen CHB, Vestergaard KR, Schou M, Teisner B, Goetze JP, Iversen K. Pregnancy-associated plasma protein-A and the vulnerable plaque. Biomark Med 2015; 8:1033-47. [PMID: 25343675 DOI: 10.2217/bmm.14.53] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
For more than a decade, pregnancy-associated plasma protein-A (PAPP-A) has been examined for its relation to acute coronary syndrome (ACS) and the vulnerable plaque. This review summarizes the current knowledge of plasma PAPP-A in relation to nonpregnant individuals focusing on patients with ACS, discusses its use as a possible biomarker for diagnosis and prognosis in ACS, briefly describes the challenges in different assay technologies and describes the effect of heparin administration on PAPP-A concentrations in plasma.
Collapse
|
8
|
Hjortebjerg R, Lindberg S, Hoffmann S, Jensen JS, Oxvig C, Bjerre M, Frystyk J. PAPP-A and IGFBP-4 fragment levels in patients with ST-elevation myocardial infarction treated with heparin and PCI. Clin Biochem 2014; 48:322-8. [PMID: 25489725 DOI: 10.1016/j.clinbiochem.2014.11.022] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Revised: 11/04/2014] [Accepted: 11/27/2014] [Indexed: 02/01/2023]
Abstract
OBJECTIVES Circulating levels of pregnancy-associated plasma protein-A (PAPP-A) predict outcome in patients with acute coronary syndrome (ACS). Unfortunately, administration of heparin to patients with ACS increases circulating PAPP-A, probably by a detachment of PAPP-A from cell surfaces, inducing a considerable bias when using PAPP-A as a biomarker. It remains unknown whether PAPP-A-derived N- and C-terminal fragments of insulin-like growth factor binding protein-4 (NT-IGFBP-4/CT-IGFBP-4) are acutely affected by the increase in PAPP-A. METHODS We prospectively included 78 patients with ST-segment elevation myocardial infarction (STEMI) treated with percutaneous coronary intervention (PCI). Prior to PCI, patients were injected with 10,000IU of unfractionated heparin (UFH). Blood samples were collected immediately before PCI, but after UFH-injection, immediately after PCI and on day 1 and day 2. Plasma IGFBP-4, CT-IGFBP-4 and NT-IGFBP-4 levels were determined by specific, novel immunoassays, and PAPP-A and IGF-I by commercial immunoassays. RESULTS Plasma PAPP-A was strongly elevated upon STEMI, UFH-administration and PCI with mean concentrations (95%-confidence interval) pre-PCI, post-PCI, day 1, and day 2 of 13.0 (11.2;15.2), 14.8 (13.1;16.8), 1.03 (0.90;1.18), and 1.08 (0.92;1.28) μg/L, respectively (p<0.0001). Pre-PCI concentrations of IGFBP-4, CT-IGFBP-4 and NT-IGFBP-4 were 154 (142;166), 53 (47;60) and 136 (122;150) μg/L, and levels were unaltered post-PCI. Concentrations increased on day 1 by 63 (43;87)%, 69 (36;110)%, and 47 (21;79)%, respectively (p<0.0001), i.e. at a time point when PAPP-A levels had normalized. CONCLUSION Plasma IGFBP-4-fragment levels are not acutely altered in patients with STEMI treated with UFH and PCI. Thus, they possess potentials as prognostic markers in ACS patients.
Collapse
Affiliation(s)
- Rikke Hjortebjerg
- Medical Research Laboratory, Department of Clinical Medicine, Faculty of Health, Aarhus University, Aarhus, Denmark; The Danish Diabetes Academy, Odense, Denmark.
| | - Søren Lindberg
- Department of Cardiology P, Gentofte University Hospital, Copenhagen, Denmark
| | - Søren Hoffmann
- Department of Cardiology P, Gentofte University Hospital, Copenhagen, Denmark
| | - Jan S Jensen
- Department of Cardiology P, Gentofte University Hospital, Copenhagen, Denmark; Institute of Clinical Medicine, Faculty of Health Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Claus Oxvig
- Department of Molecular Biology and Genetics, Faculty of Science and Technology, Aarhus University, Aarhus, Denmark
| | - Mette Bjerre
- Medical Research Laboratory, Department of Clinical Medicine, Faculty of Health, Aarhus University, Aarhus, Denmark
| | - Jan Frystyk
- Medical Research Laboratory, Department of Clinical Medicine, Faculty of Health, Aarhus University, Aarhus, Denmark; Department of Endocrinology and Internal Medicine, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
9
|
Sun Y, Chen D, Cao L, Zhang R, Zhou J, Chen H, Li Y, Li M, Cao J, Wang Z. MiR-490-3p modulates the proliferation of vascular smooth muscle cells induced by ox-LDL through targeting PAPP-A. Cardiovasc Res 2013; 100:272-9. [DOI: 10.1093/cvr/cvt172] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
10
|
Wlazeł RN, Rysz J, Paradowski M. Examination of serum pregnancy-associated plasma protein A clinical value in acute coronary syndrome prediction and monitoring. Arch Med Sci 2013; 9:14-20. [PMID: 23515702 PMCID: PMC3598147 DOI: 10.5114/aoms.2013.33343] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2011] [Revised: 11/10/2011] [Accepted: 12/20/2011] [Indexed: 12/23/2022] Open
Abstract
INTRODUCTION Chronic vascular inflammatory process promotes and intensifies all atherogenic events. The aim of this research was to estimate the clinical value of pregnancy-associated plasma protein A (PAPP-A) measurement associated with plaque destabilization and rupture in prediction and monitoring of acute coronary syndromes (ACS) as well as to assess the predictive value of this biomarker in comparison to traditional myocardial infarction (MI) risk markers. MATERIAL AND METHODS The study included 119 patients in 2 investigated groups and one control group. PAPP-A assay was performed using manual ELISA kit, DRG. All other parameters were determined using automatic analyzers: Olympus and Dade Behring. RESULTS A statistically significant difference between PAPP-A concentration median value was found in the investigated group MI individuals' serum and control group individuals' serum (11.42 ng/ml and 7.22 ng/ml respectively, p = 0.003). PAPP-A assay had the highest specificity (83.3%) and sensitivity (53.8%), and therefore the highest clinical value. In patients with clinically and laboratory confirmed MI we proved that PAPP-A serum level is a clinically useful biomarker in ACS prediction, better than C-reactive protein (hsCRP) and fibrinogen (FBG) level. CONCLUSIONS The highest diagnostic efficiency for ACS prediction was proved for simultaneous panel assays consisting of 2-3 parameters (PAPP-A - hsCRP, PAPP-A - FBG, PAPP-A - hsCRP - FBG), while PAPP-A itself does not show characteristics necessary for it to be used as a biomarker for MI dynamic monitoring. It is possible that prothrombotic component is mainly responsible for repeated major adverse cardiac events, more than inflammatory process.
Collapse
Affiliation(s)
- Rafał Nikodem Wlazeł
- Department of Laboratory Medicine and Clinical Biochemistry, Medical University of Lodz, Poland
| | - Jacek Rysz
- Department of Nephrology, Hypertension and Family Medicine, Medical University of Lodz, Poland
| | - Marek Paradowski
- Department of Laboratory Medicine and Clinical Biochemistry, Medical University of Lodz, Poland
| |
Collapse
|
11
|
Woelfle J, Roth CL, Wunsch R, Reinehr T. Pregnancy-associated plasma protein A in obese children: relationship to markers and risk factors of atherosclerosis and members of the IGF system. Eur J Endocrinol 2011; 165:613-22. [PMID: 21753069 DOI: 10.1530/eje-11-0423] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Pregnancy-associated plasma protein A (PAPPA) is a large placenta-derived glycoprotein, which serves as a protease of several IGF-binding proteins (IGFBPs). In non-pregnant adults, measurable PAPPA levels were detected and have been implicated in the pathophysiology of atherosclerotic plaques. However, data in children is lacking. OBJECTIVE To study the relationship between PAPPA, markers of atherosclerosis, and members of the IGF system in pediatric obesity. PATIENTS AND DESIGN Eighty-two obese and 52 nonobese children and 1-year longitudinal follow-up study for obese cohort. INTERVENTION Outpatient 1-year intervention program based on exercise, behavior, and nutrition therapy. MAIN OUTCOME MEASURES Changes in PAPPA levels, carotid intima media thickness (IMT), weight, blood pressure, lipids, metabolic markers, and members of IGF system. RESULTS Baseline PAPPA (PAPPA(BL)) serum levels did not differ between obese and lean subjects. PAPPA(BL) correlated significantly with IGF1, IGFBP1, and serum cholesterol. During the 1-year-program mean IMT decreased from 0.66 ± 0.01 to 0.63 ± 0.01 mm (P<0.05) and PAPPA from 1.83 ± 0.12 to 1.58 ± 0.11 μU/l (P<0.00). In linear regression analysis with IMT after intervention as dependent variable, PAPPA contributed significantly to the observed variance. The longitudinal change of PAPPA correlated significantly with the change of serum triglycerides. CONCLUSION In this cohort of obese children, PAPPA serum levels correlated significantly with other cardiovascular risk factors. The lack of a direct correlation between PAPPA and IMT suggests that the described association of atherosclerotic plaques and increased PAPPA levels might reflect an indirect mechanism of PAPPA with cardiovascular risk factors such as serum lipids rather than a direct effect on the vasculature.
Collapse
Affiliation(s)
- Joachim Woelfle
- Pediatric Endocrinology Division, Children's Hospital, University of Bonn, Adenauerallee 119, 53113 Bonn, Germany.
| | | | | | | |
Collapse
|
12
|
Waks JW, Scirica BM. Established and novel biomarkers in ST-elevation myocardial infarction. Future Cardiol 2011; 7:523-46. [PMID: 21797748 DOI: 10.2217/fca.11.31] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Cardiac biomarkers assist in the diagnosis of and risk stratification in acute coronary syndromes. In ST-elevation myocardial infarction (STEMI), rapid diagnosis and initiation of reperfusion via primary percutaneous coronary intervention or fibrinolysis is often based on the clinical history and presenting ECG, but measurement of biomarkers in the early and/or late phases of STEMI may allow the selection of patients who are at increased or decreased risk of subsequent complications. Although the measurement of only three biomarkers (troponin, natriuretic peptides and C-reactive protein) are currently included in practice guidelines, more than 20 other novel cardiac biomarkers have been proposed to provide improved risk stratification after a STEMI.
Collapse
Affiliation(s)
- Jonathan W Waks
- Department of Medicine, Brigham & Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | | |
Collapse
|
13
|
Shand JA, Menown IB, McEneaney DJ. A timely diagnosis of myocardial infarction. Biomark Med 2010; 4:385-93. [PMID: 20550472 DOI: 10.2217/bmm.10.16] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
The diagnosis of acute myocardial infarction currently rests on the measurement of troponin, a biomarker of myocardial necrosis. Unfortunately, the current generation troponin assays detect troponin only 6-9 h after symptom onset. This can lead to a delay in diagnosis and also excessive resource utilization when triaging patients who, ultimately, have noncardiac causes of acute chest pain. For these reasons, there has been extensive research interest in biomarkers that can detect and rule out myocardial infarction early after symptom onset. These include markers of myocardial injury, such as myoglobin, heart-type fatty acid binding protein, glycogen phosphorylase BB; hemostatic markers, such as D-dimer; and finally, inflammatory markers, such as matrix metalloproteinase 9. Recently, highly sensitive troponin assays have reported an early sensitivity for myocardial infarction of greater than 95%, although at a cost of reduced specificity. The optimal strategy with which to use these novel biomarkers and highly sensitive troponins has yet to be determined, and interpretation of their results in light of thorough clinical assessment remains essential.
Collapse
Affiliation(s)
- J A Shand
- Craigavon Cardiac Centre, Southern Trust, Northern Ireland, UK
| | | | | |
Collapse
|
14
|
Pregnancy-associated plasma protein-A in the pathophysiology, diagnosis, and prognosis of coronary heart disease. COR ET VASA 2010. [DOI: 10.33678/cor.2010.120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
15
|
Biasillo G, Leo M, Della Bona R, Biasucci LM. Inflammatory biomarkers and coronary heart disease: from bench to bedside and back. Intern Emerg Med 2010; 5:225-33. [PMID: 20182820 DOI: 10.1007/s11739-010-0361-1] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2009] [Accepted: 01/25/2010] [Indexed: 10/19/2022]
Abstract
Inflammation plays a pivotal role in all stages of atherosclerosis from endothelial dysfunction and plaque formation to plaque destabilization and disruption. Inflammatory biomarkers, originally studied to better understand the pathophysiology of atherosclerosis, have generated increasing interest among clinicians, because of their utility in the challenging problems of diagnosis and risk assessment of patients with suspected or proved coronary heart disease. Moreover, in fascinating perspective, they could be used as therapeutic target, counteracting initiation, progression, and development of complications of atherosclerosis. In this review, we will provide an overview of the more promising inflammatory biomarkers, focusing on their utility and limitations in the clinical setting.
Collapse
Affiliation(s)
- Gina Biasillo
- Institute of Cardiology, Catholic University of Sacred Heart-Rome, Largo A. Gemelli 8, Rome, Italy
| | | | | | | |
Collapse
|
16
|
Heider P, Pfäffle N, Pelisek J, Wildgruber M, Poppert H, Rudelius M, Eckstein HH. Is Serum Pregnancy-Associated Plasma Protein A Really a Potential Marker of Atherosclerotic Carotid Plaque Stability? Eur J Vasc Endovasc Surg 2010; 39:668-75. [DOI: 10.1016/j.ejvs.2010.03.012] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2009] [Accepted: 03/09/2010] [Indexed: 10/19/2022]
|
17
|
Leukocyte counts, myeloperoxidase, and pregnancy-associated plasma protein a as biomarkers for cardiovascular disease: towards a multi-biomarker approach. Int J Vasc Med 2010; 2010:726207. [PMID: 21188207 PMCID: PMC3003971 DOI: 10.1155/2010/726207] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2010] [Accepted: 03/18/2010] [Indexed: 11/18/2022] Open
Abstract
We evaluated leukocyte counts and levels of CRP, fibrinogen, MPO, and PAPP-A in patients with stable and unstable angina pectoris, acute myocardial infarction, and healthy controls. All biomarkers were analyzed again after 6 months. Leukocyte counts and concentrations of fibrinogen, CRP, MPO, and PAPP-A were significantly increased in patients with acute myocardial infarction. Leukocyte counts and concentrations of MPO were significantly increased in patients with unstable angina pectoris compared with controls. After 6 months, leukocyte counts and MPO concentrations were still increased in patients with acute myocardial infarction when compared to controls. Discriminant analysis showed that leukocyte counts, MPO, and PAPP-A concentrations classified study group designation for acute coronary events correctly in 83% of the cases. In conclusion, combined assessment of leukocyte counts, MPO, and PAPP-A was able to correctly classify acute coronary events, suggesting that this could be a promising panel for a multibiomarker approach to assess cardiovascular risk.
Collapse
|
18
|
Pregnancy associated plasma protein A, a potential marker for vulnerable plaque in patients with non-ST-segment elevation acute coronary syndrome. Clin Biochem 2009; 42:828-34. [DOI: 10.1016/j.clinbiochem.2009.01.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2008] [Revised: 01/10/2009] [Accepted: 01/22/2009] [Indexed: 11/23/2022]
|
19
|
Terkelsen CJ, Oxvig C, Nørgaard BL, Glerup S, Poulsen TS, Lassen JF, Møller HJ, Thuesen L, Falk E, Nielsen TT, Andersen HR. Temporal course of pregnancy-associated plasma protein-A in angioplasty-treated ST-elevation myocardial infarction patients and potential significance of concomitant heparin administration. Am J Cardiol 2009; 103:29-35. [PMID: 19101225 DOI: 10.1016/j.amjcard.2008.08.027] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2008] [Revised: 08/14/2008] [Accepted: 08/14/2008] [Indexed: 10/21/2022]
Abstract
Pregnancy-associated plasma protein-A (PAPP-A) is a putative plaque instability marker. In acute coronary syndromes, the disrupted culprit plaque contains abundant PAPP-A, and circulating PAPP-A levels predict clinical outcomes. Determinants of circulating PAPP-A levels, however, are not fully understood, and the potential role of concomitant heparin administration has not previously been evaluated. The purposes of the present study were to evaluate in-hospital levels of PAPP-A compared with other circulating biomarkers in patients with acute myocardial infarctions and to explore the potential impact of concomitant heparin administration on PAPP-A levels in an animal experiment. Group A comprised 84 patients with ST elevation myocardial infarctions (STEMIs) who were treated with heparin and transferred for primary percutaneous coronary intervention. Plasma samples were obtained at the time of primary percutaneous coronary intervention, twice within the next 24 hours, and subsequently daily during hospitalization. Levels of PAPP-A, troponin T, soluble cluster of differentiation 163, N-terminal-pro-brain natriuretic peptide, and high-sensitivity C-reactive protein were determined. PAPP-A levels were also determined in 2 historical cohorts not given heparin: 14 patients with STEMIs (group B) and 56 patients with non-ST elevation myocardial infarctions (group C). The impact of concomitant heparin administration on the clearance of PAPP-A from the circulation was also explored in mice. In group A, PAPP-A levels were increased in the initial plasma sample in 95% of patients presenting within 3 hours of symptom onset, whereas increased levels of troponin T, soluble cluster of differentiation 163, N-terminal-pro-brain natriuretic peptide, and high-sensitivity C-reactive protein were detectable in 45%, 15%, 50%, and 35% of patients, respectively. Compared with group A, lower levels of PAPP-A were observed in the initial plasma samples drawn in groups B (p = 0.07) and C (p <0.001) not given heparin. In the animal experiment, concomitant heparin administration resulted in increased levels of PAPP-A and delayed clearance of PAPP-A from the circulation. In conclusion, PAPP-A is markedly elevated in the earliest hours after the onset of symptoms in patients with STEMIs treated with heparin and primary percutaneous coronary intervention, and in animal studies, heparin administration is associated with a significant increase in PAPP-A levels, presumably because of the detachment of PAPP-A from the vessel wall. If future studies confirm that concomitant heparin administration also increases PAPP-A levels in humans, the prognostic role of PAPP-A in patients with STEMIs needs to be reevaluated.
Collapse
|
20
|
Consuegra-Sanchez L, Fredericks S, Kaski JC. Pregnancy-associated plasma protein-A (PAPP-A) and cardiovascular risk. Atherosclerosis 2008; 203:346-52. [PMID: 18789800 DOI: 10.1016/j.atherosclerosis.2008.07.042] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2008] [Revised: 07/28/2008] [Accepted: 07/31/2008] [Indexed: 11/30/2022]
Abstract
The search for markers to improve risk prediction for individuals at risk of developing serious cardiovascular events is ongoing. New markers of coronary artery disease progression have been identified in recent years, among which, circulating levels of pregnancy-associated plasma protein-A (PAPP-A) offer an interesting profile. PAPP-A may play a role in the development of atherosclerotic lesions and represent also a marker of atheromatous plaque instability and extent of cardiovascular disease. PAPP-A has been shown to be a marker of adverse outcome in both acute coronary syndrome and stable coronary disease patients. The present article reviews currently available evidence supporting a role for PAPP-A as a marker of cardiovascular risk and discusses some of the pitfalls that may limit its use in clinical practice.
Collapse
|
21
|
Iversen KK, Teisner AS, Teisner B, Kliem A, Thanning P, Grande P, Clemmensen P. Pregnancy associated plasma protein A, a novel, quick, and sensitive marker in ST-elevation myocardial infarction. Am J Cardiol 2008; 101:1389-94. [PMID: 18471447 DOI: 10.1016/j.amjcard.2008.01.015] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2007] [Revised: 01/04/2008] [Accepted: 01/04/2008] [Indexed: 11/24/2022]
Abstract
Traditional biomarkers in acute coronary syndromes reflect myocardial necrosis but not the underlying arteriosclerotic disease. Pregnancy-associated plasma protein A (PAPP-A) is a new biomarker in acute coronary syndromes that detects vulnerable plaques in arteriosclerotic disease and identifies acute coronary syndromes earlier than traditionally used biomarkers. Information regarding circulating PAPP-A levels in patients with ST elevation myocardial infarctions (STEMIs) is limited and contradictory. The aim of the present study was to describe the presence and time-related pattern of circulating PAPP-A levels in patients with STEMIs. Consecutive patients (n = 354) referred for primary percutaneous intervention because of STEMI were included in the study. Blood samples for the analysis of PAPP-A, creatine kinase-MB (CKMB), and troponin T were drawn at admission and every 6 to 8 hours until biomarkers of myocardial necrosis were consistently decreasing. PAPP-A was measured using a newly developed sandwich enzyme-linked immunosorbent assay technique based on 2 monoclonal antibodies. In total, 1,091 PAPP-A, 1,049 troponin T, and 1,016 CKMB samples were analyzed. Mean PAPP-A values at admission were significantly higher in patients with STEMIs than in those with non-ST elevation myocardial infarctions or unstable angina pectoris (27.6 vs 12.2 mIU/L, p <0.01). In samples drawn <2 hours after admission, the sensitivity of PAPP-A was superior (93%) to that of CKMB (60%) and troponin T (61%). In conclusion, PAPP-A levels are elevated in >90% of patients presenting with STEMIs if measured <6 hours after the onset of symptoms or <2 hours of primary percutaneous coronary intervention. In the early stages of STEMI, PAPP-A seems to be a more sensitive marker of myocardial infarction than CKMB and troponin T.
Collapse
|
22
|
Inflammatory and Apoptotic Markers in Ischemic Heart Disease Patients. J Med Biochem 2008. [DOI: 10.2478/v10011-008-0009-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Inflammatory and Apoptotic Markers in Ischemic Heart Disease PatientsIschemic heart disease is the most frequent cause of cardiovascular morbidity and mortality. It is developed on the basis of atherosclerosis which is today considered a chronic inflammatory disease. It is documented by an increase in inflammatory and immune biomarkers, such as C-reactive protein, fibrinogen, neopterin, leukocytes, lymphocytes and others, that are significantly changed in patients with unstable angina or acute myocardial infarction. CRP is mostly studied. Increased concentrations of CRP are associated with a series of risk factors. CRP may predict recurrent events and mortality independently of cardiac troponin levels, and it is also an independent predictor of a cardiovascular event after adjustment for traditional risk factors. Although CRP currently appears to be the most promising biological marker, there is still controversy regarding its use in clinical practice. Both necrotic and apoptotic cell death are documented during atherogenesis, however, limited data are available about apoptotic markers in ischemic heart disease patients. Increasing evidence supports the existence of apoptotic death initiated by ligation of membrane-bound death receptors or by release of cytochrome c from mitochondria, as well as their regulators in the heart. The studies of serum markers show that the apoptotic process is disregulated in ischemic heart disease patients. Tumor necrosis factor-related apoptosis-inducing ligand (TRAIL) is present in stable atherosclerotic lesions, is increased in vulnerable plaques, but its serum levels are reduced significantly in patients with unstable angina. Serum Fas concentrations are increased and FasL are decreased in subjects at high cardiovascular risk. The results of our study show significant changes in serum Fas, FasL, and Bcl-2 concentrations, and lymphocyte caspase-3 activity in different stages of ischemic heart disease. For now, there is evidence that statins are effective in the regulation of some apoptotic markers. The better understanding of the pathways of apoptosis and their regulation is promissing in yielding novel therapeutic targets for cardiovascular disease.
Collapse
|
23
|
Miedema MD, Conover CA, MacDonald H, Harrington SC, Oberg D, Wilson D, Henry TD, Schwartz RS. Pregnancy-associated plasma protein-A elevation in patients with acute coronary syndrome and subsequent atorvastatin therapy. Am J Cardiol 2008; 101:35-9. [PMID: 18157962 DOI: 10.1016/j.amjcard.2007.07.045] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2007] [Revised: 07/13/2007] [Accepted: 07/13/2007] [Indexed: 10/22/2022]
Abstract
Pregnancy-associated plasma protein-A (PAPP-A) was associated with atherosclerotic plaque vulnerability, whereas statin therapy was associated with increased plaque stability. Eighty-six patients presenting with clinical indications (non-ST-elevation myocardial infarction, unstable angina, and stable angina) for invasive coronary angiography and subsequent verified coronary artery disease (CAD) were randomly assigned in a double-blind manner to atorvastatin 10 or 80 mg/day. PAPP-A, high-sensitivity C-reactive protein (hs-CRP), and lipids were measured at baseline (before statin therapy) and at 1 and 6 months. PAPP-A was significantly increased in 35 patients with acute coronary syndrome (ACS) compared with 51 patients with stable CAD (p <0.001). Patients randomly assigned to atorvastatin 10 mg did not show a significant decrease in PAPP-A from baseline at 1 or 6 months. Patients treated with atorvastatin 80 mg showed a significant decrease at 1 month compared with baseline, but not at 6 months. hs-CRP was not significantly different between the ACS and stable CAD groups. Patients receiving atorvastatin 10 mg showed no hs-CRP decrease at 1 or 6 months, whereas it significantly decreased in the 80-mg group at 6 months, but not at 1 month. In conclusion, PAPP-A significantly increased in patients with ACS compared with those with stable coronary disease. High-dose atorvastatin significantly decreased PAPP-A at 1 month and hs-CRP at 6 months in patients with verified CAD. Low-dose atorvastatin did not produce this effect.
Collapse
|
24
|
Rossen M, Iversen K, Teisner A, Teisner B, Kliem A, Grudzinskas G. Optimisation of sandwich ELISA based on monoclonal antibodies for the specific measurement of pregnancy-associated plasma protein (PAPP-A) in acute coronary syndrome. Clin Biochem 2007; 40:478-84. [PMID: 17316591 DOI: 10.1016/j.clinbiochem.2006.11.025] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2006] [Revised: 11/01/2006] [Accepted: 11/22/2006] [Indexed: 10/23/2022]
Abstract
OBJECTIVES PAPP-A has become the principal biochemical serum marker in first trimester screening for Down syndrome, the original data being based on results of a radioimmunoassay (RIA). Recent observations using sandwich ELISA technology have proposed PAPP-A as a potential marker in patients with acute coronary syndrome (ACS). The aims of the present study were to demonstrate (i) the importance of antibody specificity, (ii) the potential pitfalls in changing assay technology, (iii) the importance of strict definition of technology, and (iv) the application of a well-defined assay technology on sera from patients with ACS. DESIGN AND METHODS Candidate monoclonal antibodies (Mab) were identified by immunohistochemistry, Western blot and the absence of positive signals (ELISA) with normal, non-pregnant serum as antigen source. The ELISA technology was standardized against the original PAPP-A RIA and the WHO reference preparation (WHO 78/610). Results different from those obtained by the original RIA led to ELISA modifications with respect to dilution buffer and enzymatic digestion of the Mab. RESULTS The first generation ELISA revealed serum measurements from a pool of non-pregnant (n=103) individuals which, compared to the RIA, seemed to be false positive. The false positive reaction was abolished by addition of bovine serum (BS) to the dilution buffer. Subsequent analysis of individual sera (n=103) indicated that 7/103 were still false positive. This reaction was eliminated by introduction of F(ab')(2)-fragment of the indicator antibody. This modified ELISA revealed that serum PAPP-A levels in ACS were statistically significantly higher than in controls (p<0.001). Moreover, serum PAPP-A in ACS patients with ST-segment elevation (STEMI) were higher (p<0.001) compared to patients without ST-segment elevation (NSTEMI). Immunohistochemical analysis failed to identify PAPP-A in the atherosclerotic plaques.
Collapse
Affiliation(s)
- Marie Rossen
- Immunology and Microbiology, University of Southern Denmark, Odense, Denmark
| | | | | | | | | | | |
Collapse
|
25
|
Qin QP, Wittfooth S, Pettersson K. Measurement and clinical significance of circulating PAPP-A in ACS patients. Clin Chim Acta 2007; 380:59-67. [PMID: 17376420 DOI: 10.1016/j.cca.2007.02.036] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2006] [Revised: 02/08/2007] [Accepted: 02/17/2007] [Indexed: 11/19/2022]
Abstract
BACKGROUND The rupture of coronary atherosclerotic plaque and subsequent thrombus formation are major events underlying acute coronary syndromes (ACS). Pregnancy associated plasma protein A (PAPP-A), a biomarker of plaque rupture, has been studied in patients with ACS. This review aimed to provide an overview of clinical utility of PAPP-A in ACS patients and analytical issues adhering to immunological PAPP-A measurement. METHODS The literature relating to PAPP-A in ACS, the molecular structure and immunodetection of PAPP-A was reviewed. PubMed was used to search the relevant articles published from 1974 to 2006. RESULTS Higher PAPP-A concentrations have been found in patients with ACS than in patients with stable angina and subjects without coronary artery disease. Elevated PAPP-A concentrations have also been shown to associate with adverse cardiac events in ACS patients. The prognostic value of PAPP-A appears to be independent of cardiac troponins. Noteworthy, the PAPP-A form that accounts for increase in ACS is uncomplexed with the proform of eosinophil major basic protein (proMBP). However, PAPP-A assays applied in clinical studies published thus far detect total PAPP-A. Consequently, the clinical value may be non-optimal when total PAPP-A is measured in ACS patients. In addition, the clinical value can also be affected by the analytical factors that exert an effect on the performance of PAPP-A assays. CONCLUSIONS PAPP-A appears to be a very promising biomarker useful in the clinical management of ACS patients. However, more prospective and interventional studies with carefully established immunoassays are required to validate its clinical utility.
Collapse
Affiliation(s)
- Qiu-Ping Qin
- Innotrac Diagnostics, Biolinja 12, 20750 Turku, Finland.
| | | | | |
Collapse
|
26
|
Boldt HB, Conover CA. Pregnancy-associated plasma protein-A (PAPP-A): a local regulator of IGF bioavailability through cleavage of IGFBPs. Growth Horm IGF Res 2007; 17:10-18. [PMID: 17218136 DOI: 10.1016/j.ghir.2006.11.003] [Citation(s) in RCA: 137] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Pregnancy-associated plasma protein-A (PAPP-A) was originally isolated in 1974, as one of four proteins of placental origin found in high concentrations in the blood of pregnant women. In the early 1990s several laboratories reported novel protease activity against insulin-like growth factor binding protein-4 (IGFBP-4) in media conditioned by several cell types. This activity was unique, as it appeared to require the presence of IGF to cleave IGFBP-4. In 1999, this IGF-dependent IGFBP-4 protease activity was isolated from human fibroblast conditioned media and identified as PAPP-A. Subsequently, PAPP-A was shown to be expressed by a variety of cell types, and thus no longer could be considered to be just "pregnancy-associated". This review will describe what is currently known about the structure of PAPP-A and about its function as an IGFBP protease, with a focus on new insights obtained through study of a PAPP-A knock-out mouse model and on potential clinical applications.
Collapse
Affiliation(s)
- Henning B Boldt
- Division of Endocrinology, Metabolism, and Nutrition, Department of Internal Medicine, Mayo Clinic College of Medicine, 200 First Street SW, 5-194 Joseph, Rochester, MN 55905, USA
| | | |
Collapse
|
27
|
Body R, Ferguson C. Towards evidence-based emergency medicine: best BETs from the Manchester Royal Infirmary. Pregnancy-associated plasma protein A: a novel cardiac marker with promise. Emerg Med J 2006; 23:875-7. [PMID: 17057147 PMCID: PMC2464389 DOI: 10.1136/emj.2006.042184] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
28
|
Wittfooth S, Qin QP, Lund J, Tierala I, Pulkki K, Takalo H, Pettersson K. Immunofluorometric Point-of-Care Assays for the Detection of Acute Coronary Syndrome-Related Noncomplexed Pregnancy-Associated Plasma Protein A. Clin Chem 2006; 52:1794-801. [PMID: 16809398 DOI: 10.1373/clinchem.2006.070607] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractBackground: We recently reported that the pregnancy-associated plasma protein A (PAPP-A) form specifically related to acute coronary syndromes (ACS) is not complexed with the proform of eosinophil major basic protein (proMBP). The aim of this study was to develop rapid point-of-care immunoassays for the measurement of the noncomplexed PAPP-A.Methods: We developed immunofluorometric noncompetitive dry-reagent assays for total PAPP-A with 2 PAPP-A subunit-specific monoclonal antibodies and for PAPP-A/proMBP complex with 1 PAPP-A subunit-specific antibody and 1 proMBP subunit-specific antibody. The concentration of noncomplexed PAPP-A was determined as the difference of the results obtained with the 2 assays.Results: The assays were linear from 0.5 to 300 mIU/L. The analytical detection limit and functional detection limit (CV <20%) were 0.18 mIU/L and 0.27 mIU/L for total PAPP-A assay and 0.23 mIU/L and 0.70 mIU/L for PAPP-A/proMBP assay, respectively. The total assay imprecisions were <10%, and recoveries were 88%–107% for both assays. The mean difference (95% limits of agreement) between the new total PAPP-A assay and a previously reported total PAPP-A assay was −3.2% (−45.7% to 39.3%; n = 546; P = 0.0019). In serum samples from 159 non-ACS individuals, median concentrations (interquartile range) were 2.42 (1.14) mIU/L for total PAPP-A, 2.20 (1.18) mIU/L for PAPP-A/proMBP, and 0.18 (0.63) mIU/L for noncomplexed PAPP-A. Total PAPP-A and PAPP-A/proMBP, but not noncomplexed PAPP-A, correlated with age (r = 0.290, P = 0.0002; r = 0.230, P = 0.0035; r = 0.075, P = 0.3483, respectively).Conclusions: The new assays described revealed that noncomplexed PAPP-A is found only in negligible amounts in non-ACS samples.
Collapse
Affiliation(s)
- Saara Wittfooth
- Department of Biotechnology,, University of Turku, Turku, Finland.
| | | | | | | | | | | | | |
Collapse
|
29
|
Fredericks S, Bertomeu-Gonzalez V, Petrovic I, Holt DW, Kaski JC. Comment on Immunoassays Developed for Pregnancy-Associated Plasma Protein-A (PAPP-A) in Pregnancy May Not Recognize PAPP-A in Acute Coronary Syndromes. Clin Chem 2006; 52:1619-20. [PMID: 16873310 DOI: 10.1373/clinchem.2006.074138] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
30
|
Qin QP, Kokkala S, Lund J, Tamm N, Qin X, Lepäntalo M, Pettersson K. Immunoassays Developed for Pregnancy-Associated Plasma Protein-A (PAPP-A) in Pregnancy May Not Recognize PAPP-A in Acute Coronary Syndromes. Clin Chem 2006; 52:398-404. [PMID: 16423908 DOI: 10.1373/clinchem.2005.058396] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractBackground: Pregnancy-associated plasma protein-A (PAPP-A) concentrations are increased in the circulation of patients with acute coronary syndromes (ACS) and are associated with future adverse cardiac events. PAPP-A in ACS differs from PAPP-A in pregnancy in that PAPP-A in ACS is not complexed with the proform of eosinophil major basic protein (proMBP). We investigated the effect of antibody selection on the utility of PAPP-A assays for measurement of PAPP-A in pregnancy and/or ACS, and whether immunoassays for PAPP-A in pregnancy are suitable for PAPP-A in ACS.Methods: We constructed 2-site sandwich time-resolved immunofluorometric assays using 22 monoclonal antibodies raised against pregnancy serum PAPP-A. All antibodies were studied in pairs, with each antibody used as either capture or tracer. We compared the reactivity of each antibody combination with PAPP-A/proMBP complex derived from pregnancy sera or with uncomplexed PAPP-A extracted from atherosclerotic plaques. Recombinant human PAPP-A and proMBP were also used to determine the specificity of the antibodies. We confirmed all major findings with serum samples collected from patients with myocardial infarction.Results: Six monoclonal antibodies reacted with the proMBP subunit of the PAPP-A/proMBP complex. Epitopes of 3 proMBP-reactive antibodies largely overlapped, but were well separated from those of another group of 3 proMBP-reactive antibodies. Assays using any of the 6 proMBP-reactive antibodies failed to detect PAPP-A in ACS. In addition, some 2-site assays capable of detecting PAPP-A in pregnancy were almost incapable of detecting PAPP-A in ACS, although the individual epitopes remained detectable in PAPP-A in ACS.Conclusions: Immunoassays developed for PAPP-A in pregnancy may not be suitable for PAPP-A in ACS. Assays for PAPP-A in ACS should be based on careful antibody selection and subjected to extensive testing with clinical ACS samples.
Collapse
Affiliation(s)
- Qiu-Ping Qin
- Department of Biotechnology, University of Turku, Turku, Finland.
| | | | | | | | | | | | | |
Collapse
|
31
|
Piñón P, Carlos Kaski J. Inflamación, aterosclerosis y riesgo cardiovascular: PAPP-A, Lp-PLA2 y cistatina C. ¿Nuevas aportaciones o información redundante? Rev Esp Cardiol 2006. [DOI: 10.1157/13086082] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
32
|
Laterza OF. PAPP-A: a marker of plaque instability. Is it ready for prime time? Future Cardiol 2005; 1:495-500. [PMID: 19804150 DOI: 10.2217/14796678.1.4.495] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Pregnancy-associated plasma protein-A (PAPP-A) is a zinc-binding metalloproteinase that was first identified circulating in the serum of pregnant women, but has recently been suggested to be a predictor of risk for cardiovascular events. Publications on PAPP-A, primarily from the last 4-5 years, were reviewed extensively. A special emphasis was placed on those that address the development of methods for the detection of PAPP-A in human serum/plasma and those that study the diagnostic/prognostic accuracy of PAPP-A in patients with acute coronary syndrome. This review shall focus on the possible mechanism of action of PAPP-A, clinical studies involving PAPP-A, PAPP-A assays and its molecular structure. All clinical studies to date related to the diagnostic/prognostic accuracy of PAPP-A (a total of eight studies) were included. They suggest that elevations in PAPP-A correlate with higher risk for the development of cardiovascular adverse events. However, there are conflicting data as to whether PAPP-A levels correlate with cardiac troponins or C-reactive protein. Thus, there is room for speculation as to whether PAPP-A is involved in inflammatory processes, and as to what its role is in plaque rupture and subsequent cardiac ischemic events. Furthermore, new insights into the molecular structure of PAPP-A could aid in the development of more specific assays that may help unravel the clinical utility of PAPP-A.
Collapse
Affiliation(s)
- Omar F Laterza
- Merck Research Laboratories, Merck & Co., Inc. RY50-100, PO Box 2000, Rahway, NJ 07065-0900, USA.
| |
Collapse
|