1
|
Sun W, Huang A, Wen S, Kong Q, Liu X. Investigation into temporal changes in the human bloodstain lipidome. Int J Legal Med 2025; 139:303-317. [PMID: 39249528 DOI: 10.1007/s00414-024-03330-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Accepted: 09/02/2024] [Indexed: 09/10/2024]
Abstract
Bloodstains are crucial pieces of physical evidences found at violent crime scenes, providing valuable information for reconstructing forensic cases. However, there is limited data on how bloodstain lipidomes change over time after deposition. Hence, we deployed a high-throughput high-performance liquid chromatography-mass spectrometry (HPLC-MS) approach to construct lipidomic atlases of bloodstains, whole blood, plasma, and blood cells from 15 healthy adults. A time-course analysis was also performed on bloodstains deposited for up to 6 months at room temperature (~ 25°C). The molecular levels of 60 out of 400 detected lipid species differed dramatically between bloodstain and whole blood samples, with major disturbances observed in membrane glycerophospholipids. More than half of these lipids were prevalent in the cellular and plasmic fractions; approximately 27% and 10% of the identified lipids were uniquely derived from blood cells and plasma, respectively. Furthermore, a subset of 65 temporally dynamic lipid species arose across the 6-month room-temperature deposition period, with decreased triacylglycerols (TAGs) and increased lysophosphatidylcholines (LPCs) as representatives, accounting for approximately 8% of the total investigated lipids. The instability of lipids increased linearly with time, with the most variability observed in the first 10 days. This study sheds light on the impact of air-drying bloodstains on blood components at room temperature and provides a list of potential bloodstain lipid markers for determining the age of bloodstains.
Collapse
Affiliation(s)
- Weifen Sun
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Ministry of Justice, Shanghai, 200063, China
- Shanghai Institute of Hematology, State Key Laboratory of Medical Genomics, National Research Center for Translational Medicine at Shanghai, Ruijin Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Ao Huang
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Ministry of Justice, Shanghai, 200063, China
- Department of Forensic Science, Medical School of Soochow University, Suzhou, 215123, China
| | - Shubo Wen
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Ministry of Justice, Shanghai, 200063, China
- Department of Forensic Science, Medical School of Soochow University, Suzhou, 215123, China
| | - Qianqian Kong
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Ministry of Justice, Shanghai, 200063, China
| | - Xiling Liu
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Ministry of Justice, Shanghai, 200063, China.
| |
Collapse
|
2
|
Nixon R, Ip THR, Jenkins B, Yip PK, Clarke P, Ponnusamy V, Michael-Titus AT, Koulman A, Shah DK. Lipid Profiles from Dried Blood Spots Reveal Lipidomic Signatures of Newborns Undergoing Mild Therapeutic Hypothermia after Hypoxic-Ischemic Encephalopathy. Nutrients 2021; 13:4301. [PMID: 34959853 PMCID: PMC8703828 DOI: 10.3390/nu13124301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 11/24/2021] [Accepted: 11/24/2021] [Indexed: 11/16/2022] Open
Abstract
Hypoxic-ischemic encephalopathy (HIE) is associated with perinatal brain injury, which may lead to disability or death. As the brain is a lipid-rich organ, various lipid species can be significantly impacted by HIE and these correlate with specific changes to the lipidomic profile in the circulation. Objective: To investigate the peripheral blood lipidomic signature in dried blood spots (DBS) from newborns with HIE. Using univariate analysis, multivariate analysis and sPLS-DA modelling, we show that newborns with moderate-severe HIE (n = 46) who underwent therapeutic hypothermia (TH) displayed a robust peripheral blood lipidomic signature comprising 29 lipid species in four lipid classes; namely phosphatidylcholine (PC), lysophosphatidylcholine (LPC), triglyceride (TG) and sphingomyelin (SM) when compared with newborns with mild HIE (n = 18). In sPLS-DA modelling, the three most discriminant lipid species were TG 50:3, TG 54:5, and PC 36:5. We report a reduction in plasma TG and SM and an increase in plasma PC and LPC species during the course of TH in newborns with moderate-severe HIE, compared to a single specimen from newborns with mild HIE. These findings may guide the research in nutrition-based intervention strategies after HIE in synergy with TH to enhance neuroprotection.
Collapse
Affiliation(s)
- Rebekah Nixon
- The Royal London Hospital, Barts Health NHS Trust, London E1 1FR, UK; (R.N.); (T.H.R.I.)
- Centre for Neuroscience, Surgery and Trauma, Blizard Institute, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London E1 2AT, UK; (P.K.Y.); (A.T.M.-T.)
| | - Ting Hin Richard Ip
- The Royal London Hospital, Barts Health NHS Trust, London E1 1FR, UK; (R.N.); (T.H.R.I.)
- Centre for Neuroscience, Surgery and Trauma, Blizard Institute, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London E1 2AT, UK; (P.K.Y.); (A.T.M.-T.)
| | - Benjamin Jenkins
- NIHR Core Metabolomics and Lipidomics Laboratory, Wellcome Trust-MRC Institute of Metabolic Science, Addenbrooke’s Hospital, University of Cambridge, Cambridge CB2 0QQ, UK;
| | - Ping K. Yip
- Centre for Neuroscience, Surgery and Trauma, Blizard Institute, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London E1 2AT, UK; (P.K.Y.); (A.T.M.-T.)
| | - Paul Clarke
- Neonatal Unit, Norfolk and Norwich University Hospitals NHS Foundation Trust, Norwich NR4 7UY, UK;
- Norwich Medical School, University of East Anglia, Norwich NR4 7UY, UK
| | - Vennila Ponnusamy
- Ashford and St. Peter’s Hospitals NHS Foundation Trust, Chertsey KT16 0PZ, UK;
| | - Adina T. Michael-Titus
- Centre for Neuroscience, Surgery and Trauma, Blizard Institute, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London E1 2AT, UK; (P.K.Y.); (A.T.M.-T.)
| | - Albert Koulman
- NIHR Core Metabolomics and Lipidomics Laboratory, Wellcome Trust-MRC Institute of Metabolic Science, Addenbrooke’s Hospital, University of Cambridge, Cambridge CB2 0QQ, UK;
| | - Divyen K. Shah
- The Royal London Hospital, Barts Health NHS Trust, London E1 1FR, UK; (R.N.); (T.H.R.I.)
- Centre for Neuroscience, Surgery and Trauma, Blizard Institute, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London E1 2AT, UK; (P.K.Y.); (A.T.M.-T.)
| |
Collapse
|
3
|
Lim MD. Dried Blood Spots for Global Health Diagnostics and Surveillance: Opportunities and Challenges. Am J Trop Med Hyg 2018; 99:256-265. [PMID: 29968557 PMCID: PMC6090344 DOI: 10.4269/ajtmh.17-0889] [Citation(s) in RCA: 131] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Accepted: 05/02/2018] [Indexed: 12/28/2022] Open
Abstract
There is increasing interest in using dried blood spot (DBS) cards to extend the reach of global health and disease surveillance programs to hard-to-reach populations. Conceptually, DBS offers a cost-effective solution for multiple use cases by simplifying logistics for collecting, preserving, and transporting blood specimens in settings with minimal infrastructure. This review describes methods to determine both the reliability of DBS-based bioanalysis for a defined use case and the optimal conditions that minimize pre-analytical sources of data variability. Examples by the newborn screening, drug development, and global health communities are provided in this review of published literature. Sources of variability are linked in most cases, emphasizing the importance of field-to-laboratory standard operating procedures that are evidence based and consider both stability and efficiency of recovery for a specified analyte in defining the type of DBS card, accessories, handling procedures, and storage conditions. Also included in this review are reports where DBS was determined to not be feasible because of technology limitations or physiological properties of a targeted analyte.
Collapse
Affiliation(s)
- Mark D. Lim
- Global Health Division, Bill & Melinda Gates Foundation, Seattle, Washington
| |
Collapse
|
4
|
Eyskens F, Devos S. Newborn Screening for Lysosomal Storage Disorders in Belgium. JOURNAL OF INBORN ERRORS OF METABOLISM AND SCREENING 2017. [DOI: 10.1177/2326409817744231] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Affiliation(s)
- Francois Eyskens
- Provinciaal Centrum voor Opsporing Metabole Ziekten, Antwerp, Belgium
| | - Sylvie Devos
- Provinciaal Centrum voor de Opsporing van Metabole Aandoeningen, Antwerp, Belgium
| |
Collapse
|
5
|
Abstract
Started in 1963 by Robert Guthrie, newborn screening (NBS) is considered to be one of the great public health achievements. Its original goal was to screen newborns for conditions that could benefit from presymptomatic treatment, thereby reducing associated morbidity and mortality. With advances in technology, the number of disorders included in NBS programs increased. Pompe disease is a good candidate for NBS. Because decisions regarding which diseases should be included in NBS panels are made regionally and locally, programs and efforts for NBS for Pompe disease have been inconsistent both in the United States and globally. In this article, published in the "Newborn Screening, Diagnosis, and Treatment for Pompe Disease" guidance supplement, the Pompe Disease Newborn Screening Working Group, an international group of experts in both NBS and Pompe disease, review the methods used for NBS for Pompe disease and summarize results of current and ongoing NBS programs in the United States and other countries. Challenges and potential drawbacks associated with NBS also are discussed.
Collapse
Affiliation(s)
- Olaf A Bodamer
- Division of Genetics and Genomics, Boston Children's Hospital, Boston, Massachusetts;
| | - C Ronald Scott
- Division of Molecular Medicine, Department of Pediatrics, University of Washington, Seattle, Washington; and
| | - Roberto Giugliani
- Medical Genetics Service, Hospital de Clinicas de Porto Alegre (HCPA) and Department of Genetics, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, Brazil
| | | |
Collapse
|
6
|
Lukacs Z, Barr M, Hamilton J. Best practice in the measurement and interpretation of lysosomal acid lipase in dried blood spots using the inhibitor Lalistat 2. Clin Chim Acta 2017; 471:201-205. [PMID: 28532785 DOI: 10.1016/j.cca.2017.05.027] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Revised: 05/18/2017] [Accepted: 05/19/2017] [Indexed: 01/01/2023]
Abstract
Lysosomal acid lipase deficiency (LAL-D) is an inherited, autosomal recessive lysosomal storage disorder characterized by progressive damage in multiple organ systems. Diagnosis is especially important in infants, in whom the course of disease is rapidly lethal without treatment. The recent regulatory approval of recombinant human lysosomal acid lipase (LAL), sebelipase alfa, merits rapid diagnosis in clinical routine, particularly in infants. A method for measuring LAL activity in dried blood spot (DBS) samples using the highly specific LAL inhibitor Lalistat 2 is available. This method is shown to effectively discriminate between individuals with LAL-D and unaffected controls. With the increase in DBS LAL testing since the original publication of this method, a need to optimise assay performance has been identified. Here, we describe refinements to the DBS assay, including technical modifications, quality control measures and best-practice guidance for interpreting and reporting results. Particular attention is paid to alternatives to the use of mercuric chloride as the stop reagent and the choice of excitation wavelength for 4-methylumbelliferone palmitate under assay conditions at pH4.0. In addition, a simpler method of reporting results is proposed using cutoffs based on percentage mean normal enzyme activity.
Collapse
Affiliation(s)
- Zoltan Lukacs
- Newborn Screening and Metabolic Diagnostics Unit, Hamburg University Medical Centre, Martinistr. 52, 20246 Hamburg, Germany.
| | - Marianne Barr
- Biochemistry Department, Queen Elizabeth University Hospital, 1345 Govan Road, Glasgow G51 4TF, United Kingdom.
| | - John Hamilton
- Biochemistry Department, Queen Elizabeth University Hospital, 1345 Govan Road, Glasgow G51 4TF, United Kingdom.
| |
Collapse
|
7
|
Breier AC, Cé J, Mezzalira J, Daitx VV, Moraes VC, Goldim MPS, Coelho JC. Alpha-l-iduronidase and arylsulfatase B in dried blood spots on filter paper: Biochemical parameters and time stability. Clin Biochem 2017; 50:431-435. [PMID: 28088454 DOI: 10.1016/j.clinbiochem.2016.12.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2016] [Revised: 12/22/2016] [Accepted: 12/22/2016] [Indexed: 10/20/2022]
Abstract
BACKGROUND The goal of this study was to assess the biochemical parameters of the enzymes α-l-iduronidase (IDUA) and arylsulfatase B (ASB), which are deficient in mucopolysaccharidosis (MPS) I and VI, respectively, in dried blood spot (DBS) samples impregnated on filter paper. METHODS AND RESULTS The optimal pH, Km, and Vmax of IDUA and ASB in DBS are hereby presented. After these analyses, the reference values for the activities of these enzymes in DBS with cutoff of 3.65nmol/h/mL for IDUA and 6.80nmol/h/mL for ASB were established. The research also showed that the stability (21days) of the IDUA activity is lower than ASB, which maintained its enzymatic activity stable up until 60days of analysis, after impregnating the filter paper with blood. CONCLUSION Currently, DBS ensures important advantages in handling storage and transportation of samples with respect to neonatal screening programs. This study contributes to characterizing and differentiating the biochemistry of deficient enzymes in MPSs I and VI of DBS samples.
Collapse
Affiliation(s)
- Ana Carolina Breier
- Postgraduate Program, Biochemistry Department, Lysosomal Storage Diseases Laboratory, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS, Brazil.
| | - Jaqueline Cé
- Postgraduate Program, Biochemistry Department, Lysosomal Storage Diseases Laboratory, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS, Brazil
| | - Jamila Mezzalira
- Postgraduate Program, Biochemistry Department, Lysosomal Storage Diseases Laboratory, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS, Brazil
| | - Vanessa V Daitx
- Postgraduate Program, Biochemistry Department, Lysosomal Storage Diseases Laboratory, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS, Brazil
| | - Vitoria C Moraes
- Postgraduate Program, Biochemistry Department, Lysosomal Storage Diseases Laboratory, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS, Brazil
| | - Mariana P S Goldim
- Postgraduate Program, Biochemistry Department, Lysosomal Storage Diseases Laboratory, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS, Brazil
| | - Janice C Coelho
- Postgraduate Program, Biochemistry Department, Lysosomal Storage Diseases Laboratory, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS, Brazil
| |
Collapse
|
8
|
Wagner M, Tonoli D, Varesio E, Hopfgartner G. The use of mass spectrometry to analyze dried blood spots. MASS SPECTROMETRY REVIEWS 2016; 35:361-438. [PMID: 25252132 DOI: 10.1002/mas.21441] [Citation(s) in RCA: 162] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Dried blood spots (DBS) typically consist in the deposition of small volumes of capillary blood onto dedicated paper cards. Comparatively to whole blood or plasma samples, their benefits rely in the fact that sample collection is easier and that logistic aspects related to sample storage and shipment can be relatively limited, respectively, without the need of a refrigerator or dry ice. Originally, this approach has been developed in the sixties to support the analysis of phenylalanine for the detection of phenylketonuria in newborns using bacterial inhibition test. In the nineties tandem mass spectrometry was established as the detection technique for phenylalanine and tyrosine. DBS became rapidly recognized for their clinical value: they were widely implemented in pediatric settings with mass spectrometric detection, and were closely associated to the debut of newborn screening (NBS) programs, as a part of public health policies. Since then, sample collection on paper cards has been explored with various analytical techniques in other areas more or less successfully regarding large-scale applications. Moreover, in the last 5 years a regain of interest for DBS was observed and originated from the bioanalytical community to support drug development (e.g., PK studies) or therapeutic drug monitoring mainly. Those recent applications were essentially driven by improved sensitivity of triple quadrupole mass spectrometers. This review presents an overall view of all instrumental and methodological developments for DBS analysis with mass spectrometric detection, with and without separation techniques. A general introduction to DBS will describe their advantages and historical aspects of their emergence. A second section will focus on blood collection, with a strong emphasis on specific parameters that can impact quantitative analysis, including chromatographic effects, hematocrit effects, blood effects, and analyte stability. A third part of the review is dedicated to sample preparation and will consider off-line and on-line extractions; in particular, instrumental designs that have been developed so far for DBS extraction will be detailed. Flow injection analysis and applications will be discussed in section IV. The application of surface analysis mass spectrometry (DESI, paper spray, DART, APTDCI, MALDI, LDTD-APCI, and ICP) to DBS is described in section V, while applications based on separation techniques (e.g., liquid or gas chromatography) are presented in section VI. To conclude this review, the current status of DBS analysis is summarized, and future perspectives are provided.
Collapse
Affiliation(s)
- Michel Wagner
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Life Sciences Mass Spectrometry, Quai Ernest-Ansermet 30, 1211, Geneva, Switzerland
| | - David Tonoli
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Life Sciences Mass Spectrometry, Quai Ernest-Ansermet 30, 1211, Geneva, Switzerland
| | - Emmanuel Varesio
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Life Sciences Mass Spectrometry, Quai Ernest-Ansermet 30, 1211, Geneva, Switzerland
| | - Gérard Hopfgartner
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Life Sciences Mass Spectrometry, Quai Ernest-Ansermet 30, 1211, Geneva, Switzerland
| |
Collapse
|
9
|
Orsini JJ, Kay DM, Saavedra-Matiz CA, Wenger DA, Duffner PK, Erbe RW, Biski C, Martin M, Krein LM, Nichols M, Kurtzberg J, Escolar ML, Adams DJ, Arnold GL, Iglesias A, Galvin-Parton P, Kronn DF, Kwon JM, Levy PA, Pellegrino JE, Shur N, Wasserstein MP, Caggana M. Newborn screening for Krabbe disease in New York State: the first eight years' experience. Genet Med 2016; 18:239-48. [PMID: 26795590 DOI: 10.1038/gim.2015.211] [Citation(s) in RCA: 72] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2015] [Accepted: 12/14/2015] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Krabbe disease (KD) results from galactocerebrosidase (GALC) deficiency. Infantile KD symptoms include irritability, progressive stiffness, developmental delay, and death. The only potential treatment is hematopoietic stem cell transplantation. New York State (NYS) implemented newborn screening for KD in 2006. METHODS Dried blood spots from newborns were assayed for GALC enzyme activity using mass spectrometry, followed by molecular analysis for those with low activity (≤12% of the daily mean). Infants with low enzyme activity and one or more mutations were referred for follow-up diagnostic testing and neurological examination. RESULTS Of >1.9 million screened, 620 infants were subjected to molecular analysis and 348 were referred for diagnostic testing. Five had enzyme activities and mutations consistent with infantile KD and manifested clinical/neurodiagnostic abnormalities. Four underwent transplantation, two are surviving with moderate to severe handicaps, and two died from transplant-related complications. The significance of many sequence variants identified is unknown. Forty-six asymptomatic infants were found to be at moderate to high risk for disease. CONCLUSIONS The positive predictive value of KD screening in NYS is 1.4% (5/346) considering confirmed infantile cases. The incidence of infantile KD in NYS is approximately 1 in 394,000, but it may be higher for later-onset forms.
Collapse
Affiliation(s)
- Joseph J Orsini
- Laboratory of Human Genetics, Wadsworth Center, New York State Department of Health, Albany, New York, USA
| | - Denise M Kay
- Laboratory of Human Genetics, Wadsworth Center, New York State Department of Health, Albany, New York, USA
| | - Carlos A Saavedra-Matiz
- Laboratory of Human Genetics, Wadsworth Center, New York State Department of Health, Albany, New York, USA
| | - David A Wenger
- Lysosomal Diseases Testing Laboratory, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Patricia K Duffner
- Hunter James Kelly Research Institute, University of Buffalo, Buffalo, New York, USA
| | - Richard W Erbe
- Department of Pediatrics, Women and Children's Hospital of Buffalo, Buffalo, New York, USA
| | - Chad Biski
- Laboratory of Human Genetics, Wadsworth Center, New York State Department of Health, Albany, New York, USA
| | - Monica Martin
- Laboratory of Human Genetics, Wadsworth Center, New York State Department of Health, Albany, New York, USA
| | - Lea M Krein
- Laboratory of Human Genetics, Wadsworth Center, New York State Department of Health, Albany, New York, USA
| | - Matthew Nichols
- Laboratory of Human Genetics, Wadsworth Center, New York State Department of Health, Albany, New York, USA
| | - Joanne Kurtzberg
- Department of Pediatrics, Duke University School of Medicine, Durham, North Carolina, USA
| | - Maria L Escolar
- University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania, USA
| | - Darius J Adams
- Division of Genetics, Department of Pediatrics, Albany Medical Center, Albany, New York, USA.,Genetics and Metabolism, Goryeb Children's Hospital, Atlantic Health System, Morristown, New Jersey, USA
| | - Georgianne L Arnold
- University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania, USA.,Department of Pediatrics, University of Rochester Medical Center, Rochester, New York, USA
| | - Alejandro Iglesias
- Department of Pediatrics, Columbia University Medicine Center, New York, New York, USA
| | - Patricia Galvin-Parton
- Department of Pediatrics, University Medical Center at Stony Brook, Stony Brook, New York, USA
| | - David F Kronn
- Department of Pediatrics, New York Medical College, Valhalla, New York, USA
| | - Jennifer M Kwon
- Department of Pediatrics, University of Rochester Medical Center, Rochester, New York, USA
| | - Paul A Levy
- Department of Pediatrics, Children's Hospital at Montefiore, Bronx, New York, USA
| | - Joan E Pellegrino
- Department of Pediatrics, Upstate Medical University, Syracuse, New York, USA
| | - Natasha Shur
- Division of Genetics, Department of Pediatrics, Albany Medical Center, Albany, New York, USA
| | | | - Michele Caggana
- Laboratory of Human Genetics, Wadsworth Center, New York State Department of Health, Albany, New York, USA
| | | |
Collapse
|
10
|
Verma J, Thomas DC, Sharma S, Jhingan G, Singh A, Hsiao KJ, Schoonderwoerd K, Puri RD, Verma IC. Inherited metabolic disorders: Quality management for laboratory diagnosis. Clin Chim Acta 2015; 447:1-7. [DOI: 10.1016/j.cca.2015.04.040] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2014] [Revised: 04/30/2015] [Accepted: 04/30/2015] [Indexed: 10/23/2022]
|
11
|
Gucciardi A, Legnini E, Di Gangi IM, Corbetta C, Tomanin R, Scarpa M, Giordano G. A column-switching HPLC-MS/MS method for mucopolysaccharidosis type I analysis in a multiplex assay for the simultaneous newborn screening of six lysosomal storage disorders. Biomed Chromatogr 2014; 28:1131-9. [PMID: 24449175 DOI: 10.1002/bmc.3133] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2013] [Revised: 11/21/2013] [Accepted: 12/16/2013] [Indexed: 11/07/2022]
Abstract
Lysosomal storage disorders comprise a group of rare genetic diseases in which a deficit of specific hydrolases leads to the storage of undegraded substrates in lysosomes. Impaired enzyme activities can be assessed by MS/MS quantification of the reaction products obtained after incubation with specific substrates. In this study, a column-switching HPLC-MS/MS method for multiplex screening in dried blood spot of the lysosomal enzymes activities was developed. Mucopolysaccharidosis type I, Fabry, Gaucher, Krabbe, Niemann-Pick A/B and Pompe diseases were simultaneously assayed. Dried blood spots were incubated with substrates and internal standards; thereafter, supernatants were collected with minor manipulations. Samples were injected, trapped into an online perfusion column and, by a six-port valve, switched online through the C18 analytical column to perform separation of metabolites followed by MS/MS analysis. A total of 1136 de-identified newborn screening samples were analyzed to determine references for enzymes activity values. As positive controls, we analyzed dried blood spots from three patients with Pompe, one with Fabry, one with Krabbe disease and two with MPS I, and in all cases the enzyme activities were below the cutoff values measured for newborns, except for an MPS I patient after successful hematopoietic stem cell transplantation.
Collapse
Affiliation(s)
- Antonina Gucciardi
- Mass Spectrometry Laboratory, Department of Women's and Children's Health, University of Padova, Italy
| | | | | | | | | | | | | |
Collapse
|
12
|
Adam BW, Chafin DL, De Jesús VR. Stabilities of hemoglobins A and S in dried blood spots stored under controlled conditions. Clin Biochem 2013; 46:1089-1092. [PMID: 23701845 PMCID: PMC4557610 DOI: 10.1016/j.clinbiochem.2013.05.043] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Revised: 05/02/2013] [Accepted: 05/06/2013] [Indexed: 11/24/2022]
Abstract
OBJECTIVE We aimed to measure separately the contributions of heat and humidity to changes in levels of hemoglobins A and S in dried-blood-spot (DBS) samples. DESIGN AND METHODS We stored paired sets of DBSs at 37°C for predetermined intervals in low-humidity and high-humidity environments. Hemoglobin A and S levels of all samples in each complete set were measured in a single high performance liquid chromatography run. RESULTS During the one-month storage intervals, both hemoglobin species lost about 35% of initial levels in low-humidity storage and almost all of initial levels in high-humidity storage. CONCLUSIONS Minimizing both humidity and temperature in the transportation and storage environments of DBS samples is essential to maintaining the integrity of the hemoglobin tetramer molecules.
Collapse
Affiliation(s)
- Barbara W Adam
- Centers for Disease Control and Prevention (CDC), 4770 Buford Highway NE, Atlanta, GA 30341, USA.
| | - Dana L Chafin
- Centers for Disease Control and Prevention (CDC), 4770 Buford Highway NE, Atlanta, GA 30341, USA
| | - Victor R De Jesús
- Centers for Disease Control and Prevention (CDC), 4770 Buford Highway NE, Atlanta, GA 30341, USA
| |
Collapse
|