1
|
Thurston M, Peltoniemi M, Giangrande A, Vujaklija I, Botter A, Kulmala JP, Piitulainen H. High-density EMG reveals atypical spatial activation of the gastrocnemius during walking in adolescents with Cerebral Palsy. J Electromyogr Kinesiol 2024; 79:102934. [PMID: 39378587 DOI: 10.1016/j.jelekin.2024.102934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 06/06/2024] [Accepted: 09/18/2024] [Indexed: 10/10/2024] Open
Abstract
Children with Cerebral Palsy (CP) exhibit less-selective, simplified muscle activation during gait due to injury of the developing brain. Abnormal motor unit recruitment, altered excitation-inhibition balance, and muscle morphological changes all affect the CP electromyogram. High-density surface electromyography (HDsEMG) has potential to reveal novel manifestations of CP neuromuscular pathology and functional deficits by assessing spatiotemporal details of myoelectric activity. We used HDsEMG to investigate spatial-EMG distribution and temporal-EMG complexity of gastrocnemius medialis (GM) muscle during treadmill walking in 11 adolescents with CP and 11 typically developed (TD) adolescents. Our results reveal more-uniform spatial-EMG amplitude distribution across the GM in adolescents with CP, compared to distal emphasis in TD adolescents. More-uniform spatial-EMG was associated with stronger ankle co-contraction and spasticity. CP adolescents exhibited a non-significant trend towards elevated EMG-temporal complexity. Homogenous spatial distribution and disordered temporal evolution of myoelectric activity in CP suggests less-structured and desynchronized recruitment of GM motor units, in combination with muscle morphological changes. Using HDsEMG, we uncovered novel evidence of atypical spatiotemporal activation during gait in CP, opening paths towards deeper understanding of motor control deficits and better characterization of changes in muscular activation from interventions.
Collapse
Affiliation(s)
- Maxwell Thurston
- Faculty of Sport and Health Sciences, Neuromuscular Research Center, University of Jyväskylä, Jyväskylä, Finland; Motion Laboratory, New Children's Hospital, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.
| | - Mika Peltoniemi
- Faculty of Sport and Health Sciences, Neuromuscular Research Center, University of Jyväskylä, Jyväskylä, Finland; Motion Laboratory, New Children's Hospital, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| | - Alessandra Giangrande
- Faculty of Sport and Health Sciences, Neuromuscular Research Center, University of Jyväskylä, Jyväskylä, Finland; Laboratory for Engineering of the Neuromuscular System (LISiN), Department of Electronics and Telecommunication, Politecnico di Torino, Turin, Italy; PoliToBIOMed Laboratory, Politecnico di Torino, Turin, Italy
| | - Ivan Vujaklija
- Department of Electrical Engineering and Automation, Aalto University, Espoo, Finland
| | - Alberto Botter
- Laboratory for Engineering of the Neuromuscular System (LISiN), Department of Electronics and Telecommunication, Politecnico di Torino, Turin, Italy; PoliToBIOMed Laboratory, Politecnico di Torino, Turin, Italy
| | - Juha-Pekka Kulmala
- Motion Laboratory, New Children's Hospital, Helsinki University Hospital and University of Helsinki, Helsinki, Finland; School of Health and Social Studies, JAMK University of Applied Sciences, Jyväskylä, Finland
| | - Harri Piitulainen
- Faculty of Sport and Health Sciences, Neuromuscular Research Center, University of Jyväskylä, Jyväskylä, Finland; Motion Laboratory, New Children's Hospital, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| |
Collapse
|
2
|
Li D, Sun N, Xiang L, Liu J, Wang X, Yang L, Huang S. Neurophysiological Characteristics in Type II and Type III 5q Spinal Muscular Atrophy Patients: Impact of Nusinersen Treatment. Drug Des Devel Ther 2024; 18:953-965. [PMID: 38562520 PMCID: PMC10984209 DOI: 10.2147/dddt.s449066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 03/21/2024] [Indexed: 04/04/2024] Open
Abstract
Objective This study aimed to observe the neurophysiological characteristics of type II and type III 5q spinal muscular atrophy (SMA) patients and the changes in peripheral motor nerve electrophysiology after Nusinersen treatment, as well as the influencing factors. Methods This single-center retrospective case-control study collected clinical data and peripheral motor nerve CMAP parameters from 42 5qSMA patients and 42 healthy controls at the Second Affiliated Hospital of Xi'an Jiaotong University (January 2021 to December 2022). It evaluated changes in motor function and CMAP amplitude before and after Nusinersen treatment. Results Our investigation encompassed all symptomatic and genetically confirmed SMA patients, consisting of 32 type II and 10 type III cases, with a median age of 57 months (29.5 to 96 months). Comparative analysis with healthy controls revealed substantial reductions in CMAP amplitudes across various nerves in both type II and type III patients. Despite the administration of Nusinersen treatment for 6 or 14 months to the entire cohort, discernible alterations in motor nerve amplitudes were not observed, except for a significant improvement in younger patients (≤36 months) at the 14-month mark. Further scrutiny within the type II subgroup unveiled that individuals with a disease duration ≤12 months experienced a noteworthy upswing in femoral nerve amplitude, a statistically significant difference when compared to those with >12 months of disease duration. Conclusion Motor nerve amplitudes were significantly decreased in type II and type III 5q SMA patients compared to healthy controls. Nusinersen treatment showed better improvement in motor nerve amplitudes in younger age groups and those with shorter disease duration, indicating a treatment-time dependence.
Collapse
Affiliation(s)
- Dan Li
- Department of Pediatrics, the Second Affiliated Hospital of Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Na Sun
- Department of Pediatrics, the Second Affiliated Hospital of Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Li Xiang
- Department of Neurology, the Second Affiliated Hospital of Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Jingjie Liu
- Department of Neurology, the Second Affiliated Hospital of Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Xueying Wang
- Department of Pediatrics, the Second Affiliated Hospital of Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Lin Yang
- Department of Pediatrics, the Second Affiliated Hospital of Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Shaoping Huang
- Department of Pediatrics, the Second Affiliated Hospital of Xi’an Jiaotong University, Xi’an, People’s Republic of China
| |
Collapse
|
3
|
Guneidy RA, Zaki ER, Karim GSAA, Saleh NS, Shokeer A. Adverse effect of Tamarindus indica and tamoxifen combination on redox balance and genotoxicity of breast cancer cell. J Genet Eng Biotechnol 2023; 21:131. [PMID: 37987952 PMCID: PMC10663423 DOI: 10.1186/s43141-023-00564-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 10/26/2023] [Indexed: 11/22/2023]
Abstract
BACKGROUND Breast cancer is the most significant threat to women worldwide. Most chemotherapeutic drugs cause cancer cell death and apoptosis by inducing oxidative stress and producing reactive oxygen species (ROS). Cancer cells have a higher rate of metabolic activity than normal cells and thus produce more ROS. Glutathione and its related enzymes are the most significant antioxidant defense mechanisms that protect cells from oxidative and chemotherapeutic impacts. The anticancer actions of phenolic compounds were greatly confirmed. Using phenolic compounds as drugs in combination with chemotherapy may improve health, improve treatment outcomes, and reduce dose and damage. The goal of the study was to treat breast cancer cell lines (MCF-7) with Tamarindus indica extract individually and in combination with the anticancer drug tamoxifen (TAM) to improve therapeutic efficacy. RESULTS After 48 h of incubation at IC25 concentrations of T. indica extract (47.3 g/mL), tamoxifen (0.8 g/mL), and their co-treatments, the biochemical and genotoxic effects on MCF-7 cell lines were investigated. In MCF7 cell lines, T. indica extract increased reduced glutathione levels as well as glutathione transferase, glutathione peroxidase, and glutathione reductase activities. The same was true for oxidative state indicators, where higher levels of catalase and lactate dehydrogenase activity were associated with higher levels of malondialdehyde. T. indica has almost no effect on the DNA damage parameters. All of these variations can produce alterations in cancer cell genotoxicity and apoptotic pathways, explaining the restoration of DNA moment to normal levels and enhanced survival. CONCLUSION Cytotoxic and genotoxic effect of treatment with T. indica extract could be attributed to the dynamic interaction of glutathione cycle and antioxidant enzymes to combat oxidative stress, which can be considered as a positive therapeutic effect. On the other hand, the negative response of tamoxifen efficacy when co-treated with T. indica reversed tamoxifen's genotoxicity and enhanced survival.
Collapse
Affiliation(s)
- R A Guneidy
- Department of Molecular Biology, Biotechnology Research Institute, National Research Centre, Cairo, Egypt.
| | - E R Zaki
- Department of Molecular Biology, Biotechnology Research Institute, National Research Centre, Cairo, Egypt
| | - G S A Abdel Karim
- Department of Molecular Biology, Biotechnology Research Institute, National Research Centre, Cairo, Egypt
| | - N S Saleh
- Department of Molecular Biology, Biotechnology Research Institute, National Research Centre, Cairo, Egypt
| | - A Shokeer
- Department of Molecular Biology, Biotechnology Research Institute, National Research Centre, Cairo, Egypt
| |
Collapse
|
4
|
Sørensen DM, Bostock H, Abrahao A, Alaamel A, Alaydin HC, Ballegaard M, Boran E, Cengiz B, de Carvalho M, Dunker Ø, Fuglsang-Frederiksen A, Graffe CC, Jones KE, Kallio M, Kalra S, Krarup C, Krøigård T, Liguori R, Lupescu T, Maitland S, Matamala JM, Moldovan M, Moreno-Roco J, Nilsen KB, Phung L, Santos MO, Themistocleous AC, Uysal H, Vacchiano V, Whittaker RG, Zinman L, Tankisi H. Estimating motor unit numbers from a CMAP scan: Repeatability study on three muscles at 15 centres. Clin Neurophysiol 2023; 151:92-99. [PMID: 37236129 DOI: 10.1016/j.clinph.2023.04.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 03/16/2023] [Accepted: 04/15/2023] [Indexed: 05/28/2023]
Abstract
OBJECTIVE To assess the repeatability and suitability for multicentre studies of MScanFit motor unit number estimation (MUNE), which involves modelling compound muscle action potential (CMAP) scans. METHODS Fifteen groups in 9 countries recorded CMAP scans twice, 1-2 weeks apart in healthy subjects from abductor pollicis brevis (APB), abductor digiti minimi (ADM) and tibialis anterior (TA) muscles. The original MScanFit program (MScanFit-1) was compared with a revised version (MScanFit-2), designed to accommodate different muscles and recording conditions by setting the minimal motor unit size as a function of maximum CMAP. RESULTS Complete sets of 6 recordings were obtained from 148 subjects. CMAP amplitudes differed significantly between centres for all muscles, and the same was true for MScanFit-1 MUNE. With MScanFit-2, MUNE differed less between centres but remained significantly different for APB. Coefficients of variation between repeats were 18.0% for ADM, 16.8% for APB, and 12.1% for TA. CONCLUSIONS It is recommended for multicentre studies to use MScanFit-2 for analysis. TA provided the least variable MUNE values between subjects and the most repeatable within subjects. SIGNIFICANCE MScanFit was primarily devised to model the discontinuities in CMAP scans in patients and is less suitable for healthy subjects with smooth scans.
Collapse
Affiliation(s)
- D M Sørensen
- Department of Clinical Neurophysiology, Aarhus University Hospital, Denmark
| | - H Bostock
- UCL Queen Square Institute of Neurology, Queen Square, London, United Kingdom
| | - A Abrahao
- Department of Medicine, University of Toronto, Toronto, Canada
| | - A Alaamel
- Department of Neurology, Akdeniz University Hospital, Antalya, Turkey
| | - H C Alaydin
- Department of Neurology, Gazi University, Ankara, Turkey
| | - M Ballegaard
- Department of Clinical Neurology, Zealand University Hospital, Roskilde, Denmark
| | - E Boran
- Department of Neurology, Gazi University, Ankara, Turkey
| | - B Cengiz
- Department of Neurology, Gazi University, Ankara, Turkey
| | - M de Carvalho
- Faculty of Medicine, iMM, Centro de Estudos Egas Moniz, Universidade de Lisboa, Department of Neurosciences and Mental Health, CHULN, Lisbon, Portugal
| | - Ø Dunker
- Department of Neurology and Department of Research and Innovation, Division of Clinical Neuroscience, Oslo University Hospital, Norway
| | - A Fuglsang-Frederiksen
- Department of Clinical Neurophysiology, Aarhus University Hospital, Denmark; Department of Clinical Institute, Aarhus University, Aarhus, Denmark
| | - C C Graffe
- Department of Clinical Neurophysiology, Rigshospitalet, Copenhagen, Denmark
| | - K E Jones
- Neuroscience and Mental Health Institute, University of Alberta, Edmonton, Canada
| | - M Kallio
- Department of Clinical Neurophysiology, Oulu University Hospital, Oulu, Finland
| | - S Kalra
- Neuroscience and Mental Health Institute, University of Alberta, Edmonton, Canada
| | - C Krarup
- Department of Clinical Neurophysiology, Rigshospitalet, Copenhagen, Denmark
| | - T Krøigård
- Department of Neurology, Odense University Hospital, Denmark
| | - R Liguori
- Dipertimento di Scienze Biomediche e Neuromotorie, Università di Bologna, Bologna, Italy
| | - T Lupescu
- Department of Neurology, Agrippa Ionescu Hospital, Bucharest, Romania
| | - S Maitland
- Translational and Clinical Research Institute, Newcastle University, United Kingdom
| | - J M Matamala
- Translational Neurology and Neurophysiology Lab, Department of Neurological Sciences and Biomedical Neuroscience Institute, University of Chile, Santiago, Chile
| | - M Moldovan
- Department of Clinical Neurophysiology, Rigshospitalet, Copenhagen, Denmark
| | - J Moreno-Roco
- Translational Neurology and Neurophysiology Lab, Department of Neurological Sciences and Biomedical Neuroscience Institute, University of Chile, Santiago, Chile
| | - K B Nilsen
- Department of Neurology and Department of Research and Innovation, Division of Clinical Neuroscience, Oslo University Hospital, Norway
| | - L Phung
- Department of Medicine, University of Toronto, Toronto, Canada
| | - M O Santos
- Faculty of Medicine, iMM, Centro de Estudos Egas Moniz, Universidade de Lisboa, Department of Neurosciences and Mental Health, CHULN, Lisbon, Portugal
| | - A C Themistocleous
- Nuffield Department of Clinical Neurosciences University of Oxford, Oxford, United Kingdom
| | - H Uysal
- Department of Medicine, University of Toronto, Toronto, Canada
| | - V Vacchiano
- Dipertimento di Scienze Biomediche e Neuromotorie, Università di Bologna, Bologna, Italy
| | - R G Whittaker
- Translational and Clinical Research Institute, Newcastle University, United Kingdom
| | - L Zinman
- UCL Queen Square Institute of Neurology, Queen Square, London, United Kingdom
| | - H Tankisi
- Department of Clinical Neurophysiology, Aarhus University Hospital, Denmark; Department of Clinical Institute, Aarhus University, Aarhus, Denmark.
| |
Collapse
|
5
|
Al‐Zuhairy A, Jakobsen J, Moldovan M, Krarup C. Axonal loss at time of diagnosis as biomarker for long-term disability in chronic inflammatory demyelinating polyneuropathy. Muscle Nerve 2022; 66:715-722. [PMID: 36217677 PMCID: PMC9828077 DOI: 10.1002/mus.27722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 08/16/2022] [Accepted: 08/27/2022] [Indexed: 01/12/2023]
Abstract
INTRODUCTION/AIMS We hypothesized that early, pretreatment axonal loss would predict long-term disability, supported by a pilot study of selected patients with chronic inflammatory demyelinating polyneuropathy (CIDP). To further test this hypothesis, we examined a larger consecutive group of CIDP patients. METHODS Needle electromyography and motor and sensory nerve conduction studies were carried out in 30 CIDP patients at pretreatment and follow-up 5 to 28 years later. Changes in amplitudes were expressed as axonal Z scores and changes in conduction as demyelination Z scores and correlated with findings of the Inflammatory Rasch-built Overall Disability Scale (I-RODS), the Neuropathy Impairment Score (NIS), and isokinetic dynamometry (IKS). RESULTS At follow-up, the median I-RODS score was 73, the NIS was 23, and the IKS was 56%. The median axonal Z score was unchanged at follow-up. Conversely, the corresponding demyelination Z scores improved. The initial axonal loss was correlated with the clinical outcome and was an independent predictor of outcome by multivariate regression analysis. Axonal loss at follow-up was also correlated with the clinical outcome. Only the follow-up demyelination Z score was correlated with the clinical outcomes. Furthermore, the latency until treatment initiation was predictive of all three clinical outcome scores at follow-up, and of axonal loss and demyelination at follow-up. DISCUSSION The present study findings indicate that pretreatment axonal loss at diagnosis in CIDP is predictive of long-term disability, neurological impairment, and strength. A delay in treatment is associated with more pronounced axonal loss and a worse clinical outcome.
Collapse
Affiliation(s)
- Ali Al‐Zuhairy
- Department of NeurologyCopenhagen University Hospital, RigshospitaletCopenhagenDenmark
| | - Johannes Jakobsen
- Department of NeurologyCopenhagen University Hospital, RigshospitaletCopenhagenDenmark
| | - Mihai Moldovan
- Department of Clinical NeurophysiologyRigshospitalet and Department of Neuroscience, University of CopenhagenCopenhagenDenmark
| | - Christian Krarup
- Department of Clinical NeurophysiologyRigshospitalet and Department of Neuroscience, University of CopenhagenCopenhagenDenmark
| |
Collapse
|
6
|
Nandedkar SD, Barkhaus PE, V Stålberg E. Analysis of the compound muscle action potential scan: Step Index (STEPIX) and Amplitude Index (AMPIX). Clin Neurophysiol 2022; 139:119-127. [DOI: 10.1016/j.clinph.2022.04.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 03/24/2022] [Accepted: 04/11/2022] [Indexed: 11/29/2022]
|
7
|
Stikvoort García DJL, Kovalchuk MO, Goedee HS, van Schelven LJ, van den Berg LH, Franssen H, Sleutjes BTHM. Motor unit integrity in multifocal motor neuropathy: A systematic evaluation with CMAP scans. Muscle Nerve 2021; 65:317-325. [PMID: 34854491 PMCID: PMC9300115 DOI: 10.1002/mus.27469] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Revised: 11/18/2021] [Accepted: 11/23/2021] [Indexed: 11/09/2022]
Abstract
Introduction/Aims Progressive axonal loss in multifocal motor neuropathy (MMN) is often assessed with nerve conduction studies (NCS), by recording maximum compound muscle action potentials (CMAPs). However, reinnervation maintains the CMAP amplitude until a significant portion of the motor unit (MU) pool is lost. Therefore, we performed more informative CMAP scans to study MU characteristics in a large cohort of patients with MMN. Methods We derived the maximum CMAP amplitude (CMAPmax), an MU number estimate (MUNE), and the largest MU amplitude stimulus current required to elicit 5%, 50%, and 95% of CMAPmax (S5, S50, S95) and relative ranges ([S95 − S5] × 100 / S50) from the scans. These metrics were compared with clinical, laboratory, and NCS results. Results Forty MMN patients and 24 healthy controls were included in the study. CMAPmax and MUNE were reduced in MMN patients (both P < .001). Largest MU amplitude as a percentage of CMAPmax was increased in MMN patients (P < .001). Disease duration and treatment duration were not associated with MUNE. Relative range was larger in patients with anti‐GM1 antibodies than in those without anti‐GM1 antibodies (P = .016) and controls (P < .001). The largest MU amplitudes were larger in patients without anti‐GM1 antibodies than in patients with anti‐GM1 antibodies (P = .037) and controls (P = .044). Discussion We found that MU loss is common in MMN and accompanied by enlarged MUs. Presence of anti‐GM1 antibodies was associated with increased relative range of MU thresholds and reduction in largest MU amplitude. Our findings indicate that CMAP scans complement routine NCS, and may have potential for practical monitoring of treatment efficacy and disease progression.
Collapse
Affiliation(s)
| | - Maria O Kovalchuk
- Department of Neurology, Brain Centre Utrecht, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - H Stephan Goedee
- Department of Neurology, Brain Centre Utrecht, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Leonard J van Schelven
- Department of Medical Technology and Clinical Physics, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Leonard H van den Berg
- Department of Neurology, Brain Centre Utrecht, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Hessel Franssen
- Department of Neurology, Brain Centre Utrecht, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Boudewijn T H M Sleutjes
- Department of Neurology, Brain Centre Utrecht, University Medical Centre Utrecht, Utrecht, The Netherlands
| |
Collapse
|
8
|
Sleutjes BTHM, Bystrup Jacobsen A, Tankisi H, Gorkem Sirin N, Emre Oge A, Henderson RD, van Doorn PA, van den Berg LH, van Eijk RPA. Advancing disease monitoring of amyotrophic lateral sclerosis with the compound muscle action potential scan. Clin Neurophysiol 2021; 132:3152-3159. [PMID: 34749234 DOI: 10.1016/j.clinph.2021.09.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 08/20/2021] [Accepted: 09/15/2021] [Indexed: 11/17/2022]
Abstract
OBJECTIVE To determine which compound muscle action potential (CMAP) scan-derived electrophysiological markers are most sensitive for monitoring disease progression in amyotrophic lateral sclerosis (ALS), and whether they hold value for clinical trials. METHODS We used four independent patient cohorts to assess longitudinal patterns of a comprehensive set of electrophysiological markers including their association with the ALS functional rating scale (ALSFRS-R). Results were translated to trial sample size requirements. RESULTS In 65 patients, 225 thenar CMAP scan recordings were obtained. Electrophysiological markers showed extensive variation in their longitudinal trajectories. Expressed as standard deviations per month, motor unit number estimation (MUNE) values declined by 0.09 (CI 0.07-0.12), D50, a measure that quantifies CMAP scan discontinuities, declined by 0.09 (CI 0.06-0.13) and maximum CMAP by 0.05 (CI 0.03-0.08). ALSFRS-R declined fastest (0.12, CI 0.08 - 0.15), however the between-patient variability was larger compared to electrophysiological markers, resulting in larger sample sizes. MUNE reduced the sample size by 19.1% (n = 388 vs n = 314) for a 6-month study compared to the ALSFRS-R. CONCLUSIONS CMAP scan-derived markers show promise in monitoring disease progression in ALS patients, where MUNE may be its most suitable derivate. SIGNIFICANCE MUNE may increase clinical trial efficiency compared to clinical endpoints.
Collapse
Affiliation(s)
- Boudewijn T H M Sleutjes
- Department of Neurology, Brain Centre Utrecht, Utrecht, the Netherlands; Department of Neurology, Erasmus Medical Center Rotterdam, Rotterdam, the Netherlands.
| | | | - Hatice Tankisi
- Department of Clinical Neurophysiology, Aarhus University Hospital, Aarhus, Denmark
| | - N Gorkem Sirin
- Department of Neurology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey
| | - A Emre Oge
- Department of Neurology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey
| | - Robert D Henderson
- Department of Neurology, Royal Brisbane & Women's Hospital, Brisbane, Australia
| | - Pieter A van Doorn
- Department of Neurology, Erasmus Medical Center Rotterdam, Rotterdam, the Netherlands
| | | | - Ruben P A van Eijk
- Department of Neurology, Brain Centre Utrecht, Utrecht, the Netherlands; Biostatistics and Research Support, Julius Centre for Health Sciences and Primary Care, University Medical Centre Utrecht, Utrecht, the Netherlands
| |
Collapse
|
9
|
Kang JH. Quantitative Analysis of Electrophysiological Characteristics of CIDP and CMT Type 1: Sensory Nerve Research. KOREAN JOURNAL OF CLINICAL LABORATORY SCIENCE 2021. [DOI: 10.15324/kjcls.2021.53.2.151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Affiliation(s)
- Ji-Hyuk Kang
- Department of Biomedical Laboratory Science, College of Health and Medical Science, Daejeon University, Daejeon, Korea
| |
Collapse
|
10
|
Model-Based Analysis of Muscle Strength and EMG-Force Relation with respect to Different Patterns of Motor Unit Loss. Neural Plast 2021; 2021:5513224. [PMID: 34257638 PMCID: PMC8245245 DOI: 10.1155/2021/5513224] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 05/02/2021] [Accepted: 06/01/2021] [Indexed: 01/07/2023] Open
Abstract
This study presents a model-based sensitivity analysis of the strength of voluntary muscle contraction with respect to different patterns of motor unit loss. A motor unit pool model was implemented including simulation of a motor neuron pool, muscle force, and surface electromyogram (EMG) signals. Three different patterns of motor unit loss were simulated, including (1) motor unit loss restricted to the largest ones, (2) motor unit loss restricted to the smallest ones, and (3) motor unit loss without size restriction. The model outputs including muscle force amplitude, variability, and the resultant EMG-force relation were quantified under two different motor neuron firing strategies. It was found that motor unit loss restricted to the largest ones had the most dominant impact on muscle strength and significantly changed the EMG-force relation, while loss restricted to the smallest motor units had a pronounced effect on force variability. These findings provide valuable insight toward our understanding of the neurophysiological mechanisms underlying experimental observations of muscle strength, force control, and EMG-force relation in both normal and pathological conditions.
Collapse
|
11
|
Sleutjes BTHM, Ruisch J, Nassi TE, Buitenweg JR, van Schelven LJ, van den Berg LH, Franssen H, Stephan Goedee H. Impact of stimulus duration on motor unit thresholds and alternation in compound muscle action potential scans. Clin Neurophysiol 2021; 132:323-331. [PMID: 33450554 DOI: 10.1016/j.clinph.2020.10.026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 09/30/2020] [Accepted: 10/26/2020] [Indexed: 11/17/2022]
Abstract
OBJECTIVE To investigate the impact of stimulus duration on motor unit (MU) thresholds and alternation within compound muscle action potential (CMAP) scans. METHODS The stimulus duration (0.1, 0.2, 0.6, and 1.0 ms) in thenar CMAP scans and individual MUs of 14 healthy subjects was systematically varied. We quantified variability of individual MU's thresholds by relative spread (RS), MU thresholds by stimulus currents required to elicit target CMAPs of 5% (S5), 50% (S50) and 95% (S95) of the maximum CMAP, and relative range (RR) by 100*[S95-S5]/S50. We further assessed the strength-duration time constant (SDTC). Experimental observations were subsequently simulated to quantify alternation. RESULTS RS, unaffected by stimulus duration, was 1.65% averaged over all recordings. RR increased for longer stimulus duration (11.4% per ms, p < 0.001). SDTC shortened with higher target CMAPs (0.007 ms per 10% CMAP, p < 0.001). Experiments and simulations supported that this may underlie the increased RR. A short compared to long stimulus duration recruited relative more MUs at S50 (more alternation) than at the tails (less alternation). CONCLUSIONS The stimulus duration significantly affects MU threshold distribution and alternation within CMAP scans. SIGNIFICANCE Stimulation settings can be further optimized and their standardization is preferred when using CMAP scans for monitoring neuromuscular diseases.
Collapse
Affiliation(s)
- Boudewijn T H M Sleutjes
- Department of Neurology, Brain Centre Utrecht, University Medical Centre Utrecht, Utrecht, the Netherlands.
| | - Janna Ruisch
- Biomedical Signals and Systems, Technical Medical Centre, University of Twente, Enschede, the Netherlands
| | - Thijs E Nassi
- Biomedical Signals and Systems, Technical Medical Centre, University of Twente, Enschede, the Netherlands
| | - Jan R Buitenweg
- Biomedical Signals and Systems, Technical Medical Centre, University of Twente, Enschede, the Netherlands
| | - Leonard J van Schelven
- Department of Medical Technology and Clinical Physics, University Medical Center Utrecht, the Netherlands
| | - Leonard H van den Berg
- Department of Neurology, Brain Centre Utrecht, University Medical Centre Utrecht, Utrecht, the Netherlands
| | - Hessel Franssen
- Department of Neurology, Brain Centre Utrecht, University Medical Centre Utrecht, Utrecht, the Netherlands
| | - H Stephan Goedee
- Department of Neurology, Brain Centre Utrecht, University Medical Centre Utrecht, Utrecht, the Netherlands
| |
Collapse
|
12
|
The pathophysiology of stress urinary incontinence: a systematic review and meta-analysis. Int Urogynecol J 2021; 32:501-552. [PMID: 33416968 PMCID: PMC8053188 DOI: 10.1007/s00192-020-04622-9] [Citation(s) in RCA: 43] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Accepted: 11/16/2020] [Indexed: 01/15/2023]
Abstract
Introduction and hypothesis To evaluate the evidence for pathologies underlying stress urinary incontinence (SUI) in women. Methods For the data sources, a structured search of the peer-reviewed literature (English language; 1960–April 2020) was conducted using predefined key terms in PubMed and Embase. Google Scholar was also searched. Peer-reviewed manuscripts that reported on anatomical, physiological or functional differences between females with signs and/or symptoms consistent with SUI and a concurrently recruited control group of continent females without any substantive urogynecological symptoms. Of 4629 publications screened, 84 met the inclusion criteria and were retained, among which 24 were included in meta-analyses. Results Selection bias was moderate to high; < 25% of studies controlled for major confounding variables for SUI (e.g., age, BMI and parity). There was a lack of standardization of methods among studies, and several measurement issues were identified. Results were synthesized qualitatively, and, where possible, random-effects meta-analyses were conducted. Deficits in urethral and bladder neck structure and support, neuromuscular and mechanical function of the striated urethral sphincter (SUS) and levator ani muscles all appear to be associated with SUI. Meta-analyses showed that observed bladder neck dilation and lower functional urethral length, bladder neck support and maximum urethral closure pressures are strong characteristic signs of SUI. Conclusion The pathology of SUI is multifactorial, with strong evidence pointing to bladder neck and urethral incompetence. While there is also evidence of impaired urethral support and levator ani function, standardized approaches to measurement are needed to generate higher levels of evidence.
Collapse
|
13
|
Okhovat AA, Advani S, Moradi K, Ziaadini B, Panahi A, Nafissi S, Haghi Ashtiani B, Fatehi F. Application of CMAP scan for the evaluation of patients with chronic inflammatory demyelinating polyneuropathy: a prospective study. Neurophysiol Clin 2021; 51:175-181. [PMID: 33423829 DOI: 10.1016/j.neucli.2020.12.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 12/26/2020] [Accepted: 12/26/2020] [Indexed: 11/28/2022] Open
Abstract
AIMS We aimed to assess the compound muscle action potential (CMAP) scan in the follow-up of chronic inflammatory demyelinating polyneuropathy (CIDP) patients and investigate the correlation of CMAP scan parameters with functional and standard electrodiagnostic tests. METHODS We evaluated four parameters of abductor pollicis brevis (APB) CMAP scan (i.e., step numbers, step percentage, S10, S90), functional measures (e.g., Medical Research Council Sum Scores), and electrodiagnostic tests, including nerve conduction study (NCS) and motor NCS of the median nerve in the baseline and after six months of treatment. RESULTS Twenty patients completed baseline clinical and electrodiagnostic studies. However, sixteen patients completed the follow-up study. The median of step numbers at baseline was 3.5 (2-4.2), which decreased to 2.5 (0-3) (p = 0.005). After the treatment, step percentage reduced from 28.6 (23.9-38.7) to 13.4 (0-23.6) (p = 0.001). The scores obtained from the clinical scales showed significant recovery of most of the functions, while the alterations of NCSS and NCS of the median nerve were not significant. CONCLUSIONS We found a significant reduction in step number and step percentage after follow-up. This alteration was not reflected in standard electrodiagnostic values. The improvement of functional scales alongside the CMAP scan parameters suggests that the CMAP scan could be considered an appropriate outcome measurement in research and clinical fields.
Collapse
Affiliation(s)
- Ali Asghar Okhovat
- Neurology Department, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Soroor Advani
- Neurology Department, Shohada Tajrish Hospital, Shahid-Beheshti University of Medical Sciences, Tehran, Iran
| | - Kamyar Moradi
- Neurology Department, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Bentolhoda Ziaadini
- Neurology Department, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Akram Panahi
- Neurology Department, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Shahriar Nafissi
- Neurology Department, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Bahram Haghi Ashtiani
- Neurology Department, Firouzgar Hospital, Iran University of Medical Sciences, Tehran, Iran
| | - Farzad Fatehi
- Neurology Department, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
14
|
Kesim-Sahin O, Sirin NG, Erbas B, Artug T, Oguz-Akarsu E, Kocasoy-Orhan E, Baslo MB, Mammadova N, Emekli U, Oge AE. Compound muscle action potential scan and MScanFit motor unit number estimation during Wallerian degeneration after nerve transections. Muscle Nerve 2020; 62:239-246. [PMID: 32415858 DOI: 10.1002/mus.26923] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2020] [Revised: 05/10/2020] [Accepted: 05/11/2020] [Indexed: 11/07/2022]
Abstract
BACKGROUND Compound muscle action potential (CMAP) scan and MScanFit have been used to understand the consequences of denervation and reinnervation. This study aimed to monitor these parameters during Wallerian degeneration (WD) after acute nerve transections (ANT). METHODS Beginning after urgent surgery, CMAP scans were recorded at 1-2 day intervals in 12 patients with ANT of the ulnar or median nerves, by stimulating the distal stump (DS). Stimulus intensities (SI), steps, returners, and MScanFit were calculated. Studies were grouped according to the examination time after ANT. Results were compared with those of 27 controls. RESULTS CMAP amplitudes and MScanFit progressively declined, revealing a positive correlation with one another. SIs were higher in WD groups than controls. Steps appeared or disappeared in follow-up scans. The late WD group had higher returner% than the early WD and control groups. CONCLUSIONS MScanFit can monitor neuromuscular dysfunction during WD. SIs revealed excitability changes in DS.
Collapse
Affiliation(s)
- Ozlem Kesim-Sahin
- Departments of Neurology and Clinical Neurophysiology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey
| | - Nermin Gorkem Sirin
- Departments of Neurology and Clinical Neurophysiology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey
| | - Bahar Erbas
- Departments of Neurology and Clinical Neurophysiology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey.,Department of Pharmacology, Istanbul Bilim University, Istanbul, Turkey
| | - Tugrul Artug
- Departments of Neurology and Clinical Neurophysiology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey.,Department of Electrical and Electronics Engineering, Istanbul Arel University, Istanbul, Turkey
| | - Emel Oguz-Akarsu
- Departments of Neurology and Clinical Neurophysiology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey
| | - Elif Kocasoy-Orhan
- Departments of Neurology and Clinical Neurophysiology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey
| | - Mehmet Baris Baslo
- Departments of Neurology and Clinical Neurophysiology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey
| | - Nermin Mammadova
- Department of Reconstructive and Plastic Surgery, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey
| | - Ufuk Emekli
- Department of Reconstructive and Plastic Surgery, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey
| | - Ali Emre Oge
- Departments of Neurology and Clinical Neurophysiology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey
| |
Collapse
|
15
|
Zong Y, Lu Z, Zhang L, Li X, Zhou P. Motor unit number of the first dorsal interosseous muscle estimated from CMAP scan with different pulse widths and steps. J Neural Eng 2020; 17:014001. [PMID: 31726441 DOI: 10.1088/1741-2552/ab57cc] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVE A compound muscle action potential (CMAP) scan has different settings such as stimulus frequency, duration (or pulse width), and the number of stimuli (or steps). This study aims to evaluate the influence of different stimulation protocols on MScanFit, a recently developed approach to motor unit number estimation (MUNE) from CMAP scan. APPROACH CMAP scans of the first dorsal interosseous (FDI) muscle were performed using four protocols with different pulse widths (0.1 ms, 0.2 ms) and steps (500, 1000) in twelve neurologically intact subjects. For each CMAP scan, the MUNE was derived using MScanFit. MAIN RESULTS Across all subjects, a significantly higher MUNE was obtained using stimulus pulse width of 0.1 ms (500 steps: 107. 7 ± 21.3; 1000 steps: 94.9 ± 22.07) than that using pulse width of 0.2 ms (500 steps: 81.8 ± 9.9; 1000 steps: 77.8 ± 16.1) (p < 0.001). However, no significant difference in MUNE was observed using 500 and 1000 steps (p > 0.1). No cross effect of pulse width and steps was found between four different protocols (p > 0.1). SIGNIFICANCE Given these results, a stimulation protocol of 0.1 ms pulse width and 500 steps is recommended for CMAP scan recording of the FDI muscle toward estimating motor unit number using MScanFit.
Collapse
Affiliation(s)
- Ya Zong
- Department of Physical Medicine and Rehabilitation, University of Texas Health Science Center at Houston, TIRR Memorial Hermann Research Center, Houston, TX, United States of America. Guangdong Work Injury Rehabilitation Center, Guangzhou, Guangdong, People's Republic of China. Department of Rehabilitation Sciences, School of Medicine, Ruijin Hospital, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | | | | | | | | |
Collapse
|
16
|
Sleutjes BTHM, Wijngaarde CA, Wadman RI, Otto LAM, Asselman FL, Cuppen I, van den Berg LH, van der Pol WL, Goedee HS. Assessment of motor unit loss in patients with spinal muscular atrophy. Clin Neurophysiol 2020; 131:1280-1286. [PMID: 32305855 DOI: 10.1016/j.clinph.2020.01.018] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2019] [Revised: 12/23/2019] [Accepted: 01/13/2020] [Indexed: 12/11/2022]
Abstract
OBJECTIVE To assess motor unit (MU) changes in patients with spinal muscular atrophy (SMA) using compound muscle action potential (CMAP) scans. METHODS We performed CMAP scan recordings in median nerves of 24 treatment-naïve patients (median age 39; range 12-75 years) with SMA types 2-4. From each scan, we determined maximum CMAP amplitude (CMAPmax), a motor unit number estimate (MUNE), and D50 which quantifies the largest discontinuities within CMAP scans. RESULTS Median CMAPmax was 8.1 mV (range 0.9-14.6 mV), MUNE was 29 (range 6-131), and D50 was 25 (range 2-57). We found a reduced D50 (<25) in patients with normal CMAPmax (n = 12), indicating MU loss and enlarged MUs due to reinnervation. Lower D50 values were associated with decreased MUNE (P < 0.001, r = 0.68, n = 43). CMAPmax, MUNE and D50 values differed between SMA types (P < 0.001). Lower motor function scores were related to patients with lower CMAPmax, MUNE and D50 values (P < 0.001). CONCLUSIONS The CMAP scan is an easily applicable technique that is superior to routine assessment of CMAPmax in SMA. SIGNIFICANCE The detection of pathological MU changes across the spectrum of SMA may provide important biomarkers for evaluating disease course and monitoring treatment efficacy.
Collapse
Affiliation(s)
- Boudewijn T H M Sleutjes
- Department of Neurology, UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, the Netherlands.
| | - Camiel A Wijngaarde
- Department of Neurology, UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Renske I Wadman
- Department of Neurology, UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Louise A M Otto
- Department of Neurology, UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Fay-Lynn Asselman
- Department of Neurology, UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Inge Cuppen
- Department of Neurology and Child Neurology, UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Leonard H van den Berg
- Department of Neurology, UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, the Netherlands
| | - W Ludo van der Pol
- Department of Neurology, UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, the Netherlands
| | - H Stephan Goedee
- Department of Neurology, UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, the Netherlands
| |
Collapse
|
17
|
Kristensen A, Bostock H, Finnerup N, Andersen H, Jensen T, Gylfadottir S, Itani M, Krøigård T, Sindrup S, Tankisi H. Detection of early motor involvement in diabetic polyneuropathy using a novel MUNE method – MScanFit MUNE. Clin Neurophysiol 2019; 130:1981-1987. [DOI: 10.1016/j.clinph.2019.08.003] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 07/05/2019] [Accepted: 08/12/2019] [Indexed: 12/13/2022]
|
18
|
Stålberg E, van Dijk H, Falck B, Kimura J, Neuwirth C, Pitt M, Podnar S, Rubin DI, Rutkove S, Sanders DB, Sonoo M, Tankisi H, Zwarts M. Standards for quantification of EMG and neurography. Clin Neurophysiol 2019; 130:1688-1729. [DOI: 10.1016/j.clinph.2019.05.008] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Revised: 05/07/2019] [Accepted: 05/09/2019] [Indexed: 12/11/2022]
|
19
|
Sirin NG, Oguz Akarsu E, Kocasoy Orhan E, Erbas B, Artug T, Dede HO, Baslo MB, Idrisoglu HA, Oge AE. Parameters derived from compound muscle action potential scan for discriminating amyotrophic lateral sclerosis‐related denervation. Muscle Nerve 2019; 60:400-408. [DOI: 10.1002/mus.26644] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Revised: 07/13/2019] [Accepted: 07/16/2019] [Indexed: 12/11/2022]
Affiliation(s)
- N. Gorkem Sirin
- Department of Neurology, Istanbul Faculty of MedicineIstanbul University Istanbul Turkey
| | - Emel Oguz Akarsu
- Department of Neurology, Istanbul Faculty of MedicineIstanbul University Istanbul Turkey
| | - Elif Kocasoy Orhan
- Department of Neurology, Istanbul Faculty of MedicineIstanbul University Istanbul Turkey
| | - Bahar Erbas
- Department of Neurology, Istanbul Faculty of MedicineIstanbul University Istanbul Turkey
| | - Tugrul Artug
- Electrical and Electronics EngineeringIstanbul Arel University Istanbul Turkey
| | - H. Ozlem Dede
- Department of Neurology, Istanbul Faculty of MedicineIstanbul University Istanbul Turkey
| | - M. Baris Baslo
- Department of Neurology, Istanbul Faculty of MedicineIstanbul University Istanbul Turkey
| | - Halil A. Idrisoglu
- Department of Neurology, Istanbul Faculty of MedicineIstanbul University Istanbul Turkey
| | - A. Emre Oge
- Department of Neurology, Istanbul Faculty of MedicineIstanbul University Istanbul Turkey
| |
Collapse
|
20
|
Kiernan MC, Bostock H, Park SB, Kaji R, Krarup C, Krishnan AV, Kuwabara S, Lin CSY, Misawa S, Moldovan M, Sung J, Vucic S, Wainger BJ, Waxman S, Burke D. Measurement of axonal excitability: Consensus guidelines. Clin Neurophysiol 2019; 131:308-323. [PMID: 31471200 DOI: 10.1016/j.clinph.2019.07.023] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 07/17/2019] [Accepted: 07/24/2019] [Indexed: 12/12/2022]
Abstract
Measurement of axonal excitability provides an in vivo indication of the properties of the nerve membrane and of the ion channels expressed on these axons. Axonal excitability techniques have been utilised to investigate the pathophysiological mechanisms underlying neurological diseases. This document presents guidelines derived for such studies, based on a consensus of international experts, and highlights the potential difficulties when interpreting abnormalities in diseased axons. The present manuscript provides a state-of-the-art review of the findings of axonal excitability studies and their interpretation, in addition to suggesting guidelines for the optimal performance of excitability studies.
Collapse
Affiliation(s)
- Matthew C Kiernan
- Brain and Mind Centre, University of Sydney and Institute of Clinical Neurosciences, Royal Prince Alfred Hospital, Sydney 2006, Australia.
| | - Hugh Bostock
- UCL Queen Square Institute of Neurology, London WC1N 3BG, United Kingdom
| | - Susanna B Park
- Brain and Mind Centre, University of Sydney and Institute of Clinical Neurosciences, Royal Prince Alfred Hospital, Sydney 2006, Australia
| | - Ryuji Kaji
- National Utano Hospital, 8-Narutaki Ondoyamacho, Ukyoku, Kyoto 616-8255, Japan
| | - Christian Krarup
- Department of Neuroscience, University of Copenhagen and Department of Clinical Neurophysiology, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark
| | - Arun V Krishnan
- Prince of Wales Clinical School, University of New South Wales, Sydney, Australia
| | - Satoshi Kuwabara
- Department of Neurology, Graduate School of Medicine, Chiba University, Japan
| | - Cindy Shin-Yi Lin
- Brain and Mind Centre, University of Sydney and Institute of Clinical Neurosciences, Royal Prince Alfred Hospital, Sydney 2006, Australia
| | - Sonoko Misawa
- Department of Neurology, Graduate School of Medicine, Chiba University, Japan
| | - Mihai Moldovan
- Department of Neuroscience, University of Copenhagen and Department of Clinical Neurophysiology, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark
| | - Jiaying Sung
- Taipei Medical University, Wanfang Hospital, Taipei, Taiwan
| | - Steve Vucic
- Department of Neurology, Westmead Hospital, Western Clinical School, University of Sydney, Australia
| | - Brian J Wainger
- Department of Neurology and Anesthesiology, Critical Care & Pain Medicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Stephen Waxman
- Department of Neurology, Yale Medical School, New Haven, CT 06510, USA; Neurorehabilitation Research Center, Veterans Affairs Hospital, West Haven, CT 06516, USA
| | - David Burke
- Brain and Mind Centre, University of Sydney and Institute of Clinical Neurosciences, Royal Prince Alfred Hospital, Sydney 2006, Australia
| |
Collapse
|
21
|
Kristensen R, Bostock H, Tan S, Witt A, Fuglsang-Frederiksen A, Qerama E, Andersen H, Tankisi H. MScanFit motor unit number estimation (MScan) and muscle velocity recovery cycle recordings in amyotrophic lateral sclerosis patients. Clin Neurophysiol 2019; 130:1280-1288. [DOI: 10.1016/j.clinph.2019.04.713] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2018] [Revised: 03/08/2019] [Accepted: 04/14/2019] [Indexed: 12/13/2022]
|
22
|
Garg N, Park SB, Howells J, Vucic S, Yiannikas C, Mathey EK, Nguyen T, Noto Y, Barnett MH, Krishnan AV, Spies J, Bostock H, Pollard JD, Kiernan MC. Conduction block in immune-mediated neuropathy: paranodopathy versus axonopathy. Eur J Neurol 2019; 26:1121-1129. [PMID: 30882969 DOI: 10.1111/ene.13953] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Accepted: 03/11/2019] [Indexed: 12/15/2022]
Abstract
BACKGROUND AND PURPOSE Conduction block is a pathognomonic feature of immune-mediated neuropathies. The aim of this study was to advance understanding of pathophysiology and conduction block in chronic inflammatory demyelinating polyneuropathy (CIDP) and multifocal motor neuropathy (MMN). METHODS A multimodal approach was used, incorporating clinical phenotyping, neurophysiology, immunohistochemistry and structural assessments. RESULTS Of 49 CIDP and 14 MMN patients, 25% and 79% had median nerve forearm block, respectively. Clinical scores were similar in CIDP patients with and without block. CIDP patients with median nerve block demonstrated markedly elevated thresholds and greater threshold changes in threshold electrotonus, whilst those without did not differ from healthy controls in electrotonus parameters. In contrast, MMN patients exhibited marked increases in superexcitability. Nerve size was similar in both CIDP groups at the site of axonal excitability. However, CIDP patients with block demonstrated more frequent paranodal serum binding to teased rat nerve fibres. In keeping with these findings, mathematical modelling of nerve excitability recordings in CIDP patients with block support the role of paranodal dysfunction and enhanced leakage of current between the node and internode. In contrast, changes in MMN probably resulted from a reduction in ion channel density along axons. CONCLUSIONS The underlying pathologies in CIDP and MMN are distinct. Conduction block in CIDP is associated with paranodal dysfunction which may be antibody-mediated in a subset of patients. In contrast, MMN is characterized by channel dysfunction downstream from the site of block.
Collapse
Affiliation(s)
- N Garg
- Brain and Mind Centre, Sydney Medical School, University of Sydney, Sydney, NSW, Australia.,Department of Neurology, Royal Prince Alfred Hospital, Sydney, NSW, Australia
| | - S B Park
- Brain and Mind Centre, Sydney Medical School, University of Sydney, Sydney, NSW, Australia
| | - J Howells
- Brain and Mind Centre, Sydney Medical School, University of Sydney, Sydney, NSW, Australia
| | - S Vucic
- Departments of Neurology and Neurophysiology, Westmead Hospital, University of Sydney, Sydney, NSW, Australia
| | - C Yiannikas
- Department of Neurology, Concord and Royal North Shore Hospitals, University of Sydney, Sydney, NSW, Australia
| | - E K Mathey
- Brain and Mind Centre, Sydney Medical School, University of Sydney, Sydney, NSW, Australia
| | - T Nguyen
- Brain and Mind Centre, Sydney Medical School, University of Sydney, Sydney, NSW, Australia
| | - Y Noto
- Brain and Mind Centre, Sydney Medical School, University of Sydney, Sydney, NSW, Australia
| | - M H Barnett
- Brain and Mind Centre, Sydney Medical School, University of Sydney, Sydney, NSW, Australia.,Department of Neurology, Royal Prince Alfred Hospital, Sydney, NSW, Australia
| | - A V Krishnan
- Prince of Wales Clinical School, University of New South Wales, Sydney, NSW, Australia
| | - J Spies
- Brain and Mind Centre, Sydney Medical School, University of Sydney, Sydney, NSW, Australia.,Department of Neurology, Royal Prince Alfred Hospital, Sydney, NSW, Australia
| | - H Bostock
- MRC Centre for Neuromuscular Diseases, National Hospital for Neurology and Neurosurgery, London, UK.,Institute of Neurology, University College London, London, UK
| | - J D Pollard
- Brain and Mind Centre, Sydney Medical School, University of Sydney, Sydney, NSW, Australia.,Department of Neurology, Royal Prince Alfred Hospital, Sydney, NSW, Australia
| | - M C Kiernan
- Brain and Mind Centre, Sydney Medical School, University of Sydney, Sydney, NSW, Australia.,Department of Neurology, Royal Prince Alfred Hospital, Sydney, NSW, Australia
| |
Collapse
|
23
|
Jacobsen AB, Bostock H, Tankisi H. Following disease progression in motor neuron disorders with 3 motor unit number estimation methods. Muscle Nerve 2018; 59:82-87. [DOI: 10.1002/mus.26304] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/15/2018] [Indexed: 02/02/2023]
Affiliation(s)
- Anna Bystrup Jacobsen
- Department of Clinical Neurophysiology; Aarhus University Hospital; Nørrebrogade 44, 8000 Aarhus C Denmark
| | - Hugh Bostock
- Institute of Neurology; University College London; London UK
| | - Hatice Tankisi
- Department of Clinical Neurophysiology; Aarhus University Hospital; Nørrebrogade 44, 8000 Aarhus C Denmark
| |
Collapse
|
24
|
Garg N, Park SB, Kiernan MC. Inflammatory neuropathies: all shapes and sizes. J Neurol Neurosurg Psychiatry 2018; 89:1128. [PMID: 29945878 DOI: 10.1136/jnnp-2018-318513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2018] [Accepted: 05/26/2018] [Indexed: 11/04/2022]
Affiliation(s)
- Nidhi Garg
- Brain and Mind Centre, Sydney Medical School, The University of Sydney, Sydney, New South Wales, Australia .,Institute of Clinical Neurosciences, Royal Prince Alfred Hospital, Sydney, New South Waes, Australia
| | - Susanna B Park
- Brain and Mind Centre, Sydney Medical School, The University of Sydney, Sydney, New South Wales, Australia
| | - Matthew C Kiernan
- Brain and Mind Centre, Sydney Medical School, The University of Sydney, Sydney, New South Wales, Australia.,Institute of Clinical Neurosciences, Royal Prince Alfred Hospital, Sydney, New South Waes, Australia
| |
Collapse
|
25
|
Abstract
Since the discovery of an acute monophasic paralysis, later coined Guillain-Barré syndrome, almost 100 years ago, and the discovery of chronic, steroid-responsive polyneuropathy 50 years ago, the spectrum of immune-mediated polyneuropathies has broadened, with various subtypes continuing to be identified, including chronic inflammatory demyelinating polyradiculoneuropathy (CIDP) and multifocal motor neuropathy (MMN). In general, these disorders are speculated to be caused by autoimmunity to proteins located at the node of Ranvier or components of myelin of peripheral nerves, although disease-associated autoantibodies have not been identified for all disorders. Owing to the numerous subtypes of the immune-mediated neuropathies, making the right diagnosis in daily clinical practice is complicated. Moreover, treating these disorders, particularly their chronic variants, such as CIDP and MMN, poses a challenge. In general, management of these disorders includes immunotherapies, such as corticosteroids, intravenous immunoglobulin or plasma exchange. Improvements in clinical criteria and the emergence of more disease-specific immunotherapies should broaden the therapeutic options for these disabling diseases.
Collapse
|
26
|
de Carvalho M, Barkhaus PE, Nandedkar SD, Swash M. Motor unit number estimation (MUNE): Where are we now? Clin Neurophysiol 2018; 129:1507-1516. [DOI: 10.1016/j.clinph.2018.04.748] [Citation(s) in RCA: 78] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Revised: 03/31/2018] [Accepted: 04/29/2018] [Indexed: 12/13/2022]
|
27
|
The utility of motor unit number estimation methods versus quantitative motor unit potential analysis in diagnosis of ALS. Clin Neurophysiol 2018; 129:646-653. [DOI: 10.1016/j.clinph.2018.01.002] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2017] [Revised: 11/30/2017] [Accepted: 01/03/2018] [Indexed: 12/12/2022]
|