Nguyen TK, Jun H, Louis JM, Mazigo E, Lee WJ, Youm HC, Shin J, Lungu DK, Kanyemba C, Ahmed MA, Muh F, Lee SJ, Na S, Chun W, Park WS, No JH, Kim MJ, Han ET, Han JH. Enhancing malaria detection in resource-limited areas: A high-performance colorimetric LAMP assay for Plasmodium falciparum screening. PLoS One 2024; 19:e0298087. [PMID: 38335219 PMCID: PMC10857711 DOI: 10.1371/journal.pone.0298087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 01/17/2024] [Indexed: 02/12/2024] Open
Abstract
Malaria eradication efforts in resource-limited areas require a rapid, economical, and accurate tool for detecting of the low parasitemia. The malaria rapid diagnostic test (mRDT) is the most suitable for on-site detection of the deadliest form of malaria, Plasmodium falciparum. However, the deletions of histidine rich protein 2 and 3 genes are known to compromise the effectiveness of mRDT. One of the approaches that have been explored intensively for on-site diagnostics is the loop-mediated isothermal amplification (LAMP). LAMP is a one-step amplification that allows the detection of Plasmodium species in less than an hour. Thus, this study aims to present a new primer set to enhance the performance of a colorimetric LAMP (cLAMP) for field application. The primer binding regions were selected within the A-type of P. falciparum 18S rRNA genes, which presents a dual gene locus in the genome. The test result of the newly designed primer indicates that the optimal reaction condition for cLAMP was 30 minutes incubation at 65°C, a shorter incubation time compared to previous LAMP detection methods that typically takes 45 to 60 minutes. The limit of detection (LoD) for the cLAMP using our designed primers and laboratory-grown P. falciparum (3D7) was estimated to be 0.21 parasites/μL which was 1,000-fold higher than referencing primers. Under optimal reaction condition, the new primer sets showed the sensitivity (100%, 95% CI: 80.49-100%) and specificity (100%, 95% CI: 94.64-100%) with 100% (95% CI: 95.70-100%) accuracy on the detection of dried blood spots from Malawi (n = 84). Briefly, the newly designed primer set for P. falciparum detection exhibited high sensitivity and specificity compared to referenced primers. One great advantage of this tool is its ability to be detected by the naked eye, enhancing field approaches. Thus, this tool has the potential to be effective for accurate early parasite detection in resource-limited endemic areas.
Collapse
Affiliation(s)
- Tuyet Kha Nguyen
- Department of Medical Environmental Biology and Tropical Medicine, School of Medicine, Kangwon National University, Chuncheon, Gangwon-do, Republic of Korea
| | - Hojong Jun
- Department of Medical Environmental Biology and Tropical Medicine, School of Medicine, Kangwon National University, Chuncheon, Gangwon-do, Republic of Korea
| | - Johnsy Mary Louis
- Department of Medical Environmental Biology and Tropical Medicine, School of Medicine, Kangwon National University, Chuncheon, Gangwon-do, Republic of Korea
| | - Ernest Mazigo
- Department of Medical Environmental Biology and Tropical Medicine, School of Medicine, Kangwon National University, Chuncheon, Gangwon-do, Republic of Korea
| | - Wang-Jong Lee
- Department of Medical Environmental Biology and Tropical Medicine, School of Medicine, Kangwon National University, Chuncheon, Gangwon-do, Republic of Korea
| | | | - Jieun Shin
- Noul Co., Ltd., Yongin, Gyeonggi-do, Republic of Korea
| | | | | | - Md Atique Ahmed
- ICMR-Regional Medical Research Centre, NER, Dibrugarh, Assam, India
| | - Fauzi Muh
- Faculty of Public Health, Department of Epidemiology and Tropical Diseases, Universitas Diponegoro, Semarang, Indonesia
| | - Se Jin Lee
- Department of Obstetrics and Gynecology, Kangwon National University Hospital, Chuncheon, Gangwon-do, Republic of Korea
| | - Sunghun Na
- Department of Obstetrics and Gynecology, Kangwon National University Hospital, Chuncheon, Gangwon-do, Republic of Korea
| | - Wanjoo Chun
- Department of Pharmacology, School of Medicine, Kangwon National University, Chuncheon, Gangwon-do, Republic of Korea
| | - Won Sun Park
- Department of Physiology, School of Medicine, Kangwon National University, Chuncheon, Gangwon-do, Republic of Korea
| | - Joo Hwan No
- Host-Parasite Research Laboratory, Institut Pasteur Korea, Seongnam, Gyeonggi-do, Republic of Korea
| | - Min-Jae Kim
- Department of Infectious Diseases, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Eun-Taek Han
- Department of Medical Environmental Biology and Tropical Medicine, School of Medicine, Kangwon National University, Chuncheon, Gangwon-do, Republic of Korea
| | - Jin-Hee Han
- Department of Medical Environmental Biology and Tropical Medicine, School of Medicine, Kangwon National University, Chuncheon, Gangwon-do, Republic of Korea
| |
Collapse
|
2
|
Calderaro A, Piccolo G, Chezzi C. The Laboratory Diagnosis of Malaria: A Focus on the Diagnostic Assays in Non-Endemic Areas. Int J Mol Sci 2024; 25:695. [PMID: 38255768 PMCID: PMC10815132 DOI: 10.3390/ijms25020695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 12/26/2023] [Accepted: 01/03/2024] [Indexed: 01/24/2024] Open
Abstract
Even if malaria is rare in Europe, it is a medical emergency and programs for its control should ensure both an early diagnosis and a prompt treatment within 24-48 h from the onset of the symptoms. The increasing number of imported malaria cases as well as the risk of the reintroduction of autochthonous cases encouraged laboratories in non-endemic countries to adopt diagnostic methods/algorithms. Microscopy remains the gold standard, but with limitations. Rapid diagnostic tests have greatly expanded the ability to diagnose malaria for rapid results due to simplicity and low cost, but they lack sensitivity and specificity. PCR-based assays provide more relevant information but need well-trained technicians. As reported in the World Health Organization Global Technical Strategy for Malaria 2016-2030, the development of point-of-care testing is important for the improvement of diagnosis with beneficial consequences for prompt/accurate treatment and for preventing the spread of the disease. Despite their limitations, diagnostic methods contribute to the decline of malaria mortality. Recently, evidence suggested that artificial intelligence could be utilized for assisting pathologists in malaria diagnosis.
Collapse
Affiliation(s)
- Adriana Calderaro
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (G.P.); (C.C.)
| | | | | |
Collapse
|
3
|
Ivarsson AC, Fransén E, Broumou I, Färnert A, Persson KEM, Söbirk SK. Head-to-head comparison of two loop-mediated isothermal amplification (LAMP) kits for diagnosis of malaria in a non-endemic setting. Malar J 2023; 22:377. [PMID: 38093251 PMCID: PMC10717323 DOI: 10.1186/s12936-023-04809-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 11/28/2023] [Indexed: 12/17/2023] Open
Abstract
BACKGROUND Light microscopy and rapid diagnostic tests (RDT) have long been the recommended diagnostic methods for malaria. However, in recent years, loop-mediated isothermal amplification (LAMP) techniques have been shown to offer superior performance, in particular concerning low-grade parasitaemia, by delivering higher sensitivity and specificity with low laboratory capacity requirements in little more than an hour. In this study, the diagnostic performance of two LAMP kits were assessed head-to-head, compared to highly sensitive quantitative real time PCR (qPCR), in a non-endemic setting. METHODS In this retrospective validation study two LAMP kits; Alethia® Illumigene Malaria kit and HumaTurb Loopamp™ Malaria Pan Detection (PDT) kit, were evaluated head-to-head for detection of Plasmodium-DNA in 133 biobanked blood samples from suspected malaria cases at the Clinical Microbiology Laboratory of Region Skåne, Sweden to determine their diagnostic performance compared to qPCR. RESULTS Of the 133 samples tested, qPCR detected Plasmodium DNA in 41 samples (defined as true positives), and the two LAMP methods detected 41 and 37 of those, respectively. The results from the HumaTurb Loopamp™ Malaria PDT kit were in complete congruence with the qPCR, with a sensitivity of 100% (95% CI 91.40-100%) and specificity of 100% (95% CI 96.07-100%). The Alethia® Illumigene Malaria kit had a sensitivity of 90.24% (95% CI 76.87-97.28) and a specificity of 95.65% (95% CI 89.24-98.80) as compared to qPCR. CONCLUSIONS This head-to-head comparison showed higher performance indicators of the HumaTurb Loopamp™ Malaria PDT kit compared to the Alethia® illumigene Malaria kit for detection of malaria.
Collapse
Affiliation(s)
- Anna-Clara Ivarsson
- Clinical Microbiology, Infection Prevention and Control, Office for Medical Services, Region Skåne, Lund, Sweden.
| | - Elin Fransén
- Clinical Microbiology, Infection Prevention and Control, Office for Medical Services, Region Skåne, Lund, Sweden
| | - Ioanna Broumou
- Department of Medicine Solna, Karolinska Institute, Stockholm, Sweden
- Centre for Molecular Medicine, Stockholm, Sweden
| | - Anna Färnert
- Department of Medicine Solna, Karolinska Institute, Stockholm, Sweden
- Centre for Molecular Medicine, Stockholm, Sweden
- Department of Infectious Diseases, Karolinska University Hospital, Stockholm, Sweden
| | - Kristina E M Persson
- Division of Clinical Chemistry and Pharmacology, Department of Laboratory Medicine, Lund University, Lund, Sweden
- Clinical Chemistry and Pharmacology, Laboratory Medicine, Office for Medical Services, Region Skåne, Lund, Sweden
| | - Sara Karlsson Söbirk
- Clinical Microbiology, Infection Prevention and Control, Office for Medical Services, Region Skåne, Lund, Sweden
- Division of Infection Medicine, Department of Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
4
|
Boonchuay K, Thomrongsuwannakij T, Chagas CRF, Pornpanom P. Prevalence and Diversity of Blood Parasites ( Plasmodium, Leucocytozoon and Trypanosoma) in Backyard Chickens ( Gallus gallus domesticus) Raised in Southern Thailand. Animals (Basel) 2023; 13:2798. [PMID: 37685062 PMCID: PMC10486576 DOI: 10.3390/ani13172798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 08/29/2023] [Accepted: 09/01/2023] [Indexed: 09/10/2023] Open
Abstract
Avian malaria and leucocytozoonosis can cause fatal diseases, whereas avian trypanosomiasis is reported to be harmless in chickens. Backyard chickens can be infected by several pathogens, including blood parasites, that may shed to industrial poultry production, with a consequently higher economic impact. This study aimed to investigate the presence of several blood parasites (Plasmodium, Leucocytozoon and Trypanosoma) in backyard chickens raised in Southern Thailand, using PCR-based detection and microscopic methods. From June 2021 to June 2022, 57 backyard chickens were sampled. Fresh thin blood smears were prepared from 11 individuals, and buffy coat smears were prepared from 55 of them. Both thin blood smears and buffy coat smears were used for microscopic analysis. Two nested PCR protocols that amplify a fragment of cytochrome b (cytb) and small subunit rRNA (SSU rRNA) genes were used to identify Haemosporida and Trypanosoma parasites, respectively. The number of positive samples was higher with the application of nested PCR than when buffy coat smears were used. Three new Plasmodium lineages (GALLUS47-49) and thirteen Leucocytozoon lineages (GALLUS50-62) were found. Trophozoites, meronts and gametocytes of Plasmodium gallinaceum (GALLUS01) were present in one thin blood smear. All thin blood smears revealed Leucocytozoon infections, but only three samples were a single infection. These three samples revealed the presence of fusiform host cell-parasite complexes, of which the morphological features resembled those of Leucocytozoon macleani (possible synonym is Leucocytozoon sabrazesi), while the cytb showed that this parasite is closely related to the lineage GALLUS06-07, described as Leucocytozoon schouteni. The Trypanosoma prevalence was 33.33%; it was present in only one of the thin blood smears, and it resembles Trypanosoma calmettei. This study showed the prevalence of a high diversity of Plasmodium (64.91%) and Leucocytozoon (89.47%) in Thai chickens. Both nested-PCR and buffy coat smear can be used as the diagnostic tool for the testing of Plasmodium, Leucocytozoon and Trypanosoma for parasitic control in backyard chickens and poultry farms. The information on the parasite species that can be found in chickens raised in Southern Thailand was also considered as the baseline information for further study.
Collapse
Affiliation(s)
- Kanpapat Boonchuay
- Akkhraratchakumari Veterinary College, Walailak University, Nakhon Si Thammarat 80160, Thailand; (K.B.); (T.T.)
| | | | | | - Pornchai Pornpanom
- Akkhraratchakumari Veterinary College, Walailak University, Nakhon Si Thammarat 80160, Thailand; (K.B.); (T.T.)
- Informatics Innovation Center of Excellence, Walailak University, Nakhon Si Thammarat 80160, Thailand
- One Health Research Center, Walailak University, Nakhon Si Thammarat 80160, Thailand
| |
Collapse
|
5
|
van Bergen KJM, Stuitje AR, Akkers RC, Vermeer HJ, Castel R, Mank TG. Performance of a novel melting curve-based qPCR assay for malaria parasites in routine clinical practice in non-endemic setting. Malar J 2023; 22:191. [PMID: 37349789 DOI: 10.1186/s12936-023-04617-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Accepted: 06/06/2023] [Indexed: 06/24/2023] Open
Abstract
BACKGROUND High-quality malaria diagnosis is essential for effective treatment and clinical disease management. Microscopy and rapid diagnostic tests are the conventional methods performed as first-line malaria diagnostics in non-endemic countries. However, these methods lack the characteristic to detect very low parasitaemia, and accurate identification of the Plasmodium species can be difficult. This study evaluated the performance of the MC004 melting curve-based qPCR for the diagnosis of malaria in routine clinical practice in non-endemic setting. METHODS AND RESULTS Whole blood samples were collected from 304 patients with clinical suspicion of malaria and analysed by both the MC004 assay and conventional diagnostics. Two discrepancies were found between the MC004 assay and microscopy. Repeated microscopic analysis confirmed the qPCR results. Comparison of the parasitaemia of nineteen Plasmodium falciparum samples determined by both microscopy and qPCR showed the potential of the MC004 assay to estimate the parasite load of P. falciparum. Eight Plasmodium infected patients were followed after anti-malarial treatment by the MC004 assay and microscopy. The MC004 assay still detected Plasmodium DNA although no parasites were seen with microscopy in post-treatment samples. The rapid decline in Plasmodium DNA showed the potential for therapy-monitoring. CONCLUSION Implementation of the MC004 assay in non-endemic clinical setting improved the diagnosis of malaria. The MC004 assay demonstrated superior Plasmodium species identification, the ability to indicate the Plasmodium parasite load, and can potentially detect submicroscopic Plasmodium infections.
Collapse
Affiliation(s)
- Kim J M van Bergen
- Result Laboratorium, Albert Schweitzer Hospital, Albert Schweitzerplaats 25, 3300 AK, Dordrecht, The Netherlands.
| | - Antoine R Stuitje
- MRC Holland, Willem Schoutenstraat 1, 1057 DL, Amsterdam, The Netherlands
| | - Robert C Akkers
- Result Laboratorium, Albert Schweitzer Hospital, Albert Schweitzerplaats 25, 3300 AK, Dordrecht, The Netherlands
| | - Henricus J Vermeer
- Result Laboratorium, Albert Schweitzer Hospital, Albert Schweitzerplaats 25, 3300 AK, Dordrecht, The Netherlands
| | - Rob Castel
- Result Laboratorium, Albert Schweitzer Hospital, Albert Schweitzerplaats 25, 3300 AK, Dordrecht, The Netherlands
| | - Theo G Mank
- Regional Laboratory for Medical Microbiology and Public Health, Boerhaavelaan 26, 2035 RC, Haarlem, The Netherlands
| |
Collapse
|
6
|
Boualam MA, Heitzmann A, Mousset F, Aboudharam G, Drancourt M, Pradines B. Use of rapid diagnostic tests for the detection of ancient malaria infections in dental pulp from the sixth century in Versailles, France. Malar J 2023; 22:151. [PMID: 37161537 PMCID: PMC10169320 DOI: 10.1186/s12936-023-04582-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Accepted: 05/03/2023] [Indexed: 05/11/2023] Open
Abstract
BACKGROUND Paleomicrobiological data have clarified that Plasmodium spp. was circulating in the past in southern European populations, which are now devoid of malaria. The aim of this study was to evaluate the efficacy of immunodetection and, more particularly, rapid diagnostic tests (RDT), in order to further assess Plasmodium infections in ancient northern European populations. METHODS A commercially available RDT, PALUTOP® + 4 OPTIMA, which is routinely used to detect malaria, was used to detect Plasmodium antigens from proteins recovered from ancient specimens extracted from 39 dental pulp samples. These samples were collected from 39 individuals who were buried in the sixth century, near the site of the current Palace of Versailles in France. Positive and negative controls were also used. Antigens detected were quantified using chemiluminescence imaging system analysis. RESULTS Plasmodium antigens were detected in 14/39 (35.9%) individuals, including Plasmodium vivax antigens in 11 individuals and Plasmodium falciparum antigens co-detected in two individuals, while Pan-Plasmodium antigens were detected in three individuals. Controls all yielded expected results. CONCLUSIONS The data reported here showed that RDTs are a suitable tool for detecting Plasmodium spp. antigens in ancient dental pulp samples, and demonstrated the existence of malaria in Versailles, France, in the sixth century. Plasmodium vivax, which is regarded as being responsible for an attenuated form of malaria and less deadly forms, was the most prevalent species. This illustrates, for the first time in ancient populations, co-infection with P. falciparum, bringing into question the climate-driven ecosystems prevailing at that time in the Versailles area.
Collapse
Affiliation(s)
- Mahmoud A Boualam
- IHU Méditerranée Infection, 19-21 Bd Jean Moulin, 13005, Marseille, France
- Aix-Marseille Univ, IRD, MEPHI, AP-HM, 19-21 Bd Jean Moulin, 13005, Marseille, France
| | - Annick Heitzmann
- Direction du Patrimoine et des Jardins, Château de Versailles, Place d'Armes, 78008, Versailles, France
| | - Florence Mousset
- Direction régionale des affaires culturelles d'Île-de-France, Service Régional de l'archéologie, 311 Rue Le Peletier, 75009, Paris, France
| | - Gérard Aboudharam
- IHU Méditerranée Infection, 19-21 Bd Jean Moulin, 13005, Marseille, France
- Aix-Marseille Univ, IRD, MEPHI, AP-HM, 19-21 Bd Jean Moulin, 13005, Marseille, France
- Ecole de Médecine Dentaire, Aix-Marseille Univ, Bd Jean Moulin, 13005, Marseille, France
| | - Michel Drancourt
- IHU Méditerranée Infection, 19-21 Bd Jean Moulin, 13005, Marseille, France
- Aix-Marseille Univ, IRD, MEPHI, AP-HM, 19-21 Bd Jean Moulin, 13005, Marseille, France
| | - Bruno Pradines
- IHU Méditerranée Infection, 19-21 Bd Jean Moulin, 13005, Marseille, France.
- Unité parasitologie et entomologie, Département microbiologie et maladies infectieuses, Institut de recherche biomédicale des armées, 19-21 Bd Jean Moulin, 13005, Marseille, France.
- Aix-Marseille Univ, IRD, SSA, AP-HM, VITROME, 19-21 Bd Jean Moulin, 13005, Marseille, France.
- Centre national de référence du paludisme, 19-21 Bd Jean Moulin, 13005, Marseille, France.
| |
Collapse
|
7
|
Mwangonela ZE, Ye Y, Rachel Q, Msuya HM, Mwamlima TG, Mswata SS, Chaki PP, Kimaro EG, Mweya CN, Mpina MG, Mwangoka GW. Field evaluation of the novel One Step Malaria Pf and Pf/Pv rapid diagnostic tests and the proportion of HRP-2 gene deletion identified on samples collected in the Pwani region, Tanzania. BULLETIN OF THE NATIONAL RESEARCH CENTRE 2023; 47:17. [PMID: 36776799 PMCID: PMC9904258 DOI: 10.1186/s42269-023-00992-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 01/29/2023] [Indexed: 06/18/2023]
Abstract
Background Malaria rapid diagnostic tests (mRDTs) have played an important role in the early detection of clinical malaria in an endemic area. While several mRDTs are currently on the market, the availability of mRDTs with high sensitivity and specificity will merit the fight against malaria. We evaluated the field performance of a novel One Step Malaria (P.f/P.v) Tri-line and One Step Malaria (P.f) rapid test kits in Pwani, Tanzania. Methods In a cross-sectional study conducted in Bagamoyo and Kibiti districts in Tanzania, symptomatic patients were tested using the SD BIOLINE, One Step Malaria (P.f/P.v) Tri-line and One Step Malaria (P.f) rapid test kits, microscope, and quantitative Polymerase Chain Reaction (qPCR). An additional qPCR assay was carried out to detect Histidine-Rich Protein 2 (HRP-2) gene deletion on mRDT negative but microscope and qPCR positive samples. Microscope results confirmed by qPCR were used for analysis, where qPCR was used as a reference method. Results The sensitivity and specificity of One Step P.f/P.v Tri-line mRDTs were 96.0% (CI 93.5-97.7%) and 98.3% (CI 96.8-99.2%), respectively. One Step P.f mRDT had sensitivity and specificity of 95.2% (CI 92.5-97.1%) and 97.9% (CI 96.3-99.0%) respectively. Positive predictive value (PPV) was 97.6% (CI 95.4-98.7%) and negative predictive value (NPV) was 96.2% (CI 95.5-98.3%) for the One Step P.f/P.v Tri-line mRDTs respectively, while One Step P.f mRDT had positive predictive value (PPV) and negative predictive value (NPV) of 97.0% (CI 94.8-98.3%) and 96.7 (CI 94.9-97.9%) respectively. 9.8% (CI 7.84-11.76) of all samples tested and reported to be malaria-negative by mRDT had HRP-2 gene deletion. Conclusion One Step Malaria P.f/P.v Tri-line and One Step Malaria P.f rapid test kits have similar sensitivity and specificity as the standard mRDT that is currently in the market, demonstrating the potential to contribute in the fight against malaria in endemic settings. However, the identified malaria parasites population with HRP-2 gene deletion pose a threat to the current mRDT usability in the field and warrants further investigations.
Collapse
Affiliation(s)
- Zena E. Mwangonela
- Ifakara Health Institute Bagamoyo Branch, P.O.Box 74, Bagamoyo, Tanzania
- The Nelson Mandela African Institution of Science and Technology, P.O.Box 447, Arusha, Tanzania
| | - Young Ye
- InTec Products, Inc., 332 Xinguang Road Xinyang Industrial Area, Haicang, Xiamen City, 361022 China
| | - Qin Rachel
- InTec Products, Inc., 332 Xinguang Road Xinyang Industrial Area, Haicang, Xiamen City, 361022 China
| | - Hajirani M. Msuya
- Ifakara Health Institute Bagamoyo Branch, P.O.Box 74, Bagamoyo, Tanzania
| | - Tunu G. Mwamlima
- Ifakara Health Institute Bagamoyo Branch, P.O.Box 74, Bagamoyo, Tanzania
- The Nelson Mandela African Institution of Science and Technology, P.O.Box 447, Arusha, Tanzania
| | - Sarah S. Mswata
- Ifakara Health Institute Bagamoyo Branch, P.O.Box 74, Bagamoyo, Tanzania
| | - Prosper P. Chaki
- Ifakara Health Institute Bagamoyo Branch, P.O.Box 74, Bagamoyo, Tanzania
| | - Ester G. Kimaro
- The Nelson Mandela African Institution of Science and Technology, P.O.Box 447, Arusha, Tanzania
| | - Clement N. Mweya
- Univesity of Dar Es Salaam, Mbeya College of Health and Allied Science, P.O.Box 608, Mbeya, Tanzania
| | | | - Grace W. Mwangoka
- Ifakara Health Institute Bagamoyo Branch, P.O.Box 74, Bagamoyo, Tanzania
| |
Collapse
|
8
|
Hemachandran K, Alasiry A, Marzougui M, Ganie SM, Pise AA, Alouane MTH, Chola C. Performance Analysis of Deep Learning Algorithms in Diagnosis of Malaria Disease. Diagnostics (Basel) 2023; 13:diagnostics13030534. [PMID: 36766640 PMCID: PMC9914762 DOI: 10.3390/diagnostics13030534] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Revised: 01/07/2023] [Accepted: 01/20/2023] [Indexed: 02/04/2023] Open
Abstract
Malaria is predominant in many subtropical nations with little health-monitoring infrastructure. To forecast malaria and condense the disease's impact on the population, time series prediction models are necessary. The conventional technique of detecting malaria disease is for certified technicians to examine blood smears visually for parasite-infected RBC (red blood cells) underneath a microscope. This procedure is ineffective, and the diagnosis depends on the individual performing the test and his/her experience. Automatic image identification systems based on machine learning have previously been used to diagnose malaria blood smears. However, so far, the practical performance has been insufficient. In this paper, we have made a performance analysis of deep learning algorithms in the diagnosis of malaria disease. We have used Neural Network models like CNN, MobileNetV2, and ResNet50 to perform this analysis. The dataset was extracted from the National Institutes of Health (NIH) website and consisted of 27,558 photos, including 13,780 parasitized cell images and 13,778 uninfected cell images. In conclusion, the MobileNetV2 model outperformed by achieving an accuracy rate of 97.06% for better disease detection. Also, other metrics like training and testing loss, precision, recall, fi-score, and ROC curve were calculated to validate the considered models.
Collapse
Affiliation(s)
- K. Hemachandran
- Department of Analytics, School of Business, Woxsen University, Hyderabad 502345, Telangana, India
| | - Areej Alasiry
- College of Computer Science, King Khalid University, Abha 62529, Saudi Arabia
| | - Mehrez Marzougui
- College of Computer Science, King Khalid University, Abha 62529, Saudi Arabia
| | - Shahid Mohammad Ganie
- Department of Analytics, School of Business, Woxsen University, Hyderabad 502345, Telangana, India
| | - Anil Audumbar Pise
- Siatik Premier Google Cloud Platform Partner, Johannesburg 2000, South Africa
- School of Computer Science and Applied Mathematics, University of the Witwatersrand, Johannesburg 2000, South Africa
- School Saveetha School of Engineering, Chennai 600124, Tamil Nadu, India
| | - M. Turki-Hadj Alouane
- College of Computer Science, King Khalid University, Abha 62529, Saudi Arabia
- Correspondence:
| | - Channabasava Chola
- Department of Studies in Computer Science, University of Mysore, Manasagangothri, Mysore 570006, Karnataka, India
| |
Collapse
|
9
|
Assessment of a Commercial Real-Time PCR Assay (Vitassay qPCR Malaria 5 Test) to Detect Human Malaria Infection in Travelers Returning to France. Diagnostics (Basel) 2022; 12:diagnostics12112747. [DOI: 10.3390/diagnostics12112747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Revised: 11/03/2022] [Accepted: 11/07/2022] [Indexed: 11/12/2022] Open
Abstract
Malaria is the most common human parasitic disease in the world with the highest morbidity and mortality. Due to the severity of malaria caused by Plasmodium falciparum and the urgency of therapeutic management, quick and reliable diagnosis is required for early detection. Blood smear microscopy remains the gold standard for malaria diagnosis. Molecular diagnosis techniques are the most sensitive and specific in cases of low parasitaemia and in the detection of mixed infections. The purpose of this study was to evaluate a new commercial test involving the molecular diagnostic technique to detect the five human Plasmodium species. The Vitassay qPCR Malaria 5 test is based on the multiplex real-time PCR of a conserved target region of the 18S rRNA gene for the five human Plasmodium species. A total of 190 samples collected from imported cases of malaria were diagnosed using this test and compared against a homemade reference real-time PCR. The sensitivities of the Vitassay qPCR Malaria 5 test for all Plasmodium species ranged from 93.8% to 100% and specificity ranged from 97.7% to 100%. Based on these criteria, this test is recommended for the diagnosis of the human Plasmodium species.
Collapse
|
10
|
Zhang J, Chen X, Pan M, Qin Y, Zhao H, Yang Q, Li X, Zeng W, Xiang Z, Wu Y, Duan M, Li X, Wang X, Mazier D, Zhang Y, Zhu W, Sun K, Wu Y, Cui L, Huang Y, Yang Z. Application of a low-cost, specific, and sensitive loop-mediated isothermal amplification (LAMP) assay to detect Plasmodium falciparum imported from Africa. Mol Biochem Parasitol 2022; 252:111529. [PMID: 36374724 PMCID: PMC9890345 DOI: 10.1016/j.molbiopara.2022.111529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 08/12/2022] [Accepted: 10/26/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND Chinese citizens traveling abroad bring back imported malaria cases to China. Current malaria diagnostic tests, including microscopy and antigen-detecting rapid tests, cannot reliably detect low-density infections. To complement existing diagnostic methods, we aimed to develop a new loop-mediated isothermal amplification (LAMP) assay to detect and identify Plasmodium falciparum in Chinese travelers returning from Africa. METHODS We developed a miniaturized LAMP assay to amplify the actin I gene of P. falciparum. Each reaction consumed only 25% of the reagents used in a conventional LAMP assay and the same amount of DNA templates used in nested PCR. We evaluated this LAMP assay's performance and compared it to microscopy and a nested PCR assay using 466 suspected malaria cases imported from Africa. We assessed the sensitivity of the new LAMP assay using cultured P. falciparum, clinical samples, and a plasmid construct, allowing unprecedented precision when quantifying the limit of detection. RESULTS The new LAMP assay was highly sensitive and detected two more malaria cases than nested PCR. Compared to nested PCR, the sensitivity and specificity of the novel LAMP assay were 100% [95% confidence interval (CI) 98.5-100%] and 99.1% (95% CI 96.7-99.9%), respectively. When evaluated using serial dilutions of the plasmid construct, the detection limit of the new LAMP was as low as 102 copies/μL, 10-fold lower than PCR. The LAMP assay detected 0.01 parasites/μL of blood (equal to 0.04 parasites/μL of DNA) using cultured P. falciparum and 1-7 parasites/μL of blood (4-28 parasites/μL of DNA) in clinical samples, which is as good as or better than previously reported and commercially licensed assays. CONCLUSION The novel LAMP assay based on the P. falciparum actin I gene was specific, sensitive, and cost-effective, as it consumes 1/4 of the reagents in a typical LAMP reaction.
Collapse
Affiliation(s)
- Jiaqi Zhang
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China,Zhejiang Provincial Center for Disease Control and Prevention, No.3399 BinSheng Road, Binjiang District, Hangzhou, Zhejiang Province, 310051, China
| | - Xi Chen
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China
| | - Maohua Pan
- Shanglin County People’s Hospital, Shanglin, Guangxi, 530500, China
| | - Yucheng Qin
- Shanglin County People’s Hospital, Shanglin, Guangxi, 530500, China
| | - Hui Zhao
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China
| | - Qi Yang
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China
| | - Xinxin Li
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China
| | - Weilin Zeng
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China
| | - Zheng Xiang
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China
| | - Yanrui Wu
- Department of Cell Biology & Genetics, Kunming Medical University, Kunming, Yunnan,China
| | - Mengxi Duan
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China
| | - Xiaosong Li
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China
| | - Xun Wang
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China
| | - Dominique Mazier
- Sorbonne Université, INSERM, CNRS, Centre d’Immunologie et des Maladies Infectieuses, CIMI, Paris, France
| | - Yanmei Zhang
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China
| | - Wenya Zhu
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China
| | - Kemin Sun
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China
| | - Yiman Wu
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China
| | - Liwang Cui
- Department of Internal Medicine, Morsani College of Medicine, University of South Florida, 3720 Spectrum Boulevard, Suite 304, MDC84, Tampa, FL 33612, USA
| | - Yaming Huang
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China,Guangxi Zhuang Autonomous Region Center for Disease Prevention and Control, Nanning, Guangxi, 530021, China,Correspondence:
| | - Zhaoqing Yang
- Department of Pathogen Biology and Immunology, Kunming Medical University, Kunming, Yunnan, 650500, China,Correspondence:
| |
Collapse
|
11
|
Ansah F, Krampa F, Donkor JK, Owusu-Appiah C, Ashitei S, Kornu VE, Danku RK, Chirawurah JD, Awandare GA, Aniweh Y, Kanyong P. Ultrasensitive electrochemical genosensors for species-specific diagnosis of malaria. Electrochim Acta 2022; 429:140988. [PMID: 36225971 PMCID: PMC9472471 DOI: 10.1016/j.electacta.2022.140988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 08/02/2022] [Accepted: 08/07/2022] [Indexed: 11/21/2022]
Abstract
The absence of reliable species-specific diagnostic tools for malaria at point-of-care (POC) remains a major setback towards effective disease management. This is partly due to the limited sensitivity and specificity of the current malaria POC diagnostic kits especially in cases of low-density parasitaemia and mixed species infections. In this study, we describe the first label-free DNA-based genosensors based on electrochemical impedance spectroscopy (EIS) for species-specific detection of P. falciparum, P. malariae and P. ovale. The limits of detection (LOD) for the three species-specific genosensors were down in attomolar concentrations ranging from 18.7 aM to 43.6 aM, which is below the detection limits of previously reported malaria genosensors. More importantly, the diagnostic performance of the three genosensors were compared to quantitative real-time polymerase chain reaction (qPCR) assays using purified genomic DNA and the paired whole blood lysates from clinical samples. Remarkably, all the qPCR-positive purified genomic DNA samples were correctly identified by the genosensors indicating 100% sensitivity for each of the three malaria species. The specificities of the three genosensors ranged from 66.7% to 100.0% with a Therapeutic Turnaround Time (TTAT) within 30 min, which is comparable to the TTAT of current POC diagnostic tools for malaria. This work represents a significant step towards the development of accurate and rapid species-specific nucleic acid-based toolkits for the diagnosis of malaria at the POC.
Collapse
Affiliation(s)
- Felix Ansah
- West African Centre for Cell Biology of Infectious Pathogens (WACCBIP), College of Basic and Applied Sciences, University of Ghana, Legon, Accra, Ghana
- Department of Biochemistry, Cell and Molecular Biology, College of Basic and Applied Sciences, University of Ghana, Legon, Accra, Ghana
| | - Francis Krampa
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Philippa Fawcett Drive, Cambridge,CB3 0AS, United Kingdom
| | - Jacob K. Donkor
- Department of Biochemistry, Cell and Molecular Biology, College of Basic and Applied Sciences, University of Ghana, Legon, Accra, Ghana
| | - Caleb Owusu-Appiah
- West African Centre for Cell Biology of Infectious Pathogens (WACCBIP), College of Basic and Applied Sciences, University of Ghana, Legon, Accra, Ghana
| | - Sarah Ashitei
- West African Centre for Cell Biology of Infectious Pathogens (WACCBIP), College of Basic and Applied Sciences, University of Ghana, Legon, Accra, Ghana
| | - Victor E. Kornu
- Department of Biochemistry, Cell and Molecular Biology, College of Basic and Applied Sciences, University of Ghana, Legon, Accra, Ghana
| | - Reinhard K. Danku
- West African Centre for Cell Biology of Infectious Pathogens (WACCBIP), College of Basic and Applied Sciences, University of Ghana, Legon, Accra, Ghana
| | - Jersley D. Chirawurah
- West African Centre for Cell Biology of Infectious Pathogens (WACCBIP), College of Basic and Applied Sciences, University of Ghana, Legon, Accra, Ghana
- Department of Biochemistry, Cell and Molecular Biology, College of Basic and Applied Sciences, University of Ghana, Legon, Accra, Ghana
| | - Gordon A. Awandare
- West African Centre for Cell Biology of Infectious Pathogens (WACCBIP), College of Basic and Applied Sciences, University of Ghana, Legon, Accra, Ghana
- Department of Biochemistry, Cell and Molecular Biology, College of Basic and Applied Sciences, University of Ghana, Legon, Accra, Ghana
| | - Yaw Aniweh
- West African Centre for Cell Biology of Infectious Pathogens (WACCBIP), College of Basic and Applied Sciences, University of Ghana, Legon, Accra, Ghana
| | - Prosper Kanyong
- West African Centre for Cell Biology of Infectious Pathogens (WACCBIP), College of Basic and Applied Sciences, University of Ghana, Legon, Accra, Ghana
- Siemens Healthineers, Siemens Healthcare Diagnostics Products Ltd, Llanberis, Gwynedd LL55 4EL, United Kingdom
| |
Collapse
|
12
|
Comparative Assessment of the Sensitivity of Ten Commercial Rapid Diagnostic Test Kits for the Detection of Plasmodium. Diagnostics (Basel) 2022; 12:diagnostics12092240. [PMID: 36140641 PMCID: PMC9498274 DOI: 10.3390/diagnostics12092240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 09/09/2022] [Accepted: 09/15/2022] [Indexed: 11/17/2022] Open
Abstract
Malaria is one of the most common tropical diseases encountered by members of the French military who are deployed in operations under constrained conditions in malaria-endemic areas. Blood smear microscopy—the gold standard for malaria diagnosis—is often not available in such settings, where the detection of malaria relies on rapid diagnostic tests (RDTs). Ten RDTs (from Biosynex, Carestart, Humasis, SD Bioline, and CTK Biotech), based on the detection of the Plasmodium falciparum histidine-rich protein 2 (HRP2) or lactate dehydrogenase (pLDH, PfLDH, or PvLDH), were assessed against 159 samples collected from imported malaria cases, including 79 P. falciparum, 37 P. vivax, 22 P. ovale, and 21 P. malariae parasites. Samples had been previously characterised using microscopy and real-time PCR. The overall sensitivities for the Plasmodium test ranged from 69.8% (111/159) to 95% (151/159). There was no significant difference for the specific detection of P. falciparum (96.2% to 98.7%, p = 0.845). No significant difference was found between sensitivities to P. vivax by pan LDH or pvLDH (81.1% (30/37) to 94.6% (35/37) (p = 0.845)). Some of the RDTs missed most of P. ovale and P. malariae, with sensitivities for all RDTs ranging respectively from 4.5% (1/22) to 81.8% (18/22) and 14.3% (3/21) to 95.2% (20/21). Carestart Malaria Pf/Pan (pLDH) Ag G0121, a pLDH-based RDT (PfLDH and pLDH), showed the highest sensitivities to P. falciparum (98.7%, 78/79), P. vivax (94.6%, 35/37), P. ovale (81.8%, 18/22), and P. malariae (95.2%, 20/21) and meets the requirements for military deployments in malaria-endemic areas.
Collapse
|
13
|
Martín-Ramírez A, Lanza M, Hisam S, Perez-Ayala A, Rubio JM. Usefulness of a commercial LAMP assay for detection of malaria infection, including Plasmodium knowlesi cases, in returning travelers in Spain. BMC Res Notes 2022; 15:147. [PMID: 35468833 PMCID: PMC9036737 DOI: 10.1186/s13104-022-06037-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 04/11/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Objective
Main malaria diagnosis is based on microscopic examination combined with rapid diagnostic tests. Both methods have low sensitivity and specificity. Loop-mediated isothermal amplification techniques have shown a sensitivity similar to PCR but with lower times of performance. This study aimed to assess a commercial LAMP for the diagnosis of malaria (Alethia® Malaria) against the Nested-Multiplex-Malaria PCR, including the analytical sensitivity and the operational characteristics.
Results
One hundred five samples out of 114 rendered valid results, obtaining 85 positive samples and 18 negative samples with an agreement of 98% compared to the reference method with a sensitivity, specificity and kappa coefficient of 98.84%, 94.74% and 0.94 respectively, with only two discrepant samples. The turnaround time was estimated in 1 h and 30 min, with a cost of 32.67€ per determination. The results showed several advantages of the Alethia® Malaria, as it was easy to perform, minimal training requirement and 40 min run. Moreover, it includes an internal control to avoid false negatives. However, it also showed some limitations such as the need for a specific amplification and detection device, the detection of only Plasmodium spp. and a very high price.
Collapse
|
14
|
Khartabil TA, de Rijke YB, Koelewijn R, van Hellemond JJ, Russcher H. Fast detection and quantification of Plasmodium species infected erythrocytes in a non-endemic region by using the Sysmex XN-31 analyzer. Malar J 2022; 21:119. [PMID: 35410230 PMCID: PMC8995682 DOI: 10.1186/s12936-022-04147-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 03/30/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Due to increased travel from endemic countries, malaria occurs more frequently in non-endemic regions. It is a challenge for diagnostic laboratories in non-endemic countries to provide reliable results, as experience of staff is often limited to only a few cases per year. This study evaluated the diagnostic accuracy of the fully automated Sysmex XN-31 malaria analyzer in a routine diagnostic setting in a non-endemic region was evaluated.
Methods
Samples from 112 patients suspected for malaria were examined by the Sysmex XN-31 analyzer to determine the absolute count of malaria-infected red blood cells count (MI-RBC/µL). Microscopic examination of both Quantitative Buffy Coat capillary tubes and thick and thin blood films were used as reference methods. Limits of blank (LoB), detection (LoD) and quantification (LoQ) were investigated using an in vitro Plasmodium falciparum culture. Nine hundred twenty samples of patients with RBC abnormalities were included to determine which RBC abnormalities trigger indeterminate or false positive results.
Results
No false positive nor false negative results were obtained for the examined patient samples suspected for malaria. For 3% of samples an indeterminate result by the XN-31 was obtained. The Passing-Bablok regression line for diagnostic accuracy of the parasitaemia was y = 39.75 + 0.7892 × showing a positive bias of about 21% when comparing the MI-RBC results to microscopy. The LoB, LoD and LoQ were calculated to be 4.7, 5.9, and 19.0 infected RBC/μL, respectively. From the 920 abnormal RBC samples collected, 4.6% resulted in a false positive MI-RBC result and almost half of the samples produced indeterminate results. These results were related to increases in nucleated red blood cells, reticulocytes and other abnormal RBC morphologies such as sickle cells.
Conclusions
Based on the results, the XN-31 is a fast and reliable screening method in the detection and quantification of Plasmodium species in patients However, if an abnormal red blood cell morphology is present, the results of the XN-31 should be interpreted with caution as false positive results can be caused by interfering abnormal erythrocytes.
Collapse
|
15
|
Clinical accuracy of malaria loop-mediated isothermal amplification assay as a stand-alone screening tool at a non-endemic Northern California regional health system. Diagn Microbiol Infect Dis 2022; 103:115680. [DOI: 10.1016/j.diagmicrobio.2022.115680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 02/18/2022] [Accepted: 03/04/2022] [Indexed: 11/17/2022]
|
16
|
Antinori S, Ridolfo AL, Grande R, Galimberti L, Casalini G, Giacomelli A, Milazzo L. Loop-mediated isothermal amplification (LAMP) assay for the diagnosis of imported malaria: a narrative review. LE INFEZIONI IN MEDICINA 2022; 29:355-365. [PMID: 35146340 DOI: 10.53854/liim-2903-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 08/09/2021] [Indexed: 11/03/2022]
Abstract
Loop-mediated isothermal amplification (LAMP) is a molecular method to detect malaria recently introduced in the market. LAMP is simple to perform and does not require advanced equipment and training thus satisfying the qualification as a point-of-care diagnostic screening test. In this narrative review, we focus on the role of LAMP for malaria diagnosis in non-endemic settings. We searched PubMed, Embase, Scopus, and Google Scholar, using the following search terms: 'Malaria LAMP' in combination with 'imported malaria' or 'travellers' malaria' or 'non-endemic setting' or 'non-endemic region' or 'malaria screening' or 'malaria diagnosis'. References of each article were also reviewed for possible studies or reports not identified in our search. Overall, 18 studies encompassing 6289 tested samples with 1663 confirmed malaria diagnoses were retrieved. Most of these studies (13/18, 72.2%) were conducted in Europe, and almost half were retrospective. Fourteen studies (77.8%) employed real-time or nested-polymerase chain reaction as the reference method for confirming malaria diagnosis. Sensitivity of LAMP ranged from 93.9 to 100% and specificity from 93.8 to 100% with a negative predictive value of 99.6%-100%. The rate of reported invalid results requiring repeat of the test varied from 0.01% to 5.7%, but they were solved in the majority of cases with a secondary analysis. In non-endemic countries the adoption of LAMP malaria assay as the screening test for malaria diagnosis seems to perform better than conventional methods. However, blood microscopy remains essential to either identify Plasmodium species and quantify parasitaemia and adequately managing malaria cases.
Collapse
Affiliation(s)
- Spinello Antinori
- Department of Biomedical and Clinical Sciences "Luigi Sacco", Università degli Studi di Milano, Milano, Italy.,III Division of Infectious Diseases, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Milano, Italy
| | - Anna Lisa Ridolfo
- III Division of Infectious Diseases, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Milano, Italy
| | - Romualdo Grande
- Clinical Microbiology, Virology and Bioemergency, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Milano, Italy
| | - Laura Galimberti
- III Division of Infectious Diseases, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Milano, Italy
| | - Giacomo Casalini
- Department of Biomedical and Clinical Sciences "Luigi Sacco", Università degli Studi di Milano, Milano, Italy
| | - Andrea Giacomelli
- Department of Biomedical and Clinical Sciences "Luigi Sacco", Università degli Studi di Milano, Milano, Italy.,III Division of Infectious Diseases, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Milano, Italy
| | - Laura Milazzo
- III Division of Infectious Diseases, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Milano, Italy
| |
Collapse
|
17
|
Giacomelli A, Monti ME, Grande R, Oreni L, Galimberti L, Ridolfo AL, Bonazzetti C, Sabaini F, Cordier L, Zambelli A, Rizzardini G, Galli M, Antinori S. The value of lamp to rule out imported malaria diagnosis: a retrospective observational study in Milan, Italy. Infect Dis (Lond) 2022; 54:410-417. [PMID: 34983306 DOI: 10.1080/23744235.2021.2023754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND The diagnosis of malaria in returning travellers could be a challenge in non-endemic settings. We aimed to assess the performance of LAMP in comparison with standard conventional diagnostic methods using real-time-polymerase chain reaction (PCR) in case of discordant results. METHODS All travellers returning from malaria-endemic areas who presented to our Emergency Department (ED) from January 2017 to December 2020 with signs and symptoms suggestive for malaria were included. Blood microscopy was the reference diagnostic method applied at our laboratory with LAMP implemented as an additional method to aid in malaria diagnosis. PCR was employed only in case of between test's discordant results. Sensitivity and specificity of microscopy compared to LAMP were calculated with the confidence interval of 95%. RESULTS Four-hundred and eight patients (55.6% male, median age 42 years) were screened for malaria. The diagnosis was confirmed in 49 cases (12%): 44 cases (90%) caused by Plasmodium falciparum. Peripheral blood smear missed to identify three malaria cases, which tested positive with LAMP and PCR. One case of malaria caused by P. malariae in a naive tourist, one case by P. falciparum in a semi-immune pregnant women and one case by P. falciparum in a previously treated semi-immune patient. All the discordant cases were characterized by a very low parasitaemia. Microscopy when compared to LAMP showed a sensitivity of 93.9% (95% confidence interval (CI) 83.1-98.7%) and a specificity of 100% (95% CI 98.9-100%). CONCLUSIONS In our non-endemic setting LAMP was able to identify malaria cases with low-level parasitaemia otherwise missed by blood microscopy.
Collapse
Affiliation(s)
- Andrea Giacomelli
- Department of Infectious Diseases, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy
| | - Maria Elena Monti
- Department of Infectious Diseases, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy
| | - Romualdo Grande
- Diagnostic Services, Clinical Microbiology, Virology and Bioemergence Diagnostics, ASST Fatebenefratelli-Sacco, Milan, Italy
| | - Letizia Oreni
- Department of Infectious Diseases, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy
| | - Laura Galimberti
- Department of Infectious Diseases, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy
| | - Anna Lisa Ridolfo
- Department of Infectious Diseases, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy
| | - Cecilia Bonazzetti
- Department of Infectious Diseases, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy.,Luigi Sacco Department of Biomedical and Clinical Sciences DIBIC, Università degli Studi di Milano, Milan, Italy
| | - Federico Sabaini
- Department of Infectious Diseases, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy
| | - Laura Cordier
- Department of Infectious Diseases, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy
| | - Agostino Zambelli
- Department of Infectious Diseases, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy
| | - Giuliano Rizzardini
- Department of Infectious Diseases, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy.,School of Clinical Medicine, Faculty of Health Science, University of the Witwatersrand, Johannesburg, South Africa
| | - Massimo Galli
- Department of Infectious Diseases, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy.,Luigi Sacco Department of Biomedical and Clinical Sciences DIBIC, Università degli Studi di Milano, Milan, Italy
| | - Spinello Antinori
- Department of Infectious Diseases, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy.,Luigi Sacco Department of Biomedical and Clinical Sciences DIBIC, Università degli Studi di Milano, Milan, Italy
| |
Collapse
|
18
|
Calderaro A, Montecchini S, Buttrini M, Piccolo G, Rossi S, Arcangeletti MC, Farina B, De Conto F, Chezzi C. Malaria Diagnosis in Non-Endemic Settings: The European Experience in the Last 22 Years. Microorganisms 2021; 9:microorganisms9112265. [PMID: 34835391 PMCID: PMC8620059 DOI: 10.3390/microorganisms9112265] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 10/25/2021] [Accepted: 10/26/2021] [Indexed: 11/16/2022] Open
Abstract
Accurate, prompt, and reliable tools for the diagnosis of malaria are crucial for tracking the successes or drawbacks of control and elimination efforts, and for future programs aimed at global malaria eradication. Although microscopy remains the gold standard method, the number of imported malaria cases and the risk of reappearance of autochthonous cases stimulated several laboratories located in European countries to evaluate methods and algorithms suited to non-endemic settings, where skilled microscopists are not always available. In this review, an overview of the field evaluation and a comparison of the methods used for the diagnosis of malaria by European laboratories is reported, showing that the development of numerous innovations is continuous. In particular, the combination of rapid diagnostic tests and molecular assays with microscopy represents a reliable system for the early diagnosis of malaria in non-endemic settings.
Collapse
Affiliation(s)
- Adriana Calderaro
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
- Correspondence: ; Tel.: +39-0521-033499; Fax: +39-0521-993620
| | - Sara Montecchini
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| | - Mirko Buttrini
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| | - Giovanna Piccolo
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| | - Sabina Rossi
- Unit of Clinical Microbiology, University Hospital of Parma, Viale A. Gramsci 14, 43126 Parma, Italy;
| | - Maria Cristina Arcangeletti
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| | - Benedetta Farina
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| | - Flora De Conto
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| | - Carlo Chezzi
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| |
Collapse
|
19
|
Boonstra MB, Koelewijn R, Brienen EAT, Silvis W, Stelma FF, Mank TG, Mulder B, van Lieshout L, van Hellemond JJ. Malaria diagnosis in a malaria non-endemic high-resource country: high variation of diagnostic strategy in clinical laboratories in the Netherlands. Malar J 2021; 20:411. [PMID: 34666766 PMCID: PMC8524939 DOI: 10.1186/s12936-021-03889-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Accepted: 08/20/2021] [Indexed: 11/10/2022] Open
Abstract
Background Microscopic examination of thick and thin blood films is the gold standard in current guidelines for the diagnosis of malaria, but guidelines do not uniformly agree on which combination of other methods should be used and when. Methods Three questionnaires were sent between March 2018 and September 2019 to laboratories subscribing to the external quality assessment scheme for the diagnosis of blood and intestinal parasites of the Dutch Foundation for Quality Assessment in Medical Laboratories in order to investigate how much variation in the laboratory diagnosis of malaria between different clinical laboratories is present in the Netherlands. Results The questionnaires were partially or fully completed by 67 of 77 (87%) laboratories. Only 9 laboratories reported 10 or more malaria positive patients per year. Most laboratories use a different diagnostic strategy, within office versus outside office hours depending on the screening assay result. Within office hours, 62.5% (35/56) of the responding laboratories perform an immunochromatographic test (ICT) in combination with microscopic examination of thick and thin blood films without additional examinations, such as Quantitative Buffy Coat and/or rtPCR analysis. Outside office hours 85.7% (48/56) of laboratories use an ICT as single screening assay and positive results are immediately confirmed by thick and thin blood films without additional examinations (89.6%, 43/48). In case of a negative ICT result outside office hours, 70.8% (34/48) of the laboratories perform microscopic examination of the thick film the next morning and 22.9% (11/48) confirm the negative ICT result immediately. Furthermore, substantial differences were found in the microscopic examinations of thick and thin blood films; the staining, theoretical sensitivity of the thick film and determination of parasitaemia. Conclusions This study demonstrated a remarkably high variation between laboratories in both their diagnostic strategy as well as their methods for microscopic examination for the diagnosis of malaria in a clinical setting, despite existing national and international guidelines. While the impact of these variations on the accuracy of the diagnosis of malaria is yet unknown, these findings should stimulate clinical laboratories to critically review their own diagnostic strategy. Supplementary Information The online version contains supplementary material available at 10.1186/s12936-021-03889-7.
Collapse
Affiliation(s)
- Marrit B Boonstra
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Rob Koelewijn
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Eric A T Brienen
- Department of Parasitology, Leiden University Medical Centre, Leiden, The Netherlands
| | - Welmoed Silvis
- Laboratory for Medical Microbiology and Public Health (LabMicTA), Hengelo, The Netherlands
| | - Foekje F Stelma
- Department of Medical Microbiology, Radboudumc, Nijmegen, The Netherlands
| | - Theo G Mank
- Regional Laboratory for Medical Microbiology and Public Health, Haarlem, The Netherlands
| | - Bert Mulder
- Department of Medical Microbiology, Canisius-Wilhelmina Hospital, Nijmegen, The Netherlands
| | - Lisette van Lieshout
- Department of Parasitology, Leiden University Medical Centre, Leiden, The Netherlands
| | - Jaap J van Hellemond
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
| |
Collapse
|
20
|
Schneider R, Lamien-Meda A, Auer H, Wiedermann-Schmidt U, Chiodini PL, Walochnik J. Validation of a novel FRET real-time PCR assay for simultaneous quantitative detection and discrimination of human Plasmodium parasites. PLoS One 2021; 16:e0252887. [PMID: 34086817 PMCID: PMC8177637 DOI: 10.1371/journal.pone.0252887] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Accepted: 05/25/2021] [Indexed: 11/19/2022] Open
Abstract
Increasing numbers of travelers returning from endemic areas, migrants, and refugees have led to a significant rise in the number of imported malaria cases in non-endemic countries. Real- time PCR serves as an excellent diagnostic tool, especially in regions where experience in microscopy is limited. A novel fluorescence resonance energy transfer-based real-time PCR (FRET-qPCR) was developed and evaluated using 56 reference samples of the United Kingdom National External Quality Assessment Service (UK NEQAS) for molecular detection of malaria, including P. falciparum, P. vivax, P. ovale, P. malariae, and P. knowlesi. Species identification is based on single nucleotide polymorphisms (SNPs) within the genome where the MalLC640 probe binds, lowering the melting temperature in the melting curve analysis. The novel FRET-qPCR achieved 100% (n = 56) correct results, compared to 96.43% performing nested PCR. The high sensitivity, with a calculated limit of detection of 199.97 parasites/mL blood for P. falciparum, is a significant advantage, especially if low-level parasitemia has to be ruled out. Even mixed infections of P. falciparum with P. vivax or P. ovale, respectively, were detected. In contrast to many other real-time PCR protocols, this novel FRET-qPCR allows the quantitative and species-specific detection of Plasmodium spp. in one single run. Solely, P. knowlesi was detected but could not be differentiated from P. vivax. The turnaround time of this novel FRET-qPCR including DNA extraction is less than two hours, qualifying it for routine clinical applications, including treatment monitoring.
Collapse
Affiliation(s)
- Renate Schneider
- Institute for Specific Prophylaxis and Tropical Medicine, Center for Pathophysiology, Infectiology and Immunology, Medical University of Vienna, Vienna, Austria
| | - Aline Lamien-Meda
- Institute for Specific Prophylaxis and Tropical Medicine, Center for Pathophysiology, Infectiology and Immunology, Medical University of Vienna, Vienna, Austria
| | - Herbert Auer
- Institute for Specific Prophylaxis and Tropical Medicine, Center for Pathophysiology, Infectiology and Immunology, Medical University of Vienna, Vienna, Austria
| | - Ursula Wiedermann-Schmidt
- Institute for Specific Prophylaxis and Tropical Medicine, Center for Pathophysiology, Infectiology and Immunology, Medical University of Vienna, Vienna, Austria
| | - Peter L. Chiodini
- UK NEQAS Parasitology, Public Health England, London, United Kingdom
| | - Julia Walochnik
- Institute for Specific Prophylaxis and Tropical Medicine, Center for Pathophysiology, Infectiology and Immunology, Medical University of Vienna, Vienna, Austria
- * E-mail:
| |
Collapse
|
21
|
Malaria Rapid Diagnostic Tests: Literary Review and Recommendation for a Quality Assurance, Quality Control Algorithm. Diagnostics (Basel) 2021; 11:diagnostics11050768. [PMID: 33922917 PMCID: PMC8145891 DOI: 10.3390/diagnostics11050768] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 04/20/2021] [Accepted: 04/21/2021] [Indexed: 01/24/2023] Open
Abstract
Malaria rapid diagnostic tests (RDTs) have had an enormous global impact which contributed to the World Health Organization paradigm shift from empiric treatment to obtaining a parasitological diagnosis prior to treatment. Microscopy, the classic standard, requires significant expertise, equipment, electricity, and reagents. Alternatively, RDT’s lower complexity allows utilization in austere environments while achieving similar sensitivities and specificities. Worldwide, there are over 200 different RDT brands that utilize three antigens: Plasmodium histidine-rich protein 2 (PfHRP-2), Plasmodium lactate dehydrogenase (pLDH), and Plasmodium aldolase (pALDO). pfHRP-2 is produced exclusively by Plasmodium falciparum and is very Pf sensitive, but an alternative antigen or antigen combination is required for regions like Asia with significant Plasmodium vivax prevalence. RDT sensitivity also decreases with low parasitemia (<100 parasites/uL), genetic variability, and prozone effect. Thus, proper RDT selection and understanding of test limitations are essential. The Center for Disease Control recommends confirming RDT results by microscopy, but this is challenging, due to the utilization of clinical laboratory standards, like the College of American Pathologists (CAP) and the Clinical Lab Improvement Act (CLIA), and limited recourses. Our focus is to provide quality assurance and quality control strategies for resource-constrained environments and provide education on RDT limitations.
Collapse
|
22
|
Performance and Application of Commercially Available Loop-Mediated Isothermal Amplification (LAMP) Kits in Malaria Endemic and Non-Endemic Settings. Diagnostics (Basel) 2021; 11:diagnostics11020336. [PMID: 33670618 PMCID: PMC7922894 DOI: 10.3390/diagnostics11020336] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 02/13/2021] [Accepted: 02/15/2021] [Indexed: 01/04/2023] Open
Abstract
Loop-mediated isothermal amplification (LAMP) is a sensitive molecular tool suitable for use as a near point-of-care test for the diagnosis of malaria. Recent meta-analyses have detailed high sensitivity and specificity of malaria LAMP when compared to microscopy, rapid diagnostic tests, and polymerase chain reaction in both endemic and non-endemic settings. Despite this, the use of malaria LAMP has primarily been limited to research settings to date. In this review, we aim to assess to what extent commercially available malaria LAMP kits have been applied in different settings, and to identify possible obstacles that may have hindered their use from being adopted further. In order to address this, we conducted a literature search in PubMed.gov using the search terms (((LAMP) OR (Loop-mediated isothermal amplification)) AND ((Malaria) OR (Plasmodium))). Focusing primarily on studies employing one of the commercially available kits, we then selected three key areas of LAMP application for further review: the performance and application of LAMP in malaria endemic settings including low transmission areas; LAMP for malaria screening during pregnancy; and malaria LAMP in returning travelers in non-endemic settings.
Collapse
|
23
|
Holmström O, Stenman S, Suutala A, Moilanen H, Kücükel H, Ngasala B, Mårtensson A, Mhamilawa L, Aydin-Schmidt B, Lundin M, Diwan V, Linder N, Lundin J. A novel deep learning-based point-of-care diagnostic method for detecting Plasmodium falciparum with fluorescence digital microscopy. PLoS One 2020; 15:e0242355. [PMID: 33201905 PMCID: PMC7671488 DOI: 10.1371/journal.pone.0242355] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Accepted: 10/30/2020] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Malaria remains a major global health problem with a need for improved field-usable diagnostic tests. We have developed a portable, low-cost digital microscope scanner, capable of both brightfield and fluorescence imaging. Here, we used the instrument to digitize blood smears, and applied deep learning (DL) algorithms to detect Plasmodium falciparum parasites. METHODS Thin blood smears (n = 125) were collected from patients with microscopy-confirmed P. falciparum infections in rural Tanzania, prior to and after initiation of artemisinin-based combination therapy. The samples were stained using the 4',6-diamidino-2-phenylindole fluorogen and digitized using the prototype microscope scanner. Two DL algorithms were trained to detect malaria parasites in the samples, and results compared to the visual assessment of both the digitized samples, and the Giemsa-stained thick smears. RESULTS Detection of P. falciparum parasites in the digitized thin blood smears was possible both by visual assessment and by DL-based analysis with a strong correlation in results (r = 0.99, p < 0.01). A moderately strong correlation was observed between the DL-based thin smear analysis and the visual thick smear-analysis (r = 0.74, p < 0.01). Low levels of parasites were detected by DL-based analysis on day three following treatment initiation, but a small number of fluorescent signals were detected also in microscopy-negative samples. CONCLUSION Quantification of P. falciparum parasites in DAPI-stained thin smears is feasible using DL-supported, point-of-care digital microscopy, with a high correlation to visual assessment of samples. Fluorescent signals from artefacts in samples with low infection levels represented the main challenge for the digital analysis, thus highlighting the importance of minimizing sample contaminations. The proposed method could support malaria diagnostics and monitoring of treatment response through automated quantification of parasitaemia and is likely to be applicable also for diagnostics of other Plasmodium species and other infectious diseases.
Collapse
Affiliation(s)
- Oscar Holmström
- Institute for Molecular Medicine Finland (FIMM), University of Helsinki, Helsinki, Finland
- * E-mail:
| | - Sebastian Stenman
- Institute for Molecular Medicine Finland (FIMM), University of Helsinki, Helsinki, Finland
| | - Antti Suutala
- Institute for Molecular Medicine Finland (FIMM), University of Helsinki, Helsinki, Finland
| | - Hannu Moilanen
- Center of Microscopy and Nanotechnology, University of Oulu, Oulu, Finland
| | - Hakan Kücükel
- Institute for Molecular Medicine Finland (FIMM), University of Helsinki, Helsinki, Finland
| | - Billy Ngasala
- Department of Women’s and Children’s Health, International Maternal and Child Health (IMCH), Uppsala University, Uppsala, Sweden
- Department of Medical Entomology and Parasitology, School of Public Health, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
| | - Andreas Mårtensson
- Department of Women’s and Children’s Health, International Maternal and Child Health (IMCH), Uppsala University, Uppsala, Sweden
| | - Lwidiko Mhamilawa
- Department of Women’s and Children’s Health, International Maternal and Child Health (IMCH), Uppsala University, Uppsala, Sweden
- Department of Medical Entomology and Parasitology, School of Public Health, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
| | - Berit Aydin-Schmidt
- Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet, Stockholm, Sweden
| | - Mikael Lundin
- Institute for Molecular Medicine Finland (FIMM), University of Helsinki, Helsinki, Finland
| | - Vinod Diwan
- Department of Global Public Health, Karolinska Institutet, Stockholm, Sweden
| | - Nina Linder
- Institute for Molecular Medicine Finland (FIMM), University of Helsinki, Helsinki, Finland
- Department of Women’s and Children’s Health, International Maternal and Child Health (IMCH), Uppsala University, Uppsala, Sweden
| | - Johan Lundin
- Institute for Molecular Medicine Finland (FIMM), University of Helsinki, Helsinki, Finland
- Department of Global Public Health, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
24
|
Zhao OS, Kolluri N, Anand A, Chu N, Bhavaraju R, Ojha A, Tiku S, Nguyen D, Chen R, Morales A, Valliappan D, Patel JP, Nguyen K. Convolutional neural networks to automate the screening of malaria in low-resource countries. PeerJ 2020; 8:e9674. [PMID: 32832279 PMCID: PMC7413078 DOI: 10.7717/peerj.9674] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 07/16/2020] [Indexed: 12/27/2022] Open
Abstract
Malaria is an infectious disease caused by Plasmodium parasites, transmitted through mosquito bites. Symptoms include fever, headache, and vomiting, and in severe cases, seizures and coma. The World Health Organization reports that there were 228 million cases and 405,000 deaths in 2018, with Africa representing 93% of total cases and 94% of total deaths. Rapid diagnosis and subsequent treatment are the most effective means to mitigate the progression into serious symptoms. However, many fatal cases have been attributed to poor access to healthcare resources for malaria screenings. In these low-resource settings, the use of light microscopy on a thin blood smear with Giemsa stain is used to examine the severity of infection, requiring tedious and manual counting by a trained technician. To address the malaria endemic in Africa and its coexisting socioeconomic constraints, we propose an automated, mobile phone-based screening process that takes advantage of already existing resources. Through the use of convolutional neural networks (CNNs), we utilize a SSD multibox object detection architecture that rapidly processes thin blood smears acquired via light microscopy to isolate images of individual red blood cells with 90.4% average precision. Then we implement a FSRCNN model that upscales 32 × 32 low-resolution images to 128 × 128 high-resolution images with a PSNR of 30.2, compared to a baseline PSNR of 24.2 through traditional bicubic interpolation. Lastly, we utilize a modified VGG16 CNN that classifies red blood cells as either infected or uninfected with an accuracy of 96.5% in a balanced class dataset. These sequential models create a streamlined screening platform, giving the healthcare provider the number of malaria-infected red blood cells in a given sample. Our deep learning platform is efficient enough to operate exclusively on low-tier smartphone hardware, eliminating the need for high-speed internet connection.
Collapse
Affiliation(s)
- Oliver S Zhao
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Nikhil Kolluri
- Department of Electrical & Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Anagata Anand
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Nicholas Chu
- Department of Electrical & Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Ravali Bhavaraju
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Aditya Ojha
- Department of Electrical & Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Sandhya Tiku
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Dat Nguyen
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Ryan Chen
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Adriane Morales
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Deepti Valliappan
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Juhi P Patel
- Department of Psychology, The University of Texas at Austin, Austin, TX, United States of America
| | - Kevin Nguyen
- Department of Psychology, The University of Texas at Austin, Austin, TX, United States of America
| |
Collapse
|
25
|
Pasquier G, Azoury V, Sasso M, Laroche L, Varlet-Marie E, Houzé S, Lachaud L, Bastien P, Sterkers Y, Leveque MF. Rapid diagnostic tests failing to detect infections by Plasmodium falciparum encoding pfhrp2 and pfhrp3 genes in a non-endemic setting. Malar J 2020; 19:179. [PMID: 32393251 PMCID: PMC7216663 DOI: 10.1186/s12936-020-03251-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Accepted: 05/01/2020] [Indexed: 11/10/2022] Open
Abstract
Background Rapid diagnostic tests (RDTs) detecting the histidine-rich protein 2 (PfHRP2) have a central position for the management of Plasmodium falciparum infections. Yet, variable detection of certain targeted motifs, low parasitaemia, but also deletion of pfhrp2 gene or its homologue pfhrp3, may result in false-negative RDT leading to misdiagnosis and delayed treatment. This study aimed at investigating the prevalence, and understanding the possible causes, of P. falciparum RDT-negative infections at Montpellier Academic Hospital, France. Methods The prevalence of falsely-negative RDT results reported before and after the introduction of a loop-mediated isothermal amplification (LAMP) assay, as part as the malaria screening strategy in January 2017, was analysed. Negative P. falciparum RDT infections were screened for pfhrp2 or pfhrp3 deletion; and exons 2 were sequenced to show a putative genetic diversity impairing PfHRP2 detection. Results The overall prevalence of P. falciparum negative RDTs from January 2006 to December 2018 was low (3/446). Whereas no cases were reported from 2006 to 2016 (0/373), period during which the malaria diagnostic screen was based on microscopy and RDT, prevalence increased up to 4.1% (3/73) between 2017 and 2018, when molecular detection was implemented for primary screening. Neither pfhrp2/3 deletion nor major variation in the frequency of repetitive epitopes could explain these false-negative RDT results. Conclusion This paper demonstrates the presence of pfhrp2 and pfhrp3 genes in three P. falciparum RDT-negative infections and reviews the possible reasons for non-detection of HRP2/3 antigens in a non-endemic setting. It highlights the emergence of falsely negative rapid diagnostic tests in a non-endemic setting and draws attention on the risk of missing malaria cases with low parasitaemia infections using the RDT plus microscopy-based strategy currently recommended by French authorities. The relevance of a novel diagnostic scheme based upon a LAMP assay is discussed.
Collapse
Affiliation(s)
- Grégoire Pasquier
- University of Montpellier, CNRS, IRD, UMR MiVEGEC, Montpellier, France.,Department of Parasitology-Mycology, CHU de Montpellier, Montpellier, France
| | - Vincent Azoury
- Department of Parasitology-Mycology, CHU de Montpellier, Montpellier, France
| | - Milène Sasso
- University of Montpellier, CNRS, IRD, UMR MiVEGEC, Montpellier, France.,Laboratory of Microbiology, CHU de Nîmes, Nîmes, France
| | - Laëtitia Laroche
- Department of Parasitology-Mycology, CHU de Montpellier, Montpellier, France
| | | | - Sandrine Houzé
- Centre National de Référence du Paludisme, APHP, Hôpital Bichat-Claude Bernard, Paris, France
| | - Laurence Lachaud
- University of Montpellier, CNRS, IRD, UMR MiVEGEC, Montpellier, France.,Department of Parasitology-Mycology, CHU de Montpellier, Montpellier, France
| | - Patrick Bastien
- University of Montpellier, CNRS, IRD, UMR MiVEGEC, Montpellier, France.,Department of Parasitology-Mycology, CHU de Montpellier, Montpellier, France
| | - Yvon Sterkers
- University of Montpellier, CNRS, IRD, UMR MiVEGEC, Montpellier, France.,Department of Parasitology-Mycology, CHU de Montpellier, Montpellier, France
| | - Maude F Leveque
- University of Montpellier, CNRS, IRD, UMR MiVEGEC, Montpellier, France. .,Department of Parasitology-Mycology, CHU de Montpellier, Montpellier, France.
| |
Collapse
|
26
|
Chagas CRF, Binkienė R, Ilgūnas M, Iezhova T, Valkiūnas G. The buffy coat method: a tool for detection of blood parasites without staining procedures. Parasit Vectors 2020; 13:104. [PMID: 32103784 PMCID: PMC7045512 DOI: 10.1186/s13071-020-3984-8] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Accepted: 02/18/2020] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Blood parasites belonging to the Apicomplexa, Trypanosomatidae and Filarioidea are widespread in birds and have been studied extensively. Microscopical examination (ME) of stained blood films remains the gold standard method for the detection of these infections in birds, particularly because co-infections predominate in wildlife. None of the available molecular tools can detect all co-infections at the same time, but ME provides opportunities for this to be achieved. However, fixation, drying and staining of blood films as well as their ME are relatively time-consuming. This limits the detection of infected hosts during fieldwork when captured animals should be released soon after sampling. It is an obstacle for quick selection of donor hosts for parasite experimental, histological and other investigations in the field. This study modified, tested and described the buffy coat method (BCM) for quick diagnostics (~ 20 min/sample) of avian blood parasites. METHODS Blood of 345 birds belonging to 42 species was collected, and each sample was examined using ME of stained blood films and the buffy coat, which was examined after centrifugation in capillary tubes and after being transferred to objective glass slides. Parasite detection using these methods was compared using sensitivity, specificity, positive and negative predictive values and Cohen's kappa index. RESULTS Haemoproteus, Leucocytozoon, Plasmodium, microfilariae, Trypanosoma and Lankesterella parasites were detected. BCM had a high sensitivity (> 90%) and specificity (> 90%) for detection of Haemoproteus and microfilariae infections. It was of moderate sensitivity (57%) and high specificity (> 90%) for Lankesterella infections, but of low sensitivity (20%) and high specificity (> 90%) for Leucocytozoon infections. Trypanosoma and Plasmodium parasites were detected only by BCM and ME, respectively. According to Cohen's kappa index, the agreement between two diagnostic tools was substantial for Haemoproteus (0.80), moderate for Lankesterella (0.46) and fair for microfilariae and Leucocytozoon (0.28) infections. CONCLUSIONS BCM is sensitive and recommended as a quick and reliable tool to detect Haemoproteus, Trypanosoma and microfilariae parasites during fieldwork. However, it is not suitable for detection of species of Leucocytozoon and Plasmodium. BCM is a useful tool for diagnostics of blood parasite co-infections. Its application might be extended to studies of blood parasites in other vertebrates during field studies.
Collapse
Affiliation(s)
| | - Rasa Binkienė
- Nature Research Centre, Akademijos 2, 08412, Vilnius, Lithuania
| | - Mikas Ilgūnas
- Nature Research Centre, Akademijos 2, 08412, Vilnius, Lithuania
| | - Tatjana Iezhova
- Nature Research Centre, Akademijos 2, 08412, Vilnius, Lithuania
| | | |
Collapse
|
27
|
Norman FF, Comeche B, Chamorro S, López-Vélez R. Overcoming challenges in the diagnosis and treatment of parasitic infectious diseases in migrants. Expert Rev Anti Infect Ther 2020; 18:127-143. [PMID: 31914335 DOI: 10.1080/14787210.2020.1713099] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Introduction: Recent increases in population movements have created novel health challenges in many areas of the World, and health policies have been adapted accordingly in several countries. However, screening guidelines for infectious diseases are not standardized and generally do not include comprehensive screening for parasitic infections.Areas covered: Malaria, Chagas disease, leishmaniasis, amebiasis, filariases, strongyloidiasis, and schistosomiasis are reviewed, focusing on the challenges posed for their diagnosis and management in vulnerable populations such as migrants. The methodology included literature searches in public databases such as PubMed.gov and Google Scholar and search of the US National Library of Medicine online database of privately and publicly funded clinical studies (ClinicalTrials.gov) until November 2019.Expert opinion: Parasitic infections which may remain asymptomatic for prolonged periods, leading to chronic infection and complications, and/or may be transmitted in non-endemic areas are ideal candidates for screening. Proposed strategies to improve diagnosis in vulnerable groups such as migrants include facilitating access to healthcare in a multi-dimensional manner considering location, individual characteristics, and timing. Limitations and availability of specific diagnostic techniques should be addressed and focus on drug and vaccine development for these neglected infections should be prioritized through collaborative initiatives with public disclosure of results.
Collapse
Affiliation(s)
- Francesca F Norman
- National Referral Unit for Tropical Diseases, Infectious Diseases Department, Ramón y Cajal University Hospital, IRYCIS, Madrid, Spain
| | - Belen Comeche
- National Referral Unit for Tropical Diseases, Infectious Diseases Department, Ramón y Cajal University Hospital, IRYCIS, Madrid, Spain
| | - Sandra Chamorro
- National Referral Unit for Tropical Diseases, Infectious Diseases Department, Ramón y Cajal University Hospital, IRYCIS, Madrid, Spain
| | - Rogelio López-Vélez
- National Referral Unit for Tropical Diseases, Infectious Diseases Department, Ramón y Cajal University Hospital, IRYCIS, Madrid, Spain
| |
Collapse
|