1
|
Cao Y, Li P, Zhu Y, Wang Z, Tang N, Li Z, Cheng B, Wang F, Chen T, Sun L. Artificial Intelligence-Enabled Novel Atrial Fibrillation Diagnosis System Using 3D Pulse Perception Flexible Pressure Sensor Array. ACS Sens 2025; 10:272-282. [PMID: 39757849 DOI: 10.1021/acssensors.4c02395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2025]
Abstract
Atrial fibrillation (AF) as one of the most common cardiovascular diseases has attracted great attention due to its high disability and mortality rate. Thus, a timely and effective recognition method for AF is of great importance for diagnosing and preventing it. Herein, we proposed a novel intelligent sensing and recognition system for AF which combined Traditional Chinese Medicine (TCM), flexible wearable electronic devices, and artificial intelligence. Experiment and simulation synergistically verified that the flexible pressure sensor arrays designed according to the TCM theory could synchronously obtain the 3D pulses at Cun, Guan, and Chi. Combined with a homemade signal acquisition system and the pulse signals labeled by doctors of cardiovascular diseases, the differences in the 3D pulse signals between ones with AF and without can be picked up clearly. Enabled the convolutional neural network (CNN) and the pulse database, the recognition model was formed with a recognition rate of up to 90%. As a proof of concept, the artificial intelligence-enabled novel atrial fibrillation diagnosis system has been used to detect patients with AF in hospitals, showing 80% recognition rate. This work provides a new strategy to precisely diagnose and remotely treat AF, as well as to accelerate the development of Modern Chinese Medicine treatment.
Collapse
Affiliation(s)
- Yujie Cao
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215137, China
| | - Ping Li
- Shanghai University of Medicine & Health Sciences, Shanghai 201318, China
| | - Yirun Zhu
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215137, China
| | - Zheng Wang
- Department of GerontologyShanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai 200233, China
| | - Nuo Tang
- Cardiology Department, Longhua Hospital Shanghai University of Traditional Chinese Medicine, Shanghai 200032, China
| | - Zhibin Li
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215137, China
| | - Bin Cheng
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215137, China
| | - Fengxia Wang
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215137, China
| | - Tao Chen
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215137, China
| | - Lining Sun
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215137, China
| |
Collapse
|
2
|
Lisowicz J, Krupa K, Leksycki K, Rusinek R, Wojciechowski S. Analysis of Tool Wear in Finish Turning of Titanium Alloy Ti-6Al-4V Under Minimum Quantity Lubrication Conditions Observed with Recurrence Quantification Analysis. MATERIALS (BASEL, SWITZERLAND) 2024; 18:79. [PMID: 39795724 PMCID: PMC11721966 DOI: 10.3390/ma18010079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2024] [Revised: 12/20/2024] [Accepted: 12/26/2024] [Indexed: 01/13/2025]
Abstract
Titanium alloys, particularly Ti-6Al-4V, are widely used in many industries due to their high strength, low density, and corrosion resistance. However, machining these materials is challenging due to high strength at elevated temperatures, low thermal conductivity, and high chemical reactivity. This study investigates Recurrence Plot (RP) and Recurrence Quantification Analysis (RQA) to analyze tool wear during the finish turning of Ti-6Al-4V. The tests were conducted under Minimum Quantity Lubrication (MQL). Three inserts (two coated, one uncoated) were tested, and tool life was evaluated based on material removal volume. The issue of tool exploitation and process reliability is crucial, as it directly impacts machining performance. Results show that the uncoated insert outperformed the coated ones. RQA parameters indicated a stable-to-unstable transition in coated inserts but not in the uncoated insert. This suggests that recurrence analysis can monitor cutting dynamics in coated insert machining, but further research is needed for uncoated tools. This paper's novelty lies in applying RP and RQA to diagnose tool wear in titanium alloy machining under MQL conditions, a method not previously explored in this context.
Collapse
Affiliation(s)
- Joanna Lisowicz
- Department of Manufacturing Techniques and Automation, Faculty of Mechanical Engineering and Aeronautics, Rzeszow University of Technology, 12 Al. Powstancow Warszawy Street, 35-959 Rzeszow, Poland
| | - Krzysztof Krupa
- Department of Material Science, Faculty of Mechanical Engineering and Aeronautics, Rzeszow University of Technology, 12 Al. Powstancow Warszawy Street, 35-959 Rzeszow, Poland;
| | - Kamil Leksycki
- Institute of Mechanical Engineering, University of Zielona Gora, 4 Prof. Z. Szafrana Street, 65-516 Zielona Gora, Poland
| | - Rafał Rusinek
- Department of Applied Mechanics, Lublin University of Technology, Nadbystrzycka 36 Street, 20-618 Lublin, Poland;
| | - Szymon Wojciechowski
- Institute of Mechanical Technology, Poznan University of Technology, 3 Piotrowo Street, 60-965 Poznan, Poland;
- Department of Automobile and Manufacturing Technologies, Faculty of Manufacturing Technologies with a Seat in Presov, Technical University of Kosice, 31 Sturova Street, 080 01 Presov, Slovakia
| |
Collapse
|
3
|
Halfar R, Lawson BAJ, Dos Santos RW, Burrage K. Recurrence quantification analysis for fine-scale characterisation of arrhythmic patterns in cardiac tissue. Sci Rep 2023; 13:11828. [PMID: 37481668 PMCID: PMC10363137 DOI: 10.1038/s41598-023-38256-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Accepted: 07/05/2023] [Indexed: 07/24/2023] Open
Abstract
This paper uses recurrence quantification analysis (RQA) combined with entropy measures and organization indices to characterize arrhythmic patterns and dynamics in computer simulations of cardiac tissue. We performed different simulations of cardiac tissues of sizes comparable to the human heart atrium. In these simulations, we observed four classic arrhythmic patterns: a spiral wave anchored to a highly fibrotic region resulting in sustained re-entry, a meandering spiral wave, fibrillation, and a spiral wave anchored to a scar region that breaks up into wavelets away from the main rotor. A detailed analysis revealed that, within the same simulation, maps of RQA metrics could differentiate regions with regular AP propagation from ones with chaotic activity. In particular, the combination of two RQA metrics, the length of the longest diagonal string of recurrence points and the mean length of diagonal lines, was able to identify the location of rotor tips, which are the active elements that maintain spiral waves and fibrillation. By proposing low-dimensional models based on the mean value and spatial correlation of metrics calculated from membrane potential time series, we identify RQA-based metrics that successfully separate the four different types of cardiac arrhythmia into distinct regions of the feature space, and thus might be used for automatic classification, in particular distinguishing between fibrillation driven by self-sustaining chaos and that created by a persistent rotor and wavebreak. We also discuss the practical applicability of such an approach.
Collapse
Affiliation(s)
- Radek Halfar
- IT4Innovations, VSB - Technical University of Ostrava, 708 00, Ostrava, Czech Republic.
| | - Brodie A J Lawson
- ARC Centre of Excellence for Plant Success in Nature and Agriculture, Queensland University of Technology, Brisbane, 4000, Australia
- Centre for Data Science, Queensland Univeristy of Technology, Brisbane, 4000, Australia
| | - Rodrigo Weber Dos Santos
- Graduate Program in Computational Modeling, Universidade Federal de Juiz de Fora, Juiz de Fora, 36036-330, Brazil
| | - Kevin Burrage
- ARC Centre of Excellence for Plant Success in Nature and Agriculture, Queensland University of Technology, Brisbane, 4000, Australia
- Department of Computer Science, University of Oxford, Oxford, UK
| |
Collapse
|
4
|
Finotti E, Quesada A, Ciaccio EJ, Garan H, Hornero F, Alcaraz R, Rieta JJ. Practical Considerations for the Application of Nonlinear Indices Characterizing the Atrial Substrate in Atrial Fibrillation. ENTROPY (BASEL, SWITZERLAND) 2022; 24:1261. [PMID: 36141147 PMCID: PMC9497841 DOI: 10.3390/e24091261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 08/31/2022] [Accepted: 09/03/2022] [Indexed: 06/16/2023]
Abstract
Atrial fibrillation (AF) is the most common cardiac arrhythmia, and in response to increasing clinical demand, a variety of signals and indices have been utilized for its analysis, which include complex fractionated atrial electrograms (CFAEs). New methodologies have been developed to characterize the atrial substrate, along with straightforward classification models to discriminate between paroxysmal and persistent AF (ParAF vs. PerAF). Yet, most previous works have missed the mark for the assessment of CFAE signal quality, as well as for studying their stability over time and between different recording locations. As a consequence, an atrial substrate assessment may be unreliable or inaccurate. The objectives of this work are, on the one hand, to make use of a reduced set of nonlinear indices that have been applied to CFAEs recorded from ParAF and PerAF patients to assess intra-recording and intra-patient stability and, on the other hand, to generate a simple classification model to discriminate between them. The dominant frequency (DF), AF cycle length, sample entropy (SE), and determinism (DET) of the Recurrence Quantification Analysis are the analyzed indices, along with the coefficient of variation (CV) which is utilized to indicate the corresponding alterations. The analysis of the intra-recording stability revealed that discarding noisy or artifacted CFAE segments provoked a significant variation in the CV(%) in any segment length for the DET and SE, with deeper decreases for longer segments. The intra-patient stability provided large variations in the CV(%) for the DET and even larger for the SE at any segment length. To discern ParAF versus PerAF, correlation matrix filters and Random Forests were employed, respectively, to remove redundant information and to rank the variables by relevance, while coarse tree models were built, optimally combining high-ranked indices, and tested with leave-one-out cross-validation. The best classification performance combined the SE and DF, with an accuracy (Acc) of 88.3%, to discriminate ParAF versus PerAF, while the highest single Acc was provided by the DET, reaching 82.2%. This work has demonstrated that due to the high variability of CFAEs data averaging from one recording place or among different recording places, as is traditionally made, it may lead to an unfair oversimplification of the CFAE-based atrial substrate characterization. Furthermore, a careful selection of reduced sets of features input to simple classification models is helpful to accurately discern the CFAEs of ParAF versus PerAF.
Collapse
Affiliation(s)
- Emanuela Finotti
- BioMIT.org, Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain
| | - Aurelio Quesada
- Arrhythmia Unit, Cardiology Department, General University Hospital Consortium of Valencia, 46014 Valencia, Spain
| | - Edward J. Ciaccio
- Department of Medicine, Division of Cardiology, Columbia University Medical Center, New York, NY 10032, USA
| | - Hasan Garan
- Department of Medicine, Division of Cardiology, Columbia University Medical Center, New York, NY 10032, USA
| | - Fernando Hornero
- Cardiovascular Surgery Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain
| | - Raúl Alcaraz
- Research Group in Electronic, Biomedical and Telecommunication Engineering, University of Castilla-La Mancha, 16071 Cuenca, Spain
| | - José J. Rieta
- BioMIT.org, Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain
| |
Collapse
|
5
|
Murat F, Sadak F, Yildirim O, Talo M, Murat E, Karabatak M, Demir Y, Tan RS, Acharya UR. Review of Deep Learning-Based Atrial Fibrillation Detection Studies. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:11302. [PMID: 34769819 PMCID: PMC8583162 DOI: 10.3390/ijerph182111302] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Revised: 10/22/2021] [Accepted: 10/24/2021] [Indexed: 02/01/2023]
Abstract
Atrial fibrillation (AF) is a common arrhythmia that can lead to stroke, heart failure, and premature death. Manual screening of AF on electrocardiography (ECG) is time-consuming and prone to errors. To overcome these limitations, computer-aided diagnosis systems are developed using artificial intelligence techniques for automated detection of AF. Various machine learning and deep learning (DL) techniques have been developed for the automated detection of AF. In this review, we focused on the automated AF detection models developed using DL techniques. Twenty-four relevant articles published in international journals were reviewed. DL models based on deep neural network, convolutional neural network (CNN), recurrent neural network, long short-term memory, and hybrid structures were discussed. Our analysis showed that the majority of the studies used CNN models, which yielded the highest detection performance using ECG and heart rate variability signals. Details of the ECG databases used in the studies, performance metrics of the various models deployed, associated advantages and limitations, as well as proposed future work were summarized and discussed. This review paper serves as a useful resource for the researchers interested in developing innovative computer-assisted ECG-based DL approaches for AF detection.
Collapse
Affiliation(s)
- Fatma Murat
- Department of Electrical and Electronics Engineering, Firat University, Elazig 23000, Turkey;
| | - Ferhat Sadak
- Department of Mechanical Engineering, Bartin University, Bartin 74100, Turkey;
| | - Ozal Yildirim
- Department of Software Engineering, Firat University, Elazig 23000, Turkey; (O.Y.); (M.T.); (M.K.)
| | - Muhammed Talo
- Department of Software Engineering, Firat University, Elazig 23000, Turkey; (O.Y.); (M.T.); (M.K.)
| | - Ender Murat
- Department of Cardiology, Gülhane Training and Research Hospital, Ankara 06000, Turkey;
| | - Murat Karabatak
- Department of Software Engineering, Firat University, Elazig 23000, Turkey; (O.Y.); (M.T.); (M.K.)
| | - Yakup Demir
- Department of Electrical and Electronics Engineering, Firat University, Elazig 23000, Turkey;
| | - Ru-San Tan
- Department of Cardiology, National Heart Centre Singapore, Singapore 169609, Singapore;
- Department of Cardiology, Duke-NUS Graduate Medical School, Singapore 169857, Singapore
| | - U. Rajendra Acharya
- Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Singapore 138607, Singapore;
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 41354, Taiwan
- Department of Biomedical Engineering, School of Science and Technology, Singapore University of Social Sciences, Singapore 599494, Singapore
| |
Collapse
|
6
|
Radhakrishnan T, Karhade J, Ghosh SK, Muduli PR, Tripathy RK, Acharya UR. AFCNNet: Automated detection of AF using chirplet transform and deep convolutional bidirectional long short term memory network with ECG signals. Comput Biol Med 2021; 137:104783. [PMID: 34481184 DOI: 10.1016/j.compbiomed.2021.104783] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 08/02/2021] [Accepted: 08/17/2021] [Indexed: 11/16/2022]
Abstract
Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and is characterized by the heart's beating in an uncoordinated manner. In clinical studies, patients often do not have visible symptoms during AF, and hence it is harder to detect this cardiac ailment. Therefore, automated detection of AF using the electrocardiogram (ECG) signals can reduce the risk of stroke, coronary artery disease, and other cardiovascular complications. In this paper, a novel time-frequency domain deep learning-based approach is proposed to detect AF and classify terminating and non-terminating AF episodes using ECG signals. This approach involves evaluating the time-frequency representation (TFR) of ECG signals using the chirplet transform. The two-dimensional (2D) deep convolutional bidirectional long short-term memory (BLSTM) neural network model is used to detect and classify AF episodes using the time-frequency images of ECG signals. The proposed TFR based 2D deep learning approach is evaluated using the ECG signals from three public databases. Our developed approach has obtained an accuracy, sensitivity, and specificity of 99.18% (Confidence interval (CI) as [98.86, 99.49]), 99.17% (CI as [98.85 99.49]), and 99.18% (CI as [98.86 99.49]), respectively, with 10-fold cross-validation (CV) technique to detect AF automatically. The proposed approach also classified terminating and non-terminating AF episodes with an average accuracy of 75.86%. The average accuracy value obtained using the proposed approach is higher than the short-time Fourier transform (STFT), discrete-time continuous wavelet transform (DT-CWT), and Stockwell transform (ST) based time-frequency analysis methods with deep convolutional BLSTM models to detect AF. The proposed approach has better AF detection performance than the existing deep learning-based techniques using ECG signals from the MIT-BIH database.
Collapse
Affiliation(s)
- Tejas Radhakrishnan
- Department of Electrical and Electronics Engineering, BITS-Pilani, Hyderabad Campus, Hyderabad, 500078, India
| | - Jay Karhade
- Department of Electrical and Electronics Engineering, BITS-Pilani, Hyderabad Campus, Hyderabad, 500078, India
| | - S K Ghosh
- Department of Electrical and Electronics Engineering, BITS-Pilani, Hyderabad Campus, Hyderabad, 500078, India
| | - P R Muduli
- Department of Electronics Engineering, Indian Institute of Technology (BHU), Varanasi, Uttar Pradesh, 221005, India
| | - R K Tripathy
- Department of Electrical and Electronics Engineering, BITS-Pilani, Hyderabad Campus, Hyderabad, 500078, India.
| | - U Rajendra Acharya
- Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Singapore; Department of Bioinformatics and Medical Engineering, Asia University, Taichung, Taiwan; Department of Biomedical Engineering, School of Science and Technology, SUSS University, Singapore
| |
Collapse
|
7
|
Lee H, Shin M. Learning Explainable Time-Morphology Patterns for Automatic Arrhythmia Classification from Short Single-Lead ECGs. SENSORS 2021; 21:s21134331. [PMID: 34202805 PMCID: PMC8272104 DOI: 10.3390/s21134331] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 06/17/2021] [Accepted: 06/21/2021] [Indexed: 11/16/2022]
Abstract
Automatic detection of abnormal heart rhythms, including atrial fibrillation (AF), using signals obtained from a single-lead wearable electrocardiogram (ECG) device, is useful for daily cardiac health monitoring. In this study, we propose a novel image-based deep learning framework to classify single-lead ECG recordings of short variable length into several different rhythms associated with arrhythmias. By transforming variable-length 1D ECG signals into fixed-size 2D time-morphology representations and feeding them to the beat-interval-texture convolutional neural network (BIT-CNN) model, we aimed to learn the comprehensible characteristics of beat shape and inter-beat patterns over time for arrhythmia classification. The proposed approach allows feature embedding vectors to provide interpretable time-morphology patterns focused at each step of the learning process. In addition, this method reduces the number of model parameters needed to be trained and aids visual interpretation, while maintaining similar performance to other CNN-based approaches to arrhythmia classification. For experiments, we used the PhysioNet/CinC Challenge 2017 dataset and achieved an overall F1_NAO of 81.75% and F1_NAOP of 76.87%, which are comparable to those of the state-of-the-art methods for variable-length ECGs.
Collapse
|
8
|
Diab A, Boudaoud S, Karlsson B, Marque C. Performance comparison of coupling-evaluation methods in discriminating between pregnancy and labor EHG signals. Comput Biol Med 2021; 132:104308. [PMID: 33711558 DOI: 10.1016/j.compbiomed.2021.104308] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 02/27/2021] [Accepted: 02/27/2021] [Indexed: 01/13/2023]
Abstract
BACKGROUND Recent years have seen an increased interest in electrohysterogram (EHG) signals as a means to evaluate the synchronization of uterine contractions. Several studies have pointed out that the quality of signal processing - and hence the interpretation of measurement results - is affected significantly by the choice of measurement technique and the presence of non-stationary frequency content in EHG signals. To our knowledge, the effect of time variance on the quality of EHG signal processing has never been fully investigated. How best to process EHG signals with the goal of distinguishing labor-induced contractions from their harmless, pre-labor cousins, remains an open question. METHOD Our methodology is based on three pillars. The first consists of a new method for EHG preprocessing in which we apply a second-order Butterworth filter to retain only the EHG fast-wave, low-frequency band (FWL), then use a bivariate piecewise stationary pre-segmentation (bPSP) algorithm to segment the EHG signal into stationary parts. The second pillar addresses the estimation of connectivity and directionality using three methods: nonlinear correlation coefficient (h2), general synchronization (H), and Granger causality (GC). The third pillar is related to signal classification and discrimination between pregnancy and labor using receiver operating curves (ROC) and connectivity and direction maps. For this purpose, we analyze the impact of four factors on data processing efficiency: i) method of connectivity detection, ii) effect of piecewise stationary segmentation preprocessing, iii) retained frequency content and iv) electrode configuration used for EHG recording (bipolar vs. unipolar). RESULTS Our results show that piecewise signal segmentation and filtering considerably improves classification performance and statistical significance for some connectivity methods, in particular the h2. To this end we propose a new approach (detailed below) for h2 called Filtered-Windowed (FW) h2 that better highlights the differences between pregnancy and labor in the connectivity matrix and directionality maps. CONCLUSIONS This is the first comparative study of the effects of multiple processing factors on connectivity measurement efficiency. Our results indicate that appropriate preprocessing can improve the differentiation of pregnancy and labor-induced contraction signals and may lead to innovative applications in the prevention of preterm labor.
Collapse
Affiliation(s)
- Ahmad Diab
- Lebanese University, Faculty of public health, Beirut, Lebanon; Universités de Sorbonne, Université de Technologie de Compiègne, CNRS-UMR 7338 BMBI, 60200, Compiègne, France; Institute of Biomedical and Neural Engineering, Reykjavik University, Reykjavik, Iceland.
| | - Sofiane Boudaoud
- Universités de Sorbonne, Université de Technologie de Compiègne, CNRS-UMR 7338 BMBI, 60200, Compiègne, France.
| | - Brynjar Karlsson
- Institute of Biomedical and Neural Engineering, Reykjavik University, Reykjavik, Iceland.
| | - Catherine Marque
- Universités de Sorbonne, Université de Technologie de Compiègne, CNRS-UMR 7338 BMBI, 60200, Compiègne, France.
| |
Collapse
|
9
|
Effects of Phase Shift Errors in Recurrence Plot for Rotating Machinery Fault Diagnosis. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11020873] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
For fault diagnosis and predictive maintenance of rotating machinery, the phase errors generated by the integration processing of a vibration signal are an essential investigation subject. Phase errors affect the solution of mechanical systems with multiple vibration sources and also the information transmitted through the vibration that is used for fault diagnosis. This work proposes the use of phase plane, recurrence plot (RP), and cross recurrence plot (CRP) to evaluate phase shift error effects on the solution of multiple asynchronous and simple periodic functions, and on the smoothing of a Gaussian peak with white noise. Noisy peaks were smoothed twice with the triangular method and with a different number of points. The analysis of the asynchronous periodic functions and the smoothing indicated that a small phase shift changes the phase plane and the RP pattern. These changes can affect not only the accuracy of machinery fault diagnosis but also prediction for the application of timely maintenance actions.
Collapse
|
10
|
Lei N, Kareem M, Moon SK, Ciaccio EJ, Acharya UR, Faust O. Hybrid Decision Support to Monitor Atrial Fibrillation for Stroke Prevention. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:813. [PMID: 33477887 PMCID: PMC7833442 DOI: 10.3390/ijerph18020813] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 01/08/2021] [Accepted: 01/11/2021] [Indexed: 11/16/2022]
Abstract
In this paper, we discuss hybrid decision support to monitor atrial fibrillation for stroke prevention. Hybrid decision support takes the form of human experts and machine algorithms working cooperatively on a diagnosis. The link to stroke prevention comes from the fact that patients with Atrial Fibrillation (AF) have a fivefold increased stroke risk. Early diagnosis, which leads to adequate AF treatment, can decrease the stroke risk by 66% and thereby prevent stroke. The monitoring service is based on Heart Rate (HR) measurements. The resulting signals are communicated and stored with Internet of Things (IoT) technology. A Deep Learning (DL) algorithm automatically estimates the AF probability. Based on this technology, we can offer four distinct services to healthcare providers: (1) universal access to patient data; (2) automated AF detection and alarm; (3) physician support; and (4) feedback channels. These four services create an environment where physicians can work symbiotically with machine algorithms to establish and communicate a high quality AF diagnosis.
Collapse
Affiliation(s)
- Ningrong Lei
- College of Business, Technology and Engineering, Sheffield Hallam University, Sheffield S1 1WB, UK;
| | - Murtadha Kareem
- Materials & Engineering Research Institute, Sheffield Hallam University, Sheffield S1 1WB, UK;
| | - Seung Ki Moon
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798, Singapore;
| | - Edward J. Ciaccio
- Department of Medicine-Cardiology, Columbia University, New York, NY 10027, USA;
| | - U Rajendra Acharya
- Ngee Ann Polytechnic, Singapore 598269, Singapore;
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 41354, Taiwan
- School of Management and Enterprise, University of Southern Queensland, Toowoomba 4350, Australia
| | - Oliver Faust
- College of Business, Technology and Engineering, Sheffield Hallam University, Sheffield S1 1WB, UK;
| |
Collapse
|
11
|
Faust O, Ciaccio EJ, Acharya UR. A Review of Atrial Fibrillation Detection Methods as a Service. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:E3093. [PMID: 32365521 PMCID: PMC7246533 DOI: 10.3390/ijerph17093093] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 04/19/2020] [Accepted: 04/24/2020] [Indexed: 12/28/2022]
Abstract
Atrial Fibrillation (AF) is a common heart arrhythmia that often goes undetected, and even if it is detected, managing the condition may be challenging. In this paper, we review how the RR interval and Electrocardiogram (ECG) signals, incorporated into a monitoring system, can be useful to track AF events. Were such an automated system to be implemented, it could be used to help manage AF and thereby reduce patient morbidity and mortality. The main impetus behind the idea of developing a service is that a greater data volume analyzed can lead to better patient outcomes. Based on the literature review, which we present herein, we introduce the methods that can be used to detect AF efficiently and automatically via the RR interval and ECG signals. A cardiovascular disease monitoring service that incorporates one or multiple of these detection methods could extend event observation to all times, and could therefore become useful to establish any AF occurrence. The development of an automated and efficient method that monitors AF in real time would likely become a key component for meeting public health goals regarding the reduction of fatalities caused by the disease. Yet, at present, significant technological and regulatory obstacles remain, which prevent the development of any proposed system. Establishment of the scientific foundation for monitoring is important to provide effective service to patients and healthcare professionals.
Collapse
Affiliation(s)
- Oliver Faust
- Department of Engineering and Mathematics, Sheffield Hallam University, Sheffield S1 1WB, UK
| | - Edward J. Ciaccio
- Department of Medicine—Cardiology, Columbia University, New York, NY 10027, USA;
| | - U. Rajendra Acharya
- Ngee Ann Polytechnic, Electronic & Computer Engineering, Singapore 599489, Singapore;
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 41354, Taiwan
| |
Collapse
|
12
|
Ciaccio EJ, Wan EY, Saluja DS, Acharya UR, Peters NS, Garan H. Addressing challenges of quantitative methodologies and event interpretation in the study of atrial fibrillation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2019; 178:113-122. [PMID: 31416540 PMCID: PMC6748794 DOI: 10.1016/j.cmpb.2019.06.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2019] [Revised: 05/21/2019] [Accepted: 06/14/2019] [Indexed: 05/06/2023]
Abstract
Atrial fibrillation (AF) is the commonest arrhythmia, yet the mechanisms of its onset and persistence are incompletely known. Although techniques for quantitative assessment have been investigated, there have been few attempts to integrate this information to advance disease treatment protocols. In this review, key quantitative methods for AF analysis are described, and suggestions are provided for the coordination of the available information, and to develop foci and directions for future research efforts. Quantitative biologists may have an interest in this topic in order to develop machine learning and tools for arrhythmia characterization, but they may perhaps have a minimal background in the clinical methodology and in the types of observed events and mechanistic hypotheses that have thus far been developed. We attempt to address these issues via exploration of the published literature. Although no new data is presented in this review, examples are shown of current lines of investigation, and in particular, how electrogram analysis and whole-chamber quantitative modeling of the left atrium may be useful to characterize fibrillatory patterns of activity, so as to propose avenues for more efficacious acquisition and interpretation of AF data.
Collapse
Affiliation(s)
- Edward J Ciaccio
- Department of Medicine - Division of Cardiology, Columbia University Medical Center, New York, NY, USA; ElectroCardioMaths Programme, Imperial Centre for Cardiac Engineering, Imperial College London, London, UK.
| | - Elaine Y Wan
- Department of Medicine - Division of Cardiology, Columbia University Medical Center, New York, NY, USA
| | - Deepak S Saluja
- Department of Medicine - Division of Cardiology, Columbia University Medical Center, New York, NY, USA
| | - U Rajendra Acharya
- Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Singapore
| | - Nicholas S Peters
- ElectroCardioMaths Programme, Imperial Centre for Cardiac Engineering, Imperial College London, London, UK
| | - Hasan Garan
- Department of Medicine - Division of Cardiology, Columbia University Medical Center, New York, NY, USA
| |
Collapse
|