1
|
Zhdanov DD, Ivin YY, Shishparenok AN, Kraevskiy SV, Kanashenko SL, Agafonova LE, Shumyantseva VV, Gnedenko OV, Pinyaeva AN, Kovpak AA, Ishmukhametov AA, Archakov AI. Perspectives for the creation of a new type of vaccine preparations based on pseudovirus particles using polio vaccine as an example. BIOMEDITSINSKAIA KHIMIIA 2023; 69:253-280. [PMID: 37937429 DOI: 10.18097/pbmc20236905253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2023]
Abstract
Traditional antiviral vaccines are currently created by inactivating the virus chemically, most often using formaldehyde or β-propiolactone. These approaches are not optimal since they negatively affect the safety of the antigenic determinants of the inactivated particles and require additional purification stages. The most promising platforms for creating vaccines are based on pseudoviruses, i.e., viruses that have completely preserved the outer shell (capsid), while losing the ability to reproduce owing to the destruction of the genome. The irradiation of viruses with electron beam is the optimal way to create pseudoviral particles. In this review, with the example of the poliovirus, the main algorithms that can be applied to characterize pseudoviral particles functionally and structurally in the process of creating a vaccine preparation are presented. These algorithms are, namely, the analysis of the degree of genome destruction and coimmunogenicity. The structure of the poliovirus and methods of its inactivation are considered. Methods for assessing residual infectivity and immunogenicity are proposed for the functional characterization of pseudoviruses. Genome integrity analysis approaches, atomic force and electron microscopy, surface plasmon resonance, and bioelectrochemical methods are crucial to structural characterization of the pseudovirus particles.
Collapse
Affiliation(s)
- D D Zhdanov
- Institute of Biomedical Chemistry, Moscow, Russia
| | - Yu Yu Ivin
- Institute of Biomedical Chemistry, Moscow, Russia; Chumakov Federal Scientific Center for Research and Development of Immune-and-Biological Products of Russian Academy of Sciences, Moscow, Russia
| | | | | | | | | | - V V Shumyantseva
- Institute of Biomedical Chemistry, Moscow, Russia; Pirogov Russian National Research Medical University, Moscow, Russia
| | - O V Gnedenko
- Institute of Biomedical Chemistry, Moscow, Russia
| | - A N Pinyaeva
- Institute of Biomedical Chemistry, Moscow, Russia; Chumakov Federal Scientific Center for Research and Development of Immune-and-Biological Products of Russian Academy of Sciences, Moscow, Russia
| | - A A Kovpak
- Institute of Biomedical Chemistry, Moscow, Russia
| | - A A Ishmukhametov
- Chumakov Federal Scientific Center for Research and Development of Immune-and-Biological Products of Russian Academy of Sciences, Moscow, Russia
| | - A I Archakov
- Institute of Biomedical Chemistry, Moscow, Russia; Pirogov Russian National Research Medical University, Moscow, Russia
| |
Collapse
|
2
|
Shi W, Li K, Zhang Y. The Advancement of Nanomaterials for the Detection of Hepatitis B Virus and Hepatitis C Virus. Molecules 2023; 28:7201. [PMID: 37894681 PMCID: PMC10608909 DOI: 10.3390/molecules28207201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 09/07/2023] [Accepted: 09/21/2023] [Indexed: 10/29/2023] Open
Abstract
Viral hepatitis is a global health concern mostly caused by hepatitis B virus (HBV) and hepatitis C virus (HCV). The late diagnosis and delayed treatment of HBV and HCV infections can cause irreversible liver damage and the occurrence of cirrhosis and hepatocellular carcinoma. Detecting the presence and activity of HBV and HCV is the cornerstone of the diagnosis and management of related diseases. However, the traditional method shows limitations. The utilization of nanomaterials has been of great significance in the advancement of virus detection technologies due to their unique mechanical, electrical, and optical properties. Here, we categorized and illustrated the novel approaches used for the diagnosis of HBV and HCV.
Collapse
Affiliation(s)
- Wanting Shi
- Interventional Therapy Center of Liver Disease, Beijing You’An Hospital, Capital Medical University, Beijing 100069, China;
| | - Kang Li
- Biomedical Information Center, Beijing You’An Hospital, Capital Medical University, Beijing 100069, China
| | - Yonghong Zhang
- Interventional Therapy Center of Liver Disease, Beijing You’An Hospital, Capital Medical University, Beijing 100069, China;
| |
Collapse
|
3
|
Curulli A. Functional Nanomaterials Enhancing Electrochemical Biosensors as Smart Tools for Detecting Infectious Viral Diseases. Molecules 2023; 28:molecules28093777. [PMID: 37175186 PMCID: PMC10180161 DOI: 10.3390/molecules28093777] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 04/18/2023] [Accepted: 04/24/2023] [Indexed: 05/15/2023] Open
Abstract
Electrochemical biosensors are known as analytical tools, guaranteeing rapid and on-site results in medical diagnostics, food safety, environmental protection, and life sciences research. Current research focuses on developing sensors for specific targets and addresses challenges to be solved before their commercialization. These challenges typically include the lowering of the limit of detection, the widening of the linear concentration range, the analysis of real samples in a real environment and the comparison with a standard validation method. Nowadays, functional nanomaterials are designed and applied in electrochemical biosensing to support all these challenges. This review will address the integration of functional nanomaterials in the development of electrochemical biosensors for the rapid diagnosis of viral infections, such as COVID-19, middle east respiratory syndrome (MERS), influenza, hepatitis, human immunodeficiency virus (HIV), and dengue, among others. The role and relevance of the nanomaterial, the type of biosensor, and the electrochemical technique adopted will be discussed. Finally, the critical issues in applying laboratory research to the analysis of real samples, future perspectives, and commercialization aspects of electrochemical biosensors for virus detection will be analyzed.
Collapse
Affiliation(s)
- Antonella Curulli
- Consiglio Nazionale delle Ricerche (CNR), Istituto per lo Studio dei Materiali Nanostrutturati (ISMN), 00161 Rome, Italy
| |
Collapse
|
4
|
Sengupta J, Hussain CM. Decadal Journey of CNT-Based Analytical Biosensing Platforms in the Detection of Human Viruses. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:4132. [PMID: 36500755 PMCID: PMC9738197 DOI: 10.3390/nano12234132] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 11/19/2022] [Accepted: 11/21/2022] [Indexed: 06/17/2023]
Abstract
It has been proven that viral infections pose a serious hazard to humans and also affect social health, including morbidity and mental suffering, as illustrated by the COVID-19 pandemic. The early detection and isolation of virally infected people are, thus, required to control the spread of viruses. Due to the outstanding and unparalleled properties of nanomaterials, numerous biosensors were developed for the early detection of viral diseases via sensitive, minimally invasive, and simple procedures. To that aim, viral detection technologies based on carbon nanotubes (CNTs) are being developed as viable alternatives to existing diagnostic approaches. This article summarizes the advancements in CNT-based biosensors since the last decade in the detection of different human viruses, namely, SARS-CoV-2, dengue, influenza, human immunodeficiency virus (HIV), and hepatitis. Finally, the shortcomings and benefits of CNT-based biosensors for the detection of viruses are outlined and discussed.
Collapse
Affiliation(s)
- Joydip Sengupta
- Department of Electronic Science, Jogesh Chandra Chaudhuri College, Kolkata 700033, India
| | - Chaudhery Mustansar Hussain
- Department of Chemistry and Environmental Science, New Jersey Institute of Technology, Newark, NJ 07102, USA
| |
Collapse
|
5
|
Santos LKB, Mendonça PD, Assis LKS, Prudêncio CR, Guedes MIF, Marques ETA, Dutra RF. A Redox-Probe-Free Immunosensor Based on Electrocatalytic Prussian Blue Nanostructured Film One-Step-Prepared for Zika Virus Diagnosis. BIOSENSORS 2022; 12:623. [PMID: 36005020 PMCID: PMC9406047 DOI: 10.3390/bios12080623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/28/2022] [Accepted: 07/29/2022] [Indexed: 06/15/2023]
Abstract
The Zika virus (ZIKV) is a great concern for global health due to its high transmission, including disseminating through blood, saliva, urine, semen and vertical transmission. In some cases, ZIKV has been associated with microcephaly, neurological disorders, and Guillain−Barré syndrome. There is no vaccine, and controlling the disease is a challenge, especially with the co-circulation of the Dengue virus, which causes a severe cross-reaction due to the similarity between the two arboviruses. Considering that electrochemical immunosensors are well-established, sensitive, and practical tools for diagnosis, in this study we developed a sensor platform with intrinsic redox activity that facilitates measurement readouts. Prussian blue (PB) has a great ability to form electrocatalytic surfaces, dispensing redox probe solutions in voltammetric measurements. Herein, PB was incorporated into a chitosan−carbon nanotube hybrid, forming a nanocomposite that was drop-casted on a screen-printed electrode (SPE). The immunosensor detected the envelope protein of ZIKV in a linear range of 0.25 to 1.75 µg/mL (n = 8, p < 0.01), with a 0.20 µg/mL limit of detection. The developed immunosensor represents a new method for electrochemical measurements without additional redox probe solutions, and it is feasible for application in point-of-care diagnosis.
Collapse
Affiliation(s)
- Lorenna K. B. Santos
- Biomedical Engineering Laboratory, Department of Biomedical Engineering, Federal University of Pernambuco, Avenida Professor Moraes Rego 1235, Recife 50670-90, Brazil
| | - Priscila D. Mendonça
- Biomedical Engineering Laboratory, Department of Biomedical Engineering, Federal University of Pernambuco, Avenida Professor Moraes Rego 1235, Recife 50670-90, Brazil
| | - LiLian K. S. Assis
- Biomedical Engineering Laboratory, Department of Biomedical Engineering, Federal University of Pernambuco, Avenida Professor Moraes Rego 1235, Recife 50670-90, Brazil
| | | | | | - Ernesto T. A. Marques
- Department of Infectious Diseases and Microbiology, University of Pittsburgh, Pittsburgh, PA 15261, USA
| | - Rosa Fireman Dutra
- Biomedical Engineering Laboratory, Department of Biomedical Engineering, Federal University of Pernambuco, Avenida Professor Moraes Rego 1235, Recife 50670-90, Brazil
| |
Collapse
|
6
|
Xing G, Wang C, Liu K, Luo B, Hou P, Wang X, Dong H, Wang J, Li A. A probe-free electrochemical immunosensor for methyl jasmonate based on a Cu-MOF–carboxylated graphene oxide platform. RSC Adv 2022; 12:16688-16695. [PMID: 35754916 PMCID: PMC9169702 DOI: 10.1039/d1ra07683c] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 05/16/2022] [Indexed: 11/21/2022] Open
Abstract
A probe-free electrochemical immunosensor for methyl jasmonate has been developed based on a Cu-MOF-carboxylated graphene oxide platform.
Collapse
Affiliation(s)
- Gengqi Xing
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China
- College of Landscape and Ecological Engineering, Hebei University of Engineering, Handan 056038, China
| | - Cheng Wang
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China
| | - Ke Liu
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China
| | - Bin Luo
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China
| | - Peichen Hou
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China
| | - Xiaodong Wang
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China
| | - Hongtu Dong
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China
| | - Jianshu Wang
- College of Landscape and Ecological Engineering, Hebei University of Engineering, Handan 056038, China
| | - Aixue Li
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China
| |
Collapse
|
7
|
Monteil S, Casson AJ, Jones ST. Electronic and electrochemical viral detection for point-of-care use: A systematic review. PLoS One 2021; 16:e0258002. [PMID: 34591907 PMCID: PMC8483417 DOI: 10.1371/journal.pone.0258002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Accepted: 09/15/2021] [Indexed: 12/27/2022] Open
Abstract
Detecting viruses, which have significant impact on health and the economy, is essential for controlling and combating viral infections. In recent years there has been a focus towards simpler and faster detection methods, specifically through the use of electronic-based detection at the point-of-care. Point-of-care sensors play a particularly important role in the detection of viruses. Tests can be performed in the field or in resource limited regions in a simple manner and short time frame, allowing for rapid treatment. Electronic based detection allows for speed and quantitative detection not otherwise possible at the point-of-care. Such approaches are largely based upon voltammetry, electrochemical impedance spectroscopy, field effect transistors, and similar electrical techniques. Here, we systematically review electronic and electrochemical point-of-care sensors for the detection of human viral pathogens. Using the reported limits of detection and assay times we compare approaches both by detection method and by the target analyte of interest. Compared to recent scoping and narrative reviews, this systematic review which follows established best practice for evidence synthesis adds substantial new evidence on 1) performance and 2) limitations, needed for sensor uptake in the clinical arena. 104 relevant studies were identified by conducting a search of current literature using 7 databases, only including original research articles detecting human viruses and reporting a limit of detection. Detection units were converted to nanomolars where possible in order to compare performance across devices. This approach allows us to identify field effect transistors as having the fastest median response time, and as being the most sensitive, some achieving single-molecule detection. In general, we found that antigens are the quickest targets to detect. We also observe however, that reports are highly variable in their chosen metrics of interest. We suggest that this lack of systematisation across studies may be a major bottleneck in sensor development and translation. Where appropriate, we use the findings of the systematic review to give recommendations for best reporting practice.
Collapse
Affiliation(s)
- Solen Monteil
- Department of Materials, School of Natural Sciences, University of Manchester, Manchester, United Kingdom
- The Henry Royce Institute, Manchester, United Kingdom
| | - Alexander J. Casson
- The Henry Royce Institute, Manchester, United Kingdom
- Department of Electrical and Electronic Engineering, School of Engineering, University of Manchester, Manchester, United Kingdom
| | - Samuel T. Jones
- Department of Materials, School of Natural Sciences, University of Manchester, Manchester, United Kingdom
- The Henry Royce Institute, Manchester, United Kingdom
| |
Collapse
|
8
|
Xing G, Luo B, Qin J, Wang X, Hou P, Zhang H, Wang C, Wang J, Li A. A probe-free electrochemical immunosensor for methyl jasmonate based on ferrocene functionalized-carboxylated graphene-multi-walled carbon nanotube nanocomposites. Talanta 2021; 232:122477. [PMID: 34074445 DOI: 10.1016/j.talanta.2021.122477] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 04/21/2021] [Accepted: 04/26/2021] [Indexed: 11/29/2022]
Abstract
Methyl jasmonate (MeJA) is an endogenous plant hormone, which plays an important role in agriculture production. A novel probe-free electrochemical immunosensor was fabricated for detecting of MeJA. Fc, carboxylated graphene (COOH-GR) and carboxylated multi-walled carbon nanotubes (COOH-MWNT) composite was formed and used to fabricate screen-printed electrode (SPE). Fc was used as the electronic medium. COOH-GR and COOH-MWNT were used to improve the conductivity and catalytic activity of the sensor and to immobilize the MeJA antibody. Thus, the immunosensor can be used to detect MeJA without external redox probe solution. The designed sensor can detect MeJA in a wide range of 100 fM-100 μM, and its detection limit is as low as 31.26 fM (S/N = 3). The as-prepared probe-free immunosensor is simple, low cost, and does not need redox probe solutions for measurements, which shows great promise for future application in precision agriculture.
Collapse
Affiliation(s)
- Gengqi Xing
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China; College of Landscape and Ecological Engineering, Hebei University of Engineering, Handan, 056038, China
| | - Bin Luo
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China
| | - Junqing Qin
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China
| | - Xiaodong Wang
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China
| | - Peichen Hou
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China
| | - Han Zhang
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China
| | - Cheng Wang
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China; School of Agricultural Equipment Engineering, Jiangsu University, Zhenjiang, 212013, China
| | - Jianshu Wang
- College of Landscape and Ecological Engineering, Hebei University of Engineering, Handan, 056038, China.
| | - Aixue Li
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China; School of Agricultural Equipment Engineering, Jiangsu University, Zhenjiang, 212013, China.
| |
Collapse
|
9
|
Landim VPA, Silva BVM, Sobral Filho DC, Dutra RF. A Novel Redox‐free Immunosensor Concept Based on Cobalt Phthalocyanine@carbon Nanotubes Pseudocapacitor for Cardiac B‐type Natriuretic Peptide Detection. ELECTROANAL 2021. [DOI: 10.1002/elan.202100177] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Affiliation(s)
- Vicente P. A. Landim
- Biomedical Engineering Laboratory, Department of Biomedical Engineering Federal University of Pernambuco Av. Prof. Moraes Rego, 1235. Recife-PE 50670-901 Brazil
| | - Bárbara V. M. Silva
- Biomedical Engineering Laboratory, Department of Biomedical Engineering Federal University of Pernambuco Av. Prof. Moraes Rego, 1235. Recife-PE 50670-901 Brazil
| | - Dário C. Sobral Filho
- Cardiac Emergency of Pernambuco (PROCAPE)/State University of Pernambuco R. dos Palmares Recife-PE 74970-240 Brazil
| | - Rosa F. Dutra
- Biomedical Engineering Laboratory, Department of Biomedical Engineering Federal University of Pernambuco Av. Prof. Moraes Rego, 1235. Recife-PE 50670-901 Brazil
| |
Collapse
|
10
|
Mendonça PD, Santos LKB, Foguel MV, Rodrigues MAB, Cordeiro MT, Gonçalves LM, Marques ETA, Dutra RF. NS1 glycoprotein detection in serum and urine as an electrochemical screening immunosensor for dengue and Zika virus. Anal Bioanal Chem 2021; 413:4873-4885. [PMID: 34152457 DOI: 10.1007/s00216-021-03449-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 05/21/2021] [Accepted: 05/31/2021] [Indexed: 11/28/2022]
Abstract
The incidence of infection by the dengue virus (DENV) has grown dramatically, reaching 128 countries in tropical and subtropical regions worldwide, with a pattern of hyper-endemicity. DENV is a mosquito-borne disease having four serotypes, one or two circulating in epidemic outbreaks. The diagnosis of DENV is challenging mainly due to the circulation of new viruses with remarkable similarities, such as Zika (ZIKV) that may cause fetal microcephaly. DENV affects 390 million people per year, but these numbers may be higher due to the underreported and misclassified cases. Recently, the NS1 nonstructural protein has been described in serum and urine of DENV and ZIKV patients, suggesting its use as a biomarker for screening since a negative NS1 sample confirms the absence of these infections. Herein, a label-free immunosensor comprising an assembled nanostructured thin film of carbon nanotube-ethylenediamine is described. The advantage of in situ electrosynthesis of polymer film is to allow major control of thickness and conductivity, in addition to designing the reactive groups for functionalization. A quartz crystal microbalance system was used to estimate the thickness of the polymeric film obtained. The anti-NS1 monoclonal antibodies were immobilized to carbon nanotubes by covalent linkage, permitting a high stability during measurements. Analytical responses to NS1 were obtained by differential pulse voltammetry (DPV), showing a linear range from 20 to 800 ng mL-1 and reproducibility of 3.0%, with a limit of detection (LOD) of 6.8 ng mL- 1. This immunosensor was capable of detecting ZIKV and DENV NS1 in spiked urine and real serum in a clinical range.Graphical abstract.
Collapse
Affiliation(s)
- Priscila D Mendonça
- Biomedical Engineering Laboratory, Federal University of Pernambuco, Recife, PE, 50670-901, Brazil
| | - Lorenna K B Santos
- Biomedical Engineering Laboratory, Federal University of Pernambuco, Recife, PE, 50670-901, Brazil
| | - Marcos V Foguel
- Biomedical Engineering Laboratory, Federal University of Pernambuco, Recife, PE, 50670-901, Brazil
| | - Marco A B Rodrigues
- Electronic Department, Federal University of Pernambuco, Recife, PE, 50740-550, Brazil
| | - Marli T Cordeiro
- Department of Virology and Experimental Therapy, Oswaldo Cruz Foundation - FIOCRUZ, Aggeu Magalhães Institute, Recife, PE, 50670-420, Brazil
| | - Luís M Gonçalves
- Institute of Chemistry, University of São Paulo, São Paulo, SP, 5508-000, Brazil
| | - Ernesto T A Marques
- Department of Infectious Diseases and Microbiology, University of Pittsburgh, Center for Vaccine Research, Pittsburgh, PA, 15261, USA
| | - Rosa F Dutra
- Biomedical Engineering Laboratory, Federal University of Pernambuco, Recife, PE, 50670-901, Brazil.
| |
Collapse
|
11
|
A Label and Probe-Free Zika Virus Immunosensor Prussian Blue@carbon Nanotube-Based for Amperometric Detection of the NS2B Protein. BIOSENSORS-BASEL 2021; 11:bios11050157. [PMID: 34065688 PMCID: PMC8156682 DOI: 10.3390/bios11050157] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 05/02/2021] [Accepted: 05/10/2021] [Indexed: 12/14/2022]
Abstract
Zika virus (ZIKV) is a mosquito-borne infection, predominant in tropical and subtropical regions causing international concern due to the ZIKV disease having been associated with congenital disabilities, especially microcephaly and other congenital abnormalities in the fetus and newborns. Development of strategies that minimize the devastating impact by monitoring and preventing ZIKV transmission through sexual intercourse, especially in pregnant women, since no vaccine is yet available for the prevention or treatment, is critically important. ZIKV infection is generally asymptomatic and cross-reactivity with dengue virus (DENV) is a global concern. An innovative screen-printed electrode (SPE) was developed for amperometric detection of the non-structural protein (NS2B) of ZIKV by exploring the intrinsic redox catalytic activity of Prussian blue (PB), incorporated into a carbon nanotube–polypyrrole composite. Thus, this immunosensor has the advantage of electrochemical detection without adding any redox-probe solution (probe-less detection), allowing a point-of-care diagnosis. It was responsive to serum samples of only ZIKV positive patients and non-responsive to negative ZIKV patients, even if the sample was DENV positive, indicating a possible differential diagnosis between them by NS2B. All samples used here were confirmed by CDC protocols, and immunosensor responses were also checked in the supernatant of C6/36 and in Vero cell cultures infected with ZIKV.
Collapse
|
12
|
Recent Advances of Hepatitis B Detection towards Paper-Based Analytical Devices. ScientificWorldJournal 2021; 2021:6643573. [PMID: 33727897 PMCID: PMC7937490 DOI: 10.1155/2021/6643573] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 02/18/2021] [Accepted: 02/19/2021] [Indexed: 02/03/2023] Open
Abstract
Hepatitis B virus (HBV) still remains a major global public health problem. One-half to one-third of the total HBV infected people died due to late detection of HBV. Serological antigen and viral HBV detections can help in the diagnosis, referral, and treatment of HBV. Available methods for HBV detection mostly used bulky instruments. Miniaturization of devices for HBV detection has been started by narrowing down the size of the devices. Several methods have also been proposed to increase the selectivity and sensitivity of the miniaturized methods, such as sandwich recognition of the biomarkers and the use of nano- to micro-sized materials. This review presents recent HBV detections in the last two decades from laboratory-based instruments towards microfluidic paper-based analytical devices (µPADs) for point-of-care testing (POCT) purposes. Early and routine analysis to detect HBV as early as possible could be achieved by POCT, especially for areas with limited access to a central laboratory and/or medical facilities.
Collapse
|
13
|
Brazaca LC, Dos Santos PL, de Oliveira PR, Rocha DP, Stefano JS, Kalinke C, Abarza Muñoz RA, Bonacin JA, Janegitz BC, Carrilho E. Biosensing strategies for the electrochemical detection of viruses and viral diseases - A review. Anal Chim Acta 2021; 1159:338384. [PMID: 33867035 PMCID: PMC9186435 DOI: 10.1016/j.aca.2021.338384] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 03/03/2021] [Accepted: 03/04/2021] [Indexed: 02/06/2023]
Abstract
Viruses are the causing agents for many relevant diseases, including influenza, Ebola, HIV/AIDS, and COVID-19. Its rapid replication and high transmissibility can lead to serious consequences not only to the individual but also to collective health, causing deep economic impacts. In this scenario, diagnosis tools are of significant importance, allowing the rapid, precise, and low-cost testing of a substantial number of individuals. Currently, PCR-based techniques are the gold standard for the diagnosis of viral diseases. Although these allow the diagnosis of different illnesses with high precision, they still present significant drawbacks. Their main disadvantages include long periods for obtaining results and the need for specialized professionals and equipment, requiring the tests to be performed in research centers. In this scenario, biosensors have been presented as promising alternatives for the rapid, precise, low-cost, and on-site diagnosis of viral diseases. This critical review article describes the advancements achieved in the last five years regarding electrochemical biosensors for the diagnosis of viral infections. First, genosensors and aptasensors for the detection of virus and the diagnosis of viral diseases are presented in detail regarding probe immobilization approaches, detection methods (label-free and sandwich), and amplification strategies. Following, immunosensors are highlighted, including many different construction strategies such as label-free, sandwich, competitive, and lateral-flow assays. Then, biosensors for the detection of viral-diseases-related biomarkers are presented and discussed, as well as point of care systems and their advantages when compared to traditional techniques. Last, the difficulties of commercializing electrochemical devices are critically discussed in conjunction with future trends such as lab-on-a-chip and flexible sensors.
Collapse
Affiliation(s)
- Laís Canniatti Brazaca
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, SP, 13566-590, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica-INCTBio, Campinas, SP, 13083-970, Brazil.
| | - Pãmyla Layene Dos Santos
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, SC, 88040-900, Brazil
| | - Paulo Roberto de Oliveira
- Departamento de Ciências Naturais, Matemática e Educação, Universidade Federal de São Carlos, Araras, SP, 13600-970, Brazil
| | - Diego Pessoa Rocha
- Instituto de Química, Universidade Federal de Uberlândia, Uberlândia, MG, 38400-902, Brazil
| | - Jéssica Santos Stefano
- Departamento de Ciências Naturais, Matemática e Educação, Universidade Federal de São Carlos, Araras, SP, 13600-970, Brazil; Instituto de Química, Universidade Federal de Uberlândia, Uberlândia, MG, 38400-902, Brazil
| | - Cristiane Kalinke
- Instituto de Química, Universidade Estadual de Campinas, Campinas, SP, 13083-859, Brazil
| | - Rodrigo Alejandro Abarza Muñoz
- Instituto Nacional de Ciência e Tecnologia de Bioanalítica-INCTBio, Campinas, SP, 13083-970, Brazil; Instituto de Química, Universidade Federal de Uberlândia, Uberlândia, MG, 38400-902, Brazil
| | - Juliano Alves Bonacin
- Instituto de Química, Universidade Estadual de Campinas, Campinas, SP, 13083-859, Brazil
| | - Bruno Campos Janegitz
- Departamento de Ciências Naturais, Matemática e Educação, Universidade Federal de São Carlos, Araras, SP, 13600-970, Brazil.
| | - Emanuel Carrilho
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, SP, 13566-590, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica-INCTBio, Campinas, SP, 13083-970, Brazil.
| |
Collapse
|
14
|
3D-printed electrode as a new platform for electrochemical immunosensors for virus detection. Anal Chim Acta 2020; 1147:30-37. [PMID: 33485583 PMCID: PMC7997732 DOI: 10.1016/j.aca.2020.12.014] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 10/20/2020] [Accepted: 12/07/2020] [Indexed: 11/23/2022]
Abstract
Simple, low-cost, and sensitive new platforms for electrochemical immunosensors for virus detection have been attracted attention due to the recent pandemic caused by a new type of coronavirus (SARS-CoV-2). In the present work, we report for the first time the construction of an immunosensor using a commercial 3D conductive filament of carbon black and polylactic acid (PLA) to detect Hantavirus Araucaria nucleoprotein (Np) as a proof-of-concept. The recognition biomolecule was anchored directly at the filament surface by using N-(3-Dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride and N-Hydroxysuccinimide (EDC/NHS). Conductive and non-conductive composites of PLA were characterized using thermal gravimetric analysis (TGA), revealing around 30% w/w of carbon in the filament. Morphological features of composites were obtained from SEM and TEM measurements. FTIR measurement revealed that crosslinking agents were covalently bonded at the filament surface. Electrochemical techniques such as cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used for the evaluation of each step involved in the construction of the proposed immunosensor. The results showed the potentiality of the device for the quantitative detection of Hantavirus Araucaria nucleoprotein (Np) from 30 μg mL-1 to 240 μg mL-1 with a limit of detection of 22 μg mL-1. Also, the proposed immunosensor was applied with success for virus detection in 100x diluted human serum samples. Therefore, the PLA conductive filament with carbon black is a simple and excellent platform for immunosensing, which offers naturally carboxylic groups able to anchor covalently biomolecules.
Collapse
|
15
|
Ferreira PAB, Araujo MCM, Prado CM, de Lima RA, Rodríguez BAG, Dutra RF. An ultrasensitive Cystatin C renal failure immunosensor based on a PPy/CNT electrochemical capacitor grafted on interdigitated electrode. Colloids Surf B Biointerfaces 2020; 189:110834. [PMID: 32066088 DOI: 10.1016/j.colsurfb.2020.110834] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2019] [Revised: 01/18/2020] [Accepted: 01/29/2020] [Indexed: 12/18/2022]
Abstract
An interdigitated immunosensor for Cystatin C detection based on polypyrrole/carbon nanotube electrochemical capacitor is described. Cystatin C (CysC) is powerful biomarker for early acute renal failure and one predictive for cardiovascular risk, sepsis, cancer and death. Recently, electrochemical immunosensors based on interdigitated electrodes (IDE) have been successfully focused on development of point-of-care testing, due to their miniaturization facilities and higher sensitivity as compared with the screen-printed electrochemical sensing. Herein, a polypyrrole/carbon nanotube nanoyhibrid film was grafted on two gold fingers by electropolymerization obtaining a supercapacitor. Anti-CysC antibodies were immobilized on the IDE by covalent entrapment via ethylenediamine bifunctional agent, followed by glycine blocking in acid and alkaline medium. Under low frequency, capacitive effect of antigen-antibody interaction were observed by double layer capacitance, and analytical responses of this IDE immunosensor to CysC serum were obtained by changes on phase angle a linear range up to 300 ng/mL. The cutoff was calculated for serum samples showing a total reducing of non-specific binding at approximately 28 ng/mL CysC. This immunosensor based on interdigitated electrode (IDE) is a potential tools as portable device,with possibility to use as a practical and rapid test for CysC diagnostic in samples of serum.
Collapse
Affiliation(s)
- Paula A B Ferreira
- Biomedical Engineering Laboratory, Department of Biomedical Engineering, Federal University of Pernambuco, Recife, Brazil
| | - Maria C M Araujo
- Biomedical Engineering Laboratory, Department of Biomedical Engineering, Federal University of Pernambuco, Recife, Brazil
| | - Cecília M Prado
- Biomedical Engineering Laboratory, Department of Biomedical Engineering, Federal University of Pernambuco, Recife, Brazil
| | - Ricardo A de Lima
- Electrical Engineering Department, Pernambuco State University, Recife, Brazil
| | - Blanca A G Rodríguez
- Biomedical Engineering Laboratory, Department of Biomedical Engineering, Federal University of Pernambuco, Recife, Brazil
| | - Rosa F Dutra
- Biomedical Engineering Laboratory, Department of Biomedical Engineering, Federal University of Pernambuco, Recife, Brazil.
| |
Collapse
|
16
|
Trindade EK, Silva BV, Dutra RF. A probeless and label-free electrochemical immunosensor for cystatin C detection based on ferrocene functionalized-graphene platform. Biosens Bioelectron 2019; 138:111311. [DOI: 10.1016/j.bios.2019.05.016] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Revised: 04/23/2019] [Accepted: 05/06/2019] [Indexed: 12/18/2022]
|
17
|
Chen HJ, Chen RLC, Hsieh BC, Hsiao HY, Kung Y, Hou YT, Cheng TJ. Label-free and reagentless capacitive aptasensor for thrombin. Biosens Bioelectron 2019; 131:53-59. [PMID: 30826650 DOI: 10.1016/j.bios.2019.02.025] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 01/10/2019] [Accepted: 02/06/2019] [Indexed: 12/14/2022]
Abstract
This investigation develops a label-free and reagentless aptasensor, based on a capacitive transducer with simple face-to-face electrode pairs. The electrode pairs of the transducer are composed of a gold electrode and an indium tin oxide film with micrometer separation with a double-side polyethylene terephthalate tape. Aptamers and 1-dodecanethiol are modified to form a self-assembled monolayer (SAM) on the gold electrode surfaces, and function as bio-recognition elements and preventers of non-specific protein binding, respectively. Electrochemical characterization results indicate that the SAM also forms an effective insulating layer, which is sufficient for capacitive sensing. The feasibility of the capacitive biosensor is validated using thrombin as a model analyte. The ultra-small value changes of capacitance originating from thrombin binding with the aptamers modified on the biosensor were measured with a home-made capacitance measuring circuit based on switched capacitor (SC) technology. The developed biosensor has detection limits of 1 pM and 10 pM of thrombin in phosphate buffered saline and mimic serum solution, respectively. The linear range for thrombin detection in human serum solution is from 10 pM to 1 μM, with a regression coefficient of 0.98. Additionally, the proposed aptasensor does not have significant levels of non-specific binding of bovine serum albumin and human serum albumin. Accordingly, the combination of SC and SAM bringing capacitive transduction at the forefront of ultrasensitive label-free and reagentless biosensing devices, particularly for point-of-care clinical analysis, which adopts small numbers of biological samples with low analyte concentrations.
Collapse
Affiliation(s)
- Hsin-Ju Chen
- Department of Bio-Industrial Mechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan
| | - Richie L C Chen
- Department of Bio-Industrial Mechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan
| | - Bo-Chuan Hsieh
- Department of Bio-Industrial Mechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan
| | - Hsien-Yi Hsiao
- Department of Bio-Industrial Mechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan
| | - Yi Kung
- Department of Bio-Industrial Mechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan
| | - Yung-Te Hou
- Department of Bio-Industrial Mechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan
| | - Tzong-Jih Cheng
- Department of Bio-Industrial Mechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan; Department of Biomedical Engineering, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan.
| |
Collapse
|