1
|
Mohammadi A, Bianchi L, Korganbayev S, De Landro M, Saccomandi P. Thermomechanical Modeling of Laser Ablation Therapy of Tumors: Sensitivity Analysis and Optimization of Influential Variables. IEEE Trans Biomed Eng 2021; 69:302-313. [PMID: 34181533 DOI: 10.1109/tbme.2021.3092889] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
In cancer treatment, laser ablation is a promising technique used to induce localized thermal damage. Different variables influence the temperature distribution in the tissue and the resulting therapy efficacy; thus, the optimal therapy settings are required for obtaining the desired clinical outcome. In this work, thermomechanical modeling of contactless laser ablation was implemented to analyze the sensitivity of independent variables on the optimal treatment conditions. The Finite Element Method was utilized to solve the governing equations, i.e., the bioheat, mechanical deformation, and the Navier-Stokes equations. Validation of the model was evaluated by comparing experimental and simulated temperatures, which indicated high accuracy for estimating temperature. In particular, the results showed that the model is capable of estimating temperature with a good correlation factor (R=0.98) and low Mean Absolute Error (3.9 C). A sensitivity analysis based on laser irradiation time, power, beam distribution, and the blood vessel depth on temperature distribution and fraction of necrotic tissue was performed. Based on the most significant variables i.e., laser irradiation time and power, an optimization process was performed. This resulted into an indication of the optimal therapy settings for achieving maximum procedure efficiency i.e., the required fraction of necrotic tissue within the target volume, constituted by tumor and safety margins around it.
Collapse
|
2
|
Mohammadi A, Bianchi L, Asadi S, Saccomandi P. Measurement of Ex Vivo Liver, Brain and Pancreas Thermal Properties as Function of Temperature. SENSORS (BASEL, SWITZERLAND) 2021; 21:4236. [PMID: 34205567 PMCID: PMC8235733 DOI: 10.3390/s21124236] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 06/04/2021] [Accepted: 06/17/2021] [Indexed: 12/11/2022]
Abstract
The ability to predict heat transfer during hyperthermal and ablative techniques for cancer treatment relies on understanding the thermal properties of biological tissue. In this work, the thermal properties of ex vivo liver, pancreas and brain tissues are reported as a function of temperature. The thermal diffusivity, thermal conductivity and volumetric heat capacity of these tissues were measured in the temperature range from 22 to around 97 °C. Concerning the pancreas, a phase change occurred around 45 °C; therefore, its thermal properties were investigated only until this temperature. Results indicate that the thermal properties of the liver and brain have a non-linear relationship with temperature in the investigated range. In these tissues, the thermal properties were almost constant until 60 to 70 °C and then gradually changed until 92 °C. In particular, the thermal conductivity increased by 100% for the brain and 60% for the liver up to 92 °C, while thermal diffusivity increased by 90% and 40%, respectively. However, the heat capacity did not significantly change in this temperature range. The thermal conductivity and thermal diffusivity were dramatically increased from 92 to 97 °C, which seems to be due to water vaporization and state transition in the tissues. Moreover, the measurement uncertainty, determined at each temperature, increased after 92 °C. In the temperature range of 22 to 45 °C, the thermal properties of pancreatic tissue did not change significantly, in accordance with the results for the brain and liver. For the three tissues, the best fit curves are provided with regression analysis based on measured data to predict the tissue thermal behavior. These curves describe the temperature dependency of tissue thermal properties in a temperature range relevant for hyperthermia and ablation treatments and may help in constructing more accurate models of bioheat transfer for optimization and pre-planning of thermal procedures.
Collapse
Affiliation(s)
| | | | | | - Paola Saccomandi
- Department of Mechanical Engineering, Politecnico di Milano, 20156 Milan, Italy; (A.M.); (L.B.); (S.A.)
| |
Collapse
|
3
|
Kumar S, Ram R, Sarkar A, DasGupta S, Chakraborty S. Rapid determination of erythrocyte sedimentation rate (ESR) by an electrically driven blood droplet biosensor. BIOMICROFLUIDICS 2020; 14:064108. [PMID: 33312329 PMCID: PMC7710385 DOI: 10.1063/5.0026332] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2020] [Accepted: 11/13/2020] [Indexed: 05/10/2023]
Abstract
In healthcare practice, the sedimentation rate of red blood cells (erythrocytes) is a widely used clinical parameter for screening of several ailments such as stroke, infectious diseases, and malignancy. In a traditional pathological setting, the total time taken for evaluating this parameter varies typically from 1 to 2 h. Furthermore, the volume of human blood to be drawn for each test, following a gold standard laboratory technique (alternatively known as the Westergren method), varies from 4 to 5 ml. Circumventing the above constraints, here we propose a rapid (∼1 min) and highly energy efficient method for the simultaneous determination of hematocrit and erythrocyte sedimentation rate (ESR) on a microfluidic chip, deploying electrically driven spreading of a tiny drop of blood sample (∼8 μl). Our unique approach estimates these parameters by correlating the same with the time taken by the droplet to spread over a given radius, reproducing the results from more elaborate laboratory settings to a satisfactory extent. Our novel methodology is equally applicable for determining higher ranges of ESR such as high concentration of bilirubin and samples corresponding to patients with anemia and patients with some severe inflammation. Furthermore, the minimal fabrication steps involved in the process, along with the rapidity and inexpensiveness of the test, render the suitability of the strategy in extreme point-of-care settings.
Collapse
Affiliation(s)
- Sumit Kumar
- Advanced Technology Development Centre, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721302, India
| | - Rishi Ram
- Department of Mechanical Engineering, Indian Institute of Technology (BHU), Varanasi, Uttar Pradesh 221005, India
| | | | | | - Suman Chakraborty
- Author to whom correspondence should be addressed:. Telephone: +913222282990. Fax: +913222282278
| |
Collapse
|
4
|
Dey P, Saha SK, Chakraborty S. Surface Nanostructure-Wettability Coupling Leads to Unique Topological Evolution Dictating Water Transport over Nanometer Scales. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:8111-8122. [PMID: 32589848 DOI: 10.1021/acs.langmuir.0c00955] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Surface nanostructure, either designed or generated as an artifact of the fabrication procedure, is known to influence interfacial phenomena intriguingly. While surface roughness-wettability coupling over nanometer scales has been addressed to some extent, the explicit interplay of hydrodynamics and confinement toward dictating the underlying characteristics for practically relevant material interfaces remains unexplored. Here, we bring out unique roles of surface nanostructures toward altering flow of water in a copper nanochannel, by capturing an exclusive interplay of confinement, roughness, wettability and flow dynamics. Toward this, non-equilibrium molecular dynamics (NEMD) simulations are performed to examine the effect of nanoscale triangular roughness. The width and height of the triangular microgroove are varied along with different driving forces at the channel inlet, and the results are compared with those corresponding to smooth-walled nanochannels. We also unveil the nontrivial characteristics of the interfacial topology as a consequence of spontaneous phase separation at the fluid-solid interface. For a constant driving force, we show that the interface may exhibit concave or convex topology, depending on the nanogroove geometry. Our results provide new vistas on how designed nanoscale roughness structures can be harnessed toward controlling the transport of water in a practically engineered nanosystem, as demanded by the specific application on hand.
Collapse
Affiliation(s)
- Prasenjit Dey
- Department of Mechanical Engineering, National Institute of Technology Goa, Ponda 403401, India
| | - Sandip K Saha
- Department of Mechanical Engineering, Indian Institute of Technology Bombay, Mumbai 400076, India
| | - Suman Chakraborty
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| |
Collapse
|
5
|
Roy R, Mukherjee S, Lakkaraju R, Chakraborty S. Streaming potential in bio-mimetic microvessels mediated by capillary glycocalyx. Microvasc Res 2020; 132:104039. [PMID: 32645366 DOI: 10.1016/j.mvr.2020.104039] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 05/29/2020] [Accepted: 07/01/2020] [Indexed: 11/16/2022]
Abstract
Implantable medical devices and biosensors are pivotal in revolutionizing the field of medical technology by opening new dimensions in the field of disease detection and cure. These devices need to harness a biocompatible and physiologically sustainable safe power source instead of relying on external stimuli, overcoming the constraints on their applicability in-vivo. Here, by appealing to the interplay of electromechanics and hydrodynamics in physiologically relevant microvessels, we bring out the role of charged endothelial glycocalyx layer (EGL) towards establishing a streaming potential across physiological fluidic conduits. We account for the complex rheology of blood-mimicking fluid by appealing to Newtonian fluid model representing the blood plasma and a viscoelastic fluid model representing the whole blood. We model the EGL as a poroelastic layer with volumetric charge distribution. Our results reveal that for physiologically relevant micro-flows, the streaming potential induced is typically of the order of 0.1 V/mm, which may turn out to be substantial towards energizing biosensors and implantable medical devices whose power requirements are typically in the range of micro to milliwatts. We also bring out the specific implications of the relevant physiological parameters towards establishment of the streaming potential, with a vision of augmenting the same within plausible functional limits. We further unveil that the dependence of streaming potential on EGL thickness might be one of the key aspects in unlocking the mystery behind the angiogenesis pattern. Our results may open up novel bio-sensing and actuating possibilities in medical diagnostics as well as may provide a possible alternative regarding the development of physiologically safe and biocompatible power sources within the human body.
Collapse
Affiliation(s)
- Rahul Roy
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Siddhartha Mukherjee
- Advanced Technology Development Center, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Rajaram Lakkaraju
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Suman Chakraborty
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India; Advanced Technology Development Center, Indian Institute of Technology Kharagpur, Kharagpur 721302, India.
| |
Collapse
|
6
|
Karan P, Das SS, Mukherjee R, Chakraborty J, Chakraborty S. Flow and deformation characteristics of a flexible microfluidic channel with axial gradients in wall elasticity. SOFT MATTER 2020; 16:5777-5786. [PMID: 32531014 DOI: 10.1039/d0sm00333f] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Axial gradients in wall elasticity may have significant implications in the deformation and flow characteristics of a narrow fluidic conduit, bearing far-reaching consequences in physiology and bio-engineering. Here, we present a theoretical and experimental framework for fluid-structure interactions in microfluidic channels with axial gradients in wall elasticity, in an effort to arrive at a potential conceptual foundation for in vitro study of mirovascular physiology. Towards this, we bring out the static deformation and steady flow characteristics of a circular microchannel made of polydimethylsiloxane (PDMS) bulk, considering imposed gradients in the substrate elasticity. In particular, we study two kinds of elasticity variations - a uniformly soft (or hard) channel with a central strip that is hard (or soft), and, increasing elasticity along the length of the channel. The former kind yields a centrally constricted (or expanded) deformed profile in response to the flow. The latter kind leads to increasingly bulged channel radius from inlet to outlet in response to flow. We also formulate an analytical model capturing the essential physics of the underlying elastohydrodynamic interactions. The theoretical predictions match favourably with the experimental observations and are also in line with reported results on stenosis in mice. The present framework, thus, holds the potential for acting as a fundamental design basis towards developing in vitro models for micro-circulation, capable of capturing exclusive artefacts of healthy and diseased conditions.
Collapse
Affiliation(s)
- Pratyaksh Karan
- Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, 721302, India.
| | - Sankha Shuvra Das
- Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, 721302, India.
| | - Rabibrata Mukherjee
- Department of Chemical Engineering, Indian Institute of Technology, Kharagpur, 721302, India
| | - Jeevanjyoti Chakraborty
- Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, 721302, India.
| | - Suman Chakraborty
- Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, 721302, India.
| |
Collapse
|
7
|
Bandyopadhyay S, Khare S, Bhandaru N, Mukherjee R, Chakraborty S. High Temperature Durability of Oleoplaned Slippery Copper Surfaces. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:4135-4143. [PMID: 32216354 DOI: 10.1021/acs.langmuir.9b03940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Slippery surfaces, inspired by the functionality of trapping interfaces of specialized leaves of pitcher plants, have been widely used in self-cleaning, anti-icing, antifrost, and self-healing surfaces. They can be fabricated on metallic surfaces as well, presenting a more durable and low-maintenance anticorrosive surface on metals. However, the lack of studies on the durability of these slippery surfaces at high temperature prohibits their practical deployment in real industrial applications where thermal effects are critical and high temperature conditions are inevitable. We present here a unique fabrication technique of a copper-based oleoplaned slippery surface that has been tested for high temperature durability under repeated thermal cycles. Their slipperiness at high temperatures has also been tested in the absence of the Leidenfrost effect. Our findings suggest that these new substrates can be used for fabricating low maintenance surfaces for high temperature applications or even where the surface undergoes repeated thermal cycles like heat exchanger pipes, utensils, engine casings, and outdoor metallic structures.
Collapse
Affiliation(s)
- Saumyadwip Bandyopadhyay
- Advanced Technology Development Centre, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Shreshth Khare
- Department of Chemical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, West Bengal, India
| | - Nandini Bhandaru
- Department of Chemical Engineering, Birla Institute of Technology and Science Pilani, Hyderabad Campus, 500 078 Telangana, India
| | - Rabibrata Mukherjee
- Department of Chemical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, West Bengal, India
| | - Suman Chakraborty
- Advanced Technology Development Centre, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, West Bengal, India
| |
Collapse
|
8
|
Agarwal R, Sarkar A, Chakraborty S. Interplay of Coriolis effect with rheology results in unique blood dynamics on a compact disc. Analyst 2019; 144:3782-3789. [PMID: 31094378 DOI: 10.1039/c9an00645a] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We investigate the influence of rotational forces on blood dynamics in a microfluidic device. The special confluence of Coriolis force and blood rheology is brought forth by analyzing the flow at different hematocrit (volume fraction of red blood cells) levels and rotational speeds. We further study the effects of channel layout and alignment with regard to the axis of rotation to understand this intricate interplay. We provide a sound basis for efficient designing of a lab on a compact disc (lab on CD) platform by harnessing the effects of Coriolis force at relatively much lower rotational speeds, in sharp contrast with the reported findings where Coriolis effects have been considered to be effective only for exceptionally high rotational speeds. Our results show that over certain intermediate regimes of rotational speeds, the flow profiles for different hematocrit levels are noticeably different. This, in turn, could be harnessed as a possible diagnostic signature of the hematocrit (or equivalently, packed cell volume) level, without necessitating the deployment of chemical consumables, in an energy efficient paradigm.
Collapse
Affiliation(s)
- Rahul Agarwal
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur - 721302, India.
| | | | | |
Collapse
|
9
|
Paul A, Paul A. Computational study of photo-thermal ablation of large blood vessel embedded tumor using localized injection of gold nanoshells. J Therm Biol 2018; 78:329-342. [DOI: 10.1016/j.jtherbio.2018.10.021] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Revised: 10/21/2018] [Accepted: 10/27/2018] [Indexed: 10/27/2022]
|
10
|
Enhanced EPR directed and Imaging guided Photothermal Therapy using Vitamin E Modified Toco-Photoxil. Sci Rep 2018; 8:16673. [PMID: 30420735 PMCID: PMC6232175 DOI: 10.1038/s41598-018-34898-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Accepted: 10/10/2018] [Indexed: 11/16/2022] Open
Abstract
Herein we report synthesis, characterization and preclinical applications of a novel hybrid nanomaterial Toco-Photoxil developed using vitamin E modified gold coated poly (lactic-co-glycolic acid) nanoshells incorporating Pgp inhibitor d-α-tocopheryl polyethylene glycol 1000 succinate (TPGS) as a highly inert and disintegrable photothermal therapy (PTT) agent. Toco-Photoxil is highly biocompatible, physiologically stable PTT material with an average diameter of 130 nm that shows good passive accumulation (2.3% ID) in solid tumors when delivered systemically. In comparison to its surface modified counterparts such as IR780-Toco-Photoxil, FA-Toco-Photoxil or FA-IR780-Toco-Photoxil accumulation are merely ~0.3% ID, ~0.025% ID and ~0.005% ID in folate receptor (FR) negative and positive tumor model. Further, Toco-Photoxil variants are prepared by tuning the material absorbance either at 750 nm (narrow) or 915 nm (broad) to study optimal therapeutic efficacy in terms of peak broadness and nanomaterial’s concentration. Our findings suggest that Toco-Photoxil tuned at 750 nm absorbance is more efficient (P = 0.0097) in preclinical setting. Toco-Photoxil shows complete passiveness in critical biocompatibility test and reasonable body clearance. High tumor specific accumulation from systemic circulation, strong photothermal conversion and a very safe material property in body physiology makes Toco-Photoxil a superior and powerful PTT agent, which may pave its way for fast track clinical trial in future.
Collapse
|
11
|
Srivastava A. Modelling of Laser-Induced Heating of Tissues for Therapeutic Applications. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES INDIA SECTION A-PHYSICAL SCIENCES 2018. [DOI: 10.1007/s40010-018-0520-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
12
|
Shurrab K, Kochaji N, Bachir W. Development of Temperature Distribution and Light Propagation Model in Biological Tissue Irradiated by 980 nm Laser Diode and Using COMSOL Simulation. J Lasers Med Sci 2017; 8:118-122. [PMID: 29123630 DOI: 10.15171/jlms.2017.21] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Introduction: The purpose of this project is to develop a mathematical model to investigate light distribution and study effective parameters such as laser power and irradiated time to get the optimal laser dosage to control hyperthermia. This study is expected to have a positive impact and a better simulation on laser treatment planning of biological tissues. Moreover, it may enable us to replace animal tests with the results of a COMSOL predictive model. Methods: We used in this work COMSOL5 model to simulate the light diffusion and bio-heat equation of the mouse tissue when irradiated by 980 nm laser diode and the effect of different parameters (laser power, and irradiated time) on the surrounding tissue of the tumor treatment in order to prevent damage from excess heat Results: The model was applied to study light propagation and several parameters (laser power, irradiated time) and their impact on light-heat distribution within the tumor in the mouse back tissue The best result is at laser power 0.5 W and time irradiation 0.5 seconds in order to get the maximum temperature hyperthermia at 52°C. Conclusion: The goal of this study is to simulate a mouse model to control excess heating of tissue and reduce the number of animals in experimental research to get the best laser parameters that was safe for use in living animals and in human subjects.
Collapse
Affiliation(s)
- Kawthar Shurrab
- Higher Institute for Laser Research and Applications, Damascus University, Syria
| | - Nabil Kochaji
- Dean of Faculty of Dentistry, Al-Sham University, Damascus, Syria
| | - Wesam Bachir
- Higher Institute for Laser Research and Applications, Damascus University, Syria
| |
Collapse
|
13
|
Martin NA, Falder S. A review of the evidence for threshold of burn injury. Burns 2017; 43:1624-1639. [PMID: 28536038 DOI: 10.1016/j.burns.2017.04.003] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Revised: 03/05/2017] [Accepted: 04/02/2017] [Indexed: 01/24/2023]
Abstract
INTRODUCTION Burn injury is common and depth is one measure of severity. Although the depth of burn injury is determined by many factors, the relationship between the temperature of the injurious agent and exposure duration, known as the time-temperature relationship, is widely accepted as one of the cornerstones of burn research. Moritz and Henriques first proposed this relationship in 1947 and their seminal work has been cited extensively. However, over the years, readers have misinterpreted their findings and incorporated misleading information about the time-temperature relationship into a wide range of industrial standards, burn prevention literature and medicolegal opinion. AIM The purpose of this paper is to present a critical review of the evidence that relates temperature and time to cell death and the depth of burn injury. These concepts are used by researchers, burn prevention strategists, burn care teams and child protection professionals involved in ascertaining how the mechanism of burning relates to the injury pattern and whether the injury is consistent with the history. REVIEW METHODS This review explores the robustness of the currently available evidence. The paper summarises the research from burn damage experimental work as well as bioheat transfer models and discusses the merits and limitations of these approaches. REVIEW FINDINGS There is broad agreement between in vitro and in vivo studies for superficial burns. There is clear evidence that the perception of pain in adult human skin occurs just above 43°C. When the basal layer of the epidermis reaches 44°C, burn injury occurs. For superficial dermal burns, the rate of tissue damage increases logarithmically with a linear increase in temperature. Beyond 70°C, rate of damage is so rapid that interpretation can be difficult. Depth of injury is also influenced by skin thickness, blood flow and cooling after injury. There is less clinical evidence for a time-temperature relationship for deep or subdermal burns. Bioheat transfer models are useful in research and becoming increasingly sophisticated but currently have limited practical use. Time-temperature relationships have not been established for burns in children's skin, although standards for domestic hot water suggest that the maximum temperature should be revised downward by 3-4°C to provide adequate burn protection for children. CONCLUSION Time-temperature relationships established for pain and superficial dermal burns in adult human skin have an extensive experimental modeling basis and reasonable clinical validation. However, time-temperature relationships for subdermal burns, full thickness burns and burn injury in children have limited clinical validation, being extrapolated from other data, and should be used with caution, particularly if presented during expert evidence.
Collapse
Affiliation(s)
- N A Martin
- St. Andrews Centre for Burns and Plastic Surgery, Broomfield Hospital, Chelmsford, Essex CM1 7ET, UK.
| | - S Falder
- Department of Burns and Plastic Surgery, Alder Hey Children's NHS Foundation Trust, Liverpool L12 2AP, UK.
| |
Collapse
|
14
|
Numerical study of non-Fourier heat conduction in a biolayer spherical living tissue during hyperthermia. J Therm Biol 2016; 62:181-188. [DOI: 10.1016/j.jtherbio.2016.06.019] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2015] [Accepted: 06/29/2016] [Indexed: 11/22/2022]
|
15
|
Yang YC, Lee HL, Chang WJ, Chen WL. An inverse problem in estimating the laser irradiance and thermal damage in laser-irradiated biological tissue with a dual-phase-lag model. Comput Methods Biomech Biomed Engin 2016; 20:446-456. [PMID: 27707009 DOI: 10.1080/10255842.2016.1243664] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
The aim of this study is to solve an inverse heat conduction problem to estimate the unknown time-dependent laser irradiance and thermal damage in laser-irradiated biological tissue from the temperature measurements taken within the tissue. The dual-phase-lag model is considered in the formulation of heat conduction equation. The inverse algorithm used in the study is based on the conjugate gradient method and the discrepancy principle. The effect of measurement errors and measurement locations on the estimation accuracy is also investigated. Two different examples of laser irradiance are discussed. Results show that the unknown laser irradiance and thermal damage can be predicted precisely by using the present approach for the test cases considered in this study.
Collapse
Affiliation(s)
- Yu-Ching Yang
- a Clean Energy Center, Department of Mechanical Engineering , Kun Shan University , Tainan , Taiwan, ROC
| | - Haw-Long Lee
- a Clean Energy Center, Department of Mechanical Engineering , Kun Shan University , Tainan , Taiwan, ROC
| | - Win-Jin Chang
- a Clean Energy Center, Department of Mechanical Engineering , Kun Shan University , Tainan , Taiwan, ROC
| | - Wen-Lih Chen
- b Department of Aeronautics and Astronautics , National Cheng Kung University , Tainan , Taiwan, ROC
| |
Collapse
|
16
|
Nourhashemi M, Mahmoudzadeh M, Wallois F. Thermal impact of near-infrared laser in advanced noninvasive optical brain imaging. NEUROPHOTONICS 2016; 3:015001. [PMID: 27115020 PMCID: PMC4802390 DOI: 10.1117/1.nph.3.1.015001] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2015] [Accepted: 12/03/2015] [Indexed: 05/04/2023]
Abstract
The propagation of laser light in human tissues is an important issue in functional optical imaging. We modeled the thermal effect of different laser powers with various spot sizes and different head tissue characteristics on neonatal and adult quasirealistic head models. The photothermal effect of near-infrared laser (800 nm) was investigated by numerical simulation using finite-element analysis. Our results demonstrate that the maximum temperature increase on the brain for laser irradiance between 0.127 (1 mW) and [Formula: see text] (100 mW) at a 1 mm spot size, ranged from 0.0025°C to 0.26°C and from 0.03°C to 2.85°C at depths of 15.9 and 4.9 mm in the adult and neonatal brain, respectively. Due to the shorter distance of the head layers from the neonatal head surface, the maximum temperature increase was higher in the neonatal brain than in the adult brain. Our results also show that, at constant power, spot size changes had a lesser heating effect on deeper tissues. While the constraints for safe laser irradiation to the brain are dictated by skin safety, these results can be useful to optimize laser parameters for a variety of laser applications in the brain. Moreover, combining simulation and adequate in vitro experiments could help to develop more effective optical imaging to avoid possible tissue damage.
Collapse
Affiliation(s)
- Mina Nourhashemi
- Université de Picardie, INSERM U 1105, GRAMFC, CHU Sud, rue René Laennec, 80054 Amiens Cedex 1, France
| | - Mahdi Mahmoudzadeh
- Université de Picardie, INSERM U 1105, GRAMFC, CHU Sud, rue René Laennec, 80054 Amiens Cedex 1, France
| | - Fabrice Wallois
- Université de Picardie, INSERM U 1105, GRAMFC, CHU Sud, rue René Laennec, 80054 Amiens Cedex 1, France
- Address all correspondence to: Fabrice Wallois, E-mail:
| |
Collapse
|
17
|
Paul A, Narasimhan A, Kahlen FJ, Das SK. Temperature evolution in tissues embedded with large blood vessels during photo-thermal heating. J Therm Biol 2014; 41:77-87. [PMID: 24679976 DOI: 10.1016/j.jtherbio.2014.02.010] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2013] [Revised: 12/24/2013] [Accepted: 02/05/2014] [Indexed: 11/25/2022]
Abstract
During laser-assisted photo-thermal therapy, the temperature of the heated tissue region must rise to the therapeutic value (e.g., 43°C) for complete ablation of the target cells. Large blood vessels (larger than 500 micron in diameter) at or near the irradiated tissues have a considerable impact on the transient temperature distribution in the tissue. In this study, the cooling effects of large blood vessels on temperature distribution in tissues during laser irradiation are predicted using finite element based simulation. A uniform flow is assumed at the entrance and three-dimensional conjugate heat transfer equations in the tissue region and the blood region are simultaneously solved for different vascular models. A volumetric heat source term based on Beer-Lambert law is introduced into the energy equation to account for laser heating. The heating pattern is taken to depend on the absorption and scattering coefficients of the tissue medium. Experiments are also conducted on tissue mimics in the presence and absence of simulated blood vessels to validate the numerical model. The coupled heat transfer between thermally significant blood vessels and their surrounding tissue for three different tissue-vascular networks are analyzed keeping the laser irradiation constant. A surface temperature map is obtained for different vascular models and for the bare tissue (without blood vessels). The transient temperature distribution is seen to differ according to the nature of the vascular network, blood vessel size, flow rate, laser spot size, laser power and tissue blood perfusion rate. The simulations suggest that the blood flow through large blood vessels in the vicinity of the photothermally heated tissue can lead to inefficient heating of the target.
Collapse
Affiliation(s)
- Anup Paul
- Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering, IIT Madras, Chennai, Tamilnadu 600036, India
| | - Arunn Narasimhan
- Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering, IIT Madras, Chennai, Tamilnadu 600036, India
| | - Franz J Kahlen
- Department of Mechanical Engineering, University of Cape Town, Rondebosch 7701, Republic of South Africa
| | - Sarit K Das
- Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering, IIT Madras, Chennai, Tamilnadu 600036, India.
| |
Collapse
|
18
|
Chua K. Computer simulations on multiprobe freezing of irregularly shaped tumors. Comput Biol Med 2011; 41:493-505. [DOI: 10.1016/j.compbiomed.2011.04.015] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2010] [Revised: 04/14/2011] [Accepted: 04/28/2011] [Indexed: 01/08/2023]
|
19
|
Medeiros JL, Nicolau RA, Nicola EMD, dos Santos JN, Pinheiro ALB. Healing of surgical wounds made with lambda970-nm diode laser associated or not with laser phototherapy (lambda655 nm) or polarized light (lambda400-2000 nm). Photomed Laser Surg 2010; 28:489-96. [PMID: 19857050 DOI: 10.1089/pho.2009.2592] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVE The aim of this study was to analyze the effect of two phototherapies, laser and polarized light, on diode laser (970lambda nm) wounds. BACKGROUND DATA Lasers have been used in surgery, and some wavelengths may cause thermal damage to the tissue and affect healing. Several studies have shown that some wavelengths are effective in improving healing. Coherent and noncoherent light have been successfully used on the modulation of biological phenomena of several origins. ANIMALS AND METHODS Thirty-one Wistar rats were divided into 3 groups (GI to GIII). A 20-mm x 2-mm wound was created on the dorsum of each animal with a diode laser (Sirolaser, Sirona, Bensheim, Germany). Group GI acted as control. On GII, laser light (lambda655 nm, 30 mW, phi approximately 3 mm, 12 J/cm(2)) was used and on GIII illumination with polarized light (lambda400-2000 nm, 40 mW, phi approximately 5.5 cm, 12 J/cm(2)) was used, every other day (GII) or daily (GIII) for 7 days. The animals were killed at 0, 7, and 14 days after surgery. Specimens were taken, routinely processed, stained and imunnomarked [HE (hematoxylin-eosin), sirius red, alpha-smooth muscle actin (SMA)], and underwent histological analysis. RESULTS GII showed better response at day 14 when re-epithelialization was in a more advanced stage. The number of myofibroblasts was significantly different over the healing time (7 to 14 days); this number was smaller than that observed on G1. On GIII at day 7, the number of myofibroblasts was significantly higher than for GII. At day 14, a more pronounced deposition of collagen matrix was also seen, and inflammation was discrete and more advanced for GIII. CONCLUSION The results of the present study showed that the effect of the use of laser light was more evident at early stages of healing and that the use of polarized light improved the resolution of the inflammatory reaction, increased the deposition of collagen, increased the number of myofibroblasts, and quickened re-epithelialization during the experimental time.
Collapse
Affiliation(s)
- Juliana L Medeiros
- Center of Biophotonics, School of Dentistry, Federal University of Bahia, Salvador, Bahia, Brazil
| | | | | | | | | |
Collapse
|
20
|
Fanjul-Vélez F, Romanov OG, Arce-Diego JL. Efficient 3D numerical approach for temperature prediction in laser irradiated biological tissues. Comput Biol Med 2009; 39:810-7. [DOI: 10.1016/j.compbiomed.2009.06.009] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2008] [Revised: 02/04/2009] [Accepted: 06/25/2009] [Indexed: 10/20/2022]
|
21
|
Datsko BY, Gafiychuk VV, Lubashevsky IA, Priezzhev AV. Self-localization of laser induced tumour coagulation limited by heat diffusion through active tissue. J Med Eng Technol 2006; 30:390-6. [PMID: 17060167 DOI: 10.1080/03091900500467340] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
We analyse necrosis growth due to thermal coagulation induced by laser light absorption and limited by heat diffusion into the surrounding live tissue. The tissue is assumed to contain a tumour in the undamaged tissue where the blood perfusion rate does not change during the action. By contrast, normal tissue responds strongly to an increase in the tissue temperature and the blood perfusion rate can grow by tenfold. We study in detail necrosis formation under conditions typical of a real course of thermal therapy treatment. The duration of the treatment is about 5 minutes when a necrosis domain of about 1 cm or above is formed. In particular, if the tumour size is sufficiently large, i.e. it exceeds 1 cm, and the tissue response is not too delayed, i.e. the delay time does not exceed 1 min, then there are conditions under which the relative volume of the damaged normal tissue is small in comparison with the tumour volume after the tumour is totally coagulated.
Collapse
Affiliation(s)
- B Y Datsko
- Institute for Applied Problems in Mechanics and Mathematics, National Academy of Sciences of Ukraine, Naukova Street 3b, 79053, Lviv, Ukraine.
| | | | | | | |
Collapse
|