1
|
Anjos FCQS, Marcelino AC, Espejo-Arce X, Pereira PDC, Barbosa PF, Juliato CT, Bahamondes L. Clinical Assessment of 3 Intrauterine Devices in Adolescent Girls: A Randomized Clinical Trial. J Pediatr Adolesc Gynecol 2024; 37:165-170. [PMID: 38113970 DOI: 10.1016/j.jpag.2023.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Revised: 11/29/2023] [Accepted: 12/12/2023] [Indexed: 12/21/2023]
Abstract
STUDY OBJECTIVE To assess clinical performance, bleeding pattern, dysmenorrhea, and satisfaction up to 1 year after placement of 3 types of intrauterine devices (IUDs) (TCu380A, levonorgestrel 52 mg, and levonorgestrel 19.5 mg) in adolescents METHODS: The study was a randomized trial with 318 adolescents allocated to the 3 IUDs. We assessed reasons for removal, continuation, menstrual patterns, dysmenorrhea, and satisfaction. RESULTS Participants aged (mean ± SD) 17.9 ± 1.4 years, with 80.8% being nulligravidae. After 1 year, 265 (83.3%) continued using the IUD; however, the continuation rate of TCu380A (75.4 ± 4.2) was lower than that of both the levonorgestrel 52-mg (88.6 ± 3.1) and 19.5-mg IUDs (86.8 ± 3.3), and bleeding/pain and expulsion were the main reasons for removal of the TCu380A IUD. The duration of menstruation was longer among the TCu380A IUD users (6.0 ± 2.0 days) than those using the levonorgestrel 52 mg (2.5 ± 3.9) and 19.5 mg (3.2 ± 3.2) devices, P < .001. Amenorrhea was reported by 49.5% and 37.8% users of the levonorgestrel 52-mg and 19.5-mg devices, respectively, P < .001. Dysmenorrhea was reported in 68.5% of all participants at the baseline; this was 67.9% of the TCu380A group and 33.3% and 36.0% of the levonorgestrel 52-mg and 19.5-mg IUD groups, respectively, P < .001. Satisfaction ranged from 80.7% in the TCu380A group to 97.8% in the levonorgestrel 52-mg group (P = .03). CONCLUSION The 3 IUDs are suitable for adolescents, with high contraceptive efficacies and rates of continuation within 1 year of use and high degrees of satisfaction. Users of the hormonal IUDs reported lower expulsion rates, more favorable menstrual patterns, and less dysmenorrhea compared with the TCu380A IUD.
Collapse
Affiliation(s)
- Fabiana C Q S Anjos
- Department of Obstetrics and Gynecology, University of Gurupi, Faculty of Medical Sciences, Gurupi, TO, Brazil
| | - Ana C Marcelino
- Department of Obstetrics and Gynecology, University of Campinas, Faculty of Medical Sciences, Campinas, SP, Brazil
| | - Ximena Espejo-Arce
- Department of Obstetrics and Gynecology, University of Campinas, Faculty of Medical Sciences, Campinas, SP, Brazil
| | - Paula da C Pereira
- Department of Obstetrics and Gynecology, University of Campinas, Faculty of Medical Sciences, Campinas, SP, Brazil
| | - Priscila F Barbosa
- Department of Obstetrics and Gynecology, University of Gurupi, Faculty of Medical Sciences, Gurupi, TO, Brazil
| | - Cassia T Juliato
- Department of Obstetrics and Gynecology, University of Campinas, Faculty of Medical Sciences, Campinas, SP, Brazil
| | - Luis Bahamondes
- Department of Obstetrics and Gynecology, University of Campinas, Faculty of Medical Sciences, Campinas, SP, Brazil.
| |
Collapse
|
2
|
Jiang J, Bian S, Li S, Wang S. Risk factors for intrauterine device embedment in postmenopausal women: an analysis of 731 participants undergoing hysteroscopy. Menopause 2023; 30:717-722. [PMID: 37162346 PMCID: PMC10309103 DOI: 10.1097/gme.0000000000002191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2023] [Revised: 03/10/2023] [Indexed: 05/11/2023]
Abstract
OBJECTIVE This study aimed to explore the risk factors for intrauterine device (IUD) embedment in postmenopausal women. METHODS A total of 731 women who underwent hysteroscopy for IUD removal from January 2019 to December 2021 were included in the trial, of whom 301 were diagnosed with IUD embedment (embedded group) and 430 had a normal IUD location (control group). The following data were collected from electronic medical records: demographic traits, ultrasound findings, IUD shapes, uterine features, and hysteroscopy findings. Bivariate contingency analysis and multiple logistic regression were performed to identify the significant independent variables that affect IUD embedment. RESULTS Prior IUD removal failure (14.3% vs 5.1%; adjusted odds ratio [aOR], 3.29; 95% CI, 1.90-5.71) and V-shaped IUD (18.9% vs 10.7%; aOR, 2.05; 95% CI, 1.33-3.16) were risk factors that were independently linked with IUD embedment. Uterine volume (22.7 [20.9-24.5] cm 3 vs 27.9 [24.8-30.9] cm 3 ; aOR, 0.99; 95% CI, 0.982-0.999) was negatively linked with IUD embedment. There were no differences in age, parity, menopause length, years with an IUD in situ, uterine position, or abortion times between the two groups. There were no differences in existing leiomyoma, prior cervical LEEP (loop electrosurgical excision procedure), or myomectomy between the two groups. CONCLUSIONS Prior IUD removal failure, V-shaped IUD, and a smaller uterine volume were risk factors for IUD embedment in menopausal women.
Collapse
|
3
|
Long-Acting Reversible Contraception. Obstet Gynecol 2022; 140:883-897. [DOI: 10.1097/aog.0000000000004967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Accepted: 06/09/2022] [Indexed: 11/15/2022]
|
4
|
Stifani BM, Madden T, Micks E, Moayedi G, Tarleton J, Benson LS. Society of Family Planning Clinical Recommendations: Contraceptive Care in the Context of Pandemic Response. Contraception 2022; 113:1-12. [PMID: 35594989 PMCID: PMC9113767 DOI: 10.1016/j.contraception.2022.05.006] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 05/09/2022] [Accepted: 05/11/2022] [Indexed: 12/16/2022]
Abstract
The coronavirus disease 2019 (COVID-19) pandemic has posed a burden to healthcare systems around the world and has changed the way people access health services, including contraception. This document sets forth guidance from the Society of Family Planning for providing contraceptive care in the context of the COVID-19 pandemic, including when access to healthcare is restricted due to pandemic response. It also outlines the role of telehealth for providing contraceptive care beyond the pandemic. Clinicians can use synchronous telemedicine visits and other forms of telehealth to provide many aspects of contraceptive care. Both audio-video and audio-only visits are acceptable forms of telemedicine. Access to permanent contraception should be maintained, especially in the postpartum period. Combined hormonal contraceptive (CHC) users who have asymptomatic or mild COVID-19 infection may continue their contraceptive method, while those admitted to the hospital with severe infection should suspend CHC use until they are clinically recovered. CHC users who take Paxlovid for mild-moderate COVID-19 infection can consider a back-up contraceptive method for the duration of therapy, but clinically relevant drug interactions are unlikely. Future research should examine contraceptive outcomes in people who receive care via telemedicine; and access to telemedicine among historically excluded populations such as adolescents, people of color, people of low socioeconomic status, disabled people, or people who do not speak English as a primary language.
Collapse
Affiliation(s)
- Bianca M. Stifani
- New York Medical College, Valhalla, NY, USA,Corresponding Author: Bianca M. Stifani, 19 Bradhurst Ave Suite 2700S, Hawthorne, NY, USA
| | - Tessa Madden
- Washington University School of Medicine, St Louis, MO, USA
| | | | | | | | | |
Collapse
|
5
|
Grandi G, Di Vinci P, Sgandurra A, Feliciello L, Monari F, Facchinetti F. Contraception During Perimenopause: Practical Guidance. Int J Womens Health 2022; 14:913-929. [PMID: 35866143 PMCID: PMC9296102 DOI: 10.2147/ijwh.s288070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Accepted: 07/07/2022] [Indexed: 11/23/2022] Open
Abstract
Climacteric is by no means in itself a contraindication to safe contraception. On the contrary, there are several conditions related to the perimenopause that could benefit from the use of modern contraceptives, mainly hormonal, with the goals of avoiding unintended pregnancies and giving further possible benefits beyond contraception (menstrual cycle control, a reduction of vasomotor symptoms and menstrual migraines, a protection against bone loss, a positive oncological risk/benefit balance). This narrative review aims to provide practical guidance on their possible use in this particular life stage, both short- and long-acting reversible contraceptives, and to assist clinicians for women transitioning from contraception to their menopausal years, including the possible initiation of postmenopausal hormone therapy. Comprehensive contraceptive counselling is an essential aspect of the overall health and wellbeing of women and should be addressed with each such patient irrespective of age.
Collapse
Affiliation(s)
- Giovanni Grandi
- Department of Medical and Surgical Sciences for Mother, Child and Adult, University of Modena and Reggio Emilia, Azienda Ospedaliero Universitaria Policlinico, Modena, 41124, Italy
| | - Pierluigi Di Vinci
- International Doctorate School in Clinical and Experimental Medicine, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, 41124, Italy
| | - Alice Sgandurra
- Department of Medical and Surgical Sciences for Mother, Child and Adult, University of Modena and Reggio Emilia, Azienda Ospedaliero Universitaria Policlinico, Modena, 41124, Italy
| | - Lia Feliciello
- Department of Medical and Surgical Sciences for Mother, Child and Adult, University of Modena and Reggio Emilia, Azienda Ospedaliero Universitaria Policlinico, Modena, 41124, Italy
| | - Francesca Monari
- Department of Medical and Surgical Sciences for Mother, Child and Adult, University of Modena and Reggio Emilia, Azienda Ospedaliero Universitaria Policlinico, Modena, 41124, Italy
| | - Fabio Facchinetti
- Department of Medical and Surgical Sciences for Mother, Child and Adult, University of Modena and Reggio Emilia, Azienda Ospedaliero Universitaria Policlinico, Modena, 41124, Italy
| |
Collapse
|
6
|
Dethier D, Qasba N, Kaneshiro B. Society of Family Planning Clinical Recommendation: Extended Use of Long Acting Reversible Contraception. Contraception 2022; 113:13-18. [PMID: 35716806 DOI: 10.1016/j.contraception.2022.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 06/06/2022] [Accepted: 06/08/2022] [Indexed: 11/03/2022]
Abstract
In this clinical recommendation, we review the evidence supporting the use of the copper intrauterine device, levonorgestrel intrauterine devices and etonogestrel subdermal implant beyond the Food and Drug Administration approved duration of use for contraception (extended use). Clinicians should discuss effectiveness as well as other clinical considerations with patients to allow them to make contraceptive decisions that support their reproductive goals and clinical needs. Extended use of long acting reversible contraception may be a safe, effective and desirable option for many patients.
Collapse
Affiliation(s)
- Divya Dethier
- Department of Obstetrics, Gynecology, and Women's Health, University of Hawai`i, John A. Burns School of Medicine, 1319 Punahou Street #824, Honolulu, HI, 96826.
| | - Neena Qasba
- Department of Obstetrics and Gynecology, University of Massachusetts Chan Medical School - Baystate, 759 Chestnut Street, Springfield, MA 01199, USA
| | - Bliss Kaneshiro
- Department of Obstetrics, Gynecology, and Women's Health, University of Hawai`i, John A. Burns School of Medicine, 1319 Punahou Street #824, Honolulu, HI, 96826
| |
Collapse
|
7
|
Abstract
PURPOSE OF REVIEW The COVID-19 pandemic has highlighted existing healthcare disparities worldwide and has challenged access to family planning (FP) services. RECENT FINDINGS Research has identified ways in which government regulations and healthcare programs have inhibited or increased access to FP services, as well as how the pandemic has changed individuals' sexual and reproductive health behaviors and intentions. SUMMARY The pandemic has had both positive and negative effects on access to FP services. Innovations in various delivery services, extended use of contraception, telehealth for medication abortion, and a no-test medication abortion protocol have decreased the need for in-person visits and improved access to FP services.
Collapse
Affiliation(s)
- Taylor Stanton
- Department of Obstetrics & Gynecology, Stanford University, Palo Alto, California, USA
| | - Deborah Bateson
- Family Planning NSW, Faculty of Medicine and Health, Discipline of Obstetrics, Gynaecology and Neonatology, University of Sydney, Sydney, Australia
| |
Collapse
|
8
|
Filho ESF, Machado RB. Contraceptive counseling during the pandemic: practical guidelines. REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRÍCIA 2021; 43:579-584. [PMID: 34461669 PMCID: PMC10302448 DOI: 10.1055/s-0041-1735185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
9
|
Laporte M, Metelus S, Ali M, Bahamondes L. Major differences in the characteristics of users of the copper intrauterine device or levonorgestrel intrauterine system at a clinic in Campinas, Brazil. Int J Gynaecol Obstet 2021; 156:240-246. [PMID: 33872406 DOI: 10.1002/ijgo.13716] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 03/26/2021] [Accepted: 04/16/2021] [Indexed: 11/11/2022]
Abstract
OBJECTIVE To compare the sociodemographic characteristics of users of the copper intrauterine device (Cu-IUD) and the levonorgestrel intrauterine system (LNG-IUS) at a family planning clinic in Campinas, SP, Brazil. METHODS A retrospective audit study was conducted to analyze the characteristics of new users of IUDs at the clinic of the Department of Obstetrics and Gynecology, University of Campinas. Data covered insertions performed between 1979 and 2006 when only the Cu-IUD was offered at the clinic, and between 2007 and 2019 when the LNG-IUS was also offered, both free of charge to women. Logistic regression analysis was performed. RESULTS There were 31 385 insertions. Cu-IUD: n = 17 156 (1979-2006) and n = 2013 (2007-2019); LNG-IUS n = 12 216 (2007-2019). Up to 2006, Cu-IUD users were less likely to be nulligravidas, more likely to be younger than 40 years of age, and with fewer years of schooling. Following introduction of LNG-IUS, the sociodemographic characteristics of users presented major changes over time. Comparing the period 1979-2006 with 2007-2019, new users of the LNG-IUS were more likely to be older than 40 years of age, with fewer years of completed schooling, and to be nulligravidas. CONCLUSION Major changes in sociodemographic characteristics of users were noted according to preference over time. Introduction of the LNG-IUS presents a major opportunity to increase IUD use.
Collapse
Affiliation(s)
- Montas Laporte
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, Brazil
| | - Sherly Metelus
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, Brazil
| | - Moazzam Ali
- Department of Sexual and Reproductive Health and Research, World Health Organization, Geneva, Switzerland
| | - Luis Bahamondes
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, Brazil
| |
Collapse
|
10
|
Bahamondes MV, Bahamondes L. Intrauterine device use is safe among nulligravidas and adolescent girls. Acta Obstet Gynecol Scand 2021; 100:641-648. [PMID: 33483956 DOI: 10.1111/aogs.14097] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Revised: 01/18/2021] [Accepted: 01/19/2021] [Indexed: 10/22/2022]
Abstract
The use of intrauterine devices (IUDs), including the copper-bearing device and the levonorgestrel intrauterine system (LNG-IUS), is safe among nulligravidas and adolescent girls. However, several misconceptions limit their use in clinical practice; health-care providers are hesitant to prescribe IUDs, and several myths associated with their usage in nulligravidas and adolescents exist among both providers and women themselves. The high rates of unplanned pregnancies (which in many settings constitute a public health issue, primarily among adolescent females) can be attributed at least partially to lack of awareness and limited use of highly effective contraceptives such as IUDs. In this review, we discuss the role of non-hormonal and hormonal IUDs as effective contraceptives in nulligravidas and adolescent girls. We present a literature review of data that highlight contraceptive efficacy, side effects (including reasons for discontinuation), and continuation rates with the method. We searched the PubMed/MEDLINE, Cochrane Library, Embase, and Scopus databases for all articles published in English between January 1990 through September 2020. A large body of evidence confirmed the effectiveness of IUD/IUS, independent of age and parity. Studies showed a high expulsion rate among adolescents but not among nulligravidas. Additionally, bleeding patterns among adolescents and nulligravidas were similar to those observed among adults and parous women. The high early removal rates observed in adolescents were attributable to bleeding and/or pain, which indicate that compared with adults, adolescents are less likely to accept IUD-induced side effects. IUD placement is an excellent strategy to avoid the high rates of unplanned pregnancies in adolescents and nulligravidas. IUDs are more effective than short-acting reversible contraceptives with failure rates that are equivalent to those observed with permanent contraception. However, few long-term studies have investigated this category of women to definitively establish the role of IUD/IUS as effective means of contraception.
Collapse
Affiliation(s)
- M Valeria Bahamondes
- Latin American Center of Perinatology, Women's Health and Reproduction (CLAP/SMR), Pan American Health Organization/World Health Organization, Montevideo, Uruguay
| | - Luis Bahamondes
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas (UNICAMP), Campinas, SP, Brazil
| |
Collapse
|
11
|
Laporte M, Becerra A, Castro L, Veiga N, Espejo-Arce X, Bahamondes L. Evaluation of clinical performance when intrauterine devices are inserted by different categories of healthcare professional. Int J Gynaecol Obstet 2020; 152:196-201. [PMID: 32981045 DOI: 10.1002/ijgo.13396] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 07/02/2020] [Accepted: 09/22/2020] [Indexed: 12/14/2022]
Abstract
OBJECTIVE We evaluated clinical performance when the TCu380A intrauterine device (IUD) and the levonorgestrel (LNG) 52-mg intrauterine system (IUS) were inserted by different categories of healthcare professionals. METHODS A retrospective study was conducted at the University of Campinas, Brazil. The medical records were reviewed of all women in whom an IUD was inserted between January 1980 and December 2018, with data for at least 1 year, and for whom information on the healthcare provider who inserted the device was available. RESULTS Overall, 19 132 (76.9%) IUD and 5733 (23.1%) LNG-IUS insertions were included, with residents/interns performing 13 853 (55.8%), nurses 7024 (28.2%), and physicians 3988 (16.0%). Removals for pregnancy and infection were significantly higher when physicians inserted the device, while removals for bleeding/pain and other medical reasons were more common when nurses performed the insertion. Expulsion and removals for personal reasons were similar for all three categories. CONCLUSION Clinical outcomes were similar regardless of whether trained nurses, residents/interns, or physicians inserted the device, and were irrespective of users' age and parity. These results could stimulate other healthcare services, particularly in regions where there is a shortage of physicians, to invest in training nurses to perform insertions of IUDs.
Collapse
Affiliation(s)
- Montas Laporte
- Department of Obstetrics and Gynecology, University of Campinas Faculty of Medical Sciences, Campinas, SP, Brazil
| | - Alejandra Becerra
- Department of Obstetrics and Gynecology, University of Campinas Faculty of Medical Sciences, Campinas, SP, Brazil
| | - Lester Castro
- Department of Obstetrics and Gynecology, University of Campinas Faculty of Medical Sciences, Campinas, SP, Brazil
| | - Nelio Veiga
- Department of Obstetrics and Gynecology, University of Campinas Faculty of Medical Sciences, Campinas, SP, Brazil
| | - Ximena Espejo-Arce
- Department of Obstetrics and Gynecology, University of Campinas Faculty of Medical Sciences, Campinas, SP, Brazil
| | - Luis Bahamondes
- Department of Obstetrics and Gynecology, University of Campinas Faculty of Medical Sciences, Campinas, SP, Brazil
| |
Collapse
|
12
|
Ti AJ, Roe AH, Whitehouse KC, Smith RA, Gaffield ME, Curtis KM. Effectiveness and safety of extending intrauterine device duration: a systematic review. Am J Obstet Gynecol 2020; 223:24-35.e3. [PMID: 31954154 DOI: 10.1016/j.ajog.2020.01.014] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Revised: 12/05/2019] [Accepted: 01/09/2020] [Indexed: 10/25/2022]
Abstract
OBJECTIVE To systematically review the literature to determine if extended use of intrauterine devices, including the copper or levonorgestrel intrauterine device, beyond approved durations is effective and safe for preventing pregnancy. STUDY DESIGN We searched PubMed, Embase, Cumulative Index to Nursing and Allied Health Literature, and Global Index Medicus from inception through June 2019. We considered primary studies of women using the T380A copper or currently available levonorgestrel intrauterine devices past their approved duration (extended use). The primary outcome was pregnancy. Safety outcomes included adverse events and side effects that led to discontinuation. We abstracted study data into evidence tables and assessed study quality as related to the risk of bias, precision, and external validity. For each intrauterine device type, we calculated a pooled pregnancy rate during the first 2 years of extended use using the Poisson inverse variance method. RESULTS Of 4068 studies identified by our search, 4 good-to-poor-quality studies of the 52 mg levonorgestrel intrauterine device (approved for 5 years), with a total of 2098 women starting extended use, and 2 good-to-fair-quality studies of the T380A copper intrauterine device (approved for 10 years), with 245 women starting extended use, met inclusion criteria. For the levonorgestrel intrauterine device, the pooled pregnancy rate was 0.02 per 100 person-years (95% confidence interval, 0.00-0.45) in year 6, 0.03 per 100 person-years (95% confidence interval, 0.00-0.71) in year 7, and 0.02 per 100 person-years (95% confidence interval, 0.00-0.29) in years 6 and 7 combined. During this same time, annual rates of adverse events or discontinuation owing to side effects ranged from 0 to 3.7 per 100 participants. For the copper intrauterine device, the pooled pregnancy rate for years 11 and 12 was 0.0 per 100 person-years (95% confidence interval, 0.0-0.8), and annual rates of adverse events and discontinuation owing to side effects during extended use ranged from 0 to 4.6 per 100 participants. CONCLUSION The available evidence suggests that rates of pregnancy, adverse events, and discontinuation owing to side effects during the first 2 years of extended use of the 52 mg levonorgestrel intrauterine device and the T380A copper intrauterine device are low and comparable to rates during approved duration of use. Data were limited in quantity and quality, and may not be generalizable to all intrauterine device users.
Collapse
|
13
|
Ferreira-Filho ES, de Melo NR, Sorpreso ICE, Bahamondes L, Simões RDS, Soares-Júnior JM, Baracat EC. Contraception and reproductive planning during the COVID-19 pandemic. Expert Rev Clin Pharmacol 2020; 13:615-622. [DOI: 10.1080/17512433.2020.1782738] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Affiliation(s)
- Edson Santos Ferreira-Filho
- Gynecology Division, Hospital Das Clinicas HCFMUSP, Faculdade De Medicina, Universidade De Sao Paulo, Sao Paulo, Brazil
| | - Nilson Roberto de Melo
- Gynecology Division, Hospital Das Clinicas HCFMUSP, Faculdade De Medicina, Universidade De Sao Paulo, Sao Paulo, Brazil
| | | | - Luis Bahamondes
- Family Planning Clinic, Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas (Unicamp), Campinas, Brazil
| | - Ricardo Dos Santos Simões
- Gynecology Division, Hospital Das Clinicas HCFMUSP, Faculdade De Medicina, Universidade De Sao Paulo, Sao Paulo, Brazil
| | - José Maria Soares-Júnior
- Gynecology Division, Hospital Das Clinicas HCFMUSP, Faculdade De Medicina, Universidade De Sao Paulo, Sao Paulo, Brazil
| | - Edmund Chada Baracat
- Gynecology Division, Hospital Das Clinicas HCFMUSP, Faculdade De Medicina, Universidade De Sao Paulo, Sao Paulo, Brazil
| |
Collapse
|
14
|
Long-acting reversible contraceptive (LARCs) methods. Best Pract Res Clin Obstet Gynaecol 2019; 66:28-40. [PMID: 32014434 DOI: 10.1016/j.bpobgyn.2019.12.002] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 12/04/2019] [Accepted: 12/10/2019] [Indexed: 02/06/2023]
Abstract
Unplanned pregnancy (UP) is a public health problem, which affects millions of women worldwide. Providing long-acting reversible contraceptive (LARC) methods is an excellent strategy to avoid or at least reduce UP, because the effectiveness of these methods is higher than other methods, and is indeed comparable to that of permanent contraception. As the initial introduction of the inert plastic intrauterine device (IUD) and of the six-rod implant, pharmaceutical companies have introduced a copper IUD (Cu-IUD), different models of levonorgestrel-releasing intrauterine system (LNG IUS), and one and two-rod implants, which certainly improved women's LARC options. The main characteristic of LARCs is that they provide high contraceptive effectiveness with a single intervention, and that they can be used for a long time. Emerging evidence from the last few years has demonstrated that it is possible to extend the use of the 52 mg LNG IUS and of the etonogestrel-implant beyond five- and three years, respectively, which adds new value to these LARCs.
Collapse
|
15
|
Black A, Guilbert E. Consensus canadien sur la contraception (partie 3 de 4): chapitre 7 - Contraception intra-utérine. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2019; 41 Suppl 1:S1-S23. [DOI: 10.1016/j.jogc.2019.02.124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
16
|
Abstract
To reduce the rate of unintended pregnancies, patients should select a contraceptive option that fits their needs and lifestyle. Long-acting reversible contraceptives (LARCs) are a relatively safe and effective option. This article outlines the characteristics of available LARCs and identifies the appropriate method for specific patient populations.
Collapse
|
17
|
Lambert M, Begon E, Hocké C. [Contraception for women after 40: CNGOF Contraception Guidelines]. GYNECOLOGIE, OBSTETRIQUE, FERTILITE & SENOLOGIE 2018; 46:865-872. [PMID: 30424983 DOI: 10.1016/j.gofs.2018.10.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Indexed: 06/09/2023]
Abstract
INTRODUCTION Choosing contraception for women over 40 can be sometimes difficult but it is crucial since fertility and pregnancy's risks still exist. It requires a thorough evaluation of the situation, in order to identify any vascular and metabolic risk factors, along with the uterine and mammary benign pathologies already diagnosed. OBJECTIVE The objective of this review was to elaborate some guidelines for clinical practice regarding contraception's prescription for women over 40. METHODS A systematic review of the French and English existing literature was conducted. Pubmed and the Cochrane library were used to identify studies about contraception for perimenopausal women. International guidelines published by scientific societies were also reviewed (RCOG, FSRH, ESHRE, ACOG, WHO, HAS). RESULTS No contraceptive methods are contraindicated on the sole basis of age alone. However, because age is a risk factor for vascular and metabolic diseases, combined hormonal contraception and DMPA should not be prescribed at first intention. Copper IUD and progestin-only contraceptives (pill, implant, intrauterine device) should primarily be considered, since they offer good efficacy with lower risks. CONCLUSIONS Contraception for women over 40 should not be put aside. Long acting reversible contraception and progestin-only pill have to be prescribed as first-ine. Contraception is no longer needed for women over 50 who use non-hormonal contraception, after a 12 month-amenorrhea. Patients treated with combined hormonal contraception must stop using it over 50. Measuring hormonal levels while using hormonal contraception is not recommended. An hormonal-contraception-free interval must be considered, while using barrier contraception method. If an ovarian activity persists, a non-hormonal contraception or progestin-only contraception (except for DMPA) should be (re-)established.
Collapse
Affiliation(s)
- M Lambert
- Service de gynécologie et de médecine de la reproduction, centre Aliénor d'Aquitaine, CHU de Bordeaux, place Amélie Raba-Léon, 33076 Bordeaux cedex, France.
| | - E Begon
- Service de gynécologie et de médecine de la reproduction, centre Aliénor d'Aquitaine, CHU de Bordeaux, place Amélie Raba-Léon, 33076 Bordeaux cedex, France
| | - C Hocké
- Service de gynécologie et de médecine de la reproduction, centre Aliénor d'Aquitaine, CHU de Bordeaux, place Amélie Raba-Léon, 33076 Bordeaux cedex, France
| |
Collapse
|
18
|
Vidal F, Paret L, Linet T, Tanguy le Gac Y, Guerby P. [Intrauterine contraception: CNGOF Contraception Guidelines]. ACTA ACUST UNITED AC 2018; 46:806-822. [PMID: 30429071 DOI: 10.1016/j.gofs.2018.10.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To provide national clinical guidelines focusing on intrauterine contraception. METHODS A systematic review of available literature was performed using Pubmed and Cochrane libraries. American, British and Canadian guidelines were considered as well. RESULTS Intrauterine contraception (IUC) displays a wide panel of indications, including adolescents, nulliparous, patients living with HIV before AIDS (Grade B) and women with history of ectopic pregnancy (Grade C). Cervical cancer screening should not be modified in women with IUC (Grade B). Bimanual examination and cervix inspection are mandatory before device insertion (Grade B). Patients should not systematically undergo screening for sexually transmitted infections (STI) before device insertion (Grade B). Screening for STI should be preferably done before insertion but it can be performed at the time of device insertion in asymptomatic women (Grade B). Routine antibiotic prophylaxis and premedication are not recommended before insertion (Grade A). A follow-up visit may be offered several weeks after insertion (Professional consensus). Routine pelvic ultrasound examination in not recommended after device insertion (Grade B). In patients with IUC, unscheduled bleeding, when persistent or associated with pelvic pain, requires further investigation to rule out complication (Professional agreement). Suspected uterine perforation warrants radiological workup to locate the device (Professional consensus). Laparoscopic approach should be preferred for elective removal of intrauterine device from abdominal cavity (Professional consensus). In case of accidental pregnancy with intrauterine device in situ, ectopic pregnancy should be excluded (Grade B). In case of viable and desired intrauterine pregnancy, intrauterine device removal is recommended if the strings are reachable (Grade C). Detection of Actinomyces-like organisms on pap smear in asymptomatic patients with intrauterine contraception does not require further intervention (Grade B). Immediate removal of intrauterine device is not recommended in case of STI or pelvic inflammatory disease (Grade B). Device removal should be considered in the absence of clinical improvement after 48 to 72 hours of appropriate treatment (Grade B). CONCLUSION Intrauterine contraception is a long-acting and reversible contraception method displaying great efficacy and high continuation rate. In contrast, complication rate is low. It should thus be offered to both nulliparous and multiparous women.
Collapse
Affiliation(s)
- F Vidal
- Pôle Femme Mère Couple, hôpital Paule-de-Viguier, CHU Purpan, 330, avenue de Grande-Bretagne, 31059 Toulouse, France; Université Toulouse III, 118, route de Narbonne, 31062 Toulouse, France.
| | - L Paret
- Pôle Femme Mère Couple, hôpital Paule-de-Viguier, CHU Purpan, 330, avenue de Grande-Bretagne, 31059 Toulouse, France; Université Toulouse III, 118, route de Narbonne, 31062 Toulouse, France
| | - T Linet
- Service de gynécologie-obstétrique, centre hospitalier Loire-Vendée-Océan, 85300 Challans, France
| | - Y Tanguy le Gac
- Pôle Femme Mère Couple, hôpital Paule-de-Viguier, CHU Purpan, 330, avenue de Grande-Bretagne, 31059 Toulouse, France
| | - P Guerby
- Pôle Femme Mère Couple, hôpital Paule-de-Viguier, CHU Purpan, 330, avenue de Grande-Bretagne, 31059 Toulouse, France; Université Toulouse III, 118, route de Narbonne, 31062 Toulouse, France
| |
Collapse
|
19
|
Hu S, Wang Y, Ke D, Zhou F, Cheng G, Liu H, Xia W, Zhu C. Effect of a novel copper-containing intrauterine device material on the endometrial environment in rabbits. Contraception 2018; 98:323-327. [PMID: 29935149 DOI: 10.1016/j.contraception.2018.06.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Revised: 06/05/2018] [Accepted: 06/11/2018] [Indexed: 12/24/2022]
Abstract
OBJECTIVE(S) This study aimed to determine whether intrauterine placement of a novel composite material [copper (Cu) microparticles, low-density polyethylene, and methyl vinyl silicone rubber (Cu/LDPE/MVQ)] could prevent pregnancy in rabbits, and to evaluate the effects of Cu/LDPE/MVQ on the endometrial environment. STUDY DESIGN Eighty sexually mature female rabbits were randomly divided into four groups (n=20 each group): control (sham-operated), LDPE/MVQ, Cu/LDPE/MVQ microcomposite, and bare Cu. Ten rabbits from each implant-bearing group were randomly selected for a mating experiment beginning 30 days after insertion. Pregnancy outcomes were observed 15 days after mating. Factors associated with endometrial bleeding and inflammation in the remaining rabbits in each group, and the surface conditions of the implants, were investigated 90 days post-insertion. RESULTS The Cu (0 embryo) and Cu/LDPE/MVQ (0 embryo) groups had significantly fewer embryos than the LDPE/MVQ (1.0±0.6 embryos, p<.05) and sham-operated groups (4.1±1.3 embryos, p<.05). Compared with bare Cu, the Cu/LDPE/MVQ composite material was associated with considerable reductions in injuries and factors associated with abnormal endometrial bleeding and inflammation, such as matrix metalloproteinase 9 (MMP9) and prostaglandin E2 (PGE2). Additionally, the surface of implanted Cu/LDPE/MVQ remained much smoother than that of implanted bare Cu. CONCLUSION(S) This novel Cu-containing intrauterine device material exhibits a similar effect in prevention of pregnancy with bare copper, and lower levels of inflammatory markers. IMPLICATIONS This study demonstrates the potential of the novel Cu/LDPE/MVQ microcomposite material as a future substitute for conventional intrauterine device materials.
Collapse
Affiliation(s)
- Shifu Hu
- Family Planning Research Institute, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China
| | - Yingying Wang
- Family Planning Research Institute, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China
| | - Dandan Ke
- Family Planning Research Institute, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China
| | - Fang Zhou
- Family Planning Research Institute, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China
| | - Guiping Cheng
- Family Planning Research Institute, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China
| | - Heyu Liu
- Family Planning Research Institute, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China
| | - Wei Xia
- Family Planning Research Institute, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China; Reproductive Medicine Center, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China
| | - Changhong Zhu
- Family Planning Research Institute, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China; Reproductive Medicine Center, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China.
| |
Collapse
|
20
|
Intrauterine Devices and Contraceptive Implants: Overview of Options and Updates on Method Use. CURRENT OBSTETRICS AND GYNECOLOGY REPORTS 2017. [DOI: 10.1007/s13669-017-0200-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
21
|
Black A, Guilbert E, Costescu D, Dunn S, Fisher W, Kives S, Mirosh M, Norman W, Pymar H, Reid R, Roy G, Varto H, Waddington A, Wagner MS, Whelan AM, Mansouri S. Canadian Contraception Consensus (Part 3 of 4): Chapter 7--Intrauterine Contraception. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2016; 38:182-222. [PMID: 27032746 DOI: 10.1016/j.jogc.2015.12.002] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVE To provide guidelines for health care providers on the use of contraceptive methods to prevent pregnancy and on the promotion of healthy sexuality. OUTCOMES Overall efficacy of cited contraceptive methods, assessing reduction in pregnancy rate, safety, ease of use, and side effects; the effect of cited contraceptive methods on sexual health and general well-being; and the relative cost and availability of cited contraceptive methods in Canada. EVIDENCE Published literature was retrieved through searches of Medline and The Cochrane Database from January 1994 to January 2015 using appropriate controlled vocabulary (e.g., contraception, sexuality, sexual health) and key words (e.g., contraception, family planning, hormonal contraception, emergency contraception). Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies published in English from January 1994 to January 2015. Searches were updated on a regular basis in incorporated in the guideline to June 2015. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. VALUES The quality of the evidence in this document was rated using the criteria described in the Report of the Canadian Task Force on Preventive Health Care (Table 1). CHAPTER 7: INTRAUTERINE CONTRACEPTION: SUMMARY STATEMENTS 1. Intrauterine contraceptives are as effective as permanent contraception methods. (II-2) 2. The use of levonorgestrel-releasing intrauterine system (LNG-IUS) 52 mg by patients taking tamoxifen is not associated with recurrence of breast cancer. (I) 3. Intrauterine contraceptives have a number of noncontraceptive benefits. The levonorgestrel-releasing intrauterine system (LNG-IUS) 52 mg significantly decreases menstrual blood loss (I) and dysmenorrhea. (II-2) Both the copper intrauterine device and the LNG-IUS significantly decrease the risk of endometrial cancer. (II-2) 4. The risk of uterine perforation decreases with inserter experience but is higher in postpartum and breastfeeding women. (II-2) 5. The risk of pelvic inflammatory disease (PID) is increased slightly in the first month after intrauterine contraceptive (IUC) insertion, but the absolute risk is low. Exposure to sexually transmitted infections and not the IUC itself is responsible for PID occurring after the first month of use. (II-2) 6. Nulliparity is not associated with an increased risk of intrauterine contraceptive expulsion. (II-2) 7. Ectopic pregnancy with an intrauterine contraceptive (IUC) is rare, but when a pregnancy occurs with an IUC in situ, it is an ectopic pregnancy in 15% to 50% of the cases. (II-2) 8. In women who conceive with an intrauterine contraceptive (IUC) in place, early IUC removal improves outcomes but does not entirely eliminate risks. (II-2) 9. Intrauterine contraceptives do not increase the risk of infertility. (II-2) 10. Immediate insertion of an intrauterine contraceptive (10 minutes postplacental to 48 hours) postpartum or post-Caesarean section is associated with a higher continuation rate compared with insertion at 6 weeks postpartum. (I) 11. Immediate insertion of an intrauterine contraceptive (IUC; 10 minutes postplacental to 48 hours) postpartum or post-Caesarean section is associated with a higher risk of expulsion. (I) The benefit of inserting an IUC immediately postpartum or post-Caesarean section outweighs the disadvantages of increased risk of perforation and expulsion. (II-C) 12. Insertion of an intrauterine contraceptive in breastfeeding women is associated with a higher risk of uterine perforation in the first postpartum year. (II-2) 13. Immediate insertion of an intrauterine contraceptive (IUC) post-abortion significantly reduces the risk of repeat abortion (II-2) and increases IUC continuation rates at 6 months. (I) 14. Antibiotic prophylaxis for intrauterine contraceptive insertion does not significantly reduce postinsertion pelvic infection. (I) RECOMMENDATIONS: 1. Health care professionals should be careful not to restrict access to intrauterine contraceptives (IUC) owing to theoretical or unproven risks. (III-A) Health care professionals should offer IUCs as a first-line method of contraception to both nulliparous and multiparous women. (II-2A) 2. In women seeking intrauterine contraception (IUC) and presenting with heavy menstrual bleeding and/or dysmenorrhea, health care professionals should consider the use of the levonorgestrel intrauterine system 52 mg over other IUCs. (I-A) 3. Patients with breast cancer taking tamoxifen may consider a levonorgestrel-releasing intrauterine system 52 mg after consultation with their oncologist. (I-A) 4. Women requesting a levonorgestrel-releasing intrauterine system or a copper-intrauterine device should be counseled regarding changes in bleeding patterns, sexually transmitted infection risk, and duration of use. (III-A) 5. A health care professional should be reasonably certain that the woman is not pregnant prior to inserting an intrauterine contraceptive at any time during the menstrual cycle. (III-A) 6. Health care providers should consider inserting an intrauterine contraceptive immediately after an induced abortion rather than waiting for an interval insertion. (I-B) 7. In women who conceive with an intrauterine contraceptive (IUC) in place, the diagnosis of ectopic pregnancy should be excluded as arly as possible. (II-2A) Once an ectopic pregnancy has been excluded, the IUC should be removed without an invasive procedure. The IUC may be removed at the time of a surgical termination. (II-2B) 8. In the case of pelvic inflammatory disease, it is not necessary to remove the intrauterine contraceptive unless there is no clinical improvement after 48 to 72 hours of appropriate antibiotic treatment. (II-2B) 9. Routine antibiotic prophylaxis for intrauterine contraceptive (IUC) insertion is not indicated. (I-B) Health care providers should perform sexually transmitted infection (STI) testing in women at high risk of STI at the time of IUC insertion. If the test is positive for chlamydia and/or gonorrhea, the woman should be appropriately treated postinsertion and the IUC can remain in situ. (II-2B) 10. Unscheduled bleeding in intrauterine contraception users, when persistent or associated with pelvic pain, should be investigated to rule out infection, pregnancy, gynecological pathology, expulsion or malposition. (III-A)
Collapse
|
22
|
Bahamondes L, Makuch MY, Monteiro I, Marin V, Lynen R. Knowledge and attitudes of Latin American obstetricians and gynecologists regarding intrauterine contraceptives. Int J Womens Health 2015; 7:717-22. [PMID: 26213479 PMCID: PMC4509537 DOI: 10.2147/ijwh.s84173] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND Intrauterine contraceptives (IUCs), including the copper intrauterine device and the levonorgestrel-releasing intrauterine system (LNG-IUS), are among the reversible contraceptive methods with high effectiveness. However, use is low in many settings, including some Latin American countries, mainly due to the influences of myths, fears, and negative attitudes, not only of users and potential users, but also of different cadres of health care professionals. The purpose of this study was to assess the knowledge and attitudes of a group of Latin American obstetricians and gynecologists regarding IUCs. METHODS A survey was conducted during a scientific meeting organized in Chile in 2014 to present and discuss updated information about contraception. Obstetricians and gynecologists from 12 Latin American countries, who reported that they provide daily contraception services in both the public and private sectors, participated in the meeting. Participants who agreed to take part in the survey responded to a multiple-choice questionnaire on issues regarding knowledge, use, and attitudes about IUCs. RESULTS Of the 210 obstetricians and gynecologists participating in the meeting, the respondents to each question varied from 168 (80.0%) to 205 (97.6%). Almost 50% recognized that the failure rate of combined oral contraceptives, patches, and vaginal rings is 8%-10%. Furthermore, 10% of the participants did not recognize the high contraceptive effectiveness of long-acting reversible contraceptive methods. Additionally, almost 80% of the respondents answered that they did not offer IUCs to nulligravidas and almost 10% did not offer IUCs to adolescents, albeit almost 90% of the respondents reported that nulligravidas are candidates for an LNG-IUS. CONCLUSION Some deficiencies and contradictions in terms of knowledge and attitudes were identified from the answers of the Latin American obstetricians and gynecologists who participated in the survey. The knowledge and attitudes of health care professionals about IUCs are important in order to provide adequate counseling and to expand the use of IUCs.
Collapse
Affiliation(s)
- Luis Bahamondes
- Department of Obstetrics and Gynecology, School of Medical Sciences, University of Campinas, Campinas, Brazil
| | - Maria Y Makuch
- Department of Obstetrics and Gynecology, School of Medical Sciences, University of Campinas, Campinas, Brazil
| | - Ilza Monteiro
- Department of Obstetrics and Gynecology, School of Medical Sciences, University of Campinas, Campinas, Brazil
| | - Victor Marin
- Department of Obstetrics and Gynecology, Hospital Central, Petróleos Mexicanos, México City, Mexico
| | | |
Collapse
|
23
|
Bahamondes L, Bottura BF, Bahamondes MV, Gonçalves MP, Correia VM, Espejo-Arce X, Sousa MH, Monteiro I, Fernandes A. Estimated disability-adjusted life years averted by long-term provision of long acting contraceptive methods in a Brazilian clinic. Hum Reprod 2014; 29:2163-70. [PMID: 25085802 DOI: 10.1093/humrep/deu191] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
STUDY QUESTION What is the contribution of the provision, at no cost for users, of long acting reversible contraceptive methods (LARC; copper intrauterine device [IUD], the levonorgestrel-releasing intrauterine system [LNG-IUS], contraceptive implants and depot-medroxyprogesterone [DMPA] injection) towards the disability-adjusted life years (DALY) averted through a Brazilian university-based clinic established over 30 years ago. SUMMARY ANSWER Over the last 10 years of evaluation, provision of LARC methods and DMPA by the clinic are estimated to have contributed to DALY averted by between 37 and 60 maternal deaths, 315-424 child mortalities, 634-853 combined maternal morbidity and mortality and child mortality, and 1056-1412 unsafe abortions averted. WHAT IS KNOWN ALREADY LARC methods are associated with a high contraceptive effectiveness when compared with contraceptive methods which need frequent attention; perhaps because LARC methods are independent of individual or couple compliance. However, in general previous studies have evaluated contraceptive methods during clinical studies over a short period of time, or not more than 10 years. Furthermore, information regarding the estimation of the DALY averted is scarce. STUDY DESIGN, SIZE AND DURATION We reviewed 50 004 medical charts from women who consulted for the first time looking for a contraceptive method over the period from 2 January 1980 through 31 December 2012. PARTICIPANTS/MATERIALS, SETTING, METHODS Women who consulted at the Department of Obstetrics and Gynaecology, University of Campinas, Brazil were new users and users switching contraceptive, including the copper IUD (n = 13 826), the LNG-IUS (n = 1525), implants (n = 277) and DMPA (n = 9387). Estimation of the DALY averted included maternal morbidity and mortality, child mortality and unsafe abortions averted. MAIN RESULTS AND THE ROLE OF CHANCE We obtained 29 416 contraceptive segments of use including 25 009 contraceptive segments of use from 20 821 new users or switchers to any LARC method or DMPA with at least 1 year of follow-up. The mean (± SD) age of the women at first consultation ranged from 25.3 ± 5.7 (range 12-47) years in the 1980s, to 31.9 ± 7.4 (range 16-50) years in 2010-2011. The most common contraceptive chosen at the first consultation was copper IUD (48.3, 74.5 and 64.7% in the 1980s, 1990s and 2000s, respectively). For an evaluation over 20 years, the cumulative pregnancy rates (SEM) were 0.4 (0.2), 2.8 (2.1), 4.0 (0.4) and 1.3 (0.4) for the LNG-IUS, the implants, copper IUD and DMPA, respectively and cumulative continuation rates (SEM) were 15.1 (3.7), 3.9 (1.4), 14.1 (0.6) and 7.3 (1.7) for the LNG-IUS, implants, copper IUD and DMPA, respectively (P < 0.001). Over the last 10 years of evaluation, the estimation of the contribution of the clinic through the provision of LARC methods and DMPA to DALY averted was 37-60 maternal deaths; between 315 and 424 child mortalities; combined maternal morbidity and mortality and child mortality of between 634 and 853, and 1056-1412 unsafe abortions averted. LIMITATIONS, REASONS FOR CAUTION The main limitations are the number of women who never returned to the clinic (overall 14% among the four methods under evaluation); consequently the pregnancy rate could be different. Other limitations include the analysis of two kinds of copper IUD and two kinds of contraceptive implants as the same IUD or implant, and the low number of users of implants. In addition, the DALY calculation relies on a number of estimates, which may vary in different parts of the world. WIDER IMPLICATIONS OF THE FINDINGS LARC methods and DMPA are highly effective and women who were well-counselled used these methods for a long time. The benefit of averting maternal morbidity and mortality, child mortality, and unsafe abortions is an example to health policy makers to implement more family planning programmes and to offer contraceptive methods, mainly LARC and DMPA, at no cost or at affordable cost for the underprivileged population. STUDY FUNDING/COMPETING INTERESTS This study received partial financial support from the Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP), grant # 2012/12810-4 and from the National Research Council (CNPq), grant #573747/2008-3. B.F.B., M.P.G., and V.M.C. were fellows from the scientific initiation programme from FAPESP. Since the year 2001, all the TCu380A IUD were donated by Injeflex, São Paulo, Brazil, and from the year 2006 all the LNG-IUS were donated by the International Contraceptive Access Foundation (ICA), Turku, Finland. Both donations are as unrestricted grants. The authors declare that there are no conflicts of interest associated with this study.
Collapse
Affiliation(s)
- Luis Bahamondes
- Human Reproduction Unit, Department of Obstetrics and Gynaecology, School of Medical Sciences and the National Institute of Hormones and Women's Health, University of Campinas (UNICAMP), Campinas, SP, Brazil
| | - Bruna F Bottura
- Human Reproduction Unit, Department of Obstetrics and Gynaecology, School of Medical Sciences and the National Institute of Hormones and Women's Health, University of Campinas (UNICAMP), Campinas, SP, Brazil
| | - M Valeria Bahamondes
- Human Reproduction Unit, Department of Obstetrics and Gynaecology, School of Medical Sciences and the National Institute of Hormones and Women's Health, University of Campinas (UNICAMP), Campinas, SP, Brazil
| | - Mayara P Gonçalves
- Human Reproduction Unit, Department of Obstetrics and Gynaecology, School of Medical Sciences and the National Institute of Hormones and Women's Health, University of Campinas (UNICAMP), Campinas, SP, Brazil
| | - Vinicius M Correia
- Human Reproduction Unit, Department of Obstetrics and Gynaecology, School of Medical Sciences and the National Institute of Hormones and Women's Health, University of Campinas (UNICAMP), Campinas, SP, Brazil
| | - Ximena Espejo-Arce
- Human Reproduction Unit, Department of Obstetrics and Gynaecology, School of Medical Sciences and the National Institute of Hormones and Women's Health, University of Campinas (UNICAMP), Campinas, SP, Brazil
| | - Maria H Sousa
- Human Reproduction Unit, Department of Obstetrics and Gynaecology, School of Medical Sciences and the National Institute of Hormones and Women's Health, University of Campinas (UNICAMP), Campinas, SP, Brazil
| | - Ilza Monteiro
- Human Reproduction Unit, Department of Obstetrics and Gynaecology, School of Medical Sciences and the National Institute of Hormones and Women's Health, University of Campinas (UNICAMP), Campinas, SP, Brazil
| | - Arlete Fernandes
- Human Reproduction Unit, Department of Obstetrics and Gynaecology, School of Medical Sciences and the National Institute of Hormones and Women's Health, University of Campinas (UNICAMP), Campinas, SP, Brazil
| |
Collapse
|
24
|
Extended use of the intrauterine device: a literature review and recommendations for clinical practice. Contraception 2014; 89:495-503. [DOI: 10.1016/j.contraception.2014.02.011] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2013] [Revised: 02/15/2014] [Accepted: 02/17/2014] [Indexed: 11/17/2022]
|
25
|
Abstract
This article summarizes the literature regarding the epidemiology and prevention of unintended pregnancy in the United States. Because of the Affordable Care Act and its accompanying contraceptive provision, there is a need for more primary care clinicians to provide family planning services. Office-based interventions to incorporate family planning services in primary care are presented, including clinical tools and electronic health record use. Special attention is paid to long-acting reversible contraceptive methods (the subdermal implant and intrauterine devices); these highly effective and safe methods have the greatest potential to decrease the rate of unintended pregnancy, but have been underused.
Collapse
|
26
|
Ferreira JM, Nunes FR, Modesto W, Gonçalves MP, Bahamondes L. Reasons for Brazilian women to switch from different contraceptives to long-acting reversible contraceptives. Contraception 2014; 89:17-21. [DOI: 10.1016/j.contraception.2013.09.012] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2013] [Revised: 09/14/2013] [Accepted: 09/19/2013] [Indexed: 12/27/2022]
|
27
|
Cappiello J, Bosak J. IUDs: beyond the basics. Nurse Pract 2013; 38:40-46. [PMID: 23958671 DOI: 10.1097/01.npr.0000433075.30022.81] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This article reviews the changes in patient selection for intrauterine devices (IUDs) and evidence-based practices regarding counseling and management of common IUD issues. Where evidence-based research is lacking, expert opinion and common standards of practice are reviewed, and current clinical resources are identified.
Collapse
|
28
|
Management of missing strings in users of intrauterine contraceptives. Contraception 2012; 86:354-8. [DOI: 10.1016/j.contraception.2012.01.018] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2012] [Revised: 01/30/2012] [Accepted: 01/31/2012] [Indexed: 11/22/2022]
|
29
|
Bahamondes L, Bahamondes MV. Assessment of the use of two new low-dose levonorgestrel-releasing intrauterine systems as contraceptives. WOMENS HEALTH 2012; 8:235-8. [PMID: 22554171 DOI: 10.2217/whe.12.12] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Evaluation of: Gemzell-Danielsson K, Schellschmidt I, Apter D. A randomized, Phase II study describing the efficacy, bleeding profile, and safety of two low-dose levonorgestrel-releasing intrauterine contraceptive systems and Mirena. Fertil. Steril. 97(3), 616-622.e3 (2012). A randomized, open-label, Phase II study was conducted in 37 centers in five European countries to assess the optimal dose for a new contraceptive levonorgestrel intrauterine system (LNG-IUS). Overall, 742 parous or nulliparous women aged 21-40 years were allocated to receive a LNG-IUS that initially releases 12 µg/day (LNG-IUS(12)) or 16 µg/day (LNG-IUS(16)) in vitro or the currently available device that releases 20 µg/day (LNG-IUS(20)). The two new devices are shorter than the current one. Pearl Indices of 0.17, 0.82 and 0.00 for the LNG-IUS(12), LNG-IUS(16) and LNG-IUS(20), respectively, reflect the contraceptive efficacy of these devices. The mean number of bleeding and spotting days decreased in all three groups; however, this decrease was more significant in LNG-IUS(20) users. Placement of the new shorter devices was considered simple by providers, while patients reported significantly less pain with the two new devices compared with the current one. This study provided further insight into the development of two new LNG-IUS devices as contraceptives, with the additional possibility of using them to treat heavy menstrual bleeding or as endometrial protection during estrogen therapy.
Collapse
Affiliation(s)
- Luis Bahamondes
- Human Reproduction Unit, Department of Obstetrics & Gynecology, School of Medical Sciences, University of Campinas (UNICAMP), Caixa Postal 6181, 13084-971 Campinas, SP, Brazil.
| | | |
Collapse
|
30
|
Sivin I, Batár I. State-of-the-art of non-hormonal methods of contraception: III. Intrauterine devices. EUR J CONTRACEP REPR 2012; 15:96-112. [PMID: 20230337 DOI: 10.3109/13625180903519885] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Since the 1959 revival of the IUD, non-hormonal devices have become the most widely used of all reversible contraceptives. Pregnancy rates of copper-releasing IUDs in current use range from approximately 0.5 to 1.5 per hundred continuing users in the first year, with somewhat lower annual pregnancy rates thereafter. Evidence-based research has been systematically conducted and translated into guidelines for eligibility criteria and problem management. Recent device research, beyond the T, Multiload and frameless devices has centred on improved designs such as U ,Y and Slimline shapes, or enhanced copper release, the latter through electrochemical effects or nanotechnology applications. Other IUD research foci concern devices that decrease bleeding and pain by releasing non-steroidal anti-inflammatory drugs. Yet other research lines indicate noncontraceptive benefits of copper intrauterine devices in protecting against endometrial cancer, and favourable risk-benefit analyses of IUD use by women at risk of or post HIV infection. IUD mechanisms of action and the relation of IUDs to pelvic infection and ectopic pregnancy are briefly reviewed. For our literature search we used Medline, Popline and Cochrane Library data bases, Google search, our personal files, and the references contained in articles in our files.
Collapse
|
31
|
Bahamondes MV, Hidalgo MM, Bahamondes L, Monteiro I. Ease of insertion and clinical performance of the levonorgestrel-releasing intrauterine system in nulligravidas. Contraception 2011; 84:e11-6. [DOI: 10.1016/j.contraception.2011.05.012] [Citation(s) in RCA: 65] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2011] [Revised: 04/08/2011] [Accepted: 05/19/2011] [Indexed: 11/27/2022]
|
32
|
Nelson AL. Safety, Efficacy, and Patient Acceptability of the Copper T-380A Intrauterine Contraceptive Device. CLINICAL MEDICINE INSIGHTS. WOMEN'S HEALTH 2011. [DOI: 10.4137/cmwh.s5332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The ParaGard Copper T 380A intrauterine device (CuT380A) provides reversible contraception that is as effective as sterilization for up to 20 years. The CuT380A is a mainstream, first-line contraceptive option for most healthy women, including nulligravid women, as well as many women who have serious medical problems. Because it is the most cost-effective method of birth control, the CuT380A is the preferred IUD, except for women who desire lighter or no menstrual blood loss. Surveys reveal that 95% of US CuT380A users are “very” or “somewhat” satisfied with their method. This article describes current candidates for IUD use, discusses the mechanisms of action of the CuT380A, provides guidance to reduce barriers to IUD access, suggests counseling points for patients, and outlines techniques to reduce the risks and side effects that can be associated with use of the CuT380A.
Collapse
Affiliation(s)
- Anita L. Nelson
- Department of Obstetrics and Gynecology, Harbor-UCLA Medical Center, Torrance, CA, USA
| |
Collapse
|
33
|
Length of the endometrial cavity and intrauterine contraceptive device expulsion. Int J Gynaecol Obstet 2011; 113:50-3. [DOI: 10.1016/j.ijgo.2010.10.013] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2010] [Revised: 10/22/2010] [Accepted: 12/14/2010] [Indexed: 11/21/2022]
|
34
|
Kaneshiro B, Aeby T. Long-term safety, efficacy, and patient acceptability of the intrauterine Copper T-380A contraceptive device. Int J Womens Health 2010; 2:211-20. [PMID: 21072313 PMCID: PMC2971735 DOI: 10.2147/ijwh.s6914] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2010] [Indexed: 11/23/2022] Open
Abstract
The intrauterine device (IUD), primarily in the form of the copper IUD, is used by more than 150 million women around the world, making it the most widely used reversible method of contraception. With a remarkably low failure rate of less than 1 per 100 women in the first year of use, the Copper T-380A is in the top tier of contraceptives in terms of efficacy. Risks of utilization include perforation and an increased risk of infection in the first 20 days following insertion. Overall, the number of adverse events is low, making the Copper T-380A a very safe contraceptive method. The most common reasons for the discontinuation of this method are menstrual bleeding and dysmenorrhea. However, cumulative discontinuation rates of Copper T-380A are lower than that have been reported for other methods, indicating that the Copper T-380A is highly acceptable to women. After 5 years, approximately 50% of all women, who have a Copper T-380A inserted, will continue to use this highly effective contraceptive method.
Collapse
Affiliation(s)
- Bliss Kaneshiro
- Department of Obstetrics and Gynecology, John A Burns School of Medicine, University of Hawaii, Honolulu, Hawaii, USA
| | - Tod Aeby
- Department of Obstetrics and Gynecology, John A Burns School of Medicine, University of Hawaii, Honolulu, Hawaii, USA
| |
Collapse
|
35
|
de Araujo FF, Barbieri M, Guazzelli CAF, Lindsey PC. The T 380A intrauterine device: a retrospective 5-year evaluation. Contraception 2008; 78:474-8. [DOI: 10.1016/j.contraception.2008.07.006] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2007] [Revised: 07/03/2008] [Accepted: 07/05/2008] [Indexed: 11/26/2022]
|
36
|
Tetrault AM, Richman SM, Fei X, Taylor HS. Decreased endometrial HOXA10 expression associated with use of the copper intrauterine device. Fertil Steril 2008; 92:1820-4. [PMID: 18930214 DOI: 10.1016/j.fertnstert.2008.08.134] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2008] [Revised: 08/26/2008] [Accepted: 08/29/2008] [Indexed: 10/21/2022]
Abstract
OBJECTIVE To characterize human endometrial HOXA10 expression in patients using a copper intrauterine device (IUD). DESIGN Case-control study. SETTING Academic medical center. PATIENT(S) Women using copper IUDs. INTERVENTION(S) Immunohistochemical analysis of endometrial HOXA10 expression in biopsy samples obtained from 24 women using a copper Paraguard T380A as well as in samples obtained from 10 normal cycling women who were not using an IUD or hormonal contraceptives. MAIN OUTCOME MEASURE(S) Endometrial HOXA10 expression. RESULT(S) Endometrial HOXA10 expression was markedly decreased in the biopsy samples obtained from women using the IUD contraceptive when compared with controls. The mean H score for endometrial stromal cell HOXA10 expression in samples obtained from women using the Paraguard IUD was 0.21 compared with 2.2 in the control endometrial biopsy samples. Endometrial glandular expression of HOXA10 was absent in all IUD users. CONCLUSION(S) Decreased endometrial HOXA10 expression was apparent in women who use a copper IUD. Expression of HOXA10 is essential for endometrial receptivity. A novel mechanism of copper IUD action involves suppression of genes required for endometrial receptivity. The dramatic decrease of endometrial HOXA10 in response to IUD use may contribute to contraceptive efficacy.
Collapse
Affiliation(s)
- Amy M Tetrault
- Division of Reproductive Endocrinology and Infertility, Department of Obstetrics, Gynecology and Reproductive Sciences, Yale University School of Medicine, New Haven, Connecticut 06510, USA
| | | | | | | |
Collapse
|
37
|
Thonneau PF, Almont T. Contraceptive efficacy of intrauterine devices. Am J Obstet Gynecol 2008; 198:248-53. [PMID: 18221924 DOI: 10.1016/j.ajog.2007.10.787] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2007] [Revised: 10/01/2007] [Accepted: 10/01/2007] [Indexed: 11/17/2022]
Abstract
To compare the contraceptive efficacy of various types of intrauterine devices (IUD; copper devices, Nova-T, intrauterine contraceptive systems, levonorgestrel-releasing devices), we reviewed all relevant publications on this subject that have been published over the last 2 decades. The first point to be highlighted by this review is the excellent effectiveness of IUDs, with a global cumulative pregnancy rate <2% at 5 years, whatever the type of device used. We observed a large variation in efficacy rate according to the type of IUD and also according to study design. Nevertheless, of all the types of IUDs, the levonorgestrel-releasing IUD and to a lesser extent the TCu380A IUD seem to be the most effective, with a cumulative pregnancy rate at 5 years of <0.5% for the levonorgestrel-releasing IUD and between 0.3% and 0.6% for the TCu380A IUD.
Collapse
|
38
|
Xia X, Xie C, Zhu C, Cai S, Yang X. Effect of implanted Cu/low-density polyethylene nanocomposite on the morphology of endometrium in the mouse. Fertil Steril 2007; 88:472-8. [PMID: 17335821 DOI: 10.1016/j.fertnstert.2006.11.122] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2006] [Revised: 11/27/2006] [Accepted: 11/27/2006] [Indexed: 10/23/2022]
Abstract
OBJECTIVE To investigate the damage of endometrium caused by the implanted Cu/low-density polyethylene (LDPE) nanocomposite and the contraceptive effect of this novel copper-containing intrauterine device material. DESIGN Experimental animal study. SETTING TongJi Medical College of Huazhong University of Science and Technology. PATIENT(S) Sixty healthy female mice. INTERVENTION(S) Twenty mice received no implants, 20 mice received the Cu/LDPE nanocomposite, and 20 mice received bulk copper. MAIN OUTCOME MEASURE(S) Morphologic features of the endometrium, contraceptive effect, and surface condition of the implanted implants. RESULT(S) The contraceptive effect of both the Cu/LDPE nanocomposite and bulk copper is 100%, the damage of the endometrium caused by the Cu/LDPE nanocomposite is much less than that caused by bulk copper, and the surface of the implanted Cu/LDPE nanocomposite is much smoother and much softer than that of the implanted bulk copper. CONCLUSION(S) The contraceptive effect of the Cu/LDPE nanocomposite is comparable with that of bulk copper, and the damage of the endometrium caused by the Cu/LDPE nanocomposite is much less than that caused by bulk copper. The endometrium injury is related to the surface condition of the implanted intrauterine device material.
Collapse
Affiliation(s)
- Xianping Xia
- Department of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan, China
| | | | | | | | | |
Collapse
|
39
|
Sivin I. Utility and drawbacks of continuous use of a copper T IUD for 20 years. Contraception 2007; 75:S70-5. [PMID: 17531620 DOI: 10.1016/j.contraception.2007.01.016] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2007] [Accepted: 01/12/2007] [Indexed: 11/26/2022]
Abstract
This article examines interrelated questions concerning the extent of need for contraception in women 40 years and older and the degree to which that need can be served when use of collared T IUDs is initiated in women aged 25-35 years. Differentials in the impacts of intrauterine device (IUD) use on health issues in the second decade of contraception are also addressed. Although fertility of all women aged 40-44 years is below 100 per 1000 in all regions of the world today, the risk of pregnancy among married or cohabiting women who do not use contraception is estimated at 270-300 per 1000 or 27-30% per year. At ages 45-49 years, the annual risk of pregnancy to women in union who do not use contraception lies at or above 10% per year. Data from three studies show that users of collared copper IUDs who continued using the same device beyond the completion of 10 years experienced no pregnancies through the end of 15 years. A small number of women continued with the same IUD through 20 years and still experienced no pregnancies. Use of collared copper T IUDs beyond 10 years was not associated with intensification of side effects nor with an increase in the relative frequency of those effects, with the exception of the experience of perimenopausal symptoms and problems. Neither increased bleeding nor increased severity of pelvic disease was manifest in the second decade of continuous use of the same IUD, as compared with the first decade of such use. Under our current understanding of the duration of IUD effectiveness, only a small percentage of women complete 10 years of use. Even with revised understanding of the duration of effectiveness of long-acting copper devices, average annual continuation rates must be quite high in order that 20% of women aged 25-35 years initiate a second decade of continuous IUD use. Those who do so would find considerable protection against pregnancy and reasonable economic benefits in continuing to use the same device.
Collapse
Affiliation(s)
- Irving Sivin
- Center for Biomedical Research, Population Council, New York, NY 10021, USA.
| |
Collapse
|