1
|
Sawada T, Okawara H, Nakashima D, Aoki K, Namba M, Iwabuchi S, Katsumata Y, Nakamura M, Nagura T. Local alternating heat and cold stimulation affects hemodynamics and oxygenation in fatigued muscle tissue and autonomic nervous activity: a single-arm interventional study. J Physiol Anthropol 2024; 43:11. [PMID: 38528599 DOI: 10.1186/s40101-024-00358-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 03/20/2024] [Indexed: 03/27/2024] Open
Abstract
BACKGROUND Local alternating heat and cold stimulation as an alternative to contrast bath may cause intermittent vasoconstriction and vasodilation, inducing a vascular pumping effect and consequently promoting increased tissue blood flow and oxygenation. This study aimed to examine the effects of local alternating heat and cold stimulation, using a wearable thermal device, on the hemodynamics of fatigued muscle tissue and autonomic nervous activity. METHODS Twenty healthy individuals experienced fatigue in the periarticular muscles of the shoulder joint due to a typing task. Local alternating heat and cold stimulations were then applied to the upper trapezius muscle. Muscle hardness was measured using a muscle hardness meter, and muscle tissue hemodynamics and oxygenation were evaluated using near-infrared spectroscopy before and after the stimulation. Autonomic nervous activity was also evaluated using heart rate variability. RESULTS Alternating heat and cold stimulation decreased muscle hardness of the fatigued trapezius muscle from 1.38 ± 0.15 to 1.31 ± 0.14 N (P < 0.01). The concentration of total hemoglobin in the trapezius muscle tissue increased from - 0.21 ± 1.36 to 2.29 ± 3.42 µmol/l (P < 0.01), and the tissue hemoglobin oxygen saturation also increased from 70.1 ± 5.4 to 71.1 ± 6.0% (P < 0.05). Additionally, the heart rate variability parameter, which is an index of sympathetic nervous activity, increased from 3.82 ± 2.96 to 6.86 ± 3.49 (P < 0.01). A correlation was found between increased tissue hemoglobin oxygen saturation and increased parameters of sympathetic nervous activity (r = 0.50, P < 0.05). CONCLUSIONS Local alternating heat and cold stimulation affected the hemodynamic response in fatigued muscle tissue and autonomic nervous activity. This stimulation is more efficient than conventional contrast baths in terms of mobility and temperature control and has potential as a new versatile therapeutic intervention for muscle fatigue. TRIAL REGISTRATION UMIN-CTR (UMIN000040087: registered on April 7, 2020, https://upload.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000045710 . UMIN000040620: registered on June 1, 2020, https://upload.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000046359 ).
Collapse
Affiliation(s)
- Tomonori Sawada
- Diagnosis and Treatment Division, Nagura Orthopedic Clinic, Chuo, Tokyo, Japan
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Hiroki Okawara
- Diagnosis and Treatment Division, Nagura Orthopedic Clinic, Chuo, Tokyo, Japan
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Daisuke Nakashima
- Diagnosis and Treatment Division, Nagura Orthopedic Clinic, Chuo, Tokyo, Japan.
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan.
- Department of Clinical Biomechanics, Keio University School of Medicine, Shinjuku, Tokyo, Japan.
| | - Kentaro Aoki
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Mira Namba
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Shuhei Iwabuchi
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Yoshinori Katsumata
- Institute for Integrated Sports Medicine, Keio University School of Medicine, Shinjuku, Tokyo, Japan
- Department of Cardiology, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Masaya Nakamura
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Takeo Nagura
- Diagnosis and Treatment Division, Nagura Orthopedic Clinic, Chuo, Tokyo, Japan
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
- Department of Clinical Biomechanics, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| |
Collapse
|
2
|
Koruyucu AN, Aşantoğrol F. Determination of masseter and temporal muscle thickness by ultrasound and muscle hardness by shear wave elastography in healthy adults as reference values. Dentomaxillofac Radiol 2024; 53:137-152. [PMID: 38211311 DOI: 10.1093/dmfr/twad013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 10/16/2023] [Accepted: 12/17/2023] [Indexed: 01/13/2024] Open
Abstract
OBJECTIVES The purpose of this study is to prospectively investigate the reference values of masseter and temporal muscle thicknesses by ultrasonography and muscle hardness values by shear wave elastography in healthy adults. METHODS The sample of the study consisted of a total of 160 healthy individuals aged between 18 and 59, including 80 women and 80 men. By examining the right and left sides of each participant, thickness and hardness values were obtained for 320 masseter muscles and 320 temporal muscles in total. RESULTS The mean masseter muscle thickness was found to be 1.09 cm at rest and 1.40 cm in contraction. The mean temporal muscle thickness was found to be 0.88 cm at rest and 0.98 cm in contraction. The thickness values of the masseter and temporal muscles were significantly greater in the male participants than in the female participants (P < .001). While there were significant differences between the right and left masseter muscle thickness values at rest and in contraction, the values of the temporal muscles did not show a significant difference between the sides. While the resting hardness (rSWE) of the masseter muscle was transversally 6.91 kPa and longitudinally 8.49 kPa, these values in contraction (cSWE) were found, respectively, 31.40 and 35.65 kPa. The median temporal muscle hardness values were 8.84 kPa at rest and 20.43 kPa in contraction. Masseter and temporal muscle hardness values at rest and in contraction were significantly higher among the male participants compared to the female participants (P < .001). CONCLUSION In this study, reference values for the thickness and hardness of the masseter and temporal muscles are reported. Knowing these values will make it easier to assess pain in the masseter and temporal muscles and determine the diagnosis and prognosis of masticatory muscle pathologies by allowing the morphological and functional assessments of these muscles, and it will identify ranges for reference parameters.
Collapse
Affiliation(s)
- Ayşe Nur Koruyucu
- Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Gaziantep University, 27310 Gaziantep, Turkey
| | - Firdevs Aşantoğrol
- Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Gaziantep University, 27310 Gaziantep, Turkey
| |
Collapse
|
3
|
Takeuchi K, Nakamura M, Konrad A, Mizuno T. Long-term static stretching can decrease muscle stiffness: A systematic review and meta-analysis. Scand J Med Sci Sports 2023; 33:1294-1306. [PMID: 37231582 DOI: 10.1111/sms.14402] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 04/28/2023] [Accepted: 05/08/2023] [Indexed: 05/27/2023]
Abstract
Stretch training increases the range of motion of a joint. However, to date, the mechanisms behind such a stretching effect are not well understood. An earlier meta-analysis on several studies reported no changes in the passive properties of a muscle (i.e., muscle stiffness) following long-term stretch training with various types of stretching (static, dynamic, and proprioceptive neuromuscular stretching). However, in recent years, an increasing number of papers have reported the effects of long-term static stretching on muscle stiffness. The purpose of the present study was to examine the long-term (≥2 weeks) effect of static stretching training on muscle stiffness. PubMed, Web of Science, and EBSCO published before December 28, 2022, were searched and 10 papers met the inclusion criteria for meta-analysis. By applying a mixed-effect model, subgroup analyses, which included comparisons of sex (male vs. mixed sex) and type of muscle stiffness assessment (calculated from the muscle-tendon junction vs. shear modulus), were performed. Furthermore, a meta-regression was conducted to examine the effect of total stretching duration on muscle stiffness. The result of the meta-analysis showed a moderate decrease in muscle stiffness after 3-12 weeks of static stretch training compared to a control condition (effect size = -0.749, p < 0.001, I2 = 56.245). Subgroup analyses revealed no significant differences between sex (p = 0.131) and type of muscle stiffness assessment (p = 0.813). Moreover, there was no significant relationship between total stretching duration and muscle stiffness (p = 0.881).
Collapse
Affiliation(s)
- Kosuke Takeuchi
- Department of Physical Therapy, Faculty of Rehabilitation, Kobe International University, Kobe-shi, Japan
| | - Masatoshi Nakamura
- Faculty of Rehabilitation Sciences, Department of Physical Therapy, Nishi Kyushu University, Kanzaki-cho, Japan
| | - Andreas Konrad
- Institute of Human Movement Science, Sport and Health, Graz University, Graz, Austria
| | - Takamasa Mizuno
- Research Center of Health, Physical Fitness and Sports, Nagoya University, Nagoya-shi, Japan
| |
Collapse
|
4
|
Shimizu K, Watanabe N, Yoneda M, Nishimura S, Kobayashi T. Determination of the reference range for semi-quantified elasticity of healthy supraspinatus muscles using real-time tissue elastography and its clinical use in patients after rotator cuff repair. Clin Biomech (Bristol, Avon) 2023; 104:105945. [PMID: 36963202 DOI: 10.1016/j.clinbiomech.2023.105945] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 01/20/2023] [Accepted: 03/15/2023] [Indexed: 03/26/2023]
Abstract
BACKGROUND The quantitative assessment of healthy supraspinatus muscle elasticity may provide clinically useful preliminary information after rotator cuff repairs. We aimed to determine the reference range for supraspinatus muscle semi-quantified elasticity and describe how it can be used clinically after rotator cuff repair. METHODS The elasticity of healthy bilateral supraspinatus muscles in 43 participants aged between 24 and 75 years (categorized into two subgroups: <50 and ≥ 50 years) was measured as a strain ratio at 0° and 60° of shoulder abduction using real-time tissue elastography. The reference and modified reference ranges calculated by excluding outliers for elasticity were determined using normal distribution methods for logarithmically transformed data. The modified reference range was applied to eight cases of rotator cuff repair. FINDINGS Strain ratios under and over 50 years of age were 1.63 vs. 2.21 at 0° of shoulder abduction (P = 0.028) and 0.92 vs. 1.29 at 60° of shoulder abduction (P = 0.002), respectively. Modified reference ranges for under and over 50 years of age were 0.72-4.17 and 0.98-4.50 at 0° of shoulder abduction and 0.38-1.95 and 0.56-2.76 at 60° of shoulder abduction, respectively. Among eight cases, two showed strain ratios above the reference range at 1 month postoperatively, and rehabilitation protocols were adjusted. INTERPRETATION A strain ratio above the reference range, especially above the upper limit at 0° of shoulder abduction, may indicate increased passive stiffness of the musculotendinous unit. Clinically, the reference range has the potential to be used as a baseline after rotator cuff repairs.
Collapse
Affiliation(s)
- Koshi Shimizu
- Department of Rehabilitation, Keyaki Clinic, Ishikawa, Japan; Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Ishikawa, Japan.
| | - Natsuki Watanabe
- Department of Rehabilitation, KKR Hokuriku Hospital, Ishikawa, Japan
| | - Mitsugu Yoneda
- Institute of Medical, Pharmaceutical, and Health Science, Kanazawa University, Ishikawa, Japan
| | - Seiji Nishimura
- Institute of Medical, Pharmaceutical, and Health Science, Kanazawa University, Ishikawa, Japan
| | - Takashi Kobayashi
- Department of Orthopedic Surgery, Hachioji Sports Clinic, Tokyo, Japan
| |
Collapse
|
5
|
Comparative Study of Muscle Hardness during Water-Walking and Land-Walking Using Ultrasound Real-Time Tissue Elastography in Healthy Young People. J Clin Med 2023; 12:jcm12041660. [PMID: 36836194 PMCID: PMC9959738 DOI: 10.3390/jcm12041660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 02/16/2023] [Accepted: 02/17/2023] [Indexed: 02/22/2023] Open
Abstract
Compared with land-walking, water-walking is considered to be beneficial as a whole-body exercise because of the characteristics of water (buoyancy, viscosity, hydrostatic pressure, and water temperature). However, there are few reports on the effects of exercise in water on muscles, and there is no standard qualitative assessment method for muscle flexibility. Therefore, we used ultrasound real-time tissue elastography (RTE) to compare muscle hardness after water-walking and land-walking. Participants were 15 healthy young adult males (24.8 ± 2.3 years). The method consisted of land-walking and water-walking for 20 min on separate days. The strain ratio of the rectus femoris (RF) and medial head of gastrocnemius (MHGM) muscles were measured before and immediately after walking using RTE to evaluate muscle hardness. In water-walking, the strain ratio significantly decreased immediately after water-walking, with p < 0.01 for RF and p < 0.05 for MHGM, indicating a significant decrease in muscle hardness after water-walking. On the other hand, land-walking did not produce significant differences in RF and MHGM. Muscle hardness after aerobic exercise, as assessed by RTE, was not changed by land walking but was significantly decreased by water walking. The decrease in muscle hardness induced by water-walking was thought to be caused by the edema reduction effect produced by buoyancy and hydrostatic pressure.
Collapse
|
6
|
Gervasi M, Benelli P, Venerandi R, Fernández-Peña E. Relationship between Muscle-Tendon Stiffness and Drop Jump Performance in Young Male Basketball Players during Developmental Stages. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:17017. [PMID: 36554895 PMCID: PMC9778993 DOI: 10.3390/ijerph192417017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 12/14/2022] [Accepted: 12/15/2022] [Indexed: 06/17/2023]
Abstract
BACKGROUND The relationship between stiffness and drop jump performance in athletes in various stages of development has yet to be fully investigated. The first aim of this study was to investigate the association between the stiffness of the patellar and quadriceps tendon (PT, QT), gastrocnemius-Achilles tendon unit (GAT), and rectus femoris (RF) using drop jump (DJ) performance in young basketball players. The second aim was to investigate possible variations in the stiffness levels of those tissues in different developmental stages. METHODS The stiffness levels of the GAT, PT, QT, and RF were measured in both limbs in 73 male basketball players aged 12 to 18 years. The reactive strength index (RSI), contact time (CT) and jump height (JH) during 30 and 40 cm DJs were also measured. RESULTS Pearson correlation coefficients showed a significant association between DJ performance and PT, QT, GAT, and RF dynamic stiffness. Moreover, the youngest subjects were found to have lower stiffness values than the older ones. CONCLUSIONS Tissue stiffness can affect athletic performance by modifying the stretch-shortening cycle in young basketball players. Stiffness of muscles and tendons increases during the maturation process. Further investigations could shed light on the effect of training on the stiffness of muscles and tendons.
Collapse
Affiliation(s)
- Marco Gervasi
- Department of Biomolecular Sciences, Division of Exercise and Health Sciences, University of Urbino Carlo Bo, 61029 Urbino, Italy
| | - Piero Benelli
- Department of Biomolecular Sciences, Division of Exercise and Health Sciences, University of Urbino Carlo Bo, 61029 Urbino, Italy
- US Victoria Libertas Basketball, 61122 Pesaro, Italy
| | | | - Eneko Fernández-Peña
- Department of Physical Education and Sport, University of the Basque Country UPV/EHU, 01007 Vitoria-Gasteiz, Spain
| |
Collapse
|
7
|
TECAR Therapy Associated with High-Intensity Laser Therapy (Hilt) and Manual Therapy in the Treatment of Muscle Disorders: A Literature Review on the Theorised Effects Supporting Their Use. J Clin Med 2022; 11:jcm11206149. [PMID: 36294470 PMCID: PMC9604865 DOI: 10.3390/jcm11206149] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 10/14/2022] [Accepted: 10/17/2022] [Indexed: 11/17/2022] Open
Abstract
Background: It has been estimated that between 30 and 50 per cent of all injuries that take place throughout participation in a sport are the consequence of soft tissue injuries, and muscle injuries are the primary cause of physical disability. Methods: The current literature review was designed between October 2021 and April 2022, according to the PRISMA standards, using the PubMed, Scopus, and Web of Science databases. At the screening stage, we eliminated articles that did not fit into the themes developed in all subchapters of the study (n = 70), articles that dealt exclusively with orthopaedics (n = 34), 29 articles because the articles had only the abstract visible, and 17 articles that dealt exclusively with other techniques for the treatment of musculoskeletal disorders. The initial search revealed 343 titles in the databases, from which 56 duplicate articles were automatically removed, and 2 were added from other sources. Results: The combination of these three techniques results in the following advantages: It increases joint mobility, especially in stiff joints, it increases the range of motion, accelerates tissue repair, improves tissue stability, and extensibility, and it reduces soft tissue inflammation (manual therapy). In addition, it decreases the concentration of pro-inflammatory mediators and improves capillary permeability, resulting in the total eradication of inflammation (HILT). It warms the deep tissues, stimulates vascularity, promotes the repose of tissues (particularly muscle tissue), and stimulates drainage (TECAR). Conclusions: TECAR therapy, combined with manual therapy and High-Intensity Laser therapy in treating muscle diseases, presented optimal collaboration in the recovery process of all muscle diseases.
Collapse
|
8
|
Wei HQ, Gan M, Li GY, Ma SH, Liu JH. Quantitative Evaluation of Biceps Brachii Muscle by Shear Wave Elastography in Stroke Patients. Ther Clin Risk Manag 2022; 18:879-887. [PMID: 36212049 PMCID: PMC9541677 DOI: 10.2147/tcrm.s361664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Accepted: 07/11/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose The present study aimed to investigate the differences in muscle size and shear wave speed (SWS) values of biceps brachii muscle (BBM) between stroke survivors and healthy controls. Methods This study comprised 61 stroke survivors and 24 healthy subjects, examined at Guangzhou First People's Hospital within one year. Each participant underwent ultrasonic examinations for recording some specific measurement indicators, including muscle thickness, cross-sectional area (CSA), and shear wave speed (SWS) of BBM. The muscular tension of the paretic arm was scored using the modified Ashworth scale (MAS). These above-mentioned indexes were compared between stroke survivors and healthy controls. Also, the correlations among SWS and MAS scores were assessed. Results When the lifting arm angle was set for 45°, the CSA and muscle thickness of BBM were obviously decreased in the paretic arms of stroke subjects compared to the non-paretic arms as well as the arms of healthy controls. Moreover, the paretic arms had obviously higher SWS than the non-paretic arms and the healthy arms at 45° or 90°. When the angles of paretic arms were lifted at 90° and 45°, respectively, a positive correlation was established between MAS and SWS. Conclusion Ultrasonic examination assessing muscle thickness, CSA, and SWS of the BBM could be used as a means of assessment of the paretic arms of stroke survivors.
Collapse
Affiliation(s)
- Hong-Qin Wei
- Department of Ultrasound, Guangzhou First People’s Hospital, Guangzhou, Guandong, People’s Republic of China
| | - Man Gan
- Department of Ultrasound, Guangzhou First People’s Hospital, Guangzhou, Guandong, People’s Republic of China
| | - Guo-Yan Li
- Department of Rehabilitation Medicine, Guangzhou First People’s Hospital, Guangzhou, Guandong, People’s Republic of China
| | - Sui-Hong Ma
- Department of Ultrasound, Guangzhou First People’s Hospital, Guangzhou, Guandong, People’s Republic of China,Correspondence: Sui-Hong Ma; Jian-Hua Liu, Tel +86 13824420620; +86 13622888381, Fax +86 020 81332620, Email ;
| | - Jian-Hua Liu
- Department of Ultrasound, Guangzhou First People’s Hospital, Guangzhou, Guandong, People’s Republic of China
| |
Collapse
|
9
|
Ustabaşıoğlu FE, Ağırdemir FE, Ustabaşıoğlu F, Sunal BS. Acute effect of resistance exercise at different velocities on stiffness and vascularity of the biceps brachii muscle: a preliminary study. Acta Radiol 2022; 64:1500-1507. [PMID: 36112819 DOI: 10.1177/02841851221125380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background Resistance exercise can be defined as the percentage of maximal strength (%1 repetition maximum) used for a particular exercise. Shear wave elastography (SWE) is a robust and novelty imaging technique that provides information regarding tissue stiffness. Superb microvascular imaging (SMI) is a non-irradiating technique that can provide quantitative measurement of muscle blood flow non-invasively. Purpose To compare the acute effects of low- and high-velocity resistance exercise on stiffness and blood flow in the biceps brachii muscle (BBM) using SWE and SMI. Material and Methods This prospective study included 60 healthy men (mean age=28.9 years; age range=26–34 years). BBM stiffness was measured by using SWE at rest, after low- and high-velocity resistance exercise, and muscle blood flow was also evaluated by SMI. Resistance exercise was performed using a dumbbell with a mass adjusted to 70%–80% of one-repetition maximum. Results The stiffness values increased significantly from resting to high- and low-velocity resistance exercises. There was no significant difference between the elastography values of the BBM after the high- and low-velocity resistance exercise. The blood flow increased significantly from resting to high- and low-velocity resistance exercises. Blood flow increase after low-velocity exercise was significantly higher compared to high-velocity exercise. Conclusion While muscle stiffness parameters and blood flow significantly increased from resting after both high- and low-velocity resistance exercises, blood flow significantly increased after low-velocity exercise compared to high-velocity exercise. This can mean that metabolic stress, an important trigger for muscle development, is more likely to occur in low-velocity exercise.
Collapse
Affiliation(s)
| | - Fatma Ebru Ağırdemir
- Department of Sports Medicine, Edirne Sultan 1st Murat State Hospital, Edirne, Turkey
| | - Fatma Ustabaşıoğlu
- Department of Physical Medicine and Rehabilitation, Edirne Sultan 1st Murat State Hospital, Edirne, Turkey
| | - Baran Serdar Sunal
- Department of Radiology, Trakya University Faculty of Medicine, Edirne, Turkey
| |
Collapse
|
10
|
Shear-Wave Elastography and Viscosity PLUS for the Assessment of Peripheric Muscles in Healthy Subjects: A Pre- and Post-Contraction Study. Diagnostics (Basel) 2022; 12:diagnostics12092138. [PMID: 36140536 PMCID: PMC9497738 DOI: 10.3390/diagnostics12092138] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 08/24/2022] [Accepted: 08/30/2022] [Indexed: 12/31/2022] Open
Abstract
Viscosity is a novel parameter, recently introduced in the use of elastographic techniques, correlating to shear-wave dispersion. The purpose of this study was to provide normal reference viscosity values for the peripheral muscles in healthy volunteers. This prospective study included 38 subjects who underwent US examinations between November 2021 and January 2022. Measurements were taken on the calf and the deltoid muscles in both pre- and post-contraction states. The age range was 21–29 years, with a median of 26 years. The SWE and ViPLUS values in the deltoid muscles were significantly higher than in the soleus muscles in both pre- and post-contraction sets (p = 0.002). There were statistically significant differences between the pre- and post-contraction values for both the SWE and ViPLUS values in the subgroup analysis. The ICC estimates and the 95% confidence intervals were based on a mean rating (k = 2), an absolute agreement, and a two-way random-effects model, demonstrating excellent agreement between the measurements taken by the two examiners.
Collapse
|
11
|
Nakagawa K, Kataoka H, Murata C, Goto K, Yamashita J, Honda Y, Sakamoto J, Origuchi T, Okita M. Relationship Between Muscle Quality or Stiffness Measured by Ultrasonography and Range of Motion in Hospitalized Older Adults. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1858-1866. [PMID: 35717351 DOI: 10.1016/j.ultrasmedbio.2022.05.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 03/24/2022] [Accepted: 05/11/2022] [Indexed: 06/15/2023]
Abstract
Older adults who require nursing care have joint contractures characterized by limited range of motion (ROM). The present study investigated age-related muscle changes using ultrasonography and the relationship between ROM and muscle changes in older adults. Twenty-two healthy young adults (mean age: 23.3 y) and 60 hospitalized older adults (mean age: 86.1 y) participated. ROM of hip abduction was measured using a goniometer. Echo intensity (EI), reflecting interstitial fibrous tissue or fat within adductor longus (ADDl) was measured using B-mode ultrasonography, and strain ratio (SR), reflecting ADDl stiffness, was measured by strain elastography. The Mann-Whitney U-test and Spearman's correlation test were used for analysis. The ROM and SR of older adults were significantly lower than those of young adults (both p values <0.001). The EI was significantly higher in older adults than in young adults (p < 0.001). In older adults, the SR was moderately correlated with ROM (ρ = 0.49, p < 0.001). In conclusion, limited ROM and increase in interstitial fibrous tissue or fat and stiffness occur with aging, and the SR measured by strain elastography is useful for investigating the effect of muscle stiffness on the ROM of hospitalized older adults.
Collapse
Affiliation(s)
- Koichi Nakagawa
- Department of Physical Therapy Science, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan; Department of Rehabilitation, Nagasaki Memorial Hospital, Nagasaki, Japan
| | - Hideki Kataoka
- Department of Physical Therapy Science, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan; Department of Rehabilitation, Nagasaki Memorial Hospital, Nagasaki, Japan
| | - Chiaki Murata
- Department of Rehabilitation, Nagasaki Memorial Hospital, Nagasaki, Japan
| | - Kyo Goto
- Department of Physical Therapy Science, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan; Department of Rehabilitation, Nagasaki Memorial Hospital, Nagasaki, Japan
| | | | - Yuichiro Honda
- Department of Physical Therapy Science, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan; Institute of Biomedical Sciences, Nagasaki University, Nagasaki, Japan
| | - Junya Sakamoto
- Department of Physical Therapy Science, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan; Institute of Biomedical Sciences, Nagasaki University, Nagasaki, Japan
| | - Tomoki Origuchi
- Department of Physical Therapy Science, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan; Institute of Biomedical Sciences, Nagasaki University, Nagasaki, Japan
| | - Minoru Okita
- Department of Physical Therapy Science, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan; Institute of Biomedical Sciences, Nagasaki University, Nagasaki, Japan.
| |
Collapse
|
12
|
Sawada T, Okawara H, Nakashima D, Iwabuchi S, Matsumoto M, Nakamura M, Nagura T. Effects of alternating heat and cold stimulation at different cooling rates using a wearable thermo device on shoulder muscle stiffness: a cross-over study. BMC Musculoskelet Disord 2022; 23:669. [PMID: 35831832 PMCID: PMC9281090 DOI: 10.1186/s12891-022-05623-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 07/05/2022] [Indexed: 11/10/2022] Open
Abstract
Background A small, wearable thermo device that uses Peltier elements for programmed heat and cold stimulation has been developed recently and is expected to be applied in conventional contrast bath therapy. This study was aimed to examine improvements in trapezius muscle hardness and subjective symptoms resulting from alternating heat and cold stimulation, with different rates of cooling. Methods This cross-over study included four conditions. Twenty healthy young male individuals (age, 22.3 ± 4.5 years) participated in this study. These four interventions targeted the unilateral trapezius muscle of the dominant arm after a 15-min typing task. Specifically, heat and cold stimulations were applied at different ratios (the heating/cooling rate of 3:1, 3:2, and 3:3) or not applied. Each intervention was separated by at least one week. Skin temperature at the stimulation area was recorded using a data logger. Outcome measures included muscle hardness (measured using a portable tester) and subjective symptoms (muscle stiffness and fatigue). Each item was assessed at three time points: baseline, after typing, and after the intervention. Results Two-way analysis of variance with repeated measures found an interaction effect for muscle hardness between four conditions (3:1, 3:2, 3:3, and no) and three time points (p < 0.05). Only in the 3:1 condition were the post-intervention values lower than those after typing (p < 0.01). There was also an interaction effect for subjective muscle stiffness (p < 0.05); the values after the intervention in the 3:1 condition were lower than those after intervention in the no stimulation condition (p < 0.01). There was no significant relationship between changes in muscle hardness and changes in subjective symptoms in the 3:1 condition. Conclusions Our results demonstrate that alternating heat and cold stimulations with a different cooling rate could affect the degree of improvement in muscle hardness and subjective symptoms. In particular, the 3:1 condition has the possibility to improved muscle hardness within the condition and subjective muscle stiffness between conditions. Trial registration UMIN000040620. Registered 1 June 2020, https://upload.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000046359 Supplementary Information The online version contains supplementary material available at 10.1186/s12891-022-05623-z.
Collapse
Affiliation(s)
- Tomonori Sawada
- Diagnosis and Treatment Division, Nagura Orthopedic Clinic, Chuo, Tokyo, Japan.,Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Hiroki Okawara
- Diagnosis and Treatment Division, Nagura Orthopedic Clinic, Chuo, Tokyo, Japan.,Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Daisuke Nakashima
- Diagnosis and Treatment Division, Nagura Orthopedic Clinic, Chuo, Tokyo, Japan. .,Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan.
| | - Shuhei Iwabuchi
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Morio Matsumoto
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Masaya Nakamura
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Takeo Nagura
- Diagnosis and Treatment Division, Nagura Orthopedic Clinic, Chuo, Tokyo, Japan.,Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan.,Department of Clinical Biomechanics, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| |
Collapse
|
13
|
Habe T, Numano T, Nishijo H, Iwama Y, Takamoto K, Ito D, Mizuhara K, Osada K, Kanai M. Time-course of physical properties of the psoas major muscle after exercise as assessed by MR elastography. Magn Reson Imaging 2022; 92:133-139. [PMID: 35772585 DOI: 10.1016/j.mri.2022.06.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 06/16/2022] [Accepted: 06/23/2022] [Indexed: 11/15/2022]
Abstract
This study aimed to analyze the time-course of the physical properties of the psoas major muscle (PM) before and after exercise using magnetic resonance elastography (MRE). Muscle stiffness is one of the important properties associated with muscle function. However, there was no research on the stiffness of the PM after exercise. In this study, we investigated time-course changes of the shear modulus of the PM after exercise. Furthermore, T2 values and apparent diffusion coefficient (ADC), as the additional information associated with muscular physical properties, were also measured simultaneously. Healthy young male volunteers were recruited in this study (n = 9) and they were required to perform a hand-to-knee isometric and unilateral exercise (left side). At each time-point before and after exercise, a set of 3 types of MR scans to measure multiple physical properties of the PM [shear modulus (MRE), T2 values, and ADC] were repeatedly taken. On day 1, a single set MR scan was taken before exercise (pre-exercise MR scan), and 6 sets MR scans were taken (5.5 to 38.0 min after exercise). After about 10-min rest (46.0 to 56.0 min after exercise), 4 sets MR scans were taken (57.5 to 77.0 min after exercise). About 10-min rest was taken again (85.0-95.0 min after exercise), 4 sets MR scans were taken (96.5 to 116.0 min after exercise). On days 2 and 7, a single set MR scan (MRE, T2 value, and ADC) was taken on each experimental day. The data were analyzed as relative changes (%) of the given parameters to the pre-exercise values. The results indicated significant decreases in PM shear modulus up to about 30 min after exercise. Then, it gradually increased and showed significant increases at about 100 min after exercise compared to that before exercise. T2 values and ADC showed significant increases up to about 65 min after exercise compared to those before exercise, and then returned to the pre-exercise values. On days 2 and 7, all values showed no significant changes compared to the pre-exercise values. This study is the first to report the time-course of the physical properties of the PM after exercise.
Collapse
Affiliation(s)
- Tetsushi Habe
- Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan; Office of Radiation Technology, Keio University Hospital, Tokyo, Japan
| | - Tomokazu Numano
- Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan; Human Technology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Ibaraki, Japan.
| | - Hisao Nishijo
- System Emotional Science, Faculty of Medicine, University of Toyama, Toyama, Japan
| | - Yudai Iwama
- System Emotional Science, Faculty of Medicine, University of Toyama, Toyama, Japan
| | - Kouichi Takamoto
- Department of Sport and Health Sciences, Faculty of Human Sciences, University of East Asia, Yamaguchi, Japan
| | - Daiki Ito
- Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan; Office of Radiation Technology, Keio University Hospital, Tokyo, Japan
| | - Kazuyuki Mizuhara
- Human Technology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Ibaraki, Japan; Department of Mechanical Engineering, Tokyo Denki University, Tokyo, Japan
| | - Kaito Osada
- Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan
| | - Midori Kanai
- Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan
| |
Collapse
|
14
|
Sawada T, Okawara H, Nakashima D, Iwabuchi S, Matsumoto M, Nakamura M, Nagura T. Effects of alternating heat and cold stimulation using a wearable thermo-device on subjective and objective shoulder stiffness. J Physiol Anthropol 2022; 41:1. [PMID: 34980256 PMCID: PMC8722412 DOI: 10.1186/s40101-021-00275-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Accepted: 12/10/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Technological innovations have allowed the use of miniature apparatus that can easily control and program heat and cold stimulations using Peltier elements. The wearable thermo-device has a potential to be applied to conventional contrast bath therapy. This study aimed to examine the effects of alternating heat and cold stimulation (HC) using a wearable thermo-device on subjective and objective improvement of shoulder stiffness. METHODS Twenty healthy young male individuals (20.3 ± 0.6 years) participated in this study. The interventions were randomly conducted under four conditions, including HC, heat stimulation, cold stimulation, and no stimulation on their bilateral trapezius muscle, after a 30-min typing task. Each intervention was administered at least 1 week apart. The analyzed limb was the dominant arm. Muscle hardness was assessed using a portable muscle hardness meter, as well as the skin temperature over the stimulated area. After each condition, the participants were asked for feedback regarding subjective improvement in refreshed feelings, muscle stiffness, and muscle fatigue using an 11-point numerical rating scale. RESULTS With regard to muscle hardness, only the HC condition significantly decreased from 1.43 N to 1.37 N (d = 0.44, p < 0.05). Additionally, reduced muscle hardness in HC condition was associated with the degree of skin cooling during the intervention (cold max: r = 0.634, p < 0.01; cold change: r = -0.548, p < 0.05). Subjective improvement in refreshed feelings, muscle stiffness, and muscle fatigue was determined in the HC and heat stimulation conditions compared with the no stimulation condition (p < 0.01 and p < 0.05, respectively). Moreover, the HC condition showed significantly greater improvements in muscle stiffness and fatigue compared to the cold stimulation condition (p < 0.05). CONCLUSIONS The current study demonstrated that HC promoted not only better subjective symptoms, such as muscle stiffness and fatigue, but also lesser muscle hardness. Furthermore, an association was observed between the degree of skin temperature cooling and reduced muscle hardness during HC. Further investigations on the ratio and intensity of cooling should be conducted in the future to establish the optimal HC protocol for muscle stiffness or fatigue. TRIAL REGISTRATION UMIN000040620 . Registered 1 June 2020.
Collapse
Affiliation(s)
- Tomonori Sawada
- Diagnosis and Treatment Division, Nagura Orthopedic Clinic, Chuo, Tokyo, Japan.,Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Hiroki Okawara
- Diagnosis and Treatment Division, Nagura Orthopedic Clinic, Chuo, Tokyo, Japan.,Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Daisuke Nakashima
- Diagnosis and Treatment Division, Nagura Orthopedic Clinic, Chuo, Tokyo, Japan. .,Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan.
| | - Shuhei Iwabuchi
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Morio Matsumoto
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Masaya Nakamura
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Takeo Nagura
- Diagnosis and Treatment Division, Nagura Orthopedic Clinic, Chuo, Tokyo, Japan.,Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan.,Department of Clinical Biomechanics, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| |
Collapse
|
15
|
Minami Y, Ogura I. Quantitative analysis of masseter muscle hardness with shear-wave elastography: Preliminary study on comparison between during rest and contraction in young adults. JOURNAL OF ORAL AND MAXILLOFACIAL RADIOLOGY 2022. [DOI: 10.4103/jomr.jomr_3_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
16
|
Wachi M, Jiroumaru T, Satonaka A, Ikeya M, Noguchi S, Suzuki M, Hyodo Y, Oka Y, Fujikawa T. Effects of capacitive and resistive electric transfer therapy on pain and lumbar muscle stiffness and activity in patients with chronic low back pain. J Phys Ther Sci 2022; 34:400-403. [PMID: 35527841 PMCID: PMC9057676 DOI: 10.1589/jpts.34.400] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 02/13/2022] [Indexed: 11/24/2022] Open
Abstract
[Purpose] In this study, we investigated the therapeutic effects of capacitive and
resistive electric transfer therapy in patients with chronic low back pain. [Participants
and Methods] The study included 24 patients with chronic low back pain (12 patients each
in the intervention and sham groups). Pain intensity, superficial and deep lumbar
multifidus stiffness and maximum forward trunk flexion and associated activation level of
the iliocostalis (thoracic and lumbar component) and lumbar multifidus muscles were
measured. [Results] Post-intervention pain intensity and muscle stiffness were
significantly lower than pre-intervention measurements in the intervention group. However,
no between-group difference was observed in the muscle activation level at the end-point
of standing trunk flexion. [Conclusion] Our findings highlight a significant therapeutic
benefit of capacitive and resistive electric transfer therapy in patients with chronic low
back pain and muscle stiffness.
Collapse
Affiliation(s)
- Michio Wachi
- Department of Physical Therapy, Biwako Professional University of Rehabilitation: 967 Kitasaka-cho, Higashiomi City, Shiga 527-0145, Japan
| | | | - Ayako Satonaka
- Department of Physical Therapy, Biwako Professional University of Rehabilitation: 967 Kitasaka-cho, Higashiomi City, Shiga 527-0145, Japan
| | - Masae Ikeya
- Department of Applied Biology, Kyoto Institute of Technology, Japan
| | - Shinichi Noguchi
- Department of Physical Therapy, Biwako Professional University of Rehabilitation: 967 Kitasaka-cho, Higashiomi City, Shiga 527-0145, Japan
| | - Mika Suzuki
- Department of Physical Therapy, Biwako Professional University of Rehabilitation: 967 Kitasaka-cho, Higashiomi City, Shiga 527-0145, Japan
| | - Yutaro Hyodo
- Department of Applied Biology, Kyoto Institute of Technology, Japan
| | - Yasumasa Oka
- Department of Applied Biology, Kyoto Institute of Technology, Japan
| | | |
Collapse
|
17
|
Sasadai J, Maeda N, Sakai S, Tashiro T, Arima H, Urabe Y. Effect of a 4-week static stretching program for plantar flexor muscles on physical performance and muscle properties. ISOKINET EXERC SCI 2021. [DOI: 10.3233/ies-210133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND: The effects of a long-term static stretching program on physical performance parameters have not been elucidated completely, although the effects on muscle flexibility have a consensus. OBJECTIVE: This study aimed to investigate the effect of a long-term static stretching program on physical performance and muscle properties. METHODS: Participants performed a 2-min static stretching for the ankle joint 5 times per week for 4 weeks. Physical performance and muscle properties was measured before and after the static stretching program. RESULTS: Results showed that range of motion (ROM), dynamic postural stability, and muscle hardness were positively changed, whereas other variables i.e. maximal isometric plantar flexion moment, jump heights, muscle-tendon junction displacement and its angle, were not. CONCLUSIONS: Four-week of SS program may improve ROM, dynamic postural stability, and muscle hardness without decreasing physical performance.
Collapse
Affiliation(s)
- Junpei Sasadai
- Sports Medical Center, Japan Institute of Sports Sciences, Tokyo, Japan
| | - Noriaki Maeda
- Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Shogo Sakai
- Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Tsubasa Tashiro
- Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Hitoshi Arima
- Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Yukio Urabe
- Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
18
|
Beydoğan E, Yalçın A. Is 2D SWE sufficient as clinical diagnosis in patients with plantar fasciitis? Acta Radiol 2021; 64:147-152. [PMID: 34851153 DOI: 10.1177/02841851211058928] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
BACKGROUND The use of shear wave elastography (SWE) seems to be an important imaging method in the diagnosis of plantar fasciitis (PF). PURPOSE To compare patients diagnosed with PF with similar and young healthy control groups in terms of B-mode ultrasound (US) and SWE results and to evaluate the elasticity of the plantar fascia. MATERIAL AND METHODS A total of 140 feet of 70 participants were evaluated, including 30 patients and 40 healthy individuals as the control. Clinical, B-mode US, and SWE evaluations were performed for each patient. In addition, American Orthopedic Foot and Ankle Score (AOFAS) was calculated to evaluate pain and foot function in both groups. RESULTS Of the patients in the PF group, 40 (88%) were women and the healthy control groups had similar sex distributions (P = 0.23). The AOFAS score was lower in feet with PF compared to the other groups (P < 0.001). Of 30 patients with PF, 15 (50%) had bilateral PF and 15 (50%) unilateral PF. In addition, ≥4 mm thickness measurement, which was used as a diagnostic criterion for PF as a US finding, could be shown in 11 (73.3%) patients with unilateral PF and 6 (40%) patients with bilateral PF. CONCLUSION In conclusion, the evaluation of the diagnosis of PF with clinical findings and regular follow-up of measurements with SWE can provide measurement results with higher sensitivity in the diagnosis of PF.
Collapse
Affiliation(s)
- Engin Beydoğan
- Van Research and Training Hospital, Department of Radiology, Van, Turkey
| | - Atilla Yalçın
- Taksim Research and Training Hospital, Department of Orthopedics and Traumatology, Istanbul, Turkey
| |
Collapse
|
19
|
Maeda N, Hirota A, Komiya M, Morikawa M, Mizuta R, Fujishita H, Nishikawa Y, Kobayashi T, Urabe Y. Intrinsic foot muscle hardness is related to dynamic postural stability after landing in healthy young men. Gait Posture 2021; 86:192-198. [PMID: 33756408 DOI: 10.1016/j.gaitpost.2021.03.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 01/28/2021] [Accepted: 03/03/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND The human foot has competent mechanisms for supporting weight and adapting movement to various surfaces; in particular, the toe flexor muscles aid in supporting the foot arches and may be important contributors to postural stability. However, the role of intrinsic foot muscle morphology and structure in the postural control system remains unclear, and the relationship between them is not well known. RESEARCH QUESTION Are intrinsic foot muscle morphology and toe flexor strength related to static and dynamic postural stability in healthy young men?. METHODS A total of 27 healthy men aged 19-27 years participated in this study. intrinsic foot muscle morphology included muscle hardness and thickness. Cross-sectional area was measured by ultrasonography at an ankle dorsiflexion angle of 0°. The hardness of the abductor hallucis (AbH), flexor hallucis brevis, and flexor digitorum brevis (FDB) muscles was measured using ultrasound real-time tissue elastography. Static postural stability during single-leg standing on a single force platform with closed eyes was assessed for the right leg. In the assessment of dynamic postural stability, the subjects jumped and landed on single-leg onto a force platform and the dynamic postural stability index (DPSI) was measured. RESULTS FDB muscle thickness showed a positive correlation with anteroposterior stability index (APSI) (r = 0.398, p = 0.040). AbH muscle hardness was negatively correlated with APSI (r = -0.407, p = 0.035); whereas FDB muscle hardness was positively correlated with DPSI (r = 0.534, p = 0.004), vertical stability index (r = 0.545, p = 0.003), and maximum vertical ground reaction force (r = 0.447, p = 0.020). Multiple regression with forced entry revealed that only DPSI was significantly correlated with FDB muscle hardness (p = 0.003). SIGNIFICANCE The results indicated that intrinsic foot muscle hardness plays an important role in dynamic postural control among healthy young men, which may enable a more rapid muscular response to changes in condition during jump landing and better performance in balance tasks.
Collapse
Affiliation(s)
- Noriaki Maeda
- Division of Sport Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8553, Japan.
| | - Arisu Hirota
- Division of Sport Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8553, Japan
| | - Makoto Komiya
- Division of Sport Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8553, Japan
| | - Masanori Morikawa
- Division of Sport Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8553, Japan
| | - Rami Mizuta
- Division of Sport Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8553, Japan
| | - Hironori Fujishita
- Sports Medical Center, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Yuichi Nishikawa
- Faculty of Frontier Engineering, Institute of Science & Engineering, Kanazawa University, Kanazawa, Japan
| | - Toshiki Kobayashi
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, 11 Yuk Choi Road, Hung Hom, Hong Kong, China
| | - Yukio Urabe
- Division of Sport Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8553, Japan
| |
Collapse
|
20
|
Morikawa M, Maeda N, Komiya M, Hirota A, Mizuta R, Kobayashi T, Kaneda K, Nishikawa Y, Urabe Y. Contribution of Plantar Fascia and Intrinsic Foot Muscles in a Single-Leg Drop Landing and Repetitive Rebound Jumps: An Ultrasound-Based Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18094511. [PMID: 33922807 PMCID: PMC8123000 DOI: 10.3390/ijerph18094511] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 04/10/2021] [Accepted: 04/19/2021] [Indexed: 11/16/2022]
Abstract
The plantar fascia and intrinsic foot muscles (IFM) modulate foot stiffness. However, it is unclear whether the corresponding ultrasonography findings reflect it. This study aimed to examine the effect of the plantar fascia and IFM morphologies on force attenuation during landing and reactivity when jumping in healthy adults (n = 21; age, 21-27 years). Thickness, cross-sectional area (CSA), and hardness of the plantar fascia, abductor hallucis (AbH), and flexor hallucis brevis (FHB) muscles were measured using ultrasonography. Single-leg drop landing and repetitive rebound jumping tests assessed the ground reaction force (GRF) and reactive jump index (RJI), respectively. The CSA of FHB was negatively correlated with maximum vertical GRF (r = -0.472, p = 0.031) in the single-leg drop landing test. The CSA of AbH was negatively correlated with contact time (r = -0.478, p = 0.028), and the plantar fascia thickness was positively correlated with jump height (r = 0.615, p = 0.003) and RJI (r = 0.645, p = 0.002) in the repetitive bound jump test. In multivariate regression analysis, only the plantar fascia thickness was associated with RJI (β = 0.152, 95% confidence interval: 7.219-38.743, p = 0.007). The CSA of FHB may contribute to force attenuation during landing. The thickness of the plantar fascia and CSA of AbH may facilitate jumping high with minimal contact time.
Collapse
Affiliation(s)
- Masanori Morikawa
- Division of Sport Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8553, Japan; (M.M.); (N.M.); (M.K.); (A.H.); (R.M.); (K.K.)
| | - Noriaki Maeda
- Division of Sport Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8553, Japan; (M.M.); (N.M.); (M.K.); (A.H.); (R.M.); (K.K.)
| | - Makoto Komiya
- Division of Sport Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8553, Japan; (M.M.); (N.M.); (M.K.); (A.H.); (R.M.); (K.K.)
| | - Arisu Hirota
- Division of Sport Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8553, Japan; (M.M.); (N.M.); (M.K.); (A.H.); (R.M.); (K.K.)
| | - Rami Mizuta
- Division of Sport Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8553, Japan; (M.M.); (N.M.); (M.K.); (A.H.); (R.M.); (K.K.)
| | - Toshiki Kobayashi
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, 11 Yuk Choi Road, Hung Hom, Hong Kong, China;
| | - Kazuki Kaneda
- Division of Sport Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8553, Japan; (M.M.); (N.M.); (M.K.); (A.H.); (R.M.); (K.K.)
| | - Yuichi Nishikawa
- Faculty of Frontier Engineering, Institute of Science & Engineering, Kanazawa University, Kanazawa 076-264-5111, Japan;
| | - Yukio Urabe
- Division of Sport Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8553, Japan; (M.M.); (N.M.); (M.K.); (A.H.); (R.M.); (K.K.)
- Correspondence:
| |
Collapse
|
21
|
Schneebeli A, Fiorina I, Bortolotto C, Barbero M, Falla D, Cescon C, Raciti MV, Tarantino F, Preda L. Shear wave and strain sonoelastography for the evaluation of the Achilles tendon during isometric contractions. Insights Imaging 2021; 12:26. [PMID: 33598763 PMCID: PMC7889779 DOI: 10.1186/s13244-021-00974-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Accepted: 02/03/2021] [Indexed: 02/06/2023] Open
Abstract
Objectives Changes in mechanical loading as well as pathology can modify the Achilles tendon mechanical properties and therefore detection of these changes is relevant for the diagnosis and management of Achilles tendinopathy. The aim of this study was to evaluate strain and shear wave sonoelastography for their ability to detect changes in the Achilles tendon mechanical properties during a series of isometric contractions. Methods Longitudinal sonoelastography images of the Achilles tendon were acquired from 20 healthy participants using four different ultrasound devices; two implementing strain sonoelastography technology (SE1, SE2) and two, shear wave elastography technology (SWE1, SWE2). Results SE1 measured a decreasing strain ratio (tendon become harder) during the different contraction levels from 1.51 (0.92) to 0.33 (0.16) whereas SE2 mesaured a decreasing strain ratio from 1.08 (0.76) to 0.50 (0.32). SWE1 measured decreasing tendon stiffness during contractions of increasing intensity from 33.40 (19.61) to 16.19 (2.68) whereas SWE2 revealed increasing tendon stiffness between the first two contraction levels from 428.65 (131.5) kPa to 487.9 (121.5) kPa followed by decreasing stiffness for the higher contraction levels from 459.35 (113.48) kPa to 293.5 (91.18) kPa. Conclusions Strain elastography used with a reference material was able to detect elasticity changes between the different contraction levels whereas shear wave elastography was less able to detect changes in Achilles tendon stiffness when under load. Inconsistent results between the two technologies should be further investigated. Supplementary Information The online version contains supplementary material available at 10.1186/s13244-021-00974-y.
Collapse
Affiliation(s)
- Alessandro Schneebeli
- Centre of Precision Rehabilitation for Spinal Pain (CPR Spine), School of Sport, Exercise and Rehabilitation Sciences, College of Life and Environmental Sciences, University of Birmingham, Birmingham, UK. .,Rehabilitation Research Laboratory 2rLab, Department of Business Economics, Health and Social Care, University of Applied Sciences and Arts of Southern Switzerland, SUPSI, Manno/Landquart, Switzerland.
| | - Ilaria Fiorina
- Dipartimento di radiologia, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
| | - Chandra Bortolotto
- Dipartimento di radiologia, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
| | - Marco Barbero
- Rehabilitation Research Laboratory 2rLab, Department of Business Economics, Health and Social Care, University of Applied Sciences and Arts of Southern Switzerland, SUPSI, Manno/Landquart, Switzerland
| | - Deborah Falla
- Centre of Precision Rehabilitation for Spinal Pain (CPR Spine), School of Sport, Exercise and Rehabilitation Sciences, College of Life and Environmental Sciences, University of Birmingham, Birmingham, UK
| | - Corrado Cescon
- Rehabilitation Research Laboratory 2rLab, Department of Business Economics, Health and Social Care, University of Applied Sciences and Arts of Southern Switzerland, SUPSI, Manno/Landquart, Switzerland
| | | | - Francesco Tarantino
- Dipartimento di radiologia, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
| | - Lorenzo Preda
- Dipartimento di radiologia, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
| |
Collapse
|
22
|
Reliability of Trapezius Muscle Hardness Measurement: A Comparison between Portable Muscle Hardness Meter and Ultrasound Strain Elastography. SENSORS 2020; 20:s20247200. [PMID: 33339151 PMCID: PMC7765603 DOI: 10.3390/s20247200] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 12/11/2020] [Accepted: 12/14/2020] [Indexed: 12/17/2022]
Abstract
Prolonged computer work and smartphone use can cause stiffness of the neck and shoulder muscles, including the trapezius muscle. Hence, muscle hardness quantification is clinically beneficial. The present study aimed to examine the reliability of trapezius muscle hardness measurement using a portable muscle hardness meter and ultrasound strain elastography. Overall, 20 healthy young men participated in this study. Prior to measurement, the participant’s subjective symptoms, particularly shoulder muscle stiffness, were rated using an 11-point verbal scale. Furthermore, hardness of the right and left upper trapezius muscles was assessed. In the strain elastography assessment, muscle hardness was evaluated using strain ratio. Results showed that, in quantifying upper trapezius muscle hardness, both portable muscle hardness meter and strain elastography had an excellent intra-tester reliability (>0.9). However, the correlation coefficients between muscle hardness values assessed using a muscle hardness meter and those evaluated with strain elastography did not significantly differ, and the scores for subjective shoulder stiffness did not correspond to muscle hardness values. Therefore, the hardness of the trapezius muscle does not directly reflect the subjective shoulder stiffness. Future studies should thoroughly examine the location of the shoulder stiffness, and check whether it is accompanied by local pain or tenderness.
Collapse
|
23
|
Blicharz G, Rymarczyk M, Rogulski M, Linek P. Methods of Masseter and Temporal Muscle Thickness and Elasticity Measurements by Ultrasound Imaging: A Literature Review. Curr Med Imaging 2020; 17:707-713. [PMID: 33319689 DOI: 10.2174/1573405616666201214121557] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2020] [Revised: 10/01/2020] [Accepted: 10/14/2020] [Indexed: 11/22/2022]
Abstract
BACKGROUND The positive correlation between changes in the morphology of masseter and temporal muscles and some disorders, inclines diagnosticians to search for an effective method of assessing muscle thickness and elasticity. Ultrasound imaging, as a relatively simple and cheap method, seems to be a useful diagnostic tool. OBJECTIVE The aim of this study was to present the existing ultrasound imaging methods in the assessment of the elasticity and thickness of the masseter and temporal muscles. METHODS The literature review has been done with a focus on the accurate description of the masseter and/or temporal muscle examination by ultrasonography imaging methods. Articles were categorized into two groups. The first group included articles in which muscle thickness was assessed by ultrasound imaging. The second group concerned the elasticity aspect of mentioned muscles. RESULTS It is difficult to achieve an objective protocol of masseter and temporal thickness assessment by ultrasonography and there is no method that has been fully verified in terms of reliability. The shear-wave sonoelastography revealed higher-level reliability of masseter muscle elasticity than strain sonoelastography. During the shear-wave sonoelastography, the effect of scan plane in relation to masseter muscle pennation and the day-to-day variation were statistically significant. With regard to elasticity of temporal muscle, further research is needed. CONCLUSION This review has shown that there is a limited number of methods for masseter and temporal muscle thickness and elasticity measurements by ultrasonography. All procedures (methods) were not fully verified in terms of reliability and agreement. Thus, it is still necessary to develop standardized procures to assess thickness and elasticity of the masseter and temporal muscles with appropriate reliability and accuracy.
Collapse
Affiliation(s)
- Gabriela Blicharz
- Department of Cranio-Maxillo-Facial Surgery Unit, School of Medicine with The Division of Dentistry in Zabrze, Katowice, Poland
| | - Małgorzata Rymarczyk
- Department of Cranio-Maxillo-Facial Surgery Unit, School of Medicine with The Division of Dentistry in Zabrze, Katowice, Poland
| | - Mateusz Rogulski
- Department of Cranio-Maxillo-Facial Surgery Unit, School of Medicine with The Division of Dentistry in Zabrze, Katowice, Poland
| | - Paweł Linek
- Musculoskeletal Elastography and Ultrasonography Laboratory, Institute of Physiotherapy and Health Sciences, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland
| |
Collapse
|
24
|
A Comparison Study of Conventional Ultrasound and Ultrasound Strain Elastography in the Evaluation of Myopathy. Ultrasound Q 2020; 36:32-37. [PMID: 30855416 DOI: 10.1097/ruq.0000000000000432] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The aim of this study was to compare ultrasound strain elastography (USE) with conventional ultrasonography echogenicity (EL) in detecting muscle pathology. For conventional ultrasonography, biceps EL was obtained. For USE, elasticity index (EI) of biceps was represented as a range, from 0 (softest) to 6 (hardest). Muscle-to-fats elasticity ratio compared EI of muscle with that of surrounding fats. Color distribution of elastogram was analyzed using open-source ImageJ software showing % red, % green, and % blue within a region of interest. Increased biceps EL, decreased biceps EI, and elasticity ratio were observed in patients with myopathy. In the color elastogram, there is no significant difference in % green between healthy control and patient, but significance was observed in % red and % blue (P < 0.001). Utilization of USE parameters has increased sensitivity up to 100% compared with 63% with conventional US. It is a promising adjunct for the clinical diagnosis of myopathy.
Collapse
|
25
|
Biceps brachii muscle hardness assessed by a push-in meter in comparison to ultrasound strain elastography. Sci Rep 2020; 10:20308. [PMID: 33219272 PMCID: PMC7680096 DOI: 10.1038/s41598-020-77330-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Accepted: 11/09/2020] [Indexed: 11/09/2022] Open
Abstract
This study investigated the relationship between push-in meter (PM) and ultrasound strain elastography (USE) for biceps brachii (BB) muscle hardness. BB hardness of 21 young men was assessed by PM and USE during rest and isometric contractions of six different intensities (15, 30, 45, 60, 75, 90% of maximal voluntary contraction: MVC) at 30°, 60° and 90° elbow flexion. Muscle hardness (E) was calculated from the force-displacement relationship in PM, and strain ratio (SR) between an acoustic coupler (elastic modulus: 22.6 kPa) and different regions of interest (ROIs) in BB was calculated and converted to Young's modulus (YM) in USE. In resting muscle, E was 26.1 ± 6.4 kPa, and SR and YM for the whole BB was 0.88 ± 0.4 and 30.8 ± 12.8 kPa, respectively. A significant (p < 0.01) correlation was evident between E and logarithmical transformed SR (LTSR) for the ROI of whole BB (r = - 0.626), and E and converted YM (r = 0.615). E increased approximately ninefold from resting to 90% MVC, and E and LTSR (r = - 0.732 to - 0.880), and E and converted YM for the SR above 0.1 were correlated (r = 0.599-0.768, p < 0.01). These results suggest that muscle hardness values obtained by PM and USE are comparable.
Collapse
|
26
|
Shimoyama D, Shitara H, Hamano N, Ichinose T, Sasaki T, Yamamoto A, Kobayashi T, Tajika T, Takagishi K, Chikuda H. Reliability of shoulder muscle stiffness measurement using strain ultrasound elastography and an acoustic coupler. J Med Ultrason (2001) 2020; 48:91-96. [PMID: 33052492 DOI: 10.1007/s10396-020-01056-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 09/15/2020] [Indexed: 12/17/2022]
Abstract
PURPOSE Abnormal increases in muscle tone can be caused by various musculoskeletal disorders. The objective of this study was to evaluate intratester and intertester reliabilities in measuring the stiffness of the shoulder muscles using strain ultrasound elastography (USE) and an acoustic coupler. METHOD Tissue stiffness was measured in the trapezius muscle and in the supraspinatus muscle of healthy young volunteers. RESULTS The mean strain ratios measured by two experienced shoulder surgeons were significantly higher in the trapezius muscle than in the supraspinatus muscle (P < 0.001). Intratester reliability was rated as moderate to substantial for the trapezius muscle and substantial for the supraspinatus muscle. Intertester reliability was substantial for both muscles, with an intraclass correlation coefficient (2,1) of 0.62 [95% confidence interval (CI) 0.28-0.82] for the trapezius muscle and 0.69 (95% CI 0.40-0.86) for the supraspinatus muscle. CONCLUSIONS We found substantial intratester and intertester reliabilities for the trapezius and supraspinatus muscles, suggesting that USE represents a promising modality for measuring the stiffness of shoulder muscles. However, the clinical application of this method will require the development of a device that can standardize the scanning technique to further increase the reliability.
Collapse
Affiliation(s)
- Daisuke Shimoyama
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Hitoshi Shitara
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan.
| | - Noritaka Hamano
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Tsuyoshi Ichinose
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Tsuyoshi Sasaki
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Atsushi Yamamoto
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Tsutomu Kobayashi
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Tsuyoshi Tajika
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Kenji Takagishi
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Hirotaka Chikuda
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| |
Collapse
|
27
|
Aikawa R, Kishino T, Shibasaki S, Harashima K, Nakajima S, Ohnishi H, Watanabe T. Relationship between trapezius muscle hardness and transverse cervical artery flow in association with neck and upper-back stiffness. Clin Physiol Funct Imaging 2020; 40:385-389. [PMID: 32813906 DOI: 10.1111/cpf.12658] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 07/20/2020] [Accepted: 08/14/2020] [Indexed: 11/26/2022]
Abstract
Neck and upper-back stiffness is a common discomfort encountered occasionally in daily life among otherwise healthy subjects. The pathogenesis of this condition could be attributable to increased tension in muscles such as the trapezius muscle (TM). The transverse cervical artery (TCA) is one of the feeding arteries for the TM, and TCA flow is reportedly related to symptoms of neck and upper-back stiffness. This study quantitatively investigated relationships between TM hardness and TCA hemodynamics as evaluated on Doppler sonography. Questionnaires regarding neck and upper-back stiffness, muscle hardness measurements obtained using a muscle hardness meter and examinations of TCA hemodynamics using Doppler sonography were performed on 55 healthy young adults (25 males, 30 females; mean age, 22 ± 2 years). Subjects displaying neck and upper-back stiffness actually exhibited high muscle hardness (median, 14.0; interquartile range (IQR), 12.9-18.0) compared to those without the symptom (median, 12.0; IQR, 9.9-14.0; p = .002). Peak systolic velocity in the TCA on Doppler sonography was lower in subjects with the symptom (median, 65.1 cm/s; IQR 59.6-72.5 cm/s) than in those without the symptom (median, 72.5 cm/s; IQR 66.5-84.2 cm/s; p = .012). Resistive index in the TCA was high (r2 = .605, p = .014) with increasing TM hardness, particularly among male subjects with the symptom. The present study suggests that high resistance and low blood flow velocity in the TCA could be closely associated with the underlying pathogenesis of neck and upper-back stiffness.
Collapse
Affiliation(s)
- Ritsu Aikawa
- Kyorin University Faculty of Health Sciences, Tokyo, Japan
| | | | | | | | | | | | | |
Collapse
|
28
|
The Effect of Strength Training on Vastus Lateralis' Stiffness: An Ultrasound Quasi-Static Elastography Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17124381. [PMID: 32570845 PMCID: PMC7345821 DOI: 10.3390/ijerph17124381] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 06/15/2020] [Accepted: 06/15/2020] [Indexed: 11/16/2022]
Abstract
Ultrasound imaging allows the evaluation of musculoskeletal morphology and function. Ultrasound elastography can also offer semi-quantitative and/or quantitative assessment of tissue stiffness providing relevant information about adaptations of skeletal muscle mechanical properties. In this study we aimed to explore the feasibility of elastography ultrasound imaging in assessing the effect of strength training on vastus lateralis stiffness. Twenty-eight young male adults were separated in a control (n = 9) and strength-training (n = 20) groups. The strength-training group completed 15 weeks of either concentric (n = 10) or eccentric (n = 10) isokinetic training of the knee extensors. Ultrasound scans of the vastus lateralis for quasi-static elastography were collected. All image acquisitions and measurements were done by the same experienced sonographer. After 15 weeks, knee maximal extension isometric torque increased in the strength-training groups. After strength training, there was a decrease in the amount of red pixels in vastus lateralis region of interest [F(1,18) = 25.490; p < 0.001; η2 = 0.586], whereas the amount of green and blue pixels increased F(1,18) = 17.179; p < 0.01; η2 = 0.488; F(1,18) = 6.522; p < 0.05; η2 = 0.266], suggesting higher vastus lateralis stiffness. We conclude that concentric and eccentric strength training increases skeletal muscle stiffness, which can be evaluated by quasi-static elastography. Ultrasound elastography is suitable for non-invasive evaluation of skeletal muscle functional adaptations, which can be of importance for sports medicine and in designing optimal training and rehabilitation programs.
Collapse
|
29
|
Dankel SJ, Razzano BM. The impact of acute and chronic resistance exercise on muscle stiffness: a systematic review and meta-analysis. J Ultrasound 2020; 23:473-480. [PMID: 32533552 DOI: 10.1007/s40477-020-00486-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Accepted: 05/25/2020] [Indexed: 12/17/2022] Open
Abstract
PURPOSE Ultrasound is commonly used to measure changes in skeletal muscle morphology in response to both acute and chronic resistance exercise, but little is known on how muscle stiffness changes via ultrasound elastography, which was the purpose of this systematic review and meta-analysis. METHODS The online data bases of Pubmed, Scopus, and Web of Science were each searched up until February 2020 and the data were analyzed using a random effects model. RESULTS A total of eight studies (four acute and four chronic) met the inclusion criteria for the quantitative analysis. Following a single bout of exercise, muscle stiffness was increased within the first hour [ES: 1.52 (95% CI 0.14, 2.91); p = 0.031], but was no longer elevated when measured 2 days post-exercise [ES: 0.76 (95% CI - 0.32, 1.83); p = 0.16] or ≥ 7 days post-exercise [ES: 0.20 (95% CI - 0.53, 0.94); p = 0.58]. There was no impact of long-term resistance training on changes in muscle stiffness [ES: - 0.04 (95% CI - 0.24, 0.15); p = 0.653]. CONCLUSION The primary findings from this meta-analysis indicate that muscle stiffness increases acutely following a single bout of resistance exercise, but does not change long-term with chronic resistance training when measured via ultrasound shear elastography. Given the small number of studies included in this review, future studies may wish to examine changes in muscle stiffness in response to both acute and chronic resistance exercise.
Collapse
Affiliation(s)
- Scott Justin Dankel
- Department of Health and Exercise Science, Rowan University, Glassboro, New Jersey, United States.
| | - Brenna M Razzano
- Department of Health and Exercise Science, Rowan University, Glassboro, New Jersey, United States
| |
Collapse
|
30
|
The Passive Mechanical Properties of Muscles and Tendons in Children Affected by Osgood-Schlatter Disease. J Pediatr Orthop 2020; 40:e243-e247. [PMID: 31343463 DOI: 10.1097/bpo.0000000000001426] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Osgood-Schlatter disease (OSD) is a sports-related disorder involving apophysitis, which affects the tibial tuberosity. The identification of factors related to OSD is important for its prevention and early recovery from the disease. This study aimed to compare the passive mechanical properties of the muscle-tendon unit in children affected by an OSD and healthy children, by using ultrasound real-time tissue elastography. METHODS Eighteen legs affected by OSD (OSD group) and 42 healthy legs (control: CON group) were assessed. The elasticity was obtained from the quadriceps muscles and patella tendon (PT) using real-time tissue elastography. The strain ratio (SR; muscle or tendon/reference ratio: strain rate of the muscle or tendon divided by that of the reference material) was calculated as an indicator of the elasticity of the tissue of interest. RESULTS The SR of the PT in the OSD group was significantly lower than that in the CON group (P<0.05). We found no significant difference between the groups in terms of the SR value of all muscles (P>0.05). CONCLUSIONS The results suggest that a PT with a lower SR may be associated with an OSD and that the passive mechanical properties of the quadriceps muscles have limited association with an OSD. LEVELS OF EVIDENCE Level IV.
Collapse
|
31
|
Alsiri N, Al-Obaidi S, Asbeutah A, Palmer S. Intra-rater reliability and smallest detectable change of compression sonoelastography in quantifying the material properties of the musculoskeletal system. J Anat 2020; 237:74-84. [PMID: 32196668 DOI: 10.1111/joa.13183] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2019] [Revised: 10/11/2019] [Accepted: 02/19/2020] [Indexed: 12/22/2022] Open
Abstract
Musculoskeletal conditions can change tissue elasticity. Knowledge of musculoskeletal elasticity could therefore aid clinical diagnosis and management. Sonoelastography is an ultrasound-based system that examines the material properties of tissues, and it may be useful in musculoskeletal practice. Therefore, it is important to establish its clinimetric properties. This study aimed to explore the intra-rater reliability and the smallest detectable changes of sonoelastography in examining musculoskeletal structures. A quantitative reliability design was used to examine 22 healthy participants using a compression sonoelastography system that produces color-coded images. The deltoid, biceps brachii, brachioradialis, rectus femoris, gastrocnemius medius muscles, and Achilles tendon were examined twice at 1-hr intervals to assess the intra-rater reliability. The sonoelastography images were analyzed using the strain index, strain ratio, and color pixels. The intra-rater reliability and the smallest detectable changes of each outcome variable were determined. The intra-class correlation coefficient was used to quantify the repeatability of the measurements, and the smallest detectable changes were calculated to determine clinically important differences above the error of measurement. The intra-rater reliability for the strain index, strain ratio, and color pixel analysis ranged from moderate to excellent (intra-class correlation coefficients: .734-.950, .776-.921, and .754-.990, respectively), with color pixel analysis demonstrating the highest reliability. The smallest detectable changes were determined for all structures, including the Achilles tendon (0.11 for the higher boundary of the strain index, 1.80 for the strain ratio, and 2.90% for red pixels, representing soft tissues). Color pixel analysis may be more reliable for sonoelastography interpretation compared with the strain index and strain ratio. The calculated smallest detectable changes could be used to identify clinically important differences.
Collapse
Affiliation(s)
- Najla Alsiri
- Al-Razi Orthopedic and Rehabilitation Hospital, Kuwait City, Kuwait
| | - Saud Al-Obaidi
- Faculty of Allied Health Sciences, Kuwait University, Kuwait City, Kuwait
| | - Akram Asbeutah
- Faculty of Allied Health Sciences, Kuwait University, Kuwait City, Kuwait
| | - Shea Palmer
- Faculty of Health and Applied Sciences, University of the West of England, Bristol, UK
| |
Collapse
|
32
|
Jeong MR, Lee IS, Shin YB, Song YS, Park S, Song JW, Moon JI. Clinical Efficacy of Real-Time Sonoelastography for the Follow-Up of Congenital Sternocleidomastoid Muscle Torticollis. JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY 2020; 81:176-189. [PMID: 36238111 PMCID: PMC9432086 DOI: 10.3348/jksr.2020.81.1.176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 07/26/2019] [Accepted: 07/31/2019] [Indexed: 11/15/2022]
Abstract
Purpose To evaluate the clinical efficacy of real-time sonoelastography (RTS) for the follow-up of congenital muscular torticollis, based on measurements of muscle elasticity. Materials and Methods Thirty-four infants (23 male, 11 female) with congenital sternocleidomastoid (SCM) muscle torticollis underwent ultrasonography and elastography between November 2012 and December 2014. We evaluated the thickness, morphology (mass-like, fusiform, or overall thickened shape), and echogenicity of the SCM muscle on grayscale images and color patterns (homogeneous blue, mixed green < 50% and ≥ 50%, and green to red) on elastography. Strain ratios were measured using Q-lab software. A clinician classified the degree of neck rotation and side flexion deficits using a 5-point grade system based on angles of neck rotation and side flexion. Correlations between the ultrasonography and clinical findings were evaluated by statistical analysis. Results Twenty-two infants had right and 12 had left SCM torticollis, respectively. Linear regression analysis showed that involved/contralateral SCM thickness differences, morphology, elasticity color scores, and strain ratios of the affected SCM muscles were significantly correlated with neck rotation and side flexion deficit scores (p < 0.05). The elasticity color score of the affected SCM muscle was the most significant factor. Conclusion RTS might provide a reliable means for evaluating and monitoring congenital muscular torticollis.
Collapse
Affiliation(s)
- Mi ri Jeong
- Department of Radiology, Pusan National University Hospital, Biomedical Research Institute, Busan, Korea
- Department of Radiology, Pusan National University School of Medicine, Busan, Korea
| | - In Sook Lee
- Department of Radiology, Pusan National University Hospital, Biomedical Research Institute, Busan, Korea
- Department of Radiology, Pusan National University School of Medicine, Busan, Korea
| | - Yong Beom Shin
- Department of Radiology, Pusan National University School of Medicine, Busan, Korea
- Department of Rehabilitation, Pusan National University Hospital, Biomedical Research Institute, Busan, Korea
| | - You Seon Song
- Department of Radiology, Pusan National University Hospital, Biomedical Research Institute, Busan, Korea
- Department of Radiology, Pusan National University School of Medicine, Busan, Korea
| | - Sekyoung Park
- Department of Radiology, Kosin University Gospel Hospital, Busan, Korea
| | - Jong Woon Song
- Department of Radiology, Inje University Haeundae Paik Hospital, Busan, Korea
| | - Jin Il Moon
- Department of Radiology, Gyeongsang National University Changwon Hospital, Changwon, Korea
| |
Collapse
|
33
|
Kim DY, Miyakawa S, Fukuda T, Takemura M. Sex Differences in Iliotibial Band Strain under Different Knee Alignments. PM R 2019; 12:479-485. [PMID: 31583829 DOI: 10.1002/pmrj.12255] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Accepted: 09/16/2019] [Indexed: 12/21/2022]
Abstract
BACKGROUND Increased strain of the iliotibial band (ITB) is a plausible contributing factor for the development of iliotibial band syndrome (ITBS). Although several studies have found relationships between the strain of the ITB and kinematic factors during running, the associations of the ITB strain with knee alignment and sex, which are considered intrinsic factors, are not well understood. OBJECTIVE To clarify the sex differences in the ITB strain between genu varum and normal knee alignments in different postures. DESIGN Observational cross-sectional study. SETTING Laboratory research within a university. PARTICIPANTS Forty-four healthy recreational athletes (21 men and 23 women) volunteered for this study and were divided into four groups by sex and knee alignment: men with genu varum alignment, men with normal knee alignment, women with genu varum alignment, and women with normal knee alignment. METHODS An ultrasound real-time elastography (RTE) unit was used for distal ITB strain measurements in weight bearing and for different non-weight-bearing: neutral, knee flexion, hip adduction, and hip adduction with knee flexion. Gender information and the intercondylar distance data were collected to divide the participants into two groups. MAIN OUTCOME MEASUREMENTS Main Outcome was the ITB strain (strain ratio) measured by the RTE. RESULTS There were no significant differences in neutral and hip adduction postures among the four groups. However, during weight-bearing, the women's genu varum group (6.91 ± 1.69; Mean ± SD) exhibited greater strain than both the men's normal group (3.50 ± 1.04, P = .005) and the women's normal group (4.42 ± 1.42, P = .048). In addition, there were significant positive correlations between the intercondylar distance and the ITB strain during weight-bearing (r = 0.315, P = .037). CONCLUSIONS The women's genu varum group exhibited a higher ITB strain during weight-bearing, which may be related to the high incidence of ITBS in women athletes. Furthermore, the changes in alignment and muscle activities during weight-bearing could influence the strain of the ITB. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Da Yoon Kim
- Doctoral Programs in Sports Medicine, Graduate School of Comprehensive Human Sciences, University of Tsukuba, Tsukuba, Japan
| | - Shumpei Miyakawa
- Faculty of Health and Sport Sciences, University of Tsukuba, Tsukuba, Japan
| | - Takashi Fukuda
- Faculty of Health and Sport Sciences, University of Tsukuba, Tsukuba, Japan
| | - Masahiro Takemura
- Faculty of Health and Sport Sciences, University of Tsukuba, Tsukuba, Japan
| |
Collapse
|
34
|
Sakai S, Maeda N, Sasadai J, Kotoshiba S, Anami K, Tashiro T, Fujishita H, Urabe Y. Effect of 4-week cyclic stretching program on muscle properties and physical performance in healthy adult men. J Sports Med Phys Fitness 2019; 60:37-44. [PMID: 31640312 DOI: 10.23736/s0022-4707.19.09870-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND The short-term effect of cyclic stretching (CS) has been found to decrease muscle hardness and improve physical performance. However, the long-term effect of CS program was unclear. This study investigated the long-term effect of CS program on muscle properties and physical performance. METHODS Eighteen healthy men participated in this study. The participants were assigned randomly to either the CS or control group (9 participants in each group) to conduct 2 min CS of the plantar flexor muscles 5 times a week for 4 weeks. Before and after intervention, the gastrocnemius medialis muscle hardness, muscle-tendon joint (MTJ) angle, and MTJ displacement (ΔMTJ) were measured as indices of muscle properties. In addition, the maximum range of motion of ankle dorsiflexion (ROM max), normalized maximum peak torque of plantar flexor (NPT), vertical jump height, and dynamic postural stability, dynamic postural stability index (DPSI) were measured as indices of physical performance. RESULTS The CS program was found to significantly decrease muscle hardness and increase vertical jump height and ROM max, but not to change the MTJ angle, ΔMTJ, NPT, and DPSI. CONCLUSIONS The results of our study suggested that long-term CS program was effective in decreasing muscle hardness and increasing vertical jump height.
Collapse
Affiliation(s)
- Shogo Sakai
- Department of Sports Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Noriaki Maeda
- Department of Sports Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Junpei Sasadai
- Department of Sports Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Somu Kotoshiba
- Department of Sports Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Keitaro Anami
- Department of Sports Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Tsubasa Tashiro
- Department of Sports Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | | | - Yukio Urabe
- Department of Sports Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan -
| |
Collapse
|
35
|
Al-Qahtani M, Al-Tayyar S, Mirza EH, Al-Musallam A, Al-Suwayyid A, Javed R. Body Mass Index and Segmental Mass Correlation With Elastographic Strain Ratios of the Quadriceps Tendon. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2019; 38:2005-2013. [PMID: 30570166 DOI: 10.1002/jum.14889] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Revised: 10/04/2018] [Accepted: 11/08/2018] [Indexed: 06/09/2023]
Abstract
OBJECTIVES The aim of this study was to establish a relationship between quadriceps tendon stiffness and its properties and variations in the body mass index (BMI) and segmental mass. METHODS This study was conducted in 3 groups according to their BMI (A, low [<18.5 kg/m2 ]; B, normal [18.5-25.0 kg/m2 ]; and C, high [>25.0 kg/m2 ]). All of the participants included had a sedentary lifestyle and did not do any weightlifting or any kind of sports activity in the previous 6 months. Ultrasound measurements were performed on the participants' lower right extremities, since it was the dominant side for all of the participants. RESULTS A total of 40 healthy untrained men participated in the study. The mean age of the participants ± SD was 22.1 ± 1.3 years; the age ranges for groups A (n = 6), B (n = 18), and C (n = 16) were 19-23, 19-25, and 20-25 years, respectively; 28 of the participants were nonsmokers, and 12 of were smokers. A strong statistical difference (all P < .05) was witnessed for most of the parameters (BMI, body fat mass, dominant leg body fat content, fat-free mass index, tendon thickness, and strain ratio) among the groups. CONCLUSIONS The length of the tendon did not show a significant increase with an increase in the BMI, body fat mass, dominant leg body fat content, and fat-free mass index. However, a greater intensification was observed for the thickness of the tendon with a significant increase in tendon stiffness (with the use of external reference material).
Collapse
Affiliation(s)
- Mahdi Al-Qahtani
- Biomedical Technology Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Saleh Al-Tayyar
- Biomedical Technology Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Eraj Humayun Mirza
- Biomedical Engineering Department, NED University of Engineering and Technology, Karachi, Pakistan
| | - Abdulrhman Al-Musallam
- Biomedical Technology Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Ahmed Al-Suwayyid
- Biomedical Technology Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Ravish Javed
- Biomedical Technology Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
36
|
Ok N, Agladioglu K, Gungor HR, Akkaya N, Akkaya S. Strain Ratio Measurements of Patellar and Achilles Tendons With Different Reference Regions in Healthy Volunteers. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:2027-2033. [PMID: 31104866 DOI: 10.1016/j.ultrasmedbio.2019.04.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2018] [Revised: 04/12/2019] [Accepted: 04/29/2019] [Indexed: 06/09/2023]
Abstract
Strain ratio measurements of tendons vary because of the reference tissue selection. The main purpose of this study is to highlight, in detail, the numeric variability attributable to the use of various reference materials on strain ratio measurements of patellar and Achilles tendons. Measurements were performed at the proximal, middle and distal thirds of the patellar and Achilles tendons on the dominant site of healthy volunteers. A total of 3 references were used: the Hoffa's fat pad for the patellar tendon, the Kager's fat pad for the Achilles tendon, subcutaneous tissue and Aquaflex gel pads (Parker Laboratories, Fairfield, NJ, USA) for both tendons. Although the same methods were used by the same physician for each tendon site on repeated measurements, strain ratio values had numeric variability with various reference materials in each measurement. Therefore, comparison of numeric strain ratio results of various studies with various reference materials could confuse the clinical interpretations of these numeric data, and, using a reference material with standard stiffness like Aquaflex ultrasound gel pads, should be considered by verifying these results with further studies.
Collapse
Affiliation(s)
- Nusret Ok
- Pamukkale University Medical Faculty, Department of Orthopedics and Traumatology, Pamukkale, Denizli, Turkey
| | - Kadir Agladioglu
- Medistate Kavacik Hospital, Department of Radiology, Kavacık, Beykoz, Istanbul, Turkey
| | - Harun R Gungor
- Pamukkale University Medical Faculty, Department of Orthopedics and Traumatology, Pamukkale, Denizli, Turkey.
| | - Nuray Akkaya
- Pamukkale University Medical Faculty, Department of Physical and Rehabilitation Medicine, Pamukkale, Denizli, Turkey
| | - Semih Akkaya
- Denipol Hospital, Department of Orthopedics and Traumatology, Merkezefendi, Denizli, Turkey
| |
Collapse
|
37
|
A novel application of strain sonoelastography can detect changes in Achilles tendon elasticity during isometric contractions of increasing intensity. J Foot Ankle Res 2019; 12:30. [PMID: 31139262 PMCID: PMC6528184 DOI: 10.1186/s13047-019-0342-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2018] [Accepted: 05/10/2019] [Indexed: 12/21/2022] Open
Abstract
Background Mechanical and morphological properties of the Achilles tendon are altered in disease and in response to changes in mechanical loading. In the last few years different ultrasound based technologies have been used to detect tendon mechanical properties changes mainly in resting condition. Therefore the aim of this study was to evaluate if strain sonoelastography can identify changes in Achilles tendon elasticity during isometric contractions of increasing intensity. Methods This cross-sectional study enrolled 37 healthy volunteers (19 women) with mean (±SD) age of 27.1 (±7.0) years between January and June 2017. Strain sonoelastography images of the Achilles tendon were acquired during an isometric ramp force (0 kg, 0.5 kg, 1 kg, 2 kg, 5 kg and, 10 kg). An external reference material was used to provide a comparison between the examined tissue and a material of constant elasticity. Friedman test with post hoc pairwise comparison were used to determine the correlation between the difference contraction levels. Results The median and interquartile range (IQR) values for the strain ratio were 1.61 (1.5–2.9) in a relaxed state and 1.30 (1.07–2.02), 1.00 (0.76–1.66), 0.81 (0.70–1.19), 0.47 (0.39–0.73) and 0.33 (0.28–0.40) for 0.5 kg, 1 kg, 2 kg, 5 kg and 10 kg, respectively revealing increased tendon hardness with increasing contraction intensities. Friedman test revealed significant differences (p < 0.05) in the strain ratio between all contractions except between 0.5 kg – 1 kg (p = 0.41); 1 kg – 2 kg (p = 0.12) and 5 kg – 10 kg (p = 0.12). Conclusion Strain sonoelastography can detect changes in Achilles tendon elasticity between different contraction intensities. The results provide an original force-elasticity curve for the Achilles tendon in a healthy, asymptomatic population. Trial registration The study was approved by the Ethics Committee of Canton Ticino.
Collapse
|
38
|
Frich LH, Lambertsen KL, Hjarbaek J, Dahl JS, Holsgaard-Larsen A. Musculoskeletal application and validation of speckle-tracking ultrasonography. BMC Musculoskelet Disord 2019; 20:192. [PMID: 31054565 PMCID: PMC6499961 DOI: 10.1186/s12891-019-2562-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2018] [Accepted: 04/09/2019] [Indexed: 01/26/2023] Open
Abstract
Background Diseased, injured, or dysfunctional skeletal muscles may demonstrate abnormal function and contractility. Currently, only few in vivo imaging techniques are able to characterize the contractile properties of muscle tissue. This study aimed to test the hypothesis that muscle strain can be tracked in two upper extremity skeletal muscles by speckle-tracking ultrasonography (STU) and correlates with isometric muscle contractions. Methods A convenience sample of 10 healthy, adult volunteers with normal shoulder function were tested. The 5 women and 5 men had a mean age of 45 years (range: 39–59 years) and BMI < 30. STU was applied to the supraspinatus (SS) and biceps brachii (BB) muscles using a M11 L-MHz linear transducer (frequency 8–15 MHz) hooked to a Vivid E 9TM ultrasound machine. Strain validation was performed by correlating peak strain against standardized sub-maximal, isometric load conditions of the two muscles (20–80% of maximal voluntary contraction) using a custom-built muscle dynamometer based on strain-gauge technique. Data were analyzed offline using the EchoPac speckle-tracking software and were blinded to the examiner. Results Intramuscular strain measured by STU in the SS and BB muscles showed moderate to strong correlations with external muscle load (SS: r = − 0.76, p < 0.0001 and BB: r = − 0.60, p < 0.0001). We found strain to vary from approximately 10–20% during increasing submaximal, isometric conditions. Conclusions We demonstrate that STU can be applied on healthy skeletal musculature (SS and BB muscles). The observed correlations between strain and isometric contractions suggest a valid technique. However, the concept of measuring muscle strain non-invasively needs further investigation for validity, accuracy, responsiveness, and reliability before its therapeutic and research potential can be realized.
Collapse
Affiliation(s)
- Lars Henrik Frich
- Department of Orthopaedics and Traumatology, Odense University Hospital, J.B. Winsloewsvej 4, 5000, Odense, Denmark. .,Orthopaedic research unit, University of Southern Denmark, J.B. Winsloewsvej 4, 5000, Odense, Denmark. .,OPEN, Odense Patient data Explorative Network, Odense University Hospital/Department of Clinical Research, University of Southern Denmark, J.B. Winsloewsvej 4, 5000, Odense, Denmark.
| | - Kate Lykke Lambertsen
- Department of Neurobiology Research, Institute of Molecular Medicine, University of Southern Denmark, Odense, Denmark.,Department of Neurology, Odense University Hospital, Odense, Denmark.,BRIDGE - Brain Research - Inter-Disciplinary Guided Excellence, Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - John Hjarbaek
- Department of Radiology, Odense University Hospital, Odense, Denmark
| | | | - Anders Holsgaard-Larsen
- Department of Orthopaedics and Traumatology, Odense University Hospital, J.B. Winsloewsvej 4, 5000, Odense, Denmark.,Orthopaedic research unit, University of Southern Denmark, J.B. Winsloewsvej 4, 5000, Odense, Denmark
| |
Collapse
|
39
|
Imai K, Kotani T, Ushida T, Moriyama Y, Nakano T, Kikkawa F. Feasibility of using a handheld tissue hardness meter to quantify uterine contractions and its clinical application for obstetric bleeding management. J OBSTET GYNAECOL 2019; 39:757-762. [PMID: 31020886 DOI: 10.1080/01443615.2019.1581748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Postpartum haemorrhage (PPH) is a potentially life-threatening condition. Women undergoing caesarean section (CS) are at particular risk, and improvements in the management of PPH during CS are required. We investigated the use of a tissue hardness metre to quantify uterine contractions during CS with a view to its application for obstetric bleeding management. Fifty pregnant women at term who underwent elective CS were recruited. Using a tissue hardness metre, we measured uterine hardness twice during CS: after placental removal and before peritoneum closure. Each measurement was conducted at two standardised points: fundus and corpus uteri. Concurrently, obstetricians subjectively graded uterine contractions as weak, medium, or strong. The hardness metre accurately quantified the degree of uterine contraction assessed by the obstetricians, and could be an effective clinical tool for early recognition of intra-operative massive bleeding. IMPACT STATEMENT What is already known on this subject? Maintaining adequate uterine contraction leads to prevention of excessive blood loss, which decreases the incidence and severity of PPH. However, the assessment of uterine contraction is currently judged by obstetricians, who manually and subjectively evaluate uterine contraction according to uterine hardness. Therefore, uterine atony remains a clinical diagnosis without a universal definition. What do the results of this study add? The present study investigated the use of a tissue hardness metre to quantify uterine contractions during CS with a view to its application for obstetric bleeding management. The hardness metre was able to quantify the degree of uterine contraction perceived by obstetricians. Quantifying uterine hardness during CS correlates with the amount of intra-operative bleeding and is useful for early recognition of massive haemorrhage. What are the implications of these findings for clinical practice and/or further research? To improve the management of atonic PPH and avoid serious complications, the tissue hardness metre should be considered as a potential clinical tool during CS.
Collapse
Affiliation(s)
- Kenji Imai
- a Department of Obstetrics and Gynecology , Nagoya University Graduate School of Medicine , Nagoya , Japan
| | - Tomomi Kotani
- a Department of Obstetrics and Gynecology , Nagoya University Graduate School of Medicine , Nagoya , Japan
| | - Takafumi Ushida
- a Department of Obstetrics and Gynecology , Nagoya University Graduate School of Medicine , Nagoya , Japan
| | - Yoshinori Moriyama
- a Department of Obstetrics and Gynecology , Nagoya University Graduate School of Medicine , Nagoya , Japan
| | - Tomoko Nakano
- a Department of Obstetrics and Gynecology , Nagoya University Graduate School of Medicine , Nagoya , Japan
| | - Fumitaka Kikkawa
- a Department of Obstetrics and Gynecology , Nagoya University Graduate School of Medicine , Nagoya , Japan
| |
Collapse
|
40
|
Song Y, Zhang TJ, Li Y, Gao Y. Application of real-time shear wave elastography in the assessment of torsional cervical dystonia. Quant Imaging Med Surg 2019; 9:662-670. [PMID: 31143657 DOI: 10.21037/qims.2019.04.08] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Background This study aimed to investigate the value of real-time shear wave elastography (SWE) in the assessment of torsional cervical dystonia (TCD). Methods Ninety healthy volunteers and 30 TCD patients were recruited, and elastography was performed at musculi sternocleidomastoideus (MSD) and musculi splenius capitis (MSC). Mean shear elastic modulus of right MSD and MSC in healthy controls and bilateral MSD and MSC in TCD patients was determined. The thickness of MSD and MSC of affected muscles was measured in TCD patients. Results In TCD patients, the mean shear elastic modulus of affected MSD and MSC was significantly higher than that of corresponding normal muscles (P<0.01) and that of controls (P<0.01). The diagnostic threshold was 24.9 kPa for MSD and 25.07 kPa for MSC (for MSD and MSC, the area under ROC was 0.979 and 0.979, with a sensitivity of 90% and 91.3%, and a specificity of 95.6% and 96.7%, respectively). The elastic modulus of neither affected nor normal MSD and MSC was significantly related to age and body mass index (P>0.05). The shear elastic modulus of affected MSD and MSC was positively related to the peak electromyography (r=0.83-0.73, P<0.01). The thickness of affected MSD and MSC was significantly thicker than that of corresponding normal muscles in TCD patients (P<0.01). Conclusions Real-time SWE can identify the difference in shear elastic modulus of MSD and MSC between the affected and normal side in TCD patients, indicating important diagnostic value in the assessment of muscular status for these patients.
Collapse
Affiliation(s)
- Ye Song
- Department of Ultrasonography, Zhoupu Hospital, Shanghai University of Medicine & Health Sciences, College of Medical Imaging, Shanghai 201318, China
| | - Tian-Jie Zhang
- Shanghai Huapukang Pediatric Clinic, Shanghai 310105, China
| | - Yuan Li
- Department of Ultrasonography, Zhoupu Hospital, Shanghai University of Medicine & Health Sciences, College of Medical Imaging, Shanghai 201318, China
| | - Yuan Gao
- Department of Surgery, Tongji Hospital of Tongji University, Shanghai 200065, China
| |
Collapse
|
41
|
Na XMD, Bei XMD, Wei SMD, Ningning TMD, ZhiXia WMD, Binxuan HMD, Hongwei TMD. Dual Modal Ultrasound Elastography of the Sternocleidomastoid Muscle in Healthy Infants: A Prospective Study. ADVANCED ULTRASOUND IN DIAGNOSIS AND THERAPY 2019. [DOI: 10.37015/audt.2019.191219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
|
42
|
Assessing the elastic properties of skeletal muscle and tendon using shearwave ultrasound elastography and MyotonPRO. Sci Rep 2018; 8:17064. [PMID: 30459432 PMCID: PMC6244233 DOI: 10.1038/s41598-018-34719-7] [Citation(s) in RCA: 124] [Impact Index Per Article: 20.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Accepted: 10/24/2018] [Indexed: 12/19/2022] Open
Abstract
The purposes of this study were to compare Young’s modulus values determined by shear wave ultrasound elastography (SWUE) with stiffness index obtained using a hand-held MyotonPRO device on the resting stiffness of gastrocnemius muscle belly and Achilles tendon; and to examine the test-retest reliability of those stiffness measurement using hand-held MyotonPRO. Twenty healthy volunteers participated in the study. The measurement values of muscle and tendon was determined in dominant legs. Each marker point was assessed using MyotonPRO and SWUE, respectively. Intra-operator reliability of MyotonPRO was established in 10 of the subjects. The correlation coefficients between the values of muscle and tendon stiffness indices determined by MyotonPRO and SWUE were calculated. Significant correlations were found for muscle and tendon stiffness and Young’s modulus ranged from 0.463 to 0.544 (all P < 0.05). The intra-operator reliability ranged from good to excellent (ICC(3,1) = 0.787~0.928). These results suggest that the resting stiffness of gastrocnemius muscle belly and Achilles tendon measured by MyotonPRO is related to the Young’s modulus of those quantified by SWUE. The MyotonPRO shows good intra-operator repeatability. Therefore, the present study shows that MyotonPRO can be used to assess mechanical properties of gastrocnemius muscle belly and Achilles tendon with a resting condition.
Collapse
|
43
|
Evaluation of the activities of the medial and lateral heads of quadratus plantae in flexion movements of the lateral four toes using ultrasound real-time tissue elastography. Foot (Edinb) 2018; 36:25-29. [PMID: 30326349 DOI: 10.1016/j.foot.2018.02.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Revised: 01/18/2018] [Accepted: 02/28/2018] [Indexed: 02/04/2023]
Abstract
Quadratus plantae (QP), one of the plantar intrinsic foot muscles, assist plantarflexion of the lesser toes. QP has medial and lateral muscle heads with different anatomical structures. The two heads of this muscle may have different roles in foot function. Ultrasound real-time tissue elastography (RTE) measurements have allowed quantitative assessment of deep-layer muscle elasticity. The purpose of this study was to determine the activity of the QP in flexion movements of the lateral four toes using RTE. Thirteen healthy subjects performed maximal voluntary contractions using a hand-held dynamometer with external belt fixation for each toe flexion movement. The elasticity of the muscles were measured using RTE during rest and flexion of each toe. The strain ratio of the muscle to that in an acoustic coupler was calculated as an index of muscle elasticity. Higher strain ratio values imply lower elasticity. The strain ratio of the medial head of QP for second toe flexion (0.10±0.11) was significantly stiffer than at rest (0.34±0.33). The strain ratios of the lateral head of QP for flexion of the second (0.32±0.19), third (0.41±0.37), fourth (0.33±0.26), and fifth (0.45±0.39) toes were significantly stiffer than at rest (1.02±0.68). These results suggest that the medial head of QP has a role in assisting second-toe flexion, and the lateral head has a role in assisting flexion of all four lateral toes.
Collapse
|
44
|
Alsiri N, Al-Obaidi S, Asbeutah A, Almandeel M, Palmer S. The impact of hypermobility spectrum disorders on musculoskeletal tissue stiffness: an exploration using strain elastography. Clin Rheumatol 2018; 38:85-95. [DOI: 10.1007/s10067-018-4193-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 06/13/2018] [Accepted: 06/26/2018] [Indexed: 10/28/2022]
|
45
|
Sconfienza LM, Albano D, Allen G, Bazzocchi A, Bignotti B, Chianca V, Facal de Castro F, Drakonaki EE, Gallardo E, Gielen J, Klauser AS, Martinoli C, Mauri G, McNally E, Messina C, Mirón Mombiela R, Orlandi D, Plagou A, Posadzy M, de la Puente R, Reijnierse M, Rossi F, Rutkauskas S, Snoj Z, Vucetic J, Wilson D, Tagliafico AS. Clinical indications for musculoskeletal ultrasound updated in 2017 by European Society of Musculoskeletal Radiology (ESSR) consensus. Eur Radiol 2018; 28:5338-5351. [DOI: 10.1007/s00330-018-5474-3] [Citation(s) in RCA: 143] [Impact Index Per Article: 23.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Revised: 04/02/2018] [Accepted: 04/11/2018] [Indexed: 12/11/2022]
|
46
|
Yokota Y, Sonoda T, Tashiro Y, Suzuki Y, Kajiwara Y, Zeidan H, Nakayama Y, Kawagoe M, Shimoura K, Tatsumi M, Nakai K, Nishida Y, Bito T, Yoshimi S, Aoyama T. Effect of Capacitive and Resistive electric transfer on changes in muscle flexibility and lumbopelvic alignment after fatiguing exercise. J Phys Ther Sci 2018; 30:719-725. [PMID: 29765189 PMCID: PMC5940481 DOI: 10.1589/jpts.30.719] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2017] [Accepted: 02/27/2018] [Indexed: 11/24/2022] Open
Abstract
[Purpose] This study aimed to clarify the effects of Capacitive and Resistive electric transfer (CRet) on changes in muscle flexibility and lumbopelvic alignment after fatiguing exercise. [Subjects and Methods] Twenty-two healthy males were assigned into either the CRet (n=11) or control (n=11) group. Fatiguing exercise and CRet intervention were applied at the quadriceps muscle of the participants' dominant legs. The Ely test, pelvic tilt, lumbar lordosis, and superficial temperature were measured before and after exercise and for 30 minutes after intervention. Statistical analysis was performed using one-way analysis of variance, with Tukey's post-hoc multiple comparison test to clarify within-group changes and Student's t-test to clarify between-group differences. [Results] The Ely test and pelvic tilt were significantly different in both groups after exercise, but there was no difference in the CRet group after intervention. Superficial temperature significantly increased in the CRet group for 30 minutes after intervention, in contrast to after the exercise and intervention in the control group. There was no significant between-group difference at any timepoint, except in superficial temperature. [Conclusion] CRet could effectively improve muscle flexibility and lumbopelvic alignment after fatiguing exercise.
Collapse
Affiliation(s)
- Yuki Yokota
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| | - Takuya Sonoda
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| | - Yuto Tashiro
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| | - Yusuke Suzuki
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| | - Yu Kajiwara
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
- Department of Physical Therapy, Faculty of Health Science,
Kio University, Japan
| | - Hala Zeidan
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| | - Yasuaki Nakayama
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| | - Mirei Kawagoe
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| | - Kanako Shimoura
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| | - Masataka Tatsumi
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| | - Kengo Nakai
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| | - Yuichi Nishida
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| | - Tsubasa Bito
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| | - Soyoka Yoshimi
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| | - Tomoki Aoyama
- Department of Physical Therapy, Human Health Sciences,
Graduate School of Medicine, Kyoto University: 53 Kawaharamachi Shogoin, Sakyo-ku, Kyoto
606-8507, Japan
| |
Collapse
|
47
|
Arima Y. Studying Hardness Meter Spring Strength to Understand Hardness Distribution on Body Surfaces. J Acupunct Meridian Stud 2017; 10:340-345. [PMID: 29078969 DOI: 10.1016/j.jams.2017.08.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Revised: 08/04/2017] [Accepted: 08/08/2017] [Indexed: 10/19/2022] Open
Abstract
INTRODUCTION For developing a hardness multipoint measurement system for understanding hardness distribution on biological body surfaces, we investigated the spring strength of the contact portion main axis of a biological tissue hardness meter (product name: PEK). METHODS We measured the hardness of three-layered sheets of six types of gel sheets (90 mm × 60 mm × 6 mm) constituting the acupuncture practice pads, with PEK measurements of 1.96 N, 2.94 N, 3.92 N, 4.90 N, 5.88 N, 6.86 N, 7.84 N, 8.82 N, and 9.81 N of the main axis spring strength. We obtained measurements 10 times for the gel sheets and simultaneously measured the load using a digital scale. We measured the hardness distribution of induration embedded and breast cancer palpation models, with a main axis with 1.96 N, 4.90 N, and 9.81 N spring strengths, to create a two-dimensional Contour Fill Chart. RESULTS Using 4.90 N spring strength, we could obtain measurement loads of ≤3.0 N, and the mean hardness was 5.14 mm. This was close to the median of the total measurement range 0.0-10.0 mm, making the measurement range the largest for this spring strength. We could image the induration of the induration-embedded model regardless of the spring strength. CONCLUSION Overall, 4.90 N spring strength was best suited for imaging cancer in the breast cancer palpation model.
Collapse
Affiliation(s)
- Yoshitaka Arima
- Department of Acupuncture and Moxibustion Therapy, Faculty of Health Promotional Sciences, Tokoha University, Hamamatsu-shi, Shizuoka, Japan.
| |
Collapse
|
48
|
Gao J, Li PC, Chen J, He W, Du LJ, Min R, O'Dell M. Ultrasound Strain Imaging in Assessment of Biceps Muscle Stiffness and Dynamic Motion in Healthy Adults. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1729-1736. [PMID: 28549736 DOI: 10.1016/j.ultrasmedbio.2017.04.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 04/11/2017] [Accepted: 04/12/2017] [Indexed: 06/07/2023]
Abstract
We prospectively evaluated the feasibility of using ultrasound strain imaging (USI) to assess biceps brachii muscle (BBM) stiffness and dynamic motion in 10 healthy adults. The BBM axial deformation was produced by external compression with a sandbag (1.0 kg) tied onto the transducer. The BBM lateral movement was produced by manual passive elbow flexion and extension. By use of 2-D speckle tracking, captured 5-s real-time ultrasound data of BBM were processed to estimate axial strain, representing muscle stiffness, and lateral strain and tissue velocity, representing muscle dynamic motion. Axial (lateral) strain ratio was defined as BBM strain divided by subcutaneous soft tissue strain. There was no significant difference in lateral strain or tissue velocity between the left and right BBM (lateral strain ratio: 4.69 ± 0.07 vs. 4.51 ± 0.08 for extension, 4.82 ± 0.09 vs. 4.69 ± 0.11 for flexion; tissue velocity: 1.58 ± 0.32 cm/s vs. 1.78 ± 0.85 cm/s for extension, -2.03 ± 0.63 vs. -2.03 ± 0.59 for flexion; all p values > 0.05) or between men and women (lateral strain ratio: 4.52 ± 0.06 vs. 4.67 ± 0.1 for extension, 4.71 ± 0.11 vs. 4.83 ± 0.09 for flexion; tissue velocity, cm/s: 1.76 ± 0.76 vs. 1.66 ± 0.65 for extension, -2.21 ± 0.65 vs. -1.88 ± 0.52 for flexion, all p values > 0.05). The difference in axial stain between men and women was significant (axial strain ratio: 3.09 ± 0.43 vs. 3.52 ± 0.26, p = 0.02). Inter- and intra-observer reliability in performing USI of the BBM was good (all intra-class correlation coefficients [ICCs] >0.75). Our results suggest that USI seems to be feasible for and reproducible in estimating BBM mechanical properties and motion dynamics in healthy adults.
Collapse
Affiliation(s)
- Jing Gao
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA.
| | - Pai-Chi Li
- Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan
| | - Johnson Chen
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | - Wen He
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Li-Juan Du
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Robert Min
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | - Michael O'Dell
- Department of Rehabilitation Medicine, Weill Cornell Medicine, New York, New York, USA
| |
Collapse
|
49
|
Inami T, Tsujimura T, Shimizu T, Watanabe T, Lau WY, Nosaka K. Relationship between isometric contraction intensity and muscle hardness assessed by ultrasound strain elastography. Eur J Appl Physiol 2017; 117:843-852. [DOI: 10.1007/s00421-016-3528-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Accepted: 12/08/2016] [Indexed: 01/16/2023]
|
50
|
Delayed-Onset Muscle Soreness: Temporal Assessment With Quantitative MRI and Shear-Wave Ultrasound Elastography. AJR Am J Roentgenol 2017; 208:402-412. [DOI: 10.2214/ajr.16.16617] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|