1
|
Ibrahem S, Morad L, Husein HA. Clinical Performance of Computer-Aided Design (CAD)/Computer-Aided Manufacturing (CAM) Resin Nanoceramic Endocrowns in Restoring Molars: An In Vivo Study. Cureus 2024; 16:e64252. [PMID: 39131021 PMCID: PMC11315435 DOI: 10.7759/cureus.64252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/10/2024] [Indexed: 08/13/2024] Open
Abstract
Background It is difficult to determine the optimal method for restoring endodontically treated teeth, as several factors affect this decision. Functional requirements and the amount of remaining coronal tissue are considered the most important factors in choosing the best restoration for those teeth. Endocrown was introduced as a conservative alternative for endodontically treated and coronally damaged teeth. Aim The aim of this study is to assess the clinical performance of the nanoceramic system for molar endocrowns by evaluating color change, gingival condition, prosthesis integrity, and the presence of secondary caries. Materials and methods The sample consisted of 20 endocrowns. The teeth were prepared with at least 2 mm of wall thickness and a cavity depth of 4 mm from the occlusal surface. The final impression was taken, and the prostheses were adhered using dual-cure resin cement. It was clinically evaluated according to clinical success criteria (United States Public Health Service) in terms of color stability, gingival indexes, integrity of the restoration, and the presence of secondary caries after a week, three months, six months, and a year. The statistical study was conducted using IBM SPSS Statistics for Windows, Version 23.0 (Released 2015; IBM Corp., Armonk, NY, USA), and the results were considered statistically significant at the 95% level of significance. The Friedman test was used to study the significance of the differences in the average values of color change, plaque index, and the integrity of the prostheses during follow-up periods. Results The study showed a gradual increase in the degree of color change with follow-up periods. Furthermore, there was no significant difference in the incidence of gingival changes, the integrity of the prosthetic margins, or the occurrence of secondary caries during the follow-up periods. Conclusions Within the limitations of this study, an endocrown made of CeraSmart nanoceramic is an acceptable option for crowning decayed and endodontic-treated molars with acceptable clinical performance.
Collapse
Affiliation(s)
- Sewar Ibrahem
- Fixed Prosthodontics, Faculty of Dental Medicine, Damascus University, Damascus, SYR
| | - Luai Morad
- Fixed Prosthodontics, Faculty of Dental Medicine, Damascus University, Damascus, SYR
| | - Hassan A Husein
- Fixed Prosthodontics, Faculty of Dental Medicine, Damascus University, Damascus, SYR
| |
Collapse
|
2
|
Yamaguchi S, Li H, Sakai T, Lee C, Kitagawa H, Imazato S. CAD-CAM resin composites: Effective components for further development. Dent Mater 2024; 40:527-530. [PMID: 38228428 DOI: 10.1016/j.dental.2024.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 01/06/2024] [Accepted: 01/09/2024] [Indexed: 01/18/2024]
Abstract
OBJECTIVE This paper summarizes the effective components of computer-aided design and computer-aided manufacturing (CAD-CAM) resin composites that contribute to achieving greater mechanical properties and further development. METHODS In silico multi-scale analysis, in silico nonlinear dynamic finite element analysis (FEA), and artificial intelligence (AI) were used to explore the effective components of CAD-CAM resin composites. The effects of the filler diameter and silane coupling ratio on the mechanical properties of CAD-CAM resin composites have been clarified through multi-scale analysis. The effects of the filler contents, and filler and monomer compositions have been investigated by AI algorithms. The fracture behavior of CAD-CAM composite crown was analyzed using in silico non-linear dynamic FEA. The longevity of CAD-CAM composite crown was assessed through step-stress accelerating life testing (SSALT). RESULTS As the filler diameter decreases, there is an increase in elastic moduli and compressive strengths at the macroscale. At the nanoscale, a decrease in the filler diameter results in a decrease in the maximum value of the maximum principal strain. When the silane coupling ratio decreases, there is a decrease in the elastic modulus and compressive strength. According to the exhaustive search and feature importance analysis based on the AI algorithm, the combination of certain components was narrowed down to achieve a flexural strength of 269.5 MPa. The in silico non-linear FEA successfully detected the sign of the initial crack of the CAD-CAM composite molar crown. The SSALT revealed that CAD-CAM resin composite molar crowns containing nanofillers with a high fraction of resin matrix demonstrated great longevity. SIGNIFICANCE This paper summarized the effective components of CAD-CAM resin composites for their further development. The integration of in vitro and in silico approaches will expedite the advancement of CAD-CAM resin composites, offering benefits such as time efficiency and reduction of material waste for researchers and manufacturers.
Collapse
Affiliation(s)
- Satoshi Yamaguchi
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan.
| | - Hefei Li
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Takahiko Sakai
- Department of Fixed Prosthodontics and Orofacial Function, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Chunwoo Lee
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Haruaki Kitagawa
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Satoshi Imazato
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan
| |
Collapse
|
3
|
Akarsu S, Atasoy S, Arıkan M, Koca B, Yiğin SN. Effects of three disinfection solutions on residual monomers released from resin nanoceramic CAD/CAM blocks. Heliyon 2024; 10:e24369. [PMID: 38317897 PMCID: PMC10838691 DOI: 10.1016/j.heliyon.2024.e24369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 01/05/2024] [Accepted: 01/08/2024] [Indexed: 02/07/2024] Open
Abstract
The aim of this study was to evaluate the effects of three disinfection solutions on the amount of monomers released from resin nanoceramic CAD/CAM blocks using high performance liquid chromatography (HPLC). Forty resin nanoceramic CAD/CAM (Cerasmart, GC, Japan) samples (12x14 × 2 mm) were divided into four groups; each group was disinfected using one of four solutions (Group 1: no disinfectant; Group 2: 70 % ethanol; Group 3: 2 % glutaraldehyde; and Group 4: 1 % sodium hypochlorite) for 5 min. Analysis of residual monomers (UDMA and Bis-EMA) amounts was performed using an HPLC instrument (Dionex Ultimate 3000, Thermo Fisher Scientific). After 30 days, the amounts of monomers found were as follows: 14.54 ppm for Group 1; 9.28 ppm for Group 2; 10.60 ppm for Group 3; and 2.76 ppm for Group 4 (the smallest monomer amount) (p < 0.001). Disinfection of indirect restorations prior to cementation can reduce the amount of residual monomers remaining from resin nanoceramic CAD/CAM blocks.
Collapse
Affiliation(s)
- Serdar Akarsu
- Ordu University, Faculty of Dentistry, Department of Restorative Dentistry, Turkey
| | - Samet Atasoy
- Ordu University, Faculty of Dentistry, Department of Restorative Dentistry, Turkey
| | - Merve Arıkan
- Ordu University, Faculty of Dentistry, Department of Restorative Dentistry, Turkey
| | - Bengisu Koca
- Ordu University, Faculty of Dentistry, Department of Restorative Dentistry, Turkey
| | - Sena Nur Yiğin
- Ordu University, Faculty of Dentistry, Department of Restorative Dentistry, Turkey
| |
Collapse
|
4
|
Yu Y, Guo X, Chen J, Zhao Y, Song J, Alshawwa H, Zou X, Zhao H, Zhang Z. Biodegradation of Urethane Dimethacrylate-based materials (CAD/CAM resin-ceramic composites) and its effect on the adhesion and proliferation of Streptococcus mutans. J Mech Behav Biomed Mater 2024; 150:106280. [PMID: 38043260 DOI: 10.1016/j.jmbbm.2023.106280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 11/24/2023] [Accepted: 11/26/2023] [Indexed: 12/05/2023]
Abstract
OBJECTIVE To investigate whether urethane dimethacrylate (UDMA) -based dental restorative materials biodegrade in the presence of Streptococcus mutans (S. mutans) and whether the monomers affect the adhesion and proliferation of S. mutans in turn. METHODS Cholesterol esterase and pseudocholinesterase-like activities in S. mutans were detected using p-nitrophenyl substrate. Two UDMA-based CAD/CAM resin-ceramic composites, Lava Ultimate (LU) and Vita Enamic (VE), and a light-cured UDMA resin block were co-cultured with S. mutans for 14 days. Their surfaces were characterized by scanning electron microscopy and laser microscopy, and the byproducts of biodegradation were examined by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS). Then, the antimicrobial components (silver nanoparticles with quaternary ammonium salts) were added to the UDMA resin block to detect whether the biodegradation was restrained. Finally, the effect of UDMA on biofilm formation and virulence expression of S. mutans was assessed. RESULTS Following a 14-day immersion, the LU and UDMA resin blocks' surface roughness increased. The LU and VE groups had no UDMA or its byproducts discovered, according to the UPLC-MS/MS data, whereas the light-cured UDMA block group had UDMA, urethane methacrylate (UMA), and urethane detected. The addition of antimicrobial agents showed a significant reduction in the release of UDMA. Biofilm staining experiments showed that UDMA promoted the growth of S. mutans biofilm and quantitative real-time polymerase chain reaction results indicated that 50 μg/mL UDMA significantly increase the expression of gtfB, comC, comD, comE, and gbpB genes within the biofilm. CONCLUSIONS UDMA in the light-cured resin can be biodegraded to produce UMA and urethane under the influence of S. mutans. The formation of early biofilm can be promoted and the expression of cariogenic genes can be up-regulated by UDMA. CLINICAL SIGNIFICANCE This study focuses for the first time on whether UDMA-based materials can undergo biodegradation and verifies from a genetic perspective that UDMA can promote the formation of S. mutans biofilms, providing a reference for the rational use of UDMA-based materials in clinical practice.
Collapse
Affiliation(s)
- Yiyan Yu
- Hospital of Stomatology, Jilin University, Changchun, China; Jilin Provincial Key Laboratory of Oral Biomedical Engineering, China
| | - Xinwei Guo
- School of Stomatology, Peking University, Beijing, China
| | - Jiawen Chen
- Hospital of Stomatology, Jilin University, Changchun, China; Jilin Provincial Key Laboratory of Oral Biomedical Engineering, China
| | - Yuanhang Zhao
- Hospital of Stomatology, Jilin University, Changchun, China; Jilin Provincial Key Laboratory of Oral Biomedical Engineering, China
| | - Jiazhuo Song
- Hospital of Stomatology, Jilin University, Changchun, China; Jilin Provincial Key Laboratory of Oral Biomedical Engineering, China
| | - Hamed Alshawwa
- Hospital of Stomatology, Jilin University, Changchun, China; Jilin Provincial Key Laboratory of Oral Biomedical Engineering, China
| | - Xinying Zou
- Hospital of Stomatology, Jilin University, Changchun, China; Jilin Provincial Key Laboratory of Oral Biomedical Engineering, China
| | - Hongyan Zhao
- Hospital of Stomatology, Jilin University, Changchun, China.
| | - Zhimin Zhang
- Hospital of Stomatology, Jilin University, Changchun, China.
| |
Collapse
|
5
|
Bayraktar ET, Türkmen C, Atali PY, Tarçin B, Korkut B, Yaşa B. In-vitro evaluation of wear characteristics, microhardness and color stability of dental restorative CAD/CAM materials. Dent Mater J 2024; 43:74-83. [PMID: 38072413 DOI: 10.4012/dmj.2023-071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
The aim of this study was to demonstrate the vertical and volumetric wear characteristics of CAD/CAM materials. The microhardness and color stability were evaluated. A polymer infiltrated ceramic network CAD/CAM block, resin nanoceramic CAD/CAM blocks, a resin composite, and enamel tissue were investigated. Samples were loaded in a chewing simulator. Other samples were aged and immersed in coffee. Color change was evaluated using the digital image analysis and a spectrophotometer. The data were analyzed using Kolmogorov-Smirnov, Kruskal Wallis, Mann Whitney U, Friedman, Spearman's rho tests (p<0.05). The lowest level of wear was obtained in enamel tissue group 0.20 (Q1:0.14; Q3:0.27μm). Resin composite group 2.48 (Q1:2.12; Q3:2.92) showed lower level of discoloration. No agreement was obtained between the digital image analysis and spectrophotometer data (Spearman's rho -0.314, p=0.014). Similar wear rate to the natural enamel tissue was obtained for Vita Enamic. Digital image analysis was considered a promising technique for monitoring the color change.
Collapse
Affiliation(s)
| | - Cafer Türkmen
- Department of Restorative Dentistry, Faculty of Dentistry, Marmara University
| | - Pınar Yilmaz Atali
- Department of Restorative Dentistry, Faculty of Dentistry, Marmara University
| | - Bilge Tarçin
- Department of Restorative Dentistry, Faculty of Dentistry, Marmara University
| | - Bora Korkut
- Department of Restorative Dentistry, Faculty of Dentistry, Marmara University
| | - Bilal Yaşa
- Department of Restorative Dentistry, Faculty of Dentistry, İstanbul Kent University
| |
Collapse
|
6
|
Eldafrawy M, Karevan Y, Nguyen JF, Mainjot A. Interblock and intrablock homogeneity of CAD-CAM composites mechanical properties. Dent Mater J 2023; 42:780-790. [PMID: 37853645 DOI: 10.4012/dmj.2023-090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2023]
Abstract
The purpose of this study was to characterize the homogeneity of the mechanical properties of commercial CAD-CAM composites between different blocks of the same material (interblock homogeneity) and within each block between the internal and external parts (intrablock homogeneity). Tetric CAD (TET); Katana Avencia (KAT); Cerasmart 270 (CER); Grandio (GRN) and Vita Enamic (ENA) were tested for flexural strength (σf), flexural modulus (Ef), flexural load energy (Ur) and hardness (HV). Results showed significant differences in interblock homogeneity of σf, Ef and Ur for TET, KAT, CER and ENA. In addition, significant differences in interblock homogeneity of HV for TET, CER and GRN were found. Moreover, significant differences in intrablock homogeneity of σf, Ef and Ur were found for KAT, CER, GRN and ENA, as well as for HV of all the tested materials except CER. Weibull modulus was highest for GRN, followed by ENA, KAT, TET then CER.
Collapse
Affiliation(s)
- Maher Eldafrawy
- Dental Biomaterials Research Unit (d-BRU), Institute of Dentistry, University of Liège (ULiège)
- Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège Hospital (CHU)
| | - Yousef Karevan
- Dental Biomaterials Research Unit (d-BRU), Institute of Dentistry, University of Liège (ULiège)
| | - Jean-François Nguyen
- Innovative Dental Materials and Interfaces Research Unit (UR 4462), Université Paris Cité
| | - Amélie Mainjot
- Dental Biomaterials Research Unit (d-BRU), Institute of Dentistry, University of Liège (ULiège)
- Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège Hospital (CHU)
| |
Collapse
|
7
|
Cahyanto A, Martins MVS, Bianchi O, Sudhakaran DP, Sililkas N, Echeverrigaray SG, Rosa V. Graphene oxide increases PMMA's resistance to fatigue and strength degradation. Dent Mater 2023; 39:763-769. [PMID: 37400298 DOI: 10.1016/j.dental.2023.06.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 06/14/2023] [Accepted: 06/14/2023] [Indexed: 07/05/2023]
Abstract
OBJECTIVES to characterize the effects of graphene oxide (GO) on polymethyl methacrylate's (PMMA) reliability and lifetime. The hypothesis tested was that GO would increase both Weibull parameters and decreased strength degradation over time. METHODS PMMA disks containing GO (0.01, 0.05, 0.1, or 0.5 wt%) were subjected to a biaxial flexural test to determine the Weibull parameters (m: modulus of Weibull; σ0: characteristic strength; n = 30 at 1 MPa/s) and slow crack growth (SCG) parameters (n: subcritical crack growth susceptibility coefficient, σf0: scaling parameter; n = 10 at 10-2, 10-1, 101, 100 and 102 MPa/s). Strength-probability-time (SPT) diagrams were plotted by merging SCG and Weibull parameters. RESULTS There was no significant difference in the m value of all materials. However, 0.5 GO presented the lowest σ0, whereas all other groups were similar. The lowest n value obtained for all GO-modified PMMA groups (27.4 for 0.05 GO) was higher than the Control (15.6). The strength degradation predicted after 15 years for Control was 12%, followed by 0.01 GO (7%), 0.05 GO (9%), 0.1 GO (5%), and 0.5 GO (1%). SIGNIFICANCE The hypothesis was partially accepted as GO increased PMMA's fatigue resistance and lifetime but did not significantly improve its Weibull parameters. GO added to PMMA did not significantly affect the initial strength and reliability but significantly increased PMMA's predicted lifetime. All the GO-containing groups presented higher resistance to fracture at all times analyzed compared with the Control, with the best overall results observed for 0.1 GO.
Collapse
Affiliation(s)
- Arief Cahyanto
- Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Malaysia; Department of Dental Materials Science and Technology, Faculty of Dentistry, Padjadjaran University, Indonesia.
| | | | - Otavio Bianchi
- Departamento de Engenharia de Materiais, Universidade Federal do Rio Grande do Sul, Brazil.
| | | | - Nikolaos Sililkas
- Biomaterials Science, Division of Dentistry, School of Medical Sciences, University of Manchester, UK.
| | | | - Vinicius Rosa
- Centre for Advanced 2D Materials, National University of Singapore, Singapore; Faculty of Dentistry, National University of Singapore, 9 Lower Kent Ridge Rd, Singapore 119085, Singapore; ORCHIDS: Oral Care Health Innovations and Designs Singapore, National University of Singapore, 9 Lower Kent Ridge Rd, 119085, Singapore.
| |
Collapse
|
8
|
Topa-Skwarczyńska M, Jankowska M, Gruchała-Hałat A, Petko F, Galek M, Ortyl J. High-performance photoinitiating systems for new generation dental fillings. Dent Mater 2023; 39:729. [PMID: 37393151 DOI: 10.1016/j.dental.2023.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 06/10/2023] [Accepted: 06/14/2023] [Indexed: 07/03/2023]
Abstract
OBJECTIVES To obtain new generation dental composites with improved performance properties compared to currently available dental fillings on the market and to determine the influence of new initiating systems on final product parameters such as degree of cure, hardness, color, and shrinkage. METHODS In order to verify the effectiveness of the developed initiating systems, typical spectroscopic, electrochemical, and kinetic studies using the real-time FT-IR method were shown. Moreover, paste dental fillings were prepared, the compositions were irradiated with the dental lamp, and the degrees of cross-linking were measured by Raman spectroscopy. The polymerization shrinkage was also determined using the rheometer. In addition, their hardness was examined on the Shore scale. Finally, the color analysis of the composites in the L*a*b* color space was compared with the VITA CLASSIC colorant. RESULTS It was shown that, due to their excellent spectroscopic and electrochemical properties, new quinazolin-2-one can act as co-initiators in cationic and radical photopolymerization. It was demonstrated that the most effective composite containing the initiator system in the form of 3-SCH3Ph-Q, IOD, MDEA, and an inorganic filler as nanometric silica and a bonding agent is cured more than 90% after just 1 cycle of dental lamp exposure (30 s), the hardness of the composite after curing on the Shor Scale is 82 ± 4, and the polymerization shrinkage is less than 2.8%. SIGNIFICANCE The article demonstrates effective new initiator systems as an alternative to CQ/amine for obtaining new-generation dental composites. The developed dental composites are a big competition to the currently used dental fillings on the market.
Collapse
Affiliation(s)
- Monika Topa-Skwarczyńska
- Department of Biotechnology and Physical Chemistry, Faculty of Chemical Engineering and Technology, Cracow University of Technology, Warszawska 24, 30-155 Cracow, Poland; Photo4Chem Ltd., Lea 114, 30-133 Cracow, Poland.
| | - Magdalena Jankowska
- Department of Biotechnology and Physical Chemistry, Faculty of Chemical Engineering and Technology, Cracow University of Technology, Warszawska 24, 30-155 Cracow, Poland
| | - Alicja Gruchała-Hałat
- Department of Biotechnology and Physical Chemistry, Faculty of Chemical Engineering and Technology, Cracow University of Technology, Warszawska 24, 30-155 Cracow, Poland
| | - Filip Petko
- Department of Biotechnology and Physical Chemistry, Faculty of Chemical Engineering and Technology, Cracow University of Technology, Warszawska 24, 30-155 Cracow, Poland; Photo HiTech Ltd., Bobrzyńskiego 14, 30-348 Cracow, Poland
| | - Mariusz Galek
- Photo HiTech Ltd., Bobrzyńskiego 14, 30-348 Cracow, Poland
| | - Joanna Ortyl
- Department of Biotechnology and Physical Chemistry, Faculty of Chemical Engineering and Technology, Cracow University of Technology, Warszawska 24, 30-155 Cracow, Poland; Photo HiTech Ltd., Bobrzyńskiego 14, 30-348 Cracow, Poland; Photo4Chem Ltd., Lea 114, 30-133 Cracow, Poland.
| |
Collapse
|
9
|
Mizobuchi S, Kato T, Yamada B, Kan K, Ohtani M, Kobiro K. Influence of the nanostructural characteristics of inorganic fillers on the physical properties of resin cements. Dent Mater J 2023; 42:291-299. [PMID: 36624076 DOI: 10.4012/dmj.2022-164] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Light-curing resin cements, each comprising one of five different inorganic fillers (non-porous and porous spherical SiO2 particles, irregularly shaped glass and ZrO2 particles, and porous ZrO2 spheres), monomers, and polymerization initiators were prepared to determine the effect of filler morphology on the adhesive strength of the resin cement. The strength of adhesion to a computer-aided design/computer-aided manufacturing (CAD/CAM) resin block was investigated mechanically by measuring the tensile bond strength, flexural strength, and elastic modulus. The resin cement containing sub-micron porous ZrO2 spheres had significantly higher tensile bond strength than the other resin cements. The resin cement containing the porous ZrO2 spheres had markedly lower flexural strength and elastic modulus values than the resin cements containing SiO2 and glass fillers.
Collapse
Affiliation(s)
- Shingo Mizobuchi
- Graduate School of Engineering, Kochi University of Technology.,YAMAKIN Co., Ltd
| | | | | | - Kai Kan
- Graduate School of Engineering, Kochi University of Technology.,Graduate School of Advanced Science and Technology, Japan Advanced Institute of Science and Technology
| | - Masataka Ohtani
- Graduate School of Engineering, Kochi University of Technology.,Center for Structural Nanochemistry, Research Institute of Kochi University of Technology
| | - Kazuya Kobiro
- Graduate School of Engineering, Kochi University of Technology.,Center for Structural Nanochemistry, Research Institute of Kochi University of Technology
| |
Collapse
|
10
|
Monomers Release from Direct and Indirect Resin-Based Restorations after Immersion in Common Beverages. Polymers (Basel) 2022; 14:polym14235158. [PMID: 36501552 PMCID: PMC9735919 DOI: 10.3390/polym14235158] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Revised: 11/16/2022] [Accepted: 11/24/2022] [Indexed: 11/30/2022] Open
Abstract
Impurities or degradation of the components of resin-based materials have been throughout investigated by the dental scientific community. The aim of this study is to examine if there is a release of monomers from resin-based materials when they are immersed in common beverage materials which are consumed by the population in large quantities. Three representative dental materials were used for this study, one resin composite indicated for direct restorations and two Computer Aided Design and Computer Aided Manufacturing (CAD/CAM) materials with different methods of fabrication. Forty specimens were fabricated from each material using a low-speed precision sectioning blade 12 × 14 × 2 mm in size and immersed in wine, coffee or cola for 48 h and 12 days, equivalent to 1 month and 1 year of consumption. The materials released more monomers when the materials were immersed in the wine solution (p < 0.05). CAD/CAM materials release less monomers compared to the resin composite material indicated for direct restorations (p < 0.05). The CAD/CAM materials leach a limited quantity of monomers when they are immersed in common beverages due to the manufacturing process which includes high-temperature/high-pressure polymerization.
Collapse
|
11
|
Biodegradation of Dental Resin-Based Composite—A Potential Factor Affecting the Bonding Effect: A Narrative Review. Biomedicines 2022; 10:biomedicines10092313. [PMID: 36140414 PMCID: PMC9496159 DOI: 10.3390/biomedicines10092313] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Revised: 09/04/2022] [Accepted: 09/15/2022] [Indexed: 12/02/2022] Open
Abstract
In recent years, although resin composite has played an important role in the restoration of tooth defects, it still has several disadvantages, including being biodegraded by saliva, bacteria and other enzymes in the oral cavity, which may result in repair failure. This factor is not conducive to the long-term survival of the prosthesis in the mouth. In this article, we review the causes, influencing factors and prevention methods of resin biodegradation. Biodegradation is mainly caused by esterase in saliva and bacteria, which breaks the ester bond in resin and causes the release of monomers. The mechanical properties of the prosthesis can then be affected. Meanwhile, cathepsin and MMPs are activated on the bonding surface, which may decompose the dentin collagen. In addition, neutrophils and residual water on the bonding surface can also aggravate biodegradation. Currently, the primary methods to prevent biodegradation involve adding antibacterial agents to resin, inhibiting the activity of MMPs and enhancing the crosslinking of collagen fibers. All of the above indicates that in the preparation and adhesion of resin materials, attention should be paid to the influence of biodegradation to improve the prosthesis’s service life in the complex environment of the oral cavity.
Collapse
|
12
|
Lassila L, Mangoush E, Vallittu PK, Garoushi S. Fracture behavior of discontinuous fiber-reinforced composite inlay-retained fixed partial denture before and after fatigue aging. J Prosthodont Res 2022; 67:271-277. [PMID: 35896342 DOI: 10.2186/jpr.jpr_d_22_00050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To evaluate the fracture behavior of inlay-retained fixed partial dentures (IRFPDs) made of experimental short fiber-reinforced composite (SFRC) computer-aided design/computer-aided manufacturing (CAD/CAM) block before and after cyclic fatigue aging. METHODS Five groups (n=20/group) of three-unit posterior IRFPDs were fabricated. The first and second groups were CAD/CAM fabricated from experimental SFRC blocks or lithium-disilicate (IPS e.max CAD, IVOCLAR) materials, the third group comprised a three-dimensional-printed composite (Temp PRINT, GC), and the fourth and fifth groups comprised conventional laboratory flowable composite (Gradia Plus, GC) and commercial flowable SFRC (everX Flow, GC), respectively. All IRFPDs were luted into a metal jig with adhesive dual-cure resin cement (RelyX Ultimate, 3M ESPE). Half the IRFPDs per group (n=10) were subjected to fatigue aging for 10,000 cycles. The remaining half were statically loaded until fracture without fatigue aging. The load was applied vertically between triangular ridges of the buccal and lingual cusps. The fracture mode was visually examined using optical and scanning electron microscopy (SEM). Data were statistically analyzed using a two-way analysis of variance (ANOVA) followed by Tukey's HSD test. RESULTS ANOVA revealed that IRFPDs made of experimental SFRC CAD/CAM had the highest (p<0.05) load-bearing capacity before (2624±463 N) and after (2775±297 N) aging among all groups. Cyclic fatigue aging decreased the load-bearing capacity (p>0.05) of all tested prostheses, except for the experimental SFRC CAD/CAM and conventional laboratory composite IRFPDs (p>0.05). SEM images showed the ability of discontinuous short fibers in the experimental SFRC CAD/CAM composite to redirect and hinder crack propagation. CONCLUSION CAD/CAM-fabricated IRFPDs made of experimental SFRC blocks showed promising performance in clinical testing in terms of fracture behavior.
Collapse
Affiliation(s)
- Lippo Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre -TCBC Institute of Dentistry, University of Turku, Turku, Finland
| | - Enas Mangoush
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre -TCBC Institute of Dentistry, University of Turku, Turku, Finland
| | - Pekka K Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre -TCBC Institute of Dentistry, University of Turku, Turku, Finland.,City of Turku Welfare Division, Oral Health Care, Turku, Finland
| | - Sufyan Garoushi
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre -TCBC Institute of Dentistry, University of Turku, Turku, Finland
| |
Collapse
|
13
|
Li H, Sakai T, Tanaka A, Ogura M, Lee C, Yamaguchi S, Imazato S. Interpretable AI Explores Effective Components of CAD/CAM Resin Composites. J Dent Res 2022; 101:1363-1371. [DOI: 10.1177/00220345221089251] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
High flexural strength of computer-aided manufacturing resin composite blocks (CAD/CAM RCBs) are required in clinical scenarios. However, the conventional in vitro approach of modifying materials’ composition by trial and error was not efficient to explore the effective components that contribute to the flexural strength. Machine learning (ML) is a powerful tool to achieve the above goals. Therefore, the aim of this study was to develop ML models to predict the flexural strength of CAD/CAM RCBs and explore the components that affect flexural strength as the first step. The composition of 12 commercially available products and flexural strength were collected from the manufacturers and literature. The initial data consisted of 16 attributes and 12 samples. Considering that the input data for each sample were recognized as a multidimensional vector, a fluctuation range of 0.1 was proposed for each vector and the number of samples was augmented to 120. Regression algorithms—that is, random forest (RF), extra trees, gradient boosting decision tree, light gradient boosting machine, and extreme gradient boosting—were used to develop 5 ML models to predict flexural strength. An exhaustive search and feature importance analysis were conducted to analyze the effective components that affected flexural strength. The R2 values for each model were 0.947, 0.997, 0.998, 0.983, and 0.927, respectively. The relative errors of all the algorithms were within 15%. Among the high predicted flexural strength group in the exhaustive search, urethane dimethacrylate was contained in all compositions. Filler content and triethylene glycol dimethacrylate were the top 2 features predicted by all models in the feature importance analysis. ZrSiO4 was the third important feature for all models, except the RF model. The ML models established in this study successfully predicted the flexural strength of CAD/CAM RCBs and identified the effective components that affected flexural strength based on the available data set.
Collapse
Affiliation(s)
- H. Li
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - T. Sakai
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - A. Tanaka
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - M. Ogura
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - C. Lee
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - S. Yamaguchi
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - S. Imazato
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| |
Collapse
|
14
|
Alamoush RA, Salim NA, Silikas N, Satterthwaite JD. Long-term hydrolytic stability of CAD/CAM composite blocks. Eur J Oral Sci 2021; 130:e12834. [PMID: 34897842 DOI: 10.1111/eos.12834] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 09/29/2021] [Indexed: 01/17/2023]
Abstract
This study aimed to assess water sorption and solubility of CAD/CAM composite blocks compared to CAD/CAM ceramic after 8 months storage in water and artificial saliva. Eight CAD/CAM blocks were investigated: Five resin-composite blocks (RCBs), one polymer-infiltrated ceramic network (PICN) block, one ceramic-filled polyetheretherketone (PEEK) block, and one feldspathic ceramic block. One hundred and twelve specimens were prepared comprising 14 specimens of each of the eight materials. From each group of specimens, seven randomly selected specimens were immersed in 10 mL of water, while the other seven specimens were immersed in artificial saliva. All specimens were stored at 37°C and weighed at various time intervals. The data were analysed via repeat measures ANOVA, one-way ANOVA and Tukey's post hoc test (α = 0.05 for all tests). Sorption values (mean [SD]) in water were within the range -1.21 (0.4) to 39.3 (2.1) μg/mm3 and in artificial saliva between -0.7 (0.2) and 41.6 (1.3) μg/mm3 . Solubility values in water were between -0.43 (0.08) and 0.34 (0.18) μg/mm3 and in artificial saliva between -0.53 (0.07) μg/mm3 and 0.33 (0.2) μg/mm3 . CAD/CAM composite blocks were hydrolytically stable under long-term storage (according to ISO 4949:2009), although not as stable as ceramic. Water sorption of CAD/CAM composite blocks was dependent on the resin-matrix and was influenced by the filler weight %.
Collapse
Affiliation(s)
- Rasha A Alamoush
- Prosthodontics Department, School of Dentistry, University of Jordan, Amman, Jordan.,Dentistry, School of Medical Sciences, The University of Manchester, Manchester, UK
| | - Nesreen A Salim
- Prosthodontics Department, School of Dentistry, University of Jordan, Amman, Jordan
| | - Nick Silikas
- Dentistry, School of Medical Sciences, The University of Manchester, Manchester, UK
| | | |
Collapse
|
15
|
Nagasawa Y, Eda Y, Shigeta H, Ferrari M, Nakajima H, Hibino Y. Effect of sandblasting and/or priming treatment on the shear bond strength of self-adhesive resin cement to CAD/CAM blocks. Odontology 2021; 110:70-80. [PMID: 34272634 DOI: 10.1007/s10266-021-00635-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Accepted: 06/24/2021] [Indexed: 11/30/2022]
Abstract
The aim of this study was to investigate the effect of two different priming agents and/or sandblasting on the shear bond strength of self-adhesive resin cement to the resin composite for core build-up to CAD/CAM blocks. A CAD/CAM ceramic block (GN I CERAMIC BLOCK, GC) and a CAD/CAM resin composite block (CERASMART 270, GC), a self-adhesive resin cement (G-CEM ONE, GC) and two different primers, i.e., a multipurpose primer (MP; G-Multi Primer, GC) and a ceramic primer (CP; Ceramic Primer II, GC), were examined. Five different surface treatments with priming and/or sandblasting and no surface treatment (control) were performed on the block. Disk specimens (6 mm in diameter and 4 mm in thickness) made from core composites were cemented to the blocks after the surface treatments. Then, the 24-h shear bond strength of the resin cement between the block and the resin composite core was determined (n = 15). Sandblasted specimens had greater bond strength than controls for both blocks (p < 0.05). Priming to both blocks significantly increased the bond strength of resin cement compared to that of controls (p < 0.05). Although Weibull moduli were not significantly changed among all surface treatments for both blocks, the strengths with 5% and 95% failure probability of sandblasted and/or primed blocks were estimated to be greater than those of controls. The combination of priming and sandblasting to the CAD/CAM composite and ceramic surface was effective in increasing the bond strength of the resin cement.
Collapse
Affiliation(s)
- Yuko Nagasawa
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1, Keyakidai, Sakado, Saitama, 350-0283, Japan.
| | - Yoshikazu Eda
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1, Keyakidai, Sakado, Saitama, 350-0283, Japan
| | - Hirotaka Shigeta
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1, Keyakidai, Sakado, Saitama, 350-0283, Japan
| | - Marco Ferrari
- Department of Prosthodontics and Dental Materials, School of Dental Medicine, University of Siena, Viale Mario Bracci, 16, Siena, Italy
| | - Hiroshi Nakajima
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1, Keyakidai, Sakado, Saitama, 350-0283, Japan
| | - Yasushi Hibino
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1, Keyakidai, Sakado, Saitama, 350-0283, Japan
| |
Collapse
|
16
|
The effect of different storage media on the monomer elution and hardness of CAD/CAM composite blocks. Dent Mater 2021; 37:1202-1213. [PMID: 33962792 DOI: 10.1016/j.dental.2021.04.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 03/29/2021] [Accepted: 04/24/2021] [Indexed: 11/20/2022]
Abstract
OBJECTIVE This study aimed to assess the effect of different storage media on the hardness and monomer elution of CAD/CAM composite blocks. METHODS Five resin-composite blocks (RCB), one polymer-infiltrated ceramic network (PICN) block (Enamic (EN)), one ceramic-filled poly ether ether ketone (PEEK) block (Dentokeep (DK)), and one feldspathic ceramic block. Microhardness was measured using a Vickers indenter tester (FM-700, Future Tech Corp., Japan). In addition 4 conventional resin-composites were investigated for monomer elution using high performance liquid chromatography (HPLC) after storage in different media for 3 months. The data were analysed by three-way ANOVA, two-way ANOVA, one-way ANOVA, Tukey's post hoc test and the independent t-test (α=0.05 for all tests). RESULTS The specimens stored in the water had a hardness reduction ranging from 0.9% to 24.4%. In artificial saliva, the specimens had a hardness reduction ranging from 2.8% to 23.2%. The hardness reduction percentage in 75% Ethanol/Water (E/W) ranged between 3.8% and 35.3%. All materials, except GR (resin-composite block) and DK (Polyetheretherketone (PEEK)), showed a variable extent of monomer elution into 75% E/W with significantly higher amounts eluted from conventional composites. GRA and GND (conventional resin-composites) eluted TEGDMA in artificial saliva and GRA eluted TEGDMA in water. SIGNIFICANCE The hardness of CAD/CAM composite blocks was affected by different storage media, and they were not as stable as ceramic, with PICN exhibited superior hardness stability to all of the resin-composite blocks in all the storage media and was comparable to ceramic block. The hardness reduction percentage of the CAD/CAM composite blocks was influenced by the filler loading and resin-matrix composition.Minimal or no monomer elution from CAD/CAM blocks was detected.
Collapse
|
17
|
Mechanical degradation of contemporary CAD/CAM resin composite materials after water ageing. Dent Mater 2021; 37:1156-1167. [PMID: 33933272 DOI: 10.1016/j.dental.2021.04.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 03/29/2021] [Accepted: 04/08/2021] [Indexed: 11/22/2022]
Abstract
OBJECTIVE The aim of the present study was to assess the effect of water storage on the quasi-static properties and cyclic fatigue behavior of four contemporary CAD/CAM resin composite materials. METHODS The CAD/CAM resin composites Grandio Blocs, LavaTM Ultimate, CerasmartTM and Brilliant Crios, as well as the direct resin composite Grandio SO, were evaluated. Rectangular plates were cut from the blocks or fabricated using a silicon mold to obtain specimens for fracture toughness (KIc, n = 10), biaxial strength (σ0, n = 30) and cyclic fatigue testing (n = 30). Half of the specimens was stored for 24 h in dry conditions and the other half was aged for 60 days in distilled water at 37 °C. KIc was determined using the Compact-Tension (C(T)) method and σ0 and cyclic fatigue were tested using the Ball-on-Three-Balls assembly. Additional disc-shaped specimens (n = 5) were produced to obtain water sorption curves of the materials. Weibull statistics and two-way ANOVA with Tukey's post-hoc test were used for data assessment. RESULTS The highest water sorption was observed for LavaTM Ultimate (42.6 μg/mm3), whereas Grandio SO displayed the lowest uptake (14 μg/mm3). A statistically significant drop in KIc and σ0 was measured for all materials after water storage, except for the σ0 of CerasmartTM. Water ageing had a dissimilar effect on the cyclic fatigue behavior, increasing the slow crack growth susceptibility of LavaTM Ultimate, but decreasing it for CerasmartTM and Brilliant Crios. SIGNIFICANCE Contemporary CAD/CAM resin composites are susceptible to water driven degradative processes, although differences in filler content and resin matrix constitution play an important role in how it impacts their mechanical properties.
Collapse
|
18
|
Abdou A, Takagaki T, Alghamdi A, Tichy A, Nikaido T, Tagami J. Bonding performance of dispersed filler resin composite CAD/CAM blocks with different surface treatment protocols. Dent Mater J 2020; 40:209-219. [PMID: 33162457 DOI: 10.4012/dmj.2020-049] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The effect of various pretreatments on the bonding of a resin cement to resin-composite CAD/CAM blocks (RCBs) was examined. The surface of dispersed-filler RCBs (DF-RCBs) and a polymer infiltrated ceramic network RCB (PICN-RCB) was roughened using hydrofluoric acid etching (HF) or sandblasting, and followed by silanization and/or universal adhesive (UA) application. Microtensile bond strength (µTBS), surface roughness parameters (arithmetical mean height (Sa); developed interfacial area ratio (Sdr)), and critical surface energy (γc) were determined. For most DF-RCBs, the highest µTBS was obtained using HF+UA. UA application to DF-RCBs resulted in similar or higher µTBS compared to silanization, which indicates that silane treatment is not crucial for DF-RCBs, especially after HF. In contrast, the highest µTBS to PICN-RCB was obtained with silanization. Both roughening pretreatments significantly increased the surface roughness parameters and the γc of all RCBs. The γc was positively correlated with Sa (r=0.756, p<0.001) and Sdr (r=0.837, p<0.001).
Collapse
Affiliation(s)
- Ahmed Abdou
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University.,Biomaterials Department, Faculty of Oral and Dental Medicine, Modern University for Technology and Information
| | - Tomohiro Takagaki
- Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University
| | - Ali Alghamdi
- Al-Mikwah Dental Center, Saudi Ministry of Health
| | - Antonin Tichy
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University.,Institute of Dental Medicine, First Faculty of Medicine of the Charles University and General University Hospital in Prague
| | - Toru Nikaido
- Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University
| | - Junji Tagami
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| |
Collapse
|
19
|
Nagasawa Y, Hibino Y, Eda Y, Nakajima H. Effect of surface treatment of CAD/CAM resin composites on the shear bond strength of self-adhesive resin cement. Dent Mater J 2020; 40:364-378. [PMID: 33100298 DOI: 10.4012/dmj.2019-431] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study examined the effects of sandblasting, hydrofluoric acid etching and priming on the shear bond strength of self-adhesive resin cement between seven different CAD/CAM resin composites and a resin composite core material at 24-h after cement mixing. Five surface treatments [control (C), sandblasting (S), priming (P), sandblasting with priming (SP), and 9% HF etching with priming (HFP)] were performed respectively for disc specimens of CAD/CAM blocks. There were no significant differences in bond strength among the C, S, and P, except for one block (p>0.05). SP showed a greater bond strength than S. Weibull moduli were not changed significantly among all treatments for all blocks, whereas the strengths with 5% and 95% failure probability of SP and HFP showed greater values than the others. The bond strengths of HFP were comparable to those of SP. Priming after sandblasting or HF etching could be effective to increase the bond strength of CAD/CAM blocks.
Collapse
Affiliation(s)
- Yuko Nagasawa
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry
| | - Yasushi Hibino
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry
| | - Yoshikazu Eda
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry
| | - Hiroshi Nakajima
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry
| |
Collapse
|
20
|
Color Stability of Dental Reinforced CAD/CAM Hybrid Composite Blocks Compared to Regular Blocks. MATERIALS 2020; 13:ma13214722. [PMID: 33105868 PMCID: PMC7660196 DOI: 10.3390/ma13214722] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 10/19/2020] [Accepted: 10/20/2020] [Indexed: 11/17/2022]
Abstract
This study compares the color stability of dental reinforced computer-aided design/computer-aided manufacturing (CAD/CAM) hybrid composite blocks to that of regular blocks. One hundred fifty disc-type specimens (n = 15) were prepared from five sets of hybrid composite blocks (Cerasmart-200/Cerasmart-300, KZR-CAD HR/KZR-CAD HR3, Estelite Block/ Estelite-P Block, Avencia Block/Avencia-P Block, Mazic Duro/Duro Ace). The specimen color and translucency parameter (TP) were assessed using a spectrophotometer before and after immersion in staining solutions (water, 10% ethanol, simulated red wine). Changes in color (ΔE) and translucency (ΔTP) of specimens were calculated. The data were analyzed using the analysis of variance (ANOVA) and Tukey’s post hoc test (p < 0.05). Microstructural features of the hybrid composite blocks were also examined using FE-SEM. Immersion in deionized water or 10% ethanol made no significant color or translucency changes (except for Avencia-P Block); however, the simulated red wine caused significant changes to the color and translucency of almost all specimens, especially after 4 weeks of immersion. The reinforced hybrid blocks (except for Estelite-P Block and Duro Ace) showed lower color stability than corresponding regular blocks. Avencia-P Block showed significantly reduced color stability compared to Avencia Block. Even in deionized water and 10% ethanol, Avencia-P Block showed perceptible ΔE and decreased translucency. Estelite Block/ Estelite-P Block and Mazic Duro/Duro Ace showed better color stability than the other materials tested.
Collapse
|
21
|
KANG L, ZHOU Y, LAN J, YU Y, CAI Q, YANG X. Effect of resin composition on performance of polymer-infiltrated feldspar-network composites for dental restoration. Dent Mater J 2020; 39:900-908. [DOI: 10.4012/dmj.2019-180] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Longzhao KANG
- State Key Laboratory of Organic-Inorganic Composites, Beijing Laboratory of Biomedical Materials, Beijing University of Chemical Technology
| | - Yan ZHOU
- State Key Laboratory of Organic-Inorganic Composites, Beijing Laboratory of Biomedical Materials, Beijing University of Chemical Technology
| | - Jinle LAN
- State Key Laboratory of Organic-Inorganic Composites, Beijing Laboratory of Biomedical Materials, Beijing University of Chemical Technology
| | - Yunhua YU
- State Key Laboratory of Organic-Inorganic Composites, Beijing Laboratory of Biomedical Materials, Beijing University of Chemical Technology
| | - Qing CAI
- State Key Laboratory of Organic-Inorganic Composites, Beijing Laboratory of Biomedical Materials, Beijing University of Chemical Technology
| | - Xiaoping YANG
- State Key Laboratory of Organic-Inorganic Composites, Beijing Laboratory of Biomedical Materials, Beijing University of Chemical Technology
| |
Collapse
|
22
|
Topa M, Ortyl J. Moving Towards a Finer Way of Light-Cured Resin-Based Restorative Dental Materials: Recent Advances in Photoinitiating Systems Based on Iodonium Salts. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E4093. [PMID: 32942676 PMCID: PMC7560344 DOI: 10.3390/ma13184093] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 09/03/2020] [Accepted: 09/10/2020] [Indexed: 02/06/2023]
Abstract
The photoinduced polymerization of monomers is currently an essential tool in various industries. The photopolymerization process plays an increasingly important role in biomedical applications. It is especially used in the production of dental composites. It also exhibits unique properties, such as a short time of polymerization of composites (up to a few seconds), low energy consumption, and spatial resolution (polymerization only in irradiated areas). This paper describes a short overview of the history and classification of different typical monomers and photoinitiating systems such as bimolecular photoinitiator system containing camphorquinone and aromatic amine, 1-phenyl-1,2-propanedione, phosphine derivatives, germanium derivatives, hexaarylbiimidazole derivatives, silane-based derivatives and thioxanthone derivatives used in the production of dental composites with their limitations and disadvantages. Moreover, this article represents the challenges faced when using the latest inventions in the field of dental materials, with a particular focus on photoinitiating systems based on iodonium salts. The beneficial properties of dental composites cured using initiation systems based on iodonium salts have been demonstrated.
Collapse
Affiliation(s)
- Monika Topa
- Faculty of Chemical Engineering and Technology, Cracow University of Technology, Warszawska 24, 31-155 Cracow, Poland
| | - Joanna Ortyl
- Faculty of Chemical Engineering and Technology, Cracow University of Technology, Warszawska 24, 31-155 Cracow, Poland
- Photo HiTech Ltd., Bobrzyńskiego 14, 30-348 Cracow, Poland
| |
Collapse
|
23
|
Bahadır HS, Bayraktar Y. Evaluation of the repair capacities and color stabilities of a resin nanoceramic and hybrid CAD/CAM blocks. J Adv Prosthodont 2020; 12:140-149. [PMID: 32601533 PMCID: PMC7314625 DOI: 10.4047/jap.2020.12.3.140] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 04/02/2020] [Accepted: 04/28/2020] [Indexed: 11/08/2022] Open
Abstract
PURPOSE This study evaluated the color stabilities of two computer-aided design and computer-aided manufacturing (CAD/CAM) blocks and a nanofill composite resin and the microtensile bond strength (µTBS) between the materials. MATERIALS AND METHODS Twelve specimens of 4 mm height were prepared for both Lava Ultimate (L) and Vita Enamic (E) CAD/CAM blocks. Half of the specimens were thermocycled (10,000 cycle, 5° to 55℃) for each material. Both thermocycled and non-thermocycled specimens were surface treated with one of the three different methods (Er,Cr:YSGG laser, bur, or control). For each surface treatment group, one of the thermocycled and one of non-thermocycled specimens were restored using silane (Ceramic Primer II), universal adhesive (Single Bond Universal), and nanofill composite resin of 4-mm height (Filtek Ultimate). The other specimens were restored with the same procedure without using silane. For each group, 1 × 1 × 8 mm bar specimens were prepared using a microcutting device. Bar specimens were thermocycled (10,000 cycle, 5° to 55℃) and microtensile tests were performed. Staining of the materials in coffee solution was also compared using a spectrophotometer. Data were analyzed using one-way ANOVA, t-test and post-hoc Scheffe tests. RESULTS µTBS were found similar between the thermocycled and non-thermocycled groups (P>.05). The highest µTBS (20.818 MPa) was found in the non-thermocycled, bur-ground, silane-applied E group. Silane increased µTBS at some E groups (P<.05). Composite resin specimens showed more staining than CAD/CAM blocks (P<.05). CONCLUSION CAD/CAM blocks can be repaired with composite resins after proper surface treatments. Using silane is recommended in repair process. Color differences may be shown between CAD/CAM blocks and the nanofill composite after a certain time period.
Collapse
Affiliation(s)
- Hasibe Sevilay Bahadır
- Department of Restorative Dentistry, Faculty of Dentistry, Yıldırım Beyazıt University, Ankara, Turkey
| | - Yusuf Bayraktar
- Department of Restorative Dentistry, Faculty of Dentistry, Kırıkkale University, Kırıkkale, Turkey
| |
Collapse
|
24
|
Kim JE, Lim JH, Kang YJ, Kim JH, Shim JS. Effect of Pressure and Particle Size During Aluminum Oxide Air Abrasion on the Flexural Strength of Disperse-Filled Composite and Polymer-Infiltrated Ceramic Network Materials. Polymers (Basel) 2020; 12:polym12061396. [PMID: 32580368 PMCID: PMC7362000 DOI: 10.3390/polym12061396] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 06/12/2020] [Accepted: 06/19/2020] [Indexed: 11/16/2022] Open
Abstract
Esthetic dental computer-aided design/computer-aided manufacturing (CAD/CAM) polymers such as disperse-filled composites (DFC) and polymer-infiltrated ceramic networks (PICN) should be subjected to surface treatment before bonding. However, such treatment can lead to defect formation and a decrease in strength. Therefore, in this study, we compared the flexural strengths of DFC and PICN materials air-abraded with alumina particles of different sizes at different pressures. In addition to Weibull analysis, the samples (untreated and treated) were characterized by scanning electron microscopy and atomic force microscopy. Both DFC and PICN exhibited the lowest flexural strength at large particle sizes and high pressures. Therefore, we optimized the air abrasion parameters to maintain the flexural strength and significantly increase surface roughness. In the case of DFC, the optimal particle size and pressure conditions were 50 µm at 2 bar and 110 µm at 1 bar, while for PICN, the best performance was obtained using Al2O3 particles with a size of 50 µm at 1 bar. This study reveals that optimization of the surface treatment process is crucial in the fabrication of high-performance clinical materials for dental restorations.
Collapse
|
25
|
Barutcigil K, Dündar A, Batmaz SG, Yıldırım K, Barutçugil Ç. Do resin-based composite CAD/CAM blocks release monomers? Clin Oral Investig 2020; 25:329-336. [PMID: 32488490 DOI: 10.1007/s00784-020-03377-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Accepted: 05/25/2020] [Indexed: 12/15/2022]
Abstract
OBJECTIVE The present study aimed to identify and quantify the elution of monomers of five different resin-based CAD/CAM blocks (RCBs) using HPLC. METHODS Five different RCBs were used in the study: GC Cerasmart (CS), Voco Grandio blocs (GR), 3M Lava Ultimate (LU), Shofu Block (SB), and Vita Enamic (VE). Fifteen samples from each material were prepared using a low-speed precision diamond saw (ISOMET Buehler, Lake Bluff, IL, USA) at 5 × 5 × 4 mm size. After the preparation of samples, an extraction solution was mixed with %75/%25 ethanol/water. The samples were stored in the amber-colored bottles during three different immersed periods as 1 h, 24 h, and 90 days (n = 5). After immersion, 0.5 ml solutions were taken from each bottle and analyzed using HPLC. RESULTS A total of 16.7 μg/ml of monomers from SB, 13.4 μg/ml of monomers from GR, 13.2 μg/ml of monomers from CS, and 6.7 μg/ml of monomers from LU were found after 3-m immersion. TEGDMA after 3-m of immersion was only released from the SB group, and also BisEMA was released from the CS group. Among the specimens immersed for 1 h, UDMA was released the least from the LU group and the most from the GR group (p < 0.05). Correspondingly, 24 h and 3 m after immersion, the highest release of monomers was found in the GR (p < 0.05). CONCLUSIONS When the monomer release from RCBs was evaluated, it was shown that these materials released methacrylate-based monomers except VE, especially if they were kept in a solvent solution for a long time such as 3 m. CLINICAL SIGNIFICANCE The novel resin-based CAD/CAM blocks might monomer release, which may cause cytotoxic effects. But, the detected amount of monomer release is below the estimated daily limit.
Collapse
Affiliation(s)
- Kubilay Barutcigil
- Department of Prosthetic Dentistry, Faculty of Dentistry, Akdeniz University, 07058, Antalya, Turkey
| | - Ayşe Dündar
- Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University, 07058, Antalya, Turkey
| | - Sevde Gül Batmaz
- Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University, 07058, Antalya, Turkey
| | - Kardelen Yıldırım
- Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University, 07058, Antalya, Turkey
| | - Çağatay Barutçugil
- Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University, 07058, Antalya, Turkey.
| |
Collapse
|
26
|
Resin composite blocks for dental CAD/CAM applications reduce biofilm formation in vitro. Dent Mater 2020; 36:603-616. [DOI: 10.1016/j.dental.2020.03.016] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2019] [Revised: 02/18/2020] [Accepted: 03/12/2020] [Indexed: 11/23/2022]
|
27
|
Moradi Z, Abbasi M, Khalesi R, Tabatabaei MH, Shahidi Z. Fracture Toughness Comparison of Three Indirect Composite Resins Using 4-Point Flexural Strength Method. Eur J Dent 2020; 14:212-216. [PMID: 32283561 PMCID: PMC7274826 DOI: 10.1055/s-0040-1708438] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Objectives
The advantages of indirect composite restorations such as less crack formation during their computer-aided design/computer-aided manufacturing process, compared with ceramic restorations, have resulted in their growing popularity. However, restoration failure is a major concern with regard to the long-term clinical success of restorations and may occur as the result of propagation of a crack originated from an internal flaw in the restoration. This study aimed to compare the fracture toughness of three indirect composite resins.
Materials and Methods
In this
in vitro
experimental study, 10 specimens measuring 3 × 3 × 18 mm were fabricated of Gradia, Crios, and high impact polymer composite indirect composites. A single edge notch with a diameter < 0.3 mm and 0.3 mm length was created in the 9 mm longitudinal dimension of specimens using a no. 11 surgical scalpel. The specimens were then subjected to 4-point flexural strength test in a universal testing machine with a crosshead speed of 0.1 mm/s until failure.
Statistical Analysis
Data were analyzed using IBM SPSS Statistics via one-way analysis of variance (ANOVA) and Tukey’s HSD (honestly significant difference) test. The statistical power was set at
p
˂ 0.05.
Results
One-way ANOVA showed a significant difference in fracture toughness of the three composite groups (
p
= 0.000). According to the Tukey HSD analysis, the fracture toughness of HIPC was significantly higher than that of the other two composites. The fracture toughness of Gradia was significantly lower among all.
Conclusions
Within the limitations of this study, the results showed that high temperature-pressure polymerization can increase resistance to crack propagation and subsequently improve the clinical service of indirect composite restorations. Although we do not know the filler volume percentage of HIPC, it seems that filler volume percentage of the composite is inversely correlated with fracture toughness.
Collapse
Affiliation(s)
- Zohreh Moradi
- Department of Restorative Dentistry, Tehran University of Medical Science, Tehran, Iran
| | - Mahdi Abbasi
- Department of Restorative Dentistry, Tehran University of Medical Science, Tehran, Iran
| | - Rayhaneh Khalesi
- Department of Restorative Dentistry, Jondishapour University of Medical Science, Ahvaz, Iran
| | | | - Zahra Shahidi
- Department of Restorative Dentistry, Tehran University of Medical Science, Tehran, Iran
| |
Collapse
|
28
|
Kassem IA, Farrag IE, Zidan SM, ElGuindy JF, Elbasty RS. Marginal gap and fracture resistance of CAD/CAM ceramill COMP and cerasmart endocrowns for restoring endodontically treated molars bonded with two adhesive protocols: an in vitro study. Biomater Investig Dent 2020; 7:50-60. [PMID: 32195460 PMCID: PMC7054925 DOI: 10.1080/26415275.2020.1728277] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2019] [Accepted: 01/31/2020] [Indexed: 11/15/2022] Open
Abstract
Endocrowns represent a conservative and esthetic restorative alternative to full coverage crowns. They can be constructed using various CAD/CAM materials that can provide a modulus of elasticity similar to that of teeth. The ability to use of such materials in composite blocks that can be easily repaired is also an advantage, provided appropriate bonding performance is ensured. This study, therefore, evaluated the marginal gap and fracture resistance of two CAD/CAM endocrown materials using two bonding protocols. Thirty-two mandibular molars were evaluated in two groups based on the material type: a Cerasmart group (GC America Inc; n = 16) acting as the control and a Ceramill COMP group (Amann Girrbach, Germany; n = 16). These groups were then classified according to the bonding protocol used: a total-etch bonding protocol (n = 8) and a self-etch bonding protocol (n = 8) implemented using RelyX ultimate adhesive resin cement (3M ESPE). The samples were then subjected to aging by simulating a 1-year thermo-mechanical process. The marginal gap results were statistically insignificant across the material and bonding protocol groups before thermo-mechanical aging. Thermo-mechanical aging significantly reduced the marginal gap distance for Ceramill COMP endocrowns cemented using the total-etch protocol (p = 0.002). No statistically significant difference was recorded for the fracture resistance in either the material or bonding protocol groups (p ≥ 0.05). Both materials and bonding protocols can, therefore, be used in the posterior region providing conservative treatment, adequate marginal gap and fracture resistance.
Collapse
Affiliation(s)
- Israa Atif Kassem
- Department of Fixed Prosthodontics, Faculty of Oral and Dental Medicine, Cairo University, Cairo, Egypt
| | | | - Samir Mahmoud Zidan
- Department of Fixed Prosthodontics, Faculty of Oral and Dental Medicine, Cairo University, Cairo, Egypt
| | - Jylan Fouad ElGuindy
- Department of Fixed Prosthodontics, Faculty of Oral and Dental Medicine, Cairo University, Cairo, Egypt
| | - Reham Said Elbasty
- Department of Fixed Prosthodontics, Faculty of Oral and Dental Medicine, Cairo University, Cairo, Egypt
| |
Collapse
|
29
|
Karaer O, Yamaguchi S, Nakase Y, Lee C, Imazato S. In silico non-linear dynamic analysis reflecting in vitro physical properties of CAD/CAM resin composite blocks. J Mech Behav Biomed Mater 2020; 104:103697. [PMID: 32174439 DOI: 10.1016/j.jmbbm.2020.103697] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 02/07/2020] [Accepted: 02/12/2020] [Indexed: 12/15/2022]
Abstract
PURPOSE The aim of this study was to assess the validity of in silico models of three-point bending tests to reflect in vitro physical properties obtained from three commercially available computer-aided design/computer-aided manufacturing (CAD/CAM) resin composite blocks and demonstrate notchless triangular prism analysis with those properties. MATERIAL AND METHODS Three types of commercially available CAD/CAM resin composite blocks were used: Cerasmart 300 (CS300; GC, Tokyo, Japan), Katana Avencia P Block (AP; Kuraray Noritake Dental, Tokyo, Japan), and KZR CAD HR3 Gamma Theta (GT; Yamakin, Osaka, Japan). In vitro/in silico three-point bending tests were conducted to obtain elastic modulus and fracture strain for non-linear dynamic finite element analysis (n = 10/each). Fractured surfaces of specimens after in vitro NTP tests were observed, and the fracture toughness of each CAD/CAM resin composite was obtained by in silico NTP analysis. RESULTS Both in vitro and in silico load-displacement curves obtained from three-point bending tests were significantly correlated (p < 0.05). The elastic moduli of CS300, AP, and GT were 8.0 GPa, 10.0 GPa, and 9.0 GPa, respectively. The fracture toughness values obtained from in silico NTP analysis of CS300, AP, and GT were 5.057 MPa m1/2, 4.193 MPa m1/2, and 4.880 MPa m1/2, respectively. There was no significant difference in the length of the stable region among the three CAD/CAM resin composites (p = 0.09). CONCLUSIONS The in silico approach established in this study showed acceptable reflection of in vitro physical properties and will be useful for assessing fracture toughness related to the longevity of CAD/CAM resin composites without wastage of materials.
Collapse
Affiliation(s)
- Oğuzcan Karaer
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara, 06560, Turkey
| | - Satoshi Yamaguchi
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan.
| | - Yutaro Nakase
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan; Department of Pediatric Dentistry, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Chunwoo Lee
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Satoshi Imazato
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan; Department of Advanced Functional Materials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| |
Collapse
|
30
|
Evaluation of the Surface Characteristics of Dental CAD/CAM Materials after Different Surface Treatments. MATERIALS 2020; 13:ma13040981. [PMID: 32098305 PMCID: PMC7078785 DOI: 10.3390/ma13040981] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 02/18/2020] [Accepted: 02/20/2020] [Indexed: 11/25/2022]
Abstract
Computer-aided design/computer-aided manufacturing (CAD/CAM) technology was developed to ensure the sufficient strength of tooth restorations, to improve esthetic restorations with a natural appearance and to make the techniques easier, faster and more accurate. In the view of the limited research on the surface treatments of the CAD/CAM materials and the need to evaluate the ideal surface characteristics of a material to achieve the best adhesion to tooth tissues, this study aimed to investigate the surface roughness and morphology of four different CAD/CAM materials using four different surface treatments. The CAD/CAM materials used in this study were three composites (Shofu Block HC, Lava Ultimate and Brilliant Crios) and a hybrid ceramic (Enamic). The surface of the specimens of each material received one of the following treatments: no surface treatment, sandblasting with 29 μm Al2O3 particles, 9% hydrofluoric acid etching and silane application, and the tribochemical method using CoJet System. Surface roughness was evaluated using optical profilometry, and surface morphology was observed by means of scanning electron microscopy. All surface treatments resulted in higher surface roughness values compared to the control group. Different treatments affected the surface properties of the materials, presumably due to discrepancies in their composition and structure.
Collapse
|
31
|
Mourouzis P, Andreasidou E, Samanidou V, Tolidis K. Short-term and long-term release of monomers from newly developed resin-modified ceramics and composite resin CAD-CAM blocks. J Prosthet Dent 2020; 123:339-348. [DOI: 10.1016/j.prosdent.2019.01.012] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Revised: 01/09/2019] [Accepted: 01/09/2019] [Indexed: 11/26/2022]
|
32
|
Tunac AT, Celik EU, Yasa B. Two-year performance of CAD/CAM fabricated resin composite inlay restorations: A randomized controlled clinical trial. J ESTHET RESTOR DENT 2019; 31:627-638. [PMID: 31631500 DOI: 10.1111/jerd.12534] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Revised: 08/08/2019] [Accepted: 09/10/2019] [Indexed: 11/28/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate the 2-year clinical performance of computer-aided design/computer-aided manufacturing (CAD/CAM) resin composite inlay restorations in comparison with direct resin composite restorations. MATERIALS AND METHODS In 44 patients, 120 class II (mesio-occlusal/disto-occlusal) cavities were randomly assigned into two groups; CAD/CAM resin composite inlay group (Lava Ultimate), direct resin composite group (Clearfil Majesty Posterior). Clinical evaluations were performed after 1 week, 6 months, 1 year, and 2 years according to the FDI criteria. The data were analyzed using Friedman's ANOVA and Mann-Whitney U tests (α = .05). RESULTS In 41 patients, 114 restorations were evaluated at the second year (recall rate 93.2%). All restorations were ideal or clinically acceptable. At the first year, considering all criteria, there were no statistically significant differences between the groups. However, there was a significant difference in terms of surface luster at second year, in favor of inlay restorations (P = .015). The marginal staining of resin composites increased after 2 years (P = .046), but there was no significant difference between the groups. CONCLUSIONS Except the surface luster, 2-year clinical performance of CAD/CAM resin composite inlay restorations was found similar to direct resin composite restorations according to FDI criteria CLINICAL SIGNIFICANCE: The clinical performance of CAD/CAM resin composite inlays was acceptable in class II cavities subsequent to 2-year evaluation.
Collapse
Affiliation(s)
- Ayse T Tunac
- Department of Restorative Dentistry, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| | - Esra U Celik
- Department of Restorative Dentistry, Faculty of Dentistry, Izmir Katip Celebi University, Izmir, Turkey
| | - Bilal Yasa
- Department of Restorative Dentistry, Faculty of Dentistry, Izmir Katip Celebi University, Izmir, Turkey
| |
Collapse
|
33
|
Eldafrawy M, Greimers L, Bekaert S, Gailly P, Lenaerts C, Nguyen JF, Sadoun M, Mainjot A. Silane influence on bonding to CAD-CAM composites: An interfacial fracture toughness study. Dent Mater 2019; 35:1279-1290. [DOI: 10.1016/j.dental.2019.05.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 05/21/2019] [Accepted: 05/22/2019] [Indexed: 11/28/2022]
|
34
|
Alamoush RA, Satterthwaite JD, Silikas N, Watts DC. Viscoelastic stability of pre-cured resin-composite CAD/CAM structures. Dent Mater 2019; 35:1166-1172. [PMID: 31146959 DOI: 10.1016/j.dental.2019.05.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 04/24/2019] [Accepted: 05/07/2019] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To study the effect of water storage (3 months) on the creep deformation and recovery of CAD/CAM composite materials to determine their viscoelastic stability. MATERIALS AND METHODS Five CAD/CAM composite blocks, with increasing filler loading, and one polymer-infiltrated ceramic network (PICN) were studied. Six specimens of each material were separated into two groups (n=3) according to their storage conditions (24 h dry storage at 23°C versus 3 months storage in 37°C distilled water). A constant static compressive stress of 20 MPa was applied on each specimen via a loading pin for 2 h followed by unloading and monitoring strain recovery for a further period of 2 h. The maximum creep-strain (%) and permanent set (%) were recorded. Data were analysed via two-way ANOVA followed by one-way ANOVA and Bonferroni post hoc tests (<0.05) for comparisons between the materials. Homogeneity of variance was calculated via Levene's statistics. RESULTS The maximum creep strain after 24 h dry ranged from 0.45% to 1.09% and increased after 3-month storage in distilled water to between 0.71% and 1.85%. The permanent set after 24 h dry storage ranged from 0.033% to 0.15% and increased after 3-month water storage to between 0.087% and 0.18%. The maximum creep strain also reduced with increasing filler loading. SIGNIFICANCE The PICN material exhibited superior dimensional stability to all of the pre-cured resin composite blocks in both storage conditions with deformation being predominantly elastic rather than viscoelastic. Notwithstanding, two of the resin-matrix composite blocks approached the PICN performance, when dry, but less so after water storage.
Collapse
Affiliation(s)
- Rasha A Alamoush
- Dentistry, School of Medical Sciences, The University of Manchester, Manchester, UK; Prosthodontic Department, School of Dentistry, University of Jordan, Amman, Jordan
| | | | - Nick Silikas
- Dentistry, School of Medical Sciences, The University of Manchester, Manchester, UK.
| | - D C Watts
- Dentistry, School of Medical Sciences, The University of Manchester, Manchester, UK
| |
Collapse
|
35
|
Electrochemical Deposition and Investigation of Poly-9,10-Phenanthrenequinone Layer. NANOMATERIALS 2019; 9:nano9050702. [PMID: 31064050 PMCID: PMC6566349 DOI: 10.3390/nano9050702] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 04/26/2019] [Accepted: 04/28/2019] [Indexed: 01/22/2023]
Abstract
In this research, a 9,10-phenanthrenequinone (PQ) was electrochemically polymerized on a graphite rod electrode using potential cycling. The electrode modified by poly-9,10-phenanthrenequinone (poly-PQ) was studied by means of cyclic voltammetry, electrochemical impedance spectroscopy, atomic force microscopy and scanning electron microscopy. The poly-PQ shows variations in growth pattern depending on the number of potential cycles for the initiation of polymerization. Formed poly-PQ layer demonstrates good electric conductivity, great degree of electrochemical capacitance and unique oxidation/reduction properties, which are suitable for broad technological applications, including applicability in biosensors, supercapacitors and in some other electrochemical systems.
Collapse
|
36
|
Papadopoulos C, Dionysopoulos D, Tolidis K, Kouros P, Koliniotou-Koumpia E, Tsitrou EA. Structural Integrity Evaluation of Large MOD Restorations Fabricated With a Bulk-Fill and a CAD/CAM Resin Composite Material. Oper Dent 2018; 44:312-321. [PMID: 30444690 DOI: 10.2341/18-013-l] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIMS To evaluate the effect of two composite restorative techniques (direct bulk fill vs indirect CAD/CAM) on the fracture resistance and mode of fracture of extended mesio-occlusal-distal (MOD) cavity preparations. METHODS Fifty-one sound human mandibular third molars were divided into three groups (n=17). Extended bucco-lingual MOD cavities were prepared. Teeth in group 1 were restored with a bulk-fill resin composite (Filtek Bulk-Fill Posterior Restorative), teeth in group 2 were restored with composite computer-aided design/computer-aided manufacturing (CAD/CAM) inlays (Lava Ultimate), and teeth in group 3 served as control and remained intact. All specimens were submitted to thermocycling, and a fracture resistance test was performed using a Universal testing machine (0.5 mm/min). Mode of fracture was classified into five types. One-way analysis of variance and the Duncan test were used to analyze the fracture load data at a significance level of α = 0.05. A chi-square test was used for the analysis of fracture mode between the restorative groups. RESULTS Statistical analysis showed significant differences in fracture resistance among the experimental groups. The teeth restored with the bulk-fill composite exhibited lower fracture resistance (1285.3±655.0 N) when compared to the teeth restored with the composite CAD/CAM inlays (1869.8±529.4 N) (p<0.05). Mode of fracture showed the same distribution between the restorative groups. CONCLUSIONS Although both types of restorations failed at loads larger than those found in the oral cavity, the CAD/CAM composite inlays increased the fracture resistance of teeth with large MOD cavities when compared to direct bulk-fill composite restorations. The majority of fracture types were intraorally repairable for both restorative techniques.
Collapse
|
37
|
Effect of the Composition of CAD/CAM Composite Blocks on Mechanical Properties. BIOMED RESEARCH INTERNATIONAL 2018; 2018:4893143. [PMID: 30426009 PMCID: PMC6218798 DOI: 10.1155/2018/4893143] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/25/2018] [Accepted: 10/09/2018] [Indexed: 11/18/2022]
Abstract
The aim of this study was to evaluate the effect of the composition of CAD/CAM blocks on their mechanical properties. Nine different CAD/CAM blocks, enamel and dentine, were tested. Sixteen samples of each material were separated for Vickers microhardness test (n=6, 5 readings per specimen), nanohardness test (n=6, 5 readings per specimen), filler weight (n=3), and SEM imaging (n=1). Data were statistically analysed using one-way ANOVA. Vita Mark II ceramic showed significantly higher values of hardness (in both nano- and microscale) and elastic modulus (6.83 GPa, 502 kg/mm2, and 47.7 GPa), respectively, than other materials. CAD/CAM composite blocks showed comparable values of hardness and elastic modulus to those of dentine but lower than those of enamel and ceramics. SEM images highlighted different filler-matrix microstructure of CAD/CAM composite blocks. It was concluded that (1) hardness and elastic moduli are positively correlated with ceramic filler percentage and microstructure and (2) CAD/CAM composite materials have comparable hardness and elastic moduli to tooth structure.
Collapse
|
38
|
Fatigue behavior and crack initiation of CAD/CAM resin composite molar crowns. Dent Mater 2018; 34:1578-1584. [DOI: 10.1016/j.dental.2018.07.002] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Revised: 06/12/2018] [Accepted: 07/09/2018] [Indexed: 11/21/2022]
|
39
|
Hussain B, Thieu MKL, Johnsen GF, Reseland JE, Haugen HJ. Can CAD/CAM resin blocks be considered as substitute for conventional resins? Dent Mater 2017; 33:1362-1370. [DOI: 10.1016/j.dental.2017.09.003] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2017] [Revised: 08/09/2017] [Accepted: 09/02/2017] [Indexed: 10/18/2022]
|
40
|
Yamaguchi S, Inoue S, Sakai T, Abe T, Kitagawa H, Imazato S. Multi-scale analysis of the effect of nano-filler particle diameter on the physical properties of CAD/CAM composite resin blocks. Comput Methods Biomech Biomed Engin 2017; 20:714-719. [PMID: 28387166 DOI: 10.1080/10255842.2017.1293664] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
The objective of this study was to assess the effect of silica nano-filler particle diameters in a computer-aided design/manufacturing (CAD/CAM) composite resin (CR) block on physical properties at the multi-scale in silico. CAD/CAM CR blocks were modeled, consisting of silica nano-filler particles (20, 40, 60, 80, and 100 nm) and matrix (Bis-GMA/TEGDMA), with filler volume contents of 55.161%. Calculation of Young's moduli and Poisson's ratios for the block at macro-scale were analyzed by homogenization. Macro-scale CAD/CAM CR blocks (3 × 3 × 3 mm) were modeled and compressive strengths were defined when the fracture loads exceeded 6075 N. MPS values of the nano-scale models were compared by localization analysis. As the filler size decreased, Young's moduli and compressive strength increased, while Poisson's ratios and MPS decreased. All parameters were significantly correlated with the diameters of the filler particles (Pearson's correlation test, r = -0.949, 0.943, -0.951, 0.976, p < 0.05). The in silico multi-scale model established in this study demonstrates that the Young's moduli, Poisson's ratios, and compressive strengths of CAD/CAM CR blocks can be enhanced by loading silica nanofiller particles of smaller diameter. CAD/CAM CR blocks by using smaller silica nano-filler particles have a potential to increase fracture resistance.
Collapse
Affiliation(s)
- Satoshi Yamaguchi
- a Department of Biomaterials Science , Osaka University Graduate School of Dentistry , Osaka , Japan
| | - Sayuri Inoue
- a Department of Biomaterials Science , Osaka University Graduate School of Dentistry , Osaka , Japan.,b Department of Orthodontics and Dentofacial Orthopedics , Osaka University Graduate School of Dentistry , Osaka , Japan
| | - Takahiko Sakai
- a Department of Biomaterials Science , Osaka University Graduate School of Dentistry , Osaka , Japan
| | - Tomohiro Abe
- a Department of Biomaterials Science , Osaka University Graduate School of Dentistry , Osaka , Japan
| | - Haruaki Kitagawa
- a Department of Biomaterials Science , Osaka University Graduate School of Dentistry , Osaka , Japan
| | - Satoshi Imazato
- a Department of Biomaterials Science , Osaka University Graduate School of Dentistry , Osaka , Japan
| |
Collapse
|
41
|
El Zhawi H, Kaizer MR, Chughtai A, Moraes RR, Zhang Y. Polymer infiltrated ceramic network structures for resistance to fatigue fracture and wear. Dent Mater 2016; 32:1352-1361. [PMID: 27585486 PMCID: PMC5075247 DOI: 10.1016/j.dental.2016.08.216] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2016] [Revised: 06/10/2016] [Accepted: 08/13/2016] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To investigate fatigue fracture resistance and wear behavior of a polymer infiltrated ceramic network (PICN) material (ENAMIC, Vita Zahnfabrik). METHODS Anatomically shaped ENAMIC monolithic crowns were milled using a CAD/CAM system. The crowns were cemented on aged dentin-like composite abutments (Z100, 3M ESPE) with resin-based cement (Vita DUO Cement, Vita). The specimens were subjected to 2 types of fatigue and wear tests: (1) accelerated sliding-contact mouth-motion step-stress fatigue test (n=24) in water; and (2) long-term sliding-contact mouth-motion fatigue/wear test using a clinically relevant load (P=200N, n=8) in water. Failure was designated as chip-off or bulk fracture. Optical and scanning electron microscopes were used to examine the occlusal surface and subsurface damage, as well as to reveal the material's microstructure. In addition, wear volume and depth were measured by X-ray micro-computed tomography. RESULTS For accelerated mouth-motion step-stress fatigue testing, 3 out of the 24 ENAMIC crowns fractured following cyclic loading up to 1700N. Minor occlusal damage and contact-induced cone cracks were observed in all surviving specimens, but no flexural radial cracks were seen. For long-term mouth-motion fatigue/wear testing under a 200N load in water, a small wear scar without significant cracks was observed in all 8 tested ENAMIC crowns. SIGNIFICANCE Monolithic CAD/CAM ENAMIC crowns showed superior resistance to sliding-contact fatigue fracture and wear.
Collapse
Affiliation(s)
- Haifa El Zhawi
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 First Avenue, New York, NY 10010, USA
| | - Marina R Kaizer
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 First Avenue, New York, NY 10010, USA; School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| | - Asima Chughtai
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 First Avenue, New York, NY 10010, USA
| | - Rafael R Moraes
- School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| | - Yu Zhang
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 First Avenue, New York, NY 10010, USA.
| |
Collapse
|
42
|
Kaizer MR, Almeida JR, Gonçalves APR, Zhang Y, Cava SS, Moraes RR. Silica Coating of Nonsilicate Nanoparticles for Resin-Based Composite Materials. J Dent Res 2016; 95:1394-1400. [PMID: 27470069 DOI: 10.1177/0022034516662022] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
This study was designed to develop and characterize a silica-coating method for crystalline nonsilicate ceramic nanoparticles (Al2O3, TiO2, and ZrO2). The hypothesis was that the coated nonsilicate nanoparticles would stably reinforce a polymeric matrix due to effective silanation. Silica coating was applied via a sol-gel method, with tetraethyl orthosilicate as a silica precursor, followed by heat treatment. The chemical and microstructural characteristics of the nanopowders were evaluated before and after silica coating through x-ray diffraction, BET (Brunauer-Emmett-Teller), energy-dispersive x-ray spectroscopy, field emission scanning electron microscopy, and transmission electron microscopy analyses. Coated and noncoated nanoparticles were silanated before preparation of hybrid composites, which contained glass microparticles in addition to the nanoparticles. The composites were mechanically tested in 4-point bending mode after aging (10,000 thermal cycles). Results of all chemical and microstructural analyses confirmed the successful obtaining of silica-coated nanoparticles. Two distinct aspects were observed depending on the type of nanoparticle tested: 1) formation of a silica shell on the surface of the particles and 2) nanoparticle clusters embedded into a silica matrix. The aged hybrid composites formulated with the coated nanoparticles showed improved flexural strength (10% to 30% higher) and work of fracture (35% to 40% higher) as compared with composites formulated with noncoated nanoparticles. The tested hypothesis was confirmed: silanated silica-coated nonsilicate nanoparticles yielded stable reinforcement of dimethacrylate polymeric matrix due to effective silanation. The silica-coating method presented here is a versatile and promising novel strategy for the use of crystalline nonsilicate ceramics as a reinforcing phase of polymeric composite biomaterials.
Collapse
Affiliation(s)
- M R Kaizer
- 1 Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Brazil
| | - J R Almeida
- 1 Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Brazil
| | - A P R Gonçalves
- 1 Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Brazil
| | - Y Zhang
- 2 College of Dentistry, New York University, New York, NY, USA
| | - S S Cava
- 3 School of Materials Engineering, Federal University of Pelotas, Pelotas, Brazil
| | - R R Moraes
- 1 Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Brazil
| |
Collapse
|
43
|
Duarte S, Sartori N, Phark JH. Ceramic-Reinforced Polymers: CAD/CAM Hybrid Restorative Materials. ACTA ACUST UNITED AC 2016. [DOI: 10.1007/s40496-016-0102-2] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
44
|
Tekçe N, Pala K, Demirci M, Tuncer S. Influence of different composite materials and cavity preparation designs on the fracture resistance of mesio-occluso-distal inlay restoration. Dent Mater J 2016; 35:523-31. [PMID: 27252011 DOI: 10.4012/dmj.2015-287] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The aim of the study to evaluate the fracture resistance of a computer-aided design/computer-aided manufacturing (CAD/CAM) and three indirect composite materials for three different mesio-occluso-distal (MOD) inlay cavity designs. A total of 120 mandibular third molar were divided into three groups: (G1) non-proximal box, (G2) 2-mm proximal box, and (G3) 4-mm proximal box. Each cavity design received four composite materials: Estenia, Epricord (Kuraray, Japan), Tescera (Bisco, USA), and Cerasmart CAD/CAM blocks (GC, USA). The specimens were subjected to a compressive load at a crosshead speed of 1 mm/min. The data was analyzed using the two-way analysis of variance and Bonferroni post hoc test (p<0.05). Estenia exhibited significantly higher fracture strength than Epricord and Cerasmart in G1. In G2 and G3, there was no significant difference among the four materials. Using a non-proximal box design for the cavity can improve the fracture resistance of the inlay restoration.
Collapse
Affiliation(s)
- Neslihan Tekçe
- Department of Restorative Dentistry, Faculty of Dentistry, Kocaeli University
| | | | | | | |
Collapse
|
45
|
Effects of High-Temperature-Pressure Polymerized Resin-Infiltrated Ceramic Networks on Oral Stem Cells. PLoS One 2016; 11:e0155450. [PMID: 27196425 PMCID: PMC4873200 DOI: 10.1371/journal.pone.0155450] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2015] [Accepted: 04/28/2016] [Indexed: 12/28/2022] Open
Abstract
OBJECTIVES The development of CAD-CAM techniques called for new materials suited to this technique and offering a safe and sustainable clinical implementation. The infiltration of resin in a ceramic network under high pressure and high temperature defines a new class of hybrid materials, namely polymer infiltrated ceramics network (PICN), for this purpose which requires to be evaluated biologically. We used oral stem cells (gingival and pulpal) as an in vitro experimental model. METHODS Four biomaterials were grinded, immersed in a culture medium and deposed on stem cells from dental pulp (DPSC) and gingiva (GSC): Enamic (VITA®), Experimental Hybrid Material (EHM), EHM with initiator (EHMi) and polymerized Z100™ composite material (3M®). After 7 days of incubation; viability, apoptosis, proliferation, cytoskeleton, inflammatory response and morphology were evaluated in vitro. RESULTS Proliferation was insignificantly delayed by all the tested materials. Significant cytotoxicity was observed in presence of resin based composites (MTT assay), however no detectable apoptosis and some dead cells were detected like in PICN materials. Cell morphology, major cytoskeleton and extracellular matrix components were not altered. An intimate contact appeared between the materials and cells. CLINICAL SIGNIFICANCE The three new tested biomaterials did not exhibit adverse effects on oral stem cells in our experimental conditions and may be an interesting alternative to ceramics or composite based CAD-CAM blocks.
Collapse
|
46
|
Mainjot A, Dupont N, Oudkerk J, Dewael T, Sadoun M. From Artisanal to CAD-CAM Blocks. J Dent Res 2016; 95:487-95. [DOI: 10.1177/0022034516634286] [Citation(s) in RCA: 170] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
Indirect composites have been undergoing an impressive evolution over the last few years. Specifically, recent developments in computer-aided design–computer-aided manufacturing (CAD-CAM) blocks have been associated with new polymerization modes, innovative microstructures, and different compositions. All these recent breakthroughs have introduced important gaps among the properties of the different materials. This critical state-of-the-art review analyzes the strengths and weaknesses of the different varieties of CAD-CAM composite materials, especially as compared with direct and artisanal indirect composites. Indeed, new polymerization modes used for CAD-CAM blocks—especially high temperature (HT) and, most of all, high temperature–high pressure (HT-HP)—are shown to significantly increase the degree of conversion in comparison with light-cured composites. Industrial processes also allow for the augmentation of the filler content and for the realization of more homogeneous structures with fewer flaws. In addition, due to their increased degree of conversion and their different monomer composition, some CAD-CAM blocks are more advantageous in terms of toxicity and monomer release. Finally, materials with a polymer-infiltrated ceramic network (PICN) microstructure exhibit higher flexural strength and a more favorable elasticity modulus than materials with a dispersed filler microstructure. Consequently, some high-performance composite CAD-CAM blocks—particularly experimental PICNs—can now rival glass-ceramics, such as lithium-disilicate glass-ceramics, for use as bonded partial restorations and crowns on natural teeth and implants. Being able to be manufactured in very low thicknesses, they offer the possibility of developing innovative minimally invasive treatment strategies, such as “no prep” treatment of worn dentition. Current issues are related to the study of bonding and wear properties of the different varieties of CAD-CAM composites. There is also a crucial need to conduct clinical studies. Last, manufacturers should provide more complete information regarding their product polymerization process, microstructure, and composition, which significantly influence CAD-CAM material properties.
Collapse
Affiliation(s)
- A.K. Mainjot
- Dental Biomaterials Research Unit (d-BRU) and Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège (ULg) and University of Liège Hospital (CHU), Liège, Belgium
| | - N.M. Dupont
- Dental Biomaterials Research Unit (d-BRU) and Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège (ULg) and University of Liège Hospital (CHU), Liège, Belgium
| | - J.C. Oudkerk
- Dental Biomaterials Research Unit (d-BRU) and Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège (ULg) and University of Liège Hospital (CHU), Liège, Belgium
| | - T.Y. Dewael
- Dental Biomaterials Research Unit (d-BRU) and Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège (ULg) and University of Liège Hospital (CHU), Liège, Belgium
| | | |
Collapse
|
47
|
Gilbert S, Keul C, Roos M, Edelhoff D, Stawarczyk B. Bonding between CAD/CAM resin and resin composite cements dependent on bonding agents: three different in vitro test methods. Clin Oral Investig 2015; 20:227-36. [DOI: 10.1007/s00784-015-1494-4] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2014] [Accepted: 05/04/2015] [Indexed: 11/30/2022]
|
48
|
Phan AC, Béhin P, Stoclet G, Dorin Ruse N, Nguyen JF, Sadoun M. Optimum pressure for the high-pressure polymerization of urethane dimethacrylate. Dent Mater 2015; 31:406-12. [DOI: 10.1016/j.dental.2015.01.010] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Revised: 12/20/2014] [Accepted: 01/12/2015] [Indexed: 11/28/2022]
|
49
|
Abstract
Advances in digital impression technology and manufacturing processes have led to a dramatic paradigm shift in dentistry and to the widespread use of computer-aided design/computer-aided manufacturing (CAD/CAM) in the fabrication of indirect dental restorations. Research and development in materials suitable for CAD/CAM applications are currently the most active field in dental materials. Two classes of materials are used in the production of CAD/CAM restorations: glass-ceramics/ceramics and resin composites. While glass-ceramics/ceramics have overall superior mechanical and esthetic properties, resin-composite materials may offer significant advantages related to their machinability and intra-oral reparability. This review summarizes recent developments in resin-composite materials for CAD/CAM applications, focusing on both commercial and experimental materials.
Collapse
Affiliation(s)
- N D Ruse
- Biomaterials, Faculty of Dentistry, University of British Columbia, 2199 Wesbrook Mall, Vancouver, BC V6T 1Z3, Canada
| | - M J Sadoun
- Unité de Recherches Biomatériaux Innovants et Interfaces (URB2I-EA4462), Faculté de chirurgie dentaire, Université Paris Descartes, Sorbonne Paris Cité, 1 rue Maurice Arnoux, 92120 Montrouge, France
| |
Collapse
|
50
|
Zhao Y, Lan J, Wang X, Deng X, Cai Q, Yang X. Synthesis of iodine-containing cyclophosphazenes for using as radiopacifiers in dental composite resin. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014; 43:432-8. [DOI: 10.1016/j.msec.2014.07.050] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2014] [Revised: 06/09/2014] [Accepted: 07/14/2014] [Indexed: 10/25/2022]
|