1
|
Novta E, Pantelić D, Blažić L, Tóth E, Cvejić Ž, Grujić D, Savić-Šević S, Lainović T. Impact of optical fiber-based photo-activation on dental composite polymerization. J Dent 2024; 145:104998. [PMID: 38636650 DOI: 10.1016/j.jdent.2024.104998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 04/04/2024] [Accepted: 04/16/2024] [Indexed: 04/20/2024] Open
Abstract
OBJECTIVES The study aimed to introduce a novel two-step optical fiber-based photo-activation of dental resin-based composites (RBCs) for reducing polymerization shrinkage stress (PSS). METHODS Proposed protocol design - in the first step, two flexible plastic optical fibers connected to a dental light curing unit (LCU), were used as light guides inserted into the filling to initiate low-irradiance polymerization from within; in the second step, fibers were extracted and remaining voids were filled with RBC, followed by conventional high-irradiance curing to finalize polymerization. Three bulk-fill RBCs were tested (Beautifil-Bulk Restorative, Filtek Bulk-fill Posterior, Tetric PowerFill) using tooth cavity models. Three non-invasive examination techniques were employed: Digital Holographic Interferometry, Infrared Thermography, and Raman spectroscopy for monitoring model deformation, RBC temperature change, and degree of conversion (DC), respectively. A control group (for each examined RBC) underwent conventional photo-activation. RESULTS The experimental protocol significantly reduced model deformation by 15 - 35 %, accompanied by an 18 - 54 % reduction in RBC temperature change, emphasizing the impact of thermal shrinkage on PSS. Real-time measurements of deformation and temperature provided indirect insights into reaction dynamics and illuminated potential mechanisms underlying PSS reduction. After a 24-hour dark-storage period, DC outcomes comparable to conventional curing were observed, affirming the clinical applicability of the method. CONCLUSIONS Protocol involving the use of two 1.5 mm fibers in the first step (300 mW/cm2 x 10 s), followed by a second conventional curing step (1000 mW/cm2 x 10 s), is recommended to achieve the desired PSS reduction, while maintaining adequate DC and ensuring efficient clinical application. CLINICAL SIGNIFICANCE Obtained PSS reduction offers promise in potentially improving the performance of composite restorations. Additionally, leveraging the flexibility of optical fibers improves light guide approach for restorations on posterior teeth. Meanwhile, implementation in clinical practice is easily achievable by coupling the fibers with commercial dental LCUs using the provided plastic adapter.
Collapse
Affiliation(s)
- Evgenije Novta
- University of Novi Sad, Faculty of Medicine, School of Dental Medicine, Hajduk Veljkova 12, Novi Sad, Serbia.
| | - Dejan Pantelić
- University of Belgrade, Institute of Physics, Pregrevica 118, Belgrade, Serbia
| | - Larisa Blažić
- University of Novi Sad, Faculty of Medicine, School of Dental Medicine, Hajduk Veljkova 12, Novi Sad, Serbia; Dental clinic of Vojvodina, Hajduk Veljkova 12, Novi Sad, Serbia
| | - Elvira Tóth
- University of Novi Sad, Faculty of Sciences, Department of Physics, Trg Dositeja Obradovića 3, Novi Sad, Serbia
| | - Željka Cvejić
- University of Novi Sad, Faculty of Sciences, Department of Physics, Trg Dositeja Obradovića 3, Novi Sad, Serbia
| | - Dušan Grujić
- University of Belgrade, Institute of Physics, Pregrevica 118, Belgrade, Serbia
| | | | - Tijana Lainović
- University of Novi Sad, Faculty of Medicine, School of Dental Medicine, Hajduk Veljkova 12, Novi Sad, Serbia
| |
Collapse
|
2
|
da Silva EM, Amaral CM, Jardim RN, Barbosa MP, Rabello TB. Influence of Specimen Dimension, Water Immersion Protocol, and Surface Roughness on Water Sorption and Solubility of Resin-Based Restorative Materials. MATERIALS (BASEL, SWITZERLAND) 2024; 17:984. [PMID: 38473457 DOI: 10.3390/ma17050984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 02/16/2024] [Accepted: 02/18/2024] [Indexed: 03/14/2024]
Abstract
The evaluation of water sorption and solubility is pivotal for the development of new resin-based restorative materials with the potential for clinical application. The purpose of the present study was to evaluate the influence of the specimen dimension, water immersion protocol, and surface roughness on the water sorption and solubility of three resin-based restorative materials. Disk-shaped specimens of 15 mm × 1 mm, 10 mm × 1 mm, and 6 mm × 1 mm were produced with a composite resin (Z100), a resin cement (RelyX ARC), and an adhesive system (Single Bond 2-SB2). The specimens were immersed in distilled water according to four protocols: ISO (all the specimens for each group were vertically immersed in 50 mL); IV-10 (the specimens were individually and vertically immersed in 10 mL); IH-10 (the specimens were individually and horizontally immersed in 10 mL); and IH-2 (the specimens were individually and horizontally immersed in 2 mL). The surface roughness (Sa and Sp) was evaluated using an atomic force microscope, and the degree of conversion was determined using FT-IR spectrometry. The specimen dimension and water immersion protocol had no effect on water sorption and solubility. For the three resin-based restorative materials, Sp was higher than Sa. The degree of conversion was not influenced by the specimen dimension. The variations in the specimen dimension and water immersion protocol compared to those determined by ISO 4049 did not prevent the comparison between the values of water sorption and solubility obtained for a given resin-based restorative material.
Collapse
Affiliation(s)
- Eduardo Moreira da Silva
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói 24040-110, Brazil
| | - Cristiane Mariote Amaral
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói 24040-110, Brazil
| | - Renata Nunes Jardim
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói 24040-110, Brazil
| | - Marianna Pires Barbosa
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói 24040-110, Brazil
| | - Tiago Braga Rabello
- Faculdade de Odontologia, Universidade Federal do Rio de Janeiro, Rio de Janeiro 21941-902, Brazil
| |
Collapse
|
3
|
Farah RI, Alblihed IA, Aljuoie AA, Alresheedi B. Light Polymerization through Glass-ceramics: Influence of Light-polymerizing Unit's Emitted Power and Restoration Parameters (Shade, Translucency, and Thickness) on Transmitted Radiant Power. Contemp Clin Dent 2024; 15:35-43. [PMID: 38707663 PMCID: PMC11068246 DOI: 10.4103/ccd.ccd_124_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 01/30/2024] [Accepted: 02/08/2024] [Indexed: 05/07/2024] Open
Abstract
Background This in vitro study assessed light transmission through ceramic discs varying in shade, translucency, and thickness using light-polymerizing units with different radiant power/flux (RP) outputs. Methods Disc-shaped specimens (0.5 mm, 1.0 mm, and 2.0 mm) were made from high and low-translucency glass-ceramic ingots (IPS e.max Press) in shades A1 and A4, totaling 60 discs. Two light-polymerizing units with different power outputs were used, and their emission spectra were verified. The transmitted RP values for each ceramic specimen were measured and irradiance and radiant energy influx were calculated. Differences between the light-polymerizing units and the influence of the three ceramic parameters were evaluated using an independent-samples t-test and three-way analysis of variance (ANOVA) tests (α = 0.05). Results A statistically significant difference was observed in the mean transmitted RP values between the two light-polymerizing units. Furthermore, the three-way ANOVA test showed a significant effect of shade, translucency, and thickness, as well as a significant interaction between each pair of variables and all three variables on the transmitted RP (P < 0.05). Conclusions Despite the significant attenuation in the transmitted RP, especially in ceramics with higher shade chromaticity and thickness and lower translucency, the calculated minimal irradiance values for both light-polymerizing units (their emitted power ≥ 500 mW) were greater than the minimum recommended irradiance threshold (100 mW/cm2). However, the exposure duration needs to be increased to provide the resin with sufficient radiant exposure for adequate polymerization.
Collapse
Affiliation(s)
- Ra’fat I. Farah
- Department of Prosthetic Dental Sciences, College of Dentistry, Qassim University, Al-Mulaydah, Qassim, Saudi Arabia
| | - Ibrahim A. Alblihed
- Medical City, College of Dentistry, Qassim University, Al-Mulaydah, Qassim, Saudi Arabia
| | - Alhareth A. Aljuoie
- Medical City, College of Dentistry, Qassim University, Al-Mulaydah, Qassim, Saudi Arabia
| | - Bandar Alresheedi
- Department of Prosthetic Dental Sciences, College of Dentistry, Qassim University, Al-Mulaydah, Qassim, Saudi Arabia
| |
Collapse
|
4
|
Macan M, Marošević A, Špiljak B, Šimunović L, Par M, Marovic D, Juric-Kacunic D, Tarle Z. Proposition of New Testing Procedure for the Mechanical Properties of Bulk-Fill Materials. MATERIALS (BASEL, SWITZERLAND) 2023; 16:4868. [PMID: 37445183 DOI: 10.3390/ma16134868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 07/05/2023] [Accepted: 07/05/2023] [Indexed: 07/15/2023]
Abstract
This study analysed flexural properties, microhardness, and the degree of conversion (DC) of five bulk-fill composites under clinically relevant conditions (4 mm thick specimens) in comparison to 2 mm specimens according to ISO 4049. Additionally, the effect of rapid polymerisation on 4 mm specimens was evaluated after accelerated aging. DC was measured using Fourier transform infrared spectrometry at 2 and 4 mm thick layers, while flexural properties and Vickers microhardness were tested using 16 × 2 × 2 mm or 16 × 2 × 4 mm specimens. Three polymerisation protocols were used: (I) "ISO": 2 mm thickness, 1000 mW/cm2, double-sided; (II) "10 s": 4 mm thickness, 1000 mW/cm2, one-sided; and (III) "3 s": 4 mm thickness, 2600 mW/cm2, one-sided. Mechanical properties were tested after 1 day, after 10,000 thermocycles, and after 10,000 thermocycles followed by a 7-day immersion in absolute ethanol. The "ISO" protocol produced a higher DC and microhardness of all materials. Elastic modulus was significantly higher for the "ISO" protocol compared to the 4 mm specimens. The differences in flexural strength for all polymerisation protocols were equalised after thermocycling and immersion in absolute ethanol. All tested materials met the ISO 4049 flexural strength requirement (80 MPa) for all polymerisation methods and all aging conditions. Rapid polymerisation achieved nearly optimal properties (ISO), except for elastic modulus, which was significantly reduced in 4 mm samples.
Collapse
Affiliation(s)
- Matea Macan
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Ana Marošević
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Bruno Špiljak
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Luka Šimunović
- Department of Orthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Matej Par
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Danijela Marovic
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | | | - Zrinka Tarle
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| |
Collapse
|
5
|
Lempel E, Szebeni D, Őri Z, Kiss T, Szalma J, Lovász BV, Kunsági-Máté S, Böddi K. The effect of high-irradiance rapid polymerization on degree of conversion, monomer elution, polymerization shrinkage and porosity of bulk-fill resin composites. Dent Mater 2023; 39:442-453. [PMID: 36918332 DOI: 10.1016/j.dental.2023.03.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 02/17/2023] [Accepted: 03/03/2023] [Indexed: 03/13/2023]
Abstract
OBJECTIVE The purpose was to compare the degree of conversion (DC), monomer elution (ME), polymerization shrinkage (PS) and porosity of two addition-fragmentation chain transfer (AFCT) modified resin-based composites (RBC) light-cured with rapid- (RP), turbo- (TP) or conventional polymerization (CP) settings. METHODS Cylindrical samples (6-mm wide, 4-mm thick) were prepared from Tetric PowerFill (TPF) and Filtek One Bulk (FOB). Four groups were established according to the polymerization settings: 3s-RP, 5s-TP, 10s-CP and 20s-CP. Samples in 1 mm thickness with 20s-CP settings served as controls. The DC at the top and bottom surfaces was measured with micro-Raman spectroscopy. ME was detected with high-performance liquid chromatography. PS and porosity were analyzed by micro-computed tomography. ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics were used to analyze the data (p < 0.05). RESULTS FOB showed higher DC values (61.5-77.5 %) at the top compared to TPF (43.5-67.8 %). At the bottom TPF samples achieved higher DCs (39.9-58.5 %) than FOB (18.21-66.18 %). Extending the curing time increased DC (except the top of FOB) and decreased ME. BisGMA release was the highest among the detected monomers from both RBCs. The amount was three-fold more from TPF. The factor Material and Exposure significantly influenced DC and ME. PS (1.8-2.5 %) did not differ among the groups and RBCs except for the lowest value of TPF cured with the 3s_RP setting (p = 0.03). FOB showed 4.5-fold lower porosity (p < 0.001). Significantly higher pore volume was detected after polymerization in 3s_RP (p < 0.001). SIGNIFICANCE High-irradiance rapid 3-s curing of AFCT modified RBCs resulted in inferior results for some important material properties. A longer exposure time is recommended in a clinical situation.
Collapse
Affiliation(s)
- Edina Lempel
- Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Tüzér Street 1, Pécs 7623, Hungary.
| | - Donát Szebeni
- Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Tüzér Street 1, Pécs 7623, Hungary
| | - Zsuzsanna Őri
- János Szentágothai Research Center, Ifjúság Street 12, Pécs 7624, Hungary; Department of General and Physical Chemistry, University of Pécs, Ifjúság Street 6, Pécs 7624, Hungary
| | - Tamás Kiss
- János Szentágothai Research Center, Ifjúság Street 12, Pécs 7624, Hungary
| | - József Szalma
- Department of Oral and Maxillofacial Surgery, University of Pécs Medical School, Tüzér Street 1, Pécs 7623, Hungary
| | - Bálint Viktor Lovász
- Department of Oral and Maxillofacial Surgery, University of Pécs Medical School, Tüzér Street 1, Pécs 7623, Hungary
| | - Sándor Kunsági-Máté
- János Szentágothai Research Center, Ifjúság Street 12, Pécs 7624, Hungary; Department of Organic and Medicinal Chemistry, University of Pécs, Faculty of Pharmacy, Honvéd Street 1, Pécs 7624, Hungary
| | - Katalin Böddi
- Department of Biochemistry and Medical Chemistry, University of Pécs Medical School, Szigeti Street 12, Pécs 7624, Hungary
| |
Collapse
|
6
|
Maucoski C, Price RB, Rocha MG, Roulet JF, Sullivan B. Ability of short exposures from laser and quad-wave curing lights to photo-cure bulk-fill resin-based composites. Dent Mater 2023; 39:275-292. [PMID: 36868892 DOI: 10.1016/j.dental.2023.01.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 01/10/2023] [Accepted: 01/25/2023] [Indexed: 03/05/2023]
Abstract
OBJECTIVE This study investigated the ability of a laser, and a 'quad-wave' LCU, to photo-cure paste and flowable bulk-fill resin-based composites (RBCs). METHODS Five LCUs and nine exposure conditions were used. The laser LCU (Monet) used for 1 s and 3 s, the quad-wave LCU (PinkWave) used for 3 s in the Boost and 20 s in the Standard modes, the the multi-peak LCU (Valo X) used for 5 s in the Xtra and 20 s in the Standard modes, were compared to the polywave PowerCure used in the 3 s mode and for 20 s in the Standard mode, and to the mono-peak SmartLite Pro used for 20 s. Two paste consistency bulk-fill RBCs: Filtek One Bulk Fill Shade A2 (3 M), Tetric PowerFill Shade IVA (Ivoclar Vivadent), and two flowable RBCs: Filtek Bulk Fill Flowable Shade A2 (3 M), Tetric PowerFlow Shade IVA (Ivoclar Vivadent) were photo-cured in 4-mm deep x 4-mm diameter metal molds. The light received by these specimens was measured using a spectrometer (Flame-T, Ocean Insight), and the radiant exposure delivered to the top surface of the RBCs was mapped. The immediate degree of conversion (DC) at the bottom, and the 24-hour Vickers Hardness (VH) at the top and bottom of the RBCs were measured and compared. RESULTS The irradiance received by the 4-mm diameter specimens ranged from 1035 mW/cm2 (SmartLite Pro) to 5303 mW/cm2 (Monet). The radiant exposures between 350 and 500 nm delivered to the top surface of the RBCs ranged from 5.3 J/cm2 (Monet in 1 s) to 26.4 J/cm2 (Valo X), although the PinkWave delivered 32.1 J/cm2 in 20 s 350 to 900 nm. All four RBCs achieved their maximum DC and VH values at the bottom when photo-cured for 20 s. The Monet used for 1 s and the PinkWave used for 3 s on the Boost setting delivered the lowest radiant exposures between 420 and 500 nm (5.3 J/cm2 and 3.5 J/cm2 respectively), and they produced the lowest DC and VH values. CONCLUSIONS Despite delivering a high irradiance, the short 1 or 3-s exposures delivered less energy to the RBC than 20-s exposures from LCUs that deliver> 1000 mW/cm2. There was an excellent linear correlation (r > 0.98) between the DC and the VH at the bottom. There was a logarithmic relationship between the DC and the radiant exposure (Pearson's r = 0.87-97) and between the VH and the radiant exposure (Pearson's r = 0.92-0.96) delivered in the 420-500 nm range.
Collapse
Affiliation(s)
- Cristiane Maucoski
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil; Department of Dental Clinical Sciences, Dalhousie University, Faculty of Dentistry, Halifax, Nova Scotia, Canada
| | - Richard Bengt Price
- Department of Dental Clinical Sciences, Dalhousie University, Faculty of Dentistry, Halifax, Nova Scotia, Canada.
| | - Mateus Garcia Rocha
- Department of Restorative Dental Science, Center of Dental Biomaterials College of Dentistry, University of Florida, Gainesville, FL, USA
| | - Jean-François Roulet
- Department of Restorative Dental Science, Center of Dental Biomaterials College of Dentistry, University of Florida, Gainesville, FL, USA
| | - Braden Sullivan
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil
| |
Collapse
|
7
|
Labrie D, Price RB, Sullivan B, Salazar AM, Gautam D, Stansbury JW, Ferracane JL. Effect of thickness on the degree of conversion of two bulk-fill and one conventional posterior resin-based composites at high irradiance and high temporal resolution. J Mech Behav Biomed Mater 2022; 136:105489. [PMID: 36206689 DOI: 10.1016/j.jmbbm.2022.105489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 09/22/2022] [Accepted: 09/24/2022] [Indexed: 11/30/2022]
Abstract
OBJECTIVES This study: 1) measures the effect of sample thickness and high irradiance on the depth-dependent time delay before photopolymerization reaction onset; 2) determines if exposure reciprocity exists; 3) measures the conversion rate at four irradiance levels; 4) determines the time, t0, at which the maximum DC rate is reached for two bulk-fill and one conventional posterior resin-based composites (RBCs). METHODS Tetric PowerFill IVA shade (Ivoclar Vivadent) and Aura bulk-fill ultra universal restorative (SDI), and one conventional posterior resin-based composite (RBC), Heliomolar A3 (Ivoclar Vivadent), that were either 0.2 mm, 2 mm, or 4 mm thick were photocured using a modified Bluephase G4 (Ivoclar Vivadent) light-curing unit (LCU) that delivered a single emission band (wavelength centered at 449 nm). The same radiant exposure of 24 J/cm2 was delivered at irradiances ranging from 0.5 to 3 W/cm2 by adjusting the exposure time. PowerFill was also photocured for 3 s or 6 s using a Bluephase PowerCure LCU (Ivoclar Vivadent) on the 3 s mode setting. The degree of conversion (DC) was measured in real-time at a high temporal resolution at 30 °C using Attenuated Total Reflection (ATR) FTIR spectroscopy with a sampling rate of 13 DC data points per second. The DC data were analyzed using a phenomenological autocatalytic model. The RBC viscosity was measured at 21 °C and 30 °C. Light transmission through the RBC samples at 22 °C was monitored with time to calculate the extinction coefficients of the RBCs. RESULTS The time delay before photopolymerization started increased as the RBC thickness increased and the irradiance decreased. An autocatalytic model described the DC data. The time t0 was less than 77 ms for the 0.2 mm thick samples of PowerFill irradiated using the highest irradiance of 3 W/cm2. Among the three RBCs for each sample thickness and irradiance level, the PowerFill had the smallest time t0. There was a time delay of 0.59 s and 1.25 s before the DC started to increase at the bottom of 4 mm thick samples for the PowerFill and Aura, respectively, when an irradiance of 1 W/cm2 was delivered. The time delay increased to 3.65 s for the Aura when an irradiance of 0.5 W/cm2 was delivered. The extinction coefficients near 449 nm were 0.78 mm-1, 0.76 mm-1, and 1.55 mm-1 during the first 2 s after the start of photocuring of PowerFill, Aura, and Heliomolar, respectively. Only PowerFill followed exposure reciprocity. At T = 30 °C, the viscosity was 3400, 17000, and 5200 Paˑs for PowerFill, Aura, and Heliomolar, respectively. SIGNIFICANCE The time delay between when photopolymerization starts at the top and bottom of 2- or 4-mm thick RBC restorations may affect the structural integrity of the bond between the tooth and the bottom of the restoration. Only PowerFill followed exposure reciprocity between irradiance levels of 0.5 to 3 W/cm2. Exposure reciprocity did not occur for Aura or Heliomolar, neither of which are optimized for short light exposure or high irradiance conditions.
Collapse
Affiliation(s)
- Daniel Labrie
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada.
| | - Richard B Price
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada
| | - Braden Sullivan
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada
| | - Austyn M Salazar
- Department of Chemical and Biological Engineering, University of Colorado, Boulder, CO, 80309-0596, United States
| | - Dixa Gautam
- Department of Chemical and Biological Engineering, University of Colorado, Boulder, CO, 80309-0596, United States
| | - Jeffrey W Stansbury
- Department of Chemical and Biological Engineering, University of Colorado, Boulder, CO, 80309-0596, United States; Department of Craniofacial Biology, School of Dental Medicine, University of Colorado, Anschutz Medical Campus, Aurora, CO, 80045, United States
| | - Jack L Ferracane
- Department of Restorative Dentistry, Oregon Health & Science University, Portland, OR, United States
| |
Collapse
|
8
|
Maximov J, Dikova T, Duncheva G, Georgiev G. Influence of Factors in the Photopolymerization Process on Dental Composites Microhardness. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6459. [PMID: 36143771 PMCID: PMC9502933 DOI: 10.3390/ma15186459] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 09/12/2022] [Accepted: 09/13/2022] [Indexed: 06/16/2023]
Abstract
The aim of the present paper is to investigate the influence of factors in photopolymerization process that govern microhardness of three types of dental composites-universal (UC), bulk-fill (BC), and flowable (FC). Cylindrical specimens with different thicknesses are made and light cured. The significance of light intensity, irradiation time, and layer thickness on Vickers microhardness is evaluated by experimental design, analysis of variance, and regression analysis. It is found that the main factor influencing the microhardness on the top surface of the three composites is light intensity. The second factor is layer thickness for the UC and FC, while for BC, it is curing time. The third factor is curing time for the first two composites and layer thickness for bulk-fill. The significance of factors' influence on the microhardness of the bottom surface is the same for the UC and FC, but different for BC. The main factor for the first two composites is layer thickness, followed by curing time and light intensity. For bulk-fill, curing time is main factor, light intensity is second, and layer thickness is last. Different significance of factors influencing the microhardness on top and bottom surfaces of investigated composites is revealed for the first time in the present study.
Collapse
Affiliation(s)
- Jordan Maximov
- Faculty of Mechanical Engineering, Technical University of Gabrovo, 4 Hadji Dimitar Str., 5300 Gabrovo, Bulgaria
| | - Tsanka Dikova
- Faculty of Dental Medicine, Medical University of Varna, 84 Tsar Osvoboditel Blvd., 9000 Varna, Bulgaria
| | - Galya Duncheva
- Faculty of Mechanical Engineering, Technical University of Gabrovo, 4 Hadji Dimitar Str., 5300 Gabrovo, Bulgaria
| | - Georgi Georgiev
- Faculty of Dental Medicine, Medical University of Varna, 84 Tsar Osvoboditel Blvd., 9000 Varna, Bulgaria
| |
Collapse
|
9
|
Grazioli G, Cuevas-Suarez CE, Mederos M, DE Leon E, Garcia A, Zamarripa-Calderón E, Piva E. Evaluation of irradiance and radiant exposure on the polymerization and mechanical properties of a resin composite. Braz Oral Res 2022; 36:e082. [PMID: 35703707 DOI: 10.1590/1807-3107bor-2022.vol36.0082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Accepted: 03/07/2022] [Indexed: 11/21/2022] Open
Abstract
The objective of the present study was to evaluate the effect of irradiance and radiant exposure on the chemical-mechanical properties of a resin composite. A micro-hybrid resin composite (Clearfil AP-X, Kuraray) was investigated under two different irradiances: low (300 mW/cm2) and high (800 mW/cm2) and radiant exposures: 8 and 16 J/cm2. Four groups, named Low 8 J/cm2, High 8 J/cm2, Low 16 J/cm2, and High 16 J/cm2 were tested, and their flexural strengths, elastic moduli, depths of cure, and degrees of conversion were evaluated. Data were analyzed using two-way ANOVA and Tukey's test. A multiple linear regression model was used to correlate the irradiance and radiant exposure with dependent variables (α = 0.05). Irradiance and radiant exposure were found statistically significant for all dependent variables. The interaction between the factors was statistically significant only for the degree of conversion and elastic modulus. Group Low 16 J/cm2 exhibited a significantly superior performance in all the evaluated properties. Barring the degree of conversion, no significant differences were observed among the properties evaluated between the Low 8 J/cm2 and High 8 J/cm2 groups. The adjusted R2 values were high for the depth of cure and degree of conversion (0.58 and 0.96, respectively). Both irradiance and radiant exposure parameters play an important role in establishing the final properties of a micro-hybrid resin composite. Irradiance has a greater influence under higher radiant exposures.
Collapse
Affiliation(s)
- Guillermo Grazioli
- Universidad de la República , School of Dentistry , Department of Dental Materials , Montevideo , Uruguay
| | - Carlos Enrique Cuevas-Suarez
- Autonomous University of Hidalgo State , Academic Area of Dentistry , Dental Materials Laboratory , San Agustín Tlaxiaca , Hgo , Mexico
| | - Matías Mederos
- Universidad de la República , School of Dentistry , Department of Dental Materials , Montevideo , Uruguay
| | - Elisa DE Leon
- Universidad de la República , School of Dentistry , Department of Dental Materials , Montevideo , Uruguay
| | - Andrés Garcia
- Universidad de la República , School of Dentistry , Department of Dental Materials , Montevideo , Uruguay
| | - Eliezer Zamarripa-Calderón
- Autonomous University of Hidalgo State , Academic Area of Dentistry , Dental Materials Laboratory , San Agustín Tlaxiaca , Hgo , Mexico
| | - Evandro Piva
- Universidade Federal de Pelotas - UFPel, School of Dentistry , Department of Restorative Dentistry , Pelotas , RS , Brazil
| |
Collapse
|
10
|
Tichy A, Bradna P. Applicability of Exposure Reciprocity Law for Fast Polymerization of Restorative Composites Containing Various Photoinitiating Systems. Oper Dent 2021; 46:406-418. [PMID: 34478559 DOI: 10.2341/20-112-l] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/25/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVES The exposure reciprocity law (ERL) has been used to calculate the optimal irradiation time of dental composites. This study examined the applicability of ERL for fast polymerization of restorative composites containing various photoinitiating systems using a high-power multi-peak light-emitting diode (LED) lamp. METHODS Three commercial composites differing in photoinitiating systems were tested: Filtek Ultimate Universal Restorative (FU) with a camphorquinone-amine (CQ-A) photoinitiating system, Tetric EvoCeram (TEC) with CQ-A and (2,4,6-trimethylbenzoyl)phosphine oxide (TPO), and Estelite Σ Quick (ESQ) with CQ and a radical amplified photopolymerization (RAP) initiator. Specimens 2-mm thick were polymerized using a high-power multipeak LED lamp (Valo) at 3 pairs of radiant exposures (referred to as low, moderate, and high) ranging from 15.8-26.7 J/cm2. They were achieved by different combinations of irradiation time (5-20 seconds) and irradiance (1300-2980 mW/cm2) as determined with a calibrated spectrometer. Knoop microhardness was measured 1, 24, and 168 hours after polymerization on specimen top (irradiated) and bottom surfaces to characterize the degree of polymerization. The results were statistically analyzed using a three-way analysis of variance and Tukey's post hoc tests, α = 0.05. RESULTS Microhardness increased with radiant exposure and except for ESQ, top-surface microhardness was significantly higher than that on bottom surfaces. Combinations of high irradiance and short irradiation time significantly increased the top-surface microhardness of TEC at low and moderate radiant exposures, and the bottom-surface microhardness of FU at a low radiant exposure. In contrast, the microhardness of ESQ on both surfaces at high radiant exposure increased significantly when low irradiance and long irradiation time were used. With all tested composites, bottom-surface microhardness obtained at low radiant exposure was below 80% of the maximum top-surface microhardness, indicating insufficient polymerization. CONCLUSION Combinations of irradiance and irradiation time had a significant effect on microhardness, which was affected by photoinitiators and the optical properties of composites as well as spectral characteristics of the polymerization lamp. Therefore, ERL cannot be universally applied for the calculation of optimal composite irradiation time. Despite high irradiance, fast polymerization led to insufficient bottom-surface microhardness, suggesting the necessity to also characterize the degree of polymerization on the bottom surfaces of composite increments when assessing the validity of ERL.
Collapse
|
11
|
Shrinkage Stress and Temperature Variation in Resin Composites Cured via Different Photoactivation Methods: Insights for Standardisation of the Photopolymerisation. Polymers (Basel) 2021; 13:polym13132065. [PMID: 34201846 PMCID: PMC8272171 DOI: 10.3390/polym13132065] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 05/12/2021] [Accepted: 05/13/2021] [Indexed: 11/16/2022] Open
Abstract
The literature has shown that there is no consensus regarding the best resin composite photoactivation protocol. This study evaluated the efficiency of the conventional, soft-start, pulse-delay and exponential protocols for photoactivation of resin composites in reducing the shrinkage stress and temperature variation during the photopolymerisation. The photoactivation processes were performed using a photocuring unit and a smartphone app developed to control the irradiance according each photoactivation protocol. These photoactivation methods were evaluated applying photoactivation energies recommended by the resins manufactures. Three brands of resin composites were analysed: Z-250, Charisma and Ultrafill. The cure effectiveness was evaluated through depth of cure experiments. All results were statistically evaluated using one-way and multi-factor analysis of variance (ANOVA). The use of exponential and pulse-delay methods resulted in a significant reduction of the shrinkage stress for all evaluated resins; however, the pulse-delay method required too long a photoactivation time. The increases on the temperature were lower when the exponential photoactivation was applied; however, the temperature variation for all photoactivation protocols was not enough to cause damage in the restoration area. The evaluation of the depth of cure showed that all photoactivation protocols resulted in cured resins with equivalent hardness, indicating that the choice of an alternative photoactivation protocol did not harm the polymerisation. In this way, the results showed the exponential protocol as the best photoactivation technique for practical applications.
Collapse
|
12
|
Li Q, Lin HL, Zheng M, Ozcan M, Yu H. Minimum Radiant Exposure and Irradiance for Triggering Adequate Polymerization of a Photo-Polymerized Resin Cement. MATERIALS 2021; 14:ma14092341. [PMID: 33946389 PMCID: PMC8124640 DOI: 10.3390/ma14092341] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 04/23/2021] [Accepted: 04/26/2021] [Indexed: 12/02/2022]
Abstract
This study aimed to establish the minimum radiant exposure and irradiance to trigger an adequate polymerization of a photo-polymerized resin cement. In total, 220 disc-shaped specimens (diameter of 10 mm and thickness of 0.1 mm) were fabricated using a photo-polymerized resin cement (Variolink N-transparent, Ivoclar Vivadent). To investigate the minimum radiant exposure, the specimens were polymerized with radiant exposures of 1, 2, 3, 4, 5, 6, and 18 J/cm2 (n = 20). During polymerization, the irradiance was maintained at 200 mW/cm2. To investigate the minimum irradiance, the specimens were polymerized with irradiances of 50, 100, 150, and 200 mW/cm2 (n = 20). During polymerization, the radiant exposure was maintained at the previously determined minimum radiant exposure. The Vickers microhardness (HV) and degree of conversion (DC) of the carbon double bond of the specimens were measured to determine the degree of polymerization of the specimens. The results were analyzed using one-way analysis of variance (ANOVA) and Tukey’s test (p < 0.05). In the investigation of the minimum radiant exposure, the HV and DC of the specimens polymerized with a radiant exposure from 1 to 5 J/cm2 were significantly lower than those with 18 J/cm2 (all p < 0.05). However, no significant difference in HV and DC was found between the specimens polymerized with 6 J/cm2 and 18 J/cm2 (p > 0.05). In the investigation of the minimum irradiance, the specimens polymerized with an irradiance of 50 mW/cm2 had significantly lower HV and DC than the specimens polymerized with an irradiance of 200 mW/cm2 (p < 0.05). However, no significant difference in the HV and DC was found among the specimens cured with irradiances of 100, 150, and 200 mW/cm2 (p > 0.05). In conclusion, the minimum radiant exposure and irradiance to trigger an adequate polymerization of the light-cured resin cement were 6 J/cm2 and 100 mW/cm2, respectively.
Collapse
Affiliation(s)
- Qi Li
- Fujian Key Laboratory of Oral Diseases, Fujian Provincial Engineering Research Center of Oral Biomaterial, Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou 350000, China; (Q.L.); (H.-L.L.)
- Fujian Provincial Governmental Hospital, Fuzhou 350000, China
| | - Hong-Lei Lin
- Fujian Key Laboratory of Oral Diseases, Fujian Provincial Engineering Research Center of Oral Biomaterial, Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou 350000, China; (Q.L.); (H.-L.L.)
| | - Ming Zheng
- Fujian Key Laboratory of Oral Diseases, Fujian Provincial Engineering Research Center of Oral Biomaterial, Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou 350000, China; (Q.L.); (H.-L.L.)
- Correspondence: (M.Z.); or (H.Y.)
| | - Mutlu Ozcan
- Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, 8006 Zurich, Switzerland;
| | - Hao Yu
- Fujian Key Laboratory of Oral Diseases, Fujian Provincial Engineering Research Center of Oral Biomaterial, Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou 350000, China; (Q.L.); (H.-L.L.)
- Correspondence: (M.Z.); or (H.Y.)
| |
Collapse
|
13
|
Yılmaz B, Bakkal M, Zengin Kurt B. Structural and mechanical analysis of three orthodontic adhesive composites cured with different light units. J Appl Biomater Funct Mater 2021; 18:2280800020901716. [PMID: 32242502 DOI: 10.1177/2280800020901716] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVE To evaluate the effects of three different curing units on the physical and mechanical features of three different orthodontic adhesive resin materials. MATERIAL AND METHODS 45 specimens (5 mm in diameter, and 2 mm in thickness) of each of the three different adhesive composite resin materials (Transbond XT, Grēngloo™ Adhesive and Light Bond Paste) were cured with three different light units (a polywave third generation (Valo), a monowave (DemiUltra), and a second-generation LED (Optima 10)). To quantify degree of conversion (DC), the Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy was used in transmission mode (ALPHA FT-IR Spectrometer, Bruker Optics, Germany). Vickers hardness value was recorded under constant load 100 g for 10 s with a microhardness tester (HMV M-1, Shimadzu Corp., Kyoto, Japan). The data were statistically analyzed using Kruskal-Wallis and chi-square tests. The level of significance was considered p < 0.05. RESULTS The highest DC values were obtained as a result of curing with Optima 10. This rate was followed by Demi Ultra and Valo, respectively. Transbond XT samples showed a lower level of conversion than the samples of Light Bond Paste and Grēngloo™ Adhesive. The top surfaces of each material showed higher hardness values than the bottom surfaces (p < 0.05). The Light Bond Paste showed the highest hardness values both on the top and bottom surfaces among the three materials, followed by Grēngloo™ Adhesive. While the hardness values of the top surfaces of the samples cured with Demi Ultra and Valo light units were similar, higher hardness values are recorded with Valo on the bottom surfaces (Valo; 85.200/75.200 (top/bottom) versus Demi Ultra; 86.100/66.000 (top/bottom)). CONCLUSIONS The different DC and the surface hardness properties were recorded for the resin as orthodontic adhesives depending on different light units. Shorter radiation time caused lower DC and surface hardness values.
Collapse
Affiliation(s)
- Berza Yılmaz
- Department of Orthodontics, Bezmialem Vakif University, Istanbul, Turkey
| | - Meltem Bakkal
- Department of Pediatric Dentistry, Bezmialem Vakif University, Istanbul, Turkey
| | - Belma Zengin Kurt
- Department of Pharmaceutical Biotechnology, Bezmialem Vakif University, Istanbul, Turkey
| |
Collapse
|
14
|
Degree of conversion and in vitro temperature rise of pulp chamber during polymerization of flowable and sculptable conventional, bulk-fill and short-fibre reinforced resin composites. Dent Mater 2021; 37:983-997. [PMID: 33714623 DOI: 10.1016/j.dental.2021.02.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 02/03/2021] [Accepted: 02/24/2021] [Indexed: 11/24/2022]
Abstract
OBJECTIVE Determine the degree of conversion (DC) and in vitro pulpal temperature (PT) rise of low-viscosity (LV) and high-viscosity (HV) conventional resin-based composites (RBC), bulk-fill and short-fibre reinforced composites (SFRC). METHODS The occlusal surface of a mandibular molar was removed to obtain dentine thickness of 2 mm above the roof of the pulp chamber. LV and HV conventional (2 mm), bulk-fill RBCs (2-4 mm) and SFRCs (2-4 mm) were applied in a mold (6 mm inner diameter) placed on the occlusal surface. PT changes during the photo-polymerization were recorded with a thermocouple positioned in the pulp chamber. The DC at the top and bottom of the samples was measured with micro-Raman spectroscopy. ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics were used to analyze the data (p < 0.05). RESULTS The PT changes ranged between 5.5-11.2 °C. All LV and 4 mm RBCs exhibited higher temperature changes. Higher DC were measured at the top (63-76%) of the samples as compared to the bottom (52-72.6%) in the 2 mm HV conventional and bulk-fill RBCs and in each 4 mm LV and HV materials. The SFRCs showed higher temperature changes and DC% as compared to the other investigated RBCs. The temperature and DC were influenced by the composition of the material followed by the thickness. SIGNIFICANCE Exothermic temperature rise and DC are mainly material dependent. Higher DC values are associated with a significant increase in PT. LV RBCs, 4 mm bulk-fills and SFRCs exhibited higher PTs. Bulk-fills and SFRCs applied in 4 mm showed lower DCs at the bottom.
Collapse
|
15
|
Marovic D, Par M, Crnadak A, Sekelja A, Negovetic Mandic V, Gamulin O, Rakić M, Tarle Z. Rapid 3 s Curing: What Happens in Deep Layers of New Bulk-Fill Composites? MATERIALS 2021; 14:ma14030515. [PMID: 33494495 PMCID: PMC7866022 DOI: 10.3390/ma14030515] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/08/2021] [Accepted: 01/19/2021] [Indexed: 12/13/2022]
Abstract
This study assessed the influence of rapid 3 s light curing on the new generation of bulk-fill resin composites under the simulated aging challenge and depths up to 4 mm. Four bulk-fill materials were tested: two materials designed for rapid curing (Tetric PowerFill—PFILL; Tetric PowerFlow—PFLW) and two regular materials (Filtek One Bulk Fill Restorative—FIL; SDR Plus Bulk Fill Flowable—SDR). Three-point bending (n = 10) was used to measure flexural strength (FS) and flexural modulus (FM). In the 3 s group, two 2 mm thick specimens were stacked to obtain 4 mm thickness, while 2 mm-thick specimens were used for ISO group. Specimens were aged for 1, 30, or 30 + 3 days in ethanol. The degree of conversion (DC) up to 4 mm was measured by Raman spectroscopy. There was no difference between curing protocols in FS after 1 day for all materials except PFLW. FM was higher for all materials for ISO curing protocol. Mechanical properties deteriorated by increasing depth (2–4 mm) and aging. ISO curing induced higher DC for PFLW and FIL, while 3 s curing was sufficient for PFILL and SDR. The 3 s curing negatively affected FM of all tested materials, whereas its influence on FS and DC was highly material-specific.
Collapse
Affiliation(s)
- Danijela Marovic
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Zagreb 10000, Croatia; (D.M.); (A.C.); (A.S.); (V.N.M.); (Z.T.)
| | - Matej Par
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Zagreb 10000, Croatia; (D.M.); (A.C.); (A.S.); (V.N.M.); (Z.T.)
- Correspondence:
| | - Ana Crnadak
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Zagreb 10000, Croatia; (D.M.); (A.C.); (A.S.); (V.N.M.); (Z.T.)
| | - Andjelina Sekelja
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Zagreb 10000, Croatia; (D.M.); (A.C.); (A.S.); (V.N.M.); (Z.T.)
| | - Visnja Negovetic Mandic
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Zagreb 10000, Croatia; (D.M.); (A.C.); (A.S.); (V.N.M.); (Z.T.)
| | - Ozren Gamulin
- Institute for Physics and Biophysics, School of Medicine, University of Zagreb, Zagreb 10000, Croatia;
| | - Mario Rakić
- Institute of Physics, Zagreb 10000, Croatia;
| | - Zrinka Tarle
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Zagreb 10000, Croatia; (D.M.); (A.C.); (A.S.); (V.N.M.); (Z.T.)
| |
Collapse
|
16
|
Slack WE, Yancey EM, Lien W, Sheridan R, Phoenix R, Vandewalle K. Effect of high-irradiance light curing on exposure times and pulpal temperature of adequately polymerized composite. Dent Mater J 2020; 39:976-983. [PMID: 32727961 DOI: 10.4012/dmj.2019-236] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study investigated the effect of high-irradiance light-curing on exposure time and pulpal temperature of adequately-cured composite. Composite placed in a molar preparation was cured using high-irradiance light-curing units (Flashmax P3, Valo, S.P.E.C. 3 LED, Cybird XD) and tested for hardness occlusal-gingivally. The first group had exposure times set according to manufacturer settings (recommended), second group to yield 80% of maximum hardness at the 2 mm depth (experimental), and third group was set at 20 s (extended). Exposure time necessary to adequately polymerize the composite at 2 mm depth was 9 s for the Cybird XD and Valo and 12 s for S.P.E.C. 3 LED and Flashmax P3. None of the high-irradiance light-curing units adequately polymerized the composite at the manufacturer-recommended minimum-exposure times of 1-3 s. Exposure times necessary to adequately polymerize composite at 2 mm resulted in a maximum pulpal-temperature increase well below the temperature associated with possible pulpal necrosis.
Collapse
Affiliation(s)
| | | | - Wen Lien
- USAF Dental Research and Consultation Service
| | | | - Rodney Phoenix
- Postgraduate Dental College, Uniformed Services University of the Health Sciences
| | - Kraig Vandewalle
- Advanced Education in General Dentistry Residency.,Uniformed Services University of the Health Sciences
| |
Collapse
|
17
|
Hayashi J, Tagami J, Chan D, Sadr A. New bulk-fill composite system with high irradiance light polymerization: Integrity and degree of conversion. Dent Mater 2020; 36:1615-1623. [PMID: 33168226 DOI: 10.1016/j.dental.2020.10.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 09/05/2020] [Accepted: 10/06/2020] [Indexed: 01/05/2023]
Abstract
OBJECTIVE The study used optical coherence tomography (OCT) and micro Raman microscopy (mRM) to investigate internal defect (ID) and degree of conversion (DC) of two bulk-fill composite systems with high-irradiance or conventional light polymerization settings. METHODS The ID and DC of the new bulk-fill composites; Tetric PowerFill (PwrPst) and Tetric PowerFlow (PwrFlw) were compared with the predecessor bulk-fill composites; Tetric EvoCeram Bulkfill (EvoPst) and Tetric EvoFlow Bulkfill (EvoFlw), using LED light curing unit in two settings; normal (LED-Nrm: 1000 mW/cm2, 10-s) or PowerCure (LED-Pwr: 3000 mW/cm2, 3-s). ID formation was observed in bonded cylindrical composite cavities (4-mm depth, 3-mm diameter) using Yoshida Dental OCT. From the vertically projected 2D image, ID area percentage (ID-A%) was calculated. DC at the top and bottom and bottom/top DC ratio (DC-R%) of 4-mm thick discs was calculated using mRM. All data were statistically analyzed at significance level of α = 0.05. RESULTS Flowable composites in LED-Pwr showed smaller ID frequencies than other groups (PwrFlw: 0/8, EvoFlw: 2/8) (p < 0.05). Composite type significantly affected ID-A%, DC and DC-R% (p < 0.001), while light settings significantly affected ID-A% but not DC and DC-R% (p > 0.05). In both light settings, EvoPst showed the lowest DC-R% (<80%). SIGNIFICANCE Internal defect and degree of conversion of bulk-fill composites were affected by their composition and light settings. There was a tendency for less defects and better polymerization for the flowable bulk-fills. The new flowable bulk-fill composite with 3-seconds high irradiance light curing showed no defect formation.
Collapse
Affiliation(s)
- Juri Hayashi
- Department of Restorative Dentistry, Biomimetics Biomaterials Biophotonics Biomechanics & Technology Laboratory, School of Dentistry, University of Washington, 1959 NE Pacific Street, Seattle, WA 98195-7456, USA; Cariology and Operative Dentistry, Department of Restorative Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Junji Tagami
- Cariology and Operative Dentistry, Department of Restorative Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Daniel Chan
- Department of Restorative Dentistry, Biomimetics Biomaterials Biophotonics Biomechanics & Technology Laboratory, School of Dentistry, University of Washington, 1959 NE Pacific Street, Seattle, WA 98195-7456, USA
| | - Alireza Sadr
- Department of Restorative Dentistry, Biomimetics Biomaterials Biophotonics Biomechanics & Technology Laboratory, School of Dentistry, University of Washington, 1959 NE Pacific Street, Seattle, WA 98195-7456, USA.
| |
Collapse
|
18
|
Al-Zain AO, Platt JA. Effect of light-curing distance and curing time on composite microflexural strength. Dent Mater J 2020; 40:202-208. [PMID: 32999258 DOI: 10.4012/dmj.2020-002] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study investigated the influence of curing distance on µ-flexural strength (µ-FS) of a nano-hybrid composite, cured using the manufacturer-recommended curing time (MCT), compared to a consistent radiant exposure (CRE) using three different light-curing units (LCUs). Beams (6×2×1 mm) were cured using the MCT or CRE with a quartz-tungsten-halogen (QTH); a single-emission-peak light-emitting-diode (SLED), or a multiple-emission-peak light-emitting-diode (MLED) LCU. Specimens were cured at 0-, 2- or 8-mm distances (n=10) and the bottom irradiance and CRE were measured using a Managing Accurate Resin Curing-Resin Calibrator spectrometer. µ-FS testing was performed, and data analyzed using two-way ANOVA and Tukey multiple comparison tests (α=0.05). Mean bottom irradiance was (25.4-99.7 mW/cm2) and CRE (0.31-1.11 J/cm2). µ-FS was 422.1-516.6 MPa (MCT) and 440.4-490.4 MPa (CRE). Comparing CRE to MCT showed that µ-FS significantly decreased using the CRE at 2-mm (QTH) or the MCT at 2- and 8-mm (SLED). µ-FS may be significantly impacted by the curing protocol.
Collapse
Affiliation(s)
- Afnan O Al-Zain
- Operative and Esthetic Dentistry Division, Restorative Dentistry Department, Faculty of Dentistry, King Abdulaziz University
| | - Jeffrey A Platt
- Department of Biomedical Sciences and Comprehensive Care, Indiana University School of Dentistry, Indiana University Purdue University Indianapolis
| |
Collapse
|
19
|
Par M, Marovic D, Attin T, Tarle Z, Tauböck TT. Effect of rapid high-intensity light-curing on polymerization shrinkage properties of conventional and bulk-fill composites. J Dent 2020; 101:103448. [DOI: 10.1016/j.jdent.2020.103448] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 07/12/2020] [Accepted: 08/04/2020] [Indexed: 12/17/2022] Open
|
20
|
The effect of rapid high-intensity light-curing on micromechanical properties of bulk-fill and conventional resin composites. Sci Rep 2020; 10:10560. [PMID: 32601442 PMCID: PMC7324583 DOI: 10.1038/s41598-020-67641-y] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Accepted: 06/11/2020] [Indexed: 01/08/2023] Open
Abstract
Rapid high-intensity light-curing of dental resin composites is attractive from a clinical standpoint due to the prospect of time-savings. This study compared the effect of high-intensity (3 s with 3,440 mW/cm2) and conventional (10 s with 1,340 mW/cm2) light-curing on micromechanical properties of conventional and bulk-fill resin composites, including two composites specifically designed for high-intensity curing. Composite specimens were prepared in clinically realistic layer thicknesses. Microhardness (MH) was measured on the top and bottom surfaces of composite specimens 24 h after light-curing (initial MH), and after subsequent immersion for 24 h in absolute ethanol (ethanol MH). Bottom/top ratio for initial MH was calculated as a measure of depth-dependent curing effectiveness, whereas ethanol/initial MH ratio was calculated as a measure of crosslinking density. High-intensity light-curing showed a complex material-dependent effect on micromechanical properties. Most of the sculptable composites showed no effect of the curing protocol on initial MH, whereas flowable composites showed 11–48% lower initial MH for high-intensity curing. Ethanol/initial MH ratios were improved by high-intensity curing in flowable composites (up to 30%) but diminished in sculptable composites (up to 15%). Due to its mixed effect on MH and crosslinking density in flowable composites, high-intensity curing should be used with caution in clinical work.
Collapse
|
21
|
Shimokawa C, Turbino ML, Giannini M, Braga RR, Price RB. Effect of Curing Light and Exposure Time on the Polymerization of Bulk-Fill Resin-Based Composites in Molar Teeth. Oper Dent 2020; 45:E141-E155. [PMID: 32053458 DOI: 10.2341/19-126-l] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVES This study examined the influence of different light-curing units (LCUs) and exposure times on the microhardness across bulk-fill resin-based composite (RBC) restorations in a molar tooth. METHODS AND MATERIALS Tip diameter, radiant power, radiant exitance, emission spectra, and light beam profile were measured on two single-emission-peak LCUs (Celalux 3 and DeepCure-S) and two multiple-peak LCUs (Bluephase 20i and Valo Grand). A mold was made using a human molar that had a 12-mm mesial-distal length, a 2.5-mm deep occlusal box, and two 4.5-mm deep proximal boxes. Two bulk-fill RBCs (Filtek Bulk Fill Posterior and Tetric EvoCeram Bulk Fill) were photoactivated for 10 seconds and for 20 seconds, with the light guide positioned at the center of the occlusal surface. Microhardness was then measured across the transverse surface of the restorations. The light that reached the bottom of the proximal boxes was examined. Data were statistically analyzed with the Student t-test, two-way analysis of variance, and the Tukey post hoc test (α=0.05). RESULTS The four LCUs were different regarding all the tested characteristics. Even when using LCUs with wide tips and a homogeneous beam profile, there were significant differences in the microhardness results obtained at the central and proximal regions of the RBCs (p<0.05). LCUs with wider tips used for 20 seconds produced higher microhardness values (p<0.05). The multiple-peak LCUs produced greater hardness values in Tetric EvoCeram Bulk Fill than did the single-emission-peak LCUs (Celalux 3 and DeepCure-S). Results for the light measured at the bottom of proximal boxes showed that little light reached these regions when the light tip was positioned at the center of restorations. CONCLUSIONS Curing lights with wide tips, homogeneous light beam profiles, and longer exposure times are preferred when light-curing large MOD restorations. Light curing from more than one position may be required for adequate photopolymerization.
Collapse
|
22
|
Palagummi SV, Hong T, Wang Z, Moon CK, Chiang MYM. Resin viscosity determines the condition for a valid exposure reciprocity law in dental composites. Dent Mater 2019; 36:310-319. [PMID: 31866065 DOI: 10.1016/j.dental.2019.12.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 12/04/2019] [Accepted: 12/04/2019] [Indexed: 10/25/2022]
Abstract
OBJECTIVE To provide conditions for the validity of the exposure reciprocity law as it pertains to the photopolymerization of dimethacrylate-based dental composites. METHODS Composites made from different mass ratios of resin blends (Bis-GMA/TEGDMA and UDMA/TEGDMA) and silanized micro-sized glass fillers were used. All the composites used camphorquinone and ethyl 4-dimethylaminobenzoate as the photo initiator system. A cantilever beam-based instrument (NIST SRI 6005) coupled with NIR spectroscopy and a microprobe thermocouple was used to simultaneously measure the degree of conversion (DC), the polymerization stress (PS) due to the shrinkage, and the temperature change (TC) in real time during the photocuring process. The instrument has an integrated LED light curing unit providing irradiances ranging from 0.01W/cm2 to 4W/cm2 at a peak wavelength of 460nm (blue light). Vickers hardness of the composites was also measured. RESULTS For every dental composite there exists a minimum radiant exposure required for an adequate polymerization (i.e., insignificant increase in polymerization with any further increase in the radiant exposure). This minimum predominantly depends on the resin viscosity of composite and can be predicted using an empirical equation established based on the test results. If the radiant exposure is above this minimum, the exposure reciprocity law is valid with respect to DC for high-fill composites (filler contents >50% by mass) while invalid for low-fill composites (that are clinically irrelevant). SIGNIFICANCE The study promotes better understanding on the applicability of the exposure reciprocity law for dental composites. It also provides a guidance for altering the radiant exposure, with the clinically available curing light unit, needed to adequately cure the dental composite in question.
Collapse
Affiliation(s)
- Sri Vikram Palagummi
- Biosystems and Biomaterials Division, National Institute of Standards and Technology, Gaithersburg, MD, United States
| | - Taeseung Hong
- Biosystems and Biomaterials Division, National Institute of Standards and Technology, Gaithersburg, MD, United States; Department of Materials Science and Engineering, Pukyong National University, Busan, Republic of Korea
| | - Zhengzhi Wang
- Department of Engineering Mechanics, School of Civil Engineering, Wuhan University, Wuhan, Hubei, China
| | - Chang Kwon Moon
- Department of Materials Science and Engineering, Pukyong National University, Busan, Republic of Korea
| | - Martin Y M Chiang
- Biosystems and Biomaterials Division, National Institute of Standards and Technology, Gaithersburg, MD, United States.
| |
Collapse
|
23
|
Hasslen JA, Barkmeier WW, Shaddy RS, Little JR. Depth of cure of high-viscosity bulk-fill and conventional resin composites using varying irradiance exposures with a light-emitting diode curing unit. J Oral Sci 2019; 61:425-430. [PMID: 31341121 DOI: 10.2334/josnusd.18-0245] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
The purpose of this study was to determine the depth of cure (DOC) of three resin-based composites (RBCs) using varying irradiance exposures with a corded light-emitting diode curing unit. DOCs for Filtek Z250, TPH Spectra, and Tetric EvoCeram Bulk Fill were determined using the International Organization for Standardization (ISO) Standard 4049. The RBCs were light-polymerized using three different power modes and manufacturer-recommended curing times. Irradiance was determined using a spectrometer sensor and the total energy density was calculated for each power mode and concomitant polymerization time. The DOC data were analyzed with a two-way analysis of variance and Tukey's post hoc test. Tetric EvoCeram Bulk Fill produced significantly greater DOCs than TPH and Z250 (P < 0.05) for all three power mode settings. Overall, the DOC of Tetric EvoCeram Bulk Fill was greater than those of TPH and Z250 at all power settings, but the individual RBCs did not show a significant DOC difference among the three power settings (P > 0.05).
Collapse
Affiliation(s)
- Jennifer A Hasslen
- Department of General Dentistry, Creighton University School of Dentistry
| | - Wayne W Barkmeier
- Department of General Dentistry, Creighton University School of Dentistry
| | - Raymond S Shaddy
- Department of General Dentistry, Creighton University School of Dentistry
| | - Jared R Little
- Department of General Dentistry, Creighton University School of Dentistry
| |
Collapse
|
24
|
Al-Zain AO, Eckert GJ, Platt JA. The Influence of Distance on Radiant Exposure and Degree of Conversion Using Different Light-Emitting-Diode Curing Units. Oper Dent 2019; 44:E133-E144. [DOI: 10.2341/18-004-l] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objectives:
To investigate the influence of curing distance on the degree of conversion (DC) of a resin-based composite (RBC) when similar radiant exposure was achieved using six different light-curing units (LCUs) and to explore the correlation among irradiance, radiant exposure, and DC.
Methods and Materials:
A managing accurate resin curing-resin calibrator system was used to collect irradiance data for both top and bottom specimen surfaces with a curing distance of 2 mm and 8 mm while targeting a consistent top surface radiant exposure. Square nanohybrid-dual-photoinitiator RBC specimens (5 × 5 × 2 mm) were cured at each distance (n=6/LCU/distance). Irradiance and DC (micro-Raman spectroscopy) were determined for the top and bottom surfaces. The effect of distance and LCU on irradiance, radiant exposure, and DC as well as their linear associations were analyzed using analysis of variance and Pearson correlation coefficients, respectively (α=0.05).
Results:
While maintaining a similar radiant exposure, each LCU exhibited distinctive patterns in decreased irradiance and increased curing time. No significant differences in DC values (63.21%-70.28%) were observed between the 2- and 8-mm distances, except for a multiple-emission peak LCU. Significant differences in DC were detected among the LCUs. As expected, irradiance and radiant exposure were significantly lower on the bottom surfaces. However, a strong correlation between irradiance and radiant exposure did not necessarily result in a strong correlation with DC.
Conclusions:
The RBC exhibited DC values >63% when the top surface radiant exposure was maintained, although the same values were not reached for all lights. A moderate-strong correlation existed among irradiance, radiant exposure, and DC.
Collapse
Affiliation(s)
- AO Al-Zain
- Afnan O Al-Zain, BDS, MSD, PhD, King Abdulaziz University, Faculty of Dentistry, Restorative Dentistry Department, Jeddah, Saudi Arabia
| | - GJ Eckert
- George J Eckert, MS, Indiana University School of Medicine, Division of Biostatistics, Indianapolis, IN, USA
| | - JA Platt
- Jeffrey A Platt, DDS, MS, Indiana University, Department of Biomedical and Applied Sciences, Indianapolis, IN, USA
| |
Collapse
|
25
|
Al-Zain AO, Eckert GJ, Lukic H, Megremis S, Platt JA. Polymerization pattern characterization within a resin-based composite cured using different curing units at two distances. Clin Oral Investig 2019; 23:3995-4010. [PMID: 30737620 DOI: 10.1007/s00784-019-02831-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Accepted: 01/25/2019] [Indexed: 12/14/2022]
Abstract
OBJECTIVES To investigate the relationship of the irradiance-beam-profile areas from six different light-curing units (LCUs) with the degree of conversion (DC), microhardness (KH), and cross-link density (CLD) throughout a resin-based composite (RBC) cured at two clinically relevant distances, and to explore the correlations among them. MATERIALS AND METHODS A mapping approach was used to measure DC using micro-Raman spectroscopy, KH using a Knoop indentor on a hardness tester, and %KH reduction after ethanol exposure, as an indicator for CLD within a nano-hybrid RBC increment (n = 3) at various depths. These sample composites were cured from two distances while maintaining the radiant exposure, using six different light-curing units: one quartz-tungsten-halogen; two single and three multiple-emission-peak light-emitting-diode units. Irradiance beam profiles were generated for each LCU at both distances, and localized irradiance values were calculated. Points across each depth were analyzed using repeated measures ANOVA. Correlations across multiple specimen locations and associations between beam uniformity corresponding with polymerization measurements were calculated using linear mixed models and Pearson correlation coefficients. RESULTS Significant non-uniform polymerization patterns occurred within the specimens at various locations and depths. At 2-mm curing distance, the localized DC = 52.7-76.8%, KH = 39.0-66.7 kg/mm2, and %KH reduction = 26.7-57.9%. At 8-mm curing distance, the localized DC = 50.4-78.6%, KH = 40.3-73.7 kg/mm2, and %KH reduction = 28.2-56.8%. The localized irradiance values were weakly correlated with the corresponding DC, KH, and %KH reduction, with only a few significant correlations (p < 0.05). CONCLUSIONS Although significant differences were observed at each depth within the specimens, the localized irradiance values for all LCUs did not reflect the polymerization pattern and did not seem to have a major influence on polymerization patterns within the RBC, regardless of the curing distance. CLINICAL RELEVANCE Commonly used LCUs do not produce uniform polymerization regardless of the curing distance, which may contribute to the risk of RBC fracture.
Collapse
Affiliation(s)
- Afnan O Al-Zain
- Restorative Dentistry Department, Faculty of Dentistry, King Abdulaziz University, P.O. Box: 80209, Jeddah, 21589, Saudi Arabia.
| | - George J Eckert
- Department of Biostatistics, Indiana University School of Medicine, Indiana University Purdue University Indianapolis, Indianapolis, IN, USA
| | - Henry Lukic
- Research and Standards, American Dental Association Science Institute, Chicago, IL, USA
| | - Spiro Megremis
- Research and Standards, American Dental Association Science Institute, Chicago, IL, USA
| | - Jeffrey A Platt
- Department of Biomedical and Applied Sciences, Indiana University School of Dentistry, Indiana University Purdue University Indianapolis, Indianapolis, IN, USA
| |
Collapse
|
26
|
Cuevas-Suárez CE, Meereis CTW, D'accorso N, Macchi R, Ancona-Meza AL, Zamarripa-Calderón E. Effect of radiant exposure and UV accelerated aging on physico-chemical and mechanical properties of composite resins. J Appl Oral Sci 2019; 27:e20180075. [PMID: 30624462 PMCID: PMC6322643 DOI: 10.1590/1678-7757-2018-0075] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2018] [Accepted: 09/09/2018] [Indexed: 12/04/2022] Open
Abstract
Currently, there is no consensus in terms of defining the minimum radiant exposure values necessary for achieving adequate properties of composite resin. In addition, the long-term influence that radiant exposure has on the properties of composite resins is still questionable. Objective: The objective of this study was to evaluate the effect of radiant exposure and UV accelerated aging on the physico-chemical and mechanical properties of micro-hybrid and nanofilled composite resins. Material and Methods: A nanofilled (Filtek Supreme; 3M ESPE) and a micro-hybrid composite resin (Filtek Z250; 3M ESPE) were investigated under different radiant exposures (3.75, 9, and 24 J/cm2) and UV accelerated aging protocols (0, 500, 1000, and 1500 aging hours). The degree of conversion (DC), flexural strength (FS), modulus (M), water sorption (WS), and solubility (WL) were evaluated. The results obtained were analyzed using two-way ANOVA and Tukey's test. Comparisons were performed using a significance level of α=0.05. Results: The DC, FS, and M were found to be significantly influenced by both radiant exposure and accelerated aging time. The DC and EM increased with radiant exposure in the no-aging group (0-hour aging) for both micro-hybrid and nanofilled composites, whereas no correlation was found after accelerated aging protocols. WS and WL of micro-hybrid and nanofilled composite resins were scarcely affected by radiant exposure (p>0.05), whereas they were significantly reduced by accelerated aging (p<0.001). Conclusions: Although increasing radiant exposure affected the degree of conversion and mechanical properties of micro-hybrid and nanofilled composites, no influence on the hydrolytic degradation of the material was observed. In contrast, UV accelerated aging affected both the physico-chemical and mechanical properties of the composites.
Collapse
Affiliation(s)
- Carlos Enrique Cuevas-Suárez
- Universidad Autónoma del Estado de Hidalgo, Instituto de Ciencias de la Salud, Área Académica de Odontología, Pachuca de Soto, México
| | - Carine Tais Walter Meereis
- Universidade Federal dos Vales do Jequitinhonha e Mucuri, Programa de Pós-Graduação em Odontologia, Diamantina, Minas Gerais, Brasil
| | - Norma D'accorso
- Universidad de Buenos Aires, Facultad de Ciencias Exactas y Naturales, Departamento de Química Orgánica, Buenos Aires, Argentina
| | - Ricardo Macchi
- Universidad de Buenos Aires, Facultad de Odontología, Departamento de Materiales Dentales, Buenos Aires, Argentina
| | - Adriana Leticia Ancona-Meza
- Universidad Autónoma del Estado de Hidalgo, Instituto de Ciencias de la Salud, Área Académica de Odontología, Pachuca de Soto, México
| | - Eliezer Zamarripa-Calderón
- Universidad Autónoma del Estado de Hidalgo, Instituto de Ciencias de la Salud, Área Académica de Odontología, Pachuca de Soto, México
| |
Collapse
|
27
|
Lempel E, Őri Z, Szalma J, Lovász BV, Kiss A, Tóth Á, Kunsági-Máté S. Effect of exposure time and pre-heating on the conversion degree of conventional, bulk-fill, fiber reinforced and polyacid-modified resin composites. Dent Mater 2018; 35:217-228. [PMID: 30503020 DOI: 10.1016/j.dental.2018.11.017] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2018] [Revised: 10/03/2018] [Accepted: 11/14/2018] [Indexed: 01/16/2023]
Abstract
OBJECTIVE To determine the degree of conversion (DC) of different type of resin-based composites (RBC) in eight-millimeter-deep clinically relevant molds, and investigate the influence of exposure time and pre-heating on DC. METHODS Two-millimeter-thick samples of conventional sculptable [FiltekZ250 (FZ)], flowable [Filtek Ultimate Flow (FUF)] and polyacid-modified [Twinky Star Flow (TS)] RBCs, and four-millimeter-thick samples of flowable bulk-fill [Filtek Bulk Fill Flow (FBF), Surefil SDR (SDR)] and sculptable fibre-reinforced [EverX Posterior (EX)] RBCs were prepared in an eight-millimeter-deep mold. The RBCs temperature was pre-set to 25, 35 and 55°C. The RBCs were photopolymerized with the recommended and its double exposure time. The DC at the top and bottom was measured with micro-Raman spectroscopy. Data were analyzed with ANOVA and Scheffe post-hoc test (p<0.05). RESULTS The differences in DC% between the top/bottom and the recommended/extended exposure time were significant for the materials, except SDR (64.5/63.0% and 67.4/63.0%). FUF (69.0% and 53.4%) and TS (64.9% and 60.9%) in 2mm provided higher DC% at the top and bottom with the recommended curing time, compared to the other materials, except SDR. Pre-heating had negative effect on DC at the bottom in flowable RBCs (FUF: 48.9%, FBF: 36.7%, SDR: 43%, TS: 54.7%). Pre-heating to 55 °C significantly increased the DC% in fibre-reinforced RBC (75.0% at the top, 64.7% at the bottom). SIGNIFICANCE Increased exposure time improves the DC for each material. Among bulk-fills, only SDR performed similarly, compared to the two-millimeter-thick flowable RBCs. Pre-heating of low-viscosity RBCs decreased the DC% at the bottom. Pre-heating of fibre-reinforced RBC to 55°C increased the DC% at a higher rate than the extended curing time.
Collapse
Affiliation(s)
- Edina Lempel
- Department of Restorative Dentistry and Periodontology, University of Pécs, Pécs, Hungary.
| | - Zsuzsanna Őri
- Department of General and Physical Chemistry, University of Pécs, 6 Ifjúság Street, Pécs, H-7624, Hungary; János Szentágothai Research Center, 20 Ifjúság Street, Pécs, H-7624, Hungary
| | - József Szalma
- Department of Oral and Maxillofacial Surgery, University of Pécs, Pécs, Hungary
| | - Bálint Viktor Lovász
- Department of Restorative Dentistry and Periodontology, University of Pécs, Pécs, Hungary
| | - Adél Kiss
- Department of Restorative Dentistry and Periodontology, University of Pécs, Pécs, Hungary
| | - Ákos Tóth
- Faculty of Sciences, University of Pécs Pécs, Hungary
| | - Sándor Kunsági-Máté
- Department of General and Physical Chemistry, University of Pécs, 6 Ifjúság Street, Pécs, H-7624, Hungary; János Szentágothai Research Center, 20 Ifjúság Street, Pécs, H-7624, Hungary
| |
Collapse
|
28
|
Examining the Effect of Radiant Exposure on Commercial Photopolimerizable Dental Resin Composites. Dent J (Basel) 2018; 6:dj6040055. [PMID: 30301279 PMCID: PMC6313541 DOI: 10.3390/dj6040055] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Accepted: 10/04/2018] [Indexed: 11/17/2022] Open
Abstract
The objective of this study was to evaluate the effect of radiant exposure on the chemical and physical properties of four commercial dental resin composites. The four dental resin composites used were Kalore, Admira, Tetric N-Ceram Bulk Fill, and Filtek Z350 XT. The composites were subjected to three curing protocols: 1000 mW/cm2 for 5 s, 1000 mW/cm2 for 10 s, and 400 mW/cm2 for 25 s. The flexural strength, elastic modulus, water sorption, water solubility, degree of conversion, and polymerization shrinkage were evaluated. The results were analyzed by means of ANOVA and Tukey tests. For Admira and Kalore, significant differences between light exposure protocols were observed for the elastic modulus (p < 0.001), which was higher when a higher amount of radiant exposure was used. For Filtek Z350, differences were only observed for the degree of conversion (p < 0.001), and a higher amount of radiant exposure allowed us to obtain higher values. The Tetric N-Ceram Bulk Fill analysis showed significant differences for the elastic modulus and water sorption (p < 0.001), and specimens that had been subject to a radiant exposure of 10 J/cm2 showed a higher elastic modulus. In most cases, the physical and mechanical properties analyzed were not affected by different radiant exposure values. Other resin-based composite (RBC) characteristics seem to have a greater influence on material properties.
Collapse
|
29
|
Daugherty MM, Lien W, Mansell MR, Risk DL, Savett DA, Vandewalle KS. Effect of high-intensity curing lights on the polymerization of bulk-fill composites. Dent Mater 2018; 34:1531-1541. [DOI: 10.1016/j.dental.2018.06.005] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2018] [Revised: 05/25/2018] [Accepted: 06/07/2018] [Indexed: 10/28/2022]
|
30
|
Germscheid W, de Gorre LG, Sullivan B, O’Neill C, Price RB, Labrie D. Post-curing in dental resin-based composites. Dent Mater 2018; 34:1367-1377. [DOI: 10.1016/j.dental.2018.06.021] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Revised: 06/06/2018] [Accepted: 06/07/2018] [Indexed: 11/16/2022]
|
31
|
Shimokawa CAK, Turbino ML, Giannini M, Braga RR, Price RB. Effect of light curing units on the polymerization of bulk fill resin-based composites. Dent Mater 2018; 34:1211-1221. [PMID: 29801683 DOI: 10.1016/j.dental.2018.05.002] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Revised: 04/15/2018] [Accepted: 05/02/2018] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To determine the potential effect of four different light curing units (LCUs) on the curing profile of two bulk fill resin-based composites (RBCs). METHODS Four LCUs (Bluephase 20i, Celalux 3, Elipar DeepCure-S and Valo Grand) were used to light cure two RBCs (Filtek Bulk Fill Posterior Restorative and Tetric EvoCeram Bulk Fill). The effective tip diameter, radiant power, radiant emittance, emission spectrum and light beam profile of the LCUs were measured. Knoop microhardness was measured at the top and bottom surfaces of RBC specimens that were 12-mm in diameter and 4-mm deep (n=5). The distribution of the spectral radiant power that was delivered to the surface of the specimen and the light transmission through the 4-mm thick specimens was measured using an integrating sphere. Two-way ANOVA and Tukey tests (α=0.05) were applied. RESULTS The Valo Grand produced the most homogeneous microhardness across the surfaces of the RBCs (p>0.05). When the Celalux 3, Bluephase 20i and Elipar DeepCure-S lights were used, the center of the specimens achieved greater hardness values compared to their outer regions (p<0.05). Approximately 10% of the radiant power delivered to the top reached the bottom of the specimen, although almost no violet light passed through 4mm of either RBC. A positive correlation was observed between the radiant exposure and microhardness. SIGNIFICANCE The characteristics of the LCUs influenced the photoactivation of the RBCs. The use of a wide tip with a homogeneous light distribution is preferred when light curing RBCs using a bulk curing technique.
Collapse
Affiliation(s)
| | - Míriam Lacalle Turbino
- University of São Paulo, School of Dentistry, Restorative Dentistry, São Paulo, São Paulo, Brazil.
| | - Marcelo Giannini
- University of Campinas, Piracicaba Dental School, Restorative Dentistry, Piracicaba, São Paulo, Brazil.
| | - Roberto Ruggiero Braga
- University of São Paulo, School of Dentistry, Biomaterials and Oral Biology, São Paulo, São Paulo, Brazil.
| | - Richard Bengt Price
- Dalhousie University, Faculty of Dentistry, Dental Clinical Sciences, 5981 University Ave., Halifax, Nova Scotia, B3H 4R2, Canada.
| |
Collapse
|
32
|
Ferracane J, Hilton T, Stansbury J, Watts D, Silikas N, Ilie N, Heintze S, Cadenaro M, Hickel R. Academy of Dental Materials guidance—Resin composites: Part II—Technique sensitivity (handling, polymerization, dimensional changes). Dent Mater 2017; 33:1171-1191. [DOI: 10.1016/j.dental.2017.08.188] [Citation(s) in RCA: 80] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Accepted: 08/29/2017] [Indexed: 11/30/2022]
|
33
|
Abstract
The ability to light cure resins 'on demand' in the mouth has revolutionized dentistry. However, there is a widespread lack of understanding of what is required for successful light curing in the mouth. Most instructions simply tell the user to 'light cure for xx seconds' without describing any of the nuances of how to successfully light cure a resin. This article provides a brief description of light curing. At the end, some recommendations are made to help when purchasing a curing light and how to improve the use of the curing light.
Collapse
Affiliation(s)
- Richard B T Price
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia B3H 4R2, Canada.
| |
Collapse
|
34
|
Al-Zain AO, Eckert GJ, Lukic H, Megremis SJ, Platt JA. Degree of conversion and cross-link density within a resin-matrix composite. J Biomed Mater Res B Appl Biomater 2017; 106:1496-1504. [DOI: 10.1002/jbm.b.33960] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Revised: 06/22/2017] [Accepted: 07/04/2017] [Indexed: 11/06/2022]
Affiliation(s)
- Afnan O. Al-Zain
- Department of Operative Dentistry; Faculty of Dentistry, King Abdulaziz University; Jeddah Kingdom of Saudi Arabia
- Department of Biomedical and Applied Sciences; Indiana University School of Dentistry, Indiana University Purdue University Indianapolis; Indianapolis IN
| | - George J. Eckert
- Biostatistician Supervisor; Department of Biostatistics, Indiana University School of Medicine, Indiana University Purdue University Indianapolis; Indianapolis IN
| | - Henry Lukic
- Research and Laboratories, American Dental Association Division of Science; Chicago IL
| | - Spiro J. Megremis
- Research and Laboratories, American Dental Association Division of Science; Chicago IL
| | - Jeffrey A. Platt
- Department of Biomedical and Applied Sciences; Indiana University School of Dentistry, Indiana University Purdue University Indianapolis; Indianapolis IN
| |
Collapse
|
35
|
Shimokawa C, Sullivan B, Turbino ML, Soares CJ, Price RB. Influence of Emission Spectrum and Irradiance on Light Curing of Resin-Based Composites. Oper Dent 2017; 42:537-547. [PMID: 28581917 DOI: 10.2341/16-349-l] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE This study examined the influence of different emission spectra (single-peak and broad-spectrum) light-curing units (LCUs) delivering the same radiant exposures at irradiance values of 1200 or 3600 mW/cm2 on the polymerization and light transmission of four resin-based composites (RBCs). METHODS AND MATERIALS Two prototype LCUs that used the same light tip, but were either a single-peak blue or a broad-spectrum LED, were used to deliver the same radiant exposures to the top surfaces of the RBCs using either standard (1200 mW/cm2) or high irradiance (3600 mW/cm2) settings. The emission spectrum and radiant power from the LCUs were measured with a laboratory-grade integrating sphere coupled to a spectrometer, and the light beam was assessed with a beam profiler camera. Four RBCs (Filtek Supreme Ultra A2, Tetric EvoCeram A2, Tetric EvoCeram T, and TPH Spectra High Viscosity A2) were photoactivated using four different light conditions: single-peak blue/standard irradiance, single-peak blue/high irradiance, broad-spectrum/standard irradiance, and broad-spectrum/high irradiance. The degree of conversion (N=5) and microhardness at the top and bottom of 2.3-mm-diameter by 2.5-mm-thick specimens (N=5) were analyzed with analysis of variance and Tukey tests. The real-time light transmission through the RBCs was also measured. RESULTS For all light conditions, the 2.3-mm-diameter specimens received a homogeneous irradiance and spectral distribution. Although similar radiant exposures were delivered to the top surfaces of the RBCs, the amount of light energy emitted from the bottom surfaces was different among the four RBCs, and was also greater for the single-peak lights. Very little violet light (wavelengths below 420 nm) reached the bottom of the 2.5-mm-thick specimens. The degree of conversion and microhardness results varied according to the RBC (p<0.05). The RBCs that included alternative photoinitiators had greater microhardness values at the top when cured with broad-spectrum lights, while at the bottom, where little violet light was observed, the results were equal or higher when they were photoactivated with single-peak blue lights. With the exception of the microhardness at the top of TPH, equivalent or higher microhardness and degree-of-conversion values were achieved at the bottom surface when the standard (1200 mW/cm2) irradiance levels were used compared to when high irradiance levels were used. CONCLUSIONS Considering the different behaviors of the tested RBCs, the emission spectrum and irradiance level influenced the polymerization of some RBCs. The RBCs that included alternative photoinitiators produced greater values at the top when cured with broad-spectrum lights, while at the bottom, results were equal or higher for the RBCs photoactivated with single-peak blue lights.
Collapse
|
36
|
Cardoso KAORDF, Zarpellon DC, Madruga CFL, Rodrigues JA, Arrais CAG. Effects of radiant exposure values using second and third generation light curing units on the degree of conversion of a lucirin-based resin composite. J Appl Oral Sci 2017; 25:140-146. [PMID: 28403354 PMCID: PMC5393534 DOI: 10.1590/1678-77572016-0388] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2016] [Accepted: 10/10/2016] [Indexed: 11/21/2022] Open
Abstract
Objective Using Fourier transform infrared analysis (FTIR) in vitro, the effects of varying radiant exposure (RE) values generated by second and third generation LED LCUs on the degree of conversion (DC) and maximum rate of polymerization (Rpmax) of an experimental Lucirin TPO-based RC were evaluated. Material and Methods 1 mm or 2 mm thick silicon molds were positioned on a horizontal attenuated total reflectance (ATR) unit attached to an infrared spectroscope. The RC was inserted into the molds and exposed to varying REs (18, 36 and 56 J/cm2) using second (Radii Plus, SDI) and third generation LED LCUs (Bluephase G2/Ivoclar Vivadent) or a quartz tungsten based LCU (Optilux 501/SDS Kerr). FTIR spectra (n=7) were recorded for 10 min (1 spectrum/s, 16 scans/spectrum, resolution 4 cm-1) immediately after their application to the ATR. The DC was calculated using standard techniques for observing changes in aliphatic to aromatic peak ratios both prior to, and 10 min after curing, as well as during each 1 second interval. DC and Rpmax data were analyzed using 3-way ANOVA and Tukey's post-hoc test (p=0.05). Results No significant difference in DC or Rpmax was observed between the 1 mm or 2 mm thick specimens when RE values were delivered by Optilux 501 or when the 1 mm thick composites were exposed to light emitted by Bluephase G2, which in turn promoted a lower DC when 18 J/cm2 (13 s) were delivered to the 2 mm thick specimens. Radii Plus promoted DC and Rpmax values close to zero under most conditions, while the delivery of 56 J/cm2 (40 s) resulted in low DC values. Conclusions The third generation LCU provided an optimal polymerization of Lucirin TPO-based RC under most tested conditions, whereas the second generation LED-curing unit was useless regardless of the RE.
Collapse
|
37
|
AlShaafi MM. Effects of delivering the same radiant exposures at 730, 1450, and 2920 mW/cm 2 to two resin-based composites. Eur J Dent 2017; 11:22-28. [PMID: 28435361 PMCID: PMC5379830 DOI: 10.4103/ejd.ejd_270_16] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Objective: To evaluate the effects of curing two resin-based composites (RBC) with the same radiant exposures at 730, 1450, and 2920 mW/cm2. Materials and Methods: Two types of RBC, Filtek Supreme Ultra and Tetric-EvoCeram-Bulk Fill, were light-cured to deliver the same radiant exposures for 5, 10, or 20 s by means of a modified Valo light emitted diode light-curing unit with the light tip placed directly over each specimen. The RBC was expressed into metal rings that were 2.0 and 4.0 mm in thickness, directly on an attenuated total reflectance Fourier transform infrared plate heated to 33°C, and the degree of conversion (DC) of the RBC was recorded. The specimens were then removed and the Knoop microhardness (KHN) was tested at both the bottom and the top of each specimen. The KHN was tested again after 24 h and 7 days of storage in the dark at 37°C and 100% humidity. The DC and KHN results were analyzed with Fisher's protected least significant difference at α = 0.05. Results: The DC values for the specimens cured at the three different irradiance levels were similar. However, at different depths, there were differences in the DC values. In general, there were no clear differences among the samples cured in the three different groups, and the KHN was always greater 24 h and 7 days later (P < 0.05). Conclusions: Despite the curing time, and as long as the samples were cured with the same radiant exposures, there were no significant effects on the DC and KHN of both RBCs.
Collapse
Affiliation(s)
- Maan M AlShaafi
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
38
|
AlShaafi MM. Factors affecting polymerization of resin-based composites: A literature review. Saudi Dent J 2017; 29:48-58. [PMID: 28490843 PMCID: PMC5411902 DOI: 10.1016/j.sdentj.2017.01.002] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2016] [Revised: 01/28/2017] [Accepted: 01/29/2017] [Indexed: 11/15/2022] Open
Abstract
AIM The aim of this review was to help clinicians improve their understanding of the polymerization process for resin-based composites (RBC), the effects of different factors on the process and the way in which, when controlled, the process leads to adequately cured RBC restorations. METHODS Ten factors and their possible effects on RBC polymerization are reviewed and discussed, with some recommendations to improve that process. These factors include RBC shades, their light curing duration, increment thickness, light unit system used, cavity diameter, cavity location, light curing tip distance from the curing RBC surface, substrate through which the light is cured, filler type, and resin/oral cavity temperature. CONCLUSION The results of the review will guide clinicians toward the best means of providing their patients with successfully cured RBC restorations.
Collapse
Affiliation(s)
- Maan M AlShaafi
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
39
|
Effect of High-Irradiance Light-Curing on Micromechanical Properties of Resin Cements. BIOMED RESEARCH INTERNATIONAL 2016; 2016:4894653. [PMID: 28044129 PMCID: PMC5164896 DOI: 10.1155/2016/4894653] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/19/2016] [Revised: 11/11/2016] [Accepted: 11/17/2016] [Indexed: 11/24/2022]
Abstract
This study investigated the influence of light-curing at high irradiances on micromechanical properties of resin cements. Three dual-curing resin cements and a light-curing flowable resin composite were light-cured with an LED curing unit in Standard mode (SM), High Power mode (HPM), or Xtra Power mode (XPM). Maximum irradiances were determined using a MARC PS radiometer, and exposure duration was varied to obtain two or three levels of radiant exposure (SM: 13.2 and 27.2 J/cm2; HPM: 15.0 and 30.4 J/cm2; XPM: 9.5, 19.3, and 29.7 J/cm2) (n = 17). Vickers hardness (HV) and indentation modulus (EIT) were measured at 15 min and 1 week. Data were analyzed with nonparametric ANOVA, Wilcoxon-Mann-Whitney tests, and Spearman correlation analyses (α = 0.05). Irradiation protocol, resin-based material, and storage time and all interactions influenced HV and EIT significantly (p ≤ 0.0001). Statistically significant correlations between radiant exposure and HV or EIT were found, indicating that high-irradiance light-curing has no detrimental effect on the polymerization of resin-based materials (p ≤ 0.0021). However, one resin cement was sensitive to the combination of irradiance and exposure duration, with high-irradiance light-curing resulting in a 20% drop in micromechanical properties. The results highlight the importance of manufacturers issuing specific recommendations for the light-curing procedure of each resin cement.
Collapse
|
40
|
Mouhat M, Mercer J, Stangvaltaite L, Örtengren U. Light-curing units used in dentistry: factors associated with heat development-potential risk for patients. Clin Oral Investig 2016; 21:1687-1696. [PMID: 27695955 PMCID: PMC5442227 DOI: 10.1007/s00784-016-1962-5] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Accepted: 09/14/2016] [Indexed: 11/25/2022]
Abstract
Objectives To investigate how heat development in the pulp chamber and coronal surface of natural teeth with and without cusps subjected to irradiance using light-emitting diode (LED)–light-curing units (LCUs) is associated with (i) irradiance, (ii) time, (iii) distance, and (iv) radiant exposure. Materials and methods Three different LED-LCUs were used. Their irradiance was measured with a calibrated spectrometer (BlueLight Analytics Inc., Halifax, Canada). An experimental rig was constructed to control the thermal environment of the teeth. The LED-LCU tip position was accurately controlled by a gantry system. Tooth surface temperature was measured by thermography (ThermaCAM S65 HS, FLIR Systems, Wilsonville, USA) and pulp chamber temperature with a thermocouple. LED-LCU tip distance and irradiation times tested were 0, 2, and 4 mm and 10, 20, and 30 s, respectively. Ethical permission was not required for the use of extracted teeth. Results Maximum surface and pulp chamber temperatures were recorded in tooth without cusps (58.1 °C ± 0.9 °C and 43.1 °C ± 0.9 °C, respectively). Radiant exposure explained the largest amount of variance in temperature, being more affected by time than irradiance. Conclusions At all combinations of variables tested, repeated measurements produced consistent results indicating the reliability of the method used. Increased exposure time seems to be the factor most likely to cause tissue damage. Clinical relevance Risk of superficial tissue damage at irradiances >1200 mW/cm2 is evident. There is a risk of pulp damage when only thin dentin is left at higher irradiances (>1200 mW/cm2). Clinicians should be aware of LED-LCU settings and possible high temperature generated.
Collapse
Affiliation(s)
- Mathieu Mouhat
- Department for Clinical Dentistry/Faculty of Health Sciences, The Arctic University of Norway (UIT), Tromsø, Norway
| | - James Mercer
- Department of Medical Biology/Faculty of Health Sciences, The Arctic University of Norway (UIT), Tromsø, Norway
| | - Lina Stangvaltaite
- Department for Clinical Dentistry/Faculty of Health Sciences, The Arctic University of Norway (UIT), Tromsø, Norway
| | - Ulf Örtengren
- Department for Clinical Dentistry/Faculty of Health Sciences, The Arctic University of Norway (UIT), Tromsø, Norway.
- Department of Cariology, Institute of Odontology/Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| |
Collapse
|
41
|
Kostylev I, Winters T, Labrie D, Price RBT. Role of the beam profile and sample geometry in the bonded-disk method on the shrinkage kinetics of two dental resins. Dent Mater 2016; 32:1026-35. [PMID: 27316433 DOI: 10.1016/j.dental.2016.05.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2015] [Accepted: 05/24/2016] [Indexed: 10/21/2022]
Abstract
OBJECTIVE To investigate the time evolution of the two dimensional axial shrinkage field for two dental resins in the bonded disk geometry and further test the bonded-disk method. METHODS An interferometric technique employing a camera was used to image the 2D axial shrinkage field when polymerizing dental resins in real time both during and after light exposure. Four different beam profiles from two light curing units and three sample geometries were utilized to investigate their roles on the 2D axial shrinkage field. RESULTS The 2D axial shrinkage field correlates qualitatively with the beam profile shortly after the start of light exposure but takes on distinct shapes caused by the rigidity of the coverslip, beam profile, and the resin viscoelasticity. SIGNIFICANCE Using the conventional bonded disk geometry and uniform beam profile from a light curing unit, the axial 2D shrinkage field was uniform to within 4% in the central part of bonded disk samples.
Collapse
Affiliation(s)
- I Kostylev
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada B3H 4R2
| | - T Winters
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada B3H 4R2
| | - D Labrie
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada B3H 4R2.
| | - R B T Price
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada B3H 4R2
| |
Collapse
|