1
|
Valenti C, Isabella Federici M, Masciotti F, Marinucci L, Xhimitiku I, Cianetti S, Pagano S. Mechanical properties of 3D printed prosthetic materials compared with milled and conventional processing: A systematic review and meta-analysis of in vitro studies. J Prosthet Dent 2024; 132:381-391. [PMID: 35934576 DOI: 10.1016/j.prosdent.2022.06.008] [Citation(s) in RCA: 22] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 06/22/2022] [Accepted: 06/22/2022] [Indexed: 11/23/2022]
Abstract
STATEMENT OF PROBLEM Three-dimensional (3D) additive manufacturing (AM) is an evolving technology in dentistry, proposed as an alternative to subtractive milling manufacture (MM) or conventional processing. However, a systematic review of the use of AM technology instead of milling or conventional processing is lacking. PURPOSE The purpose of this systematic review and meta-analysis was to evaluate the mechanical properties of 3D printed prosthetic materials compared with MM and conventional techniques. MATERIAL AND METHODS An electronic search of the literature was conducted on the MEDLINE (via PubMed), Scopus, and Web of Science databases. The inclusion criteria were in vitro studies published in the last 5 years, in English or Italian, and with 3D AM printed dental prosthetic materials. Data extraction was focused on dental prosthetic materials (ceramics, polymers, and metals) and their mechanical properties: flexural strength, fracture load, hardness, roughness, removable partial denture (RPD) fit accuracy, trueness, marginal discrepancy, and internal fit. Data considered homogenous were subjected to meta-analysis using the Stata17 statistical software program (95% confidence interval [CI]; α=.05). Since all variables were continuous, the Hedge g measure was calculated. A fixed-effects model was used for I2=0%, while the statistical analysis was conducted using a random-effects model with I2>0%. RESULTS From a total of 3624 articles, 2855 studies were selected, and 76 studies included after full-text reading. The roughness of AM-printed ceramics generally increased compared with that of conventional processing while the marginal discrepancy was comparable both for ceramics and polymers. The flexural strength, hardness, and fracture load of AM-printed polymers were statistically lower than those of the conventional group (P<.05). No significant difference was detected in terms of hardness, roughness, marginal discrepancy, fracture load, trueness, or internal fit between the AM and MM techniques (P>.05). Milling techniques showed significantly higher values of flexural strength (Hedge g=-3.88; 95% CI, -7.20 to -0.58; P=.02), also after aging (Hedge g=-3.29; 95% CI, -6.41 to -0.17; P=.04), compared with AM printing. CONCLUSIONS AM is comparable with MM in terms of mechanical properties, in particular with polymeric materials. The flexural strength of AM-printed prostheses is lower than with conventional and MM techniques, as are the parameters of hardness and fracture load, while the marginal discrepancy is similar to that of MM and conventional techniques. AM prostheses are commonly used for interim crowns and fixed partial dentures, as their rigidity and fracture resistance cannot support mastication forces for extended periods. More comparative studies are needed.
Collapse
Affiliation(s)
- Chiara Valenti
- Graduate student, Department of Medicine and Surgery, Odontostomatological University Centre, University of Perugia, Perugia, Italy
| | - Maria Isabella Federici
- Graduate student, Department of Medicine and Surgery, Odontostomatological University Centre, University of Perugia, Perugia, Italy
| | - Francesca Masciotti
- Student, Department of Medicine and Surgery, Odontostomatological University Centre, University of Perugia, Perugia, Italy
| | - Lorella Marinucci
- Researcher, Section of Biosciences and Medical Embryology, Department of Medicine and Surgery, University of Perugia, Perugia, Italy
| | - Iva Xhimitiku
- PhD student, Centro di Ateneo di Studi e Attività Spaziali "Giuseppe Colombo" - CISAS, University of Padua, Padua, Italy
| | - Stefano Cianetti
- Professor, Department of Medicine and Surgery, Odontostomatological University Centre, University of Perugia, Perugia, Italy
| | - Stefano Pagano
- Researcher, Department of Medicine and Surgery, Odontostomatological University Centre, University of Perugia, Perugia, Italy.
| |
Collapse
|
2
|
Türksayar AAD, Petersmann S, Spintzyk S. The effect of thermomechanical aging on the fracture resistance of additive and subtractive manufactured polyetheretherketone abutments. J Dent 2024:105225. [PMID: 38969266 DOI: 10.1016/j.jdent.2024.105225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Revised: 06/26/2024] [Accepted: 07/02/2024] [Indexed: 07/07/2024] Open
Abstract
OBJECTIVES To evaluate the fracture resistance (FR) of polyetheretherketone (PEEK) abutments produced by additive and subtractive methods compared to milled zirconia abutments. METHODS Custom abutments were designed on Ti-base abutments and produced from three different materials, namely additively manufactured PEEK (PEEK-AM), subtractively manufactured PEEK (PEEK-SM), and zirconia (N=60). PEEK-AM abutments were printed using PEEK filaments (VESTAKEEP®i4 3DF-T, Evonik Industries AG) on a M150 Medical 3D Printer (ORION AM) by fused filament fabrication (FFF). All surface treatments were carried out according to the manufacturer's instructions. All abutments were cemented on Ti-bases with hybrid abutment cement and then restored with milled zirconia crowns. Each subgroup was divided into non-aged and aged subgroups (n=10). The aged groups were subjected to thermomechanical aging (49 N, 5-55°C, 1.2 million cycles). FR tests were performed by using a universal testing machine. Data were statistically analyzed with one-way and two-way ANOVA and t-test. RESULTS The survival rate of the specimens after aging was determined as 100%. It was found that both the material and aging had a significant effect on the FR (p<.001). There was a statistical difference among the fracture values of the groups (p<0.001). In both the aged and non-aged groups, PEEK-AM showed the statistically lowest FR, while the highest FR was seen in the zirconia group, which was significantly higher than the PEEK-SM (p<0.001). CONCLUSION Hybrid abutments were successfully manufactured, and extrusion-based processed PEEK seems to be a good alternative to subtractive processed PEEK. However, since subtractive manufacturing still appears to be superior, further developments in additive manufacturing are needed to further improve the quality of 3D-printed PEEK parts, especially in terms of accuracy and bonding between adjacent layers. CLINICAL SIGNIFICANCE Additively manufactured PEEK abutments have the potential to be an alternative for implant-supported restorations in the posterior region.
Collapse
Affiliation(s)
- Almira Ada Diken Türksayar
- Department of Prosthodontics, Biruni University, Faculty of Dentistry, İstanbul, Turkey; ADMiRE Research Center, Carinthia University of Applied Sciences, Europastrasse, 9524 Villach, Austria.
| | - Sandra Petersmann
- ADMiRE Research Center, Carinthia University of Applied Sciences, Europastrasse, 9524 Villach, Austria
| | - Sebastian Spintzyk
- ADMiRE Research Center, Carinthia University of Applied Sciences, Europastrasse, 9524 Villach, Austria
| |
Collapse
|
3
|
Siqueira JRCDS, Rodriguez RMM, Campos TMB, Ramos NDC, Bottino MA, Tribst JPM. Characterization of Microstructure, Optical Properties, and Mechanical Behavior of a Temporary 3D Printing Resin: Impact of Post-Curing Time. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1496. [PMID: 38612010 PMCID: PMC11012777 DOI: 10.3390/ma17071496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 03/17/2024] [Accepted: 03/22/2024] [Indexed: 04/14/2024]
Abstract
The present study aimed to characterize the microstructure of a temporary 3D printing polymer-based composite material (Resilab Temp), evaluating its optical properties and mechanical behavior according to different post-curing times. For the analysis of the surface microstructure and establishment of the best printing pattern, samples in bar format following ISO 4049 (25 × 10 × 3 mm) were designed in CAD software (Rhinoceros 6.0), printed on a W3D printer (Wilcos), and light-cured in Anycubic Photon for different lengths of time (no post-curing, 16 min, 32 min, and 60 min). For the structural characterization, analyses were carried out using Fourier transform infrared spectroscopy (FT-IR) and scanning electron microscopy (SEM). The mechanical behavior of this polymer-based composite material was determined based on flexural strength tests and Knoop microhardness. Color and translucency analysis were performed using a spectrophotometer (VITA Easy Shade Advanced 4.0), which was then evaluated in CIELab, using gray, black, and white backgrounds. All analyses were performed immediately after making the samples and repeated after thermal aging over two thousand cycles (5-55 °C). The results obtained were statistically analyzed with a significance level of 5%. FT-IR analysis showed about a 46% degree of conversion on the surface and 37% in the center of the resin sample. The flexural strength was higher for the groups polymerized for 32 min and 1 h, while the Knoop microhardness did not show a statistical difference between the groups. Color and translucency analysis also did not show statistical differences between groups. According to all of the analyses carried out in this study, for the evaluated material, a post-polymerization time of 1 h should be suggested to improve the mechanical performance of 3D-printed devices.
Collapse
Affiliation(s)
- Joyce Roma Correia dos Santos Siqueira
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos 12245-000, Brazil; (J.R.C.d.S.S.); (R.M.M.R.); (N.d.C.R.); (M.A.B.)
| | - Rita Maria Morejon Rodriguez
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos 12245-000, Brazil; (J.R.C.d.S.S.); (R.M.M.R.); (N.d.C.R.); (M.A.B.)
| | - Tiago Moreira Bastos Campos
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru 17012-901, Brazil;
| | - Nathalia de Carvalho Ramos
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos 12245-000, Brazil; (J.R.C.d.S.S.); (R.M.M.R.); (N.d.C.R.); (M.A.B.)
| | - Marco Antonio Bottino
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos 12245-000, Brazil; (J.R.C.d.S.S.); (R.M.M.R.); (N.d.C.R.); (M.A.B.)
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit Amsterdam, 1081 LA Amsterdam, The Netherlands
| |
Collapse
|
4
|
Geiger V, Mayinger F, Hoffmann M, Reymus M, Stawarczyk B. Fracture toughness, work of fracture, flexural strength and elastic modulus of 3D-printed denture base resins in two measurement environments after artificial aging. J Mech Behav Biomed Mater 2024; 150:106234. [PMID: 37995602 DOI: 10.1016/j.jmbbm.2023.106234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 11/05/2023] [Accepted: 11/07/2023] [Indexed: 11/25/2023]
Abstract
OBJECTIVES To investigate the fracture toughness (KIC), work of fracture (WOF), flexural strength (FS) and elastic modulus (E) of four additively manufactured denture base resins in two different measurement environments after artificial aging. METHODS Rectangular specimens in two different dimensions (n = 480) were 3D-printed with four denture base resins: Denture 3D+ (DEN; NextDent), Fotodent Denture (FOT; Dreve ProDiMed), Freeprint Denture (FRE; Detax), V-Print dentbase (VPR; VOCO)). KIC, WOF, FS and E were measured after (1) water-storage (37 °C; KIC = 7 d; FS = 50 h); (2) water-storage + hydrothermal-aging (20 min, 0.2 MPa, 134 °C); (3) water storage + thermocycling (10,000 cycles, 5/55 °C) in two measurement environments (i) air-23 °C and (ii) water-37 °C. For FS, fracture types were classified, and relative frequencies determined. Univariate ANOVA, Kruskal-Wallis, Mann-Whitney U, and Spearman's correlation were calculated (p < 0.05, SPSS V.27.0). Weibull modulus (m) was calculated using the maximum likelihood estimation method. RESULTS DEN showed the highest KIC (5/6 groups), WOF and highest corresponding m (1/6 groups), while FRE presented the highest FS (2/6 groups) and E values. Hydrothermal-aging and thermocycling reduced KIC and WOF, FS and E, and the number of FS fracture pieces. For 6/8 groups, hydrothermal aging resulted in lower FS than thermocycling. Measurement in air-23 °C led to higher FS for 7/12 groups and a more brittle fracture behavior. A positive correlation between KIC and FS was observed. SIGNIFICANCE With measurements in air-23 °C resulting in higher FS than reported in water-37 °C, the measurement environment should be adapted to the clinical situation to allow valid predictions on the mechanical behavior of denture base resins when in situ.
Collapse
Affiliation(s)
- Veronika Geiger
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany.
| | - Felicitas Mayinger
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Moritz Hoffmann
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Marcel Reymus
- Department of Conservative Dentistry and Periodontology, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| |
Collapse
|
5
|
Alghazzawi TF. Relation of Crown Failure Load to Flexural Strength for Three Contemporary Dental Polymers. Polymers (Basel) 2023; 15:4312. [PMID: 37959992 PMCID: PMC10649243 DOI: 10.3390/polym15214312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 10/30/2023] [Accepted: 11/01/2023] [Indexed: 11/15/2023] Open
Abstract
Polymeric materials show great promise for use in a variety of dental applications. Manufacturers generally provide flexural strength information based on standardized (ISO and ASTM) specimen dimensions and loading conditions. It is not clear, however, if flexural strength data are predictive of the clinical performance of dental crowns. The objectives of this study were, therefore, to determine whether flexural strengths, as measured via three-point bending (3PB), would be predictive of failure loads assessed via crunch-the-crown (CTC) tests. Three brands of polymers (Trilor, Juvora, and Pekkton) were fabricated into rectangular bars and fully contoured crowns (10 specimens of each polymer brand, 30 specimens of each shape). Differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR), and burn off tests were used to characterize/confirm the materials. Bars were tested blindly in 3PB to determine flexural strength, and crowns were CTC-tested to determine failure load after luting to resin abutments. The statistical significance of the test results was evaluated via one-way ANOVA (α = 0.05) and Pearson's correlation coefficient, while regression analysis was used to test for a correlation between 3PB and CTC results. The fracture mechanisms and failure surface characteristics were characterized using scanning electron microscopy (SEM). There were significant differences (p < 0.05) in the mean crown failure loads (Trilor (7033 N) > Juvora (5217 N) > Pekkton (3023 N)) and mean flexural strengths of the bars (Trilor (468 MPa) > Juvora (197 MPa) = Pekkton (192 MPa)). The mode of crown fracture was different between the materials and included deformation (Juvora), ductile-to-brittle fracture (Pekkton), and a combination of cracks and deformation (Trilor). Flexural strengths did not correlate with the corresponding crown failure loads for any of the materials tested. These results suggest that dental practitioners should not rely on the flexural strengths reported from three-point bending tests, as advertised by the manufacturer, to predict the performance of polymeric crowns.
Collapse
Affiliation(s)
- Tariq F. Alghazzawi
- Department of Substitutive Dental Sciences, Taibah University, Madinah 42353, Saudi Arabia;
- Department of Mechanical and Materials Engineering, The University of Alabama at Birmingham, Birmingham, AL 35294, USA
| |
Collapse
|
6
|
Smith JA, Petersmann S, Arbeiter F, Schäfer U. Optimization and manufacture of polyetheretherketone patient specific cranial implants by material extrusion - A clinical perspective. J Mech Behav Biomed Mater 2023; 144:105965. [PMID: 37343357 DOI: 10.1016/j.jmbbm.2023.105965] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 06/01/2023] [Accepted: 06/06/2023] [Indexed: 06/23/2023]
Abstract
Polyetheretherketone (PEEK) is a high performing thermoplastic that has established itself as a 'gold-standard' material for cranial reconstruction. Traditionally, milled PEEK patient specific cranial implants (PSCIs) exhibit uniform levels of smoothness (excusing suture/drainage holes) to the touch (<1 μm) and homogenous coloration throughout. They also demonstrate predictable and repeatable levels of mechanical performance, as they are machined from isotropic material blocks. The combination of such factors inspires confidence from the surgeon and in turn, approval for implantation. However, manufacturing lead-times and affiliated costs to fabricate a PSCI are high. To simplify their production and reduce expenditure, hospitals are exploring the production of in-house PEEK PSCIs by material extrusion-based additive manufacturing. From a geometrical and morphological perspective, such implants have been produced with good-to-satisfactory clinical results. However, lack of clinical adoption persists. To determine the reasoning behind this, it was necessary to assess the benefits and limitations of current printed PEEK PSCIs in order to establish the status quo. Afterwards, a review on individual PEEK printing variables was performed in order to identify a combination of parameters that could enhance the aesthetics and performance of the PSCIs to that of milled implants/cranial bone. The findings from this review could be used as a baseline to help standardize the production of PEEK PSCIs by material extrusion in the hospital.
Collapse
Affiliation(s)
- James A Smith
- Research Unit Experimental Neurotraumatology, Department of Neurosurgery, Medical University of Graz, Auenbruggerplatz 2(9), 8036, Graz, Austria.
| | - Sandra Petersmann
- Materials Science and Testing of Polymers, Montanuniversitaet Leoben, Otto Gloeckel-Straße 2, 8700, Leoben, Austria
| | - Florian Arbeiter
- Materials Science and Testing of Polymers, Montanuniversitaet Leoben, Otto Gloeckel-Straße 2, 8700, Leoben, Austria
| | - Ute Schäfer
- Research Unit Experimental Neurotraumatology, Department of Neurosurgery, Medical University of Graz, Auenbruggerplatz 2(9), 8036, Graz, Austria; BioTechMed-Graz, Graz, Austria
| |
Collapse
|
7
|
de Castro EF, Nima G, Rueggeberg FA, Araújo-Neto VG, Faraoni JJ, Palma-Dibb RG, Giannini M. Effect of build orientation in gloss, roughness and color of 3D-printed resins for provisional indirect restorations. Dent Mater 2023; 39:e1-e11. [PMID: 37248138 DOI: 10.1016/j.dental.2023.05.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 04/13/2023] [Accepted: 05/02/2023] [Indexed: 05/31/2023]
Abstract
OBJECTIVES The purpose of this study was to evaluate the effect of build orientation of 3D-printed provisional resins (3DRs) on gloss (Gs), surface roughness (Sa), maximum profile valley depth (Rv), and color difference (∆E00). METHODS PMMA CAD/CAM blocks (Vita Temp/Vita) were sectioned and served as a Control. Four 3DRs (Cosmos-SLA/Yller, Cosmos-DLP/Yller, PriZma-Bioprov/Makertech, Nanolab/Wilcos) were obtained as discs (15-mm diameter, 2.5-mm thickness) in three orientations (0°, 45°, and 90°) using different 3D printers (Form 2/Formlabs, P30/Straumann, Hunter/Flashforge, W3D/Wilcos, respectively). Samples were then cleaned with isopropyl alcohol prior to post-curing in specific post-curing units. Half of the samples' surface was covered with an adhesive tape and submitted to 10,000 toothbrushing (TB) cycles. The Gs and Sa at the brushed and not brushed surfaces were evaluated with a glossmeter (Novo-curve) and a laser confocal microscope (OLS5000) (n = 10), which also obtained the Rv and 3D representative images of the interface between not brushed and brushed surfaces. Electron microscopy images of the surface of some samples was also performed (n = 3). On another set of samples (n = 5), the coordinates of luminosity and color were obtained with a spectrophotometer (Easyshade V) at baseline and after 16.7 h and 200 h of UVB aging, to calculate the ∆E00 using CIEDE:2000 formula. Additionally, 3DRs photoinitiators were identified using a minispectrometer (USB2000 +) (n = 5). Data of Gs and Sa were submitted to three-way-, Rv to two-way-, and ∆E00 to mixed-ANOVA tests, followed by Tukey's test (α = 0.05). For all variables, results from experimental groups were compared to control using Dunnett's test (α = 0.05). Student's t-test was used to compare the control at different TB cycles (Gs, Sa) or aging periods (∆E00) (α = 0.05). RESULTS Build orientation of 3DRs did not influence any of the variables studied. The 10,000 TB cycles resulted in a decrease in Gs and increase in Sa for all resins tested. The control showed higher Gs after 10,000 TB cycles than Cosmos-SLA and Nanolab resins. Compared to all 3DRs, Control presented lower ∆E00 after 200 h of UVB aging. All 3DRs presented higher ∆E00 than the clinically acceptable after 200 h of UVB aging. Lucirin® TPO was identified in all 3DRs, although PriZma might also present other photoinitiators and Nanolab might present Irgacure 369. SIGNIFICANCE Alterations in build orientation are very useful and frequently performed in the day-today of 3D-printing, thus its effect in the optical properties and in the topography of 3D-printed restorations is very relevant. For the evaluated 3D-printed provisional resins, build orientation did not influence any of the variables studied (Gs, Sa, Rv, and ∆E00), even after toothbrushing cycles and UVB aging.
Collapse
Affiliation(s)
- Eduardo F de Castro
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, Brazil.
| | - Gabriel Nima
- Department of Biomedical Sciences, Ethics, Research and Education, School of Dentistry, Universidad de Los Andes, Santiago, Chile
| | - Frederick A Rueggeberg
- Department of Restorative Sciences, Dental College of Georgia, Augusta University, Augusta, GA, USA
| | - Vitaliano G Araújo-Neto
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, Brazil
| | - Juliana J Faraoni
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Regina G Palma-Dibb
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Marcelo Giannini
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, Brazil
| |
Collapse
|
8
|
Lu WJ, Chen WC, Srimaneepong V, Chen CS, Huang CH, Lin HC, Tung OH, Huang HH. Fracture Characteristics of Commercial PEEK Dental Crowns: Combining the Effects of Aging Time and TiO 2 Content. Polymers (Basel) 2023; 15:2720. [PMID: 37376366 DOI: 10.3390/polym15122720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 06/16/2023] [Accepted: 06/16/2023] [Indexed: 06/29/2023] Open
Abstract
Polyetheretherketone (PEEK) is an emerging thermoplastic polymer with good mechanical properties and an elastic modulus similar to that of alveolar bone. PEEK dental prostheses for computer-aided design/computer-aided manufacturing (CAD/CAM) systems on the market often have additives of titanium dioxide (TiO2) to strengthen their mechanical properties. However, the effects of combining aging, simulating a long-term intraoral environment, and TiO2 content on the fracture characteristics of PEEK dental prostheses have rarely been investigated. In this study, two types of commercially available PEEK blocks, containing 20% and 30% TiO2, were used to fabricate dental crowns by CAD/CAM systems and were aged for 5 and 10 h based on the ISO 13356 specifications. The compressive fracture load values of PEEK dental crowns were measured using a universal test machine. The morphology and crystallinity of the fracture surface were analyzed by scanning electron microscopy and an X-ray diffractometer, respectively. Statistical analysis was performed using the paired t-test (α = 0.05). Results showed no significant difference in the fracture load value of the test PEEK crowns with 20% and 30% TiO2 after 5 or 10 h of aging treatment; all test PEEK crowns have satisfactory fracture properties for clinical applications. Fracture surface analysis revealed that all test crowns fractured from the lingual side of the occlusal surface, with the fracture extending along the lingual sulcus to the lingual edge, showing a feather shape at the middle part of the fracture extension path and a coral shape at the end of the fracture. Crystalline analysis showed that PEEK crowns, regardless of aging time and TiO2 content, remained predominantly PEEK matrix and rutile phase TiO2. We would conclude that adding 20% or 30% TiO2 to PEEK crowns may have been sufficient to improve the fracture properties of PEEK crowns after 5 or 10 h of aging. Aging times below 10 h may still be safe for reducing the fracture properties of TiO2-containing PEEK crowns.
Collapse
Affiliation(s)
- Wen-Ju Lu
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
| | - Wei-Cheng Chen
- Department of Medicine, MacKay Medical College, New Taipei City 252, Taiwan
- Division of Sports Medicine & Surgery, Department of Orthopedic Surgery, MacKay Memorial Hospital, Taipei 104, Taiwan
| | - Viritpon Srimaneepong
- Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok 10330, Thailand
| | - Chiang-Sang Chen
- Department of Orthopedic Surgery, Far Eastern Memorial Hospital, New Taipei City 220, Taiwan
- Department of Materials and Textiles, Asia Eastern University of Science and Technology, New Taipei City 220, Taiwan
| | - Chang-Hung Huang
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Medical Research, MacKay Memorial Hospital, Taipei 251, Taiwan
| | - Hui-Ching Lin
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Stomatology, Taipei City Hospital, Zhongxing Branch, Taipei 103, Taiwan
- General Education Center, University of Taipei, Taipei 106, Taiwan
| | - Oi-Hong Tung
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Stomatology, Taipei Veterans General Hospital, Taipei 112, Taiwan
| | - Her-Hsiung Huang
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Stomatology, Taipei Veterans General Hospital, Taipei 112, Taiwan
- Institute of Oral Biology, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Medical Research, China Medical University Hospital, China Medical University, Taichung 404, Taiwan
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 413, Taiwan
- School of Dentistry, Kaohsiung Medical University, Kaohsiung 807, Taiwan
- Department of Education and Research, Taipei City Hospital, Taipei 103, Taiwan
| |
Collapse
|
9
|
Tamașag I, Beșliu-Băncescu I, Severin TL, Dulucheanu C, Cerlincă DA. Experimental Study of In-Process Heat Treatment on the Mechanical Properties of 3D Printed Thermoplastic Polymer PLA. Polymers (Basel) 2023; 15:polym15102367. [PMID: 37242942 DOI: 10.3390/polym15102367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Revised: 05/15/2023] [Accepted: 05/17/2023] [Indexed: 05/28/2023] Open
Abstract
The scientific literature regarding additive manufacturing, mainly the material extrusion method, suggests that the mechanical characteristics of the parts obtained by this technology depend on a number of the input factors specific to the printing process, such as printing temperature, printing trajectory, layer height, etc., and also on the post-process operations for parts, which, unfortunately, requires supplementary setups, equipment, and multiple steps that raise the overall costs. Therefore, this paper aims to investigate the influence of the printing direction, the thickness of the deposited material layer, and the temperature of the previously deposited material layer on the part tensile strength, hardness by means of Shore D and Martens hardness, and surface finish by using an in-process annealing method. A Taguchi L9 DOE plan was developed for this purpose, where the test specimens, with dimensions according to ISO 527-2 type B, were analysed. The results showed that the presented in-process treatment method is possible and could lead to sustainable and cost-effective manufacturing processes. The varied input factors influenced all the studied parameters. Tensile strength tended to increase, up to 12.5%, when the in-process heat treatment was applied, showed a positive linear variation with nozzle diameter, and presented considerable variations with the printing direction. Shore D and Martens hardness had similar variations, and it could be observed that by applying the mentioned in-process heat treatment, the overall values tended to decrease. Printing direction had a negligible impact on the additively manufactured parts' hardness. At the same time, the nozzle diameter presented considerable variations, up to 36% for Martens hardness and 4% for Shore D, when higher diameter nozzles were used. The ANOVA analysis highlighted that the statistically significant factors were the nozzle diameter for the part's hardness and the printing direction for the tensile strength.
Collapse
Affiliation(s)
- Ioan Tamașag
- Faculty of Mechanical Engineering, Automotive and Robotics, Stefan cel Mare University, 720229 Suceava, Romania
| | - Irina Beșliu-Băncescu
- Faculty of Mechanical Engineering, Automotive and Robotics, Stefan cel Mare University, 720229 Suceava, Romania
| | - Traian-Lucian Severin
- Faculty of Mechanical Engineering, Automotive and Robotics, Stefan cel Mare University, 720229 Suceava, Romania
| | - Constantin Dulucheanu
- Faculty of Mechanical Engineering, Automotive and Robotics, Stefan cel Mare University, 720229 Suceava, Romania
| | - Delia-Aurora Cerlincă
- Faculty of Mechanical Engineering, Automotive and Robotics, Stefan cel Mare University, 720229 Suceava, Romania
| |
Collapse
|
10
|
Zol SM, Alauddin MS, Said Z, Mohd Ghazali MI, Hao-Ern L, Mohd Farid DA, Zahari NAH, Al-Khadim AHA, Abdul Aziz AH. Description of Poly(aryl-ether-ketone) Materials (PAEKs), Polyetheretherketone (PEEK) and Polyetherketoneketone (PEKK) for Application as a Dental Material: A Materials Science Review. Polymers (Basel) 2023; 15:polym15092170. [PMID: 37177316 PMCID: PMC10180673 DOI: 10.3390/polym15092170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 04/17/2023] [Accepted: 04/21/2023] [Indexed: 05/15/2023] Open
Abstract
Poly(aryl-ether-ketone) materials (PAEKs), a class of high-performance polymers comprised of polyetheretherketone (PEEK) and polyetherketoneketone (PEKK), have attracted interest in standard dental procedures due to their inherent characteristics in terms of mechanical and biological properties. Polyetheretherketone (PEEK) is a restorative dental material widely used for prosthetic frameworks due to its superior physical, mechanical, aesthetic, and handling features. Meanwhile, polyetherketoneketone (PEKK) is a semi-crystalline thermoplastic embraced in the additive manufacturing market. In the present review study, a new way to fabricate high-performance polymers, particularly PEEK and PEKK, is demonstrated using additive manufacturing digital dental technology, or 3-dimensional (3D) printing. The focus in this literature review will encompass an investigation of the chemical, mechanical, and biological properties of HPPs, particularly PEEK and PEKK, along with their application particularly in dentistry. High-performance polymers have gained popularity in denture prosthesis in advance dentistry due to their flexibility in terms of manufacturing and the growing interest in utilizing additive manufacturing in denture fabrication. Further, this review also explores the literature regarding the properties of high-performance polymers (HPP) compared to previous reported polymers in terms of the dental material along with the current advancement of the digital designing and manufacturing.
Collapse
Affiliation(s)
- Syazwani Mohamad Zol
- Faculty of Dentistry, Universiti Sains Islam Malaysia (USIM), Kuala Lumpur 55100, Malaysia
| | - Muhammad Syafiq Alauddin
- Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Universiti Sains Islam Malaysia (USIM), Kuala Lumpur 55100, Malaysia
| | - Zulfahmi Said
- Department of Basic Sciences and Oral Biology, Faculty of Dentistry, Universiti Sains Islam Malaysia (USIM), Kuala Lumpur 55100, Malaysia
| | - Mohd Ifwat Mohd Ghazali
- SMART RG, Faculty of Science and Technology (FST), Universiti Sains Islam Malaysia (USIM), Nilai 71800, Malaysia
| | - Lee Hao-Ern
- Faculty of Dentistry, Universiti Sains Islam Malaysia (USIM), Kuala Lumpur 55100, Malaysia
| | | | | | - Aws Hashim Ali Al-Khadim
- Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Universiti Sains Islam Malaysia (USIM), Kuala Lumpur 55100, Malaysia
| | - Azrul Hafiz Abdul Aziz
- Department of Paediatrics Dentistry and Orthodontics, Faculty of Dentistry, Universiti Sains Islam Malaysia (USIM), Kuala Lumpur 55100, Malaysia
| |
Collapse
|
11
|
Micovic Soldatovic D, Bitter M, Meinen J, Huth KC, Liebermann A, Stawarczyk B. Impact of material combinations and removal and insertion cycles on the retention force of telescopic systems. Clin Oral Investig 2023:10.1007/s00784-023-05027-w. [PMID: 37086284 DOI: 10.1007/s00784-023-05027-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Accepted: 04/16/2023] [Indexed: 04/23/2023]
Abstract
OBJECTIVES A variety of dental materials are available for the fabrication of telescopic crowns. The aim was to investigate the impact of material combinations and removal and insertion cycles on their retention forces. MATERIALS AND METHODS CAD/CAM-fabricated cobalt-chromium-molybdenum (CoCr) and zirconia (ZrO2) primary crowns were combined with polyetheretherketone (PEEK), polyetherketoneketone (PEKK), CoCr, and ZrO2 secondary crowns (four combinations included PEEK/PEKK secondary crowns in a thickness of 0.5 mm bonded to the CoCr tertiary construction), resulting in 12 different material combinations: CoCr-PEEK; CoCr-PEKK; CoCr-ZrO2; CoCr-CoCr; CoCr-PEEK 0.5; CoCr-PEKK 0.5; ZrO2-PEEK; ZrO2-PEKK; ZrO2-ZrO2, ZrO2-CoCr; ZrO2-PEEK 0.5; and ZrO2-PEKK 0.5 (n = 15 pairings per material combination). Pull-off tests were performed with a universal testing machine initially and after 500, 5000, and 10,000 removal and insertion cycles in a mastication simulator. Descriptive statistics with the Kolmogorov-Smirnov, Kruskal-Wallis, and Mann-Whitney U tests were computed (α = 0.05). RESULTS The tested parameters, material combination, and removal and insertion cycles had significant impact on the retention force values (p < 0.001). An increase in removal and insertion cycles was associated with a decrease in retention forces within CoCr and ZrO2 secondary crowns, regardless of the primary crown material. In contrast, PEEK and PEKK secondary crowns presented higher retention load values after 10,000 cycles than initially. CONCLUSION Different material combinations behaved differently after simulated removal and insertion regimens. This difference should be considered during treatment planning. CLINICAL RELEVANCE Telescopic crown systems should be made of materials with predictable retention forces that do not deteriorate with time. The implementation of new materials and technologies facilitates reproducibility and time-saving fabrication.
Collapse
Affiliation(s)
- Danka Micovic Soldatovic
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany.
| | - Maximiliane Bitter
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany
| | - John Meinen
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany
| | - Karin Christine Huth
- Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany
| | - Anja Liebermann
- Polyclinic of Prosthetic Dentistry, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Strasse 32, 50931, Cologne, Germany
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany
| |
Collapse
|
12
|
Bächle J, Merle C, Hahnel S, Rosentritt M. Bacterial Adhesion on Dental Polymers as a Function of Manufacturing Techniques. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2373. [PMID: 36984253 PMCID: PMC10054275 DOI: 10.3390/ma16062373] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/09/2023] [Accepted: 03/14/2023] [Indexed: 06/18/2023]
Abstract
The microbiological behavior of dental polymer materials is crucial to secure the clinical success of dental restorations. Here, the manufacturing process and the machining can play a decisive role. This study investigated the bacterial adhesion on dental polymers as a function of manufacturing techniques (additive/subtractive) and different polishing protocols. Specimens were made from polyaryletherketone (PEEK, PEKK, and AKP), resin-based CAD/CAM materials (composite and PMMA), and printed methacrylate (MA)-based materials. Surface roughness (Rz; Ra) was determined using a laser scanning microscope, and SFE/contact angles were measured using the sessile drop method. After salivary pellicle formation, in vitro biofilm formation was initiated by exposing the specimens to suspensions of Streptococcus mutans (S. mutans) and Streptococcus sanguinis (S. sanguinis). Adherent bacteria were quantified using a fluorometric assay. One-way ANOVA analysis found significant influences (p < 0.001) for the individual parameters (treatment and material) and their combinations for both types of bacteria. Stronger polishing led to significantly (p < 0.001) less adhesion of S. sanguinis (Pearson correlation PC = -0.240) and S. mutans (PC = -0.206). A highly significant (p = 0.010, PC = 0.135) correlation between S. sanguinis adhesion and Rz was identified. Post hoc analysis revealed significant higher bacterial adhesion for vertically printed MA specimens compared to horizontally printed specimens. Furthermore, significant higher adhesion of S. sanguinis on pressed PEEK was revealed comparing to the other manufacturing methods (milling, injection molding, and 3D printing). The milled PAEK samples showed similar bacterial adhesion. In general, the resin-based materials, composites, and PAEKs showed different bacterial adhesion. Fabrication methods were shown to play a critical role; the pressed PEEK showed the highest initial accumulations. Horizontal DLP fabrication reduced bacterial adhesion. Roughness < 10 µm or polishing appear to be essential for reducing bacterial adhesion.
Collapse
|
13
|
Tiozzo-Lyon P, Andrade M, Leiva-Sabadini C, Morales J, Olivares A, Ravasio A, Aguayo S. Microfabrication approaches for oral research and clinical dentistry. FRONTIERS IN DENTAL MEDICINE 2023. [DOI: 10.3389/fdmed.2023.1120394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/11/2023] Open
Abstract
Currently, there is a variety of laboratory tools and strategies that have been developed to investigate in-vivo processes using in-vitro models. Amongst these, microfabrication represents a disruptive technology that is currently enabling next-generation biomedical research through the development of complex laboratory approaches (e.g., microfluidics), engineering of micrometer scale sensors and actuators (micropillars for traction force microscopy), and the creation of environments mimicking cell, tissue, and organ-specific contexts. Although microfabrication has been around for some time, its application in dental and oral research is still incipient. Nevertheless, in recent years multiple lines of research have emerged that use microfabrication-based approaches for the study of oral diseases and conditions with micro- and nano-scale sensitivities. Furthermore, many investigations are aiming to develop clinically relevant microfabrication-based applications for diagnostics, screening, and oral biomaterial manufacturing. Therefore, the objective of this review is to summarize the current application of microfabrication techniques in oral sciences, both in research and clinics, and to discuss possible future applications of these technologies for in-vitro studies and practical patient care. Initially, this review provides an overview of the most employed microfabrication methods utilized in biomedicine and dentistry. Subsequently, the use of micro- and nano-fabrication approaches in relevant fields of dental research such as endodontic and periodontal regeneration, biomaterials research, dental implantology, oral pathology, and biofilms was discussed. Finally, the current and future uses of microfabrication technology for clinical dentistry and how these approaches may soon be widely available in clinics for the diagnosis, prevention, and treatment of relevant pathologies are presented.
Collapse
|
14
|
Diker E, Terzioglu H, Gouveia DNM, Donmez MB, Seidt J, Yilmaz B. Effect of material type, torque value, and sterilization on linear displacements of a scan body: An in vitro study. Clin Implant Dent Relat Res 2023; 25:419-425. [PMID: 36762614 DOI: 10.1111/cid.13187] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Revised: 12/21/2022] [Accepted: 01/23/2023] [Indexed: 02/11/2023]
Abstract
BACKGROUND There is limited knowledge on the effect of scan body (SB) material type, torque value, and sterilization on linear displacements of implant SBs. PURPOSE To evaluate the effect of material type, torque value, and sterilization on linear displacements of SBs during screw tightening by using digital image correlation (DIC) analysis. MATERIALS AND METHODS One polyetheretherketone (PEEK, Zfx Intraoral Scan Body) and one titanium SB (Ti, MPS Zimmer Scanbody R1410) were tightened with 5 Ncm torque on two implants (Zimmer TSV ⌀4.7 mm) by using a digital torque limiting device. SBs' initial spatial positions relative to the implants were recorded by using 3D DIC technique. Measurements were repeated after initially increasing torque value to 10 Ncm and then to 15 Ncm, and these steps were repeated for a total of 10 PEEK and 10 Ti SBs on both implants (n = 20). All SBs were then sterilized 25 times by using an autoclave (STATIM 5000 S G4) according to manufacturer's recommendations and all measurements were repeated. Linear displacements on three axes were calculated for each SB with increasing torque values (from 5 to 10 Ncm and from 10 to 15 Ncm) before and after sterilization. SB displacements within each torque value-sterilization pair were compared by using Mann-Whitney U test, whereas Wilcoxon signed-rank test was used to compare SB displacements within each material-torque value pair between conditions and within each material-sterilization pair between torque values (α = 0.05). RESULTS On x-axis, PEEK SBs had higher displacements than Ti SBs (p < 0.001), whereas sterilization (p ≤ 0.028) and 15 Ncm torque application (p ≤ 0.006) led to higher displacements of PEEK SBs. On y-axis, PEEK SBs had higher displacements than Ti SBs with 15 Ncm torque application (p ≤ 0.033). A total of 15 Ncm torque-applied PEEK SBs and 10 Ncm torque-applied Ti SBs had higher displacements after sterilization (p ≤ 0.028). Application of 15 Ncm torque led to higher displacements regardless of the material (p ≤ 0.002). On z-axis, PEEK SBs had higher displacements (p ≤ 0.015), except for 10 Ncm torque-applied sterilized SBs (p = 0.102). With 10 Ncm torque application, sterilization decreased the displacement values of PEEK SBs (p = 0.044). Greater displacements were observed with 10 Ncm torque-applied Ti SBs before sterilization and 15 Ncm torque-applied PEEK SBs after sterilization (p ≤ 0.033). CONCLUSIONS Axial displacement of SBs was affected by material type, torque value, and sterilization. Ti SBs mostly had lower displacements than PEEK SBs. Application of 15 Ncm torque to tested PEEK SBs should be refrained from and a calibrated tightening tool may enable the application of 10 Ncm or lower torque values for lower displacements. Sterilization generally increased PEEK SB displacements.
Collapse
Affiliation(s)
- Emre Diker
- Private Practice, Med Dis Dental Clinic, Ankara, Turkey.,Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Hakan Terzioglu
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Diogo N M Gouveia
- Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey
| | - Jeremy Seidt
- Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA.,Department of Mechanical & Aerospace Engineering, The Ohio State University College of Engineering, Columbus, Ohio, USA
| | - Burak Yilmaz
- Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA.,Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
15
|
Huang S, Wei H, Li D. Additive manufacturing technologies in the oral implant clinic: A review of current applications and progress. Front Bioeng Biotechnol 2023; 11:1100155. [PMID: 36741746 PMCID: PMC9895117 DOI: 10.3389/fbioe.2023.1100155] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 01/11/2023] [Indexed: 01/21/2023] Open
Abstract
Additive manufacturing (AM) technologies can enable the direct fabrication of customized physical objects with complex shapes, based on computer-aided design models. This technology is changing the digital manufacturing industry and has become a subject of considerable interest in digital implant dentistry. Personalized dentistry implant treatments for individual patients can be achieved through Additive manufacturing. Herein, we review the applications of Additive manufacturing technologies in oral implantology, including implant surgery, and implant and restoration products, such as surgical guides for implantation, custom titanium meshes for bone augmentation, personalized or non-personalized dental implants, custom trays, implant casts, and implant-support frameworks, among others. In addition, this review also focuses on Additive manufacturing technologies commonly used in oral implantology. Stereolithography, digital light processing, and fused deposition modeling are often used to construct surgical guides and implant casts, whereas direct metal laser sintering, selective laser melting, and electron beam melting can be applied to fabricate dental implants, personalized titanium meshes, and denture frameworks. Moreover, it is sometimes required to combine Additive manufacturing technology with milling and other cutting and finishing techniques to ensure that the product is suitable for its final application.
Collapse
Affiliation(s)
| | - Hongbo Wei
- *Correspondence: Hongbo Wei, ; Dehua Li,
| | - Dehua Li
- *Correspondence: Hongbo Wei, ; Dehua Li,
| |
Collapse
|
16
|
PEEK for Oral Applications: Recent Advances in Mechanical and Adhesive Properties. Polymers (Basel) 2023; 15:polym15020386. [PMID: 36679266 PMCID: PMC9864167 DOI: 10.3390/polym15020386] [Citation(s) in RCA: 25] [Impact Index Per Article: 25.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 01/06/2023] [Accepted: 01/07/2023] [Indexed: 01/15/2023] Open
Abstract
Polyetheretherketone (PEEK) is a thermoplastic material widely used in engineering applications due to its good biomechanical properties and high temperature stability. Compared to traditional metal and ceramic dental materials, PEEK dental implants exhibit less stress shielding, thus better matching the mechanical properties of bone. As a promising medical material, PEEK can be used as implant abutments, removable and fixed prostheses, and maxillofacial prostheses. It can be blended with materials such as fibers and ceramics to improve its mechanical strength for better clinical dental applications. Compared to conventional pressed and CAD/CAM milling fabrication, 3D-printed PEEK exhibits excellent flexural and tensile strength and parameters such as printing temperature and speed can affect its mechanical properties. However, the bioinert nature of PEEK can make adhesive bonding difficult. The bond strength can be improved by roughening or introducing functional groups on the PEEK surface by sandblasting, acid etching, plasma treatment, laser treatment, and adhesive systems. This paper provides a comprehensive overview of the research progress on the mechanical properties of PEEK for dental applications in the context of specific applications, composites, and their preparation processes. In addition, the research on the adhesive properties of PEEK over the past few years is highlighted. Thus, this review aims to build a conceptual and practical toolkit for the study of the mechanical and adhesive properties of PEEK materials. More importantly, it provides a rationale and a general new basis for the application of PEEK in the dental field.
Collapse
|
17
|
Fan D, Liu Y, Wang Y, Wang Q, Guo H, Cai Y, Song R, Wang X, Wang W. 3D printing of bone and cartilage with polymer materials. Front Pharmacol 2022; 13:1044726. [PMID: 36561347 PMCID: PMC9763290 DOI: 10.3389/fphar.2022.1044726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Accepted: 11/24/2022] [Indexed: 12/12/2022] Open
Abstract
Damage and degeneration to bone and articular cartilage are the leading causes of musculoskeletal disability. Commonly used clinical and surgical methods include autologous/allogeneic bone and cartilage transplantation, vascularized bone transplantation, autologous chondrocyte implantation, mosaicplasty, and joint replacement. 3D bio printing technology to construct implants by layer-by-layer printing of biological materials, living cells, and other biologically active substances in vitro, which is expected to replace the repair mentioned above methods. Researchers use cells and biomedical materials as discrete materials. 3D bio printing has largely solved the problem of insufficient organ donors with the ability to prepare different organs and tissue structures. This paper mainly discusses the application of polymer materials, bio printing cell selection, and its application in bone and cartilage repair.
Collapse
Affiliation(s)
- Daoyang Fan
- Department of Orthopedic, The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, China
| | - Yafei Liu
- Department of Orthopedic, The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, China
| | - Yifan Wang
- Department of Additive Manufacturing, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Qi Wang
- Department of Pediatrics, The Third Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, China
| | - Hao Guo
- Department of Orthopedic, The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, China
| | - Yiming Cai
- Department of Orthopedic, The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, China
| | - Ruipeng Song
- Department of Orthopedic, The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, China
| | - Xing Wang
- Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing, China,University of Chinese Academy of Sciences, Beijing, China,*Correspondence: Weidong Wang, ; Xing Wang,
| | - Weidong Wang
- Department of Orthopedic, The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, China,*Correspondence: Weidong Wang, ; Xing Wang,
| |
Collapse
|
18
|
Ahmad S, Hasan N, Fauziya, Gupta A, Nadaf A, Ahmad L, Aqil M, Kesharwani P. Review on 3D printing in dentistry: conventional to personalized dental care. JOURNAL OF BIOMATERIALS SCIENCE. POLYMER EDITION 2022; 33:2292-2323. [PMID: 35796720 DOI: 10.1080/09205063.2022.2099666] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
The CAD (Computer-aided design) and CAM (computer-aided manufacturing) have most applications in the manufacturing of fully automated, personalized dental devices and tailor-made treatment plans. 3D printing is one of the most rapidly expanding and new methods of manufacturing different things because of its on-demand and high productivity within the cost-effective manner which have a variety of applications in healthcare, pharmaceuticals, orthopaedics, engineered tissue models, medical devices, defence industries, automotive and aerospace sectors. Due to its emerging applications in the various sectors, the healthcare, Industries, and academic sectors are attracted towards the 3D printed materials. This review talks about the dental implants, polymers that are employed in concocting dental implants, critical parameters, and challenges which are to be considered while preparing these implants, advantages of 3D printing in the field of dentistry and the current trends. it discusses the variety of applications of 3D printed materials in the field of dentistry. Along with their method of fabrication, their critical process parameters (CPPs) are also discussed.
Collapse
Affiliation(s)
- Shadaan Ahmad
- Department of Pharmaceutics, School of Pharmaceutical Education and Research, Jamia Hamdard, New Delhi, India
| | - Nazeer Hasan
- Department of Pharmaceutics, School of Pharmaceutical Education and Research, Jamia Hamdard, New Delhi, India
| | - Fauziya
- Department of Pharmaceutics, School of Pharmaceutical Education and Research, Jamia Hamdard, New Delhi, India
| | - Akash Gupta
- Department of Pharmaceutics, School of Pharmaceutical Education and Research, Jamia Hamdard, New Delhi, India
| | - Arif Nadaf
- Department of Pharmaceutics, School of Pharmaceutical Education and Research, Jamia Hamdard, New Delhi, India
| | - Lubna Ahmad
- Department of Conservative Dentistry and Endodontics, Sudha Rustagi College of Dental Sciences & Research, Faridabad, India
| | - Mohd Aqil
- Department of Pharmaceutics, School of Pharmaceutical Education and Research, Jamia Hamdard, New Delhi, India
| | - Prashant Kesharwani
- Department of Pharmaceutics, School of Pharmaceutical Education and Research, Jamia Hamdard, New Delhi, India
| |
Collapse
|
19
|
Liu Y, Fang M, Zhao R, Liu H, Li K, Tian M, Niu L, Xie R, Bai S. Clinical Applications of Polyetheretherketone in Removable Dental Prostheses: Accuracy, Characteristics, and Performance. Polymers (Basel) 2022; 14:polym14214615. [PMID: 36365609 PMCID: PMC9654455 DOI: 10.3390/polym14214615] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/19/2022] [Accepted: 10/25/2022] [Indexed: 11/06/2022] Open
Abstract
The high-performance thermoplastic polyetheretherketone (PEEK) has excellent mechanical properties, biocompatibility, chemical stability, and radiolucency. The present article comprehensively reviews various applications of PEEK in removable dental prostheses, including in removable partial dentures (RPDs) (frameworks and clasps), double-crown RPDs, and obturators. The clinical performance of PEEK in removable dental prostheses is shown to be satisfactory and promising based on the short-term clinical evidence and technical complications are scarce. Moreover, the accuracy of RPDs is a vital factor for their long-term success rate. PEEK in removable dental prostheses is fabricated using the conventional lost-wax technique and CAD/CAM milling, which produces a good fit. Furthermore, fused deposition modeling is considered to be one of the most practical additive techniques. PEEK in removable prostheses produced by this technique exhibits good results in terms of the framework fit. However, in light of the paucity of evidence regarding other additive techniques, these manufacturers cannot yet be endorsed. Surface roughness, bacterial retention, color stability, and wear resistance should also be considered when attempting to increase the survival rates of PEEK removable prostheses. In addition, pastes represent an effective method for PEEK polishing to obtain a reduced surface roughness, which facilitates lower bacterial retention. As compared to other composite materials, PEEK is less likely to become discolored or deteriorate due to wear abrasion.
Collapse
Affiliation(s)
- Yuchen Liu
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Ming Fang
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Correspondence: (M.F.); (S.B.)
| | - Ruifeng Zhao
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Hengyan Liu
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Kangjie Li
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Min Tian
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Lina Niu
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Rui Xie
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Shizhu Bai
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Correspondence: (M.F.); (S.B.)
| |
Collapse
|
20
|
Moby V, Dupagne L, Fouquet V, Attal JP, François P, Dursun E. Mechanical Properties of Fused Deposition Modeling of Polyetheretherketone (PEEK) and Interest for Dental Restorations: A Systematic Review. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6801. [PMID: 36234139 PMCID: PMC9572506 DOI: 10.3390/ma15196801] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 09/19/2022] [Accepted: 09/26/2022] [Indexed: 06/16/2023]
Abstract
The aim of this systematic review was to determine the optimal printing parameters for the producing of fused deposition modeling (FDM) 3D-printed polyetheretherketone (PEEK) elements with mechanical properties suitable for dental restorations. Indeed, the mechanical properties are a critical prerequisite for the study of other parameters, such as physical, aesthetic and biological properties. An exhaustive electronic search was carried out in the PubMed, Embase and Web of knowledge databases to gather all the studies evaluating the influence of the printing parameters on the obtained mechanical properties of FDM 3D-printed PEEK elements were selected. Initially, the search resulted in 614 eligible papers. Independent screenings of the abstracts were performed by two authors to identify the articles related to the question. Twenty-nine studies were selected, of which eleven were further excluded after reading of the full text, and finally, eighteen articles were included in this review. The studies were difficult to compare due to the variability of the printing parameters and the types of PEEK. However, it seems interesting to use a high infill rate, a high chamber temperature close to that of the printing temperature and a heat post-treatment to obtain 3D PEEK elements presenting properties adapted to use as dental restorations. The analysis of the available literature suggested that the properties of PEEK could make it an interesting material in dental restorations to be performed with FDM additive manufacturing.
Collapse
Affiliation(s)
- Vanessa Moby
- Ingénierie Moléculaire et Physiopathologie Articulaire (IMoPA), UMR 7365 CNRS-Université de Lorraine, F-54505 Vandoeuvre-lès-Nancy, France
- CHRU Nancy, Service Odontologie, F-54000 Nancy, France
- Faculté d’Odontologie, Université de Lorraine, F-54505 Vandoeuvre-lès-Nancy, France
| | - Lucien Dupagne
- Innovative Dental Materials and Interfaces Research Unit (URB2i, UR4462), Faculty of Health, Université de Paris, 1 rue Maurice Arnoux, 92120 Montrouge, France
- Department of Prosthetic Dentistry, Louis Mourier Hospital, 178 rue des Renouillers, 92700 Colombes, France
| | - Vincent Fouquet
- Innovative Dental Materials and Interfaces Research Unit (URB2i, UR4462), Faculty of Health, Université de Paris, 1 rue Maurice Arnoux, 92120 Montrouge, France
- Department of Prosthetic Dentistry, Louis Mourier Hospital, 178 rue des Renouillers, 92700 Colombes, France
| | - Jean-Pierre Attal
- Innovative Dental Materials and Interfaces Research Unit (URB2i, UR4462), Faculty of Health, Université de Paris, 1 rue Maurice Arnoux, 92120 Montrouge, France
- Department of Dental Materials, Charles Foix Hospital, 7 Avenue de la République, 94200 Ivry-sur-Seine, France
| | - Philippe François
- Innovative Dental Materials and Interfaces Research Unit (URB2i, UR4462), Faculty of Health, Université de Paris, 1 rue Maurice Arnoux, 92120 Montrouge, France
- Department of Dental Materials, Bretonneau Hospital, 23 rue Joseph de Maistre, 75018 Paris, France
| | - Elisabeth Dursun
- Innovative Dental Materials and Interfaces Research Unit (URB2i, UR4462), Faculty of Health, Université de Paris, 1 rue Maurice Arnoux, 92120 Montrouge, France
- Department of Pediatric Dentistry, Henri Mondor Hospital, 1 rue Gustave Eiffel, 94000 Créteil, France
| |
Collapse
|
21
|
Analysis of Deep Learning Techniques for Dental Informatics: A Systematic Literature Review. Healthcare (Basel) 2022; 10:healthcare10101892. [PMID: 36292339 PMCID: PMC9602147 DOI: 10.3390/healthcare10101892] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Revised: 08/30/2022] [Accepted: 08/31/2022] [Indexed: 12/04/2022] Open
Abstract
Within the ever-growing healthcare industry, dental informatics is a burgeoning field of study. One of the major obstacles to the health care system’s transformation is obtaining knowledge and insightful data from complex, high-dimensional, and diverse sources. Modern biomedical research, for instance, has seen an increase in the use of complex, heterogeneous, poorly documented, and generally unstructured electronic health records, imaging, sensor data, and text. There were still certain restrictions even after many current techniques were used to extract more robust and useful elements from the data for analysis. New effective paradigms for building end-to-end learning models from complex data are provided by the most recent deep learning technology breakthroughs. Therefore, the current study aims to examine the most recent research on the use of deep learning techniques for dental informatics problems and recommend creating comprehensive and meaningful interpretable structures that might benefit the healthcare industry. We also draw attention to some drawbacks and the need for better technique development and provide new perspectives about this exciting new development in the field.
Collapse
|
22
|
Suganna M, Kausher H, Rownaq Ali ABM, Abed MM, Albishi WS, Al Hajji FA, Sultan NA. Knowledge on Applications of 3D Design and Printing in Dentistry Among Dental Practitioners in Saudi Arabia: A Questionnaire-Based Survey. Cureus 2022; 14:e28379. [PMID: 36171830 PMCID: PMC9508789 DOI: 10.7759/cureus.28379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2022] [Accepted: 08/24/2022] [Indexed: 11/05/2022] Open
Abstract
Background: This knowledge, attitude, and practices (KAP) survey will provide baseline data and identify gaps that may facilitate understanding and further action to plan, implement, and evaluate practice toward 3D-printing technology among dental practitioners in Saudi Arabia. Aims and objectives: The present study aims to assess dental practitioners' self-reported knowledge, attitude, and practice of 3D printing in Saudi Arabia. Methodology: A cross-sectional, closed-ended questionnaire of registered dental practitioners in Saudi Arabia was conducted. A sample size of 156 was considered for analysis. After obtaining approval from the Institutional Review Board, Riyadh Elm University, the research was conducted during the month of April 2022 amongst 154 registered dental practitioners. The research was distributed among dental health specialists either working in dental colleges, dental clinics, or both in government as well as private settings. Dentists who were not actively involved in 3D printing were excluded. SPSS software, version 25.0, (IBM Corp., Armonk, NY) was used to analyze the data. Results and conclusion: Of all dentists included in the study, 98% were found to be aware that 3D printing in dentistry is used in Saudi Arabia and 2 % were not aware of its usage in Saudi Arabia. In total, 78.60% of the dentists felt that 3D-printed implant guides made the placement of implants the most accurate and least complicated procedure, and 21.40% of the dentists felt it was the least accurate and most complicated procedure.
Collapse
|
23
|
Investigation on the Potential Use of Polypropylene Mesh for the Reinforcement of Heat-Polymerized PMMA Denture Base Resin. Polymers (Basel) 2022; 14:polym14163300. [PMID: 36015557 PMCID: PMC9414764 DOI: 10.3390/polym14163300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 08/08/2022] [Accepted: 08/10/2022] [Indexed: 11/17/2022] Open
Abstract
The aim of this study was to investigate the potential use of polypropylene (PP) hernia mesh as a reinforcement of PMMA denture base resin in comparison with metal and glass fiber meshes, with the expectation of enhancing the mechanical stability of the PMMA dentures in oral conditions. The control group with no mesh, the aluminum metal mesh (Al) group, the PP1 (PP mesh used on top) group, the PP2 (PP mesh used on both the top and bottom) group, the orthopedic casting tape with self-curing resin (DP0) group, and the flushed form (DPA) group were fabricated in a chromium mold. A total of 144 specimens were divided into three equal portions and subjected to: first, no treatment; second, thermal cycling only; and third, thermal cycling and chewing simulation. The flexural strength, maximum deformation, and flexural modulus were determined by a three-point bending test to compare mechanical properties. Fracture surfaces were evaluated by scanning electron microscopy. The obtained data were statistically analyzed by a two-way ANOVA test with Bonferroni corrections. The non-treated Al mesh reinforcement group exhibited the highest (82.66 ± 6.65 MPa) flexural strength, and the PP2 group treated with chewing simulation displayed the lowest (56.64 ± 4.59 MPa) flexural strength. The Al group showed the highest (7.25 ± 1.05 mm) maximum deformation and the PP2 group showed lowest (3.64 ± 0.28 mm) maximum deformation when both groups were not subjected to any treatment. The control group with no treatment exhibited the lowest (1556.98 ± 270.62 MPa) flexural modulus values, and the Al group with no treatment exhibited the highest (3106.07 ± 588.68 MPa) flexural modulus values. All the mesh groups displayed intact fractures. Any type of mesh used for reinforcement exhibited a significant change in all flexural properties (p < 0.001). The PP1 reinforcement group did not exhibit a significant change in mechanical properties when the effect of treatment was compared. Using PP hernia mesh on top enhanced the mechanical properties despite the weakening when it was used on both the top and bottom. The mechanical stability provided by the PP hernia mesh indicated it to be a promising candidate to be used for reinforcement.
Collapse
|
24
|
Performance of Graphene-Based and Polyether-Ether-Ketone Polymers as Removable Partial Denture Esthetic Clasp Materials after Cyclic Fatigue. Polymers (Basel) 2022; 14:polym14152987. [PMID: 35893952 PMCID: PMC9331630 DOI: 10.3390/polym14152987] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 07/19/2022] [Accepted: 07/21/2022] [Indexed: 11/17/2022] Open
Abstract
The esthetic clasp material is a clinical demand for a satisfactory removable partial denture. The purpose of this study is to assess the mechanical performance of graphene-based polymer (GBP) and polyether-ether-ketone (PEEK) materials as clasp materials. Thirty-two clasps were fabricated by CAD-CAM from two materials, GBP and PEEK. All clasps were tested for retention force after 10,000 cycles of insertion and removal and thermocycling. The clasp arms’ deformation was measured, and areas of stress−strain concentration were explored. The Mann−Whitney U test was used to compare the retentive force of the studied groups, while the independent sample t-test was applied to check the difference in clasp arm deformation at α = 0.5. The results showed a significantly higher retentive force (2.248 ± 0.315 N) in PEEK clasps, at p < 0.001. The deformation of the clasp arm of the GBP clasps was significantly higher than PEEK clasps. Areas of stress−strain concentration were seen at the junction of the retentive arm to the minor connector and at the retentive arm terminal. It could be concluded that PEEK polymer had a better mechanical performance as an esthetic clasp material than the GBP. An optimization study for GBP might be required to check the validity of such an application.
Collapse
|
25
|
Hsu WC, Peng TY, Kang CM, Chao FY, Yu JH, Chen SF. Evaluating the Effect of Different Polymer and Composite Abutments on the Color Accuracy of Multilayer Pre-Colored Zirconia Polycrystal Dental Prosthesis. Polymers (Basel) 2022; 14:polym14122325. [PMID: 35745899 PMCID: PMC9229389 DOI: 10.3390/polym14122325] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 06/03/2022] [Accepted: 06/07/2022] [Indexed: 12/25/2022] Open
Abstract
With increasing aesthetic awareness and emphasis on time costs in today’s society, monolithic multilayer precolored zirconia ceramics (M-Zr) facilitate aesthetic restorations in a convenient and straightforward manner without the need for veneering porcelain to modify the color. However, the effect of abutment materials on the final color of M-Zr remains unclear. Herein, we placed Vita A1 Shade M-Zr on six different abutment materials, zirconia (Y-TZP), 3D printed composite resin (CR), dental model resin (MR), polyetheretherketone (PEEK), polyetherketoneketone (PEKK), and cobalt−chromium alloy (Co−Cr), to evaluate their effect on the color accuracy of M-Zr. The color attributes (L*, a*, and b*) were measured using a dental spectrophotometer. The translucency parameter (TP), contrast ratio, color difference (ΔE) between each background substrate and the Vita A1 Shade Guide, and chroma values (C) were calculated to evaluate the color accuracy of M-Zr. A statistical analysis was performed using one-way analysis of variance and post hoc Tukey’s HSD tests (α = 0.05). The experimental results indicate that the TP values and contrast ratio of the M-Zr samples were 14.85 and 0.83, respectively. Co−Cr had the highest ΔE (6.08) and lowest C value (7.52); PEKK had the lowest ΔE (2.60), and PEEK had the highest C value (12.23) (p < 0.05). Notably, the ΔE values of CR (3.13), PEEK (2.86), and PEKK were within clinical indicators (ΔE < 3.7). Based on these results, it can be concluded that the abutment material has a significant effect on the final color of the M-Zr, and PEEK or PEKK resulted in good color accuracy. When choosing the dental MR, traditional zirconia, or metals as abutment materials, colored or opaque cement might be required to eliminate color distortion and achieve desirable optical properties.
Collapse
Affiliation(s)
- Wen-Chieh Hsu
- School of Dentistry, College of Dentistry, China Medical University, Taichung 40402, Taiwan;
| | - Tzu-Yu Peng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan;
| | | | - Fan-Yi Chao
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, CO 80045, USA;
| | - Jian-Hong Yu
- School of Dentistry, College of Dentistry, China Medical University, Taichung 40402, Taiwan;
- Correspondence: (J.-H.Y.); (S.-F.C.); Tel.: +886-4-2205-3366 (ext. 2309) (S.-F.C.)
| | - Su-Feng Chen
- School of Dentistry, College of Dentistry, China Medical University, Taichung 40402, Taiwan;
- Correspondence: (J.-H.Y.); (S.-F.C.); Tel.: +886-4-2205-3366 (ext. 2309) (S.-F.C.)
| |
Collapse
|
26
|
Two-body wear of occlusal splint materials from subtractive computer-aided manufacturing and three-dimensional printing. Clin Oral Investig 2022; 26:5857-5866. [PMID: 35612645 PMCID: PMC9474371 DOI: 10.1007/s00784-022-04543-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 05/06/2022] [Indexed: 11/03/2022]
Abstract
OBJECTIVES To investigate the two-body wear of occlusal splint materials fabricated from subtractive computer-aided manufacturing (CAM) compared to three-dimensional printing (3DP). MATERIAL AND METHODS Forty-eight substrates (n = 12/material) in the design of a mandibular first molar were fabricated using CAM (CAM-TD, Thermeo, pro3dure medical GmbH, Iserlohn, Germany; CAM-CL, CLEARsplint, Astron Dental Corporation, Lake Zurich, USA) and 3DP (3DP-GI, GR22 flex, pro3dure medical GmbH; 3DP-KY, KeySplint soft, Keystone Industries, Gibbstown, USA). The substrates were subjected to mastication simulation (120,000 cycles, 37 °C, 50 N, 1.3 Hz) opposed to enamel antagonists. The two-body wear was measured through matching of the scanned substrates before and after aging using Gaussian best-fit method. The damage patterns were categorized and evaluated based on microscopic examinations. Data was analyzed using Kolmogorov-Smirnov test followed by 1-way analysis of variance (ANOVA). Pearson correlation was calculated between vertical and volumetric material loss. The failure types were analyzed with Chi2-test and Ciba Geigy table. RESULTS No difference in two-body wear results between all materials was found (p = 0.102). Fatigue substrates showed a perforation for CAM and a fracture for 3DP. No abrasion losses on the antagonists were detected. CONCLUSIONS 3DP substrates showed no differences in two-body wear compared to CAM ones but are more likely to show a fracture. None of the tested materials caused an abrasion on human teeth structure. CLINICAL RELEVANCE While therapies with occlusal splint materials are rising, 3DP offers a promising alternative to CAM in terms of production accuracy and therapeutic success at reduced costs.
Collapse
|
27
|
Micovic Soldatovic D, Liebermann A, Huth KC, Stawarczyk B. Fracture load of different veneered and implant-supported 4-UNIT cantilever PEEK fixed dental prostheses. J Mech Behav Biomed Mater 2022; 129:105173. [DOI: 10.1016/j.jmbbm.2022.105173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 03/04/2022] [Accepted: 03/07/2022] [Indexed: 11/16/2022]
|
28
|
Applications and Clinical Behavior of BioHPP in Prosthetic Dentistry: A Short Review. JOURNAL OF COMPOSITES SCIENCE 2022. [DOI: 10.3390/jcs6030090] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
(1) Background: BioHPP® (Bredent, UK) is a partially crystalline poly ether ether ketone (PEEK) that is strengthened using ceramic. PEEK and its various formulations represent a very interesting alternative, and has been in-depth with its literature in recent years; (2) Methods: A PubMed and Scopus search for the term “BioHPP” yielded 73 results and 42 articles which were included in this short review. Considering the scarce literature on the subject, each article was considered in this review; (3) Results: the articles analyzed are very recent, all published in the last 5 years. Their clinical evaluation of BioHPP® highlights many positive aspects, and few articles have highlighted critical issues in its multiple clinical applications; (4) Conclusions: this material is not only extremely interesting for the future, but possesses characteristics suitable for clinical application today, for endocrowns, small adhesive bridges, temporary prostheses and for immediate loads on implant restorations. The excellent aesthetics and the possibility of simple reprocessing of the restorations made with this material invite its clinical application.
Collapse
|
29
|
Schönhoff LM, Mayinger F, Eichberger M, Reznikova E, Stawarczyk B. 3D printing of dental restorations: Mechanical properties of thermoplastic polymer materials. J Mech Behav Biomed Mater 2021; 119:104544. [PMID: 33901966 DOI: 10.1016/j.jmbbm.2021.104544] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 04/14/2021] [Accepted: 04/16/2021] [Indexed: 11/17/2022]
Abstract
In the seminal field of 3D printing of dental restorations, the time and cost saving manufacturing of removable and fixed dental prostheses from thermoplastic polymer materials employing fused filament fabrication (FFF) is gaining momentum. As of today, the additive manufacturing of the established semi-crystalline polyetheretherketone (PEEK) requires extensive post-processing and lacks precision. In this context, the amorphous polyphenylene sulfone (PPSU) may provide a higher predictability and reliability of the results. The aim of this study was to investigate the mechanical properties of PPSU and PEEK processed by FFF (PPSU1-3D (PPSU Radel) and PPSU2-3D (Ultrason P 3010 NAT)) or extrusion (PPSU1-EX (Radel R-5000 NT) and PEEK-CG (PEEK Juvora)). Three-point flexural strength, two-body wear, and Martens hardness (HM) and indentation modulus (EIT) were tested after aging. One-way ANOVA, the Kruskal-Wallis and the Pearson's and Spearman's correlation tests were computed (α = 0.05). PPSU1-3D and PPSU2-3D showed lower flexural strength values than PPSU1-EX and PEEK-CG. PPSU1-3D showed the highest, and PEEK-CG and PPSU1-EX the lowest height loss. The highest HM and EIT results were observed for PEEK-CG and the lowest for PPSU1-3D. Correlations were observed between all parameters except for the application height. In conclusion, the manufacturing process affected the flexural strength of PPSU, with 3D printed specimens presenting lower values than specimens cut from prefabricated molded material. This finding indicates that the 3D printing parameters employed for the additive manufacturing of PPSU specimens in the present investigation require further optimization. For 3D printed specimens, the quality of the filament showed an impact on the mechanical properties, underlining the importance of adhering to high quality standards during filament fabrication. Extruded PPSU led to comparable results with PEEK for flexural strength and two-body wear, indicating this novel dental restorative material to be a suitable alternative to the established PEEK for the manufacturing of both removable and fixed dental prostheses.
Collapse
Affiliation(s)
- Lisa Marie Schönhoff
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany
| | - Felicitas Mayinger
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany.
| | - Marlis Eichberger
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany
| | - Elena Reznikova
- Apium Additive Technologies GmbH, Siemensallee 84, 76187, Karlsruhe, Germany
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany
| |
Collapse
|
30
|
Basgul C, Spece H, Sharma N, Thieringer FM, Kurtz SM. Structure, properties, and bioactivity of 3D printed PAEKs for implant applications: A systematic review. J Biomed Mater Res B Appl Biomater 2021; 109:1924-1941. [PMID: 33856114 DOI: 10.1002/jbm.b.34845] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Revised: 03/09/2021] [Accepted: 03/31/2021] [Indexed: 12/14/2022]
Abstract
Additive manufacturing (AM) of high temperature polymers, specifically polyaryletherketones (PAEK), is gaining significant attention for medical implant applications. As 3D printing systems evolve toward point of care manufacturing, research on this topic continues to expand. Specific regulatory guidance is being developed for the safe management of 3D printing systems in a hospital environment. PAEK implants can benefit from many advantages of AM such as design freedom, material and antibacterial drug incorporation, and enhanced bioactivity provided by cancellous bone-like porous designs. In addition to AM PAEK bioactivity, the biomechanical strength of 3D printed implants is crucial to their performance and thus widely studied. In this review, we discuss the printing conditions that have been investigated so far for additively manufactured PAEK implant applications. The effect of processing parameters on the biomechanical strength of implants is summarized, and the bioactivity of PAEKs, along with material and drug incorporation, is also covered in detail. Finally, the therapeutic areas in which 3D printed PAEK implants are investigated and utilized are reviewed.
Collapse
Affiliation(s)
- Cemile Basgul
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA
| | - Hannah Spece
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA
| | - Neha Sharma
- Medical Additive Manufacturing Research Group, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.,Department of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, Basel, Switzerland
| | - Florian M Thieringer
- Medical Additive Manufacturing Research Group, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.,Department of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, Basel, Switzerland
| | - Steven M Kurtz
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.,Exponent, Inc, Philadelphia, Pennsylvania, USA
| |
Collapse
|
31
|
Zheng J, Kang J, Sun C, Yang C, Wang L, Li D. Effects of printing path and material components on mechanical properties of 3D-printed polyether-ether-ketone/hydroxyapatite composites. J Mech Behav Biomed Mater 2021; 118:104475. [PMID: 33773239 DOI: 10.1016/j.jmbbm.2021.104475] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 03/09/2021] [Accepted: 03/15/2021] [Indexed: 12/19/2022]
Abstract
Polyether-ether-ketone (PEEK) exhibits excellent mechanical properties and biocompatibility. Three-dimensional (3D) printing of PEEK bone substitutes has been widely used in clinical application. However, the inertness of pure PEEK hinders its integration with the surrounding bone tissue. In this study, for the first time, PEEK/hydroxyapatite (HA) composite specimens were fabricated using fused filament fabrication (FFF) technology. PEEK/HA filaments with HA contents of 0-30 wt% were fabricated via mechanical mixing and extrusion. The HA distributions inside the composite matrix and the surface morphology characteristics of the PEEK/HA composites were examined. The effects of the printing path and HA content on the mechanics of the PEEK/HA composites were systematically investigated. The results indicated that the HA particles were uniformly distributed on the composite matrix. With an increase in the HA content, the modulus of the PEEK/HA composite increased, while the strength and failure strain concomitantly decreased. When the HA content increased to 30 wt%, the tensile modulus of the composite increased by 68.6% compared with that of pure PEEK printed along the horizontal 90° path, while the tensile strength decreased by 48.2% compared with that of pure PEEK printed along the vertical 90° path. The fracture elongation of the printed specimens with different HA contents decreased in the following order: horizontal 0° > horizontal 90° > vertical 90°. The best comprehensive mechanical properties were achieved for pure PEEK fabricated along the horizontal 0° path. The results indicate that FFF technology is applicable for additive manufacturing of PEEK/HA composites with controllable compositions. Printed PEEK/HA composites have potential for applications in the design and manufacturing of personalized bone substitutes.
Collapse
Affiliation(s)
- Jibao Zheng
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China
| | | | - Changning Sun
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China
| | - Chuncheng Yang
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China
| | - Ling Wang
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China.
| | - Dichen Li
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China.
| |
Collapse
|
32
|
Tian Y, Chen C, Xu X, Wang J, Hou X, Li K, Lu X, Shi H, Lee ES, Jiang HB. A Review of 3D Printing in Dentistry: Technologies, Affecting Factors, and Applications. SCANNING 2021; 2021:9950131. [PMID: 34367410 PMCID: PMC8313360 DOI: 10.1155/2021/9950131] [Citation(s) in RCA: 123] [Impact Index Per Article: 41.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Revised: 05/20/2021] [Accepted: 06/24/2021] [Indexed: 05/14/2023]
Abstract
Three-dimensional (3D) printing technologies are advanced manufacturing technologies based on computer-aided design digital models to create personalized 3D objects automatically. They have been widely used in the industry, design, engineering, and manufacturing fields for nearly 30 years. Three-dimensional printing has many advantages in process engineering, with applications in dentistry ranging from the field of prosthodontics, oral and maxillofacial surgery, and oral implantology to orthodontics, endodontics, and periodontology. This review provides a practical and scientific overview of 3D printing technologies. First, it introduces current 3D printing technologies, including powder bed fusion, photopolymerization molding, and fused deposition modeling. Additionally, it introduces various factors affecting 3D printing metrics, such as mechanical properties and accuracy. The final section presents a summary of the clinical applications of 3D printing in dentistry, including manufacturing working models and main applications in the fields of prosthodontics, oral and maxillofacial surgery, and oral implantology. The 3D printing technologies have the advantages of high material utilization and the ability to manufacture a single complex geometry; nevertheless, they have the disadvantages of high cost and time-consuming postprocessing. The development of new materials and technologies will be the future trend of 3D printing in dentistry, and there is no denying that 3D printing will have a bright future.
Collapse
Affiliation(s)
- Yueyi Tian
- The Conversationalist Club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China
| | - ChunXu Chen
- The Conversationalist Club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China
| | - Xiaotong Xu
- The Conversationalist Club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China
| | - Jiayin Wang
- The Conversationalist Club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China
| | - Xingyu Hou
- The Conversationalist Club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China
| | - Kelun Li
- The Conversationalist Club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China
| | - Xinyue Lu
- The Conversationalist Club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China
| | - HaoYu Shi
- The Conversationalist Club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China
| | - Eui-Seok Lee
- Department of Oral and Maxillofacial Surgery, Graduate School of Clinical Dentistry, Korea University, Seoul 08308, Republic of Korea
| | - Heng Bo Jiang
- The Conversationalist Club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China
| |
Collapse
|
33
|
Retention force of polyetheretherketone and cobalt-chrome-molybdenum removable dental prosthesis clasps after artificial aging. Clin Oral Investig 2020; 25:3141-3149. [PMID: 33064206 PMCID: PMC8060199 DOI: 10.1007/s00784-020-03642-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Accepted: 10/09/2020] [Indexed: 12/26/2022]
Abstract
OBJECTIVES To examine the retention force of removable dental prosthesis (RDP) clasps made from polyetheretherketone (PEEK) and cobalt-chrome-molybdenum (CoCrMo, control group) after storage in water and artificial aging. MATERIALS AND METHODS For each material, 15 Bonwill clasps with retentive buccal and reciprocal lingual arms situated between the second pre- and first molar were manufactured by milling (Dentokeep [PEEKmilled1], NT digital implant technology; breCAM BioHPP Blank [PEEKmilled2], bredent), pressing (BioHPP Granulat for 2 press [PEEKpressed], bredent), or casting (remanium GM 800+ [CoCrMo], Dentaurum); N = 60, n = 15/subgroup. A total of 50 retention force measurements were performed for each specimen per aging level (initial; after storage [30 days, 37 °C] and 10,000 thermal cycles; after storage [60 days, 37 °C] and 20,000 thermal cycles) in a pull-off test. Data were statistically analyzed using one-way ANOVA, post hoc Scheffé and mixed models (p < 0.05). RESULTS Initial, PEEKpressed (80.2 ± 35.2) and PEEKmilled1 (98.9 ± 40.3) presented the lowest results, while PEEKmilled2 (170.2 ± 51.8) showed the highest values. After artificial aging, the highest retention force was observed for the control group (131.4 ± 56.8). The influence of artificial aging was significantly higher for PEEK-based materials. While PEEKmilled2 and PEEKpressed showed an initial decline in retention force, all other groups presented no impact or an increase in retention force over a repetitive insertion and removal of the clasps. CONCLUSIONS Within the tested PEEK materials, PEEKmilled2 presented superior results than PEEKpressed. Although CoCrMo showed higher values after artificial aging, all materials exhibited sufficient retention to recommend usage under clinical conditions. CLINICAL RELEVANCE As RDPs are still employed for a wide range of indications, esthetic alternatives to conventional CoCrMo clasps are sought.
Collapse
|
34
|
Raj DA, Chander NG, Reddy JR, Balasubramaniam M. Clinical acceptability of PEEK fixed dental prosthesis in partially edentulous patient - A one year single arm pilot study. J Oral Biol Craniofac Res 2020; 10:523-528. [PMID: 32874882 DOI: 10.1016/j.jobcr.2020.08.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Revised: 08/06/2020] [Accepted: 08/06/2020] [Indexed: 11/27/2022] Open
Abstract
Purpose The study evaluated the clinical efficacy of Polyether ether ketone (PEEK) fixed dental prosthesis (FDP) over a period of one year using modified Ryges criteria and California Dental Assessment system. Methods The group consisted of 20 patients restored with posterior three-unit PEEK FDP. Patient recall and clinical examination of the restorations were done at interval of 0, 3, 6, 9 and 12 months. Clinical examination for evaluation of longevity of restorations was done using modified Ryges criteria and California dental assessment system on chipping of the veneered composite, discoloration at the marginal areas, and marginal adaptation, retention, periodontal health and hygiene of PEEK FDP. Radiographic assessment was done after 12 months. Statistical analysis were done using Friedman test. Results 95% of the patients had maintained the restoration of PEEK FDP without fracture during the study period. 5% patient reported with de-cementation of fixed dental prosthesis. 10% of the PEEK FDP shows marginal discoloration. However, no significant changes were observed during the periodic time interval evaluation in marginal adaptation, oral hygiene status and periodontal health. (p < 0.5). Conclusion PEEK FDP had satisfactory clinical efficacy and acceptable clinical outcome during the observation period of 12 months. No significant radiological changes were observed at the end of 12 months.
Collapse
Affiliation(s)
- D Arun Raj
- Department of Prosthodontics, Sri Ramaswami Memorial Dental College, Ramapuram, India
| | - Naveen Gopi Chander
- Department of Prosthodontics, Sri Ramaswami Memorial Dental College, Ramapuram, India
| | - Jetti Ramesh Reddy
- Department of Prosthodontics, Sri Ramaswami Memorial Dental College, Ramapuram, India
| | | |
Collapse
|