1
|
Singh AK, Singh S, Minocha T, Yadav SK, Narayan R, Nayak UY, Singh SK, Awasthi R. In vitro profiling and molecular dynamics simulation studies of berberine loaded MCM-41 mesoporous silica nanoparticles to prevent neuronal apoptosis. NANOSCALE ADVANCES 2024; 6:2469-2486. [PMID: 38694466 PMCID: PMC11059486 DOI: 10.1039/d3na01142a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Accepted: 03/27/2024] [Indexed: 05/04/2024]
Abstract
Neuronal loss in Alzheimer's disease has been reported to display features of apoptosis, pyroptosis (programmed necrosis), or necroptosis. This study thoroughly examines the production and characterization of MCM-41 based berberine (BBR)-loaded porous silica nanoparticles (MSNs) by a modified Stöber method, focusing on their possible role in inhibiting the apoptotic process. Particle size, polydispersity index, morphology, drug loading, zeta potential, entrapment efficiency, and drug release were examined. The formulation was analyzed using various spectroscopic techniques. The surface area was computed by the Brunauer-Emmett-Teller plot. Computational models were developed for molecular dynamics simulation studies. A small PDI value indicated an even distribution of particles at nanoscale sizes (80-100 nm). Results from XRD and SEAD experiments confirmed the amorphous nature of BBR in nanoparticles. Nanoparticles had high entrapment (75.21 ± 1.55%) and drug loading (28.16 ± 2.5%) efficiencies. A negative zeta potential value (-36.861.1 mV) indicates the presence of silanol groups on the surface of silica. AFM findings reveal bumps due to the surface drug that contributed to the improved roughness of the MSNs-BBR surface. Thermal gravimetric analysis confirmed the presence of BBR in MSNs. Drug release was controlled by simple diffusion or quasi-diffusion. Molecular dynamics simulations confirmed the existence of diffused drug molecules. Cellular studies using SH-SY-5Y cells revealed dose-dependent growth inhibition. Fragmented cell nuclei and nuclear apoptotic bodies in DAPI-stained cells exposed to nanoparticles showed an increase in apoptotic cells. Flow cytometry analysis demonstrated a lower red-to-green ratio in SH-SY-5Y cells treated with nanoparticles. This suggests improved mitochondrial health, cellular viability restoration, and prevention of the apoptotic process. This study provides essential data on the synthesis and potential of MSNs loaded with BBR, which may serve as a viable therapeutic intervention for conditions associated with apoptosis.
Collapse
Affiliation(s)
- Anurag Kumar Singh
- Centre of Experimental Medicine & Surgery, Institute of Medical Sciences, Banaras Hindu University Varanasi 221005 Uttar Pradesh India +91-9415389046
| | - Snigdha Singh
- Centre of Experimental Medicine & Surgery, Institute of Medical Sciences, Banaras Hindu University Varanasi 221005 Uttar Pradesh India +91-9415389046
| | - Tarun Minocha
- Department of Zoology, Institute of Science, Banaras Hindu University Varanasi 221005 India
| | - Sanjeev Kumar Yadav
- Department of Zoology, Institute of Science, Banaras Hindu University Varanasi 221005 India
| | - Reema Narayan
- Department of Pharmaceutics, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education Manipal 576104 Karnataka India
| | - Usha Yogendra Nayak
- Department of Pharmaceutics, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education Manipal 576104 Karnataka India
| | - Santosh Kumar Singh
- Centre of Experimental Medicine & Surgery, Institute of Medical Sciences, Banaras Hindu University Varanasi 221005 Uttar Pradesh India +91-9415389046
| | - Rajendra Awasthi
- Department of Pharmaceutical Sciences, School of Health Sciences & Technology, UPES University Dehradun 248007 Uttarakhand India +91-9495234530
| |
Collapse
|
2
|
Müller-Renno C, Ziegler C. The Contribution of Scanning Force Microscopy on Dental Research: A Narrative Review. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2100. [PMID: 38730904 PMCID: PMC11084532 DOI: 10.3390/ma17092100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Revised: 04/23/2024] [Accepted: 04/24/2024] [Indexed: 05/13/2024]
Abstract
Scanning force microscopy (SFM) is one of the most widely used techniques in biomaterials research. In addition to imaging the materials of interest, SFM enables the mapping of mechanical properties and biological responses with sub-nanometer resolution and piconewton sensitivity. This review aims to give an overview of using the scanning force microscope (SFM) for investigations on dental materials. In particular, SFM-derived methods such as force-distance curves (scanning force spectroscopy), lateral force spectroscopy, and applications of the FluidFM® will be presented. In addition to the properties of dental materials, this paper reports the development of the pellicle by the interaction of biopolymers such as proteins and polysaccharides, as well as the interaction of bacteria with dental materials.
Collapse
Affiliation(s)
- Christine Müller-Renno
- Department of Physics and Research Center OPTIMAS, RPTU Kaiserslautern, 67663 Kaiserslautern, Germany;
| | | |
Collapse
|
3
|
Ozer NE, Sahin Z, Yikici C, Duyan S, Kilicarslan MA. Bacterial adhesion to composite resins produced by additive and subtractive manufacturing. Odontology 2024; 112:460-471. [PMID: 37819468 DOI: 10.1007/s10266-023-00862-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 09/26/2023] [Indexed: 10/13/2023]
Abstract
The aim of this study was to evaluate the surface roughness and contact angle of composite resins produced by CAD/CAM milling and three-dimensional (3D) printing for permanent restorations as well as the adhesion of S. mutans and S. sanguinis bacteria to these composites. Three CAD/CAM milling composite resins (Vita Enamic-VE, Cerasmart-CE, Lava Ultimate-LU) and three 3D printing resins (Varseo Smile Crown plus-VSC, Saremco print Crowntech-SPC, Formlabs 3B Permanent crown-FLP) were selected. Twenty samples were prepared for each group. Using a contact profilometer, the surface roughness was determined, and an optical goniometer was used to quantify the contact angle. To evaluate the bacterial adhesion, composite specimens were immersed in mucin containing artificial saliva. All samples were incubated for 24 h at 37°C in 5% CO2. CFUs were determined by counting colonies after the incubation period. Surface roughness values of test samples were the highest in the Group VSC [0.46 (0.14) µm], whereas the lowest values were found in the Group LU [0.23 (0.05) µm]. There was no statistically significant difference between the groups in contact angle values (p > 0.05). The S. mutans adhesion extent on the Group SPC was statistically higher compared to all other materials with p < 0.05. For S. sanguinis, the lowest bacterial adhesion value was recorded in Group CE (3.00 × 104 CFU/ml) and statistically significant differences were found with Group VE and VSC (p < 0.05). Different digital manufacturing techniques and material compositions can affect the surface roughnesses of composite resins. All composite resin samples have hydrophobic characteristics. Microbial adhesion of the tested composite resins may be varied depending on the bacterial species. S. mutans showed much more adhesion to these materials than S. sanguinis.
Collapse
Affiliation(s)
- Nazire Esra Ozer
- Department of Prosthodontics, Faculty of Dentistry, Lokman Hekim University, Söğütözü. 2179 St., 06510, Çankaya, Ankara, Turkey.
| | - Zeynep Sahin
- Department of Prosthodontics, Faculty of Dentistry, Lokman Hekim University, Söğütözü. 2179 St., 06510, Çankaya, Ankara, Turkey
| | - Cansu Yikici
- Department of Restorative Dentistry, Faculty of Dentistry, Lokman Hekim University, Çankaya, Ankara, Turkey
| | - Serhat Duyan
- Department of Medical Microbiology, Department of Microbiology, University of Health Sciences, Gülhane Training and Research Hospital, Etlik, Ankara, Turkey
| | - Mehmet Ali Kilicarslan
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Yenimahalle, Ankara, Turkey
| |
Collapse
|
4
|
Saláta J, Szabó F, Csuti P, Antal M, Márton P, Hermann P, Borbély J, Ábrám E. Effect of thickness, translucency, and substrates on the masking ability of a polymer-infiltrated ceramic-network material. J ESTHET RESTOR DENT 2023; 35:886-895. [PMID: 37335072 DOI: 10.1111/jerd.13071] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 05/23/2023] [Accepted: 06/03/2023] [Indexed: 06/21/2023]
Abstract
OBJECTIVE The aim of this in vitro study is to evaluate the masking ability of polymer-infiltrated ceramic-network materials (PICN) with different translucencies and thicknesses on multiple types of substrates. MATERIALS AND METHODS Ceramic samples were prepared of VITA ENAMIC blocks in two different translucencies (2M2-T, 2M2-HT) in a thickness range of 0.5-2.5 mm (±0.05 mm). Layered specimens were obtained using composite substrates in nine shades and transparent try-in paste. Spectral reflectance of specimens was measured using a Konica Minolta CM-3720d spectrophotometer and D65 standard illumination. CIEDE2000 color difference (ΔE00 ) between two samples was evaluated using 50%:50% perceptibility and acceptability thresholds. Specular component of the reflection was examined with Specular Component Excluded (SCE) and Included (SCI) settings. Statistical evaluation was performed by linear regression analysis, Kruskal-Wallis test, and multiplicative effect analysis. RESULTS An increase in thickness of 0.5 mm reduces ΔE00 of HT samples to 73.5%, of T samples to 60.5% (p < 0.0001). Five substrates with HT specimens, and three substrates with T specimens had significantly different results from average (p < 0.05). There is a significant difference between SCE and SCI data depending on the wavelength (p < 0.0001). CONCLUSIONS Masking ability of PICN materials is influenced by the thickness and translucency of the ceramic, and by the substrate. Reflection of the examined PICN material is characterized by both diffuse and specular reflection. CLINICAL SIGNIFICANCE Although PICN materials have been available on the market for 10 years now, there is a lack of information regarding their masking ability. Acquiring in-depth data and thereby practical experience of the factors affecting the esthetics of PICN materials is essential for creating perfectly lifelike restorations.
Collapse
Affiliation(s)
- József Saláta
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
- Károly Rácz Doctoral School of Clinical Medicine, Semmelweis University, Budapest, Hungary
| | - Ferenc Szabó
- LightingLab, Calibration Laboratory Ltd, Veszprém, Hungary
| | - Péter Csuti
- LightingLab, Calibration Laboratory Ltd, Veszprém, Hungary
| | - Melinda Antal
- Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Péter Márton
- Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Péter Hermann
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Judit Borbély
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Emese Ábrám
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| |
Collapse
|
5
|
Lukomska-Szymanska M, Radwanski M, Kharouf N, Mancino D, Tassery H, Caporossi C, Inchingolo F, de Almeida Neves A, Chou YF, Sauro S. Evaluation of Physical-Chemical Properties of Contemporary CAD/CAM Materials with Chromatic Transition "Multicolor". MATERIALS (BASEL, SWITZERLAND) 2023; 16:4189. [PMID: 37297323 PMCID: PMC10254467 DOI: 10.3390/ma16114189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 05/31/2023] [Accepted: 06/03/2023] [Indexed: 06/12/2023]
Abstract
The use of materials for computer-aided design/computer-aided manufacturing (CAD/CAM) has been rapidly increasing in daily practice. However, one of the main issues regarding modern CAD/CAM materials is their aging in the oral environment, which may lead to significant changes in their overall properties. The aim of this study was to compare the flexural strength, water sorption, cross-link density (softening ratio%), surface roughness, and SEM analysis of three modern CAD/CAM "multicolor" composites. Grandio (Grandio disc multicolor-VOCO GmbH, Cuxhaven, Germany), Shofu (Shofu Block HC-Shofu Inc., Kyoto, Japan), and Vita (Vita Enamic multiColor-Vita Zahnfabrik, Bad Sackingen, Germany) were tested in this study. They were prepared in stick-shaped specimens and submitted to different tests after several aging protocols, such as thermocycling and mechanical cycle loading challenge. Further disc-shaped specimens were also created and tested for water sorption, cross-link density, surface roughness, and SEM ultramorphology, before and after storage in an ethanol-based solution. For flexural strength and ultimate tensile strength, Grandio showed the greatest values both at baseline and after aging (p < 0.05). Grandio and Vita Enamic presented the highest modulus of elasticity and the lowest water sorption (p < 0.05). A significant reduction (p < 0.05) in microhardness after ethanol storage (softening ratio%) was observed especially in Shofu. Grandio had the lowest roughness parameters compared to the other tested CAD/CAM materials, while ethanol storage significantly increased the Ra and RSm values in Shofu (p < 0.05). Despite the comparable modulus of elasticity of Vita and Grandio, this latter showed greater flexural strength and ultimate tensile strength both at baseline and after aging. Hence, Grandio and Vita Enamic may be employed for the anterior teeth and for those restorations requiring load-bearing capacity. Conversely, aging seems to affect several properties of Shofu, so its use for permanent restorations should be well-pondered based on the clinical situation.
Collapse
Affiliation(s)
| | - Mateusz Radwanski
- Department of Endodontics, Medical University of Lodz, 251 Pomorska Str., 92-213 Lodz, Poland;
| | - Naji Kharouf
- Department of Endodontics and Conservative Dentistry, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France; (N.K.)
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Strasbourg University, 67000 Strasbourg, France
| | - Davide Mancino
- Department of Endodontics and Conservative Dentistry, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France; (N.K.)
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Strasbourg University, 67000 Strasbourg, France
| | - Herve Tassery
- Ecole de Médecine Dentaire de Marseille, Université d’Aix-Marseille, 13385 Marseille, France
- Laboratoire Bioinginierie et Nanoscience, LBN, Université de Montpellier, 545 Pr JL Viala, 34090 Montpellier, France
| | | | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy
| | - Aline de Almeida Neves
- Department of Pediatric Dentistry and Orthodontics, Universidade Federal do Rio de Janeiro, Rio de Janeiro 21941-853, Brazil
| | - Yu Fu Chou
- Dental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Ciencias de la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo s/n, Alfara del Patriarca, 46115 Valencia, Spain
| | - Salvatore Sauro
- Independent Researcher, Roma, 65B, 00030 Labico, Italy
- Dental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Ciencias de la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo s/n, Alfara del Patriarca, 46115 Valencia, Spain
| |
Collapse
|
6
|
Roscoe MG, McSweeney J, Addison O. Pre-cementation treatment of glass-ceramics with vacuum impregnated resin coatings. Dent Mater 2023; 39:492-496. [PMID: 36997430 DOI: 10.1016/j.dental.2023.02.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 02/27/2023] [Indexed: 03/30/2023]
Abstract
OBJECTIVE The study aimed to investigate the effectiveness of a vacuum impregnation process to eliminate the porosity at the ceramic-resin interface to optimize the reinforcement of a glass-ceramic by resin cementation. METHODS 100 leucite glass-ceramic disks (1.0 ± 0.1 mm thickness) were air-abraded, etched with 9.6 % HF acid, and silanated. Specimens were randomly allocated to 5 groups (n = 20). Group A received no further treatment (uncoated control). Groups B and D were resin-coated under atmospheric pressure, whereas groups C and E were resin-coated using vacuum impregnation. The polymerized resin-coating surfaces of specimens in groups B and C were polished to achieve a resin thickness of 100 ± 10 µm, while in groups D and E no resin-coating modification was performed prior to bi-axial flexure strength (BFS) determination. Optical microscopy was undertaken on the fracture fragments to identify the failure mode and origin. Comparisons of BFS group means were made by a one-way analysis of variance (ANOVA) and post-hoc Tukey test at α = 0.05. RESULTS All resin-coated sample groups (B-E) showed a statistically significant increase in mean BFS compared with the uncoated control (p < 0.01). There was a significant difference in BFS between the ambient and vacuum impregnated unpolished groups (D and E) (p < 0.01), with the greatest strengthening achieved using a vacuum impregnation technique. SIGNIFICANCE Results highlight the opportunity to further develop processes to apply thin conformal resin coatings, applied as a pre-cementation step to strengthen dental glass-ceramics.
Collapse
Affiliation(s)
- Marina Guimarães Roscoe
- Faculty of Dentistry, Oral and Craniofacial Sciences, King's College London, London, UK; Faculty of Dentistry, Department of Biomaterials and Oral Biology, University of Sao Paulo, Sao Paulo, Brazil.
| | - Jack McSweeney
- Faculty of Dentistry, Oral and Craniofacial Sciences, King's College London, London, UK
| | - Owen Addison
- Faculty of Dentistry, Oral and Craniofacial Sciences, King's College London, London, UK
| |
Collapse
|
7
|
Sandmair MN, Kleber C, Ströbele DA, von See C. AFM Analysis of a Three-Point Flexure Tested, 3D Printing Definitive Restoration Material for Dentistry. J Funct Biomater 2023; 14:jfb14030152. [PMID: 36976076 PMCID: PMC10056548 DOI: 10.3390/jfb14030152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 02/28/2023] [Accepted: 03/07/2023] [Indexed: 03/12/2023] Open
Abstract
Background: Three-dimensional printing is a rapidly developing technology across all industries. In medicine recent developments include 3D bioprinting, personalized medication and custom prosthetics and implants. To ensure safety and long-term usability in a clinical setting, it is essential to understand material specific properties. This study aims to analyze possible surface changes of a commercially available and approved DLP 3D printed definitive restoration material for dentistry after three-point flexure testing. Furthermore, this study explores whether Atomic Force Microscopy (AFM) is a feasible method for examination of 3D printed dental materials in general. This is a pilot study, as there are currently no studies that analyze 3D printed dental materials using an AFM. Methods: The present study consisted of a pretest followed by the main test. The resulting break force of the preliminary test was used to determine the force used in the main test. The main test consisted of atomic force microscopy (AFM) surface analysis of the test specimen followed by a three-point flexure procedure. After bending, the same specimen was analyzed with the AFM again, to observe possible surface changes. Results: The mean root mean square (RMS) roughness of the segments with the most stress was 20.27 nm (±5.16) before bending, while it was 26.48 nm (±6.67) afterward. The corresponding mean roughness (Ra) values were 16.05 nm (±4.25) and 21.19 nm (±5.71) Conclusions: Under three-point flexure testing, the surface roughness increased significantly. The p-value for RMS roughness was p = 0.003, while it was p = 0.006 for Ra. Furthermore, this study showed that AFM surface analysis is a suitable procedure to investigate surface changes in 3D printed dental materials.
Collapse
Affiliation(s)
- Maximilian N. Sandmair
- Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, 3500 Krems, Austria
- Correspondence: (M.N.S.); (C.v.S.)
| | - Christoph Kleber
- Department of Medicine, Faculty of Medicine and Dentistry, Danube Private University, 3500 Krems, Austria
| | - Dragan A. Ströbele
- Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, 3500 Krems, Austria
| | - Constantin von See
- Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, 3500 Krems, Austria
- Correspondence: (M.N.S.); (C.v.S.)
| |
Collapse
|
8
|
Kim W, Yoon DK. Electron microscopy analysis of soft materials with
freeze‐fracture
techniques. B KOREAN CHEM SOC 2022. [DOI: 10.1002/bkcs.12647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Wantae Kim
- Department of Chemistry Korea Advanced Institute of Science and Technology (KAIST) Daejeon Republic of Korea
| | - Dong Ki Yoon
- Department of Chemistry Korea Advanced Institute of Science and Technology (KAIST) Daejeon Republic of Korea
- KAIST Institute for Nanocentry Korea Advanced Institute of Science and Technology (KAIST) Daejeon Republic of Korea
| |
Collapse
|
9
|
Effect of Sintering and Infiltration Conditions on Nanoscale Dual Network SiO 2/Polymethyl Metacrylate Composites Mimicking Human Enamel. J Dent 2022; 126:104311. [PMID: 36170898 DOI: 10.1016/j.jdent.2022.104311] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 09/21/2022] [Accepted: 09/24/2022] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE The aim of this study was to achieve facile sintering conditions and rapid penetration of organic substances into the structure of sintered silica network on the nano-scale in order to prepare polymer infiltrated ceramic network mimicking human enamel. METHODS Stepwise temperature programming (stepwise isothermal firing) was used to create a cohesive ceramic network containing interconnected pores, which is essential to provide polymer/ceramic dual networks. Liquid phase self-penetration, ultrasonic irradiation assisted liquid phase penetration and vapor phase penetration routes were used to infiltrate methyl methacrylate monomers and benzoyl peroxide reagent into the porous silica blocks. RESULTS The use of stepwise isothermal firing route, in comparison with high temperature sintering methods, significantly reduces the time and temperature required for the preliminary preparation of the SiO2 samples and reaching the appropriate interconnected porous structure. The most appropriate method for monomer and oxidant reagents infiltration is to use liquid phase infiltration assisted by ultrasound irradiation of pre-sintered nano-silica blocks. It was found that the amount of infiltrated monomer and oxidizing agent, degree of conversion of the monomer to the polymer and surface hardness of the samples strongly depend on the infiltration route. CLINICAL SIGNIFICANCE The use of inexpensive silica nanoparticles and low temperature sintering and the use of ultrasound waves to quickly and effectively penetrate methyl methacrylate monomers and increase the polymerization efficiency lead to the preparation of composites with a transparent appearance and mechanical properties similar to human tooth enamel.
Collapse
|