1
|
Richardson KM, Jospe MR, Bohlen LC, Crawshaw J, Saleh AA, Schembre SM. The efficacy of using continuous glucose monitoring as a behaviour change tool in populations with and without diabetes: a systematic review and meta-analysis of randomised controlled trials. Int J Behav Nutr Phys Act 2024; 21:145. [PMID: 39716288 DOI: 10.1186/s12966-024-01692-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2024] [Accepted: 12/09/2024] [Indexed: 12/25/2024] Open
Abstract
BACKGROUND Continuous glucose monitoring (CGM) holds potential as a precision public health intervention, offering personalised insights into how diet and physical activity affect glucose levels. Nevertheless, the efficacy of using CGM in populations with and without diabetes to support behaviour change and behaviour-driven outcomes remains unclear. This systematic review and meta-analysis examines whether using CGM-based feedback to support behaviour change affects glycaemic, anthropometric, and behavioural outcomes in adults with and without diabetes. METHODS Ovid MEDLINE, Cochrane Central Register of Controlled Trials, Elsevier Embase, EBSCOhost PsycINFO, and ProQuest Dissertations & Theses Global were searched through January 2024. Eligible studies were randomised controlled trials in adults that implemented CGM-based feedback in at least one study arm compared to a control without CGM feedback. Dual screening, data extraction, and bias assessment were conducted independently. Mean differences in outcomes between intervention and comparison groups were analysed using generic inverse variance models and random effects. Robustness of pooled estimates from random-effects models was considered with sensitivity and subgroup analyses. RESULTS Twenty-five clinical trials with 2996 participants were included. Most studies were conducted in adults with type 2 diabetes (n = 17/25; 68%), followed by type 1 diabetes (n = 3/25, 12%), gestational diabetes (n = 3/25, 12%), and obesity (n = 3/25, 12%). Eleven (44%) studies reported CGM-affiliated conflicts of interest. Interventions incorporating CGM-based feedback reduced HbA1c by 0.28% (95% CI 0.15, 0.42, p < 0.001; I2 = 88%), and increased time in range by 7.4% (95% CI 2.0, 12.8, p < 0.008; I2 = 80.5%) compared to arms without CGM, with non-significant effects on time above range, BMI, and weight. Sensitivity analyses showed consistent mean differences in HbA1c across different conditions, and differences between subgroups were non-significant. Only 4/25 studies evaluated the effect of CGM on dietary changes; 5/25 evaluated physical activity. CONCLUSIONS This evidence synthesis found favourable, though modest, effects of CGM-based feedback on glycaemic control in adults with and without diabetes. Further research is needed to establish the behaviours and behavioural mechanisms driving the observed effects across diverse populations. TRIAL REGISTRATION CRD42024514135.
Collapse
Affiliation(s)
- Kelli M Richardson
- School of Nutritional Sciences and Wellness, College of Agriculture, Life and Environmental Sciences, University of Arizona, Tucson, AZ, USA
| | - Michelle R Jospe
- Department of Oncology, Lombardi Comprehensive Cancer Center, Georgetown University, 2115 Wisconsin Avenue NW Suite 300, Washington, D.C, 20007, USA
| | - Lauren C Bohlen
- Center for Health Promotion and Health Equity, Department of Behavioural and Social Sciences, Brown University School of Public Health, Providence, RI, USA
| | - Jacob Crawshaw
- Centre for Implementation Research, Ottawa Hospital Research Institute, Ottawa, ON, Canada
| | - Ahlam A Saleh
- Arizona Health Sciences Library, University of Arizona, Tucson, AZ, USA
| | - Susan M Schembre
- Department of Oncology, Lombardi Comprehensive Cancer Center, Georgetown University, 2115 Wisconsin Avenue NW Suite 300, Washington, D.C, 20007, USA.
| |
Collapse
|
2
|
Lever CS, Williman JA, Boucsein A, Watson A, Sampson RS, Sergel-Stringer OT, Keesing C, Chepulis L, Wheeler BJ, de Bock MI, Paul RG. Real time continuous glucose monitoring in high-risk people with insulin-requiring type 2 diabetes: A randomised controlled trial. Diabet Med 2024; 41:e15348. [PMID: 38758653 DOI: 10.1111/dme.15348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 04/29/2024] [Accepted: 04/30/2024] [Indexed: 05/19/2024]
Abstract
AIMS To investigate the impact of real-time continuous glucose monitoring (rtCGM) on glycaemia in a predominantly indigenous (Māori) population of adults with insulin-requiring type 2 diabetes (T2D) in New Zealand. METHODS Twelve-week, multicentre randomised controlled trial (RCT) of adults with T2D using ≥0.2 units/kg/day of insulin and elevated glycated haemoglobin (HbA1c) ≥64 mmol/mol (8.0%). Following a 2-week blinded CGM run-in phase, participants were randomised to rtCGM or control (self-monitoring blood glucose [SMBG]). The primary outcome was time in the target glucose range (3.9-10 mmol/L; TIR) during weeks 10-12, with data collected by blinded rtCGM in the control group. RESULTS Sixty-seven participants entered the RCT phase (54% Māori, 57% female), median age 53 (range 16-70 years), HbA1c 85 (IQR 74, 94) mmol/mol (9.9 [IQR 8.9, 10.8]%), body mass index (36.7 ± 7.7 kg/m2). Mean (±SD) TIR increased from 37 (24)% to 53 (24)% [Δ 13%; 95% CI 4.2 to 22; P = 0.007] in the rtCGM group but did not change in the SMBG group [45 (21)% to 45 (25)%, Δ 2.5%, 95% CI -6.1 to 11, P = 0.84]. Baseline-adjusted between-group difference in TIR was 10.4% [95% CI -0.9 to 21.7; P = 0.070]. Mean HbA1c (±SD) decreased in both groups from 85 (18) mmol/mol (10.0 [1.7]%) to 64 (16) mmol/mol (8.0 [1.4]%) in the rtCGM arm and from 81 (12) mmol/mol (9.6 [1.1]%) to 65 (13) mmol/mol (8.1 [1.2]%) in the SMBG arm (P < 0.001 for both). There were no severe hypoglycaemic or ketoacidosis events in either group. CONCLUSIONS Real-time CGM use in a supportive treat-to-target model of care likely improves glycaemia in a population with insulin-treated T2D and elevated HbA1c.
Collapse
Affiliation(s)
- Claire S Lever
- Te Huataki Waiora, School of Health, University of Waikato, Hamilton, New Zealand
- Waikato Regional Diabetes Service, Te Whatu Ora Health New Zealand Waikato, Hamilton, New Zealand
| | - Jonathan A Williman
- Biostatistics and Computation Biology Unit, University of Otago, Christchurch, New Zealand
| | - Alisa Boucsein
- Department of Women's and Children's Health, Dunedin School of Medicine, University of Otago, Dunedin, New Zealand
| | - Antony Watson
- Department of Paediatrics, University of Otago, Christchurch, New Zealand
| | - Rachael S Sampson
- Waikato Regional Diabetes Service, Te Whatu Ora Health New Zealand Waikato, Hamilton, New Zealand
| | - Oscar T Sergel-Stringer
- Department of Women's and Children's Health, Dunedin School of Medicine, University of Otago, Dunedin, New Zealand
| | - Celeste Keesing
- Waikato Regional Diabetes Service, Te Whatu Ora Health New Zealand Waikato, Hamilton, New Zealand
- Pinnacle Midlands Health Network, New Zealand
| | - Lynne Chepulis
- Te Huataki Waiora, School of Health, University of Waikato, Hamilton, New Zealand
| | - Benjamin J Wheeler
- Department of Women's and Children's Health, Dunedin School of Medicine, University of Otago, Dunedin, New Zealand
- Department of Paediatrics, Te Whatu Ora Southern, Dunedin, New Zealand
| | - Martin I de Bock
- Department of Paediatrics, University of Otago, Christchurch, New Zealand
- Department of Paediatrics, Te Whatu Ora Health New Zealand Waitaha Canterbury, Christchurch, New Zealand
| | - Ryan G Paul
- Te Huataki Waiora, School of Health, University of Waikato, Hamilton, New Zealand
- Waikato Regional Diabetes Service, Te Whatu Ora Health New Zealand Waikato, Hamilton, New Zealand
| |
Collapse
|
3
|
Jospe MR, Richardson KM, Saleh AA, Bohlen LC, Crawshaw J, Liao Y, Konnyu K, Schembre SM. Leveraging continuous glucose monitoring as a catalyst for behaviour change: a scoping review. Int J Behav Nutr Phys Act 2024; 21:74. [PMID: 38987796 PMCID: PMC11238504 DOI: 10.1186/s12966-024-01622-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Accepted: 06/27/2024] [Indexed: 07/12/2024] Open
Abstract
BACKGROUND Amidst the escalating prevalence of glucose-related chronic diseases, the advancements, potential uses, and growing accessibility of continuous glucose monitors (CGM) have piqued the interest of healthcare providers, consumers, and health behaviour researchers. Yet, there is a paucity of literature characterising the use of CGM in behavioural intervention research. This scoping review aims to describe targeted populations, health behaviours, health-related outcomes, and CGM protocols in randomised controlled trials (RCTs) that employed CGM to support health behaviour change. METHODS We searched Ovid MEDLINE, Elsevier Embase, Cochrane Central Register of Controlled Trials, EBSCOhost PsycINFO, and ProQuest Dissertations & Theses Global from inception to January 2024 for RCTs of behavioural interventions conducted in adults that incorporated CGM-based biological feedback. Citation searching was also performed. The review protocol was registered ( https://doi.org/10.17605/OSF.IO/SJREA ). FINDINGS Collectively, 5389 citations were obtained from databases and citation searching, 3995 articles were screened, and 31 were deemed eligible and included in the review. Most studies (n = 20/31, 65%) included adults with type 2 diabetes and reported HbA1c as an outcome (n = 29/31, 94%). CGM was most commonly used in interventions to target changes in diet (n = 27/31, 87%) and/or physical activity (n = 16/31, 52%). 42% (n = 13/31) of studies provided prospective CGM-based guidance on diet or activity, while 61% (n = 19/31) included retrospective CGM-based guidance. CGM data was typically unblinded (n = 24/31, 77%) and CGM-based biological feedback was most often provided through the CGM and two-way communication (n = 12/31, 39%). Communication typically occurred in-person (n = 13/31, 42%) once per CGM wear (n = 13/31; 42%). CONCLUSIONS This scoping review reveals a predominant focus on diabetes in CGM-based interventions, pointing out a research gap in its wider application for behaviour change. Future research should expand the evidence base to support the use of CGM as a behaviour change tool and establish best practices for its implementation. TRIAL REGISTRATION doi.org/10.17605/OSF.IO/SJREA.
Collapse
Affiliation(s)
- Michelle R Jospe
- Department of Oncology, Lombardi Comprehensive Cancer Center, Georgetown University, Washington DC, USA
| | - Kelli M Richardson
- School of Nutritional Sciences and Wellness, College of Agriculture, Life and Environmental Sciences, University of Arizona, Tucson, AZ, USA
| | - Ahlam A Saleh
- Arizona Health Sciences Library, University of Arizona, Tucson, AZ, USA
| | - Lauren C Bohlen
- Center for Health Promotion and Health Equity, Department of Behavioral and Social Sciences, Brown University School of Public Health, Providence, RI, USA
| | - Jacob Crawshaw
- Centre for Implementation Research, Ottawa Hospital Research Institute, Ottawa, ON, Canada
| | - Yue Liao
- Department of Kinesiology, College of Nursing and Health Innovation, University of Texas at Arlington, Arlington, TX, USA
| | - Kristin Konnyu
- Health Services Research Unit, Institute of Applied Health Sciences, University of Aberdeen, Aberdeen, Scotland
| | - Susan M Schembre
- Department of Oncology, Lombardi Comprehensive Cancer Center, Georgetown University, Washington DC, USA.
| |
Collapse
|
4
|
Seidu S, Kunutsor SK. Response to Comment on Seidu et al. Efficacy and Safety of Continuous Glucose Monitoring and Intermittently Scanned Continuous Glucose Monitoring in Patients With Type 2 Diabetes: A Systematic Review and Meta-analysis of Interventional Evidence. Diabetes Care 2024;47:169-179. Diabetes Care 2024; 47:e52-e53. [PMID: 38900948 DOI: 10.2337/dci24-0023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2024] [Accepted: 03/27/2024] [Indexed: 06/22/2024]
Affiliation(s)
- Samuel Seidu
- Diabetes Research Centre, National Institute for Health Research, Applied Research Collaboration East Midlands, University of Leicester, Leicester, U.K
- Diabetes Research Centre, University of Leicester, National Institute for Health Research Biomedical Research Centre, Leicester General Hospital, Leicester, U.K
| | - Setor K Kunutsor
- Diabetes Research Centre, National Institute for Health Research, Applied Research Collaboration East Midlands, University of Leicester, Leicester, U.K
- Diabetes Research Centre, University of Leicester, National Institute for Health Research Biomedical Research Centre, Leicester General Hospital, Leicester, U.K
| |
Collapse
|
5
|
Aleppo G. Comment on Seidu et al. Efficacy and Safety of Continuous Glucose Monitoring and Intermittently Scanned Continuous Glucose Monitoring in Patients With Type 2 Diabetes: A Systematic Review and Meta-analysis of Interventional Evidence. Diabetes Care 2024;47:169-179. Diabetes Care 2024; 47:e50-e51. [PMID: 38900946 DOI: 10.2337/dc24-0304] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/22/2024]
Affiliation(s)
- Grazia Aleppo
- Division of Endocrinology, Metabolism, and Molecular Medicine, Feinberg School of Medicine, Northwestern University, Chicago, IL
| |
Collapse
|
6
|
Jancev M, Vissers TACM, Visseren FLJ, van Bon AC, Serné EH, DeVries JH, de Valk HW, van Sloten TT. Continuous glucose monitoring in adults with type 2 diabetes: a systematic review and meta-analysis. Diabetologia 2024; 67:798-810. [PMID: 38363342 PMCID: PMC10954850 DOI: 10.1007/s00125-024-06107-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Accepted: 01/12/2024] [Indexed: 02/17/2024]
Abstract
AIMS/HYPOTHESIS Continuous glucose monitoring (CGM) is increasingly used in the treatment of type 2 diabetes, but the effects on glycaemic control are unclear. The aim of this systematic review and meta-analysis is to provide a comprehensive overview of the effect of CGM on glycaemic control in adults with type 2 diabetes. METHODS We performed a systematic review using Embase, MEDLINE, Web of Science, Scopus and ClinicalTrials.gov from inception until 2 May 2023. We included RCTs investigating real-time CGM (rtCGM) or intermittently scanned CGM (isCGM) compared with self-monitoring of blood glucose (SMBG) in adults with type 2 diabetes. Studies with an intervention duration <6 weeks or investigating professional CGM, a combination of CGM and additional glucose-lowering treatment strategies or GlucoWatch were not eligible. Change in HbA1c and the CGM metrics time in range (TIR), time below range (TBR), time above range (TAR) and glycaemic variability were extracted. We evaluated the risk of bias using the Cochrane risk-of-bias tool version 2. Data were synthesised by performing a meta-analysis. We also explored the effects of CGM on severe hypoglycaemia and micro- and macrovascular complications. RESULTS We found 12 RCTs comprising 1248 participants, with eight investigating rtCGM and four isCGM. Compared with SMBG, CGM use (rtCGM or isCGM) led to a mean difference (MD) in HbA1c of -3.43 mmol/mol (-0.31%; 95% CI -4.75, -2.11, p<0.00001, I2=15%; moderate certainty). This effect was comparable in studies that included individuals using insulin with or without oral agents (MD -3.27 mmol/mol [-0.30%]; 95% CI -6.22, -0.31, p=0.03, I2=55%), and individuals using oral agents only (MD -3.22 mmol/mol [-0.29%]; 95% CI -5.39, -1.05, p=0.004, I2=0%). Use of rtCGM showed a trend towards a larger effect (MD -3.95 mmol/mol [-0.36%]; 95% CI -5.46 to -2.44, p<0.00001, I2=0%) than use of isCGM (MD -1.79 mmol/mol [-0.16%]; 95% CI -5.28, 1.69, p=0.31, I2=64%). CGM was also associated with an increase in TIR (+6.36%; 95% CI +2.48, +10.24, p=0.001, I2=9%) and a decrease in TBR (-0.66%; 95% CI -1.21, -0.12, p=0.02, I2=45%), TAR (-5.86%; 95% CI -10.88, -0.84, p=0.02, I2=37%) and glycaemic variability (-1.47%; 95% CI -2.94, -0.01, p=0.05, I2=0%). Three studies reported one or more events of severe hypoglycaemia and macrovascular complications. In comparison with SMBG, CGM use led to a non-statistically significant difference in the incidence of severe hypoglycaemia (RR 0.66, 95% CI 0.15, 3.00, p=0.57, I2=0%) and macrovascular complications (RR 1.54, 95% CI 0.42, 5.72, p=0.52, I2=29%). No trials reported data on microvascular complications. CONCLUSIONS/INTERPRETATION CGM use compared with SMBG is associated with improvements in glycaemic control in adults with type 2 diabetes. However, all studies were open label. In addition, outcome data on incident severe hypoglycaemia and incident microvascular and macrovascular complications were scarce. REGISTRATION This systematic review was registered on PROSPERO (ID CRD42023418005).
Collapse
Affiliation(s)
- Milena Jancev
- Department of Vascular Medicine and Endocrinology, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Tessa A C M Vissers
- Department of Vascular Medicine and Endocrinology, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Frank L J Visseren
- Department of Vascular Medicine and Endocrinology, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Arianne C van Bon
- Department of Internal Medicine, Rijnstate Hospital, Arnhem, the Netherlands
| | - Erik H Serné
- Department of Internal Medicine, Amsterdam University Medical Center, Amsterdam, the Netherlands
| | - J Hans DeVries
- Department of Internal Medicine, Amsterdam University Medical Center, Amsterdam, the Netherlands
| | - Harold W de Valk
- Department of Vascular Medicine and Endocrinology, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Thomas T van Sloten
- Department of Vascular Medicine and Endocrinology, University Medical Center Utrecht, Utrecht, the Netherlands.
| |
Collapse
|
7
|
Uhl S, Choure A, Rouse B, Loblack A, Reaven P. Effectiveness of Continuous Glucose Monitoring on Metrics of Glycemic Control in Type 2 Diabetes Mellitus: A Systematic Review and Meta-analysis of Randomized Controlled Trials. J Clin Endocrinol Metab 2024; 109:1119-1131. [PMID: 37987208 DOI: 10.1210/clinem/dgad652] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Indexed: 11/22/2023]
Abstract
PURPOSE To provide a systematic review and meta-analysis synthesizing the findings of randomized controlled trials (RCTs) of continuous glucose monitors (CGMs) in the management of adults with type 2 diabetes mellitus (T2DM) on glucose control and clinical outcomes. METHODS MEDLINE, Embase, and Cochrane were searched for RCTs that assessed the effectiveness of real-time CGM (rt-CGM) or flash CGM (FGM) in adults (≥18 years) with T2DM that reported on at least 1 of the following outcomes: hemoglobin A1c (HbA1c), time in range, time in hyperglycemia, or time in hypoglycemia. The GRADE approach was used to assess certainty of evidence for primary outcomes. RESULTS Fourteen RCTs assessing CGM were included, with 825 patients in 9 RCTs using rt-CGM and 822 in 5 RCTs using FGM. Moderate certainty of evidence indicated that use of CGM had a modest but statistically significant reduction in HbA1c levels of about 0.32%. Our analyses of each device type separately showed similar reductions in HbA1c (0.34% and 0.33%, respectively, for rt-CGM and FGM), with trends for improvement in other glucose metrics favoring rt-CGM over self-monitored blood glucose. CONCLUSION Both rt-CGM and flash CGM led to modest but statistically significant declines in HbA1c among individuals with T2DM, with little heterogeneity in the results. However, the duration of the included RCTs was relatively short and few studies reported on important clinical outcomes, such as adverse events, emergency department use, or hospitalization. Longer term studies are needed to determine if the short-term improvements in glucose control leads to improvements in clinically important outcomes.
Collapse
Affiliation(s)
| | - Anuja Choure
- University of Arizona College of Medicine, Tucson, AZ 85724, USA
- Phoenix VA Healthcare System, Phoenix, AZ 85012, USA
| | | | | | - Peter Reaven
- Phoenix VA Healthcare System, Phoenix, AZ 85012, USA
| |
Collapse
|
8
|
Kong SY, Cho MK. Effects of Continuous Glucose Monitoring on Glycemic Control in Type 2 Diabetes: A Systematic Review and Meta-Analysis. Healthcare (Basel) 2024; 12:571. [PMID: 38470682 PMCID: PMC10931178 DOI: 10.3390/healthcare12050571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 02/26/2024] [Accepted: 02/26/2024] [Indexed: 03/14/2024] Open
Abstract
As the prevalence of diabetes is rapidly increasing, the use of continuous glucose monitoring, which is effective in improving glycemic control in type 2 diabetes, is increasing. METHODS Systematic review was performed according to PRISMA criteria. The search was conducted for articles published until 31 May 2023 in PubMed, CINAHL, Cochrane Library, EMBASE, ClinicalKey, etc. The meta-analysis involved the synthesis of effect size; tests of homogeneity and heterogeneity; trim and fill plot; Egger's regression test; and Begg's test for assessing publication bias. RESULTS 491 studies were searched, of which 17 studies that met the selection criteria were analyzed. The overall effect on HbA1c was -0.37 (95% CI, -0.63~-0.11, p < 0.001), with HbA1c decreasing significantly after CGM interventions. Sub-analyses showed that the study was statistically significant in those aged 60 years or older, when rt-CGM was used and when the study was performed in multiple centers. CONCLUSION The results of this study showed that intervention using CGM was effective in reducing HbA1c in type 2 diabetes. The factors identified in this study can be used as guidelines for developing future CGM intervention programs.
Collapse
Affiliation(s)
- Seung-Yeon Kong
- Referral Center, Chungbuk National University Hospital, Cheongju 28644, Republic of Korea;
| | - Mi-Kyoung Cho
- Department of Nursing Science, Chungbuk National University, Cheongju 28644, Republic of Korea
| |
Collapse
|
9
|
Lever CS, Williman JA, Boucsein A, Watson A, Sampson RS, Sergel-Stringer OT, Keesing C, Chepulis L, Wheeler BJ, de Bock MI, Paul RG. Study protocol: glycaemic outcomes in people with type 2 diabetes initiating continuous glucose monitoring: the 2GO-CGM study. J Diabetes Metab Disord 2023; 22:1779-1792. [PMID: 37969919 PMCID: PMC10638210 DOI: 10.1007/s40200-023-01244-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Accepted: 05/31/2023] [Indexed: 11/17/2023]
Abstract
Purpose Improving glycaemic control in type 2 diabetes (T2D) is essential to reducing social and health-economic burden of diabetes-related complications. Continuous glucose monitoring (CGM) has been established as beneficial in improving glycaemic control and reducing hypoglycaemia in people with type 1 diabetes, however data in T2D is limited. This study has been designed to assess the effect of initiating real-time CGM (rtCGM) on glycaemic control in a high-risk population of adults with T2D. Secondary objectives are to assess the cost-effectiveness and safety of rtCGM, and the effects of rtCGM on diet/lifestyle and the burden of diabetic complications, including cardiovascular risk. Methods This multicentre randomised controlled trial (RCT) will be conducted at three sites in New Zealand (Waikato, Christchurch and Dunedin). Eighty adults with T2D on insulin with suboptimal glycaemic control (HbA1c > 8.0% or 64 mmol/mol) will be randomised 1:1 to rtCGM or routine care with self-monitoring of blood glucose levels (SMBG) for three months. This intervention phase will be followed by a three-month continuation phase where SMBG group crossover to use rtCGM. Participants will then be invited to join the extension phase with continued use of rtCGM for a further 12 months. During the extension phase, both groups will independently titrate their insulin under the remote supervision of prescribing diabetes nurse specialists following an insulin titration algorithm. The primary outcome of the study is time in target glucose range (3.9-10 mmol/L or 70-180 mg/dL; TIR). Secondary outcomes include CGM metrics as per consensus statement recommendations, and HbA1c. Additional planned analyses include cardiovascular risk profile, incremental cost-effectiveness analyses, dietary patterns, and qualitative analyses. Trial registration number The trial was registered with the Australian New Zealand Clinical Trials Registry (ACTRN12621000889853) on 8 July 2021 and the World Health Organisation International Clinical Trial Registry Platform (Universal Trial Number U1111-1264-5822).
Collapse
Affiliation(s)
- Claire S. Lever
- Te Huataki Waiora, School of Health, University of Waikato, Hamilton, Aotearoa New Zealand
- Waikato Regional Diabetes Service, Te Whatu Ora Health New Zealand Waikato, Hamilton, New Zealand
- Aotearoa Diabetes Collective, Hamilton, Waikato New Zealand
| | | | - Alisa Boucsein
- Department of Women’s and Children’s Health, Dunedin School of Medicine, University of Otago, Dunedin, New Zealand
| | - Antony Watson
- Department of Paediatrics, University of Otago, Christchurch, New Zealand
| | - Rachael S. Sampson
- Waikato Regional Diabetes Service, Te Whatu Ora Health New Zealand Waikato, Hamilton, New Zealand
- Aotearoa Diabetes Collective, Hamilton, Waikato New Zealand
| | - Oscar T. Sergel-Stringer
- Department of Women’s and Children’s Health, Dunedin School of Medicine, University of Otago, Dunedin, New Zealand
| | - Celeste Keesing
- Waikato Regional Diabetes Service, Te Whatu Ora Health New Zealand Waikato, Hamilton, New Zealand
- Pinnacle Midlands Health Network, New Plymouth, New Zealand
| | - Lynne Chepulis
- Te Huataki Waiora, School of Health, University of Waikato, Hamilton, Aotearoa New Zealand
| | - Benjamin J. Wheeler
- Department of Women’s and Children’s Health, Dunedin School of Medicine, University of Otago, Dunedin, New Zealand
- Department of Paediatrics, Te Whatu Ora Southern, Dunedin, New Zealand
| | - Martin I. de Bock
- Department of Paediatrics, University of Otago, Christchurch, New Zealand
- Department of Paediatrics, Te Whatu Ora Health New Zealand Waitaha Canterbury, Christchurch, New Zealand
| | - Ryan G. Paul
- Te Huataki Waiora, School of Health, University of Waikato, Hamilton, Aotearoa New Zealand
- Waikato Regional Diabetes Service, Te Whatu Ora Health New Zealand Waikato, Hamilton, New Zealand
- Aotearoa Diabetes Collective, Hamilton, Waikato New Zealand
| |
Collapse
|
10
|
Keshet A, Shilo S, Godneva A, Talmor-Barkan Y, Aviv Y, Segal E, Rossman H. CGMap: Characterizing continuous glucose monitor data in thousands of non-diabetic individuals. Cell Metab 2023; 35:758-769.e3. [PMID: 37080199 DOI: 10.1016/j.cmet.2023.04.002] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Revised: 01/27/2023] [Accepted: 04/04/2023] [Indexed: 04/22/2023]
Abstract
Despite its rising prevalence, diabetes diagnosis still relies on measures from blood tests. Technological advances in continuous glucose monitoring (CGM) devices introduce a potential tool to expand our understanding of glucose control and variability in people with and without diabetes. Yet CGM data have not been characterized in large-scale healthy cohorts, creating a lack of reference for CGM data research. Here we present CGMap, a characterization of CGM data collected from over 7,000 non-diabetic individuals, aged 40-70 years, between 2019 and 2022. We provide reference values of key CGM-derived clinical measures that can serve as a tool for future CGM research. We further explored the relationship between CGM-derived measures and diabetes-related clinical parameters, uncovering several significant relationships, including associations of mean blood glucose with measures from fundus imaging and sleep monitoring. These findings offer novel research directions for understanding the influence of glucose levels on various aspects of human health.
Collapse
Affiliation(s)
- Ayya Keshet
- Department of Computer Science and Applied Mathematics, Weizmann Institute of Science, Rehovot, Israel; Department of Molecular Cell Biology, Weizmann Institute of Science, Rehovot, Israel
| | - Smadar Shilo
- Department of Computer Science and Applied Mathematics, Weizmann Institute of Science, Rehovot, Israel; Department of Molecular Cell Biology, Weizmann Institute of Science, Rehovot, Israel; The Jesse and Sara Lea Shafer Institute of Endocrinology and Diabetes, National Center for Childhood Diabetes, Schneider Children's Medical Center of Israel, Petah Tikva, Israel
| | - Anastasia Godneva
- Department of Computer Science and Applied Mathematics, Weizmann Institute of Science, Rehovot, Israel; Department of Molecular Cell Biology, Weizmann Institute of Science, Rehovot, Israel
| | - Yeela Talmor-Barkan
- Department of Computer Science and Applied Mathematics, Weizmann Institute of Science, Rehovot, Israel; Department of Molecular Cell Biology, Weizmann Institute of Science, Rehovot, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel-Aviv, Israel; Department of Cardiology, Rabin Medical Center, Petah-Tikva, Israel
| | - Yaron Aviv
- Sackler Faculty of Medicine, Tel Aviv University, Tel-Aviv, Israel; Department of Cardiology, Rabin Medical Center, Petah-Tikva, Israel
| | - Eran Segal
- Department of Computer Science and Applied Mathematics, Weizmann Institute of Science, Rehovot, Israel; Department of Molecular Cell Biology, Weizmann Institute of Science, Rehovot, Israel.
| | - Hagai Rossman
- Department of Computer Science and Applied Mathematics, Weizmann Institute of Science, Rehovot, Israel; Department of Molecular Cell Biology, Weizmann Institute of Science, Rehovot, Israel; Pheno.AI, Tel-Aviv, Israel.
| |
Collapse
|
11
|
Keshet A, Reicher L, Bar N, Segal E. Wearable and digital devices to monitor and treat metabolic diseases. Nat Metab 2023; 5:563-571. [PMID: 37100995 DOI: 10.1038/s42255-023-00778-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Accepted: 03/07/2023] [Indexed: 04/28/2023]
Abstract
Cardiometabolic diseases are a major public-health concern owing to their increasing prevalence worldwide. These diseases are characterized by a high degree of interindividual variability with regards to symptoms, severity, complications and treatment responsiveness. Recent technological advances, and the growing availability of wearable and digital devices, are now making it feasible to profile individuals in ever-increasing depth. Such technologies are able to profile multiple health-related outcomes, including molecular, clinical and lifestyle changes. Nowadays, wearable devices allowing for continuous and longitudinal health screening outside the clinic can be used to monitor health and metabolic status from healthy individuals to patients at different stages of disease. Here we present an overview of the wearable and digital devices that are most relevant for cardiometabolic-disease-related readouts, and how the information collected from such devices could help deepen our understanding of metabolic diseases, improve their diagnosis, identify early disease markers and contribute to individualization of treatment and prevention plans.
Collapse
Affiliation(s)
- Ayya Keshet
- Department of Computer Science and Applied Mathematics, Weizmann Institute of Science, Rehovot, Israel
- Department of Molecular Cell Biology, Weizmann Institute of Science, Rehovot, Israel
| | - Lee Reicher
- Department of Computer Science and Applied Mathematics, Weizmann Institute of Science, Rehovot, Israel
- Department of Molecular Cell Biology, Weizmann Institute of Science, Rehovot, Israel
- Lis Maternity and Women's Hospital, Tel Aviv Sourasky Medical Center, Tel Aviv University (affiliated with Sackler Faculty of Medicine), Tel Aviv, Israel
| | - Noam Bar
- Department of Computer Science and Applied Mathematics, Weizmann Institute of Science, Rehovot, Israel
- Department of Molecular Cell Biology, Weizmann Institute of Science, Rehovot, Israel
| | - Eran Segal
- Department of Computer Science and Applied Mathematics, Weizmann Institute of Science, Rehovot, Israel.
- Department of Molecular Cell Biology, Weizmann Institute of Science, Rehovot, Israel.
| |
Collapse
|
12
|
Boureau AS, Guyomarch B, Gourdy P, Allix I, Annweiler C, Cervantes N, Chapelet G, Delabrière I, Guyonnet S, Litke R, Paccalin M, Penfornis A, Saulnier PJ, Wargny M, Hadjadj S, de Decker L, Cariou B. Nocturnal hypoglycemia is underdiagnosed in older people with insulin-treated type 2 diabetes: The HYPOAGE observational study. J Am Geriatr Soc 2023. [PMID: 36965179 DOI: 10.1111/jgs.18341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 01/25/2023] [Accepted: 02/02/2023] [Indexed: 03/27/2023]
Abstract
BACKGROUND There is a lack of real-life data regarding the frequency and predictive factors of hypoglycemia in older patients with type 2 diabetes (T2D). This study aimed to determine the frequency and predictors of hypoglycemia in older patients with insulin-treated T2D. METHODS This prospective multicenter study included 155 insulin-treated T2D patients aged 75 years and older with ≥2 self-monitoring of blood glucose (SMBG) daily controls. Participants underwent a geriatric and diabetic assessment and received ambulatory blinded continuous glucose monitoring (CGM) for 28 consecutive days with FreeStyle Libre Pro® sensor. Study population (n = 141) has >70% CGM active time. Multivariable logistic regressions were used to identify factors associated with SMBG confirmed hypoglycemia (≥70 mg/dL) and with nocturnal level 2 time below range (glucose concentration <54 mg/dL during ≥15 consecutive min between 0.00 and 6.00 am). RESULTS The mean age of the 141 analyzed patients was 81.5 ± 5.3 years and 56.7% were male. The mean baseline HbA1c was 7.9% ± 1.0%. After geriatric assessment, 102 participants (72.3%) were considered as complex and 39 (27.7%) as healthy. The primary endpoint (confirmed SMBG <70 mg/dL) occurred in 37.6% patients. In multivariable analysis, the risk of SMBG-confirmed hypoglycemia was positively associated with a longer duration of diabetes (OR (+1 year) =1.04, (1.00-1.08), p = 0.04) and glycemic variability assessed by CGM (CV %) (OR (+1%) = 1.12, [1.05-1.19], p = <0.001). Nighty-two patients (65.2%) experienced nocturnal time in hypoglycemia (i.e., <54 mg/dL during ≥15 consecutive min between midnight and 6 a.m.). In multivariable analyses, cognitive impairment (OR: 9.31 [2.59-33.4]), heart failure (OR: 4.81 [1;48-15.6]), and depressive disorder (OR: 0.19 [0.06-0.53]) were associated with nocturnal time in hypoglycemia. CONCLUSION Nocturnal hypoglycemia is very common and largely underdiagnosed in older patients with insulin-treated T2D. CGM is a promising tool to better identify hypoglycemia and adapt diabetes management in this population.
Collapse
Affiliation(s)
- Anne-Sophie Boureau
- Nantes Université, CHU Nantes, Pole de Gérontologie Clinique, Nantes, F-44000, France
| | - Béatrice Guyomarch
- Nantes Université, CHU Nantes, CNRS, INSERM, l'institut du thorax, Nantes, F-44000, France
| | - Pierre Gourdy
- CHU de Toulouse & UMR1297/I2MC, Université de Toulouse, Toulouse, France
| | - Ingrid Allix
- Département d'Endocrinologie, Diabétologie, Nutrition, CHU de Angers, Angers, France
| | - Cédric Annweiler
- Department of Geriatric Medicine and Memory Clinic, Research Center on Autonomy and Longevity, University Hospital, Angers, France
- UPRES EA 4638, University of Angers, Angers, France
- Gérontopôle Autonomie Longévité des Pays de la Loire, Nantes, France
- Robarts Research Institute, Department of Medical Biophysics, Schulich School of Medicine and Dentistry, the University of Western Ontario, London, Ontario, Canada
| | | | - Guillaume Chapelet
- Nantes Université, CHU Nantes, Pole de Gérontologie Clinique, Nantes, F-44000, France
| | | | - Sophie Guyonnet
- Gerontopole of Toulouse, Institute of Ageing, Toulouse University Hospital (CHU Toulouse), Toulouse, France
| | - Rachel Litke
- CHU Lille, Geriatric Department, Lille, 59000, France
| | - Marc Paccalin
- CHU de Poitiers, Pôle de gériatrie, Poitiers, 86021, France
- Université de Poitiers, INSERM, CHU Poitiers, Centre d'Investigation Clinique CIC 1402, Poitiers, France
| | - Alfred Penfornis
- Centre Hospitalier Sud Francilien, F-91100 Corbeil-Essonnes, Université Paris-Saclay, France
| | - Pierre-Jean Saulnier
- Université de Poitiers, INSERM, CHU Poitiers, Centre d'Investigation Clinique CIC 1402, Poitiers, France
| | - Matthieu Wargny
- Nantes Université, CHU Nantes, CNRS, INSERM, l'institut du thorax, Nantes, F-44000, France
- Nantes Université, CHU Nantes, Pôle Hospitalo-Universitaire 11: Santé Publique, Clinique des données, INSERM, CIC 1413, Nantes, F-44000, France
| | - Samy Hadjadj
- Nantes Université, CHU Nantes, CNRS, INSERM, l'institut du thorax, Nantes, F-44000, France
| | - Laure de Decker
- Nantes Université, CHU Nantes, Pole de Gérontologie Clinique, Nantes, F-44000, France
| | - Bertrand Cariou
- Nantes Université, CHU Nantes, CNRS, INSERM, l'institut du thorax, Nantes, F-44000, France
| |
Collapse
|
13
|
Di Molfetta S, Caruso I, Cignarelli A, Natalicchio A, Perrini S, Laviola L, Giorgino F. Professional continuous glucose monitoring in patients with diabetes mellitus: A systematic review and meta-analysis. Diabetes Obes Metab 2023; 25:1301-1310. [PMID: 36661362 DOI: 10.1111/dom.14981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Revised: 01/11/2023] [Accepted: 01/17/2023] [Indexed: 01/21/2023]
Abstract
AIM To evaluate the effect on glucose control of professional continuous glucose monitoring (p-CGM)-based care as compared with standard care in the management of patients with type 1 and type 2 diabetes. MATERIALS AND METHODS The PubMed database was searched comprehensively to identify prospective or retrospective studies evaluating p-CGM as a diagnostic tool for subsequent implementation of lifestyle and/or medication changes and reporting glycated haemoglobin (HbA1c) as an outcome measure. RESULTS We found 872 articles, 22 of which were included in the meta-analysis. Overall, the use of p-CGM was associated with greater HbA1c reduction from baseline (-0.28%, 95% confidence interval [CI] -0.36% to -0.21%, I2 = 0%, P < 0.00001) than usual care, irrespective of type of diabetes, length of follow-up, frequency of continuous glucose monitoring (CGM) use and duration of CGM recording. In the few studies describing CGM-derived glucose metrics, p-CGM showed a beneficial effect on change in time in range from baseline (5.59%, 95% CI 0.12 to 11.06, I2 = 0%, P = 0.05) and a neutral effect on change in time below the target range from baseline (-0.11%, 95% CI -1.76% to 1.55%, I2 = 33%, P = 0.90). CONCLUSIONS In patients with type 1 and type 2 diabetes, p-CGM-driven care is superior to usual care in improving glucose control without increasing hypoglycaemia.
Collapse
Affiliation(s)
- Sergio Di Molfetta
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Irene Caruso
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Angelo Cignarelli
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Annalisa Natalicchio
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Sebastio Perrini
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Luigi Laviola
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Francesco Giorgino
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| |
Collapse
|
14
|
Grace T, Salyer J. Use of Real-Time Continuous Glucose Monitoring Improves Glycemic Control and Other Clinical Outcomes in Type 2 Diabetes Patients Treated with Less Intensive Therapy. Diabetes Technol Ther 2022; 24:26-31. [PMID: 34524013 PMCID: PMC8783626 DOI: 10.1089/dia.2021.0212] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Objective: Use of real-time continuous glucose monitoring (rtCGM) has been shown to improve glycemic control in patients with type 2 diabetes (T2D) who are treated with intensive insulin therapy. However, most T2D patients are denied coverage for rtCGM due to failure to meet payer eligibility requirements: treatment with ≥3 insulin injections (or pump) and history of 4 × /day blood glucose testing. We investigated the relevance of these criteria to successful rtCGM use. Methods: This 6-month, prospective, interventional, single-arm study assessed the clinical effects of use rtCGM in patients with T2D treated with basal insulin only or noninsulin therapy. Primary outcomes were changes in HbA1c, average glucose, glycemic variability (% coefficient of variation), and percent of time in range (%TIR), below range (%TBR) and above range (%TAR). Results: Thirty-eight patients were included in the analysis (10.1% ± 1.8% HbA1c, 54.7 ± 10.2 years, 35.6 ± 6.4 body mass index). At 6 months, we observed reductions in HbA1c (-3.0% ± 1.3%, P < 0.001) and average glucose (-23.6 ± 38.8, P < 0.001). %TIR increased 15.2 ± 22.3, from 57.0 ± 29.9 to 72.2 ± 23.6, P < 0.001, with all patients maintaining %TBR targets (<4% at 70 mg/dL, <1% at <54 mg/dL). No changes in glycemic variability were observed. The greatest improvements in %TIR and %TAR were seen in patients treated with ≤1 medication. Conclusions: rtCGM use was associated with significant glycemic improvements in T2D patients treated with basal insulin only or noninsulin therapy. Given the growing body of evidence supporting rtCGM use in this population, insurance eligibility criteria should be modified to expand rtCGM use by T2D patients treated with less intensive therapies.
Collapse
Affiliation(s)
- Thomas Grace
- Endocrinology & Diabetes Specialists of Northwest Ohio, Findlay, Ohio, USA
- Address correspondence to: Thomas Grace, MD, Endocrinology & Diabetes Specialists of Northwest Ohio, 1816 Chapel Drive, Suite J, Findlay, OH 45840, USA
| | - Jay Salyer
- Endocrinology & Diabetes Specialists of Northwest Ohio, Findlay, Ohio, USA
| |
Collapse
|
15
|
Lin R, Brown F, James S, Jones J, Ekinci E. Continuous glucose monitoring: A review of the evidence in type 1 and 2 diabetes mellitus. Diabet Med 2021; 38:e14528. [PMID: 33496979 DOI: 10.1111/dme.14528] [Citation(s) in RCA: 61] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Revised: 12/24/2020] [Accepted: 01/20/2021] [Indexed: 12/17/2022]
Abstract
CONTEXT AND AIM Continuous glucose monitoring (CGM) is becoming widely accepted as an adjunct to diabetes management. Compared to standard care, CGM can provide detailed information about glycaemic variability in an internationally standardised ambulatory glucose profile, enabling more informed user and clinician decision making. We aimed to review the evidence, user experience and cost-effectiveness of CGM. METHODS A literature search was conducted by combining subject headings 'CGM' and 'flash glucose monitoring', with key words 'type 1 diabetes' and 'type 2 diabetes', limited to '1999 to current'. Further evidence was obtained from relevant references of retrieved articles. RESULTS There is a strong evidence for CGM use in people with type 1 diabetes, with benefits of reduced glycated haemoglobin and hypoglycaemia, and increased time in range. While the evidence for CGM use in type 2 diabetes is less robust, similar benefits have been demonstrated. CGM can improve diabetes-related satisfaction in people with diabetes (PWD) and parents of children with diabetes, as well as the clinician experience. However, CGM does have limitations including cost, accuracy and perceived inconvenience. Cost-effectiveness analyses have indicated that CGM is a cost-effective adjunct to type 1 diabetes management that is associated with reduced diabetes-related complications and hospitalisation. CONCLUSIONS Continuous glucose monitoring is revolutionising diabetes management. It is a cost-effective adjunct to diabetes management that has the potential to improve glycaemic outcomes and quality of life in PWD, especially type 1 diabetes.
Collapse
MESH Headings
- Blood Glucose/analysis
- Blood Glucose Self-Monitoring/economics
- Blood Glucose Self-Monitoring/instrumentation
- Cost-Benefit Analysis/statistics & numerical data
- Diabetes Complications/epidemiology
- Diabetes Mellitus, Type 1/blood
- Diabetes Mellitus, Type 1/economics
- Diabetes Mellitus, Type 1/epidemiology
- Diabetes Mellitus, Type 1/therapy
- Diabetes Mellitus, Type 2/blood
- Diabetes Mellitus, Type 2/economics
- Diabetes Mellitus, Type 2/epidemiology
- Diabetes Mellitus, Type 2/therapy
- Glycated Hemoglobin/analysis
- Glycemic Control/economics
- Glycemic Control/instrumentation
- Glycemic Control/statistics & numerical data
- History, 20th Century
- History, 21st Century
- Hospitalization/statistics & numerical data
- Humans
- Patient Satisfaction/statistics & numerical data
- Quality of Life
Collapse
Affiliation(s)
- Rose Lin
- Department of Endocrinology, Austin Health, Heidelberg, Vic., Australia
- Department of Medicine, Austin Health, Heidelberg, Vic., Australia
| | - Fran Brown
- Melbourne Diabetes Education and Support, Heidelberg Heights, Vic., Australia
| | - Steven James
- School of Nursing, Midwifery and Paramedicine, University of the Sunshine Coast, Petrie, Qld, Australia
| | - Jessica Jones
- Department of Medicine, Austin Health, Heidelberg, Vic., Australia
- Melbourne Medical School, University of Melbourne (Austin Campus), Melbourne, Vic., Australia
| | - Elif Ekinci
- Department of Endocrinology, Austin Health, Heidelberg, Vic., Australia
- Department of Medicine, Austin Health, Heidelberg, Vic., Australia
- Melbourne Medical School, University of Melbourne (Austin Campus), Melbourne, Vic., Australia
| |
Collapse
|
16
|
Asarani NAM, Reynolds AN, Boucher SE, de Bock M, Wheeler BJ. Cutaneous Complications With Continuous or Flash Glucose Monitoring Use: Systematic Review of Trials and Observational Studies. J Diabetes Sci Technol 2020; 14:328-337. [PMID: 31452386 PMCID: PMC7196864 DOI: 10.1177/1932296819870849] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Continuous glucose monitoring (CGM)/flash glucose monitoring (FGM) use in diabetes management is increasing. Cutaneous complications associated with these devices were reported. We conducted a systematic review to provide an overview of cutaneous complications with CGM/FGM use. METHODS We identified observational studies and intervention trials that report on cutaneous complications with CGM/FGM use up to January 14, 2019. Studies were identified through Medline, Embase, and PubMed, or with hand searching of the previous publications. Screening was duplicated and data extracted to consider four main themes: incidence rate and severity, participant perspectives of cutaneous complications, potential solutions, and future directions in diabetic technology relevant to reducing cutaneous complications. RESULTS A total of 54 eligible studies were identified. The overall event rate of cutaneous complications reported from 19 trials was one event per eight weeks of sensor wear-time of which 1.5% were considered severe. The most common cutaneous complications were wear-related erythema, itching, and induration. Although skin irritations were the most common cause of CGM/FGM discontinuation, most users experienced less pain or discomfort with CGM/FGM than capillary blood glucose testing. Future technological advances may reduce, but not eliminate cutaneous complications. CONCLUSION The incidence rate of reported cutaneous complications with CGM/FGM use from the available literature is low, with one event per eight weeks of sensor wear-time. Reported complication severity was also low, leading to low rates of CGM/FGM discontinuation. However, there appear to be discrepancies between reporting in trial and observational data. Greater constancy in reporting is necessary to understand the frequency of this issue.
Collapse
Affiliation(s)
- Nurul A. Mohd Asarani
- Department of Women’s and Children’s
Health, Dunedin School of Medicine, University of Otago, New Zealand
| | - Andrew N. Reynolds
- Department of Medicine, Dunedin School
of Medicine, University of Otago, New Zealand
| | - Sara E. Boucher
- Department of Women’s and Children’s
Health, Dunedin School of Medicine, University of Otago, New Zealand
| | - Martin de Bock
- Department of Paediatrics, University of
Otago, Christchurch
| | - Benjamin J. Wheeler
- Department of Women’s and Children’s
Health, Dunedin School of Medicine, University of Otago, New Zealand
- Benjamin J. Wheeler, MBChB, PhD, Department
of Women’s and Children’s Health, Dunedin School of Medicine, University of
Otago, PO Box 56, Dunedin, Otago 9022, New Zealand.
| |
Collapse
|
17
|
Furler J, O'Neal D, Speight J, Blackberry I, Manski-Nankervis JA, Thuraisingam S, de La Rue K, Ginnivan L, Doyle R, Holmes-Truscott E, Khunti K, Dalziel K, Chiang J, Audehm R, Kennedy M, Clark M, Jenkins A, Lake AJ, Januszewski AS, Catchpool M, Liew D, Clarke P, Best J. Use of professional-mode flash glucose monitoring, at 3-month intervals, in adults with type 2 diabetes in general practice (GP-OSMOTIC): a pragmatic, open-label, 12-month, randomised controlled trial. Lancet Diabetes Endocrinol 2020; 8:17-26. [PMID: 31862147 DOI: 10.1016/s2213-8587(19)30385-7] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Revised: 10/30/2019] [Accepted: 11/04/2019] [Indexed: 01/22/2023]
Abstract
BACKGROUND Continuous glucose monitoring, either real-time (personal) or retrospective (professional mode), can identify day-to-day glucose profiles to guide management decisions for people with type 2 diabetes. We aimed to examine the effects of professional-mode flash glucose monitoring, done at 3-month intervals, in adults with type 2 diabetes in general practice. METHODS We did a pragmatic, two-arm, open label, 12-month, individually randomised controlled trial (GP-OSMOTIC) in 25 general practices in Victoria, Australia. Eligible participants were adults aged 18-80 years, with type 2 diabetes diagnosed for at least 1 year and HbA1c at least 5·5 mmol/mol (0·5%) above their target in the past month despite being prescribed at least two non-insulin glucose-lowering drugs, insulin, or both (with therapy stable for at least 4 months). We randomly assigned participants (1:1) to either use of a professional-mode flash glucose monitoring system or usual clinical care (control). All participants wore the flash glucose monitoring sensor at baseline, and electronic randomisation (using permuted block sizes of four and six, and stratified by clinic) was done after the sensor was attached. Masking of participants and treating clinicians to group allocation was not possible, but the study statistician was masked to allocation when analysing the data. At baseline, and 3, 6, 9, and 12 months, participants in the flash glucose monitoring group wore the professional-mode flash glucose monitoring sensor for 5-14 days before their general practice visit. The sensor recorded interstitial glucose concentrations every 15 min, but the glucose data were not available to the participant until their general practice visit, where the sensor output would be uploaded to a computer by the health professional and discussed. Control group participants wore the sensor at baseline and at 12 months for data analysis only, and had usual care visits every 3 months. The primary outcome was the between-group difference in mean HbA1c at 12 months. Secondary outcomes were the between-group differences in: mean percentage time in target glucose range (4-10 mmol/L), based on ambulatory glucose profile data at 12 months; mean diabetes-specific distress (assessed with the Problem Areas In Diabetes [PAID] scale) at 12 months; and mean HbA1c at 6 months. Analysis was done by intention to treat. This trial is registered at the Australian and New Zealand Clinical Trials Registry, ACTRN12616001372471. FINDINGS Between Oct 4, 2016, and Nov 17, 2017, we randomly assigned 299 adults: 149 to flash glucose monitoring and 150 to usual care. At 6 months, HbA1c was lower in the flash glucose monitoring group than in the usual care group (difference -0·5%, 95% CI -0·8% to -0·3%; p=0·0001). However, at 12 months (primary outcome), there was no significant between-group difference in estimated mean HbA1c (8·2% [95% CI 8·0 to 8·4] for flash glucose monitoring vs 8·5% [8·3 to 8·7] for usual care; between-group difference -0·3%, 95% CI -0·5 to 0·01; [66 mmol/mol, 95% CI 64 to 68 vs 69 mmol/mol, 67 to 72; between-group difference -3·0, 95% CI -5·0 to 0·1]; p=0·059). Mean percentage time spent in target glucose range at 12 months was 7·9% (95% CI 2·3 to 13·5) higher in the flash glucose monitoring group than in the usual care group (p=0·0060). Diabetes-specific distress PAID scores were unchanged at 12 months (between-group difference -0·7, 95% CI -3·3 to 1·9; p=0·61). No episodes of severe hypoglycaemia or treatment-related deaths were reported. One participant died during the study from causes unrelated to the intervention (following complications post-myocardial infarction with multiple comorbidities). INTERPRETATION Professional-mode flash glucose monitoring in adults with type 2 diabetes in general practice did not improve the primary outcome of HbA1c at 12 months or diabetes-specific distress compared with usual care, but did improve time in target glucose range at 12 months and HbA1c at 6 months. Our findings suggest that professional-mode flash glucose monitoring can be implemented in a pragmatic primary care environment. Although there was no change in HbA1c at 12 months, the improved time in target range might reflect the potential of the technology to support personalised clinical care by providing insights into glycaemic profiles for some people with type 2 diabetes. FUNDING National Health and Medical Research Council of Australia, Sanofi Australia, and Abbott Diabetes Care.
Collapse
Affiliation(s)
- John Furler
- Department of General Practice, University of Melbourne, Parkville, VIC, Australia.
| | - David O'Neal
- Department of Medicine, University of Melbourne, Parkville, VIC, Australia
| | - Jane Speight
- School of Psychology, Deakin University, Geelong, VIC, Australia; Australian Centre for Behavioural Research in Diabetes, Diabetes Victoria, Melbourne, VIC, Australia
| | - Irene Blackberry
- John Richards Centre for Rural Ageing Research, La Trobe Rural Health School, La Trobe University, Wodonga, VIC, Australia
| | | | | | - Katie de La Rue
- Department of General Practice, University of Melbourne, Parkville, VIC, Australia
| | - Louise Ginnivan
- Department of General Practice, University of Melbourne, Parkville, VIC, Australia
| | - Rebecca Doyle
- Department of General Practice, University of Melbourne, Parkville, VIC, Australia
| | - Elizabeth Holmes-Truscott
- School of Psychology, Deakin University, Geelong, VIC, Australia; Australian Centre for Behavioural Research in Diabetes, Diabetes Victoria, Melbourne, VIC, Australia
| | - Kamlesh Khunti
- Diabetes Research Centre, University of Leicester, Leicester General Hospital, Leicester, UK
| | - Kim Dalziel
- School of Global and Population Health, University of Melbourne, Parkville, VIC, Australia
| | - Jason Chiang
- Department of General Practice, University of Melbourne, Parkville, VIC, Australia
| | - Ralph Audehm
- Department of General Practice, University of Melbourne, Parkville, VIC, Australia
| | - Mark Kennedy
- Department of General Practice, University of Melbourne, Parkville, VIC, Australia
| | - Malcolm Clark
- Department of General Practice, University of Melbourne, Parkville, VIC, Australia
| | - Alicia Jenkins
- National Health and Medical Research Council of Australia Clinical Trials Centre, University of Sydney, Sydney, NSW, Australia
| | - Amelia J Lake
- School of Psychology, Deakin University, Geelong, VIC, Australia; Australian Centre for Behavioural Research in Diabetes, Diabetes Victoria, Melbourne, VIC, Australia
| | - Andrzej S Januszewski
- National Health and Medical Research Council of Australia Clinical Trials Centre, University of Sydney, Sydney, NSW, Australia
| | - Max Catchpool
- School of Global and Population Health, University of Melbourne, Parkville, VIC, Australia
| | - Danny Liew
- Centre of Cardiovascular Research and Education in Therapeutics, Monash University, Melbourne, VIC, Australia
| | - Philip Clarke
- School of Global and Population Health, University of Melbourne, Parkville, VIC, Australia
| | - James Best
- Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore; Imperial College London, London, UK
| |
Collapse
|
18
|
Janapala RN, Jayaraj JS, Fathima N, Kashif T, Usman N, Dasari A, Jahan N, Sachmechi I. Continuous Glucose Monitoring Versus Self-monitoring of Blood Glucose in Type 2 Diabetes Mellitus: A Systematic Review with Meta-analysis. Cureus 2019; 11:e5634. [PMID: 31700737 PMCID: PMC6822918 DOI: 10.7759/cureus.5634] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Accepted: 09/12/2019] [Indexed: 01/08/2023] Open
Abstract
Every eleventh adult has diabetes, and every third has prediabetes. Over 95% of diabetics are of type 2. It is well established that diabetes doubles the risk of heart disease and stroke apart from increasing the risk of microvascular complications. Hence, strict glycemic control is necessary. However, it increases the risk of hypoglycemia, especially in patients with longstanding diabetes. Continuous glucose monitors (CGM) use a sensor to continuously measure the glucose levels in the interstitial fluid every 10 seconds and gives out mean values every five minutes. CGMs are emerging tools in the management of type 2 diabetes. The prime objective of this review is to find out if there is enough supporting evidence, suggesting that continuous glucose monitoring is more effective than self-monitoring of blood glucose (SMBG) in type 2 diabetes. We conducted a systematic literature search in Medline (PubMed) looking for any studies addressing our objective. It is observed that there is a varying level of evidence supporting that employing a CGM can reduce glycated hemoglobin (HbA1c), hypoglycemic events, and increase patient satisfaction. However, some studies reported no significant benefits. This systematic review with meta-analysis concludes that the use of CGM in type 2 diabetes mellitus (T2DM) is beneficial, as it significantly reduces HbA1c compared to the usual method of SMBG. The pooled mean difference in HbA1c was -0.25 (-0.45, -0.06) and statistically significant (at p = 0.01) when comparing CGM to SMBG.
Collapse
Affiliation(s)
- Rajesh Naidu Janapala
- Internal Medicine, Icahn School of Medicine at Mount Sinai/Queens Hospital Center, New York, USA
| | - Joseph S Jayaraj
- Internal Medicine, California Institute of Behavioral Neurosciences and Psychology, Fairfield, USA
| | - Nida Fathima
- Internal Medicine, California Institute of Behavioral Neurosciences and Psychology, Fairfield, USA
| | - Tooba Kashif
- Internal Medicine, California Institute of Behavioral Neurosciences and Psychology, Fairfield, USA
| | - Norina Usman
- Internal Medicine, Veterans Affairs Palo Alto Health Care System - Stanford University School of Medicine, Palo Alto, USA
| | - Amulya Dasari
- Internal Medicine, California Institute of Behavioral Neurosciences and Psychology, Fairfield, USA
| | - Nusrat Jahan
- Internal Medicine, California Institute of Behavioral Neurosciences and Psychology, Fairfield, USA
| | - Issac Sachmechi
- Internal Medicine, Icahn School of Medicine at Mount Sinai/Queens Hospital Center, New York, USA
| |
Collapse
|
19
|
Ajjan RA, Jackson N, Thomson SA. Reduction in HbA1c using professional flash glucose monitoring in insulin-treated type 2 diabetes patients managed in primary and secondary care settings: A pilot, multicentre, randomised controlled trial. Diab Vasc Dis Res 2019; 16:385-395. [PMID: 31271312 PMCID: PMC6613178 DOI: 10.1177/1479164119827456] [Citation(s) in RCA: 52] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
AIM Analyse the effects of professional flash glucose monitoring system (FreeStyle Libre Pro™) on glycaemic control in insulin-treated type 2 diabetes. METHODS Primary (n = 17) and secondary care centres (n = 5) randomised 148 type 2 diabetes patients into three groups: (A) self-monitoring of blood glucose (n = 52), (B) self-monitoring of blood glucose and two Libre Pro sensor wears (n = 46) or (C) self-monitoring of blood glucose and four sensor wears (n = 50). Primary endpoint was time in range (glucose 3.9-10 mmol/L) within group C comparing baseline with days 172-187. Predefined secondary endpoints included HbA1c, hypoglycaemia and quality of life measures analysed within and between groups (clinicaltrials.gov, NCT02434315). RESULTS In group C, time in range in the first 14 days (baseline) and days 172-187 was similar at 15.0 ± 5.0 and 14.1 ± 4.7 h/day (mean ± SD), respectively, (p = 0.1589). In contrast, HbA1c reduced from baseline to study end within group C by 4.9 ± 8.8 mmol/mol (0.44% ± 0.81%; p = 0.0003). HbA1c was also lower in group C compared with A at study end by 5.4 ± 1.79 mmol/mol (0.48% ± 0.16%; p = 0.0041, adjusted mean ± SE), without increased time in hypoglycaemia (p = 0.1795). Treatment satisfaction scores improved in group C compared with A (p = 0.0225) and no device-related serious adverse events were reported. CONCLUSIONS Libre Pro can improve HbA1c and treatment satisfaction without increasing hypoglycaemic exposure in insulin-treated type 2 diabetes individuals managed in primary/secondary care centres.
Collapse
Affiliation(s)
- Ramzi A Ajjan
- St James’s University Hospital, Leeds Teaching Hospitals NHS Trust and LIGHT Laboratories: Leeds Institute of Cardiovascular and Metabolic Research, University of Leeds, Leeds, UK
| | | | | |
Collapse
|
20
|
Ida S, Kaneko R, Murata K. Utility of Real-Time and Retrospective Continuous Glucose Monitoring in Patients with Type 2 Diabetes Mellitus: A Meta-Analysis of Randomized Controlled Trials. J Diabetes Res 2019; 2019:4684815. [PMID: 30775385 PMCID: PMC6350576 DOI: 10.1155/2019/4684815] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Revised: 10/23/2018] [Accepted: 10/28/2018] [Indexed: 11/17/2022] Open
Abstract
In the present study, we aimed to investigate the effects of continuous glucose monitoring (CGM) on blood glucose levels, body weight, blood pressure, and hypoglycaemia in patients with type 2 diabetes mellitus using a meta-analysis of randomized controlled trials (RCTs). A literature search was performed using MEDLINE, Cochrane Controlled Trials Registry, and ClinicalTrials.gov. RCTs using CGM in patients with type 2 diabetes mellitus were then selected. Statistical analysis included calculation of the standardized mean difference (SMD) or risk ratio and 95% confidence intervals (CIs) using a random effects model. After literature search, seven RCTs (669 patients) satisfied the eligibility criteria established herein and were included into the meta-analysis. Compared with the self-monitoring blood glucose group, the CGM group exhibited significantly lower HbA1c levels (SMD, -0.35; 95% CI, -0.59--0.10; P = 0.006) and shorter time spent with hypoglycaemia (SMD, -0.42; 95% CI, -0.70--0.13; P = 0.004). Conversely, no differences in body weight and blood pressure were observed between the groups. CGM in patients with type 2 diabetes mellitus could reduce HbA1c levels and time spent with hypoglycaemia. However, because few RCTs were included in this present study and heterogeneity was also noted, care should be taken when interpreting the results.
Collapse
Affiliation(s)
- Satoshi Ida
- Department of Diabetes and Metabolism, Ise Red Cross Hospital, Mie, Japan
| | - Ryutaro Kaneko
- Department of Diabetes and Metabolism, Ise Red Cross Hospital, Mie, Japan
| | - Kazuya Murata
- Department of Diabetes and Metabolism, Ise Red Cross Hospital, Mie, Japan
| |
Collapse
|
21
|
Wood A, O'Neal D, Furler J, Ekinci EI. Continuous glucose monitoring: a review of the evidence, opportunities for future use and ongoing challenges. Intern Med J 2018; 48:499-508. [PMID: 29464891 DOI: 10.1111/imj.13770] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Revised: 01/20/2018] [Accepted: 01/29/2018] [Indexed: 12/14/2022]
Abstract
The advent of devices that can track interstitial glucose levels, which are closely related to blood glucose levels, on a near continuous basis, has facilitated better insights into patterns of glycaemia. Continuous glucose monitoring (CGM) therefore allows for more intensive monitoring of blood glucose levels and potentially improved glycaemic control. In the context of the announcement on 1 April 2017 that the Australian Government will fund CGM monitoring for people with type 1 diabetes under the age of 21 years, this paper provides a review of the evidence for CGM and some of the ongoing challenges. There is evidence that real-time CGM in type 1 diabetes improves HbA1c and hypoglycaemia, while in type 2 diabetes, the evidence is less robust. Initial barriers to widespread implementation of CGM included issues with accuracy and user friendliness; however, as the technology has evolved, these issues have largely improved. Ongoing barriers include cost, and weaker evidence for their benefit in certain populations such as those with type 2 diabetes and less glycaemic variability. CGM has the potential to reduce healthcare costs, although real-world studies, including cost-effectiveness analyses, are needed in this area.
Collapse
Affiliation(s)
- Anna Wood
- Department of Endocrinology, Austin Health, Repatriation Campus Heidelberg West, Melbourne, Victoria, Australia
| | - David O'Neal
- Department of Medicine, St Vincent's Hospital and The University of Melbourne, Melbourne, Victoria, Australia
| | - John Furler
- Department of General Practice, The University of Melbourne, Melbourne, Victoria, Australia
| | - Elif I Ekinci
- Department of Endocrinology, Austin Health, Repatriation Campus Heidelberg West, Melbourne, Victoria, Australia.,Department of Medicine, Austin Health and The University of Melbourne (Austin Campus), Melbourne, Victoria, Australia
| |
Collapse
|
22
|
Park C, Le QA. The Effectiveness of Continuous Glucose Monitoring in Patients with Type 2 Diabetes: A Systematic Review of Literature and Meta-analysis. Diabetes Technol Ther 2018; 20:613-621. [PMID: 30095980 DOI: 10.1089/dia.2018.0177] [Citation(s) in RCA: 62] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
BACKGROUND Continuous glucose monitoring (CGM) provides glucose trend information that can be used to guide treatment and motivate patients with diabetes. Currently, the evidence on effectiveness of CGM in patients with type 2 diabetes is debatable. We aim to provide a systematic review and meta-analysis to synthesize current evidence of effectiveness of CGM in adults with type 2 diabetes. MATERIALS AND METHODS Cochrane, Embase, PubMed, and Web of Science were searched to include all studies that reported effectiveness of CGM in terms of HbA1c in adults aged 18 and older, with type 2 diabetes, on any treatment for diabetes. Heterogeneity (I2) was used to determine the variability between studies. All data were analyzed using Review Manager 5.3 software. RESULTS Seven randomized controlled trials and three cohort studies, involving 1384 patients for real-time CGM (RT-CGM) and professional CGM (P-CGM) and 4902 patients for flash glucose monitoring (FGM), were included. RT-CGM and P-CGM were associated with a modest but statistically significant reduction in HbA1c of 0.20% (95% confidence interval [CI] -0.31 to -0.09) compared with control. Patients who received FGM had a nonsignificant reduction of 0.02% (95% CI -0.07 to 0.04) compared with control. The meta-analysis indicated a low heterogeneity between studies. CONCLUSION Our analysis of current evidence suggests that RT-CGM and P-CGM are effective in improving HbA1c in adults with type 2 diabetes. Due to insufficient evidence, it is premature to form conclusions on the effectiveness of FGM. Future multicenter trials accessing the effectiveness of CGM as well as safety and cost-effectiveness may be necessary.
Collapse
Affiliation(s)
- Cindy Park
- College of Pharmacy, Western University of Health Sciences , Pomona, California
| | - Quang A Le
- College of Pharmacy, Western University of Health Sciences , Pomona, California
| |
Collapse
|
23
|
|
24
|
Sierra JA, Shah M, Gill MS, Flores Z, Chawla H, Kaufman FR, Vigersky R. Clinical and economic benefits of professional CGM among people with type 2 diabetes in the United States: analysis of claims and lab data. J Med Econ 2018; 21:225-230. [PMID: 28994334 DOI: 10.1080/13696998.2017.1390474] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND It is estimated that one in 10 people in the US have a diagnosis of diabetes. Type 2 diabetes accounts for 95% of all cases in the US, with annual costs estimated to be $246 billion per year. This study investigated the impact of a glucose-measuring intervention to the burden of type 2 diabetes. OBJECTIVE This analysis seeks to understand how professional continuous glucose monitoring (professional CGM) impacts clinical and economic outcomes when compared to patients who are not prescribed professional CGM. METHODS This study utilized a large healthcare claims and lab dataset from the US, and identified a cohort of patients who were prescribed professional CGM as identified by CPT codes 95250 and 95251. It calculated economic and clinical outcomes 1 year before and 1 year after the use of professional CGM, using a generalized linear model. RESULTS Patients who utilized professional CGM saw an improvement in hemoglobin A1C. The "difference-in-difference" calculation for A1C was shown to be -0.44%. There was no statistically significant difference in growth of total annual costs for people who used professional CGM compared to those who did not ($1,270, p = .08). Patients using professional CGM more than once per year had a -$3,376 difference in the growth of total costs (p = .05). Patients who used professional CGM while changing their diabetes treatment regimen also had a difference of -$3,327 in growth of total costs (p = .0023). CONCLUSION Significant clinical benefits were observed for patients who used professional CGM. Economic benefits were observed for patients who utilized professional CGM more than once within a 1-year period or who used it during a change of diabetes therapy. This suggests that professional CGM may help decrease rising trends in healthcare costs for people with type 2 diabetes, while also improving clinical outcomes.
Collapse
Affiliation(s)
| | - Mona Shah
- a Medtronic Diabetes, Inc. , Northridge , CA , USA
| | - Max S Gill
- a Medtronic Diabetes, Inc. , Northridge , CA , USA
| | | | - Hiten Chawla
- a Medtronic Diabetes, Inc. , Northridge , CA , USA
| | | | | |
Collapse
|
25
|
Abstract
Continuous glucose monitoring (CGM) is developing into an increasingly useful tool for glucose monitoring and therapeutic guidance in the treatment of diabetes. Multiple daily doses of insulin (MDI) is the most common method for intensive insulin treatment of type 1 diabetes and is also becoming more common in the treatment of type 2 diabetes as an increasing population with type 2 diabetes experiences progressive beta cell loss. The clinical evidence demonstrating the benefit of CGM in the outcomes of patients treated with MDI is becoming clearer, particularly with the recent completion of several randomized clinical trials addressing both type 1 and 2 diabetes. This evidence is reviewed.
Collapse
Affiliation(s)
| | - Andrew Ahmann
- Oregon Health & Science University, Portland, Oregon
| |
Collapse
|
26
|
Vigersky R, Shrivastav M. Role of continuous glucose monitoring for type 2 in diabetes management and research. J Diabetes Complications 2017; 31:280-287. [PMID: 27818105 DOI: 10.1016/j.jdiacomp.2016.10.007] [Citation(s) in RCA: 78] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2016] [Accepted: 10/09/2016] [Indexed: 10/20/2022]
Abstract
The advent of continuous glucose monitoring (CGM) is a significant stride forward in our ability to better understand the glycemic status of our patients. Current clinical practice employs two forms of CGM: professional (retrospective or "masked") and personal (real-time) to evaluate and/or monitor glycemic control. Most studies using professional and personal CGM have been done in those with type 1 diabetes (T1D). However, this technology is agnostic to the type of diabetes and can also be used in those with type 2 diabetes (T2D). The value of professional CGM in T2D for physicians, patients, and researchers is derived from its ability to: (1) to discover previously unknown hyper- and hypoglycemia (silent and symptomatic); (2) measure glycemic control directly rather than through the surrogate metric of hemoglobin A1C (HbA1C) permitting the observation of a wide variety of metrics that include glycemic variability, the percent of time within, below and above target glucose levels, the severity of hypo- and hyperglycemia throughout the day and night; (3) provide actionable information for healthcare providers derived by the CGM report; (4) better manage patients on hemodialysis; and (5) effectively and efficiently analyze glycemic effects of new interventions whether they be pharmaceuticals (duration of action, pharmacodynamics, safety, and efficacy), devices, or psycho-educational. Personal CGM has also been successfully used in a small number of studies as a behavior modification tool in those with T2D. This comprehensive review describes the differences between professional and personal CGM and the evidence for the use of each form of CGM in T2D. Finally, the opinions of key professional societies on the use of CGM in T2D are presented.
Collapse
Affiliation(s)
| | - Maneesh Shrivastav
- Medtronic Plc, Non-Intensive Diabetes Therapies, 3033 Campus Drive, Minneapolis, MN 55441.
| |
Collapse
|
27
|
Ajjan RA, Abougila K, Bellary S, Collier A, Franke B, Jude EB, Rayman G, Robinson A, Singh BM. Sensor and software use for the glycaemic management of insulin-treated type 1 and type 2 diabetes patients. Diab Vasc Dis Res 2016; 13:211-9. [PMID: 27000105 DOI: 10.1177/1479164115624680] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Lowering glucose levels, while avoiding hypoglycaemia, can be challenging in insulin-treated patients with diabetes. We evaluated the role of ambulatory glucose profile in optimising glycaemic control in this population. Insulin-treated patients with type 1 and type 2 diabetes were recruited into a prospective, multicentre, 100-day study and randomised to control (n = 28) or intervention (n = 59) groups. The intervention group used ambulatory glucose profile, generated by continuous glucose monitoring, to assess daily glucose levels, whereas the controls relied on capillary glucose testing. Patients were reviewed at days 30 and 45 by the health care professional to adjust insulin therapy. Comparing first and last 2 weeks of the study, ambulatory glucose profile-monitored type 2 diabetes patients (n = 28) showed increased time in euglycaemia (mean ± standard deviation) by 1.4 ± 3.5 h/day (p = 0.0427) associated with reduction in HbA1c from 77 ± 15 to 67 ± 13 mmol/mol (p = 0.0002) without increased hypoglycaemia. Type 1 diabetes patients (n = 25) showed reduction in hypoglycaemia from 1.4 ± 1.7 to 0.8 ± 0.8 h/day (p = 0.0472) associated with a marginal HbA1c decrease from 75 ± 10 to 72 ± 8 mmol/mol (p = 0.0508). Largely similar findings were observed comparing intervention and control groups at end of study. In conclusion, ambulatory glucose profile helps glycaemic management in insulin-treated diabetes patients by increasing time spent in euglycaemia and decreasing HbA1c in type 2 diabetes patients, while reducing hypoglycaemia in type 1 diabetes patients.
Collapse
Affiliation(s)
- Ramzi A Ajjan
- St. James's University Hospital, Leeds Teaching Hospitals Trust and LIGHT Laboratories, University of Leeds, Leeds, UK
| | - Kamal Abougila
- County Durham and Darlington NHS Foundation Trust, County Durham, UK
| | - Srikanth Bellary
- Aston Research Centre for Healthy Ageing (ARCHA), Aston University, Birmingham, UK
| | | | - Bernd Franke
- Rotherham Hospital NHS Foundation Trust, Rotherham, UK
| | - Edward B Jude
- Tameside Hospital NHS Foundation Trust, Ashton-under-Lyne, UK
| | | | | | | |
Collapse
|
28
|
Abstract
Real-time continuous glucose monitoring (RT-CGM) has, in the span of just a few years, established an essential role in the contemporary management of type 1 diabetes. Nonetheless, masked CGM retains an important place in the management of diabetes including assisting with hypoglycemia detection and avoidance, optimizing glycemic control, and acting as a teaching tool for people living with diabetes.
Collapse
Affiliation(s)
- Ian Blumer
- Charles H. Best Diabetes Centre, Ajax, ON, Canada University of Toronto, 27 King's College Cir, Toronto, ON, Canada
| |
Collapse
|
29
|
Pazos-Couselo M, García-López JM, González-Rodríguez M, Gude F, Mayán-Santos JM, Rodríguez-Segade S, Rodríguez-García J, Casanueva F. High incidence of hypoglycemia in stable insulin-treated type 2 diabetes mellitus: continuous glucose monitoring vs. self-monitored blood glucose. Observational prospective study. Can J Diabetes 2015; 39:428-33. [PMID: 26254702 DOI: 10.1016/j.jcjd.2015.05.007] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2015] [Revised: 04/24/2015] [Accepted: 05/06/2015] [Indexed: 10/23/2022]
Abstract
OBJECTIVES Hypoglycemia is a limiting factor in the achievement of strict glycemic control. The primary objective of this 9-week study was to determine the frequency of hypoglycemia in patients with stable insulin-treated type 2 diabetes mellitus by comparing self-monitored blood glucose (SMBG) measurement with continuous glucose monitoring (CGM). METHODS This was an observational prospective study. Included in the study were 63 stable, insulin-treated patients with type 2 diabetes. They were instructed to record 2 daily capillary blood glucose readings, pre- and/or postprandial, in a sequential way during 8 consecutive weeks. A CGM system was worn during an additional week. We evaluated the frequency of hypoglycemia using the 8-week SMBG profile and the 1 CGM week. RESULTS SMBG revealed that 50% of the patients had experienced hypoglycemia. CGM found hypoglycemia in 59% of patients. Significantly higher percentages of hyperglycemic and hypoglycemic episodes were detected by CGM than by capillary blood glucose measurements (61.1% vs. 50.8%; p=0.047) and (3.8% vs. 1.7%; p=0.016); 33% of patients experienced nocturnal hypoglycemia, and 19% of patients who had no data concerning hypoglycemia recorded in the capillary blood glucose diary had experienced hypoglycemia as measured by CGM, and the hypoglycemia occurred mainly during the nocturnal period. CONCLUSIONS In stable well-controlled, insulin-treated patients with type 2 diabetes, CGM showed higher numbers of hypoglycemic events than did SMBG, especially at night. CGM is a useful tool that provides clinically valuable information about glucose control in these patients.
Collapse
Affiliation(s)
- Marcos Pazos-Couselo
- Hospital Complex Santiago de Compostela, Endocrinology and Nutrition Service, Santiago de Compostela, Spain.
| | - Jose Manuel García-López
- Hospital Complex Santiago de Compostela, Endocrinology and Nutrition Service, Santiago de Compostela, Spain
| | - Maria González-Rodríguez
- Hospital Complex Santiago de Compostela, Endocrinology and Nutrition Service, Santiago de Compostela, Spain
| | - Francisco Gude
- Hospital Complex Santiago de Compostela, Clinical Epidemiology Unit, Santiago de Compostela, Spain
| | | | - Santiago Rodríguez-Segade
- University of Santiago de Compostela, Biochemistry and Molecular Biology, Santiago de Compostela, Spain
| | - Javier Rodríguez-García
- University of Santiago de Compostela, Biochemistry and Molecular Biology, Santiago de Compostela, Spain
| | - Felipe Casanueva
- Hospital Complex Santiago de Compostela, Endocrinology and Nutrition Service, Santiago de Compostela, Spain; Physiopathology of Obesity and Nutrition Biomedical Research Network Consortium, Santiago de Compostela, Spain
| |
Collapse
|
30
|
Tang TS, Digby EM, Wright AM, Chan JHM, Mazanderani AB, Ross SA, Tildesley HG, Lee AM, White AS, Tildesley HD. Real-time continuous glucose monitoring versus internet-based blood glucose monitoring in adults with type 2 diabetes: a study of treatment satisfaction. Diabetes Res Clin Pract 2014; 106:481-6. [PMID: 25458333 DOI: 10.1016/j.diabres.2014.09.050] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Revised: 06/03/2014] [Accepted: 09/14/2014] [Indexed: 11/18/2022]
Abstract
AIMS To compare treatment satisfaction between real-time continuous glucose monitoring (RT-CGM) and internet-blood glucose monitoring (IBGM) in adults with type 2 diabetes treated with insulin. METHODS This study recruited 40 patients who completed a parallel randomized controlled trial comparing a RT-CGM to an IBGM. Patients in the RT-CGM group monitored their blood-glucose levels bi-weekly and emailed results to their endocrinologist. Patients in the IBGM group also monitored their blood-glucose levels bi-weekly, but entered their data into an IBGM. Both groups used a secure website to submit blood-glucose readings and to receive feedback from their endocrinologist. Feedback included changes in therapy, suggestions on testing frequency, lifestyle modifications and/or encouragement to continue with no changes. At the end of 6 months, treatment satisfaction was measured using the 8-item Diabetes Treatment Satisfaction Questionnaire. In this study, "treatment" refers to the blood glucose monitoring system to which patients were randomized. RESULTS Thirty-two of the 40 patients completed the treatment satisfaction questionnaire (80%). Compared to the RT-CGM group, the IBGM group reported a significantly higher level of overall treatment satisfaction (24.80 vs. 33.41, p<0.000). Ratings of individual satisfaction components including convenience, flexibility, likelihood of recommending treatment to others, and willingness to continue with treatment were also found to be significantly higher in the IBGM group. CONCLUSION Patients using IBGM are more satisfied with their blood glucose monitoring system compared to those using RT-CGM.
Collapse
Affiliation(s)
- Tricia S Tang
- Department of Medicine, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.
| | | | | | | | | | - Stuart A Ross
- Department of Medicine, University of Calgary, Calgary, AB, Canada
| | | | | | - Adam S White
- Department of Medicine, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
| | - Hugh D Tildesley
- Department of Medicine, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
| |
Collapse
|
31
|
Scuffi C. Interstitium versus Blood Equilibrium in Glucose Concentration and its Impact on Subcutaneous Continuous Glucose Monitoring Systems. EUROPEAN ENDOCRINOLOGY 2014; 10:36-42. [PMID: 29872462 PMCID: PMC5983095 DOI: 10.17925/ee.2014.10.01.36] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2013] [Accepted: 02/13/2014] [Indexed: 12/18/2022]
Abstract
The relationship between both interstitial and blood glucose remains a debated topic, on which there is still no consensus. The experimental evidence suggests that blood and interstitial fluid glucose levels are correlated by a kinetic equilibrium, which as a consequence has a time and magnitude gradient in glucose concentration between blood and interstitium. Furthermore, this equilibrium can be perturbed by several physiological effects (such as foreign body response, wound-healing effect, etc.), with a consequent reduction of interstitial fluid glucose versus blood glucose correlation. In the present study, the impact of operating in the interstitium on continuous glucose monitoring systems (CGMs) will be discussed in depth, both for the application of CGMs in the management of diabetes and in other critical areas, such as tight glycaemic control in critically ill patients.
Collapse
Affiliation(s)
- Cosimo Scuffi
- Scientist, Scientific and Technology Affairs Department, A. Menarini Diagnostics, Florence, Italy
| |
Collapse
|
32
|
Berard LD, Blumer I, Houlden R, Miller D, Woo V. Surveillance du contrôle de la glycémie. Can J Diabetes 2013. [DOI: 10.1016/j.jcjd.2013.07.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
33
|
|
34
|
Poolsup N, Suksomboon N, Kyaw AM. Systematic review and meta-analysis of the effectiveness of continuous glucose monitoring (CGM) on glucose control in diabetes. Diabetol Metab Syndr 2013; 5:39. [PMID: 23876067 PMCID: PMC3728077 DOI: 10.1186/1758-5996-5-39] [Citation(s) in RCA: 98] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2013] [Accepted: 07/21/2013] [Indexed: 02/03/2023] Open
Abstract
Diabetes mellitus is a chronic disease that necessitates continuing treatment and patient self-care education. Monitoring of blood glucose to near normal level without hypoglycemia becomes a challenge in the management of diabetes. Although self monitoring of blood glucose (SMBG) can provide daily monitoring of blood glucose level and help to adjust therapy, it cannot detect hypoglycemic unawareness and nocturnal hypoglycemia which occurred mostly in T1DM pediatrics. Continuous glucose monitoring (CGM) offers continuous glucose data every 5 minutes to adjust insulin therapy especially for T1DM patients and to monitor lifestyle intervention especially for T2DM patients by care providers or even patients themselves. The main objective of this study was to assess the effects of continuous glucose monitoring (CGM) on glycemic control in Type 1 diabetic pediatrics and Type 2 diabetic adults by collecting randomized controlled trials from MEDLINE (pubmed), SCOPUS, CINAHL, Web of Science and The Cochrane Library up to May 2013 and historical search through the reference lists of relevant articles. There are two types of CGM device: real-time CGM and retrospective CGM and both types of the device were included in the analysis. In T1DM pediatrics, CGM use was no more effective than SMBG in reducing HbA1c [mean difference - 0.13% (95% CI -0.38% to 0.11%,]. This effect was independent of HbA1c level at baseline. Subgroup analysis indicated that retrospective CGM was not superior to SMBG [mean difference -0.05% (95% CI -0.46% to 0.35%)]. In contrast, real-time CGM revealed better effect in lowering HbA1c level compared with SMBG [mean difference -0.18% (95% CI -0.35% to -0.02%, p = 0.02)]. In T2DM adults, significant reduction in HbA1c level was detected with CGM compared with SMBG [mean difference - 0.31% (95% CI -0.6% to -0.02%, p = 0.04)]. This systematic review and meta-analysis suggested that real-time CGM can be more effective than SMBG in T1DM pediatrics, though retrospective CGM was not. CGM provided better glycemic control in T2DM adults compared with SMBG.
Collapse
Affiliation(s)
- Nalinee Poolsup
- Department of Pharmacy, Faculty of Pharmacy, Silpakorn University, Nakhon-Pathom, Thailand
| | - Naeti Suksomboon
- Department of Pharmacy, Faculty of Pharmacy, Mahidol University, Bangkok, Thailand
| | - Aye Mon Kyaw
- Department of Pharmacy, Faculty of Pharmacy, Mahidol University, Bangkok, Thailand
| |
Collapse
|
35
|
Benhamou PY, Catargi B, Delenne B, Guerci B, Hanaire H, Jeandidier N, Leroy R, Meyer L, Penfornis A, Radermecker RP, Renard E, Baillot-Rudoni S, Riveline JP, Schaepelynck P, Sola-Gazagnes A, Sulmont V, Tubiana-Rufi N, Durain D, Mantovani I, Sola-Gazagnes A, Riveline JP. Real-time continuous glucose monitoring (CGM) integrated into the treatment of type 1 diabetes: consensus of experts from SFD, EVADIAC and SFE. DIABETES & METABOLISM 2012; 38 Suppl 4:S67-83. [PMID: 22980520 DOI: 10.1016/s1262-3636(12)71538-0] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- P-Y Benhamou
- Service Endocrinologie-Diabétologie-Nutrition, CHU Grenoble, et Université Grenoble-1, France
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Floyd B, Chandra P, Hall S, Phillips C, Alema-Mensah E, Strayhorn G, Ofili EO, Umpierrez GE. Comparative analysis of the efficacy of continuous glucose monitoring and self-monitoring of blood glucose in type 1 diabetes mellitus. J Diabetes Sci Technol 2012; 6:1094-102. [PMID: 23063035 PMCID: PMC3570843 DOI: 10.1177/193229681200600513] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
BACKGROUND Self-monitoring of blood glucose (SMBG) and continuous glucose monitoring (CGM) have been proven effective in improving hemoglobin A1c (HbA1c) and in reducing hypoglycemia in patients with type 1 diabetes mellitus (T1DM). It is not clear, however, if CGM provides further efficacy and safety benefits beyond SMBG in the management of T1DM. METHODS MEDLINE (1966-November 2009), COCHRANE REGISTRY (all years), and EMBASE (1980-November 2009), and article bibliographies were searched for randomized controlled trials (RCTs) investigating the use of CGM in patients with T1DM, with clinical outcomes, including HbA1c and hypoglycemia and/or hyperglycemia. RESULTS Fourteen RCTs met eligibility criteria [n = 1188 patients, 97.4% with T1DM, age 29.0 ± 14.3 years, diabetes duration 11.7 ± 7.0 years, and baseline HbA1c 8.3 ± 0.8% (mean ± standard deviation)]. Compared with SMBG, the use of CGM was associated with a greater reduction in HbA1c [-0.3% (confidence interval: 0.4, -0.2), p < .0001]. The number of hypoglycemic events was not significantly different between the CGM and SMBG groups (0.52 ± 0.52 versus 0.52 ± 0.63 events/day, p = .5), but duration of hypoglycemia was shorter for the CGM group (75 ± 39 versus 89 ± 19 min/day), with an incremental reduction of hypoglycemia duration of -15.2 min/day, p < .0001. Continuous glucose monitoring also resulted in a shorter duration of hyperglycemia than SMBG (172 ± 125 versus 217 ± 152 min/day, p = .04). CONCLUSIONS The use of CGM is associated with improvement in metabolic control in T1DM, with significant short- and long-term reductions in HbA1c and reduction in the duration of periods of hypoglycemia and hyperglycemia versus SMBG.
Collapse
Affiliation(s)
- Baraka Floyd
- Department of Medicine, Clinical Research Center, Morehouse School of Medicine, Atlanta, Georgia
| | - Prakash Chandra
- Department of Medicine, Emory University Hospital, Atlanta, Georgia
| | - Stephanie Hall
- Department of Medicine, Clinical Research Center, Morehouse School of Medicine, Atlanta, Georgia
| | - Christopher Phillips
- Department of Medicine, Clinical Research Center, Morehouse School of Medicine, Atlanta, Georgia
| | - Ernest Alema-Mensah
- Department of Medicine, Clinical Research Center, Morehouse School of Medicine, Atlanta, Georgia
| | - Gregory Strayhorn
- Department of Medicine, Clinical Research Center, Morehouse School of Medicine, Atlanta, Georgia
| | - Elizabeth O. Ofili
- Department of Medicine, Clinical Research Center, Morehouse School of Medicine, Atlanta, Georgia
| | | |
Collapse
|
37
|
Intraindividual differences between two simultaneous glucose measurement systems in type 2 diabetic patients. Wien Klin Wochenschr 2012; 124:453-60. [PMID: 22766578 DOI: 10.1007/s00508-012-0201-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2011] [Accepted: 06/12/2012] [Indexed: 10/28/2022]
Abstract
AIMS Continuous glucose measurement systems are an established tool to support diabetes therapy. Because of different technical solutions one can propose different potential limitations in daily practice. So we tried to identify the accuracy of two different devices head to head in daily routine to point out individual characteristics. METHODS We included 24 patients with type 2 diabetes mellitus to wear the GlucoDay and the MiniMed continuous glucose measurement system at the same time for 48 h. We examined the mean differences in simultaneous glucose measurements, the confidence intervals were calculated by standard methods based on the t-distribution. RESULTS Comparison of glucose levels of both continuous glucose measurement systems showed that there was a tendency for higher glucose levels measured by the GlucoDay device. These differences were dependent on the time of the day. The absolute difference between two consecutive glucose measurements was higher for the GlucoDay system what means a somehow higher fluctuation of the GlucoDay measurements. CONCLUSIONS The differences in intraindividual comparison of the GlucoDay and the MiniMed continuous glucose measurement systems in type 2 diabetic patients may be taken into account when using different systems for detection of nocturnal hypoglycemia and the observation of trends used for therapeutic decisions.
Collapse
|
38
|
Langendam M, Luijf YM, Hooft L, Devries JH, Mudde AH, Scholten RJPM. Continuous glucose monitoring systems for type 1 diabetes mellitus. Cochrane Database Syst Rev 2012; 1:CD008101. [PMID: 22258980 PMCID: PMC6486112 DOI: 10.1002/14651858.cd008101.pub2] [Citation(s) in RCA: 106] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
BACKGROUND Self-monitoring of blood glucose is essential to optimise glycaemic control in type 1 diabetes mellitus. Continuous glucose monitoring (CGM) systems measure interstitial fluid glucose levels to provide semi-continuous information about glucose levels, which identifies fluctuations that would not have been identified with conventional self-monitoring. Two types of CGM systems can be defined: retrospective systems and real-time systems. Real-time systems continuously provide the actual glucose concentration on a display. Currently, the use of CGM is not common practice and its reimbursement status is a point of debate in many countries. OBJECTIVES To assess the effects of CGM systems compared to conventional self-monitoring of blood glucose (SMBG) in patients with diabetes mellitus type 1. SEARCH METHODS We searched The Cochrane Library, MEDLINE, EMBASE and CINAHL for the identification of studies. Last search date was June 8, 2011. SELECTION CRITERIA Randomised controlled trials (RCTs) comparing retrospective or real-time CGM with conventional self-monitoring of blood glucose levels or with another type of CGM system in patients with type 1 diabetes mellitus. Primary outcomes were glycaemic control, e.g. level of glycosylated haemoglobin A1c (HbA1c) and health-related quality of life. Secondary outcomes were adverse events and complications, CGM derived glycaemic control, death and costs. DATA COLLECTION AND ANALYSIS Two authors independently selected the studies, assessed the risk of bias and performed data-extraction. Although there was clinical and methodological heterogeneity between studies an exploratory meta-analysis was performed on those outcomes the authors felt could be pooled without losing clinical merit. MAIN RESULTS The search identified 1366 references. Twenty-two RCTs meeting the inclusion criteria of this review were identified. The results of the meta-analyses (across all age groups) indicate benefit of CGM for patients starting on CGM sensor augmented insulin pump therapy compared to patients using multiple daily injections of insulin (MDI) and standard monitoring blood glucose (SMBG). After six months there was a significant larger decline in HbA1c level for real-time CGM users starting insulin pump therapy compared to patients using MDI and SMBG (mean difference (MD) in change in HbA1c level -0.7%, 95% confidence interval (CI) -0.8% to -0.5%, 2 RCTs, 562 patients, I(2)=84%). The risk of hypoglycaemia was increased for CGM users, but CIs were wide and included unity (4/43 versus 1/35; RR 3.26, 95% CI 0.38 to 27.82 and 21/247 versus 17/248; RR 1.24, 95% CI 0.67 to 2.29). One study reported the occurrence of ketoacidosis from baseline to six months; there was however only one event. Both RCTs were in patients with poorly controlled diabetes.For patients starting with CGM only, the average decline in HbA1c level six months after baseline was also statistically significantly larger for CGM users compared to SMBG users, but much smaller than for patients starting using an insulin pump and CGM at the same time (MD change in HbA1c level -0.2%, 95% CI -0.4% to -0.1%, 6 RCTs, 963 patients, I(2)=55%). On average, there was no significant difference in risk of severe hypoglycaemia or ketoacidosis between CGM and SMBG users. The confidence interval however, was wide and included a decreased as well as an increased risk for CGM users compared to the control group (severe hypoglycaemia: 36/411 versus 33/407; RR 1.02, 95% CI 0.65 to 1.62, 4 RCTs, I(2)=0% and ketoacidosis: 8/411 versus 8/407; RR 0.94, 95% CI 0.36 to 2.40, 4 RCTs, I(2)=0%).Health-related quality of life was reported in five of the 22 studies. In none of these studies a significant difference between CGM and SMBG was found. Diabetes complications, death and costs were not measured.There were no studies in pregnant women with diabetes type 1 and in patients with hypoglycaemia unawareness. AUTHORS' CONCLUSIONS There is limited evidence for the effectiveness of real-time continuous glucose monitoring (CGM) use in children, adults and patients with poorly controlled diabetes. The largest improvements in glycaemic control were seen for sensor-augmented insulin pump therapy in patients with poorly controlled diabetes who had not used an insulin pump before. The risk of severe hypoglycaemia or ketoacidosis was not significantly increased for CGM users, but as these events occurred infrequent these results have to be interpreted cautiously.There are indications that higher compliance of wearing the CGM device improves glycosylated haemoglobin A1c level (HbA1c) to a larger extent.
Collapse
Affiliation(s)
- Miranda Langendam
- Dutch Cochrane Centre, AcademicMedical Center, Amsterdam, Netherlands.
| | | | | | | | | | | |
Collapse
|
39
|
Gandhi GY, Kovalaske M, Kudva Y, Walsh K, Elamin MB, Beers M, Coyle C, Goalen M, Murad MS, Erwin PJ, Corpus J, Montori VM, Murad MH. Efficacy of continuous glucose monitoring in improving glycemic control and reducing hypoglycemia: a systematic review and meta-analysis of randomized trials. J Diabetes Sci Technol 2011; 5:952-65. [PMID: 21880239 PMCID: PMC3192603 DOI: 10.1177/193229681100500419] [Citation(s) in RCA: 79] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVE We conducted a systematic review and meta-analysis to assess the efficacy of continuous glucose monitoring (CGM) in improving glycemic control and reducing hypoglycemia compared to self-monitored blood glucose (SMBG). METHODS We searched MEDLINE, EMBASE, Cochrane Central, Web of Science, and Scopus for randomized trials of adults and children with type 1 or type 2 diabetes mellitus (T1DM or T2DM). Pairs of reviewers independently selected studies, assessed methodological quality, and extracted data. Meta-analytic estimates of treatment effects were generated using a random-effects model. RESULTS Nineteen trials were eligible and provided data for meta-analysis. Overall, CGM was associated with a significant reduction in mean hemoglobin A1c [HbA1c; weighted mean difference (WMD) of -0.27% (95% confidence interval [CI] -0.44 to -0.10)]. This was true for adults with T1DM as well as T2DM [WMD -0.50% (95% CI -0.69 to -0.30) and -0.70 (95% CI, -1.14 to -0.27), respectively]. No significant effect was noted in children and adolescents. There was no significant difference in HbA1c reduction between studies of real-time versus non-realtime devices (WMD -0.22%, 95% CI, -0.59 to 0.15 versus -0.30%, 95% CI, -0.49 to -0.10; p for interaction 0.71). The quality of evidence was moderate due to imprecision, suggesting increased risk for bias. Data for the incidence of severe or nocturnal hypoglycemia were sparse and imprecise. In studies that reported patient satisfaction, users felt confident about the device and gave positive reviews. CONCLUSION Continuous glucose monitoring seems to help improve glycemic control in adults with T1DM and T2DM. The effect on hypoglycemia incidence is imprecise and unclear. Larger trials with longer follow-up are needed to assess the efficacy of CGM in reducing patient-important complications without significantly increasing the burden of care for patients with diabetes.
Collapse
Affiliation(s)
- Gunjan Y Gandhi
- Division of Endocrinology, Mayo Clinic, Jacksonville, Florida 32224, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Thielen V, Scheen A, Bringer J, Renard E. Attempt to improve glucose control in type 2 diabetic patients by education about real-time glucose monitoring. DIABETES & METABOLISM 2010; 36:240-3. [DOI: 10.1016/j.diabet.2010.03.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2010] [Revised: 03/15/2010] [Accepted: 03/18/2010] [Indexed: 11/30/2022]
|
41
|
Current literature in diabetes. Diabetes Metab Res Rev 2010; 26:i-xi. [PMID: 20474064 DOI: 10.1002/dmrr.1019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|