1
|
Ananchuensook P, Wongpiyabovorn J, Avihingsanon A, Tangkijvanich P. Performance of Elecsys ® HCV Duo Immunoassay for Diagnosis and Assessment of Treatment Response in HCV Patients with or without HIV Infection. Diagnostics (Basel) 2024; 14:2179. [PMID: 39410582 PMCID: PMC11475452 DOI: 10.3390/diagnostics14192179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2024] [Revised: 09/26/2024] [Accepted: 09/29/2024] [Indexed: 10/20/2024] Open
Abstract
BACKGROUND/OBJECTIVES The Elecsys® HCV Duo immunoassay (Roche Diagnostics International Ltd., Rotkreuz, Switzerland) detects both antibodies to hepatitis C virus (anti-HCV) and HCV core antigen (HCV-Ag) and has shown excellent diagnostic performance in blood donor samples. We aim to validate its use for diagnosing chronic HCV infection and assessing sustained virological response (SVR) post-direct-acting antivirals (DAAs) in patients with or without HIV infection. METHODS Blood samples from 100 healthy controls, as well as 64 HCV mono-infection and 136 HCV-HIV coinfections, were collected before and 12-24 weeks after DAAs. The assay performance for determining active infection at baseline and SVR was compared with HCV RNA. RESULTS Overall, 156 (78.0%) of HCV-infected patients had HCV genotype 1, and the SVR rate was 96.5%. The sensitivity, specificity, and area under the ROC curve (AUROC) for HCV diagnosis at baseline were 99.50% (95% confidence interval [CI], 96.82-99.97%), 100% (95%CI, 95.39-100%), and 0.998 (95%CI, 0.992-1.003), respectively. The corresponding results for HCV-Ag in determining SVR were 57.14% (95%CI, 20.24-88.19%), 97.41% (95%CI, 93.73-99.04%), and 0.773 (95%CI, 0.543-1.003), respectively. The assay also exhibited comparable sensitivity and specificity between HCV mono- and coinfection. CONCLUSIONS Our study showed that the Elecsys® HCV Duo immunoassay effectively diagnosed HCV infection, regardless of HIV status, making it suitable for managing high-risk populations in resource-limited settings.
Collapse
Affiliation(s)
- Prooksa Ananchuensook
- Division of Gastroenterology, Department of Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand;
- Academic Affair, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand
| | | | - Anchalee Avihingsanon
- The HIV Netherlands Australia Thailand Research Collaboration (HIV-NAT), Bangkok 10330, Thailand;
| | - Pisit Tangkijvanich
- Center of Excellence in Hepatitis and Liver Cancer, Department of Biochemistry, Chulalongkorn University, Bangkok 10330, Thailand
| |
Collapse
|
2
|
Garg J, Verma P, Singh M, Das A, Pathak A, Agarwal J. Hepatitis C virus core antigen: A diagnostic and treatment monitoring marker of hepatitis C virus in Indian population. Indian J Gastroenterol 2024:10.1007/s12664-024-01549-7. [PMID: 38619807 DOI: 10.1007/s12664-024-01549-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2023] [Accepted: 02/01/2024] [Indexed: 04/16/2024]
Abstract
BACKGROUND The diagnosis and treatment monitoring of hepatitis C is quite challenging. The screening test, i.e. antibody assay, is unable to detect acute cases, while the gold standard hepatitis C virus (HCV) reverse transcriptase polymerase chain reaction (RTPCR) assay is not feasible in resource-limited countries such as India due to high cost and infrastructure requirement. European Association for the Study of the Liver and World Health Organization have approved a new marker, i.e. HCV core antigen (HCVcAg) assay, as an alternative to molecular assay. In this study, we have evaluated HCVcAg assay for diagnosis and treatment monitoring follow-up in Indian population infected with hepatitis C. METHODS Blood specimen of 90 clinically suspected cases of acute hepatitis C were tested simultaneously for anti-HCV antibody assay via ELISA (enzyme-linked immunoassay), HCVcAg assay by chemiluminescence immune assay (CLIA) and HCV RTPCR VL (viral load) assay. Thirty-four HCV RTPCR positive patients were further enrolled in treatment monitoring group whose blood samples were tested at the beginning of treatment, two weeks, four weeks and 12 weeks via HCV core Ag assay and HCV RTPCR Viral Load assay. RESULTS Considering HCV RTPCR as gold standard, diagnostic performance of HCV core Ag assay and anti-HCV antibody assay was evaluated. The sensitivity and specificity of HCV core Ag assay were higher than that of anti-HCV Antibody assay, i.e. 88.3% and 100% vs. 23.3% and 83.3%, respectively. The overall diagnostic accuracy of HCV core Ag assay was 92.20%. Among treatment follow-up group, HCV core Ag levels correlated well with HCV viral load levels, at the beginning of treatment (baseline) till 12 weeks showing highly significant Spearman rank correlation coefficient of > 0.9 with HCV viral load levels. CONCLUSIONS HCV core Ag assay is a cost-effective, practically feasible substitute of HCV RTPCR viral load assay for diagnosis as well as long duration treatment monitoring of hepatitis C infection in resource-limited settings.
Collapse
Affiliation(s)
- Jaya Garg
- Department of Microbiology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, 226 010, India.
| | - Prashant Verma
- Department of Gastromedicine, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, 226 010, India
| | - Mridu Singh
- Department of Medicine, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, 226 010, India
| | - Anupam Das
- Department of Microbiology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, 226 010, India
| | - Anurag Pathak
- Department of Community Medicine, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, 226 010, India
| | - Jyotsna Agarwal
- Department of Microbiology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, 226 010, India
| |
Collapse
|
3
|
Sepúlveda-Crespo D, Treviño-Nakoura A, Bellón JM, Fernández-Rodríguez A, Ryan P, Martínez I, Jiménez-Sousa MA, Resino S. Diagnostic performance of hepatitis C core antigen assay to identify active infections: A systematic review and meta-analysis. Rev Med Virol 2023; 33:e2436. [PMID: 36811353 DOI: 10.1002/rmv.2436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 02/10/2023] [Accepted: 02/12/2023] [Indexed: 02/24/2023]
Abstract
Hepatitis C virus (HCV) core antigen (HCVcAg) assay is an alternative for diagnosing HCV infection in a single step. This meta-analysis aimed to evaluate the Abbott ARCHITECT HCV Ag assay's diagnostic performance (validity and utility) for diagnosing active hepatitis C. PubMed, EMBASE, Scopus, Web of Science, and Cochrane Library were searched until 10 January 2023. The protocol was registered at the prospective international register of systematic reviews (PROSPERO: CRD42022337191). Abbott ARCHITECT HCV Ag assay was the test for evaluation, and nucleic acid amplification tests with a cut-off ≤50 IU/mL were the gold standard. Statistical analysis was performed using STATA with the MIDAS module and random-effects models. The bivariate analysis was conducted on 46 studies (18,116 samples). The pooled sensitivity was 0.96 (95% CI = 0.94-0.97), specificity 0.99 (95% CI = 0.99-1.00), positive likelihood ratio 141.81 (95% CI = 72.39-277.79), and negative likelihood ratio 0.04 (95% CI = 0.03-0.06). The area under the summary receiver operating characteristic curve was 1.00 (95% CI = 0.34-1.00). For active hepatitis C prevalence values of 0.1%-15%, the probability that a positive test was a true positive was 12%-96%, respectively, indicating that a confirmatory test should be necessary, particularly with a prevalence ≤5%. However, the probability that a negative test was a false negative was close to zero, indicating the absence of HCV infection. The validity (accuracy) of the Abbott ARCHITECT HCV Ag assay for screening active HCV infection in serum/plasma samples was excellent. Although the HCVcAg assay showed limited diagnostic utility in low prevalence settings (≤1%), it might help diagnose hepatitis C in high prevalence scenarios (≥5%).
Collapse
Affiliation(s)
- Daniel Sepúlveda-Crespo
- Unidad de Infección Viral e Inmunidad, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Spain.,Centro de Investigación Biomédica en Red en Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
| | - Ana Treviño-Nakoura
- Servicio de Medicina Preventiva y Salud Pública, Hospital Universitario Nuestra Señora de la Candelaria, Santa Cruz de Tenerife, Spain.,Universidad Nacional de Educación a Distancia (UNED), Madrid, Spain
| | - José M Bellón
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain
| | - Amanda Fernández-Rodríguez
- Unidad de Infección Viral e Inmunidad, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Spain.,Centro de Investigación Biomédica en Red en Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
| | - Pablo Ryan
- Centro de Investigación Biomédica en Red en Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain.,Servicio de Medicina Interna, Hospital Universitario Infanta Leonor, Madrid, Spain
| | - Isidoro Martínez
- Unidad de Infección Viral e Inmunidad, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Spain.,Centro de Investigación Biomédica en Red en Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
| | - María A Jiménez-Sousa
- Unidad de Infección Viral e Inmunidad, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Spain.,Centro de Investigación Biomédica en Red en Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
| | - Salvador Resino
- Unidad de Infección Viral e Inmunidad, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Spain.,Centro de Investigación Biomédica en Red en Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
| |
Collapse
|
4
|
Diagnostic Performance of the HCV Core Antigen Test To Identify Hepatitis C in HIV-Infected Patients: a Systematic Review and Meta-Analysis. J Clin Microbiol 2023; 61:e0133122. [PMID: 36537787 PMCID: PMC9879113 DOI: 10.1128/jcm.01331-22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
The standard algorithm for diagnosing hepatitis C virus (HCV) infection has two steps, an HCV antibody test for screening and a nucleic acid amplification test (NAAT) for confirmation. However, the HCV core antigen (HCVcAg) detection assay is an alternative for one-step diagnosis. We aimed to evaluate the diagnostic performance of the Abbott ARCHITECT HCV Ag assay to detect active hepatitis C in serum/plasma in people living with HIV/AIDS (PLWHA), through a systematic review and meta-analysis. PubMed, EMBASE, Scopus, Web of Science, and the Cochrane Library were searched until 20 September 2022 (PROSPERO, CRD42022348351). We included studies evaluating Abbott ARCHITECT HCV Ag assay (index assay) versus NAATs (reference test) in PLWHA coinfected with HCV who did not receive antiviral treatment for HCV. Meta-analysis was performed with the MIDAS module using Stata and random-effects models. The QUADAS-2 tool evaluated the risk of bias. The bivariate analysis was conducted on 11 studies with 2,407 samples. Pooled sensitivity was 0.95 (95% CI = 0.92 to 0.97), specificity 0.97 (95% CI = 0.93 to 0.99), positive likelihood ratio 37.76 (95% CI = 12.84 to 111.02), and negative likelihood ratio 0.06 (95% CI = 0.04 to 0.09). The area under the curve was 0.97 (95% CI = 0.20 to 1.00). For low prevalence (≤5%), the posttest probability that an individual with a positive test was a true positive ranged from 4% to 67%, whereas, at high prevalence (≥10%), the posttest probability was between 81% and 87%, indicating that a confirmatory test should be necessary, particularly with prevalence values of ≤1%. Regardless of prevalence, the probability that an individual with a negative test was a false negative was close to zero, indicating that the individual was not infected with HCV. In conclusion, the accuracy of the Abbott ARCHITECT HCV Ag assay was very good for HCV screening in serum/plasma samples from PLWHA. The clinical utility to confirm HCV infection was acceptable in high-prevalence settings (≥10%) but poor in low-prevalence settings (≤1%). Furthermore, it was excellent in excluding active HCV infection.
Collapse
|
5
|
Pusomjit P, Teengam P, Chuaypen N, Tangkijvanich P, Thepsuparungsikul N, Chailapakul O. Electrochemical immunoassay for detection of hepatitis C virus core antigen using electrode modified with Pt-decorated single-walled carbon nanotubes. Mikrochim Acta 2022; 189:339. [PMID: 35982360 DOI: 10.1007/s00604-022-05400-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 07/01/2022] [Indexed: 11/24/2022]
Abstract
Pt nanoparticles deposited on single-walled carbon nanotubes (PtSWCNTs), synthesized via the deposition precipitation (DP) method, were introduced as a substrate for immobilizing antibodies on an electrode surface and then enhancing the electrochemical sensitivity. A PtSWCNT-modified paper-based screen-printed graphene electrode was successfully developed to diagnose hepatitis C virus (HCV) infection. The hepatitis C virus core antigen (HCV-cAg) level was determined by differential pulse voltammetry (DPV) using [Fe(CN)6]3-/4- as a redox solution. In the presence of HCV-cAg, the DPV current response decreased with increasing HCV-cAg concentration. Under the optimal conditions, the change in current response provides a good linear correlation with the logarithm of HCV-cAg concentration in the range 0.05 to 1000 pg mL-1 (RSD < 5%), and the limit of detection was 0.015 pg mL-1 (or 0.71 fmol L-1). Furthermore, the proposed immunosensor has been utilized to quantify HCV-cAg in human serum samples with reliable results compared with standard immunoassays (% relative error < 10%). This sensor offers a simple, sensitive, selective, disposable, and inexpensive means for determination of HCV-cAg in human serum samples. The paper-based label-free immunosensor is versatile and feasible for clinical diagnosis.
Collapse
Affiliation(s)
- Pannaporn Pusomjit
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Chulalongkorn University, Pathumwan, 10330, Bangkok, Thailand
| | - Prinjaporn Teengam
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Chulalongkorn University, Pathumwan, 10330, Bangkok, Thailand
| | - Natthaya Chuaypen
- Center of Excellence in Hepatitis and Liver Cancer, Department of Biochemistry, Faculty of Medicine, Chulalongkorn University, Pathumwan, 10330, Bangkok, Thailand
| | - Pisit Tangkijvanich
- Center of Excellence in Hepatitis and Liver Cancer, Department of Biochemistry, Faculty of Medicine, Chulalongkorn University, Pathumwan, 10330, Bangkok, Thailand
| | - Nichanan Thepsuparungsikul
- Department of Chemistry, Faculty of Science, Silpakorn University, Amphoe Muang, 73000, Nakhon Pathom, Thailand.
| | - Orawon Chailapakul
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Chulalongkorn University, Pathumwan, 10330, Bangkok, Thailand. .,Center of Excellence On Petrochemical and Materials Technology, Chulalongkorn University, Pathumwan, 10330, Bangkok, Thailand.
| |
Collapse
|
6
|
Wang Y, Jie W, Ling J, Yuanshuai H. HCV core antigen plays an important role in the fight against HCV as an alternative to HCV-RNA detection. J Clin Lab Anal 2021; 35:e23755. [PMID: 33788295 PMCID: PMC8183919 DOI: 10.1002/jcla.23755] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2020] [Revised: 02/18/2021] [Accepted: 02/19/2021] [Indexed: 12/22/2022] Open
Abstract
Objective To discuss the clinical significance of HCV‐cAg testing in the diagnosis, activity determination, and monitoring of therapeutic effectiveness of HCV infection and its advantages compared with HCV‐RNA and anti‐HCV antibodies detection. Methods By summarizing the published literature, the advantages and significance of HCV core antigen detection were sought. Results The expression of HCV‐cAg is highly consistent with that of HCV‐RNA, but compared with HCV‐RNA, detection of HCV‐cAg is easy to operate, time saving, and low cost. HCV‐cAg can be detected within 12~15 days after infection, and the window period can be shortened by5~7 weeks. HCV‐cAg is a serological indicator of virus replication, which can distinguish previous infection of HCV or current infection. HCV‐cAg detection is more suitable for immunocompromised, hemodialysis, organ transplant patients. HCV‐cAg also can be used to monitor antiviral efficacy and predict sustained virological response (SVR). Conclusion HCV core antigen has similar clinical sensitivity to NAT and can be used as a substitute for HCV‐RNA in the diagnosis of virus infection. Combined detection of HCV‐cAg and antibody serology can help doctors detect HCV infection earlier, accurately diagnose different stages of HCV infection, and evaluate the therapeutic effect of antiviral drugs, which are beneficial in the prevention and treatment of hepatitis C.
Collapse
Affiliation(s)
- Yuhan Wang
- Department of Transfusion, The Affiliated Hospital of Southwest Medical University, Luzhou, China
| | - Wang Jie
- Department of Transfusion, The Affiliated Hospital of Southwest Medical University, Luzhou, China
| | - Jiang Ling
- Department of Transfusion, The Affiliated Hospital of Southwest Medical University, Luzhou, China
| | - Huang Yuanshuai
- Department of Transfusion, The Affiliated Hospital of Southwest Medical University, Luzhou, China
| |
Collapse
|
7
|
Arribas J, Benito R, Cebollada R, Bellés A, Bueno J, Cumbraos MJ, Gil J. Implications of grey zone results for routine hepatitis C virus screening with the ARCHITECT HCV-Ag assay. J Appl Microbiol 2019; 128:899-906. [PMID: 31713922 DOI: 10.1111/jam.14517] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 10/28/2019] [Accepted: 11/04/2019] [Indexed: 12/14/2022]
Abstract
AIMS Hepatitis C virus antigen (HCV-Ag) detection requires retesting for samples with grey zone results (GzR), adding cost and time and decreasing reliability. Our aim in this study was to evaluate the frequency and significance of GzR during the use of the automated Architect HCV-Ag assay in routine clinical practice. METHODS AND RESULTS We studied HCV-Ag levels in 952 serum samples using the ARCHITECT HCV-Ag assay. GzR were detected in 33 samples; 25 were reactive on retesting and 19 were anti-HCV positive. Seventeen of these 19 samples were tested for HCV-RNA and were all reactive (viral loads <104 IU ml-1 ). The remaining six samples were anti-HCV nonreactive and had undetectable HCV-RNA. Eight GzR samples were nonreactive on retesting, seven were anti-HCV nonreactive (three underwent HCV-RNA quantification and were all nonreactive), and one was anti-HCV reactive (HCV-RNA nonreactive). No significant differences were found on comparing HCV-Ag values. CONCLUSIONS Grey zone results found to be negative on retesting do not need additional technique testing, except in donor screening scenarios, where the use of molecular methods would be advisable. SIGNIFICANCE AND IMPACT OF THE STUDY The proposed diagnostic algorithm confirms that, eventhough GzR occur, hepatitis C virus antigen is a robust alternative to HCV-RNA detection in the active detection of infections.
Collapse
Affiliation(s)
- J Arribas
- Service of Microbiology, Hospital Clínico Universitario Lozano Blesa, Zaragoza, Spain
| | - R Benito
- Service of Microbiology, Hospital Clínico Universitario Lozano Blesa, Zaragoza, Spain.,Department of Microbiology, University of Zaragoza, Zaragoza, Spain
| | - R Cebollada
- Service of Microbiology, Hospital Clínico Universitario Lozano Blesa, Zaragoza, Spain
| | - A Bellés
- Service of Microbiology, Hospital Clínico Universitario Lozano Blesa, Zaragoza, Spain
| | - J Bueno
- Service of Microbiology, Hospital Clínico Universitario Lozano Blesa, Zaragoza, Spain
| | - M J Cumbraos
- Service of Pharmacy, Hospital Clínico Universitario Lozano Blesa, Zaragoza, Spain
| | - J Gil
- Service of Microbiology, Hospital Clínico Universitario Lozano Blesa, Zaragoza, Spain.,Department of Microbiology, University of Zaragoza, Zaragoza, Spain
| |
Collapse
|