1
|
Debnath SBC, Tonneau D, Fauquet C, Tallet A, Darréon J. Cerenkov free micro-dosimetry in small-field radiation therapy technique. Phys Med Biol 2024; 69:125018. [PMID: 38810619 DOI: 10.1088/1361-6560/ad51c6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Accepted: 05/29/2024] [Indexed: 05/31/2024]
Abstract
Objective. Optical fiber-based scintillating dosimetry is a recent promising technique owing to the miniature size dosimeter and quality measurement in modern radiation therapy treatment. Despite several advantages, the major issue of using scintillating dosimeters is the Cerenkov effect and predominantly requires extra measurement corrections. Therefore, this work highlighted a novel micro-dosimetry technique to ensure Cerenkov-free measurement in radiation therapy treatment protocol by investigating several dosimetric characteristics.Approach.A micro-dosimetry technique was proposed with the performance evaluation of a novel infrared inorganic scintillator detector (IR-ISD). The detector essentially consists of a micro-scintillating head based on IR-emitting micro-clusters with a sensitive volume of 1.5 × 10-6mm3. The proposed system was evaluated under the 6 MV LINAC beam used in patient treatment. Overall measurements were performed using IBATMwater tank phantoms by following TRS-398 protocol for radiotherapy. Cerenkov measurements were performed for different small fields from 0.5 × 0.5 cm2to 10 × 10 cm2under LINAC. In addition, several dosimetric parameters such as percentage depth dose (PDD), high lateral resolution beam profiling, dose linearity, dose rate linearity, repeatability, reproducibility, and field output factor were investigated to realize the performance of the novel detector.Main results. This study highlighted a complete removal of the Cerenkov effect using a point-like miniature detector, especially for small field radiation therapy treatment. Measurements demonstrated that IR-ISD has acceptable behavior with dose rate variability (maximum standard deviation ∼0.18%) for the dose rate of 20-1000 cGy s-1. An entire linear response (R2= 1) was obtained for the dose delivered within the range of 4-1000 cGy, using a selected field size of 1 × 1 cm2. Perfect repeatability (max 0.06% variation from average) with day-to-day reproducibility (0.10% average variation) was observed. PDD profiles obtained in the water tank present almost identical behavior to the reference dosimeter with a build-up maximum depth dose at 1.5 cm. The small field of 0.5 × 0.5 cm2profiles have been characterized with a high lateral resolution of 100µm.Significance. Unlike recent plastic scintillation detector systems, the proposed micro-dosimetry system in this study requires no Cerenkov corrections and showed efficient performance for several dosimetric parameters. Therefore, it is expected that considering the detector correction factors, the IR-ISD system can be a suitable dose measurement tool, such as in small-field dose measurements, high and low gradient dose verification, and, by extension, in microbeam radiation and FLASH radiation therapy.
Collapse
Affiliation(s)
- Sree Bash Chandra Debnath
- Aix-Marseille University, CNRS, LP3 UMR 7341, 13288 Marseille, France
- Aix Marseille University, CNRS, CINaM UMR 7325, Marseille, 13288, France
| | - Didier Tonneau
- Aix Marseille University, CNRS, CINaM UMR 7325, Marseille, 13288, France
| | - Carole Fauquet
- Aix Marseille University, CNRS, CINaM UMR 7325, Marseille, 13288, France
| | - Agnes Tallet
- Institut Paoli-Calmettes, 13009 Marseille, France
| | | |
Collapse
|
2
|
Wahabi JM, Wong JHD, Mahdiraji GA, Ung NM. Feasibility of determining external beam radiotherapy dose using LuSy dosimeter. J Appl Clin Med Phys 2024; 25:e14387. [PMID: 38778567 PMCID: PMC11163501 DOI: 10.1002/acm2.14387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 04/20/2024] [Accepted: 04/26/2024] [Indexed: 05/25/2024] Open
Abstract
INTRODUCTION Radiation dose measurement is an essential part of radiotherapy to verify the correct delivery of doses to patients and ensure patient safety. Recent advancements in radiotherapy technology have highlighted the need for fast and precise dosimeters. Technologies like FLASH radiotherapy and magnetic-resonance linear accelerators (MR-LINAC) demand dosimeters that can meet their unique requirements. One promising solution is the plastic scintillator-based dosimeter with high spatial resolution and real-time dose output. This study explores the feasibility of using the LuSy dosimeter, an in-house developed plastic scintillator dosimeter for dose verification across various radiotherapy techniques, including conformal radiotherapy (CRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). MATERIALS AND METHODS A new dosimetry system, comprising a new plastic scintillator as the sensing material, was developed and characterized for radiotherapy beams. Treatment plans were created for conformal radiotherapy, IMRT, VMAT, and SRS and delivered to a phantom. LuSy dosimeter was used to measure the delivered dose for each plan on the surface of the phantom and inside the target volumes. Then, LuSy measurements were compared against an ionization chamber, MOSFET dosimeter, radiochromic films, and dose calculated using the treatment planning system (TPS). RESULTS For CRT, surface dose measurement by LuSy dosimeter showed a deviation of -5.5% and -5.4% for breast and abdomen treatment from the TPS, respectively. When measuring inside the target volume for IMRT, VMAT, and SRS, the LuSy dosimeter produced a mean deviation of -3.0% from the TPS. Surface dose measurement resulted in higher TPS discrepancies where the deviations for IMRT, VMAT, and SRS were -2.0%, -19.5%, and 16.1%, respectively. CONCLUSION The LuSy dosimeter was feasible for measuring radiotherapy doses for various treatment techniques. Treatment delivery verification enables early error detection, allowing for safe treatment delivery for radiotherapy patients.
Collapse
Affiliation(s)
- Janatul Madinah Wahabi
- Department of Biomedical ImagingFaculty of MedicineUniversiti MalayaKuala LumpurMalaysia
- Radiotherapy and Oncology DepartmentNational Cancer InstitutePutrajayaMalaysia
| | - Jeannie Hsiu Ding Wong
- Department of Biomedical ImagingFaculty of MedicineUniversiti MalayaKuala LumpurMalaysia
- Universiti Malaya Research Imaging Centre (UMRIC), Faculty of MedicineUniversiti MalayaKuala LumpurMalaysia
| | | | - Ngie Min Ung
- Clinical Oncology UnitFaculty of MedicineUniversiti MalayaKuala LumpurMalaysia
| |
Collapse
|
3
|
Tahmasbi M, Capela M, Santos T, Mateus J, Ventura T, do Carmo Lopes M. Particular issues to be considered in small field dosimetry for TrueBeam STx commissioning. Appl Radiat Isot 2023; 202:111066. [PMID: 37865066 DOI: 10.1016/j.apradiso.2023.111066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 08/28/2023] [Accepted: 10/05/2023] [Indexed: 10/23/2023]
Abstract
This study aims to report the relevant issues concerning small fields in the commissioning of a TrueBeam STx for photon energies of 6MV, 10MV, 6FFF, and 10FFF. Percent depth doses, profiles, and field output factors were measured according to the beam model configuration of the treatment planning system. Multiple detectors were used based on the IAEA TRS-483 protocol as well as EBT3 radiochromic film. Analytical Anisotropic and Acuros XB algorithms, were configured and validated through basic dosimetry comparisons and end-to-end clinical tests.
Collapse
Affiliation(s)
- Marziyeh Tahmasbi
- Radiologic Technology Department, School of Allied Medical Sciences, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran; Medical Physics Department, Instituto Portugues de Oncologia Coimbra Francisco Gentil, E.P.E., Portugal.
| | - Miguel Capela
- Medical Physics Department, Instituto Portugues de Oncologia Coimbra Francisco Gentil, E.P.E., Portugal
| | - Tania Santos
- Medical Physics Department, Instituto Portugues de Oncologia Coimbra Francisco Gentil, E.P.E., Portugal
| | - Josefina Mateus
- Medical Physics Department, Instituto Portugues de Oncologia Coimbra Francisco Gentil, E.P.E., Portugal
| | - Tiago Ventura
- Medical Physics Department, Instituto Portugues de Oncologia Coimbra Francisco Gentil, E.P.E., Portugal
| | - Maria do Carmo Lopes
- Medical Physics Department, Instituto Portugues de Oncologia Coimbra Francisco Gentil, E.P.E., Portugal
| |
Collapse
|
4
|
Kojima H, Ishikawa M, Takigami M. Technical note: Point-by-point ion-recombination correction for accurate dose profile measurement in high dose-per-pulse irradiation field. Med Phys 2023; 50:7281-7293. [PMID: 37528637 DOI: 10.1002/mp.16641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 07/13/2023] [Accepted: 07/14/2023] [Indexed: 08/03/2023] Open
Abstract
BACKGROUND Although flattening filter free (FFF) beams are commonly used in clinical treatment, the accuracy of dose measurements in FFF beams has been questioned. Higher dose per pulse (DPP) such as FFF beams from a linear accelerator may cause problems in dose profile measurements using an ionization chamber due to the change of the charge collection efficiency. Ionization chambers are commonly used for percent depth dose (PDD) measurements. Changes of DPP due to chamber movement during PDD measurement can vary the ion collection efficiency of ionization chambers. In the case of FF beams, the DPP fluctuation is negligible, but in the case of the FFF beams, the DPP is 2.5 ∼ 4 times larger than that of the FF beam, and the change in ion collection efficiency is larger than that of the FF beam. PDD profile normalized by maximum dose depth, 10 cm depth for example, may therefore be affected by the ion collection efficiency. PURPOSE In this study, we investigate the characteristics of the ion collection efficiency change depending on the DPP of each ionization chamber in the FFF beam. We furthermore propose a method to obtain the chamber- independent PDD by applying a DPP-dependent ion recombination correction. METHODS Prior to investigating the relationship between DPP and charge collection efficiency, Jaffe-plots were generated with different DPP settings to investigate the linearity between the applied voltage and collected charge. The absolute dose measurement using eight ionization chambers under the irradiation settings of 0.148, 0.087, and 0.008 cGy/pulse were performed. Applied voltages for the Jaffe-plots were 100, 125, 150, 200, 250, and 300 V. The ion recombination correction factor Pion was calculated by the two-voltage analysis (TVA) method at the applied voltages of 300 and 100 V. The DPP dependency of the charge collection efficiency for each ionization chamber were evaluated from the DPP- Pion plot. PDD profiles for the 10 MV FFF beam were measured using Farmer type chambers (TN30013, FC65-P, and FC65-G) and mini-type chambers (TN31010, TN31021, CC13, CC04, and FC23-C). The PDD profiles were corrected with ion recombination correction at negative and positive polar applied voltages of 100 and 300 V. RESULTS From the DPP-Pion relation for each ionization chamber with DPP ranging from 0.008 cGy/pulse to 0.148 cGy/pulse, all Farmer and mini-type chambers satisfied the requirements described in AAPM TG-51 addendum. However, Pion for the CC13 was most affected by DPP among tested chambers. The maximum deviation among PDDs using eight ionization chambers for 10 MV FFF was about 1%, but the deviation was suppressed to about 0.5% by applying ion recombination correction at each depth. CONCLUSIONS In this study, the deviation of PDD profile among the ionization chambers was reduced by the ion recombination coefficient including the DPP dependency, especially for high DPP beams such as FFF beams. The present method is particularly effective for CC13, where the ion collection efficiency is highly DPP dependent.
Collapse
Affiliation(s)
- Hideki Kojima
- Department of Radiation Oncology, Sapporo Higashi Tokushukai Hospital, Sapporo, Hokkaido, Japan
| | - Masayori Ishikawa
- Faculty of Health Sciences, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Makoto Takigami
- Department of Radiation Technology, KKR Sapporo Medical Center, Sapporo, Hokkaido, Japan
| |
Collapse
|
5
|
Timakova E, Bazalova-Carter M, Zavgorodni S. Characterization of a 0.8 mm 3Medscint plastic scintillator detector system for small field dosimetry. Phys Med Biol 2023; 68:175040. [PMID: 37494941 DOI: 10.1088/1361-6560/aceacf] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Accepted: 07/25/2023] [Indexed: 07/28/2023]
Abstract
Objective. Plastic scintillator detectors (PSDs) have demonstrated ability to meet requirements of small field dosimetry. Medscint developed a 1 mm long, 1 mm diameter cylindrical PSD with effective volume of 0.8 mm3. Clinically relevant, small field dosimetric properties of this detector, combined with a novel scintillation dosimetry system-HYPERSCINT RP-200, and HYPERDOSE analysis software were evaluated in this study.Approach. This novel scintillator-based dosimetry system was characterized with 6 MV-WFF and 10 MV-FFF x-ray beams delivered by Varian TrueBeamTMlinear accelerator. The detector was characterized for leakage, short-term repeatability, dose response linearity, angular response, dose rate response, and field size dependence for radiation field sizes of 0.25 × 0.25 to 10 × 10 cm2. Measured detector specific output ratios were compared with microDiamond output factors to determine small field output correction factors,kQclin,Qmsrfclin,fmsr.Main results. The dosimetry system showed excellent short-term repeatability with standard deviation of only 0.04 ± 0.01%. It demonstrated good dose linearity with variations less than 1.0% for 14.4 cGy and above. The dosimetry system was found to be independent of dose rate and angle of irradiation, with deviations for both below 0.5%. Leakage was found to be comparable to background readings. For 6 MV-WFF energy beams, detector specific output ratios for field sizes down to 1 × 1 cm2agreed with output factors measured with PTW TN60019 microDiamond, thus,kQclin,Qmsrfclin,fmsrequates to unity for these field sizes. For 10 MV-FFF energy beams, detector specific output ratios for field sizes down to 2 × 2 cm2agreed with PTW TN60019 microDiamond output factors, thus,kQclin,Qmsrfclin,fmsrequates to unity for these field sizes.kQclin,Qmsrfclin,fmsrfor field sizes down to 0.5 × 0.5 cm2were determined to be within 6% of unity for both 6 MV-WFF and 10 MV-FFF energy beams.Significance. The HYPERSCINT RP-200 dosimetry system coupled with a 0.8 mm3PSD showed excellent dosimetric properties and was found to be clinically relevant for relative dosimetry down to field sizes of 0.5 × 0.5 cm2and potentially smaller.
Collapse
Affiliation(s)
- Elena Timakova
- University of Victoria, British Columbia, Canada
- BC Cancer Agency, Vancouver Island Centre, British Columbia, Canada
| | | | - Sergei Zavgorodni
- University of Victoria, British Columbia, Canada
- BC Cancer Agency, Vancouver Island Centre, British Columbia, Canada
| |
Collapse
|
6
|
Yoshitani H, Fujibuchi T, Anam C. Visualization of dose distribution and basic study of dose estimation using plastic scintillator and digital camera. Biomed Phys Eng Express 2022; 8. [PMID: 35764067 DOI: 10.1088/2057-1976/ac7c91] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 06/28/2022] [Indexed: 11/11/2022]
Abstract
Radiation can be visualized using a scintillator and a digital camera. If the amount of light emitted by the scintillator increases with dose, the dose estimation can be obtained from the amount of light emitted. In this study, the basic performance of the scintillator and digital camera system was evaluated by measuring computed tomography dose index (CTDI). A circular plastic scintillator plate was sandwiched between polymethyl methacrylate (PMMA) phantoms, and X-rays were irradiated to them while rotating the X-ray tube to confirm changes in light emission. In addition, CTDI was estimated from the amount of light emitted by the scintillator during the helical scan and compared with the value measured from dosimeter. The scintillator emitted light while changing its distribution according to the movement of the X-ray tube. The measured CTDIvol was 33.20 mGy, the CTDIvol estimated from the scintillation light was approximately 46 mGy, which was 40% larger. In particular, when the scintillator was directly irradiated, the dose was overestimated compared with the value measured from the dosimeter. This overestimation can be because of the reproducibility of the position and the difference between the sensitivity of the scintillator to detect light emission and the sensitivity of the dosimeter, and the non-uniformity of position sensitivity due to the wide-angle lens.
Collapse
Affiliation(s)
- Hiroshi Yoshitani
- Department of Health Sciences, Kyushu University, Fukuoka, Fukuoka, 812-8582, JAPAN
| | - Toshioh Fujibuchi
- Department of Health Sciences, Kyushu University, Fukuoka, Fukuoka, 819-0395, JAPAN
| | - Choirul Anam
- Department of Physics, Universitas Diponegoro, Jl. Prof Soedarto, Tembalang, Semarang, Central Java, 50275, INDONESIA
| |
Collapse
|