1
|
La Verde M, Riemma G, Torella M, Torre C, Cianci S, Conte A, Capristo C, Morlando M, Colacurci N, De Franciscis P. Impact of Braxton-Hicks contractions on fetal wellbeing; a prospective analysis through computerised cardiotocography. J OBSTET GYNAECOL 2021; 42:569-573. [PMID: 34396910 DOI: 10.1080/01443615.2021.1929115] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
To estimate the correlation between the maternal perception of Braxton-Hicks contractions (BHC) and foetal wellbeing throughout antepartum computerised cardiotocography (cCTG) parameters, we performed a prospective observational study between April 2019 and March 2020. Non-labouring women with a term pregnancy were recruited. We collected data regarding maternal perception of BHC in the last two weeks before delivery. For each patient, an external computerised cardiotocography (cCTG) was registered. Women were subdivided in accordance with perception or non-perception of BHC. Fifty women were recruited. Women who felt BHC showed higher foetal heart rate (135 bpm vs 128 bpm, p = .008), lower long-term variability (47.2 ms vs 57.7 ms, p = .02) and reduced number of accelerations (7.8 vs 11.4, p = .04). In conclusion, the absence of mother's perception of BHC showed lower baseline foetal heart rate, increased number of accelerations and higher long-term variability related to mothers who perceived BHC.IMPACT STATEMENTWhat is already known on this subject? BHC are common painful contractions that start in the third trimester. They are random spots of uterine action that happen in the absence of sufficient gap-junction connectivity. BHC have a significant impact on foetal wellbeing.What do the results of this study add? BHC are associated with reduced long-term variability during cCTG examination. Moreover, baseline foetal heart rate seems lower, and accelerations are less frequent when BHC are felt by pregnant women.What are the implications of these findings for clinical practice and/or further research? These findings could be related to a cumulative effect on the uterine flow mediated by BHC. Further researches are needed to state the impact of BHC on the foetal wellbeing.
Collapse
Affiliation(s)
- Marco La Verde
- Department of Woman, Child and General and Specialized Surgery, Obstetrics and Gynecology Unit, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Gaetano Riemma
- Department of Woman, Child and General and Specialized Surgery, Obstetrics and Gynecology Unit, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Marco Torella
- Department of Woman, Child and General and Specialized Surgery, Obstetrics and Gynecology Unit, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Clelia Torre
- Department of Woman, Child and General and Specialized Surgery, Obstetrics and Gynecology Unit, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Stefano Cianci
- Department of Woman, Child and General and Specialized Surgery, Obstetrics and Gynecology Unit, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Anna Conte
- Department of Woman, Child and General and Specialized Surgery, Obstetrics and Gynecology Unit, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Carlo Capristo
- Department of Pediatrics, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Maddalena Morlando
- Department of Woman, Child and General and Specialized Surgery, Obstetrics and Gynecology Unit, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Nicola Colacurci
- Department of Woman, Child and General and Specialized Surgery, Obstetrics and Gynecology Unit, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Pasquale De Franciscis
- Department of Woman, Child and General and Specialized Surgery, Obstetrics and Gynecology Unit, University of Campania "Luigi Vanvitelli", Naples, Italy
| |
Collapse
|
2
|
Pels A, Mensing van Charante NA, Vollgraff Heidweiller-Schreurs CA, Limpens J, Wolf H, de Boer MA, Ganzevoort W. The prognostic accuracy of short term variation of fetal heart rate in early-onset fetal growth restriction: A systematic review. Eur J Obstet Gynecol Reprod Biol 2019; 234:179-184. [PMID: 30710764 DOI: 10.1016/j.ejogrb.2019.01.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Accepted: 01/03/2019] [Indexed: 12/01/2022]
Abstract
OBJECTIVE Cardiotocography (CTG) is an important tool for fetal surveillance in severe early-onset fetal growth restriction (FGR). Assessment of the CTG is usually performed visually (vCTG). However, it is suggested that computerized analysis of the CTG (cCTG) including short term variability (STV) could more accurately detect fetal compromise. The objective of this study was to systematically review the literature on the association between cCTG and perinatal outcome and the comparison of cCTG with vCTG. STUDY DESIGN A systematic search was performed in MEDLINE, EMBASE and Google Scholar. Studies were included that assessed prognostic accuracy of STV or compared STV to vCTG in patients with FGR. Risk of bias and concerns about applicability were assessed with the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) instrument. RESULTS Of the 885 records identified in the search, five cohort studies (387 patients) were included. We found no randomized studies comparing STV with visual CTG in patients with FGR. The risk of bias of all studies was generally judged as 'low'. One small study found an association of low STV with neonatal acidosis. One study observed no association of STV with long-term outcome. Composite analysis of all five studies showed a non-significant relative risk for acidosis after a low STV of 1.4 (95% CI 0.6-3.2, N = 387). Further meta-analysis was hampered due to heterogeneity in outcome reporting and use of different thresholds. CONCLUSION The evidence from the included studies did not support an association of STV and short or long term outcome. However, available data are limited and heterogeneous, and influenced by management based on STV. Solid evidence from a randomized controlled trial comparing STV with vCTG including long term infant outcome is needed before STV can be used clinically for timing of delivery in patients with FGR.
Collapse
Affiliation(s)
- A Pels
- Amsterdam UMC, University of Amsterdam, Department of Obstetrics and Gynecology, Meibergdreef 9, Amsterdam, the Netherlands.
| | - N A Mensing van Charante
- Amsterdam UMC, University of Amsterdam, Department of Obstetrics and Gynecology, Meibergdreef 9, Amsterdam, the Netherlands
| | | | - J Limpens
- Amsterdam UMC, University of Amsterdam, Medical Library, Meibergdreef 9, Amsterdam, the Netherlands
| | - H Wolf
- Amsterdam UMC, University of Amsterdam, Department of Obstetrics and Gynecology, Meibergdreef 9, Amsterdam, the Netherlands
| | - M A de Boer
- Amsterdam UMC, Vrije Universiteit Amsterdam, Department of Obstetrics and Gynecology, De Boelelaan 1117, Amsterdam, the Netherlands
| | - W Ganzevoort
- Amsterdam UMC, University of Amsterdam, Department of Obstetrics and Gynecology, Meibergdreef 9, Amsterdam, the Netherlands
| |
Collapse
|
3
|
Mwansa JC, Tambwe AM, Thaba JN, Ndoudule AM, Museba BY, Thabu TM, Muenze PK. [Study of fetal heart rate abnormalities observed on cardiotocography in Lubumbashi: about a cases followed at the Lubumbashi University Clinic and the General Hospital of the Cinquantenaire]. Pan Afr Med J 2018; 30:278. [PMID: 30637063 PMCID: PMC6317385 DOI: 10.11604/pamj.2018.30.278.13365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2017] [Accepted: 07/22/2018] [Indexed: 12/03/2022] Open
Abstract
Cardiotocography (CTG) has recently come into use in Lubumbashi but no thorough study has yet been conducted to identify its impact on perinatal morbi-mortality. This study aims to determine the frequency of fetal heart rate abnormalities (FHR)in order to identify the associated factors and to propose a suitable management. We conducted a cross-sectional, descriptive study of 411 women in labour over a period of 19 months (March 2015-December 2016). In patients with pathologic FHR abnormalities, sensitivity and positive predictive value of cardiotocography in the screening test for acute fetal distress were 82.95% and 45.35% respectively. FHR abnormalities were found in two women in labour out of five. Decelerations were the most frequent FHR abnormalities observed (50.8%) with a remarkable predominance of late decelerations (22.1% of all abnormalities). The factors associated with pathological FHR abnormalities were prolonged labor (OR = 14.64, CI = 3.91-54.81), chorioamnionitis (OR = 14.56, CI = 3.83-55.34), chronic maternal anemia (OR = 4.99, CI = 1.48-16.85), primiparity (OR = 2.69, CI = 1.49-4.85), prematurity (OR = 2.90, CI = 1.51-5.54) and prolonged pregnancy (OR = 3.22, CI = 1.38-7.52). Intrauterine growth retardation and arterial hypertension were mainly associated with flat lines and late decelerations (OR = 7.79, CI = 2.50-24.30 and OR=2.74, CI = 1.31-5.72). CTG is a screening tool for the identification of acute fetal distress but with high false-positive rate (55%); it should be associated with other second-line screening tests for acute fetal distress in order to reduce this rate. Factors associated with pathologic FHR abnormalities often cause acute fetal distress thus requiring a rigorous analysis of CTG traces.
Collapse
Affiliation(s)
- Joseph Chola Mwansa
- Département de Gynécologie-Obstétrique de la Faculté de Médecine de l'Université de Lubumbashi, Republique Démocratique du Congo
- Service de Gynécologie-Obstétrique de l'Hôpital Général du Cinquantenaire Karavia, Lubumbashi, Republique Démocratique du Congo
| | - Albert Mwembo Tambwe
- Département de Gynécologie-Obstétrique de la Faculté de Médecine de l'Université de Lubumbashi, Republique Démocratique du Congo
| | - Jules Ngwe Thaba
- Département de Gynécologie-Obstétrique de la Faculté de Médecine de l'Université de Lubumbashi, Republique Démocratique du Congo
| | - Arthur Munkana Ndoudule
- Département de Gynécologie-Obstétrique de la Faculté de Médecine de l'Université de Lubumbashi, Republique Démocratique du Congo
| | - Baudouin Yumba Museba
- Service de Gynécologie-Obstétrique de l'Hôpital Général du Cinquantenaire Karavia, Lubumbashi, Republique Démocratique du Congo
| | - Thérèse Mowa Thabu
- Service de Gynécologie-Obstétrique de l'Hôpital Général du Cinquantenaire Karavia, Lubumbashi, Republique Démocratique du Congo
| | - Prosper Kalenga Muenze
- Département de Gynécologie-Obstétrique de la Faculté de Médecine de l'Université de Lubumbashi, Republique Démocratique du Congo
- Service de Gynécologie-Obstétrique de l'Hôpital Général du Cinquantenaire Karavia, Lubumbashi, Republique Démocratique du Congo
| |
Collapse
|
4
|
Kapaya H, Jacques R, Anumba D. Comparison of diurnal variations, gestational age and gender related differences in fetal heart rate (FHR) parameters between appropriate-for-gestational-age (AGA) and small-for-gestational-age (SGA) fetuses in the home environment. PLoS One 2018. [PMID: 29522541 PMCID: PMC5844551 DOI: 10.1371/journal.pone.0193908] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Objective To assess the influence of gender, time of the day and gestational age on fetal heart rate (FHR) parameters between appropriate-for-gestational-age (AGA) and small-for-gestational age (SGA) fetuses using a portable fetal ECG monitor employed in the home setting. Methods We analysed and compared the antenatal FHR data collected in the home setting on 61 healthy pregnant women with singleton pregnancies from 24 weeks gestation. Of the 61 women, 31 had SGA fetuses (estimated fetal weight below the tenth gestational centile) and 30 were pregnant with AGA fetuses. FHR recordings were collected for up to 20 h. Two 90 min intervals were deliberately chosen retrospectively with respect to signal recording quality, one during day-time and one at night-time for comparison. Results Overall, success rate of the fetal abdominal ECG in the AGA fetuses was 75.7% compared to 48.6% in the SGA group. Based on randomly selected episodes of heart rate traces where recording quality exceeded 80% we were able to show a marginal difference between day and night-time recordings in AGA vs. SGA fetuses beyond 32 weeks of gestation. A selection bias in terms of covering different representation periods of fetal behavioural states cannot be excluded. In contrast to previous studies, we neither controlled maternal diet and activity nor measured maternal blood hormone and heart rate as all mothers were monitored in the home environment. Conclusion Based on clinically unremarkable, but statistically significant differences in the FHR parameters between the AGA and SGA group we suggest that further studies with large sample size are required to assess the clinical value of antenatal fetal ECG monitoring.
Collapse
Affiliation(s)
- Habiba Kapaya
- Department of Oncology and Metabolism, Academic Unit of Reproductive & Developmental Medicine, The University of Sheffield, Sheffield, United Kingdom
- * E-mail:
| | - Richard Jacques
- Medical Statistics Group, School of Health and Related Research (ScHARR), University of Sheffield, Sheffield, United Kingdom
| | - Dilly Anumba
- Department of Oncology and Metabolism, Academic Unit of Reproductive & Developmental Medicine, The University of Sheffield, Sheffield, United Kingdom
| |
Collapse
|
5
|
Young BK. Antepartum care. J Perinat Med 2017; 45:395-397. [PMID: 28599398 DOI: 10.1515/jpm-2017-0047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
6
|
Amorim-Costa C, Gaio AR, Ayres-de-Campos D, Bernardes J. Longitudinal changes of cardiotocographic parameters throughout pregnancy: a prospective cohort study comparing small-for-gestational-age and normal fetuses from 24 to 40 weeks. J Perinat Med 2017; 45:493-501. [PMID: 27474837 DOI: 10.1515/jpm-2016-0065] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Accepted: 06/03/2016] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To compare longitudinal trends of cardiotocographic (CTG) parameters between small-for-gestational-age (SGA) and normal fetuses, from 24 to 41 weeks of pregnancy. METHODS A prospective cohort study was carried out in singleton pregnancies without fetal malformations. At least one CTG was performed in each of the following intervals: 24-26 weeks+6 days, 27-29 weeks+6 days, 30-32 weeks+6 days, 33-35 weeks+6 days, 36-38 weeks+6 days and ≥39 weeks. Tracings were analyzed using the Omniview-SisPorto® 3.6 system. Cases with a normal pregnancy outcome, including a birthweight ≥10th percentile for gestational age, were compared with two groups of SGA fetuses: with birthweight <10th percentile (SGA<p10) and <3rd percentile (SGA<p3; a subgroup of the latter). Generalized linear mixed-effects models were used for analysis. RESULTS A total of 176 fetuses (31 SGA) and 1256 tracings (207 from SGA fetuses) were evaluated. All CTG parameters changed significantly throughout pregnancy in the three groups, with a decreasing baseline and probability of decelerations, and an increasing average long-term variability (LTV), average short-term variability (STV) and accelerations. Baseline showed a more pronounced decrease (steeper slope) in SGA fetuses, being higher in these cases at earlier gestational ages and lower later in pregnancy. Average LTV was significantly lower in SGA<p3 fetuses, but a parallel increase occurred in all groups. There was a considerable inter-fetal variability within each group. CONCLUSION A unique characterization of CTG trends throughout gestation in SGA fetuses was provided. A steeper descent of the baseline was reported for the first time. The findings raise the possibility of clinical application of computerized CTG analysis in screening and management of fetal growth restriction.
Collapse
|
7
|
Amorim-Costa C, de Campos DA, Bernardes J. Cardiotocographic parameters in small-for-gestational-age fetuses: How do they vary from normal at different gestational ages? A study of 11687 fetuses from 25 to 40 weeks of pregnancy. J Obstet Gynaecol Res 2017; 43:476-485. [PMID: 28165176 DOI: 10.1111/jog.13235] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Revised: 09/16/2016] [Accepted: 10/07/2016] [Indexed: 11/26/2022]
Abstract
AIM The aim of this study was to assess how cardiotocographic (CTG) parameters differ between small-for-gestational-age (SGA) and normal fetuses at different gestational ages. METHODS This was a retrospective cross-sectional study using the first antepartum tracing of singleton pregnancies with no malformations. Fetuses with birthweight ≥10th percentile for gestational age and other normal pregnancy outcome criteria (term birth, normal umbilical artery pH and Apgar scores, no intensive care unit admission) were compared with fetuses with birthweight <10th and <3rd percentiles for gestational age (SGA < p10 and SGA < p3, a subgroup of the latter). Each CTG parameter was compared, by gestational age, using both statistical tests and percentile curves derived from normal outcome cases. Tracings were analyzed with the OmniviewSisPorto® 3.7 system. RESULTS A total of 11 687 tracings (from the same number of fetuses) were analyzed: 9701 normal, 1986 SGA < p10, and 543 SGA < p3. SGA fetuses had lower long- and short-term variability, and number of accelerations, with more pronounced differences between around 28 and 35 weeks. In contrast, baseline was lower in SGA fetuses from 34 weeks onwards. All differences were more pronounced for SGA < p3 fetuses. Similar trends throughout gestation occurred in all groups: decrease in baseline, and increase in long- and short-term variability, and accelerations. CONCLUSIONS This study represents an important step for accurate CTG interpretation in SGA fetuses and, consequently, management of fetal growth restriction (FGR), as it contributes to differentiate between maturational CTG changes that occur physiologically throughout pregnancy, and possible signs of fetal compromise in FGR.
Collapse
Affiliation(s)
- Célia Amorim-Costa
- Department of Obstetrics and Gynecology, Medical School, University of Porto, Porto, Portugal.,Institute for Research and Innovation in Health (Instituto de Investigação e Inovação em Saúde - I3S) and Institute of Biomedical Engineering (Instituto de Engenharia Biomédica - INEB), University of Porto, Portugal.,Center for Research in Health Technologies and Information Systems (CINTESIS), Porto Medical School, University of Porto, Porto, Portugal
| | - Diogo Ayres de Campos
- Department of Obstetrics and Gynecology, Medical School, University of Porto, Porto, Portugal.,Institute for Research and Innovation in Health (Instituto de Investigação e Inovação em Saúde - I3S) and Institute of Biomedical Engineering (Instituto de Engenharia Biomédica - INEB), University of Porto, Portugal.,Center for Research in Health Technologies and Information Systems (CINTESIS), Porto Medical School, University of Porto, Porto, Portugal.,Department of Obstetrics and Gynecology, S. João Hospital, Porto, Portugal
| | - João Bernardes
- Department of Obstetrics and Gynecology, Medical School, University of Porto, Porto, Portugal.,Institute for Research and Innovation in Health (Instituto de Investigação e Inovação em Saúde - I3S) and Institute of Biomedical Engineering (Instituto de Engenharia Biomédica - INEB), University of Porto, Portugal.,Center for Research in Health Technologies and Information Systems (CINTESIS), Porto Medical School, University of Porto, Porto, Portugal.,Department of Obstetrics and Gynecology, S. João Hospital, Porto, Portugal.,Department of Obstetrics and Gynecology, Hospital Pedro Hispano, Matosinhos, Portugal
| |
Collapse
|
8
|
Kapaya H, Jacques R, Rahaim N, Anumba D. "Does short-term variation in fetal heart rate predict fetal acidaemia?" A systematic review and meta-analysis. J Matern Fetal Neonatal Med 2016; 29:4070-7. [PMID: 26902464 DOI: 10.3109/14767058.2016.1156670] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE To evaluate the association of short-term variation (STV) of the fetal heart rate in predicting fetal acidaemia at birth. METHODS The search strategy employed searching of electronic databases (MEDLINE, Web of Science, Scopus, and Google Scholar) and reference lists of relevant studies. Data were extracted from studies, adhering strictly to the following criteria: singleton pregnancy at ≥24 weeks' gestation, computerized CTG (index test) and calculation of STV before delivery. The outcome measure was arterial pH assessed in cord blood obtained at birth. RESULTS Meta-analysis showed moderate accuracy of STV in predicting fetal acidaemia with a sensitivity of 0.57 (95% CI: 0.45-0.68), specificity of 0.81 (95% CI: 0.69-0.89), positive likelihood ratio of 3.14 (95% CI: 2.13-4.63) and negative likelihood ratio of 0.58, (95% CI: 0.46-0.72). However, in intra-uterine growth restricted fetuses, a small improvement in detecting acidaemia was observed; with a sensitivity of 0.63 (95% CI: 0.49-0.75) and negative likelihood ratio of 0.50 (95% CI: 0.31-0.80). CONCLUSION STV appears to be a moderate predictor for fetal acidaemia. However, its usefulness as a stand-alone test in predicting acidaemia in clinical setting remains to be determined.
Collapse
Affiliation(s)
- Habiba Kapaya
- a Department of Human Metabolism , Academic Unit of Reproductive & Developmental Medicine , Sheffield , UK
| | - Richard Jacques
- b School of Health and Related Research (ScHARR), University of Sheffield , Sheffield , UK
| | - Nadia Rahaim
- a Department of Human Metabolism , Academic Unit of Reproductive & Developmental Medicine , Sheffield , UK
| | - Dilly Anumba
- a Department of Human Metabolism , Academic Unit of Reproductive & Developmental Medicine , Sheffield , UK
| |
Collapse
|
9
|
Abstract
BACKGROUND Cardiotocography (CTG) is a continuous recording of the fetal heart rate obtained via an ultrasound transducer placed on the mother's abdomen. CTG is widely used in pregnancy as a method of assessing fetal well-being, predominantly in pregnancies with increased risk of complications. OBJECTIVES To assess the effectiveness of antenatal CTG (both traditional and computerised assessments) in improving outcomes for mothers and babies during and after pregnancy. SEARCH METHODS We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (26 June 2015) and reference lists of retrieved studies. SELECTION CRITERIA Randomised and quasi-randomised trials that compared traditional antenatal CTG with no CTG or CTG results concealed; computerised CTG with no CTG or CTG results concealed; and computerised CTG with traditional CTG. DATA COLLECTION AND ANALYSIS Two review authors independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. MAIN RESULTS Six studies (involving 2105 women) are included. Overall, the included studies were not of high quality, and only two had both adequate randomisation sequence generation and allocation concealment. All studies that were able to be included enrolled only women at increased risk of complications.Comparison of traditional CTG versus no CTG showed no significant difference identified in perinatal mortality (risk ratio (RR) 2.05, 95% confidence interval (CI) 0.95 to 4.42, 2.3% versus 1.1%, four studies, N = 1627, low quality evidence) or potentially preventable deaths (RR 2.46, 95% CI 0.96 to 6.30, four studies, N = 1627), though the meta-analysis was underpowered to assess this outcome. Similarly, there was no significant difference identified in caesarean sections (RR 1.06, 95% CI 0.88 to 1.28, 19.7% versus 18.5%, three trials, N = 1279, low quality evidence). There was also no significant difference identified for secondary outcomes related to Apgar scores less than seven at five minutes (RR 0.83, 95% CI 0.37 to 1.88, one trial, N = 396, very low quality evidence); or admission to neonatal special care units or neonatal intensive care units (RR 1.08, 95% CI 0.84 to 1.39, two trials, N = 883, low quality evidence), nor in the other secondary outcomes that were assessed.There were no eligible studies that compared computerised CTG with no CTG.Comparison of computerised CTG versus traditional CTG showed a significant reduction in perinatal mortality with computerised CTG (RR 0.20, 95% CI 0.04 to 0.88, two studies, 0.9% versus 4.2%, 469 women, moderate quality evidence). However, there was no significant difference identified in potentially preventable deaths (RR 0.23, 95% CI 0.04 to 1.29, two studies, N = 469), though the meta-analysis was underpowered to assess this outcome. There was no significant difference identified in caesarean sections (RR 0.87, 95% CI 0.61 to 1.24, 63% versus 72%, one study, N = 59, low quality evidence), Apgar scores less than seven at five minutes (RR 1.31, 95% CI 0.30 to 5.74, two studies, N = 469, very low quality evidence) or in secondary outcomes. AUTHORS' CONCLUSIONS There is no clear evidence that antenatal CTG improves perinatal outcome, but further studies focusing on the use of computerised CTG in specific populations of women with increased risk of complications are warranted.
Collapse
Affiliation(s)
- Rosalie M Grivell
- Flinders University and Flinders Medical CentreDepartment of Obstetrics and GynaecologyBedford ParkSouth AustraliaAustraliaSA 5042
| | - Zarko Alfirevic
- The University of LiverpoolDepartment of Women's and Children's HealthFirst Floor, Liverpool Women's NHS Foundation TrustCrown StreetLiverpoolUKL8 7SS
| | - Gillian ML Gyte
- University of LiverpoolCochrane Pregnancy and Childbirth Group, Department of Women's and Children's HealthFirst Floor, Liverpool Women's NHS Foundation TrustCrown StreetLiverpoolUKL8 7SS
| | - Declan Devane
- National University of Ireland GalwaySchool of Nursing and MidwiferyUniversity RoadGalwayIreland
| | | |
Collapse
|
10
|
Computerized fetal heart rate analysis in the prediction of myocardial damage in pregnancies with placental insufficiency. Eur J Obstet Gynecol Reprod Biol 2015; 190:7-10. [DOI: 10.1016/j.ejogrb.2015.03.031] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2015] [Revised: 03/18/2015] [Accepted: 03/31/2015] [Indexed: 11/23/2022]
|
11
|
Abstract
AIM OF THE STUDY Analyzing velocimetric (umbilical artery, UA; ductus venosus, DV; middle cerebral artery, MCA) and computerized cardiotocographic (cCTG) (fetal heart rate, FHR; short term variability, STV; approximate entropy, ApEn) parameters in intrauterine growth restriction, IUGR, in order to detect early signs of fetal compromise. POPULATION STUDY: 375 pregnant women assisted from the 28th week of amenorrhea to delivery and monitored through cCTG and Doppler ultrasound investigation. The patients were divided into three groups according to the age of gestation at the time of delivery, before the 34th week, from 34th to 37th week, and after the 37th week. Data were analyzed in relation to the days before delivery and according to the physiology or pathology of velocimetry. Statistical analysis was performed through the t-test, chi-square test, and Pearson correlation test (P < 0.05). Our results evidenced an earlier alteration of UA, DV, and MCA. The analysis between cCTG and velocimetric parameters (the last distinguished into physiological and pathological values) suggests a possible relation between cCTG alterations and Doppler ones. The present study emphasizes the need for an antenatal testing in IUGR fetuses using multiple surveillance modalities to enhance prediction of neonatal outcome.
Collapse
|
12
|
Maeda MDFY, Nomura RMY, Niigaki JI, Francisco RPV, Zugaib M. Influence of fetal acidemia on fetal heart rate analyzed by computerized cardiotocography in pregnancies with placental insufficiency. J Matern Fetal Neonatal Med 2013; 26:1820-4. [DOI: 10.3109/14767058.2013.802304] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
13
|
Abstract
BACKGROUND Cardiotocography (CTG) is a continuous recording of the fetal heart rate obtained via an ultrasound transducer placed on the mother's abdomen. CTG is widely used in pregnancy as a method of assessing fetal well-being, predominantly in pregnancies with increased risk of complications. OBJECTIVES To assess the effectiveness of antenatal CTG (both traditional and computerised assessments) in improving outcomes for mothers and babies during and after pregnancy. SEARCH METHODS We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (9 July 2012) and reference lists of retrieved studies. SELECTION CRITERIA Randomised and quasi-randomised trials that compared traditional antenatal CTG with no CTG or CTG results concealed; computerised CTG with no CTG or CTG results concealed; and computerised CTG with traditional CTG. DATA COLLECTION AND ANALYSIS Two review authors independently assessed eligibility, quality and extracted data. MAIN RESULTS Six studies (involving 2105 women) are included. Overall, the included studies were not of high quality, and only two had both adequate randomisation sequence generation and allocation concealment. All studies that were able to be included enrolled only women at increased risk of complications.Comparison of traditional CTG versus no CTG showed no significant difference identified in perinatal mortality (risk ratio (RR) 2.05, 95% confidence interval (CI) 0.95 to 4.42, 2.3% versus 1.1%, four studies, N = 1627) or potentially preventable deaths (RR 2.46, 95% CI 0.96 to 6.30, four studies, N = 1627), though the meta-analysis was underpowered to assess this outcome. Similarly, there was no significant difference identified in caesarean sections (RR 1.06, 95% CI 0.88 to 1.28, 19.7% versus 18.5%, three trials, N = 1279) nor in the secondary outcomes that were assessed.There were no eligible studies that compared computerised CTG with no CTG.Comparison of computerised CTG versus traditional CTG showed a significant reduction in perinatal mortality with computerised CTG (RR 0.20, 95% CI 0.04 to 0.88, two studies, 0.9% versus 4.2%, 469 women). However, there was no significant difference identified in potentially preventable deaths (RR 0.23, 95% CI 0.04 to 1.29, two studies, N = 469), though the meta-analysis was underpowered to assess this outcome. There was no significant difference identified in caesarean sections (RR 0.87, 95% CI 0.61 to 1.24, 63% versus 72%, one study, N = 59) or in secondary outcomes. AUTHORS' CONCLUSIONS There is no clear evidence that antenatal CTG improves perinatal outcome, but further studies focusing on the use of computerised CTG in specific populations of women with increased risk of complications are warranted.
Collapse
Affiliation(s)
- Rosalie M Grivell
- Discipline of Obstetrics and Gynaecology, The University of Adelaide, Women’s and Children’s Hospital, Adelaide, Australia.
| | | | | | | |
Collapse
|
14
|
Abstract
BACKGROUND Cardiotocography (CTG) is a continuous recording of the fetal heart rate obtained via an ultrasound transducer placed on the mother's abdomen. CTG is widely used in pregnancy as a method of assessing fetal well-being, predominantly in pregnancies with increased risk of complications. OBJECTIVES To assess the effectiveness of antenatal CTG (both traditional and computerised assessments) in improving outcomes for mothers and babies during and after pregnancy. SEARCH STRATEGY We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (April 2009). SELECTION CRITERIA Randomised and quasi-randomised trials that compared traditional antenatal CTG with no CTG or CTG results concealed; computerised CTG with no CTG or CTG results concealed; and computerised CTG with traditional CTG. DATA COLLECTION AND ANALYSIS Two authors independently assessed eligibility, quality and extracted data. MAIN RESULTS Six studies (involving 2105 women) are included. Overall, the included studies were not of high quality, and only two had both adequate randomisation sequence generation and allocation concealment. All studies that were able to be included enrolled only women at increased risk of complications.Comparison of traditional CTG versus no CTG showed no significant difference identified in perinatal mortality (risk ratio (RR) 2.05, 95% confidence interval (CI) 0.95 to 4.42, 2.3% versus 1.1%, four studies, N = 1627) or potentially preventable deaths (RR 2.46, 95% CI 0.96 to 6.30, four studies, N = 1627, though the meta-analysis was underpowered to assess this outcome. Similarly, there was no significant difference identified in caesarean sections (RR 1.06, 95% CI 0.88 to 1.28, 19.7% versus 18.5%, three trials, N = 1279) nor in the secondary outcomes that were assessed.There were no eligible studies that compared computerised CTG with no CTG.Comparison of computerised CTG versus traditional CTG showed a significant reduction in perinatal mortality with computerised CTG (RR 0.20, 95% CI 0.04 to 0.88, two studies, 0.9% versus 4.2%, 469 women, graph 3.1.1). However, there was no significant difference identified in potentially preventable deaths (RR 0.23, 95% CI 0.04 to 1.29, two studies, N = 469), though the meta-analysis was underpowered to assess this outcome. There was no significant difference identified in caesarean sections (RR 0.87, 95% CI 0.61 to 1.24, 63% versus 72%, one study, N = 59) or in secondary outcomes. AUTHORS' CONCLUSIONS There is no clear evidence that antenatal CTG improves perinatal outcome, but further studies focusing on the use of computerised CTG in specific populations of women with increased risk of complications are warranted.
Collapse
Affiliation(s)
- Rosalie M Grivell
- Discipline of Obstetrics and Gynaecology, The University of Adelaide, Women's and Children's Hospital, 72 King William Road, Adelaide, Australia, SA 5006
| | | | | | | |
Collapse
|
15
|
Grivell RM, Alfirevic Z, Gyte GML, Devane D. Antenatal cardiotocography for fetal assessment. THE COCHRANE DATABASE OF SYSTEMATIC REVIEWS 2009. [DOI: 10.1002/14651858.cd007863] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
16
|
Bibliography. Current world literature. Maternal-fetal medicine. Curr Opin Obstet Gynecol 2007; 19:196-201. [PMID: 17353689 DOI: 10.1097/gco.0b013e32812142e7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|