1
|
Taurisano M, Mancini A, D'elia F. CEUS-guided PTA on stenotic AVF: Morphological and functional point of view. J Vasc Access 2024; 25:576-583. [PMID: 36217665 DOI: 10.1177/11297298221126289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Stenosis represents the main cause of hemodialysis fistula malfunction. The ultrasound-guided angioplasty with ecographic contrast (CEUS) could provide further advantages to the classical ultrasound guided method improving the morphological characterization of the stenosis and providing quantitative data with the creation of time intensity curves (TIC) collecting functional data comparable between pre and post procedure. METHODS A total of 10 CEUS-guided angioplasties were performed on malfunctioning fistulas. The sonographic contrast medium was injected into the vascular tree trough the introducer. Morphological and functional data nature were collected. Were generated TIC curves, obtained by positioning a ROI in correspondence with the post-stenotic tract of the efferent vein. The data collected, regarding the peak intensity reached by the signal (PI) and the time to reach the peak signal intensity (TTP), were compared in the pre and post-procedural phase with flow of vascular access (Qa) and resistance indices (RI). RESULTS Statistically significant correlation (p < 0.05) was observed between Qa and TTP (r = 0.77; p = 0.009), RI and TTP (r = 0.71; p = 0.02), Qa and PI (r = 0.86; p = 0.0012), and between RI and PI (r = 0.88; p < 0.001). CONCLUSION In addition to the advantages associated with the use of ultrasound contrast medium in improving the visualization and characterization of the stenosis by facilitating the PTA procedure, the functional data deriving from the quantitative analysis provide new parameters for evaluating the success of the procedure which could also be used as predictive markers of stenosis recurrence together with the classical ones.
Collapse
Affiliation(s)
- Marco Taurisano
- Department of Nephrology, Hospital Di Venere and John XXIII, Bari, Italy
| | - Andrea Mancini
- Department of Nephrology, Hospital Di Venere and John XXIII, Bari, Italy
| | - Filomena D'elia
- Department of Nephrology, Hospital Di Venere and John XXIII, Bari, Italy
| |
Collapse
|
2
|
Chou T, Nabavinia M, Tram NK, Rimmerman ET, Patel S, Musini KN, Eisert SN, Wolfe T, Wynveen MK, Matsuzaki Y, Kitsuka T, Iwaki R, Janse SA, Bobbey AJ, Breuer CK, Goodchild L, Malbrue R, Shinoka T, Atway SA, Go MR, Stacy MR. Quantification of Skeletal Muscle Perfusion in Peripheral Artery Disease Using 18F-Sodium Fluoride Positron Emission Tomography Imaging. J Am Heart Assoc 2024; 13:e031823. [PMID: 38353265 PMCID: PMC11010069 DOI: 10.1161/jaha.123.031823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 11/07/2023] [Indexed: 02/16/2024]
Abstract
BACKGROUND Perfusion deficits contribute to symptom severity, morbidity, and death in peripheral artery disease (PAD); however, no standard method for quantifying absolute measures of skeletal muscle perfusion exists. This study sought to preclinically test and clinically translate a positron emission tomography (PET) imaging approach using an atherosclerosis-targeted radionuclide, fluorine-18-sodium fluoride (18F-NaF), to quantify absolute perfusion in PAD. METHODS AND RESULTS Eight Yorkshire pigs underwent unilateral femoral artery ligation and dynamic 18F-NaF PET/computed tomography imaging on the day of and 2 weeks after occlusion. Following 2-week imaging, calf muscles were harvested to quantify microvascular density. PET methodology was validated with microspheres in 4 additional pig studies and translated to patients with PAD (n=39) to quantify differences in calf perfusion across clinical symptoms/stages and perfusion responses in a case of revascularization. Associations between PET perfusion, ankle-brachial index, toe-brachial index, and toe pressure were assessed in relation to symptoms. 18F-NaF PET/computed tomography quantified significant deficits in calf perfusion in pigs following arterial occlusion and perfusion recovery 2 weeks after occlusion that coincided with increased muscle microvascular density. Additional studies confirmed that PET-derived perfusion measures agreed with microsphere-derived perfusion measures. Translation of imaging methods demonstrated significant decreases in calf perfusion with increasing severity of PAD and quantified perfusion responses to revascularization. Perfusion measures were also significantly associated with symptom severity, whereas traditional hemodynamic measures were not. CONCLUSIONS 18F-NaF PET imaging quantifies perfusion deficits that correspond to clinical stages of PAD and represents a novel perfusion imaging strategy that could be partnered with atherosclerosis-targeted 18F-NaF PET imaging using a single radioisotope injection. REGISTRATION URL: https://www.clinicaltrials.gov; Unique identifier: NCT03622359.
Collapse
Affiliation(s)
- Ting‐Heng Chou
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Mahboubeh Nabavinia
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Nguyen K. Tram
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Eleanor T. Rimmerman
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
- Biophysics Graduate ProgramOhio State UniversityColumbusOH
| | - Surina Patel
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Kumudha Narayana Musini
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Susan Natalie Eisert
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Tatiana Wolfe
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Molly K. Wynveen
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Yuichi Matsuzaki
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Takahiro Kitsuka
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Ryuma Iwaki
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
| | | | - Adam J. Bobbey
- Department of RadiologyNationwide Children’s HospitalColumbusOH
| | - Christopher K. Breuer
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Laurie Goodchild
- Animal Resources CoreResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Raphael Malbrue
- Animal Resources CoreResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Toshiharu Shinoka
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
| | - Said A. Atway
- Department of OrthopaedicsOhio State University College of MedicineColumbusOH
| | - Michael R. Go
- Division of Vascular Diseases & Surgery, Department of SurgeryOhio State University College of MedicineColumbusOH
| | - Mitchel R. Stacy
- Center for Regenerative MedicineResearch Institute at Nationwide Children’s HospitalColumbusOH
- Biophysics Graduate ProgramOhio State UniversityColumbusOH
- Division of Vascular Diseases & Surgery, Department of SurgeryOhio State University College of MedicineColumbusOH
| |
Collapse
|
3
|
Prior SJ, Chrencik MT, Christensen E, Kundi R, Ryan AS, Addison O, Lal BK. An exercise stress test for contrast-enhanced duplex ultrasound assessment of lower limb muscle perfusion in patients with peripheral arterial disease. J Vasc Surg 2024; 79:397-404. [PMID: 37844848 PMCID: PMC10969459 DOI: 10.1016/j.jvs.2023.10.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 10/10/2023] [Accepted: 10/10/2023] [Indexed: 10/18/2023]
Abstract
OBJECTIVE The aim of the present study was to develop a standardized contrast-enhanced duplex ultrasound (CE-DUS) protocol to assess lower-extremity muscle perfusion before and after exercise and determine relationships of perfusion with clinical and functional measures. METHODS CE-DUS (EPIQ 5G, Philips) was used before and immediately after a 10-minute, standardized bout of treadmill walking to compare microvascular perfusion of the gastrocnemius muscle in older (55-82 years) patients with peripheral arterial disease (PAD) (n = 15, mean ankle-brachial index, 0.78 ± 0.04) and controls (n = 13). Microvascular blood volume (MBV) and microvascular flow velocity (MFV) were measured at rest and immediately following treadmill exercise, and the Modified Physical Performance Test (MPPT) was used to assess mobility function. RESULTS In the resting state (pre-exercise), MBV in patients with PAD was not significantly different than normal controls (5.17 ± 0.71 vs 6.20 ± 0.83 arbitrary units (AU) respectively; P = .36); however, after exercise, MBV was ∼40% lower in patients with PAD compared with normal controls (5.85 ± 1.13 vs 9.53 ± 1.31 AU, respectively; P = .04). Conversely, MFV was ∼60% higher in patients with PAD compared with normal controls after exercise (0.180 ± 0.016 vs 0.113 ± 0.018 AU, respectively; P = .01). There was a significant between-group difference in the exercise-induced changes in both MBV and MFV (P ≤ .05). Both basal and exercise MBV directly correlated with MPPT score in the patients with PAD (r = 0.56-0.62; P < .05). CONCLUSIONS This standardized protocol for exercise stress testing of the lower extremities quantifies calf muscle perfusion and elicits perfusion deficits in patients with PAD. This technique objectively quantifies microvascular perfusion deficits that are related to reduced mobility function and could be used to assess therapeutic efficacy in patients with PAD.
Collapse
Affiliation(s)
- Steven J Prior
- Department of Kinesiology, University of Maryland School of Public Health, College Park, MD; Department of Veterans Affairs and Baltimore Veterans Affairs Medical Center Geriatric Research, Education and Clinical Center (GRECC), Baltimore, MD; Department of Medicine, Division of Gerontology, Geriatrics and Palliative Medicine, University of Maryland School of Medicine, Baltimore, MD
| | - Matthew T Chrencik
- Department of Surgery, Division of Vascular Surgery, University of Maryland School of Medicine and Baltimore Veterans Affairs Medical Center, Baltimore, MD
| | - Eric Christensen
- Department of Veterans Affairs and Baltimore Veterans Affairs Medical Center Geriatric Research, Education and Clinical Center (GRECC), Baltimore, MD; Department of Medicine, Division of Gerontology, Geriatrics and Palliative Medicine, University of Maryland School of Medicine, Baltimore, MD
| | - Rishi Kundi
- Department of Surgery, Division of Vascular Surgery, University of Maryland School of Medicine and Baltimore Veterans Affairs Medical Center, Baltimore, MD
| | - Alice S Ryan
- Department of Veterans Affairs and Baltimore Veterans Affairs Medical Center Geriatric Research, Education and Clinical Center (GRECC), Baltimore, MD; Department of Medicine, Division of Gerontology, Geriatrics and Palliative Medicine, University of Maryland School of Medicine, Baltimore, MD
| | - Odessa Addison
- Department of Veterans Affairs and Baltimore Veterans Affairs Medical Center Geriatric Research, Education and Clinical Center (GRECC), Baltimore, MD; Department of Physical Therapy and Rehabilitation Science, University of Maryland School of Medicine, Baltimore
| | - Brajesh K Lal
- Department of Surgery, Division of Vascular Surgery, University of Maryland School of Medicine and Baltimore Veterans Affairs Medical Center, Baltimore, MD.
| |
Collapse
|
4
|
Menêses A, Krastins D, Nam M, Bailey T, Quah J, Sankhla V, Lam J, Jha P, Schulze K, O'Donnell J, Magee R, Golledge J, Greaves K, Askew CD. Toward a Better Understanding of Muscle Microvascular Perfusion During Exercise in Patients With Peripheral Artery Disease: The Effect of Lower-Limb Revascularization. J Endovasc Ther 2024; 31:115-125. [PMID: 35898156 DOI: 10.1177/15266028221114722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE Leg muscle microvascular blood flow (perfusion) is impaired in response to maximal exercise in patients with peripheral artery disease (PAD); however, during submaximal exercise, microvascular perfusion is maintained due to a greater increase in microvascular blood volume compared with that seen in healthy adults. It is unclear whether this submaximal exercise response reflects a microvascular impairment, or whether it is a compensatory response for the limited conduit artery flow in PAD. Therefore, to clarify the role of conduit artery blood flow, we compared whole-limb blood flow and skeletal muscle microvascular perfusion responses with exercise in patients with PAD (n=9; 60±7 years) prior to, and following, lower-limb endovascular revascularization. MATERIALS AND METHODS Microvascular perfusion (microvascular volume × flow velocity) of the medial gastrocnemius muscle was measured before and immediately after a 5 minute bout of submaximal intermittent isometric plantar-flexion exercise using contrast-enhanced ultrasound imaging. Exercise contraction-by-contraction whole-leg blood flow and vascular conductance were measured using strain-gauge plethysmography. RESULTS With revascularization there was a significant increase in whole-leg blood flow and conductance during exercise (p<0.05). Exercise-induced muscle microvascular perfusion response did not change with revascularization (pre-revascularization: 3.19±2.32; post-revascularization: 3.89±1.67 aU.s-1; p=0.38). However, the parameters that determine microvascular perfusion changed, with a reduction in the microvascular volume response to exercise (pre-revascularization: 6.76±3.56; post-revascularization: 2.42±0.69 aU; p<0.01) and an increase in microvascular flow velocity (pre-revascularization: 0.25±0.13; post-revascularization: 0.59±0.25 s-1; p=0.02). CONCLUSION These findings suggest that patients with PAD compensate for the conduit artery blood flow impairment with an increase in microvascular blood volume to maintain muscle perfusion during submaximal exercise. CLINICAL IMPACT The findings from this study support the notion that the impairment in conduit artery blood flow in patients with PAD leads to compensatory changes in microvascular blood volume and flow velocity to maintain muscle microvascular perfusion during submaximal leg exercise. Moreover, this study demonstrates that these microvascular changes are reversed and become normalized with successful lower-limb endovascular revascularization.
Collapse
Affiliation(s)
- Annelise Menêses
- VasoActive Research Group, School of Health, University of the Sunshine Coast, Sippy Downs, QLD, Australia
| | - Digby Krastins
- VasoActive Research Group, School of Health, University of the Sunshine Coast, Sippy Downs, QLD, Australia
| | - Michael Nam
- Department of Cardiology, Sunshine Coast University Hospital, Birtinya, QLD, Australia
| | - Tom Bailey
- VasoActive Research Group, School of Health, University of the Sunshine Coast, Sippy Downs, QLD, Australia
- Physiology and Ultrasound Laboratory in Science and Exercise, Centre for Research on Exercise, Physical Activity & Health, School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Jing Quah
- Department of Cardiology, Sunshine Coast University Hospital, Birtinya, QLD, Australia
| | - Vaibhav Sankhla
- Department of Cardiology, Sunshine Coast University Hospital, Birtinya, QLD, Australia
| | - Jeng Lam
- Department of Cardiology, Sunshine Coast University Hospital, Birtinya, QLD, Australia
| | - Pankaj Jha
- Department of Vascular Surgery, Sunshine Coast University Hospital, Birtinya, QLD, Australia
| | - Karl Schulze
- Sunshine Vascular Clinic, Buderim, QLD, Australia
| | - Jill O'Donnell
- Department of Vascular Surgery, Sunshine Coast University Hospital, Birtinya, QLD, Australia
| | - Rebecca Magee
- Department of Vascular Surgery, Sunshine Coast University Hospital, Birtinya, QLD, Australia
| | - Jonathan Golledge
- Queensland Research Centre for Peripheral Vascular Disease, College of Medicine and Dentistry, James Cook University and Department of Vascular and Endovascular Surgery, Townsville University Hospital, Townsville, QLD, Australia
| | - Kim Greaves
- Department of Cardiology, Sunshine Coast University Hospital, Birtinya, QLD, Australia
- Sunshine Coast Health Institute, Sunshine Coast Hospital and Health Service, Birtinya, QLD, Australia
| | - Christopher D Askew
- VasoActive Research Group, School of Health, University of the Sunshine Coast, Sippy Downs, QLD, Australia
- Sunshine Coast Health Institute, Sunshine Coast Hospital and Health Service, Birtinya, QLD, Australia
| |
Collapse
|
5
|
Chen SY, Wang YW, Chen WS, Hsiao MY. Update of Contrast-enhanced Ultrasound in Musculoskeletal Medicine: Clinical Perspectives - A Review. J Med Ultrasound 2023; 31:92-100. [PMID: 37576422 PMCID: PMC10413398 DOI: 10.4103/jmu.jmu_94_22] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 10/03/2022] [Accepted: 10/07/2022] [Indexed: 08/15/2023] Open
Abstract
Contrast-enhanced ultrasound (CEUS) uses an intravascular contrast agent to enhance blood flow signals and assess microcirculation in different parts of the human body. Over the past decade, CEUS has become more widely applied in musculoskeletal (MSK) medicine, and the current review aims to systematically summarize current research on the application of CEUS in the MSK field, focusing on 67 articles published between January 2001 and June 2021 in online databases including PubMed, Scopus, and Embase. CEUS has been widely used for the clinical assessment of muscle microcirculation, tendinopathy, fracture nonunions, sports-related injuries, arthritis, peripheral nerves, and tumors, and can serve as an objective and quantitative evaluation tool for prognosis and outcome prediction. Optimal CEUS parameters and diagnostic cut off values for each disease category remain to be confirmed.
Collapse
Affiliation(s)
- Shao-Yu Chen
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan
| | - Yao-Wei Wang
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan
| | - Wen-Shiang Chen
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan
- Department of Physical Medicine and Rehabilitation, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Ming-Yen Hsiao
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan
- Department of Physical Medicine and Rehabilitation, College of Medicine, National Taiwan University, Taipei, Taiwan
| |
Collapse
|
6
|
Galanakis N, Maris TG, Kontopodis N, Tsetis K, Kehagias E, Tsetis D. Perfusion imaging techniques in lower extremity peripheral arterial disease. Br J Radiol 2022; 95:20211203. [PMID: 35522774 PMCID: PMC10996332 DOI: 10.1259/bjr.20211203] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Revised: 04/17/2022] [Accepted: 04/21/2022] [Indexed: 11/05/2022] Open
Abstract
Lower limb peripheral arterial disease (PAD) characterizes the impairment of blood flow to extremities caused by arterial stenoses or occlusions. Evaluation of PAD is based on clinical examination, calculation of ankle-brachial index and imaging studies such as ultrasound, CT, MRI and digital subtraction angiography. These modalities provide significant information about location, extension and severity of macrovasular lesions in lower extremity arterial system. However, they can be also used to evaluate limb perfusion, using appropriate techniques and protocols. This information may be valuable for assessment of the severity of ischemia and detection of hypoperfused areas. Moreover, they can be used for planning of revascularization strategy in patients with severe PAD and evaluation of therapeutic outcome. These techniques may also determine prognosis and amputation risk in patients with PAD. This review gives a basic overview of the perfusion techniques for lower limbs provided by imaging modalities such as ultrasound, CT, MRI, digital subtraction angiography and scintigraphy and their clinical applications for evaluation of PAD and revascularization outcome.
Collapse
Affiliation(s)
- Nikolaos Galanakis
- Department of Medical Imaging, University Hospital Heraklion,
University of Crete Medical School,
Heraklion, Greece
| | - Thomas G Maris
- Department of Medical Physics, University Hospital Heraklion,
University of Crete Medical School,
Heraklion, Greece
| | - Nikolaos Kontopodis
- Vascular Surgery Unit, Department of Cardiothoracic and
Vascular Surgery, University Hospital Heraklion, University of Crete
Medical School, Heraklion,
Greece
| | - Konstantinos Tsetis
- Department of Medical Imaging, University Hospital Heraklion,
University of Crete Medical School,
Heraklion, Greece
| | - Elias Kehagias
- Department of Medical Imaging, University Hospital Heraklion,
University of Crete Medical School,
Heraklion, Greece
| | - Dimitrios Tsetis
- Department of Medical Imaging, University Hospital Heraklion,
University of Crete Medical School,
Heraklion, Greece
| |
Collapse
|
7
|
Wang Y, Zhao P, Li N, Dong Z, Lin L, Liu J, Liang S, Wang Q, Tang J, Luo Y. A Study on Correlation between Contrast-Enhanced Ultrasound Parameters and Pathological Features of Diabetic Nephropathy. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:228-236. [PMID: 34789402 DOI: 10.1016/j.ultrasmedbio.2021.08.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 07/12/2021] [Accepted: 08/17/2021] [Indexed: 06/13/2023]
Abstract
The objective of this study was to evaluate the correlation between contrast-enhanced ultrasound (CEUS) parameters and histopathological features in patients with diabetic nephropathy (DN). Sixty-two patients with DN (44 men, mean age: 52.61 ± 10.63 y) were enrolled. They underwent renal biopsy for DN at the Department of Ultrasound, PLA Hospital, between May 2017 and February 2020. Renal tissue was obtained by ultrasound-guided percutaneous needle biopsy. CEUS was performed, and time-intensity curves (TICs) and renal perfusion parameters were analyzed. Differences in CEUS parameters were analyzed according to the glomerular classification and interstitial fibrosis-tubular atrophy (IFTA) score. Continuous variables were evaluated using the analysis of variance or Mann-Whitney U-test. Discontinuous variables were compared with the χ2-test. Spearman correlation analyses evaluated associations among quantitative ultrasound perfusion parameters and histopathological characteristics. Peak enhancement (PE), wash-in rate (WiR), wash-in perfusion index (WiPI) and wash-out rate (WoR) of the cortex, and their cortex/medulla ratios, decreased with increasing glomerular classification grade (p < 0.05). The fall time (FT) of the cortex, and their cortex/medulla ratios, increased with increasing glomerular classification grade (p < 0.05). There were no significant differences in the CEUS parameters for different IFTA scores. The perfusion volume-relevant parameters (such as PE, WiR and WiPI) had a negative correlation (p < 0.05), while the perfusion time-relevant parameters (such as RT and FT) had a positive correlation (p < 0.05), with the severity of glomerular lesions, glomerulosclerosis rate and number of Kimmelstiel-Wilson lesions. The CEUS parameters of the cortex could reflect pathological characteristics, especially changes in glomerular lesions.
Collapse
Affiliation(s)
- Yiru Wang
- Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing, China; Medical School of Chinese PLA, Beijing, China
| | - Ping Zhao
- Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing, China; Medical School of Chinese PLA, Beijing, China
| | - Nan Li
- Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Zheyi Dong
- Department of Nephrology, First Medical Center, Chinese PLA General Hospital, Chinese PLA Institute of Nephrology, Beijing Key Laboratory of Kidney Diseases, Beijing, China; State Key Laboratory of Kidney Diseases, National Clinical Research Center of Kidney Diseases, Beijing, China
| | - Lin Lin
- Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Jiaona Liu
- Department of Nephrology, First Medical Center, Chinese PLA General Hospital, Chinese PLA Institute of Nephrology, Beijing Key Laboratory of Kidney Diseases, Beijing, China; State Key Laboratory of Kidney Diseases, National Clinical Research Center of Kidney Diseases, Beijing, China
| | - Shiyuan Liang
- Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Qian Wang
- Department of Nephrology, First Medical Center, Chinese PLA General Hospital, Chinese PLA Institute of Nephrology, Beijing Key Laboratory of Kidney Diseases, Beijing, China; State Key Laboratory of Kidney Diseases, National Clinical Research Center of Kidney Diseases, Beijing, China
| | - Jie Tang
- Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing, China; Medical School of Chinese PLA, Beijing, China
| | - Yukun Luo
- Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing, China; Medical School of Chinese PLA, Beijing, China; State Key Laboratory of Kidney Diseases, National Clinical Research Center of Kidney Diseases, Beijing, China.
| |
Collapse
|
8
|
Ntoulia A, Barnewolt CE, Doria AS, Ho-Fung VM, Lorenz N, Mentzel HJ, Back SJ. Contrast-enhanced ultrasound for musculoskeletal indications in children. Pediatr Radiol 2021; 51:2303-2323. [PMID: 33783575 DOI: 10.1007/s00247-021-04964-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 09/02/2020] [Accepted: 01/07/2021] [Indexed: 12/14/2022]
Abstract
The increasing use of contrast-enhanced ultrasound (CEUS) has opened exciting new frontiers for musculoskeletal applications in adults and children. The most common musculoskeletal-related CEUS applications in adults are for detecting inflammatory joint diseases, imaging skeletal muscles and tendon perfusion, imaging postoperative viability of osseous and osseocutaneous tissue flaps, and evaluating the malignant potential of soft-tissue masses. Pediatric musculoskeletal-related CEUS has been applied for imaging juvenile idiopathic arthritis and Legg-Calvé-Perthes disease and for evaluating femoral head perfusion following surgical hip reduction in children with developmental hip dysplasia. CEUS can improve visualization of the capillary network in superficial and deep tissues and also in states of slow- or low-volume blood flow. In addition, measurements of blood flow imaging parameters performed by quantitative CEUS are valuable when monitoring the outcome of treatment interventions. In this review article we present current experience regarding a wide range of CEUS applications in musculoskeletal conditions in adults and children, with emphasis on the latter, and discuss imaging techniques and CEUS findings in musculoskeletal applications.
Collapse
Affiliation(s)
- Aikaterini Ntoulia
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA.
| | - Carol E Barnewolt
- Department of Radiology, Boston Children's Hospital, Harvard University, Boston, MA, USA
| | - Andrea S Doria
- Department of Medical Imaging, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Victor M Ho-Fung
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA.,Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA, USA
| | - Norbert Lorenz
- Children's Hospital, Dresden Municipal Hospital, Teaching-Hospital of Technical University, Dresden, Germany
| | - Hans-Joachim Mentzel
- Section of Pediatric Radiology, Institute of Diagnostic and Interventional Radiology, University Hospital of Jena, Jena, Germany
| | - Susan J Back
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA.,Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
9
|
Troy AM, Cheng HM. Human microvascular reactivity: a review of vasomodulating stimuli and non-invasive imaging assessment. Physiol Meas 2021; 42. [PMID: 34325417 DOI: 10.1088/1361-6579/ac18fd] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 07/29/2021] [Indexed: 11/11/2022]
Abstract
The microvasculature serves an imperative function in regulating perfusion and nutrient exchange throughout the body, adaptively altering blood flow to preserve hemodynamic and metabolic homeostasis. Its normal functioning is vital to tissue health, whereas its dysfunction is present in many chronic conditions, including diabetes, heart disease, and cognitive decline. As microvascular dysfunction often appears early in disease progression, its detection can offer early diagnostic information. To detect microvascular dysfunction, one uses imaging to probe the microvasculature's ability to react to a stimulus, also known as microvascular reactivity (MVR). An assessment of MVR requires an integrated understanding of vascular physiology, techniques for stimulating reactivity, and available imaging methods to capture the dynamic response. Practical considerations, including compatibility between the selected stimulus and imaging approach, likewise require attention. In this review, we provide a comprehensive foundation necessary for informed imaging of MVR, with a particular focus on the challenging endeavor of assessing microvascular function in deep tissues.
Collapse
Affiliation(s)
- Aaron M Troy
- Institute of Biomedical Engineering, University of Toronto, Toronto, CANADA
| | | |
Collapse
|
10
|
Chou TH, Alvelo JL, Janse S, Papademetris X, Sumpio BE, Mena-Hurtado C, Sinusas AJ, Stacy MR. Prognostic Value of Radiotracer-Based Perfusion Imaging in Critical Limb Ischemia Patients Undergoing Lower Extremity Revascularization. JACC Cardiovasc Imaging 2020; 14:1614-1624. [PMID: 33221224 DOI: 10.1016/j.jcmg.2020.09.033] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 09/03/2020] [Accepted: 09/10/2020] [Indexed: 02/07/2023]
Abstract
OBJECTIVES The purpose of this study was to evaluate the prognostic value of single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging of angiosome foot perfusion for predicting amputation outcomes in patients with critical limb ischemia (CLI) and diabetes mellitus (DM). BACKGROUND Radiotracer imaging can assess microvascular foot perfusion and identify regional perfusion abnormalities in patients with critical limb ischemia CLI and DM, but the relationship between perfusion response to revascularization and subsequent clinical outcomes has not been evaluated. METHODS Patients with CLI, DM, and nonhealing foot ulcers (n = 25) were prospectively enrolled for SPECT/CT perfusion imaging of the feet before and after revascularization. CT images were used to segment angiosomes (i.e., 3-dimensional vascular territories) of the foot. Relative changes in radiotracer uptake after revascularization were evaluated within the ulcerated angiosome. Incidence of amputation was assessed at 3 and 12 months after revascularization. RESULTS SPECT/CT detected a significantly lower microvascular perfusion response for patients who underwent amputation compared with those who remained amputation free at 3 (p = 0.01) and 12 (p = 0.01) months after revascularization. The cutoff percent change in perfusion for predicting amputation at 3 months was 7.55%, and 11.56% at 12 months. The area under the curve based on the amputation outcome was 0.799 at 3 months and 0.833 at 12 months. The probability of amputation-free survival was significantly higher at 3 (p = 0.002) and 12 months (p = 0.03) for high-perfusion responders than low-perfusion responders to revascularization. CONCLUSIONS SPECT/CT imaging detects regional perfusion responses to lower extremity revascularization and provides prognostic value in patients with CLI (Radiotracer-Based Perfusion Imaging of Patients With Peripheral Arterial Disease; NCT03622359).
Collapse
Affiliation(s)
- Ting-Heng Chou
- Center for Regenerative Medicine, The Research Institute at Nationwide Children's Hospital, Columbus, Ohio, USA; Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Jessica L Alvelo
- Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Sarah Janse
- Center for Biostatistics, The Ohio State University, Columbus, Ohio, USA
| | - Xenophon Papademetris
- Department of Radiology & Biomedical Imaging, Yale University School of Medicine, New Haven, Connecticut, USA; Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
| | - Bauer E Sumpio
- Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut, USA; Department of Radiology & Biomedical Imaging, Yale University School of Medicine, New Haven, Connecticut, USA; Department of Surgery, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Carlos Mena-Hurtado
- Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Albert J Sinusas
- Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut, USA; Department of Radiology & Biomedical Imaging, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Mitchel R Stacy
- Center for Regenerative Medicine, The Research Institute at Nationwide Children's Hospital, Columbus, Ohio, USA; Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut, USA; Department of Surgery, The Ohio State University College of Medicine, Columbus, Ohio, USA.
| |
Collapse
|
11
|
Young GM, Krastins D, Chang D, Lam J, Quah J, Stanton T, Russell F, Greaves K, Kriel Y, Askew CD. Influence of cuff‐occlusion duration on contrast‐enhanced ultrasound assessments of calf muscle microvascular blood flow responsiveness in older adults. Exp Physiol 2020; 105:2238-2245. [DOI: 10.1113/ep089065] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Accepted: 10/02/2020] [Indexed: 11/08/2022]
Affiliation(s)
- Grace Marie Young
- VasoActive Research Group School of Health and Sport Sciences University of the Sunshine Coast Sippy Downs Queensland Australia
- Sunshine Coast Hospital and Health Service Sunshine Coast Health Institute Birtinya Queensland Australia
| | - Digby Krastins
- VasoActive Research Group School of Health and Sport Sciences University of the Sunshine Coast Sippy Downs Queensland Australia
- Sunshine Coast Hospital and Health Service Sunshine Coast Health Institute Birtinya Queensland Australia
| | - David Chang
- Department of Cardiac Services Sunshine Coast Hospital and Health Service Birtinya Queensland Australia
| | - Jeng Lam
- Department of Cardiac Services Sunshine Coast Hospital and Health Service Birtinya Queensland Australia
| | - Jing Quah
- Department of Cardiac Services Sunshine Coast Hospital and Health Service Birtinya Queensland Australia
| | - Tony Stanton
- VasoActive Research Group School of Health and Sport Sciences University of the Sunshine Coast Sippy Downs Queensland Australia
- Department of Cardiac Services Sunshine Coast Hospital and Health Service Birtinya Queensland Australia
| | - Fraser Russell
- VasoActive Research Group School of Health and Sport Sciences University of the Sunshine Coast Sippy Downs Queensland Australia
| | - Kim Greaves
- VasoActive Research Group School of Health and Sport Sciences University of the Sunshine Coast Sippy Downs Queensland Australia
- Department of Cardiac Services Sunshine Coast Hospital and Health Service Birtinya Queensland Australia
| | - Yuri Kriel
- VasoActive Research Group School of Health and Sport Sciences University of the Sunshine Coast Sippy Downs Queensland Australia
| | - Christopher David Askew
- VasoActive Research Group School of Health and Sport Sciences University of the Sunshine Coast Sippy Downs Queensland Australia
- Sunshine Coast Hospital and Health Service Sunshine Coast Health Institute Birtinya Queensland Australia
- Department of Cardiac Services Sunshine Coast Hospital and Health Service Birtinya Queensland Australia
| |
Collapse
|
12
|
Preoperative deltoid assessment by contrast-enhanced ultrasound (CEUS) as predictor for shoulder function after reverse shoulder arthroplasty: a prospective pilot study. Arch Orthop Trauma Surg 2020; 140:1001-1012. [PMID: 31624864 DOI: 10.1007/s00402-019-03281-w] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2019] [Indexed: 10/25/2022]
Abstract
INTRODUCTION Although the deltoid represents the main motor muscle after reverse shoulder arthroplasty (RSA), its standardized preoperative assessment regarding morphology and function is still not established. Its clinical relevance and interactions with major biomechanical parameters like the medialization of the center of rotation (COR) regarding shoulder function after RSA are yet unknown. We evaluated contrast-enhanced ultrasound (CEUS) of the deltoid as possible surrogate marker for individual deltoid properties of patients receiving an RSA, and its predictive value for postoperative shoulder function. MATERIALS AND METHODS 35 patients were prospectively assessed. Before and 6 months after RSA, dynamic deltoid perfusion, caliber and a combination of both (PE*caliber, named DeltoidEfficacy) was quantified by CEUS. Changes of deltoid properties and the predictive value of preoperative CEUS-based deltoid properties for shoulder function after RSA were assessed. To analyze interrelating effects with deltoid properties, COR-medialization and deltoid lengthening were quantified. RESULTS Deltoid caliber and perfusion significantly increased after RSA (p = 0.0004/p = 0.002). Preoperative deltoid caliber, perfusion and the combined value DeltoidEfficacy significantly correlated with shoulder function after RSA within the whole study cohort (caliber: r = 0.445, p = 0.009; perfusion: r = 0.593, p = 0.001; DeltoidEfficacy: r = 0.66; p = 0.0002). The predictive value of DeltoidEfficacy for shoulder function after RSA varied among patient subgroups: Multivariate regression analysis revealed the strongest prediction in patients with either very high or very low deltoid properties (Beta = 0.872, r = 0.84, p = 0.0004), independent from COR-medialization or deltoid lengthening. Contrary, in patients with intermediate deltoid properties, COR-medialization revealed the strongest predictive value for shoulder function after RSA (Beta = 0.660, r = 0.597; p = 0.024). CONCLUSION Deltoid CEUS seems to allow an assessment of individual deltoid properties and deltoid adaptations after RSA. Deltoid CEUS seems to predict shoulder function after RSA and might support an identification of patients requiring special attention regarding COR positioning.
Collapse
|
13
|
Fischer C, Krix M, Weber MA, Loizides A, Gruber H, Jung EM, Klauser A, Radzina M, Dietrich CF. Contrast-Enhanced Ultrasound for Musculoskeletal Applications: A World Federation for Ultrasound in Medicine and Biology Position Paper. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1279-1295. [PMID: 32139152 DOI: 10.1016/j.ultrasmedbio.2020.01.028] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 01/23/2020] [Accepted: 01/24/2020] [Indexed: 06/10/2023]
Abstract
This World Federation for Ultrasound in Medicine and Biology position paper reviews the diagnostic potential of ultrasound contrast agents for clinical decision-making and provides general advice for optimal contrast-enhanced ultrasound performance in musculoskeletal issues. In this domain, contrast-enhanced ultrasound performance has increasingly been investigated with promising results, but still lacks everyday clinical application and standardized techniques; therefore, experts summarized current knowledge according to published evidence and best personal experience. The goal was to intensify and standardize the use and administration of ultrasound contrast agents to facilitate correct diagnoses and ultimately to improve the management and outcomes of patients.
Collapse
Affiliation(s)
- Christian Fischer
- Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, Ultrasound Center, HTRG-Heidelberg Trauma Research Group, Heidelberg University Hospital, Heidelberg, Germany.
| | | | - Marc-André Weber
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Rostock, Germany
| | - Alexander Loizides
- Department of Radiology, Ultrasound Center, Innsbruck Medical University, Innsbruck, Austria
| | - Hannes Gruber
- Department of Radiology, Ultrasound Center, Innsbruck Medical University, Innsbruck, Austria
| | | | - Andrea Klauser
- Department of Radiology, Ultrasound Center, Innsbruck Medical University, Innsbruck, Austria
| | - Maija Radzina
- Diagnostic Radiology Institute, Riga Stradins University, Riga, Latvia
| | | |
Collapse
|
14
|
Kunz P, Kiesl S, Groß S, Kauczor HU, Schmidmaier G, Fischer C. Intra-observer and Device-Dependent Inter-observer Reliability of Contrast-Enhanced Ultrasound for Muscle Perfusion Quantification. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:275-285. [PMID: 31733932 DOI: 10.1016/j.ultrasmedbio.2019.10.007] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2019] [Revised: 10/06/2019] [Accepted: 10/11/2019] [Indexed: 06/10/2023]
Abstract
Muscle perfusion quantification by contrast-enhanced ultrasound (CEUS) may facilitate treatment decisions in musculoskeletal disorders. Translation into clinical routine relies on high intra-observer and inter-observer reliability and transferability between ultrasound devices to enable validation and multicenter studies. This study evaluates these aspects for deltoid muscle perfusion quantification, including possible multicenter study setups. One hundred sixty-six CEUS quantifications were conducted on 42 shoulders. Intra-observer reliability revealed a high intra-class correlation coefficient (ICC, r = 0.91) and low coefficient of variation (CV, 10.28%). Inter-observer reliability revealed an ICC of .84 and a CV of 17.1%, but these values decreased when different ultrasound devices were used (ICC = .60, CV = 18.6%). Re-evaluating subgroups with high sectional plane concordance significantly increased reliability (intra-observer: ICC = .97, CV = 5.49%, inter-observer/same device: ICC = .98, CV = 5.83%, varying devices: ICC = .78, CV = 9.8%). CEUS perfusion quantification of the deltoid seems applicable for multicenter studies, yet pooling different ultrasound devices remains critical. Sectional plane concordance appears to be crucial for reliability and transferability of CEUS muscle perfusion quantifications.
Collapse
Affiliation(s)
- Pierre Kunz
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Ultrasound Centre, HTRG, Heidelberg University Hospital, Heidelberg, Germany; Clinic for Shoulder and Elbow Surgery, Catholic Hospital Mainz, Mainz, Germany.
| | - Sophia Kiesl
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Ultrasound Centre, HTRG, Heidelberg University Hospital, Heidelberg, Germany
| | - Sascha Groß
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Ultrasound Centre, HTRG, Heidelberg University Hospital, Heidelberg, Germany
| | - Hans-Ulrich Kauczor
- Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Gerhard Schmidmaier
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Ultrasound Centre, HTRG, Heidelberg University Hospital, Heidelberg, Germany
| | - Christian Fischer
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Ultrasound Centre, HTRG, Heidelberg University Hospital, Heidelberg, Germany
| |
Collapse
|
15
|
Thakrar DB, Sultan MJ. The Role of Contrast-Enhanced Ultrasound in Managing Vascular Pathologies. J Med Imaging Radiat Sci 2019; 50:590-595. [PMID: 31706878 DOI: 10.1016/j.jmir.2019.08.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2019] [Revised: 07/24/2019] [Accepted: 08/08/2019] [Indexed: 11/15/2022]
Abstract
INTRODUCTION Ultrasound is a useful first-line imaging modality for diagnosing and monitoring vascular pathologies. Compared with other modalities, it is relatively low cost, requires no ionizing radiation, is often available at bedside, and is noninvasive. However, the modality can have limitations when differentiating normal from pathologic tissues. In this review, we discuss the role of contrast-enhanced ultrasound (CEUS) in carotid, aortic, and peripheral vascular conditions. DISCUSSION CEUS is a developing modality that supersedes standard vascular ultrasound imaging and complements other modalities such as computed topography and magnetic resonance angiograms. Administered intravenously, the contrast are microbubbles filled with gas, surrounded by a stabilizing shell. They have the ability to enhance the quality of images and quantify vascular pathologies by acting as intravascular tracers of ultrasound energy. Based on these properties, CEUS has the potential to play a pivotal role in the management of vascular pathologies through its utility in detection, diagnosis, risk-stratification, follow-up, and monitoring. CONCLUSION Studies have suggested that CEUS is superior compared with standard ultrasound and on-par with computed topography angiograms in the detection of vascular pathologies, concluding that CEUS should be part of standardized routine practice.
Collapse
Affiliation(s)
- Dixa B Thakrar
- Department of Vascular Surgery, Hull University Teaching Hospitals NHS Trust, Hull, UK
| | | |
Collapse
|
16
|
Sah BR, Veit-Haibach P, Strobel K, Banyai M, Huellner MW. CT-perfusion in peripheral arterial disease - Correlation with angiographic and hemodynamic parameters. PLoS One 2019; 14:e0223066. [PMID: 31560706 PMCID: PMC6764684 DOI: 10.1371/journal.pone.0223066] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2019] [Accepted: 09/12/2019] [Indexed: 12/14/2022] Open
Abstract
Objective The purpose of this study was the assessment of volumetric CT-perfusion (CTP) of the lower leg musculature in patients with symptomatic peripheral arterial disease (PAD) of the lower extremities, comparing it with established angiographic and hemodynamic parameters. Materials and methods Thirty-five consecutive patients with symptomatic PAD of the lower extremities requiring interventional revascularization were assessed prospectively. All patients underwent a CTP scan of the lower leg, and hemodynamic and angiographic assessment. Hemodynamic parameters, specifically ankle-brachial pressure index (ABI), ankle blood pressure (ABP), peak systolic velocity (PSV), and segmental pulse oscillography (SPO) level, were determined. Lesion length and degree of collateralization were assessed by interventional angiography. CTP parameters were calculated with a perfusion software, acting on a no outflow assumption. A sequential two-compartment model was used. Differences in CTP parameters and correlations between CTP, hemodynamic and angiographic parameters were assessed with non-parametric tests. Results The cohort consisted of 27 subjects with an occlusion, and eight with a high-grade stenosis. The mean blood flow (BF) was 7.71 ± 2.96 ml/100ml*min-1, mean blood volume (BV) 0.71 ± 0.33 ml/100ml, and mean mean transit time (MTT) 7.22 ± 2.66 s. BF and BV were higher in subjects with longer lesions, and BV was higher in subjects with lower ABI. Significant correlations were found between lesion length and BV (r = 0.65) and BF (r = 0.52). Significant inverse correlations were found between BV and ABI and between BV and ABP (r = -0.56, for both correlations). Conclusions In our study, we have shown the feasibility of CTP for the assessment of PAD. In the future, this quantitative method might serve as a non-invasive method, possibly complementing the diagnostic workup of patients with peripheral arterial disease.
Collapse
Affiliation(s)
- Bert-Ram Sah
- Department of Diagnostic, Interventional, and Pediatric Radiology, Inselspital, University of Bern, Bern, Switzerland
- Department of Cancer Imaging, King’s College London, London, England, United Kingdom
- * E-mail:
| | - Patrick Veit-Haibach
- Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland
- Department of Radiology, University Hospital Zurich, Zurich, Switzerland
- University of Zurich, Zurich, Switzerland
- Joint Department of Medical Imaging, University of Toronto, Toronto, Canada
- Department of Radiology and Nuclear Medicine, Lucerne Cantonal Hospital, Lucerne, Switzerland
| | - Klaus Strobel
- Department of Radiology and Nuclear Medicine, Lucerne Cantonal Hospital, Lucerne, Switzerland
| | - Martin Banyai
- Department of Internal Medicine, Subdivision of Angiology, Lucerne Cantonal Hospital, Lucerne, Switzerland
- Clinic for Angiology, University Hospital Zurich, Zurich, Switzerland
| | - Martin W. Huellner
- Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland
- University of Zurich, Zurich, Switzerland
- Department of Radiology and Nuclear Medicine, Lucerne Cantonal Hospital, Lucerne, Switzerland
| |
Collapse
|
17
|
Abstract
METHODICAL ISSUE Contrast-enhanced ultrasound (CEUS) offers easily accessible visualization and quantification of the skeletal muscle microcirculation and other tissues in vivo and in real-time with almost no side effects. AIM The aim of this review is to present the increasing number of musculoskeletal CEUS applications. METHODICAL INNOVATIONS/PERFORMANCE CEUS applications regarding the musculoskeletal system include applications at bone and joints extending beyond the visualization of only the muscular microcirculation. Besides basic muscle physiology, impaired microcirculation in patients with peripheral artery disease or diabetes mellitus and the diagnosis of inflammatory myopathies have been the subject of previous CEUS studies. More recent studies in orthopedics and traumatology have focused on osseous and muscular perfusion characteristics, e. g., in differentiating infected and aseptic non-unions or the impact of different types of implants and prostheses on muscular microcirculation as a surrogate marker of clinical success. PRACTICAL RECOMMENDATIONS CEUS of the musculoskeletal system is used in clinical trials or off-label. Therefore, it is not well established in clinical routine. However, considering the increasing number of musculoskeletal CEUS applications, this could change in the future.
Collapse
|
18
|
Nguyen T, Davidson BP. Contrast Enhanced Ultrasound Perfusion Imaging in Skeletal Muscle. J Cardiovasc Imaging 2019; 27:163-177. [PMID: 31161755 PMCID: PMC6669180 DOI: 10.4250/jcvi.2019.27.e31] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Accepted: 04/21/2019] [Indexed: 12/14/2022] Open
Abstract
The ability to accurately evaluate skeletal muscle microvascular blood flow has broad clinical applications for understanding the regulation of skeletal muscle perfusion in health and disease states. Contrast-enhanced ultrasound (CEU) perfusion imaging, a technique originally developed to evaluate myocardial perfusion, is one of many techniques that have been applied to evaluate skeletal muscle perfusion. Among the advantages of CEU perfusion imaging of skeletal muscle is that it is rapid, safe and performed with equipment already present in most vascular medicine laboratories. The aim of this review is to discuss the use of CEU perfusion imaging in skeletal muscle. This article provides details of the protocols for CEU imaging in skeletal muscle, including two predominant methods for bolus and continuous infusion destruction-replenishment techniques. The importance of stress perfusion imaging will be highlighted, including a discussion of the methods used to produce hyperemic skeletal muscle blood flow. A broad overview of the disease states that have been studied in humans using CEU perfusion imaging of skeletal muscle will be presented including: (1) peripheral arterial disease; (2) sickle cell disease; (3) diabetes; and (4) heart failure. Finally, future applications of CEU imaging in skeletal muscle including therapeutic CEU imaging will be discussed along with technological developments needed to advance the field.
Collapse
Affiliation(s)
- TheAnh Nguyen
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| | - Brian P Davidson
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA.,Veterans Affairs Portland Health Care System, Portland, OR, USA.
| |
Collapse
|
19
|
Hou XX, Chu GH, Yu Y. Prospects of Contrast-Enhanced Ultrasonography for the Diagnosis of Peripheral Arterial Disease: A Meta-analysis. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2018; 37:1081-1090. [PMID: 29064120 DOI: 10.1002/jum.14451] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Revised: 07/03/2017] [Accepted: 07/24/2017] [Indexed: 06/07/2023]
Abstract
OBJECTIVES Contrast-enhanced ultrasonography (CEUS) is a modern diagnostic method that can also be used to study microperfusion. This study compared the time to peak intensity measured by CEUS in patients with peripheral arterial disease (PAD) and healthy control participants. METHODS After a comprehensive literature search in multiple electronic databases and study selection, a random-effect meta-analysis was performed to compare the time to peak intensity measured by CEUS in patients with PAD and healthy controls, which followed meta-regression analyses for identification of factors affecting the outcomes. RESULTS Fourteen studies (data for 322 patients with PAD and 314 healthy individuals) were used for the meta-analysis. The age of this sample of patients with PAD was 64.92 (95% confidence interval, 62.53, 67.31) years, and that of the healthy controls was 55.32 (51.67, 58.98) years. The times to peak intensity were 18.55 (15.62, 21.48) seconds in healthy controls, 33.40 (27.65, 39.15) seconds in patients with PAD, and 76.22 (36.23, 116.22) seconds in patients with PAD and diabetes mellitus. The difference between patients with PAD and healthy controls in the time to peak intensity was statistically significant (mean difference, 24.80 [10.16, 39.44] seconds; P < .00009). The ABI was not significantly associated with the time to peak intensity in patients with PAD. Age and sex were also not significantly associated with the time to peak intensity. CONCLUSIONS Contrast-enhanced ultrasonography is a valuable tool for the diagnosis of PAD based on its ability to differentiate the time to peak intensity between patients with PAD and healthy individuals, but little data are yet available to assess its diagnostic ability in clinical practice.
Collapse
Affiliation(s)
- Xiao-Xia Hou
- Department of Medical Ultrasound Center, Northwest Women and Children's Hospital, Xi'an, China
| | - Guang-Hua Chu
- Department of Gynecology, Northwest Women and Children's Hospital, Xi'an, China
| | - Yuan Yu
- Department of Hand and Foot Micro-Surgery, Ankang Central Hospital of Shaanxi Province, Ankang, China
| |
Collapse
|
20
|
Cheung WK, Williams KJ, Christensen-Jeffries K, Dharmarajah B, Eckersley RJ, Davies AH, Tang MX. A Temporal and Spatial Analysis Approach to Automated Segmentation of Microbubble Signals in Contrast-Enhanced Ultrasound Images: Application to Quantification of Active Vascular Density in Human Lower Limbs. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:2221-2234. [PMID: 28693905 DOI: 10.1016/j.ultrasmedbio.2017.05.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2016] [Revised: 05/17/2017] [Accepted: 05/21/2017] [Indexed: 06/07/2023]
Abstract
Contrast-enhanced ultrasound (CEUS) using microbubble contrast agents has shown great promise in visualising and quantifying active vascular density. Most existing approaches for vascular density quantification using CEUS are calculated based on image intensity and are susceptible to confounding factors and imaging artefact. Poor reproducibility is a key challenge to clinical translation. In this study, a new automated temporal and spatial signal analysis approach is developed for reproducible microbubble segmentation and quantification of contrast enhancement in human lower limbs. The approach is evaluated in vitro on phantoms and in vivo in lower limbs of healthy volunteers before and after physical exercise. In this approach, vascular density is quantified based on the relative areas microbubbles occupy instead of their image intensity. Temporal features of the CEUS image sequences are used to identify pixels that contain microbubble signals. A microbubble track density (MTD) measure, the ratio of the segmented microbubble area to the whole tissue area, is calculated as a surrogate for active capillary density. In vitro results reveal a good correlation (r2 = 0.89) between the calculated MTD measure and the known bubble concentration. For in vivo results, a significant increase (129% in average) in the MTD measure is found in lower limbs of healthy volunteers after exercise, with excellent repeatability over a series of days (intra-class correlation coefficient = 0.96). This compares to the existing state-of-the-art approach of destruction and replenishment analysis on the same patients (intra-class correlation coefficient ≤0.78). The proposed new approach shows great potential as an accurate and highly reproducible clinical tool for quantification of active vascular density.
Collapse
Affiliation(s)
| | | | | | | | - Robert J Eckersley
- Division of Imaging Sciences & Biomedical Engineering, King's College London, London, UK
| | - Alun H Davies
- Section of Surgery, Imperial College, Charing Cross Hospital, London, UK
| | - Meng-Xing Tang
- Department of Bioengineering, Imperial College, London, UK.
| |
Collapse
|
21
|
Vascular applications of contrast-enhanced ultrasound imaging. J Vasc Surg 2017; 66:266-274. [DOI: 10.1016/j.jvs.2016.12.133] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2016] [Accepted: 12/16/2016] [Indexed: 01/29/2023]
|
22
|
Davidson BP, Belcik JT, Landry G, Linden J, Lindner JR. Exercise versus vasodilator stress limb perfusion imaging for the assessment of peripheral artery disease. Echocardiography 2017; 34:1187-1194. [PMID: 28664576 DOI: 10.1111/echo.13601] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
PURPOSE Our aim was to determine whether pharmacologic vasodilation is an alternative to exercise stress during limb perfusion imaging for peripheral artery disease (PAD). METHODS Quantitative contrast-enhanced ultrasound (CEU) perfusion imaging of the bilateral anterior thigh and calf was performed in nine control subjects and nine patients with moderate to severe PAD at rest and during vasodilator stress with dipyridamole. For those who were able, CEU of the calf was then performed during modest plantar flexion exercise (20 watts). CEU time-intensity data were analyzed to quantify microvascular blood flow (MBF) and its parametric components of microvascular blood volume and flux rate. RESULTS Thigh and calf skeletal muscle MBF at rest was similar between control and PAD patients. During dipyridamole, MBF increased minimally (<twofold) for all groups and there were only nonsignificant trends for a reduction in calf MBF in those with PAD (13.5±6.9, 10.0±4.7, and 8.2±6.1 IU/s, for controls, moderate, and severe PAD, respectively; P=.11). In contrast, MBF during modest planar flexion exercise increased markedly in controls but not PAD patients (87.9±79.9 vs 15.2±12.9 IU/s, P<.05). In three moderate PAD patients restudied after undergoing surgical revascularization, MBF during dipyridamole did not change, whereas exercise MBF increased by an average of sevenfold. CONCLUSIONS Resting limb skeletal muscle MBF in patients with moderate to severe PAD is similar to that in normal subjects. However, differences in hyperemic flow during contractile exercise but not during dipyridamole allow evaluation of the degree of flow impairment from PAD and the degree of improvement with revascularization.
Collapse
Affiliation(s)
- Brian P Davidson
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA.,VA Portland Health Care System, Portland, OR, USA
| | - J Todd Belcik
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| | - Gregory Landry
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| | - Joel Linden
- La Jolla Institute for Allergy and Immunology, UCSD, San Diego, CA, USA
| | - Jonathan R Lindner
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| |
Collapse
|
23
|
Kundi R, Prior SJ, Addison O, Lu M, Ryan AS, Lal BK. Contrast-Enhanced Ultrasound Reveals Exercise-Induced Perfusion Deficits in Claudicants. ACTA ACUST UNITED AC 2017; 2. [PMID: 28691118 PMCID: PMC5501290 DOI: 10.21767/2573-4482.100041] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Background Contrast-Enhanced Ultrasonography (CEUS) is an imaging modality allowing
perfusion quantification in targeted regions of interest of the lower extremity that has
not been possible with color-flow imaging or with measurement of ankle brachial indices.
We developed a protocol to quantify lower extremity muscle perfusion impairment in PAD
patients in response to exercise. Methods and findings Thirteen patients with Rutherford Class I-III Peripheral Arterial Disease (PAD)
and no prior revascularization procedures were recruited from the Baltimore Veterans
Affairs Medical Center and compared with eight control patients without PAD. CEUS
interrogation of the index limb gastrocnemius muscle was performed using an intravenous
bolus of lipid-stabilized microsphere contrast before and after a standardized treadmill
protocol. Peak perfusion (PEAK) and time to peak perfusion (TTP) were measured before
and after exercise. Between and within group differences were assessed. Control subjects
demonstrated a more rapid TTP (p<0.01) and an increase in peak perfusion (PEAK,
p=0.02) after exercise, when compared to their baseline measures. Patients with
PAD demonstrated TTP and PEAK measures equivalent to controls at baseline
(p=0.39, p=0.71, respectively). However, they exhibited no significant
exercise-induced changes in perfusion (TTP p=0.49 and PEAK 0.67, respectively
compared to baseline). After exercise, normal subjects had significantly shorter TTP
(p=0.04) and greater PEAK (p=0.02) than PAD patients. Conclusion Consistent with their lack of ischemic symptoms at rest, class I to III
claudicant PAD patients showed similar perfusion measures (TTP and PEAK) at rest. PAD
patients, however, were unable to increase perfusion in response to exercise, whereas
controls increased perfusion significantly. This corresponds with claudication and
limited walking capacity observed in PAD. CEUS with bolus injection offers a convenient,
objective, quantitative and visual physiologic assessment of perfusion limitation in
specific muscle groups of PAD patients. This has the potential for substantial clinical
and research utility.
Collapse
Affiliation(s)
- Rishi Kundi
- Department of Surgery, Division of Vascular Surgery, Baltimore VA Medical Center, University of Maryland School of Medicine, Baltimore, USA
| | - Steven J Prior
- Department of Veterans Affairs and Baltimore Veterans Affairs Medical Center Geriatric Research, Education and Clinical Center (GRECC), USA.,Department of Medicine, Division of Gerontology and Geriatric Medicine, University of Maryland School of Medicine, Baltimore, USA
| | - Odessa Addison
- Department of Veterans Affairs and Baltimore Veterans Affairs Medical Center Geriatric Research, Education and Clinical Center (GRECC), USA.,Department of Medicine, Division of Gerontology and Geriatric Medicine, University of Maryland School of Medicine, Baltimore, USA
| | - Michael Lu
- Department of Veterans Affairs and Baltimore Veterans Affairs Medical Center Geriatric Research, Education and Clinical Center (GRECC), USA.,Department of Medicine, Division of Gerontology and Geriatric Medicine, University of Maryland School of Medicine, Baltimore, USA
| | - Alice S Ryan
- Department of Veterans Affairs and Baltimore Veterans Affairs Medical Center Geriatric Research, Education and Clinical Center (GRECC), USA.,Department of Medicine, Division of Gerontology and Geriatric Medicine, University of Maryland School of Medicine, Baltimore, USA
| | - Brajesh K Lal
- Department of Surgery, Division of Vascular Surgery, Baltimore VA Medical Center, University of Maryland School of Medicine, Baltimore, USA
| |
Collapse
|
24
|
Combined Lower Limb Revascularisation and Supervised Exercise Training for Patients with Peripheral Arterial Disease: A Systematic Review of Randomised Controlled Trials. Sports Med 2016; 47:987-1002. [DOI: 10.1007/s40279-016-0635-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
25
|
Fischer C, Frank M, Kunz P, Tanner M, Weber MA, Moghaddam A, Schmidmaier G, Hug A. Dynamic contrast-enhanced ultrasound (CEUS) after open and minimally invasive locked plating of proximal humerus fractures. Injury 2016; 47:1725-31. [PMID: 27242329 DOI: 10.1016/j.injury.2016.05.005] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2016] [Revised: 04/26/2016] [Accepted: 05/06/2016] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Closed reduction and locked plate fixation of proximal humerus fractures with the minimally invasive deltoid-splitting approach intends to minimize soft tissue damage although axillary nerve injury has been reported. The aim of this study was to assess the deltoid muscle perfusion with dynamic contrast-enhanced ultrasound (CEUS) as novel technique and evaluate its relation to the functional and neurologic outcome after open (ORIF) and minimally invasive (MIPO) fracture fixation. PATIENTS AND METHODS 50 patients, 30 with deltopectoral ORIF and 20 with deltoid-splitting MIPO approach were examined 6-49 months after surgery. Only patients with a healthy, contralateral shoulder were selected. Shoulder function, satisfaction as well as psychosocial outcome were assessed with established scores (Constant, DASH, Simple Shoulder Test, ASES, SF-12). Electromyography (EMG) of the deltoid muscle was performed to determine axillary nerve damage. Ultrasound of both shoulders included CEUS and Power Doppler after deltoid muscle activation via active abduction for two minutes. RESULTS None of the examinations and scores showed significant differences between ORIF and MIPO patients, the psychosocial outcome was similar. The fracture types were equally distributed in both groups. The normalized Constant Score was 76.3±18.6 in the ORIF and 81.6±16.1 in the MIPO group (p=0.373). Deltoid muscle perfusion in CEUS and Power Doppler revealed no differences between both approaches. EMG excluded functionally relevant axillary nerve injuries. Compared with the contralateral shoulder, Constant- and ASES-Scores (p≤0.001 for both ORIF and MIPO) as well as the deltoid CEUS perfusion (ORIF p=0.035; MIPO p=0.030) were significantly worse for both approaches. CONCLUSIONS Convincing consensus of functional, ultrasonographic and neurologic examinations demonstrated comparable outcomes after deltopectoral and deltoid-splitting approach. The quantification of the deltoid muscle perfusion with CEUS indicates that the proclaimed benefits of the MIPO approach on soft tissue might not be as great as expected.
Collapse
Affiliation(s)
- Christian Fischer
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany.
| | - Marion Frank
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Pierre Kunz
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Michael Tanner
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Marc-André Weber
- Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Arash Moghaddam
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Gerhard Schmidmaier
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Andreas Hug
- Spinal Cord Injury Center, Heidelberg University Hospital, Heidelberg, Germany
| |
Collapse
|
26
|
Yang C, Lee DH, Mangraviti A, Su L, Zhang K, Zhang Y, Zhang B, Li W, Tyler B, Wong J, Wang KKH, Velarde E, Zhou J, Ding K. Quantitative correlational study of microbubble-enhanced ultrasound imaging and magnetic resonance imaging of glioma and early response to radiotherapy in a rat model. Med Phys 2016; 42:4762-72. [PMID: 26233204 DOI: 10.1118/1.4926550] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
PURPOSE Radiotherapy remains a major treatment method for malignant tumors. Magnetic resonance imaging (MRI) is the standard modality for assessing glioma treatment response in the clinic. Compared to MRI, ultrasound imaging is low-cost and portable and can be used during intraoperative procedures. The purpose of this study was to quantitatively compare contrast-enhanced ultrasound (CEUS) imaging and MRI of irradiated gliomas in rats and to determine which quantitative ultrasound imaging parameters can be used for the assessment of early response to radiation in glioma. METHODS Thirteen nude rats with U87 glioma were used. A small thinned skull window preparation was performed to facilitate ultrasound imaging and mimic intraoperative procedures. Both CEUS and MRI with structural, functional, and molecular imaging parameters were performed at preradiation and at 1 day and 4 days postradiation. Statistical analysis was performed to determine the correlations between MRI and CEUS parameters and the changes between pre- and postradiation imaging. RESULTS Area under the curve (AUC) in CEUS showed significant difference between preradiation and 4 days postradiation, along with four MRI parameters, T2, apparent diffusion coefficient, cerebral blood flow, and amide proton transfer-weighted (APTw) (all p < 0.05). The APTw signal was correlated with three CEUS parameters, rise time (r = - 0.527, p < 0.05), time to peak (r = - 0.501, p < 0.05), and perfusion index (r = 458, p < 0.05). Cerebral blood flow was correlated with rise time (r = - 0.589, p < 0.01) and time to peak (r = - 0.543, p < 0.05). CONCLUSIONS MRI can be used for the assessment of radiotherapy treatment response and CEUS with AUC as a new technique and can also be one of the assessment methods for early response to radiation in glioma.
Collapse
Affiliation(s)
- Chen Yang
- Department of Ultrasound, Zhejiang Cancer Hospital, Hangzhou, Zhejiang 310022, China
| | - Dong-Hoon Lee
- Division of MR Research, Department of Radiology, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21287
| | - Antonella Mangraviti
- Department of Neurosurgery, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21287
| | - Lin Su
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| | - Kai Zhang
- Division of MR Research, Department of Radiology, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21287
| | - Yin Zhang
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| | - Bin Zhang
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| | - Wenxiao Li
- Division of MR Research, Department of Radiology, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21287
| | - Betty Tyler
- Department of Neurosurgery, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21287
| | - John Wong
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| | - Ken Kang-Hsin Wang
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| | - Esteban Velarde
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| | - Jinyuan Zhou
- Division of MR Research, Department of Radiology, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21287
| | - Kai Ding
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| |
Collapse
|
27
|
Masumoto N, Kadoya T, Amioka A, Kajitani K, Shigematsu H, Emi A, Matsuura K, Arihiro K, Okada M. Evaluation of Malignancy Grade of Breast Cancer Using Perflubutane-Enhanced Ultrasonography. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:1049-1057. [PMID: 26895755 DOI: 10.1016/j.ultrasmedbio.2015.12.023] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2014] [Revised: 12/13/2015] [Accepted: 12/21/2015] [Indexed: 06/05/2023]
Abstract
Whether the contrast effects of perflubutane on contrast-enhanced ultrasonography can predict the malignancy grade of breast cancer is unknown. We analyzed associations between perfusion parameters created from time-intensity curves based on enhancement intensity and temporal changes in contrast-enhanced ultrasonography and clinicopathologic factors in 100 consecutive patients with invasive breast cancer. Values of perfusion parameters were significantly greater in estrogen receptor-negative than -positive tumors (peak intensity, p = 0.0002; ascending slope, p = 0.006; area under the curve, p = 0.0006). Variations in the peak intensity of Ki-67 were significantly correlated in all tumors (r = 0.54, p < 0.0001) and in luminal (r = 0.43, p = 0.0002), human epidermal growth factor receptor type 2-positive (r = 0.47, p = 0.047) and triple-negative (r = 0.55, p = 0.043) tumors. Perfusion parameters on contrast-enhanced ultrasonography can provide excellent predictive value for high-grade malignancy and might help to determine appropriate therapeutic strategies.
Collapse
Affiliation(s)
- Norio Masumoto
- Department of Surgical Oncology, Research Institute for Radiation Biology and Medicine, Hiroshima University, Hiroshima, Japan
| | - Takayuki Kadoya
- Department of Surgical Oncology, Research Institute for Radiation Biology and Medicine, Hiroshima University, Hiroshima, Japan
| | - Ai Amioka
- Department of Surgical Oncology, Research Institute for Radiation Biology and Medicine, Hiroshima University, Hiroshima, Japan
| | - Keiko Kajitani
- Department of Surgical Oncology, Research Institute for Radiation Biology and Medicine, Hiroshima University, Hiroshima, Japan
| | - Hideo Shigematsu
- Department of Surgical Oncology, Research Institute for Radiation Biology and Medicine, Hiroshima University, Hiroshima, Japan
| | - Akiko Emi
- Department of Surgical Oncology, Research Institute for Radiation Biology and Medicine, Hiroshima University, Hiroshima, Japan
| | - Kazuo Matsuura
- Department of Surgical Oncology, Research Institute for Radiation Biology and Medicine, Hiroshima University, Hiroshima, Japan
| | - Koji Arihiro
- Department of Anatomical Pathology, Hiroshima University Hospital, Hiroshima, Japan
| | - Morihito Okada
- Department of Surgical Oncology, Research Institute for Radiation Biology and Medicine, Hiroshima University, Hiroshima, Japan.
| |
Collapse
|
28
|
Partovi S, Kaspar M, Aschwanden M, Robbin MR, Bilecen D, Walker UA, Staub D. Quantitative dynamic contrast-enhanced ultrasound for the functional evaluation of the skeletal muscle microcirculation in systemic sclerosis. Clin Hemorheol Microcirc 2016; 62:35-44. [DOI: 10.3233/ch-151929] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Sasan Partovi
- Department of Radiology, University Hospitals Case Medical Center, Case Western Reserve University, Cleveland, OH, USA
| | - Mathias Kaspar
- Department of Internal Medicine, Division of Angiology, University Hospital, Basel, Switzerland
| | - Markus Aschwanden
- Department of Internal Medicine, Division of Angiology, University Hospital, Basel, Switzerland
| | - Mark R. Robbin
- Department of Radiology, University Hospitals Case Medical Center, Case Western Reserve University, Cleveland, OH, USA
| | - Deniz Bilecen
- Department of Radiology, Kantonsspital Laufen, Laufen, Switzerland
| | - Ulrich A. Walker
- Department of Rheumatology, University Hospital Basel, Basel, Switzerland
| | - Daniel Staub
- Department of Internal Medicine, Division of Angiology, University Hospital, Basel, Switzerland
| |
Collapse
|
29
|
Yuan HX, Cao JY, Kong WT, Xia HS, Wang X, Wang WP. Contrast-enhanced ultrasound in diagnosis of gallbladder adenoma. Hepatobiliary Pancreat Dis Int 2015; 14:201-7. [PMID: 25865694 DOI: 10.1016/s1499-3872(15)60351-4] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND Gallbladder adenoma is a pre-cancerous neoplasm and needs surgical resection. It is difficult to differentiate adenoma from other gallbladder polyps using imaging examinations. The study aimed to illustrate characteristics of contrast-enhanced ultrasound (CEUS) and its diagnostic value in gallbladder adenoma. METHODS Thirty-seven patients with 39 gallbladder adenomatoid lesions (maximal diameter ≥10 mm and without metastasis) were enrolled in this study. Lesion appearances in conventional ultrasound and CEUS were documented. The imaging features were compared individually among gallbladder cholesterol polyp, gallbladder adenoma and malignant lesion. RESULTS Adenoma lesions showed iso-echogenicity in ultrasound, and an eccentric enhancement pattern, "fast-in and synchronous-out" contrast enhancement pattern and homogeneous at peak-time enhancement in CEUS. The homogenicity at peak-time enhancement showed the highest diagnostic ability in differentiating gallbladder adenoma from cholesterol polyps. The sensitivity, specificity, positive predictive value, negative predictive value, accuracy and Youden index were 100%, 90.9%, 92.9%, 100%, 95.8% and 0.91, respectively. The characteristic of continuous gallbladder wall shown by CEUS had the highest diagnostic ability in differentiating adenoma from malignant lesion (100%, 86.7%, 86.7%, 100%, 92.9% and 0.87, respectively). The characteristic of the eccentric enhancement pattern had the highest diagnostic ability in differentiating adenoma from cholesterol polyp and malignant lesion, with corresponding indices of 69.2%, 88.5%, 75.0%, 85.2%, 82.1% and 0.58, respectively. CONCLUSIONS CEUS is valuable in differentiating gallbladder adenoma from other gallbladder polyps (≥10 mm in diameter). Homogeneous echogenicity on peak-time enhancement, a continuous gallbladder wall, and the eccentric enhancement pattern are important indicators of gallbladder adenoma on CEUS.
Collapse
Affiliation(s)
- Hai-Xia Yuan
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
| | | | | | | | | | | |
Collapse
|
30
|
Oh J, Jeon S, Choi J. Contrast-enhanced ultrasonography to assess blood perfusion of skeletal muscles in normal dogs. J Vet Med Sci 2015; 77:783-8. [PMID: 25754794 PMCID: PMC4527499 DOI: 10.1292/jvms.14-0328] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
This study evaluated perfusion of skeletal muscle using contrast enhanced ultrasonography in humerus, radius, femur and tibia in normal dogs. Contrast enhanced ultrasonography for each region was performed after injecting 0.5 mL and 1 mL of contrast medium (SonoVue) in every dog. Blood perfusion was assessed quantitatively by measuring the peak intensity, time to the peak intensity and area under the curve from the time-intensity curve. Vascularization in skeletal muscle was qualitatively graded with a score of 0-3 according to the number of vascular signals. A parabolic shape of time-intensity curve was observed from muscles in normal dogs, and time to the peak intensity, the peak intensity and area under the curve of each muscle were not significantly different according to the appendicular regions examined and the dosage of contrast agent administered. This study reports that feasibility of contrast enhanced ultrasonography for assessment of the muscular perfusion in canine appendicular regions.
Collapse
Affiliation(s)
- Juyeon Oh
- Department of Veterinary Medical Imaging, College of Veterinary Medicine, Chonnam National University, Gwangju 500-757, South Korea
| | | | | |
Collapse
|
31
|
Thomas KN, Cotter JD, Lucas SJE, Hill BG, van Rij AM. Reliability of contrast-enhanced ultrasound for the assessment of muscle perfusion in health and peripheral arterial disease. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:26-34. [PMID: 25308937 DOI: 10.1016/j.ultrasmedbio.2014.06.012] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2014] [Revised: 06/08/2014] [Accepted: 06/17/2014] [Indexed: 06/04/2023]
Abstract
We investigated the reliability of contrast-enhanced ultrasound (CEUS) in assessing calf muscle microvascular perfusion in health and disease. Response to a post-occlusive reactive hyperaemia test was repeated on two occasions >48 h apart in healthy young (28 ± 7 y) and elderly controls (70 ± 5 y), and in peripheral arterial disease patients (PAD, 69 ± 7 y; n = 10, 9 and 8 respectively). Overall, within-individual reliability was poor (coefficient of variation [CV] range: 15-87%); the most reliable parameter was time to peak (TTP, 15-48% CV). Nevertheless, TTP was twice as long in elderly controls and PAD compared to young (19.3 ± 10.4 and 22.0 ± 8.6 vs. 8.9 ± 6.2 s respectively; p < 0.01), and area under the curve for contrast intensity post-occlusion (a reflection of blood volume) was ∼50% lower in elderly controls (p < 0.01 versus PAD and young). Thus, CEUS assessment of muscle perfusion during reactive hyperaemia demonstrated poor reliability, yet still distinguished differences between PAD patients, elderly and young controls.
Collapse
Affiliation(s)
- Kate N Thomas
- Department of Surgical Sciences, Dunedin School of Medicine, University of Otago, Dunedin, New Zealand; School of Physical Education, Sport and Exercise Sciences, University of Otago, Dunedin, New Zealand
| | - James D Cotter
- School of Physical Education, Sport and Exercise Sciences, University of Otago, Dunedin, New Zealand
| | - Samuel J E Lucas
- Department of Physiology, University of Otago, Dunedin, New Zealand; School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Brigid G Hill
- Department of Surgical Sciences, Dunedin School of Medicine, University of Otago, Dunedin, New Zealand
| | - André M van Rij
- Department of Surgical Sciences, Dunedin School of Medicine, University of Otago, Dunedin, New Zealand.
| |
Collapse
|
32
|
The Correlation of Contrast-Enhanced Ultrasound and MRI Perfusion Quantitative Analysis in Rabbit VX2 Liver Cancer. Cell Biochem Biophys 2014; 70:1859-67. [DOI: 10.1007/s12013-014-0143-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
33
|
Evaluation of thyroid cancer in Chinese females with breast cancer by vascular endothelial growth factor (VEGF), microvessel density, and contrast-enhanced ultrasound (CEUS). Tumour Biol 2014; 35:6521-9. [DOI: 10.1007/s13277-014-1868-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2014] [Accepted: 03/18/2014] [Indexed: 01/08/2023] Open
|
34
|
Assessment of peripheral skeletal muscle microperfusion in a porcine model of peripheral arterial stenosis by steady-state contrast-enhanced ultrasound and Doppler flow measurement. J Vasc Surg 2014; 61:1312-20. [PMID: 24418637 DOI: 10.1016/j.jvs.2013.11.094] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2013] [Revised: 11/26/2013] [Accepted: 11/29/2013] [Indexed: 11/20/2022]
Abstract
OBJECTIVE Noninvasive measurement of peripheral muscle microperfusion could potentially improve diagnosis, management, and treatment of peripheral arterial disease (PAD) and thus improve patient care. Contrast-enhanced ultrasound (CEUS) as a noninvasive diagnostic tool allows quantification of muscle perfusion. Increasing data on bolus technique CEUS reflecting microperfusion are becoming available, but only limited data on steady-state CEUS for assessment of muscle microperfusion are available. Therefore, the aim of this study was to evaluate steady-state CEUS for assessment of peripheral muscle microperfusion in a PAD animal model. METHODS In a porcine animal model, peripheral muscle microperfusion was quantified by steady-state CEUS replenishment kinetics (mean transit time [mTT] and wash-in rate [WiR]) of the biceps femoris muscle during intravenous steady-state infusion of INN-sulfur hexafluoride (SonoVue; Bracco, Geneva, Switzerland). In addition, macroperfusion was quantified at the external femoral artery with a Doppler flow probe. Peripheral muscle microperfusion and Doppler flow measurements were performed bilaterally at rest and under adenosine stress (70 μg/kg body weight) before and after unilateral creation of a moderate external iliac artery stenosis. RESULTS All measurements could be performed completely in 10 pigs. Compared with baseline measurements, peripheral muscle microperfusion decreased significantly during adenosine stress (rest vs adenosine stress: mTT, 7.8 ± 3.3 vs 21.2 ± 17.8 s, P = .0006; WiR, 58.4 ± 38.1 vs 25.3 ± 15.6 arbitrary units [a.u.]/s, P < .0001; Doppler flow, 122.3 ± 31.4 vs 83.6 ± 28.1 mL/min, P = .0067) and after stenosis creation (no stenosis vs stenosis: mTT, 8.1 ± 3.1 vs 29.2 ± 18.0 s, P = .0469; WiR, 53.0 ± 22.7 vs 13.6 ± 8.4 a.u./s, P = .0156; Doppler flow, 124.2 ± 41.8 vs 65.9 ± 40.0 mL/min, P = .0313). After stenosis creation, adenosine stress led to a further significant decrease of peripheral muscle microperfusion but had no effect on macroperfusion (mTT, 29.2 ± 18.0 vs 56.3 ± 38.7 s, P = .0078; WiR, 13.6 ± 8.4 vs 6.0 ± 4.1 a.u./s, P = .0078; Doppler flow, 65.9 ± 40.0 vs 79.2 ± 29.6 mL/min, P = .8125). Receiver operating characteristic curves for the presence of inflow stenosis showed an excellent area under the curve of 0.93 for mTT at rest and 0.86 for Doppler flow. CONCLUSIONS Peripheral muscle microperfusion measurement by steady-state CEUS with replenishment kinetics is feasible and allows detection of muscle microperfusion changes caused by vasodilative stress alone or in combination with a moderate inflow stenosis. Steady-state CEUS offers superior diagnostic performance compared with Doppler flow measurements. Therefore, steady-state CEUS may prove to be a useful tool in diagnosis of PAD and for evaluation of new therapies.
Collapse
|