1
|
Ueki A, Harada S, Aoyagi M, Matsumoto H, Ueda R, Mizuguchi K, Méhes G, Nagamine K. Electric wiring of bacteria using redox polymers and selective measurement of metabolic activity in the presence of surrounding planktonic bacteria. Bioelectrochemistry 2024; 160:108779. [PMID: 39003947 DOI: 10.1016/j.bioelechem.2024.108779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Revised: 07/09/2024] [Accepted: 07/10/2024] [Indexed: 07/16/2024]
Abstract
Non-electroactive bacteria (n-EAB), constituting the majority of known bacteria to date, have been underutilized in electrochemical conversion technologies due to their lack of direct electron transfer to electrodes. In this study, we established an electric wiring between n-EAB (gram-positive Bacillus subtilis and gram-negative Escherichia coli) and an extracellular electrode via a ferrocene-polyethyleneimine-based redox polymer (Fc-PEI). Chronoamperometry recordings indicated that Fc-PEI can transfer intracellular electrons to the extracellular electrode regardless of the molecular organization of PEI (linear or branched) and the membrane structure of bacteria (gram-positive or -negative). As fluorescence staining suggested, Fc-PEI improves the permeability of the bacterial cell membrane, enabling electron carriers in the cell to react with Fc. In addition, experiments with Fc-immobilized electrodes without PEI suggested the existence of an alternative electron transfer pathway from B. subtilis to the extracellular Fc adsorbed onto the cell membrane. Furthermore, we proposed for the first time that the bacteria/Fc-linear PEI modified structure enables selective measurement of immobilized bacterial activity by physically blocking contact between the electrode surface and planktonic cells co-existing in the surrounding media. Such electrodes can be a powerful analytical tool for elucidating the metabolic activities of specific bacteria wired to the electrode even within complex bacterial communities.
Collapse
Affiliation(s)
- Aoba Ueki
- Graduate School of Organic Materials Science, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510, Japan
| | - Shoi Harada
- Faculty of Engineering, Department of Polymeric and Organic Materials Engineering, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510, Japan
| | - Marika Aoyagi
- Graduate School of Organic Materials Science, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510, Japan
| | - Hirotaka Matsumoto
- Graduate School of Organic Materials Science, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510, Japan
| | - Riku Ueda
- Faculty of Engineering, Department of Polymeric and Organic Materials Engineering, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510, Japan
| | - Kei Mizuguchi
- Graduate School of Organic Materials Science, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510, Japan
| | - Gábor Méhes
- Graduate School of Information, Production and Systems, Waseda University, 2-7 Hibikino, Wakamatsu, Kitakyushu, Fukuoka 808-0135, Japan
| | - Kuniaki Nagamine
- Graduate School of Organic Materials Science, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510, Japan; Faculty of Engineering, Department of Polymeric and Organic Materials Engineering, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510, Japan.
| |
Collapse
|
2
|
Kharkova AS, Medvedeva AS, Kuznetsova LS, Gertsen MM, Kolesov VV, Arlyapov VA, Reshetilov AN. A "2-in-1" Bioanalytical System Based on Nanocomposite Conductive Polymers for Early Detection of Surface Water Pollution. Polymers (Basel) 2024; 16:1431. [PMID: 38794624 PMCID: PMC11125136 DOI: 10.3390/polym16101431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 05/02/2024] [Accepted: 05/10/2024] [Indexed: 05/26/2024] Open
Abstract
This work proposes an approach to the formation of receptor elements for the rapid diagnosis of the state of surface waters according to two indicators: the biochemical oxygen demand (BOD) index and toxicity. Associations among microorganisms based on the bacteria P. yeei and yeast S. cerevisiae, as well as associations of the yeasts O. polymorpha and B. adeninivorans, were formed to evaluate these indicators, respectively. The use of nanocomposite electrically conductive materials based on carbon nanotubes, biocompatible natural polymers-chitosan and bovine serum albumin cross-linked with ferrocenecarboxaldehyde, neutral red, safranin, and phenosafranin-has made it possible to expand the analytical capabilities of receptor systems. Redox polymers were studied by IR spectroscopy and Raman spectroscopy, the contents of electroactive components were determined by atomic absorption spectroscopy, and electrochemical properties were studied by electrochemical impedance and cyclic voltammetry methods. Based on the proposed kinetic approach to modeling individual stages of bioelectrochemical processes, the chitosan-neutral red/CNT composite was chosen to immobilize the yeast association between O. polymorpha (ks = 370 ± 20 L/g × s) and B. adeninivorans (320 ± 30 L/g × s), and a bovine serum albumin (BSA)-neutral composite was chosen to immobilize the association between the yeast S. cerevisiae (ks = 130 ± 10 L/g × s) and the bacteria P. yeei red/CNT (170 ± 30 L/g × s). After optimizing the composition of the receptor systems, it was shown that the use of nanocomposite materials together with associations among microorganisms makes it possible to determine BOD with high sensitivity (with a lower limit of 0.6 mg/dm3) and detect the presence of a wide range of toxicants of both organic and inorganic origin. Both receptor elements were tested on water samples, showing a high correlation between the results of biosensor analysis of BOD and toxicity and the results of standard analytical methods. The results obtained show broad prospects for creating sensitive and portable bioelectrochemical sensors for the early warning of environmentally hazardous situations based on associations among microorganisms and nanocomposite materials.
Collapse
Affiliation(s)
- Anna S. Kharkova
- The Research Center «BioChemTech», Tula State University, 300012 Tula, Russia; (A.S.K.); (A.S.M.); (L.S.K.)
| | - Anastasia S. Medvedeva
- The Research Center «BioChemTech», Tula State University, 300012 Tula, Russia; (A.S.K.); (A.S.M.); (L.S.K.)
| | - Lyubov S. Kuznetsova
- The Research Center «BioChemTech», Tula State University, 300012 Tula, Russia; (A.S.K.); (A.S.M.); (L.S.K.)
| | - Maria M. Gertsen
- Laboratory of Soil Chemistry and Ecology, Tula State Lev Tolstoy Pedagogical University, 300026 Tula, Russia;
| | - Vladimir V. Kolesov
- Kotelnikov Institute of Radioengineering and Electronics (IRE) of Russian Academy of Sciences, 111250 Moscow, Russia;
| | - Vyacheslav A. Arlyapov
- The Research Center «BioChemTech», Tula State University, 300012 Tula, Russia; (A.S.K.); (A.S.M.); (L.S.K.)
| | - Anatoly N. Reshetilov
- Federal Research Center «Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences», G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, 142290 Pushchino, Russia;
| |
Collapse
|
3
|
Yudina NY, Kozlova TN, Bogachikhin DA, Kosarenina MM, Arlyapov VA, Alferov SV. Electrochemical Biosensors for Express Analysis of the Integral Toxicity of Polymer Materials. BIOSENSORS 2023; 13:1011. [PMID: 38131771 PMCID: PMC10742246 DOI: 10.3390/bios13121011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 11/24/2023] [Accepted: 12/01/2023] [Indexed: 12/23/2023]
Abstract
Biosensors based on an oxygen electrode, a mediator electrode, and a mediator microbial biofuel cell (MFC) using the bacteria Gluconobacter oxydans B-1280 were formed and tested to determine the integral toxicity. G. oxydans bacteria exhibited high sensitivity to the toxic effects of phenol, 2,4-dinitrophenol, salicylic and trichloroacetic acid, and a number of heavy metal ions. The system "G. oxydans bacteria-ferrocene-graphite-paste electrode" was superior in sensitivity to biosensors formed using an oxygen electrode and MFC, in particular regarding heavy metal ions (EC50 of Cr3+, Mn2+, and Cd2+ was 0.8 mg/dm3, 0.3 mg/dm3 and 1.6 mg/dm3, respectively). It was determined that the period of stable functioning of electrochemical systems during measurements was reduced by half (from 30 to 15 days) due to changes in the enzyme system of microbial cells when exposed to toxicants. Samples of the products made from polymeric materials were analyzed using developed biosensor systems and standard biotesting methods based on inhibiting the growth of duckweed Lemna minor, reducing the motility of bull sperm, and quenching the luminescence of the commercial test system "Ecolum". The developed bioelectrocatalytic systems were comparable in sensitivity to commercial biosensors, which made it possible to correlate the results and identify, by all methods, a highly toxic sample containing diphenylmethane-4,4'-diisocyanate according to GC-MS data.
Collapse
Affiliation(s)
- Natalia Yu. Yudina
- Chemistry Department, Federal State Budgetary Educational Establishment of Higher Education, Tula State University, 300012 Tula, Russia; (N.Y.Y.); (V.A.A.)
| | - Tatyana N. Kozlova
- Laboratory of Ecological and Medical Biotechnology, Tula State University, Friedrich Engels Street 157, 300012 Tula, Russia; (T.N.K.)
| | - Daniil A. Bogachikhin
- Laboratory of Ecological and Medical Biotechnology, Tula State University, Friedrich Engels Street 157, 300012 Tula, Russia; (T.N.K.)
| | - Maria M. Kosarenina
- Chemistry Department, Federal State Budgetary Educational Establishment of Higher Education, Tula State University, 300012 Tula, Russia; (N.Y.Y.); (V.A.A.)
| | - Vyacheslav A. Arlyapov
- Chemistry Department, Federal State Budgetary Educational Establishment of Higher Education, Tula State University, 300012 Tula, Russia; (N.Y.Y.); (V.A.A.)
| | - Sergey V. Alferov
- Laboratory of Ecological and Medical Biotechnology, Tula State University, Friedrich Engels Street 157, 300012 Tula, Russia; (T.N.K.)
| |
Collapse
|
4
|
Liu Y, Yang Y, Fan Y, Zhao Q, Gao G, Zhi J. Feasibility investigation and development of microbial electrochemical biosensors for marine pollution monitoring. Talanta 2023; 255:124204. [PMID: 36580811 DOI: 10.1016/j.talanta.2022.124204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Revised: 12/12/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022]
Abstract
Electrochemical biosensor, as a real-time and rapid detection method, has rarely been explored in marine monitoring. In present work, microbial electrochemical biosensors based on two design strategies: disperse system and integrated microbial electrode, were systematically discussed and their feasibility in marine biotoxicity assessment were investigated. An isolation method was initially investigated to eliminate the potential interference and detect the biological response accurately. The influence of water salinity on the current response was eliminated by adopting the salt-tolerant bacteria Staphylococcus aureus as test microorganism and buffer solution with sufficient ionic strength. The biotoxicity of heavy metal ions and pesticides were sensitively determined. Furthermore, a novel integrated microbial biosensor was designed by immobilizing S. aureus with a redox-active gel that consists of chitosan and poly (diallyl dimethyl ammonium chloride) mixture and confined potassium ferricyanide via electrostatic interaction. The IC50 values for Cu2+, Zn2+, Cr2O72- and Ni2+ were 3.01 mg/L, 1.34 mg/L, 7.64 mg/L and 9.41 mg/L, respectively. This work not only verified the feasibility of electrochemical biosensor in marine pollution monitoring, but also compared the pros and cons of two biosensor design strategies, which provide a guidance for the future development and application of marine monitoring devices based on electrochemical method.
Collapse
Affiliation(s)
- Yanran Liu
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Yajie Yang
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Yining Fan
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Qi Zhao
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Guanyue Gao
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China.
| | - Jinfang Zhi
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China.
| |
Collapse
|
5
|
Wu SC, Shih CC. Experimental validation of stability and applicability of Start Growth Time method for high-throughput bacterial ecotoxicity assessment. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:85050-85061. [PMID: 35789463 DOI: 10.1007/s11356-022-21812-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Accepted: 06/29/2022] [Indexed: 06/15/2023]
Abstract
Ecotoxicity assessments based on bacteria as model organisms are widely used for routine toxicity screening because it has the advantages of time-saving, high sensitivity, cost-effectiveness, and less ethical responsibility. Determination of ecotoxicity effect via bacterial growth can avoid the restriction of model bacteria selection and unique equipment requirements, but traditional viable cell count methods are relatively labor- and time-intensive. The Start Growth Time method (SGT) is a high-throughput and time-conserving method to determine the amount of viable bacterial cells. However, its usability and stability for ecotoxicity assessment are rarely studied. This study confirmed its applicability in terms of bacterial types (gram-positive and gram-negative), growth phases (middle exponential and early stationary phases), and simultaneous existence of dead cells (adjustment by flow cytometry). Our results verified that the stability of establishing SGT correlation is independent of the bacterial type and dead-cell portion. Moreover, we only observed the effect of growth phases on the slope value of established SGT correlation in Shewanella oneidensis, which suggests that preparing inoculum for the SGT method should be consistent in keeping its stability. Our results also elucidate that the SGT values and the live cell percentages meet the non-linear exponential correlation with high correlation coefficients from 0.97 to 0.99 for all the examined bacteria. The non-linear exponential correlation facilitates the application of the SGT method in the ecotoxicity assessment. Finally, applying the exponential SGT correlation to evaluate the ecotoxicity effect of copper ions on E. coli was experimentally validated. The SGT-based method would require about 6 to 7 h to finish the assessment and obtain an estimated EC50 at 2.27 ± 0.04 mM. This study demonstrates that the exponential SGT correlation can be a high-throughput, time-conversing, and wide-applicable method for bacterial ecotoxicity assessment.
Collapse
Affiliation(s)
- Siang Chen Wu
- Department of Environmental Engineering, National Chung Hsing University, CEE Building, Room 521, 145 Xingda Road, South Dist., Taichung, 40227, Taiwan.
| | - Chang-Chun Shih
- Department of Environmental Engineering, National Chung Hsing University, CEE Building, Room 521, 145 Xingda Road, South Dist., Taichung, 40227, Taiwan
| |
Collapse
|
6
|
Kharkova A, Arlyapov V, Medvedeva A, Lepikash R, Melnikov P, Reshetilov A. Mediator Microbial Biosensor Analyzers for Rapid Determination of Surface Water Toxicity. SENSORS (BASEL, SWITZERLAND) 2022; 22:8522. [PMID: 36366221 PMCID: PMC9655160 DOI: 10.3390/s22218522] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 11/02/2022] [Accepted: 11/03/2022] [Indexed: 06/16/2023]
Abstract
Microbial mediator biosensors for surface water toxicity determination make it possible to carry out an early assessment of the environmental object’s quality without time-consuming standard procedures based on standard test-organisms, and provide broad opportunities for receptor element modifying depending on the required operational parameters analyzer. Four microorganisms with broad substrate specificity and nine electron acceptors were used to form a receptor system for toxicity assessment. Ferrocene was the most effective mediator according to its high rate constant of interaction with the microorganisms (0.33 ± 0.01 dm3/(g × s) for yeast Saccharomyces cerevisiae). Biosensors were tested on samples containing four heavy metal ions (Cu2+, Zn2+, Pb2+, Cd2+), two phenols (phenol and p-nitrophenol), and three natural water samples. The «ferrocene- Escherichia coli» and «ferrocene-Paracoccus yeei, E. coli association» systems showed good operational stability with a relative standard deviation of 6.9 and 7.3% (14 measurements) and a reproducibility of 7 and 5.2% using copper (II) ions as a reference toxicant. Biosensor analysis with these systems was shown to highly correlate with the results of the standard method using Chlorella algae as a test object. Developed biosensors allow for a valuation of the polluted natural water’s impact on the ecosystem via an assessment of the influence on bacteria and yeast in the receptor system. The systems could be used in toxicological monitoring of natural waters.
Collapse
Affiliation(s)
- Anna Kharkova
- Department of Chemistry, Tula State University, 92 Lenin Avenue, Tula 300012, Russia
| | - Vyacheslav Arlyapov
- Department of Chemistry, Tula State University, 92 Lenin Avenue, Tula 300012, Russia
| | - Anastasia Medvedeva
- Department of Chemistry, Tula State University, 92 Lenin Avenue, Tula 300012, Russia
| | - Roman Lepikash
- Department of Chemistry, Tula State University, 92 Lenin Avenue, Tula 300012, Russia
| | - Pavel Melnikov
- M.V. Lomonosov Institute of Fine Chemical Technologies, MIREA—Russian Technological University, Prospect Vernadskogo 86, Moscow 119571, Russia
| | - Anatoly Reshetilov
- G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Federal Research Center “Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences” (FRC PSCBR), Russian Academy of Sciences, 5 Nauki Avenue, Moscow 142290, Russia
| |
Collapse
|
7
|
Azman N, Khairul WM, Sarbon N. A comprehensive review on biocompatible film sensor containing natural extract: Active/intelligent food packaging. Food Control 2022. [DOI: 10.1016/j.foodcont.2022.109189] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
8
|
Madej-Kiełbik L, Gzyra-Jagieła K, Jóźwik-Pruska J, Dziuba R, Bednarowicz A. Biopolymer Composites with Sensors for Environmental and Medical Applications. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7493. [PMID: 36363084 PMCID: PMC9659006 DOI: 10.3390/ma15217493] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 10/13/2022] [Accepted: 10/21/2022] [Indexed: 06/16/2023]
Abstract
One of the biggest economic and environmental sustainability problems is the over-reliance on petroleum chemicals in polymer production. This paper presents an overview of the current state of knowledge on biopolymers combined with biosensors in terms of properties, compounding methods and applications, with a focus on medical and environmental aspects. Therefore, this article is devoted to environmentally friendly polymer materials. The paper presents an overview of the current state of knowledge on biopolymers combined with biosensors in terms of properties, compounding methods and applications, with a special focus on medical and environmental aspects. The paper presents the current state of knowledge, as well as prospects. The article shows that biopolymers made from renewable raw materials are of great interest in various fields of science and industry. These materials not only replace existing polymers in many applications, but also provide new combinations of properties for new applications. Composite materials based on biopolymers are considered superior to traditional non-biodegradable materials due to their ability to degrade when exposed to environmental factors. The paper highlights the combination of polymers with nanomaterials which allows the preparation of chemical sensors, thus enabling their use in environmental or medical applications due to their biocompatibility and sensitivity. This review focuses on analyzing the state of research in the field of biopolymer-sensor composites.
Collapse
Affiliation(s)
- Longina Madej-Kiełbik
- Lukasiewicz Research Network—Lodz Institute of Technology, 19/27 M. Sklodowskiej-Curie Str., 90-570 Lodz, Poland
| | - Karolina Gzyra-Jagieła
- Lukasiewicz Research Network—Lodz Institute of Technology, 19/27 M. Sklodowskiej-Curie Str., 90-570 Lodz, Poland
- Faculty of Material Technologies and Textile Design, Lodz University of Technology, 116 Żeromskiego Street, 90-924 Lodz, Poland
| | - Jagoda Jóźwik-Pruska
- Lukasiewicz Research Network—Lodz Institute of Technology, 19/27 M. Sklodowskiej-Curie Str., 90-570 Lodz, Poland
| | - Radosław Dziuba
- Department of World Economy and European Integration, University of Lodz, 41/43 Rewolucji 1905 Str., 90-214 Lodz, Poland
| | - Anna Bednarowicz
- Lukasiewicz Research Network—Lodz Institute of Technology, 19/27 M. Sklodowskiej-Curie Str., 90-570 Lodz, Poland
- Faculty of Material Technologies and Textile Design, Lodz University of Technology, 116 Żeromskiego Street, 90-924 Lodz, Poland
| |
Collapse
|
9
|
Sabah M, Fethi A. Electrochemical Detection of Lead in Real Samples Using Carbon Nanostructure and Inactivated E. coli as Low-Cost Sensitive Biosensor with High Electrocatalytic Performance. Electrocatalysis (N Y) 2022. [DOI: 10.1007/s12678-022-00760-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
10
|
Khan S, Akrema, Qazi S, Ahmad R, Raza K, Rahisuddin. In Silico and Electrochemical Studies for a ZnO-CuO-Based Immunosensor for Sensitive and Selective Detection of E. coli. ACS OMEGA 2021; 6:16076-16085. [PMID: 34179653 PMCID: PMC8223399 DOI: 10.1021/acsomega.1c01959] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 06/01/2021] [Indexed: 12/04/2023]
Abstract
Escherichia coli is a harmful Gram-negative bacterium commonly found in the gut of warm-blooded organisms and affects millions of people annually worldwide. In this study, we have synthesized a ZnO-CuO nanocomposite (NC) by a co-precipitation method and characterized the as-synthesized NC using FTIR spectroscopy, XRD, Raman spectroscopy, and FESEM techniques. To fabricate the immunosensor, the ZnO-CuO NC composite was screen-printed on gold-plated electrodes followed by physisorption of the anti-LPS E. coli antibody. The biosensor was optimized for higher specificity and sensitivity. The immunosensor exhibited a high sensitivity (11.04 μA CFU mL-1) with a low detection limit of 2 CFU mL-1 with a redox couple. The improved performance of the immunosensor is attributed to the synergistic effect of the NC and the antilipopolysaccharide antibody against E. coli. The selectivity studies were also carried out with Staphylococcus aureus to assess the specificity of the immunosensor. Testing in milk samples was done by spiking the milk samples with different concentrations of E. coli to check the potential of this immunosensor. We further checked the affinity between ZnO-CuO NC with E. coli LPS and the anti-LPS antibody using molecular docking studies. Atomic charge computation and interaction analyses were performed to support our hypothesis. Our results discern that there is a strong correlation between molecular docking studies and electrochemical characterization. The interaction analysis further displays the strong affinity between the antibody-LPS complex when immobilized with a nanoparticle composite (ZnO-CuO).
Collapse
Affiliation(s)
- Summaiyya Khan
- Department
of Chemistry, Jamia Millia Islamia, New Delhi 110025, India
| | - Akrema
- Department
of Chemistry, Jamia Millia Islamia, New Delhi 110025, India
| | - Sahar Qazi
- Department
of Computer Science, Jamia Millia Islamia, New Delhi 110025, India
| | - Rafiq Ahmad
- Centre
for Nanoscience and Nanotechnology, Jamia
Millia Islamia, New Delhi 110025, India
| | - Khalid Raza
- Department
of Computer Science, Jamia Millia Islamia, New Delhi 110025, India
| | - Rahisuddin
- Department
of Chemistry, Jamia Millia Islamia, New Delhi 110025, India
| |
Collapse
|
11
|
Hassanvand Z, Jalali F, Nazari M, Parnianchi F, Santoro C. Carbon Nanodots in Electrochemical Sensors and Biosensors: A Review. ChemElectroChem 2020. [DOI: 10.1002/celc.202001229] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
| | | | - Maryam Nazari
- Faculty of Chemistry Razi University Kermanshah Iran
| | | | - Carlo Santoro
- Department of Chemical Engineering and Analytical Science The University of Manchester The Mill Sackville Street Manchester M13PAL UK
| |
Collapse
|
12
|
Eom H, Kang W, Kim S, Chon K, Lee YG, Oh SE. Improved toxicity analysis of heavy metal-contaminated water via a novel fermentative bacteria-based test kit. CHEMOSPHERE 2020; 258:127412. [PMID: 32947661 DOI: 10.1016/j.chemosphere.2020.127412] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 06/10/2020] [Accepted: 06/11/2020] [Indexed: 06/11/2023]
Abstract
The objective of this study was development of a simple and reliable microbial toxicity test based on fermentative bacteria to assess heavy metal (Hg2+, Cu2+, Cr6+, Ni2+, As5+, or Pb2+)-contaminated water. The dominant species of test organisms used in this study was a spore-forming fermentative bacterium, Clostridium guangxiense. Toxicity of water was assessed based on inhibition of fermentative gas production of the test organisms, which was analyzed via a syringe method. Overall, the fermentative bacteria-based test kits satisfactorily identified increased toxicity of water as water was contaminated with high amounts of heavy metals; however, levels of inhibition were dissimilar depending on the species of metals. Inhibitory effects of Hg2+, Cu2+, Cr6+, and Ni2+ were considerably greater than those of As5+ and Pb2+. The 24 h half-maximum effective concentrations (EC50) for Hg2+, Cu2+, Cr6+, Ni2+, As5+, and Pb2+ were analyzed to be 0.10, 0.51, 1.09, 3.61, 101.33, and 243.45 mg/L, respectively, confirming that Hg2+, Cu2+, Cr6+, and Ni2+ are more toxic to fermentative gas production than As5+ and Pb2+. The fermentative bacteria-based toxicity test represents an improvement over other existing toxicity tests because of ease of end-point measurement, high reproducibility, and favorable on-site field applicability. These advantages make the fermentative bacteria-based test suitable for simple and reliable toxicity screening for heavy metal-contaminated water.
Collapse
Affiliation(s)
- Heonseop Eom
- Department of Biological Environment, Kangwon National University, 192-1 Hyoja-dong, Gangwon-do, Chuncheon-si, 200-701, Republic of Korea
| | - Woochang Kang
- Department of Biological Environment, Kangwon National University, 192-1 Hyoja-dong, Gangwon-do, Chuncheon-si, 200-701, Republic of Korea
| | - Seunggyu Kim
- Department of Biological Environment, Kangwon National University, 192-1 Hyoja-dong, Gangwon-do, Chuncheon-si, 200-701, Republic of Korea
| | - Kangmin Chon
- Department of Environment Engineering, Kangwon National University, 192-1 Hyoja-dong, Gangwon-do, Chuncheon-si, 200-701, Republic of Korea
| | - Yong-Gu Lee
- Department of Environment Engineering, Kangwon National University, 192-1 Hyoja-dong, Gangwon-do, Chuncheon-si, 200-701, Republic of Korea
| | - Sang-Eun Oh
- Department of Biological Environment, Kangwon National University, 192-1 Hyoja-dong, Gangwon-do, Chuncheon-si, 200-701, Republic of Korea.
| |
Collapse
|
13
|
Yang Y, Liu Y, Chen Y, Wang Y, Shao P, Liu R, Gao G, Zhi J. A portable instrument for monitoring acute water toxicity based on mediated electrochemical biosensor: Design, testing and evaluation. CHEMOSPHERE 2020; 255:126964. [PMID: 32416391 DOI: 10.1016/j.chemosphere.2020.126964] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Revised: 04/29/2020] [Accepted: 05/01/2020] [Indexed: 06/11/2023]
Abstract
A water quality early-warning instrument for evaluating acute water toxicity based on the electrochemical biosensor, Model ETOX18-01, was developed and manufactured with the features of low current detection (0.1 nA), precise thermostatic control, self-cleaning as well as remote data transmission. A sensitive integrated microbial electrode, made up of a glass carbon electrode that was modified by an active biofilm consisting of Escherichia coli, thionine, carbon nanodots and chitosan, has been fabricated as the biosensor. To validate the performance, multiple real water samples and artificial water samples were tested by Model ETOX18-01, and compared with ISO standardized luminescent bacterial test simultaneously. The correlation between the Model ETOX18-01 and luminescent bacterial test for these water samples showed good determination coefficient (R2 = 0.9827). In addition, Model ETOX18-01 is more sensitive to colored metal ionic samples. With its characteristics of high sensitivity, excellent repeatability and easy operation, the instrument Model ETOX18-01 provides a promising tool for large-scale water environmental assessment, and has a potential application in evaluating the water quality and early risk warning.
Collapse
Affiliation(s)
- Yajie Yang
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Yanran Liu
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, PR China
| | - Yafei Chen
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Yu Wang
- Beijing Center for Physical and Chemical Analysis, Beijing, 100089, PR China
| | - Peng Shao
- Beijing Center for Physical and Chemical Analysis, Beijing, 100089, PR China
| | - Runze Liu
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, PR China
| | - Guanyue Gao
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China.
| | - Jinfang Zhi
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China.
| |
Collapse
|
14
|
Registration of BOD using Paracoccus yeei bacteria isolated from activated sludge. 3 Biotech 2020; 10:207. [PMID: 32346498 DOI: 10.1007/s13205-020-02199-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Accepted: 04/08/2020] [Indexed: 10/24/2022] Open
Abstract
This work investigated the properties of Paracoccus yeei VKM B-3302 bacteria isolated from activated sludge and immobilized in an N-vinylpyrrolidone-modified poly(vinyl alcohol) matrix. The developed hydrogel formed a network structure to enable the entrapment of microbial cells with their viability and biocatalytic properties preserved, which ensured the technological possibility of replicating expendable biosensor receptor elements. A new ratio of the components for the synthesis selected in this work enabled producing a copolymer of an earlier undescribed chemical structure, which can be efficiently used for immobilization of highly sensitive P. yeei bacteria. A biological oxygen demand (BOD) biosensor with these bacteria and matrix was shown to possess a long-time stability exceeding that described earlier, to have a broad substrate specificity and to exceed approximately tenfold the nearest analogues by its sensitivity and the lower boundary value of 0.05 mg/dm3. The biosensor enabled assays of water samples initially attributed to pure samples (the BOD range, 0.05-5.0 mg/dm3). BOD assays of water samples from various sources showed the use of the receptor element of this composition to enable the data that closely correlated with the standard method (R 2 = 0.9990).
Collapse
|
15
|
Fang D, Gao G, Yang Y, Wang Y, Gao L, Zhi J. Redox Mediator‐Based Microbial Biosensors for Acute Water Toxicity Assessment: A Critical Review. ChemElectroChem 2020. [DOI: 10.1002/celc.202000367] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Deyu Fang
- Key Laboratory of Photochemical Conversion and Optoelectronic MaterialsTechnical Institute of Physics and ChemistryChinese Academy of Sciences Beijing 100190 PR China
- Current address: Ningde Amperex Technology Limited (ATL) Ningde 352100 PR China
| | - Guanyue Gao
- Key Laboratory of Photochemical Conversion and Optoelectronic MaterialsTechnical Institute of Physics and ChemistryChinese Academy of Sciences Beijing 100190 PR China
- University of Chinese Academy of Sciences Beijing 100049 PR China
| | - Yajie Yang
- Key Laboratory of Photochemical Conversion and Optoelectronic MaterialsTechnical Institute of Physics and ChemistryChinese Academy of Sciences Beijing 100190 PR China
- University of Chinese Academy of Sciences Beijing 100049 PR China
| | - Yu Wang
- Beijing Center for Physical and Chemical Analysis Beijing 100089 PR China
| | - Lijuan Gao
- Beijing Center for Physical and Chemical Analysis Beijing 100089 PR China
| | - Jinfang Zhi
- Key Laboratory of Photochemical Conversion and Optoelectronic MaterialsTechnical Institute of Physics and ChemistryChinese Academy of Sciences Beijing 100190 PR China
- University of Chinese Academy of Sciences Beijing 100049 PR China
| |
Collapse
|
16
|
Yoon J, Shin M, Lee T, Choi JW. Highly Sensitive Biosensors Based on Biomolecules and Functional Nanomaterials Depending on the Types of Nanomaterials: A Perspective Review. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E299. [PMID: 31936530 PMCID: PMC7013709 DOI: 10.3390/ma13020299] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 01/02/2020] [Accepted: 01/07/2020] [Indexed: 12/13/2022]
Abstract
Biosensors are very important for detecting target molecules with high accuracy, selectivity, and signal-to-noise ratio. Biosensors developed using biomolecules such as enzymes or nucleic acids which were used as the probes for detecting the target molecules were studied widely due to their advantages. For example, enzymes can react with certain molecules rapidly and selectively, and nucleic acids can bind to their complementary sequences delicately in nanoscale. In addition, biomolecules can be immobilized and conjugated with other materials by surface modification through the recombination or introduction of chemical linkers. However, these biosensors have some essential limitations because of instability and low signal strength derived from the detector biomolecules. Functional nanomaterials offer a solution to overcome these limitations of biomolecules by hybridization with or replacing the biomolecules. Functional nanomaterials can give advantages for developing biosensors including the increment of electrochemical signals, retention of activity of biomolecules for a long-term period, and extension of investigating tools by using its unique plasmonic and optical properties. Up to now, various nanomaterials were synthesized and reported, from widely used gold nanoparticles to novel nanomaterials that are either carbon-based or transition-metal dichalcogenide (TMD)-based. These nanomaterials were utilized either by themselves or by hybridization with other nanomaterials to develop highly sensitive biosensors. In this review, highly sensitive biosensors developed from excellent novel nanomaterials are discussed through a selective overview of recently reported researches. We also suggest creative breakthroughs for the development of next-generation biosensors using the novel nanomaterials for detecting harmful target molecules with high sensitivity.
Collapse
Affiliation(s)
- Jinho Yoon
- Department of Chemical & Biomolecular Engineering, Sogang University, 35 Baekbeom-Ro, Mapo-Gu, Seoul 04107, Korea; (J.Y.); (M.S.)
- Department of Chemistry and Chemical Biology, Rutgers, The State University of New Jersey, Piscataway, NJ 08854, USA
| | - Minkyu Shin
- Department of Chemical & Biomolecular Engineering, Sogang University, 35 Baekbeom-Ro, Mapo-Gu, Seoul 04107, Korea; (J.Y.); (M.S.)
| | - Taek Lee
- Department of Chemical Engineering, Kwangwoon University, Wolgye-dong, Nowon-gu, Seoul 01899, Korea;
| | - Jeong-Woo Choi
- Department of Chemical & Biomolecular Engineering, Sogang University, 35 Baekbeom-Ro, Mapo-Gu, Seoul 04107, Korea; (J.Y.); (M.S.)
| |
Collapse
|
17
|
Kharkova A, Arlyapov V, Turovskaya A, Shvets V, Reshetilov A. A mediator microbial biosensor for assaying general toxicity. Enzyme Microb Technol 2020; 132:109435. [DOI: 10.1016/j.enzmictec.2019.109435] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2019] [Revised: 09/14/2019] [Accepted: 09/18/2019] [Indexed: 11/30/2022]
|
18
|
Gupta N, Renugopalakrishnan V, Liepmann D, Paulmurugan R, Malhotra BD. Cell-based biosensors: Recent trends, challenges and future perspectives. Biosens Bioelectron 2019; 141:111435. [PMID: 31238280 DOI: 10.1016/j.bios.2019.111435] [Citation(s) in RCA: 138] [Impact Index Per Article: 27.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Revised: 05/31/2019] [Accepted: 06/11/2019] [Indexed: 12/13/2022]
Abstract
Existing at the interface of biology and electronics, living cells have been in use as biorecognition elements (bioreceptors) in biosensors since the early 1970s. They are an interesting choice of bioreceptors as they allow flexibility in determining the sensing strategy, are cheaper than purified enzymes and antibodies and make the fabrication relatively simple and cost-effective. And with advances in the field of synthetic biology, microfluidics and lithography, many exciting developments have been made in the design of cell-based biosensors in the last about five years. 3D cell culture systems integrated with electrodes are now providing new insights into disease pathogenesis and physiology, while cardiomyocyte-integrated microelectrode array (MEA) technology is set to be standardized for the assessment of drug-induced cardiac toxicity. From cell microarrays for high-throughput applications to plasmonic devices for anti-microbial susceptibility testing and advent of microbial fuel cell biosensors, cell-based biosensors have evolved from being mere tools for detection of specific analytes to multi-parametric devices for real time monitoring and assessment. However, despite these advancements, challenges such as regeneration and storage life, heterogeneity in cell populations, high interference and high costs due to accessory instrumentation need to be addressed before the full potential of cell-based biosensors can be realized at a larger scale. This review summarizes results of the studies that have been conducted in the last five years toward the fabrication of cell-based biosensors for different applications with a comprehensive discussion on the challenges, future trends, and potential inputs needed for improving them.
Collapse
Affiliation(s)
- Niharika Gupta
- Department of Biotechnology, Delhi Technological University, Main Bawana Road, Delhi 110042, India
| | | | - Dorian Liepmann
- Department of Bioengineering, University of California, Berkeley, CA, USA
| | - Ramasamy Paulmurugan
- Department of Radiology, Cellular Pathway Imaging Laboratory, Stanford University School of Medicine, 3155 Porter Drive, Suite 2236, Palo Alto, CA, 94304, USA
| | - Bansi D Malhotra
- Department of Biotechnology, Delhi Technological University, Main Bawana Road, Delhi 110042, India.
| |
Collapse
|
19
|
Jiang Y, Wu J. Recent development in chitosan nanocomposites for surface-based biosensor applications. Electrophoresis 2019; 40:2084-2097. [PMID: 31081120 DOI: 10.1002/elps.201900066] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Revised: 05/03/2019] [Accepted: 05/06/2019] [Indexed: 01/16/2023]
Abstract
Recent years have witnessed ever expanding use of biosensors in the fields of environmental monitoring, homeland security, pharmaceutical, food and bioprocessing, and agricultural industries. To produce effective and reliable biosensors, good quality immobilization of biological recognition elements is critical. Chitosan and its nanocomposites emerge as an excellent immobilization matrix on biosensor surface. As a natural polysaccharide, chitosan has many useful characteristics, such as high permeability and mechanical strength, biocompatibility and non-toxicity, availability, and low cost. Due to the presence of amino and hydroxyl groups on chitosan, chitosan can easily crosslink with a variety of nanomaterials. This investigation of chitosan nanocomposite-based biosensors presents recent development and innovations in the preparation of chitosan nanocomposites in coordination with biosensors for various bio-detection applications, including chitosan nanocomposites formed with carbon nanomaterials, various inorganic and biological complexes. These chitosan nanocomposite based biosensors have demonstrated good sensitivity selectivity and stability for the detection of different types of targets ranging from glucose, proteins, DNAs, small biomolecules to bacteria. It is in our hope that this review will offer guidance for the development of novel biosensors and open up opportunities in the field of biosensor research.
Collapse
Affiliation(s)
- Yu Jiang
- Electrical and Computer Engineering, The University of Tennessee, Knoxville, USA
| | - Jayne Wu
- Electrical and Computer Engineering, The University of Tennessee, Knoxville, USA
| |
Collapse
|
20
|
Idris AO, Mabuba N, Arotiba OA. An Exfoliated Graphite-Based Electrochemical Immunosensor on a Dendrimer/Carbon Nanodot Platform for the Detection of Carcinoembryonic Antigen Cancer Biomarker. BIOSENSORS 2019; 9:E39. [PMID: 30857164 PMCID: PMC6468524 DOI: 10.3390/bios9010039] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Revised: 03/01/2019] [Accepted: 03/03/2019] [Indexed: 11/17/2022]
Abstract
An electrochemical immunosensor for the quantification of carcinoembryonic antigen (CEA) using a nanocomposite of polypropylene imine dendrimer (PPI) and carbon nanodots (CNDTs) on an exfoliated graphite electrode (EG) is reported. The carbon nanodots were prepared by pyrolysis of oats. The nanocomposites (PPI and CNDTs) were characterized using X-ray powder diffraction (XRD), Raman spectroscopy, Fourier transform infrared spectroscopy (FTIR), high-resolution transmission electron microscopy (HRTEM) and scanning electron microscopy (SEM). The proposed immunosensor was prepared on an exfoliated graphite electrode sequentially by drop coating CNDTs, the electrodeposition of G2-PPI (generation 2 poly (propylene imine) dendrimer), the immobilization of anti-CEA on the modified electrode for 80 min at 35 °C, and dropping of bovine serum albumin (BSA) to minimize non-specific binding sites. Cyclic voltammetry was used to characterize each stage of the fabrication of the immunosensor. The proposed immunosensor detected CEA within a concentration range of 0.005 to 300 ng/mL with a detection limit of 0.00145 ng/mL by using differential pulse voltammetry (DPV). The immunosensor displayed good stability and was also selective in the presence of some interference species such as ascorbic acid, glucose, alpha-fetoprotein, prostate-specific antigen and human immunoglobulin. Furthermore, the fabricated immunosensor was applied in the quantification of CEA in a human serum sample, indicating its potential for real sample analysis.
Collapse
Affiliation(s)
- Azeez O Idris
- Department of Applied Chemistry, University of Johannesburg, Doornfontein 2028, Johannesburg, South Africa.
| | - Nonhlangabezo Mabuba
- Department of Applied Chemistry, University of Johannesburg, Doornfontein 2028, Johannesburg, South Africa.
- Centre for Nanomaterials Science Research, University of Johannesburg, Doornfontein 2028, Johannesburg, South Africa.
| | - Omotayo A Arotiba
- Department of Applied Chemistry, University of Johannesburg, Doornfontein 2028, Johannesburg, South Africa.
- Centre for Nanomaterials Science Research, University of Johannesburg, Doornfontein 2028, Johannesburg, South Africa.
| |
Collapse
|
21
|
Yang Y, Fang Z, Yu YY, Wang YZ, Naraginti S, Yong YC. A mediator-free whole-cell electrochemical biosensing system for sensitive assessment of heavy metal toxicity in water. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2019; 79:1071-1080. [PMID: 31070587 DOI: 10.2166/wst.2019.101] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
A bioelectrochemical sensing system (BES) based on electroactive bacteria (EAB) has been used as a new and promising tool for water toxicity assessment. However, most EAB can reduce heavy metals, which usually results in low toxicity response. Herein, a starvation pre-incubation strategy was developed which successfully avoided the metal reduction during the toxicity sensing period. By integrating this starvation pre-incubation procedure with the amperometric BES, a sensitive, robust and mediator-free biosensing method for heavy metal toxicity assessment was developed. Under the optimized conditions, the IC50 (half maximal inhibitory concentration) values for Cu2+, Ni2+, Cd2+, and Cr6+ obtained were 0.35, 3.49, 6.52, 2.48 mg L-1, respectively. The measurement with real water samples also suggested this method was reliable for practical application. This work demonstrates that it is feasible to use EAB for heavy metal toxicity assessment and provides a new tool for water toxicity warning.
Collapse
Affiliation(s)
- Yuan Yang
- Biofuels Institute, School of Environment and Safety Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang, Jiangsu 212013, China E-mail:
| | - Zhen Fang
- Biofuels Institute, School of Environment and Safety Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang, Jiangsu 212013, China E-mail:
| | - Yang-Yang Yu
- Biofuels Institute, School of Environment and Safety Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang, Jiangsu 212013, China E-mail:
| | - Yan-Zhai Wang
- Biofuels Institute, School of Environment and Safety Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang, Jiangsu 212013, China E-mail:
| | - Saraschandra Naraginti
- Biofuels Institute, School of Environment and Safety Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang, Jiangsu 212013, China E-mail:
| | - Yang-Chun Yong
- Biofuels Institute, School of Environment and Safety Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang, Jiangsu 212013, China E-mail: ; Zhenjiang Key Laboratory for Advanced Sensing Materials and Devices, School of Mechanical Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang, Jiangsu 212013, China
| |
Collapse
|
22
|
Mi Y, Tao X, Zhang X, Si Y. Acute biotoxicity assessment of heavy metals in sewage sludge based on the glucose consumption of Escherichia coli. ROYAL SOCIETY OPEN SCIENCE 2019; 6:181769. [PMID: 30800404 PMCID: PMC6366162 DOI: 10.1098/rsos.181769] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Accepted: 12/11/2018] [Indexed: 05/31/2023]
Abstract
As a simple and feasible method for acute biotoxicity assessment, personal glucose meter (PGM) can be successfully applied in the early warning of environmental pollutants in sewage. In this paper, the acute biotoxicity of single and joint heavy metals in sewage and real sludge samples was systematically described based on the glucose metabolism of Escherichia coli (E. coli). Results indicated that the biotoxicity order of five single heavy metals in sewage was Hg2+ > As3+ > Cu2+ > Zn2+ > Cd2+. The joint heavy metals of Cu2+ + Zn2+, Cu2+ + Cd2+, and Cu2+ + Hg2+ produced synergistic effects, while Cu2+ + As3+ and Cd2+ + Zn2+ possessed antagonistic effects for the combined biotoxicity. In spiked sludge, Cd2+ and Zn2+ owned higher biotoxicity than Cu2+ and As3+. Notably, the electroplate factory and housing estate sludge respectively showed the highest and lowest inhibition rates as 57.4% and 17.7% under the real sludge biotoxicity assessment. These results demonstrated that PGM was a sensitive and portable method, which could be widely used for acute biotoxicity assessment of heavy metals in sewage sludge.
Collapse
Affiliation(s)
| | | | | | - Youbin Si
- Anhui Province Key Laboratory of FarmLand Ecological Conservation and Pollution Prevention, School of Resources and Environment, Anhui Agricultural University, Hefei 230036, China
| |
Collapse
|
23
|
Bioelectrochemical biosensor for water toxicity detection: generation of dual signals for electrochemical assay confirmation. Anal Bioanal Chem 2017; 410:1231-1236. [PMID: 28965160 DOI: 10.1007/s00216-017-0656-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 09/13/2017] [Accepted: 09/19/2017] [Indexed: 12/11/2022]
Abstract
Toxicity assessment of water is of great important to the safety of human health and to social security because of more and more toxic compounds that are spilled into the aquatic environment. Therefore, the development of fast and reliable toxicity assessment methods is of great interest and attracts much attention. In this study, by using the electrochemical activity of Shewanella oneidensis MR-1 cells as the toxicity indicator, 3,5-dichlorophenol (DCP) as the model toxic compound, a new biosensor for water toxicity assessment was developed. Strikingly, the presence of DCP in the water significantly inhibited the maximum current output of the S. oneidensis MR-1 in a three-electrode system and also retarded the current evolution by the cells. Under the optimized conditions, the maximum current output of the biosensor was proportional to the concentration of DCP up to 30 mg/L. The half maximal inhibitory concentration of DCP determined by this biosensor is about 14.5 mg/L. Furthermore, simultaneous monitoring of the retarded time (Δt) for current generation allowed the identification of another biosensor signal in response to DCP which could be employed to verify the electrochemical result by dual confirmation. Thus, the present study has provided a reliable and promising approach for water quality assessment and risk warning of water toxicity.
Collapse
|