1
|
Pankratov D, Hidalgo Martinez S, Karman C, Gerzhik A, Gomila G, Trashin S, Boschker HTS, Geelhoed JS, Mayer D, De Wael K, J R Meysman F. The organo-metal-like nature of long-range conduction in cable bacteria. Bioelectrochemistry 2024; 157:108675. [PMID: 38422765 DOI: 10.1016/j.bioelechem.2024.108675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 02/22/2024] [Accepted: 02/24/2024] [Indexed: 03/02/2024]
Abstract
Cable bacteria are filamentous, multicellular microorganisms that display an exceptional form of biological electron transport across centimeter-scale distances. Currents are guided through a network of nickel-containing protein fibers within the cell envelope. Still, the mechanism of long-range conduction remains unresolved. Here, we characterize the conductance of the fiber network under dry and wet, physiologically relevant, conditions. Our data reveal that the fiber conductivity is high (median value: 27 S cm-1; range: 2 to 564 S cm-1), does not show any redox signature, has a low thermal activation energy (Ea = 69 ± 23 meV), and is not affected by humidity or the presence of ions. These features set the nickel-based conduction mechanism in cable bacteria apart from other known forms of biological electron transport. As such, conduction resembles that of an organic semi-metal with a high charge carrier density. Our observation that biochemistry can synthesize an organo-metal-like structure opens the way for novel bio-based electronic technologies.
Collapse
Affiliation(s)
- Dmitrii Pankratov
- Geobiology Group, Microbial Systems Technology Excellence Centre, Department of Biology, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk, Belgium; A-Sense Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerpen, Belgium
| | - Silvia Hidalgo Martinez
- Geobiology Group, Microbial Systems Technology Excellence Centre, Department of Biology, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk, Belgium
| | - Cheryl Karman
- Geobiology Group, Microbial Systems Technology Excellence Centre, Department of Biology, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk, Belgium; A-Sense Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerpen, Belgium
| | - Anastasia Gerzhik
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich, 52428 Jülich, Germany
| | - Gabriel Gomila
- Nanoscale Bioelectric Characterization Group, Institute for Bioengineering of Catalunya (IBEC), The Barcelona Institute of Science and Technology, Baldiri i Reixac 15-21, 08028 Barcelona, Spain; Department of Electronics and Biomedical Engineering, Universitat de Barcelona, Martí i Franqués 1, 08028 Barcelona, Spain
| | - Stanislav Trashin
- A-Sense Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerpen, Belgium
| | - Henricus T S Boschker
- Geobiology Group, Microbial Systems Technology Excellence Centre, Department of Biology, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk, Belgium; Department of Biotechnology, Delft University of Technology, Van der Maasweg 9, 2629HZ Delft, the Netherlands
| | - Jeanine S Geelhoed
- Geobiology Group, Microbial Systems Technology Excellence Centre, Department of Biology, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk, Belgium
| | - Dirk Mayer
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich, 52428 Jülich, Germany
| | - Karolien De Wael
- A-Sense Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerpen, Belgium
| | - Filip J R Meysman
- Geobiology Group, Microbial Systems Technology Excellence Centre, Department of Biology, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk, Belgium; Department of Biotechnology, Delft University of Technology, Van der Maasweg 9, 2629HZ Delft, the Netherlands.
| |
Collapse
|
2
|
Colin C, Levallois P, Botsos-Margerit U, Clément F, Zigah D, Arbault S. Easy cleaning plus stable activation of glassy carbon electrode surface by oxygen plasma. Bioelectrochemistry 2023; 154:108551. [PMID: 37677984 DOI: 10.1016/j.bioelechem.2023.108551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 08/24/2023] [Accepted: 08/25/2023] [Indexed: 09/09/2023]
Abstract
Glassy carbon (GC) electrodes are widely used in electroanalytical applications especially in bioelectrochemistry. Their use starts with an efficient surface cleaning and activation protocol, mostly based on surface polishing steps. We studied the use of an oxygen plasma exposure of GC electrodes to replace common polishing procedures. The cyclic voltammetry (CV) responses of ferrocyanide and ferrocene-dimethanol were used to compare brand new, surface-polished and plasma-treated GC electrodes. Plasma treatment induces CV responses with improved features, close to theoretical values, as compared to other methods. The plasma effects were quasi-stable over a week when electrodes were stored in water, this being explained by increased surface energy and hydrophilicity. Furthermore, when electroreduction of diazonium was performed on GC electrodes, the surface blockade could be removed by the plasma. Thus, a short oxygen plasma treatment is prone to replace polishing protocols, that display person-dependent efficiency, in most of the experiments with GC electrodes.
Collapse
Affiliation(s)
- Camille Colin
- Univ. Bordeaux, Bordeaux INP, CNRS, ISM, UMR 5255, F-33400 Talence, France
| | - Pierre Levallois
- Univ. Bordeaux, Bordeaux INP, CNRS, ISM, UMR 5255, F-33400 Talence, France
| | | | - Franck Clément
- Université de Pau et des Pays de l'Adour, E2S UPPA, CNRS, IPREM UMR 5254, 64600 Anglet, France
| | - Dodzi Zigah
- Univ. Bordeaux, Bordeaux INP, CNRS, ISM, UMR 5255, F-33400 Talence, France; Institut de Chimie des Milieux et Matériaux de Poitiers (IC2MP), Université de Poitiers, CNRS, F-86073 Poitiers, France.
| | - Stéphane Arbault
- Univ. Bordeaux, Bordeaux INP, CNRS, ISM, UMR 5255, F-33400 Talence, France; Univ. Bordeaux, CNRS, Bordeaux INP, CBMN, UMR 5248, F-33600 Pessac, France.
| |
Collapse
|
3
|
McCann C, Gilpin V, Scott C, Pourshahidi LK, Gill CIR, Davis J. Moving towards in pouch diagnostics for ostomy patients: exploiting the versatility of laser induced graphene sensors. JOURNAL OF MATERIALS SCIENCE 2023; 58:14207-14219. [PMID: 37745186 PMCID: PMC10511578 DOI: 10.1007/s10853-023-08881-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Accepted: 08/18/2023] [Indexed: 09/26/2023]
Abstract
The development of a 3D printed sensor for direct incorporation within stoma pouches is described. Laser induced graphene scribed on either side of polyimide film served as the basis of a 2 electrode configuration that could be integrated within a disposable pouch sensor for the periodic monitoring of ileostomy fluid pH. The graphene sensors were characterised using electron microscopy, Raman spectroscopy, DekTak profilometry with the electrochemical properties investigated using both cyclic and square wave voltammetry. Adsorbed riboflavin was employed as a biocompatible redox probe for the voltammetric measurement of pH. The variation in peak position with pH was found to be linear over pH 3-8 with a sub Nernstian response (43 mV/pH). The adsorbed probe was found to be reversible and exhibited minimal leaching through repeated scanning. The performance of the system was assessed in a heterogeneous bacterial fermentation mixture simulating ileostomy fluid with the pH recorded before and after 96 h incubation. The peak profile in the bacterial medium provided an unambiguous signal free from interference with the calculated pH before and after incubation (pH 5.3 to 3.66) in good agreement with that obtained with commercial pH probes. Graphical abstract Supplementary Information The online version contains supplementary material available at 10.1007/s10853-023-08881-x.
Collapse
Affiliation(s)
- Conor McCann
- School of Engineering, Ulster University, Belfast, Northern Ireland
| | - Victoria Gilpin
- School of Engineering, Ulster University, Belfast, Northern Ireland
| | - Cameron Scott
- School of Engineering, Ulster University, Belfast, Northern Ireland
| | | | - Chris. I. R. Gill
- School of Biomedical Sciences, Ulster University, Coleraine, Northern Ireland
| | - James Davis
- School of Engineering, Ulster University, Belfast, Northern Ireland
| |
Collapse
|