1
|
Marcotulli M, Barbetta A, Scarpa E, Bini F, Marinozzi F, Ruocco G, Casciola CM, Scognamiglio C, Carugo D, Cidonio G. Jingle Cell Rock: Steering Cellular Activity With Low-Intensity Pulsed Ultrasound (LIPUS) to Engineer Functional Tissues in Regenerative Medicine. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:1973-1986. [PMID: 39289118 DOI: 10.1016/j.ultrasmedbio.2024.08.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 08/15/2024] [Accepted: 08/23/2024] [Indexed: 09/19/2024]
Abstract
Acoustic manipulation or perturbation of biological soft matter has emerged as a promising clinical treatment for a number of applications within regenerative medicine, ranging from bone fracture repair to neuromodulation. The potential of ultrasound (US) endures in imparting mechanical stimuli that are able to trigger a cascade of molecular signals within unscathed cells. Particularly, low-intensity pulsed ultrasound (LIPUS) has been associated with bio-effects such as activation of specific cellular pathways and alteration of cell morphology and gene expression, the extent of which can be modulated by fine tuning of LIPUS parameters including intensity, frequency and exposure time. Although the molecular mechanisms underlying LIPUS are not yet fully elucidated, a number of studies clearly define the modulation of specific ultrasonic parameters as a means to guide the differentiation of a specific set of stem cells towards adult and fully differentiated cell types. Herein, we outline the applications of LIPUS in regenerative medicine and the in vivo and in vitro studies that have confirmed the unbounded clinical potential of this platform. We highlight the latest developments aimed at investigating the physical and biological mechanisms of action of LIPUS, outlining the most recent efforts in using this technology to aid tissue engineering strategies for repairing tissue or modelling specific diseases. Ultimately, we detail tissue-specific applications harnessing LIPUS stimuli, offering insights over the engineering of new constructs and therapeutic modalities. Overall, we aim to lay the foundation for a deeper understanding of the mechanisms governing LIPUS-based therapy, to inform the development of safer and more effective tissue regeneration strategies in the field of regenerative medicine.
Collapse
Affiliation(s)
- Martina Marcotulli
- 3D Microfluidic Bioprinting Lab, Center for Life Nano- & Neuro-Science (CLN2S), Italian Institute of Technology (IIT), Rome, Italy; Department of Biochemical Sciences, Sapienza University of Rome, Rome, Italy; Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Oxford, UK
| | - Andrea Barbetta
- Department of Chemistry, Sapienza University of Rome, Rome, Italy
| | - Edoardo Scarpa
- Infection Dynamics Laboratory, Department of Pharmaceutical Sciences, University of Milan, Milan, Italy; National Institute of Molecular Gentics (INGM), Milan, Italy; Bone and Joint Research Group, Centre for Human Development, Stem Cells and Regeneration, Institute of Developmental Sciences, University of Southampton, Southampton, UK
| | - Fabiano Bini
- Department of Mechanical and Aerospace Engineering (DIMA), Sapienza University of Rome, Rome, Italy
| | - Franco Marinozzi
- Department of Mechanical and Aerospace Engineering (DIMA), Sapienza University of Rome, Rome, Italy
| | - Giancarlo Ruocco
- 3D Microfluidic Bioprinting Lab, Center for Life Nano- & Neuro-Science (CLN2S), Italian Institute of Technology (IIT), Rome, Italy
| | - Carlo Massimo Casciola
- Department of Mechanical and Aerospace Engineering (DIMA), Sapienza University of Rome, Rome, Italy
| | - Chiara Scognamiglio
- 3D Microfluidic Bioprinting Lab, Center for Life Nano- & Neuro-Science (CLN2S), Italian Institute of Technology (IIT), Rome, Italy
| | - Dario Carugo
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Oxford, UK
| | - Gianluca Cidonio
- 3D Microfluidic Bioprinting Lab, Center for Life Nano- & Neuro-Science (CLN2S), Italian Institute of Technology (IIT), Rome, Italy; Bone and Joint Research Group, Centre for Human Development, Stem Cells and Regeneration, Institute of Developmental Sciences, University of Southampton, Southampton, UK; Department of Mechanical and Aerospace Engineering (DIMA), Sapienza University of Rome, Rome, Italy.
| |
Collapse
|
2
|
Khandpur U, Haile B, Makary MS. Early-Stage Renal Cell Carcinoma Locoregional Therapies: Current Approaches and Future Directions. Clin Med Insights Oncol 2024; 18:11795549241285390. [PMID: 39435052 PMCID: PMC11492234 DOI: 10.1177/11795549241285390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2024] [Accepted: 09/03/2024] [Indexed: 10/23/2024] Open
Abstract
Renal cell carcinoma (RCC) is the most common primary renal malignancy. Prevalence of RCC in developed countries has slowly increased. Although partial or total nephrectomy has been the first-line treatment for early-stage RCC, improved or similar safety and treatment outcomes with locoregional therapies have challenged this paradigm. In this review, we explore locoregional techniques for early-stage RCC, including radiofrequency ablation, cryoablation, and microwave ablation with a focus on procedural technique, patient selection, and safety/treatment outcomes. Furthermore, we discuss future advances and novel techniques, including radiomics, combination therapy, high-intensity focused ultrasound, and catheter-directed techniques.
Collapse
Affiliation(s)
- Umang Khandpur
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Bereket Haile
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Mina S Makary
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| |
Collapse
|
3
|
Lari S, Kohandel M, Kwon HJ. Model based deep learning method for focused ultrasound pathway scanning. Sci Rep 2024; 14:20042. [PMID: 39198623 PMCID: PMC11358149 DOI: 10.1038/s41598-024-70689-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Accepted: 08/20/2024] [Indexed: 09/01/2024] Open
Abstract
The primary purpose of high-intensity focused ultrasound (HIFU), a non-invasive medical therapy, is to precisely target and ablate tumors by focusing high-frequency ultrasound from an external power source. A series of ablations must be performed in order to treat a big volume of tumors, as a single ablation can only remove a small amount of tissue. To maximize therapeutic efficacy while minimizing adverse side effects such as skin burns, preoperative treatment planning is essential in determining the focal site and sonication duration for each ablation. Here, we introduce a machine learning-based approach for designing HIFU treatment plans, which makes use of a map of the material characteristics unique to a patient alongside an accurate thermal simulation. A numerical model was employed to solve the governing equations of HIFU process and to simulate the HIFU absorption mechanism, including ensuing heat transfer process and the temperature rise during the sonication period. To validate the accuracy of this numerical model, a series of tests was conducted using ex vivo bovine liver. The findings indicate that the developed models properly represent the considerable variances observed in tumor geometrical shapes and proficiently generate well-defined closed treated regions based on imaging data. The proposed strategy facilitated the formulation of high-quality treatment plans, with an average tissue over- or under-treatment rate of less than 0.06%. The efficacy of the numerical model in accurately predicting the heating process of HIFU, when combined with machine learning techniques, was validated through quantitative comparison with experimental data. The proposed approach in cooperation with HIFU simulation holds the potential to enhance presurgical HIFU plan.
Collapse
Affiliation(s)
- Salman Lari
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Mohammad Kohandel
- Department of Applied Mathematics, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Hyock Ju Kwon
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
4
|
Campbell WA, Makary MS. Advances in Image-Guided Ablation Therapies for Solid Tumors. Cancers (Basel) 2024; 16:2560. [PMID: 39061199 PMCID: PMC11274819 DOI: 10.3390/cancers16142560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2024] [Revised: 06/26/2024] [Accepted: 07/10/2024] [Indexed: 07/28/2024] Open
Abstract
Image-guided solid tumor ablation methods have significantly advanced in their capability to target primary and metastatic tumors. These techniques involve noninvasive or percutaneous insertion of applicators to induce thermal, electrochemical, or mechanical stress on malignant tissue to cause tissue destruction and apoptosis of the tumor margins. Ablation offers substantially lower risks compared to traditional methods. Benefits include shorter recovery periods, reduced bleeding, and greater preservation of organ parenchyma compared to surgical intervention. Due to the reduced morbidity and mortality, image-guided tumor ablation offers new opportunities for treatment in cancer patients who are not candidates for resection. Currently, image-guided ablation techniques are utilized for treating primary and metastatic tumors in various organs with both curative and palliative intent, including the liver, pancreas, kidneys, thyroid, parathyroid, prostate, lung, breast, bone, and soft tissue. The invention of new equipment and techniques is expanding the criteria of eligible patients for therapy, as now larger and more high-risk tumors near critical structures can be ablated. This article provides an overview of the different imaging modalities, noninvasive, and percutaneous ablation techniques available and discusses their applications and associated complications across various organs.
Collapse
Affiliation(s)
- Warren A. Campbell
- Division of Vascular and Interventional Radiology, Department of Radiology, University of Virginia, Charlottesville, VA 22903, USA
| | - Mina S. Makary
- Division of Vascular and Interventional Radiology, Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH 43210, USA
| |
Collapse
|
5
|
Izhiman Y, Esfandiari L. Emerging role of extracellular vesicles and exogenous stimuli in molecular mechanisms of peripheral nerve regeneration. Front Cell Neurosci 2024; 18:1368630. [PMID: 38572074 PMCID: PMC10989355 DOI: 10.3389/fncel.2024.1368630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Accepted: 02/29/2024] [Indexed: 04/05/2024] Open
Abstract
Peripheral nerve injuries lead to significant morbidity and adversely affect quality of life. The peripheral nervous system harbors the unique trait of autonomous regeneration; however, achieving successful regeneration remains uncertain. Research continues to augment and expedite successful peripheral nerve recovery, offering promising strategies for promoting peripheral nerve regeneration (PNR). These include leveraging extracellular vesicle (EV) communication and harnessing cellular activation through electrical and mechanical stimulation. Small extracellular vesicles (sEVs), 30-150 nm in diameter, play a pivotal role in regulating intercellular communication within the regenerative cascade, specifically among nerve cells, Schwann cells, macrophages, and fibroblasts. Furthermore, the utilization of exogenous stimuli, including electrical stimulation (ES), ultrasound stimulation (US), and extracorporeal shock wave therapy (ESWT), offers remarkable advantages in accelerating and augmenting PNR. Moreover, the application of mechanical and electrical stimuli can potentially affect the biogenesis and secretion of sEVs, consequently leading to potential improvements in PNR. In this review article, we comprehensively delve into the intricacies of cell-to-cell communication facilitated by sEVs and the key regulatory signaling pathways governing PNR. Additionally, we investigated the broad-ranging impacts of ES, US, and ESWT on PNR.
Collapse
Affiliation(s)
- Yara Izhiman
- Esfandiari Laboratory, Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, OH, United States
| | - Leyla Esfandiari
- Esfandiari Laboratory, Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, OH, United States
- Department of Environmental and Public Health Sciences, College of Medicine, University of Cincinnati, Cincinnati, OH, United States
- Department of Electrical and Computer Engineering, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, OH, United States
| |
Collapse
|
6
|
Wu X, Sanders JL, Dundar MM, Oralkan Ö. Deep-Learning-Based High-Intensity Focused Ultrasound Lesion Segmentation in Multi-Wavelength Photoacoustic Imaging. Bioengineering (Basel) 2023; 10:1060. [PMID: 37760164 PMCID: PMC10526078 DOI: 10.3390/bioengineering10091060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 09/01/2023] [Accepted: 09/05/2023] [Indexed: 09/29/2023] Open
Abstract
Photoacoustic (PA) imaging can be used to monitor high-intensity focused ultrasound (HIFU) therapies because ablation changes the optical absorption spectrum of the tissue, and this change can be detected with PA imaging. Multi-wavelength photoacoustic (MWPA) imaging makes this change easier to detect by repeating PA imaging at multiple optical wavelengths and sampling the optical absorption spectrum more thoroughly. Real-time pixel-wise classification in MWPA imaging can assist clinicians in monitoring HIFU lesion formation and will be a crucial milestone towards full HIFU therapy automation based on artificial intelligence. In this paper, we present a deep-learning-based approach to segment HIFU lesions in MWPA images. Ex vivo bovine tissue is ablated with HIFU and imaged via MWPA imaging. The acquired MWPA images are then used to train and test a convolutional neural network (CNN) for lesion segmentation. Traditional machine learning algorithms are also trained and tested to compare with the CNN, and the results show that the performance of the CNN significantly exceeds traditional machine learning algorithms. Feature selection is conducted to reduce the number of wavelengths to facilitate real-time implementation while retaining good segmentation performance. This study demonstrates the feasibility and high performance of the deep-learning-based lesion segmentation method in MWPA imaging to monitor HIFU lesion formation and the potential to implement this method in real time.
Collapse
Affiliation(s)
- Xun Wu
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA;
| | - Jean L. Sanders
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA;
| | - M. Murat Dundar
- Computer and Information Science Department, Indiana University—Purdue University, Indianapolis, IN 46202, USA;
| | - Ömer Oralkan
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA;
| |
Collapse
|
7
|
Zubair M, Adams MS, Diederich CJ. An endoluminal cylindrical sectored-ring ultrasound phased-array applicator for minimally-invasive therapeutic ultrasound. Med Phys 2023; 50:1-19. [PMID: 36413363 PMCID: PMC9870260 DOI: 10.1002/mp.16113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 11/10/2022] [Accepted: 11/10/2022] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND The size of catheter-based ultrasound devices for delivering ultrasound energy to deep-seated tumors is constrained by the access pathway which limits their therapeutic capabilities. PURPOSE To devise and investigate a deployable applicator suitable for minimally-invasive delivery of therapeutic ultrasound, consisting of a 2D cylindrical sectored-ring ultrasound phased array, integrated within an expandable paraboloid-shaped balloon-based reflector. The balloon can be collapsed for compact delivery and expanded close to the target position to mimic a larger-diameter concentric-ring sector-vortex array for enhanced dynamic control of focal depth and volume. METHODS Acoustic and biothermal simulations were employed in 3D generalized homogeneous and patient-specific heterogeneous models, for three-phased array transducers with 32, 64, and 128 elements, composed of sectored 4, 8, and 16 tubular ring transducers, respectively. The applicator performance was characterized as a function of array configuration, focal depth, phasing modes, and balloon reflector geometry. A 16-element proof-of-concept phased array applicator assembly, consisting of four tubular transducers each divided into four sectors, was fabricated, and characterized with hydrophone measurements along and across the axis, and ablations in ex vivo tissue. RESULTS Simulation results indicated that transducer arrays (1.5 MHz, 9 mm OD × 20 mm long), balloon sizes (41-50 mm expanded diameter, 20-60 mm focal depth), phasing mode (0-4) and sonication duration (30 s) can produce spatially localized acoustic intensity focal patterns (focal length: 3-22 mm, focal width: 0.7-8.7 mm) and ablative thermal lesions (width: 2.7-16 mm, length: 6-46 mm) in pancreatic tissue across a 10-90 mm focal depth range. Patient-specific studies indicated that 0.1, 0.46, and 1.2 cm3 volume of tumor can be ablated in the body of the pancreas for 120 s sonications using a single axial focus (Mode 0), or four, and eight simultaneous foci in a toroidal pattern (Mode 2 and 4, respectively). Hydrophone measurements demonstrated good agreement with simulation. Experiments in which chicken meat was thermally ablated indicated that volumetric ablation can be produced using single or multiple foci. CONCLUSIONS The results of this study demonstrated the feasibility of a novel compact ultrasound applicator design capable of focusing, deep penetration, electronic steering, and volumetric thermal ablation. The proposed applicator can be used for compact endoluminal or laparoscopic delivery of localized ultrasound energy to deep-seated targets.
Collapse
Affiliation(s)
- Muhammad Zubair
- Department of Radiation Oncology University of California San Francisco USA
| | - Matthew S. Adams
- Department of Radiation Oncology University of California San Francisco USA
| | - Chris J. Diederich
- Department of Radiation Oncology University of California San Francisco USA
| |
Collapse
|
8
|
Dutta G, Manickam S, Sugumaran A. Stimuli-Responsive Hybrid Metal Nanocomposite - A Promising Technology for Effective Anticancer Therapy. Int J Pharm 2022; 624:121966. [PMID: 35764265 DOI: 10.1016/j.ijpharm.2022.121966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 06/21/2022] [Accepted: 06/23/2022] [Indexed: 11/19/2022]
Abstract
Cancer is one of the most challenging, life-threatening illnesses to cure, with over 10 million new cases diagnosed each year globally. Improved diagnostic cum treatment with common side-effects are warranting for successful therapy. Nanomaterials are recognized to improve early diagnosis, imaging, and treatment. Recently, multifunctional nanocomposites attracted considerable interest due to their low-cost production, and ideal thermal and chemical stability, and will be beneficial in future diagnostics and customized treatment capacity. Stimuli-Responsive Hybrid Metal Nanocomposites (SRHMNs) based nanocomposite materials pose the on/off delivery of bioactive compounds such as medications, genes, RNA, and DNA to specific tissue or organs and reduce toxicity. They simultaneously serve as sophisticated imaging and diagnostic tools when certain stimuli (e.g., temperature, pH, redox, ultrasound, or enzymes) activate the nanocomposite, resulting in the imaging-guided transport of the payload at defined sites. This review in detail addresses the recent advancements in the design and mechanism of internal breakdown processes of the functional moiety from stimuli-responsive systems in response to a range of stimuli coupled with metal nanoparticles. Also, it provides a thorough understanding of SRHMNs, enabling non-invasive interventional therapy by resolving several difficulties in cancer theranostics.
Collapse
Affiliation(s)
- Gouranga Dutta
- Department of Pharmaceutics, SRM College of Pharmacy, SRM Institute of Science and Technology, Kattankulathur 603203, India
| | - Sivakumar Manickam
- Petroleum and Chemical Engineering, Faculty of Engineering, Universiti Teknologi Brunei, Jalan Tungku Link Gadong, BE1410, Brunei Darussalam
| | - Abimanyu Sugumaran
- Department of Pharmaceutics, SRM College of Pharmacy, SRM Institute of Science and Technology, Kattankulathur 603203, India.
| |
Collapse
|
9
|
Tynan A, Brines M, Chavan SS. Control of inflammation using non-invasive neuromodulation: past, present and promise. Int Immunol 2022; 34:119-128. [PMID: 34558623 PMCID: PMC8783606 DOI: 10.1093/intimm/dxab073] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Accepted: 09/20/2021] [Indexed: 12/14/2022] Open
Abstract
The nervous system has been increasingly recognized as a novel and accessible target in the regulation of inflammation. The use of implantable and invasive devices targeting neural circuits has yielded successful results in clinical settings but does have some risk or adverse effects. Recent advances in technology and understanding of mechanistic pathways have opened new avenues of non-invasive neuromodulation. Through this review we discuss the novel research and outcomes of major modalities of non-invasive neuromodulation in the context of inflammation including transcutaneous electrical, magnetic and ultrasound neuromodulation. In addition to highlighting the scientific observations and breakthroughs, we discuss the underlying mechanisms and pathways for neural regulation of inflammation.
Collapse
Affiliation(s)
- Aisling Tynan
- Laboratory of Biomedical Science, Institute of Bioelectronic Medicine, Feinstein Institutes for Medical Research, Northwell Health, 350 Community Drive, Manhasset, NY, USA
| | - Michael Brines
- Laboratory of Biomedical Science, Institute of Bioelectronic Medicine, Feinstein Institutes for Medical Research, Northwell Health, 350 Community Drive, Manhasset, NY, USA
| | - Sangeeta S Chavan
- Laboratory of Biomedical Science, Institute of Bioelectronic Medicine, Feinstein Institutes for Medical Research, Northwell Health, 350 Community Drive, Manhasset, NY, USA
- Elmezzi Graduate School of Molecular Medicine, 350 Community Drive, Manhasset, NY, USA
- Donald and Barbara Zucker School of Medicine at Hofstra University, Hempstead, NY, USA
| |
Collapse
|
10
|
Do MT, Ly TH, Choi MJ, Cho SY. Clinical application of the therapeutic ultrasound in urologic disease: Part II of the therapeutic ultrasound in urology. Investig Clin Urol 2022; 63:394-406. [PMID: 35670002 PMCID: PMC9262482 DOI: 10.4111/icu.20220060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Revised: 03/14/2022] [Accepted: 03/17/2022] [Indexed: 11/18/2022] Open
Abstract
This article aimed to review the clinical application and evidence of the therapeutic ultrasound in detail for urological diseases such as prostate cancer, kidney tumor, erectile dysfunction, and urolithiasis. We searched for articles about high-intensity focused ultrasound (HIFU), extracorporeal shock wave therapy, ultrasound lithotripsy, and extracorporeal shockwave lithotripsy (ESWL) in the MEDLINE and Embase. HIFU may be indicated as a primary treatment for low- or intermediate-risk prostate cancer, and salvage therapy for local recurrence as a promising way to address the limitations of current standard therapies. The application of HIFU in treating kidney tumors has scarcely been reported with unsatisfactory results. Evidence indicates that low-intensity shockwave therapy improves subjective and objective erectile function in patients with erectile dysfunction. Regarding the application of ultrasound in stone management, the novel combination of ultrasound lithotripsy and other energy sources in a single probe promises to be a game-changer in efficiently disintegrating large kidney stones in percutaneous nephrolithotomy. ESWL is losing its role in managing upper urinary tract calculi worldwide. The burst-wave lithotripsy and ultrasound propulsion could be the new hope to regain its position in the lithotripsy field. According to our investigations and reviews, cavitation bubbles of the therapeutic ultrasound are actively being used in the field of urology. Although clinical evidence has been accumulated in urological diseases such as prostate cancer, kidney tumor, erectile dysfunction, and lithotripsy, further development is needed to be a game-changer in treating these diseases.
Collapse
Affiliation(s)
- Minh-Tung Do
- Department of Surgery, Hai Phong University of Medicine and Pharmacy, Hai Phong, Viet Nam
- Department of Urology, Seoul National University College of Medicine, Seoul, Korea
| | - Tam Hoai Ly
- Department of Urology, Cho Ray Hospital, Ho Chi Minh City, Viet Nam
| | - Min Joo Choi
- Department of Medicine, Jeju National University College of Medicine, Jeju, Korea
| | - Sung Yong Cho
- Department of Urology, Seoul National University College of Medicine, Seoul, Korea
- Department of Urology, Seoul National University Hospital, Seoul, Korea
| |
Collapse
|
11
|
A Review of High-Intensity Focused Ultrasound in Urology. Cancers (Basel) 2021; 13:cancers13225696. [PMID: 34830852 PMCID: PMC8616438 DOI: 10.3390/cancers13225696] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 11/08/2021] [Accepted: 11/10/2021] [Indexed: 01/20/2023] Open
Abstract
This review provides an introduction to high-intensity focused ultrasound (HIFU) and reviews its historical and current use in urological surgery. Current and historical literature (1927-2020), including that describing trials and review articles in the medical and ultrasonic literature, has been reviewed, using Pub Med and Cochrane search engines. HIFU is currently one of a number of treatments for prostate cancer, both as a primary treatment that can be repeated, and as a salvage treatment post-radiotherapy. HIFU is not yet sufficiently mature to be a standard treatment for renal cancer or other urological diseases, although there has been some success in early clinical trials. As the technology improves, this situation is likely to change. HIFU has been understood as a concept for a century, and has been applied in experimental use for half that time. It is now an accepted treatment with low morbidity in many diseases outside the scope of this review. In urological surgery, prostate HIFU is accepted as a localised treatment in selected cases, with potentially fewer side effects than other localised therapies. Currently the treatment for renal cancer is hindered by the perinephric fat and the position of the kidneys behind the ribs; however, as the technology improves with image fusion, faster treatments, and the ability with phased array transducers and motion compensation to overcome the problems caused by the ribs and breathing, successful treatment of kidney tumours will become more of a reality. In due course, there will be a new generation of machines for treating prostate cancer. These devices will further minimise the side effects of radical treatment of prostate cancer.
Collapse
|
12
|
Neutrophil-mediated clinical nanodrug for treatment of residual tumor after focused ultrasound ablation. J Nanobiotechnology 2021; 19:345. [PMID: 34715854 PMCID: PMC8555249 DOI: 10.1186/s12951-021-01087-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Accepted: 10/13/2021] [Indexed: 02/08/2023] Open
Abstract
Background The risk of local recurrence after high-intensity focused ultrasound (HIFU) is relatively high, resulting in poor prognosis of malignant tumors. The combination of HIFU with traditional chemotherapy continues to have an unsatisfactory outcome because of off-site drug uptake. Results Herein, we propose a strategy of inflammation-tendency neutrophil-mediated clinical nanodrug targeted therapy for residual tumors after HIFU ablation. We selected neutrophils as carriers and PEGylated liposome doxorubicin (PLD) as a model chemotherapeutic nanodrug to form an innovative cell therapy drug (PLD@NEs). The produced PLD@NEs had a loading capacity of approximately 5 µg of PLD per 106 cells and maintained the natural characteristics of neutrophils. The targeting performance and therapeutic potential of PLD@NEs were evaluated using Hepa1-6 cells and a corresponding tumor-bearing mouse model. After HIFU ablation, PLD@NEs were recruited to the tumor site by inflammation (most in 4 h) and released PLD with inflammatory stimuli, leading to targeted and localized postoperative chemotherapy. Conclusions This effective integrated method fully leverages the advantages of HIFU, chemotherapy and neutrophils to attract more focus on the practice of improving existing clinical therapies. Graphical Abstract ![]()
Supplementary Information The online version contains supplementary material available at 10.1186/s12951-021-01087-w.
Collapse
|
13
|
Stocker GE, Zhang M, Xu Z, Hall TL. Endocavity Histotripsy for Efficient Tissue Ablation-Transducer Design and Characterization. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2896-2905. [PMID: 33507869 PMCID: PMC8451243 DOI: 10.1109/tuffc.2021.3055138] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
A 34-mm aperture transducer was designed and tested for proof of concept to ablate tissues using an endocavity histotripsy device. Several materials and two drivers were modeled and tested to determine an effective piezoelectric-matching layer combination and driver design. The resulting transducer was fabricated using 1.5 MHz porous PZT and PerFORM 3-D printed acoustic lenses and was driven with a multicycle class-D amplifier. The lower frequency, compared to previously developed small form factor histotripsy transducers, was selected to allow for more efficient volume ablation of tissue. The transducer was characterized and tested by measuring pressure field maps in the axial and lateral planes and pressure output as a function of driving voltage. The axial and lateral full-width-half-maximums of the focus were found to be 6.1 and 1.1 mm, respectively. The transducer was estimated to generate 34.5-MPa peak negative focal pressure with a peak-to-peak driving voltage of 1345 V. Performance testing was done by ablating volumes of bovine liver tissues ( n = 3 ). The transducer was found to be capable of ablating tissues at its full working distance of 17 mm.
Collapse
|
14
|
Liu DD, Ullah M, Concepcion W, Dahl JJ, Thakor AS. The role of ultrasound in enhancing mesenchymal stromal cell-based therapies. Stem Cells Transl Med 2020; 9:850-866. [PMID: 32157802 PMCID: PMC7381806 DOI: 10.1002/sctm.19-0391] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2019] [Accepted: 02/17/2020] [Indexed: 12/18/2022] Open
Abstract
Mesenchymal stromal cells (MSCs) have been a popular platform for cell‐based therapy in regenerative medicine due to their propensity to home to damaged tissue and act as a repository of regenerative molecules that can promote tissue repair and exert immunomodulatory effects. Accordingly, a great deal of research has gone into optimizing MSC homing and increasing their secretion of therapeutic molecules. A variety of methods have been used to these ends, but one emerging technique gaining significant interest is the use of ultrasound. Sound waves exert mechanical pressure on cells, activating mechano‐transduction pathways and altering gene expression. Ultrasound has been applied both to cultured MSCs to modulate self‐renewal and differentiation, and to tissues‐of‐interest to make them a more attractive target for MSC homing. Here, we review the various applications of ultrasound to MSC‐based therapies, including low‐intensity pulsed ultrasound, pulsed focused ultrasound, and extracorporeal shockwave therapy, as well as the use of adjunctive therapies such as microbubbles. At a molecular level, it seems that ultrasound transiently generates a local gradient of cytokines, growth factors, and adhesion molecules that facilitate MSC homing. However, the molecular mechanisms underlying these methods are far from fully elucidated and may differ depending on the ultrasound parameters. We thus put forth minimal criteria for ultrasound parameter reporting, in order to ensure reproducibility of studies in the field. A deeper understanding of these mechanisms will enhance our ability to optimize this promising therapy to assist MSC‐based approaches in regenerative medicine.
Collapse
Affiliation(s)
- Daniel D Liu
- Interventional Regenerative Medicine and Imaging Laboratory, Department of Radiology, Stanford University, Palo Alto, California
| | - Mujib Ullah
- Interventional Regenerative Medicine and Imaging Laboratory, Department of Radiology, Stanford University, Palo Alto, California
| | - Waldo Concepcion
- Department of Surgery, Stanford University, Palo Alto, California
| | - Jeremy J Dahl
- Interventional Regenerative Medicine and Imaging Laboratory, Department of Radiology, Stanford University, Palo Alto, California
| | - Avnesh S Thakor
- Interventional Regenerative Medicine and Imaging Laboratory, Department of Radiology, Stanford University, Palo Alto, California
| |
Collapse
|
15
|
Izadifar Z, Izadifar Z, Chapman D, Babyn P. An Introduction to High Intensity Focused Ultrasound: Systematic Review on Principles, Devices, and Clinical Applications. J Clin Med 2020; 9:jcm9020460. [PMID: 32046072 PMCID: PMC7073974 DOI: 10.3390/jcm9020460] [Citation(s) in RCA: 164] [Impact Index Per Article: 41.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2020] [Revised: 01/29/2020] [Accepted: 02/01/2020] [Indexed: 12/22/2022] Open
Abstract
Ultrasound can penetrate deep into tissues and interact with human tissue via thermal and mechanical mechanisms. The ability to focus an ultrasound beam and its energy onto millimeter-size targets was a significant milestone in the development of therapeutic applications of focused ultrasound. Focused ultrasound can be used as a non-invasive thermal ablation technique for tumor treatment and is being developed as an option to standard oncologic therapies. High-intensity focused ultrasound has now been used for clinical treatment of a variety of solid malignant tumors, including those in the pancreas, liver, kidney, bone, prostate, and breast, as well as uterine fibroids and soft-tissue sarcomas. Magnetic resonance imaging and Ultrasound imaging can be combined with high intensity focused ultrasound to provide real-time imaging during ablation. Magnetic resonance guided focused ultrasound represents a novel non-invasive method of treatment that may play an important role as an alternative to open neurosurgical procedures for treatment of a number of brain disorders. This paper briefly reviews the underlying principles of HIFU and presents current applications, outcomes, and complications after treatment. Recent applications of Focused ultrasound for tumor treatment, drug delivery, vessel occlusion, histotripsy, movement disorders, and vascular, oncologic, and psychiatric applications are reviewed, along with clinical challenges and potential future clinical applications of HIFU.
Collapse
Affiliation(s)
- Zahra Izadifar
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
- Correspondence: ; Tel.: +1-306-966-7827; Fax: +1-306-966-4651
| | - Zohreh Izadifar
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
| | - Dean Chapman
- Anatomy & Cell Biology, University of Saskatchewan, Saskatoon, SK S7N 5E5, Canada
| | - Paul Babyn
- Department of Medical Imaging, Royal University Hospital, Saskatoon, SK S7N 0W8, Canada
| |
Collapse
|
16
|
Kim H, Wu H, Cho N, Zhong P, Mahmood K, Lyerly HK, Jiang X. Miniaturized Intracavitary Forward-Looking Ultrasound Transducer for Tissue Ablation. IEEE Trans Biomed Eng 2019; 67:2084-2093. [PMID: 31765299 DOI: 10.1109/tbme.2019.2954524] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
OBJECTIVE This paper aims to develop a miniaturized forward-looking ultrasound transducer for intracavitary tissue ablation, which can be used through an endoscopic device. The internal ultrasound (US) delivery is capable of directly interacting with the target tumor, resolving adverse issues of currently available US devices, such as unintended tissue damage and insufficient delivery of acoustic power. METHODS To transmit a high acoustic pressure from a small aperture (<3 mm), a double layer transducer (1.3 MHz) was designed and fabricated based on numerical simulations. The electric impedance and the acoustic pressure of the actual device was characterized with an impedance analyzer and a hydrophone. Ex vivo tissue ablation tests and temperature monitoring were then conducted with porcine livers. RESULTS The acoustic intensity of the transducer was 37.1 W/cm2 under 250 Vpp and 20% duty cycle. The tissue temperature was elevated to 51.8 °C with a 67 Hz pulse-repetition frequency. The temperature profile in the tissue indicated that ultrasound energy was effectively absorbed inside the tissue. During a 5-min sonification, an approximate tissue volume of 2.5 × 2.5 × 1.0 mm3 was ablated, resulting in an irreversible lesion. CONCLUSION This miniaturized US transducer is a promising medical option for the precise tissue ablation, which can reduce the risk of unintended tissue damage found in noninvasive US treatments. SIGNIFICANCE Having a small aperture (2 mm), the intracavitary device is capable of ablating a bio tissue in 5 min with a relatively low electric power (<17 W).
Collapse
|
17
|
Adams MS, Diederich CJ. Deployable cylindrical phased-array applicator mimicking a concentric-ring configuration for minimally-invasive delivery of therapeutic ultrasound. Phys Med Biol 2019; 64:125001. [PMID: 31108478 DOI: 10.1088/1361-6560/ab2318] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
A novel design for a deployable catheter-based ultrasound applicator for endoluminal and laparoscopic intervention is introduced. By combining a 1D cylindrical ring phased array with an expandable paraboloid or conical-shaped balloon-based reflector, the applicator can be controllably collapsed for compact delivery and deployed to mimic a forward-firing larger diameter concentric ring array with tight focusing and electronic steering capabilities in depth. Comprehensive acoustic and biothermal parametric studies were employed to characterize the capabilities of the applicator design as a function of transducer dimensions, phased array configuration, and balloon reflector geometry. Modeling results indicate that practical balloon sizes (43-57 mm expanded diameter), transducer array configurations (e.g. 1.5 MHz, 10 mm OD × 20 mm length, 8 or 16 array elements), and sonication durations (30 s) are capable of producing spatially-localized acoustic intensity focal patterns and ablative thermal lesions (width: 2.8-4.8 mm; length: 5.3-40.1 mm) in generalized soft tissue across a 5-100 mm depth range. Larger focal intensity gain magnitudes and narrower focal dimensions are attainable using paraboloid-shaped balloon reflectors with natural geometric focal depths of 25-55 mm, whereas conical-shaped reflectors (angled 45-55°) produce broader foci and extend electronic steering range in depth. A proof-of-concept phased array applicator assembly was fabricated and characterized using hydrophone and radiation force balance measurements and demonstrated good agreement with simulation. The results of this study suggest that combining small diameter cylindrical phased arrays with expandable balloon reflectors can enhance minimally invasive ultrasound-based intervention by augmenting achievable focal gains and penetration depths with dynamic adjustment of treatment depth.
Collapse
|
18
|
Schostak M, Wendler JJ, Baumunk D, Blana A, Ganzer R, Franiel T, Hadaschik B, Henkel T, Köhrmann KU, Köllermann J, Kuru T, Machtens S, Roosen A, Salomon G, Schlemmer HP, Sentker L, Witzsch U, Liehr UB. Treatment of Small Renal Masses. Urol Oncol 2019. [DOI: 10.1007/978-3-319-42623-5_61] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
19
|
Sengupta S, Balla VK. A review on the use of magnetic fields and ultrasound for non-invasive cancer treatment. J Adv Res 2018; 14:97-111. [PMID: 30109147 PMCID: PMC6090088 DOI: 10.1016/j.jare.2018.06.003] [Citation(s) in RCA: 78] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Revised: 06/19/2018] [Accepted: 06/19/2018] [Indexed: 12/23/2022] Open
Abstract
Current popular cancer treatment options, include tumor surgery, chemotherapy, and hormonal treatment. These treatments are often associated with some inherent limitations. For instances, tumor surgery is not effective in mitigating metastases; the anticancer drugs used for chemotherapy can quickly spread throughout the body and is ineffective in killing metastatic cancer cells. Therefore, several drug delivery systems (DDS) have been developed to target tumor cells, and release active biomolecule at specific site to eliminate the side effects of anticancer drugs. However, common challenges of DDS used for cancer treatment, include poor site-specific accumulation, difficulties in entering the tumor microenvironment, poor metastases and treatment efficiency. In this context, non-invasive cancer treatment approaches, with or without DDS, involving the use of light, heat, magnetic field, electrical field and ultrasound appears to be very attractive. These approaches can potentially improve treatment efficiency, reduce recovery time, eliminate infections and scar formation. In this review we focus on the effects of magnetic fields and ultrasound on cancer cells and their application for cancer treatment in the presence of drugs or DDS.
Collapse
Affiliation(s)
- Somoshree Sengupta
- Bioceramics and Coating Division, CSIR-Central Glass and Ceramic Research Institute, 196 Raja S.C. Mullick Road, Kolkata 700032, India
- Academy of Scientific and Innovative Research (AcSIR), CSIR-Central Glass and Ceramic Research Institute Campus, 196 Raja S.C. Mullick Road, Kolkata 700032, India
| | - Vamsi K. Balla
- Bioceramics and Coating Division, CSIR-Central Glass and Ceramic Research Institute, 196 Raja S.C. Mullick Road, Kolkata 700032, India
- Academy of Scientific and Innovative Research (AcSIR), CSIR-Central Glass and Ceramic Research Institute Campus, 196 Raja S.C. Mullick Road, Kolkata 700032, India
| |
Collapse
|
20
|
Ischemia Techniques in Nephron-sparing Surgery: A Systematic Review and Meta-Analysis of Surgical, Oncological, and Functional Outcomes. Eur Urol 2018; 75:477-491. [PMID: 30327272 DOI: 10.1016/j.eururo.2018.10.005] [Citation(s) in RCA: 52] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Accepted: 10/01/2018] [Indexed: 01/20/2023]
Abstract
CONTEXT The optimal ischemia technique at partial nephrectomy (PN) for renal masses is yet to be determined. OBJECTIVE To summarize and analyze the current evidence about surgical, oncological, and functional outcomes after different ischemia techniques (cold, warm, and zero ischemia) at PN. EVIDENCE ACQUISITION A computerized systematic literature search was performed by using PubMed (MEDLINE) and Science Direct. Identification and selection of the studies were conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) criteria. Outcomes of interest were estimated blood loss (EBL), overall complications, positive surgical margins, local tumor recurrence, and renal function preservation. Meta-analysis and forest-plot diagrams were performed. Overall pooled estimates, together with 95% confidence intervals (CIs), of the incidence of all parameters were obtained using a random effect model (RE-Model) on the log transformed means (MLN), proportion, or standardized mean change, as deemed appropriate. EVIDENCE SYNTHESIS One hundred and fifty-six studies were included. No clinically meaningful differences were found in terms of EBL after cold (mean: 215.5; 95% CI: 154.2-276.8m), warm (mean: 201.8; 95% CI: 175.0-228.7ml), or zero (mean: 261.2; 95% CI: 171.0-351.3ml) ischemia technique. Overall, postoperative complications were recorded in 14.1% (95% CI: 6.7-27.4), 11.1% (95% CI: 10.0-12.3), and 9.7% (95% CI: 7.7-12.2) of patients after cold, warm, and zero ischemia (p<0.01), respectively. Positive surgical margins were recorded in 4.8% (95% CI: 1.9-10.9), 4.0% (95% CI: 3.4-4.8), and 5.6% (95% CI: 3.1-9.8) of patients after cold, warm, and zero ischemia (p<0.01), respectively. Local recurrence was recorded in 3.2% (95% CI: 1.9-5.2) and 3.1% (95% CI: 0.7-11.5) of patients after warm and zero ischemia (p<0.01), respectively. The log2 of estimated glomerular filtration ratio mean changes were-1.37 (95% CI:-3.42 to 0.68),-1.00 (-2.04 to 0.03), and-0.71 (-1.15 to-0.27) ml/min after cold, warm, and zero ischemia, respectively. Low level of evidence, retrospective nature of most of included studies, a high risk of selection bias, and heterogeneity within included studies limited the overall quality of the analysis. CONCLUSIONS The effect of ischemia technique at PN is still debatable and subject to confounding by several factors, namely, patients' selection criteria, surgical technique used, and percentage of functional parenchyma spared during surgery. These confounders bias available evidence and were addressed by only a small part of available studies. Unfortunately, the overall quality of literature evidences and the high risk of selection bias limit the possibility of any causal interpretation about the relationship between the ischemia technique used and surgical, oncological, or functional outcomes. Thus, none of the available ischemia technique could be recommended over the other. PATIENT SUMMARY The present analysis shows that none of the available ischemia techniques, namely, cold, warm, or zero ischemia, is universally superior to the others, and other factors play a role in the surgical outcome.
Collapse
|
21
|
Abstract
Over the past few decades, applications of ultrasound (US) in drug delivery have been documented widely for local and site-specific release of bioactives in a controlled manner, after acceptable use in mild physical therapy for tendinitis and bursitis, and for high-energy applications in fibroid ablation, cataract removal, bone fracture healing, etc. US is a non-invasive, efficient, targetable and controllable technique. Drug delivery can be enhanced by applying directed US in terms of targeting and intracellular uptake. US cannot only provide local hyperthermia but can also enhance local extravasations and permeability of the cell membrane for delivery of cell-impermeable and poorly permeable drugs. It is also found to increase the anticancer efficacy of drug against solid tumors by facilitating uniform drug delivery throughout the tumor mass. This review summarizes the mechanism of US; various drug delivery systems like microbubbles, liposomes, and micelles; and biological manifestations employed for improving treatment of cancer, i.e., hyperthermia and enhanced extravasation. Safety issues are also discussed for better therapeutic outcomes of US-assisted drug delivery to tumors. This review can be a beneficial asset to the scientists looking at non-invasive techniques (externally guided) for improving the anticancer potential of drug delivery systems.
Collapse
Affiliation(s)
- Ankit Jain
- Institute of Pharmaceutical Research, GLA University, NH-2, Mathura-Delhi Road, Mathura, UP, 281 406, India
| | - Ankita Tiwari
- Pharmaceutics Research Projects Laboratory, Department of Pharmaceutical Sciences, Dr. Hari Singh Gour Central University, Sagar, MP, 470 003, India
| | - Amit Verma
- Pharmaceutics Research Projects Laboratory, Department of Pharmaceutical Sciences, Dr. Hari Singh Gour Central University, Sagar, MP, 470 003, India
| | - Sanjay K Jain
- Pharmaceutics Research Projects Laboratory, Department of Pharmaceutical Sciences, Dr. Hari Singh Gour Central University, Sagar, MP, 470 003, India.
| |
Collapse
|
22
|
Schostak M, Wendler JJ, Baumunk D, Blana A, Ganzer R, Franiel T, Hadaschik B, Henkel T, Köhrmann KU, Köllermann J, Kuru T, Machtens S, Roosen A, Salomon G, Schlemmer HP, Sentker L, Witzsch U, Liehr UB. Treatment of Small Renal Masses. Urol Oncol 2018. [DOI: 10.1007/978-3-319-42603-7_61-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
23
|
Abbass MA, Killin JK, Mahalingam N, Hooi FM, Barthe PG, Mast TD. Real-Time Spatiotemporal Control of High-Intensity Focused Ultrasound Thermal Ablation Using Echo Decorrelation Imaging in ex Vivo Bovine Liver. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:199-213. [PMID: 29074273 PMCID: PMC5712268 DOI: 10.1016/j.ultrasmedbio.2017.09.007] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2017] [Revised: 08/28/2017] [Accepted: 09/07/2017] [Indexed: 05/05/2023]
Abstract
The ability to control high-intensity focused ultrasound (HIFU) thermal ablation using echo decorrelation imaging feedback was evaluated in ex vivo bovine liver. Sonications were automatically ceased when the minimum cumulative echo decorrelation within the region of interest exceeded an ablation control threshold, determined from preliminary experiments as -2.7 (log-scaled decorrelation per millisecond), corresponding to 90% specificity for local ablation prediction. Controlled HIFU thermal ablation experiments were compared with uncontrolled experiments employing two, five or nine sonication cycles. Means and standard errors of the lesion width, area and depth, as well as receiver operating characteristic curves testing ablation prediction performance, were computed for each group. Controlled trials exhibited significantly smaller average lesion area, width and treatment time than five-cycle or nine-cycle uncontrolled trials and also had significantly greater prediction capability than two-cycle uncontrolled trials. These results suggest echo decorrelation imaging is an effective approach to real-time HIFU ablation control.
Collapse
Affiliation(s)
- Mohamed A Abbass
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | - Jakob K Killin
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | | | - Fong Ming Hooi
- Ultrasound Division, Siemens Healthcare, Issaquah, Washington, USA
| | | | - T Douglas Mast
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA.
| |
Collapse
|
24
|
Adams MS, Salgaonkar VA, Scott SJ, Sommer G, Diederich CJ. Integration of deployable fluid lenses and reflectors with endoluminal therapeutic ultrasound applicators: Preliminary investigations of enhanced penetration depth and focal gain. Med Phys 2017; 44:5339-5356. [PMID: 28681404 DOI: 10.1002/mp.12458] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Revised: 06/19/2017] [Accepted: 07/02/2017] [Indexed: 02/06/2023] Open
Abstract
PURPOSE Catheter-based ultrasound applicators can generate thermal ablation of tissues adjacent to body lumens, but have limited focusing and penetration capabilities due to the small profile of integrated transducers required for the applicator to traverse anatomical passages. This study investigates a design for an endoluminal or laparoscopic ultrasound applicator with deployable acoustic reflector and fluid lens components, which can be expanded after device delivery to increase the effective acoustic aperture and allow for deeper and dynamically adjustable target depths. Acoustic and biothermal theoretical studies, along with benchtop proof-of-concept measurements, were performed to investigate the proposed design. METHODS The design schema consists of an array of tubular transducer(s) situated at the end of a catheter assembly, surrounded by an expandable water-filled conical balloon with a secondary reflective compartment that redirects acoustic energy distally through a plano-convex fluid lens. By controlling the lens fluid volume, the convex surface can be altered to adjust the focal length or collapsed for device insertion or removal. Acoustic output of the expanded applicator assembly was modeled using the rectangular radiator method and secondary sources, accounting for reflection and refraction at interfaces. Parametric studies of transducer radius (1-5 mm), height (3-25 mm), frequency (1.5-3 MHz), expanded balloon diameter (10-50 mm), lens focal length (10-100 mm), lens fluid (silicone oil, perfluorocarbon), and tissue attenuation (0-10 Np/m/MHz) on beam distributions and focal gain were performed. A proof-of-concept applicator assembly was fabricated and characterized using hydrophone-based intensity profile measurements. Biothermal simulations of endoluminal ablation in liver and pancreatic tissue were performed for target depths between 2 and 10 cm. RESULTS Simulations indicate that focal gain and penetration depth scale with the expanded reflector-lens balloon diameter, with greater achievable performance using perfluorocarbon lens fluid. Simulations of a 50 mm balloon OD, 10 mm transducer outer diameter (OD), 1.5 MHz assembly in water resulted in maximum intensity gain of ~170 (focal dimensions: ~12 mm length × 1.4 mm width) at ~5 cm focal depth and focal gains above 100 between 24 and 84 mm depths. A smaller (10 mm balloon OD, 4 mm transducer OD, 1.5 MHz) configuration produced a maximum gain of 6 at 9 mm depth. Compared to a conventional applicator with a fixed spherically focused transducer of 12 mm diameter, focal gain was enhanced at depths beyond 20 mm for assembly configurations with balloon diameters ≥ 20 mm. Hydrophone characterizations of the experimental assembly (31 mm reflector/lens diameter, 4.75 mm transducer radius, 1.7 MHz) illustrated focusing at variable depths between 10-70 mm with a maximum gain of ~60 and demonstrated agreement with theoretical simulations. Biothermal simulations (30 s sonication, 75 °C maximum) indicate that investigated applicator assembly configurations, at 30 mm and 50 mm balloon diameters, could create localized ellipsoidal thermal lesions increasing in size from 10 to 55 mm length × 3-6 mm width in liver tissue as target depth increased from 2 to 10 cm. CONCLUSIONS Preliminary theoretical and experimental analysis demonstrates that combining endoluminal ultrasound with an expandable acoustic reflector and fluid lens assembly can significantly enhance acoustic focal gain and penetration from inherently smaller diameter catheter-based applicators.
Collapse
Affiliation(s)
- Matthew S Adams
- Thermal Therapy Research Group, University of California San Francisco, 2340 Sutter Street, S341, San Francisco, CA, 94115, USA.,University of California, Berkeley - University of California, San Francisco Graduate Program in Bioengineering, University of California, CA, USA
| | - Vasant A Salgaonkar
- Thermal Therapy Research Group, University of California San Francisco, 2340 Sutter Street, S341, San Francisco, CA, 94115, USA
| | - Serena J Scott
- Thermal Therapy Research Group, University of California San Francisco, 2340 Sutter Street, S341, San Francisco, CA, 94115, USA
| | - Graham Sommer
- Department of Radiology, Stanford University, Stanford, CA, 94305, USA
| | - Chris J Diederich
- Thermal Therapy Research Group, University of California San Francisco, 2340 Sutter Street, S341, San Francisco, CA, 94115, USA.,University of California, Berkeley - University of California, San Francisco Graduate Program in Bioengineering, University of California, CA, USA
| |
Collapse
|
25
|
Abstract
BACKGROUND The rising incidence of renal cell carcinoma, its more frequent early detection (stage T1a) and the increasing prevalence of chronic renal failure with higher morbidity and shorter life expectancy underscore the need for multimodal focal nephron-sparing therapy. DISCUSSION During the past decade, the gold standard shifted from radical to partial nephrectomy. Depending on the surgeon's experience, the patient's constitution and the tumor's location, the intervention can be performed laparoscopically with the corresponding advantages of lower invasiveness. A treatment alternative can be advantageous for selected patients with high morbidity and/or an increased risk of complications associated with anesthesia or surgery. Corresponding risk stratification necessitates previous confirmation of the small renal mass (cT1a) by histological examination of biopsy samples. Active surveillance represents a controlled delay in the initiation of treatment. RESULTS Percutaneous radiofrequency ablation (RFA) and laparoscopic cryoablation are currently the most common treatment alternatives, although there are limitations particularly for renal tumors located centrally near the hilum. More recent ablation procedures such as high intensity focused ultrasound (HIFU), irreversible electroporation, microwave ablation, percutaneous stereotactic ablative radiotherapy and high-dose brachytherapy have high potential in some cases but are currently regarded as experimental for the treatment of renal cell carcinoma.
Collapse
|
26
|
van Breugel JMM, de Greef M, Wijlemans JW, Schubert G, van den Bosch MAAJ, Moonen CTW, Ries MG. Thermal ablation of a confluent lesion in the porcine kidney with a clinically available MR-HIFU system. Phys Med Biol 2017; 62:5312-5326. [PMID: 28557798 DOI: 10.1088/1361-6560/aa75b3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The incidence of small renal masses (SRMs) sized <4 cm has increased over the decades (as co-findings/or due to introduction of cross sectional imaging). Currently, partial nephrectomy (PN) or watchful waiting is advised in these patients. Ultimately, 80-90% of these SRMs require surgical treatment and PN is associated with a 15% complication rate. In this aging population, with possible comorbidities and poor health condition, both PN and watchful waiting are non-ideal treatment options. This resulted in an increased need for early, non-invasive treatment strategies such as MR-guided high intensity focused ultrasound (MR-HIFU). (i) To investigate the feasibility of creating a confluent lesion in the kidney using respiratory-gated MR-HIFU under clinical conditions in a pre-clinical study and (ii) to evaluate the reproducibility of the MR-HIFU ablation strategy. Healthy pigs (n = 10) under general anesthesia were positioned on a clinical MR-HIFU system with integrated cooling. A honeycomb pattern of seven overlapping ablation cells (4 × 4 × 10 mm3, 450 W, <30 s) was ablated successively in the cortex of the porcine kidney. Both MR thermometry and acoustic energy delivery were respiratory gated using a pencil beam navigator on the contralateral kidney. The non-perfused volume (NPV) was visualized after the last sonication by contrast-enhanced (CE) T 1-weighted MR (T 1 w) imaging. Cell viability staining was performed to visualize the extent of necrosis. RESULTS a median NPV of 0.62 ml was observed on CE-T 1 w images (IQR 0.58-1.57 ml, range 0.33-2.75 ml). Cell viability staining showed a median damaged volume of 0.59 ml (IQR 0.24-1.35 ml, range 0-4.1 ml). Overlooking of the false rib, shivering of the pig, and too large depth combined with a large heat-sink effect resulted in insufficient heating in 4 cases. The NPV and necrosed volume were confluent in all cases in which an ablated volume could be observed. Our results demonstrated the feasibility of creating a confluent volume of ablated kidney cortical tissue in vivo with MR-HIFU on a clinically available system using respiratory gating and near-field cooling and showed its reproducibility.
Collapse
Affiliation(s)
- J M M van Breugel
- Center for Imaging Sciences, University Medical Center Utrecht, Utrecht, Netherlands
| | | | | | | | | | | | | |
Collapse
|
27
|
Schostak M, Wendler JJ, Baumunk D, Blana A, Ganzer R, Franiel T, Hadaschik B, Henkel T, Köhrmann KU, Köllermann J, Kuru T, Machtens S, Roosen A, Salomon G, Schlemmer HP, Sentker L, Witzsch U, Liehr UB. Treatment of Small Renal Masses. Urol Oncol 2017. [DOI: 10.1007/978-3-319-42603-7_61-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
28
|
|
29
|
de Castro Abreu AL, Ukimura O, Shoji S, Leslie S, Chopra S, Marien A, Matsugasumi T, Dharmaraja A, Wong K, Zaba N, Ma Y, Desai MM, Gill IS. Robotic transmural ablation of bladder tumors using high-intensity focused ultrasound: Experimental study. Int J Urol 2016; 23:501-8. [PMID: 27037721 DOI: 10.1111/iju.13083] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2015] [Accepted: 02/21/2016] [Indexed: 12/01/2022]
Abstract
OBJECTIVES To evaluate the feasibility of robot-assisted laparoscopic high-intensity focused ultrasound for targeted, extravesical, transmural, full-thickness ablation of intact bladder wall and tumor. METHODS In three fresh cadavers and one acute porcine model, the transperitoneal robotic approach was used to mobilize the bladder and create a midline cystotomy. "Mimic" bladder tumors (2 tumors/case) were created by robotically suturing a piece of striated muscle (2.5 × 2.5 cm) to the luminal, urothelial surface of the bladder wall. The cystotomy was suture-repaired and bladder distended with 250 mL saline. A laparoscopic high-intensity focused ultrasound probe was robotically placed extravesically in direct contact with the serosal surface of the bladder wall to image the "mimic" tumor. Targeted, transmural, full-thickness high-intensity focus ultrasound ablation of the "mimic" tumor and adjacent bladder was carried out under real-time ultrasound and robotic monitoring. Untreated areas of the bladder served as a comparison. Post-procedure, gross and microscopic examinations were carried out. RESULTS Laparoscopic high-intensity focused ultrasound ablation was feasible for all "mimic" tumors (100%). Real-time ultrasound clearly visualized the "mimic" tumor. Simultaneous display of the pre-planning and real-time treatment ultrasound images confirmed targeting precision. Mean operative room times for ultrasound localization, laparoscopic high-intensity focused ultrasound probe coupling, high-intensity focus ultrasound ablation, and total procedure were 3, 5, 6 and 60 min, respectively. On necropsy, no thermal/mechanical injuries occurred to the untreated bladder wall, adjacent organs or ureters. Gross inspection distinguished the treated from untreated areas. Histopathology confirmed sharply demarcated thermal coagulative necrosis and shrinkage effects between the treated and untreated areas. CONCLUSIONS Laparoscopic extravesical high-intensity focus ultrasound for transmural, full-thickness targeted ablation of intact bladder wall and tumor is feasible. This has implications for bladder-sparing surgery in select patients with solitary muscle-invasive bladder cancer.
Collapse
Affiliation(s)
- Andre Luis de Castro Abreu
- Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, Center for Focal and Image-guided Therapies, USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| | - Osamu Ukimura
- Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, Center for Focal and Image-guided Therapies, USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| | - Sunao Shoji
- Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, Center for Focal and Image-guided Therapies, USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| | - Scott Leslie
- Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, Center for Focal and Image-guided Therapies, USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| | - Sameer Chopra
- Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, Center for Focal and Image-guided Therapies, USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| | - Arnaud Marien
- Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, Center for Focal and Image-guided Therapies, USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| | - Toru Matsugasumi
- Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, Center for Focal and Image-guided Therapies, USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| | - Arjuna Dharmaraja
- Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, Center for Focal and Image-guided Therapies, USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| | - Kelvin Wong
- Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, Center for Focal and Image-guided Therapies, USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| | - Natalie Zaba
- Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, Center for Focal and Image-guided Therapies, USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| | - Yanling Ma
- Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, Center for Focal and Image-guided Therapies, USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| | - Mihir M Desai
- Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, Center for Focal and Image-guided Therapies, USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| | - Inderbir S Gill
- Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, Center for Focal and Image-guided Therapies, USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
30
|
Abstract
Renal cell carcinoma is a common malignancy with increasing incidence due to the incidental detection of non-symptomatic small renal masses on imaging. Management of these small tumors has evolved toward minimally invasive nephron-sparing techniques which include partial nephrectomy and image-guided ablation. Cryoablation and radiofrequency ablation are the most utilized ablation modalities with the former more suited for larger and central renal masses due to intra-procedural visualization of the ablation zone and reduced pelvicalyceal injury. In this article, we review the epidemiology and natural history of renal cell carcinoma, the role of biopsy, and the management options available-surgery, image-guided ablation, and active surveillance-with a focus on cryoablation. The clinical outcomes of the longer term maturing cryoablation data are discussed with reference to partial nephrectomy and radiofrequency ablation. Image-guided ablation has often been the management choice in patients deemed unfit for surgery; however, growing evidence from published series demonstrates image-guided ablation as a sound alternative treatment with equivalent oncological outcomes and minimal patient impact.
Collapse
Affiliation(s)
- Nirav Patel
- Department of Radiology, University Hospital Southampton, Tremona Road, Southampton, SO16 6YD, United Kingdom.
| | - Alexander J King
- Department of Radiology, University Hospital Southampton, Tremona Road, Southampton, SO16 6YD, United Kingdom
| | - David J Breen
- Department of Radiology, University Hospital Southampton, Tremona Road, Southampton, SO16 6YD, United Kingdom
| |
Collapse
|
31
|
MRI-Guided HIFU Methods for the Ablation of Liver and Renal Cancers. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2016; 880:43-63. [DOI: 10.1007/978-3-319-22536-4_3] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
32
|
Copelan A, Hartman J, Chehab M, Venkatesan AM. High-Intensity Focused Ultrasound: Current Status for Image-Guided Therapy. Semin Intervent Radiol 2015; 32:398-415. [PMID: 26622104 DOI: 10.1055/s-0035-1564793] [Citation(s) in RCA: 65] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Image-guided high-intensity focused ultrasound (HIFU) is an innovative therapeutic technology, permitting extracorporeal or endocavitary delivery of targeted thermal ablation while minimizing injury to the surrounding structures. While ultrasound-guided HIFU was the original image-guided system, MR-guided HIFU has many inherent advantages, including superior depiction of anatomic detail and superb real-time thermometry during thermoablation sessions, and it has recently demonstrated promising results in the treatment of both benign and malignant tumors. HIFU has been employed in the management of prostate cancer, hepatocellular carcinoma, uterine leiomyomas, and breast tumors, and has been associated with success in limited studies for palliative pain management in pancreatic cancer and bone tumors. Nonthermal HIFU bioeffects, including immune system modulation and targeted drug/gene therapy, are currently being explored in the preclinical realm, with an emphasis on leveraging these therapeutic effects in the care of the oncology patient. Although still in its early stages, the wide spectrum of therapeutic capabilities of HIFU offers great potential in the field of image-guided oncologic therapy.
Collapse
Affiliation(s)
- Alexander Copelan
- Department of Diagnostic Radiology, William Beaumont Hospital, Royal Oak, Michigan
| | - Jason Hartman
- Case Western Reserve University School of Medicine, Cleveland, Ohio
| | - Monzer Chehab
- Department of Diagnostic Radiology, William Beaumont Hospital, Royal Oak, Michigan
| | - Aradhana M Venkatesan
- Section of Abdominal Imaging, Department of Diagnostic Radiology, MD Anderson Cancer Center, Houston, Texas
| |
Collapse
|
33
|
Les traitements ablatifs dans le cancer du rein localisé : revue de la littérature en 2014. Prog Urol 2015; 25:499-509. [DOI: 10.1016/j.purol.2015.04.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2014] [Revised: 04/27/2015] [Accepted: 04/29/2015] [Indexed: 01/25/2023]
|
34
|
Sea JC, Bahler CD, Ring JD, Amstutz S, Sanghvi NT, Cheng L, Sundaram CP. Calibration of a Novel, Laparoscopic, 12-mm, Ultrasound, Image-guided, High-intensity Focused Ultrasound Probe for Ablation of Renal Neoplasms. Urology 2015; 85:953-8. [DOI: 10.1016/j.urology.2014.10.063] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2014] [Revised: 09/29/2014] [Accepted: 10/14/2014] [Indexed: 12/25/2022]
|
35
|
Abstract
High intensity focused ultrasound (HIFU), is a promising, non-invasive modality for treatment of tumours in conjunction with magnetic resonance imaging or diagnostic ultrasound guidance. HIFU is being used increasingly for treatment of prostate cancer and uterine fibroids. Over the last 10 years a growing number of clinical trials have examined HIFU treatment of both benign and malignant tumours of the liver, breast, pancreas, bone, connective tissue, thyroid, parathyroid, kidney and brain. For some of these emerging indications, HIFU is poised to become a serious alternative or adjunct to current standard treatments--including surgery, radiation, gene therapy, immunotherapy, and chemotherapy. Current commercially available HIFU devices are marketed for their thermal ablation applications. In the future, lower energy treatments may play a significant role in mediating targeted drug and gene delivery for cancer treatment. In this article we introduce currently available HIFU systems, provide an overview of clinical trials in emerging oncological targets, and briefly discuss selected pre-clinical research that is relevant to future oncological HIFU applications.
Collapse
Affiliation(s)
- Ezekiel Maloney
- Department of Radiology, University of Washington , Seattle and
| | | |
Collapse
|
36
|
Wei H, Shi L, Zhang J, Xia Y, Cuan J, Zhang Y, Li W, Yan A, Jiang X, Lang MF, Sun J. High-intensity focused ultrasound leads to histopathologic changes of the inferior turbinate mucosa with allergic inflammation. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:2425-2430. [PMID: 25130451 DOI: 10.1016/j.ultrasmedbio.2014.05.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2014] [Revised: 04/21/2014] [Accepted: 05/19/2014] [Indexed: 06/03/2023]
Abstract
This study was aimed at understanding the histopathologic changes that occur in the nasal mucosa of patients with perennial allergic rhinitis after high-intensity focused ultrasound (HIFU) treatment. Biopsy specimens of the inferior turbinate mucosa were taken from 11 PAR patients before, immediately after and 1 y after HIFU treatment. Morphometric analysis revealed that the density of eosinophils and other inflammatory cells increased immediately after treatment and then were decreased significantly 1 y post-treatment. Submucosal glands were swollen and venous sinusoids were dilated, but there was no statistically significant change in their density, immediately after treatment. However, both glands and venous sinusoids significantly decreased in number 1 y after HIFU treatment. The ciliated epithelium or basement membrane of the nasal mucosa was well preserved at all stages. In conclusion, HIFU is a tolerable and effective treatment to reduce inflammation of the inferior turbinate mucosa in patients with perennial allergic rhinitis.
Collapse
Affiliation(s)
- Hongquan Wei
- Department of Otolaryngology, First Hospital of China Medical University, Shenyang, Liaoning, China.
| | - Lei Shi
- Department of Otolaryngology, First Hospital of China Medical University, Shenyang, Liaoning, China
| | - Jingru Zhang
- Department of Otolaryngology, First Hospital of China Medical University, Shenyang, Liaoning, China
| | - Yan Xia
- Department of Otolaryngology, First Hospital of China Medical University, Shenyang, Liaoning, China
| | - Jingjing Cuan
- Department of Otolaryngology, First Hospital of China Medical University, Shenyang, Liaoning, China
| | - Yong Zhang
- Department of Pathology, College of Basic Medical Sciences, China Medical University, Shenyang, Liaoning, China
| | - Wei Li
- Department of Otolaryngology, First Hospital of China Medical University, Shenyang, Liaoning, China
| | - Aihui Yan
- Department of Otolaryngology, First Hospital of China Medical University, Shenyang, Liaoning, China
| | - Xuejun Jiang
- Department of Otolaryngology, First Hospital of China Medical University, Shenyang, Liaoning, China
| | - Ming-Fei Lang
- Department of Physiology, Dalian University Medical School, Dalian, Liaoning, China.
| | - Jing Sun
- Department of Otolaryngology, First Hospital of China Medical University, Shenyang, Liaoning, China.
| |
Collapse
|
37
|
Zhegalova NG, Dergunov SA, Wang ST, Pinkhassik E, Berezin MY. Design of fluorescent nanocapsules as ratiometric nanothermometers. Chemistry 2014; 20:10292-7. [PMID: 25044240 PMCID: PMC5477229 DOI: 10.1002/chem.201402828] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2014] [Indexed: 12/11/2022]
Abstract
We have developed a novel design of optical nanothermometers that can measure the surrounding temperature in the range of 20-85 °C. The nanothermometers comprise two organic fluorophores encapsulated in a crosslinked polymethacrylate nanoshell. The role of the nanocapsule shell around the fluorophores is to form a well-defined and stable microenvironment to prevent other factors besides temperature from affecting the dyes' fluorescence. The two fluorophores feature different temperature-dependent emission profiles; a fluorophore with relatively insensitive fluorescence (rhodamine 640) serves as a reference whereas a sensitive fluorophore (indocyanine green) serves as a sensor. The sensitivity of the nanothermometers depends on the type of nanocapsule-forming lipid and is affected by the phase transition temperature. Both the fluorescence intensity and the fluorescence lifetime can be utilized to measure the temperature.
Collapse
Affiliation(s)
- Natalia G Zhegalova
- Department of Radiology, Washington University in St. Louis School of Medicine, St. Louis, MO 63110 (USA), Fax: (+1) 314-747-5191
| | | | | | | | | |
Collapse
|
38
|
Ukimura O, de Castro Abreu AL, Matsugasumi T, Shoji S, Ma Y, Gill IS. Robot-assisted laparoscopic high-intensity focused ultrasound for focal therapy of prostate: novel approach. Int J Urol 2014; 21:1289-90. [PMID: 25041288 DOI: 10.1111/iju.12560] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Osamu Ukimura
- USC Institute of Urology, University of Southern California, Los Angeles, California, USA
| | | | | | | | | | | |
Collapse
|
39
|
Abstract
Thermal ablative technologies have evolved considerably in the recent past and are now an important component of current clinical guidelines for the treatment of small renal masses. Both radiofrequency ablation and cryoablation have intermediate-term oncologic control that rivals surgical options, with favorable complication profiles. Studies comparing cryoablation and radiofrequency ablation show no significant difference in oncologic control or complication profile between the two modalities. Early data from small series with microwave ablation have shown similar promising results. Newer technologies including irreversible electroporation and high-intensity-focused ultrasound have theoretical advantages, but will require further research before becoming a routine part of the ablation armamentarium. The purpose of this review article is to discuss the current ablative technologies available, briefly review their mechanisms of action, discuss technical aspects of each, and provide current data supporting their use.
Collapse
Affiliation(s)
- Vishal Khiatani
- Coastal Radiology Associates, Department of Radiology, Carolina East Medical Center, New Bern, North Carolina
| | - Robert G Dixon
- Department of Radiology, University of North Carolina, Chapel Hill, North Carolina
| |
Collapse
|
40
|
Klatte T, Kroeger N, Zimmermann U, Burchardt M, Belldegrun AS, Pantuck AJ. The contemporary role of ablative treatment approaches in the management of renal cell carcinoma (RCC): focus on radiofrequency ablation (RFA), high-intensity focused ultrasound (HIFU), and cryoablation. World J Urol 2014; 32:597-605. [PMID: 24700308 DOI: 10.1007/s00345-014-1284-7] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2013] [Accepted: 03/17/2014] [Indexed: 12/25/2022] Open
Abstract
INTRODUCTION Currently, most of renal tumors are small, low grade, with a slow growth rate, a low metastatic potential, and with up to 30 % of these tumors being benign on the final pathology. Moreover, they are often diagnosed in elderly patients with preexisting medical comorbidities in whom the underlying medical conditions may pose a greater risk of death than the small renal mass. Concerns regarding overdiagnosis and overtreatment of patients with indolent small renal tumors have led to an increasing interest in minimally invasive, ablative as an alternative to extirpative interventions for selected patients. OBJECTIVE To provide an overview about the state of the art in radiofrequency ablation (RFA), high-intensity focused ultrasound, and cryoablation in the clinical management of renal cell carcinoma. METHODS A PubMed wide the literature search of was conducted. RESULTS International consensus panels recommend ablative techniques in patients who are unfit for surgery, who are not considered candidates for or elect against elective surveillance, and who have small renal masses. The most often used techniques are cryoablation and RFA. These ablative techniques offer potentially curative outcomes while conferring several advantages over extirpative surgery, including improved patient procedural tolerance, faster recovery, preservation of renal function, and reduction in the risk of intraoperative and postsurgical complications. While it is likely that outcomes associated with ablative modalities will improve with further advances in technology, their application will expand to more elective indications as longer-term efficacy data become available. CONCLUSION Ablative techniques pose a valid treatment option in selected patients.
Collapse
Affiliation(s)
- Tobias Klatte
- Department of Urology, Medical University of Vienna, Vienna, Austria
| | | | | | | | | | | |
Collapse
|
41
|
McClintic AM, Garcia JB, Gofeld M, Kliot M, Kucewicz JC, Loeser JD, Pederson KD, Sparks RE, Terman GW, Tych RE, Mourad PD. Intense focused ultrasound stimulation can safely stimulate inflamed subcutaneous tissue and assess allodynia. J Ther Ultrasound 2014; 2:8. [PMID: 25516804 PMCID: PMC4265992 DOI: 10.1186/2050-5736-2-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2013] [Accepted: 01/30/2014] [Indexed: 01/11/2023] Open
Abstract
Background Potential peripheral sources of deep pain can require invasive evocative tests for their assessment. Here we perform research whose ultimate goal is development of a non-invasive evocative test for deep painful tissue. Methods We used a rat model of inflammation to show that intense focused ultrasound (iFU) differentially stimulates inflamed versus control tissue and can identify allodynia. To do so we applied iFU to inflamed and normal tissue below the skin of rats’ hind paws and measured the amount of ultrasound necessary to induce paw withdrawal. Results iFU of sufficient strength (spatial and temporal average intensities ranged from 100–350 W/cm2) caused the rat to withdraw its inflamed paw, while the same iFU applied to the contralateral paw failed to induce withdrawal, with sensitivity and specificity generally greater than 90%. iFU stimulation of normal tissue required twice the amount of ultrasound to generate a withdrawal than did inflamed tissue, thereby assessing allodynia. Finally, we verified in a preliminary way the safety of iFU stimulation with acute histological studies coupled with mathematical simulations. Conclusions Given that there exist systems to guide iFU deep to the skin, image-guided iFU may one day allow assessment of patient’s deep, peripheral pain generators.
Collapse
Affiliation(s)
- Abbi M McClintic
- Department of Neurological Surgery, University of Washington, Box 356470, Seattle, WA, USA
| | - Josephine B Garcia
- Department of Neurological Surgery, University of Washington, Box 356470, Seattle, WA, USA
| | - Michael Gofeld
- Department of Neurological Surgery, University of Washington, Box 356470, Seattle, WA, USA ; Department of Anesthesiology and Pain Management, University of Washington, Seattle, WA, USA
| | - Michel Kliot
- Department of Neurological Surgery, University of Washington, Box 356470, Seattle, WA, USA
| | - John C Kucewicz
- Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| | - John D Loeser
- Department of Neurological Surgery, University of Washington, Box 356470, Seattle, WA, USA ; Department of Anesthesiology and Pain Management, University of Washington, Seattle, WA, USA
| | - Kristin D Pederson
- Department of Neurological Surgery, University of Washington, Box 356470, Seattle, WA, USA
| | - Rachel E Sparks
- Department of Neurological Surgery, University of Washington, Box 356470, Seattle, WA, USA ; Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| | - Gregory W Terman
- Department of Anesthesiology and Pain Management, University of Washington, Seattle, WA, USA
| | - Rowen E Tych
- Department of Neurological Surgery, University of Washington, Box 356470, Seattle, WA, USA
| | - Pierre D Mourad
- Department of Neurological Surgery, University of Washington, Box 356470, Seattle, WA, USA ; Applied Physics Laboratory, University of Washington, Seattle, WA, USA ; Department of Bioengineering, University of Washington, Seattle, WA, USA
| |
Collapse
|
42
|
Dervishi E, Larrat B, Pernot M, Adam C, Marie Y, Fink M, Delattre JY, Boch AL, Tanter M, Aubry JF. Transcranial high intensity focused ultrasound therapy guided by 7 TESLA MRI in a rat brain tumour model: a feasibility study. Int J Hyperthermia 2013; 29:598-608. [PMID: 23941242 DOI: 10.3109/02656736.2013.820357] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
PURPOSE Transcranial high intensity focused ultrasound (HIFU) therapy guided by magnetic resonance imaging (MRI) is a promising approach for the treatment of brain tumours. Our objective is to validate a dedicated therapy monitoring system for rodents for transcranial HIFU therapy under MRI guidance in an in vivo brain tumour model. MATERIALS AND METHODS A dedicated MR-compatible ultrasound therapy system and positioning frame was developed. Three MR-compatible prefocused ultrasonic monoelement transducers were designed, operating at 1.5 MHz and 2.5 MHz with different geometries. A full protocol of transcranial HIFU brain therapy under MRI guidance was applied in n = 19 rats without and n = 6 rats with transplanted tumours (RG2). Different heating strategies were tested. After treatment, histological study of the brain was performed in order to confirm thermal lesions. RESULTS Relying on a larger aperture and a higher frequency, the 2.5 MHz transducer was found to give better results than other ones. This single element transducer optimised the ratio of the temperature elevation at the focus to the one at the skull surface. Using optimised transducer and heating strategies enabled thermal necrosis both in normal and tumour tissues as verified by histology while limiting overheating in the tissues in contact with the skull. CONCLUSIONS In this study, a system for transcranial HIFU therapy guided by MRI was developed and tested in an in vivo rat brain tumour model. The feasibility of this therapy set-up to induce thermal lesions within brain tumours was demonstrated.
Collapse
Affiliation(s)
- Elvis Dervishi
- Centre de Recherche de l'Institut du Cerveau et de la Moelle Épinière, INSERM - UMRS 975, CNRS 7225, Hôpital de la Pitié-Salpêtrière, Paris
| | | | | | | | | | | | | | | | | | | |
Collapse
|
43
|
McClintic AM, Dickey TC, Gofeld M, Illian PR, Kliot M, Kucewicz JC, Loeser JD, Richebe PG, Mourad PD. Rapid ultrasonic stimulation of inflamed tissue with diagnostic intent. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 134:1521-1529. [PMID: 23927192 PMCID: PMC3745493 DOI: 10.1121/1.4812872] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2012] [Revised: 02/06/2013] [Accepted: 02/08/2013] [Indexed: 06/02/2023]
Abstract
Previous studies have observed that individual pulses of intense focused ultrasound (iFU) applied to inflamed and normal tissue can generate sensations, where inflamed tissue responds at a lower intensity than normal tissue. It was hypothesized that successively applied iFU pulses will generate sensation in inflamed tissue at a lower intensity and dose than application of a single iFU pulse. This hypothesis was tested using an animal model of chronic inflammatory pain, created by injecting an irritant into the rat hind paw. Ultrasound pulses were applied in rapid succession or individually to rats' rear paws beginning at low peak intensities and progressing to higher peak intensities, until the rats withdrew their paws immediately after iFU application. Focused ultrasound protocols consisting of successively and rapidly applied pulses elicited inflamed paw withdrawal at lower intensity and estimated tissue displacement values than single pulse protocols. However, both successively applied pulses and single pulses produced comparable threshold acoustic dose values and estimates of temperature increases. This raises the possibility that temperature increase contributed to paw withdrawal after rapid iFU stimulation. While iFU-induction of temporal summation may also play a role, electrophysiological studies are necessary to tease out these potential contributors to iFU stimulation.
Collapse
Affiliation(s)
- Abbi M McClintic
- Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, Washington 98105, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
44
|
|
45
|
Wang YN, Khokhlova T, Bailey M, Hwang JH, Khokhlova V. Histological and biochemical analysis of mechanical and thermal bioeffects in boiling histotripsy lesions induced by high intensity focused ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:424-38. [PMID: 23312958 PMCID: PMC3570648 DOI: 10.1016/j.ultrasmedbio.2012.10.012] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2012] [Revised: 10/10/2012] [Accepted: 10/15/2012] [Indexed: 05/07/2023]
Abstract
Recent studies have shown that shockwave heating and millisecond boiling in high-intensity focused ultrasound fields can result in mechanical fractionation or emulsification of tissue, termed boiling histotripsy. Visual observations of the change in color and contents indicated that the degree of thermal damage in the emulsified lesions can be controlled by varying the parameters of the exposure. The goal of this work was to examine thermal and mechanical effects in boiling histotripsy lesions using histologic and biochemical analysis. The lesions were induced in ex vivo bovine heart and liver using a 2-MHz single-element transducer operating at duty factors of 0.005-0.01, pulse durations of 5-500 ms and in situ shock amplitude of 73 MPa. Mechanical and thermal damage to tissue was evaluated histologically using conventional staining techniques (hematoxylin and eosin, and nicotinamide adenine dinucleotide-diaphorase). Thermal effects were quantified by measuring denaturation of salt soluble proteins in the treated region. According to histologic analysis, the lesions that visually appeared as a liquid contained no cellular structures larger than a cell nucleus and had a sharp border of one to two cells. Both histologic and protein analysis showed that lesions obtained with short pulses (<10 ms) did not contain any thermal damage. Increasing the pulse duration resulted in an increase in thermal damage. However, both protein analysis and nicotinamide adenine dinucleotide-diaphorase staining showed less denaturation than visually observed as whitening of tissue. The number of high-intensity focused ultrasound pulses delivered per exposure did not change the lesion shape or the degree of thermal denaturation, whereas the size of the lesion showed a saturating behavior suggesting optimal exposure duration. This study confirmed that boiling histotripsy offers an effective, predictable way to non-invasively fractionate tissue into sub-cellular fragments with or without inducing thermal damage.
Collapse
Affiliation(s)
- Yak-Nam Wang
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle WA 98105
| | - Tatiana Khokhlova
- , Tel: +1 206 543 61 93, Fax: +1 206 543 67 85, Division of Gastroenterology, Department of Medicine, University of Washington, 1959 NE Pacific Street, Seattle, WA, 98195 and Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle WA 98105
| | - Michael Bailey
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle WA 98105
| | - Joo Ha Hwang
- Division of Gastroenterology, Department of Medicine, University of Washington, 1959 NE Pacific Street, Seattle, WA, 98195 and Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle WA 98105
| | - Vera Khokhlova
- Department of Acoustics, Physics Faculty, Moscow State University, Leninskie Gory, Moscow 119991, Russia and Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle WA 98105
| |
Collapse
|
46
|
Malietzis G, Monzon L, Hand J, Wasan H, Leen E, Abel M, Muhammad A, Price P, Abel P. High-intensity focused ultrasound: advances in technology and experimental trials support enhanced utility of focused ultrasound surgery in oncology. Br J Radiol 2013; 86:20130044. [PMID: 23403455 DOI: 10.1259/bjr.20130044] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
High-intensity focused ultrasound (HIFU) is a rapidly maturing technology with diverse clinical applications. In the field of oncology, the use of HIFU to non-invasively cause tissue necrosis in a defined target, a technique known as focused ultrasound surgery (FUS), has considerable potential for tumour ablation. In this article, we outline the development and underlying principles of HIFU, overview the limitations and commercially available equipment for FUS, then summarise some of the recent technological advances and experimental clinical trials that we predict will have a positive impact on extending the role of FUS in cancer therapy.
Collapse
Affiliation(s)
- G Malietzis
- Department of Surgery and Cancer, Faculty of Medicine, Imperial College, London, UK
| | | | | | | | | | | | | | | | | |
Collapse
|
47
|
Pacella CM, Papini E. Image-guided percutaneous ablation therapies for local recurrences of thyroid tumors. J Endocrinol Invest 2013; 36:61-70. [PMID: 23391859 DOI: 10.1007/bf03346744] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
The incidence of thyroid carcinoma has increased steadily over the last few decades. Most differentiated thyroid carcinomas (DTC) are cured thanks to the initial treatment with surgery and radioiodine therapy. Nevertheless, neck lymph node metastases are found in a few of these patients during their long-term clinical and ultrasound follow-up. In some of these cases radioiodine treatment may not be effective in eradicating nodal metastases due to scant 131-I uptake. Additionally, a few of these patients undergo repeated neck explorations and/or resections. Based on these considerations and on the frequently indolent course of DTC neck metastases, a non-surgical therapeutic approach should be considered to control small local foci of DTC. There is increasing interest in mini-invasive image-guided procedures that can be performed under local anesthesia which do not affect the performance status of the patient. Image-guided minimally invasive ablative therapies delivered by using needle-like applicators include both thermal and non-thermal source techniques. Over the past 25 years, these therapies have gained widespread attention and, in many cases, broad clinical acceptance as methods for treating focal malignancies. In an attempt to overcome the limitations of treating certain unresectable tumor types not amenable to a further surgical treatment, a few investigators have reported successfully combining percutaneous therapies with other oncologic treatment strategies (combined treatments). In this review, we reported mini-invasive techniques more commonly employed in selected cases to ameliorate local compressive symptoms, control hormonal production, and reduce the volume of neoplastic tissue prior to traditional palliative treatment.
Collapse
Affiliation(s)
- C M Pacella
- Department of Diagnostic Imaging and Interventional Radiology, Regina Apostolorum Hospital, Via San Francesco 50, Albano Laziale - Rome, Italy.
| | | |
Collapse
|
48
|
Wei H, Zhang Y, Shi L, Zhang J, Xia Y, Zang J, Yan A, Li W, Jiang X. Higher dosage of HIFU treatment may lead to higher and longer efficacy for moderate to severe perennial allergic rhinitis. Int J Med Sci 2013; 10:1914-20. [PMID: 24324369 PMCID: PMC3856383 DOI: 10.7150/ijms.7117] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2013] [Accepted: 11/11/2013] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES This study was to compare the efficacies and side effects of high intensity focused ultrasound (HIFU) treatment for perennial allergic rhinitis (PAR) with regular and increased dosage. STUDY DESIGN A prospectively assembled cohort was retrospectively analyzed through visual analogue scale (VAS). METHODS Regular dosage of HIFU treatment was applied to 56 PAR patients in group A. An increased dosage as twice as the regular one was applied to 48 patients in group B. Nasal obstruction, sneezing, rhinorrhea and rhinocnesmus, which were recognized as the four main symptoms of allergic rhinitis (AR), were evaluated before treatment, 3 months after treatment, and 1 year after treatment. The satisfaction of patients was also evaluated at 1 year postoperatively. Biopsy of the inferior turbinate and morphometric analysis were applied to 11 patients in group A and 10 in group B before HIFU treatment and 3 months after treatment. RESULTS Comparing the AR symptoms before treatment, There is no statistical difference observed between group A and B (p>0.05). The four main symptoms at 3 months and 1 year after treatment were all significantly improved (p<0.01) in both group A and B. The VAS scores of AR symptoms in Group B were lower than those in Group A at the same stage after treatment, especially at 1 year after treatment (p<0.05). Comparing the results at 3 months and 1 year after treatment, a tendency of recurrence of these symptoms was observed statistically in group A (p<0.05), but not in group B (p>0.05). More cases of nasal dryness and perirhinal swelling were found in group B than those in group A (p<0.05), while all side effects were mild and temporary. Patients in group B were more satisfied than those in group A (p=0.0866 >0.05), though not statistically significant. More reduction of the eosinophils, other inflammatory cells, and the submucosal glands was observed after HIFU treatment in group B than that in group A (p<0.05). CONCLUSIONS A proper increment of HIFU dosage may be recommended to meet the needs of more improvement of AR symptoms and less recurrence.
Collapse
Affiliation(s)
- Hongquan Wei
- 1. Department of Otolaryngology, The First Hospital of China Medical University, Shenyang, Liaoning 110001, P.R. China
| | | | | | | | | | | | | | | | | |
Collapse
|
49
|
Krol S, Macrez R, Docagne F, Defer G, Laurent S, Rahman M, Hajipour MJ, Kehoe PG, Mahmoudi M. Therapeutic Benefits from Nanoparticles: The Potential Significance of Nanoscience in Diseases with Compromise to the Blood Brain Barrier. Chem Rev 2012; 113:1877-903. [DOI: 10.1021/cr200472g] [Citation(s) in RCA: 158] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Silke Krol
- Fondazione IRCCS Institute of Neurology “Carlo Besta”, Milan, Italy
| | - Richard Macrez
- Inserm U919, University Caen Basse Normandie, Serine Proteases and Pathophysiology of the Neurovascular Unit, GIP CYCERON, F-14074 Caen, France
- Department of Neurology, University Hospital of Caen, Caen, France
| | - Fabian Docagne
- Inserm U919, University Caen Basse Normandie, Serine Proteases and Pathophysiology of the Neurovascular Unit, GIP CYCERON, F-14074 Caen, France
| | - Gilles Defer
- Inserm U919, University Caen Basse Normandie, Serine Proteases and Pathophysiology of the Neurovascular Unit, GIP CYCERON, F-14074 Caen, France
- Department of Neurology, University Hospital of Caen, Caen, France
| | - Sophie Laurent
- Department of General, Organic, and Biomedical Chemistry, NMR and Molecular Imaging Laboratory, University of Mons, Avenue Maistriau, 19, B-7000 Mons, Belgium
| | - Masoud Rahman
- Laboratory of NanoBio Interactions , Department of Nanotechnology, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| | - Mohammad J. Hajipour
- Laboratory of NanoBio Interactions , Department of Nanotechnology, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| | - Patrick G. Kehoe
- Dementia Research Group, School of Clinical Sciences, Faculty of Medicine and Dentistry, University of Bristol, John James Laboratories, Frenchay Hospital, Bristol, U.K
| | - Morteza Mahmoudi
- Laboratory of NanoBio Interactions , Department of Nanotechnology, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
- Nanotechnology Research Center, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
- Current address: School of Chemical Sciences, University of Illinois at Urbana−Champaign, 600 South Mathews Avenue, Urbana, Illinois 61801, United States
| |
Collapse
|
50
|
Harper JD, Shah A, Mitchell SB, Wang YN, Starr F, Bailey MR, Crum LA. Novel high-intensity focused ultrasound clamp--potential adjunct for laparoscopic partial nephrectomy. J Endourol 2012; 26:1494-9. [PMID: 22788221 DOI: 10.1089/end.2012.0107] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
BACKGROUND AND PURPOSE Partial nephrectomy (PN) can be technically challenging, especially if performed in a minimally invasive manner. Although ultrasound technology has been shown to have therapeutic capabilities, including tissue ablation and hemostasis, it has not gained clinical use in the PN setting. The purpose of this study is to evaluate the ability of a high-intensity ultrasound clamp to create an ablation plane in the kidney providing hemostasis that could potentially aid in laparoscopic PN. METHODS A new instrument was created using a laparoscopic Padron endoscopic exposing retractor. Ultrasound elements were engineered on both sides of the retractor to administer high-intensity ultrasound energy between the two sides of the clamp. This high-intensity focused ultrasound (HIFU) clamp was placed 2 to 2.5 cm from the upper and lower poles of 10 porcine kidneys to evaluate its effectiveness at different levels and duration of energy delivery. PN transection was performed through the distal portion of the clamped margin. Kidneys postintervention and after PN were evaluated and blood loss estimated by weighing gauze placed at the defect. Histologic analysis was performed with hematoxylin and eosin and nicotinamide adenine dinucleotide staining to evaluate for tissue viability and thermal spread. RESULTS Gross parenchymal changes were seen with obvious demarcation between treated and untreated tissue. Increased ultrasound exposure time (10 vs 5 and 2 min), even at lower power settings, was more effective in causing destruction and necrosis of tissue. Transmural ablation was achieved in three of four renal units after 10 minutes of exposure with significantly less blood loss (<2 g vs 30-100 g). Nonviable tissue was confirmed histologically. There was minimal thermal spread outside the clamped margin (1.2-3.2 mm). CONCLUSION In this preliminary porcine evaluation, a novel HIFU clamp induced hemostasis and created an ablation plane in the kidney. This technology could serve as a useful adjunct to laparoscopic PN in the future and potentially obviate the need for renal hilar clamping.
Collapse
Affiliation(s)
- Jonathan D Harper
- Department of Urology, University of Washington School of Medicine, Seattle, Washington, USA.
| | | | | | | | | | | | | |
Collapse
|