1
|
Wu KY, Belaiche M, Wen Y, Choulakian MY, Tran SD. Advancements in Polymer Biomaterials as Scaffolds for Corneal Endothelium Tissue Engineering. Polymers (Basel) 2024; 16:2882. [PMID: 39458711 PMCID: PMC11511139 DOI: 10.3390/polym16202882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2024] [Revised: 09/30/2024] [Accepted: 10/04/2024] [Indexed: 10/28/2024] Open
Abstract
Corneal endothelial dysfunction is a leading cause of vision loss globally, frequently requiring corneal transplantation. However, the limited availability of donor tissues, particularly in developing countries, has spurred on the exploration of tissue engineering strategies, with a focus on polymer biomaterials as scaffolds for corneal endotlhelium regeneration. This review provides a comprehensive overview of the advancements in polymer biomaterials, focusing on their role in supporting the growth, differentiation, and functional maintenance of human corneal endothelial cells (CECs). Key properties of scaffold materials, including optical clarity, biocompatibility, biodegradability, mechanical stability, permeability, and surface wettability, are discussed in detail. The review also explores the latest innovations in micro- and nano-topological morphologies, fabrication techniques such as electrospinning and 3D/4D bioprinting, and the integration of drug delivery systems into scaffolds. Despite significant progress, challenges remain in translating these technologies to clinical applications. Future directions for research are highlighted, including the need for improved biomaterial combinations, a deeper understanding of CEC biology, and the development of scalable manufacturing processes. This review aims to serve as a resource for researchers and clinician-scientists seeking to advance the field of corneal endothelium tissue engineering.
Collapse
Affiliation(s)
- Kevin Y. Wu
- Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada; (K.Y.W.)
| | - Myriam Belaiche
- Faculty of Medicine, University of Montreal, Montreal, QC H3T 1J4, Canada
| | - Ying Wen
- Faculty of Medicine, University of Montreal, Montreal, QC H3T 1J4, Canada
| | - Mazen Y. Choulakian
- Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada; (K.Y.W.)
| | - Simon D. Tran
- Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal, QC H3A 1G1, Canada
| |
Collapse
|
2
|
Chi M, Yuan B, Xie Z, Hong J. The Innovative Biomaterials and Technologies for Developing Corneal Endothelium Tissue Engineering Scaffolds: A Review and Prospect. Bioengineering (Basel) 2023; 10:1284. [PMID: 38002407 PMCID: PMC10669703 DOI: 10.3390/bioengineering10111284] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/21/2023] [Accepted: 10/30/2023] [Indexed: 11/26/2023] Open
Abstract
Corneal transplantation is the only treatment for corneal endothelial blindness. However, there is an urgent need to find substitutes for corneal endothelium grafts due to the global shortage of donor corneas. An emerging research field focuses on the construction of scaffold-based corneal endothelium tissue engineering (CETE). Long-term success in CETE transplantation may be achieved by selecting the appropriate biomaterials as scaffolds of corneal endothelial cells and adding bioactive materials to promote cell activity. This article reviews the research progress of CETE biomaterials in the past 20 years, describes the key characteristics required for corneal endothelial scaffolds, and summarizes the types of materials that have been reported. Based on these, we list feasible improvement strategies for biomaterials innovation. In addition, we describe the improved techniques for the scaffolds' surface topography and drug delivery system. Some promising technologies for constructing CETE are proposed. However, some questions have not been answered yet, and clinical trials and industrialization should be carried out with caution.
Collapse
Affiliation(s)
- Miaomiao Chi
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China; (M.C.); (B.Y.); (Z.X.)
- Key Laboratory of Vision Loss and Restoration, Ministry of Education, Beijing 100191, China
| | - Bowei Yuan
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China; (M.C.); (B.Y.); (Z.X.)
- Key Laboratory of Vision Loss and Restoration, Ministry of Education, Beijing 100191, China
| | - Zijun Xie
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China; (M.C.); (B.Y.); (Z.X.)
- Key Laboratory of Vision Loss and Restoration, Ministry of Education, Beijing 100191, China
| | - Jing Hong
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China; (M.C.); (B.Y.); (Z.X.)
- Key Laboratory of Vision Loss and Restoration, Ministry of Education, Beijing 100191, China
| |
Collapse
|
3
|
Ichikawa K, Tanaka Y, Tokiwa S, Naito A, Hidaka Y, Ichikawa R, Ichikawa K, Yamamoto N. Comparison of INTREPID® balanced and hybrid tips on anterior capsule rupture in ex vivo porcine eyes. PLoS One 2023; 18:e0290657. [PMID: 37643177 PMCID: PMC10464992 DOI: 10.1371/journal.pone.0290657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Accepted: 08/11/2023] [Indexed: 08/31/2023] Open
Abstract
Phacoemulsification has emerged as the global standard for cataract surgery, and various novel methods, tools, and agents have promoted surgical efficiency and reduced complications. Conventionally, the phaco tip, which cleaves and aspirates the cataractous lens, has been mainly constructed of metal. In this study, the risk of anterior capsule rupture was evaluated under conditions of different power modes, longitudinal (Mode-L), torsional (Mode-T), or both (Mode-LT), and different aspiration powers (0 or 200 mmHg), using a traditional metal phaco tip (Group-M) or a new phaco tip with a high-strength polymer overmold on the needle edge (Group-P), which was developed to reduce the risk of capsule rupture. One hundred twenty porcine eyes were used for experiments within a setting of typical human physiological intraocular pressure. We found that Group-M showed capsule rupture with a smaller ultrasound power than did Group-P, regardless of power mode or aspiration power. In Group-M, there was no significant difference in risk of capsule rupture among power modes, however in Group-P, capsule rupture was least likely to occur with Mode-T. These results provide useful information for inexperienced ophthalmologists to improve surgical safety.
Collapse
Affiliation(s)
- Kei Ichikawa
- Chukyo Eye Clinic, Nagoya, Aichi, Japan
- General Aoyama Hospital, Toyokawa, Aichi, Japan
| | | | | | | | | | | | | | - Naoki Yamamoto
- Support Office for Bioresource Research, Center for Translational Research, Translational Research Headquarters, Fujita Health University, Toyoake, Aichi, Japan
- International Center for Cell and Gene Therapy, Research Promotion Headquarters, Fujita Health University, Toyoake, Aichi, Japan
| |
Collapse
|
4
|
Hazra S, Dey S, Mandal BB, Ramachandran C. In Vitro Profiling of the Extracellular Matrix and Integrins Expressed by Human Corneal Endothelial Cells Cultured on Silk Fibroin-Based Matrices. ACS Biomater Sci Eng 2023; 9:2438-2451. [PMID: 37023465 DOI: 10.1021/acsbiomaterials.2c01566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/08/2023]
Abstract
Developing a scaffold for culturing human corneal endothelial (HCE) cells is crucial as an alternative cell therapeutic approach to bridge the growing gap between the demand and availability of healthy donor corneas for transplantation. Silk films are promising substrates for the culture of these cells; however, their tensile strength is several-fold greater than the native basement membrane which can possibly influence the dynamics of cell-matrix interaction and the extracellular matrix (ECM) secreted by the cells in long-term culture. In our current study, we assessed the secretion of ECM and the expression of integrins by the HCE cells on Philosamia ricini (PR) and Antheraea assamensis (AA) silk films and fibronectin-collagen (FNC)-coated plastic dishes to understand the cell-ECM interaction in long-term culture. The expression of ECM proteins (collagens 1, 4, 8, and 12, laminin, and fibronectin) on silk was comparable to that on the native tissue. The thicknesses of collagen 8 and laminin at 30 days on both PR (4.78 ± 0.55 and 5.53 ± 0.51 μm, respectively) and AA (4.66 ± 0.72 and 5.71 ± 0.61 μm, respectively) were comparable with those of the native tissue (4.4 ± 0.63 and 5.28 ± 0.72 μm, respectively). The integrin expression by the cells on the silk films was also comparable to that on the native tissue, except for α3 whose fluorescence intensity was significantly higher on PR (p ≤ 0.01) and AA (p ≤ 0.001), compared to that on the native tissue. This study shows that the higher tensile strength of the silk films does not alter the ECM secretion or cell phenotype in long-term culture, confirming the suitability of using this material for engineering the HCE cells for transplantation.
Collapse
Affiliation(s)
- Swatilekha Hazra
- Hyderabad Eye Research Foundation, LV Prasad Eye Institute, Hyderabad 500034, India
- Manipal Academy of Higher Education, Manipal 576104, India
| | - Souradeep Dey
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
| | - Biman B Mandal
- Biomaterials and Tissue Engineering Laboratory, Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
- Jyoti and Bhupat Mehta School of Health Sciences & Technology, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
| | | |
Collapse
|
5
|
Bosch BM, Bosch-Rue E, Perpiñan-Blasco M, Perez RA. Design of functional biomaterials as substrates for corneal endothelium tissue engineering. Regen Biomater 2022; 9:rbac052. [PMID: 35958516 PMCID: PMC9362998 DOI: 10.1093/rb/rbac052] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 06/29/2022] [Accepted: 07/16/2022] [Indexed: 11/12/2022] Open
Abstract
Corneal endothelium defects are one of the leading causes of blindness worldwide. The actual treatment is transplantation, which requires the use of human cadaveric donors, but it faces several problems, such as global shortage of donors. Therefore, new alternatives are being developed and, among them, cell therapy has gained interest in the last years due to its promising results in tissue regeneration. Nevertheless, the direct administration of cells may sometimes have limited success due to the immune response, hence requiring the combination with extracellular mimicking materials. In this review, we present different methods to obtain corneal endothelial cells from diverse cell sources such as pluripotent or multipotent stem cells. Moreover, we discuss different substrates in order to allow a correct implantation as a cell sheet and to promote an enhanced cell behavior. For this reason, natural or synthetic matrixes that mimic the native environment have been developed. These matrixes have been optimized in terms of their physicochemical properties, such as stiffness, topography, composition and transparency. To further enhance the matrixes properties, these can be tuned by incorporating certain molecules that can be delivered in a sustained manner in order to enhance biological behavior. Finally, we elucidate future directions for corneal endothelial regeneration, such as 3D printing, in order to obtain patient-specific substrates.
Collapse
Affiliation(s)
- Begona M Bosch
- Universitat Internacional de Catalunya Bioengineering Institute of Technology (BIT), , Sant Cugat del Valles, Barcelona, 08195, Spain
| | - Elia Bosch-Rue
- Universitat Internacional de Catalunya Bioengineering Institute of Technology (BIT), , Sant Cugat del Valles, Barcelona, 08195, Spain
| | - Marina Perpiñan-Blasco
- Universitat Internacional de Catalunya Bioengineering Institute of Technology (BIT), , Sant Cugat del Valles, Barcelona, 08195, Spain
| | - Roman A Perez
- Universitat Internacional de Catalunya Bioengineering Institute of Technology (BIT), , Sant Cugat del Valles, Barcelona, 08195, Spain
| |
Collapse
|
6
|
Jain P, Rauer SB, Möller M, Singh S. Mimicking the Natural Basement Membrane for Advanced Tissue Engineering. Biomacromolecules 2022; 23:3081-3103. [PMID: 35839343 PMCID: PMC9364315 DOI: 10.1021/acs.biomac.2c00402] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022]
Abstract
![]()
Advancements in the field of tissue engineering have
led to the
elucidation of physical and chemical characteristics of physiological
basement membranes (BM) as specialized forms of the extracellular
matrix. Efforts to recapitulate the intricate structure and biological
composition of the BM have encountered various advancements due to
its impact on cell fate, function, and regulation. More attention
has been paid to synthesizing biocompatible and biofunctional fibrillar
scaffolds that closely mimic the natural BM. Specific modifications
in biomimetic BM have paved the way for the development of in vitro models like alveolar-capillary barrier, airway
models, skin, blood-brain barrier, kidney barrier, and metastatic
models, which can be used for personalized drug screening, understanding
physiological and pathological pathways, and tissue implants. In this
Review, we focus on the structure, composition, and functions of in vivo BM and the ongoing efforts to mimic it synthetically.
Light has been shed on the advantages and limitations of various forms
of biomimetic BM scaffolds including porous polymeric membranes, hydrogels,
and electrospun membranes This Review further elaborates and justifies
the significance of BM mimics in tissue engineering, in particular
in the development of in vitro organ model systems.
Collapse
Affiliation(s)
- Puja Jain
- DWI-Leibniz-Institute for Interactive Materials e.V, Aachen 52074, Germany
| | | | - Martin Möller
- DWI-Leibniz-Institute for Interactive Materials e.V, Aachen 52074, Germany
| | - Smriti Singh
- Max-Planck-Institute for Medical Research, Heidelberg 69028, Germany
| |
Collapse
|
7
|
Gupta S, Mahalingam K, Singh A, Selvan H, Somarajan BI, Gupta V. Posterior corneal morphological changes in primary congenital glaucoma. Indian J Ophthalmol 2022; 70:2571-2577. [PMID: 35791159 PMCID: PMC9426191 DOI: 10.4103/ijo.ijo_317_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Purpose: To compare posterior corneal morphology between older treated and younger untreated children with primary congenital glaucoma (PCG) using anterior segment optical coherence tomography (ASOCT) and intraoperative OCT (iOCT), respectively. Methods: In this comparative study, ASOCT of older PCG children were compared with iOCT of younger untreated PCG patients. Differences between the two groups with respect to posterior corneal morphology were studied. Results: Observed morphological patterns within posterior cornea in older treated (age: 72–300 months) children (87 eyes) included Descemet’s membrane (DM) excrescences (70%), thickened DM (35%), intracameral twin protuberances (92%), and DM detachment (26%). Changes within pre-Descemet’s layer (PDL) (28%) included thickening, breaks, and detachments. Extent of Haab’s striae was associated with thickness of DM/PDL complex (P = 0.008) when analyzed in the treated group. In contrast, in the untreated group (n = 53 eyes, age 1–63 months), posterior corneal changes were limited to diffuse hyper-reflectivity of the DM/PDL complex, with absence of DM tears. Conclusion: Posterior cornea thickens and Haab’s striae become more circumscribed in eyes of older treated children compared to untreated PCG eyes, probably reflecting a healing response of posterior cornea over time.
Collapse
Affiliation(s)
- Shikha Gupta
- Glaucoma Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Karthikeyan Mahalingam
- Glaucoma Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Abhishek Singh
- Glaucoma Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Harathy Selvan
- Glaucoma Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Bindu I Somarajan
- Glaucoma Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Viney Gupta
- Glaucoma Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|
8
|
|
9
|
Muench S, Roellig M, Balzani D. A new method for the in vivo identification of degenerated material property ranges of the human eye: feasibility analysis based on synthetic data. Biomech Model Mechanobiol 2022; 21:401-418. [PMID: 34928468 PMCID: PMC8940849 DOI: 10.1007/s10237-021-01541-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Accepted: 11/24/2021] [Indexed: 11/25/2022]
Abstract
This paper proposes a new method for in vivo and almost real-time identification of biomechanical properties of the human cornea based on non-contact tonometer data. Further goal is to demonstrate the method's functionality based on synthetic data serving as reference. For this purpose, a finite element model of the human eye is constructed to synthetically generate full-field displacements from different data sets with keratoconus-like degradations. Then, a new approach based on the equilibrium gap method combined with a mechanical morphing approach is proposed and used to identify the material parameters from virtual test data sets. In a further step, random absolute noise is added to the virtual test data to investigate the sensitivity of the new approach to noise. As a result, the proposed method shows a relevant accuracy in identifying material parameters based on full-field displacements. At the same time, the method turns out to work almost in real time (order of a few minutes on a regular workstation) and is thus much faster than inverse problems solved by typical forward approaches. On the other hand, the method shows a noticeable sensitivity to rather small noise amplitudes rendering the method not accurate enough for the precise identification of individual parameter values. However, analysis show that the accuracy is sufficient for the identification of property ranges which might be related to diseased tissues. Thereby, the proposed approach turns out promising with view to diagnostic purposes.
Collapse
Affiliation(s)
- Stefan Muench
- Department of Testing of Electronics and Optical Methods, Fraunhofer Institute for Ceramic Technologies and Systems IKTS, Dresden, Germany
| | - Mike Roellig
- Department of Testing of Electronics and Optical Methods, Fraunhofer Institute for Ceramic Technologies and Systems IKTS, Dresden, Germany
| | - Daniel Balzani
- Chair of Continuum Mechanics, Ruhr University Bochum, Bochum, Germany.
| |
Collapse
|
10
|
Delaey J, De Vos L, Koppen C, Dubruel P, Van Vlierberghe S, Van den Bogerd B. Tissue engineered scaffolds for corneal endothelial regeneration: a material's perspective. Biomater Sci 2022; 10:2440-2461. [PMID: 35343525 DOI: 10.1039/d1bm02023d] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Currently, the treatment of corneal diseases caused by damage to the corneal endothelium requires a donor cornea. Because of their limited availability (1 donor cornea for 70 patients in need), researchers are investigating alternative approaches that are independent of donor tissue. One of them includes the development of a tissue engineered scaffold onto which corneal endothelial cells are seeded. In order to function as a suitable substrate, some of its essential properties including thickness, permeability, transparency and mechanical strength should meet certain demands. Additionally, the membrane should be biocompatible and allow the formation of a functional endothelium on the surface. Many materials have already been investigated in this regard including natural, semi-synthetic and synthetic polymers. In the current review, we present an overview of their characteristics and provide a critical view on the methods exploited for material characterization. Next, also the suitability of scaffolds to serve their purpose is discussed along with an overview of natural tissues (e.g. amniotic membrane and lens capsule) previously investigated for this application. Eventually, we propose a consistent approach to be exploited ideally for membrane characterization in future research. This will allow a scientifically sound comparison of materials and membranes investigated by different research groups, hence benefitting research towards the creation of a suitable/optimal tissue engineered endothelial graft.
Collapse
Affiliation(s)
- Jasper Delaey
- Polymer Chemistry & Biomaterials Group, Centre of Macromolecular Chemistry (CMaC), Department of Organic and Macromolecular Chemistry, Ghent University, Ghent, Belgium
| | - Lobke De Vos
- Polymer Chemistry & Biomaterials Group, Centre of Macromolecular Chemistry (CMaC), Department of Organic and Macromolecular Chemistry, Ghent University, Ghent, Belgium
| | - Carina Koppen
- Antwerp Research Group for Ocular Science (ARGOS), Translational Neurosciences, Faculty of Medicine, University of Antwerp, Wilrijk, Belgium. .,Department of Ophthalmology, Antwerp University Hospital, Edegem, Belgium
| | - Peter Dubruel
- Polymer Chemistry & Biomaterials Group, Centre of Macromolecular Chemistry (CMaC), Department of Organic and Macromolecular Chemistry, Ghent University, Ghent, Belgium
| | - Sandra Van Vlierberghe
- Polymer Chemistry & Biomaterials Group, Centre of Macromolecular Chemistry (CMaC), Department of Organic and Macromolecular Chemistry, Ghent University, Ghent, Belgium
| | - Bert Van den Bogerd
- Antwerp Research Group for Ocular Science (ARGOS), Translational Neurosciences, Faculty of Medicine, University of Antwerp, Wilrijk, Belgium.
| |
Collapse
|
11
|
Avetisov SE, Osipyan GA, Abukerimova AK, Akovantseva AA, Efremov YM, Frolova AA, Kotova SL, Timashev PS. [Experimental studies of the biomechanical properties of the cornea]. Vestn Oftalmol 2022; 138:124-131. [PMID: 35801891 DOI: 10.17116/oftalma2022138031124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The review presents the results of experimental studies of the biomechanical properties of the cornea. Selective evaluation of the individual corneal structures (for example, limiting membranes) using classical mechanical tests is to a certain extent limited due to the rather small thickness of these structures and the related difficulties in sample fixation. In real practice, the use of a method better adapted for conducting such studies - atomic force microscopy (AFM) - remains promising, since on the one hand it eliminates the need for mechanical capture and retention of the sample, and on the other - provides the capability for studying its segments separately.
Collapse
Affiliation(s)
- S E Avetisov
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
- Research Institute of Eye Diseases, Moscow, Russia
| | - G A Osipyan
- Research Institute of Eye Diseases, Moscow, Russia
| | | | - A A Akovantseva
- Institute of Photonic Technologies of the Crystallography and Photonics Research Center, Moscow, Russia
| | - Yu M Efremov
- Institute of Regenerative Medicine of the I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - A A Frolova
- Digital Biodesign and Personalized Healthcare Center of the I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - S L Kotova
- Institute of Regenerative Medicine of the I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
- N.N. Semenov Federal Research Center for Chemical Physics, Moscow, Russia
| | - P S Timashev
- Institute of Regenerative Medicine of the I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
- Digital Biodesign and Personalized Healthcare Center of the I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
- N.N. Semenov Federal Research Center for Chemical Physics, Moscow, Russia
- Lomonosov Moscow State University, Moscow, Russia
- Institute of Photonic Technologies of the Crystallography and Photonics Research Center, Moscow, Russia
| |
Collapse
|
12
|
Wei H, Wolffsohn JS, Gomes de Oliveira O, Davies LN. An Artificial Lens Capsule with a Lens Radial Stretching System Mimicking Dynamic Eye Focusing. Polymers (Basel) 2021; 13:polym13203552. [PMID: 34685312 PMCID: PMC8540979 DOI: 10.3390/polym13203552] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 10/08/2021] [Accepted: 10/09/2021] [Indexed: 11/17/2022] Open
Abstract
Presbyopia is a common eye disorder among aged people which is attributed to the loss of accommodation of the crystalline lens due to the increasing stiffness. One of the potential techniques to correct presbyopia involves removing the lens substance inside the capsule and replacing it with an artificial lens. The development of such devices, e.g., accommodating intraocular lenses (AIOLs), relies on the understanding of the biomechanical behaviour of the lens capsule and the essential design verification ex vivo. To mimic the eye’s dynamic focusing ability (accommodation), an artificial lens capsule (ALC), from silicone rubber accompanied by a lens radial stretching system (LRSS) was developed. The ALC was manufactured to offer a dimension and deforming behaviour replicating the human lens capsule. The LRSS was calibrated to provide a radial stretch simulating the change of diameter of capsules during accommodating process. The biomechanical function of the ALC was addressed by studying its evolution behaviour and reaction force under multiaxial stretch from the LRSS. The study highlighted the convenience of this application by performing preliminary tests on prototypes of ophthalmic devices (e.g., AIOLs) to restore accommodation.
Collapse
Affiliation(s)
- Huidong Wei
- College of Health and Life Sciences, Aston University, Birmingham B4 7ET, UK;
- Rayner Intraocular Lenses Limited, Worthing BN14 8AQ, UK;
- Correspondence: (H.W.); (J.S.W.); Tel.: +44-(0)121-204-4140 (J.S.W.)
| | - James S. Wolffsohn
- College of Health and Life Sciences, Aston University, Birmingham B4 7ET, UK;
- Correspondence: (H.W.); (J.S.W.); Tel.: +44-(0)121-204-4140 (J.S.W.)
| | | | - Leon N. Davies
- College of Health and Life Sciences, Aston University, Birmingham B4 7ET, UK;
| |
Collapse
|
13
|
Tsai MC, Daniels JT. The impact of biomechanics on corneal endothelium tissue engineering. Exp Eye Res 2021; 209:108690. [PMID: 34216616 DOI: 10.1016/j.exer.2021.108690] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 06/03/2021] [Accepted: 06/29/2021] [Indexed: 11/16/2022]
Abstract
The integrity of innermost layer of the cornea, the corneal endothelium, is key to sustaining corneal transparency. Therefore, disease or injury causing loss or damage to the corneal endothelial cell population may threaten vision. Transplantation of corneal tissue is the standard treatment used to replace malfunctioning corneal endothelial cells. However, this surgery is dependent upon donor tissue, which is limited in supply. Hence, tissue engineers have attempted to construct alternative transplantable tissues or cell therapies to alleviate this problem. Nevertheless, the intrinsic non-dividing nature of corneal endothelial cells continues to foil scientists in their attempts to yield large numbers of cells in the laboratory for use in such novel therapies. Interestingly, the contribution of the biomechanical properties of the underlying extracellular matrix (ECM) on cell division, tissue development and maintenance has been extensively investigated in other many cell types. However, the impact of biomechanics on corneal endothelial cell behaviour is relatively unexplored. Here, we describe contemporary tissue engineering solutions aimed at circumventing donor tissue scarcity. We review the ECM structure and biomechanical features of corneal endothelial cells. We discuss the alterations of ECM in endothelial disease development and progression and point out the role of ECM in developing a tissue-engineered corneal endothelium. We highlight the main biomechanical cues, including topographical and mechanical features, that impact cellular behaviors. Finally, we discuss the influence of biomechanical cues on cell and tissue development, and how corneal endothelial cells response to individual biomechanical stimuli in tissue engineering, which have implications for designing an engineered endothelium and maintaining cell function.
Collapse
Affiliation(s)
- Meng-Chen Tsai
- UCL Institute of Ophthalmology, University College London, London, UK.
| | - Julie T Daniels
- UCL Institute of Ophthalmology, University College London, London, UK
| |
Collapse
|
14
|
Vellara HR, Patel DV. Biomechanical properties of the keratoconic cornea: a review. Clin Exp Optom 2021; 98:31-8. [DOI: 10.1111/cxo.12211] [Citation(s) in RCA: 91] [Impact Index Per Article: 30.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2014] [Revised: 06/12/2014] [Accepted: 06/21/2014] [Indexed: 11/26/2022] Open
Affiliation(s)
- Hans R Vellara
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand,
| | - Dipika V Patel
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand,
| |
Collapse
|
15
|
Avetisov KS, Bakhchieva NA, Avetisov SE, Novikov IA, Shitikova AV, Frolova AA, Timashev PS. [Assessment of age-related changes in lens capsule biomechanics using atomic force microscopy]. Vestn Oftalmol 2021; 137:28-34. [PMID: 33610146 DOI: 10.17116/oftalma202113701128] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Studies devoted to the assessment of lens capsule biomechanics can be divided into fundamental and applied. The former are oriented towards analysis of various indicators characterizing elasticity of the capsule as a basal membrane that maintains and changes the shape of the lens, and the latter deal with widespread introduction of modern microinvasive methods of phaco surgery into clinical practice. PURPOSE To assess age-related changes in lens capsule biomechanics based on atomic force microscopy (AFM). MATERIAL AND METHODS The study included 50 central fragments of the anterior capsule of the human lens obtained intraoperatively during ultrasonic phacoemulsification by continuous circular capsulorhexis. The measurements were carried out in the Fast Force Volume (FFV) mode. The force curves were processed in the Nanoscope Analysis software (Bruker, USA) using the Hertz model that allows calculating the Young's modulus of the capsule sample based on the dependence of the force on the puncture depth. RESULTS There was no statistically significant difference in the «stiffness» of the inner and outer surfaces before and after removal of the subcapsular epithelium (p=0.25). In all cases, the inner surface of the capsule turned out to be «harder» than the outer one. In this case, the ratio of Young's modulus of the inner and outer surfaces has a significant dependence on age (p<0.001). With an increase in age from 50 to 90 years, this ratio decreased from ~7 to ~1.5. This was due to a simultaneous change in Young's modulus of the opposite nature: an increase in the stiffness of the outer surface and its decrease in the inner one. CONCLUSION It is possible to assess lens capsule biomechanics using AFM if the subcapsular epithelium is present. In this case, the objects of study are the areas of the capsule free of epithelium, and the epithelial cells themselves can be used to identify the inner surface of the capsule. Regardless of age, the stiffness of the inner surface of the anterior lens capsule significantly exceeds that of the outer surface.
Collapse
Affiliation(s)
- K S Avetisov
- Research Institute of Eye Diseases, Moscow, Russia
| | | | - S E Avetisov
- Research Institute of Eye Diseases, Moscow, Russia.,I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - I A Novikov
- Research Institute of Eye Diseases, Moscow, Russia
| | | | - A A Frolova
- Institute for Regenerative Medicine of the Sechenov University, Moscow, Russia
| | - P S Timashev
- Institute for Regenerative Medicine of the Sechenov University, Moscow, Russia.,Institute of Photon Technologies of the Federal Scientific Research Centre «Crystallography and Photonics», Moscow, Russia.,N.N. Semenov Institute of Chemical Physics, Moscow, Russia
| |
Collapse
|
16
|
López-Cano JJ, González-Cela-Casamayor MA, Andrés-Guerrero V, Herrero-Vanrell R, Molina-Martínez IT. Liposomes as vehicles for topical ophthalmic drug delivery and ocular surface protection. Expert Opin Drug Deliv 2021; 18:819-847. [PMID: 33412914 DOI: 10.1080/17425247.2021.1872542] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Introduction: The development of ophthalmic formulations able to deliver hydrophilic and hydrophobic drugs to the inner structures of the eye and restore the preocular tear film has been a leading topic of discussion over the last few years. In this sense, liposomes represent a suitable strategy to achieve these objectives in ocular drug delivery.Areas covered: Knowledge of the different physiological and anatomical eye structures, and specially the ocular surface are critical to better understanding and comprehending the characteristics required for the development of topical ophthalmic liposomal formulations. In this review, several features of liposomes are discussed such as the main materials used for their fabrication, basic structure and preparation methods, from already established to novel techniques, allowing the control and design of special characteristics. Besides, physicochemical properties, purification processes and strategies to overcome delivery or encapsulation challenges are also presented. Expert opinion: Regarding ocular drug delivery of liposomes, there are some features that can be redesigned. Specific biocompatible and biodegradable materials presenting therapeutic properties, such as lipidic compounds or polymers significantly change the way of tackling ophthalmic diseases. Besides, liposomes entail an effective, safe and versatile strategy for the treatment of diseases in the clinical practice.
Collapse
Affiliation(s)
- José Javier López-Cano
- Department of Pharmaceutics and Food Technology, Complutense University, Madrid, Spain.,Ocular Pathology National Net (OFTARED) of the Institute of Health Carlos III, Health Research Institute of the San Carlos Clinical Hospital (Idissc), Madrid Spain
| | - Miriam Ana González-Cela-Casamayor
- Department of Pharmaceutics and Food Technology, Complutense University, Madrid, Spain.,Ocular Pathology National Net (OFTARED) of the Institute of Health Carlos III, Health Research Institute of the San Carlos Clinical Hospital (Idissc), Madrid Spain
| | - Vanessa Andrés-Guerrero
- Department of Pharmaceutics and Food Technology, Complutense University, Madrid, Spain.,Ocular Pathology National Net (OFTARED) of the Institute of Health Carlos III, Health Research Institute of the San Carlos Clinical Hospital (Idissc), Madrid Spain
| | - Rocío Herrero-Vanrell
- Department of Pharmaceutics and Food Technology, Complutense University, Madrid, Spain.,Ocular Pathology National Net (OFTARED) of the Institute of Health Carlos III, Health Research Institute of the San Carlos Clinical Hospital (Idissc), Madrid Spain
| | - Irene Teresa Molina-Martínez
- Department of Pharmaceutics and Food Technology, Complutense University, Madrid, Spain.,Ocular Pathology National Net (OFTARED) of the Institute of Health Carlos III, Health Research Institute of the San Carlos Clinical Hospital (Idissc), Madrid Spain
| |
Collapse
|
17
|
Halfter W, Moes S, Halfter K, Schoenenberger MS, Monnier CA, Kalita J, Asgeirsson D, Binggeli T, Jenoe P, Scholl HPN, Henrich PB. The human Descemet's membrane and lens capsule: Protein composition and biomechanical properties. Exp Eye Res 2020; 201:108326. [PMID: 33147472 DOI: 10.1016/j.exer.2020.108326] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2020] [Revised: 10/18/2020] [Accepted: 10/20/2020] [Indexed: 02/07/2023]
Abstract
The Descemet's membrane (DM) and the lens capsule (LC) are two ocular basement membranes (BMs) that are essential in maintaining stability and structure of the cornea and lens. In this study, we investigated the proteomes and biomechanical properties of these two materials to uncover common and unique properties. We also screened for possible protein changes during diabetes. LC-MS/MS was used to determine the proteomes of both BMs. Biomechanical measurements were conducted by atomic force microscopy (AFM) in force spectroscopy mode, and complemented with immunofluorescence microscopy. Proteome analysis showed that all six existing collagen IV chains represent 70% of all LC-protein, and are thus the dominant components of the LC. The DM on the other hand is predominantly composed of a single protein, TGF-induced protein, which accounted for around 50% of all DM-protein. Four collagen IV-family members in DM accounted for only 10% of the DM protein. Unlike the retinal vascular BMs, the LC and DM do not undergo significant changes in their protein compositions during diabetes. Nanomechanical measurements showed that the endothelial/epithelial sides of both BMs are stiffer than their respective stromal/anterior-chamber sides, and both endothelial and stromal sides of the DM were stiffer than the epithelial and anterior-chamber sides of the LC. Long-term diabetes did not change the stiffness of the DM and LC. In summary, our analyses show that the protein composition and biomechanical properties of the DM and LC are different, i.e., the LC is softer than DM despite a significantly higher concentration of collagen IV family members. This finding is unexpected, as collagen IV members are presumed to be responsible for BM stiffness. Diabetes had no significant effect on the protein composition and the biomechanical properties of both the DM and LC.
Collapse
Affiliation(s)
- Willi Halfter
- Department of Ophthalmology, University of Basel, Switzerland.
| | - Suzette Moes
- Proteomics Core Facility, Biozentrum, University of Basel, Switzerland.
| | - Kathrin Halfter
- Munich Cancer Registry, Institute of Medical Informatics, Biometry and Epidemiology, Maximilian University Munich, Germany.
| | | | | | - Joanna Kalita
- Biozentrum and the Swiss Nanoscience Institute, University of Basel, Switzerland
| | - Daphne Asgeirsson
- Biozentrum and the Swiss Nanoscience Institute, University of Basel, Switzerland.
| | | | - Paul Jenoe
- Proteomics Core Facility, Biozentrum, University of Basel, Switzerland.
| | - Hendrik P N Scholl
- Department of Ophthalmology, University of Basel, Switzerland; Institute of Molecular and Clinical Ophthalmology Basel (IOB), Switzerland; Wilmer Eye Institute, Johns Hopkins University, Baltimore, MA, USA.
| | - Paul Bernhard Henrich
- Department of Ophthalmology, University of Basel, Switzerland; Università della Svizzera Italiana, Lugano, Switzerland.
| |
Collapse
|
18
|
Lu Q, Peng RM, Feng N, Wen MD, He LH, Hong J. Evaluation of reconstructed human corneal endothelium sheets made with porcine Descemet's membrane in vitro and in vivo. Exp Eye Res 2020; 197:108125. [DOI: 10.1016/j.exer.2020.108125] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2019] [Revised: 06/01/2020] [Accepted: 06/18/2020] [Indexed: 12/13/2022]
|
19
|
Van Hoorick J, Delaey J, Vercammen H, Van Erps J, Thienpont H, Dubruel P, Zakaria N, Koppen C, Van Vlierberghe S, Van den Bogerd B. Designer Descemet Membranes Containing PDLLA and Functionalized Gelatins as Corneal Endothelial Scaffold. Adv Healthc Mater 2020; 9:e2000760. [PMID: 32603022 DOI: 10.1002/adhm.202000760] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 06/10/2020] [Indexed: 01/08/2023]
Abstract
Corneal blindness is the fourth leading cause of visual impairment. Of specific interest is blindness due to a dysfunctional corneal endothelium which can only be treated by transplanting healthy tissue from a deceased donor. Unfortunately, corneal supply does not meet the demand with only one donor for every 70 patients. Therefore, there is a huge interest in tissue engineering of grafts consisting of an ultra-thin scaffold seeded with cultured endothelial cells. The present research describes the fabrication of such artificial Descemet membranes based on the combination of a biodegradable amorphous polyester (poly (d,l-lactic acid)) and crosslinkable gelatins. Four different crosslinkable gelatin derivatives are compared in terms of processing, membrane quality, and function, as well as biological performance in the presence of corneal endothelial cells. The membranes are fabricated through multi-step spincoating, including a sacrificial layer to allow for straightforward membrane detachment after production. As a consequence, ultrathin (<1 µm), highly transparent (>90%), semi-permeable membranes could be obtained with high biological potential. The membranes supported the characteristic morphology and correct phenotype of corneal endothelial cells while exhibiting similar proliferation rates as the positive control. As a consequence, the proposed membranes prove to be a promising synthetic alternative to donor tissue.
Collapse
Affiliation(s)
- Jasper Van Hoorick
- Polymer Chemistry & Biomaterials GroupCentre of Macromolecular Chemistry (CMaC)Department of Organic and Macromolecular ChemistryGhent University Ghent 9000 Belgium
- Brussels PhotonicsDepartment of Applied Physics and PhotonicsVrije Universiteit Brussel and Flanders Make Brussels 1050 Belgium
| | - Jasper Delaey
- Polymer Chemistry & Biomaterials GroupCentre of Macromolecular Chemistry (CMaC)Department of Organic and Macromolecular ChemistryGhent University Ghent 9000 Belgium
| | - Hendrik Vercammen
- Antwerp Research Group for Ocular Science (ARGOS)Translational NeurosciencesFaculty of MedicineUniversity of Antwerp Wilrijk 2610 Belgium
| | - Jürgen Van Erps
- Brussels PhotonicsDepartment of Applied Physics and PhotonicsVrije Universiteit Brussel and Flanders Make Brussels 1050 Belgium
| | - Hugo Thienpont
- Polymer Chemistry & Biomaterials GroupCentre of Macromolecular Chemistry (CMaC)Department of Organic and Macromolecular ChemistryGhent University Ghent 9000 Belgium
- Brussels PhotonicsDepartment of Applied Physics and PhotonicsVrije Universiteit Brussel and Flanders Make Brussels 1050 Belgium
| | - Peter Dubruel
- Polymer Chemistry & Biomaterials GroupCentre of Macromolecular Chemistry (CMaC)Department of Organic and Macromolecular ChemistryGhent University Ghent 9000 Belgium
| | - Nadia Zakaria
- Antwerp Research Group for Ocular Science (ARGOS)Translational NeurosciencesFaculty of MedicineUniversity of Antwerp Wilrijk 2610 Belgium
- Department of OphthalmologyAntwerp University Hospital Edegem 2650 Belgium
| | - Carina Koppen
- Antwerp Research Group for Ocular Science (ARGOS)Translational NeurosciencesFaculty of MedicineUniversity of Antwerp Wilrijk 2610 Belgium
- Department of OphthalmologyAntwerp University Hospital Edegem 2650 Belgium
| | - Sandra Van Vlierberghe
- Polymer Chemistry & Biomaterials GroupCentre of Macromolecular Chemistry (CMaC)Department of Organic and Macromolecular ChemistryGhent University Ghent 9000 Belgium
- Brussels PhotonicsDepartment of Applied Physics and PhotonicsVrije Universiteit Brussel and Flanders Make Brussels 1050 Belgium
| | - Bert Van den Bogerd
- Antwerp Research Group for Ocular Science (ARGOS)Translational NeurosciencesFaculty of MedicineUniversity of Antwerp Wilrijk 2610 Belgium
| |
Collapse
|
20
|
Avetisov K, Bakhchieva N, Avetisov S, Novikov I, Frolova A, Akovantseva A, Efremov Y, Kotova S, Timashev P. Biomechanical properties of the lens capsule: A review. J Mech Behav Biomed Mater 2020; 103:103600. [DOI: 10.1016/j.jmbbm.2019.103600] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Revised: 11/26/2019] [Accepted: 12/13/2019] [Indexed: 10/25/2022]
|
21
|
Geraghty B, Abass A, Eliasy A, Jones SW, Rama P, Kassem W, Akhtar R, Elsheikh A. Inflation experiments and inverse finite element modelling of posterior human sclera. J Biomech 2019; 98:109438. [PMID: 31679759 DOI: 10.1016/j.jbiomech.2019.109438] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 10/16/2019] [Accepted: 10/17/2019] [Indexed: 11/30/2022]
Abstract
The complexity of inverse finite element modelling methods used in ocular biomechanics research has significantly increased in recent years in order to produce material parameters that capture microscale tissue behaviour. This study presents a more accessible method for researchers to optimise sclera material parameters for use in finite element studies where macroscale sclera displacements are required. Five human donor sclerae aged between 36 and 72 years were subjected to cycles of internal pressure up to 61 mmHg using a custom-built inflation rig. Displacements were measured using a laser beam and two cameras through a digital image correlation algorithm. Specimen-specific finite element models incorporating regional thickness variation and sclera surface topography were divided into six circumferential regions. An inverse finite element procedure was used to optimise Ogden material parameters for each region. The maximum root mean squared (RMS) error between the numerical and experimental displacements within individual specimens was 17.5 µm. The optimised material parameters indicate a gradual reduction in material stiffness (as measured by the tangent modulus) from the equator to the posterior region at low-stress levels up to 0.005 MPa. The variation in stiffness between adjacent regions became gradually less apparent and statistically insignificant at higher stresses. The study demonstrated how inflation testing combined with inverse modelling could be used to effectively characterise regional material properties capable of reproducing global sclera displacements. The material properties were found to vary between specimens, and it is expected that age could be a contributing factor behind this variation.
Collapse
Affiliation(s)
- Brendan Geraghty
- Department of Musculoskeletal Biology, Institute of Ageing and Chronic Disease, University of Liverpool, L7 8TX, UK.
| | - Ahmed Abass
- School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
| | - Ashkan Eliasy
- School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
| | - Stephen W Jones
- School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
| | - Paolo Rama
- Ophthalmology Department, San Raffaelle Scientific Institute, Milan, Italy
| | - Wael Kassem
- Division of Construction Engineering, Umm Al-Qura University, College of Engineering at Al-Qunfudah, Al-Qunfudah 21912, Saudi Arabia
| | - Riaz Akhtar
- School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
| | - Ahmed Elsheikh
- School of Engineering, University of Liverpool, Liverpool L69 3GH, UK; National Institute for Health Research (NIHR) Biomedical Research Centre at Moorfields, Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, UK; School of Biological Science and Biomedical Engineering, Beihang University, Beijing, China
| |
Collapse
|
22
|
Wang K, Pierscionek BK. Biomechanics of the human lens and accommodative system: Functional relevance to physiological states. Prog Retin Eye Res 2019; 71:114-131. [DOI: 10.1016/j.preteyeres.2018.11.004] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 09/24/2018] [Accepted: 11/07/2018] [Indexed: 12/28/2022]
|
23
|
Blackburn BJ, Jenkins MW, Rollins AM, Dupps WJ. A Review of Structural and Biomechanical Changes in the Cornea in Aging, Disease, and Photochemical Crosslinking. Front Bioeng Biotechnol 2019; 7:66. [PMID: 31019909 PMCID: PMC6459081 DOI: 10.3389/fbioe.2019.00066] [Citation(s) in RCA: 85] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Accepted: 03/07/2019] [Indexed: 12/27/2022] Open
Abstract
The study of corneal biomechanics is motivated by the tight relationship between biomechanical properties and visual function within the ocular system. For instance, variation in collagen fibril alignment and non-enzymatic crosslinks rank high among structural factors which give rise to the cornea's particular shape and ability to properly focus light. Gradation in these and other factors engender biomechanical changes which can be quantified by a wide variety of techniques. This review summarizes what is known about both the changes in corneal structure and associated changes in corneal biomechanical properties in aging, keratoconic, and photochemically crosslinked corneas. In addition, methods for measuring corneal biomechanics are discussed and the topics are related to both clinical studies and biomechanical modeling simulations.
Collapse
Affiliation(s)
- Brecken J. Blackburn
- Cole Eye Institute, Cleveland Clinic, Cleveland, OH, United States
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States
- Department of Ophthalmology, Cleveland Clinic Lerner College of Medicine of CWRU, Cleveland, OH, United States
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
| | - Michael W. Jenkins
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Department of Pediatrics, Case Western Reserve University, Cleveland, OH, United States
| | - Andrew M. Rollins
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
| | - William J. Dupps
- Cole Eye Institute, Cleveland Clinic, Cleveland, OH, United States
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
| |
Collapse
|
24
|
Avetisov KS, Bakhchieva NA, Avetisov SE, Novikov IA, Belikov NV, Khaydukova IV. [Biomechanical properties of the anterior lens capsule after manual and femtolaser capsulotomy]. Vestn Oftalmol 2019; 135:4-11. [PMID: 30830068 DOI: 10.17116/oftalma20191350114] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To comparatively evaluate the mechanical stability of the edge of central fragment of anterior lens capsule after manual and femtolaser capsulotomy. MATERIAL AND METHODS The mechanical tests were performed on the central fragments of the anterior lens capsules obtained intraoperatively after manual and femtolaser capsulotomy (15 and 13 samples, respectively). The conditions of the developed method of mechanical testing are as close to in vivo as possible. The method allows evaluation of the mechanical response mainly from the edge of the sample, reception of the averaged response from the four edges of the capsule, and almost eliminates the effect of additional edge notches in samples obtained by manual capsulotomy. RESULTS After manual capsulotomy, the maximum force and elongation of the anterior capsule sample at maximum tensile strength were significantly higher than similar characteristics of the samples after femtolaser capsulotomy. CONCLUSION The obtained results correspond with the morphological studies of capsule edge structure after manual and femtolaser capsulotomy. The edge of the anterior capsule after femtolaser capsulotomy has form, in rough approximation, close to one of a postage stamp perforation, which is the consequence of micro-irregularities (microfractures) in the areas irradiated by pulsed laser, and wider area of deepithelization compared to the manual technique.
Collapse
Affiliation(s)
- K S Avetisov
- Research Institute of Eye Disease, 11A Rossolimo St., Moscow, Russian Federation, 119021
| | - N A Bakhchieva
- Research Institute of Eye Disease, 11A Rossolimo St., Moscow, Russian Federation, 119021
| | - S E Avetisov
- Research Institute of Eye Disease, 11A Rossolimo St., Moscow, Russian Federation, 119021.,I.M. Sechenov First Moscow State Medical University, Department of Ophthalmology, 8-2 Trubetskaya St., Moscow, Russian Federation, 119991
| | - I A Novikov
- Research Institute of Eye Disease, 11A Rossolimo St., Moscow, Russian Federation, 119021
| | - N V Belikov
- Bauman Moscow State Technical University, 5/1 Baumanskaya 2nd St., 105005
| | - I V Khaydukova
- Bauman Moscow State Technical University, 5/1 Baumanskaya 2nd St., 105005
| |
Collapse
|
25
|
Ma J, Wang Y, Wei P, Jhanji V. Biomechanics and structure of the cornea: implications and association with corneal disorders. Surv Ophthalmol 2018; 63:851-861. [PMID: 29857022 DOI: 10.1016/j.survophthal.2018.05.004] [Citation(s) in RCA: 72] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Revised: 05/17/2018] [Accepted: 05/21/2018] [Indexed: 12/14/2022]
Abstract
Recent studies have shown that alterations in corneal biomechanical properties are associated with corneal pathologies, particularly corneal ectasia. Moreover, these alterations may have implications with regard to the outcomes of therapeutic modalities and corneal refractive surgeries. We address corneal anatomy and its relevance to corneal biomechanical characteristics, as well as ocular and systemic conditions associated with changes in corneal biomechanics.
Collapse
Affiliation(s)
- Jiaonan Ma
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
| | - Yan Wang
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China; Tianjin Eye Hospital, Tianjin Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Naikai University, Tianjin Medical University, Tianjin, China.
| | - Pinghui Wei
- Tianjin Eye Hospital, Tianjin Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Naikai University, Tianjin Medical University, Tianjin, China
| | - Vishal Jhanji
- UPMC Eye Center, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
26
|
Fish Scale-Derived Scaffolds for Culturing Human Corneal Endothelial Cells. Stem Cells Int 2018; 2018:8146834. [PMID: 29853917 PMCID: PMC5949177 DOI: 10.1155/2018/8146834] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Revised: 02/22/2018] [Accepted: 03/19/2018] [Indexed: 11/18/2022] Open
Abstract
Purpose To investigate the biocompatibility of fish scale-derived scaffolds (FSS) with primary human corneal endothelial cells (HCEnCs). Methods HCEnCs were isolated from 30 donor corneas in a donor-matched study and plated in precoated Lab-Tek slides (n = 15) and FSS (n = 15). Cell morphology, proliferation/migration, and glucose uptake were studied (n = 30). Hoechst, ethidium homodimer, and calcein AM (HEC) staining was performed to determine viability and toxicity (n = 6). The cell surface area was calculated based on calcein AM staining. HCEnCs were stained for ZO-1 (n = 6) to detect tight junctions and to measure cell morphology; Ki-67 (n = 6) to measure proliferating cells; and vinculin to quantify focal adhesions (n = 6). The formation of de novo extracellular matrix was analyzed using histology (n = 6). Results HCEnCs attach and grow faster on Lab-Tek slides compared to the undulating topography of the FSS. At day 11, HCEnCs on Lab-Tek slide grew 100% confluent, while FSS was only 65% confluent (p = 0.0883), with no significant difference in glucose uptake between the two (p = 0.5181) (2.2 μg/mL in Lab-Tek versus 2.05 μg/mL in FSS). HEC staining showed no toxicity. The surface area of the cells in Lab-Tek was 409.1 μm2 compared to 452.2 μm2 on FSS, which was not significant (p = 0.5325). ZO-1 showed the presence of tight junctions in both conditions; however, hexagonality was higher (74% in Lab-Tek versus 45% in FSS; p = 0.0006) with significantly less polymorphic cells on Lab-Tek slides (8% in Lab-Tek versus 16% in FSS; p = 0.0041). Proliferative cells were detected in both conditions (4.6% in Lab-Tek versus 4.2% in FSS; p = 0.5922). Vinculin expression was marginally higher in HCEnCs cultured on Lab-Tek (234 versus 199 focal adhesions; p = 0.0507). Histological analysis did not show the formation of a basement membrane. Conclusions HCEnCs cultured on precoated FSS form a monolayer, displaying correct morphology, cytocompatibility, and absence of toxicity. FSS needs further modification in terms of structure and surface chemistry before considering it as a potential carrier for cultured HCEnCs.
Collapse
|
27
|
Loh IP, Fan Gaskin JC, Sherwin T, McGhee CNJ. Extreme Descemet's membrane rupture with hydrops in keratoconus: Clinical and histological manifestations. Am J Ophthalmol Case Rep 2018; 10:271-275. [PMID: 29780950 PMCID: PMC5956727 DOI: 10.1016/j.ajoc.2018.04.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Revised: 03/28/2018] [Accepted: 04/03/2018] [Indexed: 11/24/2022] Open
Abstract
Purpose To study the clinical and histological manifestations of an extreme Descemet's membrane rupture as a result of keratoconus. Observations Using Periodic acid-Schiff assay to study a keratoconic cornea with an extreme rupture showed that the ruptured Descemet's membrane had retracted and folded into scrolls and ridges. The dimensions of the rupture were estimated to be 3.7mm2, and the central cornea was extremely thinned with a thickness of only 260μm. Stromal scarring and loosely packed lamellae were present anterior to the scrolls and ridges. Antibodies targetting the major components of Descemet's membrane, Laminin and type IV collagen, displayed intense labelling adjacent to the scrolls where the stroma was denuded and differential expression patterns lined the ridges. Environmental scanning electron microscopy showed possible collagen deposition at the site of rupture. Conclusions and importance The specific staining patterns of laminin and type IV collagen suggest these components have an important role in re-endothelisation of the cornea. This is the first known report of spatial resolution of the topography of the Descemet's membrane rupture established by environmental scanning electron microscopic image montage.
Collapse
Affiliation(s)
- I-Ping Loh
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Park Road, Auckland, New Zealand
| | - Jennifer C Fan Gaskin
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Park Road, Auckland, New Zealand
| | - Trevor Sherwin
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Park Road, Auckland, New Zealand
| | - Charles N J McGhee
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Park Road, Auckland, New Zealand
| |
Collapse
|
28
|
Avetisov KS, Bakhchieva NA, Avetisov SE, Novikov IA, Belikov NV, Khaydukova IV. [n.s.i.n.i.V. Biomechanical aspects of anterior capsulotomy in cataract surgery]. Vestn Oftalmol 2018; 133:82-88. [PMID: 28745661 DOI: 10.17116/oftalma2017133382-88] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
This paper reviews studies on biomechanical properties of the anterior lens capsule. Early experiments in this field were more fundamental. Later studies were aimed mainly at assessing the mechanical stability of the capsule edge after manual or femtosecond laser capsulorhexis (capsulotomy) - an important step in modern minimally invasive phaco surgery. For biomechanical tests, ex vivo samples of human and animal anterior capsules were used. The results of the studies presented here are quite heterogeneous, which suggests the necessity of gaining further insight into the issue.
Collapse
Affiliation(s)
- K S Avetisov
- Research Institute of Eye Diseases, 11 A, B, Rossolimo St., Moscow, Russia, 119021
| | - N A Bakhchieva
- Research Institute of Eye Diseases, 11 A, B, Rossolimo St., Moscow, Russia, 119021
| | - S E Avetisov
- Research Institute of Eye Diseases, 11 A, B, Rossolimo St., Moscow, Russia, 119021; I.M. Sechenov First Moscow State Medical University, 8/2 Trubetskaya St., Moscow, Russia, 119991
| | - I A Novikov
- Research Institute of Eye Diseases, 11 A, B, Rossolimo St., Moscow, Russia, 119021
| | - N V Belikov
- Bauman Moscow State Technical University, 5/12-aya Baumanskaya, Moscow, Russia, 105005
| | - I V Khaydukova
- Bauman Moscow State Technical University, 5/12-aya Baumanskaya, Moscow, Russia, 105005
| |
Collapse
|
29
|
Weber IP, Rana M, Thomas PBM, Dimov IB, Franze K, Rajan MS. Effect of vital dyes on human corneal endothelium and elasticity of Descemet's membrane. PLoS One 2017; 12:e0184375. [PMID: 28902856 PMCID: PMC5597301 DOI: 10.1371/journal.pone.0184375] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2017] [Accepted: 08/22/2017] [Indexed: 02/03/2023] Open
Abstract
The purpose of this study was to evaluate the effects of vital dyes on human Descemet's membranes (DMs) and endothelia. DMs of 25 human cadaveric corneas with research consent were treated with dyes routinely used in Descemet membrane endothelial keratoplasty (DMEK), 0.05% Trypan blue (TB) or a combination of 0.15% Trypan blue, 0.025% Brilliant blue and 4% Polyethylene glycol (commercial name Membrane Blue Dual; MB). The effects of these two dyes on (i) endothelial cell viability, (ii) DM mechanical properties as assessed by atomic force microscopy, and iii) qualitative DM dye retention were tested for two varying exposure times (one or four minutes). No significant differences in cell toxicity were observed between treatments with TB and MB at the two different exposure times (P = 0.21). Further, both dyes led to a significant increase in DM stiffness: exposure to TB and MB for one minute increased the apparent elastic modulus of the DM by 11.2% (P = 8*10−3) and 17.7%, respectively (P = 4*10−6). A four-minute exposure led to an increase of 8.6% for TB (P = 0.004) and 13.6% for MB (P = 0.03). Finally, at 25 minutes, the dye retention of the DM was considerably better for MB compared to TB. Taken together, a one-minute exposure to MB was found to improve DM visibility compared to TB, with a significant increase in DM stiffness and without detrimental effects on endothelial cell viability. The use of MB could therefore improve (i) visibility of the DM scroll, and (ii) intraoperative unfolding, enhancing the probability of successful DMEK surgery.
Collapse
Affiliation(s)
- Isabell P. Weber
- Department of Physiology, Development and Neuroscience, Anatomy Building, University of Cambridge, Cambridge, United Kingdom
| | - Mrinal Rana
- Department of Ophthalmology, Addenbrookes Hospital, Cambridge University Hospitals NHS Trust, Cambridge, United Kingdom
| | - Peter B. M. Thomas
- Department of Ophthalmology, Addenbrookes Hospital, Cambridge University Hospitals NHS Trust, Cambridge, United Kingdom
| | - Ivan B. Dimov
- Department of Physiology, Development and Neuroscience, Anatomy Building, University of Cambridge, Cambridge, United Kingdom
| | - Kristian Franze
- Department of Physiology, Development and Neuroscience, Anatomy Building, University of Cambridge, Cambridge, United Kingdom
| | - Madhavan S. Rajan
- Department of Ophthalmology, Addenbrookes Hospital, Cambridge University Hospitals NHS Trust, Cambridge, United Kingdom
- Vision and Eye Research Unit (VERU), Anglia Ruskin University, Cambridge, United Kingdom
- * E-mail:
| |
Collapse
|
30
|
Chen J, Li Z, Zhang L, Ou S, Wang Y, He X, Zou D, Jia C, Hu Q, Yang S, Li X, Li J, Wang J, Sun H, Chen Y, Zhu YT, Tseng SCG, Liu Z, Li W. Descemet's Membrane Supports Corneal Endothelial Cell Regeneration in Rabbits. Sci Rep 2017; 7:6983. [PMID: 28765543 PMCID: PMC5539296 DOI: 10.1038/s41598-017-07557-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2015] [Accepted: 06/28/2017] [Indexed: 12/13/2022] Open
Abstract
Descemet’s membrane (DM) helps maintain phenotype and function of corneal endothelial cells under physiological conditions, while little is known about the function of DM in corneal endothelial wound healing process. In the current study, we performed in vivo rabbit corneal endothelial cell (CEC) injury via CEC scraping, in which DM remained intact after CECs removal, or via DM stripping, in which DM was removed together with CECs. We found rabbit corneas in the CEC scraping group healed with transparency restoration, while there was posterior fibrosis tissue formation in the corneas after DM stripping on day 14. Following CEC scraping on day 3, cells that had migrated toward the central cornea underwent a transient fibrotic endothelial-mesenchymal transition (EMT) which was reversed back to an endothelial phenotype on day 14. However, in the corneas injured via DM stripping, most of the cells in the posterior fibrosis tissue did not originate from the corneal endothelium, and they maintained fibroblastic phenotype on day 14. We concluded that corneal endothelial wound healing in rabbits has different outcomes depending upon the presence or absence of Descemet’s membrane. Descemet’s membrane supports corneal endothelial cell regeneration in rabbits after endothelial injury.
Collapse
Affiliation(s)
- Jingyao Chen
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China.,Yan'an Hospital of Kunming Medical University, Kunming, Yunnan, China
| | - Zhiyuan Li
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China.,The Affiliated Hospital of Southern Medicine University in Chenzhou, Chenzhou, Hunan, China
| | - Liying Zhang
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China
| | - Shangkun Ou
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Xiamen University affiliated Xiamen Eye Center, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China
| | - Yanzi Wang
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China
| | - Xin He
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Xiamen University affiliated Xiamen Eye Center, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China
| | - Dulei Zou
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China.,Shandong Eye Hospital, Shandong Eye Institute, Shandong Academy of Medical Sciences, Jinan, Shandong, China
| | - Changkai Jia
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China
| | - Qianqian Hu
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China
| | - Shu Yang
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China
| | - Xian Li
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China
| | - Juan Li
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China
| | - Junqi Wang
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China
| | - Huimin Sun
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China
| | - Yongxiong Chen
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China.,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China
| | | | | | - Zuguo Liu
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China. .,Xiamen University affiliated Xiamen Eye Center, Xiamen, Fujian, China. .,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China.
| | - Wei Li
- Eye Institute of Xiamen University, Xiamen University Medical College, Xiamen, Fujian, China. .,Xiamen University affiliated Xiamen Eye Center, Xiamen, Fujian, China. .,Fujian Provincial Key Laboratory of Ophthalmology and Visual Science, Xiamen, Fujian, China.
| |
Collapse
|
31
|
Hooshmand J, Vote BJ. Femtosecond laser-assisted cataract surgery, technology, outcome, future directions and modern applications. Asia Pac J Ophthalmol (Phila) 2017; 6:393-400. [PMID: 28780777 DOI: 10.22608/apo.2017159] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2017] [Accepted: 07/26/2017] [Indexed: 11/08/2022] Open
Abstract
Since its introduction in 2009 femtosecond laser-assisted cataract surgery (FLACS) has promised to revolutionize cataract surgery. Despite its promise, the assessment of FLACS's perceived benefits has proven to be far more complicated than initially might have been thought. Most studies to date have not provided validation of FLACS technology as a clinically significant advancement on our current techniques. We review FLACS technology and outcomes including detailed analysis of safety, efficacy, cost effectiveness and future prospects using data from the literature and our own published clinical experience.
Collapse
Affiliation(s)
| | - Brendan J Vote
- Tasmanian Eye Institute, South Launceston, Tasmania, Australia
- University of Tasmania, Hobart, Tasmania, Australia
| |
Collapse
|
32
|
Schwarz C, Aldrich BT, Burckart KA, Schmidt GA, Zimmerman MB, Reed CR, Greiner MA, Sander EA. Descemet membrane adhesion strength is greater in diabetics with advanced disease compared to healthy donor corneas. Exp Eye Res 2016; 153:152-158. [PMID: 27777123 DOI: 10.1016/j.exer.2016.10.015] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2016] [Revised: 10/19/2016] [Accepted: 10/20/2016] [Indexed: 11/27/2022]
Abstract
Descemet membrane endothelial keratoplasty (DMEK) is an increasingly popular surgical procedure for treating ocular diseases that require a corneal transplant. Previous studies have found that tissue tearing during surgical preparation is more likely elevated in eyes from donors with a history of diabetes mellitus. To quantify these potential differences, we established an experimental technique for quantifying the force required to separate the endothelium-Descemet membrane complex (EDM) from stroma in human donor corneal tissue, and we assessed differences in adhesion strength between diabetic and non-diabetic donor corneas. Transplant suitable corneas were obtained from 23 donors 50-75 years old with an average preservation to assay time of 11.5 days. Corneas were classified from a medical records review as non-diabetic (ND, n = 9), diabetic without evidence of advanced disease (NAD, n = 8), or diabetic with evidence of advanced disease (AD, n = 10). Corneas were sectioned into 3 mm wide strips and the EDM peeled from the stroma. Using the force-extension data obtained from mechanical peel testing, EDM elastic peel tension (TE), elastic stiffness (SE), average delamination tension (TD), and maximum tension (TMAX) were calculated. Mean TE, SE, TD, and TMAX values for ND corneas were 0.78 ± 0.07 mN/mm, 0.37 ± 0.05 mN/mm/mm, 0.78 ± 0.08 mN/mm, and 0.94 ± 0.17 mN/mm, respectively. NAD values did not differ significantly. However, AD values for TE (1.01 ± 0.18 mN/mm), TD (1.09 ± 0.21 mN/mm), and TMAX (1.37 ± 0.24 mN/mm) were greater than ND and NAD corneas (P < 0.05). SE did not differ significantly between groups. These findings provide proof of the concept that chronic hyperglycemia from diabetes mellitus results in a phenotypically more adhesive interface between Descemet membrane and the posterior stroma in donor corneal tissue. Results of this study provide a foundation for further investigations into the impact of diabetes on the posterior cornea, eye banking, and keratoplasty.
Collapse
Affiliation(s)
- Chaid Schwarz
- Department of Biomedical Engineering, University of Iowa, Iowa City, IA, USA
| | - Benjamin T Aldrich
- Department of Ophthalmology and Visual Sciences, University of Iowa Carver College of Medicine, Iowa City, IA, USA; Iowa Lions Eye Bank, Coralville, IA, USA
| | | | | | - M Bridget Zimmerman
- College of Public Health, Department of Biostatistics, University of Iowa, Iowa City, IA, USA
| | | | - Mark A Greiner
- Department of Ophthalmology and Visual Sciences, University of Iowa Carver College of Medicine, Iowa City, IA, USA; Iowa Lions Eye Bank, Coralville, IA, USA; Cornea Research Center, Stephen A. Wynn Institute for Vision Research, Iowa City, IA, USA.
| | - Edward A Sander
- Department of Biomedical Engineering, University of Iowa, Iowa City, IA, USA.
| |
Collapse
|
33
|
Abstract
PURPOSE To evaluate the effect of trypan blue on the elastic property of Descemet membrane (DM) by atomic force microscopy. METHODS Human corneas (n = 10) were obtained from the Illinois Eye Bank (Chicago, IL). The DM was isolated and divided into two halves, one half was stained with ophthalmic trypan blue (Vision Blue, 0.06%, DORC International), whereas the unstained other half served as control. The DM samples were then tested using the atomic force microscope. Data were analyzed using the Hertz model for the evaluation of the Young modulus of elasticity. RESULTS Atomic force microscopy showed higher cantilever deflection on trypan blue-stained DM compared with control, and the difference was statistically significant (P = 0.03). Force-distance curve analysis also revealed a statistically significant increase in the Young modulus of elasticity in the trypan blue-stained samples (10.5 ± 1.4 kPa) compared with the control (5.8 ± 0.8 kPa), (P < 0.0001). CONCLUSIONS Our results suggest that trypan blue may decrease DM elasticity and consequently increase its stiffness. This may influence the graft adherence when used for endothelial keratoplasty.
Collapse
|
34
|
Ali M, Raghunathan V, Li JY, Murphy CJ, Thomasy SM. Biomechanical relationships between the corneal endothelium and Descemet's membrane. Exp Eye Res 2016; 152:57-70. [PMID: 27639516 DOI: 10.1016/j.exer.2016.09.004] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Accepted: 09/13/2016] [Indexed: 12/28/2022]
Abstract
The posterior face of the cornea consists of the corneal endothelium, a monolayer of cuboidal cells that secrete and attach to Descemet's membrane, an exaggerated basement membrane. Dysfunction of the endothelium compromises the barrier and pump functions of this layer that maintain corneal deturgesence. A large number of corneal endothelial dystrophies feature irregularities in Descemet's membrane, suggesting that cells create and respond to the biophysical signals offered by their underlying matrix. This review provides an overview of the bidirectional relationship between Descemet's membrane and the corneal endothelium. Several experimental methods have characterized a richly topographic and compliant biophysical microenvironment presented by the posterior surface of Descemet's membrane, as well as the ultrastructure and composition of the membrane as it builds during a lifetime. We highlight the signaling pathways involved in the mechanotransduction of biophysical cues that influence cell behavior. We present the specific example of Fuchs' corneal endothelial dystrophy as a condition in which a dysregulated Descemet's membrane may influence the progression of disease. Finally, we discuss some disease models and regenerative strategies that may facilitate improved treatments for corneal dystrophies.
Collapse
Affiliation(s)
- Maryam Ali
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, CA, 95616, USA.
| | - VijayKrishna Raghunathan
- The Ocular Surface Institute, College of Optometry, University of Houston, Houston, TX, 77204, USA.
| | - Jennifer Y Li
- Department of Ophthalmology & Vision Science, School of Medicine, UC Davis Medical Center, Sacramento, CA, 95817, USA.
| | - Christopher J Murphy
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, CA, 95616, USA; Department of Ophthalmology & Vision Science, School of Medicine, UC Davis Medical Center, Sacramento, CA, 95817, USA.
| | - Sara M Thomasy
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, CA, 95616, USA.
| |
Collapse
|
35
|
Corneal Descemet's membrane rupture in a patient sustaining high-pressure water jet injury. Can J Ophthalmol 2015; 50:e35-6. [PMID: 26040228 DOI: 10.1016/j.jcjo.2015.02.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2014] [Revised: 09/05/2014] [Accepted: 02/03/2015] [Indexed: 11/21/2022]
|
36
|
Chen J, Yan C, Zhu M, Yao Q, Shao C, Lu W, Wang J, Mo X, Gu P, Fu Y, Fan X. Electrospun nanofibrous SF/P(LLA-CL) membrane: a potential substratum for endothelial keratoplasty. Int J Nanomedicine 2015; 10:3337-50. [PMID: 26005345 PMCID: PMC4427599 DOI: 10.2147/ijn.s77706] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Background Cornea transplant technology has progressed markedly in recent decades, allowing surgeons to replace diseased corneal endothelium by a thin lamellar structure. A thin, transparent, biocompatible, tissue-engineered substratum with corneal endothelial cells for endothelial keratoplasty is currently of interest. Electrospinning a nanofibrous structure can simulate the extracellular matrix and have beneficial effects for cell culture. Silk fibroin (SF) has good biocompatibility but poor mechanical properties, while poly(l-lactic acid-co-ε-caprolactone) (P(LLA-CL)) has good mechanical properties but poor biocompatibility. Blending SF with P(LLA-CL) can maintain the advantages of both these materials and overcome their disadvantages. Blended electrospun nanofibrous membranes may be suitable for regeneration of the corneal endothelium. The aim of this study was to produce a tissue-engineered construct suitable for endothelial keratoplasty. Methods Five scaffolds containing different SF:P(LLA-CL) blended ratios (100:0, 75:25, 50:50, 25:75, 0:100) were manufactured. A human corneal endothelial (B4G12) cell line was cultured on the membranes. Light transmission, speed of cell adherence, cell viability (live-dead test), cell proliferation (Ki-67, BrdU staining), and cell monolayer formation were detected on membranes with the different blended ratios, and expression of some functional genes was also detected by real-time polymerase chain reaction. Results Different blended ratios of scaffolds had different light transmittance properties. The 25:75 blended ratio membrane had the best transmittance among these scaffolds. All electrospun nanofibrous membranes showed improved speed of cell adherence when compared with the control group, especially when the P(LLA-CL) ratio increased. The 25:75 blended ratio membranes also had the highest cell proliferation. B4G12 cells could form a monolayer on all scaffolds, and most functional genes were also stably expressed on all scaffolds. Only two genes showed changes in expression. Conclusion All blended ratios of SF:P(LLA-CL) scaffolds were evaluated and showed good biocompatibility for cell adherence and monolayer formation. Among them, the 25:75 blended ratio SF:P(LLA-CL) scaffold had the best transmittance and the highest cell proliferation. These attributes further the potential application of the SF:P(LLA-CL) scaffold for corneal endothelial transplantation.
Collapse
Affiliation(s)
- Junzhao Chen
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Chenxi Yan
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Mengyu Zhu
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Qinke Yao
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Chunyi Shao
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Wenjuan Lu
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Jing Wang
- Biomaterials and Tissue Engineering Laboratory, College of Chemistry and Chemical Engineering and Biotechnology, Donghua University, Shanghai, People's Republic of China
| | - Xiumei Mo
- Biomaterials and Tissue Engineering Laboratory, College of Chemistry and Chemical Engineering and Biotechnology, Donghua University, Shanghai, People's Republic of China
| | - Ping Gu
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Yao Fu
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Xianqun Fan
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| |
Collapse
|
37
|
DIAO YUMEI, HONG JING. Feasibility and safety of porcine Descemet’s membrane as a carrier for generating tissue-engineered corneal endothelium. Mol Med Rep 2015; 12:1929-34. [DOI: 10.3892/mmr.2015.3665] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Accepted: 12/02/2014] [Indexed: 11/06/2022] Open
|
38
|
Ozcelik B, Brown KD, Blencowe A, Ladewig K, Stevens GW, Scheerlinck JPY, Abberton K, Daniell M, Qiao GG. Biodegradable and biocompatible poly(ethylene glycol)-based hydrogel films for the regeneration of corneal endothelium. Adv Healthc Mater 2014; 3:1496-507. [PMID: 24652807 DOI: 10.1002/adhm.201400045] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2014] [Indexed: 12/16/2022]
Abstract
Corneal endothelial cells (CECs) are responsible for maintaining the transparency of the human cornea. Loss of CECs results in blindness, requiring corneal transplantation. In this study, fabrication of biocompatible and biodegradable poly(ethylene glycol) (PEG)-based hydrogel films (PHFs) for the regeneration and transplantation of CECs is described. The 50-μm thin hydrogel films have similar or greater tensile strengths to human corneal tissue. Light transmission studies reveal that the films are >98% optically transparent, while in vitro degradation studies demonstrate their biodegradation characteristics. Cell culture studies demonstrate the regeneration of sheep corneal endothelium on the PHFs. Although sheep CECs do not regenerate in vivo, these cells proliferate on the films with natural morphology and become 100% confluent within 7 d. Implantation of the PHFs into live sheep corneas demonstrates the robustness of the films for surgical purposes. Regular slit lamp examinations and histology of the cornea after 28 d following surgery reveal minimal inflammatory responses and no toxicity, indicating that the films are benign. The results of this study suggest that PHFs are excellent candidates as platforms for the regeneration and transplantation of CECs as a result of their favorable biocompatibility, degradability, mechanical, and optical properties.
Collapse
Affiliation(s)
- Berkay Ozcelik
- Department of Chemical and Biomolecular Engineering; The University of Melbourne; Victoria 3010 Australia
| | - Karl D. Brown
- Centre for Eye Research Australia (CERA); Royal Victorian Eye & Ear Hospital, Peter Howson Wing; Victoria 3002 Australia
| | - Anton Blencowe
- Department of Chemical and Biomolecular Engineering; The University of Melbourne; Victoria 3010 Australia
| | - Katharina Ladewig
- Department of Chemical and Biomolecular Engineering; The University of Melbourne; Victoria 3010 Australia
| | - Geoffrey W. Stevens
- Department of Chemical and Biomolecular Engineering; The University of Melbourne; Victoria 3010 Australia
| | | | - Keren Abberton
- O'Brien Institute; Fitzroy St, Fitzroy Victoria 3065 Australia
- Faculty of Health Sciences, Australian Catholic University; Melbourne Australia
- Department of Surgery; St. Vincent's Hospital; Fitzroy St Fitzroy Victoria 3065 Australia
| | - Mark Daniell
- Centre for Eye Research Australia (CERA); Royal Victorian Eye & Ear Hospital, Peter Howson Wing; Victoria 3002 Australia
| | - Greg G. Qiao
- Department of Chemical and Biomolecular Engineering; The University of Melbourne; Victoria 3010 Australia
| |
Collapse
|
39
|
Koo S, Muhammad R, Peh GS, Mehta JS, Yim EK. Micro- and nanotopography with extracellular matrix coating modulate human corneal endothelial cell behavior. Acta Biomater 2014; 10:1975-84. [PMID: 24456758 DOI: 10.1016/j.actbio.2014.01.015] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2013] [Revised: 01/03/2014] [Accepted: 01/13/2014] [Indexed: 12/13/2022]
Abstract
The human corneal endothelium plays an important role in maintaining corneal transparency. Human corneal endothelial cells have limited regenerative capability in vivo. Consequently, endothelial dysfunction can occur following corneal endothelial trauma or inherited diseases. To restore endothelial function, corneal transplantation is needed. However, there is a worldwide shortage of donor corneas, motivating the development of a tissue-engineered graft alternative using cultivated endothelial cells. To induce in vitro cell proliferation, much effort has been made to improve culture conditions and to mimic the native extracellular microenvironment. We incorporated topographical and biochemical cues in our in vitro culture of human corneal endothelial cell line B4G12 (HCEC-B4G12) and hypothesized that manipulation of the extracellular environment can modulate cell proliferation, morphometry and phenotype. The topographies tested were nanopillars, microwells and micropillars on polydimethylsiloxane, while the biochemical factors were extracellular matrix protein coatings of fibronectin-collagen I (FC), FNC® coating mix (FNC) and laminin-chondroitin sulfate (LC). Cellular morphometry, Na(+)/K(+)-ATPase and zona occludens 1 (ZO-1) gene and protein expression were analyzed 3days after cells had formed a confluent monolayer. The cell circularity on all patterns and coatings was above 0.78. On all coatings, cell area was the lowest on micropillars. The coefficient of variation (CV) of the cell area was the lowest on nanopillars with an LC coating. With an FC coating, micropillars induced a better cellular outcome as the cells had the greatest circularity, smallest cell area and highest Na(+)/K(+)-ATPase and ZO-1 gene and protein expression. With the LC coating, HCECs grown on nanopillars resulted in the lowest CV of the cell area and the highest ZO-1 gene expression. Thus, HCEC-B4G12 morphometry and phenotype can be improved using different topographical and biochemical cues.
Collapse
|
40
|
Hugar DL, Ivanisevic A. Materials characterization and mechanobiology of the eye. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2013; 33:1867-75. [PMID: 23498207 DOI: 10.1016/j.msec.2013.02.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2012] [Revised: 01/07/2013] [Accepted: 02/05/2013] [Indexed: 12/29/2022]
Abstract
The eye responds to a great deal of internal and external stimuli throughout its normal function. Due to this, a mechanical or chemical analysis alone is insufficient. A systematic materials characterization is needed. A mechanobiological approach is required for a full understanding of the unique properties and function of the eye. This review compiles the mechanical properties of select eye components, summarizes mechanical and chemical testing platforms, and overviews modeling approaches. Analysis is done across studies, experimental methods, and between species in order to summarize what is known about the mechanobiology of the eye. Several opportunities for future research are identified.
Collapse
Affiliation(s)
- Daniel L Hugar
- Department of Materials Science and Engineering, North Carolina State University, Raleigh, NC 27695, USA
| | | |
Collapse
|
41
|
Geraghty B, Jones SW, Rama P, Akhtar R, Elsheikh A. Age-related variations in the biomechanical properties of human sclera. J Mech Behav Biomed Mater 2012. [PMID: 23182387 DOI: 10.1016/j.jmbbm.2012.10.011] [Citation(s) in RCA: 82] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
This study examined age-related changes in biomechanical behaviour in the anterior, equatorial and posterior regions of the human sclera (white of the eye). Circumferential strip specimens were extracted from areas close to the limbus, equator and posterior pole in 45 donor scleras ranging in age between 51 and 84 years. The strips were subjected to cycles of uniaxial tension loading at a strain rate of 8% per minute while monitoring their load-deformation behaviour. All specimens demonstrated nonlinear behaviour with an initially low tangent modulus (a measure of material stiffness) increasing under higher stresses. The average ratios between the tangent modulus at a high stress of 1 MPa and that at a low stress of 0.05 MPa were 11.2±1.7, 12.0±1.7 and 12.4±1.5 for anterior, equatorial and posterior specimens, respectively. Stiffening was observed with age in all regions, but it was statistically significant only in the anterior region (P<0.01). Anterior specimens showed the largest stiffness growth with advancing age in both the initial, matrix regulated phase of behaviour (0.32 MPa/decade), and the final, collagen regulated phase (3.97 MPa/decade), followed by equatorial (0.27 and 2.15 MPa/decade) then posterior specimens (0.14 and 0.26 MPa/decade). The stress-strain behaviour of scleral tissue exhibits increasing stiffness with higher age. In addition to a regional variation of material stiffness, the rate of stiffness growth with age also varies between regions.
Collapse
Affiliation(s)
- Brendan Geraghty
- Division of Civil Engineering, University of Dundee, Nethergate, Dundee, Tayside DD1 4HN, UK
| | | | | | | | | |
Collapse
|
42
|
Petsche SJ, Chernyak D, Martiz J, Levenston ME, Pinsky PM. Depth-dependent transverse shear properties of the human corneal stroma. Invest Ophthalmol Vis Sci 2012; 53:873-80. [PMID: 22205608 DOI: 10.1167/iovs.11-8611] [Citation(s) in RCA: 87] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To measure the transverse shear modulus of the human corneal stroma and its profile through the depth by mechanical testing, and to assess the validity of the hypothesis that the shear modulus will be greater in the anterior third due to increased interweaving of lamellae. METHODS Torsional rheometry was used to measure the transverse shear properties of 6 mm diameter buttons of matched human cadaver cornea pairs. One cornea from each pair was cut into thirds through the thickness with a femtosecond laser and each stromal third was tested individually. The remaining intact corneas were tested to measure full stroma shear modulus. The shear modulus from a 1% shear strain oscillatory test was measured at various levels of axial compression for all samples. RESULTS After controlling for axial compression, the transverse shear moduli of isolated anterior layers were significantly higher than central and posterior layers. Mean modulus values at 0% axial strain were 7.71 ± 6.34 kPa in the anterior, 1.99 ± 0.45 kPa in the center, 1.31 ± 1.01 kPa in the posterior, and 9.48 ± 2.92 kPa for full thickness samples. A mean equilibrium compressive modulus of 38.7 ± 8.6 kPa at 0% axial strain was calculated from axial compression measured during the shear tests. CONCLUSIONS Transverse shear moduli are two to three orders of magnitude lower than tensile moduli reported in the literature. The profile of shear moduli through the depth displayed a significant increase from posterior to anterior. This gradient supports the hypothesis and corresponds to the gradient of interwoven lamellae seen in imaging of stromal cross-sections.
Collapse
Affiliation(s)
- Steven J Petsche
- Department of Mechanical Engineering, Stanford University, Stanford, California, USA
| | | | | | | | | |
Collapse
|
43
|
Characterization of the Cleavage Plane in Descemet's Membrane Endothelial Keratoplasty. Ophthalmology 2011; 118:1950-7. [DOI: 10.1016/j.ophtha.2011.03.025] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2010] [Revised: 03/15/2011] [Accepted: 03/15/2011] [Indexed: 11/17/2022] Open
|
44
|
Human corneal endothelial cell growth on a silk fibroin membrane. Biomaterials 2011; 32:4076-84. [DOI: 10.1016/j.biomaterials.2010.12.034] [Citation(s) in RCA: 128] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2010] [Accepted: 12/24/2010] [Indexed: 12/13/2022]
|
45
|
Primate lens capsule elasticity assessed using Atomic Force Microscopy. Exp Eye Res 2011; 92:490-4. [PMID: 21420953 DOI: 10.1016/j.exer.2011.03.008] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2010] [Revised: 03/01/2011] [Accepted: 03/11/2011] [Indexed: 11/22/2022]
Abstract
The purpose of this project is to measure the elasticity of the human and non-human primate lens capsule at the microscopic scale using Atomic Force Microscopy (AFM). Elasticity measurements were performed using AFM on the excised anterior lens capsule from 9 cynomolgus monkey (5.9-8.0 years), 8 hamadryas baboon (2.8-10.1 years), and 18 human lenses (33-79 years). Anterior capsule specimens were obtained by performing a 5 mm continuous curvilinear capsulorhexis and collecting the resulting disk of capsular tissue. To remove the lens epithelial cells the specimen was soaked in 0.1% trypsin and 0.02% EDTA for 5 min, washed, and placed on a Petri dish and immersed in DMEM. Elasticity measurements of the capsule were performed with a laboratory-built AFM system custom designed for force measurements of ophthalmic tissues. The capsular specimens were probed with an AFM cantilever tip to produce force-indentation curves for each specimen. Young's modulus was calculated from the force-indentation curves using the model of Sneddon for a conical indenter. Young's modulus of elasticity was 20.1-131 kPa for the human lens capsule, 9.19-117 kPa for the cynomolgus lens capsule, and 13.1-62.4 kPa for the baboon lens capsule. Young's modulus increased significantly with age in humans (p = 0.03). The age range of the monkey and baboon samples was not sufficient to justify an analysis of age dependence. The capsule elasticity of young humans (<45 years) was not statistically different from that of the monkey and baboon. In humans, there is an increase in lens capsule stiffness at the microscale that could be responsible for an increase in lens capsule bulk stiffness.
Collapse
|
46
|
Powell TA, Amini R, Oltean A, Barnett VA, Dorfman KD, Segal Y, Barocas VH. Elasticity of the porcine lens capsule as measured by osmotic swelling. J Biomech Eng 2011; 132:091008. [PMID: 20815642 DOI: 10.1115/1.4002024] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
As an alternative to purely mechanical methods, optical tracking of passive osmotic swelling was used to assess mechanical properties of the porcine lens capsule. A simple model was developed accounting for the permeability of the lens fiber cells and capsule to water, the concentration of fixed charges in the fiber cells, and the capsule's resistance to the swelling of fiber cells. Fitting the model solution to experimental data provided an estimate of the elastic modulus of the lens capsule under the assumption of linear isotropic elasticity. The calculated elastic modulus at a fixed charge density of 20 mol m(-3) was 2.0+/-0.5 MPa (mean+/-95% confidence interval; n=15) for 0.1% saline solution, 0.64+/-0.3 MPa (n=10) for 0.2% saline solution, and 0.28+/-0.5 MPa (n=6) for 0.5% saline solution. These values are comparable to previously reported moduli of elasticity for the porcine lens capsule at small strains (<10%), and the slight increase with hypotonicity is consistent with the nonlinear mechanical behavior of the lens capsule. Although limited by being a single measurement on a heterogeneous tissue, osmotic swelling provides a quantitative assessment of the stiffness of the lens capsule without requiring dissection or manipulation of the lens. Thus, the new method could be useful for small animal models.
Collapse
Affiliation(s)
- Tracy A Powell
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN 55455, USA
| | | | | | | | | | | | | |
Collapse
|
47
|
Elsheikh A, Geraghty B, Rama P, Campanelli M, Meek KM. Characterization of age-related variation in corneal biomechanical properties. J R Soc Interface 2010; 7:1475-85. [PMID: 20392712 PMCID: PMC2935603 DOI: 10.1098/rsif.2010.0108] [Citation(s) in RCA: 130] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2010] [Accepted: 03/24/2010] [Indexed: 11/12/2022] Open
Abstract
An experimental study has been conducted to determine the stress-strain behaviour of human corneal tissue and how the behaviour varies with age. Fifty-seven well-preserved ex vivo donor corneas aged between 30 and 99 years were subjected to cycles of posterior pressure up to 60 mm Hg while monitoring their behaviour. The corneas were mechanically clamped along their ring of scleral tissue and kept in physiological conditions of temperature and hydration. The tissue demonstrated hyper-elastic pressure-deformation and stress-strain behaviour that closely matched an exponential trend. Clear stiffening (increased resistance to deformation) with age was observed in all loading cycles, and the rate of stiffness growth was nonlinear with bias towards older specimens. With a strong statistical association between stiffness and age (p < 0.05), it was possible to develop generic stress-strain equations that were suitable for all ages between 30 and 99 years. These equations, which closely matched the experimental results, depicted corneal stiffening with age in a form suitable for implementation in numerical simulations of ocular biomechanical behaviour.
Collapse
Affiliation(s)
- Ahmed Elsheikh
- Division of Civil Engineering, University of Dundee, Dundee DD1 4HN, UK.
| | | | | | | | | |
Collapse
|
48
|
Huh MIL, Kim YH, Park JH, Bae SW, Kim MH, Chang Y, Kim SJ, Lee SR, Lee YS, Jin EJ, Sonn JK, Kang SS, Jung JC. Distribution of TGF-β isoforms and signaling intermediates in corneal fibrotic wound repair. J Cell Biochem 2009; 108:476-88. [DOI: 10.1002/jcb.22277] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
49
|
Burd HJ. A structural constitutive model for the human lens capsule. Biomech Model Mechanobiol 2008; 8:217-31. [PMID: 18622755 DOI: 10.1007/s10237-008-0130-5] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2008] [Accepted: 06/17/2008] [Indexed: 10/21/2022]
Abstract
Published data on the mechanical performance of the human lens capsule when tested under uniaxial and biaxial conditions are reviewed. It is concluded that two simple phenomenological constitutive models (namely a linear elastic model and a Fung-type hyperelastic model) are unable to provide satisfactory representations of the mechanical behaviour of the capsule for both of these loading conditions. The possibility of resolving these difficulties using a structural constitutive model for the capsule, of a form that is inspired by the network of collagen IV filaments that exist within the lens capsule, is explored. The model is implemented within a rectangular periodic cell. Prescribed stretches are imposed on the periodic cell and the network is allowed to deform in a non-affine manner. The performance of the constitutive model correlates well with previously published test data. One possible application of the model is in the development of a multi-scale analysis of the mechanics of the human lens capsule.
Collapse
Affiliation(s)
- Harvey John Burd
- Department of Engineering Science, Oxford University, Oxford, OX1 3PJ, UK.
| |
Collapse
|
50
|
Ziebarth NM, Borja D, Arrieta E, Aly M, Manns F, Dortonne I, Nankivil D, Jain R, Parel JM. Role of the lens capsule on the mechanical accommodative response in a lens stretcher. Invest Ophthalmol Vis Sci 2008; 49:4490-6. [PMID: 18515568 DOI: 10.1167/iovs.07-1647] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To determine whether changes in elastic properties of the lens capsule ex vivo with age contribute to the forces necessary for accommodation. METHODS Postmortem human (n = 22; age average: 41 +/- 17 years; range: 6-7) and cynomolgus monkey (n = 19; age average: 7.7 +/- 1.8 years, range: 4.2-10) tissues including the lens, capsule, zonules, ciliary body, and sclera were mounted in an optomechanical lens-stretching system. Starting at 0 load, the sclera was symmetrically stretched to 2 mm in 0.25-mm steps at a speed of 0.1 mm x s(-1). The load and lens diameter were measured at each step. The lens contents were removed through a mini-capsulorhexis. The stretching cycles were repeated on the empty capsular bag. The forces necessary to stretch the natural lens and empty bag were quantified as a function of age and compared. RESULTS The force needed to stretch the empty lens capsule was independent of age (human, 2.6-34.9 g/mm [25.2-342.7 mN/mm]; monkey, 8.2-21.3 g/mm [80.3-208.6 mN/mm]). The ratio of the force necessary to stretch the empty lens capsule to the force necessary to stretch the natural lens decreased with age in the human and monkey lenses (P = 0.003, P = 0.72, respectively). CONCLUSIONS The mechanical properties of the empty lens capsule assessed ex vivo in a lens stretcher remain constant with age, suggesting that the changes in elasticity of the lens capsule do not play a significant role in presbyopia. In young eyes, the lens capsule determines the force necessary to stretch the whole lens. The age-related increase in force needed to stretch the lens is due to changes in the lens contents.
Collapse
Affiliation(s)
- Noël M Ziebarth
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida 33136, USA
| | | | | | | | | | | | | | | | | |
Collapse
|