1
|
Emu ME, Hatami-Marbini H. Planar biaxial testing of CXL strengthening effects. Exp Eye Res 2024; 246:110005. [PMID: 39032624 DOI: 10.1016/j.exer.2024.110005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 06/07/2024] [Accepted: 07/12/2024] [Indexed: 07/23/2024]
Abstract
The stiffening effect of corneal crosslinking (CXL) treatment, a therapeutic approach for managing the progression of keratoconus, has been primarily investigated using uniaxial tensile experiments. However, this testing technique has several drawbacks and is unable to measure the mechanical response of cornea under a multiaxial loading state. In this work, we used biaxial mechanical testing method to characterize biomechanical properties of porcine cornea before and after CXL treatment. We also investigated the influence of preconditioning on measured properties and used TEM images to determine microstructural characteristics of the extracellular matrix. The conventional method of CXL treatment was used for crosslinking the porcine cornea. The biaxial experiments were done by an ElectroForce TestBench system at a stretch ratio of 1:1 and a displacement rate of 2 mm/min with and without preconditioning. The experimental measurements showed no significant difference in the mechanical properties of porcine cornea along the nasal temporal (NT) and superior inferior (SI) direction. Furthermore, the CXL therapy significantly enhanced the mechanical properties along both directions without creating anisotropic response. The samples tested with preconditioning showed significantly stiffer response than those tested without preconditioning. The TEM images showed that the CXL therapy did not increase the diameter of collagen fibers but significantly decreased their interfibrillar spacing, consistent with the mechanical property improvement of CXL treated samples.
Collapse
Affiliation(s)
- Md Esharuzzaman Emu
- Mechanical and Industrial Engineering Department, University of Illinois Chicago, Chicago, IL, USA
| | - Hamed Hatami-Marbini
- Mechanical and Industrial Engineering Department, University of Illinois Chicago, Chicago, IL, USA.
| |
Collapse
|
2
|
Hatami-Marbini H, Emu ME. The relationship between keratan sulfate glycosaminoglycan density and mechanical stiffening of CXL treatment. Exp Eye Res 2023; 234:109570. [PMID: 37454921 PMCID: PMC10530321 DOI: 10.1016/j.exer.2023.109570] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 06/20/2023] [Accepted: 07/06/2023] [Indexed: 07/18/2023]
Abstract
The corneal stroma is primarily composed of collagen fibrils, proteoglycans, and glycosaminoglycans (GAGs). It is known that corneal crosslinking (CXL) treatment improves mechanical properties of the cornea. However, the influence of stromal composition on the strengthening effect of CXL procedure has not been thoroughly investigated. The primary objective of the present research was to characterize the effect of keratan sulfate (KS) GAGs on the efficacy of CXL therapy. To this end, the CXL method was used to crosslink porcine corneal samples from which KS GAGs were enzymatically removed by keratanase II enzyme. Alcian blue staining was done to confirm the successful digestion of GAGs and uniaxial tensile experiments were performed for characterizing corneal mechanical properties. The influence of GAG removal and CXL treatment on resistance of corneal samples against enzymatic pepsin degradation was also quantified. It was found that removal of KS GAGs significantly softened corneal tensile properties (P < 0.05). Moreover, the CXL therapy significantly increased the tensile stiffness of GAG-depleted strips (P < 0.05). GAG-depleted corneal buttons were dissolved in the pepsin digestion solution significantly faster than control samples (P < 0.05). The CXL treatment significantly increased the time needed for complete pepsin digestion of GAG-depleted disks (P < 0.05). Based on these observations, we concluded that KS GAGs play a significant role in defining tensile properties and structural integrity of porcine cornea. Furthermore, the stiffening influence of the CXL treatment does not significantly depend on the density of corneal KS GAGs. The findings of the present study provided new information on the relation between corneal composition and CXL procedure mechanical effects.
Collapse
Affiliation(s)
- H Hatami-Marbini
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering, Department, University of Illinois Chicago, Chicago, IL, USA.
| | - Md E Emu
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering, Department, University of Illinois Chicago, Chicago, IL, USA
| |
Collapse
|
3
|
Chen L, Huang Y, Zhang X, Shi Y, Gao Z, Sun B, Shen Y, Sun L, Cao Y, Zhang Q, Guo J, Li F, Chen W, Li X, Zhou X. Corneal Biomechanical Properties Demonstrate Anisotropy and Correlate With Axial Length in Myopic Eyes. Invest Ophthalmol Vis Sci 2023; 64:27. [PMID: 37477932 PMCID: PMC10365135 DOI: 10.1167/iovs.64.10.27] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 06/12/2023] [Indexed: 07/22/2023] Open
Abstract
Purpose The purpose of this study was to investigate the ex vivo and in vivo biomechanical characteristic of cornea in myopic eyes. Methods Fifty-one corneal stromal lenticules were obtained from myopic eyes during the SMILE procedure and were tested by a biaxial tensile system within 24 hours postoperatively. The material properties of the lenticules were described using stress-strain curves and were compared among axial length (AL) <26 mm and AL ≥ 26 mm group. Pre-operative stress-strain index (SSI) parameters were used to evaluate the biomechanical properties of the cornea in vivo. Results Compared with AL < 26 mm, the tangent modulus significantly decreased in horizontal and vertical directions when AL ≥ 26 mm (P < 0.05); SSI also significantly decreased when AL ≥ 26 mm (P < 0.05). Anisotropic parameter is positively correlated with AL (r = 0.307, P < 0.05). Compared with AL < 26 mm, anisotropic parameter significantly increased when AL ≥ 26 mm (P < 0.05). SSI was negatively correlated with AL (r = -0.380, P < 0.05) in the AL < 26 mm group but not in the AL ≥ 26 mm group (P > 0.05). Compared with 26 mm ≤ AL < 27 mm group, the tangent modulus significantly decreased in the horizontal direction (P < 0.05) but not in the vertical direction when 27 mm ≤ AL < 28 mm (P > 0.05). Conclusions The biomechanical properties of cornea decreased with the increase of AL. Tangent modulus significantly decreased in the horizontal direction compared with vertical direction. AL should be taken into account during calculation of corneal biomechanical parameters in order to improve validity.
Collapse
Affiliation(s)
- Lingfeng Chen
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Yangyi Huang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Xiaoyu Zhang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yike Shi
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Zhipeng Gao
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Bingqing Sun
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yang Shen
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Ling Sun
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yifan Cao
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Qianqian Zhang
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, China
- School of Automation and Software Engineering, Shanxi University, Taiyuan, Shanxi, China
| | - Jiqiang Guo
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, China
| | - Fen Li
- College of Mechanical and Vehicle Engineering, Taiyuan University of Technology, Taiyuan, China
- Institute of Applied Mechanics, Taiyuan University of Technology, Taiyuan, China
| | - Weiyi Chen
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Xiaona Li
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| |
Collapse
|
4
|
Makuloluwa AK, Hamill KJ, Rauz S, Bosworth L, Haneef A, Romano V, Williams RL, Dartt DA, Kaye SB. The conjunctival extracellular matrix, related disorders and development of substrates for conjunctival restoration. Ocul Surf 2023; 28:322-335. [PMID: 34102309 DOI: 10.1016/j.jtos.2021.05.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Revised: 05/05/2021] [Accepted: 05/26/2021] [Indexed: 12/15/2022]
Abstract
The conjunctiva can be damaged by numerous diseases with scarring, loss of tissue and dysfunction. Depending on extent of damage, restoration of function may require a conjunctival graft. A wide variety of biological and synthetic substrates have been tested in the search for optimal conditions for ex vivo culture of conjunctival epithelial cells as a route toward tissue grafts. Each substrate has specific advantages but also disadvantages related to their unique physical and biological characteristics, and identification and development of an improved substrate remains a priority. To achieve the goal of mimicking and restoring a biological material, requires information from the material. Specifically, extracellular matrix (ECM) derived from conjunctival tissue. Knowledge of the composition and structure of native ECM and identifying contributions of individual components to its function would enable using or mimicking those components to develop improved biological substrates. ECM is comprised of two components: basement membrane secreted predominantly by epithelial cells containing laminins and type IV collagens, which directly support epithelial and goblet cell adhesion differentiation and growth and, interstitial matrix secreted by fibroblasts in lamina propria, which provides mechanical and structural support. This review presents current knowledge on anatomy, composition of conjunctival ECM and related conjunctival disorders. Requirements of potential substrates for conjunctival tissue engineering and transplantation are discussed. Biological and synthetic substrates and their components are described in an accompanying review.
Collapse
Affiliation(s)
- Aruni K Makuloluwa
- Department of Eye and Vision Science, University of Liverpool, William Duncan Building, 6 West Derby Street, Liverpool, L7 8TX, UK
| | - Kevin J Hamill
- Department of Eye and Vision Science, University of Liverpool, William Duncan Building, 6 West Derby Street, Liverpool, L7 8TX, UK
| | - Saaeha Rauz
- Academic Unit of Ophthalmology, Institute of Inflammation and Ageing, University of Birmingham and Birmingham and Midland Eye Centre, Dudley Road Birmingham, B18 7QU, UK
| | - Lucy Bosworth
- Department of Eye and Vision Science, University of Liverpool, William Duncan Building, 6 West Derby Street, Liverpool, L7 8TX, UK
| | - Atikah Haneef
- Department of Eye and Vision Science, University of Liverpool, William Duncan Building, 6 West Derby Street, Liverpool, L7 8TX, UK
| | - Vito Romano
- Department of Eye and Vision Science, University of Liverpool, William Duncan Building, 6 West Derby Street, Liverpool, L7 8TX, UK
| | - Rachel L Williams
- Department of Eye and Vision Science, University of Liverpool, William Duncan Building, 6 West Derby Street, Liverpool, L7 8TX, UK
| | - Darlene A Dartt
- Schepens Eye Research Institute, Mass Eye and Ear Infirmary, Harvard Medical School, 20 Staniford St. Boston, MA, 02114, USA
| | - Stephen B Kaye
- Department of Eye and Vision Science, University of Liverpool, William Duncan Building, 6 West Derby Street, Liverpool, L7 8TX, UK.
| |
Collapse
|
5
|
Hatami-Marbini H, Pachenari M. Tensile Viscoelastic Properties of the Sclera after Glycosaminoglycan Depletion. Curr Eye Res 2021; 46:1299-1308. [PMID: 34325593 DOI: 10.1080/02713683.2021.1874026] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
PURPOSE Fibrillar collagen network and glycosaminoglycans (GAGs) are the primary components of extracellular matrix (ECM) of the sclera. The main goal of this study was to investigate the possible structural roles of GAGs in the scleral tensile properties as a function of preconditioning and displacement rate. METHODS Four-step uniaxial stress-relaxation tests were used for characterizing the viscoelastic tensile response of the posterior porcine sclera with and without enzymatic GAG removal. The scleral strips were divided into different groups based on the displacement rate and the presence or absence of a preconditioning step in the loading protocol. The groups were (1) displacement rate of 0.2 mm/min without preconditioning, (2) displacement rate of 1 mm/min without preconditioning, (3) displacement rate of 0.2 mm/min with preconditioning, and (4) displacement rate of 1 mm/min with preconditioning. The peak stress, equilibrium stress, and the equilibrium elastic modulus were calculated for all specimens and compared against each other. RESULTS Increasing the displacement rate from 0.2 mm/min to 1.0 mm/min was found to cause an insignificant change in the equilibrium stress and equilibrium elastic modulus of porcine scleral strips. Removal of GAGs resulted in an overall stiffer tensile behavior independent of the displacement rate in samples that were not preconditioned (P < .05). The behavior of preconditioned samples with and without GAG removal was not significantly different from each other. CONCLUSIONS The experimental measurements of the present study showed that GAGs play an important role in the mechanical properties of the posterior porcine sclera. Furthermore, using a preconditioning step in the uniaxial testing protocol resulted in not being able to identify any significant difference in the tensile behavior of GAG depleted and normal scleral strips.
Collapse
Affiliation(s)
- Hamed Hatami-Marbini
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL, USA
| | - Mohammad Pachenari
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
6
|
Niemczyk M, Danielewska ME, Kostyszak MA, Lewandowski D, Iskander DR. The effect of intraocular pressure elevation and related ocular biometry changes on corneal OCT speckle distribution in porcine eyes. PLoS One 2021; 16:e0249213. [PMID: 33770135 PMCID: PMC7997020 DOI: 10.1371/journal.pone.0249213] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Accepted: 03/14/2021] [Indexed: 11/21/2022] Open
Abstract
The aim of this study was to evaluate the influence of increase in intraocular pressure (IOP) and cooccurring changes in ocular biometry parameters on the corneal optical coherence tomography (OCT) speckle distribution in ex-vivo experiments on porcine intact eyes. Twenty-three eyeballs were used in the inflation test where IOP in the anterior chamber was precisely set from 10 mmHg to 40 mmHg in steps of 5 mmHg and where eye biometry was utilized (IOL Master 700). To assess the influence of the duration of the experiment on the OCT speckle statistics, the second experiment was performed with 10 eyeballs at the constant IOP of 15 mmHg. Based on the OCT scans of central cornea (Copernicus REVO), spatial maps of the scale parameter (a) and the shape parameter (v) of the gamma distribution speckle model were estimated. The means of both parameters for each spatial map were computed within the 2 mm of the central stroma. Both distributional parameters statistically significantly varied with IOP and time (one way repeated measures ANOVA, all p-values < 0.001). The a parameter revealed a faster statistically significant increase in IOP up to 25 mmHg, regardless of time. Central corneal thickness (CCT), the anterior chamber depth, and the mean equivalent spherical power varied significantly with IOP, whereas CCT and axial length changed statistically significantly with time. Statistically significant correlation was found between CCT and the a parameter, after removing IOP as a confounding factor (r = -0.576, p < 0.001). The parameters of the gamma distribution can be used not only for identifying IOP induced changes in the optical scattering within the corneal stroma, but also in corneal geometry. The approach of corneal speckle analysis could be potentially utilized for an indirect and noninvasive assessment of some properties of corneal stroma.
Collapse
Affiliation(s)
- Marcela Niemczyk
- Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland
| | - Monika E. Danielewska
- Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland
| | - Malgorzata A. Kostyszak
- Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland
| | - Daniel Lewandowski
- Department of Mechanics, Materials and Biomedical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland
| | - D. Robert Iskander
- Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland
| |
Collapse
|
7
|
Swain MV, Schroeter N, Nohava J, Eberwein P. Indentation of the cornea: A Bi-layer contact problem. J Mech Behav Biomed Mater 2021; 118:104463. [PMID: 33765544 DOI: 10.1016/j.jmbbm.2021.104463] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Revised: 03/09/2021] [Accepted: 03/11/2021] [Indexed: 11/16/2022]
Abstract
Histological observations of the cornea have identified the presence of multiple layers with differing thickness and function. The composition of the cornea consists primarily of collagen fibrils held together with proteoglycans but with an aqueous interstitial component being dominant. Indentation provides a means to quantify the spatial variation of the mechanical properties of the cornea, however the role of the different layers on the indentation response has barely been addressed. In addition, the response of the fluid content and its displacement during indentation has not been adequately considered. In this study indentation of the cornea with a relatively large spherical tipped indenter (R = 500 μm) is considered. It was observed that the initial phase of loading did not fit a classic Hertz elastic response but showed an initial steeper slope that gradually declines with increasing force and displacement. A relatively simple approach is developed that initially considers the cornea as a poro-elastic bi-layer contact problem, that is the presence of an outer thin stiffer Bowman's layer overlaying the thicker less stiff stroma.
Collapse
Affiliation(s)
- M V Swain
- AMME, Biomechanics Engineering, The University of Sydney, Sydney, NSW, 2004, Australia; Biomechanics Lab, Don State Technical University, Rostov-on-Don, 344010, Russia.
| | - N Schroeter
- Eye Hospital, Medical Faculty Freiburg, University of Freiburg, 79106, Freiburg, Germany
| | - J Nohava
- Anton Paar TriTec SA, Vernets 6, 2035, Corcelles, Switzerland
| | - P Eberwein
- Eye Hospital, Medical Faculty Freiburg, University of Freiburg, 79106, Freiburg, Germany; AugenCentrum Rosenheim, 83322, Rosenheim, Germany
| |
Collapse
|
8
|
Boazak EM, King R, Wang J, Chu CM, Toporek AM, Sherwood JM, Overby DR, Geisert EE, Ethier CR. Smarce1 and Tensin 4 Are Putative Modulators of Corneoscleral Stiffness. Front Bioeng Biotechnol 2021; 9:596154. [PMID: 33634081 PMCID: PMC7902041 DOI: 10.3389/fbioe.2021.596154] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Accepted: 01/14/2021] [Indexed: 11/13/2022] Open
Abstract
The biomechanical properties of the cornea and sclera are important in the onset and progression of multiple ocular pathologies and vary substantially between individuals, yet the source of this variation remains unknown. Here we identify genes putatively regulating corneoscleral biomechanical tissue properties by conducting high-fidelity ocular compliance measurements across the BXD recombinant inbred mouse set and performing quantitative trait analysis. We find seven cis-eQTLs and non-synonymous SNPs associating with ocular compliance, and show by RT-qPCR and immunolabeling that only two of the candidate genes, Smarce1 and Tns4, showed significant expression in corneal and scleral tissues. Both have mechanistic potential to influence the development and/or regulation of tissue material properties. This work motivates further study of Smarce1 and Tns4 for their role(s) in ocular pathology involving the corneoscleral envelope as well as the development of novel mouse models of ocular pathophysiology, such as myopia and glaucoma.
Collapse
Affiliation(s)
- Elizabeth M Boazak
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Emory University, Atlanta, GA, United States
| | - Rebecca King
- Department of Ophthalmology, Emory University, Atlanta, GA, United States
| | - Jiaxing Wang
- Department of Ophthalmology, Emory University, Atlanta, GA, United States
| | - Cassandra M Chu
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Emory University, Atlanta, GA, United States
| | - Aaron M Toporek
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Emory University, Atlanta, GA, United States
| | - Joseph M Sherwood
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Darryl R Overby
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Eldon E Geisert
- Department of Ophthalmology, Emory University, Atlanta, GA, United States
| | - C Ross Ethier
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Emory University, Atlanta, GA, United States.,George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, United States
| |
Collapse
|
9
|
Torres-Netto EA, Spiru B, Kling S, Gilardoni F, Lazaridis A, Sekundo W, Hafezi F. Similar Biomechanical Cross-linking Effect After SMILE and PRK in Human Corneas in an Ex Vivo Model for Postoperative Ectasia. J Refract Surg 2020; 36:49-54. [PMID: 31917851 DOI: 10.3928/1081597x-20191211-01] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Accepted: 12/10/2019] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the biomechanical effect of corneal cross-linking (CXL) in paired human corneas following small incision lenticule extraction (SMILE) or photorefractive keratectomy (PRK) in an ex vivo model for postoperative ectasia. METHODS Twenty-six paired human corneas preserved in tissue culture medium were equally divided into two groups: right and left corneas were treated with PRK and SMILE, respectively. Corneal thickness was measured in all eyes before surgery. Corneas were stretched using an extensometer with two cycles of up to 9 N (570 kPA stress), followed by accelerated CXL with irradiance of 9 mW/cm2 for 10 minutes (fluence 5.4 J/cm2) in both groups. The elastic modulus was evaluated using two-dimensional stress-strain extensometry. RESULTS Following accelerated CXL, the ectatic cornea model showed a mean effective elastic modulus of 17.2 ± 5.3 MPa after PRK and 14.1 ± 5.0 MPa after SMILE. Although the elastic modulus in corneas previously subjected to PRK was higher, there was no significant biomechanical difference between the two groups (P = .093). CONCLUSIONS Under similar conditions, both experimental groups (PRK followed by CXL and SMILE followed by CXL) were characterized by similar biomechanical stability as measured experimentally on ex vivo human fellow corneas. The data suggest that, in the event of postoperative ectasia, the biomechanical improvement achieved by CXL may be similar after PRK and SMILE. [J Refract Surg. 2020;36(1):49-54].
Collapse
|
10
|
Liu T, Shen M, Li H, Zhang Y, Mu B, Zhao X, Wang Y. Changes and quantitative characterization of hyper-viscoelastic biomechanical properties for young corneal stroma after standard corneal cross-linking treatment with different ultraviolet-A energies. Acta Biomater 2020; 113:438-451. [PMID: 32525050 DOI: 10.1016/j.actbio.2020.06.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Revised: 05/30/2020] [Accepted: 06/02/2020] [Indexed: 12/27/2022]
Abstract
Corneal collagen cross-linking (CXL) treatment can restore vision in patients suffering from keratoconus and corneal injury, by improving the mechanical properties of the cornea. The correlation between ultraviolet-A (UVA) irradiant energies of standard CXL (SCXL) and corneal visco-hyperelastic mechanical behavior remains unknown. In this study, SCXL with four different UVA irradiant energy doses (0-5.4 J/cm2) were administered as part of quantitative treatments of corneal stromal lenticules extracted from young myopic patients via small incision lenticule extraction (SMILE) corneal refractive surgery. Double-strip samples with symmetric geometries were cut simultaneously for SCXL treatment and non-treated control. First, 40 pairs of strips were loaded to failure to assess the mechanical parameters of the material. Then, another 40 pairs were tested using a special uniaxial tensile test including quasi-static loading-unloading, instantaneous loading, and stress relaxation, to determine the visco-hyperelastic mechanical behavior. Upon combining the collagen fibril crimping constitutive model with the quasi-linear viscoelastic model, it was observed that with increasing UVA energy dose, the corneal strength and hyperelastic stiffness were significantly enhanced, while the maximum stretch and viscosity of the cornea were significantly reduced. Considering the quantitative analysis of SCXL and the rehabilitation prediction of keratoconus treatment, the results clarify the biomechanical behavior of human corneal stroma in SCXL clinical surgery. STATEMENT OF SIGNIFICANCE: This study quantitatively analyzes the improvement in the biomechanical properties of young central corneal stroma, due to SCXL treatment with different energies. Furthermore, the correlation between the hyper-viscoelastic mechanical parameters and UVA irradiant energy doses of SCXL are clarified. The contribution of this study fills the knowledge gap of the CXL on corneal biomechanics. It can not only clarify this mechanism better but also assist with guiding SCXL surgery for individualized patient corneas.
Collapse
Affiliation(s)
- Taiwei Liu
- Department of Mechanics, School of Mechanical Engineering, Tianjin University, Tianjin 300350 China; Department of Engineering Mechanics, School of Naval Architecture, Ocean and Civil Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Min Shen
- Department of Mechanics, School of Mechanical Engineering, Tianjin University, Tianjin 300350 China.
| | - Hongxun Li
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin 300020 China; Clinical College of Ophthalmology, Tianjin Medical University, Tianjin 300070 China
| | - Yan Zhang
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin 300020 China; Clinical College of Ophthalmology, Tianjin Medical University, Tianjin 300070 China
| | - Bokun Mu
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin 300020 China; Clinical College of Ophthalmology, Tianjin Medical University, Tianjin 300070 China
| | - Xinheng Zhao
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin 300020 China; Clinical College of Ophthalmology, Tianjin Medical University, Tianjin 300070 China
| | - Yan Wang
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin 300020 China; Clinical College of Ophthalmology, Tianjin Medical University, Tianjin 300070 China
| |
Collapse
|
11
|
On influence of sulfated glycosaminoglycans on tensile properties of posterior sclera. ACTA ACUST UNITED AC 2020. [DOI: 10.1007/s42558-020-00025-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
12
|
Li H, Liu T, Mu B, Zhao X, Xue C, Shen M, Jhanji V, Wang Y. Biomechanical effect of ultraviolet-A-riboflavin cross-linking on simulated human corneal stroma model and its correlation with changes in corneal stromal microstructure. Exp Eye Res 2020; 197:108109. [PMID: 32565111 DOI: 10.1016/j.exer.2020.108109] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 05/11/2020] [Accepted: 06/02/2020] [Indexed: 12/28/2022]
Abstract
In this study, we established an experimental human corneal stroma model of simulated cornea tissue composed of thin anterior cornea strips layers obtained from small incision lenticular extraction (SMILE) surgery. We investigated the biomechanical effect of ultraviolet-A- riboflavin cross-linking at different depths of corneal stroma model and correlated it with stromal microstructural changes examined by transmission electron microscopy (TEM). Corneal strips were harvested from fresh human corneal lenticules obtained after SMILE surgery. Experimental models (n = 34) were established by superimposing the corneal lenticule strips until their thickness reached close to 500 μm. Corneal cross-linking (CXL) was performed subsequently using standard or accelerated protocol. Elasticity and viscosity were quantified using stress-strain extensometer. TEM was used to visualize the collagen fiber diameter and interfibrillar spacing. The relative change in Young's modulus (rel. ΔE) decreased nonlinearly with increasing stromal depth both in the standard and accelerated groups. Compared to the sham controls, the rel. ΔE in standard and accelerated CXL groups increased significantly in the anterior 400 μm and 275 μm depth, respectively. Also, the relative change in stress (rel. ΔS) was significantly lower after standard and accelerated CXL compared to sham controls. Depth analysis showed similar results for the elastic effect. TEM images showed a small, non-significant increase in fibril diameter. The interfibrillar spacing decreased significantly after standard and accelerated CXL in the anterior-mid stromal region. We noted that the increase of corneal stiffness correlated with decrease in interfibrillar spacing after CXL. The stiffening effect was depth dependent. The effect of accelerated CXL was less in the deep corneal stromal regions compared to standard CXL.
Collapse
Affiliation(s)
- Hongxun Li
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China; Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital Tianjin, China
| | - Taiwei Liu
- Department of Mechanics, School of Mechanical Engineering, Tianjin University, Tianjin, China
| | - Bokun Mu
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China; Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital Tianjin, China
| | - Xinheng Zhao
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China; Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital Tianjin, China
| | - Chao Xue
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
| | - Min Shen
- Department of Mechanics, School of Mechanical Engineering, Tianjin University, Tianjin, China
| | - Vishal Jhanji
- Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
| | - Yan Wang
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China; Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital Tianjin, China.
| |
Collapse
|
13
|
Hydration related changes in tensile response of posterior porcine sclera. J Mech Behav Biomed Mater 2020; 104:103562. [DOI: 10.1016/j.jmbbm.2019.103562] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 11/05/2019] [Accepted: 11/26/2019] [Indexed: 11/18/2022]
|
14
|
Hatami-Marbini H, Pachenari M. The contribution of sGAGs to stress-controlled tensile response of posterior porcine sclera. PLoS One 2020; 15:e0227856. [PMID: 32084141 PMCID: PMC7034872 DOI: 10.1371/journal.pone.0227856] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Accepted: 12/31/2019] [Indexed: 11/19/2022] Open
Abstract
Despite the significant progress in characterizing mechanical functions of individual scleral extracellular matrix (ECM) components, the biomechanical contribution of sulfated glycosaminoglycans (sGAGs) is still poorly understood. The primary purpose of this study was to determine the possible function of sGAGs in scleral mechanical response by characterizing the tensile behavior of normal and sGAG-depleted samples. We used chondroitinase ABC solution to remove sGAGs from scleral samples that were dissected from posterior porcine eyes. We performed biochemical analyses for assessing the efficacy of sGAG removal protocol. Furthermore, we conducted stress-controlled uniaxial tensile tests to characterize the influence of sGAG removal on mechanical properties of sclera. The tensile behavior of scleral strips right after dissection and after being soaked in buffer was also determined. Biochemical analyses confirmed that 18 hour incubation in 0.125 U/ml Chondroitinase ABC solution removed over 90% of chondroitin and dermatan sGAGs. No significant difference was observed in the thickness/hydration of samples because of enzyme- and buffer-treated samples. Furthermore, it was found that sGAG depletion did not significantly alter the tangent modulus, energy dissipation, and peak strain of posterior scleral strips. It was concluded that sGAGs did not influence the stress-controlled viscoelastic tensile response of sclera.
Collapse
Affiliation(s)
- Hamed Hatami-Marbini
- Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, Illinois, United States of America
| | - Mohammad Pachenari
- Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, Illinois, United States of America
| |
Collapse
|
15
|
Corneal pulsation and biomechanics during induced ocular pulse. An ex-vivo pilot study. PLoS One 2020; 15:e0228920. [PMID: 32053692 PMCID: PMC7018024 DOI: 10.1371/journal.pone.0228920] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Accepted: 01/15/2020] [Indexed: 01/16/2023] Open
Abstract
The purpose of this study was to ascertain the relationships between the amplitude of the corneal pulse (CP) signal and the parameters of corneal biomechanics during ex-vivo intraocular pressure (IOP) elevation experiments on porcine eyes with artificially induced ocular pulse cycles. Two experiments were carried out using porcine eyes. In the first one, a selected eye globe was subjected to three IOP levels (15, 30 and 45 mmHg), where changes in physical ocular pulse amplitude were controlled by infusion/withdrawal volumes (ΔV). In the second experiment, six eyes were subjected to IOP from 15 mmHg to 45 mmHg in steps of 5 mmHg with a constant ΔV, where corneal deformation parameters were measured using Corvis ST. In both experiments, at each IOP, the CP and IOP signals were acquired synchronically using a non-contact ultrasonic distance sensor and a pressure transmitter, respectively. Based on the amplitudes of the CP and IOP signals ocular pulse based corneal rigidity index (OPCRI) was calculated. Results indicate positive correlations between ΔV and the physical ocular pulse amplitude, and between ΔV and the corneal pulse amplitude (both p < 0.001). OPCRI was found to increase with elevated IOP. Furthermore, IOP statistically significantly differentiated changes in OPCRI, the amplitudes of CP and IOP signals and in most of the corneal deformation parameters (p < 0.05). The partial correlation analysis, with IOP as a control variable, revealed a significant correlation between the length of the flattened cornea during the first applanation (A1L) and the corneal pulse amplitude (p = 0.002), and between A1L and OPCRI (p = 0.003). In conclusion, this study proved that natural corneal pulsations, detected with a non-contact ultrasonic technique, reflect pressure-volume dynamics and can potentially be utilized to assess stiffness of the cornea. The proposed new rigidity index could be a simple approach to estimating corneal rigidity.
Collapse
|
16
|
Clayson K, Sandwisch T, Ma Y, Pavlatos E, Pan X, Liu J. Corneal Hydration Control during Ex Vivo Experimentation Using Poloxamers. Curr Eye Res 2019; 45:111-117. [PMID: 31474157 DOI: 10.1080/02713683.2019.1663387] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Purpose: The purpose of this study was to develop an effective treatment method using poloxamers to restore and maintain physiological hydration in postmortem porcine and human corneas during ex vivo experimentation, and to compare corneal inflation response with or without treatment.Materials and Methods: Corneal buttons obtained from whole globes (n = 30 porcine, n = 8 human) were treated with various concentrations of poloxamer 188 (P188, a synthetic macromolecule surfactant) for 24 hrs to identify the concentration that would return the cornea to near-physiological hydration (i.e. H = 3.2). Whole globes (n = 12 porcine, n = 16 human) were also used to monitor central corneal thickness (CCT) during deswelling treatment. Inflation testing from 5 to 30 mmHg was performed in the porcine globes and a subset of human globes to characterize the mechanical response of the cornea after treatment.Results: Physiological hydration was obtained after 24 hrs immersion in 3.25% P188 for porcine corneas and 4.25% P188 treatment for human corneas. CCT was stabilized and returned to physiological levels after 24 hrs of treatment in 3.25% P188 in porcine (891 ± 66 µm) and 4.25% P188 in human (574 ± 34 µm) whole globes. Corneal axial strains at 30 mmHg were significantly larger at physiological hydration than in swollen cornea in both porcine (-6.42%±1.50% vs. -3.64%±1.05%, p = .004) and human (-2.85%±0.09% in vs. -1.53%±0.27%, p = .031) eyes.Conclusions: Our results suggest that P188 treatment was effective in restoring and maintaining near physiological corneal hydration during ex vivo testing, and hydration appeared to significantly impact corneal inflation response in both porcine and human eyes.
Collapse
Affiliation(s)
- Keyton Clayson
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio, USA.,Biophysics Graduate Program, The Ohio State University, Columbus, Ohio, USA
| | - Thomas Sandwisch
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio, USA
| | - Yanhui Ma
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio, USA
| | - Elias Pavlatos
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio, USA
| | - Xueliang Pan
- Department of Biomedical Informatics, The Ohio State University, Columbus, Ohio, USA
| | - Jun Liu
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio, USA.,Biophysics Graduate Program, The Ohio State University, Columbus, Ohio, USA.,Department of Ophthalmology and Visual Science, The Ohio State University, Columbus, Ohio, USA
| |
Collapse
|
17
|
Masterton S, Ahearne M. Mechanobiology of the corneal epithelium. Exp Eye Res 2018; 177:122-129. [PMID: 30086260 PMCID: PMC6280025 DOI: 10.1016/j.exer.2018.08.001] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Revised: 07/16/2018] [Accepted: 08/03/2018] [Indexed: 12/16/2022]
Abstract
There has been a drive to develop new cell based therapies to treat corneal blindness, one of the most common causes of blindness worldwide. Mechanical and physical cues are known to regulate the behavior of many cell types, however studies examining these effects on corneal epithelial cells have been limited in number and their findings have not previously been amalgamated and contrasted. Here, we provide an overview of the different types of mechanical stimuli to which the corneal epithelium is exposed and the influence that these have on the cells. Shear stress from the tear film motion and blinking, extracellular matrix stiffness and external physical forces such as eye rubbing and contact lens wear are among some of the forms of mechanical stimuli that the epithelium experiences. In vivo and in vitro studies examining the mechanobiology on corneal epithelial cells under differing mechanical environments are explored. A greater understanding of the mechanobiology of the corneal epithelium has the potential to lead to improved tissue engineering and cell based therapies to repair and regenerate damaged cornea.
Collapse
Affiliation(s)
- Sophia Masterton
- Dept of Mechanical and Manufacturing Engineering, School of Engineering, Trinity College Dublin, University of Dublin, Ireland; Trinity Centre for Bioengineering, Trinity Biomedical Science Institute, Trinity College Dublin, University of Dublin, Ireland
| | - Mark Ahearne
- Dept of Mechanical and Manufacturing Engineering, School of Engineering, Trinity College Dublin, University of Dublin, Ireland; Trinity Centre for Bioengineering, Trinity Biomedical Science Institute, Trinity College Dublin, University of Dublin, Ireland.
| |
Collapse
|
18
|
Hatami-Marbini H. Influence of Microstructure on Stiffening Effects of Corneal Cross-linking Treatment. J Refract Surg 2018; 34:622-627. [DOI: 10.3928/1081597x-20180718-01] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Accepted: 07/09/2018] [Indexed: 11/20/2022]
|
19
|
Relationship between initial corneal hydration and stiffening effects of corneal crosslinking treatment. J Cataract Refract Surg 2018; 44:756-764. [PMID: 30041742 DOI: 10.1016/j.jcrs.2018.01.036] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Revised: 11/18/2017] [Accepted: 01/17/2018] [Indexed: 11/21/2022]
Abstract
PURPOSE To characterize the mechanical property improvement of riboflavin and ultraviolet light corneal crosslinking (CXL) procedure in artificially swollen human and porcine corneas. SETTING Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Illinois, USA. DESIGN Experimental study. METHODS Porcine and human donor corneas were crosslinked at different hydration levels using riboflavin-dextran solutions of different osmolality. Four porcine groups (Hw [hydration in mg H2O/mg dry tissue] = 3.3 ± 0.2 [SD]; 4.0 ± 0.1; 5.1 ± 0.1; 5.6 ± 0.1) and 3 human groups (Hw = 3.2 ± 0.1; 3.9 ± 0.2; 5.3 ± 0.3) were considered. The mechanical properties were measured by uniaxial tensile experiments during which the hydration of samples was the same as the hydration at which they were crosslinked. Tensile properties of 2 porcine groups (Hw = 5.1 ± 0.1; 5.6 ± 0.1) were also measured when their average hydration was lowered to 4.0 mg H2O/mg dry tissue. RESULTS The CXL procedure significantly increased tensile properties of both human and porcine samples in each hydration group (P < .05). The improvement in tensile properties was hydration-dependent, that is, samples crosslinked at higher hydration levels showed lower maximum tensile stress. The behavior of samples crosslinked at different initial hydration but tested mechanically at similar hydration showed insignificant difference (P = .7). CONCLUSION Increasing the hydration of porcine and human corneal samples before the CXL treatment had insignificant influence on tensile property improvement, as measured by testing specimens at similar hydration.
Collapse
|
20
|
Hatami-Marbini H, Jayaram SM. UVA/riboflavin collagen crosslinking stiffening effects on anterior and posterior corneal flaps. Exp Eye Res 2018; 176:53-58. [PMID: 29777678 DOI: 10.1016/j.exer.2018.05.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 05/04/2018] [Accepted: 05/15/2018] [Indexed: 10/16/2022]
Abstract
The UVA/riboflavin collagen crosslinking (CXL) is one of the treatment procedure for stopping the progression of keratoconus. The inclusion criterion for this procedure is a minimum corneal thickness of 400 μm, which is not often met in patients with advanced keratoconus. Preoperatively swelling thin corneas was shown to stabilize the keratectasia without any postoperative endothelial damage. Recently, we have shown that swelling porcine corneas prior to the CXL treatment had no significant effect on the resulting improvement in their tensile properties. In the present study, we extended this previous study and characterized the stiffening effects of CXL on anterior and posterior flaps as a function of their hydration. A DSAEK system was used to excise 10 mm corneal flaps from 80 porcine corneas. Individual flaps were crosslinked at different initial hydration levels by using riboflavin solutions composed of different dextran concentrations; the thickness was taken as a measure of flap hydration. A DMA machine was used to measure the tensile properties either immediately after the CXL treatment or after the thickness (hydration) of the crosslinked samples was brought down to a specific value. The average thickness of anterior groups was 670 μm, 540 μm, and 410 μm, and the average thickness of posterior groups was 845 μm, 650 μm, and 440 μm. It was found that although CXL significantly increased the tensile properties of all anterior groups, it had an insignificant effect on the stiffness of posterior flaps. Furthermore, except for the posterior flaps in 845 μm and 650 μm thickness groups, decreasing the hydration significantly increased the tensile modulus (p < 0.05). Finally, the anterior flaps that were crosslinked at higher hydration, i.e. swollen before CXL, showed significantly less amount of stiffening in comparison with those crosslinked at lower hydration when the tensile property measurement was done at similar hydration (p < 0.05).
Collapse
Affiliation(s)
- Hamed Hatami-Marbini
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL, USA.
| | - Sandeep M Jayaram
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
21
|
Rogala MM, Danielewska ME, Antończyk A, Kiełbowicz Z, Rogowska ME, Kozuń M, Detyna J, Iskander DR. In-vivo corneal pulsation in relation to in-vivo intraocular pressure and corneal biomechanics assessed in-vitro. An animal pilot study. Exp Eye Res 2017; 162:27-36. [PMID: 28689748 DOI: 10.1016/j.exer.2017.07.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2016] [Revised: 06/30/2017] [Accepted: 07/05/2017] [Indexed: 01/27/2023]
Abstract
The aim was to ascertain whether the characteristics of the corneal pulse (CP) measured in-vivo in a rabbit eye change after short-term artificial increase of intraocular pressure (IOP) and whether they correlate with corneal biomechanics assessed in-vitro. Eight New Zealand white rabbits were included in this study and were anesthetized. In-vivo experiments included simultaneous measurements of the CP signal, registered with a non-contact method, IOP, intra-arterial blood pressure, and blood pulse (BPL), at the baseline and short-term elevated IOP. Afterwards, thickness of post-mortem corneas was determined and then uniaxial tensile tests were conducted leading to estimates of their Young's modulus (E). At the baseline IOP, backward stepwise regression analyses were performed in which successively the ocular biomechanical, biometric and cardiovascular predictors were separately taken into account. Results of the analysis revealed that the 3rd CP harmonic can be statistically significantly predicted by E and central corneal thickness (Models: R2 = 0.662, p < 0.005 and R2 = 0.832, p < 0.001 for the signal amplitude and power, respectively). The 1st CP harmonic can be statistically significantly predicted by the amplitude and power of the 1st BPL harmonic (Models: R2 = 0.534, p = 0.015 and R2 = 0.509, p < 0.018, respectively). For elevated IOP, non-parametric analysis indicated significant differences for the power of the 1st CP harmonic (Kruskal-Wallis test; p = 0.031) and for the mean, systolic and diastolic blood pressures (p = 0.025, p = 0.019, p = 0.033, respectively). In conclusion, for the first time, the association between parameters of the CP signal in-vivo and corneal biomechanics in-vitro was confirmed. In particular, spectral analysis revealed that higher amplitude and power of the 3rd CP harmonic indicates higher corneal stiffness, while the 1st CP harmonic correlates positively with the corresponding harmonic of the BPL signal.
Collapse
Affiliation(s)
- Maja M Rogala
- Wroclaw University of Science and Technology, Department of Mechanics, Materials Science and Engineering, Faculty of Mechanical Engineering, ul. Smoluchowskiego 25, 50-370 Wroclaw, Poland.
| | - Monika E Danielewska
- Wroclaw University of Science and Technology, Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland.
| | - Agnieszka Antończyk
- Wroclaw University of Environmental and Life Sciences, Department of Surgery, Faculty of Veterinary Medicine, pl. Grunwaldzki 51, 50-366 Wroclaw, Poland.
| | - Zdzisław Kiełbowicz
- Wroclaw University of Environmental and Life Sciences, Department of Surgery, Faculty of Veterinary Medicine, pl. Grunwaldzki 51, 50-366 Wroclaw, Poland.
| | - Marta E Rogowska
- Wroclaw University of Science and Technology, Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland.
| | - Marta Kozuń
- Wroclaw University of Science and Technology, Department of Biomedical Engineering, Mechatronics and Theory of Mechanisms, Faculty of Mechanical Engineering, ul. Lukasiewicza 7/9, 50-371 Wroclaw, Poland.
| | - Jerzy Detyna
- Wroclaw University of Science and Technology, Department of Mechanics, Materials Science and Engineering, Faculty of Mechanical Engineering, ul. Smoluchowskiego 25, 50-370 Wroclaw, Poland.
| | - D Robert Iskander
- Wroclaw University of Science and Technology, Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland.
| |
Collapse
|
22
|
Medina A. Plastic modification of the cornea by pneumatic force corrects myopia: Pneumatic keratology. Eye (Lond) 2017. [PMID: 28622329 DOI: 10.1038/eye.2017.123] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PurposeThe eyeball and, in particular, the cornea deform in vitro by the application of a distending force like other visco-elastic tissue. If the force is large enough, the cornea strains beyond the elastic range, and a permanent deformation occurs. Such permanent strain is referred to as 'plastic' strain. The phenomenon, however, has never been observed or produced on living tissue. This report seeks to demonstrate that the central radius of a patient's cornea can be altered in a controlled manner designed to correct refractive errors.MethodsTo plastically deform the living cornea, we applied a vacuum to the cornea of eight rabbits and five human eyes with a novel device. This device consists of a chamber of 11 mm in diameter. The chamber is radially divided into four interconnected sub-chambers.ResultsHere we show that a strain can be achieved in vivo with a force produced by the application of the specially designed chamber where air is evacuated. An anatomical modification of the cornea of humans and rabbits was achieved. The deformation of the cornea was plastic, and therefore permanent.ConclusionsThe method described here-Pneumatic Keratology- can be used to alter the cornea by non-invasive means. A vacuum chamber with radial openings alters the collagen fibers in the stroma and flattens the cornea. A flatter cornea corrects or reduces myopia.
Collapse
Affiliation(s)
- A Medina
- Massachusetts Institute Of Technology EE Research Laboratory, Cambridge, MA, USA
| |
Collapse
|
23
|
Abstract
OBJECTIVES To determine the effect of hydration media on ex vivo corneal elasticity. METHODS Experiments were conducted on 40 porcine eyes retrieved from an abattoir (10 eyes each for phosphate-buffered saline (PBS), balanced salt solution, Optisol, 15% dextran). The epithelium was removed, and the cornea was excised with an intact scleral rim and placed in 20% dextran overnight to restore its physiological thickness. For each hydration media, corneas were evenly divided into two groups: one with an intact scleral rim and the other without. Corneas were mounted onto a custom chamber and immersed in a hydration medium for elasticity testing. Although in each medium, corneal elasticity measurements were performed for 2 hr: at 5-min intervals for the first 30 min and then 15-min intervals for the remaining 90 min. Elasticity testing was performed using nanoindentation with spherical indenters, and Young modulus was calculated using the Hertz model. Thickness measurements were taken before and after elasticity testing. RESULTS The percentage change in corneal thickness and elasticity was calculated for each hydration media group. Balanced salt solution, PBS, and Optisol showed an increase in thickness and Young moduli for corneas with and without an intact scleral rim. Fifteen percent dextran exhibited a dehydrating effect on corneal thickness and provided stable maintenance of corneal elasticity for both groups. CONCLUSIONS Hydration media affects the stability of corneal thickness and elasticity measurements over time. Fifteen percent dextran was most effective in maintaining corneal hydration and elasticity, followed by Optisol.
Collapse
|
24
|
Hatami-Marbini H, Maulik R. A Biphasic Transversely Isotropic Poroviscoelastic Model for the Unconfined Compression of Hydrated Soft Tissue. J Biomech Eng 2016; 138:4032059. [DOI: 10.1115/1.4032059] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Indexed: 11/08/2022]
Abstract
The unconfined compression experiments are commonly used for characterizing the mechanical behavior of hydrated soft tissues such as articular cartilage. Several analytical constitutive models have been proposed over the years to analyze the unconfined compression experimental data and subsequently estimate the material parameters. Nevertheless, new mathematical models are still required to obtain more accurate numerical estimates. The present study aims at developing a linear transversely isotropic poroviscoelastic theory by combining a viscoelastic material law with the transversely isotropic biphasic model. In particular, an integral type viscoelastic model is used to describe the intrinsic viscoelastic properties of a transversely isotropic solid matrix. The proposed constitutive theory incorporates viscoelastic contributions from both the fluid flow and the intrinsic viscoelasticity to the overall stress-relaxation behavior. Moreover, this new material model allows investigating the biomechanical properties of tissues whose extracellular matrix exhibits transverse isotropy. In the present work, a comprehensive parametric study was conducted to determine the influence of various material parameters on the stress–relaxation history. Furthermore, the efficacy of the proposed theory in representing the unconfined compression experiments was assessed by comparing its theoretical predictions with those obtained from other versions of the biphasic theory such as the isotropic, transversely isotropic, and viscoelastic models. The unconfined compression behavior of articular cartilage as well as corneal stroma was used for this purpose. It is concluded that while the proposed model is capable of accurately representing the viscoelastic behavior of any hydrated soft tissue in unconfined compression, it is particularly useful in modeling the behavior of those with a transversely isotropic skeleton.
Collapse
Affiliation(s)
- H. Hatami-Marbini
- Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL 60607 e-mail:
| | - R. Maulik
- School of Mechanical and Aerospace Engineering, Oklahoma State University, Stillwater, OK 74075
| |
Collapse
|
25
|
Hatami-Marbini H, Rahimi A. Interrelation of Hydration, Collagen Cross-Linking Treatment, and Biomechanical Properties of the Cornea. Curr Eye Res 2015; 41:616-22. [PMID: 26126201 DOI: 10.3109/02713683.2015.1042546] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE The present study was designed to investigate the effects of hydration and collagen cross-linking treatment on biomechanical properties of the cornea. METHODS The original corneal collagen cross-linking protocol was used to induce cross-links in bovine corneas. The thickness of samples was used as a measure of their hydration and five different thickness groups (n = 5 each) were considered. The cross-linked corneal strips were allowed to hydrate/dehydrate until their thickness reached 500, 700, 900, 1100, and 1500 μm. The tensile behavior of specimens in each thickness group was characterized by conducting uniaxial tensile experiments. The experiments were done in mineral oil in order to keep the thickness of samples constant and minimize hydration changes. RESULTS It was observed that collagen cross-linking treatment significantly increased both the maximum tensile stress and the equilibrium (relaxed) stress of the bovine cornea (p < 0.01). Furthermore, with increasing the thickness (hydration) of the collagen cross-linked samples, their tensile stiffness significantly decreased (p < 0.01). An exponential relation and a logarithmic expression successfully represented experimentally measured stress-strain behavior and relaxation response of all groups (r(2 )> 0.99), respectively. CONCLUSION Hydration and collagen cross-linking treatment concomitantly affect biomechanical properties of the cornea. Therefore, an accurate estimate of stiffening effects of collagen cross-linking treatment option using uniaxial tensile experiments is only possible if the hydration of specimens is fully controlled.
Collapse
Affiliation(s)
- Hamed Hatami-Marbini
- a Computational Biomechanics Laboratory, School of Mechanical and Aerospace Engineering, Oklahoma State University , Stillwater , OK , USA
| | - Abdolrasol Rahimi
- a Computational Biomechanics Laboratory, School of Mechanical and Aerospace Engineering, Oklahoma State University , Stillwater , OK , USA
| |
Collapse
|
26
|
Corneal Collagen Cross-linking Combined With Simulation of Femtosecond Laser–Assisted Refractive Lens Extraction. Cornea 2015; 34:550-6. [DOI: 10.1097/ico.0000000000000376] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
27
|
Hatami-Marbini H, Rahimi A. Collagen cross-linking treatment effects on corneal dynamic biomechanical properties. Exp Eye Res 2015; 135:88-92. [PMID: 25887295 DOI: 10.1016/j.exer.2015.04.005] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2014] [Revised: 02/10/2015] [Accepted: 04/13/2015] [Indexed: 10/23/2022]
Abstract
Cornea is a soft tissue with the principal function of transmitting and refracting light rays. The objective of the current study was to characterize possible effects of the riboflavin/UVA collagen cross-linking on corneal dynamic properties. The original corneal cross-linking protocol was used to induce cross-links in the anterior portion of the bovine cornea. A DMA machine was used to conduct mechanical tensile experiments at different levels of tensile strains. The samples were divided into a control group (n = 5) and a treated group (n = 5). All specimens were first stretched to a strain of 5% and allowed to relax for twenty minutes. After completion of the stress-relaxation experiment, a frequency sweep test with oscillations ranging from 0.01 to 10 Hz was performed. The same procedure was repeated to obtain the stress-relaxation and dynamic properties at 10% strain. It was observed that the collagen cross-linking therapy significantly increased the immediate and equilibrium tensile behavior of the bovine cornea (P < 0.05). Furthermore, for all samples in control and treated groups and throughout the whole range of frequencies, a significantly larger tensile storage modulus was measured at an axial strain of 10% compared to what was obtained at a tensile strain of 5%. Finally, it was noted that although this treatment procedure resulted in a significant increase in the storage and loss modulus at any axial strain and frequency (P < 0.05), it significantly reduced the ratio of the dissipated and stored energy during a single cycle of deformation. Therefore, it was concluded that while the riboflavin/UVA collagen cross-linking increased significantly corneal stiffness, it decreased significantly its damping capability and deformability. This reduced damping ability might adversely interfere with corneal mechanical performance.
Collapse
Affiliation(s)
- Hamed Hatami-Marbini
- Computational Biomechanics Laboratory, School of Mechanical and Aerospace Engineering, Oklahoma State University, Stillwater, OK, USA.
| | - Abdolrasol Rahimi
- Computational Biomechanics Laboratory, School of Mechanical and Aerospace Engineering, Oklahoma State University, Stillwater, OK, USA
| |
Collapse
|
28
|
Kanellopoulos AJ, Asimellis G, Salvador-Culla B, Chodosh J, Ciolino JB. High-irradiance CXL combined with myopic LASIK: flap and residual stroma biomechanical properties studied ex-vivo. Br J Ophthalmol 2015; 99:870-4. [DOI: 10.1136/bjophthalmol-2014-306411] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2014] [Accepted: 02/15/2015] [Indexed: 11/03/2022]
|
29
|
Grytz R, Siegwart JT. Changing material properties of the tree shrew sclera during minus lens compensation and recovery. Invest Ophthalmol Vis Sci 2015; 56:2065-78. [PMID: 25736788 DOI: 10.1167/iovs.14-15352] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
PURPOSE To estimate two collagen-specific material properties (crimp angle and elastic modulus of collagen fibrils) of the remodeling tree shrew sclera during monocular -5 diopter (D) lens wear and recovery. METHODS Tensile tests were performed on scleral strips obtained from juvenile tree shrews exposed to three different visual conditions: normal, monocular -5 D lens wear to induce myopia, and recovery. Collagen fibrils are crimped in the unloaded sclera and uncrimp as the tissue stiffens under load. Inverse numerical analyses were performed to estimate the (unloaded) crimp angle and elastic modulus of collagen fibrils using a microstructure-based constitutive model. RESULTS Compared with the control eye, the crimp angle was significantly higher in the treated eye after 2 days and remained significantly higher until 21 days of lens wear (P < 0.05). The difference between the crimp angle of the treated and control eye rapidly vanished during recovery in concert with the changes in axial elongation rate. A rapid and extensive increase in the elastic modulus was seen in both eyes after starting and stopping the lens wear. CONCLUSIONS The estimated change in the crimp of scleral collagen fibrils is temporally associated with the change in axial elongation rate during myopia development and recovery. This finding suggests that axial elongation may be controlled by a remodeling mechanism that modulates the collagen fibril crimp. The observed binocular changes in scleral stiffness are not temporally associated with the axial elongation rate, indicating that scleral stiffening may not be causally related to myopia.
Collapse
Affiliation(s)
- Rafael Grytz
- Department of Ophthalmology, University of Alabama at Birmingham, Birmingham, Alabama, United States
| | - John T Siegwart
- Department of Vision Sciences, University of Alabama at Birmingham, Birmingham, Alabama, United States
| |
Collapse
|
30
|
Hatami-Marbini H, Rahimi A. Evaluation of hydration effects on tensile properties of bovine corneas. J Cataract Refract Surg 2015; 41:644-51. [DOI: 10.1016/j.jcrs.2014.07.029] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2014] [Revised: 06/12/2014] [Accepted: 07/11/2014] [Indexed: 11/27/2022]
|
31
|
Hatami-Marbini H, Rahimi A. Stiffening effects of riboflavin/UVA corneal collagen cross-linking is hydration dependent. J Biomech 2015; 48:1052-7. [PMID: 25704532 DOI: 10.1016/j.jbiomech.2015.01.038] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2014] [Revised: 10/03/2014] [Accepted: 01/25/2015] [Indexed: 10/24/2022]
Abstract
The collagen cross-linking is a relatively new treatment option for strengthening the cornea, delaying, and in some cases stopping the progression of keratoconus. The uniaxial tensile experiments are among the most commonly used techniques to assess the effectiveness of this therapeutic option in enhancing tensile properties. In the present study, we investigated the possible effects of hydration on stiffening effects of corneal collagen cross-linking procedure, as measured by the uniaxial tensile testing method. For this purpose, after cross-linking bovine corneas, we let the strips to dehydrate in air or swell in a solution until their thickness reached an average thickness of 0.5, 0.7, 0.9, 1.1, and 1.5 mm. Using thickness as a representative of hydration, we divided corneal strips into five different groups and measured their stress-strain behavior by conducting uniaxial tensile experiments in mineral oil. It was observed that the collagen cross-linking treatment and hydration together affect the tensile behavior of the bovine cornea. While corneal collagen cross-linking resulted in a significant increase in the tensile stress-strain response of each thickness group (P<0.01), less hydrated collagen cross-linked samples showed a significantly stiffer response (P<0.01). A master curve was found for representing the tensile behavior of the collagen cross-linked bovine cornea at different levels of hydration. The results of the present research confirmed that the amount of mechanical stiffening of the corneal collagen cross-linking, as measured by uniaxial tensile testing, strongly depends on the hydration. Therefore, it is concluded that uniaxial tensile experiments could only be used to assess stiffening effects of the collagen cross-linking treatment if the hydration of specimens is fully controlled.
Collapse
Affiliation(s)
- H Hatami-Marbini
- School of Mechanical and Aerospace Engineering, Oklahoma State University, Stillwater, OK 74078, United States.
| | - A Rahimi
- School of Mechanical and Aerospace Engineering, Oklahoma State University, Stillwater, OK 74078, United States
| |
Collapse
|
32
|
Lombardo G, Serrao S, Rosati M, Lombardo M. Analysis of the viscoelastic properties of the human cornea using Scheimpflug imaging in inflation experiment of eye globes. PLoS One 2014; 9:e112169. [PMID: 25397674 PMCID: PMC4232387 DOI: 10.1371/journal.pone.0112169] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2014] [Accepted: 10/13/2014] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To demonstrate a Scheimpflug-based imaging procedure for investigating the depth- and time-dependent strain response of the human cornea to inflation testing of whole eye globes. METHODS Six specimens, three of which with intact corneal epithelium, were mounted in a customized apparatus within a humidity and temperature-monitored wet chamber. Each specimen was subjected to two mechanical tests in order to measure corneal strain resulting from application of cyclic (cyclic regimen) and constant (creep regimen) stress by changing the intra-ocular pressure (IOP) within physiological ranges (18-42 mmHg). Corneal shape changes were analyzed as a function of IOP and both corneal stress-strain curves and creep curves were generated. RESULTS The procedure was highly accurate and repeatable. Upon cyclic stress application, a biomechanical corneal elasticity gradient was found in the front-back direction. The average Young's modulus of the anterior cornea ranged between 2.28±0.87 MPa and 3.30±0.90 MPa in specimens with and without intact epithelium (P = 0.05) respectively. The Young's modulus of the posterior cornea was on average 0.21±0.09 MPa and 0.17±0.06 MPa (P>0.05) respectively. The time-dependent strain response of the cornea to creep testing was quantified by fitting data to a modified Zener model for extracting both the relaxation time and compliance function. CONCLUSION Cyclic and creep mechanical tests are valuable for investigating the strain response of the intact human cornea within physiological IOP ranges, providing meaningful results that can be translated to clinic. The presence of epithelium influences the results of anterior corneal shape changes when monitoring deformation via Scheimpflug imaging in inflation experiments of whole eye globes.
Collapse
Affiliation(s)
- Giuseppe Lombardo
- CNR-IPCF, Unit of Support of Cosenza, Ponte P. Bucci, 87036 Rende, Italy
- Vision Engineering Italy S.r.l., Via Adda 7, 00198 Rome, Italy
- * E-mail: (ML); (GL)
| | | | - Marianna Rosati
- Fondazione G.B. Bietti IRCCS, Via Livenza 3, 00198 Rome, Italy
| | - Marco Lombardo
- Fondazione G.B. Bietti IRCCS, Via Livenza 3, 00198 Rome, Italy
- * E-mail: (ML); (GL)
| |
Collapse
|
33
|
Hatami-Marbini H, Rahimi A. The relation between hydration and mechanical behavior of bovine cornea in tension. J Mech Behav Biomed Mater 2014; 36:90-7. [DOI: 10.1016/j.jmbbm.2014.03.011] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2014] [Revised: 03/15/2014] [Accepted: 03/18/2014] [Indexed: 11/30/2022]
|
34
|
Hydration dependent viscoelastic tensile behavior of cornea. Ann Biomed Eng 2014; 42:1740-8. [PMID: 24668183 DOI: 10.1007/s10439-014-0996-6] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2013] [Accepted: 03/07/2014] [Indexed: 10/25/2022]
Abstract
The cornea is a protective transparent connective tissue covering the front of the eye. The standard uniaxial tensile experiments are among the most popular techniques for investigating biomechanical properties of the cornea. This experimental method characterizes the stress-strain response of corneal strips immersed in a bathing solution. In the present study, the important roles of corneal hydration on tensile viscoelastic properties were investigated. The thickness was used as a surrogate for hydration and uniaxial tensile experiments were performed on bovine corneal samples with four different average thickness (hydration), i.e., 1100 μm (4.87 mg water/mg dry tissue), 900 μm (4.13 mg water/mg dry tissue), 700 μm (3.20 mg water/mg dry tissue), and 500 μm (1.95 mg water/mg dry tissue). The samples were immersed in mineral oil in order to prevent their swelling during the experiments. A quasilinear viscoelastic (QLV) model was used to analyze the experimental measurements and determine viscoelastic material constants. It was observed that both maximum and equilibrium (relaxed) stresses were exponentially increased with decreasing tissue thickness (hydration). Furthermore, the QLV model successfully captured the corneal viscoelastic response with an average R (2) value greater than 0.99. Additional experiments were conducted in OBSS in order to confirm that these significant changes in viscoelastic properties were because of corneal hydration and not the bathing solution. The findings of this study suggest that extra care must be taken in interpreting the results of earlier uniaxial tensile testings and their correspondence to the corneal biomechanical properties.
Collapse
|