1
|
Park DG, Kwon JG, Ha ES, Kang B, Choi I, Kwak JE, Choi J, Lee W, Kim SH, Kim SH, Park J, Lee JH. Novel next generation sequencing panel method for the multiple detection and identification of foodborne pathogens in agricultural wastewater. Front Microbiol 2023; 14:1179934. [PMID: 37520347 PMCID: PMC10374199 DOI: 10.3389/fmicb.2023.1179934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Accepted: 06/19/2023] [Indexed: 08/01/2023] Open
Abstract
Detecting and identifying the origins of foodborne pathogen outbreaks is a challenging. The Next-Generation Sequencing (NGS) panel method offers a potential solution by enabling efficient screening and identification of various bacteria in one reaction. In this study, new NGS panel primer sets that target 18 specific virulence factor genes from six target pathogens (Bacillus cereus, Yersinia enterocolitica, Staphylococcus aureus, Vibrio cholerae, Vibrio parahaemolyticus, and Vibrio vulnificus) were developed and optimized. The primer sets were validated for specificity and selectivity through singleplex PCR, confirming the expected amplicon size. Crosscheck and multiplex PCR showed no interference in the primer set or pathogenic DNA mixture. The NGS panel analysis of spiked water samples detected all 18 target genes in a single reaction, with pathogen concentrations ranging from 108 to 105 colony-forming units (CFUs) per target pathogen. Notably, the total sequence read counts from the virulence factor genes showed a positive association with the CFUs per target pathogen. However, the method exhibited relatively low sensitivity and occasional false positive results at low pathogen concentrations of 105 CFUs. To validate the detection and identification results, two sets of quantitative real-time PCR (qPCR) analyses were independently performed on the same spiked water samples, yielding almost the same efficiency and specificity compared to the NGS panel analysis. Comparative statistical analysis and Spearman correlation analysis further supported the similarity of the results by showing a negative association between the NGS panel sequence read counts and qPCR cycle threshold (Ct) values. To enhance NGS panel analysis for better detection, optimization of primer sets and real-time NGS sequencing technology are essential. Nonetheless, this study provides valuable insights into applying NGS panel analysis for multiple foodborne pathogen detection, emphasizing its potential in ensuring food safety.
Collapse
Affiliation(s)
- Dong-Geun Park
- Department of Food and Animal Biotechnology, Seoul National University, Seoul, Republic of Korea
- Department of Agricultural Biotechnology, Seoul National University, Seoul, Republic of Korea
- Research Institute of Agriculture and Life Sciences, Seoul National University, Seoul, Republic of Korea
- Center for Food and Bioconvergence, Seoul National University, Seoul, Republic of Korea
| | - Joon-Gi Kwon
- Department of Food and Animal Biotechnology, Seoul National University, Seoul, Republic of Korea
- Department of Agricultural Biotechnology, Seoul National University, Seoul, Republic of Korea
- Research Institute of Agriculture and Life Sciences, Seoul National University, Seoul, Republic of Korea
- Center for Food and Bioconvergence, Seoul National University, Seoul, Republic of Korea
| | - Eun-Su Ha
- Research and Development Center, Sanigen Co., Ltd, Anyang, Republic of Korea
| | - Byungcheol Kang
- Research and Development Center, Sanigen Co., Ltd, Anyang, Republic of Korea
| | - Iseul Choi
- Research and Development Center, Sanigen Co., Ltd, Anyang, Republic of Korea
| | - Jeong-Eun Kwak
- Department of Food and Animal Biotechnology, Seoul National University, Seoul, Republic of Korea
- Department of Agricultural Biotechnology, Seoul National University, Seoul, Republic of Korea
- Research Institute of Agriculture and Life Sciences, Seoul National University, Seoul, Republic of Korea
- Center for Food and Bioconvergence, Seoul National University, Seoul, Republic of Korea
| | - Jinho Choi
- Research and Development Center, Sanigen Co., Ltd, Anyang, Republic of Korea
| | - Woojung Lee
- Division of Food Microbiology, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Cheongju, Republic of Korea
| | - Seung Hwan Kim
- Division of Food Microbiology, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Cheongju, Republic of Korea
| | - Soon Han Kim
- Division of Food Microbiology, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Cheongju, Republic of Korea
| | - Jeongwoong Park
- Research and Development Center, Sanigen Co., Ltd, Anyang, Republic of Korea
| | - Ju-Hoon Lee
- Department of Food and Animal Biotechnology, Seoul National University, Seoul, Republic of Korea
- Department of Agricultural Biotechnology, Seoul National University, Seoul, Republic of Korea
- Research Institute of Agriculture and Life Sciences, Seoul National University, Seoul, Republic of Korea
- Center for Food and Bioconvergence, Seoul National University, Seoul, Republic of Korea
| |
Collapse
|
2
|
Confinement of defect-rich bimetallic In 2O 3/CeO 2 nanocrystals in mesoporous nitrogen-doped carbon as a sensitive platform for photoelectrochemical aptasensing of Escherichia coli. Anal Chim Acta 2023; 1248:340893. [PMID: 36813455 DOI: 10.1016/j.aca.2023.340893] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 01/14/2023] [Accepted: 01/24/2023] [Indexed: 01/26/2023]
Abstract
The sensitive determination of food-borne pathogens from food products is essential to ensure food safety and to protect people's health. Herein, a novel photoelectrochemical (PEC) aptasensor was manufactured based on defect-rich bimetallic cerium/indium oxide nanocrystals confined in mesoporous nitrogen-doped carbon (denoted as In2O3/CeO2@mNC) for sensitively detecting Escherichia coli (E. coli) from real samples. A new cerium-based polymer-metal-organic framework [polyMOF(Ce)] was synthesized using polyether polymer containing 1,4-benzenedicarboxylic acid unit (L8) as ligand, trimesic acid as co-ligand, and cerium ions as coordination centers. After adsorbing trace indium ions (In3+), the gained polyMOF(Ce)/In3+ complex was calcined at high temperature under nitrogen atmosphere, resulting in the production of a series of defect-rich In2O3/CeO2@mNC hybrids. Benefitting from the advantages of high specific surface area, large pore size, and multiple functionality of polyMOF(Ce), In2O3/CeO2@mNC hybrids showed enhanced visible light absorption ability, separation performance of the photo-generated electrons and holes, promoted electron transfer, as well as the strong bioaffinity toward E. coli-targeted aptamer. Accordingly, the constructed PEC aptasensor illustrated an ultralow detection limit of 1.12 CFU mL-1, remarkably lower than most of the reported E. coli biosensors, along with high stability and selectivity, excellent reproducibility, and expected regeneration ability. The present work provides insight into the construction of a general PEC biosensing strategy based on MOF-based derivatives for the sensitive analysis of food-borne pathogens.
Collapse
|
3
|
Identification of a specific surface epitope of OmpC for Escherichia coli O157:H7 with protein topology facilitated affinity mass spectrometry. Appl Microbiol Biotechnol 2021; 105:6819-6833. [PMID: 34432131 PMCID: PMC8426304 DOI: 10.1007/s00253-021-11511-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 08/04/2021] [Accepted: 08/07/2021] [Indexed: 11/03/2022]
Abstract
Abstract
The goal of this work was to identify the target protein and epitope of a previously reported Escherichia coli O157:H7 (ECO157)–specific monoclonal antibody (mAb) 2G12. mAb 2G12 has shown high specificity for the recovery and detection of ECO157. To achieve this goal, the target protein was first separated by two-dimensional gel electrophoresis (2-DE) and located by Western blot (WB). The protein spots were identified to be the outer membrane protein (Omp) C by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF–MS). After that, the target protein was purified by immunoaffinity chromatography (IAC) and subjected to in situ enzymatic cleavage of the vulnerable peptides. Eight eluted peptides of OmpC identified by liquid chromatography–tandem mass spectrometry (LC–MS/MS) were further mapped onto the homologous protein structure of E. coli OmpC (2IXX). The topology of OmpC showed that three peptides had extracellular loops. Epitope mapping with overlapping peptide library and sequence homology analysis revealed that the epitope consisted of a specific peptide, “LGVING,” and an adjacent conservative peptide, “TQTYNATRVGSLG.” Both peptides loop around the overall structure of the epitope. To test the availability of the epitope when ECO157 was grown under different osmolarity, pH, and nutrition levels, the binding efficacy of mAb 2G12 with ECO157 grown in these conditions was evaluated. Results further demonstrated the good stability of this epitope under potential stressful environmental conditions. In summary, this study revealed that mAb 2G12 targeted one specific and one conservative extracellular loop (peptide) of the OmpC present on ECO157, and the epitope was stable and accessible on ECO157 cells grown in different environment. Key points • OmpC is the target of a recently identified ECO157-specific mAb 2G12. • Eight peptides were identified from the OmpC by using LC–MS/MS. • The specificity of mAb 2G12 is mainly determined by the “LGVING” peptide. Supplementary Information The online version contains supplementary material available at 10.1007/s00253-021-11511-8.
Collapse
|
4
|
Khan S, Akrema, Qazi S, Ahmad R, Raza K, Rahisuddin. In Silico and Electrochemical Studies for a ZnO-CuO-Based Immunosensor for Sensitive and Selective Detection of E. coli. ACS OMEGA 2021; 6:16076-16085. [PMID: 34179653 PMCID: PMC8223399 DOI: 10.1021/acsomega.1c01959] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 06/01/2021] [Indexed: 12/04/2023]
Abstract
Escherichia coli is a harmful Gram-negative bacterium commonly found in the gut of warm-blooded organisms and affects millions of people annually worldwide. In this study, we have synthesized a ZnO-CuO nanocomposite (NC) by a co-precipitation method and characterized the as-synthesized NC using FTIR spectroscopy, XRD, Raman spectroscopy, and FESEM techniques. To fabricate the immunosensor, the ZnO-CuO NC composite was screen-printed on gold-plated electrodes followed by physisorption of the anti-LPS E. coli antibody. The biosensor was optimized for higher specificity and sensitivity. The immunosensor exhibited a high sensitivity (11.04 μA CFU mL-1) with a low detection limit of 2 CFU mL-1 with a redox couple. The improved performance of the immunosensor is attributed to the synergistic effect of the NC and the antilipopolysaccharide antibody against E. coli. The selectivity studies were also carried out with Staphylococcus aureus to assess the specificity of the immunosensor. Testing in milk samples was done by spiking the milk samples with different concentrations of E. coli to check the potential of this immunosensor. We further checked the affinity between ZnO-CuO NC with E. coli LPS and the anti-LPS antibody using molecular docking studies. Atomic charge computation and interaction analyses were performed to support our hypothesis. Our results discern that there is a strong correlation between molecular docking studies and electrochemical characterization. The interaction analysis further displays the strong affinity between the antibody-LPS complex when immobilized with a nanoparticle composite (ZnO-CuO).
Collapse
Affiliation(s)
- Summaiyya Khan
- Department
of Chemistry, Jamia Millia Islamia, New Delhi 110025, India
| | - Akrema
- Department
of Chemistry, Jamia Millia Islamia, New Delhi 110025, India
| | - Sahar Qazi
- Department
of Computer Science, Jamia Millia Islamia, New Delhi 110025, India
| | - Rafiq Ahmad
- Centre
for Nanoscience and Nanotechnology, Jamia
Millia Islamia, New Delhi 110025, India
| | - Khalid Raza
- Department
of Computer Science, Jamia Millia Islamia, New Delhi 110025, India
| | - Rahisuddin
- Department
of Chemistry, Jamia Millia Islamia, New Delhi 110025, India
| |
Collapse
|
5
|
Wang W, Sang Y, Liu J, Liang X, Guo S, Liu L, Yuan Q, Xing C, Pan S, Wang L. Identification of novel monoclonal antibodies targeting the outer membrane protein C and lipopolysaccharides for Escherichia coli O157:H7 detection. J Appl Microbiol 2020; 130:1245-1258. [PMID: 32910517 DOI: 10.1111/jam.14849] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 08/27/2020] [Accepted: 09/02/2020] [Indexed: 12/14/2022]
Abstract
AIMS To identify and evaluate the application of two novel monoclonal antibody (mAb) 2G12 against outer membrane protein (Omp) C and mAb 12B1 targeting the O chain of the lipopolysaccharides (LPS) of Escherichia coli O157:H7 (ECO157). METHODS AND RESULTS The sensitivity and specificity of these two antibodies were evaluated with eight ECO157 strains and 68 untargeted strains. mAb 2G12 and 12B1 had no detectable binding with any of the non-O157 strains at 6·0 log10 CFU per ml, while its high specificity and affinity remained with all ECO157 strains. When a higher level (8·0 log10 CFU per ml) was tested, 2G12 and 12B1 did not react with 82·35 and 97·06% of the non-O157 strains respectively. Based on the pair of two antibodies, the sandwich enzyme-linked immunosorbent assay detected 100% (8/8) of ECO157 strains and none of the non-ECO157 strains. The detection limit of ECO157 strains in pure culture were 4·2 ± 0·2 log10 CFU per ml. When the developed test was applied to artificially inoculated beef samples, the detection limit was 6·0 log10 CFU per gram without enrichment and 1·0 log10 CFU per gram after 12 h of enrichment. CONCLUSIONS The two novel antibodies identified in this study served as great candidates for the recovery, and detection of ECO157 from different environmental and food samples. SIGNIFICANCE AND IMPACT OF THE STUDY ECO157-specific detection was improved by a combination of the novel OmpC mAb and LPS mAb with defined target antigen and good specificity.
Collapse
Affiliation(s)
- W Wang
- Jiangsu Key Laboratory of Marine Bioresources and Environment, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Jiangsu Key Laboratory of Marine Biotechnology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China
| | - Y Sang
- Jiangsu Key Laboratory of Marine Bioresources and Environment, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Jiangsu Key Laboratory of Marine Biotechnology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China
| | - J Liu
- Jiangsu Key Laboratory of Marine Bioresources and Environment, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Jiangsu Key Laboratory of Marine Biotechnology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China
| | - X Liang
- Jiangsu Key Laboratory of Marine Bioresources and Environment, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Jiangsu Key Laboratory of Marine Biotechnology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China
| | - S Guo
- Jiangsu Key Laboratory of Marine Bioresources and Environment, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Jiangsu Key Laboratory of Marine Biotechnology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China
| | - L Liu
- Jiangsu Key Laboratory of Marine Bioresources and Environment, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Jiangsu Key Laboratory of Marine Biotechnology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China
| | - Q Yuan
- Jiangsu Key Laboratory of Marine Bioresources and Environment, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Jiangsu Key Laboratory of Marine Biotechnology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China
| | - C Xing
- School of Food Science and Engineering, Nanjing University of Finance & Economics, Nanjing, Jiangsu, P.R. China
| | - S Pan
- Jiangsu Key Laboratory of Marine Bioresources and Environment, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Jiangsu Key Laboratory of Marine Biotechnology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China.,Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, Jiangsu, P.R. China
| | - L Wang
- Department of Food Science and Technology, University of California Davis, Davis, CA, USA
| |
Collapse
|
6
|
To CZ, Bhunia AK. Three Dimensional Vero Cell-Platform for Rapid and Sensitive Screening of Shiga-Toxin Producing Escherichia coli. Front Microbiol 2019; 10:949. [PMID: 31134009 PMCID: PMC6514307 DOI: 10.3389/fmicb.2019.00949] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2019] [Accepted: 04/15/2019] [Indexed: 01/27/2023] Open
Abstract
Shiga-toxin producing Escherichia coli (STEC) is a serious public health concern. Current Vero cell assay, although sensitive, is lengthy and requires 48-72 h to assess STEC presence in a sample. In this study, we investigated if Vero cells in a three-dimensional (3D) platform would provide improved sensitivity for rapid screening of STEC. Vero cells (epithelial kidney cell line) were grown as a monolayer (2D) or in a collagen-matrix (3D) and exposed to Shiga-toxin (Stx) preparation or STEC cells that were pre-exposed to antibiotics (mitomycin C, ciprofloxacin, or polymyxin B) for toxin induction. Lactate dehydrogenase (LDH) release from Vero cells was used as a biomarker for cytotoxicity. Modified tryptic soy broth (mTSB) as enrichment broth containing mitomycin C (2 μg/ml) or ciprofloxacin (100 ng/ml) significantly induced Stx production, which was further confirmed by the dot-immunoblot assay. The 3D Vero platform detected STEC after 6 h post-infection with cytotoxicity values ranging from 33 to 79%, which is considerably faster than the traditional 2D platform, when tested with STEC. The cytotoxicity for non-Stx producing bacteria, Salmonella, Listeria, Citrobacter, Serratia, and Hafnia was found to be below the cytotoxicity cutoff value of 15%. The detection limit for the 3D Vero cell assay was estimated to be 107 CFU/ml for bacteria and about 32 ng/ml for Stx in 6 h. STEC-inoculated ground beef samples (n = 27) resulted in 38-46% cytotoxicity, and the bacterial isolates (n = 42) from ground beef samples were further confirmed to be stx1 and stx2 positive in a multiplex PCR yielding a very low false-positive result. This 3D cell-based screening assay relies on mammalian cell pathogen interaction that can complement other molecular techniques for the detection of cell-free Stx or STEC cells from food samples for early detection and prevention.
Collapse
Affiliation(s)
- Celina Z. To
- Molecular Food Microbiology Laboratory, Department of Food Science, Purdue University, West Lafayette, IN, United States
| | - Arun K. Bhunia
- Molecular Food Microbiology Laboratory, Department of Food Science, Purdue University, West Lafayette, IN, United States
- Department of Comparative Pathobiology, Purdue University, West Lafayette, IN, United States
- Purdue Institute of Inflammation, Immunology and Infectious Disease, Purdue University, West Lafayette, IN, United States
| |
Collapse
|
7
|
An impedimetric biosensor for E. coli O157:H7 based on the use of self-assembled gold nanoparticles and protein G. Mikrochim Acta 2019; 186:169. [DOI: 10.1007/s00604-019-3282-3] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Accepted: 01/23/2019] [Indexed: 10/27/2022]
|
8
|
Xu H, Tang F, Dai J, Wang C, Zhou X. Ultrasensitive and rapid count of Escherichia coli using magnetic nanoparticle probe under dark-field microscope. BMC Microbiol 2018; 18:100. [PMID: 30176804 PMCID: PMC6122661 DOI: 10.1186/s12866-018-1241-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 08/20/2018] [Indexed: 12/05/2022] Open
Abstract
Background Escherichia coli (E. coli) is one of the best-known zoonotic bacterial species, which pathogenic strain can cause infections in humans and animals. However, existing technologies or methods are deficient for quickly on-site identifying infection of E. coli before they breakout. Herein, we present an ultrasensitive and on-site method for counting E. coli using magnetic nanoparticle (MNP) probe under a dark-field in 30 min. Results The antibodies functionalized MNP, binding to E. coli to form a golden ring-like structure under a dark-field microscope, allowing for counting E. coli. This method via counting MNP-conjugated E. coli under dark-field microscope demonstrated the sensitivity of 6 CFU/μL for E. coli detection. Importantly, due to the advantages such as time-saving (only 30 min) and almost free of instrument (only require a portable microscope), our MNP-labeled dark-field counting strategy has the potential of being a universal tool for on-site quantifying a variety of pathogens with size ranges from a few hundreds of nanometers to a few micrometers. Conclusion In summary, the MNP-labeled dark-field counting strategy is a rapid, simple, sensitive as well as low-cost assay strategy, which has the potential of being a universal tool for on-site quantification of micrometer-size pathogens like E. coli. Electronic supplementary material The online version of this article (10.1186/s12866-018-1241-5) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Haixu Xu
- Institute of Comparative Medicine, Jiangsu Co-innovation Center for Prevention and Control of Important Animal Infectious Diseases and Zoonoses, Joint International Research Laboratory of Agriculture and Agri-Product Safety, the Ministry of Education of China, Yangzhou University, Yangzhou, 225009, China
| | - Fang Tang
- Key Laboratory of Animal Bacteriology, Ministry of Agriculture, College of veterinary medicine, Nanjing Agricultural University, Nanjing, 210095, China
| | - Jianjun Dai
- Key Laboratory of Animal Bacteriology, Ministry of Agriculture, College of veterinary medicine, Nanjing Agricultural University, Nanjing, 210095, China
| | - Chengming Wang
- Department of Pathobiology, College of Veterinary Medicine, Auburn University, 268 Greene Hall, 1130 Wire Rd, Auburn, AL, 36849-5519, USA
| | - Xin Zhou
- Institute of Comparative Medicine, Jiangsu Co-innovation Center for Prevention and Control of Important Animal Infectious Diseases and Zoonoses, Joint International Research Laboratory of Agriculture and Agri-Product Safety, the Ministry of Education of China, Yangzhou University, Yangzhou, 225009, China.
| |
Collapse
|
9
|
Neethirajan S, Ahmed SR, Chand R, Buozis J, Nagy É. Recent Advances in Biosensor Development for Foodborne Virus Detection. Nanotheranostics 2017; 1:272-295. [PMID: 29071193 PMCID: PMC5646734 DOI: 10.7150/ntno.20301] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2017] [Accepted: 05/07/2017] [Indexed: 11/05/2022] Open
Abstract
Outbreaks of foodborne diseases related to fresh produce have been increasing in North America and Europe. Viral foodborne pathogens are poorly understood, suffering from insufficient awareness and surveillance due to the limits on knowledge, availability, and costs of related technologies and devices. Current foodborne viruses are emphasized and newly emerging foodborne viruses are beginning to attract interest. To face current challenges regarding foodborne pathogens, a point-of-care (POC) concept has been introduced to food testing technology and device. POC device development involves technologies such as microfluidics, nanomaterials, biosensors and other advanced techniques. These advanced technologies, together with the challenges in developing foodborne virus detection assays and devices, are described and analysed in this critical review. Advanced technologies provide a path forward for foodborne virus detection, but more research and development will be needed to provide the level of manufacturing capacity required.
Collapse
Affiliation(s)
- Suresh Neethirajan
- BioNano Laboratory, School of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada
| | - Syed Rahin Ahmed
- BioNano Laboratory, School of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada
| | - Rohit Chand
- BioNano Laboratory, School of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada
| | - John Buozis
- BioNano Laboratory, School of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada
| | - Éva Nagy
- Department of Pathobiology, Ontario Veterinary College, University of Guelph, Guelph, ON N1G 2W1, Canada
| |
Collapse
|
10
|
Pandey A, Gurbuz Y, Ozguz V, Niazi JH, Qureshi A. Graphene-interfaced electrical biosensor for label-free and sensitive detection of foodborne pathogenic E. coli O157:H7. Biosens Bioelectron 2016; 91:225-231. [PMID: 28012318 DOI: 10.1016/j.bios.2016.12.041] [Citation(s) in RCA: 71] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2016] [Revised: 12/01/2016] [Accepted: 12/15/2016] [Indexed: 01/07/2023]
Abstract
E. coli O157:H7 is an enterohemorrhagic bacteria responsible for serious foodborne outbreaks that causes diarrhoea, fever and vomiting in humans. Recent foodborne E. coli outbreaks has left a serious concern to public health. Therefore, there is an increasing demand for a simple, rapid and sensitive method for pathogen detection in contaminated foods. In this study, we developed a label-free electrical biosensor interfaced with graphene for sensitive detection of pathogenic bacteria. This biosensor was fabricated by interfacing graphene with interdigitated microelectrodes of capacitors that were biofunctionalized with E. coli O157:H7 specific antibodies for sensitive pathogenic bacteria detection. Here, graphene nanostructures on the sensor surface provided superior chemical properties such as high carrier mobility and biocompatibility with antibodies and bacteria. The sensors transduced the signal based on changes in dielectric properties (capacitance) through (i) polarization of captured cell-surface charges, (ii) cells' internal bioactivity, (iii) cell-wall's electronegativity or dipole moment and their relaxation and (iv) charge carrier mobility of graphene that modulated the electrical properties once the pathogenic E. coli O157:H7 captured on the sensor surface. Sensitive capacitance changes thus observed with graphene based capacitors were specific to E. coli O157:H7 strain with a sensitivity as low as 10-100 cells/ml. The proposed graphene based electrical biosensor provided advantages of speed, sensitivity, specificity and in-situ bacterial detection with no chemical mediators, represents a versatile approach for detection of a wide variety of other pathogens.
Collapse
Affiliation(s)
- Ashish Pandey
- Sabanci University Nanotechnology Research and Application Center, Orta Mah., 34956 Istanbul, Turkey
| | - Yasar Gurbuz
- Faculty of Engineering and Natural Science, Sabanci University, Orhanli, Tuzla, 34956 Istanbul, Turkey
| | - Volkan Ozguz
- Sabanci University Nanotechnology Research and Application Center, Orta Mah., 34956 Istanbul, Turkey
| | - Javed H Niazi
- Sabanci University Nanotechnology Research and Application Center, Orta Mah., 34956 Istanbul, Turkey.
| | - Anjum Qureshi
- Sabanci University Nanotechnology Research and Application Center, Orta Mah., 34956 Istanbul, Turkey.
| |
Collapse
|
11
|
Wu L, Song Y, Luan T, Ma L, Su L, Wang S, Yan X. Specific detection of live Escherichia coli O157:H7 using tetracysteine-tagged PP01 bacteriophage. Biosens Bioelectron 2016; 86:102-108. [PMID: 27341136 DOI: 10.1016/j.bios.2016.06.041] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2016] [Revised: 05/13/2016] [Accepted: 06/14/2016] [Indexed: 12/26/2022]
Abstract
Sensitive and rapid detection of Escherichia coli O157:H7, one of the most notorious bacterial pathogens, is urgently needed for public health protection. Yet, the existing methods are either lack of speed or limited in discriminating viable and dead cells. Using a recombinant bacteriophage, here we report the development of a rapid and sensitive method for live E. coli O157:H7 detection. First, the wild-type PP01 phage was engineered with a tetracysteine (TC)-tag fused with the small outer capsid (SOC) protein. Then, this PP01-TC phage was used to inoculate bacterial sample for 30min. Specific infection and rapid replication of PP01-TC phage in viable E. coli O157:H7 host cell yields a large number of progeny phages with capsids displaying TC tags that can be fluorescently labeled by a membrane permeable biarsenical dye (FlAsH). The bright green fluorescence of single E. coli O157:H7 cells can be readily detected by flow cytometry (FCM) and fluorescence microscopy. High specificity of the assay was verified with seven other bacterial strains. Practical application in E. coli O157:H7 detection in drinks was successfully demonstrated with artificially contaminated 100% apple juice. In less than three hours (including sample preconcentration) and with 40mL of sample volume, as low as 1cfu/mL E. coli O157:H7 can be detected in the presence of large excess of other nontarget bacteria via fluorescence microscopic measurement. The as-developed TC-PP01-FlAsH approach shows a great potential in the safeguard of liquid food products by providing rapid, sensitive, and specific detection of live E. coli O157:H7.
Collapse
Affiliation(s)
- Lina Wu
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory for Chemical Biology of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005, PR China
| | - Yiyi Song
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory for Chemical Biology of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005, PR China
| | - Tian Luan
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory for Chemical Biology of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005, PR China
| | - Ling Ma
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory for Chemical Biology of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005, PR China
| | - Liuqin Su
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory for Chemical Biology of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005, PR China
| | - Shuo Wang
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory for Chemical Biology of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005, PR China
| | - Xiaomei Yan
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory for Chemical Biology of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005, PR China.
| |
Collapse
|
12
|
Barreiros dos Santos M, Azevedo S, Agusil JP, Prieto-Simón B, Sporer C, Torrents E, Juárez A, Teixeira V, Samitier J. Label-free ITO-based immunosensor for the detection of very low concentrations of pathogenic bacteria. Bioelectrochemistry 2016; 101:146-52. [PMID: 25460610 DOI: 10.1016/j.bioelechem.2014.09.002] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2014] [Revised: 09/20/2014] [Accepted: 09/21/2014] [Indexed: 01/24/2023]
Abstract
Here we describe the fabrication of a highly sensitive and label-free ITO-based impedimetric immunosensor for the detection of pathogenic bacteria Escherichia coli O157:H7. Anti-E. coli antibodies were immobilized onto ITO electrodes using a simple, robust and direct methodology. First, the covalent attachment of epoxysilane on the ITO surface was demonstrated by Atomic Force Microscopy and cyclic voltammetry. The immobilization of antibody on the epoxysilane layer was quantified by Optical Waveguide Lightmode Spectroscopy, obtaining a mass variation of 12 ng cm(− 2) (0.08 pmol cm(− 2)). Microcontact printing and fluorescence microscopy were used to demonstrate the specific binding of E. coli O157:H7 to the antibody-patterned surface. We achieved a ratio of 1:500 Salmonella typhimurium/E. coli O157:H7, thus confirming the selectivity of the antibodies and efficiency of the functionalization procedure. Finally, the detection capacity of the ITO-based immunosensor was evaluated by Electrochemical Impedance Spectroscopy. A very low limit of detection was obtained (1 CFU mL(− 1)) over a large linear working range (10–10(6) CFU mL(− 1)). The specificity of the impedimetric immunosensor was also examined. Less than 20% of non-specific bacteria (S. typhimurium and E. coli K12) was observed. Our results reveal the applicability of ITO for the development of highly sensitive and selective impedimetric immunosensors.
Collapse
|
13
|
Li Z, Fu Y, Fang W, Li Y. Electrochemical Impedance Immunosensor Based on Self-Assembled Monolayers for Rapid Detection of Escherichia coli O157:H7 with Signal Amplification Using Lectin. SENSORS 2015; 15:19212-24. [PMID: 26251911 PMCID: PMC4570367 DOI: 10.3390/s150819212] [Citation(s) in RCA: 66] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2015] [Revised: 07/10/2015] [Accepted: 07/14/2015] [Indexed: 12/30/2022]
Abstract
Escherichia coli O157:H7 is a predominant foodborne pathogen with severe pathogenicity, leading to increasing attention given to rapid and sensitive detection. Herein, we propose an impedance biosensor using new kinds of screen-printed interdigitated microelectrodes (SPIMs) and wheat germ agglutinin (WGA) for signal amplification to detect E. coli O157:H7 with high sensitivity and time-efficiency. The SPIMs integrate the high sensitivity and short response time of the interdigitated electrodes and the low cost of the screen-printed electrodes. Self-assembling of bi-functional 3-dithiobis-(sulfosuccinimidyl-propionate) (DTSP) on the SPIMs was investigated and was proved to be able to improve adsorption quantity and stability of biomaterials. WGA was further adopted to enhance the signal taking advantage of the abundant lectin-binding sites on the bacteria surface. The immunosensor exhibited a detection limit of 102 cfu·mL−1, with a linear detection range from 102 to 107 cfu·mL−1 (r2 = 0.98). The total detection time was less than 1 h, showing its comparable sensitivity and rapid response. Furthermore, the low cost of one SPIM significantly reduced the detection cost of the biosensor. The biosensor may have great promise in food safety analysis and lead to a portable biosensing system for routine monitoring of foodborne pathogens.
Collapse
Affiliation(s)
- Zhanming Li
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China.
| | - Yingchun Fu
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China.
| | - Weihuan Fang
- College of Animal Science, Zhejiang University, Hangzhou 310058, China.
| | - Yanbin Li
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China.
- Department of Biological & Agricultural Engineering, University of Arkansas, Fayetteville, AR 72701, USA.
| |
Collapse
|
14
|
Terao Y, Takeshita K, Nishiyama Y, Morishita N, Matsumoto T, Morimatsu F. Promising Nucleic Acid Lateral Flow Assay Plus PCR for Shiga Toxin-Producing Escherichia coli. J Food Prot 2015; 78:1560-8. [PMID: 26219371 DOI: 10.4315/0362-028x.jfp-14-495] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Shiga toxin (Stx)-producing Escherichia coli (STEC) is a frequent cause of foodborne infections, and methods for rapid and reliable detection of STEC are needed. A nucleic acid lateral flow assay (NALFA) plus PCR was evaluated for detecting STEC after enrichment. When cell suspensions of 45 STEC strains, 14 non-STEC strains, and 13 non-E. coli strains were tested with the NALFA plus PCR, all of the STEC strains yielded positive results, and all of the non-STEC and non-E. coli strains yielded negative results. The lower detection limit for the STEC strains ranged from 0.1 to 1 pg of genomic DNA (about 20 to 200 CFU) per test, and the NALFA plus PCR was able to detect Stx1- and Stx2-producing E. coli strains with similar sensitivities. The ability of the NALFA plus PCR to detect STEC in enrichment cultures of radish sprouts, tomato, raw ground beef, and beef liver inoculated with 10-fold serially diluted STEC cultures was comparable to that of a real-time PCR assay (at a level of 100 to 100,000 CFU/ml in enrichment culture). The bacterial inoculation test in raw ground beef revealed that the lower detection limit of the NALFA plus PCR was also comparable to that obtained with a real-time PCR assay that followed the U.S. Department of Agriculture guidelines. Although further evaluation is required, these results suggest that the NALFA plus PCR is a specific and sensitive method for detecting STEC in a food manufacturing plant.
Collapse
Affiliation(s)
- Yoshitaka Terao
- R&D Center, NH Foods Ltd., 3-3 Midorigahara, Tsukuba, Ibaraki 300-2646, Japan.
| | - Kana Takeshita
- R&D Center, NH Foods Ltd., 3-3 Midorigahara, Tsukuba, Ibaraki 300-2646, Japan
| | - Yasutaka Nishiyama
- R&D Center, NH Foods Ltd., 3-3 Midorigahara, Tsukuba, Ibaraki 300-2646, Japan
| | - Naoki Morishita
- R&D Center, NH Foods Ltd., 3-3 Midorigahara, Tsukuba, Ibaraki 300-2646, Japan
| | - Takashi Matsumoto
- R&D Center, NH Foods Ltd., 3-3 Midorigahara, Tsukuba, Ibaraki 300-2646, Japan
| | - Fumiki Morimatsu
- R&D Center, NH Foods Ltd., 3-3 Midorigahara, Tsukuba, Ibaraki 300-2646, Japan
| |
Collapse
|
15
|
Baker CA, Rubinelli PM, Park SH, Ricke SC. Immuno-based detection of Shiga toxin-producing pathogenic Escherichia coli in food – A review on current approaches and potential strategies for optimization. Crit Rev Microbiol 2015; 42:656-75. [DOI: 10.3109/1040841x.2015.1009824] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Christopher A. Baker
- Department of Food Science, Center for Food Safety, University of Arkansas, Fayetteville, AR, USA
| | - Peter M. Rubinelli
- Department of Food Science, Center for Food Safety, University of Arkansas, Fayetteville, AR, USA
| | - Si Hong Park
- Department of Food Science, Center for Food Safety, University of Arkansas, Fayetteville, AR, USA
| | - Steven C. Ricke
- Department of Food Science, Center for Food Safety, University of Arkansas, Fayetteville, AR, USA
| |
Collapse
|
16
|
Ghafar-Zadeh E. Wireless integrated biosensors for point-of-care diagnostic applications. SENSORS 2015; 15:3236-61. [PMID: 25648709 PMCID: PMC4367357 DOI: 10.3390/s150203236] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/28/2014] [Accepted: 12/03/2014] [Indexed: 11/16/2022]
Abstract
Recent advances in integrated biosensors, wireless communication and power harvesting techniques are enticing researchers into spawning a new breed of point-of-care (POC) diagnostic devices that have attracted significant interest from industry. Among these, it is the ones equipped with wireless capabilities that drew our attention in this review paper. Indeed, wireless POC devices offer a great advantage, that of the possibility of exerting continuous monitoring of biologically relevant parameters, metabolites and other bio-molecules, relevant to the management of various morbid diseases such as diabetes, brain cancer, ischemia, and Alzheimer's. In this review paper, we examine three major categories of miniaturized integrated devices, namely; the implantable Wireless Bio-Sensors (WBSs), the wearable WBSs and the handheld WBSs. In practice, despite the aforesaid progress made in developing wireless platforms, early detection of health imbalances remains a grand challenge from both the technological and the medical points of view. This paper addresses such challenges and reports the state-of-the-art in this interdisciplinary field.
Collapse
Affiliation(s)
- Ebrahim Ghafar-Zadeh
- Department of Electrical Engineering and Computer Sciences, Lassonde School of Engineering, York University, Toronto, ON M3J1P3, Canada.
| |
Collapse
|
17
|
Wang J, Xu Y, Yau ST. Mediatorless Immunoassay with Voltage-Controlled Intrinsic Amplification for Ultrasensitive and Rapid Detection of Microorganism Pathogens. ChemElectroChem 2014. [DOI: 10.1002/celc.201300180] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
18
|
Huang CJ, Knoll W, Sessitsch A, Dostalek J. SPR bacterial pathogen biosensor: the importance of fluidic conditions and probing depth. Talanta 2014; 122:166-71. [PMID: 24720979 DOI: 10.1016/j.talanta.2014.01.022] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2013] [Revised: 01/13/2014] [Accepted: 01/20/2014] [Indexed: 11/26/2022]
Abstract
The sensitivity of surface plasmon resonance (SPR) biosensor technology for detection of bacterial analytes is investigated as a function of (a) sample flow conditions and (b) depth of probing electromagnetic field. These parameters are extremely important as such analytes exhibit large (of around micrometer) size which significantly hinders their diffusion-driven transfer from a liquid sample to the sensor and their subsequent specific capture by attached recognition elements. This is due to small diffusion coefficient and strong shear stress that decreases the stability of bonds between the bacterium specific epitope and recognition elements immobilized at the sensor surface. The importance of accurate control of sample flow conditions and probing depth in order to maximize SPR sensor response is experimentally demonstrated and supported by an analytical theory. The tuning of the probing depth of surface plasmon evanescent field to match the size of the target analyte is pursued by using long range surface plasmons.
Collapse
Affiliation(s)
- Chun Jen Huang
- Graduate Institute of BioMedical Engineering, National Central University, (32001) No. 300, Jhongda Rd., Jhongli City, Taoyuan County 320, Taiwan
| | - Wolfgang Knoll
- AIT - Austrian Institute of Technology, BioSensor Technologies, Muthgasse 11, 1190 Vienna, Austria
| | - Angela Sessitsch
- AIT Austrian Institute of Technology, Bioresources Unit, Konrad-Lorenz-straße 24, 3430 Tulln, Austria
| | - Jakub Dostalek
- AIT - Austrian Institute of Technology, BioSensor Technologies, Muthgasse 11, 1190 Vienna, Austria.
| |
Collapse
|
19
|
Feng M, Yong Q, Wang W, Kuang H, Wang L, Xu C. Development of a monoclonal antibody-based ELISA to detectEscherichia coliO157:H7. FOOD AGR IMMUNOL 2013. [DOI: 10.1080/09540105.2012.716026] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
|
20
|
Kim WJ, Kim S, Kim AR, Yoo DJ. Direct Detection System for Escherichia coli Using Au–Ag Alloy Microchips. Ind Eng Chem Res 2013. [DOI: 10.1021/ie3022797] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- Wan-Joong Kim
- Biosensor Research Team, Electronics and Telecommunications Research Institute, Daejeon 305-700,
Republic of Korea
| | - Sanghee Kim
- Department
of Mechanical Systems Engineering, Hansung University, Seoul 136-792, Republic of Korea
| | | | | |
Collapse
|
21
|
Highly sensitive detection of pathogen Escherichia coli O157:H7 by electrochemical impedance spectroscopy. Biosens Bioelectron 2013; 45:174-80. [PMID: 23500360 DOI: 10.1016/j.bios.2013.01.009] [Citation(s) in RCA: 104] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2012] [Revised: 12/28/2012] [Accepted: 01/07/2013] [Indexed: 01/25/2023]
Abstract
The presence of enterohemorrhagic Escherichia coli bacteria in food can cause serious foodborne disease outbreaks. Early detection and identification of these pathogens is extremely important for public health and safety. Here we present a highly sensitive label-free immunosensor for the detection of pathogenic E. coli O157:H7. Anti-E. coli antibodies were covalently immobilised onto gold electrodes via a self-assembled monolayer (SAM) of mercaptohexadecanoic acid and the pathogenic bacteria were detected by electrochemical impedance spectroscopy (EIS). Surface Plasmon Resonance (SPR) was used to monitor the antibody immobilisation protocol and antibody patterned surfaces were used to demonstrate the specificity of the antibody coated surfaces against the pathogenic bacteria. The immunosensor showed a very low limit of detection (2CFU/mL) and a large linear range (3 × 10-3 × 10(4)CFU/mL). Finally, the selectivity of the sensor was demonstrated and no significant adsorption of Salmonella typhimurium was observed.
Collapse
|
22
|
Yoon JY, Kim B. Lab-on-a-chip pathogen sensors for food safety. SENSORS (BASEL, SWITZERLAND) 2012; 12:10713-41. [PMID: 23112625 PMCID: PMC3472853 DOI: 10.3390/s120810713] [Citation(s) in RCA: 87] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/09/2012] [Revised: 06/28/2012] [Accepted: 07/04/2012] [Indexed: 02/08/2023]
Abstract
There have been a number of cases of foodborne illness among humans that are caused by pathogens such as Escherichia coli O157:H7, Salmonella typhimurium, etc. The current practices to detect such pathogenic agents are cell culturing, immunoassays, or polymerase chain reactions (PCRs). These methods are essentially laboratory-based methods that are not at all real-time and thus unavailable for early-monitoring of such pathogens. They are also very difficult to implement in the field. Lab-on-a-chip biosensors, however, have a strong potential to be used in the field since they can be miniaturized and automated; they are also potentially fast and very sensitive. These lab-on-a-chip biosensors can detect pathogens in farms, packaging/processing facilities, delivery/distribution systems, and at the consumer level. There are still several issues to be resolved before applying these lab-on-a-chip sensors to field applications, including the pre-treatment of a sample, proper storage of reagents, full integration into a battery-powered system, and demonstration of very high sensitivity, which are addressed in this review article. Several different types of lab-on-a-chip biosensors, including immunoassay- and PCR-based, have been developed and tested for detecting foodborne pathogens. Their assay performance, including detection limit and assay time, are also summarized. Finally, the use of optical fibers or optical waveguide is discussed as a means to improve the portability and sensitivity of lab-on-a-chip pathogen sensors.
Collapse
Affiliation(s)
- Jeong-Yeol Yoon
- Department of Agricultural and Biosystems Engineering, the University of Arizona, Tucson, AZ 85721, USA.
| | | |
Collapse
|
23
|
Park MK, Oh JH. Rapid detection of E. coli O157:H7 on turnip greens using a modified gold biosensor combined with light microscopic imaging system. J Food Sci 2012; 77:M127-34. [PMID: 22251215 DOI: 10.1111/j.1750-3841.2011.02537.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
This research aims to demonstrate the feasibility of a modified gold biosensor to detect E. coli O157:H7 in leafy turnip greens. The gold biosensor was modified with dithiobis-succinimidyl propionate (DSP) and/or protein A or G. The gold biosensor modified with DSP (Gold-DSP) was combined with a light microscopic imaging system (LMIS). The optimal concentration and specificity of anti-E. coli O15 polyclonal antibodies (pAbs) on the biosensor were determined. The reliability of Gold-DSP biosensor was investigated by determining the sensitivity, specificity, and limit of detection (LOD) of the Gold-DSP combined with LMIS. The Gold-DSP combined with LMIS was applied to turnip greens for E. coli O157:H7 detection. The modification of Gold biosensor with DSP significantly increased the detected number of E. coli O157:H7. The specificity of pAbs was sufficient to react with target E. coli O157:H7 among the tested bacterial culture. The optimum concentration of pAbs was determined as 200 μg/mL. The sensitivity, specificity, and LOD of Gold-DSP combined with LMIS were determined as 100%, 90%, and 10(3) CFU/25 mm(2) , respectively. When applied to turnip greens, the Gold-DSP combined with LMIS could detect 2641 ± 394 and 15383 ± 3853 cell/mm(2) with the initial concentrations of 10(1) and 10(2) CFU/25 g turnip greens, respectively, after 10 h-enrichment. Overall, this research suggested that the Gold-DSP combined with LMIS could be used to detect E. coli O157:H7 on turnip greens qualitatively and quantitatively.
Collapse
Affiliation(s)
- Mi-Kyung Park
- Materials Research and Education Center, Auburn Univ, 275 Wilmore Labs, Auburn, AL 36830, USA
| | | |
Collapse
|
24
|
Adhikari MD, Panda BR, Vudumula U, Chattopadhyay A, Ramesh A. A facile method for estimating viable bacterial cells in solution based on “subtractive-aggregation” of gold nanoparticles. RSC Adv 2012. [DOI: 10.1039/c1ra01023a] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
25
|
LIU P, MIZUE H, FUJIHARA K, KOBAYASHI H, KAMIKADO H, TANAKA T, HONJOH KI, MIYAMOTO T. A New Rapid Real-Time PCR Method for Detection of Listeria monocytogenes Targeting the hlyA Gene. FOOD SCIENCE AND TECHNOLOGY RESEARCH 2012. [DOI: 10.3136/fstr.18.47] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
26
|
Lee YJ, Han SR, Maeng JS, Cho YJ, Lee SW. In vitro selection of Escherichia coli O157:H7-specific RNA aptamer. Biochem Biophys Res Commun 2011; 417:414-20. [PMID: 22166202 DOI: 10.1016/j.bbrc.2011.11.130] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2011] [Accepted: 11/28/2011] [Indexed: 12/23/2022]
Abstract
Escherichia coli (E. coli) O157:H7 is a major foodborne pathogen that causes life-threatening symptoms in humans worldwide. To rapidly and properly identify the pathogen and avoid its toxic effects, ligands which can directly and specifically bind to the virulent E. coli O157:H7 serotype should be identified. In this study, a RNA aptamer-based ligand which can specifically distinguish the pathogen E. coli O157:H7 from others was developed by a subtractive cell-SELEX method. To this end, an RNA library was first incubated with the E. coli K12 strain, and the RNAs binding to the strain were discarded. The precluded RNAs were then used for the selection of O157:H7-specific aptamers. After 6 rounds of the subtractive cell-SELEX process, the selected aptamer was found to specifically bind to the O157:H7 serotype, but not to the K12 strain. This was evidenced by aptamer-immobilized ELISA, real-time PCR analysis, or an aptamer-linked precipitation experiment. Importantly, the isolated RNA aptamer that distinguishes between the virulent serotype and the nonpathogenic strain specifically bound to an O157:H7-specific lipopolysaccharide which includes the O antigen. This novel O157:H7-specific aptamer could be of potential application as a diagnostic ligand against the pathogen-related food borne illness.
Collapse
Affiliation(s)
- Young Ju Lee
- Department of Molecular Biology, Institute of Nanosensor and Biotechnology, Dankook University, Yongin, Republic of Korea
| | | | | | | | | |
Collapse
|
27
|
Li Y, Cheng P, Gong J, Fang L, Deng J, Liang W, Zheng J. Amperometric immunosensor for the detection of Escherichia coli O157:H7 in food specimens. Anal Biochem 2011; 421:227-33. [PMID: 22119072 DOI: 10.1016/j.ab.2011.10.049] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2011] [Revised: 10/25/2011] [Accepted: 10/27/2011] [Indexed: 11/24/2022]
Abstract
A novel, label-free amperometric immunosensor has been developed for the rapid detection of heat-killed Escherichia coli O157:H7 (E. coli O157:H7). This immunosensor was prepared as follows. First, the long-chain, amine-terminated alkanethiol 11-amino-1-undecanethiol hydrochloride (AUT) was self-assembled onto a gold electrode surface to form an ordered, oriented, compact, and stable monolayer possessing -NH(2) functional groups that could immobilize massive gold nanoparticles (GNPs). Next, chitosan-multiwalled carbon nanotubes-SiO(2)/thionine (CHIT-MWNTs-SiO(2)@THI) nanocomposites and GNPs multilayer films were prepared via layer-by-layer (LBL) assembly. The surface area enhancement from the LBL assembly of the multilayer films improves the stability of the immobilized CHIT-MWNTs-SiO(2)@THI. More important, the sensitivity and stability of the immunosensor can be enhanced proportionally to the quantity of the THI mediator immobilized on the electrode surface. Finally, the E. coli O157:H7 antibody (anti-E. coli O157:H7) was covalently bound to the GNP monolayer and its bioactivity was measured by enzyme-linked immunosorbent assay (ELISA). Transmission electron microscopy (TEM) was employed to characterize the morphology of the MWNTs, CHIT-MWNTs, and CHIT-MWNTs-SiO(2)@THI. Under optimal conditions, the calibration curve for heat-killed E. coli O157:H7 has a working range of 4.12×10(2)-4.12×10(5) colony-forming units (CFU)/ml, and the total assay time was less than 45 min.
Collapse
Affiliation(s)
- Yan Li
- Department of Clinical Laboratory Science, College of Medical Laboratory, Third Military Medical University, Chongqing 400038, People's Republic of China
| | | | | | | | | | | | | |
Collapse
|
28
|
Thompson CS, Traynor IM, Fodey TL, Crooks SR, Kennedy DG. Screening method for the detection of a range of nitrofurans in avian eyes by optical biosensor. Anal Chim Acta 2011; 700:177-82. [DOI: 10.1016/j.aca.2010.10.048] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2010] [Revised: 10/27/2010] [Accepted: 10/29/2010] [Indexed: 10/18/2022]
|
29
|
Lamarche P, Tawil N, Khan R, Aliakbar AM, Hassan MH, Chodavarapu VP, Mandeville R. CMOS Conductometric System for Growth Monitoring and Sensing of Bacteria. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2011; 5:223-230. [PMID: 23851473 DOI: 10.1109/tbcas.2010.2089794] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
We present the design and implementation of a prototype complementary metal-oxide semiconductor (CMOS) conductometric integrated circuit (IC) for colony growth monitoring and specific sensing of Escherichia coli (E. coli) bacteria. The detection of E. coli is done by employing T4 bacteriophages as receptor organisms. The conductometric system operates by measuring the resistance of the test sample between the electrodes of a two-electrode electrochemical system (reference electrode and working electrode). The CMOS IC is fabricated in a TSMC 0.35-μm process and uses a current-to-frequency (I to F) conversion circuit to convert the test sample resistance into a digital output modulated in frequency. Pulsewidth control (one-shot circuit) is implemented on-chip to control the pulsewidth of the output digital signal. The novelty in the current work lies in the ability of the CMOS sensor system to monitor very low initial concentrations of bacteria (4×10(2) to 4×10(4) colony forming unit (CFU)/mL). The CMOS system is also used to record the interaction between E. coli and its specific receptor T4 bacteriophage. The prototype CMOS IC consumes an average power of 1.85 mW with a 3.3-V dc power supply.
Collapse
|
30
|
Cevallos-Cevallos JM, Danyluk MD, Reyes-De-Corcuera JI. GC-MS Based Metabolomics for Rapid Simultaneous Detection of Escherichia coli O157:H7, Salmonella Typhimurium, Salmonella Muenchen, and Salmonella Hartford in Ground Beef and Chicken. J Food Sci 2011; 76:M238-46. [DOI: 10.1111/j.1750-3841.2011.02132.x] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
31
|
Sidari R, Caridi A. Methods for Detecting EnterohaemorrhagicEscherichia Coliin Food. FOOD REVIEWS INTERNATIONAL 2011. [DOI: 10.1080/87559129.2010.535232] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
32
|
Noguera P, Posthuma-Trumpie GA, van Tuil M, van der Wal FJ, de Boer A, Moers APHA, van Amerongen A. Carbon nanoparticles in lateral flow methods to detect genes encoding virulence factors of Shiga toxin-producing Escherichia coli. Anal Bioanal Chem 2011; 399:831-8. [PMID: 21046083 PMCID: PMC3015178 DOI: 10.1007/s00216-010-4334-z] [Citation(s) in RCA: 76] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2010] [Revised: 10/07/2010] [Accepted: 10/12/2010] [Indexed: 01/10/2023]
Abstract
The use of carbon nanoparticles is shown for the detection and identification of different Shiga toxin-producing Escherichia coli virulence factors (vt1, vt2, eae and ehxA) and a 16S control (specific for E. coli) based on the use of lateral flow strips (nucleic acid lateral flow immunoassay, NALFIA). Prior to the detection with NALFIA, a rapid amplification method with tagged primers was applied. In the evaluation of the optimised NALFIA strips, no cross-reactivity was found for any of the antibodies used. The limit of detection was higher than for quantitative PCR (q-PCR), in most cases between 10(4) and 10(5) colony forming units/mL or 0.1-0.9 ng/μL DNA. NALFIA strips were applied to 48 isolates from cattle faeces, and results were compared to those achieved by q-PCR. E. coli virulence factors identified by NALFIA were in very good agreement with those observed in q-PCR, showing in most cases sensitivity and specificity values of 1.0 and an almost perfect agreement between both methods (kappa coefficient larger than 0.9). The results demonstrate that the screening method developed is reliable, cost-effective and user-friendly, and that the procedure is fast as the total time required is <1 h, which includes amplification.
Collapse
Affiliation(s)
- P. Noguera
- Wageningen UR Food & Biobased Research, Biomolecular Sensing & Diagnostics, P.O. Box 17, 6700 AA Wageningen, the Netherlands
- Instituto de Reconocimiento Molecular y Desarrollo Tecnológico, Departamento de Química, Universidad Politécnica de Valencia, Camino de Vera, s/n, 46020 Valencia, Spain
| | - G. A. Posthuma-Trumpie
- Wageningen UR Food & Biobased Research, Biomolecular Sensing & Diagnostics, P.O. Box 17, 6700 AA Wageningen, the Netherlands
| | - M. van Tuil
- Wageningen UR Food & Biobased Research, Biomolecular Sensing & Diagnostics, P.O. Box 17, 6700 AA Wageningen, the Netherlands
| | - F. J. van der Wal
- Wageningen UR Central Veterinary Institute, Division Bacteriology and TSEs, P.O. Box 65, 8200 AB Lelystad, the Netherlands
| | - A. de Boer
- Wageningen UR Central Veterinary Institute, Division Bacteriology and TSEs, P.O. Box 65, 8200 AB Lelystad, the Netherlands
| | - A. P. H. A. Moers
- Wageningen UR Food & Biobased Research, Biomolecular Sensing & Diagnostics, P.O. Box 17, 6700 AA Wageningen, the Netherlands
| | - A. van Amerongen
- Wageningen UR Food & Biobased Research, Biomolecular Sensing & Diagnostics, P.O. Box 17, 6700 AA Wageningen, the Netherlands
| |
Collapse
|
33
|
Park J, Park S, Kim YK. Multiplex detection of pathogens using an immunochromatographic assay strip. BIOCHIP JOURNAL 2010. [DOI: 10.1007/s13206-010-4407-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
34
|
Van Dorst B, Mehta J, Bekaert K, Rouah-Martin E, De Coen W, Dubruel P, Blust R, Robbens J. Recent advances in recognition elements of food and environmental biosensors: a review. Biosens Bioelectron 2010; 26:1178-94. [PMID: 20729060 DOI: 10.1016/j.bios.2010.07.033] [Citation(s) in RCA: 158] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2010] [Revised: 07/08/2010] [Accepted: 07/11/2010] [Indexed: 12/12/2022]
Abstract
A sensitive monitoring of contaminants in food and environment, such as chemical compounds, toxins and pathogens, is essential to assess and avoid risks for both, human and environmental health. To accomplish this, there is a high need for sensitive, robust and cost-effective biosensors that make real time and in situ monitoring possible. Due to their high sensitivity, selectivity and versatility, affinity-based biosensors are interesting for monitoring contaminants in food and environment. Antibodies have long been the most popular affinity-based recognition elements, however recently a lot of research effort has been dedicated to the development of novel recognition elements with improved characteristics, like specificity, stability and cost-efficiency. This review discusses three of these innovative affinity-based recognition elements, namely, phages, nucleic acids and molecular imprinted polymers and gives an overview of biosensors for food and environmental applications where these novel affinity-based recognition elements are applied.
Collapse
Affiliation(s)
- Bieke Van Dorst
- University of Antwerp, Department of Biology, Laboratory of Ecophysiology, Biochemistry and Toxicology, Groenenborgerlaan 171, 2020 Antwerp, Belgium.
| | | | | | | | | | | | | | | |
Collapse
|
35
|
Yu YG, Wu H, Liu YY, Li SL, Yang XQ, Xiao XL. A multipathogen selective enrichment broth for simultaneous growth ofSalmonella entericaserovar Enteritidis,Staphylococcus aureus, andListeria monocytogenes. Can J Microbiol 2010; 56:585-97. [DOI: 10.1139/w10-040] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A selective enrichment broth (SSL) was formulated to allow concurrent growth of 3 prominent food-borne pathogens: Salmonella enterica serovar Enteritidis, Staphylococcus aureus , and Listeria monocytogenes . Nalidixic acid, lithium chloride, and potassium tellurite were added as the selective agents, while sodium pyruvate and mannitol were employed as the supplemented elements. In the individual growth trial, the target pathogens were capable of growing in SSL to as high as 7–8 log10colony-forming units (CFU)/mL after 24 h incubation at 37 °C when being inoculated at 50–100 CFU/mL. In the simultaneous growth trial, the 3 combined target pathogens showed similar growth rates. The results show that SSL could support the successful simultaneous enrichment of 3 pathogens; however, SSL inhibited the growth of nontarget bacteria. In the artificial contaminated raw beef and ready-to-eat chicken, a high recovery of these 3 target pathogens was obtained in SSL. Finally, Salmonella Enteritidis, Staphylococcus aureus, and L. monocytogenes were detected from 710 suspicious food samples by SSL with real-time PCR, and no false-positive or -negative results were reported. In summary, SSL has been shown to be a suitable broth for the simultaneous detection of the 3 prominent food-borne pathogens by multipathogen detection on a single-assay platform.
Collapse
Affiliation(s)
- Yi-Gang Yu
- Institution of Food Safety, College of Light Industry and Food Sciences, South China University of Technology, Guangzhou 510640, P.R. China
- Heilongjiang Entry–Exit Inspection and Quarantine Bureau, Harbin 150008, P.R. China
| | - Hui Wu
- Institution of Food Safety, College of Light Industry and Food Sciences, South China University of Technology, Guangzhou 510640, P.R. China
- Heilongjiang Entry–Exit Inspection and Quarantine Bureau, Harbin 150008, P.R. China
| | - Yuan-Yuan Liu
- Institution of Food Safety, College of Light Industry and Food Sciences, South China University of Technology, Guangzhou 510640, P.R. China
- Heilongjiang Entry–Exit Inspection and Quarantine Bureau, Harbin 150008, P.R. China
| | - Su-Long Li
- Institution of Food Safety, College of Light Industry and Food Sciences, South China University of Technology, Guangzhou 510640, P.R. China
- Heilongjiang Entry–Exit Inspection and Quarantine Bureau, Harbin 150008, P.R. China
| | - Xiao-Quan Yang
- Institution of Food Safety, College of Light Industry and Food Sciences, South China University of Technology, Guangzhou 510640, P.R. China
- Heilongjiang Entry–Exit Inspection and Quarantine Bureau, Harbin 150008, P.R. China
| | - Xing-Long Xiao
- Institution of Food Safety, College of Light Industry and Food Sciences, South China University of Technology, Guangzhou 510640, P.R. China
- Heilongjiang Entry–Exit Inspection and Quarantine Bureau, Harbin 150008, P.R. China
| |
Collapse
|
36
|
Brunt J, Webb MD, Peck MW. Rapid affinity immunochromatography column-based tests for sensitive detection of Clostridium botulinum neurotoxins and Escherichia coli O157. Appl Environ Microbiol 2010; 76:4143-50. [PMID: 20435757 PMCID: PMC2897428 DOI: 10.1128/aem.03059-09] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2009] [Accepted: 04/23/2010] [Indexed: 11/20/2022] Open
Abstract
Existing methods for detection of food-borne pathogens and their toxins are frequently time-consuming, require specialized equipment, and involve lengthy culture procedures and/or animal testing and are thus unsuitable for a rapid response to an emergency public health situation. A series of simple and rapid affinity immunochromatography column (AICC) assays were developed to detect Clostridium botulinum neurotoxin types A, B, E, and F and Escherichia coli O157 in food matrices. Specifically, for milk, grape juice with peach juice, and bottled water, the detection limit for the botulinum neurotoxin type A complex was 0.5 ng. Use of this method with a 10-ml sample would therefore result in a detection limit of 50 pg ml(-l). Thus, this assay is approximately 2 orders of magnitude more sensitive than a comparable lateral-flow assay. For botulinum neurotoxin complex types B, E, and F, the minimum detection limit was 5 ng to 50 ng. Sensitive detection of E. coli O157 was achieved, and the detection limit was 500 cells. The AICC test was also shown to be specific, rapid, and user friendly. This test takes only 15 to 30 min to complete without any specialized equipment and thus is suitable for use in the field. It has the potential to replace existing methods for presumptive detection of botulinum neurotoxin types A, B, E, and F and E. coli O157 in contaminated matrices without a requirement for preenrichment.
Collapse
Affiliation(s)
- Jason Brunt
- Institute of Food Research, Norwich Research Park, Colney, Norwich NR4 7UA, United Kingdom.
| | | | | |
Collapse
|
37
|
Park S, Kim YT, Kim YK. Optical enzyme-linked immunosorbent assay on a strip for detection of Salmonella typhimurium. BIOCHIP JOURNAL 2010. [DOI: 10.1007/s13206-010-4204-y] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
38
|
Rich RL, Myszka DG. Grading the commercial optical biosensor literature-Class of 2008: 'The Mighty Binders'. J Mol Recognit 2010; 23:1-64. [PMID: 20017116 DOI: 10.1002/jmr.1004] [Citation(s) in RCA: 109] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Optical biosensor technology continues to be the method of choice for label-free, real-time interaction analysis. But when it comes to improving the quality of the biosensor literature, education should be fundamental. Of the 1413 articles published in 2008, less than 30% would pass the requirements for high-school chemistry. To teach by example, we spotlight 10 papers that illustrate how to implement the technology properly. Then we grade every paper published in 2008 on a scale from A to F and outline what features make a biosensor article fabulous, middling or abysmal. To help improve the quality of published data, we focus on a few experimental, analysis and presentation mistakes that are alarmingly common. With the literature as a guide, we want to ensure that no user is left behind.
Collapse
Affiliation(s)
- Rebecca L Rich
- Center for Biomolecular Interaction Analysis, University of Utah, Salt Lake City, UT 84132, USA
| | | |
Collapse
|
39
|
An overview of foodborne pathogen detection: In the perspective of biosensors. Biotechnol Adv 2010; 28:232-54. [DOI: 10.1016/j.biotechadv.2009.12.004] [Citation(s) in RCA: 805] [Impact Index Per Article: 57.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2008] [Revised: 12/03/2009] [Accepted: 12/04/2009] [Indexed: 12/12/2022]
|
40
|
Xiao XL, Li YJ, Qin YY, Yu YG, Wu H. A multipathogen selective enrichment broth for simultaneous growth of Salmonella spp., Vibrio parahaemolyticus, and Vibrio cholerae. J GEN APPL MICROBIOL 2010; 56:465-74. [DOI: 10.2323/jgam.56.465] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
41
|
La Belle J, Shah M, Reed J, Nandakumar V, Alford T, Wilson J, Nickerson C, Joshi L. Label-Free and Ultra-Low Level Detection ofSalmonella entericaSerovar Typhimurium Using Electrochemical Impedance Spectroscopy. ELECTROANAL 2009. [DOI: 10.1002/elan.200904666] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
42
|
Abu-Rabeah K, Ashkenazi A, Atias D, Amir L, Marks R. Highly sensitive amperometric immunosensor for the detection of Escherichia coli. Biosens Bioelectron 2009; 24:3461-6. [DOI: 10.1016/j.bios.2009.04.042] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2009] [Revised: 04/25/2009] [Accepted: 04/27/2009] [Indexed: 11/17/2022]
|