1
|
Zeng J, Wu W, Chen X, Wang S, Wu H, El-Kady AA, Poapolathep A, Cifuentes A, Ibañez E, Li P, Zhang Z. A smartphone-assisted photoelectrochemical POCT method via Z-scheme CuCo 2S 4/Fe 3O 4 for simultaneously detecting co-contamination with microplastics in food and the environment. Food Chem 2024; 452:139430. [PMID: 38713984 DOI: 10.1016/j.foodchem.2024.139430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 04/18/2024] [Accepted: 04/19/2024] [Indexed: 05/09/2024]
Abstract
As emerging contaminants, microplastics threaten food and environmental safety. Dibutyl phthalate (DBP, released from microplastics) and benzo[a]pyrene (BaP, adsorbed on microplastics) coexisted in food and the environment, harming human health, requesting a sensitive and simultaneous testing method to monitor. To address current sensitivity, simultaneousness, and on-site portability challenges during dual targets in complex matrixes, CuCo2S4/Fe3O4 nanoflower was designed to develop a smartphone-assisted photoelectrochemical point-of-care test (PEC POCT). The carrier transfer mechanism in CuCo2S4/Fe3O4 was proven via density functional theory calculation. Under optimal conditions, the PEC POCT showed low detection limits of 0.126, and 0.132 pg/mL, wide linearity of 0.001-500, and 0.0005-50 ng/mL for DBP and BaP, respectively. The smartphone-assisted PEC POCT demonstrated satisfied recoveries (80.00%-119.63%) in real samples. Coherent results were recorded by comparing the PEC POCT to GC-MS (DBP) and HPLC (BaP). This novel method provides a practical platform for simultaneous POCT for food safety and environment monitoring.
Collapse
Affiliation(s)
- Jing Zeng
- College of Chemistry & Chemical Engineering, Hubei University, Wuhan 430062, PR China; School of Bioengineering and Health, State Key Laboratory of New Textile Materials and Advanced Processing Technologies, Wuhan Textile University, Wuhan 430200, PR China
| | - Wenqin Wu
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Hubei Hongshan Laboratory, Key Laboratory of Biology and Genetic Improvement of Oil Crops, Key Laboratory of Detection for Mycotoxins, National Reference Lab for Biotoxin Test, Wuhan 430062, PR China
| | - Xiao Chen
- College of Chemistry & Chemical Engineering, Hubei University, Wuhan 430062, PR China
| | - Shenling Wang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Hubei Hongshan Laboratory, Key Laboratory of Biology and Genetic Improvement of Oil Crops, Key Laboratory of Detection for Mycotoxins, National Reference Lab for Biotoxin Test, Wuhan 430062, PR China
| | - Huimin Wu
- College of Chemistry & Chemical Engineering, Hubei University, Wuhan 430062, PR China.
| | - Ahmed A El-Kady
- Food Toxicology and Contaminants Department, National Research Centre, Giza, Egypt
| | - Amnart Poapolathep
- Department of Pharmacology, Faculty of Veterinary Medicine, Kasetsart University, Bangkok 10900, Thailand
| | | | - Elena Ibañez
- National Research Council Spain, CSIC, CIAL, Lab Food, Madrid, Spain
| | - Peiwu Li
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Hubei Hongshan Laboratory, Key Laboratory of Biology and Genetic Improvement of Oil Crops, Key Laboratory of Detection for Mycotoxins, National Reference Lab for Biotoxin Test, Wuhan 430062, PR China
| | - Zhaowei Zhang
- School of Bioengineering and Health, State Key Laboratory of New Textile Materials and Advanced Processing Technologies, Wuhan Textile University, Wuhan 430200, PR China; Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Hubei Hongshan Laboratory, Key Laboratory of Biology and Genetic Improvement of Oil Crops, Key Laboratory of Detection for Mycotoxins, National Reference Lab for Biotoxin Test, Wuhan 430062, PR China.
| |
Collapse
|
2
|
Srinivasan P, Rajaji U, Sethuraman MG, Karuppiah C, Yusuf K, Liu TY. Rapid detection of tertiary butylated hydroquinone in food samples using Mn-MOF@f-CNF composite-modified screen-printed electrode. Mikrochim Acta 2024; 191:576. [PMID: 39240389 DOI: 10.1007/s00604-024-06642-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2024] [Accepted: 08/19/2024] [Indexed: 09/07/2024]
Abstract
Hydroquinone-based organic molecules are often used as unavoidable preservatives in the food industry. Among these additives, tertiary butylated hydroquinone (TBHQ) is widely employed as a preservative in various processed foods. However, the potential health risks associated with the excessive presence of TBHQ in food products have raised significant concerns. To address this pressing issuea novel binder-free composite composed of a manganese metal-organic framework and functionalized carbon nanofibers (Mn-MOF/f-CNF) has been developed as an electrode modifier for the ultrasensitive detection of TBHQ in food samples. The Mn-MOF/f-CNF composite was achieved using the ultrasonication method, revealing a lamellar sheet-like structure of the Mn-MOF and the curly thread-like fibrous structure of f-CNF. The developed Mn-MOF/f-CNF/SPE sensor system resulted in well-defined redox signals for TBHQ detection in a neutral pH solution. Compared to the unmodified SPE system, the modified system showed approximately a 300 mV reduction in overpotential and a twofold increase in peak current signal for TBHQ detection. The Mn-MOF/f-CNF/SPE sensor system showed a linear concentration window of 0.01 to 800 μM with a sensitivity of 6.28 µA µM-1 cm-2 and the obtained detection limit was 1.36 nM. Additionally, the proposed sensor displayed excellent reproducibility and repeatable results with an RSD of less than 5%. The real-time applicability of the Mn-MOF/f-CNF/SPE sensor system was demonstrated using real samples such as potato chips and instant noodles, showing excellent results with a recovery range of 95.1-98.5%.
Collapse
Affiliation(s)
- Praveenkannan Srinivasan
- Department of Chemistry, The Gandhigram Rural Institute-Deemed to Be University, Gandhigram, 624 302, Dindigul, Tamil Nadu, India
| | - Umamaheswari Rajaji
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei City, 243303, Taiwan
- Centre for Applied Research, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences (SIMATS), Chennai, Tamil Nadu, 602105, India
- Research Center for Intelligence Medical Devices, Ming Chi University of Technology, 243303, New Taipei City, Taiwan
| | - Mathur Gopalakrishnan Sethuraman
- Department of Chemistry, The Gandhigram Rural Institute-Deemed to Be University, Gandhigram, 624 302, Dindigul, Tamil Nadu, India.
| | - Chelladurai Karuppiah
- Department of Chemistry and Green-Nano Materials Research Center, Kyungpook National University, Daegu, 41566, Republic of Korea
| | - Kareem Yusuf
- Department of Chemistry, College of Science, King Saud University, 11451, Riyadh, Saudi Arabia
| | - Ting-Yu Liu
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei City, 243303, Taiwan.
- Center for Environmental Sustainability and Human Health, R&D Center of Biochemical Engineering Technology, Ming Chi University of Technology, New Taipei City, 24301, Taiwan.
- Department of Chemical Engineering and Materials Science, Yuan Ze University, Taoyuan, 32003, Taiwan.
- College of Engineering & Center for Sustainability and Energy Technologies, Chang Gung University, Taoyuan, 33302, Taiwan.
| |
Collapse
|
3
|
Wang J, Sun G, Li F, Zhu Z, Sun L, Lv P, Yue H. Development of ZnCdSe/ZnS quantum dot-based fluorescence immunochromatographic assay for the rapid visual and quantitative detection 25⁃hydroxyvitamins D in human serum. Front Bioeng Biotechnol 2023; 11:1326254. [PMID: 38188486 PMCID: PMC10766695 DOI: 10.3389/fbioe.2023.1326254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Accepted: 12/05/2023] [Indexed: 01/09/2024] Open
Abstract
Vitamin D deficiency is associated with various diseases such as obesity, digestive problems, osteoporosis, depression, and infections, and has therefore emerged as a topic of great interest in public healthcare. The quantitative assessment of 25-hydroxyvitamin D (25-OH VD) in human serum may accurately reflect the nutritional status of vitamin D in the human body, which is significant for the prevention and treatment of vitamin D-deficient patients. In this study, we developed an assay for quantitative detection of 25-OH VD based on the 25-OH VD monoclonal antibody (mAb), and identified the optimal process parameters. The following process settings were found to be suitable for the test strips: pH of 7.6, 1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) ratio of 1:2000, and the anti-25-OH VD mAb ratio was 1:8. The equilibration time of the immune dynamic assay was 15 min. Under optimal conditions, the quantum dot nanoparticle-based fluorescent immunochromatographic assay (QDs-FICA) exhibited dynamic linear detection of 25-OH VD in PBS, from 5 ng/mL to 100 ng/mL, and the strip quantitative curve could be represented by the following regression equation: y = -0.02088 logx)+1.444 (R2 = 0.9050). The IC50 of the QDs-FICA was 39.6 ± 1.33 ng/mL. The specificity of the QDs-FICA was evaluated by running several structurally related analogues, including 25-OH VD2, 25-OH VD3, 1,25-OH2VD3, 1,25-OH2VD2, VD2, and VD3. The coefficients of variation were all below 10%. The shelf life of the test strips in this study was about 160 days at room temperature. Briefly, this study is the first to perform QDs-FICA for the rapid visual and quantitative detection of 25-OH VD, with great potential significance for clinical diagnosis of vitamin D-associated diseases.
Collapse
Affiliation(s)
- Jianfa Wang
- Department of Orthopedics, Zhengzhou Central Hospital Affiliated Zhengzhou University, Zhengzhou, Henan, China
| | - Guoshao Sun
- Department of Orthopedics, Zhengzhou Central Hospital Affiliated Zhengzhou University, Zhengzhou, Henan, China
| | - Fang Li
- Department of Orthopedics, Zhengzhou Central Hospital Affiliated Zhengzhou University, Zhengzhou, Henan, China
| | - Zhi Zhu
- Department of Orthopedics, Zhengzhou Central Hospital Affiliated Zhengzhou University, Zhengzhou, Henan, China
| | - Lei Sun
- Center of Stem Cell and Regenerative Medicine, Zhengzhou Central Hospital Affiliated Zhengzhou University, Zhengzhou, Henan, China
| | - Pengju Lv
- Center of Stem Cell and Regenerative Medicine, Zhengzhou Central Hospital Affiliated Zhengzhou University, Zhengzhou, Henan, China
| | - Han Yue
- Center of Stem Cell and Regenerative Medicine, Zhengzhou Central Hospital Affiliated Zhengzhou University, Zhengzhou, Henan, China
| |
Collapse
|
4
|
Feng J, Li C, Liu WNY, Min X, Lin X. Co-MOF@MWCNTs/GCE for the sensitive detection of TBHQ in food samples. Dalton Trans 2023; 52:16754-16766. [PMID: 37902558 DOI: 10.1039/d3dt03158f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2023]
Abstract
tert-Butylhydroquinone (TBHQ) is a novel synthetic antioxidant with a higher safety profile and antioxidant effect that is more excellent than other synthetic antioxidants and is internationally recognized as one of the best food antioxidants. However, its excessive use in food can have unfavorable effects on the human body. Thus, it is critical to establish a rapid method for the detection of TBHQ in food samples. In this study, a cobalt-based metal-organic framework (Co-MOF) was fabricated by a one-pot hydrothermal method and embedded in multi-walled carbon nanotubes (MWCNTs) to construct an economical and sensitive electrochemical sensor for TBHQ. The results showed that this sensor possessed a wide linear range (0.004-20 μM and 20-300 μM), a low limit of detection (LOD = 2.5 nM, S/N = 3) as well as an ultra-high sensitivity (43.19 μA μM-1 cm-2). Moreover, the sensor also has superior selectivity, repeatability, reproducibility and anti-interference ability and can be successfully applied for the detection of TBHQ in samples of instant noodles and potato chips.
Collapse
Affiliation(s)
- Junhui Feng
- School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, China.
| | - Chenxin Li
- School of Infrastructure Engineering, Nanchang University, Nanchang 330031, China
| | - Wan-Nai-Yi Liu
- School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, China.
| | - Xiaoqin Min
- School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, China.
| | - Xiaoyun Lin
- School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, China.
| |
Collapse
|
5
|
Zhang R, Zheng D, Chen J, Zhang C, Wang C. Design of NiS@Ni3S2/CdS heterostructure with intimate contact interface for sensitive photoelectrochemical detection of lincomycin. Food Chem 2023; 418:136028. [PMID: 37015148 DOI: 10.1016/j.foodchem.2023.136028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 03/19/2023] [Accepted: 03/21/2023] [Indexed: 04/05/2023]
Abstract
Owing to their internal electric field effect and abundant photo-induced carriers, photoactive heterostructured materials are considered a feasible approach to improve the sensitivity of a photoelectrochemical (PEC) sensor. Herein, a novel NiS@Ni3S2/CdS heterostructure composite is derived from Ni-loaded zeolitic imidazolate framework (Ni-ZIF). The PEC experiments showed the NiS@Ni3S2/CdS composite exhibits superior photocurrent response than NiS@Ni3S2 and CdS. This is attributed to the fact that the type II heterojunction of NiS@Ni3S2/CdS with a tightly connected interface reduces the transport distance of carriers and facilitates electron-hole separation. Next, using the NiS@Ni3S2/CdS modified electrode, an aptamer/glutaraldehyde/chitosan/NiS@Ni3S2/CdS/ITO PEC biosensor is developed, which exhibits excellent sensitivity for lincomycin (Lin) detection with a wide linear range (0.0001 ∼ 1.25 nM) and a low detection limit of 0.067 pM. The prepared sensor is further employed to monitor Lin in the actual milk. The results confirm that the prepared sensing electrode displays good selectivity, repeatability and stability.
Collapse
|
6
|
MXene-mediated in situ formation of Schottky junction for selective and sensitive detection of antioxidant tertiary butylhydroquinone in edible oil. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
7
|
Lima FMR, de Menezes AS, Maciel AP, Sinfrônio FSM, Kubota LT, Damos FS, Luz RCS. Zero-Biased Photoelectrochemical Detection of Cardiac Biomarker Myoglobin Based on CdSeS/ZnS Quantum Dots and Barium Titanate Perovskite. Molecules 2022; 27:molecules27154778. [PMID: 35897951 PMCID: PMC9330231 DOI: 10.3390/molecules27154778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Revised: 07/10/2022] [Accepted: 07/21/2022] [Indexed: 02/05/2023] Open
Abstract
Cardiovascular diseases are considered one of the leading causes of premature mortality of patients worldwide. Therefore, rapid diagnosis of these diseases is crucial to ensure the patient's survival. During a heart attack or severe muscle damage, myoglobin is rapidly released in the body to constitute itself as a precise biomarker of acute myocardial infarction. Thus, we described the photoelectrochemical immunosensor development to detect myoglobin. It was based on fluorine-doped tin oxide modified with CdSeS/ZnSe quantum dots and barium titanate (BTO), designated as CdSeS/ZnSQDS/BTO. It was characterized by scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDX), transmission electron microscopy (TEM), X-ray diffraction (XRD), electrochemical impedance spectroscopy (EIS), and amperometry. The anodic photocurrent at the potential of 0 V (vs. Ag/AgCl) and pH 7.4 was found linearly related to the myoglobin (Mb) concentration from 0.01 to 1000 ng mL-1. Furthermore, the immunosensor showed an average recovery rate of 95.7-110.7% for the determination of myoglobin.
Collapse
Affiliation(s)
- Fernanda M. R. Lima
- Department of Chemistry, Federal University of Maranhão, São Luís 65080-805, Brazil; (F.M.R.L.); (A.P.M.)
| | - Alan S. de Menezes
- Department of Physics, Federal University of Maranhão, São Luís 65080-805, Brazil;
| | - Adeilton P. Maciel
- Department of Chemistry, Federal University of Maranhão, São Luís 65080-805, Brazil; (F.M.R.L.); (A.P.M.)
| | | | - Lauro T. Kubota
- Institute of Chemistry, State University of Campinas, Campinas 13083-970, Brazil;
| | - Flávio S. Damos
- Department of Chemistry, Federal University of Maranhão, São Luís 65080-805, Brazil; (F.M.R.L.); (A.P.M.)
- Correspondence: (F.S.D.); (R.C.S.L.)
| | - Rita C. S. Luz
- Department of Chemistry, Federal University of Maranhão, São Luís 65080-805, Brazil; (F.M.R.L.); (A.P.M.)
- Correspondence: (F.S.D.); (R.C.S.L.)
| |
Collapse
|
8
|
Khezerlou A, Akhlaghi AP, Alizadeh AM, Dehghan P, Maleki P. Alarming impact of the excessive use of tert-butylhydroquinone in food products: A narrative review. Toxicol Rep 2022; 9:1066-1075. [PMID: 36561954 PMCID: PMC9764193 DOI: 10.1016/j.toxrep.2022.04.027] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 04/27/2022] [Accepted: 04/28/2022] [Indexed: 12/25/2022] Open
Abstract
Tert-butyl hydroquinone (TBHQ) is a food additive commonly used as a more effective protectant in the food, cosmetic and pharmaceutical industries. However, the long-term exposure to TBHQ at higher doses (0.7 mg/kg) results in substantial danger to public health and brings a series of side effects, including cytotoxic, genotoxic, carcinogenic, and mutagenic effects. As a result, the global burden of chronic diseases has fascinated consumers and governments regarding the safety assessment of food additives. Regarding contradictory reports of various research about the application of food additives, the accurate monitoring of food additives is urgent. Notwithstanding, there are reports of the therapeutic effects of TBHQ under pathologic conditions through activation of nuclear factor erythroid 2-related factor 2. Thus, further investigations are required to investigate the impact of TBHQ on public health and evaluate its mechanism of action on various organs and cells. Therefore, this review aimed to investigate TBHQ safety through an overview of its impacts on different tissues, cells, and biological macromolecules as well as its therapeutic effects under pathologic conditions.
Collapse
Affiliation(s)
- Arezou Khezerlou
- Student Research Committee, Department of Food Science and Technology, Faculty of Nutrition and Food Science, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Amir pouya Akhlaghi
- Student Research Committee, Department of Food Science and Technology, Faculty of Nutrition and Food Science, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Adel Mirza Alizadeh
- Department of Food Safety and Hygiene, School of Public Health, Zanjan University of Medical Sciences, Zanjan, Iran
| | - Parvin Dehghan
- Cardiovascular Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Parham Maleki
- Student Research Committee, Department of Food Science and Technology, Faculty of Nutrition and Food Science, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
9
|
Karthikeyan R, Nelson DJ, Ajith A, John SA. Hetero atoms doped carbon dots modified electrodes for the sensitive and selective determination of phenolic anti-oxidant in coconut oil. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.113297] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
10
|
Yue X, Luo X, Zhou Z, Bai Y. Selective electrochemical determination of tertiary butylhydroquinone in edible oils based on an in-situ assembly molecularly imprinted polymer sensor. Food Chem 2019; 289:84-94. [DOI: 10.1016/j.foodchem.2019.03.044] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2018] [Revised: 03/05/2019] [Accepted: 03/10/2019] [Indexed: 11/15/2022]
|
11
|
dos Santos GKC, da Silva FGS, Ferreira AR, de Cássia Silva Luz R, Damos FS. Development of a self-powered photoelectrochemical system (SPPS) for the determination of propyl gallate. Microchem J 2019. [DOI: 10.1016/j.microc.2019.05.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
12
|
Photoelectrochemical platform for sensing propyl gallate in edible oil samples based on CdTe quantum dots and poly(D-glucosamine). J Solid State Electrochem 2019. [DOI: 10.1007/s10008-018-04177-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
13
|
|
14
|
Sousa KAP, Lima FMR, Monteiro TO, Silva SM, Goulart MOF, Damos FS, Luz RDCS. Amperometric Photosensor Based on Acridine Orange/TiO2 for Chlorogenic Acid Determination in Food Samples. FOOD ANAL METHOD 2018. [DOI: 10.1007/s12161-018-1261-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
15
|
Self-powered Photoelectrochemical Sensor for Gallic Acid Exploiting a CdSe/ZnS Core-shell Quantum Dot Sensitized TiO2
as Photoanode. ELECTROANAL 2018. [DOI: 10.1002/elan.201800133] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|