1
|
Panapong K, Wechakorn K, Binhayeeniyi N, Teepoo S. Dual-color immunochromatographic test strip for simultaneous sensitive detection of malachite green and leucomalachite green residues in fish and shrimp meat samples. Food Chem 2024; 463:141427. [PMID: 39348768 DOI: 10.1016/j.foodchem.2024.141427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Revised: 09/23/2024] [Accepted: 09/23/2024] [Indexed: 10/02/2024]
Abstract
A sensitive dual immunochromatographic test strip (dual-ICTS) was developed to detect malachite green (MG) and its metabolite, leucomalachite green (LMG), using two types of gold nanoparticles: round-shaped (red) and star-shaped (blue). The detection limits were determined to be 0.221 μg L-1 for MG and 0.214 μg L-1 for LMG, respectively. The dual-ICTS provided a cut-off value of 1.8 μg L-1 for MG and LMG detection. The dual-ICTS successfully detected MG and LMG in food samples, with recovery rates ranging from 86 % to 116 %. The dual-ICTS was evaluated by correlation analysis between the proposed assay and the well-established enzyme-linked immunosorbent assay in the MG and LMG detection. This is the first report on the development of the ICTS that can detect both MG and LMG at the same time within only 5 min, making it a sensitive and rapid tool for on-site detection.
Collapse
Affiliation(s)
- Khaunnapa Panapong
- Department of Chemistry, Faculty of Science and Technology, Rajamangala University of Technology Thanyaburi, Thanyaburi, Pathum Thani 12110, Thailand
| | - Kanokorn Wechakorn
- Department of Chemistry, Faculty of Science and Technology, Rajamangala University of Technology Thanyaburi, Thanyaburi, Pathum Thani 12110, Thailand
| | - Nawal Binhayeeniyi
- Faculty of Science and Technology, Princess of Naradhiwas University, Narathiwat 96000, Thailand
| | - Siriwan Teepoo
- Department of Chemistry, Faculty of Science and Technology, Rajamangala University of Technology Thanyaburi, Thanyaburi, Pathum Thani 12110, Thailand.
| |
Collapse
|
2
|
Ye M, Lin X, Li J, Chen X, Ying D, Wu S, Wang Z, Duan N. Dual-mode aptasensor based on P-CeO 2NR@Mxene and exonuclease I-assisted target recycling for malachite green detection. Food Chem 2024; 451:139399. [PMID: 38663240 DOI: 10.1016/j.foodchem.2024.139399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 04/11/2024] [Accepted: 04/15/2024] [Indexed: 05/26/2024]
Abstract
Malachite green (MG) has been illicitly employed in aquaculture as a parasiticide, however, its teratogenic and carcinogenic effects pose a significant human health threat. Herein, a dual-mode colorimetric and electrochemical aptasensor was fabricated for MG detection, capitalizing on the robust catalytic and peroxidase-like activity of P-CeO2NR@Mxene and good capture efficiency of a tetrahedral DNA nanostructure (TDN) designed with multiple aptamers (m-TDN). P-CeO2NR@Mxene-modified complementary DNA (cDNA) served as both colorimetric and electrochemical probe. m-TDN was attached to AuE to capture MG and P-CeO2NR@Mxene/cDNA. The superior aptamer and MG binding to cDNA regulated signals and enabled precise MG quantification. The further introduced Exo I enabled aptamer hydrolysis, releasing MG for further binding rounds, allowing target recycling amplification. Under the optimal conditions, the aptasensor reached an impressively low detection limit 95.4 pM in colorimetric mode and 83.6 fM in electrochemical mode. We believe this dual-mode approach holds promise for veterinary drug residue detection.
Collapse
Affiliation(s)
- Mingyue Ye
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Xianfeng Lin
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Jin Li
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Xiaowan Chen
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Dichen Ying
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Shijia Wu
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China
| | - Zhouping Wang
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China
| | - Nuo Duan
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China.
| |
Collapse
|
3
|
Zhang X, Hao N, Liu S, Wei K, Ma C, Pan J, Feng S. Direct and specific detection of methyl-paraoxon using a highly sensitive fluorescence strategy combined with phosphatase-like nanozyme and molecularly imprinted polymer. Talanta 2024; 277:126434. [PMID: 38879946 DOI: 10.1016/j.talanta.2024.126434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 06/10/2024] [Accepted: 06/13/2024] [Indexed: 06/18/2024]
Abstract
Methyl paraoxon (MP) is a highly toxic, efficient and broad-spectrum organophosphorus pesticide, which poses significant risks to ecological environment and human health. Many detection methods for MP are based on the enzyme catalytic or inhibition effect. But natural biological enzymes are relatively expensive and easy to be inactivated with a short service life. As a unique tool of nanotechnology with enzyme-like characteristics, nanozyme has attracted increasing concern. However, a large proportion of nanozymes lack the intrinsic specificity, becoming a main barrier of constraining their use in biochemical analysis. Here, we use a one-pot reverse microemulsion polymerization combine the gold nanoclusters (AuNCs) with molecularly imprinted polymers (MIPs), polydopamine (PDA) and hollow CeO2 nanospheres to synthesize the bright red-orange fluorescence probe (CeO2@PDA@AuNCs-MIPs) with high phosphatase-like activity for selective detection of MP. The hollow structure possesses a specific surface area and porous matrix, which not only increases the exposure of active sites but also enhances the efficiency of mass and electron transport. Consequently, this structure significantly enhances the catalytic activity by reducing transport distances. The introduced MIPs provide the specific recognition sites for MP. And Ce (III) can excite aggregation induced emission of AuNCs and enhance the fluorescent signal. The absolute fluorescence quantum yield (FLQY) of CeO2@PDA@AuNCs-MIPs (1.41 %) was 12.8-fold higher than that of the GSH-AuNCs (0.11 %). With the presence of MP, Ce (IV)/Ce (III) species serve as the active sites to polarize and hydrolyze phosphate bonds to generate p-nitrophenol (p-NP), which can quench the fluorescent signal through the inner-filter effect. The as-prepared CeO2@PDA@AuNCs-MIPs nanozyme-based fluorescence method for MP detection displayed superior analytical performances with wide linearities range of 0.45-125 nM and the detection limit of 0.15 nM. Furthermore, the designed method offers satisfactory practical application ability. The developed method is simple and effective for the in-field detection.
Collapse
Affiliation(s)
- Xuan Zhang
- School of Environmental Science and Engineering, Changzhou University, Jiangsu 213164, China
| | - Nan Hao
- School of Chemistry and Chemical Engineering, Nanjing University of Information Science &Technology 211800, China.
| | - Shucheng Liu
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Kai Wei
- School of Environmental Science and Engineering, Changzhou University, Jiangsu 213164, China
| | - Changchang Ma
- School of Environmental Science and Engineering, Changzhou University, Jiangsu 213164, China
| | - Jianming Pan
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang 212013, China.
| | - Sheng Feng
- School of Environmental Science and Engineering, Changzhou University, Jiangsu 213164, China.
| |
Collapse
|
4
|
Li HZ, Qian HL, Xu ST, Yang C, Yan XP. Tuning the planarity of molecularly imprinted covalent organic frameworks for selective extraction of ochratoxin A in alcohol samples. Food Chem 2024; 451:139427. [PMID: 38692237 DOI: 10.1016/j.foodchem.2024.139427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 04/16/2024] [Accepted: 04/18/2024] [Indexed: 05/03/2024]
Abstract
Here, we report a monomer planarity modulation strategy for room-temperature constructing molecularly imprinted-covalent organic frameworks (MI-COFs) for selective extraction of ochratoxin A (OTA). 2,4,6-triformylphloroglucinol (Tp) was used as basic building block, while three amino monomers with different planarity were employed as modulators to explore the effect of planarity on the selectivity of MI-COFs. The MI-TpTapa constructed from Tp and the lowest planarity of monomer Tapa gave the highest selectivity for OTA, and was further used as the adsorbent for dispersed-solid phase extraction (DSPE) of OTA in alcohol samples. Coupling MI-TpTapa based DSPE with high-performance liquid chromatography allowed the matrix-effect free determination of OTA in alcohol samples with the limit of detection of 0.023 μg kg-1 and the recoveries of 91.4-97.6%. The relative standard deviation (RSD, n = 6) of intra and inter day was <3.2%. This work provides a new way to construct MI-COFs for selective extraction of hazardous targets.
Collapse
Affiliation(s)
- Hao-Ze Li
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China; Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Hai-Long Qian
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China; Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Shu-Ting Xu
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China; Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Cheng Yang
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China; Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Xiu-Ping Yan
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China; Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China; Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, Jiangnan University, Wuxi 214122, China.
| |
Collapse
|
5
|
Jiang L, Li C, Hou X. Smartphone-based dual inverse signal MOFs fluorescence sensing for intelligent on-site visual detection of malachite green. Talanta 2024; 274:126039. [PMID: 38604043 DOI: 10.1016/j.talanta.2024.126039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 03/20/2024] [Accepted: 04/02/2024] [Indexed: 04/13/2024]
Abstract
The development of intelligent, sensitive, and visual methods for the rapid detection of veterinary drug residues is essential to ensure food quality and safety. Here, a smartphone-based dual inverse signal MOFs fluorescence sensing system was proposed for intelligent in-site visual detection of malachite green (MG). A UiO-66-NH2@RhB-dual-emission fluorescent probe was successfully synthesized in one step using a simple one-pot method. The inner filter effect (IFE) quenches the red fluorescence, while hydrogen bonding interaction enhances the blue fluorescence, enabling highly sensitive, accurate, and visual detection of MG dual inverse signals through fluorescence analysis. The probe showed great linearity over a wide range of 0.1-100 μmol/L, with a limit of detection (LOD) of 20 nmol/L. By integrating smartphone photography and RGB (red, green, and blue) analysis, accurate quantitative analysis of MG in water and actual fish samples can be achieved within 5 min. This developed platform holds great promise for the on-site detection of MG in practical applications, with the advantages of simplicity, cost-effectiveness, and rapidity. Consequently, it may open up a new pathway for on-site evaluation of food safety and environmental health.
Collapse
Affiliation(s)
- Lianshuang Jiang
- Analytical & Testing Center, Sichuan University, Chengdu, Sichuan, 610064, China
| | - Chenghui Li
- Analytical & Testing Center, Sichuan University, Chengdu, Sichuan, 610064, China.
| | - Xiandeng Hou
- Analytical & Testing Center, Sichuan University, Chengdu, Sichuan, 610064, China; Key Laboratory of Green Chemistry & Technology, Ministry of Education, and College of Chemistry, Sichuan University, Chengdu, Sichuan, 610064, China.
| |
Collapse
|
6
|
He J, Chen Y, Liu H, Sun B. A Ratiometric Molecularly Imprinted Sensor for Visual Detection and Removal of α-Dicarbonyl Compounds Based on Biomass Carbon Dot-Embedded Fluorescent Covalent Organic Frameworks. ACS Sens 2024; 9:3338-3345. [PMID: 38814087 DOI: 10.1021/acssensors.4c00665] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2024]
Abstract
α-Dicarbonyl compounds (α-DCs) are important intermediate products during the thermal processing of foods and are closely related to the development of chronic diseases in the human body. However, there remains a significant gap in the availability of rapid detection methods for α-DCs. So, the ratiometric molecularly imprinted polymers (RCDs@GCOFs@MIPs) based on red-emitting biomass carbon dots (RCDs) and green-emitting fluorescent covalent organic frameworks (GCOFs) were constructed for the detection and removal of α-DCs in food processing. The ratiometric fluorescent sensors exhibited satisfactory detection and had good spiking recoveries in milk samples. And the excellent inhibition of pyrraline (PRL) by ratiometric fluorescent sensors was verified by simulating the milk pasteurization process. In addition, rapid onsite detection of α-DCs was achieved by recognizing the RGB value of the ratiometric fluorescence sensors via the smartphone. The ratiometric fluorescence sensors presented a new strategy for detecting and removing hazardous substances in food processing.
Collapse
Affiliation(s)
- Jingbo He
- Key Laboratory of Geriatric Nutrition and Health (Beijing Technology and Business University), Ministry of Education, 11 Fucheng Road, Beijing 100048, China
| | - Yunhai Chen
- Key Laboratory of Geriatric Nutrition and Health (Beijing Technology and Business University), Ministry of Education, 11 Fucheng Road, Beijing 100048, China
| | - Huilin Liu
- Key Laboratory of Geriatric Nutrition and Health (Beijing Technology and Business University), Ministry of Education, 11 Fucheng Road, Beijing 100048, China
| | - Baoguo Sun
- Key Laboratory of Geriatric Nutrition and Health (Beijing Technology and Business University), Ministry of Education, 11 Fucheng Road, Beijing 100048, China
| |
Collapse
|
7
|
Zhang Y, Wang C, Wei G, Wang X, Liu W, Yang G, Zhang P, Li Q, Geng X, Chen L, Song Z. Facile fluorescence detection of malachite green in fish using molecularly imprinted polymers doped CdTe quantum dots based system. Food Chem 2024; 442:138458. [PMID: 38278103 DOI: 10.1016/j.foodchem.2024.138458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 01/14/2024] [Accepted: 01/14/2024] [Indexed: 01/28/2024]
Abstract
Malachite green (MG) possesses high toxicity, therefore, the detection of MG in fish tissues is of vital importance. A novel core-shell MIPs doped CdTe quantum dots coated silica nanoparticles (CdTe-MIP/SiO2 NPs) were synthesized via a simple one-pot strategy. The materials were characterized carefully. The resulting CdTe-MIP/SiO2 NPs were coated on the thin layer chromatography plate, and coupled with miniaturized fluorimeter for fluorescence detection of MG in fish samples. The resulting CdTe-MIP/SiO2 NPs based system possessed good linearity (0.01 ∼ 20 μmol/L), high recoveries (98.36 %∼101.45 %) and low detection limit (3.7 nmol/L) for MG. Furthermore, CdTe-MIP/SiO2 NPs based system were employed to measure fish samples spiked with MG, meanwhile, HPLC was utilized to evaluate the accuracy and reliability. And the paired t-test was conducted to evaluate differences between fluorescence method and HPLC, P > 0.05 means no significant difference was observed, the results demonstrated that both fluorescence method and HPLC are suitable for MG analysis.
Collapse
Affiliation(s)
- Yimeng Zhang
- School of Pharmacy, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Yantai University, Yantai 264005, PR China
| | - Chuanliang Wang
- Department of Instrumentation & Analytical Chemistry, CAS Key Laboratory of Separation Sciences for Analytical Chemistry, Key Laboratory of Deep-sea Composition Detection Technology of Liaoning Province, Dalian Institute of Chemical Physics, CAS, 457 Zhongshan Road, Dalian 116023, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Guo Wei
- School of Pharmacy, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Yantai University, Yantai 264005, PR China
| | - Xuesong Wang
- School of Pharmacy, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Yantai University, Yantai 264005, PR China
| | - Wanhui Liu
- School of Pharmacy, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Yantai University, Yantai 264005, PR China
| | - Gangqiang Yang
- School of Pharmacy, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Yantai University, Yantai 264005, PR China
| | - Peng Zhang
- School of Pharmacy, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Yantai University, Yantai 264005, PR China
| | - Qinglian Li
- Department of Instrumentation & Analytical Chemistry, CAS Key Laboratory of Separation Sciences for Analytical Chemistry, Key Laboratory of Deep-sea Composition Detection Technology of Liaoning Province, Dalian Institute of Chemical Physics, CAS, 457 Zhongshan Road, Dalian 116023, China
| | - Xuhui Geng
- Department of Instrumentation & Analytical Chemistry, CAS Key Laboratory of Separation Sciences for Analytical Chemistry, Key Laboratory of Deep-sea Composition Detection Technology of Liaoning Province, Dalian Institute of Chemical Physics, CAS, 457 Zhongshan Road, Dalian 116023, China.
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Shandong Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China; School of Pharmacy, Binzhou Medical University, Yantai 264003, China
| | - Zhihua Song
- School of Pharmacy, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Yantai University, Yantai 264005, PR China.
| |
Collapse
|
8
|
Li J, Sun D, Wen Y, Chen X, Wang H, Li S, Song Z, Liu H, Ma J, Chen L. Molecularly imprinted polymers and porous organic frameworks based analytical methods for disinfection by-products in water and wastewater. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2024; 356:124249. [PMID: 38810677 DOI: 10.1016/j.envpol.2024.124249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 04/16/2024] [Accepted: 05/26/2024] [Indexed: 05/31/2024]
Abstract
Disinfection by-products (DBPs) with heritage toxicity, mutagenicity and carcinogenicity are one kind of important new pollutants, and their detection and removal in water and wastewater has become a common challenge facing mankind. Advanced functional materials with ideal selectivity, adsorption capacity and regeneration capacity provide hope for the determination of DBPs with low concentration levels and inherent molecular structural similarity. Among them, molecularly imprinted polymers (MIPs) are favored, owing to their predictable structure, specific recognition and wide applicability. Also, metal-organic frameworks (MOFs) and covalent-organic frameworks (COFs) with unique pore structure, large specific surface area and easy functionalization, attract increasing interest. Herein, we review recent advances in analytical methods based on the above-mentioned three functional materials for DBPs in water and wastewater. Firstly, MIPs, MOFs and COFs are briefly introduced. Secondly, MIPs, MOFs and COFs as extractants, recognition element and adsorbents, are comprehensively discussed. Combining the latest research progress of solid-phase extraction (SPE), sensor, adsorption and nanofiltration, typical examples on MIPs and MOFs/COFs based analytical and removal applications in water and wastewater are summarized. Finally, the application prospects and challenges of the three functional materials in DBPs analysis are proposed to promote the development of corresponding analytical methods.
Collapse
Affiliation(s)
- Jinhua Li
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Coastal Zone Ecological Environment Monitoring Technology and Equipment Shandong Engineering Research Center, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, China; College of Chemistry and Chemical Engineering, Yantai University, Yantai, 264005, China.
| | - Dani Sun
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Coastal Zone Ecological Environment Monitoring Technology and Equipment Shandong Engineering Research Center, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, China; College of Chemistry and Chemical Engineering, Yantai University, Yantai, 264005, China
| | - Yuhao Wen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Coastal Zone Ecological Environment Monitoring Technology and Equipment Shandong Engineering Research Center, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, China
| | - Xuan Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Coastal Zone Ecological Environment Monitoring Technology and Equipment Shandong Engineering Research Center, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, China
| | - Hongdan Wang
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Coastal Zone Ecological Environment Monitoring Technology and Equipment Shandong Engineering Research Center, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, China
| | - Shuang Li
- School of Environmental & Municipal Engineering, State-Local Joint Engineering Research Center of Urban Sewage Treatment and Resource Recovery, Qingdao University of Technology, Qingdao, 266033, China
| | - Zhihua Song
- School of Pharmacy, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Yantai University, Yantai, 264005, China
| | - Huitao Liu
- College of Chemistry and Chemical Engineering, Yantai University, Yantai, 264005, China
| | - Jiping Ma
- School of Environmental & Municipal Engineering, State-Local Joint Engineering Research Center of Urban Sewage Treatment and Resource Recovery, Qingdao University of Technology, Qingdao, 266033, China
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Coastal Zone Ecological Environment Monitoring Technology and Equipment Shandong Engineering Research Center, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, China; Laboratory for Marine Biology and Biotechnology, Qingdao Marine Science and Technology Center, Qingdao, 266237, China
| |
Collapse
|
9
|
Zhou C, Xi X, Liu X, Wen W, Zhang X, Wu Z, Wang S. In situ detection of dopamine in single living cells by molecularly imprinted polymer-functionalized nanoelectrodes. Biosens Bioelectron 2024; 257:116332. [PMID: 38677016 DOI: 10.1016/j.bios.2024.116332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 04/10/2024] [Accepted: 04/22/2024] [Indexed: 04/29/2024]
Abstract
In situ detection of dopamine (DA) at single-cell level is critical for exploring neurotransmitter-related biological processes and diseases. However, the low content of DA and a variety of distractors with similar oxidation potentials as DA in cells brought great challenges. Here, a sensitive and specific electrochemical nanosensor was proposed for in situ detection of DA in single living cells based on nanodiamond (ND) and molecularly imprinted polymer (MIP)-functionalized carbon fiber nanoelectrode (ND/MIP/CFNE). Due to its excellent electrocatalytic property, ND was modified to the surface of CFNE based on amide bonding. Compared with bare CFNE, ND-modified CFNE can enhance oxidation currents of DA by about 4-fold, improving signal-to-noise ratio and detection sensitivity. MIP was further electropolymerized on the surface of nanoelectrodes to achieve specific capture and recognition of DA, which could avoid the interference of complex matrix and analogs in cells. Taking advantage of the precise positioning capability of a single-cell analyzer and micromanipulator, ND/MIP/CFNE could be precisely inserted into different locations of single cells and monitor oxidation signal of DA. The concentration of DA in the cytoplasm of single pheochromocytoma (PC12) cell was measured to be about 0.4 μM, providing a sensitive and powerful method for single-cell detection. Furthermore, the nanoelectrodes can monitor the fluctuation of intracellular DA under drug stimulation, providing new ideas and methods for new drug development and efficacy evaluation.
Collapse
Affiliation(s)
- Cuiyu Zhou
- Hubei Key Laboratory for Precision Synthesis of Small Molecule Pharmaceuticals & Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules & College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, PR China
| | - Xiaoxue Xi
- Hubei Key Laboratory for Precision Synthesis of Small Molecule Pharmaceuticals & Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules & College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, PR China
| | - Xiong Liu
- Hubei Ecological Environmental Monitoring Center Station, Wuhan, 430000, PR China
| | - Wei Wen
- Hubei Key Laboratory for Precision Synthesis of Small Molecule Pharmaceuticals & Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules & College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, PR China.
| | - Xiuhua Zhang
- Hubei Key Laboratory for Precision Synthesis of Small Molecule Pharmaceuticals & Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules & College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, PR China
| | - Zhen Wu
- Hubei Key Laboratory for Precision Synthesis of Small Molecule Pharmaceuticals & Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules & College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, PR China.
| | - Shengfu Wang
- Hubei Key Laboratory for Precision Synthesis of Small Molecule Pharmaceuticals & Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules & College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, PR China
| |
Collapse
|
10
|
Xia YF, Yuan HQ, Qiao C, Li W, Wang R, Chen P, Li YX, Bao GM. Multifunctional Eu 3+-MOF for simultaneous quantification of malachite green and leuco-malachite green and efficient adsorption of malachite green. JOURNAL OF HAZARDOUS MATERIALS 2024; 465:133386. [PMID: 38160559 DOI: 10.1016/j.jhazmat.2023.133386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 12/08/2023] [Accepted: 12/26/2023] [Indexed: 01/03/2024]
Abstract
Multi-target detection combined with in-situ removal of contaminants is a challenging issue difficult to overcome. Herein, a dual-emissive Eu3+-metal organic framework (Eu3+-MOF) was constructed by pre-functionalization with a blue-emissive ligand and post-functionalization with red-emissive Eu3+ ions using a UiO-66 precursor. The fluorescence of the synthesized Eu3+-MOF is highly selective and sensitive toward malachite green (MG) and its metabolite leuco-malachite green (LMG), which are environmentally persistent and highly toxic to humans. The limit of detection of MG and LMG are 34.20 and 1.98 nM, respectively. Interestingly, the fluorescence of this Eu3+-MOF showed ratiometric but different responsive modes toward MG and LMG, which enabled the simultaneous quantification of MG and LMG. Furthermore, a paper-based sensor combined with the smartphone was fabricated, which facilitated not only the dual-channel detection of MG, but also its portable, visual, rapid, and intelligent determination. Furthermore, the high surface area of MOFs, together with the coordinate bonding interaction, π-π stacking, and electrostatic interaction sites, endows Eu3+-MOF with the efficient ability toward MG removal. This multifunctional Eu3+-MOF can be successfully used for trace detection, simultaneous determination of MG and LMG, as well as efficient removal of MG. Thus, it exhibits bright prospects for widespread applications in the field of food and environmental analysis.
Collapse
Affiliation(s)
- Yi-Fan Xia
- National "111″ Center for Cellular Regulation and Molecular Pharmaceutics, Key Laboratory of Fermentation Engineering (Ministry of Education), Hubei Key Laboratory of Industrial Microbiology, School of Food and Biological Engineering, Hubei University of Technology, Wuhan 430068, China
| | - Hou-Qun Yuan
- National "111″ Center for Cellular Regulation and Molecular Pharmaceutics, Key Laboratory of Fermentation Engineering (Ministry of Education), Hubei Key Laboratory of Industrial Microbiology, School of Food and Biological Engineering, Hubei University of Technology, Wuhan 430068, China.
| | - Chen Qiao
- National "111″ Center for Cellular Regulation and Molecular Pharmaceutics, Key Laboratory of Fermentation Engineering (Ministry of Education), Hubei Key Laboratory of Industrial Microbiology, School of Food and Biological Engineering, Hubei University of Technology, Wuhan 430068, China
| | - Wei Li
- College of Chemistry and Materials, Jiangxi Agricultural University, Nanchang 330045, China
| | - Ran Wang
- National "111″ Center for Cellular Regulation and Molecular Pharmaceutics, Key Laboratory of Fermentation Engineering (Ministry of Education), Hubei Key Laboratory of Industrial Microbiology, School of Food and Biological Engineering, Hubei University of Technology, Wuhan 430068, China
| | - Peiyao Chen
- National "111″ Center for Cellular Regulation and Molecular Pharmaceutics, Key Laboratory of Fermentation Engineering (Ministry of Education), Hubei Key Laboratory of Industrial Microbiology, School of Food and Biological Engineering, Hubei University of Technology, Wuhan 430068, China
| | - Yan-Xia Li
- College of Chemistry and Materials, Jiangxi Agricultural University, Nanchang 330045, China
| | - Guang-Ming Bao
- National "111″ Center for Cellular Regulation and Molecular Pharmaceutics, Key Laboratory of Fermentation Engineering (Ministry of Education), Hubei Key Laboratory of Industrial Microbiology, School of Food and Biological Engineering, Hubei University of Technology, Wuhan 430068, China.
| |
Collapse
|
11
|
Gu J, Han T, Peng X, Kang H, Dong L. Highly sensitive fluorescent probe and portable test strip based on polyacrylic acid functionalized quantum dots for rapid visual detection of malachite green. Talanta 2024; 268:125359. [PMID: 37952316 DOI: 10.1016/j.talanta.2023.125359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 10/15/2023] [Accepted: 10/26/2023] [Indexed: 11/14/2023]
Abstract
Malachite green (MG) has been banned in aquaculture by many countries due to its high carcinogenicity, high teratogenicity, and easy residue. However, it is cheap and efficient characteristics have made it difficult to eliminate in recent decades, so it is essential to develop a rapid and accurate detection method for MG. Here, a highly Sensitive fluorescent probe based on polyacrylic acid (PAA) functionalized CdSe/CdxZn1-xS quantum dots (QDs) was prepared for the determination of MG. QDs functionalized by PAA (QDs@PAA) were used as energy donors, and MG was used as energy acceptor to construct fluorescence resonance energy transfer (FRET) system. The fluorescence of QDs@PAA could be linearly quenched by MG in the range of 0.05 ⁓ 2 μM, and the detection limit was 0.011 μM. In addition, a small amount of QDs@PAA (30 μL) was printed on the solid substrate by inkjet printing technology to prepare fluorescent test strips. When the concentration of MG was 2 μM, the fluorescent test strips were quenched and the detection process could be completed within 10 s, demonstrating significant potential for rapid visual detection of MG.
Collapse
Affiliation(s)
- Jiashuai Gu
- Center for Smart Materials and Devices, State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Luoshi Road 122, Wuhan 430070, PR China
| | - Ting Han
- Center for Smart Materials and Devices, State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Luoshi Road 122, Wuhan 430070, PR China
| | - Xiangdong Peng
- Center for Smart Materials and Devices, State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Luoshi Road 122, Wuhan 430070, PR China
| | - Hong Kang
- Center for Smart Materials and Devices, State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Luoshi Road 122, Wuhan 430070, PR China
| | - Lijie Dong
- Center for Smart Materials and Devices, State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Luoshi Road 122, Wuhan 430070, PR China; Hainan Institute, Wuhan University of Technology, Sanya 572000, PR China.
| |
Collapse
|