1
|
Knox A, Zerna G, Beddoe T. Current and Future Advances in the Detection and Surveillance of Biosecurity-Relevant Equine Bacterial Diseases Using Loop-Mediated Isothermal Amplification (LAMP). Animals (Basel) 2023; 13:2663. [PMID: 37627456 PMCID: PMC10451754 DOI: 10.3390/ani13162663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 08/13/2023] [Accepted: 08/15/2023] [Indexed: 08/27/2023] Open
Abstract
Horses play an important role throughout the world, whether for work, culture, or leisure, providing an ever-growing significant contribution to the economy. The increase in importation and movement of horses, both nationally and internationally, has inevitably allowed for the global equine industry to grow. Subsequently, however, the potential for transmission of fatal equine bacterial diseases has also escalated, and devasting outbreaks continue to occur. To prevent such events, disease surveillance and diagnosis must be heightened throughout the industry. Current common, or "gold-standard" techniques, have shown to be inadequate at times, thus requiring newer technology to impede outbreaks. Loop-mediated isothermal amplification (LAMP) has proven to be a reliable, rapid, and accessible tool in both diagnostics and surveillance. This review will discuss equine bacterial diseases of biosecurity relevance and their current diagnostic approaches, as well as their respective LAMP assay developments. Additionally, we will provide insight regarding newer technology and advancements associated with this technique and their potential use for the outlined diseases.
Collapse
Affiliation(s)
| | | | - Travis Beddoe
- Department of Animal, Plant and Soil Sciences, Centre for AgriBioscience, La Trobe University, Bundoora, VIC 3082, Australia; (A.K.); (G.Z.)
| |
Collapse
|
2
|
Jauset-Rubio M, Ortiz M, O'Sullivan CK. Solid-Phase Primer Elongation Using Biotinylated dNTPs for the Detection of a Single Nucleotide Polymorphism from a Fingerprick Blood Sample. Anal Chem 2021; 93:14578-14585. [PMID: 34704755 PMCID: PMC8581964 DOI: 10.1021/acs.analchem.1c03419] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Isothermal recombinase polymerase amplification-based solid-phase primer extension is used for the optical detection of a hypertrophic cardiomyopathy associated single nucleotide polymorphism (SNP) in a fingerprick blood sample. The assay exploits four thiolated primers which have the same sequences with the exception of the 3'-terminal base. Target DNA containing the SNP site hybridizes to all four of the immobilized probes, with primer extension only taking place from the primer containing the terminal base that is complementary to the SNP under interrogation. Biotinylated deoxynucleotide triphosphates are used in the primer extension, allowing postextension addition of streptavidin-poly-horseradish peroxidase to bind to the incorporated biotinylated dNTPs. The signal generated following substrate addition can then be measured optically. The percentage of biotinylated dNTPs and the duration of primer extension is optimized and the system applied to the identification of a SNP in a fingerprick blood sample. A methodology of thermal lysis using a 1 in 5 dilution of the fingerprick blood sample prior to application of 95 °C for 30 s is used to extract genomic DNA, which is directly used as a template for solid-phase primer extension on microtiter plates, followed by optical detection. The SNP in the fingerprick sample was identified and its identity corroborated using ion torrent next generation sequencing. Ongoing work is focused on extension to the multiplexed detection of SNPs in fingerprick and other biological samples.
Collapse
Affiliation(s)
- Miriam Jauset-Rubio
- INTERFIBIO Research Group, Departament d'Enginyeria Química, Universitat Rovira i Virgili, Avinguda Països Catalans 26, 43007 Tarragona, Spain
| | - Mayreli Ortiz
- INTERFIBIO Research Group, Departament d'Enginyeria Química, Universitat Rovira i Virgili, Avinguda Països Catalans 26, 43007 Tarragona, Spain
| | - Ciara K O'Sullivan
- INTERFIBIO Research Group, Departament d'Enginyeria Química, Universitat Rovira i Virgili, Avinguda Països Catalans 26, 43007 Tarragona, Spain.,InstitucióCatalana de Recerca i Estudis Avancats (ICREA), Passeig Lluís Companys 23, 08010 Barcelona, Spain
| |
Collapse
|
3
|
Singh M, Pal D, Sood P, Randhawa G. Construct-Specific Loop-Mediated Isothermal Amplification: Rapid Detection of Genetically Modified Crops with Insect Resistance or Herbicide Tolerance. J AOAC Int 2021; 103:1191-1200. [PMID: 33241393 DOI: 10.1093/jaoacint/qsaa043] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Revised: 03/16/2020] [Accepted: 03/17/2020] [Indexed: 12/14/2022]
Abstract
BACKGROUND Insect resistant and herbicide tolerant genetically modified (GM) events have been approved in many countries. Screening methods could facilitate preliminary testing to check the GM status, which may target control elements, transgenes, and marker genes or construct regions. Among these, methods targeting the construct region, i.e., the junction between two genetic elements of a transgenic cassette are more specific. OBJECTIVE Loop-mediated isothermal amplification (LAMP) assays targeting three construct regions were developed; between Cauliflower Mosaic Virus 35S promoter and cry1Ac gene (p35S-cry1Ac), cry2Ab2 gene and nos terminator (cry2Ab2-tnos), and cp4-epsps gene and nos terminator (cp4epsps-tnos). METHOD LAMP assays were performed by incubation at constant temperatures for selected targets. Positive amplification was detected as a change in color from orange to green on addition of SYBR® Green dye in visual LAMP and as real-time amplification curves in real-time LAMP. RESULTS These assays showed acceptable specificity and sensitivity. Visual LAMP was found to be sensitive enough to detect as low as 0.005%, equivalent to two target copies. Real-time LAMP assays were able to detect as low as four copies of the target within 40 min, making them suitable for rapid on-site testing for GM organisms (GMO). Practical utility was also verified using spiked test samples. CONCLUSIONS These assays could be employed to address some of the biosafety or post-release monitoring issues, as well as to check for approved and unapproved GM events in a country. HIGHLIGHTS LAMP assays targeting three construct regions have been developed, enabling screening for approved or unapproved GMO.
Collapse
Affiliation(s)
- Monika Singh
- ICAR-National Bureau of Plant Genetic Resources, Division of Genomic Resources, New Delhi 110 012, India
| | - Deepa Pal
- ICAR-National Bureau of Plant Genetic Resources, Division of Genomic Resources, New Delhi 110 012, India
| | - Payal Sood
- ICAR-National Bureau of Plant Genetic Resources, Division of Genomic Resources, New Delhi 110 012, India
| | - Gurinderjit Randhawa
- ICAR-National Bureau of Plant Genetic Resources, Division of Genomic Resources, New Delhi 110 012, India
| |
Collapse
|
4
|
Wang X, Chen Y, Chen X, Peng C, Wang L, Xu X, Wu J, Wei W, Xu J. A highly integrated system with rapid DNA extraction, recombinase polymerase amplification, and lateral flow biosensor for on-site detection of genetically modified crops. Anal Chim Acta 2020; 1109:158-168. [PMID: 32252899 DOI: 10.1016/j.aca.2020.02.044] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 02/21/2020] [Accepted: 02/22/2020] [Indexed: 01/29/2023]
Abstract
With the large-scale planting of genetically modified (GM) crops, the development of a rapid and convenient method for on-site monitoring GM crops is needed. In this study, a duplex recombinase polymerase amplification (DRPA)-based, quick and simple detection system is presented for on-site detection of GM crops. In this system, a rapid DNA extraction method, a DRPA, and a lateral flow biosensor (LFB) are integrated to allow for rapid DNA extraction and amplification, and fast visualization of the detection results. Using the rapid DNA extraction method, high-quality DNA suitable for RPA and polymerase chain reaction (PCR) was quickly isolated from various crops within 5 min. Utilizing the optimal DRPA assay, the universal screening sequences (Cauliflower mosaic virus 35S promoter [35S] and Agrobacterium tumefaciens NOS terminator [NOS]) were rapidly and simultaneously amplified with high selectivity and sensitivity. The sensitivity threshold of the DRPA assay was ∼10 copies for GM soybean genomic DNA and 100 ng DNA of 0.1% GM soybean. In combination with the LFB in an enclosed cassette, the entire detection process was performed in approximately 20-30 min and eliminated the carryover contamination. No special or expensive equipment was needed for the detection process. The system was successfully applied and validated for on-site detection of GM rice, demonstrating its suitability for on-site testing of GM crops and high potential for application to other fields, especially in low-resource regions that require rapid detection of DNA targets.
Collapse
Affiliation(s)
- Xiaofu Wang
- State Key Laboratory for Quality and Safety of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou, 310021, China; Key Laboratory of Information Traceability for Agricultural Products, Ministry of Agriculture of China, Hangzhou, 310021, China
| | - Yu Chen
- State Key Laboratory for Quality and Safety of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou, 310021, China; College of Chemistry and Life Science, Shenyang Normal University, Shenyang, 110034, China
| | - Xiaoyun Chen
- State Key Laboratory for Quality and Safety of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou, 310021, China
| | - Cheng Peng
- State Key Laboratory for Quality and Safety of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou, 310021, China; Key Laboratory of Information Traceability for Agricultural Products, Ministry of Agriculture of China, Hangzhou, 310021, China
| | - Liu Wang
- State Key Laboratory for Quality and Safety of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou, 310021, China
| | - Xiaoli Xu
- State Key Laboratory for Quality and Safety of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou, 310021, China
| | - Jian Wu
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, China
| | - Wei Wei
- State Key Laboratory for Quality and Safety of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou, 310021, China; Key Laboratory of Information Traceability for Agricultural Products, Ministry of Agriculture of China, Hangzhou, 310021, China
| | - Junfeng Xu
- State Key Laboratory for Quality and Safety of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou, 310021, China.
| |
Collapse
|
5
|
Kumar R, Kaundal P, Arjunan J, Sharma S, Chakrabarti SK. Development of a visual detection method for Potato virus S by reverse transcription loop-mediated isothermal amplification. 3 Biotech 2020; 10:213. [PMID: 32351871 PMCID: PMC7182647 DOI: 10.1007/s13205-020-02214-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Accepted: 04/16/2020] [Indexed: 12/12/2022] Open
Abstract
A reverse transcription-loop mediated isothermal amplification (RT-LAMP) assay was developed to detect the Potato virus S (PVS) in potato. Two sets of six novel primers that recognize the coat protein gene sequence of the PVS were designed and RT-LAMP assay was optimized for the parameters such as different concentrations of primers, MgSO4, betaine, dNTPs, Bst DNA polymerase, temperature and duration. The RT-LAMP was carried out under isothermal conditions without the thermal cycler using PVS infected leaf and tuber samples, LAMP specific primers with amplification at 65 °C for 60 min, and 80 °C for 5 min. The results were assessed by gel electrophoresis and visual observation of colour change using SYBR Green I dye. The detection limit of the developed RT-LAMP assay was determined and compared with a conventional reverse transcription-polymerase chain reaction (RT-PCR). RT-LAMP was found 100 times more sensitive than RT-PCR. The optimized RT-LAMP assay is robust, reliable, sensitive and convenient for the detection of the PVS in infected potato tubers including asymptomatic plants. No cross-reactions were observed with healthy plants and other potato viruses. The assay is economical and can be employed in large scale testing of potato plants against PVS under healthy seed potato production programme.
Collapse
Affiliation(s)
- Ravinder Kumar
- 1ICAR-Central Potato Research Institute, Shimla, HP 171 001 India
| | - Priyanka Kaundal
- 1ICAR-Central Potato Research Institute, Shimla, HP 171 001 India
| | - Jeevalatha Arjunan
- 2ICAR-Indian Institute of Spices Research, Marikunnu P.O., Kozhikode, Kerala 673 012 India
| | - Sanjeev Sharma
- 1ICAR-Central Potato Research Institute, Shimla, HP 171 001 India
| | - S K Chakrabarti
- 1ICAR-Central Potato Research Institute, Shimla, HP 171 001 India
| |
Collapse
|
6
|
Wu H, Zhang X, Wu B, Qian C, Zhang F, Wang L, Ye Z, Wu J. Rapid on-site detection of genetically modified soybean products by real-time loop-mediated isothermal amplification coupled with a designed portable amplifier. Food Chem 2020; 323:126819. [PMID: 32334306 DOI: 10.1016/j.foodchem.2020.126819] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 04/06/2020] [Accepted: 04/13/2020] [Indexed: 12/29/2022]
Abstract
Herein, we developed a rapid method for detection of genetically modified soybean (GTS 40-3-2) products using loop-mediated isothermal amplification (LAMP). A crude 5-minute extraction method was established for DNA extraction from soybeans and soybean products. LAMP reaction for CaMV35S promoter was optimized and the fastest threshold time (Tt) was 14 min with 4 mM magnesium ions at 63 °C. A portable instrument was designed to perform real-time LAMP in the field. As little as 0.1% GM soybean, specifically, or 0.5% GM ingredients in Chinese traditional tofu could be detected in 30 min from sampling to results. We used this method to further assess other five soybean products to determine whether they contained transgenic ingredients and compared the results with those obtained using PCR, which suggested the proposed method was applicable for rapid detection of genetically modified soybean in food products.
Collapse
Affiliation(s)
- Hui Wu
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China
| | - Xianjun Zhang
- Hangzhou An Yu Technologies Co.,Ltd., Hangzhou 310021, China
| | - Baoqiang Wu
- Hangzhou An Yu Technologies Co.,Ltd., Hangzhou 310021, China
| | - Cheng Qian
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China
| | - Fang Zhang
- College of Biological Science and Engineering, Fuzhou University, Fuzhou 350108, China
| | - Liu Wang
- Institute of Quality and Standard for Agro-products, Zhejiang Academy of Agricultural Sciences, State Key Laboratory for Quality and Safety of Agro-products, Hangzhou 310021, China.
| | - Zunzhong Ye
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China.
| | - Jian Wu
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China
| |
Collapse
|
7
|
Panno S, Matić S, Tiberini A, Caruso AG, Bella P, Torta L, Stassi R, Davino S. Loop Mediated Isothermal Amplification: Principles and Applications in Plant Virology. PLANTS (BASEL, SWITZERLAND) 2020; 9:E461. [PMID: 32268586 PMCID: PMC7238132 DOI: 10.3390/plants9040461] [Citation(s) in RCA: 76] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Revised: 04/02/2020] [Accepted: 04/02/2020] [Indexed: 01/14/2023]
Abstract
In the last decades, the evolution of molecular diagnosis methods has generated different advanced tools, like loop-mediated isothermal amplification (LAMP). Currently, it is a well-established technique, applied in different fields, such as the medicine, agriculture, and food industries, owing to its simplicity, specificity, rapidity, and low-cost efforts. LAMP is a nucleic acid amplification under isothermal conditions, which is highly compatible with point-of-care (POC) analysis and has the potential to improve the diagnosis in plant protection. The great advantages of LAMP have led to several upgrades in order to implement the technique. In this review, the authors provide an overview reporting in detail the different LAMP steps, focusing on designing and main characteristics of the primer set, different methods of result visualization, evolution and different application fields, reporting in detail LAMP application in plant virology, and the main advantages of the use of this technique.
Collapse
Affiliation(s)
- Stefano Panno
- Department of Agricultural, Food and Forest Sciences, University of Palermo, 90128 Palermo, Italy; (A.G.C.); (P.B.); (L.T.); (R.S.)
| | - Slavica Matić
- Department of Agricultural, Forestry and Food Sciences, University of Turin, 10095 Turin, Italy;
| | - Antonio Tiberini
- Council for Agricultural Research and Economics, Research Center for Plant Protection and Certification, 00156 Rome, Italy;
| | - Andrea Giovanni Caruso
- Department of Agricultural, Food and Forest Sciences, University of Palermo, 90128 Palermo, Italy; (A.G.C.); (P.B.); (L.T.); (R.S.)
| | - Patrizia Bella
- Department of Agricultural, Food and Forest Sciences, University of Palermo, 90128 Palermo, Italy; (A.G.C.); (P.B.); (L.T.); (R.S.)
| | - Livio Torta
- Department of Agricultural, Food and Forest Sciences, University of Palermo, 90128 Palermo, Italy; (A.G.C.); (P.B.); (L.T.); (R.S.)
| | - Raffaele Stassi
- Department of Agricultural, Food and Forest Sciences, University of Palermo, 90128 Palermo, Italy; (A.G.C.); (P.B.); (L.T.); (R.S.)
| | - Salvatore Davino
- Department of Agricultural, Food and Forest Sciences, University of Palermo, 90128 Palermo, Italy; (A.G.C.); (P.B.); (L.T.); (R.S.)
- Institute for Sustainable Plant Protection, National Research Council (IPSP-CNR), 10135 Turin, Italy
| |
Collapse
|
8
|
Singh M, Pal D, Sood P, Randhawa G. Loop-mediated isothermal amplification assays: Rapid and efficient diagnostics for genetically modified crops. Food Control 2019. [DOI: 10.1016/j.foodcont.2019.106759] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
9
|
Abudayyeh OO, Gootenberg JS, Kellner MJ, Zhang F. Nucleic Acid Detection of Plant Genes Using CRISPR-Cas13. CRISPR J 2019; 2:165-171. [PMID: 31225754 PMCID: PMC7001462 DOI: 10.1089/crispr.2019.0011] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Nucleic acid detection is vital for agricultural applications including trait detection during breeding, pest surveillance, and pathogen identification. Here, we use a modified version of the CRISPR-based nucleic acid detection platform SHERLOCK to quantify levels of a glyphosate resistance gene in a mixture of soybeans and to detect multiple plant genes in a single reaction. SHERLOCK is rapid (∼15 min), quantitative, and portable, and can process crude soybean extracts as input material for minimal nucleic acid sample preparation. This field-ready SHERLOCK platform with color-based lateral flow readout can be applied for detection and quantitation of genes in a range of agricultural applications.
Collapse
Affiliation(s)
- Omar O. Abudayyeh
- Broad Institute of MIT and Harvard, Cambridge, Massachusetts; Harvard Medical School, Boston, Massachusetts
- McGovern Institute for Brain Research at MIT, Cambridge, Massachusetts; Departments of Harvard Medical School, Boston, Massachusetts
- Brain and Cognitive Science, Harvard Medical School, Boston, Massachusetts
- Biological Engineering, and Harvard Medical School, Boston, Massachusetts
- Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts; Harvard Medical School, Boston, Massachusetts
| | - Jonathan S. Gootenberg
- Broad Institute of MIT and Harvard, Cambridge, Massachusetts; Harvard Medical School, Boston, Massachusetts
- McGovern Institute for Brain Research at MIT, Cambridge, Massachusetts; Departments of Harvard Medical School, Boston, Massachusetts
- Brain and Cognitive Science, Harvard Medical School, Boston, Massachusetts
- Biological Engineering, and Harvard Medical School, Boston, Massachusetts
- Department of Systems Biology, Harvard Medical School, Boston, Massachusetts
| | - Max J. Kellner
- Broad Institute of MIT and Harvard, Cambridge, Massachusetts; Harvard Medical School, Boston, Massachusetts
| | - Feng Zhang
- Broad Institute of MIT and Harvard, Cambridge, Massachusetts; Harvard Medical School, Boston, Massachusetts
- McGovern Institute for Brain Research at MIT, Cambridge, Massachusetts; Departments of Harvard Medical School, Boston, Massachusetts
- Brain and Cognitive Science, Harvard Medical School, Boston, Massachusetts
- Biological Engineering, and Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
10
|
Zhang H, Xu Y, Fohlerova Z, Chang H, Iliescu C, Neuzil P. LAMP-on-a-chip: Revising microfluidic platforms for loop-mediated DNA amplification. Trends Analyt Chem 2019; 113:44-53. [PMID: 32287531 PMCID: PMC7112807 DOI: 10.1016/j.trac.2019.01.015] [Citation(s) in RCA: 126] [Impact Index Per Article: 25.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Nucleic acid amplification for the detection of infectious diseases, food pathogens, or assessment of genetic disorders require a laboratory setting with specialized equipment and technical expertise. Isothermal deoxyribonucleic acid amplification methods, such as loop-mediated isothermal amplification (LAMP), exhibit characteristics ideal for point-of-care (POC) applications, since their instrumentation is simpler in comparison with the standard method of polymerase chain reaction. Other key advantages of LAMP are robustness and the production of pyrophosphate in the presence of the target gene, enabling to detect the reaction products using the naked eye. Polymerase inhibitors, presented in clinical samples, do not affect the amplification process, making LAMP suitable for a simple sample-to-answer diagnostic systems with simplified sample preparation. In this review, we discuss the trends in miniaturized LAMP techniques, such as microfluidic, paper-based, and digital with their advantages and disadvantages, especially for POC applications alongside our opinion of the future development of miniaturized LAMP. Introduction of loop mediated isothermal amplification (LAMP) and its principle. Classical microfluidics-based LAMP for DNA/RNA detection. Paper-based LAMP. Microfluidic-based digital LAMP. Future of microfluidic LAMP development.
Collapse
Affiliation(s)
- Haoqing Zhang
- Northwestern Polytechnical University, School of Mechanical Engineering, Department of Microsystem Engineering, 127 West Youyi Road, Xi'an, Shaanxi, 710072, PR China
| | - Ying Xu
- Northwestern Polytechnical University, School of Mechanical Engineering, Department of Microsystem Engineering, 127 West Youyi Road, Xi'an, Shaanxi, 710072, PR China
| | - Zdenka Fohlerova
- Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61300 Brno, Czech Republic.,Faculty of Electrical Engineering, Brno University of Technology, Technická 3058/10, 61600 Brno, Czech Republic
| | - Honglong Chang
- Northwestern Polytechnical University, School of Mechanical Engineering, Department of Microsystem Engineering, 127 West Youyi Road, Xi'an, Shaanxi, 710072, PR China
| | - Ciprian Iliescu
- Biomedical Institute for Global Health Research and Technology (BIGHEART), National University of Singapore, MD6, 14 Medical Drive #14-01, 117599, Singapore
| | - Pavel Neuzil
- Northwestern Polytechnical University, School of Mechanical Engineering, Department of Microsystem Engineering, 127 West Youyi Road, Xi'an, Shaanxi, 710072, PR China.,Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61300 Brno, Czech Republic
| |
Collapse
|
11
|
Fu S, Jiang Y, Jiang X, Zhao Y, Chen S, Yang X, Man C. Probe-free label system for rapid detection of Cronobacter genus in powdered infant formula. AMB Express 2018; 8:155. [PMID: 30269246 PMCID: PMC6163125 DOI: 10.1186/s13568-018-0689-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2018] [Accepted: 09/26/2018] [Indexed: 02/08/2023] Open
Abstract
Cronobacter species previously known as Enterobacter sakazakii poses high risks to neonates and infants. In this work a rapid detection method was developed which combined loop-mediated isothermal amplification with lateral flow assay for detection of Cronobacter species in powdered infant formula. The fast amplification reaction without betaine was established and capable of performing DNA replication within 25 min. Based on the novel probe-free labeling methods, we established a lateral flow assay to capture the specific loop-mediated isothermal amplification amplicons which were labeled with fluorescein isothiocyanate and biotin. And the final detection time of this system was within 40 min. The false positive results of the lateral flow assay induced by primer dimer tagged with fluorescein isothiocyanate and biotin were eliminated by Taq single strand DNA binding protein (4 ng/μL). Simultaneously, the efficiency of the fast loop-mediated isothermal amplification assay was achieved. By injection of Taq SSB into the amplification assay as a replacement for betaine, the novel probe-free method could detect Cronobacter species with high specificity and sensitivity at the detection limit in PIF of 101 cfu/g. Our overall strategy has excellent potential in the rapid diagnosis of Cronobacter species label-free by integrating loop-mediated isothermal amplification and lateral flow assay.
Collapse
|
12
|
Huang HL, Zhu P, Zhou CX, Yan XJ, Zou YX, Lv PW. Detection of Skeletonema costatum based on loop-mediated isothermal amplification combined with lateral flow dipstick. Mol Cell Probes 2017; 36:36-42. [PMID: 28826997 DOI: 10.1016/j.mcp.2017.08.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2017] [Revised: 07/22/2017] [Accepted: 08/15/2017] [Indexed: 11/27/2022]
Abstract
We developed a new assay method, which combines loop-mediated isothermal amplification (LAMP) with a chromatographic lateral flow dipstick (LFD) for the rapid and special detection of the diatom Skeletonema costatum. Four groups of LAMP primers were derived from a conserved DNA sequence unique to S. costatum. The amplifications were carried out at 61, 63, and 65 °C for 60 min in various combinations by the quantitative PCR thermal cycler to confirm optimal primers and reaction temperature. The LAMP-LFD detection limit was 0.94 pg/μL of S. costatum genomic DNA and was 100 times more sensitive than conventional PCR. The LAMP-LFD method had high specificity and accurately identified S. costatum algal isolates, but not other algal isolates. The new LAMP-LFD assay can be used as a reliable and easy method to detect S. costatum.
Collapse
Affiliation(s)
- Hai-Long Huang
- Key Laboratory of Applied Marine Biotechnology, Ningbo University, Ningbo 315211, China.
| | - Peng Zhu
- Key Laboratory of Applied Marine Biotechnology, Ningbo University, Ningbo 315211, China.
| | - Cheng-Xu Zhou
- Key Laboratory of Applied Marine Biotechnology, Ningbo University, Ningbo 315211, China.
| | - Xiao-Jun Yan
- Key Laboratory of Applied Marine Biotechnology, Ningbo University, Ningbo 315211, China.
| | - Yi-Xin Zou
- Key Laboratory of Applied Marine Biotechnology, Ningbo University, Ningbo 315211, China.
| | - Pei-Wen Lv
- Key Laboratory of Applied Marine Biotechnology, Ningbo University, Ningbo 315211, China.
| |
Collapse
|
13
|
Kumvongpin R, Jearanaikoon P, Wilailuckana C, Sae-Ung N, Prasongdee P, Daduang S, Wongsena M, Boonsiri P, Kiatpathomchai W, Swangvaree SS, Sandee A, Daduang J. Detection assay for HPV16 and HPV18 by loop-mediated isothermal amplification with lateral flow dipstick tests. Mol Med Rep 2017; 15:3203-3209. [DOI: 10.3892/mmr.2017.6370] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Accepted: 01/27/2017] [Indexed: 11/06/2022] Open
|
14
|
Li Y, Fan P, Zhou S, Zhang L. Loop-mediated isothermal amplification (LAMP): A novel rapid detection platform for pathogens. Microb Pathog 2017; 107:54-61. [PMID: 28323152 DOI: 10.1016/j.micpath.2017.03.016] [Citation(s) in RCA: 134] [Impact Index Per Article: 19.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2017] [Revised: 03/07/2017] [Accepted: 03/16/2017] [Indexed: 12/12/2022]
Abstract
Foodborne bacterial infections and diseases have been considered to be a major threat for public health in the worldwide. Increased incidence of human diseases caused by foodborne pathogens have been correlated with growing world population and mobility. Loop-mediated isothermal amplification (LAMP) has been regarded as an innovative gene amplification technology and emerged as an alternative to PCR-based methodologies in both clinical laboratory and food safety testing. Nowadays, LAMP has been applied to detection and identification on pathogens from microbial diseases, as it showed significant advantage in high sensitivity, specificity and rapidity. The high sensitivity of LAMP enables detection of the pathogens in sample materials even without time consuming sample preparation. An overview of LAMP mainly containing the development history, reaction principle and its application to four kind of foodborne pathogens detection are presented in this paper. As concluded, with the advantages of rapidity, simplicity, sensitivity, specificity and robustness, LAMP is capable of applications for clinical diagnosis as well as surveillance of infection diseases. Moreover, the main purpose of this paper is to provide theoretical basis for the clinical application of LAMP technology.
Collapse
Affiliation(s)
- Yanmei Li
- Department of Haematology, Guangzhou Women and Children's Medical Centre, Guangzhou Medical University, Guangzhou 510623, PR China.
| | - Penghui Fan
- School of Food Science and Engineering, South China University of Technology, Guangzhou 510640, PR China.
| | - Shishui Zhou
- School of Bioscience and Bioengineering, South China University of Technology, 382 Zhonghuan Road East, Guangzhou 510006, PR China.
| | - Li Zhang
- Department of Haematology, Guangzhou Women and Children's Medical Centre, Guangzhou Medical University, Guangzhou 510623, PR China.
| |
Collapse
|
15
|
Huang HL, Zhu P, Zhou CX, He S, Yan XJ. The development of loop-mediated isothermal amplification combined with lateral flow dipstick for detection of Karlodinium veneficum. HARMFUL ALGAE 2017; 62:20-29. [PMID: 28118889 DOI: 10.1016/j.hal.2016.11.022] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2016] [Revised: 11/29/2016] [Accepted: 11/29/2016] [Indexed: 05/04/2023]
Abstract
The aim of this study was to develop a loop-mediated isothermal amplification (LAMP) combined with a chromatographic lateral flow dipstick (LFD) assay to rapidly and specifically detect the Karlodinium veneficum ITS gene. Four groups of LAMP primers were specially designed to target the K. veneficum ITS gene. The LAMP-LFD detection limit was 7.4pg/μL (approximately 6.5cells/mL) of K. veneficum genomic DNA and was 10 times more sensitive than standard PCR. The LAMP-LFD method exhibited high specificity and accurately identified K. veneficum algal isolates, but not other algal isolates. To test the assay's accuracy, samples from positive results were further analyzed by sequencing and phylogenetic analysis, all of which were identified as K. veneficum. Over all, the LAMP-LFD assay established in this paper can be used as a reliable and simple method to detect the K. veneficum.
Collapse
Affiliation(s)
- Hai-Long Huang
- Key Laboratory of Applied Marine Biotechnology, Ningbo University, Ningbo 315211, China.
| | - Peng Zhu
- Key Laboratory of Applied Marine Biotechnology, Ningbo University, Ningbo 315211, China.
| | - Cheng-Xu Zhou
- Key Laboratory of Applied Marine Biotechnology, Ningbo University, Ningbo 315211, China.
| | - Shan He
- Key Laboratory of Applied Marine Biotechnology, Ningbo University, Ningbo 315211, China.
| | - Xiao-Jun Yan
- Key Laboratory of Applied Marine Biotechnology, Ningbo University, Ningbo 315211, China.
| |
Collapse
|
16
|
Real-time and visual loop-mediated isothermal amplification: Efficient GMO screening targeting pat and pmi marker genes. Food Control 2017. [DOI: 10.1016/j.foodcont.2016.06.027] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
17
|
Shen P, Geng F, Yu Y, Zhang Y, Wang Z, Li Z, Zhang W, Shu C, Zhang Y, Tan J. A rapid loop-mediated isothermal amplification method for detection of the modified GM cry1A gene in transgenic insect-resistant cotton and rice. Food Control 2016. [DOI: 10.1016/j.foodcont.2015.10.035] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
18
|
Safavieh M, Kanakasabapathy MK, Tarlan F, Ahmed MU, Zourob M, Asghar W, Shafiee H. Emerging Loop-Mediated Isothermal Amplification-Based Microchip and Microdevice Technologies for Nucleic Acid Detection. ACS Biomater Sci Eng 2016; 2:278-294. [PMID: 28503658 PMCID: PMC5425166 DOI: 10.1021/acsbiomaterials.5b00449] [Citation(s) in RCA: 111] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Rapid, sensitive, and selective pathogen detection is of paramount importance in infectious disease diagnosis and treatment monitoring. Currently available diagnostic assays based on polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay (ELISA) are time-consuming, complex, and relatively expensive, thus limiting their utility in resource-limited settings. Loop-mediated isothermal amplification (LAMP) technique has been used extensively in the development of rapid and sensitive diagnostic assays for pathogen detection and nucleic acid analysis and hold great promise for revolutionizing point-of-care molecular diagnostics. Here, we review novel LAMP-based lab-on-a-chip (LOC) diagnostic assays developed for pathogen detection over the past several years. We review various LOC platforms based on their design strategies for pathogen detection and discuss LAMP-based platforms still in development and already in the commercial pipeline. This review is intended as a guide to the use of LAMP techniques in LOC platforms for molecular diagnostics and genomic amplifications.
Collapse
Affiliation(s)
- Mohammadali Safavieh
- Division of Biomedical Engineering, Division of Renal Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, 65 Lansdowne Street, Cambridge, Massachusetts 02139, United States
| | - Manoj K. Kanakasabapathy
- Division of Biomedical Engineering, Division of Renal Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, 65 Lansdowne Street, Cambridge, Massachusetts 02139, United States
| | - Farhang Tarlan
- Division of Biomedical Engineering, Division of Renal Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, 65 Lansdowne Street, Cambridge, Massachusetts 02139, United States
| | - Minhaz U. Ahmed
- Biosensors and Biotechnology Laboratory, Faculty of Science, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong, Negara Brunei Darussalam
| | - Mohammed Zourob
- Department of Chemistry, College of Science, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Rd, Riyadh 11533, Saudi Arabia
| | - Waseem Asghar
- Department of Computer Engineering & Electrical Engineering and Computer Science, Florida Atlantic University, 777 Glades Road, Boca Raton, Florida 33431, United States
| | - Hadi Shafiee
- Division of Biomedical Engineering, Division of Renal Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, 65 Lansdowne Street, Cambridge, Massachusetts 02139, United States
| |
Collapse
|
19
|
Bhoge RK, Chhabra R, Randhawa G, Sathiyabama M, Singh M. Event-specific analytical methods for six genetically modified maize events using visual and real-time loop-mediated isothermal amplification. Food Control 2015. [DOI: 10.1016/j.foodcont.2015.02.016] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
20
|
Jeong J, Cho SY, Lee WH, Lee KJ, Ju HJ. Development of a Rapid Detection Method for Potato virus X by Reverse Transcription Loop-Mediated Isothermal Amplification. THE PLANT PATHOLOGY JOURNAL 2015; 31:219-25. [PMID: 26361470 PMCID: PMC4564147 DOI: 10.5423/ppj.oa.03.2015.0044] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2015] [Revised: 05/05/2015] [Accepted: 05/10/2015] [Indexed: 05/10/2023]
Abstract
The primary step for efficient control of viral diseases is the development of simple, rapid, and sensitive virus detection. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) has been used to detect viral RNA molecules because of its simplicity and high sensitivity for a number of viruses. RT-LAMP for the detection of Potato virus X (PVX) was developed and compared with conventional reverse transcription polymerase chain reaction (RT-PCR) to demonstrate its advantages over RT-PCR. RT-LAMP reactions were conducted with or without a set of loop primers since one out of six primers showed PVX specificity. Based on real-time monitoring, RT-LAMP detected PVX around 30 min, compared to 120 min for RT-PCR. By adding a fluorescent reagent during the reaction, the extra step of visualization by gel electrophoresis was not necessary. RT-LAMP was conducted using simple inexpensive instruments and a regular incubator to evaluate whether RNA could be amplified at a constant temperature instead of using an expensive thermal cycler. This study shows the potential of RT-LAMP for the diagnosis of viral diseases and PVX epidemiology because of its simplicity and rapidness compared to RT-PCR.
Collapse
Affiliation(s)
- Joojin Jeong
- Department of Agricultural Biology, College of Agriculture & Life Sciences, Chonbuk National University, Jeonju-si 561-756,
Korea
| | - Sang-Yun Cho
- Department of Agricultural Biology, College of Agriculture & Life Sciences, Chonbuk National University, Jeonju-si 561-756,
Korea
| | - Wang-Hyu Lee
- Department of Agricultural Biology, College of Agriculture & Life Sciences, Chonbuk National University, Jeonju-si 561-756,
Korea
| | - Kui-jae Lee
- Division of Biotechnology, Chonbuk National University, Iksan 570-752,
Korea
- Plant Medicinal Research Center, College of Agriculture & Life Sciences, Chonbuk National University, Jeonju-si 561-756,
Korea
| | - Ho-Jong Ju
- Department of Agricultural Biology, College of Agriculture & Life Sciences, Chonbuk National University, Jeonju-si 561-756,
Korea
- Plant Medicinal Research Center, College of Agriculture & Life Sciences, Chonbuk National University, Jeonju-si 561-756,
Korea
| |
Collapse
|
21
|
Singh M, Randhawa GJ, Sood P, Bhoge RK. Loop-mediated isothermal amplification targeting insect resistant and herbicide tolerant transgenes: Monitoring for GM contamination in supply chain. Food Control 2015. [DOI: 10.1016/j.foodcont.2014.11.045] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
22
|
Electrochemical genosensors as innovative tools for detection of genetically modified organisms. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2014.10.006] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
23
|
Feng J, Tang S, Liu L, Kuang X, Wang X, Hu S, You S. Development of a loop-mediated isothermal amplification (LAMP) assay for rapid and specific detection of common genetically modified organisms (GMOs). Int J Food Sci Nutr 2015; 66:186-96. [PMID: 25582179 DOI: 10.3109/09637486.2014.979318] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Here, we developed a loop-mediated isothermal amplification (LAMP) assay for 11 common transgenic target DNA in GMOs. Six sets of LAMP primer candidates for each target were designed and their specificity, sensitivity, and reproductivity were evaluated. With the optimized LAMP primers, this LAMP assay was simply run within 45-60 min to detect all these targets in GMOs tested. The sensitivity, specificity, and reproductivity of the LAMP assay were further analyzed in comparison with those of Real-Time PCR. In consistent with real-time PCR, detection of 0.5% GMOs in equivalent background DNA was possible using this LAMP assay for all targets. In comparison with real-time PCR, the LAMP assay showed the same results with simple instruments. Hence, the LAMP assay developed can provide a rapid and simple approach for routine screening as well as specific events detection of many GMOs.
Collapse
Affiliation(s)
- Jiawang Feng
- Zhuhai Entry-Exit Inspection and Quarantine Bureau , Zhuhai , P.R. China
| | | | | | | | | | | | | |
Collapse
|
24
|
Zhang X, Lowe SB, Gooding JJ. Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP). Biosens Bioelectron 2014; 61:491-9. [DOI: 10.1016/j.bios.2014.05.039] [Citation(s) in RCA: 194] [Impact Index Per Article: 19.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Revised: 05/14/2014] [Accepted: 05/15/2014] [Indexed: 01/20/2023]
|
25
|
|
26
|
Vaagt F, Haase I, Fischer M. Loop-mediated isothermal amplification (LAMP)-based method for rapid mushroom species identification. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2013; 61:1833-1840. [PMID: 23350919 DOI: 10.1021/jf304824b] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Toxic mushroom species, such as the death cap ( Amanita phalloides ), are responsible for most mushroom poisonings. In the present work, novel loop-mediated isothermal amplification (LAMP) assays were used for the differentiation of even closely related edible and toxic mushroom species. The applicability of these methods was tested by cross-reaction studies and analysis of spiked mushroom samples (raw and fried material). Contaminations at the level of 2% (w/w) could be detected in different mushroom blends. Three detection methods were used: agarose gel analysis, fluorimetric real-time detection, and visual detection by lateral flow dipsticks (LFD). The LAMP assay combined with LFD detection allows the identification of A. phalloides in about 2 h (including DNA extraction) at a very low level of technical equipment (micropestle, water bath, and mobile centrifuge), which makes this technique perfectly suited for on-site applications.
Collapse
Affiliation(s)
- Franziska Vaagt
- Hamburg School of Food Science, Institute of Food Chemistry, University of Hamburg, Hamburg, Germany
| | | | | |
Collapse
|