1
|
Giorgetti A, Bini C, Amurri S, Fazio G, Valentini L, Gobbi P, Pelotti S. Transfer and recovery of DNA and metal particles: A proof-of-concept application of a parallel strategy by DNA and environmental scanning electron microscopy analysis. Forensic Sci Int Genet 2024; 73:103113. [PMID: 39126795 DOI: 10.1016/j.fsigen.2024.103113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 06/18/2024] [Accepted: 07/30/2024] [Indexed: 08/12/2024]
Abstract
According to the principle of Locard "Every contact leaves a trace", when touching a surface, a bi-directional transfer of self and non-self-DNA residing on the hands and touched objects can occur. Metals are commonly encountered in forensic evidence and, during hand contact with these surfaces, a transfer of metal particles could occur together with the transfer of human DNA. This study proposes a proof-concept approach for the original detection of metal particles and touch DNA to track the activity performed by a donor and particularly to assess the metallic substrate touched before the contact with a subsequent surface. To this scope, a scenario of contact events was simulated by three volunteers, who participated in fingerprint deposition firstly on copper and then on plastic and glass surfaces. Twenty-four stubs were collected on the hands of volunteers and the secondary surfaces and then analyzed by environmental scanning electron microscopy (ESEM). DNA was quantified only from copper and plastic surfaces. Ten additional volunteers followed the same protocol of deposition on copper and then on plastic surfaces to evaluate DNA transfer only. On 20 touch DNA samples, the copper surface yielded significantly lower DNA amounts, ranging from 0.001 to 0.129 ng/μl, compared to the secondary touched plastic surface, ranging from 0.007 to 0.362 ng/μl. ESEM-EDS analysis showed that copper particles could be abundantly detected on the hands of the volunteers after contact with the copper surface. Particles containing silicates with copper were shown on plastic, while they were only found in 1/3 of samples on glass. Our proof-of-concept study has shown that ESEM-EDS analysis has the potential to detect copper particles transferred to the hands of volunteers during contact with a copper metallic surface and deposited on secondarily touched items. The results suggest that this original ESEM-DNA parallel approach could potentially allow the tracking of DNA transfer and metal particles at a crime scene, although this represents only a first step and further research on a wider casuistry could help to address the interpretation of results given activity level propositions.
Collapse
Affiliation(s)
- Arianna Giorgetti
- Department of Medical and Surgical Sciences, Unit of Legal Medicine, University of Bologna, Via Irnerio 49, Bologna 40126, Italy
| | - Carla Bini
- Department of Medical and Surgical Sciences, Unit of Legal Medicine, University of Bologna, Via Irnerio 49, Bologna 40126, Italy.
| | - Sara Amurri
- Department of Medical and Surgical Sciences, Unit of Legal Medicine, University of Bologna, Via Irnerio 49, Bologna 40126, Italy
| | - Giulia Fazio
- Department of Medical and Surgical Sciences, Unit of Legal Medicine, University of Bologna, Via Irnerio 49, Bologna 40126, Italy
| | - Laura Valentini
- Department of Biomolecular Sciences, University of Urbino, Carlo Bo, Italy
| | - Pietro Gobbi
- Department of Biomolecular Sciences, University of Urbino, Carlo Bo, Italy
| | - Susi Pelotti
- Department of Medical and Surgical Sciences, Unit of Legal Medicine, University of Bologna, Via Irnerio 49, Bologna 40126, Italy
| |
Collapse
|
2
|
Zacher M, van Oorschot RAH, Handt O, Goray M. Transfer and persistence of intruder DNA within an office after reuse by owner. Forensic Sci Int Genet 2024; 73:103130. [PMID: 39217962 DOI: 10.1016/j.fsigen.2024.103130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Revised: 08/26/2024] [Accepted: 08/27/2024] [Indexed: 09/04/2024]
Abstract
The heightened sensitivity of DNA typing techniques, paired with the extensive use of trace DNA in forensic investigations, has resulted in an increased need to understand how and when DNA is deposited on surfaces of interest. This study focussed on the transfer, persistence, and prevalence of trace DNA in a single occupation of an office space by an intruder, when all contacts made during occupation and for the two hours prior and post occupation were known. The extent to which DNA could be recovered from contacted/not contacted surfaces was investigated. This study investigates the impacts of these movements and use of an office space when the duration of occupancy, surface contact histories and shedder status of participants are known. Contacts were documented and surfaces in the office space were targeted for sampling. Categories were set for target sampling that included different types of contact. Direct and indirect DNA transfer was detected in 55 % and 6 % of samples, respectively. Contactless DNA transfer was detected in 0.5 % of samples. The owner was observed as the sole/major/majority contributor in 77 % of the samples and as minor contributor in 10 % of samples. The intruder was observed as the sole/major/majority contributor in 14 % of samples and as the minor contributor in 16 %. An increased number of contacts increased the relative DNA contribution of the individual making the contact, however, not all observed direct contacts resulted in detectable DNA transfer. The outcome of this study will aid in better sample targeting strategies and contribute to the pool of data assisting in the development of activity level assessments.
Collapse
Affiliation(s)
- Monique Zacher
- College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia
| | - Roland A H van Oorschot
- Office of the Chief Forensic Scientist, Victoria Police Forensic Services Department, Macleod, Victoria, Australia; School of Agriculture, Biomedicine and Environment, La Trobe University, Bundoora, Victoria, Australia
| | - Oliva Handt
- College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia; Forensic Science South Australia, Adelaide, South Australia, Australia
| | - Mariya Goray
- College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia.
| |
Collapse
|
3
|
Monkman H, van Oorschot RAH, Goray M. The role of cats in human DNA transfer. Forensic Sci Int Genet 2024; 74:103132. [PMID: 39243527 DOI: 10.1016/j.fsigen.2024.103132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Revised: 08/13/2024] [Accepted: 09/01/2024] [Indexed: 09/09/2024]
Abstract
Domestic animals, such as cats and dogs, are present in the majority of Australian households. Recently, questions regarding the possibility that domestic animals can serve as silent witnesses, from whom evidence can be collected, or act as vectors of contamination and transfer, have started to be raised. Yet, little is known regarding the transfer and prevalence of human DNA to and from cats. This study investigated if cats are reservoirs and vectors for human DNA transfer. Twenty cats from 15 households were sampled from 4 different areas (head (fur), back (fur), left (skin) and right (fur)) to obtain information on the background DNA that may be found on an animal. Further, transfer of human DNA to and from an animal, after a short patting contact, was tested. Human DNA was found to be prevalent on all cats. Of the areas sampled, most DNA was collected from the top of the fur from the back followed by the head and right/fur. No or very low quantities of human DNA was recovered from the left (skin) area. Most of the human DNA originated from the owners, but DNA from others was also often present (47 % of samples). Further, the transfer tests demonstrated that human DNA transferred readily to (detected in 45 % of samples) and from (detected in 80 % of samples) cats during patting. These results show that animals can act as reservoirs of human DNA and vectors for human DNA transfer that may need to be considered during evaluative DNA reporting. Furthermore, if an interaction between an animal and a perpetrator is suspected, consideration should be given to collecting DNA evidence from suspected contact areas on an animal.
Collapse
Affiliation(s)
- Heidi Monkman
- College of Science and Engineering, Flinders University, Bedford Park, South Australia, Australia.
| | - Roland A H van Oorschot
- Office of the Chief Forensic Scientist, Victoria Police Forensic Services Department, Macleod, Victoria, Australia; School of Agriculture, Biomedicine and Environment, La Trobe University, Bundoora, Victoria, Australia
| | - Mariya Goray
- College of Science and Engineering, Flinders University, Bedford Park, South Australia, Australia
| |
Collapse
|
4
|
Petcharoen P, Nolan M, Kirkbride KP, Linacre A. Shedding more light on shedders. Forensic Sci Int Genet 2024; 72:103065. [PMID: 38851033 DOI: 10.1016/j.fsigen.2024.103065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Revised: 04/15/2024] [Accepted: 05/26/2024] [Indexed: 06/10/2024]
Abstract
We report on testing 100 individuals for their shedder status with the aim of demonstrating whether the process of cell staining is reproducible when testing a large number of people. A previous report using the same method was based on 11 donors and indicated that there may be a continuum of shedder types within this small sample set. In this report we also expand the time points post-handwashing to 0, 15, 30, 60, and 180 min. Triplicate samples were collected from both the right and left thumbs. Samples were collected by donors placing a thumb on a clean glass slide and then adding a DNA binding dye. The number of cells were recorded within three separate square millimetre areas (cells/mm2) at 220x magnification. The experiments were conducted in triplicate on three different days, giving a total of 72 thumbprints per individual. Finally, there were 3438 observed frames in the entire dataset. Of the 100 donors, 98 gave consistent and reproducible cell number deposition. There was no difference between the cells deposited by the left and right thumbs in 13 of 15 tested. Males tended to deposit more cells than females. If applying arbitrary boundary to a cell count to definitively determine shedder status, then many of the donors fell within two categories. This study based on 100 individuals strongly suggests that shedder status is a continuum phenomenon.
Collapse
Affiliation(s)
- Piyamas Petcharoen
- School of Biology, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand
| | - Madison Nolan
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia
| | - K Paul Kirkbride
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia
| | - Adrian Linacre
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia.
| |
Collapse
|
5
|
Madden I, Taylor D, Mitchell N, Goray M, Henry J. Predicting probative levels of touch DNA on tapelifts using Diamond™ Nucleic Acid Dye. Forensic Sci Int Genet 2024; 70:103024. [PMID: 38335775 DOI: 10.1016/j.fsigen.2024.103024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 01/29/2024] [Accepted: 02/02/2024] [Indexed: 02/12/2024]
Abstract
Tapelifting is a common strategy to recover touch DNA deposits from porous exhibits in forensic DNA casework. However, it is known that only about 30 % of tapelifts submitted for DNA analysis in operational forensic laboratories yield profiles suitable for comparison or upload to a searchable database. A reliable means to identify and remove non-probative tapelifts from the workflow would reduce sample backlogs and provide significant cost savings. We investigated whether the amount of macroscopic or microscopic fluorescence on a tapelift following staining with Diamond Nucleic Acid Dye (DD), determined using a Polilight and Dino Lite microscope respectively, could predict the DNA yield and/or the DNA profiling outcome using controlled (saliva), semi-controlled (finger mark) and uncontrolled (clothing) samples. Both macroscopic and microscopic DD fluorescence could predict DNA yield and profiling outcome for all sample types, however the predictive power deteriorated as the samples became less controlled. For tapelifts of clothing, which are operationally relevant, Polilight fluorescence scores were significantly impacted by clothing fibres and other non-cellular debris and could not be used to identify non-probative samples. The presence of less than 500 cells on a clothing tapelift using microscopic counting of stained corneocytes was identified as a potential threshold for a non-probative DNA profiling outcome. A broader examination of the reliability of this threshold using a casework trial is recommended. Due to the labour intensiveness of microscopic cell counting, and the increased risk of inadvertent contamination, automation of this process using image software in conjunction with artificial neural networks (ANN) should be explored.
Collapse
Affiliation(s)
- Isla Madden
- College of Science and Engineering, Flinders University of South Australia, Bedford Park, South Australia 5042, Australia
| | - Duncan Taylor
- College of Science and Engineering, Flinders University of South Australia, Bedford Park, South Australia 5042, Australia; Forensic Science SA, GPO Box 2790, Adelaide, South Australia 5001, Australia
| | - Natasha Mitchell
- Forensic Science SA, GPO Box 2790, Adelaide, South Australia 5001, Australia
| | - Mariya Goray
- College of Science and Engineering, Flinders University of South Australia, Bedford Park, South Australia 5042, Australia
| | - Julianne Henry
- College of Science and Engineering, Flinders University of South Australia, Bedford Park, South Australia 5042, Australia; Forensic Science SA, GPO Box 2790, Adelaide, South Australia 5001, Australia.
| |
Collapse
|
6
|
Bathrick AS, Norsworthy S, Plaza DT, McCormick MN, Slack D, Ramotowski RS. DNA recovery after sequential processing of latent fingerprints on black polyethylene plastic. J Forensic Sci 2024; 69:993-1001. [PMID: 38402545 DOI: 10.1111/1556-4029.15498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 02/12/2024] [Accepted: 02/12/2024] [Indexed: 02/26/2024]
Abstract
Latent fingerprints on plastic substrates can be visualized by using sequential treatments to enhance the contrast between the fingerprint residues and underlying substrate; however, the extent to which these processes affect subsequent DNA analysis is mostly unknown. Latent fingerprints deposited on black plastic by one donor were visualized with single-process fingerprint powders (i.e., white powder, bichromatic powder, or bichromatic magnetic powder) or sequential treatments (i.e., laser → reflected ultraviolet imaging system (RUVIS) → CA fuming → RUVIS → Rhodamine 6G, Ardrox, and MBD (RAM) or CA fuming → RAM/laser → bichromatic magnetic powder). Samples were examined after the addition of each treatment. DNA was collected using cotton swabs, extracted, quantified, and amplified. DNA yields, peak heights, number of alleles obtained, and percentage of DNA profiles eligible for CODIS upload were examined. Latent fingerprints processed with the laser and up to three sequential treatments generated DNA profiles with significantly higher peaks heights than those of the untreated samples. Fingerprints processed with the laser and up to two sequential treatments generated DNA profiles with significantly more alleles. All methods beginning with laser enhancement generated more CODIS-eligible profiles. Additional research is needed to determine the extent to which initial laser enhancement impacts the success of downstream DNA profiling results. Although DNA profile development is not guaranteed due to the variable quantities of DNA contained within latent fingerprints, the selection of an appropriate latent fingerprint visualization method could maximize both fingerprint detection and the generation of CODIS-eligible DNA profiles.
Collapse
Affiliation(s)
| | - Sarah Norsworthy
- Forensic Technology Center of Excellence, RTI International, Research Triangle Park, North Carolina, USA
| | | | - Mallory N McCormick
- Forensic Services Division, United States Secret Service, Washington, DC, USA
| | - Donia Slack
- Forensic Technology Center of Excellence, RTI International, Research Triangle Park, North Carolina, USA
| | - Robert S Ramotowski
- Forensic Services Division, United States Secret Service, Washington, DC, USA
| |
Collapse
|
7
|
Fantinato C, Gill P, Fonneløp AE. Investigative use of human environmental DNA in forensic genetics. Forensic Sci Int Genet 2024; 70:103021. [PMID: 38335776 DOI: 10.1016/j.fsigen.2024.103021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 01/19/2024] [Accepted: 01/25/2024] [Indexed: 02/12/2024]
Abstract
Individuals leave behind traces of their DNA wherever they go. DNA can be transferred to surfaces and items upon touch, can be released into the air, and may be deposited in indoor dust. The mere presence of individuals in a location is sufficient to facilitate either direct or indirect DNA transfer into the surrounding environment. In this study, we analyzed samples recovered from commonly touched surfaces such as light switches and door handles in an office environment. We evaluated two different methods to isolate DNA and co-extract DNA and RNA from the samples. DNA profiles were compared to the references of the inhabitants of the different locations and were analyzed taking into consideration the type of sampled surface, sampling location and information about the activities in a room during the sampling day. Results from DNA samples collected from surfaces were also compared to those from air and dust samples collected in parallel from the same areas. We characterized the amount and composition of DNA found on various surfaces and showed that surface DNA sampling can be used to detect occupants of a location. The results also indicate that combining information from environmental samples collected from different DNA sources can improve our understanding of DNA transfer events in an indoor setting. This study further demonstrates the potential of human environmental DNA as an investigative tool in forensic genetics.
Collapse
Affiliation(s)
- Chiara Fantinato
- Forensic Genetics Research Group, Department of Forensic Sciences, Oslo University Hospital, Oslo, Norway; Department of Forensic Medicine, Institute of Clinical Medicine, University of Oslo, Oslo, Norway.
| | - Peter Gill
- Forensic Genetics Research Group, Department of Forensic Sciences, Oslo University Hospital, Oslo, Norway; Department of Forensic Medicine, Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| | - Ane Elida Fonneløp
- Forensic Genetics Research Group, Department of Forensic Sciences, Oslo University Hospital, Oslo, Norway; Centre for Ecological and Evolutionary Synthesis (CEES), Department of Biosciences, University of Oslo, Oslo, Norway
| |
Collapse
|
8
|
Henry L, Zieger M. Self- and non-self-DNA on hands and sleeve cuffs. Int J Legal Med 2024; 138:757-766. [PMID: 38053003 PMCID: PMC11004043 DOI: 10.1007/s00414-023-03124-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Accepted: 11/08/2023] [Indexed: 12/07/2023]
Abstract
Studying DNA transfer and persistence has become increasingly important over the last decade, due to the impressive sensitivity of modern DNA detection methods in forensic genetics. To improve our understanding of background DNA that could also potentially be transferred, we analyzed the DNA composition on the outside of sleeve cuffs and sampled DNA directly from the hands of four different collaborators upon their arrival at work during 25 working days. Sampling of their hands was repeated after several hours working in our department. The shedder status of the participants, as assumed from previous internal studies, was well re-produced in the study. However, we noticed that the DNA shedding capacity could also change drastically during the day, with one participant showing a more than sixfold increase between hands sampled in the morning and hands sampled in the afternoon. As expected, poor DNA shedders carry more relative amounts of non-self-DNA on their hands than good shedders. Non-self-alleles were detected in 95% of the samples. We also observed potential effects of hand washing and the mode of transport to get to work on the DNA amount. People living with family members occasionally carried their DNA on their hands and more frequently on their sleeve cuffs. Sleeve cuffs, as being close to our hands, have a large potential to transfer DNA from one place to another, yet they have sparsely been studied as DNA transfer intermediates so far. In general, we collected consistently more DNA from the sleeve cuffs than from the hands of the participants, demonstrating their importance as potential transfer vectors. More DNA was recovered from sleeve cuffs made of synthetic fabric than from cuffs made of cotton or leather. In the afternoon, DNA from co-habitant family members could not be detected on the hands anymore and the detection of profiles from colleagues became more frequent. From two out of 100 analyzed sleeve cuffs and two out of 200 sampled hands, we established unknown major DNA profiles that would have been suitable for an entry in the national DNA database. This finding demonstrates the possibility to transfer DNA that has most likely been picked up somewhere in the public space.
Collapse
Affiliation(s)
- Léonie Henry
- Institute of Forensic Medicine, Forensic Molecular Biology Department, University of Bern, Murtenstrasse 26, 3008, Bern, Switzerland
| | - Martin Zieger
- Institute of Forensic Medicine, Forensic Molecular Biology Department, University of Bern, Murtenstrasse 26, 3008, Bern, Switzerland.
| |
Collapse
|
9
|
Arsenault H, Kuffel A, Daeid NN, Gray A. Trace DNA and its persistence on various surfaces: A long term study investigating the influence of surface type and environmental conditions - Part one, metals. Forensic Sci Int Genet 2024; 70:103011. [PMID: 38324952 DOI: 10.1016/j.fsigen.2024.103011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 01/15/2024] [Accepted: 01/15/2024] [Indexed: 02/09/2024]
Abstract
It is imperative for proper evidence triage that forensic biologists understand what kind of results to expect from certain evidence types submitted for DNA analysis. The persistence of trace DNA has been insufficiently investigated and there is little data available pertaining to the persistence of DNA in different environmental conditions and on different materials. The goal of this study is to increase the available data on this topic which would, in turn, help forensic biologists manage expectations when submitting specific evidence types for DNA testing. The work presented herein is a large-scale persistence project aimed to identify trends in the persistence of trace DNA and indicate how different environmental storage conditions and target surface characteristics influence the persistence of cellular and cell free DNA (cfDNA) over time. To eliminate variation within the experiment we used a proxy DNA deposit consisting of a synthetic fingerprint solution, cellular DNA, and/or cfDNA. Samples were collected and analysed from 7 metals over the course of 1 year (27 time points) under 3 different environmental storage conditions. The results of this experiment show that metal type greatly influences DNA persistence. For instance, copper exhibited an expected poor DNA persistence (up to 4 h) which a purification step did not help increase the DNA yield. Alternatively, DNA can persist for up to a year on lead at levels potentially high enough to allow for forensic DNA testing. Additionally, this study showed that the sample storage environment had no impact on DNA persistence in most cases. When considering DNA type, cfDNA was shown to persist for longer than cellular DNA and persistence as a whole appears to be better when DNA is deposited as mixtures over when deposited alone. Unsurprisingly, it can be expected that DNA recovery rates from trace deposits will decrease over time. However, DNA decay is highly dependent on the metal surface and extremely variable at short time points but slightly less variable as time since deposition increases. This data is intended to add to our understanding of DNA persistence and the factors which affect it.
Collapse
Affiliation(s)
- Hilary Arsenault
- Leverhulme Research Center for Forensic Science, University of Dundee, Smalls Wynd, Dundee DD1 4HN, UK.
| | - Agnieszka Kuffel
- Leverhulme Research Center for Forensic Science, University of Dundee, Smalls Wynd, Dundee DD1 4HN, UK
| | - Niamh Nic Daeid
- Leverhulme Research Center for Forensic Science, University of Dundee, Smalls Wynd, Dundee DD1 4HN, UK
| | - Alexander Gray
- Leverhulme Research Center for Forensic Science, University of Dundee, Smalls Wynd, Dundee DD1 4HN, UK
| |
Collapse
|
10
|
Hughes DA, Szkuta B, van Oorschot RAH, Conlan XA. The impact of substrate characteristics on the collection and persistence of biological materials, and their implications for forensic casework. Forensic Sci Int 2024; 356:111951. [PMID: 38301431 DOI: 10.1016/j.forsciint.2024.111951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 01/14/2024] [Accepted: 01/25/2024] [Indexed: 02/03/2024]
Abstract
This study assessed the level of nucleic acid persistence on the substrate pre-, and post-swabbing, in order to assess whether biological materials (touch, saliva, semen, and blood) are collected differently depending on the substrate characteristics. A total of 48 samples per deposit and substrate variety (n = 384) were assessed by tracking the persistence of nucleic acid using Diamond™ Nucleic Acid Dye (DD) staining and Polilight photography. The number of DD nucleic acid fluorescent complexes formed post-staining were counted (fluorescent count) and in conjunction with the fluorescence signal intensity (DD nucleic acid complex accumulation) used to estimate the level of nucleic acid persistence on substrates. Touch deposits have shown to be the most persistent deposit with strong adhesion capabilities on both substrate verities. Saliva displayed a higher persistence than semen and/or blood. Semen displayed a high collection efficiency as well as a high fluorescence signal intensity. Blood displayed a low persistence on both substrates with a superior collection efficiency that may also indicate a higher probability to become dislodged from surfaces given a particular activity. Our research has shown that the persistence and recovery of biological deposits is not only measurable but more importantly, may have the potential to be estimated, as such, may build an understanding that can provide valuable guidance for collection efficiency evaluations, and the assessing of the probability of particular profiles, given alternate propositions of means of transfer occurring.
Collapse
Affiliation(s)
- Deborah A Hughes
- Deakin University, School of Life and Environmental Sciences, Geelong, Australia; Office of the Chief Forensic Scientist, Victoria Police Forensic Services Centre, Macleod, Australia
| | - Bianca Szkuta
- Deakin University, School of Life and Environmental Sciences, Geelong, Australia
| | - Roland A H van Oorschot
- Office of the Chief Forensic Scientist, Victoria Police Forensic Services Centre, Macleod, Australia; School of Agriculture, Biomedicine and Environment, La Trobe University, Bundoora, Australia
| | - Xavier A Conlan
- Deakin University, School of Life and Environmental Sciences, Geelong, Australia.
| |
Collapse
|
11
|
Jansson L, Siti C, Hedell R, Forsberg C, Ansell R, Hedman J. Assessing the consistency of shedder status under various experimental conditions. Forensic Sci Int Genet 2024; 69:103002. [PMID: 38176092 DOI: 10.1016/j.fsigen.2023.103002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 12/15/2023] [Accepted: 12/16/2023] [Indexed: 01/06/2024]
Abstract
Shedder status is defined as the propensity of an individual to leave DNA behind on touched items or surfaces and has been suggested as one of the major factors influencing DNA transfer. However, little is known about whether shedder status is a constant property of an individual across multiple measurements or when the environmental conditions are changed. We have assessed DNA depositions of six males on 20 occasions to acquire a reference data set and to classify the participants into high, intermediate, or low shedders. This data set was also used to investigate how the probability of a correct shedder status classification changed when the number of DNA deposition measurements increased. Individual sweat rates were measured with a VapoMeter and data regarding hygiene routines were collected through a questionnaire on each sampling occasion. Next, we investigated how changes in the experimental conditions such as seasonal variation, hygiene routines, the temperature of the touched object, and repeated handling of an object influenced the DNA shedding. Additionally, we assessed DNA collected from the face and from T-shirts worn by the six participants to explore whether shedder status may be associated with the relative amount of DNA obtained from other body parts. Our results indicate that shedder status is a stable property across different seasons and different temperatures of handled objects. The relative DNA amounts obtained from repeatedly handled tubes, worn T-shirts, and from faces reflected the shedder status of the participants. We suggest that an individual's shedder status is highly influenced by the DNA levels on other body parts than hands, accumulating on the palms by frequently touching e.g., the face or previously handled items harboring self-DNA. Assessing physiological differences between the participants revealed that there were no associations between DNA shedding and individual sweat rates.
Collapse
Affiliation(s)
- Linda Jansson
- National Forensic Centre, Swedish Police Authority, Linköping, Sweden; Applied Microbiology, Department of Chemistry, Lund University, Lund, Sweden
| | - Chiara Siti
- Applied Microbiology, Department of Chemistry, Lund University, Lund, Sweden
| | - Ronny Hedell
- National Forensic Centre, Swedish Police Authority, Linköping, Sweden
| | | | - Ricky Ansell
- National Forensic Centre, Swedish Police Authority, Linköping, Sweden; Department of Physics, Chemistry and Biology, IFM, Linköping University, Linköping, Sweden
| | - Johannes Hedman
- National Forensic Centre, Swedish Police Authority, Linköping, Sweden; Applied Microbiology, Department of Chemistry, Lund University, Lund, Sweden.
| |
Collapse
|
12
|
Onofri M, Tommolini F, Severini S, Gambelunghe C, Lancia M, Carlini L, Carnevali E. Trace DNA Transfer in Co-Working Spaces: The Importance of Background DNA Analysis. Int J Mol Sci 2024; 25:2207. [PMID: 38396883 PMCID: PMC10888653 DOI: 10.3390/ijms25042207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 02/08/2024] [Accepted: 02/09/2024] [Indexed: 02/25/2024] Open
Abstract
The presence of background DNA (bgDNA) can hinder the evaluation of DNA evidence at the activity level, especially when the suspect is expected to be retrieved due to their habitual occupation of the investigated environment. Based on real-life casework circumstances, this study investigates the prevalence, composition, origin, and probable transfer routes of bgDNA found on personal items in situations where their owner and person of interest (POI) share the same workspace. Baseline values of bgDNA were evaluated on the participants' personal items. Secondary and higher degree transfer scenarios of non-self DNA deposition were also investigated. The DNA from co-workers and co-inhabiting partners can be recovered from an individual's personal belongings. Non-self DNA present on the hands and deposited on a sterile surface can generate uninformative profiles. The accumulation of foreign DNA on surfaces over time appears to be crucial for the recovery of comparable profiles, resulting in detectable further transfer onto other surfaces. For a thorough evaluation of touch DNA traces at the activity level, it is necessary to collect information not only about DNA transfer probabilities but also about the presence of the POI as part of the 'baseline' bgDNA of the substrates involved.
Collapse
Affiliation(s)
- Martina Onofri
- Forensic Sciences Laboratory, Section of Legal Medicine, Department of Medicine and Surgery, Santa Maria Hospital, University of Perugia, 05100 Terni, Italy; (F.T.); (S.S.); (E.C.)
- Section of Legal Medicine, Department of Medicine and Surgery, University of Perugia, 06123 Perugia, Italy; (C.G.); (M.L.); (L.C.)
| | - Federica Tommolini
- Forensic Sciences Laboratory, Section of Legal Medicine, Department of Medicine and Surgery, Santa Maria Hospital, University of Perugia, 05100 Terni, Italy; (F.T.); (S.S.); (E.C.)
| | - Simona Severini
- Forensic Sciences Laboratory, Section of Legal Medicine, Department of Medicine and Surgery, Santa Maria Hospital, University of Perugia, 05100 Terni, Italy; (F.T.); (S.S.); (E.C.)
| | - Cristiana Gambelunghe
- Section of Legal Medicine, Department of Medicine and Surgery, University of Perugia, 06123 Perugia, Italy; (C.G.); (M.L.); (L.C.)
| | - Massimo Lancia
- Section of Legal Medicine, Department of Medicine and Surgery, University of Perugia, 06123 Perugia, Italy; (C.G.); (M.L.); (L.C.)
| | - Luigi Carlini
- Section of Legal Medicine, Department of Medicine and Surgery, University of Perugia, 06123 Perugia, Italy; (C.G.); (M.L.); (L.C.)
| | - Eugenia Carnevali
- Forensic Sciences Laboratory, Section of Legal Medicine, Department of Medicine and Surgery, Santa Maria Hospital, University of Perugia, 05100 Terni, Italy; (F.T.); (S.S.); (E.C.)
| |
Collapse
|
13
|
Fantinato C, Fonneløp AE, Bleka Ø, Vigeland MD, Gill P. The invisible witness: air and dust as DNA evidence of human occupancy in indoor premises. Sci Rep 2023; 13:19059. [PMID: 37925517 PMCID: PMC10625553 DOI: 10.1038/s41598-023-46151-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 10/28/2023] [Indexed: 11/06/2023] Open
Abstract
Humans constantly shed deoxyribonucleic acid (DNA) into the surrounding environment. This DNA may either remain suspended in the air or it settles onto surfaces as indoor dust. In this study, we explored the potential use of human DNA recovered from air and dust to investigate crimes where there are no visible traces available-for example, from a recently vacated drugs factory where multiple workers had been present. Samples were collected from three indoor locations (offices, meeting rooms and laboratories) characterized by different occupancy types and cleaning regimes. The resultant DNA profiles were compared with the reference profiles of 55 occupants of the premises. Our findings showed that indoor dust samples are rich sources of DNA and provide an historical record of occupants within the specific locality of collection. Detectable levels of DNA were also observed in air and dust samples from ultra-clean forensic laboratories which can potentially contaminate casework samples. We provide a Bayesian statistical model to estimate the minimum number of dust samples needed to detect all inhabitants of a location. The results of this study suggest that air and dust could become novel sources of DNA evidence to identify current and past occupants of a crime scene.
Collapse
Affiliation(s)
- Chiara Fantinato
- Department of Forensic Sciences, Oslo University Hospital, Oslo, Norway.
- Department of Forensic Medicine, Institute of Clinical Medicine, University of Oslo, Oslo, Norway.
| | - Ane Elida Fonneløp
- Department of Forensic Sciences, Oslo University Hospital, Oslo, Norway
- Centre for Ecological and Evolutionary Synthesis (CEES), Department of Biosciences, University of Oslo, Oslo, Norway
| | - Øyvind Bleka
- Department of Forensic Sciences, Oslo University Hospital, Oslo, Norway
| | | | - Peter Gill
- Department of Forensic Sciences, Oslo University Hospital, Oslo, Norway
- Department of Forensic Medicine, Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| |
Collapse
|
14
|
Nolan M, Handt O, Linacre A. Persistence of cellular material after exposure to water. J Forensic Sci 2023; 68:2128-2137. [PMID: 37356058 DOI: 10.1111/1556-4029.15316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 06/08/2023] [Accepted: 06/12/2023] [Indexed: 06/27/2023]
Abstract
Disposing of items of forensic relevance in bodies of water is one countermeasure offenders can use to avoid detection. The impact of immersion in water has been explored for blood, saliva, and semen; however, few studies have assessed touch DNA. Here we report on the effect of exposure to water on the persistence of touch DNA over prolonged periods of time. To evaluate the persistence of cells from touch DNA, after water exposure, three substrates and two water types were tested: plastic, metal, and ceramic, submerged into seawater or tap water. Diamond™ Nucleic Acid Dye was used to stain cells deposited by touch. Cell counts before and after water exposure were compared to investigate cell loss over time, ranging from 6 hours to 5 days. A logarithmic increase in the percent of cells lost was observed over time when the data for substrate and water type conditions were combined. Substrate type influenced the persistence of cells, with the metal substrate retaining cells longer than plastic or ceramic. The influence of water type appeared dependent on the substrate, with varied cell persistence on metal whereas plastic and ceramic recorded similar cell loss over time between water types. The ability to visualize cells after exposure to water could assist in triaging evidence within operational forensic laboratories and allow for targeted sampling. This proof-of-concept study demonstrated that greater than 50% of cells can persist on various items submerged in aqueous environments for at least 5 days, highlighting the possibility for downstream DNA testing.
Collapse
Affiliation(s)
- Madison Nolan
- College of Science and Engineering, Flinders University, Adelaide, Australia
| | - Oliva Handt
- College of Science and Engineering, Flinders University, Adelaide, Australia
- Forensic Science South Australia, Adelaide, Australia
| | - Adrian Linacre
- College of Science and Engineering, Flinders University, Adelaide, Australia
| |
Collapse
|
15
|
Recipon M, Agniel R, Leroy-Dudal J, Fritz T, Carreiras F, Hermitte F, Hubac S, Gallet O, Kellouche S. Targeting cell-derived markers to improve the detection of invisible biological traces for the purpose of genetic-based criminal identification. Sci Rep 2023; 13:18105. [PMID: 37872292 PMCID: PMC10593828 DOI: 10.1038/s41598-023-45366-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 10/18/2023] [Indexed: 10/25/2023] Open
Abstract
At a crime scene, investigators are faced with a multitude of traces. Among them, biological traces are of primary interest for the rapid genetic-based identification of individuals. "Touch DNA" consists of invisible biological traces left by the simple contact of a person's skin with objects. To date, these traces remain undetectable with the current methods available in the field. This study proposes a proof-of-concept for the original detection of touch DNA by targeting cell-derived fragments in addition to DNA. More specifically, adhesive-structure proteins (laminin, keratin) as well as carbohydrate patterns (mannose, galactose) have been detected with keratinocyte cells derived from a skin and fingermark touch-DNA model over two months in outdoor conditions. Better still, this combinatory detection strategy is compatible with DNA profiling. This proof-of-concept work paves the way for the optimization of tools that can detect touch DNA, which remains a real challenge in helping investigators and the delivery of justice.
Collapse
Affiliation(s)
- Mathilde Recipon
- Equipe de Recherche sur les Relations Matrice Extracellulaire-Cellules, ERRMECe, (EA1391), Groupe Matrice Extracellulaire et Physiopathologie (MECuP), Institut des Matériaux, I-MAT (FD4122), CY Cergy Paris Université, Neuville sur Oise, France.
- Institut de Recherche Criminelle de la Gendarmerie Nationale, Cergy-Pontoise, France.
| | - Rémy Agniel
- Equipe de Recherche sur les Relations Matrice Extracellulaire-Cellules, ERRMECe, (EA1391), Groupe Matrice Extracellulaire et Physiopathologie (MECuP), Institut des Matériaux, I-MAT (FD4122), CY Cergy Paris Université, Neuville sur Oise, France
| | - Johanne Leroy-Dudal
- Equipe de Recherche sur les Relations Matrice Extracellulaire-Cellules, ERRMECe, (EA1391), Groupe Matrice Extracellulaire et Physiopathologie (MECuP), Institut des Matériaux, I-MAT (FD4122), CY Cergy Paris Université, Neuville sur Oise, France
| | - Thibaud Fritz
- Institut de Recherche Criminelle de la Gendarmerie Nationale, Cergy-Pontoise, France
| | - Franck Carreiras
- Equipe de Recherche sur les Relations Matrice Extracellulaire-Cellules, ERRMECe, (EA1391), Groupe Matrice Extracellulaire et Physiopathologie (MECuP), Institut des Matériaux, I-MAT (FD4122), CY Cergy Paris Université, Neuville sur Oise, France
| | - Francis Hermitte
- Institut de Recherche Criminelle de la Gendarmerie Nationale, Cergy-Pontoise, France
| | - Sylvain Hubac
- Institut de Recherche Criminelle de la Gendarmerie Nationale, Cergy-Pontoise, France
| | - Olivier Gallet
- Equipe de Recherche sur les Relations Matrice Extracellulaire-Cellules, ERRMECe, (EA1391), Groupe Matrice Extracellulaire et Physiopathologie (MECuP), Institut des Matériaux, I-MAT (FD4122), CY Cergy Paris Université, Neuville sur Oise, France
| | - Sabrina Kellouche
- Equipe de Recherche sur les Relations Matrice Extracellulaire-Cellules, ERRMECe, (EA1391), Groupe Matrice Extracellulaire et Physiopathologie (MECuP), Institut des Matériaux, I-MAT (FD4122), CY Cergy Paris Université, Neuville sur Oise, France
| |
Collapse
|
16
|
Monkman H, Szkuta B, van Oorschot RAH. Presence of Human DNA on Household Dogs and Its Bi-Directional Transfer. Genes (Basel) 2023; 14:1486. [PMID: 37510390 PMCID: PMC10379355 DOI: 10.3390/genes14071486] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 07/11/2023] [Accepted: 07/19/2023] [Indexed: 07/30/2023] Open
Abstract
Awareness of the factors surrounding the transfer of DNA from a person, item, or surface to another person, item, or surface is highly relevant during investigations of alleged criminal activity. Animals in domestic environments could be a victim, offender, or innocent party associated with a crime. There is, however, very limited knowledge of human DNA transfer, persistence, prevalence, and recovery (DNA TPPR) associated with domestic animals. This pilot study aimed to improve our understanding of DNA TPPR associated with domestic dogs by collecting and analysing samples from various external areas of dogs of various breeds, interactions with humans, and living arrangements, and conducting a series of tests to investigate the possibility of dogs being vectors for the indirect transfer of human DNA. Reference DNA profiles from the dog owners and others living in the same residence were acquired to assist interpretation of the findings. The findings show that human DNA is prevalent on dogs, and in the majority of samples, two-person mixtures are present. Dogs were also found to be vectors for the transfer of human DNA, with DNA transferred from the dog to a gloved hand during patting and a sheet while walking.
Collapse
Affiliation(s)
- Heidi Monkman
- School of Life and Environmental Sciences, Deakin University, Geelong 3220, Australia
- College of Science and Engineering, Flinders University, Bedford Park 5042, Australia
| | - Bianca Szkuta
- School of Life and Environmental Sciences, Deakin University, Geelong 3220, Australia
| | - Roland A H van Oorschot
- Office of the Chief Forensic Scientist, Victoria Police Forensic Services Department, Macleod 3085, Australia
- School of Agriculture, Biomedicine and Environment, La Trobe University, Bundoora 3086, Australia
| |
Collapse
|
17
|
Arsenault H, Nic Daeid N, Gray A. A synthetic fingerprint solution and its importance in DNA transfer, persistence and recovery studies. Forensic Sci Int Synerg 2023; 6:100330. [PMID: 37249970 PMCID: PMC10209804 DOI: 10.1016/j.fsisyn.2023.100330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 04/20/2023] [Accepted: 05/02/2023] [Indexed: 05/31/2023]
Abstract
A review of the literature on DNA transfer and persistence highlights many difficulties that are encountered when conducting research of this nature. One of the main problems highlighted repeatedly in the literature is the prevalence of inherent uncontrolled variation that accompany these studies, and in turn, the results obtained. This work aims to decrease the amount of intrinsic variability associated with DNA transfer and persistence experiments using a realistic proxy solution which is adaptable, of known composition, reproducible, and capable of being standardised. This proxy is composed of three parts: a synthetic fingerprint solution, cellular DNA, and cell free DNA. In this proof-of-concept study the proxy was tested with a small-scale DNA transfer and recovery experiment and the data obtained suggests that the use of a solution that mimics real fingerprint secretions, over an alternative (such as buffer or a body fluid), is important when working with non-donor provided trace DNA samples. This is because the DNA deposit solution likely impacts the transfer of DNA from fingers/hands to a surface as well as the ability to recover the biological material once deposited.
Collapse
|
18
|
Kaesler T, Kirkbride KP, Linacre A. Persistence of touch DNA on commonly encountered substrates in different storage conditions. Forensic Sci Int 2023; 348:111728. [PMID: 37209547 DOI: 10.1016/j.forsciint.2023.111728] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 03/29/2023] [Accepted: 05/08/2023] [Indexed: 05/22/2023]
Abstract
The persistence of touch DNA deposited after realistic handling of items typically encountered in forensic investigations has been the subject of few studies. Understanding the long-term persistence of touch DNA on different substrates in varying conditions can be central to the effective triage of samples for further processing. As the time between an alleged incident and collection of evidence may vary from a few days to years after an alleged event, this study assessed three different common substrates for the persistence of touch DNA over a time span up to 9 months. These substrates included fabric, steel, and rubber, each of which were handled in a way to imitate what may happen during a criminal act. The three substrates were exposed to two different environments for up to 9 months: inside a dark cupboard with no traffic to act as a control and an outside semi-exposed environment. Ten replicates from each of the 3 substrates were tested at 5 time points to create 300 samples. All samples were processed using a standard operating workflow to provide genotype data after exposure to different environments. It was found that the fabric samples produced informative STR profiles (defined here as 12 or more alleles) up to the 9 month timepoint for either environment. The rubber and steel substrates for the inside condition produced informative STR profiles up to the 9 month timepoint, but only generated informative STR profiles for the outside condition up to 3 and 6 months, respectively. These data add to our understanding of the external factors that affect DNA persistence.
Collapse
Affiliation(s)
- Todd Kaesler
- College of Science & Engineering, Flinders University, Adelaide 5042, South Australia.
| | - K Paul Kirkbride
- College of Science & Engineering, Flinders University, Adelaide 5042, South Australia
| | - Adrian Linacre
- College of Science & Engineering, Flinders University, Adelaide 5042, South Australia
| |
Collapse
|
19
|
Reither JB, van Oorschot RAH, Durdle A, Szkuta B. DNA transfer to placed, stored, and handled drug packaging and knives in houses. Forensic Sci Int Genet 2023; 65:102888. [PMID: 37182457 DOI: 10.1016/j.fsigen.2023.102888] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 05/04/2023] [Accepted: 05/07/2023] [Indexed: 05/16/2023]
Abstract
Forensic laboratories often sample weapons and clip-seal plastic bags (CSPB) used to package illicit material for the purpose of identifying the handler(s). However, there may be other explanations as to how a person's DNA was transferred to such items. This may include an individual storing the item among their personal belongings for somebody else or the item being stored among their belongings without their knowledge. Here we investigate the direct transfer of DNA to knives and CSPB during handling and explore two feasible alternative explanations related to the indirect transfer of DNA to these items in residential environments. The handling of DNA-free items was performed by 10 individuals who were instructed, on separate occasions, to cut a foam board in half and fill a CSPB with a drug substitute. To explore indirect transfer, sets of these items were (a) placed on kitchen benches and coffee/dining tables for ∼1 min, or (b) stored for two days in kitchen and bedroom drawers within the homes of 10 individuals. After each of the three scenarios, samples were collected from the knife handle and blade, the body and seal of the CSPB, and the surface the items were placed on, the latter as a measure to gain insight into the presence of prevalent and/or background DNA. DNA transfer was observed under all three scenarios, though more frequently when items were handled or stored for 2 days, compared to when placed on a surface for ∼1 min. Under the latter scenario, DNA, if present, was below the level of detection in many samples and produced no profile, suggesting that detectable DNA transfer occurs to a lesser degree from static brief contacts. The study results and associated probabilities will assist forensic examiners with their interpretation of case circumstances regarding the transfer and recovery of DNA from these items.
Collapse
Affiliation(s)
- Jack B Reither
- School of Life and Environmental Sciences, Deakin University, Geelong, VIC 3220, Australia; Office of the Chief Forensic Scientist, Victoria Police Forensic Services Department, Macleod, VIC 3085, Australia.
| | - Roland A H van Oorschot
- Office of the Chief Forensic Scientist, Victoria Police Forensic Services Department, Macleod, VIC 3085, Australia; School of Agriculture, Biomedicine and Environment, La Trobe University, Bundoora, VIC 3086, Australia
| | - Annalisa Durdle
- School of Life and Environmental Sciences, Deakin University, Geelong, VIC 3220, Australia
| | - Bianca Szkuta
- School of Life and Environmental Sciences, Deakin University, Geelong, VIC 3220, Australia
| |
Collapse
|
20
|
Onofri M, Altomare C, Severini S, Tommolini F, Lancia M, Carlini L, Gambelunghe C, Carnevali E. Direct and Secondary Transfer of Touch DNA on a Credit Card: Evidence Evaluation Given Activity Level Propositions and Application of Bayesian Networks. Genes (Basel) 2023; 14:genes14050996. [PMID: 37239356 DOI: 10.3390/genes14050996] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 04/24/2023] [Accepted: 04/26/2023] [Indexed: 05/28/2023] Open
Abstract
In a judiciary setting, questions regarding the mechanisms of transfer, persistence, and recovery of DNA are increasingly more common. The forensic expert is now asked to evaluate the strength of DNA trace evidence at activity level, thus assessing if a trace, given its qualitative and quantitative features, could be the result of an alleged activity. The present study is the reproduction of a real-life casework scenario of illicit credit card use by a co-worker (POI) of its owner (O). After assessing the shedding propensity of the participants, differences in DNA traces' qualitative and quantitative characteristics, given scenarios of primary and secondary transfer of touch DNA on a credit card, a non-porous plastic support, were investigated. A case-specific Bayesian Network to aid statistical evaluation was created and discrete observations, meaning the presence/absence of POI as a major contributor in both traces from direct and secondary transfer, were used to inform the probabilities of disputed activity events. Likelihood Ratios at activity level (LRα) were calculated for each possible outcome resulting from the DNA analysis. In instances where only POI and POI plus an unknown individual are retrieved, the values obtained show moderate to low support in favour of the prosecution proposition.
Collapse
Affiliation(s)
- Martina Onofri
- Section of Legal Medicine, Department of Medicine and Surgery, University of Perugia, 06123 Perugia, Italy
| | - Cristina Altomare
- Section of Legal Medicine, Department of Medicine and Surgery, University of Perugia, 06123 Perugia, Italy
| | - Simona Severini
- Section of Legal Medicine, Department of Medicine and Surgery, Santa Maria Hospital, University of Perugia, 05100 Terni, Italy
| | - Federica Tommolini
- Section of Legal Medicine, Department of Medicine and Surgery, Santa Maria Hospital, University of Perugia, 05100 Terni, Italy
| | - Massimo Lancia
- Section of Legal Medicine, Department of Medicine and Surgery, University of Perugia, 06123 Perugia, Italy
| | - Luigi Carlini
- Section of Legal Medicine, Department of Medicine and Surgery, University of Perugia, 06123 Perugia, Italy
| | - Cristiana Gambelunghe
- Section of Legal Medicine, Department of Medicine and Surgery, University of Perugia, 06123 Perugia, Italy
| | - Eugenia Carnevali
- Section of Legal Medicine, Department of Medicine and Surgery, Santa Maria Hospital, University of Perugia, 05100 Terni, Italy
| |
Collapse
|
21
|
Kaesler T, Kirkbride KP, Linacre A. Improvements, factors, and influences on DNA recovery from firearms. Forensic Sci Int Genet 2023; 65:102873. [PMID: 37094516 DOI: 10.1016/j.fsigen.2023.102873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 01/31/2023] [Accepted: 04/13/2023] [Indexed: 04/26/2023]
Abstract
Touch DNA recovery from firearms can be central to many criminal investigations, yet the generation of DNA profiles from these items remains poor. Currently in Australia, published casework data highlights extremely poor DNA success from samples recovered from firearms. Only between 5% and 25% of samples result in useful DNA data and therefore increasing the success of DNA recovered from firearms is highly important but has not yet been explored in-depth. This study focused on increasing the recovery of DNA from ten firearm components that were held for 15 s. Multiple recovery methods were used, and the resulting genetic data compared. DNA evidence may be deliberately removed from firearms after discharge to hamper forensic investigations, therefore this study examined the effect of wiping down the components or handling them with gloves. A standard double swab and rinse swab recovery method resulted in an average of 73% cellular recovery. A cumulative swab process had the highest average recovery at 86%, although it was found that increasing the DNA yield led to an increase in mixture complexity. Wiping over the components was observed to remove on average 69% of cellular material, compared with 33% when handed with gloves. However, the size and texture of the components affected the efficiency of cellular material removal. The results from this study allow for prioritisation of areas to sample on firearms, as well as suggesting techniques that can be applied for the optimum process of cellular recovery and subsequent generation of STR DNA data.
Collapse
Affiliation(s)
- Todd Kaesler
- College of Science & Engineering, Flinders University, Adelaide 5042, South Australia, Australia.
| | - K Paul Kirkbride
- College of Science & Engineering, Flinders University, Adelaide 5042, South Australia, Australia
| | - Adrian Linacre
- College of Science & Engineering, Flinders University, Adelaide 5042, South Australia, Australia
| |
Collapse
|
22
|
Gołaszewska A. Recovery techniques for contact DNA traces. ARCHIVES OF FORENSIC MEDICINE AND CRIMINOLOGY 2023. [DOI: 10.4467/16891716amsik.22.016.17394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2023] Open
Abstract
Donor DNA profiling can serve at least two purposes: 1) to enhance the evidential value of DNA deposited on garments/ items and 2) to provide valuable tactical information during crime scene investigation. In this review, different types of methods for the recovery of the contact DNA traces have been summarized. Additionally, with the available techniques, the unique characteristics and limitations thereof have been overviewed. The aim of this paper is to review the techniques of touch traces collection.
Techniki odzyskiwania śladów kontaktowych DNA
Profilowanie DNA dawcy może służyć co najmniej dwóm celom: 1) zwiększeniu wartości dowodowej DNA zdeponowanego na odzieży/przedmiotach oraz 2) dostarczeniu cennych informacji taktycznych podczas badania miejsca przestępstwa. W niniejszym przeglądzie podsumowano różne rodzaje metod odzyskiwania śladów kontaktowych DNA. Dodatkowo, w odniesieniu do dostępnych technik, dokonano przeglądu ich unikalnych cech i ograniczeń. Celem niniejszej pracy jest przegląd technik pozyskiwania śladów dotykowych.
Collapse
|
23
|
Kwok R, Parsons R, Fieldhouse S, Walton-Williams L. An evaluation of two adhesive media for the recovery of DNA from latent fingermarks: A preliminary study. Forensic Sci Int 2023; 344:111574. [PMID: 36739851 DOI: 10.1016/j.forsciint.2023.111574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 01/11/2023] [Accepted: 01/25/2023] [Indexed: 01/26/2023]
Abstract
Dual recovery of forensic evidence is beneficial for crime scene and evidence processing as it can potentially double the evidential value of a single source, even more so in instances of DNA fingermarks. The use of adhesive liftering media has shown comparable results to swabbing when dealing with trace DNA recovery. Gelatine lifters have displayed the potential to recover DNA from latent fingermarks with minimal alteration to friction ridge detail post application, yet their ability to recover DNA has not fully been explored. The aim of this research was to compare the use of gelatine lifters with more readily available masking tape in their ability to recover cellular material from latent fingermarks. Natural (n = 120) and sebaceous (n = 120) fingermarks were deposited and aged in time frames from fresh, 1-day, 2-day, 1-week, 2-weeks, and 1 month. DiamondTM Nucleic Acid Dye was used as a visualisation method for any DNA containing cellular material. Images of the fingermarks pre and post lifting, and on the lifting media were imaged using the DSC®5 system. The media's ability to recover cellular material was assessed using fluorescent particle analysis by the employment of the free software ImageJ. Fluorescent particles could be observed on the lifting media post lifting with the use of DiamondTM Dye. Time was not seen to influence the variation in the number of fluorescent particles observed. The use of gelatine lifters was found to have a higher amount of recovered DNA containing cellular material than masking tape. Visualisation of particles on masking tape were inhibited by its porosity and absorption of the dye. Some fingermark detail could be observed in the gelatine lifters. The DSC®5 system was suitable for imaging fingermarks stained with DiamondTM Dye.
Collapse
Affiliation(s)
- Ross Kwok
- School of Justice, Security and Sustainability, Staffordshire University, ST42DF, UK.
| | - Robin Parsons
- School of Justice, Security and Sustainability, Staffordshire University, ST42DF, UK.
| | - Sarah Fieldhouse
- School of Justice, Security and Sustainability, Staffordshire University, ST42DF, UK.
| | - Laura Walton-Williams
- School of Justice, Security and Sustainability, Staffordshire University, ST42DF, UK.
| |
Collapse
|
24
|
Linacre A, Petcharoen P. Detection of Latent DNA Using a DNA Binding Dye. Methods Mol Biol 2023; 2685:359-366. [PMID: 37439993 DOI: 10.1007/978-1-0716-3295-6_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/14/2023]
Abstract
Latent DNA can be deposited every time a person holds or touches an item. This "touch DNA" can be crucial evidence if the item is of forensic significance. Until very recently, there were no means to visualize this DNA. The advent of using a dye that binds to DNA has opened up this possibility. The application of the dye is simple to perform, and a mobile microscope allows rapid visualization of the cellular material, even in ambient light. The dye can be applied in a solution of either 75% ethanol or water. As this is a solution-based dye, the application works best on non-absorbent surfaces.DNA within cellular material, such as dead skin cells, appears as green dots under 50X magnification; zooming to 220X magnification confirms that these are cells. The location and number of these cells can be photographed allowing a record of the presence of otherwise latent DNA.This chapter details the processes involved in the detection of latent DNA using Diamond™ Nucleic Acid Dye with both control samples (that act as very effective training samples) and the staining of evidential items. By developing skills in determining cell locations, a targeted approach to crime scene collection is now possible.
Collapse
Affiliation(s)
- Adrian Linacre
- Forensic DNA Technology, College of Science and Engineering, Flinders University, Adelaide, SA, Australia.
| | - Piyamas Petcharoen
- Forensic Technology and Innovation Module, School of Biology, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima, Thailand
| |
Collapse
|
25
|
Tozzo P, Mazzobel E, Marcante B, Delicati A, Caenazzo L. Touch DNA Sampling Methods: Efficacy Evaluation and Systematic Review. Int J Mol Sci 2022; 23:15541. [PMID: 36555182 PMCID: PMC9779423 DOI: 10.3390/ijms232415541] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 12/01/2022] [Accepted: 12/06/2022] [Indexed: 12/13/2022] Open
Abstract
Collection and interpretation of "touch DNA" from crime scenes represent crucial steps during criminal investigations, with clear consequences in courtrooms. Although the main aspects of this type of evidence have been extensively studied, some controversial issues remain. For instance, there is no conclusive evidence indicating which sampling method results in the highest rate of biological material recovery. Thus, this study aimed to describe the actual considerations on touch DNA and to compare three different sampling procedures, which were "single-swab", "double-swab", and "other methods" (i.e., cutting out, adhesive tape, FTA® paper scraping), based on the experimental results published in the recent literature. The data analysis performed shows the higher efficiency of the single-swab method in DNA recovery in a wide variety of experimental settings. On the contrary, the double-swab technique and other methods do not seem to improve recovery rates. Despite the apparent discrepancy with previous research, these results underline certain limitations inherent to the sampling procedures investigated. The application of this information to forensic investigations and laboratories could improve operative standard procedures and enhance this almost fundamental investigative tool's probative value.
Collapse
Affiliation(s)
- Pamela Tozzo
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, Legal Medicine Section, University of Padova, 35121 Padova, Italy
| | | | | | | | | |
Collapse
|
26
|
Genetic profiling from 9 mm fired cartridge cases over 30 days. FORENSIC SCIENCE INTERNATIONAL GENETICS SUPPLEMENT SERIES 2022. [DOI: 10.1016/j.fsigss.2022.10.067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
27
|
Petcharoen P, Kirkbride KP, Linacre A. Monitoring cell loss through repetitive deposition. J Forensic Sci 2022; 67:2453-2457. [DOI: 10.1111/1556-4029.15140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 09/05/2022] [Accepted: 09/08/2022] [Indexed: 11/28/2022]
Affiliation(s)
- Piyamas Petcharoen
- School of Biology, Institute of Science Suranaree University of Technology Nakhon Ratchasima Thailand
- College of Science & Engineering Flinders University Adelaide South Australia Australia
| | | | - Adrian Linacre
- College of Science & Engineering Flinders University Adelaide South Australia Australia
| |
Collapse
|
28
|
Griffin A, Kirkbride KP, Henry J, Painter B, Linacre A. Recovery of integrated and surface trace DNA from illicit drug tablets. Forensic Sci Int Genet 2022; 61:102772. [PMID: 36099863 DOI: 10.1016/j.fsigen.2022.102772] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 08/11/2022] [Accepted: 09/06/2022] [Indexed: 11/04/2022]
Abstract
In many parts of the world, tablets are a commonly encountered form of illicit drug preparation. Whilst previous research has investigated the feasibility of detecting trace DNA on illicit drug capsules, this has not been performed for tablets. Tablets have a unique substrate surface and therefore the amount of DNA transferring to them and persisting on them may be different to capsules; there may also be differences in the collection efficiency and the outcome of downstream DNA processing and analysis steps. The ability to profile the DNA from individuals who handled tablets during their preparation and distribution would add another level of discrimination between various drug seizures or corroborate chemical profiling outcomes which may link various seizures to a common origin. DNA from two different individuals (male and female) was added to the tablets in two stages. Firstly, tablet powder was spiked with DNA from one individual to mimic the situation where DNA traces are incorporated during the drug synthesis or final drying stages. The powder was then pressed into tablets in a clean environment without intentional addition of DNA. Subsequently, a second individual counted out the tablets into bags of ten to mimic the preparation for distribution at a user level. The exterior of the tablet was swabbed and then the entire tablet and the swab were put through separate DNA extractions, yielding two DNA extracts for each tablet. Swabs of the exterior tablet surface yielded single source DNA profiles that identified the tablet handler in 100 % of samples. The tablet extract yielded the donor of the DNA intentionally added within the drug powder in 80% of samples with varying levels of support, however contributions of the exterior handler were detected in 60 % of samples. The identification of individuals potentially involved in the synthesis of the drugs compared to the distribution of the tablets will provide invaluable strategic intelligence related to illicit drug investigations and to law enforcement agencies.
Collapse
Affiliation(s)
- Amy Griffin
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia.
| | - K Paul Kirkbride
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia
| | - Julianne Henry
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia; Forensic Science SA, GPO Box 2790, Adelaide 5000, Australia
| | - Ben Painter
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia; Forensic Science SA, GPO Box 2790, Adelaide 5000, Australia
| | - Adrian Linacre
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia
| |
Collapse
|
29
|
Detection and Analyses of Latent DNA. FORENSIC SCIENCE INTERNATIONAL GENETICS SUPPLEMENT SERIES 2022. [DOI: 10.1016/j.fsigss.2022.09.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
30
|
Reither JB, van Oorschot RAH, Szkuta B. DNA transfer between worn clothing and flooring surfaces with known histories of use. Forensic Sci Int Genet 2022; 61:102765. [PMID: 36007265 DOI: 10.1016/j.fsigen.2022.102765] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Revised: 07/27/2022] [Accepted: 08/14/2022] [Indexed: 11/04/2022]
Abstract
DNA samples recovered from items of clothing are often attributed to the wearer and one or more individuals who may have contacted the item during an alleged criminal activity. Another scenario often proposed by defence counsel is that DNA was transferred from a previously contacted item/surface unrelated to the activity of interest onto the item of clothing. Under such scenarios, DNA may also be transferred from the clothing to the item/surface with which it comes into contact. One such surface is flooring, upon which clothing may be placed while not being worn or may be contacted during wearing, such as falling or being forced to the ground. This study investigates the transfer of DNA to and from clothing and flooring when different contacts are applied between the two surfaces in an environment representative of what investigators would encounter in routine casework, a residential environment. Participants were provided with two sets of new and unused upper and lower garments to wash then wear for ~8 h inside their own home before storing them in paper evidence bags. The two sets of clothing were taken to a home occupied by unrelated individuals, where one set was placed on the floor ('passive') by the researcher while the other was worn by the participant who laid with their back on the floor, rolled to one side and back, then stood up ('active'). Within the houses sampled, the main bedroom was targeted as flooring types and histories of use were more consistent across houses and less variation in DNA profile composition was previously observed for samples collected in the same room. Samples were collected from predetermined areas of the clothing and flooring where contact did and did not occur. Reference profiles were obtained from wearers and individuals they lived with, as well as occupants of the home. DNA transfer was observed from clothing to flooring and from flooring to clothing in both 'active' and 'passive' situations, though greater where a situation involved the application of pressure and friction ('active'), and only where contact between clothing and flooring occurred. Results from this study inform on the composition of DNA profiles one is likely to obtain from an item of clothing or a flooring surface following a similar contact event between the two substrates and will aid investigators when interpreting DNA evidence recovered in a domestic environment and the activities leading to its transfer and subsequent recovery.
Collapse
Affiliation(s)
- Jack B Reither
- School of Life and Environmental Sciences, Deakin University, Geelong, VIC 3220, Australia; Office of the Chief Forensic Scientist, Victoria Police Forensic Services Department, Macleod, VIC 3085, Australia.
| | - Roland A H van Oorschot
- Office of the Chief Forensic Scientist, Victoria Police Forensic Services Department, Macleod, VIC 3085, Australia; School of Agriculture, Biomedicine and Environment, La Trobe University, Bundoora, VIC 3086, Australia
| | - Bianca Szkuta
- School of Life and Environmental Sciences, Deakin University, Geelong, VIC 3220, Australia
| |
Collapse
|
31
|
Griffin A, Kirkbride KP, Henry J, Ben Painter, Linacre A. DNA on drugs (part 2): An extended study into the transfer and persistence of DNA onto illicit drug capsules using realistic scenarios. Forensic Sci Int Genet 2022; 60:102740. [PMID: 35716495 DOI: 10.1016/j.fsigen.2022.102740] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 06/07/2022] [Accepted: 06/10/2022] [Indexed: 11/15/2022]
Abstract
Capsules are now the main form of ecstasy rather than tablets in Australia and therefore their examination is of interest to forensic drug chemists in Australia and possibly elsewhere. Recently, we used controlled experimental conditions to show that capsules may be a source of DNA that can be used to identify those involved in production and distribution of illicit drugs. The question remains: in realistic scenarios where there are more unknowns, can we still detect DNA, and determine whose it is, on the exterior of capsules? The concept of comprehensive forensic intelligence and investigations - utilizing both biological and chemical signatures - relating to illicit drug preparations (i.e., the capsules and their contents) may be of great use to law enforcement. Experiments were conducted with both semi-realistic and realistic scenarios where two volunteers were asked to firstly use an encapsulator and mimic the loading of capsules, then Volunteer 1 would count out the capsules that Volunteer 2 prepared, and vice versa. This was to simulate the scenario where one person was involved in the assembly of the capsules which were then separated into smaller bags of 10 capsules by a second person for distribution. Gelatine and vegetable capsules were tested, with 10 replicates used per capsule type, scenario, and volunteer (total n = 80 capsules). Volunteer 2 was included as a contributor to the DNA profiles generated from 100% of samples handled by them within the semi-realistic scenario, whereas the other volunteer could be included as a contributor in 65% of samples. For the realistic scenario, profiles could be generated with the inclusion of both volunteers as profile contributors in 15% of samples and from just one of the volunteers in a further 50% of samples (therefore in total, either both or one of the volunteers were detected in 65% of realistic samples). Surprisingly, it was not necessarily the case that the last person to handle the capsule was the major or only contributor. The potential variability in the DNA quantities that could be deposited onto the capsules of genuine illicit drugs is high and would vary on a case-by-case basis. Nevertheless, this study has indicated that in realistic scenarios where two people are involved in the later stages of illicit drug capsule preparation, that either one or both individuals may be identified, potentially opening new investigative leads for law enforcement agencies as well as offering new information for intelligence-led policing.
Collapse
Affiliation(s)
- Amy Griffin
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia.
| | - K Paul Kirkbride
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia
| | - Julianne Henry
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia; Forensic Science SA, GPO Box 2790, Adelaide 5000, Australia
| | - Ben Painter
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia; Forensic Science SA, GPO Box 2790, Adelaide 5000, Australia
| | - Adrian Linacre
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia
| |
Collapse
|
32
|
Atkinson K, Arsenault H, Taylor C, Volgin L, Millman J. Transfer and persistence of DNA on items routinely encountered in forensic casework following habitual and short-duration one-time use. Forensic Sci Int Genet 2022; 60:102737. [PMID: 35753208 DOI: 10.1016/j.fsigen.2022.102737] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 05/19/2022] [Accepted: 06/06/2022] [Indexed: 11/04/2022]
Abstract
Empirical data obtained from controlled experiments is necessary to ensure that sound expert opinion evidence is provided regarding transfer and persistence of DNA in criminal proceedings. Knowledge in this area is also required at the outset of criminal investigations, to ensure that the proposed examinations can assist with answering questions that are relevant to forensic investigations. This study aimed to provide such data by examining the relative and absolute quantities of DNA deposited on items that are routinely submitted to the forensic laboratory by a habitual user, defined as someone who used it for ~1 week, and a subsequent one-time user. We found that the quantity of DNA deposited on routine household items spanned a broad range. The habitual user's DNA was detected on most items as the major donor, regardless of whether it was subsequently handled by another person for a short period of time. The one-time, short duration, user's DNA was detected on approximately two thirds of the items, albeit typically at quantities lower than the habitual user. Most of the household items we examined also had detectable DNA deposits from at least one other, unknown individual, typically in low quantities. Attempts to clean non-porous items with readily available household cleaners were partially effective but failed to completely eliminate detectable DNA from a habitual user in most cases.
Collapse
Affiliation(s)
- Kirsty Atkinson
- Centre of Forensic Sciences, 25 Morton Shulman Avenue, Toronto, Ontario M3M 0B1, Canada
| | - Hilary Arsenault
- Centre of Forensic Science, Royal College Building, University of Strathclyde, 204 George Street, Glasgow, Scotland G1 1XW, United Kingdom
| | - Christian Taylor
- Centre of Forensic Sciences, 25 Morton Shulman Avenue, Toronto, Ontario M3M 0B1, Canada
| | - Luke Volgin
- Forensic Science SA, PO Box 2790, Adelaide, SA 5000, Australia
| | - Jonathan Millman
- Centre of Forensic Sciences, 25 Morton Shulman Avenue, Toronto, Ontario M3M 0B1, Canada.
| |
Collapse
|
33
|
DNA deposited in whole thumbprints: a reproducibility study. Forensic Sci Int Genet 2022; 58:102683. [DOI: 10.1016/j.fsigen.2022.102683] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 02/21/2022] [Accepted: 02/24/2022] [Indexed: 01/27/2023]
|
34
|
Martin B, Taylor D, Linacre A. Exploring tapelifts as a method for dual workflow STR amplification. Forensic Sci Int Genet 2021; 57:102653. [PMID: 34920191 DOI: 10.1016/j.fsigen.2021.102653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 10/28/2021] [Accepted: 12/08/2021] [Indexed: 11/30/2022]
Abstract
Although a version of direct PCR is implemented in forensic laboratories for reference material, its incorporation into workflow for the analysis of touch DNA, as a form of latent DNA, from casework exhibits is not. In addition to concerns about increased sensitivity causing more complex mixtures or the generation of more genetic data implicating an individual superfluous to the context of the alleged event, the complete use of the collected sample in the PCR as template has meant that there is no possibility for data reproducibility when needed. Here it is proposed that the use of tapelifts in touch DNA collection can facilitate replicate direct PCR analysis from a single sample allowing the sample to be re-tested. If all portions of the tapelift result in profiles with allelic and likelihood ratio concordance, these sub-samples may be accepted as technical replicates, thus meeting any accreditation guideline requirements. Furthermore, we assess the use of a single tapelift for both direct PCR and extraction-based PCR workflows to illustrate the potential for benefits of both systems to be facilitated. DNA was deposited by three donors onto six substrates with five sample replicates of each condition. Separation of each tapelift into three portions for three direct PCRs ensued using VeriFiler™ Plus. Separation of single tapelifts into three direct PCRs showed no statistical difference in donor allele calls or RFU, or subsequent LRs associated with their profiles. Comparison of profiles within the single tapelift showed more similarity, with high mixture-to-mixture match likelihoods, than when these sub-samples were compared with profiles generated from other samples. This allows each sub-sample taken from the tapelift to be considered as technical replicates. For dual workflow facilitation assessment, one donor deposited DNA through touch onto six substrates with five research replicates of each. Separation of single tapelifts into two portions, one for direct PCR and the retention and use of the remaining portion for extraction and subsequent PCR, showed no significant difference in allelic yield and subsequent donor comparison LRs. Comparison of deconvoluted profiles produced from a single tapelift showed high mixture-to-mixture match likelihoods, supporting DNA donor concordance. This indicates that removing a portion of a tapelift for direct PCR amplification, while processing the remainder through standard processes, allows increased sensitivity through direct PCR while offering the preparation of an eluate suitable for repeated analyses.
Collapse
Affiliation(s)
- Belinda Martin
- Biological Sciences Building, Flinders University, Bedford Park 5042, Australia; Biological Sciences Building, College of Science and Engineering, Flinders University, Bedford Park 5042, Australia.
| | - Duncan Taylor
- Biological Sciences Building, Flinders University, Bedford Park 5042, Australia; Biological Sciences Building, College of Science and Engineering, Flinders University, Bedford Park 5042, Australia; Forensic Science South Australia, 21 Divett Pl, Adelaide, SA 5000, Australia
| | - Adrian Linacre
- Biological Sciences Building, Flinders University, Bedford Park 5042, Australia; Biological Sciences Building, College of Science and Engineering, Flinders University, Bedford Park 5042, Australia
| |
Collapse
|
35
|
Mercer C, Henry J, Taylor D, Linacre A. What's on the bag? The DNA composition of evidence bags pre- and post-exhibit examination. Forensic Sci Int Genet 2021; 57:102652. [PMID: 34896975 DOI: 10.1016/j.fsigen.2021.102652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Revised: 11/08/2021] [Accepted: 12/05/2021] [Indexed: 11/29/2022]
Abstract
Current forensic DNA profiling kits and techniques enable the detection of trace amounts of DNA. With advancements in kit sensitivity, there is an increased probability of detecting DNA from contamination. Research into DNA transfer within operational forensic laboratories provides insight into the possible mechanisms that may lead to exhibit contamination. To gain a greater understanding of the potential for evidence bags to act as DNA transfer vectors, the level of DNA accumulating on the exterior of evidence bags during the exhibit examination process was investigated. The exterior of 60 evidence bags were tapelifted before and after the examination of the exhibit inside of the bag resulting in 120 DNA profiles. These DNA profiles were compared to DNA profiles of staff working within the building and samples taken from the exhibit inside the bag. Common DNA profile contributors from each sample were also identified through STRmix™ mixture to mixture analysis. The average DNA quantity and number of profile contributors was higher in samples taken from the bag before exhibit examination than after examination. Fifty six percent of all samples taken identified a match between DNA recovered from the evidence bag and at least one staff member. On 11 bags, a common contributor was identified between the exhibit in the bag and the exhibit package post-examination. In one instance a DNA profile, matching that of a donor, on the exhibit bag before examination was also detected on a sample taken from the exhibit, raising the possibility of outer bag-to-exhibit DNA contamination. This study demonstrates that operational forensic laboratories must consider exhibit packages as a potential source of DNA contamination and evaluate their exhibit handling and storage procedures accordingly.
Collapse
Affiliation(s)
- Claire Mercer
- College of Science and Engineering, Flinders University, Bedford Park, South Australia 5042, Australia.
| | - Julianne Henry
- College of Science and Engineering, Flinders University, Bedford Park, South Australia 5042, Australia; Forensic Science SA, GPO Box 2790, Adelaide 5001, Australia
| | - Duncan Taylor
- College of Science and Engineering, Flinders University, Bedford Park, South Australia 5042, Australia; Forensic Science SA, GPO Box 2790, Adelaide 5001, Australia
| | - Adrian Linacre
- College of Science and Engineering, Flinders University, Bedford Park, South Australia 5042, Australia
| |
Collapse
|
36
|
Martin B, Kaesler T, Kirkbride KP, Linacre A. The influences of dusty environments on the STR typing success of post-detonation touch DNA samples. Forensic Sci Int Genet 2021; 57:102651. [PMID: 34896974 DOI: 10.1016/j.fsigen.2021.102651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 12/02/2021] [Accepted: 12/03/2021] [Indexed: 11/04/2022]
Abstract
As the use of improvised explosive devices (IEDs) in a broad spectrum of offences continues, it is vital that research is performed to assess the capabilities of the forensic DNA profiling technology currently available to provide information as to potential perpetrators. This work investigates some of the most important gaps in our understanding surrounding the poor success rates in DNA profiling obtained through the sampling of touch DNA on post-detonation IED samples. It has been previously suggested that the use of Diamond™ Nucleic Acid Dye may fix cells to a surface, therefore reducing the effect of an experimental process to remove or damage those cells. This was found not to be the case for samples undergoing a detonation as there was no difference in the resultant post-detonation profiles between the stained samples, stained prior to detonation, and unstained samples. The comparison of data from previously performed research, within an enclosed explosives chamber, to real-world outdoor detonation events in a rural and dusty environment was investigated. It was found that there was a significant difference between the environments for the aluminium but not for the battery or electrical tape substrates indicating that environment has the potential to influence STR success through the introduction of PCR inhibitors; humic acid within rural natural dust was introduced here. No difference was observed in cell loss due to the detonation between environments and the dirt within the PCR was higher in the 'outdoor' samples. The effect on cellular retention and damage due to the sample's distance from the charge has been thoroughly investigated through incremental 100 mm exposure. Distance from the charge was found to affect every metric analysed; these being the cell loss from samples, the number of alleles amplified in resultant direct PCR profiles, and the total RFU of the subsequent profiles. These data outline the importance of this work allowing results to be assessed and triage decisions be made accordingly. The analysis of wood, PVC pipe, a mobile phone with rubber buttons, a SIM card, and a circuit board showed that none of these samples at 400 mm from the charge caused substrate specific PCR inhibition. On-site collection teams do not need to triage collection based on these sample types as there was no significant difference observed in their ability to return DNA profiling data. Surface area and inhibitor presence are key variables to consider when determining STR processing workflow for post-detonation samples as for samples with larger surface areas within the outdoor environment PCR post-extraction is preferential to direct PCR.
Collapse
Affiliation(s)
- Belinda Martin
- College of Science and Engineering, FlindersUniversity; Biological Sciences Building, 5042 Bedford Park, South Australia, Australia.
| | - Todd Kaesler
- College of Science and Engineering, FlindersUniversity; Biological Sciences Building, 5042 Bedford Park, South Australia, Australia
| | - K Paul Kirkbride
- College of Science and Engineering, FlindersUniversity; Biological Sciences Building, 5042 Bedford Park, South Australia, Australia
| | - Adrian Linacre
- College of Science and Engineering, FlindersUniversity; Biological Sciences Building, 5042 Bedford Park, South Australia, Australia
| |
Collapse
|
37
|
Schmidt M, Bamberg M, Dierig L, Kunz SN, Wiegand P. Casework-related DNA transfer on footwear in consideration of the shedder status. Forensic Sci Int Genet 2021; 56:102630. [PMID: 34808489 DOI: 10.1016/j.fsigen.2021.102630] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 10/29/2021] [Accepted: 11/02/2021] [Indexed: 11/04/2022]
Abstract
DNA evidence on shoes can play an important role in solving a variety of crimes. We investigated the transfer, persistence, prevalence and recovery of DNA (DNAtppr) on shoes (sneakers) and their soles in realistic handling scenarios taking into account the shedder status. This study aims to increase the understanding of the expected composition of DNA profiles and their probative value, providing a basis for activity level assessments. Samples were analyzed using a direct lysis method, suggesting its versatility and increasing the DNA typing success compared to previous studies on footwear. The data showed surface-dependent background DNA (bDNA) levels on shoe soles and prevalence of bDNA on the upper parts of the shoe. The owner of the shoe was allocatable to the mixture for almost every shoe and sampling location. Alternating scenarios of shoe handling were simulated through different pairs of shedders to distinguish shoe owner and subsequent user. Secondary users were attributable to DNA mixtures regardless of shedder status after wearing shoes a single time. The influence of the shedder status follows specific trends in this context. However, particularly intermediate shedders show inconsistent results. The prevalence of bDNA appears to have a greater effect on the impact of the shedder status on DNA profile composition than previously reported. The data help researchers to better resolve suspect statements and determine if a person of interest wore the shoes relevant to the investigation.
Collapse
Affiliation(s)
- Max Schmidt
- Institute of Legal Medicine, University Ulm, Albert-Einstein-Allee 23, 89081 Ulm, Germany.
| | - Malte Bamberg
- Institute of Legal Medicine, University Ulm, Albert-Einstein-Allee 23, 89081 Ulm, Germany
| | - Lisa Dierig
- Institute of Legal Medicine, University Ulm, Albert-Einstein-Allee 23, 89081 Ulm, Germany
| | - Sebastian N Kunz
- Institute of Legal Medicine, University Ulm, Albert-Einstein-Allee 23, 89081 Ulm, Germany
| | - Peter Wiegand
- Institute of Legal Medicine, University Ulm, Albert-Einstein-Allee 23, 89081 Ulm, Germany
| |
Collapse
|
38
|
Thornbury D, Goray M, van Oorschot RAH. Transfer of DNA without contact from used clothing, pillowcases and towels by shaking agitation. Sci Justice 2021; 61:797-805. [PMID: 34802654 DOI: 10.1016/j.scijus.2021.10.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 09/10/2021] [Accepted: 10/06/2021] [Indexed: 10/20/2022]
Abstract
DNA is frequently retrieved from commonly used objects or surfaces with no apparent biological stains. This DNA may have come from one or more individuals who directly deposited their DNA, or indirectly transferred the DNA of others, when physically contacting the sampled object or surface. Furthermore, contactless indirect DNA transfer of this 'touch DNA' from fabric substrates was recently demonstrated to be possible in a controlled laboratory environment. The circumstances and extent to which this form of contactless DNA transfer occurs are largely unknown. This study investigated indirect DNA transfer without contact by applying a gentle shaking agitation to used clothing, pillowcases and towels, with known usage and history, of 10 volunteers above the collection zone of the secondary surface. DNA transfer frequently occurred and was possible from all three investigated items. It occurred at levels that often produced informative profiles where transferred profiles closely resembled the profiles generated from the primary item. The outcomes of this study contribute to expanding the understanding of indirect DNA transfer without contact. However, this field would benefit from investigating a wider range of agitations and/or item types with various histories of use to determine the level of transfer and its detectability under different conditions.
Collapse
Affiliation(s)
- Devon Thornbury
- School of Life Sciences, La Trobe University, Bundoora, Australia; Office of the Chief Forensic Scientist, Victoria Police Forensic Services Department, Macleod, Australia.
| | - Mariya Goray
- Biometrics Division, Victoria Police Forensic Services Department, Macleod, Australia; College of Science & Engineering, Flinders University, Adelaide 5042, Australia
| | - Roland A H van Oorschot
- Office of the Chief Forensic Scientist, Victoria Police Forensic Services Department, Macleod, Australia; School of Molecular Sciences, La Trobe University, Bundoora, Australia
| |
Collapse
|
39
|
Hughes DA, Szkuta B, van Oorschot RAH, Conlan XA. "Technical Note:" Optimisation of Diamond™ Nucleic Acid Dye preparation, application, and visualisation, for latent DNA detection. Forensic Sci Int 2021; 330:111096. [PMID: 34794062 DOI: 10.1016/j.forsciint.2021.111096] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 10/13/2021] [Accepted: 11/01/2021] [Indexed: 11/19/2022]
Abstract
A targeted sampling approach of latent DNA, deposited when a person makes contact with a surface, can prove challenging during crime scene or evidence processing, with the sampling of latent DNA often relying on the expert judgement from crime scene officers and forensic examiners. As such, the ability to use the quick and robust screening tool Diamond™ Nucleic Acid Dye (DD) was explored, with a focus on the visualisation of latent DNA on non-porous substrates, namely polypropylene, acrylic, aluminium, PVC composite material, glass, and crystalline silicon. The application of DD was performed according to methods reported in literature, where 10 µL of the dye solution (20-fold dilution of DD in 75% EtOH) was applied onto a variety of non-porous substrates via a micropipette and then subsequently visualised using a portable fluorescence microscope. It was discovered that there was scope for improvement in the reported methods due to the observation of crystal formations on all test substrates upon drying of the DD, resulting in the impaired visualisation of latent DNA and fingerprint detail. Thus, changes to the EtOH water ratio of the dye solution, and changes to the mode of dye application from a micropipette to a spray application, were explored to improve the drying time of the dye and mitigate the formation of crystals. While changes to the EtOH water ratio did not improve the overall drying time, the mode of dye application enhanced visualisation, with a spray application eliminating the formation of crystals no matter the EtOH water ratio. Visualisation with a portable Dino-Lite and Zeiss Widefield fluorescence microscope were also explored, with the Zeiss Widefield fluorescence microscope proving to be useful in whole print imaging and a more efficient imaging tool in a laboratory setting.
Collapse
Affiliation(s)
- Deborah A Hughes
- Deakin University, School of Life and Environmental Sciences, Geelong, Victoria, Australia
| | - Bianca Szkuta
- Deakin University, School of Life and Environmental Sciences, Geelong, Victoria, Australia; Office of the Chief Forensic Scientist, Victoria Police Forensic Services Centre, Macleod, Victoria, Australia
| | - Roland A H van Oorschot
- Office of the Chief Forensic Scientist, Victoria Police Forensic Services Centre, Macleod, Victoria, Australia; School of Molecular Sciences, La Trobe University, Bundoora, Victoria, Australia
| | - Xavier A Conlan
- Deakin University, School of Life and Environmental Sciences, Geelong, Victoria, Australia.
| |
Collapse
|
40
|
Jansson L, Swensson M, Gifvars E, Hedell R, Forsberg C, Ansell R, Hedman J. Individual shedder status and the origin of touch DNA. Forensic Sci Int Genet 2021; 56:102626. [PMID: 34781198 DOI: 10.1016/j.fsigen.2021.102626] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 10/27/2021] [Accepted: 10/27/2021] [Indexed: 11/17/2022]
Abstract
Due to improved laboratory techniques, touched surfaces and items are increasingly employed as sources of forensic DNA evidence. This has urged a need to better understand the mechanisms of DNA transfer between individuals. Shedder status (i.e. the propensity to leave DNA behind) has been identified as one major factor regulating DNA transfer. It is known that some individuals tend to shed more DNA than others, but the mechanisms behind shedder status are largely unknown. By comparing the amounts of DNA deposited from active hands (i.e. used "as usual") and inactive hands (i.e. not allowed to touch anything), we show that some of the self-DNA deposited from hands is likely to have accumulated on hands from other parts of the body or previously handled items (active hands: 2.1 ± 2.7 ng, inactive hands: 0.83 ± 1.1 ng, paired t-test: p = 0.014, n = 27 pairs of hands). Further investigation showed that individual levels of deposited DNA are highly associated with the level of DNA accumulation on the skin of the face (Pearson's correlation: r = 0.90, p < 0.00001 and Spearman's ranked correlation: rs = 0.56, p = 0.0016, n = 29). We hypothesized that individual differences in sebum secretion levels could influence the amount of DNA accumulation in facial areas, but no such correlation was seen (Pearson's correlation: r = - 0.13, p = 0.66, n = 14). Neither was there any correlation between DNA levels on hands or forehead and the time since hand or face wash. We propose that the amount of self-DNA deposited from hands is highly influenced by the individual levels of accumulated facial DNA, and that cells/DNA is often transferred to hands by touching or rubbing one's face.
Collapse
Affiliation(s)
- Linda Jansson
- National Forensic Centre, Swedish Police Authority, Linköping, Sweden; Applied Microbiology, Department of Chemistry, Lund University, Lund, Sweden
| | - Marie Swensson
- Applied Microbiology, Department of Chemistry, Lund University, Lund, Sweden
| | - Emma Gifvars
- Applied Microbiology, Department of Chemistry, Lund University, Lund, Sweden
| | - Ronny Hedell
- National Forensic Centre, Swedish Police Authority, Linköping, Sweden
| | | | - Ricky Ansell
- National Forensic Centre, Swedish Police Authority, Linköping, Sweden; Department of Physics, Chemistry and Biology, IFM, Linköping University, Linköping, Sweden
| | - Johannes Hedman
- National Forensic Centre, Swedish Police Authority, Linköping, Sweden; Applied Microbiology, Department of Chemistry, Lund University, Lund, Sweden.
| |
Collapse
|
41
|
Bathrick AS, Norsworthy S, Plaza DT, McCormick MN, Slack D, Ramotowski RS. DNA recovery after sequential processing of latent fingerprints on copy paper. J Forensic Sci 2021; 67:149-160. [PMID: 34498754 PMCID: PMC9291209 DOI: 10.1111/1556-4029.14881] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Revised: 07/22/2021] [Accepted: 08/17/2021] [Indexed: 12/01/2022]
Abstract
Forensic examiners must determine whether both latent fingerprint development and DNA profiling can be performed on the same area of an evidence item and, if only one is possible, which examination offers the best chance for identification. Latent fingerprints can be enhanced by targeting different components of fingerprint residues with sequential chemical treatments. This study investigated the effects of single-reagent and sequential latent fingerprint development processes on downstream DNA analysis to determine the point at which latent fingerprint development should be stopped to allow for DNA recovery. Latent fingerprints deposited on copy paper by one donor were developed using three sequential processes: 1,8-diazafluoren-9-one (DFO) → ninhydrin → physical developer (PD); 1,2-indanedione-zinc (IND-Zn) → ninhydrin → PD; and IND-Zn → ninhydrin → Oil Red O (ORO) → PD. Samples were examined after the addition of each chemical treatment. DNA was collected with cotton swabs, extracted, quantified, and amplified. DNA yields, peak heights, number of alleles obtained, and percentage of DNA profiles eligible for CODIS upload were examined. DNA profiles were obtained with varying degrees of success, depending on the number and type of treatments used for latent fingerprint development. The treatments that were found to be the least harmful to downstream DNA analysis were IND-Zn and IND-Zn/laser, and the most detrimental treatments were DFO, DFO/laser, and PD. In general, as the number of treatments increase, the opportunities for DNA loss or damage also increase, and it is preferable to use fewer treatments when developing latent fingerprints prior to downstream DNA processing.
Collapse
Affiliation(s)
| | - Sarah Norsworthy
- Forensic Technology Center of Excellence, RTI International, Research Triangle Park, NC, USA
| | | | - Mallory N McCormick
- Forensic Services Division, United States Secret Service, Washington, DC, USA
| | - Donia Slack
- Forensic Technology Center of Excellence, RTI International, Research Triangle Park, NC, USA
| | - Robert S Ramotowski
- Forensic Services Division, United States Secret Service, Washington, DC, USA
| |
Collapse
|
42
|
Cook R, Mitchell N, Henry J. Assessment of Diamond™ Nucleic Acid Dye for the identification and targeted sampling of latent DNA in operational casework. Forensic Sci Int Genet 2021; 55:102579. [PMID: 34455366 DOI: 10.1016/j.fsigen.2021.102579] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 08/04/2021] [Accepted: 08/15/2021] [Indexed: 12/19/2022]
Abstract
Recovery and DNA profiling of latent touch DNA deposits is a ubiquitous practice by operational forensic laboratories that provides critical evidence in many criminal investigations. Despite recent improvements in the sensitivity of contemporary DNA profiling kits, the inability to localise and visually quantify touch DNA deposits on an exhibit means that ineffective or unwarranted sampling is often performed leading to poor success. Diamond™ Nucleic Acid Dye (DD) is a fluorescent DNA binding dye which has recently been shown to bind to corneocytes enabling visualisation and targeted sampling of touch DNA deposits under controlled conditions. The ability to translate these findings to operational casework, where a diverse range of substrates is encountered and the amount and distribution of touch DNA is uncontrolled, is currently unknown. Here, we provide the first report on the use of DD in an operational context. Spraying items with DD was shown to have no impact on downstream immunological testing, DNA extraction, or DNA profiling with the GlobalFiler™ PCR amplification kit. DD was shown to effectively locate areas of touch DNA on select exhibits using the Polilight. Issues with background fluorescence, non-specific staining, interference from fingerprint enhancement reagents, or absorbance of the excitation light by black surfaces demonstrated that DD is not compatible with all exhibits. Background fluorescence also prevented the use of DD to screen for the presence of cellular material on IsoHelix swabs post-sampling but it was suitable for screening Lovell DNA tapelifts. A casework trial of 49 plastic bag and tape exhibits showed limited application of DD to triage out negative items as DNA was recovered from items where DD fluorescence was not detected. Where DD fluorescence was detected, its broad distribution prevented targeted sampling and any correlation to be made between the amount observed and DNA yield or profiling outcome. The DD procedure also increased the time taken to search exhibits and risk of inadvertent contamination. Our study suggests that DD is not suited as a generalised screening technique across all touch casework exhibits but further investigation is warranted to determine its applicability to specific exhibit types.
Collapse
Affiliation(s)
- Russell Cook
- Forensic Science SA, GPO Box 2790, Adelaide, South Australia 5001, Australia
| | - Natasha Mitchell
- Forensic Science SA, GPO Box 2790, Adelaide, South Australia 5001, Australia
| | - Julianne Henry
- Forensic Science SA, GPO Box 2790, Adelaide, South Australia 5001, Australia; College of Science and Engineering, Flinders University of South Australia, Bedford Park, South Australia 5042, Australia.
| |
Collapse
|
43
|
Ahannach S, Spacova I, Decorte R, Jehaes E, Lebeer S. At the Interface of Life and Death: Post-mortem and Other Applications of Vaginal, Skin, and Salivary Microbiome Analysis in Forensics. Front Microbiol 2021; 12:694447. [PMID: 34394033 PMCID: PMC8355522 DOI: 10.3389/fmicb.2021.694447] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Accepted: 06/14/2021] [Indexed: 12/13/2022] Open
Abstract
Microbial forensics represents a promising tool to strengthen traditional forensic investigative methods and fill related knowledge gaps. Large-scale microbiome studies indicate that microbial fingerprinting can assist forensics in areas such as trace evidence, source tracking, geolocation, and circumstances of death. Nevertheless, the majority of forensic microbiome studies focus on soil and internal organ samples, whereas the microbiome of skin, mouth, and especially vaginal samples that are routinely collected in sexual assault and femicide cases remain underexplored. This review discusses the current and emerging insights into vaginal, skin, and salivary microbiome-modulating factors during life (e.g., lifestyle and health status) and after death (e.g., environmental influences and post-mortem interval) based on next-generation sequencing. We specifically highlight the key aspects of female reproductive tract, skin, and mouth microbiome samples relevant in forensics. To fill the current knowledge gaps, future research should focus on the degree to which the post-mortem succession rate and profiles of vaginal, skin, and saliva microbiota are sensitive to abiotic and biotic factors, presence or absence of oxygen and other gases, and the nutrient richness of the environment. Application of this microbiome-related knowledge could provide valuable complementary data to strengthen forensic cases, for example, to shed light on the circumstances surrounding death with (post-mortem) microbial fingerprinting. Overall, this review synthesizes the present knowledge and aims to provide a framework to adequately comprehend the hurdles and potential application of vaginal, skin, and salivary post-mortem microbiomes in forensic investigations.
Collapse
Affiliation(s)
- Sarah Ahannach
- Department of Bioscience Engineering, Research Group Environmental Ecology and Applied Microbiology, University of Antwerp, Antwerp, Belgium
| | - Irina Spacova
- Department of Bioscience Engineering, Research Group Environmental Ecology and Applied Microbiology, University of Antwerp, Antwerp, Belgium
| | - Ronny Decorte
- Laboratory of Forensic Genetics, Department of Forensic Medicine, University Hospitals Leuven, Leuven, Belgium.,Department of Imaging and Pathology, Forensic Biomedical Sciences, KU Leuven, Leuven, Belgium
| | - Els Jehaes
- Forensic DNA Laboratory, Department of Forensic Medicine, Antwerp University Hospital, Edegem, Belgium
| | - Sarah Lebeer
- Department of Bioscience Engineering, Research Group Environmental Ecology and Applied Microbiology, University of Antwerp, Antwerp, Belgium
| |
Collapse
|
44
|
Vennemann M, Oppelt C, Grethe S, Anslinger K, Fimmers R, Schneider H, Hohoff C, Eckert M, Rothämel T, Schneider PM. Möglichkeiten und Grenzen der forensischen DNA-Analyse unter dem Gesichtspunkt verschiedener Szenarien zur Spurenentstehung. Rechtsmedizin (Berl) 2021. [DOI: 10.1007/s00194-021-00508-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
45
|
Prasad E, Atwood L, van Oorschot RAH, McNevin D, Barash M, Raymond J. Trace DNA recovery rates from firearms and ammunition as revealed by casework data. AUST J FORENSIC SCI 2021. [DOI: 10.1080/00450618.2021.1939783] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Affiliation(s)
- Elisha Prasad
- Centre for Forensic Science, School of Mathematical & Physical Sciences, Faculty of Science, University of Technology Sydney, Sydney, Australia
| | - Lauren Atwood
- Science and Research Unit, Forensic Evidence & Technical Services Command, NSW Police Force, Level 5, Sydney Police Centre, Surry Hills, Australia
| | - Roland A. H. van Oorschot
- Victoria Police Forensic Services Department, Office of the Chief Forensic Scientist, Macleod, Australia
- School of Molecular Sciences, La Trobe University, Bundoora, Australia
| | - Dennis McNevin
- Centre for Forensic Science, School of Mathematical & Physical Sciences, Faculty of Science, University of Technology Sydney, Sydney, Australia
| | - Mark Barash
- Centre for Forensic Science, School of Mathematical & Physical Sciences, Faculty of Science, University of Technology Sydney, Sydney, Australia
- Department of Justice Studies, San Jose State University, San Jose, CA, USA
| | - Jennifer Raymond
- Science and Research Unit, Forensic Evidence & Technical Services Command, NSW Police Force, Level 5, Sydney Police Centre, Surry Hills, Australia
| |
Collapse
|
46
|
Puliatti L, Handt O, Taylor D. The level of DNA an individual transfers to untouched items in their immediate surroundings. Forensic Sci Int Genet 2021; 54:102561. [PMID: 34303991 DOI: 10.1016/j.fsigen.2021.102561] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 06/24/2021] [Accepted: 07/03/2021] [Indexed: 12/01/2022]
Abstract
Due to advances in DNA profiling sensitivity as well as the implementation of various types of software to analyse these profiles, forensic biologists can provide opinions about results generated from very low levels of template DNA. The ability to obtain DNA profiles from such 'trace' DNA brings into question the mechanisms of transfer which led to it being deposited. This study investigates the level of DNA that is deposited by an individual to their work environment. DNA collection plates were placed at distances from 0.5 to 5 m from individuals' office desks and left for 1 day to 6 weeks before being swabbed and profiled with GlobalFiler. The results from this study indicate that an individual can deposit DNA in areas they were present, even if surfaces and/or objects were not directly contacted and even after only one day. Distance from a person, the length of time and the person themselves all play a role in the quantity of DNA that is deposited to one's surroundings.
Collapse
Affiliation(s)
- Lucas Puliatti
- School of Biological Sciences, Flinders University, GPO Box 2100, Adelaide, South Australia 5001, Australia
| | - Oliva Handt
- School of Biological Sciences, Flinders University, GPO Box 2100, Adelaide, South Australia 5001, Australia; Forensic Science SA, PO Box 2790, Adelaide, South Australia 5000, Australia
| | - Duncan Taylor
- School of Biological Sciences, Flinders University, GPO Box 2100, Adelaide, South Australia 5001, Australia; Forensic Science SA, PO Box 2790, Adelaide, South Australia 5000, Australia.
| |
Collapse
|
47
|
Shedder status: Exploring means of determination. Sci Justice 2021; 61:391-400. [DOI: 10.1016/j.scijus.2021.03.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Revised: 03/09/2021] [Accepted: 03/13/2021] [Indexed: 01/29/2023]
|
48
|
Griffin A, Kirkbride KP, Henry J, Painter B, Linacre A. DNA on drugs! A preliminary investigation of DNA deposition during the handling of illicit drug capsules. Forensic Sci Int Genet 2021; 54:102559. [PMID: 34225041 DOI: 10.1016/j.fsigen.2021.102559] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 06/23/2021] [Accepted: 06/25/2021] [Indexed: 10/21/2022]
Abstract
DNA profiling from capsules and tablets offers a complementary tool to that of chemical profiling when investigating the manufacture and trade in illicit drugs. By sampling the outside of capsules, individuals who may have handled them during production, assembly or distribution may have deposited their DNA and can be identified if matched to a nominated profile or one on a relevant DNA database. The profiles can also be compared to those found on other capsules to potentially link various drug seizures. This study sampled the exterior of capsules after they had been handled in a controlled scenario to determine if informative DNA profiles could be generated from this brief contact. Two individuals of intermediate shedder status washed their hands and waited for 30 min before handling ten gelatine, vegetable, and enteric vegetable capsules each (n = 60). Contact was made for 15 s. Each capsule was swabbed and DNA isolated. The amount of recovered human DNA was quantified and profiled using the Verifiler Plus DNA profiling kit. Profiles were generated from 82% (49/60) of capsules tested with LR values above 1 × 103 for the inclusion of the volunteer as a contributor. Inhibition of the PCR was detected in 24 of the 60 samples, however 16 of these still produced informative profiles when sufficient template DNA was available and only mild inhibition was detected, or by overcoming inhibition by dilution of the DNA extract. This pilot study demonstrates the potential for forensic science laboratories to recover human DNA from the exterior surface of capsules which are commonly used to encase illicit drugs such as MDMA, thus enabling both biological and chemical profiling methods to contribute to the investigation of clandestine drug production and distribution.
Collapse
Affiliation(s)
- Amy Griffin
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia.
| | - K Paul Kirkbride
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia
| | - Julianne Henry
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia; Forensic Science SA, GPO Box 2790, Adelaide, Australia
| | - Ben Painter
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia; Forensic Science SA, GPO Box 2790, Adelaide, Australia
| | - Adrian Linacre
- College of Science & Engineering, Flinders University, Adelaide 5042, Australia
| |
Collapse
|
49
|
Burrill J, Hotta R, Daniel B, Frascione N. Accumulation of endogenous and exogenous nucleic acids in "Touch DNA" components on hands. Electrophoresis 2021; 42:1594-1604. [PMID: 34080688 DOI: 10.1002/elps.202000371] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 05/07/2021] [Accepted: 05/20/2021] [Indexed: 02/03/2023]
Abstract
Successful forensic DNA profiling from handled items is increasingly routine in casework. This "touch DNA" is thought to contain both cellular and acellular nucleic acid sources. However, there is little clarity on the origins or characteristics of this material. The cellular component consists of anucleate, terminally differentiated corneocytes (assumed to lack DNA), and the occasional nucleated cell. The acellular DNA source is fragmentary, presumably cell breakdown products. This study examines the relative contributions each component makes to the hand-secretions (endogenous) and hand-accumulations (exogenous) by recovering rinses from the inside and outside of worn gloves. Additionally, cellular and acellular DNA was measured at timepoints up to 2 h after hand washing, both with and without interim contact. Microscopic examination confirmed cell morphology and presence of nucleic acids. Following the novel application of a hair keratinocyte lysis method and plasma-DNA fragment purification to hand rinse samples, DNA profiles were generated from both fractions. Exogenous cell-free DNA is shown to be a significant source of touch DNA, which reaccumulates quickly, although its amplifiable nuclear alleles are limited. Endogenous DNA is mostly cellular in origin and provides more allelic information consistently over time.
Collapse
Affiliation(s)
- Julia Burrill
- King's Forensics, Department of Analytical, Environmental & Forensic Sciences, School of Population Health & Environmental Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Rachel Hotta
- King's Forensics, Department of Analytical, Environmental & Forensic Sciences, School of Population Health & Environmental Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Barbara Daniel
- King's Forensics, Department of Analytical, Environmental & Forensic Sciences, School of Population Health & Environmental Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Nunzianda Frascione
- King's Forensics, Department of Analytical, Environmental & Forensic Sciences, School of Population Health & Environmental Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| |
Collapse
|
50
|
Johannessen H, Gill P, Roseth A, Fonneløp AE. Determination of shedder status: A comparison of two methods involving cell counting in fingerprints and the DNA analysis of handheld tubes. Forensic Sci Int Genet 2021; 53:102541. [PMID: 34090062 DOI: 10.1016/j.fsigen.2021.102541] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 05/25/2021] [Accepted: 05/26/2021] [Indexed: 01/13/2023]
Abstract
The shedder status of an individual may be important to consider in the context of DNA transfer, persistence and recovery and in Bayesian networks where a person's shedder status may have an impact on the outcome. In this study we compared two methods to determine shedder status: the handheld tube (HH) method and a fluorescent cell count (CC) method. A poor association was observed between the numbers of detected cells in a fingerprint using the CC method and the strength of the DNA result with the HH method. The 20 participants were classified into low (25%), medium (50%) and high (25%) shedders based on the HH method. While the low and high shedders showed a good consistency between the replicates, the medium shedders varied more and have to be considered more carefully as they may act as either a high or a low shedder in an event of DNA transfer.
Collapse
Affiliation(s)
- Helen Johannessen
- Department of Forensic Medicine, Institute of Clinical Medicine, University of Oslo, Norway.
| | - Peter Gill
- Department of Forensic Medicine, Institute of Clinical Medicine, University of Oslo, Norway; Department of Forensic Sciences, Oslo University Hospital, Norway
| | - Arne Roseth
- Department of Forensic Sciences, Oslo University Hospital, Norway
| | | |
Collapse
|