1
|
Pan X, Huang W, Nie G, Wang C, Wang H. Ultrasound-Sensitive Intelligent Nanosystems: A Promising Strategy for the Treatment of Neurological Diseases. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2303180. [PMID: 37871967 DOI: 10.1002/adma.202303180] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 09/26/2023] [Indexed: 10/25/2023]
Abstract
Neurological diseases are a major global health challenge, affecting hundreds of millions of people worldwide. Ultrasound therapy plays an irreplaceable role in the treatment of neurological diseases due to its noninvasive, highly focused, and strong tissue penetration capabilities. However, the complexity of brain and nervous system and the safety risks associated with prolonged exposure to ultrasound therapy severely limit the applicability of ultrasound therapy. Ultrasound-sensitive intelligent nanosystems (USINs) are a novel therapeutic strategy for neurological diseases that bring greater spatiotemporal controllability and improve safety to overcome these challenges. This review provides a detailed overview of therapeutic strategies and clinical advances of ultrasound in neurological diseases, focusing on the potential of USINs-based ultrasound in the treatment of neurological diseases. Based on the physical and chemical effects induced by ultrasound, rational design of USINs is a prerequisite for improving the efficacy of ultrasound therapy. Recent developments of ultrasound-sensitive nanocarriers and nanoagents are systemically reviewed. Finally, the challenges and developing prospects of USINs are discussed in depth, with a view to providing useful insights and guidance for efficient ultrasound treatment of neurological diseases.
Collapse
Affiliation(s)
- Xueting Pan
- CAS Key Laboratory for Biomedical Effects of Nanomaterials & Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing, 100190, China
| | - Wenping Huang
- CAS Key Laboratory for Biomedical Effects of Nanomaterials & Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing, 100190, China
- School of Nanoscience and Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Guangjun Nie
- CAS Key Laboratory for Biomedical Effects of Nanomaterials & Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing, 100190, China
- School of Nanoscience and Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Changyong Wang
- Beijing Institute of Basic Medical Sciences, 27 Taiping Road, Beijing, 100850, China
| | - Hai Wang
- CAS Key Laboratory for Biomedical Effects of Nanomaterials & Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing, 100190, China
- School of Nanoscience and Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| |
Collapse
|
2
|
Ashida R, Kawabata KI, Asami R, Kitano M. Novel treatment system using endoscopic ultrasound-guided high-intensity focused ultrasound: A proof-of-concept study. Pancreatology 2024; 24:88-92. [PMID: 38036413 DOI: 10.1016/j.pan.2023.11.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 11/09/2023] [Accepted: 11/16/2023] [Indexed: 12/02/2023]
Abstract
AIM High-intensity focused ultrasound (HIFU) is a novel minimally invasive local treatment of solid tumors. Endoscopic ultrasound-guided HIFU (EUS-HIFU) using mechanical effects would have potential benefits, including precise detection of target lesions and enhance drug delivery. The aim of this study is to develop EUS-HIFU device and to prove our concept in porcine model using a locally injected phase change nano droplet (PCND) as the sensitizer. METHOD A phospholipid PCND contained volatile perfluoro-carbon liquids. The prototype HIFU apparatus comprised a small (20 × 20 mm) transducer with center frequency of 2.1 MHz, attachable to a linear EUS transducer. Under general anesthetic, a single porcine received EUS-guided injection of PCND. The HIFU transducer was placed laparotomically in the stomach, and the liver was ablated through the gastric wall. RESULTS PCND was injected successfully and a distinct lesion was generated at the HIFU transducer focus only in injected areas that received HIFU exposure at 4.7 kW/cm2 at a duty cycle of 5 % (mean temporal intensity, 0.245 kW/cm2) for 30 s. The generated lesions were mechanically fractionated in macroscopic view. CONCLUSION The concept of transluminal HIFU ablation using novel EUS-HIFU system was proved in a porcine animal model. This novel treatment system has great potential for future cancer treatment although further investigation in more animals and different organs are warranted.
Collapse
Affiliation(s)
- Reiko Ashida
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan.
| | | | - Rei Asami
- Imaging Technology Center, FUJIFILM Corporation, Tokyo, Japan
| | - Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| |
Collapse
|
3
|
Shin EJ, Park S, Kang S, Kim J, Chang JH. Improving the quality of ultrasound images acquired using a therapeutic transducer. ULTRASONICS 2023; 134:107063. [PMID: 37300907 DOI: 10.1016/j.ultras.2023.107063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 05/01/2023] [Accepted: 05/30/2023] [Indexed: 06/12/2023]
Abstract
To enhance the effectiveness and safety of focused ultrasound (FUS) therapy, ultrasound image-based guidance and treatment monitoring are crucial. However, the use of FUS transducers for both therapy and imaging is impractical due to their low spatial resolution, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). To address this issue, we propose a new method that significantly improve the quality of images obtained by a FUS transducer. The proposed method employs coded excitation to enhance SNR and Wiener deconvolution to solve the problem of low axial resolution resulting from the narrow spectral bandwidth of FUS transducers. Specifically, the method eliminates the impulse response of a FUS transducer from received ultrasound signals using Wiener deconvolution, and pulse compression is performed using a mismatched filter. Simulation and commercial phantom experiments confirmed that the proposed method significantly improves the quality of images acquired by the FUS transducer. The -6 dB axial resolution was improved 1.27 mm to 0.37 mm that was similar to the resolution achieved by the imaging transducer, i.e., 0.33 mm. SNR and CNR also increased from 16.5 dB and 0.69 to 29.1 dB and 3.03, respectively, that were also similar to those by the imaging transducer (27.8 dB and 3.16). Based on the results, we believe that the proposed method has great potential to enhance the clinical utility of FUS transducers in ultrasound image-guided therapy.
Collapse
Affiliation(s)
- Eui-Ji Shin
- Department of Electronic Engineering, Sogang University, Seoul, Korea
| | - Sunghun Park
- Department of Electronic Engineering, Sogang University, Seoul, Korea
| | - Sungwoo Kang
- Department of Electrical Engineering and Computer Science, DGIST (Daegu Gyeongbuk Institute of Science and Technology), Daegu, Korea
| | - Jinwoo Kim
- Department of Electrical Engineering and Computer Science, DGIST (Daegu Gyeongbuk Institute of Science and Technology), Daegu, Korea
| | - Jin Ho Chang
- Department of Electrical Engineering and Computer Science, DGIST (Daegu Gyeongbuk Institute of Science and Technology), Daegu, Korea.
| |
Collapse
|
4
|
Tang J, Tang J, Li H, Zhou J, Tang N, Zhu Q, Wang X, Zhu B, Li N, Liu Z. Mechanical destruction using a minimally invasive Ultrasound Needle induces anti-tumor immune responses and synergizes with the anti-PD-L1 blockade. Cancer Lett 2023; 554:216009. [PMID: 36400312 DOI: 10.1016/j.canlet.2022.216009] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/09/2022] [Accepted: 11/10/2022] [Indexed: 11/17/2022]
Abstract
Immune checkpoint inhibitors (ICIs) have been widely used in treating various tumors; however, the objective response rate of ICIs is less than 40%. In this study, we attempted to induce anti-tumor immune responses using an improved ultrasonic horn device, Ultrasound Needle (UN). We tested its synergistic anti-tumor efficacy with an anti-PD-L1 antibody in a mouse tumor model. Under different parameters, UN treatment selectively induced mechanical destruction and thermal ablation effects on tumor tissues. The mechanical destruction effect of UN treatment increased the infiltration of CD8+ T cells in tumors and relieved the immunosuppressive tumor microenvironment. It also induced systemic anti-tumor immune responses and enhanced the therapeutic efficacy of the anti-PD-L1 antibody in both local and abscopal tumors. The mechanical destruction effect of UN treatment resulted in the release of damage-associated molecular patterns and promoted dendritic cells (DCs)-based antigen presentation. Depletion of DCs or CD8+ T cells eliminated the anti-tumor immune responses induced by UN treatment and weakened the synergistic anti-tumor efficacy with anti-PD-L1 antibody. Therefore, minimally invasive UN may provide a new therapeutic modality for ultrasound-assisted immunotherapy.
Collapse
Affiliation(s)
- Jiawei Tang
- Department of Ultrasound, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, China
| | - Junhui Tang
- Department of Ultrasound, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, China
| | - Hui Li
- Department of Ultrasound, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, China
| | - Jing Zhou
- Institute of Immunology, PLA, Third Military Medical University, Chongqing, China
| | - Najiao Tang
- Zhongshan Hospital (Xiamen), Fudan University, Xiamen, China
| | - Qiong Zhu
- Department of Ultrasound, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, China
| | - Xinxin Wang
- Institute of Cancer, Xinqiao Hospital, Third Military Medical University, Chongqing, China; Chongqing Key Laboratory of Immunotherapy, Chongqing, China
| | - Bo Zhu
- Institute of Cancer, Xinqiao Hospital, Third Military Medical University, Chongqing, China; Chongqing Key Laboratory of Immunotherapy, Chongqing, China
| | - Ningshan Li
- Department of Ultrasound, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, China.
| | - Zheng Liu
- Department of Ultrasound, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, China.
| |
Collapse
|
5
|
Williams RP, Simon JC, Khokhlova VA, Sapozhnikov OA, Khokhlova TD. The histotripsy spectrum: differences and similarities in techniques and instrumentation. Int J Hyperthermia 2023; 40:2233720. [PMID: 37460101 PMCID: PMC10479943 DOI: 10.1080/02656736.2023.2233720] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 06/15/2023] [Accepted: 07/02/2023] [Indexed: 07/20/2023] Open
Abstract
Since its inception about two decades ago, histotripsy - a non-thermal mechanical tissue ablation technique - has evolved into a spectrum of methods, each with distinct potentiating physical mechanisms: intrinsic threshold histotripsy, shock-scattering histotripsy, hybrid histotripsy, and boiling histotripsy. All methods utilize short, high-amplitude pulses of focused ultrasound delivered at a low duty cycle, and all involve excitation of violent bubble activity and acoustic streaming at the focus to fractionate tissue down to the subcellular level. The main differences are in pulse duration, which spans microseconds to milliseconds, and ultrasound waveform shape and corresponding peak acoustic pressures required to achieve the desired type of bubble activity. In addition, most types of histotripsy rely on the presence of high-amplitude shocks that develop in the pressure profile at the focus due to nonlinear propagation effects. Those requirements, in turn, dictate aspects of the instrument design, both in terms of driving electronics, transducer dimensions and intensity limitations at surface, shape (primarily, the F-number) and frequency. The combination of the optimized instrumentation and the bio-effects from bubble activity and streaming on different tissues, lead to target clinical applications for each histotripsy method. Here, the differences and similarities in the physical mechanisms and resulting bioeffects of each method are reviewed and tied to optimal instrumentation and clinical applications.
Collapse
Affiliation(s)
- Randall P Williams
- Division of Gastroenterology, Department of Medicine, University of Washington, Seattle, WA, USA
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| | - Julianna C Simon
- Graduate Program in Acoustics, The Pennsylvania State University, University Park, PA, USA
| | - Vera A Khokhlova
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA
- Department of Acoustics, Physics Faculty, Moscow State University, Moscow, Russia
| | - Oleg A Sapozhnikov
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA
- Department of Acoustics, Physics Faculty, Moscow State University, Moscow, Russia
| | - Tatiana D Khokhlova
- Division of Gastroenterology, Department of Medicine, University of Washington, Seattle, WA, USA
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| |
Collapse
|
6
|
Zubair M, Adams MS, Diederich CJ. An endoluminal cylindrical sectored-ring ultrasound phased-array applicator for minimally-invasive therapeutic ultrasound. Med Phys 2023; 50:1-19. [PMID: 36413363 PMCID: PMC9870260 DOI: 10.1002/mp.16113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 11/10/2022] [Accepted: 11/10/2022] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND The size of catheter-based ultrasound devices for delivering ultrasound energy to deep-seated tumors is constrained by the access pathway which limits their therapeutic capabilities. PURPOSE To devise and investigate a deployable applicator suitable for minimally-invasive delivery of therapeutic ultrasound, consisting of a 2D cylindrical sectored-ring ultrasound phased array, integrated within an expandable paraboloid-shaped balloon-based reflector. The balloon can be collapsed for compact delivery and expanded close to the target position to mimic a larger-diameter concentric-ring sector-vortex array for enhanced dynamic control of focal depth and volume. METHODS Acoustic and biothermal simulations were employed in 3D generalized homogeneous and patient-specific heterogeneous models, for three-phased array transducers with 32, 64, and 128 elements, composed of sectored 4, 8, and 16 tubular ring transducers, respectively. The applicator performance was characterized as a function of array configuration, focal depth, phasing modes, and balloon reflector geometry. A 16-element proof-of-concept phased array applicator assembly, consisting of four tubular transducers each divided into four sectors, was fabricated, and characterized with hydrophone measurements along and across the axis, and ablations in ex vivo tissue. RESULTS Simulation results indicated that transducer arrays (1.5 MHz, 9 mm OD × 20 mm long), balloon sizes (41-50 mm expanded diameter, 20-60 mm focal depth), phasing mode (0-4) and sonication duration (30 s) can produce spatially localized acoustic intensity focal patterns (focal length: 3-22 mm, focal width: 0.7-8.7 mm) and ablative thermal lesions (width: 2.7-16 mm, length: 6-46 mm) in pancreatic tissue across a 10-90 mm focal depth range. Patient-specific studies indicated that 0.1, 0.46, and 1.2 cm3 volume of tumor can be ablated in the body of the pancreas for 120 s sonications using a single axial focus (Mode 0), or four, and eight simultaneous foci in a toroidal pattern (Mode 2 and 4, respectively). Hydrophone measurements demonstrated good agreement with simulation. Experiments in which chicken meat was thermally ablated indicated that volumetric ablation can be produced using single or multiple foci. CONCLUSIONS The results of this study demonstrated the feasibility of a novel compact ultrasound applicator design capable of focusing, deep penetration, electronic steering, and volumetric thermal ablation. The proposed applicator can be used for compact endoluminal or laparoscopic delivery of localized ultrasound energy to deep-seated targets.
Collapse
Affiliation(s)
- Muhammad Zubair
- Department of Radiation Oncology University of California San Francisco USA
| | - Matthew S. Adams
- Department of Radiation Oncology University of California San Francisco USA
| | - Chris J. Diederich
- Department of Radiation Oncology University of California San Francisco USA
| |
Collapse
|
7
|
Xu M, Xu D, Deng Z, Tian G, Jiang T. Long-term outcomes of endoscopic ultrasound-guided laser ablation for liver tumors in the caudate lobe: 5 years of experience. Scand J Gastroenterol 2022; 58:558-564. [PMID: 36415178 DOI: 10.1080/00365521.2022.2148833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
OBJECTIVES Liver tumor in the caudate lobe is challenging to treat, partly due to its deep location. Endoscopic ultrasound-guided laser ablation (EUS-LA) is a new attractive option for tumors in high-risk or difficult-to-reach locations. This prospective study investigated the long-term efficacy of EUS-LA for tumors in the caudate lobe, and factors that predict outcomes. METHODS From June 2016 to July 2021, twenty consecutive patients (aged 56.95 ± 10.06 years) with 25 caudate lobe tumors (15.64 ± 6.37 mm) underwent EUS-LA. Treatment outcomes were assessed and predictive factors were calculated via univariate and multivariate analyses. RESULTS Twenty-five tumors achieved complete ablation after the first or second session of EUS-LA. The treatment effectiveness was 100%. During a median follow up of 27 months (3-60), four tumors (16%) developed local tumor progression and 15 patients (75%) experienced intrahepatic distant recurrence. According to univariate and multivariate analyses, the significant prognostic factor of local tumor progression was tumor size >2 cm (p = 0.047). Significant prognostic factors of intrahepatic distant recurrence were: tumor number, alpha-fetoprotein level, and total bilirubin level (p = 0.020, 0.019, 0.010, respectively). No adverse events related to EUS-LA were observed. CONCLUSION EUS-LA is a viable, safe, and effective treatment option for patients with liver tumor in the caudate lobe. Tumor size >2 cm increases the risk of post-procedural local tumor progression. Intrahepatic tumor number, and pretreatment alpha-fetoprotein level and total bilirubin level are associated with intrahepatic distant recurrence. REGISTRATION Clinicaltrials.gov, ID: NCT02816944(June 29, 2016).
Collapse
Affiliation(s)
- Min Xu
- Department of Ultrasound Medicine, First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Danxia Xu
- Department of Ultrasound Medicine, First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Zhuang Deng
- Department of Ultrasound Medicine, First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Guo Tian
- Department of Ultrasound Medicine, First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Tian'an Jiang
- Department of Ultrasound Medicine, First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
8
|
Lambin T, Lafon C, Drainville RA, Pioche M, Prat F. Locoregional therapies and their effects on the tumoral microenvironment of pancreatic ductal adenocarcinoma. World J Gastroenterol 2022; 28:1288-1303. [PMID: 35645539 PMCID: PMC9099187 DOI: 10.3748/wjg.v28.i13.1288] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 02/10/2022] [Accepted: 02/27/2022] [Indexed: 02/06/2023] Open
Abstract
Pancreatic ductal adenocarcinoma (PDAC) is expected to become the second leading cause of death from cancer by 2030. Despite intensive research in the field of therapeutics, the 5-year overall survival is approximately 8%, with only 20% of patients eligible for surgery at the time of diagnosis. The tumoral microenvironment (TME) of the PDAC is one of the main causes for resistance to antitumoral treatments due to the presence of tumor vasculature, stroma, and a modified immune response. The TME of PDAC is characterized by high stiffness due to fibrosis, with hypo microvascular perfusion, along with an immunosuppressive environment that constitutes a barrier to effective antitumoral treatment. While systemic therapies often produce severe side effects that can alter patients' quality of life, locoregional therapies have gained attention since their action is localized to the pancreas and can thus alleviate some of the barriers to effective antitumoral treatment due to their physical effects. Local hyperthermia using radiofrequency ablation and radiation therapy - most commonly using a local high single dose - are the two main modalities holding promise for clinical efficacy. Recently, irreversible electroporation and focused ultrasound-derived cavitation have gained increasing attention. To date, most of the data are limited to preclinical studies, but ongoing clinical trials may help better define the role of these locoregional therapies in the management of PDAC patients.
Collapse
Affiliation(s)
- Thomas Lambin
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon 69003, France
- Department of Gastroenterology, Hospices Civils de Lyon, Edouard Herriot Hospital, Lyon 69008, France
| | - Cyril Lafon
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon 69003, France
| | | | - Mathieu Pioche
- Department of Gastroenterology, Hospices Civils de Lyon, Edouard Herriot Hospital, Lyon 69008, France
| | - Frédéric Prat
- Service d’Endoscopie Digestive, Hôpital Beaujon, Assistance Publique-Hôpitaux de Paris, Clichy 92110, France
- INSERM U1016, Institut Cochin, Université de Paris, Paris 75014, France
| |
Collapse
|
9
|
Dhar J, Samanta J. Role of therapeutic endoscopic ultrasound in gastrointestinal malignancy- current evidence and future directions. Clin J Gastroenterol 2022; 15:11-29. [PMID: 35028906 DOI: 10.1007/s12328-021-01559-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Accepted: 11/11/2021] [Indexed: 12/31/2022]
Abstract
Endoscopic ultrasound (EUS) has come a long way from a mere diagnostic tool to an advanced therapeutic modality. With the advent of better technologies and accessories, EUS has found ground in the management of gastrointestinal (GI) malignancies, not only for diagnosis but also for therapeutic purposes. EUS can tackle a host of conditions, including hepato-pancreatico-biliary malignancies. Advances and experience in various EUS-guided biliary drainage techniques have enabled the endosonologist to tackle biliary obstruction when conventional techniques of endoscopic retrograde cholangiopancreatography (ERCP) and/or percutaneous transhepatic biliary drainage (PTBD) fails. More and more emerging data not only establishes the safety of EUS-BD but also demonstrates superior efficacy over PTBD and sometimes even ERCP. Malignant gastric outlet obstruction can now be safely managed with EUS-guided gastroenterostomy. Starting from pain management in malignant tumors through celiac plexus neurolysis to various tumor ablative therapies, EUS has forged ahead over percutaneous treatment or surgical options in the management of GI malignancies. Additional data is now coming up on the prospects of EUS-guided immunotherapy and biological therapy for tumor management. The future of EUS therapeutics in the field of GI malignancies is bright. With increasing evidence, this modality becoming a key player in management of a host of complex clinical conditions arising out of GI malignancies is in the offing. This review focuses on elucidating the role of therapeutic EUS in the management of GI malignancies, a synopsis of various techniques, data on its safety and efficacy as well as future advancements in this domain.
Collapse
Affiliation(s)
- Jahnvi Dhar
- Department of Gastroenterology, Postgraduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Jayanta Samanta
- Department of Gastroenterology, Postgraduate Institute of Medical Education and Research, Chandigarh, 160012, India.
| |
Collapse
|
10
|
A state-of-the-art comprehensive review summarizing the emerging data on endoscopic ultrasound-guided liver diseases management. Eur J Gastroenterol Hepatol 2021; 33:e13-e20. [PMID: 32804852 DOI: 10.1097/meg.0000000000001893] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Liver diseases are among the most common diseases worldwide accounting for substantial morbidity and mortality. Most liver diseases necessitate radiological evaluation or accurate diagnosis and recently for management as well. In the last decade, the application of therapeutic endoscopic ultrasound (EUS) procedure has been increasingly utilized for the management of various liver diseases. In this comprehensive narrative review article, we provide systematic overview on EUS-guided therapeutic interventions in various liver diseases summarizing most updated data regarding technical success, outcomes and safety profiles. Overall, 35 articles have reported on the use of EUS in the treatment of liver diseases with excellent technical success, favorable radiological response and high safety profiles for EUS-guided treatment of solid and cystic liver lesion and for EUS-guided angiotherapy for gastric varices, except for EUS-guided cyanoacrylate glue injection which was associated with life-threatening fatal systemic embolization adverse events. This suggests that EUS-guided intervention is a new promising therapeutic intervention for the treatment of various liver diseases with durable effect and a limited potential for adverse events.
Collapse
|
11
|
Dhar J, Samanta J. Role of endoscopic ultrasound in the field of hepatology: Recent advances and future trends. World J Hepatol 2021; 13:1459-1483. [PMID: 34904024 PMCID: PMC8637671 DOI: 10.4254/wjh.v13.i11.1459] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 07/19/2021] [Accepted: 09/03/2021] [Indexed: 02/06/2023] Open
Abstract
The role of endoscopic ultrasound (EUS) as a diagnostic and therapeutic modality for the management of various gastrointestinal diseases has been expanding. The imaging or intervention for various liver diseases has primarily been the domain of radiologists. With the advances in EUS, the domain of endosonologists is rapidly expanding in the field of hepatology. The ability to combine endoscopy and sonography in one hybrid device is a unique property of EUS, together with the ability to bring its probe/transducer near the liver, the area of interest. Its excellent spatial resolution and ability to provide real-time images coupled with several enhancement techniques, such as contrast-enhanced (CE) EUS, have facilitated the growth of EUS. The concept of “Endo-hepatology” encompasses the wide range of diagnostic and therapeutic procedures that are now gradually becoming feasible for managing various liver diseases. Diagnostic advancements can enable a wide array of techniques from elastography and liver biopsy for liver parenchymal diseases, to CE-EUS for focal liver lesions to portal pressure measurements for managing various liver conditions. Similarly, therapeutic advancements range from EUS-guided eradication of varices, drainage of bilomas and abscesses to various EUS-guided modalities of liver tumor management. We provide a comprehensive review of all the different diagnostic and therapeutic EUS modalities available for the management of various liver diseases. A synopsis of all the technical details involving each procedure and the available data has been tabulated, and the future trends in this area have been highlighted.
Collapse
Affiliation(s)
- Jahnvi Dhar
- Department of Gastroenterology, Post Graduate Institute of Medical Education and Research, Chandigarh 160012, India
| | - Jayanta Samanta
- Department of Gastroenterology, Post Graduate Institute of Medical Education and Research, Chandigarh 160012, India
| |
Collapse
|
12
|
Stocker GE, Zhang M, Xu Z, Hall TL. Endocavity Histotripsy for Efficient Tissue Ablation-Transducer Design and Characterization. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2896-2905. [PMID: 33507869 PMCID: PMC8451243 DOI: 10.1109/tuffc.2021.3055138] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
A 34-mm aperture transducer was designed and tested for proof of concept to ablate tissues using an endocavity histotripsy device. Several materials and two drivers were modeled and tested to determine an effective piezoelectric-matching layer combination and driver design. The resulting transducer was fabricated using 1.5 MHz porous PZT and PerFORM 3-D printed acoustic lenses and was driven with a multicycle class-D amplifier. The lower frequency, compared to previously developed small form factor histotripsy transducers, was selected to allow for more efficient volume ablation of tissue. The transducer was characterized and tested by measuring pressure field maps in the axial and lateral planes and pressure output as a function of driving voltage. The axial and lateral full-width-half-maximums of the focus were found to be 6.1 and 1.1 mm, respectively. The transducer was estimated to generate 34.5-MPa peak negative focal pressure with a peak-to-peak driving voltage of 1345 V. Performance testing was done by ablating volumes of bovine liver tissues ( n = 3 ). The transducer was found to be capable of ablating tissues at its full working distance of 17 mm.
Collapse
|
13
|
Zubair M, Adams MS, Diederich CJ. Deployable ultrasound applicators for endoluminal delivery of volumetric hyperthermia. Int J Hyperthermia 2021; 38:1188-1204. [PMID: 34376103 DOI: 10.1080/02656736.2021.1936216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Abstract
PURPOSE To investigate the design of an endoluminal deployable ultrasound applicator for delivering volumetric hyperthermia to deep tissue sites as a possible adjunct to radiation and chemotherapy. METHOD This study considers an ultrasound applicator consisting of two tubular transducers situated at the end of a catheter assembly, encased within a distensible conical shaped balloon-based reflector that redirects acoustic energy distally into the tissue. The applicator assembly can be inserted endoluminally or laparoscopically in a compact form and expanded after delivery to the target site. Comprehensive acoustic and biothermal simulations and parametric studies were employed in generalized 3D and patient-specific pancreatic head and body tumor models to characterize the acoustic performance and evaluate heating capabilities of the applicator by investigating the device at a range of operating frequencies, tissue acoustic and thermal properties, transducer configurations, power modulation, applicator positioning, and by analyzing the resultant 40, 41, and 43 °C isothermal volumes and penetration depth of the heating volume. Intensity distributions and volumetric temperature contours were calculated to define moderate hyperthermia boundaries. RESULTS Parametric studies demonstrated the frequency selection to control volume and depth of therapeutic heating from 62 to 22 cm3 and 4 to 2.6 cm as frequency ranges from 1 MHz to 4.7 MHz, respectively. Width of the heating profile tracks closely with the aperture. Water cooling within the reflector balloon was effective in controlling temperature to 37 °C maximum within the luminal wall. Patient-specific studies indicated that applicators with extended OD in the range of 3.6-6.2 cm with 0.5-1 cm long and 1 cm OD transducers can heat volumes of 1.1-7 cm3, 3-26 cm3, and 3.3-37.4 cm3 of pancreatic body and head tumors above 43, 41, and 40 °C, respectively. CONCLUSION In silico studies demonstrated the feasibility of combining endoluminal ultrasound with an integrated expandable balloon reflector for delivering volumetric hyperthermia in regions adjacent to body lumens and cavities.
Collapse
Affiliation(s)
- Muhammad Zubair
- Thermal Therapy Research Group, Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, USA
| | - Matthew S Adams
- Thermal Therapy Research Group, Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, USA
| | - Chris J Diederich
- Thermal Therapy Research Group, Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, USA
| |
Collapse
|
14
|
DeWitt JM, Arain M, Chang KJ, Sharaiha R, Komanduri S, Muthusamy VR, Hwang JH. Interventional Endoscopic Ultrasound: Current Status and Future Directions. Clin Gastroenterol Hepatol 2021; 19:24-40. [PMID: 32950747 DOI: 10.1016/j.cgh.2020.09.029] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 09/11/2020] [Accepted: 09/15/2020] [Indexed: 02/06/2023]
Abstract
The evolution of endoscopic ultrasound (EUS) from a diagnostic to a therapeutic procedure has resulted in a paradigm shift toward endoscopic management of disease states that previously required percutaneous or surgical approaches. The past few years have seen additional techniques and devices that have enabled endoscopists to expand its diagnostic and therapeutic capabilities. Some of these techniques initially were reported more than a decade ago; however, with further device development and refinement in techniques there is potential for expanding the application of these techniques and new technologies to a broader group of interventional gastroenterologists. Lack of formalized training, devices, and prospective data regarding their use in addition to a scarcity of guidelines on implementation of these technologies into clinical practice are contributing factors impeding the growth of the field of interventional EUS. In April 2019, the American Gastroenterological Association's Center for Gastrointestinal Innovation and Technology conducted its annual Tech Summit and a key session focused on interventional EUS. This article is a White Paper generated from the conference, discusses the published literature pertaining to the topic of interventional EUS, and outlines a proposed framework for the implementation of interventional EUS techniques into clinical practice. Three primary areas of interventional EUS are addressed: (1) EUS-guided access; (2) EUS-guided tumor ablation; and (3) endohepatology. There was general agreement among participants on several key components. The introduction of these novel interventions requires better tools, more data on safety/outcomes, and improved training for endoscopists. Participants also agreed that widespread implementation and use of these techniques will require support from Gastrointestinal Societies and other key stakeholders including payers. Continued work by the Gastrointestinal Societies and manufacturers to provide training programs, appropriate equipment/work environments, and policies that motivate endoscopists to adopt new techniques is essential for growing the field of interventional EUS.
Collapse
Affiliation(s)
- John M DeWitt
- Department of Gastroenterology and Hepatology, Indiana University Medical Center, Indianapolis, Indiana
| | - Mustafa Arain
- Division of Gastroenterology, University of California, San Francisco, San Francisco, California
| | - Kenneth J Chang
- H. H. Chao Comprehensive Digestive Disease Center, Division of Gastroenterology and Hepatology, Department of Medicine, University of California, Irvine, California
| | - Reem Sharaiha
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Weill Cornell Medicine, New York, New York
| | - Sri Komanduri
- Department of Gastroenterology and Hepatology, Northwestern University, Chicago, Illinois
| | - V Raman Muthusamy
- Vatche and Tamar Manoukian Division of Digestive Diseases, Department of Medicine, University of California, Los Angeles, Los Angeles, California
| | - Joo Ha Hwang
- Division of Gastroenterology and Hepatology, Department of Medicine, Stanford University, Stanford, California.
| | | |
Collapse
|
15
|
Hashimoto R, Chang KJ. Endoscopic ultrasound guided hepatic interventions. Dig Endosc 2021; 33:54-65. [PMID: 32145117 DOI: 10.1111/den.13661] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2019] [Accepted: 03/03/2020] [Indexed: 02/08/2023]
Abstract
Intervention for liver disease has predominantly been performed through the percutaneous approach. However, as endoscopic ultrasound (EUS) applications have expanded, there have emerged various EUS-guided interventions for liver disease, a space we call "Endo-Hepatology". EUS-guided liver biopsy can be considered the "forerunner" of Endo-Hepatology and has become a clinical option for patients requiring histologic diagnosis and staging of their liver disease. EUS also enables direct access to the portal vein. Subsequently, many procedures are being explored, such as angiography, measurement of the portosystemic pressure gradient, portal vein sampling to detect cancer cell or DNA, and EUS-guided transhepatic intrahepatic portosystemic shunt creation. Since the transducer is close to the liver, especially the left and caudate lobes, EUS can be used as a rescue when the percutaneous approach is not favorable and EUS-guided treatments of liver tumor, cyst and abscess have been reported. This review summarizes the available studies of EUS-guided intervention in the liver.
Collapse
Affiliation(s)
- Rintaro Hashimoto
- H. H. Chao Comprehensive Digestive Center, University of California Irvine Medical Center, Orange, USA
| | - Kenneth J Chang
- H. H. Chao Comprehensive Digestive Center, University of California Irvine Medical Center, Orange, USA
| |
Collapse
|
16
|
Sbeit W, Kadah A, Mari A, Mahamid M, Khoury T. A Comprehensive Narrative Review on the Evolving Role of Endoscopic Ultrasound in Focal Solid Liver Lesions Diagnosis and Management. Diagnostics (Basel) 2020; 10:688. [PMID: 32932960 PMCID: PMC7554970 DOI: 10.3390/diagnostics10090688] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 09/05/2020] [Accepted: 09/10/2020] [Indexed: 12/11/2022] Open
Abstract
The implications of endoscopic ultrasound (EUS) have expanded considerably in recent years to cover more fields in invasive gastroenterology practice, as both an investigative and therapeutic modality. The utility of EUS in the diagnosis and management of focal liver lesions has gained a special attractiveness recently. The EUS probe proximity to the liver and its excellent spatial resolution enables real-time images coupled with several enhancement techniques, such as contrast-enhanced (CE) EUS. Aside from its notable capability to execute targeted biopsies and therapeutic interventions, EUS has developed into a hopeful therapeutic tool for the management of solid liver lesions. Herein, we provide a comprehensive state-of-the-art review on the efficacy and safety of EUS in the diagnosis and management of focal solid liver lesions. Medline/PubMed and Embase database searches were conducted by two separate authors (T.K. and W.S.), all relevant studies were assessed, and relevant data was extracted and fully reported. EUS-guided diagnosis of focal liver lesions by sonographic morphologic appearance and cytological and histopathological finding of biopsies obtained via fine needle aspiration/biopsy have been shown to significantly improve the diagnosis of solid liver lesions compared with traditional imaging tools. Similarly, EUS-guided treatment has been shown to consistently have excellent technical success, high efficacy, and minor adverse events. The evolving valuable evidences of EUS utility might satisfy the unmet need of optimizing management of focal solid liver lesions.
Collapse
Affiliation(s)
- Wisam Sbeit
- Department of Gastroenterology, Galilee Medical Center, Nahariya 22100, Israel; (W.S.); (A.K.)
- Faculty of Medicine in the Galilee, Bar-Ilan University, Safed 1311502, Israel;
| | - Anas Kadah
- Department of Gastroenterology, Galilee Medical Center, Nahariya 22100, Israel; (W.S.); (A.K.)
- Faculty of Medicine in the Galilee, Bar-Ilan University, Safed 1311502, Israel;
| | - Amir Mari
- Faculty of Medicine in the Galilee, Bar-Ilan University, Safed 1311502, Israel;
- Gastroenterology and Endoscopy Units, The Nazareth Hospital, EMMS, Nazareth 16100, Israel
| | - Mahmud Mahamid
- Department of Gastroenterology and Liver Diseases, Shaare Zedek Medical Center, Jerusalem 9103102, Israel;
- Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem 9112102, Israel
| | - Tawfik Khoury
- Department of Gastroenterology, Galilee Medical Center, Nahariya 22100, Israel; (W.S.); (A.K.)
- Faculty of Medicine in the Galilee, Bar-Ilan University, Safed 1311502, Israel;
| |
Collapse
|
17
|
Sebeke LC, Rademann P, Maul AC, Schubert-Quecke C, Annecke T, Yeo SY, Castillo-Gómez JD, Schmidt P, Grüll H, Heijman E. Feasibility study of MR-guided pancreas ablation using high-intensity focused ultrasound in a healthy swine model. Int J Hyperthermia 2020; 37:786-798. [PMID: 32619373 DOI: 10.1080/02656736.2020.1782999] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Purpose: Pancreatic cancer is typically diagnosed in a late stage with limited therapeutic options. For those patients, ultrasound-guided high-intensity focused ultrasound (US-HIFU) can improve local control and alleviate pain. However, MRI-guided HIFU (MR-HIFU) has not yet been studied extensively in this context. To facilitate related research and accelerate clinical translation, we report a workflow for the in vivo HIFU ablation of the porcine pancreas under MRI guidance.Materials and methods: The pancreases of five healthy German landrace pigs (35-58 kg) were sonicated using a clinical MR-HIFU system. Acoustic access to the pancreas was supported by a specialized diet and a hydrogel compression device for bowel displacement. Organ motion was suspended using periods of apnea. The size of the resulting thermal lesions was assessed using the thermal threshold- and dose profiles, non-perfused volume, and gross examination. The effect of the compression device on beam path length was assessed using MRI imaging.Results: Eight of ten treatments resulted in clearly visible damage in the target tissue upon gross examination. Five treatments resulted in coagulative necrosis. Good agreement between the four metrics for lesion size and a clear correlation between the delivered energy dose and the resulting lesion size were found. The compression device notably shortened the intra-abdominal beam path.Conclusions: We demonstrated a workflow for HIFU treatment of the porcine pancreas in-vivo under MRI-guidance. This development bears significance for the development of MR-guided HIFU interventions on the pancreas as the pig is the preferred animal model for the translation of pre-clinical research into clinical application.
Collapse
Affiliation(s)
- Lukas Christian Sebeke
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.,Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
| | - Pia Rademann
- Experimental Medicine, University of Cologne, Faculty of Medicine and University Hospital of Cologne, Cologne, Germany
| | - Alexandra Claudia Maul
- Experimental Medicine, University of Cologne, Faculty of Medicine and University Hospital of Cologne, Cologne, Germany
| | - Claudia Schubert-Quecke
- Experimental Medicine, University of Cologne, Faculty of Medicine and University Hospital of Cologne, Cologne, Germany
| | - Thorsten Annecke
- Department of Anesthesiology and Intensive Care Medicine, University of Cologne, Faculty of Medicine and University Hospital of Cologne, Cologne, Germany
| | - Sin Yuin Yeo
- Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany.,Profound Medical GmbH, Hamburg, Germany
| | - Juan Daniel Castillo-Gómez
- Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
| | - Patrick Schmidt
- Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
| | - Holger Grüll
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.,Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
| | - Edwin Heijman
- Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany.,Philips Research Eindhoven, High Tech, Eindhoven, The Netherlands
| |
Collapse
|
18
|
Kim H, Wu H, Cho N, Zhong P, Mahmood K, Lyerly HK, Jiang X. Miniaturized Intracavitary Forward-Looking Ultrasound Transducer for Tissue Ablation. IEEE Trans Biomed Eng 2019; 67:2084-2093. [PMID: 31765299 DOI: 10.1109/tbme.2019.2954524] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
OBJECTIVE This paper aims to develop a miniaturized forward-looking ultrasound transducer for intracavitary tissue ablation, which can be used through an endoscopic device. The internal ultrasound (US) delivery is capable of directly interacting with the target tumor, resolving adverse issues of currently available US devices, such as unintended tissue damage and insufficient delivery of acoustic power. METHODS To transmit a high acoustic pressure from a small aperture (<3 mm), a double layer transducer (1.3 MHz) was designed and fabricated based on numerical simulations. The electric impedance and the acoustic pressure of the actual device was characterized with an impedance analyzer and a hydrophone. Ex vivo tissue ablation tests and temperature monitoring were then conducted with porcine livers. RESULTS The acoustic intensity of the transducer was 37.1 W/cm2 under 250 Vpp and 20% duty cycle. The tissue temperature was elevated to 51.8 °C with a 67 Hz pulse-repetition frequency. The temperature profile in the tissue indicated that ultrasound energy was effectively absorbed inside the tissue. During a 5-min sonification, an approximate tissue volume of 2.5 × 2.5 × 1.0 mm3 was ablated, resulting in an irreversible lesion. CONCLUSION This miniaturized US transducer is a promising medical option for the precise tissue ablation, which can reduce the risk of unintended tissue damage found in noninvasive US treatments. SIGNIFICANCE Having a small aperture (2 mm), the intracavitary device is capable of ablating a bio tissue in 5 min with a relatively low electric power (<17 W).
Collapse
|
19
|
Campos S, Poley JW, van Driel L, Bruno MJ. The role of EUS in diagnosis and treatment of liver disorders. Endosc Int Open 2019; 7:E1262-E1275. [PMID: 31579708 PMCID: PMC6773586 DOI: 10.1055/a-0958-2183] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Accepted: 01/07/2019] [Indexed: 02/06/2023] Open
Abstract
Background and aim Transabdominal ultrasound (US), computed tomographic scanning (CT) and magnetic resonance imaging (MRI) are established diagnostic tools for liver diseases. Percutaneous transhepatic cholangiography is used to perform hepatic interventional procedures including biopsy, biliary drainage procedures, and radiofrequency ablation. Despite their widespread use, these techniques have limitations. Endoscopic ultrasound (EUS), a tool that has proven useful for evaluating the mediastinum, esophagus, stomach, pancreas, and biliary tract, has an expanding role in the field of hepatology complementing the traditional investigational modalities. This review aimed to assess the current scientific evidence regarding diagnostic and therapeutic applications of EUS for hepatic diseases.
Collapse
Affiliation(s)
- Sara Campos
- Department of Gastroenterology, Hospital Garcia da Orta, Portugal
- Department of Gastroenterology and Hepatology, Erasmus MC, The Netherlands
| | - Jan-Werner Poley
- Department of Gastroenterology and Hepatology, Erasmus MC, The Netherlands
| | - Lydi van Driel
- Department of Gastroenterology and Hepatology, Erasmus MC, The Netherlands
| | - Marco J. Bruno
- Department of Gastroenterology and Hepatology, Erasmus MC, The Netherlands
| |
Collapse
|
20
|
Liu X, Ellens N, Williams E, Burdette EC, Karmarkar P, Weiss CR, Kraitchman D, Bottomley PA. High-resolution intravascular MRI-guided perivascular ultrasound ablation. Magn Reson Med 2019; 83:240-253. [PMID: 31402512 DOI: 10.1002/mrm.27932] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Revised: 06/24/2019] [Accepted: 07/15/2019] [Indexed: 12/22/2022]
Abstract
PURPOSE To develop and test in animal studies ex vivo and in vivo, an intravascular (IV) MRI-guided high-intensity focused ultrasound (HIFU) ablation method for targeting perivascular pathology with minimal injury to the vessel wall. METHODS IV-MRI antennas were combined with 2- to 4-mm diameter water-cooled IV-ultrasound ablation catheters for IV-MRI on a 3T clinical MRI scanner. A software interface was developed for monitoring thermal dose with real-time MRI thermometry, and an MRI-guided ablation protocol developed by repeat testing on muscle and liver tissue ex vivo. MRI thermal dose was measured as cumulative equivalent minutes at 43°C (CEM43 ). The IV-MRI IV-HIFU protocol was then tested by targeting perivascular ablations from the inferior vena cava of 2 pigs in vivo. Thermal dose and lesions were compared by gross and histological examination. RESULTS Ex vivo experiments yielded a 6-min ablation protocol with the IV-ultrasound catheter coolant at 3-4°C, a 30 mL/min flow rate, and 7 W ablation power. In 8 experiments, 5- to 10-mm thick thermal lesions of area 0.5-2 cm2 were produced that spared 1- to 2-mm margins of tissue abutting the catheters. The radial depths, areas, and preserved margins of ablation lesions measured from gross histology were highly correlated (r ≥ 0.79) with those measured from the CEM43 = 340 necrosis threshold determined by MRI thermometry. The psoas muscle was successfully targeted in the 2 live pigs, with the resulting ablations controlled under IV-MRI guidance. CONCLUSION IV-MRI-guided, IV-HIFU has potential as a precision treatment option that could preserve critical blood vessel wall during ablation of nonresectable perivascular tumors or other pathologies.
Collapse
Affiliation(s)
- Xiaoyang Liu
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, Maryland.,Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| | - Nicholas Ellens
- Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, Maryland.,Acertara Acoustic Laboratories, Longmont, Colorado
| | | | | | - Parag Karmarkar
- Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| | - Clifford R Weiss
- Division of Interventional Radiology, Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| | - Dara Kraitchman
- Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| | - Paul A Bottomley
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, Maryland.,Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| |
Collapse
|
21
|
Adams MS, Diederich CJ. Deployable cylindrical phased-array applicator mimicking a concentric-ring configuration for minimally-invasive delivery of therapeutic ultrasound. Phys Med Biol 2019; 64:125001. [PMID: 31108478 DOI: 10.1088/1361-6560/ab2318] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
A novel design for a deployable catheter-based ultrasound applicator for endoluminal and laparoscopic intervention is introduced. By combining a 1D cylindrical ring phased array with an expandable paraboloid or conical-shaped balloon-based reflector, the applicator can be controllably collapsed for compact delivery and deployed to mimic a forward-firing larger diameter concentric ring array with tight focusing and electronic steering capabilities in depth. Comprehensive acoustic and biothermal parametric studies were employed to characterize the capabilities of the applicator design as a function of transducer dimensions, phased array configuration, and balloon reflector geometry. Modeling results indicate that practical balloon sizes (43-57 mm expanded diameter), transducer array configurations (e.g. 1.5 MHz, 10 mm OD × 20 mm length, 8 or 16 array elements), and sonication durations (30 s) are capable of producing spatially-localized acoustic intensity focal patterns and ablative thermal lesions (width: 2.8-4.8 mm; length: 5.3-40.1 mm) in generalized soft tissue across a 5-100 mm depth range. Larger focal intensity gain magnitudes and narrower focal dimensions are attainable using paraboloid-shaped balloon reflectors with natural geometric focal depths of 25-55 mm, whereas conical-shaped reflectors (angled 45-55°) produce broader foci and extend electronic steering range in depth. A proof-of-concept phased array applicator assembly was fabricated and characterized using hydrophone and radiation force balance measurements and demonstrated good agreement with simulation. The results of this study suggest that combining small diameter cylindrical phased arrays with expandable balloon reflectors can enhance minimally invasive ultrasound-based intervention by augmenting achievable focal gains and penetration depths with dynamic adjustment of treatment depth.
Collapse
|
22
|
Saccomandi P, Lapergola A, Longo F, Schena E, Quero G. Thermal ablation of pancreatic cancer: A systematic literature review of clinical practice and pre-clinical studies. Int J Hyperthermia 2018; 35:398-418. [PMID: 30428728 DOI: 10.1080/02656736.2018.1506165] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
PURPOSE Pancreatic cancer is a challenging malignancy with low treatment option and poor life expectancy. Thermal ablation techniques were proposed as alternative treatment options, especially in advanced stages and for unfit-for-surgery patients. This systematic review describes the thermal ablative techniques -i.e., Laser (LA), Radiofrequency (RFA), Microwave (MWA) Ablation, High-Intensity Focused Ultrasound (HIFU) and cryoablation- available for pancreatic cancer treatment. Additionally, an analysis of the efficacy, complication rate and overall survival for each technique is conducted. MATERIAL AND METHODS This review collects the ex vivo, preclinical and clinical studies presenting the use of thermal techniques in the pancreatic cancer treatment, searched up to March 2018 in PubMed and Medline. Abstracts, letters-to-the-editor, expert opinions, reviews and non-English language manuscripts were excluded. RESULTS Sixty-five papers were included. For the ex vivo and preclinical studies, there are: 12 records for LA, 8 for RFA, 0 for MWA, 6 for HIFU, 1 for cryoablation and 3 for hybrid techniques. For clinical studies, 1 paper for LA, 14 for RFA, 1 for MWA, 17 for HIFU, 1 for cryoablation and 1 for hybrid techniques. CONCLUSIONS Important technological advances are presented in ex vivo and preclinical studies, as the real-time thermometry, nanotechnology and hybrid techniques to enhance the thermal outcome. Conversely, a lack of standardization in the clinical employment of the procedures emerged, leading to contrasting results on the safety and feasibility of some analyzed techniques. Uniform conclusions on the safety and feasibility of these techniques for pancreatic cancer will require further structured investigation.
Collapse
Affiliation(s)
- Paola Saccomandi
- a IHU-Strasbourg Institute of Image-Guided Surgery , Strasbourg , France.,b Departement of Mechanical Engineering, Politecnico di Milano , Milan , Italy
| | - Alfonso Lapergola
- a IHU-Strasbourg Institute of Image-Guided Surgery , Strasbourg , France.,c Università G. D'Annunzio , Chieti , Italy
| | - Fabio Longo
- a IHU-Strasbourg Institute of Image-Guided Surgery , Strasbourg , France.,d Fondazione Policlinico Universitario Agostino Gemelli IRCCS , Rome , Italy
| | | | - Giuseppe Quero
- d Fondazione Policlinico Universitario Agostino Gemelli IRCCS , Rome , Italy
| |
Collapse
|
23
|
Lundt J, Hall T, Rao A, Fowlkes JB, Cain C, Lee F, Xu Z. Coalescence of residual histotripsy cavitation nuclei using low-gain regions of the therapy beam during electronic focal steering. Phys Med Biol 2018; 63:225010. [PMID: 30418936 DOI: 10.1088/1361-6560/aaeaf3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Following collapse of a histotripsy cloud, residual microbubbles may persist for seconds, distributed throughout the focus. Their presence can attenuate and scatter subsequent pulses, hindering treatment speed and homogeneity. Previous studies have demonstrated use of separate low-amplitude (~1 MPa) pulses interleaved with histotripsy pulses to drive bubble coalescence (BC), significantly improving treatment speed without sacrificing homogeneity. We propose that by using electronic focal steering (EFS) to direct the therapy focus throughout specially-designed EFS sequences, it is possible to use low-gain regions of the therapy beam to accomplish BC during EFS without any additional acoustic sequence. First, to establish proof of principle for an isolated focus, a 50-foci EFS sequence was constructed with the first position isolated near the geometric focus and remaining positions distributed post-focally. EFS sequences were evaluated in tissue-mimicking phantoms with gas concentrations of 20% and 100% with respect to saturation. Results using an isolated focus demonstrated that at 20% gas concentration, 49 EFS pulses were sufficient to achieve BC in all samples for pulse repetition frequency (PRF) ⩽ 800 Hz and 84.1% ± 3.0% of samples at 5 kHz PRF. For phantoms prepared with 100% gas concentration, BC was achieved by 49 EFS pulses in 39.2% ± 4.7% of samples at 50 Hz PRF and 63.4% ± 15.3% of samples at 5 kHz. To show feasibility of using the EFS-BC method to ablate a large volume quickly, a 1000-foci EFS sequence covering a volume of approximately 27 ml was tested. Results indicate that the BC effect was similarly present. A treatment rate of 27 ± 6 ml min-1 was achieved, which is signficantly faster than standard histotripsy and ultrasound thermal ablation. This study demonstrates that histotripsy with EFS can achieve BC without employing a separate acoustic sequence which has the potential to accelerate large-volume ablation while minimizing energy deposition.
Collapse
Affiliation(s)
- Jonathan Lundt
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States of America
| | | | | | | | | | | | | |
Collapse
|
24
|
Lee LS, Andersen DK, Ashida R, Brugge WR, Canto MI, Chang KJ, Chari ST, DeWitt J, Hwang JH, Khashab MA, Kim K, Levy MJ, McGrath K, Park WG, Singhi A, Stevens T, Thompson CC, Topazian MD, Wallace MB, Wani S, Waxman I, Yadav D, Singh VK. EUS and related technologies for the diagnosis and treatment of pancreatic disease: research gaps and opportunities-Summary of a National Institute of Diabetes and Digestive and Kidney Diseases workshop. Gastrointest Endosc 2017; 86:768-778. [PMID: 28941651 PMCID: PMC6698378 DOI: 10.1016/j.gie.2017.08.006] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2017] [Accepted: 08/07/2017] [Indexed: 12/11/2022]
Abstract
A workshop was sponsored by the National Institute of Diabetes and Digestive and Kidney Diseases to address the research gaps and opportunities in pancreatic EUS. The event occurred on July 26, 2017 in 4 sessions: (1) benign pancreatic diseases, (2) high-risk pancreatic diseases, (3) diagnostic and therapeutics, and (4) new technologies. The current state of knowledge was reviewed, with identification of numerous gaps in knowledge and research needs. Common themes included the need for large multicenter consortia of various pancreatic diseases to facilitate meaningful research of these entities; to standardize EUS features of different pancreatic disorders, the technique of sampling pancreatic lesions, and the performance of various therapeutic EUS procedures; and to identify high-risk disease early at the cellular level before macroscopic disease develops. The need for specialized tools and accessories to enable the safe and effective performance of therapeutic EUS procedures also was discussed.
Collapse
Affiliation(s)
- Linda S Lee
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | - Dana K Andersen
- Division of Digestive Diseases and Nutrition, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, Maryland, USA
| | - Reiko Ashida
- Departments of Cancer Survey and Gastrointestinal Oncology, Osaka Prefectural Hospital Organization, Osaka International Cancer Institute, Osaka, Japan
| | - William R Brugge
- Department of Gastroenterology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Mimi I Canto
- Division of Gastroenterology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Kenneth J Chang
- Comprehensive Digestive Disease Center, Department of Gastroenterology and Hepatology, University of California at Irvine Health, Orange, California, USA
| | - Suresh T Chari
- Department of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA
| | - John DeWitt
- Division of Gastroenterology, Indiana University Health Medical Center, Indianapolis, Indiana, USA
| | - Joo Ha Hwang
- Department of Medicine, University of Washington, Seattle, Washington, USA
| | - Mouen A Khashab
- Division of Gastroenterology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Kang Kim
- Department of Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Michael J Levy
- Department of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA
| | - Kevin McGrath
- Division of Gastroenterology, Hepatology, and Nutrition, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Walter G Park
- Department of Medicine, Stanford University School of Medicine, Stanford, California, USA
| | - Aatur Singhi
- Department of Pathology, University of Pittsburgh Medical Center, Sewickley, Pennsylvania, USA
| | - Tyler Stevens
- Department of Gastroenterology, Cleveland Clinic, Cleveland, Ohio, USA
| | - Christopher C Thompson
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | - Mark D Topazian
- Department of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA
| | - Michael B Wallace
- Department of Gastroenterology and Hepatology, Mayo Clinic Florida, Jacksonville, Florida, USA
| | - Sachin Wani
- Division of Gastroenterology and Hepatology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Irving Waxman
- Department of Medicine, The University of Chicago Comprehensive Cancer Center, University of Chicago School of Medicine, Chicago, Illinois, USA
| | - Dhiraj Yadav
- Department of Medicine, Stanford University School of Medicine, Stanford, California, USA
| | - Vikesh K Singh
- Division of Gastroenterology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| |
Collapse
|
25
|
Adams MS, Salgaonkar VA, Scott SJ, Sommer G, Diederich CJ. Integration of deployable fluid lenses and reflectors with endoluminal therapeutic ultrasound applicators: Preliminary investigations of enhanced penetration depth and focal gain. Med Phys 2017; 44:5339-5356. [PMID: 28681404 DOI: 10.1002/mp.12458] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Revised: 06/19/2017] [Accepted: 07/02/2017] [Indexed: 02/06/2023] Open
Abstract
PURPOSE Catheter-based ultrasound applicators can generate thermal ablation of tissues adjacent to body lumens, but have limited focusing and penetration capabilities due to the small profile of integrated transducers required for the applicator to traverse anatomical passages. This study investigates a design for an endoluminal or laparoscopic ultrasound applicator with deployable acoustic reflector and fluid lens components, which can be expanded after device delivery to increase the effective acoustic aperture and allow for deeper and dynamically adjustable target depths. Acoustic and biothermal theoretical studies, along with benchtop proof-of-concept measurements, were performed to investigate the proposed design. METHODS The design schema consists of an array of tubular transducer(s) situated at the end of a catheter assembly, surrounded by an expandable water-filled conical balloon with a secondary reflective compartment that redirects acoustic energy distally through a plano-convex fluid lens. By controlling the lens fluid volume, the convex surface can be altered to adjust the focal length or collapsed for device insertion or removal. Acoustic output of the expanded applicator assembly was modeled using the rectangular radiator method and secondary sources, accounting for reflection and refraction at interfaces. Parametric studies of transducer radius (1-5 mm), height (3-25 mm), frequency (1.5-3 MHz), expanded balloon diameter (10-50 mm), lens focal length (10-100 mm), lens fluid (silicone oil, perfluorocarbon), and tissue attenuation (0-10 Np/m/MHz) on beam distributions and focal gain were performed. A proof-of-concept applicator assembly was fabricated and characterized using hydrophone-based intensity profile measurements. Biothermal simulations of endoluminal ablation in liver and pancreatic tissue were performed for target depths between 2 and 10 cm. RESULTS Simulations indicate that focal gain and penetration depth scale with the expanded reflector-lens balloon diameter, with greater achievable performance using perfluorocarbon lens fluid. Simulations of a 50 mm balloon OD, 10 mm transducer outer diameter (OD), 1.5 MHz assembly in water resulted in maximum intensity gain of ~170 (focal dimensions: ~12 mm length × 1.4 mm width) at ~5 cm focal depth and focal gains above 100 between 24 and 84 mm depths. A smaller (10 mm balloon OD, 4 mm transducer OD, 1.5 MHz) configuration produced a maximum gain of 6 at 9 mm depth. Compared to a conventional applicator with a fixed spherically focused transducer of 12 mm diameter, focal gain was enhanced at depths beyond 20 mm for assembly configurations with balloon diameters ≥ 20 mm. Hydrophone characterizations of the experimental assembly (31 mm reflector/lens diameter, 4.75 mm transducer radius, 1.7 MHz) illustrated focusing at variable depths between 10-70 mm with a maximum gain of ~60 and demonstrated agreement with theoretical simulations. Biothermal simulations (30 s sonication, 75 °C maximum) indicate that investigated applicator assembly configurations, at 30 mm and 50 mm balloon diameters, could create localized ellipsoidal thermal lesions increasing in size from 10 to 55 mm length × 3-6 mm width in liver tissue as target depth increased from 2 to 10 cm. CONCLUSIONS Preliminary theoretical and experimental analysis demonstrates that combining endoluminal ultrasound with an expandable acoustic reflector and fluid lens assembly can significantly enhance acoustic focal gain and penetration from inherently smaller diameter catheter-based applicators.
Collapse
Affiliation(s)
- Matthew S Adams
- Thermal Therapy Research Group, University of California San Francisco, 2340 Sutter Street, S341, San Francisco, CA, 94115, USA.,University of California, Berkeley - University of California, San Francisco Graduate Program in Bioengineering, University of California, CA, USA
| | - Vasant A Salgaonkar
- Thermal Therapy Research Group, University of California San Francisco, 2340 Sutter Street, S341, San Francisco, CA, 94115, USA
| | - Serena J Scott
- Thermal Therapy Research Group, University of California San Francisco, 2340 Sutter Street, S341, San Francisco, CA, 94115, USA
| | - Graham Sommer
- Department of Radiology, Stanford University, Stanford, CA, 94305, USA
| | - Chris J Diederich
- Thermal Therapy Research Group, University of California San Francisco, 2340 Sutter Street, S341, San Francisco, CA, 94115, USA.,University of California, Berkeley - University of California, San Francisco Graduate Program in Bioengineering, University of California, CA, USA
| |
Collapse
|
26
|
The Emerging Role of Endoscopists in Treating Unresectable Pancreatic Cancer. Pancreas 2017; 46:839-849. [PMID: 28697122 DOI: 10.1097/mpa.0000000000000862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
Pancreatic adenocarcinoma is the eighth leading cause of cancer deaths worldwide in men and ninth leading cause in women. Surgical resection offers the only chance of potential cure; however, only 9.4% of patients present at the localized, resectable stage, whereas the rest present at the locally advanced or metastatic, unresectable stages. Because of the guarded outcomes following systemic chemoradiation and the associated systemic toxicities, locoregional therapies have recently gained popularity. Various endoscopic techniques (endoscopic ultrasound [EUS]-guided ablative therapies, fine-needle instillation of antitumor agents, stereotactic body radiation therapy with EUS-guided fiducial marker placement, and EUS-guided brachytherapy) have been explored over the past several years. Endoscopic therapy plays a role in the treatment of unresectable pancreatic adenocarcinoma. Its minimal invasiveness and increased precision of delivering oncologic treatments under EUS guidance render it as a favorable option for patients who do not benefit from surgical resection. New endoscopic therapies are currently under investigation, and the emerging role of the endoscopist in the treatment of unresectable pancreatic cancer continues to grow.
Collapse
|
27
|
Farhanieh O, Sahafi A, Bardhan Roy R, Ergun AS, Bozkurt A. Integrated HIFU Drive System on a Chip for CMUT-Based Catheter Ablation System. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2017; 11:534-546. [PMID: 28333640 DOI: 10.1109/tbcas.2017.2649942] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Conventional High Intensity Focused Ultrasound (HIFU) is a therapeutic modality which is extracorporeally administered. In applications where a relatively small HIFU lesion is required, an intravascular HIFU probe can be deployed to the ablation site. In this paper, we demonstrate the design and implementation a fully integrated HIFU drive system on a chip to be placed on a 6 Fr catheter probe. An 8-element capacitive micromachined ultrasound transducer (CMUT) ring array of 2 mm diameter has been used as the ultrasound source. The driver chip is fabricated in 0.35 μm AMS high-voltage CMOS technology and comprises eight continuous-wave (CW) high-voltage CMUT drivers (10.9 ns and 9.4 ns rise and fall times at 20 V pp output into a 15 pF), an eight-channel digital beamformer (8-12 MHz output frequency with 11.25 ° phase accuracy) and a phase locked loop with an integrated VCO as a tunable clock source (128-192 MHz). The chip occupies 1.85 × 1.8 mm 2 area including input and output (I/O) pads. When the transducer array is immersed in sunflower oil and driven by the IC with eight 20 Vpp CW pulses at 10 MHz, real-time thermal images of the HIFU beam indicate that the focal temperature rises by 16.8 °C in 11 seconds. Each HV driver consumes around 67 mW of power when driving the CMUT array at 10 MHz, which adds up to 560 mW for the whole chip. FEM based analysis reveals that the outer surface temperature of the catheter is expected to remain below the 42 °C tissue damage limit during therapy.
Collapse
|
28
|
Scott SJ, Adams MS, Salgaonkar V, Sommer FG, Diederich CJ. Theoretical investigation of transgastric and intraductal approaches for ultrasound-based thermal therapy of the pancreas. J Ther Ultrasound 2017; 5:10. [PMID: 28469915 PMCID: PMC5414307 DOI: 10.1186/s40349-017-0090-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2016] [Accepted: 02/07/2017] [Indexed: 02/07/2023] Open
Abstract
Background The goal of this study was to theoretically investigate the feasibility of intraductal and transgastric approaches to ultrasound-based thermal therapy of pancreatic tumors, and to evaluate possible treatment strategies. Methods This study considered ultrasound applicators with 1.2 mm outer diameter tubular transducers, which are inserted into the tissue to be treated by an endoscopic approach, either via insertion through the gastric wall (transgastric) or within the pancreatic duct lumen (intraductal). 8 patient-specific, 3D, transient, biothermal and acoustic finite element models were generated to model hyperthermia (n = 2) and ablation (n = 6), using sectored (210°–270°, n = 4) and 360° (n = 4) transducers for treatment of 3.3–17.0 cm3 tumors in the head (n = 5), body (n = 2), and tail (n = 1) of the pancreas. A parametric study was performed to determine appropriate treatment parameters as a function of tissue attenuation, blood perfusion rates, and distance to sensitive anatomy. Results Parametric studies indicated that pancreatic tumors up to 2.5 or 2.7 cm diameter can be ablated within 10 min with the transgastric and intraductal approaches, respectively. Patient-specific simulations demonstrated that 67.1–83.3% of the volumes of four sample 3.3–11.4 cm3 tumors could be ablated within 3–10 min using transgastric or intraductal approaches. 55.3–60.0% of the volume of a large 17.0 cm3 tumor could be ablated using multiple applicator positions within 20–30 min with either transgastric or intraductal approaches. 89.9–94.7% of the volume of two 4.4–11.4 cm3 tumors could be treated with intraductal hyperthermia. Sectored applicators are effective in directing acoustic output away from and preserving sensitive structures. When acoustic energy is directed towards sensitive structures, applicators should be placed at least 13.9–14.8 mm from major vessels like the aorta, 9.4–12.0 mm from other vessels, depending on the vessel size and flow rate, and 14 mm from the duodenum. Conclusions This study demonstrated the feasibility of generating shaped or conformal ablative or hyperthermic temperature distributions within pancreatic tumors using transgastric or intraductal ultrasound.
Collapse
Affiliation(s)
- Serena J Scott
- Department of Radiation Oncology, Thermal Therapy Research Group, University of California, San Francisco, 1600 Divisadero Street, Suite H1031, San Francisco, CA 94143-1708 USA
| | - Matthew S Adams
- Department of Radiation Oncology, Thermal Therapy Research Group, University of California, San Francisco, 1600 Divisadero Street, Suite H1031, San Francisco, CA 94143-1708 USA.,UC Berkeley - UC San Francisco Graduate Program in Bioengineering, California, USA
| | - Vasant Salgaonkar
- Department of Radiation Oncology, Thermal Therapy Research Group, University of California, San Francisco, 1600 Divisadero Street, Suite H1031, San Francisco, CA 94143-1708 USA
| | - F Graham Sommer
- Department of Radiology, Stanford University School of Medicine, Stanford, CA USA
| | - Chris J Diederich
- Department of Radiation Oncology, Thermal Therapy Research Group, University of California, San Francisco, 1600 Divisadero Street, Suite H1031, San Francisco, CA 94143-1708 USA.,UC Berkeley - UC San Francisco Graduate Program in Bioengineering, California, USA
| |
Collapse
|
29
|
Adams MS, Salgaonkar VA, Plata-Camargo J, Jones PD, Pascal-Tenorio A, Chen HY, Bouley DM, Sommer G, Pauly KB, Diederich CJ. Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model. Med Phys 2017; 43:4184. [PMID: 27370138 DOI: 10.1118/1.4953632] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
PURPOSE Endoluminal ultrasound may serve as a minimally invasive option for delivering thermal ablation to pancreatic tumors adjacent to the stomach or duodenum. The objective of this study was to explore the basic feasibility of this treatment strategy through the design, characterization, and evaluation of proof-of-concept endoluminal ultrasound applicators capable of placement in the gastrointestinal (GI) lumen for volumetric pancreas ablation under MR guidance. METHODS Two variants of the endoluminal applicator, each containing a distinct array of two independently powered transducers (10 × 10 mm 3.2 MHz planar; or 8 × 10 × 20 mm radius of curvature 3.3 MHz curvilinear geometries) at the distal end of a meter long flexible catheter assembly, were designed and fabricated. Transducers and circulatory water flow for acoustic coupling and luminal cooling were contained by a low-profile polyester balloon covering the transducer assembly fixture. Each applicator incorporated miniature spiral MR coils and mechanical features (guiding tips and hinges) to facilitate tracking and insertion through the GI tract under MRI guidance. Acoustic characterization of each device was performed using radiation force balance and hydrophone measurements. Device delivery into the upper GI tract, adjacent to the pancreas, and heating characteristics for treatment of pancreatic tissue were evaluated in MR-guided ex vivo and in vivo porcine experiments. MR guidance was utilized for anatomical target identification, tracking/positioning of the applicator, and MR temperature imaging (MRTI) for PRF-based multislice thermometry, implemented in the real-time RTHawk software environment. RESULTS Force balance and hydrophone measurements indicated efficiencies of 48.8% and 47.8% and -3 dB intensity beam-widths of 3.2 and 1.2 mm for the planar and curvilinear transducers, respectively. Ex vivo studies on whole-porcine carcasses revealed capabilities of producing ablative temperature rise (ΔT > 15 °C) contours in pancreatic tissue 4-40 mm long and 4-28 mm wide for the planar transducer applicator (1-13 min sonication duration, ∼4 W/cm(2) applied acoustic intensity). Curvilinear transducers produced more selective heating, with a narrower ΔT > 15 °C contour length and width of up to 1-24 mm and 2-7 mm, respectively (1-7 min sonication duration, ∼4 W/cm(2) applied acoustic intensity). Active tracking of the miniature spiral coils was achieved using a Hadamard encoding tracking sequence, enabling real-time determination of each coil's coordinates and automated prescription of imaging planes for thermometry. In vivo MRTI-guided heating trials in three pigs demonstrated capability of ∼20 °C temperature elevation in pancreatic tissue at 2 cm depths from the applicator, with 5-7 W/cm(2) applied intensity and 6-16 min sonication duration. Dimensions of thermal lesions in the pancreas ranged from 12 to 28 mm, 3 to 10 mm, and 5 to 10 mm in length, width, and depth, respectively, as verified through histological analysis of tissue sections. Multiple-baseline reconstruction and respiratory-gated acquisition were demonstrated to be effective strategies in suppressing motion artifacts for clear evolution of temperature profiles during MRTI in the in vivo studies. CONCLUSIONS This study demonstrates the technical feasibility of generating volumetric ablation in pancreatic tissue using endoluminal ultrasound applicators positioned in the stomach lumen. MR guidance facilitates target identification, device tracking/positioning, and treatment monitoring through real-time multislice PRF-based thermometry.
Collapse
Affiliation(s)
- Matthew S Adams
- Thermal Therapy Research Group, University of California, San Francisco, 2340 Sutter Street, S341, San Francisco, California 94115 and The UC Berkeley - UCSF Graduate Program in Bioengineering, University of California, Berkeley, and University of California, San Francisco, California 94115
| | - Vasant A Salgaonkar
- Thermal Therapy Research Group, University of California, San Francisco, 2340 Sutter Street, S341, San Francisco, California 94115
| | - Juan Plata-Camargo
- Department of Radiology, Stanford University, Stanford, California 94305
| | - Peter D Jones
- Thermal Therapy Research Group, University of California, San Francisco, 2340 Sutter Street, S341, San Francisco, California 94115
| | - Aurea Pascal-Tenorio
- Department of Comparative Medicine, Stanford University, Stanford, California 94305
| | - Hsin-Yu Chen
- The UC Berkeley - UCSF Graduate Program in Bioengineering, University of California, Berkeley, and University of California, San Francisco, California 94115
| | - Donna M Bouley
- Department of Comparative Medicine, Stanford University, Stanford, California 94305
| | - Graham Sommer
- Department of Radiology, Stanford University, Stanford, California 94305
| | - Kim Butts Pauly
- Department of Radiology, Stanford University, Stanford, California 94305
| | - Chris J Diederich
- Thermal Therapy Research Group, University of California, San Francisco, 2340 Sutter Street, S341, San Francisco, California 94115 and The UC Berkeley - UCSF Graduate Program in Bioengineering, University of California, Berkeley, and University of California, San Francisco, California 94115
| |
Collapse
|
30
|
Endoscopic Ultrasound and Related Technologies for the Diagnosis and Treatment of Pancreatic Disease - Research Gaps and Opportunities: Summary of a National Institute of Diabetes and Digestive and Kidney Diseases Workshop. Pancreas 2017; 46:1242-1250. [PMID: 28926412 PMCID: PMC5645254 DOI: 10.1097/mpa.0000000000000936] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
A workshop was sponsored by the National Institute of Diabetes and Digestive and Kidney Diseases to address the research gaps and opportunities in pancreatic endoscopic ultrasound (EUS). The event occurred on July 26, 2017 in 4 sessions: (1) benign pancreatic diseases, (2) high-risk pancreatic diseases, (3) diagnostic and therapeutics, and (4) new technologies. The current state of knowledge was reviewed, with identification of numerous gaps in knowledge and research needs. Common themes included the need for large multicenter consortia of various pancreatic diseases to facilitate meaningful research of these entities; to standardize EUS features of different pancreatic disorders, the technique of sampling pancreatic lesions, and the performance of various therapeutic EUS procedures; and to identify high-risk disease early at the cellular level before macroscopic disease develops. The need for specialized tools and accessories to enable the safe and effective performance of therapeutic EUS procedures also was discussed.
Collapse
|
31
|
Diana M, Schiraldi L, Liu YY, Memeo R, Mutter D, Pessaux P, Marescaux J. High intensity focused ultrasound (HIFU) applied to hepato-bilio-pancreatic and the digestive system-current state of the art and future perspectives. Hepatobiliary Surg Nutr 2016; 5:329-44. [PMID: 27500145 DOI: 10.21037/hbsn.2015.11.03] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
BACKGROUND High intensity focused ultrasound (HIFU) is emerging as a valid minimally-invasive image-guided treatment of malignancies. We aimed to review to current state of the art of HIFU therapy applied to the digestive system and discuss some promising avenues of the technology. METHODS Pertinent studies were identified through PubMed and Embase search engines using the following keywords, combined in different ways: HIFU, esophagus, stomach, liver, pancreas, gallbladder, colon, rectum, and cancer. Experimental proof of the concept of endoluminal HIFU mucosa/submucosa ablation using a custom-made transducer has been obtained in vivo in the porcine model. RESULTS Forty-four studies reported on the clinical use of HIFU to treat liver lesions, while 19 series were found on HIFU treatment of pancreatic cancers and four studies included patients suffering from both liver and pancreatic cancers, reporting on a total of 1,682 and 823 cases for liver and pancreas, respectively. Only very limited comparative prospective studies have been reported. CONCLUSIONS Digestive system clinical applications of HIFU are limited to pancreatic and liver cancer. It is safe and well tolerated. The exact place in the hepatocellular carcinoma (HCC) management algorithm remains to be defined. HIFU seems to add clear survival advantages over trans arterial chemo embolization (TACE) alone and similar results when compared to radio frequency (RF). For pancreatic cancer, HIFU achieves consistent cancer-related pain relief. Further research is warranted to improve targeting accuracy and efficacy monitoring. Furthermore, additional work is required to transfer this technology on appealing treatments such as endoscopic HIFU-based therapies.
Collapse
Affiliation(s)
- Michele Diana
- IRCAD, Research Institute Against Cancer of the Digestive System, Strasbourg, France;; IHU-Strasbourg, Institute for Image-Guided Surgery, Strasbourg, France
| | - Luigi Schiraldi
- IRCAD, Research Institute Against Cancer of the Digestive System, Strasbourg, France
| | - Yu-Yin Liu
- IRCAD, Research Institute Against Cancer of the Digestive System, Strasbourg, France;; Department of General Surgery, Chang Gung Memorial Hospital, Linkou, Chang Gung University, Taoyuan, Taiwan
| | - Riccardo Memeo
- IHU-Strasbourg, Institute for Image-Guided Surgery, Strasbourg, France;; Department of Digestive Surgery, University Hospital of Strasbourg, France
| | - Didier Mutter
- IRCAD, Research Institute Against Cancer of the Digestive System, Strasbourg, France;; Department of Digestive Surgery, University Hospital of Strasbourg, France
| | - Patrick Pessaux
- IHU-Strasbourg, Institute for Image-Guided Surgery, Strasbourg, France;; Department of Digestive Surgery, University Hospital of Strasbourg, France
| | - Jacques Marescaux
- IRCAD, Research Institute Against Cancer of the Digestive System, Strasbourg, France;; IHU-Strasbourg, Institute for Image-Guided Surgery, Strasbourg, France
| |
Collapse
|
32
|
Adams MS, Scott SJ, Salgaonkar VA, Sommer G, Diederich CJ. Thermal therapy of pancreatic tumours using endoluminal ultrasound: Parametric and patient-specific modelling. Int J Hyperthermia 2016; 32:97-111. [PMID: 27097663 DOI: 10.3109/02656736.2015.1119892] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
PURPOSE The aim of this study is to investigate endoluminal ultrasound applicator configurations for volumetric thermal ablation and hyperthermia of pancreatic tumours using 3D acoustic and biothermal finite element models. MATERIALS AND METHODS Parametric studies compared endoluminal heating performance for varying applicator transducer configurations (planar, curvilinear-focused, or radial-diverging), frequencies (1-5 MHz), and anatomical conditions. Patient-specific pancreatic head and body tumour models were used to evaluate feasibility of generating hyperthermia and thermal ablation using an applicator positioned in the duodenal or stomach lumen. Temperature and thermal dose were calculated to define ablation (> 240 EM(43 °C)) and moderate hyperthermia (40-45 °C) boundaries, and to assess sparing of sensitive tissues. Proportional-integral control was incorporated to regulate maximum temperature to 70-80 °C for ablation and 45 °C for hyperthermia in target regions. RESULTS Parametric studies indicated that 1-3 MHz planar transducers are the most suitable for volumetric ablation, producing 5-8 cm(3) lesion volumes for a stationary 5-min sonication. Curvilinear-focused geometries produce more localised ablation to 20-45 mm depth from the GI tract and enhance thermal sparing (T(max) < 42 °C) of the luminal wall. Patient anatomy simulations show feasibility in ablating 60.1-92.9% of head/body tumour volumes (4.3-37.2 cm(3)) with dose < 15 EM(43 °C) in the luminal wall for 18-48 min treatment durations, using 1-3 applicator placements in GI lumen. For hyperthermia, planar and radial-diverging transducers could maintain up to 8 cm(3) and 15 cm(3) of tissue, respectively, between 40-45 °C for a single applicator placement. CONCLUSIONS Modelling studies indicate the feasibility of endoluminal ultrasound for volumetric thermal ablation or hyperthermia treatment of pancreatic tumour tissue.
Collapse
Affiliation(s)
- Matthew S Adams
- a Thermal Therapy Research Group, University of California , San Francisco , California .,b University of California, Berkeley - University of California, San Francisco Graduate Program in Bioengineering , California , and
| | - Serena J Scott
- a Thermal Therapy Research Group, University of California , San Francisco , California
| | - Vasant A Salgaonkar
- a Thermal Therapy Research Group, University of California , San Francisco , California
| | - Graham Sommer
- c Stanford Medical Center , Stanford , California , USA
| | - Chris J Diederich
- a Thermal Therapy Research Group, University of California , San Francisco , California .,b University of California, Berkeley - University of California, San Francisco Graduate Program in Bioengineering , California , and
| |
Collapse
|
33
|
Kaplan J, Khalid A, Cosgrove N, Soomro A, Mazhar SM, Siddiqui AA. Endoscopic ultrasound-fine needle injection for oncological therapy. World J Gastrointest Oncol 2015; 7:466-72. [PMID: 26691224 PMCID: PMC4678393 DOI: 10.4251/wjgo.v7.i12.466] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2015] [Revised: 09/11/2015] [Accepted: 10/12/2015] [Indexed: 02/05/2023] Open
Abstract
The minimal invasiveness and precision of endoscopic ultrasound (EUS) has lead to both its widespread use as a diagnostic and staging modality for gastrointestinal and pancreaticobiliary malignancies, and to its expanding role as a therapeutic modality. EUS-guided celiac plexus neurolysis is now a well-accepted modality for palliation of pain in patients with pancreatic cancer. EUS-guided ablation, brachytherapy, fiducial marker placement, and antitumor agent injection have been described as methods of performing minimally invasive oncological therapy. EUS-fine needle injection may be performed as adjunctive, alternative, or palliative treatment. This review summarizes the studies to date that have described these methods. A literature search using the PubMed/MEDLINE databases was performed. While most published studies to date are limited with disappointing outcomes, the concept of a role of EUS in oncological therapy seems promising.
Collapse
|