1
|
Buerck JP, Foster KM, Larson PR, O'Rear EA. Shear stimulated red blood cell microparticles: Effect on clot structure, flow and fibrinolysis. Biorheology 2023; 59:43-59. [PMID: 36970891 DOI: 10.3233/bir-220012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
BACKGROUND Microparticles (MPs) have activity in thrombus promotion and generation. Erythrocyte microparticles (ErMPs) have been reported to accelerate fibrinolysis in the absence of permeation. We hypothesized that shear induced ErMPs would affect fibrin structure of clots and change flow with implications for fibrinolysis. OBJECTIVE To determine the effect of ErMPs on clot structure and fibrinolysis. METHODS Plasma with elevated ErMPs was isolated from whole blood or from washed red blood cells (RBCs) resuspended in platelet free plasma (PFP) after high shear. Dynamic light scattering (DLS) provided size distribution of ErMPs from sheared samples and unsheared PFP controls. Clots were formed by recalcification for flow/lysis experiments and examined by confocal microscopy and SEM. Flow rates through clots and time-to-lysis were recorded. A cellular automata model showed the effect of ErMPs on fibrin polymerization and clot structure. RESULTS Coverage of fibrin increased by 41% in clots formed from plasma of sheared RBCs in PFP over controls. Flow rate decreased by 46.7% under a pressure gradient of 10 mmHg/cm with reduction in time to lysis from 5.7 ± 0.7 min to 12.2 ± 1.1 min (p < 0.01). Particle size of ErMPs from sheared samples (200 nm) was comparable to endogenous microparticles. CONCLUSIONS ErMPs alter the fibrin network in a thrombus and affect hydraulic permeability resulting in decelerated delivery of fibrinolytic drugs.
Collapse
Affiliation(s)
- James P Buerck
- School of Chemical, Biological and Materials Engineering, University of Oklahoma, Norman, OK, USA
| | - Kylie M Foster
- School of Chemical, Biological and Materials Engineering, University of Oklahoma, Norman, OK, USA
| | - Preston R Larson
- Samuel Roberts Noble Electron Microscopy Laboratory, University of Oklahoma, Norman, OK, USA
| | - Edgar A O'Rear
- School of Chemical, Biological and Materials Engineering, University of Oklahoma, Norman, OK, USA
- Institute for Biomedical Engineering, Science and Technology, University of Oklahoma, Norman, OK, USA
| |
Collapse
|
2
|
Arias K, Sun W, Wang S, Sorensen EN, Feller E, Kaczorowski D, Griffith B, Wu ZJ. Acquired platelet defects are responsible for nonsurgical bleeding in left ventricular assist device recipients. Artif Organs 2022; 46:2244-2256. [PMID: 35596611 PMCID: PMC11382350 DOI: 10.1111/aor.14319] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 04/02/2022] [Accepted: 05/13/2022] [Indexed: 11/27/2022]
Abstract
BACKGROUND Left ventricular assist devices (LVADs) have been used as a standard treatment option for patients with advanced heart failure. However, these devices are prone to adverse events. Nonsurgical bleeding (NSB) is the most common complication in patients with continuous flow (CF) LVADs. The development of acquired von Willebrand syndrome (AVWS) in CF-LVAD recipients is thought to be a key factor. However, AVWS is seen across a majority of LVAD patients, not just those with NSB. The purpose of this study was to examine the link between acquired platelet defects and NSB in CF-LVAD patients. METHODS Blood samples were collected from 62 CF-LVAD patients at pre- and 4 post-implantation timepoints. Reduced adhesion receptor expression (GPIbα and GPVI) and activation of platelets (GPIIb/IIIa activation) were used as markers for acquired platelet defects. RESULTS Twenty-three patients experienced at least one NSB episode. Significantly higher levels of platelet activation and receptor reduction were seen in the postimplantation blood samples from bleeders compared with non-bleeders. All patients experienced the loss of high molecular weight monomers (HMWM) of von Willebrand Factor (vWF), but no difference was seen between the two groups. Multivariable logistic regression showed that biomarkers for reduced platelet receptor expression (GPIbα and GPVI) and activation (GPIIb/IIIa) have more predictive power for NSB, with the area under curve (AUC) values of 0.72, 0.68, and 0.62, respectively, than the loss of HMWM of vWF (AUC: 0.57). CONCLUSION The data from this study indicated that the severity of acquired platelet defects has a direct link to NSB in CF-LVAD recipients.
Collapse
Affiliation(s)
- Katherin Arias
- Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, Maryland, USA
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Wenji Sun
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Shigang Wang
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Erik N Sorensen
- Division of Perioperative Services, University of Maryland Medical Center, Baltimore, Maryland, USA
| | - Erika Feller
- Department of Medicine, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - David Kaczorowski
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Bartley Griffith
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Zhongjun J Wu
- Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, Maryland, USA
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| |
Collapse
|
3
|
Comparison of the Hemocompatibility of an Axial and a Centrifugal Left Ventricular Assist Device in an In Vitro Test Circuit. J Clin Med 2022; 11:jcm11123431. [PMID: 35743501 PMCID: PMC9225365 DOI: 10.3390/jcm11123431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 06/08/2022] [Accepted: 06/13/2022] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Hemocompatibility of left ventricular assist devices is essential for preventing adverse events. In this study, we compared the hemocompatibility of an axial-flow (Sputnik) to a centrifugal-flow (HeartMate 3) pump. METHODS Both pumps were integrated into identical in vitro test circuits, each filled with 75 mL heparinized human blood of the same donor. During each experiment (n = 7), the pumps were operated with equal flow for six hours. Blood sampling and analysis were performed on a regular schedule. The analytes were indicators of hemolysis, coagulation activation, platelet count and activation, as well as extracellular vesicles. RESULTS Sputnik induced higher hemolysis compared to the HeartMate 3 after 360 min. Furthermore, platelet activation was higher for Sputnik after 120 min onward. In the HeartMate 3 circuit, the platelet count was reduced within the first hour. Furthermore, Sputnik triggered a more pronounced increase in extracellular vesicles, a potential trigger for adverse events in left ventricular assist device application. Activation of coagulation showed a time-dependent increase, with no differences between both groups. CONCLUSIONS This experimental study confirms the hypothesis that axial-flow pumps may induce stronger hemolysis compared to centrifugal pumps, coming along with larger amounts of circulating extracellular vesicles and a stronger PLT activation.
Collapse
|
4
|
Zifkos K, Dubois C, Schäfer K. Extracellular Vesicles and Thrombosis: Update on the Clinical and Experimental Evidence. Int J Mol Sci 2021; 22:ijms22179317. [PMID: 34502228 PMCID: PMC8431093 DOI: 10.3390/ijms22179317] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 08/24/2021] [Accepted: 08/25/2021] [Indexed: 12/16/2022] Open
Abstract
Extracellular vesicles (EVs) compose a heterogenous group of membrane-derived particles, including exosomes, microvesicles and apoptotic bodies, which are released into the extracellular environment in response to proinflammatory or proapoptotic stimuli. From earlier studies suggesting that EV shedding constitutes a cellular clearance mechanism, it has become evident that EV formation, secretion and uptake represent important mechanisms of intercellular communication and exchange of a wide variety of molecules, with relevance in both physiological and pathological situations. The putative role of EVs in hemostasis and thrombosis is supported by clinical and experimental studies unraveling how these cell-derived structures affect clot formation (and resolution). From those studies, it has become clear that the prothrombotic effects of EVs are not restricted to the exposure of tissue factor (TF) and phosphatidylserines (PS), but also involve multiplication of procoagulant surfaces, cross-linking of different cellular players at the site of injury and transfer of activation signals to other cell types. Here, we summarize the existing and novel clinical and experimental evidence on the role and function of EVs during arterial and venous thrombus formation and how they may be used as biomarkers as well as therapeutic vectors.
Collapse
Affiliation(s)
- Konstantinos Zifkos
- Center for Thrombosis and Hemostasis, University Medical Center Mainz, D-55131 Mainz, Germany;
| | - Christophe Dubois
- Aix Marseille University, INSERM 1263, Institut National de la Recherche pour l’Agriculture, l’alimentation et l’Environnement (INRAE) 1260, Center for CardioVascular and Nutrition Research (C2VN), F-13380 Marseille, France;
| | - Katrin Schäfer
- Department of Cardiology, Cardiology I, University Medical Center Mainz, D-55131 Mainz, Germany
- Correspondence:
| |
Collapse
|
5
|
Thromboembolic Events in Patients With Left Ventricular Assist Devices Are Related to Microparticle-Induced Coagulation. ASAIO J 2021; 67:59-66. [PMID: 33346991 DOI: 10.1097/mat.0000000000001200] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
Thromboembolic events (TEs) are a feared complication in patients supported by a continuous-flow left ventricular assist device (LVAD). The aim of the study was to analyze the role of circulating microparticles (MPs) in activating the coagulation system in LVAD patients, which might contribute to the occurrence of TEs. First, we analyzed the effect of LVAD support on endothelial function, on the levels of endothelial MPs (EMPs) and platelet MPs (PMPs), and on the procoagulative activity of circulating MPs (measured as MP-induced thrombin formation) before LVAD implantation, post-implantation, and at a 3 month follow-up (n = 15). Second, these parameters were analyzed in 43 patients with ongoing LVAD support who were followed up for the occurrence of TEs in the following 12 months. In patients undergoing LVAD implantation, the levels of PMPs and MP-induced thrombin formation increased post-LVAD implantation. The flow-mediated vasodilation (FMD) decreased, while the levels of EMPs increased post-LVAD implantation. TEs occurred in eight patients with ongoing LVAD support despite adequate coagulation. The levels of PMPs and MP-induced thrombin formation were higher in LVAD patients with TEs than in LVAD patients without TEs and were independent predictors for the risk of TEs under LVAD support. As conclusion, implantation of LVAD enhanced MP-induced coagulation, which was independently associated with the occurrence of TEs. These parameters may serve in risk stratification for early transplantation and individualized modification of standard LVAD therapy.
Collapse
|
6
|
Roka-Moiia Y, Li M, Ivich A, Muslmani S, Kern KB, Slepian MJ. Impella 5.5 Versus Centrimag: A Head-to-Head Comparison of Device Hemocompatibility. ASAIO J 2021; 66:1142-1151. [PMID: 33136602 PMCID: PMC7594535 DOI: 10.1097/mat.0000000000001283] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Despite growing use of mechanical circulatory support, limitations remain related to hemocompatibility. Here, we performed a head-to-head comparison of the hemocompatibility of a centrifugal cardiac assist system-the Centrimag, with that of the latest generation of an intravascular microaxial system-the Impella 5.5. Specifically, hemolysis, platelet activation, microparticle (MP) generation, and von Willebrand factor (vWF) degradation were evaluated for both devices. Freshly obtained porcine blood was recirculated within device propelled mock loops for 4 hours, and alteration of the hemocompatibility parameters was monitored over time. We found that the Impella 5.5 and Centrimag exhibited low levels of hemolysis, as indicated by minor increase in plasma free hemoglobin. Both devices did not induce platelet degranulation, as no alteration of β-thromboglobulin and P-selectin in plasma occurred, rather minor downregulation of platelet surface P-selectin was detected. Furthermore, blood exposure to shear stress via both Centrimag and Impella 5.5 resulted in a minor decrease of platelet count with associated ejection of procoagulant MPs, and a decrease of vWF functional activity (but not plasma level of vWF-antigen). Greater MP generation was observed with the Centrimag relative to the Impella 5.5. Thus, the Impella 5.5 despite having a lower profile and higher impeller rotational speed demonstrated good and equivalent hemocompatibility, in comparison with the predicate Centrimag, with the advantage of lower generation of MPs.
Collapse
Affiliation(s)
- Yana Roka-Moiia
- From the Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, Arizona
| | - Mengtang Li
- Department of Mechanical Engineering, Vanderbilt University, Nashville, Tennessee
| | - Adriana Ivich
- Department of Mechanical Engineering, Vanderbilt University, Nashville, Tennessee
| | - Sami Muslmani
- From the Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, Arizona
| | - Karl B. Kern
- From the Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, Arizona
| | - Marvin J. Slepian
- From the Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, Arizona
- Department of Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, Arizona
| |
Collapse
|
7
|
Wang S, Griffith BP, Wu ZJ. Device-Induced Hemostatic Disorders in Mechanically Assisted Circulation. Clin Appl Thromb Hemost 2021; 27:1076029620982374. [PMID: 33571008 PMCID: PMC7883139 DOI: 10.1177/1076029620982374] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Mechanically assisted circulation (MAC) sustains the blood circulation in the body of a patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) or on ventricular assistance with a ventricular assist device (VAD) or on extracorporeal membrane oxygenation (ECMO) with a pump-oxygenator system. While MAC provides short-term (days to weeks) support and long-term (months to years) for the heart and/or lungs, the blood is inevitably exposed to non-physiological shear stress (NPSS) due to mechanical pumping action and in contact with artificial surfaces. NPSS is well known to cause blood damage and functional alterations of blood cells. In this review, we discussed shear-induced platelet adhesion, platelet aggregation, platelet receptor shedding, and platelet apoptosis, shear-induced acquired von Willebrand syndrome (AVWS), shear-induced hemolysis and microparticle formation during MAC. These alterations are associated with perioperative bleeding and thrombotic events, morbidity and mortality, and quality of life in MCS patients. Understanding the mechanism of shear-induce hemostatic disorders will help us develop low-shear-stress devices and select more effective treatments for better clinical outcomes.
Collapse
Affiliation(s)
- Shigang Wang
- Department of Surgery, 12264University of Maryland School of Medicine, Baltimore, MD, USA
| | - Bartley P Griffith
- Department of Surgery, 12264University of Maryland School of Medicine, Baltimore, MD, USA
| | - Zhongjun J Wu
- Department of Surgery, 12264University of Maryland School of Medicine, Baltimore, MD, USA.,Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, MD, USA
| |
Collapse
|
8
|
Roka-Moiia Y, Miller-Gutierrez S, Palomares DE, Italiano JE, Sheriff J, Bluestein D, Slepian MJ. Platelet Dysfunction During Mechanical Circulatory Support: Elevated Shear Stress Promotes Downregulation of α IIbβ 3 and GPIb via Microparticle Shedding Decreasing Platelet Aggregability. Arterioscler Thromb Vasc Biol 2021; 41:1319-1336. [PMID: 33567867 DOI: 10.1161/atvbaha.120.315583] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
[Figure: see text].
Collapse
Affiliation(s)
- Yana Roka-Moiia
- Department of Medicine (Y.R.-M., S.M.-G.), Sarver Heart Center, University of Arizona, Tucson
| | - Samuel Miller-Gutierrez
- Department of Medicine (Y.R.-M., S.M.-G.), Sarver Heart Center, University of Arizona, Tucson
| | - Daniel E Palomares
- Department of Biomedical Engineering (D.E.P., M.J.S.), Sarver Heart Center, University of Arizona, Tucson
| | - Joseph E Italiano
- Brigham and Woman's Hospital, Harvard Medical School, Boston, MA (J.E.I.)
| | - Jawaad Sheriff
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY (J.S., D.B., M.J.S.)
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY (J.S., D.B., M.J.S.)
| | - Marvin J Slepian
- Department of Biomedical Engineering (D.E.P., M.J.S.), Sarver Heart Center, University of Arizona, Tucson.,Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY (J.S., D.B., M.J.S.)
| |
Collapse
|
9
|
Production of erythrocyte microparticles in a sub-hemolytic environment. J Artif Organs 2021; 24:135-145. [PMID: 33420875 DOI: 10.1007/s10047-020-01231-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Accepted: 11/25/2020] [Indexed: 01/14/2023]
Abstract
Microparticles are produced by various cells due to a number of different stimuli in the circulatory system. Shear stress has been shown to injure red blood cells resulting in hemolysis or non-reversible sub-hemolytic damage. We hypothesized that, in the sub-hemolytic shear range, there exist sufficient mechanical stimuli for red blood cells to respond with production of microparticles. Red blood cells isolated from blood of healthy volunteers were exposed to high shear stress in a microfluidic channel to mimic mechanical trauma similar to that occurring in ventricular assist devices. Utilizing flow cytometry techniques, both an increase of shear rate and exposure time showed higher concentrations of red blood cell microparticles. Controlled shear rate exposure shows that red blood cell microparticle concentration may be indicative of sub-hemolytic damage to red blood cells. In addition, properties of these red blood cell microparticles produced by shear suggest that mechanical trauma may underlie some complications for cardiovascular patients.
Collapse
|
10
|
Asuka E, Pak S, Thiess AK, Torres A. Gastrointestinal Bleeding as a Complication in Continuous Flow Ventricular Assist Devices: A Systematic Review With Meta-Analysis. J Clin Med Res 2020; 12:543-559. [PMID: 32849943 PMCID: PMC7430922 DOI: 10.14740/jocmr4262] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Accepted: 06/26/2020] [Indexed: 12/24/2022] Open
Abstract
Background The use of ventricular assist devices (VADs) has become predominant in this era of medicine. It is commonly used as a bridge to transplant, recovery and as a destination therapy for patients with severe heart failure, who are not responsive to maximum optimal management or ineligible for transplant. However, several complications are known to occur with the use of these devices. In this research, we will compare gastrointestinal bleeding in patients who used centrifugal flow versus axial flow VADs. We hope that the result of this meta-analysis and the review presented provide adequate information to future researchers, physicians and other healthcare professionals who are interested in this topic. Methods Published articles evaluated for inclusion were obtained from MEDLINE (PubMed), Cochrane, EBSCO, clinicaltrials.gov, and international clinical trials registry. This research was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Procured articles were reviewed by two independent reviewers. Only randomized control trials and observational studies were used. Quality assessment was done with Cochrane Collaboration’s tool (RoB.2 with visualization through robviz) and Newcastle-Ottawa Scale (NOS). Data analysis was carried out with the use of R data analysis tool (version 4.0.0; release date: April 24th, 2020). Results At the end of this meta-analysis, the occurrence of gastrointestinal bleeding was not significantly different between both groups; with odds ratio (OR): 0.81; 95% confidence interval (CI): 0.65 - 1.00; P value = 0.05. Between-study variance (Tau-squared) was zero (0), standard error (SE) = 0.06. The degree of heterogeneity measured with I-squared statistic was 0% (minimal). Egger’s regression test was not statistically significant, P = 0.93. Symmetry of distribution was observed on the funnel plot. Trim and fill analysis showed no missing studies on the left; SE = 1.68. Conclusions The result obtained from this research indicates that the occurrence of gastrointestinal bleeding is not significantly different in both groups of patients, irrespective of the type of continuous flow VAD used. Although, the study sample used in this meta-analysis was limited.
Collapse
Affiliation(s)
- Edinen Asuka
- All Saints University School Of Medicine, Hillsborough St, Roseau, Dominica
| | - Stella Pak
- Department of Medicine, Orange Regional Medical Center, 707 East Main Street, Middletown, NY 10940, USA
| | - Armond-Kristopher Thiess
- Department of Medicine, Universidad Autonoma de Guadalajara, Av. Patria 1201, Lomas del Valle 45129, Zapopan, Mexico
| | - Anthony Torres
- Department of Medicine, Universidad Autonoma de Guadalajara, Av. Patria 1201, Lomas del Valle 45129, Zapopan, Mexico
| |
Collapse
|
11
|
In Vitro Benchmarking Study of Ventricular Assist Devices in Current Clinical Use. J Card Fail 2020; 26:70-79. [DOI: 10.1016/j.cardfail.2019.09.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Revised: 09/24/2019] [Accepted: 09/28/2019] [Indexed: 01/26/2023]
|
12
|
Gorbet M, Sperling C, Maitz MF, Siedlecki CA, Werner C, Sefton MV. The blood compatibility challenge. Part 3: Material associated activation of blood cascades and cells. Acta Biomater 2019; 94:25-32. [PMID: 31226478 DOI: 10.1016/j.actbio.2019.06.020] [Citation(s) in RCA: 67] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 05/03/2019] [Accepted: 06/13/2019] [Indexed: 01/09/2023]
Abstract
Following protein adsorption/activation which is the first step after the contact of material surfaces and whole blood (part 2), fibrinogen is converted to fibrin and platelets become activated and assembled in the form of a thrombus. This thrombus formation is the key feature that needs to be minimized in the creation of materials with low thrombogenicity. Further aspects of blood compatibility that are important on their own are complement and leukocyte activation which are also important drivers of thrombus formation. Hence this review summarizes the state of knowledge on all of these cascades and cells and their interactions. For each cascade or cell type, the chapter distinguishes statements which are in widespread agreement from statements where there is less of a consensus. STATEMENT OF SIGNIFICANCE: This paper is part 3 of a series of 4 reviews discussing the problem of biomaterial associated thrombogenicity. The objective was to highlight features of broad agreement and provide commentary on those aspects of the problem that were subject to dispute. We hope that future investigators will update these reviews as new scholarship resolves the uncertainties of today.
Collapse
Affiliation(s)
- Maud Gorbet
- Department of Systems Design Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Claudia Sperling
- Institute Biofunctional Polymer Materials, Max Bergmann Center of Biomaterials, Leibniz-Institut für Polymerforschung Dresden e.V., Dresden, Germany
| | - Manfred F Maitz
- Institute Biofunctional Polymer Materials, Max Bergmann Center of Biomaterials, Leibniz-Institut für Polymerforschung Dresden e.V., Dresden, Germany
| | - Christopher A Siedlecki
- Departments of Surgery and Bioengineering, The Pennsylvania State University, College of Medicine, Hershey, PA 17033, United States
| | - Carsten Werner
- Institute Biofunctional Polymer Materials, Max Bergmann Center of Biomaterials, Leibniz-Institut für Polymerforschung Dresden e.V., Dresden, Germany
| | - Michael V Sefton
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada.
| |
Collapse
|
13
|
Abstract
Microparticles are a distinctive group of small vesicles, without nucleus, which are involved as significant modulators in several physiological and pathophysiological mechanisms. Plasma microparticles from various cellular lines have been subject of research. Data suggest that they are key players in development and manifestation of cardiovascular diseases and their presence, in high levels, is associated with chronic inflammation, endothelial damage and thrombosis. The strong correlation of microparticle levels with several outcomes in cardiovascular diseases has led to their utilization as biomarkers. Despite the limited clinical application at present, their significance emerges, mainly because their detection and enumeration methods are improving. This review article summarizes the evidence derived from research, related with the genesis and the function of microparticles in the presence of various cardiovascular risk factors and conditions. The current data provide a substrate for several theories of how microparticles influence various cellular mechanisms by transferring biological information.
Collapse
Affiliation(s)
- Christos Voukalis
- a Institute of Cardiovascular Sciences , University of Birmingham , Birmingham , UK
| | - Eduard Shantsila
- a Institute of Cardiovascular Sciences , University of Birmingham , Birmingham , UK
| | - Gregory Y H Lip
- b Liverpool Centre for Cardiovascular Science , University of Liverpool and Liverpool Heart & Chest Hospital , Liverpool , UK.,c Department of Clinical Medicine, Aalborg Thrombosis Research Unit , Aalborg University , Aalborg , Denmark
| |
Collapse
|
14
|
Radley G, Laura Pieper I, Thomas BR, Hawkins K, Thornton CA. Artificial shear stress effects on leukocytes at a biomaterial interface. Artif Organs 2019; 43:E139-E151. [PMID: 30537257 DOI: 10.1111/aor.13409] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Revised: 10/17/2018] [Accepted: 11/29/2018] [Indexed: 12/11/2022]
Abstract
Medical devices, such as ventricular assist devices (VADs), introduce both foreign materials and artificial shear stress to the circulatory system. The effects these have on leukocytes and the immune response are not well understood. Understanding how these two elements combine to affect leukocytes may reveal why some patients are susceptible to recurrent device-related infections and provide insight into the development of pump thrombosis. Biomaterials-DLC: diamond-like carbon-coated stainless steel; Sap: single-crystal sapphire; and Ti: titanium alloy (Ti6 Al4 V) were attached to the parallel plates of a rheometer. Whole human blood was left between the two discs for 5 minutes at +37°C with or without the application of shear stress (0 s-1 or 1000 s-1 ). Blood was removed and used for complete blood cell counts, flow cytometry (leukocyte activation, cell death, microparticle generation, phagocytic ability, and reactive oxygen species [ROS] production), and the production of pro-inflammatory cytokines. L-selectin expression on monocytes was decreased when blood was exposed to the biomaterials both with and without shear. Applying shear stress to blood on a Sap and Ti surface led to activation of neutrophils shown as decreased L-selectin expression. Sap and Ti blunted the LPS-stimulated macrophage migration inhibitory factor (MIF) production, most notably when sheared on Ti. The biomaterials used here have been shown to activate leukocytes in a static environment. The introduction of shear appears to exacerbate this activation. Interestingly, a widely accepted biocompatible material (Ti) utilized in many different types of devices has the capacity for immune cell activation and inhibition of MIF secretion when combined with shear stress. These findings contribute to our understanding of the contribution of biomaterials and shear stress to recurrent infections and vulnerability to sepsis in some VAD patients as well as pump thrombosis.
Collapse
Affiliation(s)
- Gemma Radley
- Swansea University Medical School, Swansea, UK.,Calon Cardio-Technology Ltd, Institute of Life Science, Swansea, UK
| | | | | | | | | |
Collapse
|
15
|
Radley G, Ali S, Pieper IL, Thornton CA. Mechanical shear stress and leukocyte phenotype and function: Implications for ventricular assist device development and use. Int J Artif Organs 2018; 42:133-142. [PMID: 30585115 DOI: 10.1177/0391398818817326] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Heart failure remains a disease of ever increasing prevalence in the modern world. Patients with end-stage heart failure are being referred increasingly for mechanical circulatory support. Mechanical circulatory support can assist patients who are ineligible for transplant and stabilise eligible patients prior to transplantation. It is also used during cardiopulmonary bypass surgery to maintain circulation while operating on the heart. While mechanical circulatory support can stabilise heart failure and improve quality of life, complications such as infection and thrombosis remain a common risk. Leukocytes can contribute to both of these complications. Contact with foreign surfaces and the introduction of artificial mechanical shear stress can lead to the activation of leukocytes, reduced functionality and the release of pro-inflammatory and pro-thrombogenic microparticles. Assessing the impact of mechanical trauma to leukocytes is largely overlooked in comparison to red blood cells and platelets. This review provides an overview of the available literature on the effects of mechanical circulatory support systems on leukocyte phenotype and function. One purpose of this review is to emphasise the importance of studying mechanical trauma to leukocytes to better understand the occurrence of adverse events during mechanical circulatory support.
Collapse
Affiliation(s)
- Gemma Radley
- Swansea University Medical School, Swansea, UK
- Calon Cardio-Technology Ltd, Institute of Life Science, Swansea, UK
| | - Sabrina Ali
- Calon Cardio-Technology Ltd, Institute of Life Science, Swansea, UK
| | - Ina Laura Pieper
- Swansea University Medical School, Swansea, UK
- Scandinavian Real Heart AB, Västerås, Sweden
| | | |
Collapse
|
16
|
McVey MJ, Kuebler WM. Extracellular vesicles: biomarkers and regulators of vascular function during extracorporeal circulation. Oncotarget 2018; 9:37229-37251. [PMID: 30647856 PMCID: PMC6324688 DOI: 10.18632/oncotarget.26433] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2018] [Accepted: 11/26/2018] [Indexed: 12/12/2022] Open
Abstract
Extracellular vesicles (EVs) are generated at increased rates from parenchymal and circulating blood cells during exposure of the circulation to abnormal flow conditions and foreign materials associated with extracorporeal circuits (ExCors). This review describes types of EVs produced in different ExCors and extracorporeal life support (ECLS) systems including cardiopulmonary bypass circuits, extracorporeal membrane oxygenation (ECMO), extracorporeal carbon dioxide removal (ECCO2R), apheresis, dialysis and ventricular assist devices. Roles of EVs not only as biomarkers of adverse events during ExCor/ECLS use, but also as mediators of vascular dysfunction are explored. Manipulation of the number or subtypes of circulating EVs may prove a means of improving vascular function for individuals requiring ExCor/ECLS support. Strategies for therapeutic manipulation of EVs during ExCor/ECLS use are discussed such as accelerating their clearance, preventing their genesis or pharmacologic options to reduce or select which and how many EVs circulate. Strategies to reduce or select for specific types of EVs may prove beneficial in preventing or treating other EV-related diseases such as cancer.
Collapse
Affiliation(s)
- Mark J McVey
- Keenan Research Centre for Biomedical Science, St Michael's Hospital, Toronto, ON, Canada.,Department of Physiology, University of Toronto, Toronto, ON, Canada.,Department of Anesthesia, University of Toronto, Toronto, ON, Canada.,Department of Anesthesia and Pain Medicine, SickKids, Toronto, ON, Canada
| | - Wolfgang M Kuebler
- Keenan Research Centre for Biomedical Science, St Michael's Hospital, Toronto, ON, Canada.,Department of Physiology, University of Toronto, Toronto, ON, Canada.,Department of Surgery, University of Toronto, Toronto, ON, Canada.,Institute of Physiology, Charité-Universitätsmedizin Berlin, Berlin, Germany.,German Heart Institute, Berlin, Germany
| |
Collapse
|
17
|
Radley G, Pieper IL, Ali S, Bhatti F, Thornton CA. The Inflammatory Response to Ventricular Assist Devices. Front Immunol 2018; 9:2651. [PMID: 30498496 PMCID: PMC6249332 DOI: 10.3389/fimmu.2018.02651] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Accepted: 10/26/2018] [Indexed: 12/27/2022] Open
Abstract
The therapeutic use of ventricular assist devices (VADs) for end-stage heart failure (HF) patients who are ineligible for transplant has increased steadily in the last decade. In parallel, improvements in VAD design have reduced device size, cost, and device-related complications. These complications include infection and thrombosis which share underpinning contribution from the inflammatory response and remain common risks from VAD implantation. An added and underappreciated difficulty in designing a VAD that supports heart function and aids the repair of damaged myocardium is that different types of HF are accompanied by different inflammatory profiles that can affect the response to the implanted device. Circulating inflammatory markers and changes in leukocyte phenotypes receive much attention as biomarkers for mortality and disease progression. However, they are seldom used to monitor progress during and outcomes from VAD therapy or during the design phase for new devices. Even the partial reversal of heart damage associated with heart failure is a desirable outcome from VAD use. Therefore, improved understanding of the interplay between VADs and the recipient's inflammatory response would potentially increase their uptake, improve patient lives, and fuel research related to other blood-contacting medical devices. Here we provide a review of what is currently known about inflammation in heart failure and how this inflammatory profile is altered in heart failure patients receiving VAD therapy.
Collapse
Affiliation(s)
- Gemma Radley
- Swansea University Medical School, Swansea, United Kingdom.,Calon Cardio-Technology Ltd, Institute of Life Science, Swansea, United Kingdom
| | - Ina Laura Pieper
- Swansea University Medical School, Swansea, United Kingdom.,Scandinavian Real Heart AB, Västerås, Sweden
| | - Sabrina Ali
- Calon Cardio-Technology Ltd, Institute of Life Science, Swansea, United Kingdom
| | - Farah Bhatti
- Department of Cardiology, Morriston Hospital, Abertawe Bro Morgannwg University Health Board, Swansea, United Kingdom
| | | |
Collapse
|
18
|
Pieper IL, Radley G, Christen A, Ali S, Bodger O, Thornton CA. Ovine Leukocyte Microparticles Generated by the CentriMag Ventricular Assist Device In Vitro. Artif Organs 2018; 42:E78-E89. [PMID: 29512167 DOI: 10.1111/aor.13068] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2017] [Revised: 10/06/2017] [Accepted: 10/12/2017] [Indexed: 12/13/2022]
Abstract
Ventricular assist devices (VADs) are a life-saving form of mechanical circulatory support in heart failure patients. However, VADs have not yet reached their full potential due to the associated side effects (thrombosis, bleeding, infection) related to the activation and damage of blood cells and proteins caused by mechanical stress and foreign materials. Studies of the effects of VADs on leukocytes are limited, yet leukocyte activation and damage including microparticle generation can influence both thrombosis and infection rates. Therefore, the aim was to develop a multicolor flow cytometry assessment of leukocyte microparticles (LMPs) using ovine blood and the CentriMag VAD as a model for shear stress. Ovine blood was pumped for 6 h in the CentriMag and regular samples analyzed for hemolysis, complete blood counts and LMP by flow cytometry during three different pump operating conditions (low flow, standard, high speed). The high speed condition caused significant increases in plasma-free hemoglobin; decreases in total leukocytes, granulocytes, monocytes, and platelets; increases in CD45+ LMPs as well as two novel LMP populations: CD11bbright /HLA-DR- and CD11bdull /HLA-DR+ , both of which were CD14- /CD21- . CD11bbright /HLA-DR- LMPs appeared to respond to an increase in shear magnitude whereas the CD11bdull /HLA-DR+ LMPs significantly increased in all pumping conditions. We propose that these two populations are released from granulocytes and T cells, respectively, but further research is needed to better characterize these two populations.
Collapse
Affiliation(s)
- Ina Laura Pieper
- Institute of Life Science, Swansea University Medical School, Swansea, UK.,Calon Cardio-Technology Ltd, Institute of Life Science, Swansea, UK
| | - Gemma Radley
- Institute of Life Science, Swansea University Medical School, Swansea, UK.,Calon Cardio-Technology Ltd, Institute of Life Science, Swansea, UK
| | - Abigail Christen
- Calon Cardio-Technology Ltd, Institute of Life Science, Swansea, UK
| | - Sabrina Ali
- Calon Cardio-Technology Ltd, Institute of Life Science, Swansea, UK
| | - Owen Bodger
- Institute of Life Science, Swansea University Medical School, Swansea, UK
| | | |
Collapse
|
19
|
|
20
|
Miyamoto T, Karimov JH, Fukamachi K. Effects of continuous and pulsatile flows generated by ventricular assist devices on renal function and pathology. Expert Rev Med Devices 2018; 15:171-182. [DOI: 10.1080/17434440.2018.1437346] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Affiliation(s)
- Takuma Miyamoto
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, U.S.A
| | - Jamshid H. Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, U.S.A
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, U.S.A
| |
Collapse
|
21
|
Patricia Massicotte M, Bauman ME. Developmental hemostasis and ventricular assist devices: A troubled relationship. PROGRESS IN PEDIATRIC CARDIOLOGY 2017. [DOI: 10.1016/j.ppedcard.2017.08.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
22
|
Padera RF. A perfect storm: Understanding hemostasis, coagulation and inflammation with artificial material. PROGRESS IN PEDIATRIC CARDIOLOGY 2017. [DOI: 10.1016/j.ppedcard.2017.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
23
|
Bleeding and thrombosis associated with ventricular assist device therapy. J Heart Lung Transplant 2017; 36:1164-1173. [DOI: 10.1016/j.healun.2017.05.008] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Revised: 05/03/2017] [Accepted: 05/09/2017] [Indexed: 01/03/2023] Open
|
24
|
Radley G, Pieper IL, Thornton CA. The effect of ventricular assist device-associated biomaterials on human blood leukocytes. J Biomed Mater Res B Appl Biomater 2017; 106:1730-1738. [PMID: 28888071 DOI: 10.1002/jbm.b.33981] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Revised: 08/01/2017] [Accepted: 08/16/2017] [Indexed: 12/29/2022]
Abstract
Ventricular assist devices (VADs) are an effective bridging or destination therapy for patients with advanced stage heart failure. These devices remain susceptible to adverse events including infection, bleeding, and thrombus; events linked to the foreign body response. Therefore, the biocompatibility of all biomaterials used is crucial to the success of medical devices. Biomaterials common in VADs-DLC: diamond-like carbon coated stainless steel; Sap: single-crystal sapphire; SiN: silicon nitride; Ti: titanium alloy; and ZTA: zirconia-toughened alumina-were tested for their biocompatibility through incubation with whole human blood for 2 h with mild agitation. Blood was then removed and used for: complete cell counts; leukocyte activation and death, and the production of key inflammatory cytokines. All were compared to time 0 and an un-exposed 2 h sample. Monocyte numbers were lower after exposure to DLC, SiN, and ZTA and monocytes showed evidence of activation with DLC, Sap, and SiN. Neutrophils and lymphocytes were unaffected. This approach allows comprehensive analysis of the potential blood damaging effects of biomaterials. Monocyte activation by DLC, Sap, ZTA, and SiN warrants further investigation linking effects on this cell type to unfavorable inflammatory/thrombogenic responses to VADs and other blood handling devices. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1730-1738, 2018.
Collapse
Affiliation(s)
- Gemma Radley
- Institute of Life Science, Swansea University Medical School, Swansea, Wales, UK.,Calon Cardio - Technology Ltd., Institute of Life Science, Swansea, Wales, UK
| | - Ina Laura Pieper
- Institute of Life Science, Swansea University Medical School, Swansea, Wales, UK.,Calon Cardio - Technology Ltd., Institute of Life Science, Swansea, Wales, UK
| | - Catherine A Thornton
- Institute of Life Science, Swansea University Medical School, Swansea, Wales, UK
| |
Collapse
|
25
|
Chan CHH, Pieper IL, Robinson CR, Friedmann Y, Kanamarlapudi V, Thornton CA. Shear Stress-Induced Total Blood Trauma in Multiple Species. Artif Organs 2017; 41:934-947. [PMID: 28744884 DOI: 10.1111/aor.12932] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2016] [Revised: 12/26/2016] [Accepted: 01/24/2017] [Indexed: 12/16/2022]
Abstract
The common complications in heart failure patients with implanted ventricular assist devices (VADs) include hemolysis, thrombosis, and bleeding. These are linked to shear stress-induced trauma to erythrocytes, platelets, and von Willebrand factor (vWF). Novel device designs are being developed to reduce the blood trauma, which will need to undergo in vitro and in vivo preclinical testing in large animal models such as cattle, sheep, and pig. To fully understand the impact of device design and enable translation of preclinical results, it is important to identify any potential species-specific differences in the VAD-associated common complications. Therefore, the purpose of this study was to evaluate the effects of shear stress on cells and proteins in bovine, ovine, and porcine blood compared to human. Blood from different species was subjected to various shear rates (0-8000/s) using a rheometer. It was then analyzed for complete blood counts, hemolysis by the Harboe assay, platelet activation by flow cytometry, vWF structure by immunoblotting, and function by collagen binding activity ELISA (vWF : CBA). Overall, increasing shear rate caused increased total blood trauma in all tested species. This analysis revealed species-specific differences in shear-induced hemolysis, platelet activation, and vWF structure and function. Compared to human blood, porcine blood was the most resilient and showed less hemolysis, similar blood counts, but less platelet activation and less vWF damage in response to shear. Compared to human blood, sheared bovine blood showed less hemolysis, similar blood cell counts, greater platelet activation, and similar degradation of vWF structure, but less impact on its activity in response to shear. The shear-induced effect on ovine blood depended on whether the blood was collected via gravity at the abattoir or by venepuncture from live sheep. Overall, ovine abattoir blood was the least resilient in response to shear and bovine blood was the most similar to human blood. These results lay the foundations for developing blood trauma evaluation standards to enable the extrapolation of in vitro and in vivo animal data to predict safety and biocompatibility of blood-handling medical devices in humans. We advise using ovine venepuncture blood instead of ovine abattoir blood due to the greater overall damage in the latter. We propose using bovine blood for total blood damage in vitro device evaluation but multiple species could be used to create a full understanding of the complication risk profile of new devices. Further, this study highlights that choice of antibody clone for evaluating platelet activation in bovine blood can influence the interpretation of results from different studies.
Collapse
Affiliation(s)
- Chris H H Chan
- Institute of Life Science, Swansea University Medical School, Swansea, Wales, UK.,Institute of Life Science, Calon Cardio-Technology Ltd., Swansea, Wales, UK
| | - Ina Laura Pieper
- Institute of Life Science, Swansea University Medical School, Swansea, Wales, UK.,Institute of Life Science, Calon Cardio-Technology Ltd., Swansea, Wales, UK
| | - Christian R Robinson
- Institute of Life Science, Swansea University Medical School, Swansea, Wales, UK.,Institute of Life Science, Calon Cardio-Technology Ltd., Swansea, Wales, UK
| | - Yasmin Friedmann
- Institute of Life Science, Swansea University Medical School, Swansea, Wales, UK
| | | | - Catherine A Thornton
- Institute of Life Science, Swansea University Medical School, Swansea, Wales, UK
| |
Collapse
|
26
|
Vozel D, Uršič B, Krek JL, Štukelj R, Kralj-Iglič V. Applicability of extracellular vesicles in clinical studies. Eur J Clin Invest 2017; 47:305-313. [PMID: 28156006 DOI: 10.1111/eci.12733] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Accepted: 01/29/2017] [Indexed: 12/18/2022]
Abstract
BACKGROUND Extracellular vesicles (EVs) are submicron cellular fragments that mediate intercellular communication. EVs have in the last decade attracted major interest as biomarkers or platforms for biomarkers of health and disease. To better understand the reasons why despite great expectations and considerable effort, EV-based methods have not yet been introduced into clinical practice, we present a systematic analysis of published results of clinical studies. MATERIALS AND METHODS Clinical studies on populations of body fluid samples, published from 2010 to including 2015, applying centrifugation of fluid human samples with centrifuge accelerations up to about 25 000 g and flow cytometry for detection of EVs were analysed with respect to statistical significance (p), statistical power (P), clinical significance (CS), defined as the difference between the means divided by the sum of standard deviations, and size of the populations (Nmin ), defined as the number of samples in the smaller group. RESULTS Final analysis included 65 publications with 716 comparisons reporting 308 (43%) statistically significant differences (P < 0·05), 242 (34%) had statistical power P > 0·8 and 88 (12%) had clinical importance CS > 1·96. None of comparison with CS > 1·96 included populations in which the smaller group consisted of 50 or more samples. CONCLUSIONS To fulfil claimed expectations for EV-based methods as promising diagnostic tools, more evidence on EV-based mechanisms of diseases should be gathered. Also, the methods of EV harvesting and assessment should be improved to yield better repeatability and thus allow clinical studies with larger number of samples.
Collapse
Affiliation(s)
- Domen Vozel
- Laboratory of Clinical Biophysics, Faculty of Health Sciences, University of Ljubljana, Ljubljana, Slovenia
| | - Bojana Uršič
- Laboratory of Clinical Biophysics, Faculty of Health Sciences, University of Ljubljana, Ljubljana, Slovenia
| | - Judita Lea Krek
- Laboratory of Clinical Biophysics, Faculty of Health Sciences, University of Ljubljana, Ljubljana, Slovenia
| | - Roman Štukelj
- Laboratory of Clinical Biophysics, Faculty of Health Sciences, University of Ljubljana, Ljubljana, Slovenia
| | - Veronika Kralj-Iglič
- Laboratory of Clinical Biophysics, Faculty of Health Sciences, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
27
|
Stroke and Intracranial Hemorrhage in HeartMate II and HeartWare Left Ventricular Assist Devices: A Systematic Review. Neurocrit Care 2017; 27:17-25. [DOI: 10.1007/s12028-017-0386-7] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
28
|
Almizraq RJ, Seghatchian J, Acker JP. Extracellular vesicles in transfusion-related immunomodulation and the role of blood component manufacturing. Transfus Apher Sci 2016; 55:281-291. [DOI: 10.1016/j.transci.2016.10.018] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
29
|
Jeske WP, Walenga JM, Menapace B, Schwartz J, Bakhos M. Blood cell microparticles as biomarkers of hemostatic abnormalities in patients with implanted cardiac assist devices. Biomark Med 2016; 10:1095-1104. [DOI: 10.2217/bmm-2016-0150] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
For heart failure patients unable to undergo cardiac transplantation, mechanical circulatory support with left ventricular assist devices can be utilized. These devices improve quality of life and prolong life expectancy, but they are associated with bleeding and thrombotic complications impacting patient survival. Little is known of the relevant mechanisms of these hemostatic issues, hindering identification of a clinically useful biomarker. However, there is suggestive evidence that blood cell-derived microparticles may fulfill this unmet clinical need. Recent publications have shown an association of up regulated microparticle production with implanted left ventricular assist devices and the potential to use this as a biomarker to predict thrombosis (and perhaps other adverse events) with an onset time earlier than currently used clinical indicators.
Collapse
Affiliation(s)
- Walter P Jeske
- Department of Thoracic & Cardiovascular Surgery, Loyola University Medical Center, Maywood, IL 60153, USA
| | - Jeanine M Walenga
- Department of Thoracic & Cardiovascular Surgery, Loyola University Medical Center, Maywood, IL 60153, USA
| | - Bryan Menapace
- Department of Thoracic & Cardiovascular Surgery, Loyola University Medical Center, Maywood, IL 60153, USA
| | - Jeffrey Schwartz
- Department of Thoracic & Cardiovascular Surgery, Loyola University Medical Center, Maywood, IL 60153, USA
| | - Mamdouh Bakhos
- Department of Thoracic & Cardiovascular Surgery, Loyola University Medical Center, Maywood, IL 60153, USA
| |
Collapse
|
30
|
Ivak P, Pitha J, Netuka I. Circulating microparticles as a predictor of vascular properties in patients on mechanical circulatory support; hype or hope? Physiol Res 2016; 65:727-735. [PMID: 27429109 DOI: 10.33549/physiolres.933246] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Microparticles are small circulating vesicles originating from circulatory system and vascular wall cells released during their activation or damage. They possess different roles in regulation of endothelial function, inflammation, thrombosis, angiogenesis, and in general, cellular stress. Microparticles are the subject of intensive research in pulmonary hypertension, atherosclerotic disease, and heart failure. Another recently emerging role is the evaluation of the status of vasculature in end-stage heart failure patients treated with implantable ventricular assist devices. In patients implanted as destination therapy, assessment of the long-term effect of currently used continuous-flow left ventricular assist devices (LVADs) on vasculature might be of critical importance. However, unique continuous flow pattern generated by LVADs makes it difficult to assess reliably the vascular function with most currently used methods, based mainly on ultrasound detection of changes of arterial dilatation during pulsatile flow. In this respect, the measurement of circulating microparticles as a marker of vascular status may help to elucidate both short- and long-term effects of LVADs on the vascular system. Because data regarding this topic are very limited, this review is focused on the advantages and caveats of the circulating microparticles as markers of vascular function in patients on continuous-flow LVADs.
Collapse
Affiliation(s)
- P Ivak
- Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
| | | | | |
Collapse
|
31
|
Ivak P, Pitha J, Wohlfahrt P, Kralova Lesna I, Stavek P, Melenovsky V, Dorazilova Z, Hegarova M, Stepankova J, Maly J, Sekerkova A, Turcani D, Netuka I. Biphasic response in number of stem cells and endothelial progenitor cells after left ventricular assist device implantation: A 6month follow-up. Int J Cardiol 2016; 218:98-103. [PMID: 27232919 DOI: 10.1016/j.ijcard.2016.05.063] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2016] [Revised: 05/10/2016] [Accepted: 05/12/2016] [Indexed: 01/18/2023]
Abstract
BACKGROUND Continuous blood flow could have deleterious effects on endothelium and vascular health. This could have serious consequences in patients with heart failure treated with continuous flow left ventricular assist devices (LVAD). Therefore, we studied effect of LVAD on three circulating vascular biomarkers: stem cells (SC), endothelial progenitor cells (EPC) and microparticles (MP). METHODS In 23 patients (5 women) with end-stage heart failure, SC, EPC and MP were measured before, and 3 and 6months after implantation of LVAD (HeartMate II). SC were defined using determination of surface antigen expression as mononuclear CD34+/CD45low+ cells and EPC as mononuclear CD34+/CD45low+/KDR+ cells. MP concentrations were determined by ELISA method. RESULTS Three months after LVAD implantation numbers of SC and EPC significantly decreased (p=0.01 and p=0.001, respectively). On the contrary, between 3rd and 6th month after implantation they significantly increased (p=0.006 and p=0.003, respectively).MP did not change significantly during the study despite exerting similar trend as SC and EPC. CONCLUSIONS Observed biphasic changes of SC and EPC might reflect two processes. First, shortly after LVAD implantation, improved tissue perfusion could lead to decrease in ischemic stimuli and ensuing decrease of SC and EPC. Second, continuous flow between 3rd and 6th month produced by LVAD could lead to increase of SC and EPC through activation of endothelium. This explanation could be supported also by similar trend in the changes of concentrations of MP.
Collapse
Affiliation(s)
- Peter Ivak
- Department of Cardiac Surgery, Institute of Clinical and Experimental Medicine, Prague, Czech Republic; Third Faculty of Medicine, Charles University, Prague, Czech Republic
| | - Jan Pitha
- Laboratory for Atherosclerosis Research, Institute of Clinical and Experimental Medicine, Prague, Czech Republic; Department of Internal Medicine, 2(nd) Faculty of Medicine, Charles University in Prague, Czech Republic.
| | - Peter Wohlfahrt
- Laboratory for Atherosclerosis Research, Institute of Clinical and Experimental Medicine, Prague, Czech Republic; International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic
| | - Ivana Kralova Lesna
- Laboratory for Atherosclerosis Research, Institute of Clinical and Experimental Medicine, Prague, Czech Republic
| | - Petr Stavek
- Laboratory for Atherosclerosis Research, Institute of Clinical and Experimental Medicine, Prague, Czech Republic
| | - Vojtech Melenovsky
- Department of Cardiology, Institute of Clinical and Experimental Medicine, Prague, Czech Republic
| | - Zora Dorazilova
- Department of Cardiology, Institute of Clinical and Experimental Medicine, Prague, Czech Republic
| | - Marketa Hegarova
- Department of Cardiology, Institute of Clinical and Experimental Medicine, Prague, Czech Republic
| | - Jitka Stepankova
- Department of Cardiology, Institute of Clinical and Experimental Medicine, Prague, Czech Republic
| | - Jiri Maly
- Department of Cardiac Surgery, Institute of Clinical and Experimental Medicine, Prague, Czech Republic
| | - Alena Sekerkova
- Department of Clinical and Transplant Immunology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Dominika Turcani
- Department of Cardiac Surgery, Institute of Clinical and Experimental Medicine, Prague, Czech Republic
| | - Ivan Netuka
- Department of Cardiac Surgery, Institute of Clinical and Experimental Medicine, Prague, Czech Republic; Second Department of Surgery, Department of Cardiovascular Surgery, First Faculty of Medicine, Charles University, Prague, Czech Republic
| |
Collapse
|
32
|
Pieper IL, Friedmann Y, Jones A, Thornton C. Evaluation of Four Veterinary Hematology Analyzers for Bovine and Ovine Blood Counts for In Vitro Testing of Medical Devices. Artif Organs 2016; 40:1054-1061. [PMID: 27087058 DOI: 10.1111/aor.12703] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2015] [Revised: 12/28/2015] [Accepted: 12/30/2015] [Indexed: 01/17/2023]
Abstract
Small affordable automated hematology analyzers that produce rapid and accurate complete blood cell counts are a valuable tool to researchers developing blood-handling medical devices, such as ventricular assist devices, for in vitro safety assessments. In such studies, it is common to use the blood of large animals such as cattle and sheep. However, the commercially available instruments have not been evaluated for their ability to measure the blood counts of these animals. In this study, we compare, for the first time, four veterinary analyzers for blood counts on bovine and ovine blood samples. We look at ease of use, repeatability and agreement with a view to inform researchers of the benefits of these instruments in routine measurement of ovine and bovine bloods during in vitro testing. Complete blood cell counts and a three-part differential (granulocytes, monocytes, and lymphocytes) were measured by each of the instruments, and the results compared to those obtained from two additional analyzers used in a reference laboratory. Repeatability and agreement were evaluated using the Bland-Altman method; bias and 95% limits of agreement between the instruments, and between the instruments and two reference instruments, were used to evaluate instrument performance. In summary, there are advantages and disadvantages with all instruments. Of the four instruments tested, the repeatability and agreement was fairly similar for all instruments except one instrument which cannot be recommended for bovine or ovine blood counts.
Collapse
Affiliation(s)
- Ina Laura Pieper
- Calon Cardio-Technology Ltd, Institute of Life Science, Swansea, United Kingdom
| | - Yasmin Friedmann
- Calon Cardio-Technology Ltd, Institute of Life Science, Swansea, United Kingdom
| | - Alyssa Jones
- Calon Cardio-Technology Ltd, Institute of Life Science, Swansea, United Kingdom
| | - Catherine Thornton
- Calon Cardio-Technology Ltd, Institute of Life Science, Swansea, United Kingdom
| |
Collapse
|
33
|
Microfluidic approaches for the assessment of blood cell trauma: a focus on thrombotic risk in mechanical circulatory support devices. Int J Artif Organs 2016; 39:184-93. [PMID: 27034318 DOI: 10.5301/ijao.5000485] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/03/2016] [Indexed: 11/20/2022]
Abstract
INTRODUCTION Mechanical circulatory support devices (MCSDs) are emerging as a valuable therapeutic option for the management of end-stage heart failure. However, although recipients are routinely administered with anti-thrombotic (AT) drugs, thrombosis persists as a severe post-implant complication. Conventional clinical assays and coagulation markers demonstrate partial ability in preventing the onset of thrombosis. Through years, different laboratory techniques have been proposed as potential tools for the evaluation of platelets' hemostatic response in MCSD recipients. Most rely on platelet aggregation tests; they are performed in static or low shear conditions, neglecting the prominent contribution of MCSD shear-induced mechanical load in enhancing platelet activation (PA). On the other hand, those tests able to account for shear-induced PA have limited possibility of effective clinical translation. AIMS AND METHODS Advances on this side have been addressed by microfluidic technology. Microfluidic devices have been developed for AT drug monitoring under flow, able to replicate physiological and/or constant shear flow conditions in vitro. In this paper, we present a newly developed microfluidic platform able to expose platelets to MCSD-specific dynamic shear stress patterns. We performed in vitro tests circulating human platelets in the microfluidic platform and quantifying the dynamics of PA by means of the Platelet Activity State (PAS) assay. RESULTS Our results prove the feasibility of using microfluidics for the diagnosis of MCSD-related thrombotic risk. This study paves the way for the development of a miniaturized point-of-care device for monitoring AT drug regimen. Such a system may have significant impact on limiting the incidence of thrombosis in MCSD recipients.
Collapse
|
34
|
Bhimaraj A, Uribe C, Suarez EE. Physiological impact of continuous flow on end-organ function: clinical implications in the current era of left ventricular assist devices. Methodist Debakey Cardiovasc J 2015; 11:12-7. [PMID: 25793024 DOI: 10.14797/mdcj-11-1-12] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
The clinical era of continuous-flow left ventricular assist devices has debunked many myths about the dire need of a pulse for human existence. While this therapy has been documented to provide a clear survival benefit in end-stage heart failure patients, we are now faced with certain morbidity challenges that as of yet have no easy mechanistic physiological explanation. The effect of physiological changes on end-organ function in patients supported by continuous-flow ventricular assist devices may offer insight into some of these morbidities. We therefore present a review of current evidence documenting the impact of continuous flow on end-organ function.
Collapse
Affiliation(s)
- Arvind Bhimaraj
- Houston Methodist DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, Texas
| | - Cesar Uribe
- Houston Methodist DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, Texas
| | - Erick E Suarez
- Houston Methodist DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, Texas
| |
Collapse
|
35
|
Dynamic microvesicle release and clearance within the cardiovascular system: triggers and mechanisms. Clin Sci (Lond) 2015; 129:915-31. [PMID: 26359252 DOI: 10.1042/cs20140623] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Interest in cell-derived microvesicles (or microparticles) within cardiovascular diagnostics and therapeutics is rapidly growing. Microvesicles are often measured in the circulation at a single time point. However, it is becoming clear that microvesicle levels both increase and decrease rapidly in response to certain stimuli such as hypoxia, acute cardiac stress, shear stress, hypertriglyceridaemia and inflammation. Consequently, the levels of circulating microvesicles will reflect the balance between dynamic mechanisms for release and clearance. The present review describes the range of triggers currently known to lead to microvesicle release from different cellular origins into the circulation. Specifically, the published data are used to summarize the dynamic impact of these triggers on the degree and rate of microvesicle release. Secondly, a summary of the current understanding of microvesicle clearance via different cellular systems, including the endothelial cell and macrophage, is presented, based on reported studies of clearance in experimental models and clinical scenarios, such as transfusion or cardiac stress. Together, this information can be used to provide insights into potential underlying biological mechanisms that might explain the increases or decreases in circulating microvesicle levels that have been reported and help to design future clinical studies.
Collapse
|
36
|
Abstract
The left ventricular assist device (LVAD) has become an established treatment option for patients with refractory heart failure. Many of these patients experience chronic kidney disease (CKD) due to chronic cardiorenal syndrome type II, which is often alleviated quickly following LVAD implantation. Nevertheless, reversibility of CKD remains difficult to predict. Interestingly, initial recovery of GFR appears to be transient, being followed by gradual but significant late decline. Nevertheless, GFR often remains elevated compared to preimplant status. Larger GFR increases are followed by a proportionally larger late decline. Several explanations for this gradual decline in renal function after LVAD therapy have been proposed, yet a definitive answer remains elusive. Mortality predictors of LVAD implantation are the occurrence of either postimplantation acute kidney injury (AKI) or preimplant CKD. However, patient outcomes continue to improve as LVAD therapy becomes more widespread, and adverse events including AKI appear to decline. In light of a growing destination therapy population, it is important to understand the cumulative effects of long-term LVAD support on kidney function. Additional research and passage of time are required to further unravel the intricate relationships between the LVAD and the kidney.
Collapse
Affiliation(s)
- T R Tromp
- University Medical Center Utrecht, POB 85500, 3508 GA, Utrecht, The Netherlands,
| | | | | |
Collapse
|
37
|
Ferraris VA. Microparticles and endothelial function--A tour de force. J Thorac Cardiovasc Surg 2015; 150:673-4. [PMID: 26162310 DOI: 10.1016/j.jtcvs.2015.06.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2015] [Accepted: 06/04/2015] [Indexed: 10/23/2022]
|
38
|
Massicotte MP, Bauman ME, Murray J, Almond CS. Antithrombotic therapy for ventricular assist devices in children: do we really know what to do? J Thromb Haemost 2015; 13 Suppl 1:S343-50. [PMID: 26149046 DOI: 10.1111/jth.12928] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/31/2023]
Abstract
The use of ventricular assist devices (VADs) in children is increasing. Stroke and device-related thromboembolism remain the most feared complications associated with VAD therapy in children. The presence of a VAD causes dysregulation of hemostasis due to the presence of foreign materials and sheer forces intrinsic to the device resulting in hypercoagulability and potentially life-threatening thrombosis. The use of antithrombotic therapy in adults with VADs modulates this disruption in hemostasis, decreasing the risk of thrombosis. Yet, differences in hemostasis in children (developmental hemostasis) may result in variances in dysregulation by these devices and preclude the use of adult guidelines. Consequently, pediatric device studies must include safety and efficacy estimates of device-specific antithrombotic therapy guidelines. This review will discuss mechanisms of hemostatic dysregulation as it pertains to VADs, goals of VAD antithrombotic therapy for children and adults, and emerging antithrombotic strategies for VAD use in children.
Collapse
Affiliation(s)
- M P Massicotte
- KIDCLOT Pediatric Thrombosis, Stollery Children's Hospital, Edmonton, AB, Canada
- University of Alberta, Edmonton, AB, Canada
| | - M E Bauman
- KIDCLOT Pediatric Thrombosis, Stollery Children's Hospital, Edmonton, AB, Canada
- University of Alberta, Edmonton, AB, Canada
| | - J Murray
- Division of Cardiology, Lucile Packard Children's Hospital Stanford, Stanford, CA, USA
- Stanford University, Stanford, CA, USA
| | - C S Almond
- Division of Cardiology, Lucile Packard Children's Hospital Stanford, Stanford, CA, USA
- Stanford University, Stanford, CA, USA
| |
Collapse
|
39
|
Platelet-derived microparticles generated by neonatal extracorporeal membrane oxygenation systems. ASAIO J 2015; 61:37-42. [PMID: 25303795 DOI: 10.1097/mat.0000000000000164] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Current anticoagulation strategies do not eliminate thromboembolic stroke or limb loss during neonatal extracorporeal membrane oxygenation (ECMO), a form of cardiopulmonary bypass (CPB). In adults, CPB surgery generates prothrombotic platelet-derived microparticles (PMPs), submicron membrane vesicles released from activated platelets. However, information on PMP generation in neonatal ECMO systems is lacking. The objective of this study was to compare PMP generation in five different neonatal ECMO systems, using a simulated circuit with swine blood at 300 ml/min for 4 hours. Systems were composed of both newer components (centrifugal pump and hollow-fiber oxygenator) and traditional components (roller-head pump and silicone membrane oxygenator). Free plasma hemoglobin levels were measured as an indicator of hemolysis and flow cytometry-measured PMP. Hemolysis generated in all ECMO systems was similar to that observed in noncirculated static blood (p = 0.48). There was no difference in net PMP levels between different oxygenators with a given pump. In contrast, net PMP generation in ECMO systems with a centrifugal pump was at least 2.5 times greater than in roller-head pump systems. This was significant when using either a hollow-fiber (p < 0.005) or a silicone membrane (p < 0.05) oxygenator. Future studies are needed to define the relationship between pump-generated PMP and thrombosis.
Collapse
|
40
|
Macrovascular and microvascular function after implantation of left ventricular assist devices in end-stage heart failure: Role of microparticles. J Heart Lung Transplant 2015; 34:921-32. [PMID: 25980571 DOI: 10.1016/j.healun.2015.03.004] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2014] [Revised: 02/08/2015] [Accepted: 03/16/2015] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND The hemodynamic vascular consequences of implanting left ventricular assist devices (LVADs) have not been studied in detail. We investigated the effect of LVAD implantation compared with heart transplant (HTx) on microvascular and macrovascular function in patients with end-stage heart failure and evaluated whether microparticles may play a role in LVAD-related endothelial dysfunction. METHODS Vascular function was assessed in patients with end-stage heart failure awaiting HTx, patients who had undergone implantation of a continuous-flow centrifugal LVAD, and patients who had already received a HTx. Macrovascular function was measured by flow-mediated vasodilation (FMD) using high-resolution ultrasound of the brachial artery. Microvascular function was assessed in the forearm during reactive hyperemia using laser Doppler perfusion imaging and pulsed wave Doppler. Age-matched patients without heart failure and without coronary artery disease (CAD) (healthy control subjects) and patients with stable CAD served as control subjects. Circulating red blood cell (CD253(+)), leukocyte (CD45(+)), platelet (CD31(+)/CD41(+)), and endothelial cell (CD31(+)/CD41(-), CD62e(+), CD144(+)) microparticles were determined by flow cytometry and free hemoglobin by enzyme-linked immunosorbent assay. RESULTS FMD and microvascular function were significantly impaired in patients with end-stage heart failure compared with healthy control subjects and patients with stable CAD. LVAD implantation led to recovery of microvascular function, but not FMD. In parallel, increased free hemoglobin was observed along with red and white cell microparticles and endothelial and platelet microparticles. This finding indicates destruction of blood cells with release of hemoglobin and activation of endothelial cells. HTx and LVAD implantation led to similar improvements in microvascular function. FMD increased and microparticle levels decreased in patients with HTx, whereas shear stress during reactive hyperemia was similar in patients with LVADs and patients with HTx. CONCLUSIONS Our data suggest that LVAD support leads to significant improvements in microvascular perfusion and hemodynamics. However, destruction of blood cells may contribute to residual endothelial dysfunction potentially by increasing nitric oxide scavenging capacity.
Collapse
|
41
|
de Biasi AR, Manning KB, Salemi A. Science for surgeons: understanding pump thrombogenesis in continuous-flow left ventricular assist devices. J Thorac Cardiovasc Surg 2014; 149:667-73. [PMID: 25534307 DOI: 10.1016/j.jtcvs.2014.11.041] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2014] [Revised: 10/28/2014] [Accepted: 11/08/2014] [Indexed: 12/11/2022]
Affiliation(s)
- Andreas R de Biasi
- Department of Cardiothoracic Surgery, Weill Cornell Medical College, New York, NY
| | - Keefe B Manning
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pa; Department of Surgery, Penn State College of Medicine, Hershey, Pa
| | - Arash Salemi
- Department of Cardiothoracic Surgery, Weill Cornell Medical College, New York, NY.
| |
Collapse
|
42
|
IVAK P, PITHA J, WOHLFAHRT P, KRALOVA LESNA I, STAVEK P, DORAZILOVA Z, STEPANKOVA J, MALY J, POKORNY M, NETUKA I. Endothelial Dysfunction Expressed as Endothelial Microparticles in Patients With End-Stage Heart Failure. Physiol Res 2014; 63:S369-73. [DOI: 10.33549/physiolres.932866] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Left ventricular assist devices (LVAD), currently used in treatment of terminal heart failure, are working on principle of rotary pump, which generates continuous blood flow. Non-pulsatile flow is supposed to expose endothelial cells to high stress and potential damage. Therefore, we investigated longitudinal changes in concentration of circulating endothelial microparticles (EMP) as a possible marker of endothelial damage before and after implantation of LVAD. Study population comprised 30 patients with end-stage heart failure indicated for implantation of the Heart Mate II LVAD. Concentrations of microparticles were measured as nanomoles per liter relative to phosphatidylserine before and 3 months after implantation. At 3 months after implantation we observed significant decrease in concentration of EMP [5.89 (95 % CI 4.31-8.03) vs. 3.69 (95 % CI 2.70-5.03), p=0.03] in the whole group; there was no difference observed between patients with ischemic etiology of heart failure (n=18) and with heart failure of non-ischemic etiology (n=12). In addition, heart failure etiology had no effect on the rate of EMP concentration decrease with time. These results indicate possibility that LVAD do not cause vascular damage 3 months after implantation. Whether these results suggest improvement of vascular wall function and of endothelium is to be proved in long-term studies.
Collapse
Affiliation(s)
| | - J. PITHA
- Laboratory for Atherosclerosis Research, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Shah KB, Kontos MC. Microparticles and left ventricular assist device complications: A causal association? J Heart Lung Transplant 2014; 33:468-9. [DOI: 10.1016/j.healun.2014.02.031] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2014] [Revised: 02/13/2014] [Accepted: 02/13/2014] [Indexed: 02/02/2023] Open
|