1
|
Guérit F, Middlebrooks JC, Richardson ML, Arneja A, Harland AJ, Gransier R, Wouters J, Carlyon RP. Tonotopic Selectivity in Cats and Humans: Electrophysiology and Psychophysics. J Assoc Res Otolaryngol 2022; 23:513-534. [PMID: 35697952 PMCID: PMC9437197 DOI: 10.1007/s10162-022-00851-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Accepted: 05/02/2022] [Indexed: 01/06/2023] Open
Abstract
We describe a scalp-recorded measure of tonotopic selectivity, the "cortical onset response" (COR) and compare the results between humans and cats. The COR results, in turn, were compared with psychophysical masked-detection thresholds obtained using similar stimuli and obtained from both species. The COR consisted of averaged responses elicited by 50-ms tone-burst probes presented at 1-s intervals against a continuous noise masker. The noise masker had a bandwidth of 1 or 1/8th octave, geometrically centred on 4000 Hz for humans and on 8000 Hz for cats. The probe frequency was either - 0.5, - 0.25, 0, 0.25 or 0.5 octaves re the masker centre frequency. The COR was larger for probe frequencies more distant from the centre frequency of the masker, and this effect was greater for the 1/8th-octave than for the 1-octave masker. This pattern broadly reflected the masked excitation patterns obtained psychophysically with similar stimuli in both species. However, the positive signal-to-noise ratio used to obtain reliable COR measures meant that some aspects of the data differed from those obtained psychophysically, in a way that could be partly explained by the upward spread of the probe's excitation pattern. Our psychophysical measurements also showed that the auditory filter width obtained at 8000 Hz using notched-noise maskers was slightly wider in cat than previous measures from humans. We argue that although conclusions from COR measures differ in some ways from conclusions based on psychophysics, the COR measures provide an objective, noninvasive, valid measure of tonotopic selectivity that does not require training and that may be applied to acoustic and cochlear-implant experiments in humans and laboratory animals.
Collapse
Affiliation(s)
- Francois Guérit
- grid.5335.00000000121885934Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| | - John C. Middlebrooks
- grid.266093.80000 0001 0668 7243Department of Otolaryngology, University of California at Irvine, Irvine, CA USA
- grid.266093.80000 0001 0668 7243Department of Neurobiology and Behavior, University of California at Irvine, Irvine, CA USA
- grid.266093.80000 0001 0668 7243Department of Cognitive Sciences, University of California at Irvine, Irvine, CA USA
- grid.266093.80000 0001 0668 7243Department of Biomedical Engineering, University of California at Irvine, Irvine, CA USA
| | - Matthew L. Richardson
- grid.266093.80000 0001 0668 7243Department of Otolaryngology, University of California at Irvine, Irvine, CA USA
| | - Akshat Arneja
- grid.266093.80000 0001 0668 7243Department of Cognitive Sciences, University of California at Irvine, Irvine, CA USA
| | - Andrew J. Harland
- grid.5335.00000000121885934Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| | - Robin Gransier
- Dept. of Neurosciences, ExpORL, Leuven, Louvain, KU Belgium
| | - Jan Wouters
- Dept. of Neurosciences, ExpORL, Leuven, Louvain, KU Belgium
| | - Robert P. Carlyon
- grid.5335.00000000121885934Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| |
Collapse
|
2
|
Carlyon RP, Goehring T. Cochlear Implant Research and Development in the Twenty-first Century: A Critical Update. J Assoc Res Otolaryngol 2021; 22:481-508. [PMID: 34432222 PMCID: PMC8476711 DOI: 10.1007/s10162-021-00811-5] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 08/02/2021] [Indexed: 12/22/2022] Open
Abstract
Cochlear implants (CIs) are the world's most successful sensory prosthesis and have been the subject of intense research and development in recent decades. We critically review the progress in CI research, and its success in improving patient outcomes, from the turn of the century to the present day. The review focuses on the processing, stimulation, and audiological methods that have been used to try to improve speech perception by human CI listeners, and on fundamental new insights in the response of the auditory system to electrical stimulation. The introduction of directional microphones and of new noise reduction and pre-processing algorithms has produced robust and sometimes substantial improvements. Novel speech-processing algorithms, the use of current-focusing methods, and individualised (patient-by-patient) deactivation of subsets of electrodes have produced more modest improvements. We argue that incremental advances have and will continue to be made, that collectively these may substantially improve patient outcomes, but that the modest size of each individual advance will require greater attention to experimental design and power. We also briefly discuss the potential and limitations of promising technologies that are currently being developed in animal models, and suggest strategies for researchers to collectively maximise the potential of CIs to improve hearing in a wide range of listening situations.
Collapse
Affiliation(s)
- Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK.
| | - Tobias Goehring
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK
| |
Collapse
|
3
|
Jiang C, Singhal S, Landry T, Roberts I, de Rijk S, Brochier T, Goehring T, Tam Y, Carlyon R, Malliaras G, Bance M. An Instrumented Cochlea Model for the Evaluation of Cochlear Implant Electrical Stimulus Spread. IEEE Trans Biomed Eng 2021; 68:2281-2288. [PMID: 33587694 PMCID: PMC8215857 DOI: 10.1109/tbme.2021.3059302] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Cochlear implants use electrical stimulation of the auditory nerve to restore the sensation of hearing to deaf people. Unfortunately, the stimulation current spreads extensively within the cochlea, resulting in “blurring” of the signal, and hearing that is far from normal. Current spread can be indirectly measured using the implant electrodes for both stimulating and sensing, but this provides incomplete information near the stimulating electrode due to electrode-electrolyte interface effects. Here, we present a 3D-printed “unwrapped” physical cochlea model with integrated sensing wires. We integrate resistors into the walls of the model to simulate current spread through the cochlear bony wall, and “tune” these resistances by calibration with an in-vivo electrical measurement from a cochlear implant patient. We then use this model to compare electrical current spread under different stimulation modes including monopolar, bipolar and tripolar configurations. Importantly, a trade-off is observed between stimulation amplitude and current focusing among different stimulation modes. By combining different stimulation modes and changing intracochlear current sinking configurations in the model, we explore this trade-off between stimulation amplitude and focusing further. These results will inform clinical strategies for use in delivering speech signals to cochlear implant patients.
Collapse
|
4
|
McKay CM. Applications of Phenomenological Loudness Models to Cochlear Implants. Front Psychol 2021; 11:611517. [PMID: 33519626 PMCID: PMC7838155 DOI: 10.3389/fpsyg.2020.611517] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Accepted: 12/11/2020] [Indexed: 11/13/2022] Open
Abstract
Cochlear implants electrically stimulate surviving auditory neurons in the cochlea to provide severely or profoundly deaf people with access to hearing. Signal processing strategies derive frequency-specific information from the acoustic signal and code amplitude changes in frequency bands onto amplitude changes of current pulses emitted by the tonotopically arranged intracochlear electrodes. This article first describes how parameters of the electrical stimulation influence the loudness evoked and then summarizes two different phenomenological models developed by McKay and colleagues that have been used to explain psychophysical effects of stimulus parameters on loudness, detection, and modulation detection. The Temporal Model is applied to single-electrode stimuli and integrates cochlear neural excitation using a central temporal integration window analogous to that used in models of normal hearing. Perceptual decisions are made using decision criteria applied to the output of the integrator. By fitting the model parameters to a variety of psychophysical data, inferences can be made about how electrical stimulus parameters influence neural excitation in the cochlea. The Detailed Model is applied to multi-electrode stimuli, and includes effects of electrode interaction at a cochlear level and a transform between integrated excitation and specific loudness. The Practical Method of loudness estimation is a simplification of the Detailed Model and can be used to estimate the relative loudness of any multi-electrode pulsatile stimuli without the need to model excitation at the cochlear level. Clinical applications of these models to novel sound processing strategies are described.
Collapse
Affiliation(s)
- Colette M. McKay
- Bionics Institute, Melbourne, VIC, Australia
- Department of Medical Bionics, University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|
5
|
Jiang C, de Rijk SR, Malliaras GG, Bance ML. Electrochemical impedance spectroscopy of human cochleas for modeling cochlear implant electrical stimulus spread. APL MATERIALS 2020; 8:091102. [PMID: 32929397 PMCID: PMC7470452 DOI: 10.1063/5.0012514] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 08/14/2020] [Indexed: 05/07/2023]
Abstract
Cochlear implants (CIs) have tremendously helped people with severe to profound hearing loss to gain access to sound and oral-verbal communication. However, the electrical stimulus in the cochlea spreads easily and widely, since the perilymph and endolymph (i.e., intracochlear fluids) are essentially electrolytes, leading to an inability to focus stimulation to discrete portions of the auditory nerve, which blurs the neural signal. Here, we characterize the complex transimpedances of human cadaveric cochleas to investigate how electrical stimulus spread is distributed from 10 Hz to 100 kHz. By using electrochemical impedance spectroscopy (EIS), both the resistive and capacitive elements of human cochleas are measured and modeled with an electrical circuit model, identifying spread-induced and spread-independent impedance components. Based on this electrical circuit model, we implement a Laplace transform to simulate the theoretical shapes of the spread signals. The model is validated by experimentally applying the simulated stimulus as a real stimulus to the cochlea and measuring the shapes of the spread signals, with relative errors of <0.6% from the model. Based on this model, we show the relationship between stimulus pulse duration and electrical stimulus spread. This EIS technique to characterize the transimpedances of human cochleas provides a new way to predict the spread signal under an arbitrary electrical stimulus, thus providing preliminary guidance to the design of CI stimuli for different CI users and coding strategies.
Collapse
Affiliation(s)
| | - S. R. de Rijk
- Department of Clinical Neurosciences, University
of Cambridge, Cambridge CB2 0AH, United Kingdom
| | - G. G. Malliaras
- Division of Electrical Engineering, Department of
Engineering, University of Cambridge, Cambridge CB3 0FA, United
Kingdom
- Authors to whom correspondence should be addressed:
and
| | - M. L. Bance
- Authors to whom correspondence should be addressed:
and
| |
Collapse
|
6
|
Zhou N, Zhu Z, Dong L, Galvin JJ. Effect of pulse phase duration on forward masking and spread of excitation in cochlear implant listeners. PLoS One 2020; 15:e0236179. [PMID: 32687516 PMCID: PMC7371170 DOI: 10.1371/journal.pone.0236179] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 06/30/2020] [Indexed: 11/18/2022] Open
Abstract
Previous cochlear implant (CI) research has shown that at a pulse train with a long pulse phase duration (PPD) requires less current but greater charge to obtain the same loudness as a pulse train with a short PPD. This might result in different excitation patterns between long and short PPDs. At equal loudness, long PPDs might produce greater masking due to greater charge. However, because they require less current, long PPDs may produce a smaller spatial spread of excitation (SOE) compared to short PPDs by evoking a greater neural firing probability within the relatively small current field. To investigate the effects of PPD on excitation patterns, overall masking and SOE were compared for equally loud stimuli with short or long PPD in 10 adult CI ears. Forward masking patterns were measured at relatively soft, medium, and loud presentation levels. Threshold shifts were calculated in terms of percent dynamic range (DR) of the probe. The area under the curve (AUC) of the masking functions was significantly larger for the long PPD than for the short PPD masker. The difference in AUC was proportional to the difference in charge between the short and long PPD maskers. To estimate SOE, the masking patterns were first normalized to the peak masking, and then AUC was calculated. SOE was significantly larger for the short PPD than for the long PPD masker. Thus, at equal loudness, long PPDs produced greater overall masking (possibly due to greater charge) but less SOE (possibly due to less current spread) than did short PPDs. The effect of the interaction between masking and SOE by long PPD stimulation remains to be tested.
Collapse
Affiliation(s)
- Ning Zhou
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina, United States of America
| | - Zhen Zhu
- Department of Engineering, East Carolina University, Greenville, North Carolina, United States of America
| | - Lixue Dong
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina, United States of America
| | - John J. Galvin
- House Ear Institute, Los Angeles, California, United States of America
- * E-mail:
| |
Collapse
|
7
|
Forward masking patterns by low and high-rate stimulation in cochlear implant users: Differences in masking effectiveness and spread of neural excitation. Hear Res 2020; 389:107921. [PMID: 32097828 DOI: 10.1016/j.heares.2020.107921] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 01/15/2020] [Accepted: 02/13/2020] [Indexed: 11/20/2022]
Abstract
The goal of the present study was to compare forward masking patterns by stimulation of low and high rates in cochlear implant users. Postlingually deafened Cochlear Nucleus® device users participated in the study. In experiment 1, two maskers of different rates (250 and 1000 pulses per second) were set at levels that produced equal masking for a probe presented at the same electrode as the maskers. This aligned the two masking functions at the on-site probe location. Then their forward masking patterns for the far probes were compared. Results showed that slope of the masked probe-threshold decay as a function of probe-masker separation was steeper for the high-rate than the low-rate masker. A linear model indicated that this difference in spread of neural excitation (SOE) was accounted for by two factors that were not correlated with each other. One factor was that the low-rate masker required a considerably higher current level to be equally effective in masking as the high-rate masker. The second factor was the effect of stimulation rate on loudness, i.e., integration of multiple pulses. This was consistent with our hypothesis that if an increase in stimulation rate does not result in an increased total neural response, then it is unlikely that the change in rate would change spatial distribution of the neural activity. Interestingly, the difference in masking effectiveness of the maskers predicted subjects' speech recognition. Poorer performers were those who showed more comparable masking effects by maskers of different rates. The difference in the masking effectiveness may indirectly measure the auditory neurons' excitability, which predicts speech recognition. In experiment 2, SOE of the high-rate and low-rate maskers were compared at a level that is clinically relevant, i.e., equal loudness. At equal loudness, high-rate stimulation not only produced an overall greater amount of forward masking, but also a shallower decay of masking with probe-masker separation (wider SOE), compared to low rate. The difference in SOE was the opposite to the findings from experiment 1. Whether the maskers were calibrated for equal masking or loudness, the absolute current level was always higher for the low-rate masker, which suggests that the SOE patterns cannot be explained by current spread alone. The fact that high-rate stimulation produced greater masking and wider SOE at equal loudness may explain why using high stimulation rates has not produced consistent benefits for speech recognition, and why lowering stimulation rate from the manufacturer's default sometimes results in improved speech recognition for subjects.
Collapse
|
8
|
Lyu Q, Lu Z, Li H, Qiu S, Guo J, Sui X, Sun P, Li L, Chai X, Lovell NH. A Three-Dimensional Microelectrode Array to Generate Virtual Electrodes for Epiretinal Prosthesis Based on a Modeling Study. Int J Neural Syst 2020; 30:2050006. [DOI: 10.1142/s0129065720500069] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Despite many advances in the development of retinal prostheses, clinical reports show that current retinal prosthesis subjects can only perceive prosthetic vision with poor visual acuity. A possible approach for improving visual acuity is to produce virtual electrodes (VEs) through electric field modulation. Generating controllable and localized VEs is a crucial factor in effectively improving the perceptive resolution of the retinal prostheses. In this paper, we aimed to design a microelectrode array (MEA) that can produce converged and controllable VEs by current steering stimulation strategies. Through computational modeling, we designed a three-dimensional concentric ring–disc MEA and evaluated its performance with different stimulation strategies. Our simulation results showed that electrode–retina distance (ERD) and inter-electrode distance (IED) can dramatically affect the distribution of electric field. Also the converged VEs could be produced when the parameters of the three-dimensional MEA were appropriately set. VE sites can be controlled by manipulating the proportion of current on each adjacent electrode in a current steering group (CSG). In addition, spatial localization of electrical stimulation can be greatly improved under quasi-monopolar (QMP) stimulation. This study may provide support for future application of VEs in epiretinal prosthesis for potentially increasing the visual acuity of prosthetic vision.
Collapse
Affiliation(s)
- Qing Lyu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Zhuofan Lu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Heng Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Shirong Qiu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Jiahui Guo
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Xiaohong Sui
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Pengcheng Sun
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Liming Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Xinyu Chai
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Nigel H. Lovell
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| |
Collapse
|
9
|
de Jong MAM, Briaire JJ, van der Woude SFS, Frijns JHM. Dynamic current focusing for loudness encoding in cochlear implants: a take-home trial. Int J Audiol 2019; 58:553-564. [PMID: 31012768 DOI: 10.1080/14992027.2019.1601270] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Objective: This study aimed to evaluate a more energy-efficient dynamic current focussing (DCF) speech-processing strategy after long-term listening experience. In DCF, tripolar stimulation is used near the threshold and loudness is controlled by the compensation coefficient σ. A recent acute pilot study showed improved spectral-temporally modulated ripple test (SMRT) scores at low loudness levels, but battery life was reduced to 1.5-4 hours. Design: Within-subject comparisons were made for the clinical versus. DCF strategy after 5 weeks of at-home usage. Speech intelligibility in noise, spectral ripple discrimination, temporal modulation detection, loudness growth, and subjective ratings were assessed. Study sample: Twenty HiRes90K (Advanced Bionics, Valencia, USA) cochlear implant (CI) users. Results: Average battery life was 9 hours with the newly implemented DCF compared to 13.4 hours with the clinical strategy. Compared with measurements made at the beginning of the study, SMRT-scores and speech intelligibility in noise were significantly improved with DCF. However, both measures suffered from unexpected learning effects over time. The improvement disappeared and speech intelligibility in noise declined significantly relative to the final control measurement with the clinical strategy. Conclusion: Most CI users can adapt to the DCF strategy in a take-home setting. Although DCF has the potential to improve performance on the SMRT test, learning effects complicate the interpretation of the current results.
Collapse
Affiliation(s)
- Monique A M de Jong
- a Department of Otorhinolaryngology and Head and Neck Surgery , Leiden University Medical Center , Leiden , the Netherlands
| | - Jeroen J Briaire
- a Department of Otorhinolaryngology and Head and Neck Surgery , Leiden University Medical Center , Leiden , the Netherlands
| | - Séline F S van der Woude
- a Department of Otorhinolaryngology and Head and Neck Surgery , Leiden University Medical Center , Leiden , the Netherlands
| | - Johan H M Frijns
- a Department of Otorhinolaryngology and Head and Neck Surgery , Leiden University Medical Center , Leiden , the Netherlands.,b Leiden Institute for Brain and Cognition, Leiden University , Leiden , the Netherlands
| |
Collapse
|
10
|
Xu Y, Xia N, Lim M, Tan X, Tran MH, Boulger E, Peng F, Young H, Rau C, Rack A, Richter CP. Multichannel optrodes for photonic stimulation. NEUROPHOTONICS 2018; 5:045002. [PMID: 30397630 PMCID: PMC6197865 DOI: 10.1117/1.nph.5.4.045002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Accepted: 09/24/2018] [Indexed: 05/27/2023]
Abstract
An emerging method in the field of neural stimulation is the use of photons to activate neurons. The possible advantage of optical stimulation over electrical is attributable to its spatially selective activation of small neuron populations, which is promising in generating superior spatial resolution in neural interfaces. Two principal methods are explored for cochlear prostheses: direct stimulation of nerves with infrared light and optogenetics. This paper discusses basic requirements for developing a light delivery system (LDS) for the cochlea and provides examples for building such devices. The proposed device relies on small optical sources, which are assembled in an array to be inserted into the cochlea. The mechanical properties, the biocompatibility, and the efficacy of optrodes have been tested in animal models. The force required to insert optrodes into a model of the human scala tympani was comparable to insertion forces obtained for contemporary cochlear implant electrodes. Side-emitting diodes are powerful enough to evoke auditory responses in guinea pigs. Chronic implantation of the LDS did not elevate auditory brainstem responses over 26 weeks.
Collapse
Affiliation(s)
- Yingyue Xu
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
- Northwestern University, Department of Communication Sciences and Disorders, Evanston, Illinois, United States
| | - Nan Xia
- Qingdao University, Institute for Digital Medicine and Computer-assisted Surgery, Qingdao, China
| | - Michelle Lim
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
| | - Xiaodong Tan
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
| | - Minh Ha Tran
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
| | - Erin Boulger
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
| | - Fei Peng
- Chongqing University, Bioengineering College, Chongqing, China
| | - Hunter Young
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
| | - Christoph Rau
- Diamond Light Source Ltd., Diamond House, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom
| | - Alexander Rack
- Structure of Materials Group-ID19, European Synchrotron Radiation Facility, Cedex 9, France
| | - Claus-Peter Richter
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
- Northwestern University, Department of Communication Sciences and Disorders, Evanston, Illinois, United States
- Northwestern University, Department of Biomedical Engineering, Evanston, Illinois, United States
- Northwestern University, Hugh Knowles Center for Clinical and Basic Sciences in Hearing, Evanston, Illinois, United States
| |
Collapse
|
11
|
DeVries L, Arenberg JG. Psychophysical Tuning Curves as a Correlate of Electrode Position in Cochlear Implant Listeners. J Assoc Res Otolaryngol 2018; 19:571-587. [PMID: 29869047 DOI: 10.1007/s10162-018-0678-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Accepted: 05/23/2018] [Indexed: 01/04/2023] Open
Abstract
Speech understanding abilities vary widely among cochlear implant (CI) listeners. A potential source of this variability is the electrode-neuron interface (ENI), which includes peripheral factors such as electrode position and integrity of remaining spiral ganglion neurons. Suboptimal positioning of the electrode array has been associated with poorer speech outcomes; however, postoperative computerized tomography (CT) scans are often not available to clinicians. CT-estimated electrode-to-modiolus distance (distance from the inner wall of the cochlea) has been shown to account for some variability in behavioral thresholds. However, psychophysical tuning curves (PTCs) may provide additional insight into site-specific variation in channel interaction. Thirteen unilaterally implanted adults with the Advanced Bionics HiRes90K device participated. Behavioral thresholds and PTCs were collected for all available electrodes with steered quadrupolar (sQP) configuration, using a modified threshold sweep procedure, used in Bierer et al. (Trends Hear 19:1-12, 2015). PTC bandwidths were quantified to characterize channel interaction across the electrode array, and tip shifts were assessed to identify possible contributions of neural dead regions. Broader PTC bandwidths were correlated with electrodes farther from the modiolus, but not correlated with sQP threshold, though a trend was observed. Both measures were affected by scalar location, and PTC tip shifts were observed for electrodes farther from the modiolus. sQP threshold was the only variable correlated with word recognition. These results suggest PTCs may be used as a site-specific measure of channel interaction that correlates with electrode position in some CI listeners.
Collapse
Affiliation(s)
- Lindsay DeVries
- Department of Speech and Hearing Sciences, University of Washington, 4131 15th Ave NE, Seattle, WA, 98106, USA.
| | - Julie G Arenberg
- Department of Speech and Hearing Sciences, University of Washington, 4131 15th Ave NE, Seattle, WA, 98106, USA
| |
Collapse
|
12
|
Lee DH, Aronoff JM. Changing stimulation patterns can change the broadness of contralateral masking functions for bilateral cochlear implant users. Hear Res 2018; 363:55-61. [PMID: 29548706 DOI: 10.1016/j.heares.2018.03.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Revised: 02/19/2018] [Accepted: 03/02/2018] [Indexed: 11/29/2022]
Abstract
Past studies have found that contralateral masking functions are sharper than ipsilateral masking functions for cochlear implant (CI) users. This could suggest that contralateral masking effects are only sensitive to the peak of the masker stimulation for this population. To determine if that is the case, this study investigated whether using broader stimulation patterns affects the broadness of the contralateral masking function. Contralateral masking functions were measured for six bilateral CI users using both a broad and narrow masker. Findings from this study revealed that the broad masker resulted in a broader contralateral masking function. This would suggest that stimulation outside of the peak of the masker affects contralateral masking functions for CI users.
Collapse
Affiliation(s)
- Daniel H Lee
- Department of Speech and Hearing Science, University of Illinois at Urbana-Champaign, 901 S. 6th St., Champaign, IL 61820, USA.
| | - Justin M Aronoff
- Department of Speech and Hearing Science, University of Illinois at Urbana-Champaign, 901 S. 6th St., Champaign, IL 61820, USA.
| |
Collapse
|
13
|
DeVries L, Arenberg JG. Current Focusing to Reduce Channel Interaction for Distant Electrodes in Cochlear Implant Programs. Trends Hear 2018; 22:2331216518813811. [PMID: 30488764 PMCID: PMC6277758 DOI: 10.1177/2331216518813811] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2018] [Revised: 10/17/2018] [Accepted: 10/26/2018] [Indexed: 11/17/2022] Open
Abstract
Speech understanding abilities are highly variable among cochlear implant (CI) listeners. Poor electrode-neuron interfaces (ENIs) caused by sparse neural survival or distant electrode placement may lead to increased channel interaction and reduced speech perception. Currently, it is not possible to directly measure neural survival in CI listeners; therefore, obtaining information about electrode position is an alternative approach to assessing ENIs. This information can be estimated with computerized tomography (CT) imaging; however, postoperative CT imaging is not often available. A reliable method to assess channel interaction, such as the psychophysical tuning curve (PTC), offers an alternative way to identify poor ENIs. This study aimed to determine (a) the within-subject relationship between CT-estimated electrode distance and PTC bandwidths, and (b) whether using focused stimulation on channels with suspected poor ENI improves vowel identification and sentence recognition. In 13 CI listeners, CT estimates of electrode-to-modiolus distance and PTCs bandwidths were measured for all available electrodes. Two test programs were created, wherein a subset of electrodes used focused stimulation based on (a) broad PTC bandwidth (Tuning) and (b) far electrode-to-modiolus distance (Distance). Two control programs were also created: (a) Those channels not focused in the Distance program (Inverse-Control), and (b) an all-channel monopolar program (Monopolar-Control). Across subjects, scores on the Distance and Tuning programs were significantly higher than the Inverse-Control program, and similar to the Monopolar-Control program. Subjective ratings were similar for all programs. These findings suggest that focusing channels suspected to have a high degree of channel interaction result in quite different outcomes, acutely.
Collapse
Affiliation(s)
- Lindsay DeVries
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA
| | - Julie G. Arenberg
- Department of Speech and Hearing Sciences, University of Washington, Seattle, WA, USA
| |
Collapse
|
14
|
Carlyon RP, Deeks JM, Undurraga J, Macherey O, van Wieringen A. Spatial Selectivity in Cochlear Implants: Effects of Asymmetric Waveforms and Development of a Single-Point Measure. J Assoc Res Otolaryngol 2017; 18:711-727. [PMID: 28755309 PMCID: PMC5612920 DOI: 10.1007/s10162-017-0625-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Accepted: 05/05/2017] [Indexed: 01/07/2023] Open
Abstract
Three experiments studied the extent to which cochlear implant users' spatial selectivity can be manipulated using asymmetric waveforms and tested an efficient method for comparing spatial selectivity produced by different stimuli. Experiment 1 measured forward-masked psychophysical tuning curves (PTCs) for a partial tripolar (pTP) probe. Maskers were presented on bipolar pairs separated by one unused electrode; waveforms were either symmetric biphasic ("SYM") or pseudomonophasic with the short high-amplitude phase being either anodic ("PSA") or cathodic ("PSC") on the more apical electrode. For the SYM masker, several subjects showed PTCs consistent with a bimodal excitation pattern, with discrete excitation peaks on each electrode of the bipolar masker pair. Most subjects showed significant differences between the PSA and PSC maskers consistent with greater masking by the electrode where the high-amplitude phase was anodic, but the pattern differed markedly across subjects. Experiment 2 measured masked excitation patterns for a pTP probe and either a monopolar symmetric biphasic masker ("MP_SYM") or pTP pseudomonophasic maskers where the short high-amplitude phase was either anodic ("TP_PSA") or cathodic ("TP_PSC") on the masker's central electrode. Four of the five subjects showed significant differences between the masker types, but again the pattern varied markedly across subjects. Because the levels of the maskers were chosen to produce the same masking of a probe on the same channel as the masker, it was correctly predicted that maskers that produce broader masking patterns would sound louder. Experiment 3 exploited this finding by using a single-point measure of spread of excitation to reveal significantly better spatial selectivity for TP_PSA compared to TP_PSC maskers.
Collapse
Affiliation(s)
- Robert P Carlyon
- MRC Cognition and Brain Sciences Unit, 15 Chaucer Rd, Cambridge, CB1 3DA, UK
| | - John M Deeks
- MRC Cognition and Brain Sciences Unit, 15 Chaucer Rd, Cambridge, CB1 3DA, UK.
| | - Jaime Undurraga
- ExpORL, Department of Neurosciences, KULeuven, Herestraat 49 bus 721, 3000, Leuven, Belgium
| | - Olivier Macherey
- MRC Cognition and Brain Sciences Unit, 15 Chaucer Rd, Cambridge, CB1 3DA, UK
- LMA-CNRS, UPR 7051, Aix-Marseille University, Centrale Marseille, 4, Impasse Nikola Tesla, CS40006, 13453, Marseille Cedex 13, France
| | - Astrid van Wieringen
- ExpORL, Department of Neurosciences, KULeuven, Herestraat 49 bus 721, 3000, Leuven, Belgium
| |
Collapse
|
15
|
Comparison of Multipole Stimulus Configurations With Respect to Loudness and Spread of Excitation. Ear Hear 2017; 38:487-496. [DOI: 10.1097/aud.0000000000000416] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
16
|
Padilla M, Stupak N, Landsberger DM. Pitch ranking with different virtual channel configurations in electrical hearing. Hear Res 2017; 348:54-62. [DOI: 10.1016/j.heares.2017.02.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2016] [Revised: 02/09/2017] [Accepted: 02/14/2017] [Indexed: 11/29/2022]
|
17
|
Abstract
Recent advances in deep brain stimulators and brain-machine interfaces have greatly expanded the possibilities of neuroprosthetics and neuromodulation. Together with advances in neuroengineering, nanotechnology, molecular biology and material sciences, it is now possible to address fundamental questions in neuroscience in new, more powerful ways. It is now possible to apply these new technologies in ways that range from augmenting and restoring function to neuromodulation modalities that treat neuropsychiatric disorders. Recent developments in neuromodulation methods offer significant advantages and potential clinical benefits for a variety of disorders. Here we describe the current state of the art in neuromodulation methods, and some advances in brain-machine interfaces, describing the advantages and limitations of the clinical applications of each method. The future applications of these new methods and how they will shape the future of psychiatry and medicine, along with safety and ethical implications, are also discussed.
Collapse
Affiliation(s)
| | - Ricardo Ewbank Steffen
- Rio de Janeiro State University (UERJ), Institute of Social Medicine, Department of Health Policy and Management.
| |
Collapse
|
18
|
George SS, Shivdasani MN, Fallon JB. Effect of current focusing on the sensitivity of inferior colliculus neurons to amplitude-modulated stimulation. J Neurophysiol 2016; 116:1104-16. [PMID: 27306672 DOI: 10.1152/jn.00126.2016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2016] [Accepted: 06/15/2016] [Indexed: 11/22/2022] Open
Abstract
In multichannel cochlear implants (CIs), current is delivered to specific electrodes along the cochlea in the form of amplitude-modulated pulse trains, to convey temporal and spectral cues. Our previous studies have shown that focused multipolar (FMP) and tripolar (TP) stimulation produce more restricted neural activation and reduced channel interactions in the inferior colliculus (IC) compared with traditional monopolar (MP) stimulation, suggesting that focusing of stimulation could produce better transmission of spectral information. The present study explored the capability of IC neurons to detect modulated CI stimulation with FMP and TP stimulation compared with MP stimulation. The study examined multiunit responses of IC neurons in acutely deafened guinea pigs by systematically varying the stimulation configuration, modulation depth, and stimulation level. Stimuli were sinusoidal amplitude-modulated pulse trains (carrier rate of 120 pulses/s). Modulation sensitivity was quantified by measuring modulation detection thresholds (MDTs), defined as the lowest modulation depth required to differentiate the response of a modulated stimulus from an unmodulated one. Whereas MP stimulation showed significantly lower MDTs than FMP and TP stimulation (P values <0.05) at stimulation ≤2 dB above threshold, all stimulation configurations were found to have similar modulation sensitivities at 4 dB above threshold. There was no difference found in modulation sensitivity between FMP and TP stimulation. The present study demonstrates that current focusing techniques such as FMP and TP can adequately convey amplitude modulation and are comparable to MP stimulation, especially at higher stimulation levels, although there may be some trade-off between spectral and temporal fidelity with current focusing stimulation.
Collapse
Affiliation(s)
- Shefin S George
- The Bionics Institute, East Melbourne, Australia; and Department of Medical Bionics, University of Melbourne, Melbourne, Australia
| | - Mohit N Shivdasani
- The Bionics Institute, East Melbourne, Australia; and Department of Medical Bionics, University of Melbourne, Melbourne, Australia
| | - James B Fallon
- The Bionics Institute, East Melbourne, Australia; and Department of Medical Bionics, University of Melbourne, Melbourne, Australia
| |
Collapse
|
19
|
Abstract
OBJECTIVES This study measured the impact of auditory spectral resolution on listening effort. Systematic degradation in spectral resolution was hypothesized to elicit corresponding systematic increases in pupil dilation, consistent with the notion of pupil dilation as a marker of cognitive load. DESIGN Spectral resolution of sentences was varied with two different vocoders: (1) a noise-channel vocoder with a variable number of spectral channels; and (2) a vocoder designed to simulate front-end processing of a cochlear implant, including peak-picking channel selection with variable synthesis filter slopes to simulate spread of neural excitation. Pupil dilation was measured after subject-specific luminance adjustment and trial-specific baseline measures. Mixed-effects growth curve analysis was used to model pupillary responses over time. RESULTS For both types of vocoder, pupil dilation grew with each successive degradation in spectral resolution. Within each condition, pupillary responses were not related to intelligibility scores, and the effect of spectral resolution on pupil dilation persisted even when only analyzing trials in which responses were 100% correct. CONCLUSIONS Intelligibility scores alone were not sufficient to quantify the effort required to understand speech with poor resolution. Degraded spectral resolution results in increased effort required to understand speech, even when intelligibility is at 100%. Pupillary responses were a sensitive and highly granular measurement to reveal changes in listening effort. Pupillary responses might potentially reveal the benefits of aural prostheses that are not captured by speech intelligibility performance alone as well as the disadvantages that are overcome by increased listening effort.
Collapse
|
20
|
DeVries L, Scheperle R, Bierer JA. Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral Thresholds. J Assoc Res Otolaryngol 2016; 17:237-52. [PMID: 26926152 DOI: 10.1007/s10162-016-0557-9] [Citation(s) in RCA: 93] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Accepted: 02/04/2016] [Indexed: 11/26/2022] Open
Abstract
Variability in speech perception scores among cochlear implant listeners may largely reflect the variable efficacy of implant electrodes to convey stimulus information to the auditory nerve. In the present study, three metrics were applied to assess the quality of the electrode-neuron interface of individual cochlear implant channels: the electrically evoked compound action potential (ECAP), the estimation of electrode position using computerized tomography (CT), and behavioral thresholds using focused stimulation. The primary motivation of this approach is to evaluate the ECAP as a site-specific measure of the electrode-neuron interface in the context of two peripheral factors that likely contribute to degraded perception: large electrode-to-modiolus distance and reduced neural density. Ten unilaterally implanted adults with Advanced Bionics HiRes90k devices participated. ECAPs were elicited with monopolar stimulation within a forward-masking paradigm to construct channel interaction functions (CIF), behavioral thresholds were obtained with quadrupolar (sQP) stimulation, and data from imaging provided estimates of electrode-to-modiolus distance and scalar location (scala tympani (ST), intermediate, or scala vestibuli (SV)) for each electrode. The width of the ECAP CIF was positively correlated with electrode-to-modiolus distance; both of these measures were also influenced by scalar position. The ECAP peak amplitude was negatively correlated with behavioral thresholds. Moreover, subjects with low behavioral thresholds and large ECAP amplitudes, averaged across electrodes, tended to have higher speech perception scores. These results suggest a potential clinical role for the ECAP in the objective assessment of individual cochlear implant channels, with the potential to improve speech perception outcomes.
Collapse
Affiliation(s)
- Lindsay DeVries
- Department of Speech and Hearing Sciences, University of Washington, 4131 15th Ave NE, Seattle, WA, 98105, USA.
| | - Rachel Scheperle
- Department of Communication Sciences and Disorders, Wendell Johnson Speech and Hearing Center, University of Iowa, Iowa City, Iowa, 52242, USA
| | - Julie Arenberg Bierer
- Department of Speech and Hearing Sciences, University of Washington, 4131 15th Ave NE, Seattle, WA, 98105, USA
| |
Collapse
|
21
|
Padilla M, Landsberger DM. Reduction in spread of excitation from current focusing at multiple cochlear locations in cochlear implant users. Hear Res 2016; 333:98-107. [PMID: 26778546 DOI: 10.1016/j.heares.2016.01.002] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Revised: 12/23/2015] [Accepted: 01/02/2016] [Indexed: 10/22/2022]
Abstract
Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy.
Collapse
Affiliation(s)
- Monica Padilla
- House Research Institute, Department of Communication and Neuroscience, 2100 West 3rd Street, Los Angeles, CA 90057, USA; Department of Otolaryngology, New York University School of Medicine, 550 1st Avenue STE NBV 5E5, New York, NY 10016, USA; Department of Otolaryngology, Keck School of Medicine, University of Southern California, 806 W. Adams Blvd., Los Angeles, CA 90007, USA.
| | - David M Landsberger
- House Research Institute, Department of Communication and Neuroscience, 2100 West 3rd Street, Los Angeles, CA 90057, USA; Department of Otolaryngology, New York University School of Medicine, 550 1st Avenue STE NBV 5E5, New York, NY 10016, USA
| |
Collapse
|
22
|
George SS, Wise AK, Shivdasani MN, Shepherd RK, Fallon JB. Evaluation of focused multipolar stimulation for cochlear implants in acutely deafened cats. J Neural Eng 2015; 11:065003. [PMID: 25420148 DOI: 10.1088/1741-2560/11/6/065003] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The conductive nature of the fluids and tissues of the cochlea can lead to broad activation of spiral ganglion neurons using contemporary cochlear implant stimulation configurations such as monopolar (MP) stimulation. The relatively poor spatial selectivity is thought to limit implant performance, particularly in noisy environments. Several current focusing techniques have been proposed to reduce the spread of activation with the aim towards achieving improved clinical performance. APPROACH The present research evaluated the efficacy of focused multipolar (FMP) stimulation, a relatively new focusing technique in the cochlea, and compared its efficacy to both MP stimulation and tripolar (TP) stimulation. The spread of neural activity across the inferior colliculus (IC), measured by recording the spatial tuning curve, was used as a measure of spatial selectivity. Adult cats (n = 6) were acutely deafened and implanted with an intracochlear electrode array before multi-unit responses were recorded across the cochleotopic gradient of the contralateral IC. Recordings were made in response to acoustic and electrical stimulation using the MP, TP and FMP configurations. MAIN RESULTS FMP and TP stimulation resulted in greater spatial selectivity than MP stimulation. However, thresholds were significantly higher (p < 0.001) for FMP and TP stimulation compared to MP stimulation. There were no differences found in spatial selectivity and threshold between FMP and TP stimulation. SIGNIFICANCE The greater spatial selectivity of FMP and TP stimulation would be expected to result in improved clinical performance. However, further research will be required to demonstrate the efficacy of these modes of stimulation after longer durations of deafness.
Collapse
|
23
|
Fine I, Boynton GM. Pulse trains to percepts: the challenge of creating a perceptually intelligible world with sight recovery technologies. Philos Trans R Soc Lond B Biol Sci 2015; 370:20140208. [PMID: 26240423 PMCID: PMC4528820 DOI: 10.1098/rstb.2014.0208] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/13/2015] [Indexed: 11/12/2022] Open
Abstract
An extraordinary variety of sight recovery therapies are either about to begin clinical trials, have begun clinical trials, or are currently being implanted in patients. However, as yet we have little insight into the perceptual experience likely to be produced by these implants. This review focuses on methodologies, such as optogenetics, small molecule photoswitches and electrical prostheses, which use artificial stimulation of the retina to elicit percepts. For each of these technologies, the interplay between the stimulating technology and the underlying neurophysiology is likely to result in distortions of the perceptual experience. Here, we describe some of these potential distortions and discuss how they might be minimized either through changes in the encoding model or through cortical plasticity.
Collapse
Affiliation(s)
- Ione Fine
- Department of Psychology, University of Washington, Seattle, WA, USA
| | | |
Collapse
|
24
|
Tan X, Young H, Matic AI, Zirkle W, Rajguru S, Richter CP. Temporal properties of inferior colliculus neurons to photonic stimulation in the cochlea. Physiol Rep 2015; 3:3/8/e12491. [PMID: 26311831 PMCID: PMC4562577 DOI: 10.14814/phy2.12491] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Infrared neural stimulation (INS) may be beneficial in auditory prostheses because of its spatially selective activation of spiral ganglion neurons. However, the response properties of single auditory neurons to INS and the possible contributions of its optoacoustic effects are yet to be examined. In this study, the temporal properties of auditory neurons in the central nucleus of the inferior colliculus (ICC) of guinea pigs in response to INS were characterized. Spatial selectivity of INS was observed along the tonotopically organized ICC. Trains of laser pulses and trains of acoustic clicks were used to evoke single unit responses in ICC of normal hearing animals. In response to INS, ICC neurons showed lower limiting rates, longer latencies, and lower firing efficiencies. In deaf animals, ICC neurons could still be stimulated by INS while unresponsive to acoustic stimulation. The site and spatial selectivity of INS both likely shaped the temporal properties of ICC neurons.
Collapse
Affiliation(s)
- Xiaodong Tan
- Department of Otolaryngology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Hunter Young
- Department of Otolaryngology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Agnella Izzo Matic
- Department of Otolaryngology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Whitney Zirkle
- Department of Otolaryngology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Suhrud Rajguru
- Department of Biomedical Engineering, University of Miami, Miami, Florida, USA Department of Otolaryngology, University of Miami, Miami, Florida, USA
| | - Claus-Peter Richter
- Department of Otolaryngology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA The Hugh Knowles Center, Department of Communication Sciences and Disorders, Northwestern University, Evanston, Illinois, USA
| |
Collapse
|
25
|
Shannon RV. Auditory implant research at the House Ear Institute 1989-2013. Hear Res 2015; 322:57-66. [PMID: 25449009 PMCID: PMC4380593 DOI: 10.1016/j.heares.2014.11.003] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2014] [Revised: 11/04/2014] [Accepted: 11/07/2014] [Indexed: 11/29/2022]
Abstract
The House Ear Institute (HEI) had a long and distinguished history of auditory implant innovation and development. Early clinical innovations include being one of the first cochlear implant (CI) centers, being the first center to implant a child with a cochlear implant in the US, developing the auditory brainstem implant, and developing multiple surgical approaches and tools for Otology. This paper reviews the second stage of auditory implant research at House - in-depth basic research on perceptual capabilities and signal processing for both cochlear implants and auditory brainstem implants. Psychophysical studies characterized the loudness and temporal perceptual properties of electrical stimulation as a function of electrical parameters. Speech studies with the noise-band vocoder showed that only four bands of tonotopically arrayed information were sufficient for speech recognition, and that most implant users were receiving the equivalent of 8-10 bands of information. The noise-band vocoder allowed us to evaluate the effects of the manipulation of the number of bands, the alignment of the bands with the original tonotopic map, and distortions in the tonotopic mapping, including holes in the neural representation. Stimulation pulse rate was shown to have only a small effect on speech recognition. Electric fields were manipulated in position and sharpness, showing the potential benefit of improved tonotopic selectivity. Auditory training shows great promise for improving speech recognition for all patients. And the Auditory Brainstem Implant was developed and improved and its application expanded to new populations. Overall, the last 25 years of research at HEI helped increase the basic scientific understanding of electrical stimulation of hearing and contributed to the improved outcomes for patients with the CI and ABI devices. This article is part of a Special Issue entitled .
Collapse
Affiliation(s)
- Robert V Shannon
- Department of Otolaryngology, University of Southern California, Keck School of Medicine of USC, 806 W. Adams Blvd, Los Angeles, CA 90007-2505, USA.
| |
Collapse
|
26
|
Winn MB, Litovsky RY. Using speech sounds to test functional spectral resolution in listeners with cochlear implants. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 137:1430-1442. [PMID: 25786954 PMCID: PMC4368591 DOI: 10.1121/1.4908308] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2014] [Revised: 11/26/2014] [Accepted: 01/20/2015] [Indexed: 05/31/2023]
Abstract
In this study, spectral properties of speech sounds were used to test functional spectral resolution in people who use cochlear implants (CIs). Specifically, perception of the /ba/-/da/ contrast was tested using two spectral cues: Formant transitions (a fine-resolution cue) and spectral tilt (a coarse-resolution cue). Higher weighting of the formant cues was used as an index of better spectral cue perception. Participants included 19 CI listeners and 10 listeners with normal hearing (NH), for whom spectral resolution was explicitly controlled using a noise vocoder with variable carrier filter widths to simulate electrical current spread. Perceptual weighting of the two cues was modeled with mixed-effects logistic regression, and was found to systematically vary with spectral resolution. The use of formant cues was greatest for NH listeners for unprocessed speech, and declined in the two vocoded conditions. Compared to NH listeners, CI listeners relied less on formant transitions, and more on spectral tilt. Cue-weighting results showed moderately good correspondence with word recognition scores. The current approach to testing functional spectral resolution uses auditory cues that are known to be important for speech categorization, and can thus potentially serve as the basis upon which CI processing strategies and innovations are tested.
Collapse
Affiliation(s)
- Matthew B Winn
- Waisman Center and Department of Surgery, University of Wisconsin-Madison, 1500 Highland Avenue, Madison, Wisconsin 53705
| | - Ruth Y Litovsky
- Waisman Center, Department of Communication Sciences and Disorders and Department of Surgery, University of Wisconsin-Madison, 1500 Highland Avenue, Madison, Wisconsin 53705
| |
Collapse
|
27
|
Gaudrain E, Başkent D. Factors limiting vocal-tract length discrimination in cochlear implant simulations. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 137:1298-1308. [PMID: 25786943 DOI: 10.1121/1.4908235] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Perception of voice characteristics allows normal hearing listeners to identify the gender of a speaker, and to better segregate speakers from each other in cocktail party situations. This benefit is largely driven by the perception of two vocal characteristics of the speaker: The fundamental frequency (F0) and the vocal-tract length (VTL). Previous studies have suggested that cochlear implant (CI) users have difficulties in perceiving these cues. The aim of the present study was to investigate possible causes for limited sensitivity to VTL differences in CI users. Different acoustic simulations of CI stimulation were implemented to characterize the role of spectral resolution on VTL, both in terms of number of channels and amount of channel interaction. The results indicate that with 12 channels, channel interaction caused by current spread is likely to prevent CI users from perceiving VTL differences typically found between male and female speakers.
Collapse
Affiliation(s)
- Etienne Gaudrain
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
| | - Deniz Başkent
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
| |
Collapse
|
28
|
Penninger RT, Kludt E, Büchner A, Nogueira W. Stimulating on multiple electrodes can improve temporal pitch perception. Int J Audiol 2015; 54:376-83. [PMID: 25630393 DOI: 10.3109/14992027.2014.997313] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE The objective of this study was to test if stimulating multiple electrodes can improve temporal pitch ranking performance at low and high stimulation rates. DESIGN Temporal pitch cues are usually based on modifying the stimulation rate of the implant and thereby provide a continuum of pitches on a single electrode up to approximately 300 Hz. STUDY SAMPLE Ten cochlear implant subjects were asked to pitch rank stimuli presented with direct electrical stimulation. The pulses were applied on one, three, six, or eleven electrodes. In one of the conditions the current amplitude of each pulse was randomly varied between 0 and 100%. Their frequency ranged from 100 up to 500 pps. RESULTS Listeners showed the previously reported performance pattern in most conditions with very good performance at the lowest standard rates and deteriorating performance to near chance level at the highest rate tested. Performance with eleven electrodes was significantly better than performance with one electrode at 500 pps. CONCLUSION Stimulating on multiple electrodes can improve temporal pitch perception.
Collapse
|
29
|
Khalili Moghaddam G, Lovell NH, Wilke RGH, Suaning GJ, Dokos S. Performance optimization of current focusing and virtual electrode strategies in retinal implants. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2014; 117:334-342. [PMID: 25023532 DOI: 10.1016/j.cmpb.2014.06.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2013] [Revised: 06/23/2014] [Accepted: 06/23/2014] [Indexed: 06/03/2023]
Abstract
The electrode configuration in an implanted visual prosthesis array affects the spatial electric field distribution within the retina, contributing to current focusing and virtual electrode (VE) stimulation strategies. In this paper, a finite element model incorporating various electrode configurations was used to study the interaction between electrode size and electrode-to-cell distance in current focusing and VE stimulation paradigms. The electrode array unit comprises an active electrode, six flanking return electrodes and a distant monopolar return. A quasi-monopolar (QMP) fraction is defined as the proportion of current which can be preferentially returned through the distant return, in comparison with the more adjacent flanking electrodes. The simulation results indicate that current focusing and VE strategies can be optimized by tuning the QMP fraction. The QMP fraction is adjusted to optimize the electric field spread based on retinal ganglion cell (RGC) density in the degenerate retina, thereby offsetting the effect of inhomogeneous distribution of surviving RGCs and leading to a uniform stimulation paradigm across electrodes. Importantly, there is negligible difference in functional performance across electrode configurations for distances less than the electrode diameter, implying that the stimulation mode does not significantly affect activation threshold or activated retinal area for electrode diameters greater than the retinal thickness. Furthermore, the QMP fraction has a significant effect on VE performance, defined by activation threshold and activated retinal area, when threshold current is evenly divided between two adjacent active electrodes.
Collapse
Affiliation(s)
- Gita Khalili Moghaddam
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Nigel H Lovell
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Robert G H Wilke
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Gregg J Suaning
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Socrates Dokos
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia.
| |
Collapse
|
30
|
Erfanian Saeedi N, Blamey PJ, Burkitt AN, Grayden DB. Application of a pitch perception model to investigate the effect of stimulation field spread on the pitch ranking abilities of cochlear implant recipients. Hear Res 2014; 316:129-37. [DOI: 10.1016/j.heares.2014.08.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2014] [Revised: 08/14/2014] [Accepted: 08/19/2014] [Indexed: 10/24/2022]
|
31
|
Luan S, Williams I, Nikolic K, Constandinou TG. Neuromodulation: present and emerging methods. FRONTIERS IN NEUROENGINEERING 2014; 7:27. [PMID: 25076887 PMCID: PMC4097946 DOI: 10.3389/fneng.2014.00027] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2014] [Accepted: 06/24/2014] [Indexed: 12/21/2022]
Abstract
Neuromodulation has wide ranging potential applications in replacing impaired neural function (prosthetics), as a novel form of medical treatment (therapy), and as a tool for investigating neurons and neural function (research). Voltage and current controlled electrical neural stimulation (ENS) are methods that have already been widely applied in both neuroscience and clinical practice for neuroprosthetics. However, there are numerous alternative methods of stimulating or inhibiting neurons. This paper reviews the state-of-the-art in ENS as well as alternative neuromodulation techniques-presenting the operational concepts, technical implementation and limitations-in order to inform system design choices.
Collapse
Affiliation(s)
- Song Luan
- Department of Electrical and Electronic Engineering, Imperial College LondonLondon, UK
- Center for Bio-Inspired Technology, Institute of Biomedical Engineering, Imperial College LondonLondon, UK
| | - Ian Williams
- Department of Electrical and Electronic Engineering, Imperial College LondonLondon, UK
- Center for Bio-Inspired Technology, Institute of Biomedical Engineering, Imperial College LondonLondon, UK
| | - Konstantin Nikolic
- Department of Electrical and Electronic Engineering, Imperial College LondonLondon, UK
- Center for Bio-Inspired Technology, Institute of Biomedical Engineering, Imperial College LondonLondon, UK
| | - Timothy G. Constandinou
- Department of Electrical and Electronic Engineering, Imperial College LondonLondon, UK
- Center for Bio-Inspired Technology, Institute of Biomedical Engineering, Imperial College LondonLondon, UK
| |
Collapse
|
32
|
Wu CC, Luo X. Electrode spanning with partial tripolar stimulation mode in cochlear implants. J Assoc Res Otolaryngol 2014; 15:1023-36. [PMID: 24865767 DOI: 10.1007/s10162-014-0464-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2013] [Accepted: 05/07/2014] [Indexed: 11/26/2022] Open
Abstract
The perceptual effects of electrode spanning (i.e., the use of nonadjacent return electrodes) in partial tripolar (pTP) mode were tested on a main electrode EL8 in five cochlear implant (CI) users. Current focusing was controlled by σ (the ratio of current returned within the cochlea), and current steering was controlled by α (the ratio of current returned to the basal electrode). Experiment 1 tested whether asymmetric spanning with α = 0.5 can create additional channels around standard pTP stimuli. It was found that in general, apical spanning (i.e., returning current to EL6 rather than EL7) elicited a pitch between those of standard pTP stimuli on main electrodes EL8 and EL9, while basal spanning (i.e., returning current to EL10 rather than EL9) elicited a pitch between those of standard pTP stimuli on main electrodes EL7 and EL8. The pitch increase caused by apical spanning was more salient than the pitch decrease caused by basal spanning. To replace the standard pTP channel on the main electrode EL8 when EL7 or EL9 is defective, experiment 2 tested asymmetrically spanned pTP stimuli with various α, and experiment 3 tested symmetrically spanned pTP stimuli with various σ. The results showed that pitch increased with decreasing α in asymmetric spanning, or with increasing σ in symmetric spanning. Apical spanning with α around 0.69 and basal spanning with α around 0.38 may both elicit a similar pitch as the standard pTP stimulus. With the same σ, the symmetrically spanned pTP stimulus was higher in pitch than the standard pTP stimulus. A smaller σ was thus required for symmetric spanning to match the pitch of the standard pTP stimulus. In summary, electrode spanning is an effective field-shaping technique that is useful for adding spectral channels and handling defective electrodes with CIs.
Collapse
Affiliation(s)
- Ching-Chih Wu
- School of Electrical and Computer Engineering, Purdue University, 500 Oval Drive, West Lafayette, IN, 47907, USA,
| | | |
Collapse
|
33
|
Padilla M, Landsberger DM. Loudness summation using focused and unfocused electrical stimulation. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 135:EL102-EL108. [PMID: 25234912 PMCID: PMC4042455 DOI: 10.1121/1.4862877] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2013] [Accepted: 12/11/2013] [Indexed: 06/03/2023]
Abstract
With a cochlear implant, when stimulation from multiple channels is interleaved, the perceived loudness is greater than the loudness associated with any of the individual channels presented in isolation. This phenomenon is known as loudness summation. This study examined if loudness summation with monopolar and tripolar stimulation were equivalent at two loudnesses and two spacing configurations. Results suggest that loudness summation is similar for monopolar and tripolar modes. However, larger summation differences were observed for softer sounds and louder sounds with a larger spatial separation. The results are consistent with the idea that loudness summation is dependent on channel interaction and have implications for implementing current-focused processing strategies.
Collapse
Affiliation(s)
- Monica Padilla
- House Research Institute, 2100 West 3rd Street, Los Angeles, California 90057 ,
| | - David M Landsberger
- House Research Institute, 2100 West 3rd Street, Los Angeles, California 90057 ,
| |
Collapse
|
34
|
Thompson AC, Wade SA, Pawsey NC, Stoddart PR. Infrared Neural Stimulation: Influence of Stimulation Site Spacing and Repetition Rates on Heating. IEEE Trans Biomed Eng 2013; 60:3534-41. [PMID: 23864150 DOI: 10.1109/tbme.2013.2272796] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A model to simulate heating as a result of pulse repetitions during infrared neural stimulation (INS), with both single- and multiple-emitters is presented. This model allows the temperature increases from pulse trains rather than single pulses to be considered. The model predicts that using a stimulation rate of 250 Hz with typical laser parameters at a single stimulation site results in a temperature increase of 2.3°C. When multiple stimulation sites are used in analogy to cochlear implants, the temperature increases further depending upon the spacing between emitters. However, when the light is more localized at multiple stimulation sites the temperature increase is reduced.
Collapse
|
35
|
Saoji AA, Landsberger DM, Padilla M, Litvak LM. Masking patterns for monopolar and phantom electrode stimulation in cochlear implants. Hear Res 2013; 298:109-16. [PMID: 23299125 PMCID: PMC3755121 DOI: 10.1016/j.heares.2012.12.006] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2012] [Revised: 12/05/2012] [Accepted: 12/12/2012] [Indexed: 11/16/2022]
Abstract
Phantom electrode (PE) stimulation consists of out-of-phase stimulation of two electrodes. When presented at the apex of the electrode array, phantom stimulation is known to produce a lower pitch sensation than monopolar (MP) stimulation on the most apical electrode. The ratio of the current between the primary electrode (PEL) and the compensating electrode (CEL) is represented by the coefficient σ, which ranges from 0 (monopolar) to 1 (full bipolar). The exact mechanism by which PE stimulation produces a lower pitch sensation is unclear. In the present study, unmasked and masked thresholds were obtained using a forward masking paradigm to estimate the spread of current for MP and PE stimulation. Masked thresholds were measured for two phantom electrode configurations (1) PEL = 4, CEL = 5 (lower pitch phantom) and (2) PEL = 4, CEL = 3 (higher pitch phantom). The unmasked thresholds were subtracted from the masked thresholds to obtain masking patterns which were normalized to their peak. The masking patterns reveal (1) differences in the spread of excitation that are consistent with the direction of pitch shift produced by PE stimulation, and (2) narrower spread of electrical excitation for PE stimulation relative to MP stimulation.
Collapse
Affiliation(s)
- Aniket A. Saoji
- Research and Technology group, Advanced Bionics, LLC, 28515 Westinghouse Place, Valencia CA 91355, USA
| | | | - Monica Padilla
- House Research Institute, 2100 West 3rd Street, Los Angeles, CA 90057, USA
| | - Leonid M. Litvak
- Research and Technology group, Advanced Bionics, LLC, 28515 Westinghouse Place, Valencia CA 91355, USA
| |
Collapse
|
36
|
Richter CP, Rajguru S, Bendett M. Infrared neural stimulation in the cochlea. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2013; 8565:85651Y. [PMID: 25075260 DOI: 10.1117/12.2010337] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
The application of photonics to manipulate and stimulate neurons and to study neural networks has gained momentum over the last decade. Two general methods have been used: the genetic expression of light or temperature sensitive ion channels in the plasma membrane of neurons (Optogenetics and Thermogenetics) and the direct stimulation of neurons using infrared radiation (Infrared Neural Stimulation, INS). Both approaches have their strengths and challenges, which are well understood with a profound understanding of the light tissue interaction(s). This paper compares the opportunities of the methods for the use in cochlear prostheses. Ample data are already available on the stimulation of the cochlea with INS. The data show that the stimulation is selective, feasible at rates that would be sufficient to encode acoustic information and may be beneficial over conventional pulsed electrical stimulation. A third approach, using lasers in stress confinement to generate pressure waves and to stimulate the functional cochlea mechanically will also be discussed.
Collapse
Affiliation(s)
- Claus-Peter Richter
- Department of Otolaryngology, Northwestern University, 303 E. Chicago Ave, Searle 12-561, Chicago, IL 60611, USA ; Department of Biomedical Engineering, Northwestern University, 2145 Sheridan Road, Tech E310, Evanston, IL 60208, USA ; The Hugh Knowles Center, Department of Communication Sciences and Disorders, Northwestern University, Evanston, IL 60208, USA
| | - Suhrud Rajguru
- Department of Biomedical Engineering, University of Miami, Miami FL 33146, USA ; Department of Otolaryngology, University of Miami, Miami FL 33136, USA
| | - Mark Bendett
- Lockheed Martin Aculight, 22121 20th Ave SE, Bothell WA, USA
| |
Collapse
|
37
|
Srinivasan AG, Padilla M, Shannon RV, Landsberger DM. Improving speech perception in noise with current focusing in cochlear implant users. Hear Res 2013; 299:29-36. [PMID: 23467170 DOI: 10.1016/j.heares.2013.02.004] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2012] [Revised: 02/11/2013] [Accepted: 02/15/2013] [Indexed: 10/27/2022]
Abstract
Cochlear implant (CI) users typically have excellent speech recognition in quiet but struggle with understanding speech in noise. It is thought that broad current spread from stimulating electrodes causes adjacent electrodes to activate overlapping populations of neurons which results in interactions across adjacent channels. Current focusing has been studied as a way to reduce spread of excitation, and therefore, reduce channel interactions. In particular, partial tripolar stimulation has been shown to reduce spread of excitation relative to monopolar stimulation. However, the crucial question is whether this benefit translates to improvements in speech perception. In this study, we compared speech perception in noise with experimental monopolar and partial tripolar speech processing strategies. The two strategies were matched in terms of number of active electrodes, microphone, filterbanks, stimulation rate and loudness (although both strategies used a lower stimulation rate than typical clinical strategies). The results of this study showed a significant improvement in speech perception in noise with partial tripolar stimulation. All subjects benefited from the current focused speech processing strategy. There was a mean improvement in speech recognition threshold of 2.7 dB in a digits in noise task and a mean improvement of 3 dB in a sentences in noise task with partial tripolar stimulation relative to monopolar stimulation. Although the experimental monopolar strategy was worse than the clinical, presumably due to different microphones, frequency allocations and stimulation rates, the experimental partial-tripolar strategy, which had the same changes, showed no acute deficit relative to the clinical.
Collapse
Affiliation(s)
- Arthi G Srinivasan
- Department of Communication and Auditory Neuroscience, House Research Institute, 2100 West 3rd Street, Los Angeles, CA 90057, USA.
| | | | | | | |
Collapse
|
38
|
Current steering with partial tripolar stimulation mode in cochlear implants. J Assoc Res Otolaryngol 2012; 14:213-31. [PMID: 23250685 DOI: 10.1007/s10162-012-0366-8] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2012] [Accepted: 12/02/2012] [Indexed: 11/27/2022] Open
Abstract
The large spread of excitation is a major cause of poor spectral resolution for cochlear implant (CI) users. Partial tripolar (pTP) mode has been proposed to reduce current spread by returning an equally distributed fraction (0.5 × σ) of current to two flanking electrodes and the rest to an extra-cochlear ground. This study tested the efficacy of incorporating current steering into pTP mode to add spectral channels. Different proportions of current [α × σ and (1 - α) × σ] were returned to the basal and apical flanking electrodes respectively to shape the electric field. Loudness and pitch perception with α from 0 to 1 in steps of 0.1 was simulated with a computational model of CI stimulation and tested on the apical, middle, and basal electrodes of six CI subjects. The highest σ allowing for full loudness growth within the implant compliance limit was chosen for each main electrode. Pitch ranking was measured between pairs of loudness-balanced steered pTP stimuli with an α interval of 0.1 at the most comfortable level. Results demonstrated that steered pTP stimuli with α around 0.5 required more current to achieve equal loudness than those with α around 0 or 1, maybe due to more focused excitation patterns. Subjects usually perceived decreasing pitches as α increased from 0 to 1, somewhat consistent with the apical shift of the center of gravity of excitation pattern in the model. Pitch discrimination was not better with α around 0.5 than with α around 0 or 1, except for some subjects and electrodes. For three subjects with better pitch discrimination, about half of the pitch ranges of two adjacent main electrodes overlapped with each other in steered pTP mode. These results suggest that current steering with focused pTP mode may improve spectral resolution and pitch perception with CIs.
Collapse
|
39
|
Srinivasan AG, Shannon RV, Landsberger DM. Improving virtual channel discrimination in a multi-channel context. Hear Res 2012; 286:19-29. [PMID: 22616092 DOI: 10.1016/j.heares.2012.02.011] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Improving spectral resolution in cochlear implants is key to improving performance in difficult listening conditions (e.g. speech in noise, music, etc.). Current focusing might reduce channel interaction, thereby increasing spectral resolution. Previous studies have shown that combining current steering and current focusing reduces spread of excitation and improves virtual channel discrimination in a single-channel context. It is unclear whether the single-channel benefits from current focusing extend to a multi-channel context, in which the physical and perceptual interference of multiple stimulated channels might overwhelm the benefits of improved spectral resolution. In this study, signal discrimination was measured with and without current focusing, in the presence of competing stimuli on nearby electrodes. Results showed that signal discrimination was consistently better with current focusing than without, regardless of the amplitude of the competing stimuli. Therefore, combining current steering and current focusing may provide more effective spectral cues than are currently available.
Collapse
Affiliation(s)
- Arthi G Srinivasan
- Department of Communication and Auditory Neuroscience, House Research Institute, 2100 West 3rd Street, Los Angeles, CA 90057, USA.
| | | | | |
Collapse
|
40
|
Abstract
PURPOSE OF REVIEW Auditory prostheses use electric currents on multiple electrodes to stimulate auditory neurons and recreate auditory sensations in deaf people. Cochlear implants have restored hearing in more than 200 000 deaf adults and children to a level that allows most to understand speech. Here we review the reasons underlying these results and describe new directions in restoring hearing to additional patient populations and the design of new devices. RECENT FINDINGS From their early development about 50 years ago, cochlear implants have been well received and beneficial to people who had lost their hearing. Although those first implants did not allow high levels of speech understanding, they provided auditory information that worked synergistically with lip reading to improve communication. Present day cochlear implants provide excellent speech understanding in children and in postlingually deafened adults. Research is focused on improved signal processing and new electrode designs. Electric stimulation of the auditory brainstem can also produce excellent hearing in some children and adults. SUMMARY Auditory prostheses, both at the level of the sensory nerve and at the brainstem, can restore patterns of neural activation that are sufficient for high levels of speech understanding. These prostheses are not only clinically successful but also important tools for understanding sensory processing in the brain.
Collapse
|
41
|
Macherey O, Carlyon RP. Place-pitch manipulations with cochlear implants. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 131:2225-36. [PMID: 22423718 PMCID: PMC3383798 DOI: 10.1121/1.3677260] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Pitch can be conveyed to cochlear implant listeners via both place of excitation and temporal cues. The transmission of place cues may be hampered by several factors, including limitations on the insertion depth and number of implanted electrodes, and the broad current spread produced by monopolar stimulation. The following series of experiments investigate several methods to partially overcome these limitations. Experiment 1 compares two recently published techniques that aim to activate more apical fibers than produced by monopolar or bipolar stimulation of the most apical contacts. The first technique (phantom stimulation) manipulates the current spread by simultaneously stimulating two electrodes with opposite-polarity pulses of different amplitudes. The second technique manipulates the neural spread of excitation by using asymmetric pulses and exploiting the polarity-sensitive properties of auditory nerve fibers. The two techniques yielded similar results and were shown to produce lower place-pitch percepts than stimulation of monopolar and bipolar symmetric pulses. Furthermore, combining these two techniques may be advantageous in a clinical setting. Experiment 2 proposes a method to create place pitches intermediate to those produced by physical electrodes by using charge-balanced asymmetric pulses in bipolar mode with different degrees of asymmetry.
Collapse
Affiliation(s)
- Olivier Macherey
- MRC Cognition and Brain Sciences Unit, 15 Chaucer Road, Cambridge CB2 7EF, United Kingdom.
| | | |
Collapse
|
42
|
Landsberger DM, Padilla M, Srinivasan AG. Reducing current spread using current focusing in cochlear implant users. Hear Res 2012; 284:16-24. [PMID: 22230370 DOI: 10.1016/j.heares.2011.12.009] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2011] [Revised: 12/21/2011] [Accepted: 12/28/2011] [Indexed: 10/14/2022]
Abstract
Cochlear implant performance in difficult listening situations is limited by channel interactions. It is known that partial tripolar (PTP) stimulation reduces the spread of excitation (SOE). However, the greater the degree of current focusing, the greater the absolute current required to maintain a fixed loudness. As current increases, so does SOE. In experiment 1, the SOE for equally loud stimuli with different degrees of current focusing is measured via a forward-masking procedure. Results suggest that at a fixed loudness, some but not all patients have a reduced SOE with PTP stimulation. Therefore, it seems likely that a PTP speech processing strategy could improve spectral resolution for only those patients with a reduced SOE. In experiment 2, the ability to discriminate different levels of current focusing was measured. In experiment 3, patients subjectively scaled verbal descriptors of stimuli of various levels of current focusing. Both discrimination and scaling of verbal descriptors correlated well with SOE reduction, suggesting that either technique have the potential to be used clinically to quickly predict which patients would receive benefit from a current focusing strategy.
Collapse
Affiliation(s)
- David M Landsberger
- Department of Communication and Auditory Neuroscience, House Research Institute, 2100 West 3rd Street, Los Angeles, CA 90057, USA.
| | | | | |
Collapse
|
43
|
Zhu Z, Tang Q, Zeng FG, Guan T, Ye D. Cochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation. Hear Res 2012; 283:45-58. [PMID: 22138630 PMCID: PMC3277661 DOI: 10.1016/j.heares.2011.11.005] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2010] [Revised: 10/28/2011] [Accepted: 11/08/2011] [Indexed: 11/21/2022]
Abstract
Sharp spatial selectivity is critical to auditory performance, particularly in pitch-related tasks. Most contemporary cochlear implants have employed monopolar stimulation that produces broad electric fields, which presumably contribute to poor pitch and pitch-related performance by implant users. Bipolar or tripolar stimulation can generate focused electric fields but requires higher current to reach threshold and, more interestingly, has not produced any apparent improvement in cochlear-implant performance. The present study addressed this dilemma by measuring psychophysical and physiological spatial selectivity with both broad and focused stimulations in the same cohort of subjects. Different current levels were adjusted by systematically measuring loudness growth for each stimulus, each stimulation mode, and in each subject. Both psychophysical and physiological measures showed that, although focused stimulation produced significantly sharper spatial tuning than monopolar stimulation, it could shift the tuning position or even split the tuning tips. The altered tuning with focused stimulation is interpreted as a result of poor electrode-to-neuron interface in the cochlea, and is suggested to be mainly responsible for the lack of consistent improvement in implant performance. A linear model could satisfactorily quantify the psychophysical and physiological data and derive the tuning width. Significant correlation was found between the individual physiological and psychophysical tuning widths, and the correlation was improved by log-linearly transforming the physiological data to predict the psychophysical data. Because the physiological measure took only one-tenth of the time of the psychophysical measure, the present model is of high clinical significance in terms of predicting and improving cochlear-implant performance.
Collapse
Affiliation(s)
- Ziyan Zhu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
| | | | | | | | | |
Collapse
|
44
|
Landsberger D, Galvin JJ. Discrimination between sequential and simultaneous virtual channels with electrical hearing. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2011; 130:1559-1566. [PMID: 21895094 PMCID: PMC3188970 DOI: 10.1121/1.3613938] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2010] [Revised: 06/28/2011] [Accepted: 06/28/2011] [Indexed: 05/31/2023]
Abstract
In cochlear implants (CIs), simultaneous or sequential stimulation of adjacent electrodes can produce intermediate pitch percepts between those of the component electrodes. However, it is unclear whether simultaneous and sequential virtual channels (VCs) can be discriminated. In this study, CI users were asked to discriminate simultaneous and sequential VCs; discrimination was measured for monopolar (MP) and bipolar + 1 stimulation (BP + 1), i.e., relatively broad and focused stimulation modes. For sequential VCs, the interpulse interval (IPI) varied between 0.0 and 1.8 ms. All stimuli were presented at comfortably loud, loudness-balanced levels at a 250 pulse per second per electrode (ppse) stimulation rate. On average, CI subjects were able to reliably discriminate between sequential and simultaneous VCs. While there was no significant effect of IPI or stimulation mode on VC discrimination, some subjects exhibited better VC discrimination with BP + 1 stimulation. Subjects' discrimination between sequential and simultaneous VCs was correlated with electrode discrimination, suggesting that spatial selectivity may influence perception of sequential VCs. To maintain equal loudness, sequential VC amplitudes were nearly double those of simultaneous VCs, presumably resulting in a broader spread of excitation. These results suggest that perceptual differences between simultaneous and sequential VCs might be explained by differences in the spread of excitation.
Collapse
Affiliation(s)
- David Landsberger
- Division of Communication and Auditory Neuroscience, House Ear Institute, 2100 West 3rd Street, Los Angeles, California 90057, USA.
| | | |
Collapse
|
45
|
Abstract
The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies greatly in individuals and is still limited in background noise, tonal language understanding, and music perception. One main cause for the individual variability and the limited performance in cochlear implants is spatial channel interaction from the stimulating electrodes to the auditory nerve and brain. Here we systematically examined spatial channel interactions at the physical, physiological, and perceptual levels in the same five modern cochlear implant subjects. The physical interaction was examined using an electric field imaging technique, which measured the voltage distribution as a function of the electrode position in the cochlea in response to the stimulation of a single electrode. The physiological interaction was examined by recording electrically evoked compound action potentials as a function of the electrode position in response to the stimulation of the same single electrode position. The perceptual interactions were characterized by changes in detection threshold as well as loudness summation in response to in-phase or out-of-phase dual-electrode stimulation. To minimize potentially confounding effects of temporal factors on spatial channel interactions, stimulus rates were limited to 100 Hz or less in all measurements. Several quantitative channel interaction indexes were developed to define and compare the width, slope and symmetry of the spatial excitation patterns derived from these physical, physiological and perceptual measures. The electric field imaging data revealed a broad but uniformly asymmetrical intracochlear electric field pattern, with the apical side producing a wider half-width and shallower slope than the basal side. In contrast, the evoked compound action potential and perceptual channel interaction data showed much greater individual variability. It is likely that actual reduction in neural and higher level interactions, instead of simple sharpening of the electric current field, would be the key to predicting and hopefully improving the variable cochlear implant performance. The present results are obtained with auditory prostheses but can be applied to other neural prostheses, in which independent spatial channels, rather than a high stimulation rate, are critical to their performance.
Collapse
Affiliation(s)
- Qing Tang
- Departments of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences and Otolaryngology-Head and Neck Surgery, University of California, Irvine, CA, USA
| | | | | |
Collapse
|