1
|
Will M, Gerlach T, Saalfeld S, Gutberlet M, Düx D, Schröer S, Hille G, Wacker F, Hensen B, Berg P. Temperature Simulation of an Ablation Needle for the Prediction of Tissue Necrosis during Liver Ablation. J Clin Med 2024; 13:5853. [PMID: 39407914 PMCID: PMC11482482 DOI: 10.3390/jcm13195853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2024] [Revised: 08/27/2024] [Accepted: 09/26/2024] [Indexed: 10/19/2024] Open
Abstract
Background/Objectives: Microwave ablation (MWA) is the leading therapy method for treating patients with liver cancer. MWA simulation is used to further improve the therapy and to help develop new devices. Methods: A water-cooled ablation needle was reconstructed. MWA simulations of a polyacrylamide phantom were carried out and compared with a representative clinical example (tumor diameter: 8.75 mm). The Arrhenius damage model and a critical temperature approach of 60 °C were applied to assess the necrosis zones. Finally, the simulation results were compared to the corresponding MR measurements. Results: Most of the heating in the simulation took place at a distance of 5 mm along the transverse axis and 20 mm along the longitudinal axis above the needle tip. The calculated Dice scores for the Arrhenius model were 0.77/0.53 for the phantom/clinical case. For the critical temperature approach, Dice scores of 0.60/0.66 for the phantom/clinical case were achieved. Conclusions: The comparison between simulated and measured temperature increases showed an excellent agreement. However, differences in the predicted necrosis volume might be caused by omitting consideration of the heat sink effect, especially in the clinical case. Nevertheless, this workflow enables short MWA simulation times (approximately 3 min) and demonstrates a step towards possible integration into daily clinical use.
Collapse
Affiliation(s)
- Maximilian Will
- Research Campus STIMULATE, University of Magdeburg, 39106 Magdeburg, Germany; (M.W.); (T.G.); (S.S.); (M.G.); (D.D.); (S.S.); (G.H.); (F.W.); (B.H.)
| | - Thomas Gerlach
- Research Campus STIMULATE, University of Magdeburg, 39106 Magdeburg, Germany; (M.W.); (T.G.); (S.S.); (M.G.); (D.D.); (S.S.); (G.H.); (F.W.); (B.H.)
- Department Electromagnetic Compatibility, University of Magdeburg, 39106 Magdeburg, Germany
| | - Sylvia Saalfeld
- Research Campus STIMULATE, University of Magdeburg, 39106 Magdeburg, Germany; (M.W.); (T.G.); (S.S.); (M.G.); (D.D.); (S.S.); (G.H.); (F.W.); (B.H.)
- Department for Medical Informatics, University of Kiel, 24118 Kiel, Germany
| | - Marcel Gutberlet
- Research Campus STIMULATE, University of Magdeburg, 39106 Magdeburg, Germany; (M.W.); (T.G.); (S.S.); (M.G.); (D.D.); (S.S.); (G.H.); (F.W.); (B.H.)
- Institute of Diagnostic and Interventional Radiology, Hanover Medical School, 30625 Hanover, Germany
| | - Daniel Düx
- Research Campus STIMULATE, University of Magdeburg, 39106 Magdeburg, Germany; (M.W.); (T.G.); (S.S.); (M.G.); (D.D.); (S.S.); (G.H.); (F.W.); (B.H.)
- Institute of Diagnostic and Interventional Radiology, Hanover Medical School, 30625 Hanover, Germany
| | - Simon Schröer
- Research Campus STIMULATE, University of Magdeburg, 39106 Magdeburg, Germany; (M.W.); (T.G.); (S.S.); (M.G.); (D.D.); (S.S.); (G.H.); (F.W.); (B.H.)
- Institute of Diagnostic and Interventional Radiology, Hanover Medical School, 30625 Hanover, Germany
| | - Georg Hille
- Research Campus STIMULATE, University of Magdeburg, 39106 Magdeburg, Germany; (M.W.); (T.G.); (S.S.); (M.G.); (D.D.); (S.S.); (G.H.); (F.W.); (B.H.)
- Department of Simulation and Graphics, University of Magdeburg, 39106 Magdeburg, Germany
| | - Frank Wacker
- Research Campus STIMULATE, University of Magdeburg, 39106 Magdeburg, Germany; (M.W.); (T.G.); (S.S.); (M.G.); (D.D.); (S.S.); (G.H.); (F.W.); (B.H.)
- Institute of Diagnostic and Interventional Radiology, Hanover Medical School, 30625 Hanover, Germany
| | - Bennet Hensen
- Research Campus STIMULATE, University of Magdeburg, 39106 Magdeburg, Germany; (M.W.); (T.G.); (S.S.); (M.G.); (D.D.); (S.S.); (G.H.); (F.W.); (B.H.)
- Institute of Diagnostic and Interventional Radiology, Hanover Medical School, 30625 Hanover, Germany
| | - Philipp Berg
- Research Campus STIMULATE, University of Magdeburg, 39106 Magdeburg, Germany; (M.W.); (T.G.); (S.S.); (M.G.); (D.D.); (S.S.); (G.H.); (F.W.); (B.H.)
- Department of Medical Engineering, University of Magdeburg, 39106 Magdeburg, Germany
| |
Collapse
|
2
|
Keum H, Cevik E, Kim J, Demirlenk YM, Atar D, Saini G, Sheth RA, Deipolyi AR, Oklu R. Tissue Ablation: Applications and Perspectives. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2310856. [PMID: 38771628 PMCID: PMC11309902 DOI: 10.1002/adma.202310856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 05/05/2024] [Indexed: 05/22/2024]
Abstract
Tissue ablation techniques have emerged as a critical component of modern medical practice and biomedical research, offering versatile solutions for treating various diseases and disorders. Percutaneous ablation is minimally invasive and offers numerous advantages over traditional surgery, such as shorter recovery times, reduced hospital stays, and decreased healthcare costs. Intra-procedural imaging during ablation also allows precise visualization of the treated tissue while minimizing injury to the surrounding normal tissues, reducing the risk of complications. Here, the mechanisms of tissue ablation and innovative energy delivery systems are explored, highlighting recent advancements that have reshaped the landscape of clinical practice. Current clinical challenges related to tissue ablation are also discussed, underlining unmet clinical needs for more advanced material-based approaches to improve the delivery of energy and pharmacology-based therapeutics.
Collapse
Affiliation(s)
- Hyeongseop Keum
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Enes Cevik
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Jinjoo Kim
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Yusuf M Demirlenk
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Dila Atar
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Gia Saini
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Rahul A Sheth
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, Houston, Texas 77030, USA
| | - Amy R Deipolyi
- Interventional Radiology, Department of Surgery, West Virginia University, Charleston Area Medical Center, Charleston, WV 25304, USA
| | - Rahmi Oklu
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
- Division of Vascular & Interventional Radiology, Mayo Clinic, 5777 E Mayo Blvd, Phoenix, Arizona 85054, USA
| |
Collapse
|
3
|
Asafu Adjaye Frimpong G, Asante E, Mahama F, Aboagye E, Asare A. Microwave Thermal Ablation for Breast Cancer in Africa: A Pioneering Case Report Utilizing TATOpro. Cureus 2024; 16:e64029. [PMID: 38983673 PMCID: PMC11233127 DOI: 10.7759/cureus.64029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/07/2024] [Indexed: 07/11/2024] Open
Abstract
The adoption of minimally invasive treatments for early-stage breast cancer is increasing. Microwave thermal ablation (MWA), a minimally invasive technique, has been studied for treating small breast cancer lesions. However, long-term evidence on its efficacy as a sole treatment is limited, as most studies combine MWA with other therapies and post-treatment surgical excision. This report details the case of an 83-year-old African patient who declined surgery and systemic therapies, opting for MWA using the TATOpro system as the sole treatment for contralateral breast cancer with axillary lymph node metastasis. The report includes a one-year follow-up, assessing disease recurrence with MRI and ultrasound. The findings highlight MWA's potential as an innovative and efficacious breast cancer treatment, emphasizing the need for adaptable strategies in oncology.
Collapse
Affiliation(s)
- George Asafu Adjaye Frimpong
- Radiology, Kwame Nkrumah University of Science and Technology, Kumasi, GHA
- Radiology, Spectra Health Imaging and Interventional Radiology, Kumasi, GHA
| | - Emmanuel Asante
- Research and Development, Spectra Health Imaging and Interventional Radiology, Kumasi, GHA
| | - Fairuuj Mahama
- Radiology, Spectra Health Imaging and Interventional Radiology, Kumasi, GHA
| | - Evans Aboagye
- Research and Development, Spectra Health Imaging and Interventional Radiology, Kumasi, GHA
| | - Adwoa Asare
- Oncology, Komfo Anokye Teaching Hospital, Kumasi, GHA
| |
Collapse
|
4
|
Wang L, Liu BX, Long HY. Ablative strategies for recurrent hepatocellular carcinoma. World J Hepatol 2023; 15:515-524. [PMID: 37206650 PMCID: PMC10190693 DOI: 10.4254/wjh.v15.i4.515] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 02/14/2023] [Accepted: 03/29/2023] [Indexed: 04/20/2023] Open
Abstract
Hepatocellular carcinoma (HCC) is the most common primary liver cancer and is the fifth leading cause of cancer death worldwide and the third leading cause of all diseases worldwide. Liver transplantation, surgical resection and ablation are the three main curative treatments for HCC. Liver transplantation is the optimal treatment option for HCC, but its usage is limited by the shortage of liver sources. Surgical resection is considered the first choice for early-stage HCC, but it does not apply to patients with poor liver function. Therefore, more and more doctors choose ablation for HCC. However, intrahepatic recurrence occurs in up to 70% patients within 5 years after initial treatment. For patients with oligo recurrence after primary treatment, repeated resection and local ablation are both alternative. Only 20% patients with recurrent HCC (rHCC) indicate repeated surgical resection because of limitations in liver function, tumor location and intraperitoneal adhesions. Local ablation has become an option for the waiting period when liver transplantation is unavailable. For patients with intrahepatic recurrence after liver transplantation, local ablation can reduce the tumor burden and prepare them for liver transplantation. This review systematically describes the various ablation treatments for rHCC, including radiofrequency ablation, microwave ablation, laser ablation, high-intensity focused ultrasound ablation, cryablation, irreversible electroporation, percutaneous ethanol injection, and the combination of ablation and other treatment modalities.
Collapse
Affiliation(s)
- Lin Wang
- Department of Medical Ultrasound, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou 510080, Guangdong Province, China
| | - Bao-Xian Liu
- Department of Medical Ultrasound, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou 510080, Guangdong Province, China
| | - Hai-Yi Long
- Department of Medical Ultrasound, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou 510080, Guangdong Province, China
| |
Collapse
|
5
|
Afaghi P, Lapolla MA, Ghandi K. Denaturation of the SARS-CoV-2 spike protein under non-thermal microwave radiation. Sci Rep 2021; 11:23373. [PMID: 34862423 PMCID: PMC8642515 DOI: 10.1038/s41598-021-02753-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 11/18/2021] [Indexed: 01/08/2023] Open
Abstract
SARS-CoV-2, the virus that causes COVID-19, is still a widespread threat to society. The spike protein of this virus facilitates viral entry into the host cell. Here, the denaturation of the S1 subunit of this spike protein by 2.45 GHz electromagnetic radiation was studied quantitatively. The study only pertains to the pure electromagnetic effects by eliminating the bulk heating effect of the microwave radiation in an innovative setup that is capable of controlling the temperature of the sample at any desired intensity of the electromagnetic field. This study was performed at the internal human body temperature, 37 °C, for a relatively short amount of time under a high-power electromagnetic field. The results showed that irradiating the protein with a 700 W, 2.45 GHz electromagnetic field for 2 min can denature the protein to around 95%. In comparison, this is comparable to thermal denaturation at 75 °C for 40 min. Electromagnetic denaturation of the proteins of the virus may open doors to potential therapeutic or sanitation applications.
Collapse
Affiliation(s)
- Pooya Afaghi
- Department of Chemistry, University of Gulph, 50 Stone Road E, Guelph, ON, N1G 2W1, Canada
| | | | - Khashayar Ghandi
- Department of Chemistry, University of Gulph, 50 Stone Road E, Guelph, ON, N1G 2W1, Canada.
| |
Collapse
|
6
|
Li Z, Li Q, Wang X, Chen W, Jin X, Liu X, Ye F, Dai Z, Zheng X, Li P, Sun C, Liu X, Zhang Q, Luo H, Liu R. Hyperthermia ablation combined with transarterial chemoembolization versus monotherapy for hepatocellular carcinoma: A systematic review and meta-analysis. Cancer Med 2021; 10:8432-8450. [PMID: 34655179 PMCID: PMC8633247 DOI: 10.1002/cam4.4350] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Revised: 09/15/2021] [Accepted: 10/03/2021] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND AND AIMS The existing evidence has indicated that hyperthermia ablation (HA) and HA combined with transarterial chemoembolization (HATACE) are the optimal alternative to surgical resection for patients with hepatocellular carcinoma (HCC) in the COVID-19 crisis. However, the evidence for decision-making is lacking in terms of comparison between HA and HATACE. Herein, a comprehensive evaluation was performed to compare the efficacy and safety of HATACE with monotherapy. MATERIALS AND METHODS Worldwide studies were collected to evaluate the HATACE regimen for HCC due to the practical need for global extrapolation of applicative population. Meta-analyses were performed using the RevMan 5.3 software (The Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark). RESULTS Thirty-six studies involving a large sample of 5036 patients were included finally. Compared with HA alone, HATACE produced the advantage of 5-year overall survival (OS) rate (OR:1.90; 95%CI:1.46,2.46; p < 0.05) without increasing toxicity (p ≥ 0.05). Compared with TACE alone, HATACE was associated with superior 5-year OS rate (OR:3.54; 95%CI:1.96,6.37; p < 0.05) and significantly reduced the incidences of severe liver damage (OR:0.32; 95%CI:0.11,0.96; p < 0.05) and ascites (OR:0.42; 95%CI:0.20,0.88; p < 0.05). Subgroup analysis results of small (≤3 cm) HCC revealed that there were no significant differences between the HATACE group and HA monotherapy group in regard to the OS rates (p ≥ 0.05). CONCLUSIONS Compared with TACE alone, HATACE was more effective and safe for HCC. Compared with HA alone, HATACE was more effective for non-small-sized (>3 cm) HCC with comparable safety. However, the survival benefit of adjuvant TACE in HATACE regimen was not found for the patients with small (≤3 cm) HCC.
Collapse
|
7
|
On Efficacy of Microwave Ablation in the Thermal Treatment of an Early-Stage Hepatocellular Carcinoma. Cancers (Basel) 2021; 13:cancers13225784. [PMID: 34830937 PMCID: PMC8616542 DOI: 10.3390/cancers13225784] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 11/08/2021] [Accepted: 11/16/2021] [Indexed: 02/08/2023] Open
Abstract
Microwave ablation at 2.45 GHz is gaining popularity as an alternative therapy to hepatic resection with a higher overall survival rate than external beam radiation therapy and proton beam therapy. It also offers better long-term recurrence-free overall survival when compared with radiofrequency ablation. To improve the design and optimization of microwave ablation procedures, numerical models can provide crucial information. A three-dimensional model of the antenna and targeted tissue without homogeneity assumptions are the most realistic representation of the physical problem. Due to complexity and computational resources consumption, most of the existing numerical studies are based on using two-dimensional axisymmetric models to emulate actual three-dimensional cancers and surrounding tissue, which is often far from reality. The main goal of this study is to develop a fully three-dimensional model of a multislot microwave antenna immersed into liver tissue affected by early-stage hepatocellular carcinoma. The geometry of the tumor is taken from the 3D-IRCADb-01 liver tumors database. Simulations were performed involving the temperature dependence of the blood perfusion, dielectric and thermal properties of both healthy and tumoral liver tissues. The water content changes during the ablation process are also included. The optimal values of the input power and the ablation time are determined to ensure complete treatment of the tumor with minimal damage to the healthy tissue. It was found that a multislot antenna is designed to create predictable, large, spherical zones of the ablation that are not influenced by varying tissue environments. The obtained results may be useful for determining optimal conditions necessary for microwave ablation to be as effective as possible for treating early-stage hepatocellular carcinoma, with minimized invasiveness and collateral damages.
Collapse
|