1
|
Novi VT, Meher AK, Abbas A. Visualization methods for loop mediated isothermal amplification (LAMP) assays. Analyst 2025; 150:588-599. [PMID: 39895350 DOI: 10.1039/d4an01287a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2025]
Abstract
Recent advances in nucleic acid (NA) detection techniques have significantly enhanced the diagnosis of diseases caused by a range of pathogens. These NA-based methods that target specific gene sequences for identification offer high specificity. Despite the effectiveness of polymerase chain reaction (PCR), its requirement for sophisticated laboratory settings and expensive equipment restricts its accessibility, particularly in resource-limited settings. As an alternative, isothermal nucleic acid amplification methods are highly sought after due to their rapid, sensitive, and specific detection ability. Among these, loop mediated isothermal amplification (LAMP) stands out due to its simplicity, reliability, and cost-effectiveness. LAMP operates without the need for varied temperature cycles, employing a simple heating block to maintain a constant temperature, thus facilitating onsite rapid testing. In LAMP, the detection step is critical as it shows the outcome of the assay. In order to make the LAMP technique user-friendly and applicable for large scale testing, it is critical to have visual detection where the results can be observed with the naked eye. This review focuses on recent developments of LAMP visualization techniques, including the more common fluorescence, turbidity, and gel electrophoresis methods, as well as innovations in colorimetric techniques applying novel transduction methods such as nanoparticles and digital tools. Additionally, various practical applications of LAMP are discussed.
Collapse
Affiliation(s)
- Vinni Thekkudan Novi
- Department of Bioproducts and Biosystems Engineering, University of Minnesota, St Paul, MN 55108, USA..
| | - Anil Kumar Meher
- Department of Bioproducts and Biosystems Engineering, University of Minnesota, St Paul, MN 55108, USA..
| | - Abdennour Abbas
- Department of Bioproducts and Biosystems Engineering, University of Minnesota, St Paul, MN 55108, USA..
| |
Collapse
|
2
|
Mirlohi MS, Pishbin E, Dezhkam R, Kiani MJ, Shamloo A, Salami S. Innovative PNA-LB mediated allele-specific LAMP for KRAS mutation profiling on a compact lab-on-a-disc device. Talanta 2024; 276:126224. [PMID: 38772176 DOI: 10.1016/j.talanta.2024.126224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Revised: 04/24/2024] [Accepted: 05/05/2024] [Indexed: 05/23/2024]
Abstract
Tailored healthcare, an approach focused on individual patients, requires integrating emerging interdisciplinary technologies to develop accurate and user-friendly diagnostic tools. KRAS mutations, prevalent in various common cancers, are crucial determinants in selecting patients for novel KRAS inhibitor therapies. This study presents a novel state-of-the-art Lab-on-a-Disc system utilizing peptide nucleic acids-loop backward (PNA-LB) mediated allele-specific loop-mediated isothermal amplification (LAMP) for detecting the frequent G12D KRAS mutation, signifying its superiority over alternative mutation detection approaches. The designed Lab-on-a-Disc system demonstrated exceptional preclinical and technical precision, accuracy, and versatility. By applying varying cutoff values to PNA- LB LAMP reactions, the assay's sensitivity and specificity were increased by 80 % and 90 %, respectively. The device's key advantages include a robust microfluidic Lab-on-a-Disc design, precise rotary control, and a cutting-edge induction heating module. These features enable multiplexing of LAMP reactions with high reproducibility and repeatability, with CV% values less than 3.5 % and 5.5 %, respectively. The device offers several methods for accurate endpoint result detection, including naked-eye observation, RGB image analysis using Python code, and time of fluorescence (Tf) values. Preclinical specificity and sensitivity, assessed using different cutoffs for Eva-Green fluorescence Tf values and pH-sensitive dyes, demonstrated comparable performance to the best standard methods. Overall, this study represents a significant step towards tailoring treatment strategies for cancer patients through precise and efficient mutation detection technologies.
Collapse
Affiliation(s)
- Maryam Sadat Mirlohi
- Clinical Biochemistry Department, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Esmail Pishbin
- Bio-microfluidics Laboratory, Department of Electrical Engineering and Information Technology, Iranian Research Organization for Science and Technology, Tehran, Iran.
| | - Rasool Dezhkam
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran; Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Mohammad Javad Kiani
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Amir Shamloo
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - Siamak Salami
- Clinical Biochemistry Department, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
3
|
Nawab M, Riaz SK, Ismail E, Ahamed A, Tariq A, Malik MFA, Qusty NF, Bantun F, Slama P, Umair M, Haque S, Bonilla-Aldana DK, Rodriguez-Morales AJ. Integrated approach for detection of SARS-CoV-2 and its variant by utilizing LAMP and ARMS-PCR. Ann Clin Microbiol Antimicrob 2024; 23:11. [PMID: 38303011 PMCID: PMC10836012 DOI: 10.1186/s12941-023-00665-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 12/26/2023] [Indexed: 02/03/2024] Open
Abstract
Global impact of COVID-19 pandemic has heightened the urgency for efficient virus detection and identification of variants such as the Q57H mutation. Early and efficient detection of SARS-CoV-2 among densely populated developing countries is paramount objective. Although RT-PCR assays offer accuracy, however, dependence on expansive kits and availability of allied health resources pose an immense challenge for developing countries. In the current study, RT-LAMP based detection of SARS-Cov-2 with subsequent confirmation of Q57H variant through ARMS-PCR was performed. Among the 212 collected samples, 134 yielded positive results, while 78 tested negative using RT-LAMP. Oropharyngeal swabs of suspected individuals were collected and processed for viral RNA isolation. Isolated viral RNA was processed further by using either commercially available WarmStart Master Mix or our in house developed LAMP master mix separately. Subsequently, the end results of each specimen were evaluated by colorimetry. For LAMP assays, primers targeting three genes (ORF1ab, N and S) were designed using PrimerExplorer software. Interestingly, pooling of these three genes in single reaction tube increased sensitivity (95.5%) and specificity (93.5%) of LAMP assay. SARS-CoV-2 positive specimens were screened further for Q57H mutation using ARMS-PCR. Based on amplicon size variation, later confirmed by sequencing, our data showed 18.5% samples positive for Q57H mutation. Hence, these findings strongly advocate use of RT-LAMP-based assay for SARS-CoV-2 screening within suspected general population. Furthermore, ARMS-PCR also provides an efficient mean to detect prevalent mutations against SARS-Cov-2.
Collapse
Affiliation(s)
- Maryam Nawab
- Department of Biosciences, COMSATS University Islamabad, Islamabad, Pakistan
| | - Syeda Kiran Riaz
- Department of Biosciences, COMSATS University Islamabad, Islamabad, Pakistan
- Department of Molecular Biology, Shaheed Zulfiqar Ali Bhutto Medical University, Islamabad, Pakistan
| | - Eiman Ismail
- Department of Biosciences, COMSATS University Islamabad, Islamabad, Pakistan
| | - Alfar Ahamed
- Department of Biosciences, COMSATS University Islamabad, Islamabad, Pakistan
| | - Aaysha Tariq
- Molecular Diagnostic Unit, Clinical Pathology Department, PAEC General Hospital, Islamabad, Pakistan
| | | | - Naeem F Qusty
- Laboratory Medicine Department, Faculty of Applied Medical Sciences, Umm Al-Qura University, PO Box 7607, Makkah, Al Abdeyah, Saudi Arabia
| | - Farkad Bantun
- Department of Microbiology, Faculty of Medicine, Umm Al-Qura University, Makkah, Saudi Arabia
| | - Petr Slama
- Laboratory of Animal Immunology and Biotechnology, Department of Animal Morphology, Physiology and Genetics, Faculty of AgriSciences, Mendel University in Brno, Brno, 61300, Czech Republic
| | - Massab Umair
- Department of Virology, National Institute of Health (NIH), Islamabad, Pakistan
| | - Shafiul Haque
- Research and Scientific Studies Unit, College of Nursing and Health Sciences, Jazan University, Jazan, 45142, Saudi Arabia
- Gilbert and Rose-Marie Chagoury School of Medicine, Lebanese American University, Beirut, 1102 2801, Lebanon
- Centre of Medical and Bio-Allied Health Sciences Research, Ajman University, Ajman, 13306, United Arab Emirates
| | | | - Alfonso J Rodriguez-Morales
- Gilbert and Rose-Marie Chagoury School of Medicine, Lebanese American University, Beirut, 1102 2801, Lebanon
- Master Program on Clinical Epidemiology and Biostatistics, Faculty of Health Sciences, Universidad Científica del Sur, Lima, 15046, Peru
| |
Collapse
|
4
|
Kim EYS, Imamura LM, Winkert Raddatz B, Timm Soares SP, Alves Ribeiro VH, Rinaldi Pavesi Nicollete D, Bergamo Santiago E, Mazega Figueredo MV, Montesanti Machado de Almeida B, Renato Rogal S. Data treatment methods for real-time colorimetric loop-mediated isothermal amplification reactions. Sci Rep 2023; 13:14397. [PMID: 37658115 PMCID: PMC10474118 DOI: 10.1038/s41598-023-40737-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 08/16/2023] [Indexed: 09/03/2023] Open
Abstract
With the SARS-CoV-2 pandemic and the need for affordable and rapid mass testing, colorimetric isothermal amplification reactions such as Loop-Mediated Isothermal Amplification (LAMP) are quickly rising in importance. The technique generates data that is similar to quantitative Polymerase Chain Reaction (qPCR), but instead of an endpoint color visualization, it is possible to construct a signal over a time curve. As the number of works using time-course analysis of isothermal reactions increases, there is a need to analyze data and standardize their related treatments quantitatively. Here, we take a step forward toward this goal by evaluating different available data treatments (curve models) for amplification curves, which allows for a cycle threshold-like parameter extraction. In this study, we uncover evidence of a double sigmoid equation as the most adequate model to describe amplification data from our remote diagnostics system and discuss possibilities for similar setups. We also demonstrate the use of multimodal Gompertz regression models. Thus, this work provides advances toward standardized and unbiased data reporting of Reverse Transcription (RT) LAMP reactions, which may facilitate and quicken assay interpretation, potentially enabling the application of machine learning techniques for further optimization and classification.
Collapse
Affiliation(s)
- Edson Yu Sin Kim
- Hilab, Rua José Altair Possebom, 800-CIC, Curitiba, Paraná, 81270-185, Brazil
| | | | | | | | | | | | | | | | | | - Sergio Renato Rogal
- Hilab, Rua José Altair Possebom, 800-CIC, Curitiba, Paraná, 81270-185, Brazil
| |
Collapse
|
5
|
Cai D, Wang Y, Zou J, Li Z, Huang E, Ouyang X, Que Z, Luo Y, Chen Z, Jiang Y, Zhang G, Wu H, Liu D. Droplet Encoding-Pairing Enabled Multiplexed Digital Loop-Mediated Isothermal Amplification for Simultaneous Quantitative Detection of Multiple Pathogens. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2205863. [PMID: 36646503 PMCID: PMC9982564 DOI: 10.1002/advs.202205863] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Revised: 12/06/2022] [Indexed: 06/01/2023]
Abstract
Despite the advantages of digital nucleic acid analysis (DNAA) in terms of sensitivity, precision, and resolution, current DNAA methods commonly suffer a limitation in multiplexing capacity. To address this issue, a droplet encoding-pairing enabled DNAA multiplexing strategy is developed, wherein unique tricolor combinations are deployed to index individual primer droplets. The template droplets and primer droplets are sequentially introduced into a microfluidic chip with a calabash-shaped microwell array and are pairwise trapped and merged in the microwells. Pre-merging and post-amplification image analysis with a machine learning algorithm is used to identify, enumerate, and address the droplets. By incorporating the amplification signals with droplet encoding information, simultaneous quantitative detection of multiple targets is achieved. This strategy allows for the establishment of flexible multiplexed DNAA by simply adjusting the primer droplet library. Its flexibility is demonstrated by establishing two multiplexed (8-plex) droplet digital loop-mediated isothermal amplification (mddLAMP) assays for individually detecting lower respiratory tract infection and urinary tract infection causative pathogens. Clinical sample analysis shows that the microbial detection outcomes of the mddLAMP assays are consistent with those of the conventional assay. This DNAA multiplexing strategy can achieve flexible high-order multiplexing on demand, making it a desirable tool for high-content pathogen detection.
Collapse
Affiliation(s)
- Dongyang Cai
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Yu Wang
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Jingjing Zou
- College of Food Science and EngineeringSouth China University of TechnologyGuangzhou510640China
| | - Zhujun Li
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Enqi Huang
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Xiuyun Ouyang
- College of Food Science and EngineeringSouth China University of TechnologyGuangzhou510640China
| | - Zhiquan Que
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Yanzhang Luo
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Zhenhua Chen
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Yanqing Jiang
- Beijing Baicare Biotechnology Co., LtdBeijing102206China
| | - Guohao Zhang
- Beijing Baicare Biotechnology Co., LtdBeijing102206China
| | - Hongkai Wu
- Department of ChemistryHong Kong University of Science and TechnologyHong KongChina
| | - Dayu Liu
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
- Guangdong Engineering Technology Research Center of Microfluidic Chip Medical DiagnosisGuangzhou510180China
- Clinical Molecular Medicine and Molecular Diagnosis Key Laboratory of Guangdong ProvinceGuangzhou510180China
| |
Collapse
|
6
|
Abstract
INTRODUCTION The SARS-CoV-2 pandemic, and the subsequent limitations on standard diagnostics, has vastly expanded the user base of Reverse Transcription Loop-mediated isothermal Amplification (RT-LAMP) in fundamental research and development. RT-LAMP has also penetrated commercial markets, with emergency use authorizations for clinical diagnosis. AREAS COVERED This review discusses the role of RT-LAMP within the context of other technologies like RT-qPCR and rapid antigen tests, progress in sample preparation strategies to enable simplified workflow for RT-LAMP directly from clinical specimens, new challenges with primer and assay design for the evolving pandemic, prominent detection modalities including colorimetric and CRISPR-mediated methods, and translational research and commercial development of RT-LAMP for clinical applications. EXPERT OPINION RT-LAMP occupies a middle ground between RT-qPCR and rapid antigen tests. The simplicity approaches that of rapid antigen tests, making it suitable for point-of-care use, but the sensitivity nears that of RT-qPCR. RT-LAMP still lags RT-qPCR in fundamental understanding of the mechanism, and the interplay between sample preparation and assay performance. Industry is now beginning to address issues around scalability and usability, which could finally enable LAMP and RT-LAMP to find future widespread application as a diagnostic for other conditions, including other pathogens with pandemic potential.
Collapse
Affiliation(s)
- Gihoon Choi
- Biotechnology & Bioengineering Department, Sandia National Laboratories, Livermore, CA, USA
| | - Taylor J Moehling
- Biotechnology & Bioengineering Department, Sandia National Laboratories, Livermore, CA, USA
| | - Robert J Meagher
- Biotechnology & Bioengineering Department, Sandia National Laboratories, Livermore, CA, USA
| |
Collapse
|
7
|
Development of an optimized colorimetric RT-LAMP for SARS-CoV-2 assay with enhanced procedure controls for remote diagnostics. Sci Rep 2022; 12:21424. [PMID: 36503901 PMCID: PMC9741705 DOI: 10.1038/s41598-022-25872-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 12/06/2022] [Indexed: 12/14/2022] Open
Abstract
The coronavirus pandemic accentuated the need for molecular diagnostic tests. A technique highly used to this end is the Polymerase Chain Reaction (PCR)-a sensitive and specific technique commonly used as the gold standard for molecular diagnostics. However, it demands highly trained personnel and high-maintenance equipment and is relatively time-consuming. An alternative is the Loop-Mediated Isothermal Amplification (LAMP) technique, which doesn't need sample purification or expensive equipment, and is similar to PCR when compared in sensitivity and specificity. In this paper, we developed an optimized colorimetric Reverse Transcriptase Loop-Mediated Isothermal Amplification (RT-LAMP) Point-of-Care test using a portable device to diagnose COVID-19. Variables such as concentration of primers, magnesium sulfate, betaine, hydrochloride guanidine, Bst, and temperature of the reactions were tested. We also created a pipetting quality control system-using a combination of dyes-to avoid false negatives due to a lack of samples added to the reaction test tube. Mineral oil was incorporated in the composition of the RT-LAMP reactions to avoid evaporation when a heating lid isn't available. The final RT-LAMP test is tenfold more sensitive when compared to the WarmStart Colorimetric Master mix from New England Biolabs with a sensitivity of 5 copies per μL.
Collapse
|
8
|
Ganesh PS, Kim SY. A comparison of conventional and advanced electroanalytical methods to detect SARS-CoV-2 virus: A concise review. CHEMOSPHERE 2022; 307:135645. [PMID: 35817176 PMCID: PMC9270057 DOI: 10.1016/j.chemosphere.2022.135645] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 07/04/2022] [Accepted: 07/05/2022] [Indexed: 06/15/2023]
Abstract
Respiratory viruses are a serious threat to human wellbeing that can cause pandemic disease. As a result, it is critical to identify virus in a timely, sensitive, and precise manner. The present novel coronavirus-2019 (COVID-19) disease outbreak has increased these concerns. The research of developing various methods for COVID-19 virus identification is one of the most rapidly growing research areas. This review article compares and addresses recent improvements in conventional and advanced electroanalytical approaches for detecting COVID-19 virus. The popular conventional methods such as polymerase chain reaction (PCR), loop mediated isothermal amplification (LAMP), serology test, and computed tomography (CT) scan with artificial intelligence require specialized equipment, hours of processing, and specially trained staff. Many researchers, on the other hand, focused on the invention and expansion of electrochemical and/or bio sensors to detect SARS-CoV-2, demonstrating that they could show a significant role in COVID-19 disease control. We attempted to meticulously summarize recent advancements, compare conventional and electroanalytical approaches, and ultimately discuss future prospective in the field. We hope that this review will be helpful to researchers who are interested in this interdisciplinary field and desire to develop more innovative virus detection methods.
Collapse
Affiliation(s)
- Pattan-Siddappa Ganesh
- Interaction Laboratory, Advanced Technology Research Center, Future Convergence Engineering, Korea University of Technology and Education (KoreaTech), Cheonan-si, Chungcheongnam-do, 330-708, Republic of Korea.
| | - Sang-Youn Kim
- Interaction Laboratory, Advanced Technology Research Center, Future Convergence Engineering, Korea University of Technology and Education (KoreaTech), Cheonan-si, Chungcheongnam-do, 330-708, Republic of Korea.
| |
Collapse
|
9
|
Lai MY, Bukhari FDM, Zulkefli NZ, Ismail I, Mustapa NI, Soh TST, Hassan AH, Peariasamy KM, Lee YL, Suppiah J, Thayan R, Isa MKM, Wahid NZA, Lau YL. Clinical testing on SARS-CoV-2 swab samples using reverse-transcription loop-mediated isothermal amplification (RT-LAMP). BMC Infect Dis 2022; 22:697. [PMID: 35982419 PMCID: PMC9387413 DOI: 10.1186/s12879-022-07684-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 07/28/2022] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND High cost of commercial RNA extraction kits limits the testing efficiency of SARS-CoV-2. Here, we developed a simple nucleic acid extraction method for the detection of SARS-CoV-2 directly from nasopharyngeal swab samples. METHODS A pH sensitive dye was used as the end point detection method. The obvious colour changes between positive and negative reactions eliminates the need of other equipment. RESULTS Clinical testing using 260 samples showed 92.7% sensitivity (95% CI 87.3-96.3%) and 93.6% specificity (95% CI 87.3-97.4%) of RT-LAMP. CONCLUSIONS The simple RNA extraction method minimizes the need for any extensive laboratory set-up. We suggest combining this simple nucleic acid extraction method and RT-LAMP technology as the point-of care diagnostic tool.
Collapse
Affiliation(s)
- Meng Yee Lai
- Department of Parasitology, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | | | - Nur Zulaikha Zulkefli
- Department of Parasitology, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Ilyiana Ismail
- Department of Pathology, Hospital Sungai Buloh, Ministry of Health, Kuala Lumpur, Malaysia
| | - Nur Izati Mustapa
- Department of Pathology, Hospital Sungai Buloh, Ministry of Health, Kuala Lumpur, Malaysia
| | - Tuan Suhaila Tuan Soh
- Department of Pathology, Hospital Sungai Buloh, Ministry of Health, Kuala Lumpur, Malaysia
| | - Afifah Haji Hassan
- Department of Pathology, Hospital Sungai Buloh, Ministry of Health, Kuala Lumpur, Malaysia
| | - Kalaiarasu M Peariasamy
- Institute for Clinical Research, National Institutes of Health, Ministry of Health, Kuala Lumpur, Malaysia
| | - Yee Leng Lee
- Clinical Research Centre, Hospital Sungai Buloh, Ministry of Health, Kuala Lumpur, Malaysia
| | - Jeyanthi Suppiah
- Virology Unit, Infectious Disease Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health, Kuala Lumpur, Malaysia
| | - Ravindran Thayan
- Virology Unit, Infectious Disease Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health, Kuala Lumpur, Malaysia
| | - Mohd Khairi Mat Isa
- Selia-Tek Holdings Sdn Bhd, Lot 18, Jalan Teknologi 3/5, Taman Sains Selangor, 47810, Kota Damansara, Selangor, Malaysia
| | - Nur Zafirah Abdul Wahid
- Selia-Tek Holdings Sdn Bhd, Lot 18, Jalan Teknologi 3/5, Taman Sains Selangor, 47810, Kota Damansara, Selangor, Malaysia
| | - Yee Ling Lau
- Department of Parasitology, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia.
| |
Collapse
|
10
|
Asghar R, Rasheed M, ul Hassan J, Rafique M, Khan M, Deng Y. Advancements in Testing Strategies for COVID-19. BIOSENSORS 2022; 12:410. [PMID: 35735558 PMCID: PMC9220779 DOI: 10.3390/bios12060410] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2022] [Revised: 06/06/2022] [Accepted: 06/07/2022] [Indexed: 12/15/2022]
Abstract
The SARS-CoV-2 coronavirus, also known as the disease-causing agent for COVID-19, is a virulent pathogen that may infect people and certain animals. The global spread of COVID-19 and its emerging variation necessitates the development of rapid, reliable, simple, and low-cost diagnostic tools. Many methodologies and devices have been developed for the highly sensitive, selective, cost-effective, and rapid diagnosis of COVID-19. This review organizes the diagnosis platforms into four groups: imaging, molecular-based detection, serological testing, and biosensors. Each platform's principle, advancement, utilization, and challenges for monitoring SARS-CoV-2 are discussed in detail. In addition, an overview of the impact of variants on detection, commercially available kits, and readout signal analysis has been presented. This review will expand our understanding of developing advanced diagnostic approaches to evolve into susceptible, precise, and reproducible technologies to combat any future outbreak.
Collapse
Affiliation(s)
- Rabia Asghar
- Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, School of Life Sciences, Beijing Institute of Technology, Beijing 100081, China;
| | - Madiha Rasheed
- Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, School of Life Sciences, Beijing Institute of Technology, Beijing 100081, China;
| | - Jalees ul Hassan
- Department of Wildlife and Ecology, Faculty of Fisheries and Wildlife, University of Veterinary and Animal Sciences-UVAS, Lahore 54000, Pakistan;
| | - Mohsin Rafique
- Beijing Academy of Quantum Information Sciences, Beijing 100193, China;
| | - Mashooq Khan
- Shandong Analysis and Test Center, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China;
| | - Yulin Deng
- Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, School of Life Sciences, Beijing Institute of Technology, Beijing 100081, China;
| |
Collapse
|
11
|
Garrido-Maestu A, Prado M. Naked-eye detection strategies coupled with isothermal nucleic acid amplification techniques for the detection of human pathogens. Compr Rev Food Sci Food Saf 2022; 21:1913-1939. [PMID: 35122372 DOI: 10.1111/1541-4337.12902] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 12/13/2021] [Accepted: 12/14/2021] [Indexed: 12/26/2022]
Abstract
Nucleic acid amplification-based techniques have gained acceptance by the scientific, and general, community as reference methodologies for many different applications. Since the development of the gold standard of these techniques, polymerase chain reaction (PCR), back in the 1980s many improvements have been made, and alternative techniques emerged reporting improvements over PCR. Among these, isothermal amplification approaches resulted of particular interest as could overcome the need of specialized equipment to accurately control temperature changes, but it was after year 2000 that these techniques have flourished in a huge number of novel alternatives with many different degrees of complexities and requirements. An added value is their possibility to be combined with many different naked-eye detection strategies, simplifying the resources needed, allowing to reduce cost, and serving as the basis for novel developments of lab-on-chip systems, and miniaturized devices, for point-of-care testing. In this review, we will go over different types of naked-eye detection strategies, combined with isothermal amplification. This will provide the readers up-to-date information for them to select the most appropriate strategies depending on the particular needs and resources for their experimental setup.
Collapse
Affiliation(s)
- Alejandro Garrido-Maestu
- Food Quality and Safety Research Group, International Iberian Nanotechnology Laboratory, Braga, Portugal
| | - Marta Prado
- Food Quality and Safety Research Group, International Iberian Nanotechnology Laboratory, Braga, Portugal
| |
Collapse
|
12
|
Artik Y, Coşğun AB, Cesur NP, Hızel N, Uyar Y, Sur H, Ayan A. Comparison of COVID-19 laboratory diagnosis by commercial kits: Effectivity of RT-PCR to the RT-LAMP. J Med Virol 2022; 94:1998-2007. [PMID: 34997587 PMCID: PMC9015626 DOI: 10.1002/jmv.27559] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Accepted: 12/27/2021] [Indexed: 01/08/2023]
Abstract
Coronavirus disease 2019 or COVID-19 caused by novel coronavirus/severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2 or 2019-nCoV) is an ongoing pandemic that has emerging global effects and requires rapid and reliable diagnostic testing. Quantitative reverse transcription-polymerase chain reaction (q-RT-PCR) is the gold standard method for SARS-CoV-2 detections. On the other hand, new approaches remedy the diagnosis difficulties gradually. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) as one of these novel approaches may also contribute to faster and cheaper field-based testing. The present study was designed to evaluate this rapid screening diagnostic test that can give results in 30-45 min and to compare the effectiveness of LAMP to the q-RT-PCR. The 30 randomly chosen patient samples were generated by nasopharyngeal swabs with a portion of the SARS-CoV-2 nucleic sequence. The sample of quantification cycle (Cq) values was tested using RT-LAMP as well as by conventional q-RT-PCR. The patient samples were tested with four different kits (SENSObiz COVID-19 [SARS-CoV-2] LAMP Assay, the QIAseq DIRECT SARS-CoV-2 kit, Biospeedy SARS-CoV-2 Variant Plus kit, and CoVirion-CV19-2 SARS-CoV-2 OneStep RT-PCR kit) and two different PCR devices (GDS Rotor-Gene Q Thermocycler and Inovia Technologies GenX series). Based on 30 patient samples, the positive/negative ratio (P/N) was 30/0 as Biospeedy and Covirion (positivity 100%), 28/2 as Qiagen kit (positivity 93.3%) for the samples studied on the Inovia device while the same samples on the Rotor-Gene device were 30/0 as Biospeedy and Covirion (positivity 100%), 29/1 as Qiagen kit at the first day (96.7%). On the fifth day, the samples were studied in the Inovia device and the respective results were obtained: 27/3 as Biospeedy (positivity 90%), 16/14 as Qiagen (positivity 53.3%), 28/2 as Covirion kit (positivity 93.3%). When these samples were studied in the Rotor-Gene device, it was 29/1 in Biospeedy and Covirion (positivity 96.7%), 19/11 in the Qiagen kit (positivity 63.3%). When these samples were compared with the LAMP method it was found to be 19/11 (positivity 63.3%) on the first day and 18/12 (positivity 60%) on the fifth day. SARS-CoV-2 test studies will contribute to a proactive approach to the development of rapid diagnosis systems. The LAMP approach presents promising results to monitor exposed individuals and also improves screening efforts in potential ports of entry.
Collapse
Affiliation(s)
- Yakup Artik
- Republic of Turkey, Ministry of Health, Health Institutes of Turkey (TUSEB), COVID-19 Diagnostic Center, University of Health Sciences, Kanuni Sultan Süleyman Training and Research Hospital, Istanbul, Küçükçekmece, Turkey.,Private Viromed Istanbul Central Laboratory and Imaging Center, COVID-19 Diagnostic Center, Istanbul, Şişli, Turkey.,Department of Molecular Biology and Genetics, Istanbul Kültür University, Faculty of Science and Letters, Istanbul, Bakırköy, Turkey
| | - Alp B Coşğun
- Private Viromed Istanbul Central Laboratory and Imaging Center, COVID-19 Diagnostic Center, Istanbul, Şişli, Turkey
| | - Nevra P Cesur
- Republic of Turkey, Ministry of Health, Health Institutes of Turkey (TUSEB), COVID-19 Diagnostic Center, University of Health Sciences, Kanuni Sultan Süleyman Training and Research Hospital, Istanbul, Küçükçekmece, Turkey.,Private Viromed Istanbul Central Laboratory and Imaging Center, COVID-19 Diagnostic Center, Istanbul, Şişli, Turkey
| | - Nedret Hızel
- Private Viromed Istanbul Central Laboratory and Imaging Center, COVID-19 Diagnostic Center, Istanbul, Şişli, Turkey.,Faculty of Medicine, Medical Biochemistry, Üsküdar University, Istanbul, Üsküdar, Turkey
| | - Yavuz Uyar
- Private Viromed Istanbul Central Laboratory and Imaging Center, COVID-19 Diagnostic Center, Istanbul, Şişli, Turkey
| | - Haydar Sur
- Department of Public Health, Faculty of Medicine, Üsküdar University, Istanbul, Üsküdar, Turkey
| | - Alp Ayan
- Department of Molecular Biology and Genetics, Istanbul Kültür University, Faculty of Science and Letters, Istanbul, Bakırköy, Turkey
| |
Collapse
|
13
|
Padzil F, Mariatulqabtiah AR, Tan WS, Ho KL, Isa NM, Lau HY, Abu J, Chuang KP. Loop-Mediated Isothermal Amplification (LAMP) as a Promising Point-of-Care Diagnostic Strategy in Avian Virus Research. Animals (Basel) 2021; 12:ani12010076. [PMID: 35011181 PMCID: PMC8744981 DOI: 10.3390/ani12010076] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 12/02/2021] [Accepted: 12/04/2021] [Indexed: 12/16/2022] Open
Abstract
Simple Summary Many of the existing screening methods of avian viruses depend on clinical symptoms and pathological gross examinations that still necessitate confirmatory microscopic testing. Confirmation of a virus is often conducted at centralized laboratories that are well-equipped with instruments for virus isolation, hemagglutinin inhibition, virus neutralization, ELISA, PCR and qPCR. These assays are known for their great accuracy and sensitivity, and hence are set as standard practices. Nevertheless, limitations arise due to the time, cost and on-site applicability. As the technology progresses, molecular diagnostics should be more accessible to isolated areas and even practicable for use by non-skilled personnel such as farmers and private breeders. One of the point-of-care diagnostic strategies to consider for such matters is loop-mediated isothermal amplification (LAMP). Abstract Over the years, development of molecular diagnostics has evolved significantly in the detection of pathogens within humans and their surroundings. Researchers have discovered new species and strains of viruses, while mitigating the viral infections that occur, owing to the accessibility of nucleic acid screening methods such as polymerase chain reaction (PCR), quantitative (real-time) polymerase chain reaction (qPCR) and reverse-transcription qPCR (RT-qPCR). While such molecular detection methods are widely utilized as the benchmark, the invention of isothermal amplifications has also emerged as a reliable tool to improvise on-field diagnosis without dependence on thermocyclers. Among the established isothermal amplification technologies are loop-mediated isothermal amplification (LAMP), recombinant polymerase amplification (RPA), strand displacement activity (SDA), nucleic acid sequence-based amplification (NASBA), helicase-dependent amplification (HDA) and rolling circle amplification (RCA). This review highlights the past research on and future prospects of LAMP, its principles and applications as a promising point-of-care diagnostic method against avian viruses.
Collapse
Affiliation(s)
- Faiz Padzil
- Laboratory of Vaccine and Biomolecules, Institute of Bioscience, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia; (F.P.); (W.S.T.); (N.M.I.)
- Institute for Medical Research, National Institute of Health, Setia Alam, Shah Alam 40170, Selangor, Malaysia
| | - Abdul Razak Mariatulqabtiah
- Laboratory of Vaccine and Biomolecules, Institute of Bioscience, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia; (F.P.); (W.S.T.); (N.M.I.)
- Department of Cell and Molecular Biology, Faculty of Biotechnology and Biomolecular Sciences, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia
- Correspondence: ; Tel.: +60-297-691-938
| | - Wen Siang Tan
- Laboratory of Vaccine and Biomolecules, Institute of Bioscience, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia; (F.P.); (W.S.T.); (N.M.I.)
- Department of Microbiology, Faculty of Biotechnology and Biomolecular Sciences, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia
| | - Kok Lian Ho
- Department of Pathology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia;
| | - Nurulfiza Mat Isa
- Laboratory of Vaccine and Biomolecules, Institute of Bioscience, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia; (F.P.); (W.S.T.); (N.M.I.)
- Department of Cell and Molecular Biology, Faculty of Biotechnology and Biomolecular Sciences, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia
| | - Han Yih Lau
- Biotechnology and Nanotechnology Research Centre, Malaysian Agricultural Research and Development Institute (MARDI), Persiaran MARDI-UPM, Serdang 43400, Selangor, Malaysia;
| | - Jalila Abu
- Department of Veterinary Clinical Studies, Faculty of Veterinary Medicine, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia;
| | - Kuo-Pin Chuang
- International Degree Program in Animal Vaccine Technology, International College, National Pingtung University of Science and Technology, Pingtung 912, Taiwan;
- Graduate Institute of Animal Vaccine Technology, College of Veterinary Medicine, National Pingtung University of Science and Technology, Pingtung 912, Taiwan
- School of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan
- Research Center for Animal Biologics, National Pingtung University of Science and Technology, Pingtung 912, Taiwan
- School of Dentistry, Kaohsiung Medical University, Kaohsiung 807, Taiwan
| |
Collapse
|
14
|
Panpradist N, Kline EC, Atkinson RG, Roller M, Wang Q, Hull IT, Kotnik JH, Oreskovic AK, Bennett C, Leon D, Lyon V, Gilligan-Steinberg SD, Han PD, Drain PK, Starita LM, Thompson MJ, Lutz BR. Harmony COVID-19: A ready-to-use kit, low-cost detector, and smartphone app for point-of-care SARS-CoV-2 RNA detection. SCIENCE ADVANCES 2021; 7:eabj1281. [PMID: 34910507 PMCID: PMC8673764 DOI: 10.1126/sciadv.abj1281] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 10/26/2021] [Indexed: 05/22/2023]
Abstract
RNA amplification tests sensitively detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, but their complexity and cost are prohibitive for expanding coronavirus disease 2019 (COVID-19) testing. We developed “Harmony COVID-19,” a point-of-care test using inexpensive consumables, ready-to-use reagents, and a simple device. Our ready-to-use, multiplexed reverse transcription, loop-mediated isothermal amplification (RT-LAMP) can detect down to 0.38 SARS-CoV-2 RNA copies/μl and can report in 17 min for high–viral load samples (5000 copies/μl). Harmony detected 97 or 83% of contrived samples with ≥0.5 viral particles/μl in nasal matrix or saliva, respectively. Evaluation in clinical nasal specimens (n = 101) showed 100% detection of RNA extracted from specimens with ≥0.5 SARS-CoV-2 RNA copies/μl, with 100% specificity in specimens positive for other respiratory pathogens. Extraction-free analysis (n = 29) had 95% success in specimens with ≥1 RNA copies/μl. Usability testing performed first time by health care workers showed 95% accuracy.
Collapse
Affiliation(s)
- Nuttada Panpradist
- Department of Bioengineering, University of Washington, Seattle, WA, USA
- Global Health for Women, Adolescents, and Children, School of Public Health, University of Washington, Seattle, WA, USA
| | - Enos C. Kline
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Robert G. Atkinson
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Michael Roller
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Qin Wang
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Ian T. Hull
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Jack H. Kotnik
- Department of Bioengineering, University of Washington, Seattle, WA, USA
- Department of Family Medicine, University of Washington, Seattle, WA, USA
| | - Amy K. Oreskovic
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Crissa Bennett
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Daniel Leon
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Victoria Lyon
- Department of Family Medicine, University of Washington, Seattle, WA, USA
| | | | - Peter D. Han
- Department of Genome Sciences, University of Washington, Seattle, WA, USA
- Brotman Baty Institute for Precision Medicine, Seattle, WA, USA
| | - Paul K. Drain
- Departments of Global Health, Medicine, and Epidemiology, University of Washington, Seattle, WA, USA
| | - Lea M. Starita
- Department of Genome Sciences, University of Washington, Seattle, WA, USA
- Brotman Baty Institute for Precision Medicine, Seattle, WA, USA
| | | | - Barry R. Lutz
- Department of Bioengineering, University of Washington, Seattle, WA, USA
- Brotman Baty Institute for Precision Medicine, Seattle, WA, USA
| |
Collapse
|
15
|
Pascual-Garrigos A, Maruthamuthu MK, Ault A, Davidson J, Rudakov G, Pillai D, Koziol J, Schoonmaker JP, Johnson T, Verma MS. On-farm colorimetric detection of Pasteurella multocida, Mannheimia haemolytica, and Histophilus somni in crude bovine nasal samples. Vet Res 2021; 52:126. [PMID: 34600578 PMCID: PMC8487530 DOI: 10.1186/s13567-021-00997-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 09/03/2021] [Indexed: 11/10/2022] Open
Abstract
This work modifies a loop-mediated isothermal amplification (LAMP) assay to detect the bovine respiratory disease (BRD) bacterial pathogens Pasteurella multocida, Mannheimia haemolytica, and Histophilus somni in a colorimetric format on a farm. BRD causes a significant health and economic burden worldwide that partially stems from the challenges involved in determining the pathogens causing the disease. Methods such as polymerase chain reaction (PCR) have the potential to identify the causative pathogens but require lab equipment and extensive sample processing making the process lengthy and expensive. To combat this limitation, LAMP allows accurate pathogen detection in unprocessed samples by the naked eye allowing for potentially faster and more precise diagnostics on the farm. The assay developed here offers 66.7-100% analytical sensitivity, and 100% analytical specificity (using contrived samples) while providing 60-100% concordance with PCR results when tested on five steers in a feedlot. The use of a consumer-grade water bath enabled on-farm execution by collecting a nasal swab from cattle and provided a colorimetric result within 60 min. Such an assay holds the potential to provide rapid pen-side diagnostics to cattle producers and veterinarians.
Collapse
Affiliation(s)
- Ana Pascual-Garrigos
- Department of Agricultural and Biological Engineering, Purdue University, 225 S University Street, West Lafayette, IN 47907 USA
- Department of Biochemistry, Purdue University, 175 South University Street, West Lafayette, IN 47906 USA
- Birck Nanotechnology Center, Purdue University, 1205 W State St, West Lafayette, IN 47907 USA
| | - Murali Kannan Maruthamuthu
- Department of Agricultural and Biological Engineering, Purdue University, 225 S University Street, West Lafayette, IN 47907 USA
- Birck Nanotechnology Center, Purdue University, 1205 W State St, West Lafayette, IN 47907 USA
| | - Aaron Ault
- School of Electrical and Computer Engineering, Purdue University, 465 Northwestern Avenue, West Lafayette, IN 47907 USA
| | - Josiah
Levi
Davidson
- Department of Agricultural and Biological Engineering, Purdue University, 225 S University Street, West Lafayette, IN 47907 USA
- Birck Nanotechnology Center, Purdue University, 1205 W State St, West Lafayette, IN 47907 USA
| | - Grigorii Rudakov
- Department of Agricultural and Biological Engineering, Purdue University, 225 S University Street, West Lafayette, IN 47907 USA
- Birck Nanotechnology Center, Purdue University, 1205 W State St, West Lafayette, IN 47907 USA
- Weldon School of Biomedical Engineering, Purdue University, 206 South Martin Jischke Drive, West Lafayette, IN 47907 USA
| | - Deepti Pillai
- Department of Comparative Pathobiology, Purdue University, 625 Harrison Street, West Lafayette, IN 47907 USA
| | - Jennifer Koziol
- School of Veterinary Medicine, Texas Tech University,
7671 Evans Drive
,
Amarillo
, TX 79106 USA
| | - Jon P. Schoonmaker
- Department of Animal Sciences, Purdue University, 270 S Russell Street, West Lafayette, IN 47907 USA
| | - Timothy Johnson
- Department of Animal Sciences, Purdue University, 270 S Russell Street, West Lafayette, IN 47907 USA
| | - Mohit S. Verma
- Department of Agricultural and Biological Engineering, Purdue University, 225 S University Street, West Lafayette, IN 47907 USA
- Birck Nanotechnology Center, Purdue University, 1205 W State St, West Lafayette, IN 47907 USA
- Weldon School of Biomedical Engineering, Purdue University, 206 South Martin Jischke Drive, West Lafayette, IN 47907 USA
| |
Collapse
|
16
|
Pascual-Garrigos A, Maruthamuthu MK, Ault A, Davidson JL, Rudakov G, Pillai D, Koziol J, Schoonmaker JP, Johnson T, Verma MS. On-farm colorimetric detection of Pasteurella multocida, Mannheimia haemolytica, and Histophilus somni in crude bovine nasal samples. Vet Res 2021; 52:126. [PMID: 34600578 DOI: 10.1021/acsagscitech.0c00072] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 09/03/2021] [Indexed: 05/28/2023] Open
Abstract
This work modifies a loop-mediated isothermal amplification (LAMP) assay to detect the bovine respiratory disease (BRD) bacterial pathogens Pasteurella multocida, Mannheimia haemolytica, and Histophilus somni in a colorimetric format on a farm. BRD causes a significant health and economic burden worldwide that partially stems from the challenges involved in determining the pathogens causing the disease. Methods such as polymerase chain reaction (PCR) have the potential to identify the causative pathogens but require lab equipment and extensive sample processing making the process lengthy and expensive. To combat this limitation, LAMP allows accurate pathogen detection in unprocessed samples by the naked eye allowing for potentially faster and more precise diagnostics on the farm. The assay developed here offers 66.7-100% analytical sensitivity, and 100% analytical specificity (using contrived samples) while providing 60-100% concordance with PCR results when tested on five steers in a feedlot. The use of a consumer-grade water bath enabled on-farm execution by collecting a nasal swab from cattle and provided a colorimetric result within 60 min. Such an assay holds the potential to provide rapid pen-side diagnostics to cattle producers and veterinarians.
Collapse
Affiliation(s)
- Ana Pascual-Garrigos
- Department of Agricultural and Biological Engineering, Purdue University, 225 S University Street, West Lafayette, IN, 47907, USA
- Department of Biochemistry, Purdue University, 175 South University Street, West Lafayette, IN, 47906, USA
- Birck Nanotechnology Center, Purdue University, 1205 W State St, West Lafayette, IN, 47907, USA
| | - Murali Kannan Maruthamuthu
- Department of Agricultural and Biological Engineering, Purdue University, 225 S University Street, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, 1205 W State St, West Lafayette, IN, 47907, USA
| | - Aaron Ault
- School of Electrical and Computer Engineering, Purdue University, 465 Northwestern Avenue, West Lafayette, IN, 47907, USA
| | - Josiah Levi Davidson
- Department of Agricultural and Biological Engineering, Purdue University, 225 S University Street, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, 1205 W State St, West Lafayette, IN, 47907, USA
| | - Grigorii Rudakov
- Department of Agricultural and Biological Engineering, Purdue University, 225 S University Street, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, 1205 W State St, West Lafayette, IN, 47907, USA
- Weldon School of Biomedical Engineering, Purdue University, 206 South Martin Jischke Drive, West Lafayette, IN, 47907, USA
| | - Deepti Pillai
- Department of Comparative Pathobiology, Purdue University, 625 Harrison Street, West Lafayette, IN, 47907, USA
| | - Jennifer Koziol
- School of Veterinary Medicine, Texas Tech University, 7671 Evans Drive , Amarillo , TX, 79106, USA
| | - Jon P Schoonmaker
- Department of Animal Sciences, Purdue University, 270 S Russell Street, West Lafayette, IN, 47907, USA
| | - Timothy Johnson
- Department of Animal Sciences, Purdue University, 270 S Russell Street, West Lafayette, IN, 47907, USA
| | - Mohit S Verma
- Department of Agricultural and Biological Engineering, Purdue University, 225 S University Street, West Lafayette, IN, 47907, USA.
- Birck Nanotechnology Center, Purdue University, 1205 W State St, West Lafayette, IN, 47907, USA.
- Weldon School of Biomedical Engineering, Purdue University, 206 South Martin Jischke Drive, West Lafayette, IN, 47907, USA.
| |
Collapse
|