1
|
Preda A, Melillo F, Baroni M, Marzi A, Schillaci V, Vargiu S, Caccia A, Guarracini F, Gigli L, Paglino G, Massaro G, Diemberger I, Mascioli G, Solimene F, Mazzone P. Multicentric Experience With the Use of Short 13Fr Mechanical Rotating Dilator Sheath for Transvenous Lead Extraction. Pacing Clin Electrophysiol 2025. [PMID: 39913112 DOI: 10.1111/pace.15146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2024] [Revised: 12/06/2024] [Accepted: 01/07/2025] [Indexed: 02/07/2025]
Abstract
BACKGROUND The need for transvenous lead extraction (TLE) is increasing worldwide. Since the course of the subclavian vein until the junction with the superior vena cava is a frequent place of lead adherences, we aim to assess the safety and efficacy of a short 13Fr bidirectional rotational mechanical sheath as first choice. METHODS AND RESULTS In this multicentric study, 202 carriers of a cardiac implantable electronic device (CIED) undergoing TLE using a short 13 Fr bidirectional rotational mechanical sheath were prospectively enrolled. All procedures were performed using a stepwise approach. The indication for TLE were infection (62%), malfunction (32%), and upgrade (6%). Overall, 471 leads were extracted: 65% pacing leads, 20% defibrillator leads, 9% coronary sinus leads, and 6% abandoned leads. Clinical success and complete lead extraction have been achieved in 97% and 95% of cases, respectively. The short sheath was always effective in gaining venous access at the start of the procedure and was sufficient for complete TLE in 67% of cases. Lead dwell time, defibrillator lead, number of leads per patient, and lead malfunction were predicting factors of long bidirectional rotational mechanical sheath use. There were no cases of intraprocedural death, and major complications were reported in 2% of patients. Overall survival was 97% at 1-year follow-up. CONCLUSION This multicentric experience using a short 13Fr bidirectional rotational mechanical sheath reported high safety and efficacy, demonstrating the utility of routine use of short extraction sheaths of higher caliper as the first choice.
Collapse
Affiliation(s)
- Alberto Preda
- De Gasperis Cardio Center, Electrophysiology Unit, Niguarda Hospital, Milan, Italy
| | | | - Matteo Baroni
- De Gasperis Cardio Center, Electrophysiology Unit, Niguarda Hospital, Milan, Italy
| | - Alessandra Marzi
- Department of Cardiac Electrophysiology, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | | | - Sara Vargiu
- De Gasperis Cardio Center, Electrophysiology Unit, Niguarda Hospital, Milan, Italy
| | - Andrea Caccia
- De Gasperis Cardio Center, Electrophysiology Unit, Niguarda Hospital, Milan, Italy
| | - Fabrizio Guarracini
- De Gasperis Cardio Center, Electrophysiology Unit, Niguarda Hospital, Milan, Italy
| | - Lorenzo Gigli
- De Gasperis Cardio Center, Electrophysiology Unit, Niguarda Hospital, Milan, Italy
| | - Gabriele Paglino
- Department of Cardiac Electrophysiology, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Giulia Massaro
- Department of Experimental, Diagnostic and Specialty Medicine, S. Orsola Hospital, Cardio-Thoracic and Vascular Building, Bologna, Italy
| | - Igor Diemberger
- Department of Experimental, Diagnostic and Specialty Medicine, S. Orsola Hospital, Cardio-Thoracic and Vascular Building, Bologna, Italy
| | - Giosuè Mascioli
- Cardiothoracic Department, Humanitas Gavazzeni, Bergamo, Italy
| | | | - Patrizio Mazzone
- De Gasperis Cardio Center, Electrophysiology Unit, Niguarda Hospital, Milan, Italy
| |
Collapse
|
2
|
Kutarski A, Jacheć W, Pietura R, Czajkowski M, Stefańczyk P, Kosior J, Sawonik S, Nowosielecka D. Removal of Spontaneously Fractured Leads with Their Proximal Ends in the Heart and Vasculature-Description of Different Approaches and Tools. J Clin Med 2025; 14:282. [PMID: 39797364 PMCID: PMC11720824 DOI: 10.3390/jcm14010282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2024] [Revised: 11/23/2024] [Accepted: 12/12/2024] [Indexed: 01/13/2025] Open
Abstract
Background: Removal of spontaneously fractured leads with their proximal ends migrated into the vascular space has not been analysed in detail thus far. The study aimed to compare the effectiveness of different approaches and auxiliary tools for removing fractured leads with migrated proximal ends. Methods: Retrospective analysis of 72 cases from a database containing 3847 TLEs (transvenous lead extraction). Results: Most of the leads were passive, especially unipolar. Procedure complexity in such cases was high but with satisfying effectiveness (procedural success rate 93.06%) and independent of the position of the proximal end. The rate of major complications was 2.78%, which may be attributed to long implant duration (152.2 months). Extraction of such leads did not influence long-term survival. The femoral approach was most often used (62.50%). In 79.16% of leads, mechanical dissection was required. In 66.7%, proximal ends were strongly attached to the wall, and a loop had to be applied. In 15.28% of procedures, the lead was wrapped around a pig-tail catheter ("spaghetti twisting technique"). Conclusions: (1) Spontaneous lead fracture with the proximal ends migrated into the vascular space is a rare finding (1.87% of the TLE). (2) Removal of such leads requires the use of different approaches as well as dedicated and non-dedicated tools. (3) Despite a high level of procedure complexity, its effectiveness is high, with an acceptable rate of major complications.
Collapse
Affiliation(s)
- Andrzej Kutarski
- Department of Cardiology, University Hospital of Lublin, 20-059 Lublin, Poland; (A.K.); (S.S.)
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-055 Katowice, Poland;
| | - Radosław Pietura
- Department of Radiography, Medical University of Lublin, 20-059 Lublin, Poland;
| | - Marek Czajkowski
- Department of Cardiac Surgery, Medical University of Lublin, 20-059 Lublin, Poland;
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamosc, Poland;
| | - Jarosław Kosior
- Department of Cardiology, Masovian Specialistic Hospital of Radom, 26-617 Radom, Poland;
| | - Sebastian Sawonik
- Department of Cardiology, University Hospital of Lublin, 20-059 Lublin, Poland; (A.K.); (S.S.)
| | - Dorota Nowosielecka
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamosc, Poland
- Institute of Humanities and Medicine, Academy of Zamość, 22-400 Zamosc, Poland
| |
Collapse
|
3
|
Khallikane S, Mehdi N, Didi M, Kbiri H, Qamouss Y. Elective Sternotomy With Fluoroscopic Guidance for the Removal of a Residual Implantable Cardioverter Defibrillator Lead: A Case Report and Literature Review. Cureus 2025; 17:e77148. [PMID: 39817263 PMCID: PMC11732613 DOI: 10.7759/cureus.77148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/08/2025] [Indexed: 01/18/2025] Open
Abstract
Infectious myocarditis (IM) and infective endocarditis (IE), sometimes associated with infection of the surrounding mediastinal tissue or embolic complications caused by residual implantable cardioverter defibrillator (ICD) lead material embedded in the ventricle, present a significant challenge for cardiac surgeons due to the difficulty of precisely locating the old intracardiac pacing lead remnants because of the heart's continuous movement. We present the case of successful two-stage elective sternotomy extraction of two residual defibrillator leads, one trapped in the left innominate vein, easily removed after veinotomy without cardiopulmonary bypass (CPB), and the other embedded intramyocardially in the inferior wall of the right ventricle, successfully removed under CPB after fluoroscopic guidance. The patient was discharged four weeks post-operation without complications. In our case, transesophageal echocardiography (TEE) was not performed due to the patient's history of esophageal achalasia.
Collapse
Affiliation(s)
- Said Khallikane
- Anesthesiology and Critical Care, Military Hospital of Avicenne, Marrakech, MAR
| | - Nabil Mehdi
- Anesthesiology and Critical Care, Faculty of Medicine and Pharmacy of Rabat, Rabat, MAR
| | - Mehdi Didi
- Anesthesiology and Critical Care, Mohammed V Military Instruction Hospital, Rabat, MAR
| | - Hicham Kbiri
- Anesthesiology, Intensive Care Unit, and Emergency, Military Hospital of Avicenne, Marrakech, MAR
| | - Youssef Qamouss
- Anesthesiology and Reanimation, Military Hospital of Avicenne, Marrakech, MAR
| |
Collapse
|
4
|
Kutarski A, Miszczak-Knecht M, Brzezinska M, Birbach M, Lipiński W, Jacheć W, Ziaja B, Polewczyk A, Tułecki Ł, Czajkowski M, Nowosielecka D, Bieganowska K. Lead Extraction in Children and Young Adults: When is the Best Time for Lead/System Replacement? Pediatr Cardiol 2025; 46:61-71. [PMID: 37898588 PMCID: PMC11753338 DOI: 10.1007/s00246-023-03320-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Accepted: 10/03/2023] [Indexed: 10/30/2023]
Abstract
The best strategy for lead management in children is a matter of debate, and our experiences are limited. This is a retrospective single-center study comparing difficulties and outcomes of transvenous lead extraction (TLE) implanted ich childhood and at age < 19 years (childhood-implanted-childhood-extracted, CICE) and at age < 19 (childhood-implanted-adulthood-extracted, CIAE). CICE patients-71 children (mean age 15.1 years) as compared to CIAE patients (114 adults (mean age 28.61 years) were more likely to have VVI than DDD pacemakers. Differences in implant duration (7.96 vs 14.08 years) appeared to be most important, but procedure complexity and outcomes also differed between the groups. Young adults with cardiac implantable electronic device implanted in childhood had more risk factors for major complications and underwent more complex procedures compared to children. Implant duration was significantly longer in CIAE patients than in children, being the most important factor that had an impact on patient safety and procedure complexity. CIAE patients were more likely to have prolonged operative duration and more complex procedures due to technical problems, and they were 2-3 times more likely to require second-line or advanced tools compared to children, but the rates of clinical and procedural success were comparable in both groups. The difference between the incidence of major complications between CICE and CIAE patients is very clear (MC 2.9 vs 7.0%, hemopericardium 1.4 vs 5.3% etc.), although statistically insignificant. Delay of lead extraction to adulthood seems to be a riskier option than planned TLE in children before growing up.
Collapse
Affiliation(s)
- Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin, Lublin, Poland
| | | | - Monika Brzezinska
- Department of Cardiology, Children's Memorial Health Institute, Warsaw, Poland
| | - Mariusz Birbach
- Department of Cardiac Surgery, Children's Memorial Health Institute, Warsaw, Poland
| | - Wojciech Lipiński
- Department of Cardiac Surgery, Children's Memorial Health Institute, Warsaw, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland
| | - Bettina Ziaja
- Department of Cardiology, Specialist Hospital in Zabrze, Zabrze, Poland
| | - Anna Polewczyk
- Department of Medicine and Health Sciences, The Jan Kochanowski University, Kielce, Poland
| | - Łukasz Tułecki
- Department of Cardiac Surgery, Pope John Paul II Province Hospital, Zamość, Poland
| | - Marek Czajkowski
- Department of Cardiac Surgery, Medical University of Lublin, Lublin, Poland
| | - Dorota Nowosielecka
- Department of Cardiac Surgery, Pope John Paul II Province Hospital, Zamość, Poland.
- Department of Cardiology, Pope John Paul II Province Hospital, Aleje Jana Pawła II 10, 22-400, Zamość, Poland.
| | | |
Collapse
|
5
|
Zhao Y, Su L, Gao Y, Wang H, Luan C, Liu J, Chen F. Leadless pacemaker implantation after delayed atrial lead perforation and battery depletion: a case report. BMC Cardiovasc Disord 2024; 24:747. [PMID: 39731020 DOI: 10.1186/s12872-024-04448-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2024] [Accepted: 12/20/2024] [Indexed: 12/29/2024] Open
Abstract
BACKGROUND Delayed lead perforation is a rare complication of cardiac implantable electronic device (CIED). Clinical presentations range from completely asymptomatic to pericardial tamponade. Surgical lead extraction is recommended and transvenous lead extraction (TLE) with surgical backup is an alternative method. CASE PRESENTATION A male with paroxysmal atrial fibrillation and sick sinus syndrome implanted a dual-chamber pacemaker with two passive fixation lead. He was on oral anticoagulants and played golf for almost 1 h every day after implantation. However, he complained of thoracic stabbing in the sternal manubrium with abnormal findings on pacemaker interrogation. Imaging confirmed the perforated atrial electrode with lead tip protrusion from the pericardium adjacent to the inferior wall of the main right pulmonary artery, but without pericardial effusion. Lead removal by TLE with surgical support was suggested, but he refused. Given the stable conditions, conservative treatment was chosen in the absence of complications during a follow-up period of 14 years. Then ventricular lead failure and battery depletion appeared and a leadless pacemaker was implanted. CONCLUSIONS Chest pain in CIED with abnormal electrical parameters, especially ongoing treatment with anticoagulants and regular physical activity, should always raise suspicion of lead perforation. A conservative strategy may be appropriate and feasible for those in the absence of perforation-related complications. For patients with noninfectious abandoned leads and battery depletion after CIED, leadless pacemaker may be an alternative approach according to patient and provider preferences.
Collapse
Affiliation(s)
- Yichang Zhao
- Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Liping Su
- Department of Nursing, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Yuchen Gao
- Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Hao Wang
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Chao Luan
- Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Jinqiu Liu
- Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China.
| | - Feifei Chen
- Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China.
| |
Collapse
|
6
|
Hu TY, Montgomery JA. How to Approach Patients with Cardiac Implantable Electronic Devices and Bacteremia. Card Electrophysiol Clin 2024; 16:373-382. [PMID: 39461828 DOI: 10.1016/j.ccep.2024.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/29/2024]
Abstract
The approach to a patient with a cardiac implantable electronic device (CIED) and bacteremia requires a high index of suspicion. The microorganism and duration of bacteremia affect the pretest probability of CIED infection. When transesophageal echocardiography findings are equivocal, fluorodeoxyglucose-PET/computed tomography can increase the sensitivity and specificity for CIED infection. Confirmed CIED infection warrants complete system extraction. In patients with persistent gram-positive bacteremia despite antimicrobial therapy and unclear involvement of the CIED, the device is sometimes empirically extracted. Long-term effects of extraction (such as risk of suboptimal/failed cardiac resynchronization therapy reimplant) should be factored into decisions regarding empiric CIED extraction.
Collapse
Affiliation(s)
- Tiffany Ying Hu
- Division of Cardiovascular Medicine, Arrhythmia Section, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Jay Alan Montgomery
- Division of Cardiovascular Medicine, Arrhythmia Section, Vanderbilt University Medical Center, Nashville, TN, USA.
| |
Collapse
|
7
|
Schaller RD, Zeitler EP, Kroman A. Lead Extraction History, Training, Volume, and Location. Card Electrophysiol Clin 2024; 16:393-402. [PMID: 39461830 DOI: 10.1016/j.ccep.2024.07.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/29/2024]
Abstract
Transvenous lead extraction (TLE) has evolved significantly since the introduction of cardiac pacing systems in the 1950s. The need for TLE has grown due to the increasing complexity of cardiac devices and patients, alongside rising infection rates and regulatory recalls. Despite its challenges, improved institutional support and advanced training programs have made TLE more accessible. Modern TLE indications are well-defined, evolving through scientific statements to include comprehensive lead management best practices and safety protocols. However, underutilization persists, particularly in infection management, highlighting the need for continued education and adherence to guidelines.
Collapse
Affiliation(s)
- Robert D Schaller
- Division of Cardiovascular Medicine, Department of Medicine, Cardiac Electrophysiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA.
| | - Emily P Zeitler
- Department of Medicine, The Geisel School of Medicine at Dartmouth, Hanover, NH, USA
| | - Anne Kroman
- Division of Cardiology, Department of Medicine, Medical University of South Carolina, 30 Courtenay Drive, Charleston, SC 29425, USA
| |
Collapse
|
8
|
Nowosielecka D, Jacheć W, Stefańczyk Dzida M, Polewczyk A, Mościcka D, Nowosielecka A, Kutarski A. What Important Information Does Transesophageal Echocardiography Provide When Performed before Transvenous Lead Extraction? J Clin Med 2024; 13:5278. [PMID: 39274491 PMCID: PMC11396690 DOI: 10.3390/jcm13175278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 08/25/2024] [Accepted: 09/02/2024] [Indexed: 09/16/2024] Open
Abstract
Background: Transesophageal echocardiography (TEE) is mandatory before transvenous lead extraction (TLE), but its usefulness remains underestimated. This study aims to describe the broad range of TEE findings in TLE candidates, as well as their influence on procedure complexity, major complications (MCs) and long-term survival. Methods: Preoperative TEE was performed in 1191 patients undergoing TLE. Results: Lead thickening (OR = 1.536; p = 0.007), lead adhesion to heart structures (OR = 2.531; p < 0.001) and abnormally long lead loops (OR = 1.632; p = 0.006) increased the complexity of TLE. Vegetation-like masses on the lead (OR = 4.080; p = 0.44), lead thickening (OR = 2.389; p = 0.049) and lead adhesion to heart structures (OR = 6.341; p < 0.001) increased the rate of MCs. The presence of vegetations (HR = 7.254; p < 0.001) was the strongest predictor of death during a 1-year follow-up period. Conclusions: TEE before TLE provides a lot of important information for the operator. Apart from the visualization of possible vegetations, it can also detect various forms of lead-related scar tissue. Build-up of scar tissue and the presence of long lead loops are associated with increased complexity of the procedure and risk of MCs. Preoperative TEE performed outside the operating room may have an impact on the clinical decision-making process, such as transferring potentially more difficult patients to a more experienced center or having the procedure performed by the most experienced operator. Moreover, the presence of masses or vegetations on the leads significantly increases 1-year and all-cause mortality.
Collapse
Affiliation(s)
- Dorota Nowosielecka
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
- Department of Cardiology, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, 41-800 Zabrze, Poland
| | | | - Anna Polewczyk
- Department of Physiology, Pathopysiology and Clinical Immunology, Collegium Medicum of Jan Kochanowski University, 25-369 Kielce, Poland
- Department of Cardiac Surgery, Swietokrzyskie Cardiology Center, 25-736 Kielce, Poland
| | - Dominika Mościcka
- Internal Medicine Residency Program, Tallahassee Memorial HealthCare, Florida State University, 1300 Miccosukee Road Tallahassee, Tallahassee, FL 32308, USA
| | - Agnieszka Nowosielecka
- Department of Internal Medicine and Geriatrics, The A. Falkiewicz Specialist Hospital, 52-114 Wrocław, Poland
| | - Andrzej Kutarski
- Department of Cardiology, Medical University, 20-059 Lublin, Poland
| |
Collapse
|
9
|
Patel K, Toomu S, Lee E, Darden D, Jacobs K, Pollema T, Ho G, Birgersdotter-Green U. Computed tomography predictors of increased transvenous lead extraction difficulty. Pacing Clin Electrophysiol 2024; 47:1232-1240. [PMID: 38967391 DOI: 10.1111/pace.15034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 05/19/2024] [Accepted: 06/18/2024] [Indexed: 07/06/2024]
Abstract
BACKGROUND The ability of computed tomography (CT) characteristics to predict the difficulty of transvenous lead extraction (TLE) is an evolving subject. OBJECTIVE To identify CT characteristics associated with increased TLE difficulty. METHODS All consecutive patients undergoing TLE at the University of California San Diego from January 2018 to February 2022 were analyzed, utilizing the UC San Diego Lead Extraction Registry. Patients underwent cardiac-gated chest CT scans with intravenous contrast; all scans were reviewed by a single radiologist. Lead extraction was performed per standard institutional protocol with the initial use of a laser sheath and crossover to a mechanical sheath as needed. Multivariable linear and logistic regression analyses were performed to identify predictors of individual lead-removal fluoroscopy time and mechanical sheath use, as markers of extraction difficulty. RESULTS A total of 343 patients were analyzed. The mean age of the study population was 63.8 ± 15.4 years; 71% were male. The mean lead dwell-in duration was 8.6 ± 5.7 years. In multivariable linear regression analysis, venous occlusion detected on CT was independently associated with higher individual lead-removal fluoroscopy time (p = 0.004), when adjusting for clinical characteristics such as lead dwell time. In multivariable logistic regression analysis, calcification and venous occlusion were independently associated with a higher need for mechanical sheath use during TLE (odds ratio:5.08, p < 0.001, 95% CI: 2.54-10.46) and (odds ratio:3.72, p < 0.001, 95% CI: 1.89-7.35), respectively. CONCLUSION In patients undergoing TLE, venous occlusion identified by chest CT is associated with increased fluoroscopy time. Patients with lead-associated calcification or venous occlusion detected by chest CT are each five and three times more likely to require crossover from laser to a mechanical sheath.
Collapse
Affiliation(s)
- Kavisha Patel
- Department of Cardiology, University of California San Diego, La Jolla, California, USA
| | - Sandeep Toomu
- Department of Cardiology, University of California San Diego, La Jolla, California, USA
| | - Euyhyun Lee
- Department of Cardiology, University of California San Diego, La Jolla, California, USA
| | - Douglas Darden
- Department of Cardiology, Kansas City Heart Rhythm Institute, Kansas City, Kansas, USA
| | - Kathleen Jacobs
- Department of Cardiology, University of California San Diego, La Jolla, California, USA
| | - Travis Pollema
- Department of Cardiology, University of California San Diego, La Jolla, California, USA
| | - Gordon Ho
- Department of Cardiology, University of California San Diego, La Jolla, California, USA
| | | |
Collapse
|
10
|
Li L, Busija A, Feng H, Pandey AC, Le Jemtel T, Wanna BG. Effective and safe mechanical transvenous lead extraction in a low-volume center. Heart Rhythm O2 2024; 5:639-643. [PMID: 39493906 PMCID: PMC11524931 DOI: 10.1016/j.hroo.2024.07.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2024] Open
Abstract
Background Transvenous lead extraction (TLE) of cardiac implantable electronic devices was once deemed highly risky by high-volume centers. However, advancements in technology have significantly reduced the risk, making TLE a safer procedure in electrophysiology. Objective The purpose of this study was to examine the efficacy and safety of mechanical TLEs in a low-volume center with a single operator. Methods This study retrospectively accessed electronic medical records from the Tulane University School of Medicine system in New Orleans, Louisiana, and included patients who received mechanical TLE from 2016 to 2023. We analyzed the indications for TLE, patient characteristics, lead characteristics, success rate, and complications. Results We included 149 consecutive mechanical TLEs with an average implant duration of 105 months. A total of 53.7% (80) of TLEs were indicated for infectious reasons, and 37.6% (56) were high-voltage leads. Clinical success and complete procedural success rates were both 94.6% with no procedure-related mortality or major complications. The periprocedural mortality rate was 1.25% (1). Minor complications included a left chest pocket hematoma, a left groin hematoma, and urinary retention. Conclusion The efficacy and safety of mechanical TLEs performed in a low-volume center are comparable with those in high-volume centers.
Collapse
Affiliation(s)
- Lin Li
- Department of Cardiology, Tulane University School of Medicine, New Orleans, Louisiana
| | - Anna Busija
- Department of Medicine, Tulane University School of Medicine, New Orleans, Louisiana
| | - Han Feng
- Tulane Research Innovation for Arrhythmia Discovery, Tulane University School of Medicine, New Orleans, Louisiana
| | - Amitabh C. Pandey
- Department of Cardiology, Tulane University School of Medicine, New Orleans, Louisiana
- Department of Cardiology, Southeast Louisiana Veteran Health Care System, New Orleans, Louisiana
| | - Thierry Le Jemtel
- Department of Cardiology, Tulane University School of Medicine, New Orleans, Louisiana
| | - Bassam G. Wanna
- Department of Cardiology, Tulane University School of Medicine, New Orleans, Louisiana
| |
Collapse
|
11
|
Meier C, Israel C, Eisenblätter M, Hoyer A, Stoye FV, Yilmaz A, Gielen S. Safety of magnetic resonance imaging in patients with cardiac implantable electronic devices and abandoned or epicardial leads: a systematic review and meta-analysis. Europace 2024; 26:euae165. [PMID: 38918179 PMCID: PMC11200101 DOI: 10.1093/europace/euae165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Accepted: 06/09/2024] [Indexed: 06/27/2024] Open
Abstract
AIMS Persistent reluctance to perform magnetic resonance imaging (MRI) in patients with abandoned and/or epicardial leads of cardiac implantable electronic devices is related to in vitro studies reporting tip heating. While there is a plethora of data on the safety of MRI in conditional and non-conditional implantable devices, there is a clear lack of safety data in patients with abandoned and/or epicardial leads. METHODS AND RESULTS Relevant literature was identified in Medline and CINAHL using the key terms 'magnetic resonance imaging' AND 'abandoned leads' OR 'epicardial leads'. Secondary literature and cross-references were supplemented. For reporting guidance, the Preferred Reporting Items for Systematic reviews and Meta-Analyses 2020 was used. International Prospective Register of Systematic Reviews (PROSPERO) registration number 465530. Twenty-one publications with a total of 656 patients with 854 abandoned and/or epicardial leads and 929 MRI scans of different anatomical regions were included. No scan-related major adverse cardiac event was documented, although the possibility of under-reporting of critical events in the literature should be considered. Furthermore, no severe device dysfunction or severe arrhythmia was reported. Mainly transient lead parameter changes were observed in 2.8% in the subgroup of patients with functional epicardial leads. As a possible correlate of myocardial affection, subjective sensations occurred mainly in the subgroup with abandoned epicardial leads (4.0%), but no change in myocardial biomarkers was observed. CONCLUSION Existing publications did not report any relevant adverse events for MRI in patients with abandoned and/or epicardial leads if performed according to strict safety guidelines. However, a more rigorous risk-benefit calculation should be made for patients with epicardial leads.
Collapse
Affiliation(s)
- Claudia Meier
- Campus Klinikum Lippe, Universitätsklinikum Ostwestfalen-Lippe, Universitätsklinik für Kardiologie, Angiologie und Internistische Intensivmedizin, Röntgenstraße 18, 32756 Detmold, Germany
- Medizinische Fakultät, Universität Bielefeld, Postfach 10 01 31, 33501 Bielefeld, Germany
| | - Carsten Israel
- Klinik für Innere Medizin, Kardiologie, Nephrologie und Diabetologie, Evangelisches Klinikum Bethel, Bielefeld, Germany
| | - Michel Eisenblätter
- Medizinische Fakultät, Universität Bielefeld, Postfach 10 01 31, 33501 Bielefeld, Germany
- Campus Klinikum Lippe, Universitätsklinikum Ostwestfalen-Lippe, Universitätsinstitut für Diagnostische und Interventionelle Radiologie, Detmold, Germany
| | - Annika Hoyer
- Medizinische Fakultät, Universität Bielefeld, Postfach 10 01 31, 33501 Bielefeld, Germany
- Institut für Biostatistik und Medizinische Biometrie, Universität Bielefeld, Bielefeld, Germany
| | - Ferdinand Valentin Stoye
- Medizinische Fakultät, Universität Bielefeld, Postfach 10 01 31, 33501 Bielefeld, Germany
- Institut für Biostatistik und Medizinische Biometrie, Universität Bielefeld, Bielefeld, Germany
| | - Ali Yilmaz
- Herz-MRT-Zentrum, Universitätsklinikum Münster, Münster, Germany
| | - Stephan Gielen
- Campus Klinikum Lippe, Universitätsklinikum Ostwestfalen-Lippe, Universitätsklinik für Kardiologie, Angiologie und Internistische Intensivmedizin, Röntgenstraße 18, 32756 Detmold, Germany
- Medizinische Fakultät, Universität Bielefeld, Postfach 10 01 31, 33501 Bielefeld, Germany
| |
Collapse
|
12
|
Igbinomwanhia E, Jiwani S, Karim S, Pimentel R. Case Series and Review of Literature for Superior Vena Cava Injury During Laser Lead Extraction. Card Electrophysiol Clin 2024; 16:117-124. [PMID: 38749629 DOI: 10.1016/j.ccep.2023.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2024]
Abstract
Transvenous laser lead extraction poses a risk of major complications (0.19%-1.8%), notably injury to the superior vena cava (SVC) in 0.19% to 0.96% of cases. Various factors contribute to SVC injury, which can be categorized as patient-related (such as female gender, low body mass index, diabetes, renal problems, anemia, and reduced ejection fraction), device-related (including the number, dwell time, and type of leads), or procedural-related (such as reason for extraction, venous obstructions, and bilateral lead placements).
Collapse
Affiliation(s)
- Efehi Igbinomwanhia
- Heart and Vascular Institute, MetroHealth Medical Center/Case Western Reserve University, 2500 Metrohealth Drive, Cleveland, OH 44109, USA.
| | - Sania Jiwani
- Department of Cardiovascular Medicine, University of Kansas Medical Center, 3901 Rainbow Boulevard, Mailstop 4023, Kansas City, KS 66160, USA
| | - Saima Karim
- Heart and Vascular Institute, MetroHealth Medical Center/Case Western Reserve University, 2500 Metrohealth Drive, Cleveland, OH 44109, USA
| | - Rhea Pimentel
- Department of Cardiovascular Medicine, University of Kansas Medical Center, 3901 Rainbow Boulevard, Mailstop 4023, Kansas City, KS 66160, USA
| |
Collapse
|
13
|
Lacharite-Roberge AS, Patel K, Yang Y, Birgersdotter-Green U, Pollema TL. Open Chest Approach Lead Extraction in a Patient with a Large Vegetation: The Importance of Multidisciplinary Approach, Advanced Imaging, and Procedural Planning. Card Electrophysiol Clin 2024; 16:143-147. [PMID: 38749633 DOI: 10.1016/j.ccep.2023.10.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2024]
Abstract
We present a complex case of cardiac implantable electronic device infection and extraction in the setting of bacteremia, large lead vegetation, and patent foramen ovale. Following a comprehensive preprocedural workup including transesophageal echocardiogram and computed tomography lead extraction protocol, in addition to the involvement of multiple subspecialties, an open chest approach to extraction was deemed a safer option for eradication of the patient's infection. Despite percutaneous techniques having evolved as the preferred extraction method during the last few decades, this case demonstrates the importance of a thorough evaluation at an experienced center to determine the need for open chest extraction.
Collapse
Affiliation(s)
- Anne-Sophie Lacharite-Roberge
- Division of Cardiology, Section of Electrophysiology, University of California San Diego, 9452 Medical Center Drive, La Jolla, CA 92037, USA.
| | - Kavisha Patel
- Division of Cardiology, Section of Electrophysiology, University of California San Diego, 9452 Medical Center Drive, La Jolla, CA 92037, USA
| | - Yang Yang
- Division of Cardiology, Section of Electrophysiology, University of California San Diego, 9452 Medical Center Drive, La Jolla, CA 92037, USA
| | - Ulrika Birgersdotter-Green
- Division of Cardiology, Section of Electrophysiology, University of California San Diego, 9452 Medical Center Drive, La Jolla, CA 92037, USA
| | - Travis L Pollema
- Division of Cardiovascular and Thoracic Surgery, University of California San Diego, 9452 Medical Center Drive, La Jolla, CA 92037, USA
| |
Collapse
|
14
|
Asai M, Kiyokuni M, Hiroki U, Ishii K, Tokoro T, Ishikawa H, Kagimoto M, Kataoka S, Kuji S, Nakachi T, Endo T, Hibi K. Successful left ventricular lead placement by way of an azygos vein for a patient performing cardiac resynchronization therapy implantation with an occluded left subclavian vein: A case report. Pacing Clin Electrophysiol 2024; 47:815-819. [PMID: 37793047 DOI: 10.1111/pace.14834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 09/13/2023] [Accepted: 09/20/2023] [Indexed: 10/06/2023]
Abstract
Central venous obstruction following pacemaker implantation is not uncommon and can prove challenging in the case of a system upgrade to a cardiac resynchronization therapy pacemaker (CRT-P). We describe the case of a patient who underwent a successful upgrading procedure of a pacemaker to a CRT-P in the presence of an occluded left subclavian vein and superior vena cava, using collateral veins that drained into right atrium.
Collapse
Affiliation(s)
- Masanari Asai
- Department of Cardiology, Saiseikai Yokohamashi Nanbu Hospital, Yokohama, Japan
- Department of Cardiology, Kanagawa Prefectural Ashigarakami Hospital, Ashigarakamigun, Japan
| | - Masayoshi Kiyokuni
- Department of Cardiology, Saiseikai Yokohamashi Nanbu Hospital, Yokohama, Japan
| | - Uemura Hiroki
- Department of Cardiology, Saiseikai Yokohamashi Nanbu Hospital, Yokohama, Japan
| | - Kazuho Ishii
- Department of Cardiology, Saiseikai Yokohamashi Nanbu Hospital, Yokohama, Japan
| | - Takumi Tokoro
- Department of Cardiology, Saiseikai Yokohamashi Nanbu Hospital, Yokohama, Japan
| | - Hiroyuki Ishikawa
- Department of Cardiology, Kanagawa Prefectural Ashigarakami Hospital, Ashigarakamigun, Japan
| | - Minako Kagimoto
- Department of Cardiology, Saiseikai Yokohamashi Nanbu Hospital, Yokohama, Japan
| | - Shunsuke Kataoka
- Department of Cardiology, Saiseikai Yokohamashi Nanbu Hospital, Yokohama, Japan
| | - Syotaro Kuji
- Department of Cardiology, Saiseikai Yokohamashi Nanbu Hospital, Yokohama, Japan
| | - Tatsuya Nakachi
- Department of Cardiology, Saiseikai Yokohamashi Nanbu Hospital, Yokohama, Japan
| | - Tsutomu Endo
- Department of Cardiology, Saiseikai Yokohamashi Nanbu Hospital, Yokohama, Japan
| | - Kiyoshi Hibi
- Department of Cardiology, Yokohama City University Hospital, Yokohama, Japan
| |
Collapse
|
15
|
Lacharite-Roberge AS, Toomu S, Aldaas O, Ho G, Pollema TL, Birgersdotter-Green U. Inflammatory biomarkers as predictors of systemic vs isolated pocket infection in patients undergoing transvenous lead extraction. Heart Rhythm O2 2024; 5:289-293. [PMID: 38840769 PMCID: PMC11148492 DOI: 10.1016/j.hroo.2024.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2024] Open
Abstract
Background Cardiovascular implantable electronic device (CIED) infections are a common indication for device extraction. Early diagnosis and complete system removal are crucial to reduce morbidity and mortality. The lack of clear infectious symptoms makes the diagnosis of pocket infections challenging and may delay referral for extraction. Objective We aimed to determine if inflammatory biomarkers can help diagnose CIED isolated pocket infection. Methods We performed a retrospective analysis of all patients undergoing transvenous lead extraction for CIED infection at the University of California San Diego from 2012 to 2022 (N = 156). Patients were classified as systemic infection (n = 88) or isolated pocket infection (n = 68). Prospectively collected preoperative procalcitonin (PCT), C-reactive protein, and white blood cell count were compared between groups. Results Pairwise comparisons revealed that the systemic infection group had a higher PCT than the control group (P < .001) and the pocket infection group (P = .009). However, there was no significant difference in PCT value between control subjects and isolated pocket infection subjects. Higher white blood cell count was only associated with systemic infection when compared with our control group (P = .018). Conclusion In patients diagnosed with CIED infections requiring extraction, inflammatory biomarkers were not elevated in isolated pocket infection. Inflammatory markers are not predictive of the diagnosis of pocket infections, which ultimately requires a high level of clinical suspicion.
Collapse
Affiliation(s)
- Anne-Sophie Lacharite-Roberge
- Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, University of California San Diego, San Diego, California
| | - Sandeep Toomu
- Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, University of California San Diego, San Diego, California
| | - Omar Aldaas
- Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, University of California San Diego, San Diego, California
| | - Gordon Ho
- Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, University of California San Diego, San Diego, California
| | - Travis L. Pollema
- Division of Cardiovascular and Thoracic Surgery, University of California San Diego, San Diego, California
| | - Ulrika Birgersdotter-Green
- Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, University of California San Diego, San Diego, California
| |
Collapse
|
16
|
Kutarski A, Jacheć W, Pietura R, Stefańczyk P, Kosior J, Czajkowski M, Sawonik S, Tułecki Ł, Nowosielecka D. Leads with the Cut Proximal Ends Migrated into the Heart and Vasculature: A Rare Phenomenon among 3847 Lead Extraction Procedures. J Clin Med 2024; 13:2602. [PMID: 38731132 PMCID: PMC11084147 DOI: 10.3390/jcm13092602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Revised: 04/09/2024] [Accepted: 04/26/2024] [Indexed: 05/13/2024] Open
Abstract
Background: The study aimed to describe the phenomenon of leads migrated (MPLE) into the cardiovascular system (CVS). Methods: Retrospective analysis of 3847 transvenous lead extractions (TLE). Results: Over a 17-year period, 72 (1.87%) MPLEs (median dwell time 137.5 months) were extracted, which included mainly ventricular leads (56.94%). Overall, 68.06% of MPLEs had their cut proximal ends in the venous system. Most of them were pacing (95.83%) and passive fixation (98.61%) leads. Independent risk factors for MPLE included abandoned leads (OR = 8.473; p < 0.001) and leads located on both sides of the chest (2.981; p = 0.045). The higher NYHA class lowered the probability of MPLE (OR = 0.380; p < 0.001). Procedure complexity was higher in the MPLE group (procedure duration, unexpected procedure difficulties, use of additional (advanced) tools and alternative venous approach). There were no more major complications in the MPLE group, but the rate of procedural success was lower due to more frequent retention of non-removable lead fragments. Extraction of MPLEs did not influence long-term survival. Conclusions: 1. Extraction of leads with MPLE is rare among other TLE procedures (1.9%), 2. risk factors include abandoned leads and presence of leads on both sides of the chest but a higher NYHA class lowers the probability of MPLE, 3. complexity of MPLE extraction is higher regarding procedure duration, unexpected procedure difficulties, use of advanced tools and techniques but rates of major complications are comparable, and 4. extraction of MPLEs did not influence long-term survival.
Collapse
Affiliation(s)
- Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin, 20-093 Lublin, Poland; (A.K.)
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-055 Katowice, Poland
| | - Radosław Pietura
- Department of Radiography, Medical University of Lublin, 20-093 Lublin, Poland
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
| | - Jarosław Kosior
- Department of Cardiology, Masovian Specialistic Hospital of Radom, 26-617 Radom, Poland
| | - Marek Czajkowski
- Department of Cardiac Surgery, Medical University of Lublin, 20-093 Lublin, Poland
| | - Sebastian Sawonik
- Department of Cardiology, Medical University of Lublin, 20-093 Lublin, Poland; (A.K.)
| | - Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
| |
Collapse
|
17
|
Kutarski A, Jacheć W, Czajkowski M, Stefańczyk P, Kosior J, Tułecki Ł, Nowosielecka D. Lead Break during Extraction: Predisposing Factors and Impact on Procedure Complexity and Outcome: Analysis of 3825 Procedures. J Clin Med 2024; 13:2349. [PMID: 38673622 PMCID: PMC11051408 DOI: 10.3390/jcm13082349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Revised: 03/27/2024] [Accepted: 04/08/2024] [Indexed: 04/28/2024] Open
Abstract
Background: Currently, there are no reports describing lead break (LB) during transvenous lead extraction (TLE). Methods: This study conducted a retrospective analysis of 3825 consecutive TLEs using mechanical sheaths. Results: Fracture of the lead, defined as LB, with a long lead fragment (LF) occurred in 2.48%, LB with a short LF in 1.20%, LB with the tip of the lead in 1.78%, and LB with loss of a free-floating LF in 0.57% of cases. In total, extractions with LB occurred in 6.04% of the cases studied. In cases in which the lead remnant comprises more than the tip only, there was a 50.31% chance of removing the lead fragment in its entirety and an 18.41% chance of significantly reducing its length (to less than 4 cm). Risk factors for LB are similar to those for major complications and increased procedure complexity, including long lead dwell time [OR = 1.018], a higher LV ejection fraction, multiple previous CIED-related procedures, and the extraction of passive fixation leads. The LECOM and LED scores also exhibit a high predictive value. All forms of LB were associated with increased procedure complexity and major complications (9.96 vs. 1.53%). There was no incidence of procedure-related death among such patients, and LB did not affect the survival statistics after TLE. Conclusions: LB during TLE occurs in 6.04% of procedures, and this predictable difficulty increases procedure complexity and the risk of major complications. Thus, the possibility of LB should be taken into account when planning the lead extraction strategy and its associated training.
Collapse
Affiliation(s)
- Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin, 20-059 Lublin, Poland;
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-055 Katowice, Poland
| | - Marek Czajkowski
- Department of Cardiac Surgery, Medical University of Lublin, 20-059 Lublin, Poland
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
| | - Jarosław Kosior
- Department of Cardiology, Masovian Specialistic Hospital of Radom, 26-617 Radom, Poland
| | - Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
| |
Collapse
|
18
|
Kutarski A, Jacheć W, Stefańczyk P, Brzozowski W, Głowniak A, Nowosielecka D. Analysis of 1051 ICD Leads Extractions in Search of Factors Affecting Procedure Difficulty and Complications: Number of Coils, Tip Fixation and Position-Does It Matter? J Clin Med 2024; 13:1261. [PMID: 38592112 PMCID: PMC10931966 DOI: 10.3390/jcm13051261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Revised: 02/19/2024] [Accepted: 02/21/2024] [Indexed: 04/10/2024] Open
Abstract
Background: Implantable cardioverter-defibrillator (ICD) leads are considered a risk factor for major complications (MC) during transvenous lead extraction (TLE). Methods: We analyzed 3878 TLE procedures (including 1051 ICD lead extractions). Results: In patients with ICD lead removal, implant duration was almost half as long (69.69 vs. 114.0 months; p < 0.001), procedure complexity (duration of dilatation of all extracted leads, use of more advanced tools or additional venous access) (15.13% vs. 20.78%; p < 0.001) and MC (0.67% vs. 2.62%; p < 0.001) were significantly lower as compared to patients with pacing lead extraction. The procedural success rate was higher in these patients (98.29% vs. 94.04%; p < 0.001). Extraction of two or more ICD leads or additional superior vena cava (SVC) coil significantly prolonged procedure time, increased procedure complexity and use of auxiliary or advanced tools but did not influence the rate of MC. The type of ICD lead fixation and tip position did not affect TLE complexity, complications and clinical success although passive fixation reduces the likelihood of procedural success (OR = 0.297; p = 0.011). Multivariable regression analysis showed that ICD lead implant duration ≥120 months (OR = 2.956; p < 0.001) and the number of coils in targeted ICD lead(s) (OR = 2.123; p = 0.003) but not passive-fixation ICD leads (1.361; p = 0.149) or single coil ICD leads (OR = 1.540; p = 0.177) were predictors of higher procedure complexity, but had no influence on MC or clinical and procedural success. ICD lead implant duration was of crucial importance, similar to the number of leads. Lead dwell time >10 years is associated with a high level of procedure difficulty and complexity but not with MC and procedure-related deaths. Conclusions: The main factors affecting the transvenous removal of ICD leads are implant duration and the number of targeted ICD leads. Dual coil and passive fixation ICD leads are a bit more difficult to extract whereas fixation mechanism and tip position play a much less dominant role.
Collapse
Affiliation(s)
- Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin, 20-059 Lublin, Poland; (A.K.)
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-055 Katowice, Poland;
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland
| | - Wojciech Brzozowski
- Department of Cardiology, Medical University of Lublin, 20-059 Lublin, Poland; (A.K.)
| | - Andrzej Głowniak
- Department of Cardiology, Medical University of Lublin, 20-059 Lublin, Poland; (A.K.)
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland
| |
Collapse
|
19
|
Franczyk B, Rysz J, Olszewski R, Gluba-Sagr A. Do Implantable Cardioverter-Defibrillators Prevent Sudden Cardiac Death in End-Stage Renal Disease Patients on Dialysis? J Clin Med 2024; 13:1176. [PMID: 38398488 PMCID: PMC10889557 DOI: 10.3390/jcm13041176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 01/23/2024] [Accepted: 02/08/2024] [Indexed: 02/25/2024] Open
Abstract
Chronic kidney disease patients appear to be predisposed to heart rhythm disorders, including atrial fibrillation/atrial flutter, ventricular arrhythmias, and supraventricular tachycardias, which increase the risk of sudden cardiac death. The pathophysiological factors underlying arrhythmia and sudden cardiac death in patients with end-stage renal disease are unique and include timing and frequency of dialysis and dialysate composition, vulnerable myocardium, and acute proarrhythmic factors triggering asystole. The high incidence of sudden cardiac deaths suggests that this population could benefit from implantable cardioverter-defibrillator therapy. The introduction of implantable cardioverter-defibrillators significantly decreased the rate of all-cause mortality; however, the benefits of this therapy among patients with chronic kidney disease remain controversial since the studies provide conflicting results. Electrolyte imbalances in haemodialysis patients may result in ineffective shock therapy or the appearance of non-shockable underlying arrhythmic sudden cardiac death. Moreover, the implantation of such devices is associated with a risk of infections and central venous stenosis. Therefore, in the population of patients with heart failure and severe renal impairment, periprocedural risk and life expectancy must be considered when deciding on potential device implantation. Harmonised management of rhythm disorders and renal disease can potentially minimise risks and improve patients' outcomes and prognosis.
Collapse
Affiliation(s)
- Beata Franczyk
- Department of Nephrology, Hypertension and Family Medicine, Medical University of Lodz, 90-419 Lodz, Poland; (B.F.); (J.R.)
| | - Jacek Rysz
- Department of Nephrology, Hypertension and Family Medicine, Medical University of Lodz, 90-419 Lodz, Poland; (B.F.); (J.R.)
| | - Robert Olszewski
- Department of Gerontology, Public Health and Didactics, National Institute of Geriatrics, Rheumatology and Rehabilitation, 02-637 Warsaw, Poland;
| | - Anna Gluba-Sagr
- Department of Nephrology, Hypertension and Family Medicine, Medical University of Lodz, 90-419 Lodz, Poland; (B.F.); (J.R.)
| |
Collapse
|
20
|
Czajkowski M, Polewczyk A, Jacheć W, Kosior J, Nowosielecka D, Tułecki Ł, Stefańczyk P, Kutarski A. Multilevel Venous Obstruction in Patients with Cardiac Implantable Electronic Devices. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:336. [PMID: 38399623 PMCID: PMC10890105 DOI: 10.3390/medicina60020336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Revised: 01/28/2024] [Accepted: 02/12/2024] [Indexed: 02/25/2024]
Abstract
Background and Objectives: The nature of multilevel lead-related venous stenosis/occlusion (MLVSO) and its influence on transvenous lead extraction (TLE) as well as long-term survival remains poorly understood. Materials and Methods: A total of 3002 venograms obtained before a TLE were analyzed to identify the risk factors for MLVSO, as well as the procedure effectiveness and long-term survival. Results: An older patient age at the first system implantation (OR = 1.015; p < 0.001), the number of leads in the heart (OR = 1.556; p < 0.001), the placement of the coronary sinus (CS) lead (OR = 1.270; p = 0.027), leads on both sides of the chest (OR = 7.203; p < 0.001), and a previous device upgrade or downgrade with lead abandonment (OR = 2.298; p < 0.001) were the strongest predictors of MLVSO. Conclusions: The presence of MLVSO predisposes patients with cardiac implantable electronic devices (CIED) to the development of infectious complications. Patients with multiple narrowed veins are likely to undergo longer and more complex procedures with complications, and the rates of clinical and procedural success are lower in this group. Long-term survival after a TLE is similar in patients with MLVSO and those without venous obstruction. MLVSO probably better depicts the severity of global venous obstruction than the degree of vein narrowing at only one point.
Collapse
Affiliation(s)
- Marek Czajkowski
- Department of Cardiac Surgery, Medical University of Lublin, 20-059 Lublin, Poland;
| | - Anna Polewczyk
- Institute of Medical Sciences, Jan Kochanowski University, 25-317 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Center of Cardiology, 25-736 Kielce, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, 41-800 Zabrze, Poland;
| | - Jarosław Kosior
- Department of Cardiology, Masovian Specialist Hospital of Radom, 26-617 Radom, Poland;
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland; (D.N.); (P.S.)
| | - Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland;
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland; (D.N.); (P.S.)
| | - Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin, 20-059 Lublin, Poland;
| |
Collapse
|
21
|
Kutarski A, Jacheć W, Stefańczyk P, Polewczyk A, Kosior J, Nowosielecka D. VDD Lead Extraction-Differences with Other Leads and Practical Tips in Management. J Clin Med 2024; 13:800. [PMID: 38337494 PMCID: PMC10856487 DOI: 10.3390/jcm13030800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 01/24/2024] [Accepted: 01/26/2024] [Indexed: 02/12/2024] Open
Abstract
Background: VDD (atrial sensing, ventricular sensing/pacing) leads are relatively rarely implanted; therefore, experience in their extraction is very limited. We aimed to investigate whether VDD lead removal may be a risk factor for the increased complexity of transvenous lead extraction (TLE) or major complications. Methods: We retrospectively analyzed 3808 TLE procedures (including 103 patients with VDD leads). Results: If TLE included VDD lead removal, procedure duration (lead dilation time) was prolonged, complicated extractions were slightly more common, and more advanced tools were required. This is partly due to longer implant duration (in patients with VDD systems-135.2 months; systems without VDD leads-109.3 months; p < 0.001), more frequent presence of abandoned leads (all systems containing VDD leads-22.33% and all systems without VDD leads-10.77%), and partly to the younger age of patients with VDD leads (51.74 vs. 57.72 years; p < 0.001, in the remaining patients) at the time of system implantation. VDD lead extraction does not increase the risk of major complications (1.94 vs. 2.34%; p = 0.905). Conclusions: The extraction of VDD leads may be considered a risk factor for increased procedure complexity, but not for major complications. However, this is not a direct result of VDD lead extraction but specific characteristics of the patients with VDD leads. Operator skill and team experience combined with special custom maneuvers can enable favorable results to be achieved despite the specific design of VDD leads, even with older VDD lead models.
Collapse
Affiliation(s)
- Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin, 20-059 Lublin, Poland;
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-055 Katowice, Poland
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
| | - Anna Polewczyk
- Department of Medicine and Health Sciences, The John Kochanowski University, 25-369 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Center of Cardiology, 25-736 Kielce, Poland
| | - Jarosław Kosior
- Department of Cardiology, Masovian Specialistic Hospital of Radom, 26-617 Radom, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
| |
Collapse
|
22
|
Jacheć W, Nowosielecka D, Ziaja B, Polewczyk A, Kutarski A. LECOM (Lead Extraction COMplexity): A New Scoring System for Predicting a Difficult Procedure. J Clin Med 2023; 12:7568. [PMID: 38137637 PMCID: PMC10743865 DOI: 10.3390/jcm12247568] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 12/01/2023] [Accepted: 12/05/2023] [Indexed: 12/24/2023] Open
Abstract
(1) Background: Transvenous lead extraction (TLE) can become far more complex when unanticipated difficulties arise. The aim was to develop a simple scoring system that allows for the prediction of the difficulty and complexity of this significant procedure. (2) Methods: Based on analysis of 3741 TLE procedures with and without complicating factors (extended fluoroscopy time, need for second-line instruments, and advanced techniques and instruments), a five-point Complex Indicator of Difficulty of (TLE) Procedure (CID-TLEP) scale was developed. Two or more points on the CID-TLEP scale indicate a higher level of procedure complexity. (3) Results: Patient age below 51 years at first CIED implantation, number of abandoned leads, number of previous procedures, passive fixation and multiple leads to be extracted, and a ratio of dwell time of oldest lead to patient age during TLE of >0.13 are significant predictors of higher levels of lead extraction complexity. The ROC analysis demonstrates that a point total (being the sum of the odds ratios of the above variables) of >9.697 indicates a 21.83% higher probability of complex TLE (sensitivity 74.08%, specificity 74.46%). Finally, a logistic function was calculated, and we constructed a simple equation for lead extraction complexity that can predict the probability of a difficult procedure. The risk of complex extraction (as a percentage) is calculated as [1/(1 + 55.34 · 0.754X)] · 100 (p < 0.001). (4) Conclusion: The LECOM score can effectively predict the risk of a difficult transvenous lead extraction procedure, and predicting the probability of a more complex procedure may help clinicians in planning lead removal and improving patient management.
Collapse
Affiliation(s)
- Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-055 Katowice, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Bettina Ziaja
- Department of Cardiology, Specialist Hospital, 41-800 Zabrze, Poland
| | - Anna Polewczyk
- Department of Medicine and Health Sciences, The Jan Kochanowski University, 25-369 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Center of Cardiology, 25-736 Kielce, Poland
| | - Andrzej Kutarski
- Department of Cardiology, Medical University, 20-059 Lublin, Poland
| |
Collapse
|
23
|
Kwon S, Lee E, Choi EK, Lee SR, Oh S, Choi YS. Long-term outcomes of abandoned leads of cardiac implantable electronic devices. Heart Rhythm 2023; 20:1639-1646. [PMID: 37543304 DOI: 10.1016/j.hrthm.2023.07.068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 07/25/2023] [Accepted: 07/27/2023] [Indexed: 08/07/2023]
Abstract
BACKGROUND Evidence of the long-term outcomes of abandoned leads (ALs) in patients with cardiac implantable electronic devices (CIEDs) is scarce. OBJECTIVE This study aimed to investigate the long-term outcomes of ALs. METHODS This retrospective cohort study reviewed a single-center CIED registry of 2962 procedures performed from 1984-2018 and identified 130 patients with AL (AL group). We matched 2 controls without AL (by age, sex, device type, and device revision/removal date) to each patient with AL (n = 260) and compared CIED-related infection, venous thrombosis/stenosis, and all-cause mortality between groups using a Cox proportional hazard model analysis. RESULTS For a mean follow-up period of 11.2 ± 8.2 years, 14 (3.6%), 7 (1.8%), and 143 (36.7%) patients had a CIED-related infection, venous thrombosis/stenosis, or experienced all-cause mortality, respectively. The AL group had more comorbidities than the control group. Lead malfunction was the most common cause of abandonment (64.6%). After adjustment for covariates, no significant intergroup differences were noted in the risks of infection, venous thrombosis/stenosis, or all-cause mortality (adjusted hazard ratio [aHR] 2.52; 95% confidence interval [CI] 0.77-8.25; aHR 1.18; 95% CI 0.25-5.64; aHR 1.26; 95% CI 0.89-1.80, respectively). Patients with multiple ALs had increased risks of infection and all-cause mortality vs controls (aHR 8.61; 95% CI 2.13-34.84; aHR 2.42; 95% CI 1.17-5.00, respectively). CONCLUSION Patients with a single AL showed similar risks of CIED-related infections, venous thrombosis/stenosis, and all-cause mortality as those without ALs, whereas those with multiple ALs showed increased risks of infection and all-cause mortality.
Collapse
Affiliation(s)
- Soonil Kwon
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Euijae Lee
- Department of Cardiovascular Medicine, Bucheon Sejong Hospital, Bucheon, Republic of Korea
| | - Eue-Keun Choi
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea; Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea.
| | - So-Ryoung Lee
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Seil Oh
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea; Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Yun-Shik Choi
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea; Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
24
|
Erdem A, Torun A. Misplacement of pacemaker leads: How to avoid and how to approach? Pacing Clin Electrophysiol 2023; 46:1662-1664. [PMID: 37910444 DOI: 10.1111/pace.14865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 10/14/2023] [Accepted: 10/22/2023] [Indexed: 11/03/2023]
Abstract
The use of cardiac implantable electronic devices has increased in recent years due to factors such as a growing population, increased life expectancy, and improved access to healthcare services. In parallel with this trend, complications related to pacemakers have also increased. One of the most important and preventable complications among these is lead misplacement. Misplacement of a permanent pacemaker lead in the LV can lead to a variety of complications, including damage to the heart muscle, arrhythmias, blood clotes and cerebrovascular events. It is recommended to use the fluoroscopic 40° LAO view during implantation. That view clearly defines the interatrial and interventricular septum. Right bundle branch block pattern on ECG is an important clue to suspected misplaced lead. In addition to the postero-anterior (PA) projection of x-ray, the latero-lateral (LL) projection provides a clearer view of lead malposition. In the LL view, the tip of an incorrectly positioned LV lead is characteristically directed toward the spine. If diagnosed soon after implantation, percutaneous lead extraction can reduce the risk of future thromboembolic events without the need for lifelong anticoagulation. It should be noted that in cases with a lead in the LV for a long time, lead removal is not the primary recommendation. Patient-based approach should be fundamental.
Collapse
Affiliation(s)
- Almina Erdem
- Department of Cardiology, Health Sciences University, Sultan II. Abdülhamid Han Training and Research Hospital, Istanbul, Turkey
| | - Akin Torun
- Department of Cardiology, Health Sciences University, Sultan II. Abdülhamid Han Training and Research Hospital, Istanbul, Turkey
| |
Collapse
|
25
|
Isawa T, Honda T, Yamaya K, Toyoda S, Taguri M. Associated factors and outcomes of crossover from a laser sheath to a bidirectional rotational mechanical sheath during transvenous lead extraction. J Arrhythm 2023; 39:947-955. [PMID: 38045454 PMCID: PMC10692839 DOI: 10.1002/joa3.12929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Revised: 08/21/2023] [Accepted: 09/14/2023] [Indexed: 12/05/2023] Open
Abstract
Background During transvenous lead extraction (TLE), a GlideLight laser sheath (Philips) cannot always be advanced over the lead, and crossover to the Evolution system (i.e., an Evolution RL sheath or Evolution Shortie RL sheath [Cook Medical]) is required. We aimed to determine the associated factors and outcomes of such device crossover. Methods This observational study included 112 patients who underwent TLE. The patients were divided into crossover and non-crossover groups. Outcomes and associated factors of crossover were evaluated. Results Overall, 57 (50.9%) patients required crossover to the Evolution system (crossover group), whereas 55 (49.1%) patients did not require crossover (non-crossover group). Clinical success rate was similar between the two groups (98.3% vs. 100%; p = 1.00). No major intraprocedural complications related to powered sheaths occurred. Multivariate logistic regression analysis results showed that dwell time of the oldest extracted lead (per year) (odds ratio [OR]: 1.18, 95% confidence interval [CI]: 1.02-1.36; p = .026), number of leads extracted per procedure (OR: 7.23, 95% CI: 1.74-29.99; p = .007), and use of a femoral approach (OR: 21.09, 95% CI: 2.33-190.67; p = .007) were associated factors of crossover. The cutoff for crossover was 7.7 years from the implant (sensitivity 90.5%, specificity 64.9%, area under the curve 0.80). Conclusions Both groups showed a high rate of clinical success. Switching to the Evolution system may facilitate a safe and effective TLE when a laser sheath does not advance despite laser activation.
Collapse
Affiliation(s)
- Tsuyoshi Isawa
- Department of CardiologySendai Kousei HospitalSendaiJapan
| | - Taku Honda
- Department of CardiologySendai Kousei HospitalSendaiJapan
| | - Kazuhiro Yamaya
- Department of Cardiovascular SurgerySendai Kousei HospitalSendaiJapan
| | - Shigeru Toyoda
- Department of Cardiovascular MedicineDokkyo Medical UniversityMibuJapan
| | - Masataka Taguri
- Department of Health Data ScienceTokyo Medical UniversityTokyoJapan
| |
Collapse
|
26
|
Kellersmann R, Manke C. Aktueller Stand der endovaskulären Behandlung von Shuntdysfunktionen. GEFÄSSCHIRURGIE 2023; 28:564-573. [DOI: 10.1007/s00772-023-01061-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 11/06/2023] [Indexed: 01/07/2025]
|
27
|
Gabriels JK, Schaller RD, Koss E, Rutkin BJ, Carrillo RG, Epstein LM. Lead management in patients undergoing percutaneous tricuspid valve replacement or repair: a 'heart team' approach. Europace 2023; 25:euad300. [PMID: 37772978 PMCID: PMC10629975 DOI: 10.1093/europace/euad300] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 09/11/2023] [Accepted: 09/24/2023] [Indexed: 09/30/2023] Open
Abstract
Clinically significant tricuspid regurgitation (TR) has historically been managed with either medical therapy or surgical interventions. More recently, percutaneous trans-catheter tricuspid valve (TV) replacement and tricuspid trans-catheter edge-to-edge repair have emerged as alternative treatment modalities. Patients with cardiac implantable electronic devices (CIEDs) have an increased incidence of TR. Severe TR in this population can occur for multiple reasons but most often results from the interactions between the CIED lead and the TV apparatus. Management decisions in patients with CIED leads and clinically significant TR, who are undergoing evaluation for a percutaneous TV intervention, need careful consideration as a trans-venous lead extraction (TLE) may both worsen and improve TR severity. Furthermore, given the potential risks of 'jailing' a CIED lead at the time of a percutaneous TV intervention (lead fracture and risk of subsequent infections), consideration should be given to performing a TLE prior to a percutaneous TV intervention. The purpose of this 'state-of-the-art' review is to provide an overview of the causes of TR in patients with CIEDs, discuss the available therapeutic options for patients with TR and CIED leads, and advocate for including a lead management specialist as a member of the 'heart team' when making treatment decisions in patients TR and CIED leads.
Collapse
Affiliation(s)
- James K Gabriels
- Department of Cardiology, Zucker School of Medicine at Hofstra/Northwell, North Shore University Hospital, 300 Community Drive, Manhasset, NY, USA
| | - Robert D Schaller
- Electrophysiology Section, Division of Cardiovascular Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA, USA
| | - Elana Koss
- Department of Cardiovascular and Thoracic Surgery, Zucker School of Medicine at Hofstra/Northwell, North Shore University Hospital, Manhasset, NY, USA
| | - Bruce J Rutkin
- Department of Cardiovascular and Thoracic Surgery, Zucker School of Medicine at Hofstra/Northwell, North Shore University Hospital, Manhasset, NY, USA
| | | | - Laurence M Epstein
- Department of Cardiology, Zucker School of Medicine at Hofstra/Northwell, North Shore University Hospital, 300 Community Drive, Manhasset, NY, USA
| |
Collapse
|
28
|
Khurana S, Das S, Frishman WH, Aronow WS, Frenkel D. Lead Extraction-Indications, Procedure, and Future Directions. Cardiol Rev 2023:00045415-990000000-00152. [PMID: 37729602 DOI: 10.1097/crd.0000000000000610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
Cardiac implantable electronic device (CIED) implantation has steadily increased in the United States owing to increased life expectancy, better access to health care, and the adoption of updated guidelines. Transvenous lead extraction (TLE) is an invasive technique for the removal of CIED devices, and the most common indications include device infections, lead failures, and venous occlusion. Although in-hospital and procedure-related deaths for patients undergoing TLE are low, the long-term mortality remains high with 10-year survival reported close to 50% after TLE. This is likely demonstrative of the increased burden of comorbidities with aging. There are guidelines provided by various professional societies, including the Heart Rhythm Society, regarding indications for lead extraction and management of these patients. In this paper, we will review the indications for CIED extraction, procedural considerations, and management of these patients based upon the latest guidelines.
Collapse
Affiliation(s)
- Sumit Khurana
- From the Department of Internal medicine, MedStar Union Memorial hospital, Baltimore, MD
| | - Subrat Das
- Department of Cardiology, New York Medical College, Westchester Medical Center, Valhalla, NY
| | - William H Frishman
- Department of Medicine, Westchester Medical Center and New York Medical College, NY
| | - Wilbert S Aronow
- Department of Cardiology, New York Medical College, Westchester Medical Center, Valhalla, NY
| | - Daniel Frenkel
- Department of Cardiology, New York Medical College, Westchester Medical Center, Valhalla, NY
| |
Collapse
|
29
|
Whearty L, Lever N, Martin A. Transvenous Lead Extraction: Outcomes From a Single Centre Providing a National Service for New Zealand. Heart Lung Circ 2023; 32:1115-1121. [PMID: 37271619 DOI: 10.1016/j.hlc.2023.05.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 04/27/2023] [Accepted: 05/14/2023] [Indexed: 06/06/2023]
Abstract
BACKGROUND With increasing demand for cardiac implantable electronic devices there is a parallel increase in the need for transvenous lead extraction (TLE). Due to its small population, all TLE procedures in New Zealand are currently performed in a single centre, Auckland City Hospital. We analysed the clinical characteristics and outcomes of those undergoing TLE since this service was established. METHODS We performed a retrospective, single-centre cohort study of all TLE procedures between October 2015 and December 2021. Definitions from the European Lead Extraction Controlled study, Heart Rhythm Society, European Heart Rhythm Association consensus documents were used. RESULTS A total of 247 patients had 480 leads extracted, averaging 40 TLE procedures annually. Patients had a median lead dwell time of 6 (interquartile range [IQR] 3-11) years, 60 (13%) of leads had been in-situ >15 years, median age 61 (IQR 48-70) years, 73 (30%) female, 28 (11%) Māori, 23 (9%) Pasifika. Lead dysfunction (115 patients, 47%) and infection (90 patients, 37%) were the most common indications for TLE. Complete clinical and radiological success was achieved for 96% and 95%, respectively. Procedure-related complications occurred in 16 (7%) patients. Major intra-procedure complications occurred in 5 patients (2%), including 2 (1%) deaths. Death within one year of TLE occurred in 13 (26%) with systemic infection, 5 (3%) with local infection, and 5 (3%) with non-infection indications for TLE, p <0.01. CONCLUSIONS TLE is associated with high radiographic and clinical success, low complication, and low mortality rate. At our single centre providing a national service, TLE outcomes are comparable with those achieved internationally.
Collapse
Affiliation(s)
- Lauren Whearty
- Te Kupenga Hauora Māori, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Nigel Lever
- Te Kupenga Hauora Māori, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand; Green Lane Cardiovascular Services, Auckland City Hospital, Te Whatu Ora | Te Toka Tumai-Health New Zealand, Auckland, New Zealand
| | - Andrew Martin
- Green Lane Cardiovascular Services, Auckland City Hospital, Te Whatu Ora | Te Toka Tumai-Health New Zealand, Auckland, New Zealand.
| |
Collapse
|
30
|
Frei C, Hofer D, Jan S, Grebmer C, Breitenstein A. Single center experience with the novel rotating dilator sheath TightRail TM Sub-C in transvenous lead extraction. J Cardiovasc Electrophysiol 2023; 34:1738-1743. [PMID: 37343057 DOI: 10.1111/jce.15970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 05/06/2023] [Accepted: 06/05/2023] [Indexed: 06/23/2023]
Abstract
INTRODUCTION Transvenous lead extraction has become a frequent procedure in the context of device lead management and various tools are available. The aim of this study was to investigate the efficacy and safety of the novel short rotating dilator sheath TightRailTM Sub-C (Sub-C) in transvenous lead extraction. METHODS For this retrospective single-center analysis, we included consecutive patients undergoing transvenous lead extraction using the Sub-C from January 2018 until February 2020 at the University Heart Center Zurich. RESULTS A total of 87 leads were extracted within 45 patients using the Sub-C extraction sheath. The mean dwell time of the leads was 112 ± 9.1 months. Complete procedural success was achieved in 95.6% (43/45) and clinical procedural success in 97.8% (44/45). Two major complications (4.4%, 2/45) occurred, but neither was directly related to the Sub-C. CONCLUSION This retrospective single-center analysis suggests that transvenous lead extraction with a routine use of the TightRailTM Sub-C extraction sheath is a safe strategy resulting in high success rates that may offer useful theoretical benefits. Future studies are needed to evaluate the incremental benefit of a routine use of short extraction sheaths including the Sub-C during TLE procedures.
Collapse
Affiliation(s)
- Celine Frei
- Electrophysiology, Department of Cardiology, University Hospital Zurich, University Heart Center, Zurich, Switzerland
| | - Daniel Hofer
- Electrophysiology, Department of Cardiology, University Hospital Zurich, University Heart Center, Zurich, Switzerland
| | - Steffel Jan
- Electrophysiology, Department of Cardiology, University Hospital Zurich, University Heart Center, Zurich, Switzerland
| | - Christian Grebmer
- Department of Cardiology, Cantonal Hospital Lucerne, Lucerne, Switzerland
| | - Alexander Breitenstein
- Electrophysiology, Department of Cardiology, University Hospital Zurich, University Heart Center, Zurich, Switzerland
| |
Collapse
|
31
|
Halboni A, Dawdy J, Mishra T, Dayco J, Kottam A. 18F-FDG PET/CT assisted exclusion of cardiac device-related infective endocarditis. J Nucl Cardiol 2023; 30:1702-1705. [PMID: 35618990 DOI: 10.1007/s12350-022-03008-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Accepted: 04/26/2022] [Indexed: 11/30/2022]
Affiliation(s)
- Adnan Halboni
- Department of Internal Medicine, Detroit Medical Center/Wayne State University, Detroit, MI, USA
| | - John Dawdy
- Division of Cardiology, Department of Internal Medicine, Detroit Medical Center/Wayne State University, Detroit, MI, USA.
| | - Tushar Mishra
- Division of Cardiology, Department of Internal Medicine, Detroit Medical Center/Wayne State University, Detroit, MI, USA
| | - John Dayco
- Department of Internal Medicine, Detroit Medical Center/Wayne State University, Detroit, MI, USA
| | - Anupama Kottam
- Division of Cardiology, Department of Internal Medicine, Detroit Medical Center/Wayne State University, Detroit, MI, USA
| |
Collapse
|
32
|
Bock M, O’Connor M, Chouchane A, Schmidt P, Schaarschmidt C, Knoll K, Bahlke F, Englert F, Storz T, Kottmaier M, Trenkwalder T, Reents T, Bourier F, Telishevska M, Lengauer S, Hessling G, Deisenhofer I, Kolb C, Lennerz C. Cardiologist-Directed Sedation Management in Patients Undergoing Transvenous Lead Extraction: A Single-Centre Retrospective Analysis. J Clin Med 2023; 12:4900. [PMID: 37568301 PMCID: PMC10420171 DOI: 10.3390/jcm12154900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 07/07/2023] [Accepted: 07/18/2023] [Indexed: 08/13/2023] Open
Abstract
BACKGROUND The demand for transvenous lead extraction (TLE) has increased. In line with this, the safety of such procedures has also increased. Traditionally, TLE is performed under resource-intensive general anaesthesia. This study aims to evaluate the safety and outcomes of Cardiologist-lead deep sedation for TLE. METHODS We retrospectively analysed 328 TLE procedures performed under deep sedation from 2016 to 2019. TLE procedures were performed by experienced electrophysiologists. Sedation was administered by a specifically trained cardiologist (bolus midazolam/fentanyl and propofol infusion). Procedural sedation data including blood pressure, medication administration and sedation time were collected. Complications related to sedation and the operative component of the procedure were analysed retrospectively. RESULTS The sedation-associated complication rate during TLE was 22.0%. The most common complication (75% of complications) was hypotension requiring noradrenaline, followed by bradycardia requiring atropine (13% of complications). Additionally, the unplanned presence of an anaesthesiologist was needed in one case (0.3%). Deep sedation was achieved with midazolam (mean dose 42.9 ± 26.5 µg/kg), fentanyl (mean dose 0.4 ± 0.6 µg/kg) and propofol (mean dose 3.5 ± 1.2 mg/kg/h). There was no difference in medication dosage between those with a sedation-associated complication and those without. Sedation-associated complications appeared significantly more in patients with reduced LVEF (p = 0.01), renal impairment (p = 0.01) and a higher American Society of Anaesthesiologists (ASA) class (p = 0.01). CONCLUSION Deep sedation for TLE can be safely performed by a specifically trained cardiologist, with a transition to general anaesthesia required in only 0.3% of cases. We continue to recommend the on-call availability of an anaesthesiologist and cardiac surgeon in case of major complications.
Collapse
Affiliation(s)
- Matthias Bock
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
- DZHK (German Centre for Cardiovascular Research, Partner Site Munich, Heart Alliance), 80336 Munich, Germany
| | - Matthew O’Connor
- Auckland City Hospital, Department of Cardiology, Auckland 1023, New Zealand
| | - Amir Chouchane
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Philip Schmidt
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Claudia Schaarschmidt
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Katharina Knoll
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
- DZHK (German Centre for Cardiovascular Research, Partner Site Munich, Heart Alliance), 80336 Munich, Germany
| | - Fabian Bahlke
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Florian Englert
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Theresa Storz
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Marc Kottmaier
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Teresa Trenkwalder
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Tilko Reents
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Felix Bourier
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Marta Telishevska
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Sarah Lengauer
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Gabriele Hessling
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Isabel Deisenhofer
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Christof Kolb
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
| | - Carsten Lennerz
- German Heart Centre Munich, Department of Electrophysiology, Technical University of Munich, 80636 Munich, Germany (C.K.)
- DZHK (German Centre for Cardiovascular Research, Partner Site Munich, Heart Alliance), 80336 Munich, Germany
| |
Collapse
|
33
|
Okada A, Higuchi S, Shoda M, Tabata H, Kataoka S, Shoin W, Kobayashi H, Okano T, Yoshie K, Kato K, Saigusa T, Ebisawa S, Motoki H, Kuwahara K. Utility of a multipurpose catheter for transvenous extraction of old broken leads: A novel technique for fragile leads. Heart Rhythm 2023; 20:976-981. [PMID: 37001747 DOI: 10.1016/j.hrthm.2023.03.209] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 03/24/2023] [Accepted: 03/24/2023] [Indexed: 04/24/2023]
Abstract
BACKGROUND Transvenous lead extraction has been possible since the 1980s. However, complications during lead extraction, such as the distal end fragment of the lead remaining in the myocardium or venous system and injury to the veins or heart, have been reported. OBJECTIVE The purpose of this study was to examine our method for complete removal of a separated lead, as extraction of long-term implanted devices is difficult using standard methods and may require additional procedures. The removal of leads with inner conductor coil and lead tip separated from outer insulation, conductor coil, and proximal ring electrode using a multipurpose catheter is reported. METHODS In total, 345 consecutive patients who underwent transvenous lead extraction (TLE) from April 2014 to March 2021 were retrospectively analyzed. Lead characteristics, device type, and indications for extraction were further analyzed in 20 patients who developed separation of the proximal ring electrode and outer conductor coil from the inner conductor and distal tip at the time of extraction. RESULTS Extractions were performed using an excimer laser sheath laser and a Byrd polypropylene telescoping sheath (n = 15); laser, Byrd polypropylene telescoping sheath, and Evolution RL (n = 2); laser and Evolution RL (n = 3); Byrd polypropylene telescoping sheath and Evolution RL (n = 1); Byrd polypropylene telescoping sheath only (n = 4); and Evolution RL only (n = 2). Twenty-seven leads implanted for more than 10 years had lead separation. A multipurpose catheter was used to protect the fragile leads from further damage. All leads were completely extracted. CONCLUSION All distal tip-to-proximal ring electrode separated leads were successfully removed using laser and other sheaths with the assistance of a multipurpose catheter, without any part of the leads remaining in the heart.
Collapse
Affiliation(s)
- Ayako Okada
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Satoshi Higuchi
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Morio Shoda
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan; Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan.
| | - Hiroaki Tabata
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Shohei Kataoka
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Wataru Shoin
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Hideki Kobayashi
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Takahiro Okano
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Koji Yoshie
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Ken Kato
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan; Department of Cardiology, Tama Metropolitan Medical Center, Tokyo, Japan
| | - Tatsuya Saigusa
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Soichiro Ebisawa
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Hirohiko Motoki
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Koichiro Kuwahara
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| |
Collapse
|
34
|
Milman A, Wieder-Finesod A, Zahavi G, Meitus A, Kariv S, Shafir Y, Beinart R, Rahav G, Nof E. Complicated Pocket Infection in Patients Undergoing Lead Extraction: Characteristics and Outcomes. J Clin Med 2023; 12:4397. [PMID: 37445433 DOI: 10.3390/jcm12134397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 06/18/2023] [Accepted: 06/26/2023] [Indexed: 07/15/2023] Open
Abstract
Cardiac implantable electronic device (CIED) infection can present with pocket or systemic manifestations, both necessitating complete device removal and pathogen-directed antimicrobial therapy. Here, we aim to characterize those presenting with both pocket and systemic infection. A retrospective analysis of CIED extraction procedures included 300 patients divided into isolated pocket (n = 104, 34.7%), complicated pocket (n = 54, 18%), and systemic infection (n = 142, 47.3%) groups. The systemic and complicated pocket groups frequently presented with leukocytosis and fever > 37.8, as opposed to the isolated pocket group. Staphylococcus aureus was the most common pathogen in the systemic and complicated pocket groups (43.7% and 31.5%, respectively), while Coagulase-negative staphylococci (CONS) predominated (31.7%) in the isolated pocket group (10.6%, p < 0.001). No differences were observed in procedural success or complications rates. Kaplan-Meier survival analysis found that at three years of follow-up, the rate of all-cause mortality was significantly higher among patients with systemic infection compared to both pocket groups (p < 0.001), with the curves diverging at thirty days. In this study, we characterize a new entity of complicated pocket infection. Despite the systemic pattern of infection, their prognosis is similar to isolated pocket infection. We suggest that this special category be presented separately in future publications of CIED infections.
Collapse
Affiliation(s)
- Anat Milman
- Leviev Heart Institute, The Chaim Sheba Medical Center, Tel Hashomer, Ramat Gan 5262000, Israel
- Sackler School of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Anat Wieder-Finesod
- Sackler School of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
- The Infectious Diseases Unit, Sheba Medical Center, Tel-Hashomer, Ramat Gan 5262000, Israel
| | - Guy Zahavi
- Sackler School of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
- Department of Anesthesiology and Intensive Care, The Chaim Sheba Medical Center, Tel Hashomer, Ramat Gan 5262000, Israel
| | - Amit Meitus
- Sackler School of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Saar Kariv
- Sackler School of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Yuval Shafir
- Leviev Heart Institute, The Chaim Sheba Medical Center, Tel Hashomer, Ramat Gan 5262000, Israel
- Sackler School of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Roy Beinart
- Leviev Heart Institute, The Chaim Sheba Medical Center, Tel Hashomer, Ramat Gan 5262000, Israel
- Sackler School of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Galia Rahav
- Sackler School of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
- The Infectious Diseases Unit, Sheba Medical Center, Tel-Hashomer, Ramat Gan 5262000, Israel
| | - Eyal Nof
- Leviev Heart Institute, The Chaim Sheba Medical Center, Tel Hashomer, Ramat Gan 5262000, Israel
- Sackler School of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| |
Collapse
|
35
|
Giudice M, Catuzzo B, Berlier N, Lau EW, Bonnemeier H, Assadian O, Baldauf B, Borov S, Scacciatella P. Use of Taurolidine in a Patient With a Cardiac Implantable Electronic Device Protrusion. JACC Case Rep 2023; 14:101835. [PMID: 37152697 PMCID: PMC10157148 DOI: 10.1016/j.jaccas.2023.101835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Accepted: 03/01/2023] [Indexed: 05/09/2023]
Abstract
We report the successful salvage of cardiac implantable electronic device pulse generator protrusion sealed by the surrounding skin in a frail patient presenting 5 months after the last surgical revision. (Level of Difficulty: Advanced.).
Collapse
Affiliation(s)
- Marcello Giudice
- Department for Cardiology and Electrophysiology, U. Parini Hospital, Aosta, Italy
| | - Bruna Catuzzo
- Department for Cardiology and Electrophysiology, U. Parini Hospital, Aosta, Italy
| | - Nicola Berlier
- Department for Cardiology and Electrophysiology, U. Parini Hospital, Aosta, Italy
| | | | - Hendrik Bonnemeier
- Helios Klinikum Cuxhaven, Cuxhaven, Germany
- Helios Klinikum Wesermarsch, Nordenham, Germany
- Christian-Albrechts University, Kiel, Germany
| | - Ojan Assadian
- Landesklinikum Wiener Neustadt, Wiener Neustadt, Austria
| | | | - Stefan Borov
- Christian-Albrechts University, Kiel, Germany
- Lakumed Kliniken, Landshut, Germany
| | - Paolo Scacciatella
- Department for Cardiology and Electrophysiology, U. Parini Hospital, Aosta, Italy
| |
Collapse
|
36
|
Domain G, Strubé C, Jacques F, Marzouk M, Dumont É, Villeneuve J, Plourde B, Albert G, Sarrazin JF, Steinberg C, Philippon F. Superior vena cava tear during transvenous lead extraction: Medical management in hemodynamically stable patients. Pacing Clin Electrophysiol 2023. [PMID: 37196145 DOI: 10.1111/pace.14718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 03/31/2023] [Accepted: 05/02/2023] [Indexed: 05/19/2023]
Abstract
INTRODUCTION Superior vena cava (SVC) tear is the most lethal complication during transvenous lead extraction (TLE) with a mortality rate as high as 50%. Treatment involves aggressive attempts to maintain cardiac output and immediate sternotomy to localize and repair the vascular tear. Occlusion balloons have been developed to provisionally occlude the lacerated SVC and to provide hemodynamic stability allowing time for surgery. In case of mediastinal hematoma without hemodynamic instability, the strategy remains unclear. METHODS AND RESULTS We describe two cases of SVC tear during TLE. The first case was a 60-year-old man who presented with a right ventricular single-chamber defibrillator lead fracture and innominate vein stenosis. The RV lead was removed using a laser sheath causing a mediastinal hematoma with no active bleeding during surgical exploration few hours later. The second case was a 28-year-old man that presented with a right atrial (RA) lead fracture and RV lead insulation failure in a dual-chamber defibrillator (ICD). CONCLUSION Both the RA and RV leads were removed with mechanical sheaths, and a mediastinal hematoma was medically managed.
Collapse
Affiliation(s)
- Guillaume Domain
- Electrophysiology Division, Institut Uuniversitaire de Cardiologie et de Pneumologie de Québec, Laval University, Quebec, Canada
| | - Camille Strubé
- Electrophysiology Division, Institut Uuniversitaire de Cardiologie et de Pneumologie de Québec, Laval University, Quebec, Canada
| | - Frédéric Jacques
- Cardiac Surgery Division, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Laval University, Quebec, Canada
| | - Mohamed Marzouk
- Cardiac Surgery Division, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Laval University, Quebec, Canada
| | - Éric Dumont
- Cardiac Surgery Division, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Laval University, Quebec, Canada
| | - Jacques Villeneuve
- Anesthesiology Department, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Laval University, Quebec, Canada
| | - Benoît Plourde
- Electrophysiology Division, Institut Uuniversitaire de Cardiologie et de Pneumologie de Québec, Laval University, Quebec, Canada
| | - Gabriella Albert
- Radiology Department, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Laval University, Quebec, Canada
| | - Jean-François Sarrazin
- Electrophysiology Division, Institut Uuniversitaire de Cardiologie et de Pneumologie de Québec, Laval University, Quebec, Canada
| | - Christian Steinberg
- Electrophysiology Division, Institut Uuniversitaire de Cardiologie et de Pneumologie de Québec, Laval University, Quebec, Canada
| | - François Philippon
- Electrophysiology Division, Institut Uuniversitaire de Cardiologie et de Pneumologie de Québec, Laval University, Quebec, Canada
| |
Collapse
|
37
|
Hussein AA, Wazni OM, Wilkoff BL. Cardiac Implantable Electronic Devices and Infective Endocarditis: A Call to Arms…. J Am Coll Cardiol 2023; 81:1726-1728. [PMID: 37100489 DOI: 10.1016/j.jacc.2023.02.043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 02/27/2023] [Indexed: 04/28/2023]
Affiliation(s)
- Ayman A Hussein
- Section of Cardiac Pacing and Electrophysiology, Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio, USA.
| | - Oussama M Wazni
- Section of Cardiac Pacing and Electrophysiology, Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Bruce L Wilkoff
- Section of Cardiac Pacing and Electrophysiology, Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio, USA
| |
Collapse
|
38
|
Arabia G, Mitacchione G, Cersosimo A, Calvi E, Salghetti F, Bontempi L, Giacopelli D, Cerini M, Curnis A. Long-term outcomes following transvenous lead extraction: Data from a tertiary referral center. Int J Cardiol 2023; 378:32-38. [PMID: 36841289 DOI: 10.1016/j.ijcard.2023.02.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 02/16/2023] [Accepted: 02/22/2023] [Indexed: 02/27/2023]
Abstract
BACKGROUND Transvenous lead extraction (TLE) has shown a safe and efficacy profile in the intraoperative and short-term setting; however, data on long-term outcomes are limited. OBJECTIVE The purpose of this study was to assess long-term outcomes and prognostic factors in patients who underwent TLE. METHODS Consecutive patients with cardiac implantable electronic device (CIED) who underwent TLE between 2014 and 2016 were retrospectively studied. The primary outcome was the composite endpoint of death and repeated TLE stratified by infective/non-infective indication. Individual components of the primary outcome were also evaluated. RESULTS One hundred ninety-one patients were included in the analysis, 50% extracted for CIED-related infection. Complete procedural success was achieved in 189 patients (99%) with no major acute complications. After a median of 6.5 years, infection indication was associated with significantly lower event-free survival (67% vs. 83% non-infection group, adjusted hazard ratio [aHR] 1.97, 95% confidence interval [CI] 1.02-3.81, p = 0.04). All-cause mortality rate was higher in the TLE infection group (30% vs. 10%, p < 0.01). The rate of repeated TLE did not differ between groups (4% vs. 7%, p = 0.62). Among patients who had TLE for infection, the presence of vegetation (aHR 2.56; 95%CI 1.17-5.63, p = 0.02) and positive blood cultures (aHR 2.64; 95%CI 1.04-6.70, p = 0.04) were independently associated with the primary outcome. CONCLUSION Patients who underwent TLE for CIED-related infection exhibit a high mortality risk during long-term follow-up. Vegetation and positive blood cultures in patients with CIED-related infection are associated with a worse prognosis regardless of successful and uncomplicated TLE.
Collapse
Affiliation(s)
- Gianmarco Arabia
- Cardiology Department, Spedali Civili Hospital, University of Brescia, Italy.
| | | | - Angelica Cersosimo
- Cardiology Department, Spedali Civili Hospital, University of Brescia, Italy
| | - Emiliano Calvi
- Cardiology Department, Spedali Civili Hospital, University of Brescia, Italy
| | - Francesca Salghetti
- Cardiology Department, Spedali Civili Hospital, University of Brescia, Italy
| | - Luca Bontempi
- Cardiology Department, Spedali Civili Hospital, University of Brescia, Italy
| | - Daniele Giacopelli
- Clinical Unit, Biotronik Italia, Cologno Monzese (MI), Italy; Department of Cardiac, Thoracic, Vascular Sciences & Public Health, University of Padova, Italy
| | - Manuel Cerini
- Cardiology Department, Spedali Civili Hospital, University of Brescia, Italy
| | - Antonio Curnis
- Cardiology Department, Spedali Civili Hospital, University of Brescia, Italy
| |
Collapse
|
39
|
Kutarski A, Jacheć W, Polewczyk A, Nowosielecka D. Incomplete Lead Removal During the Extraction Procedure: Predisposing Factors and Impact on Long-Term Survival in Infectious and Non-Infectious Cases: Analysis of 3741 Procedures. J Clin Med 2023; 12:jcm12082837. [PMID: 37109174 PMCID: PMC10144379 DOI: 10.3390/jcm12082837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 03/27/2023] [Accepted: 04/11/2023] [Indexed: 04/29/2023] Open
Abstract
BACKGROUND The long-term significance of lead remnants (LR) following transvenous lead extraction (TLE) remains disputable, especially in infectious patients. METHODS Retrospective analysis of 3741 TLEs focused on the relationship between LR and procedure complexity, complications and long-term survival. RESULTS The study group consisted of 156 individuals with LR (4.17%), and the control group consisted of 3585 patients with completely removed lead(s). In a multivariable model, a younger patient age at CIED implantation, more CIED procedures and procedure complexity were independent risk factors for retention of non-removable LR. Although patients with LR showed better survival outcomes following TLE (log rank p = 0.041 for non-infectious group and p = 0.017 for infectious group), multivariable Cox regression analysis did not confirm the prognostic significance of LR either in non-infectious [HR = 0.777; p = 0.262], infectious [HR = 0.983; p = 0.934] or the entire group of patients [HR = 0.858; p = 0.321]. CONCLUSIONS 1. Non-removable LRs are encountered in 4.17% of patients. 2. CIED infection has no influence on retention of LRs, but younger patient age, multiple CIED-related procedures and higher levels of procedure complexity are independent risk factors for the presence of LR. 3. Better survival outcomes following TLE in patients with LRs are not the effects of their presence but younger patient and better health status.
Collapse
Affiliation(s)
- Andrzej Kutarski
- Department of Cardiology, Medical University, 20-059 Lublin, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, 41-800 Zabrze, Poland
| | - Anna Polewczyk
- Department of Medicine and Health Sciences, The Jan Kochanowski University, 25-369 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Center of Cardiology, 25-736 Kielce, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| |
Collapse
|
40
|
Kutarski A, Jacheć W, Nowosielecka D, Polewczyk A. Unexpected Procedure Difficulties Increasing the Complexity of Transvenous Lead Extraction: The Single Centre Experience with 3721 Procedures. J Clin Med 2023; 12:jcm12082811. [PMID: 37109149 PMCID: PMC10143656 DOI: 10.3390/jcm12082811] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 04/04/2023] [Accepted: 04/06/2023] [Indexed: 04/29/2023] Open
Abstract
BACKGROUND Transvenous lead extraction (TLE) should be completed, even when facing difficulties which have yet to be described. The aim was to explore unexpected TLE obstacles (the circumstances of the occurrence and influence on TLE outcome). METHODS The retrospective analysis of a single centre database containing 3721 TLEs. RESULTS Unexpected procedure difficulties (UPDs) occurred in 18.43% of cases (singles in 12.20% of cases and multiples in 6.26% of cases). These included blockages in the lead venous approach in3.28% of cases, functional lead dislodgement in 0.91% of cases, and loss of broken lead fragment in 0.60% of cases. All of them, including implant vein-in 7.98% of cases, lead fracture during extraction-in 3.84% of cases, and lead-to-lead adherence-in 6.59% of cases, Byrd dilator collapse-in 3.41% of cases, including the use of an alternative prolonged the procedure but had no influence on long-term mortality. Most of the occurrences were associated with lead dwell time, younger patient age, lead burden, and poorer procedure effectiveness and complications (common cause). However, some of the problems seemed to be related to cardiac implantable electronic devices (CIED) implantation and the subsequent lead management strategy. A more complete list of all tips and tricks is still required. CONCLUSIONS (1) The complexity of the lead extraction procedure combines both prolonged procedure duration and the occurrence of lesser-known UPDs. (2) UPDs are present in nearly one fifth of the TLE procedures, and can occur simultaneously. (3) UPDs, which usually force the extractor to expand the range of techniques and tools, should become part of the training in transvenous lead extraction.
Collapse
Affiliation(s)
- Andrzej Kutarski
- Department of Cardiology, Medical University, 20-059 Lublin, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, 41-800 Zabrze, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Anna Polewczyk
- Department of Physiology, Pathophysiology and Clinical Immunology, Institute of Medical Sciences, Jan Kochanowski University, 25-369 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Center of Cardiology, 25-736 Kielce, Poland
| |
Collapse
|
41
|
Lakkireddy DR, Segar DS, Sood A, Wu M, Rao A, Sohail MR, Pokorney SD, Blomström-Lundqvist C, Piccini JP, Granger CB. Early Lead Extraction for Infected Implanted Cardiac Electronic Devices: JACC Review Topic of the Week. J Am Coll Cardiol 2023; 81:1283-1295. [PMID: 36990548 DOI: 10.1016/j.jacc.2023.01.038] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 01/04/2023] [Accepted: 01/18/2023] [Indexed: 03/31/2023]
Abstract
Infection remains a serious complication associated with the cardiac implantable electronic devices (CIEDs), leading to substantial clinical and economic burden globally. This review assesses the burden of cardiac implantable electronic device infection (CIED-I), evidence for treatment recommendations, barriers to early diagnosis and appropriate therapy, and potential solutions. Multiple clinical practice guidelines recommended complete system and lead removal for CIED-I when appropriate. CIED extraction for infection has been consistently reported with high success, low complication, and very low mortality rates. Complete and early extraction was associated with significantly better clinical and economic outcome compared with no or late extraction. However, significant gaps in knowledge and poor recommendation compliance have been reported. Barriers to optimal management may include diagnostic delay, knowledge gaps, and limited access to expertise. A multipronged approach, including education of all stakeholders, a CIED-I alert system, and improving access to experts, could help bring paradigm shift in the treatment of this serious condition.
Collapse
Affiliation(s)
| | - Douglas S Segar
- Ascension Heart Center of Indiana, Indianapolis, Indiana, USA
| | - Ami Sood
- Philips Image Guided Therapy Corporation, Colorado Springs, Colorado, USA
| | | | - Archana Rao
- Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, United Kingdom
| | - M Rizwan Sohail
- Section of Infectious Diseases, Department of Medicine, Baylor College of Medicine, Houston, Texas, USA
| | - Sean D Pokorney
- Duke University Medical Center and Duke Clinical Research Institute, Duke University, Durham, North Carolina, USA
| | - Carina Blomström-Lundqvist
- Department of Cardiology, School of Medical Sciences, Faculty of Medicine and Health, Örebro University, Örebro, Sweden; Department of Medical Science, Uppsala University, Uppsala, Sweden
| | - Jonathan P Piccini
- Duke University Medical Center and Duke Clinical Research Institute, Duke University, Durham, North Carolina, USA
| | - Christopher B Granger
- Duke University Medical Center and Duke Clinical Research Institute, Duke University, Durham, North Carolina, USA
| |
Collapse
|
42
|
Hofer D, Kuster N, Bebié MC, Sasse T, Steffel J, Breitenstein A. Success and Complication Rates of Transvenous Lead Extraction in a Developing High-Volume Extraction Center: The Zurich Experience. J Clin Med 2023; 12:jcm12062260. [PMID: 36983262 PMCID: PMC10051593 DOI: 10.3390/jcm12062260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Revised: 03/06/2023] [Accepted: 03/08/2023] [Indexed: 03/17/2023] Open
Abstract
Introduction: Transvenous lead extractions are increasingly performed for malfunction or infection of cardiac implantable electronic devices, but they harvest a potential for complications and suboptimal success. Apart from multicenter registries and reports from highly experienced single centers, the outcome in individual newly developing high-volume centers starting a lead extraction program is less well established. We aimed to evaluate the clinical and radiological success and complication rate at our center, having started a lead extraction program less than a decade ago. Methods: We retrospectively analyzed patients who underwent transvenous lead extraction at the University Hospital Zurich from 2013 to 2021 regarding success as well as complications and compared our results to previously reported outcome rates. Results: A total of 346 patients underwent 350 transvenous lead extractions from January 2013 to December 2021. Combined radiological success was achieved in 97.7% and clinical success in 96.0% of interventions. Procedure-related major complications occurred in 13 patients (3.7%). Death within 30 days after transvenous lead extractions occurred in 13 patients (3.7%), with a procedure-related mortality of 1.4% (five patients). Summary: Transvenous lead extractions in newly developing high-volume centers can be performed with high clinical and radiological success rates, but procedure-related major complications may affect a relevant number of patients. Compared to large single or multicenter registries of experienced centers, the success rate may be lower and the complication rate higher in centers newly starting with lead extraction, which may have important implications for patient selection, procedural planning, proctoring, and safety measures.
Collapse
|
43
|
Villegas EG, Juárez Del Río JI, Carmona JCR, Valdíris UR, Peinado ÁA, Peinado RP. Efficacy and safety of the extraction of cardiostimulation leads using a mechanical dissection tool. A single center experience. Pacing Clin Electrophysiol 2023; 46:217-225. [PMID: 36401870 DOI: 10.1111/pace.14625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 10/28/2022] [Accepted: 11/15/2022] [Indexed: 11/21/2022]
Abstract
BACKGROUND The percutaneous extraction of endovascular cardiostimulation and defibrillation leads is the most frequent technique nowadays. The tools used today must guarantee the success of the procedure, with the minimum of complications. Our objective was to analyze the safety and efficacy of lead extraction using the Evolution mechanical dissection tool (Cook Medical, USA). METHODS A retrospective study was carried out in a total of 826 consecutive patients from October 2009 to December 2018 who underwent the procedure with the Evolution mechanical dissection tool. Preoperative study included complete blood tests, echocardiogram, and chest X-ray. The procedures were performed in the operating room, under general anesthesia and echocardiographic control. RESULTS A total of 1227 leads were extracted with a mean chronicity of 10.3 ± 5.1 years. Clinical success (CS) rate was 99.7%. A total of 16 (1.9%) complications occurred, 2 (0.24%) were major complications and 14 (1.7%) were minor complications. There was no operative mortality. There was no statistically significant relationship between implant chamber and complete efficacy. The complete extraction was achieved in all left ventricular leads, in 762 of 774 (98.45%) of right ventricular lead removal, and in 330 of 334 (98.8%) of right atrial leads (p = .31). CONCLUSION In our experience, percutaneous extraction of intravenous leads via the use of the Evolution tool (Cook Medical, USA), is a very effective and safe technique that offers low morbidity and mortality.
Collapse
|
44
|
Roberts PR, Clémenty N, Mondoly P, Winter S, Bordachar P, Sharman D, Jung W, Eschalier R, Theis C, Defaye P, Anderson C, Pol A, Butler K, Garweg C. A leadless pacemaker in the real-world setting: Patient profile and performance over time. J Arrhythm 2023; 39:1-9. [PMID: 36733321 PMCID: PMC9885317 DOI: 10.1002/joa3.12811] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 12/08/2022] [Accepted: 12/24/2022] [Indexed: 01/10/2023] Open
Abstract
Background While prior Micra trials demonstrated a high implant success rate and favorable safety and efficacy results, changes in implant populations and safety over time is not well studied. The objective of this analysis was to report the performance of Micra in European and Middle Eastern patients and compare to the Micra Investigational Device Exemption (IDE) and Micra Post Approval Registry (PAR) studies. Methods The prospective, single-arm Micra Acute Performance European and Middle Eastern (MAP EMEA) registry was designed to further study the performance of Micra in patients from EMEA. The primary endpoint was to characterize acute (30-day) major complications. Electrical performance was analyzed. The major complication rate through 12 months was compared with the IDE and PAR studies. Results The MAP EMEA cohort (n = 928 patients) had an implant success rate of 99.9% and were followed for an average of 9.7 ± 6.5 months. Compared to prior studies, MAP EMEA patients were more likely to have undergone dialysis and have a condition which precluded the use of a transvenous pacemaker (p < .001). Within 30 days of implantation, the MAP EMEA cohort had a major complication rate of 2.59%. Mean pacing thresholds were low and stable through 12 months (0.61 ± 0.40 V at 0.24 ms at implant and 12 months). Through 12 months post-implantation, the major complication rate for MAP EMEA was not significantly different from IDE (p = .56) or PAR (p = .79). Conclusion Despite patient differences over time, the Micra leadless pacemaker was implanted with a high success rate and low complication rate, in-line with prior reports.
Collapse
Affiliation(s)
- Paul R. Roberts
- University Hospital Southampton NHS Foundation TrustSouthamptonUK
| | | | - Pierre Mondoly
- Centre Hospitalier Universitaire de ToulouseToulouseFrance
| | | | | | | | - Werner Jung
- Schwarzwald‐Baar Klinikum Villingen‐SchwenningenVillingen‐SchwenningenGermany
| | - Romain Eschalier
- Université Clermont Auvergne and Cardiology Department, CHU Clermont‐Ferrand, CNRSSIGMA Clermont, Institut PascalClermont‐FerrandFrance
| | | | - Pascal Defaye
- Centre Hospitalier Universitaire de GrenobleLa TroncheFrance
| | | | - Aimée Pol
- Medtronic Bakken Research CenterMaastrichtThe Netherlands
| | | | | |
Collapse
|
45
|
Miguelena Hycka J, López Menéndez J, Martín García M, Muñoz Pérez R, Castro Pinto M, Torres Terreros CB, García Chumbiray PF, Rodriguez-Roda J. Electrodos no funcionantes ¿Extracción o abandono? CIRUGIA CARDIOVASCULAR 2023. [DOI: 10.1016/j.circv.2022.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023] Open
|
46
|
Mahajan P, Aedma SK, Ally S, Garg A. AngioVac system guided removal of vegetations from pacemaker lead-related infective endocarditis. BMJ Case Rep 2023; 16:e251097. [PMID: 36669789 PMCID: PMC9872456 DOI: 10.1136/bcr-2022-251097] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/04/2023] [Indexed: 01/22/2023] Open
Abstract
The AngioVac aspiration system is a catheter-based technique that has been used for removal of unwanted intravascular material in growing numbers of institutions around the world since 2013. It provides an alternative and a less invasive approach for the treatment of venous thromboembolism and intrinsic or cardiac implantable electronic devices (CIED)-related infective endocarditis. This system uses venous cannulas and extracorporeal filtering mechanisms to effectively remove thrombi or vegetations resulting in less invasion and minimal blood loss. We present a case of a woman in her mid-50s who underwent successful AngioVac-guided removal of lead vegetations followed by percutaneous CIED removal.
Collapse
Affiliation(s)
- Pranav Mahajan
- Internal Medicine, Carle Foundation Hospital, Urbana, Illinois, USA
- Cardiology, Lehigh Valley Health Network, Allentown, Pennsylvania, USA
| | - Surya Kiran Aedma
- Internal Medicine, Carle Foundation Hospital, Urbana, Illinois, USA
- Cardiology, University of California, Riverside, Riverside, California, USA
| | - Saeed Ally
- Cardiovascular & Thoracic Surgery, Heart & Vascular, Carle Foundation Hospital, Urbana, Illinois, USA
| | - Anuj Garg
- Electrophysiology, Cardiology, Heart & Vascular, Carle Foundation Hospital, Urbana, Illinois, USA
| |
Collapse
|
47
|
Patel H, Harrell S, Hreibe H, Sharkawi M, AlJaroudi W. A Rare Case of Persistent Bacteremia: Leadless Micra Pacemaker Endocarditis. Case Rep Cardiol 2023; 2023:8326020. [PMID: 36713823 PMCID: PMC9876663 DOI: 10.1155/2023/8326020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 12/23/2022] [Accepted: 12/29/2022] [Indexed: 01/19/2023] Open
Abstract
Leadless pacing systems have revolutionized the field of electrophysiology given its low complication rates and almost non-existent rate of infections compared with traditional pacemakers. These devices boast resistance to infections given its unique features; however, as described in this report, device-related infection from these leadless devices is still possible. In patients with leadless pacing system that is persistently bacteremic in the future, evaluation of the device with transesophageal echocardiogram or intracardiac echocardiography should be performed, and if vegetation is noted on the device, device extraction should highly be considered, along with empiric intravenous antibiotics. Lastly, new leadless device should not be re-implanted within 2 weeks of the removal of the infected device to prevent seeding of the new device.
Collapse
Affiliation(s)
- Himax Patel
- Augusta University Medical Center, 1120 15th Street, Augusta, GA 30912, USA
| | - Sean Harrell
- Augusta University Medical Center, 1120 15th Street, Augusta, GA 30912, USA
| | - Haitham Hreibe
- Augusta University Medical Center, 1120 15th Street, Augusta, GA 30912, USA
| | - Musa Sharkawi
- Augusta University Medical Center, 1120 15th Street, Augusta, GA 30912, USA
| | - Wael AlJaroudi
- Augusta University Medical Center, 1120 15th Street, Augusta, GA 30912, USA
| |
Collapse
|
48
|
Huang X, Zhou H, Li XM, Li XL. Case report: Left ventricular perforation caused by right ventricular pacemaker lead. Front Cardiovasc Med 2023; 9:1089694. [PMID: 36712247 PMCID: PMC9877449 DOI: 10.3389/fcvm.2022.1089694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 12/19/2022] [Indexed: 01/15/2023] Open
Abstract
Background Perforation of the interventricular septum and left ventricular (LV) free wall by a right ventricular (RV) lead is an extremely rare and potentially life-threatening complication. In this case report, we discussed the diagnosis and management of a very unusual complication of pacemaker (PM) implantation, i.e., LV perforation brought on by an RV pacing lead. Case summary A 92-year-old man was admitted to Xiangyang No.1 People's Hospital due to a complete atrioventricular block. We performed a dual-chamber PM implantation; however, on the second postoperative day (POD), pacemaker failure occurred. Thoracic computed tomography (CT) scan showed that RV lead had pierced the interventricular septum and LV free wall. A transvenous lead extraction of the penetrating lead was performed uneventfully, and RV lead was refixed at the lower RV septum on the 5th POD. Discussion Identification of high-risk patients is mandatory to prevent this serious complication, and transvenous lead extraction with cardiac surgery backup may be an option.
Collapse
|
49
|
Abstract
The use of positron emission tomography imaging with 18F-fluorodeoxyglucose in the diagnostic workup of patients with suspected prosthetic valve endocarditis and cardiac device infection (implantable electronic device and left ventricular assist device) is gaining momentum in clinical practice. However, in the absence of prospective randomized trials, guideline recommendations about 18F-fluorodeoxyglucose positron emission tomography in this setting are currently largely based on expert opinion. Measurement of aortic valve microcalcification occurring as a healing response to valvular inflammation using 18F-sodium fluoride positron emission tomography represents another promising clinical approach, which is associated with both the risk of native valve stenosis progression and bioprosthetic valve degeneration in research trials. In this review, we consider the role of molecular imaging in cardiac valvular diseases, including aortic stenosis and valvular endocarditis, as well as cardiac device infections.
Collapse
Affiliation(s)
- Jason M Tarkin
- Heart and Lung Research Institute, University of Cambridge, UK (J.M.T.)
| | - Wengen Chen
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, MD (W.C., V.D.)
| | - Marc R Dweck
- British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, UK (M.R.D.)
| | - Vasken Dilsizian
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, MD (W.C., V.D.)
| |
Collapse
|
50
|
Shaikh A, Albalas A, Desiraju B, Dwyer A, Haddad N, Almehmi A. The role of stents in hemodialysis vascular access. J Vasc Access 2023; 24:107-116. [PMID: 33993804 PMCID: PMC10896277 DOI: 10.1177/11297298211015069] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Vascular access is the Achilles' heel of dialysis therapy among patient with end stage kidney disease. The development of neointimal hyperplasia and subsequent stenosis is common in vascular access and is associated with significant morbidity. Percutaneous transluminal angioplasty using balloon inflation was the standard therapy of these lesions. However, the balloon-based approaches were associated with poor vascular access patency rate necessitating new inventions. It is within this context that different types of stents were developed in order to improve the overall dialysis vascular access functionality. In this article, we review the available literature regarding the use of stents in treating dialysis vascular access stenotic lesions. Further, we review the major clinical trials of stent use in different anatomic locations and in different clinical scenarios.
Collapse
Affiliation(s)
- Aisha Shaikh
- Department of Medicine, James J. Peters VA Medical Center, Bronx, NY, USA
| | - Alian Albalas
- Department of Biology, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Brinda Desiraju
- Department of Medicine, SUNY Downstate School of Medicine, Brooklyn, NY, USA
| | - Amy Dwyer
- Department of Medicine, University of Louisville, Louisville, KY, USA
| | - Nabil Haddad
- Department of Medicine, The Ohio State University Medical Center, Columbus, OH, USA
| | - Ammar Almehmi
- Department of Medicine and Radiology, University of Alabama at Birmingham, Birmingham, AL, USA
| |
Collapse
|