1
|
Ramanathan S, Lau WJ, Goh PS, Gopinath SCB, Rawindran H, Omar MF, Ismail AF, Breadmore MC, See HH. Tailoring molecularly imprinted polymer on titanium-multiwalled carbon nanotube functionalized gold electrode for enhanced chlorophyll determination in microalgae health assessment. Mikrochim Acta 2024; 191:586. [PMID: 39251454 DOI: 10.1007/s00604-024-06662-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2024] [Accepted: 08/27/2024] [Indexed: 09/11/2024]
Abstract
A unique method for determining chlorophyll content in microalgae is devised employing a gold interdigitated electrode (G-IDE) with a 10-µm gap, augmented by a nano-molecularly imprinted polymer (nano-MIP) and a titanium dioxide/multiwalled carbon nanotube (TiO2/MWCNT) nanocomposite. The nano-MIP, produced using chlorophyll template voids, successfully trapped chlorophyll, while the TiO2/MWCNT nanocomposite, synthesized by the sol-gel technique, exhibited a consistent distribution and anatase crystalline structure. The rebinding of procured chlorophyll powder, which was used as a template for nano-MIP synthesis, was identified with a high determination coefficient (R2 = 0.9857). By combining the TiO2/MWCNT nanocomposite with nano-MIP, the G-IDE sensing method achieved a slightly better R2 value of 0.9892 for detecting chlorophyll in microalgae. The presented G-IDE sensor showed a significant threefold enhancement in chlorophyll detection compared with commercially available chlorophyll powder. It had a detection limit of 0.917 mL (v/v) and a linear range that spanned from 10-6 to 1 mL. The effectiveness of the sensor in detecting chlorophyll in microalgae was confirmed through validation of its repeatability and reusability.
Collapse
Affiliation(s)
- Santheraleka Ramanathan
- Department of Chemical and Petroleum Engineering, Faculty of Engineering, Technology and Built Environment, UCSI University, Kuala Lumpur, Malaysia.
| | - Woei Jye Lau
- Faculty of Chemical and Energy Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| | - Pei Sean Goh
- Faculty of Chemical and Energy Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| | - Subash C B Gopinath
- Center for Global Health Research, Saveetha Medical College & Hospital, Saveetha Institute of Medical and Technical Sciences (SIMATS), Thandalam, Chennai-602 105, Tamil Nadu, India
- Faculty of Chemical Engineering & Technology, Universiti Malaysia Perlis (UniMAP), 02600, Arau, Perlis, Malaysia
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, 01000, Malaysia
- Department of Technical Sciences, Western Caspian University, Baku, AZ, 1075, Azerbaijan
| | - Hemamalini Rawindran
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| | - Muhammad Firdaus Omar
- Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| | - Ahmad Fauzi Ismail
- Faculty of Chemical and Energy Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| | - Michael C Breadmore
- Australian Centre for Research On Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, TAS, 7001, Australia
| | - Hong Heng See
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| |
Collapse
|
2
|
Nigam R, Kar KK. Effect of Mixed Morphology (Simple Cubic, Face-Centered Cubic, and Body-Centered Cubic)-Based Electrodes on the Electric Double Layer Capacitance of Supercapacitors. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:14266-14280. [PMID: 38941262 DOI: 10.1021/acs.langmuir.4c00664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/30/2024]
Abstract
Supercapacitors store energy due to the formation of an electric double layer (EDL) at the interface of the electrodes and electrolyte. The present article deals with the finite element study of equilibrium electric double layer capacitance (EDLC) in the mixed morphology electrodes comprising all three fundamental crystal structures, simple cubic (SC), body-centered cubic (BCC), and face-centered cubic morphologies (FCC). Mesoporous-activated carbon forms the electrode in the supercapacitor with (C2H5)4NBF4/propylene carbonate organic electrolyte. Electrochemical interference is clearly demonstrated in the supercapacitors with the formation of the potential bands, as in the case of interference theory due to the increasing packing factor. The effects of electrode thickness varying from a wide range of 50 nm to 0.04 mm on specific EDLC have been discussed in detail. The interfacial geometry of the unit cell in contact with the electrolyte is the most important parameter determining the properties of the EDL. The critical thickness of the electrodes is 1.71 μm in all the morphologies. Polarization increases the interfacial potential and leads to EDL formation. The Stern layer specific capacitance is 167.6 μF cm-2 in all the morphologies. The maximum capacitance is in the decreasing order of interfacial geometry, as FCC > BCC > SC, dependent on the packing factor. The minimum transmittance in all the morphologies is 98.35%, with the constant figure of merit at higher electrode thickness having applications in the chip interconnects. The transient analysis shows that the interfacial current decreases with increasing polarization in the EDL. The capacitance also decreases with the increase of the scan rate.
Collapse
Affiliation(s)
- Ravi Nigam
- Advanced Nanoengineering Materials Laboratory, Materials Science Programme, Indian Institute of Technology Kanpur, Kanpur 208016, India
| | - Kamal K Kar
- Advanced Nanoengineering Materials Laboratory, Materials Science Programme, Indian Institute of Technology Kanpur, Kanpur 208016, India
- Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur 208016, India
| |
Collapse
|
3
|
Korek EM, Teotia R, Herbig D, Brederlow R. Electrochemical Impedance Spectroscopy for Ion Sensors with Interdigitated Electrodes: Capacitance Calculations, Equivalent Circuit Models and Design Optimizations. BIOSENSORS 2024; 14:241. [PMID: 38785715 PMCID: PMC11117819 DOI: 10.3390/bios14050241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 05/05/2024] [Accepted: 05/08/2024] [Indexed: 05/25/2024]
Abstract
Electrochemical impedance spectroscopy (EIS) is becoming more and more relevant for the characterization of biosensors employing interdigitated electrodes. We compare four different sensor topologies for an exemplary use case of ion sensing to extract recommendations for the design optimizations of impedimetric biosensors. Therefore, we first extract how sensor design parameters affect the sensor capacitance using analytical calculations and finite element (FEM) simulations. Moreover, we develop equivalent circuit models for our sensor topologies and validate them using FEM simulations. As a result, the impedimetric sensor response is better understood, and sensitive and selective frequency ranges can be determined for a given sensor topology. From this, we extract design optimizations for different sensing principles.
Collapse
Affiliation(s)
- Eva-Maria Korek
- School of Computation, Information and Technology, Technical University of Munich, 80333 Munich, Germany (D.H.); (R.B.)
| | | | | | | |
Collapse
|
4
|
Rahman SFA, Arshad MKM, Gopinath SCB, Fathil MFM, Sarry F, Ibau C, Elmazria O, Hage-Ali S. Interdigitated impedimetric-based Maackia amurensis lectin biosensor for prostate cancer biomarker. Mikrochim Acta 2024; 191:118. [PMID: 38296851 DOI: 10.1007/s00604-024-06189-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 01/01/2024] [Indexed: 02/02/2024]
Abstract
Highly specific detection of tumor-associated biomarkers remains a challenge in the diagnosis of prostate cancer. In this research, Maackia amurensis (MAA) was used as a recognition element in the functionalization of an electrochemical impedance-spectroscopy biosensor without a label to identify cancer-associated aberrant glycosylation prostate-specific antigen (PSA). The lectin was immobilized on gold-interdigitated microelectrodes. Furthermore, the biosensor's impedance response was used to assess the establishment of a complex binding between MAA and PSA-containing glycans. With a small sample volume, the functionalized interdigitated impedimetric-based (IIB) biosensor exhibited high sensitivity, rapid response, and repeatability. PSA glycoprotein detection was performed by measuring electron transfer resistance values within a concentration range 0.01-100 ng/mL, with a detection limit of 3.574 pg/mL. In this study, the ability of MAA to preferentially recognize α2,3-linked sialic acid in serum PSA was proven, suggesting a potential platform for the development of lectin-based, miniaturized, and cost effective IIB biosensors for future disease detection.
Collapse
Affiliation(s)
- Siti Fatimah Abd Rahman
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), 01000, Kangar, Perlis, Malaysia
- School of Electrical and Electronic Engineering, Engineering Campus, Universiti Sains Malaysia (USM), 14300, Nibong Tebal, Pulau Pinang, Malaysia
| | - Mohd Khairuddin Md Arshad
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), 01000, Kangar, Perlis, Malaysia.
- Faculty of Electronic Engineering and Technology, Universiti Malaysia Perlis (UniMAP), 02600, Arau, Perlis, Malaysia.
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), 01000, Kangar, Perlis, Malaysia
- Faculty of Chemical Engineering & Technology, Universiti Malaysia Perlis (UniMAP), 02600, Arau, Perlis, Malaysia
- Centre of Excellence for Micro System Technology (MiCTEC), Universiti Malaysia Perlis (UniMAP), Pauh Campus, 02600, Arau, Perlis, Malaysia
| | | | - Frédéric Sarry
- Université de Lorraine, CNRS, IJL, F-54000, Nancy, France
| | - Conlathan Ibau
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), 01000, Kangar, Perlis, Malaysia
| | - Omar Elmazria
- Université de Lorraine, CNRS, IJL, F-54000, Nancy, France
| | - Sami Hage-Ali
- Université de Lorraine, CNRS, IJL, F-54000, Nancy, France
| |
Collapse
|
5
|
Sitkov N, Ryabko A, Moshnikov V, Aleshin A, Kaplun D, Zimina T. Hybrid Impedimetric Biosensors for Express Protein Markers Detection. MICROMACHINES 2024; 15:181. [PMID: 38398911 PMCID: PMC10890403 DOI: 10.3390/mi15020181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 01/22/2024] [Accepted: 01/23/2024] [Indexed: 02/25/2024]
Abstract
Impedimetric biosensors represent a powerful and promising tool for studying and monitoring biological processes associated with proteins and can contribute to the development of new approaches in the diagnosis and treatment of diseases. The basic principles, analytical methods, and applications of hybrid impedimetric biosensors for express protein detection in biological fluids are described. The advantages of this type of biosensors, such as simplicity and speed of operation, sensitivity and selectivity of analysis, cost-effectiveness, and an ability to be integrated into hybrid microfluidic systems, are demonstrated. Current challenges and development prospects in this area are analyzed. They include (a) the selection of materials for electrodes and formation of nanostructures on their surface; (b) the development of efficient methods for biorecognition elements' deposition on the electrodes' surface, providing the specificity and sensitivity of biosensing; (c) the reducing of nonspecific binding and interference, which could affect specificity; (d) adapting biosensors to real samples and conditions of operation; (e) expanding the range of detected proteins; and, finally, (f) the development of biosensor integration into large microanalytical system technologies. This review could be useful for researchers working in the field of impedimetric biosensors for protein detection, as well as for those interested in the application of this type of biosensor in biomedical diagnostics.
Collapse
Affiliation(s)
- Nikita Sitkov
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
- Engineering Centre for Microtechnology and Diagnostics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| | - Andrey Ryabko
- Laboratory of Nonequilibrium Processes in Semiconductors, Ioffe Institute, 26 Politekhnicheskaya, 194021 Saint Petersburg, Russia;
| | - Vyacheslav Moshnikov
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
| | - Andrey Aleshin
- Laboratory of Nonequilibrium Processes in Semiconductors, Ioffe Institute, 26 Politekhnicheskaya, 194021 Saint Petersburg, Russia;
| | - Dmitry Kaplun
- Artificial Intelligence Research Institute, China University of Mining and Technology, 1 Daxue Road, Xuzhou 221116, China;
- Department of Automation and Control Processes, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| | - Tatiana Zimina
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
- Engineering Centre for Microtechnology and Diagnostics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| |
Collapse
|
6
|
Compton RG, Sokolov SV. Electrochemistry needs electrochemists: “goodbye to rotating discs”. J Solid State Electrochem 2023. [DOI: 10.1007/s10008-023-05443-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/28/2023]
Abstract
AbstractThe essential need for expert, fully trained electrochemists in the successful application of the subject is illustrated with several examples including the use of rotating electrodes and impedance spectroscopy where the use of the techniques in “black box” mode non-experts is likely to lead to disappointment or embarrassment.
Collapse
|
7
|
Nigam R, Kar KK. Simulation Study of Electric Double-Layer Capacitance of Ordered Carbon Electrodes. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:12235-12247. [PMID: 36164778 DOI: 10.1021/acs.langmuir.2c01865] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Supercapacitors are electrochemical energy storage devices having high capacitance, high power density, long cycle life, low cost, easy maintenance, and negligible environmental pollution. The formation of an electric double layer at the electrode-electrolyte interface is mostly responsible for supercapacitors' energy storage. The simulation study of equilibrium electric double-layer capacitance (EDLC) in 3D arranged mesoporous carbon electrodes with a simple cubic morphology and interdigitated electrodes has been done. Continuum theory has been utilized to study the underlying processes involved in EDLC. Interfacial polarization and ion crowding depend on the electrode's critical thickness. Porosity increases the capacitance due to the increase in the electrode surface area. The diffuse-layer specific capacitance of ordered mesoporous carbon electrodes in a (C2H5)4NBF4/propylene carbonate organic electrolyte is in the range of 3.2-13.3 μF cm-2, varying according to the electrode thickness. The Stern-layer specific capacitance is 167.6 μF cm-2, and total equilibrium EDLC is in the range of 3.1-12.3 μF cm-2. The effect of the electric field at the electrode-electrolyte interface on reducing electrolyte permittivity has also been discussed. The EDLC of carbonized interdigitated electrodes is analyzed in a 6 M KOH electrolyte. The diffuse-layer specific capacitance ranges from 118.7 to 352.0 μF cm-2 depending on the width of the interdigitated electrodes. The Stern-layer specific capacitance is 91.2 μF cm-2, and the total EDLC value is 51.6-72.4 μF cm-2. The modeling and simulation approach can be applied to different mesoporous electrodes by varying the supercapacitor component's parameters and geometry.
Collapse
Affiliation(s)
- Ravi Nigam
- Advanced Nanoengineering Materials Laboratory, Materials Science Programme, Indian Institute of Technology, Kanpur 208016, India
| | - Kamal K Kar
- Advanced Nanoengineering Materials Laboratory, Materials Science Programme, Indian Institute of Technology, Kanpur 208016, India
- Advanced Nanoengineering Materials Laboratory, Department of Mechanical Engineering, Indian Institute of Technology, Kanpur 208016, India
| |
Collapse
|
8
|
Nanodiamond conjugated SARS-CoV-2 spike protein: electrochemical impedance immunosensing on a gold microelectrode. Mikrochim Acta 2022; 189:226. [PMID: 35590000 PMCID: PMC9119799 DOI: 10.1007/s00604-022-05320-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Accepted: 04/25/2022] [Indexed: 11/04/2022]
Abstract
A promising immunosensing strategy in diagnosing SARS-CoV-2 is proposed using a 10-µm gap-sized gold interdigitated electrode (AuIDE) to target the surface spike protein (SP). The microelectrode surface was modified by (3-glycidyloxypropyl) trimethoxysilane to enforce the epoxy matrix, which facilitates the immobilization of the anti-SP antibody. The immunosensing performance was evaluated by integrating a nanosized (~ 10 nm) diamond-complexed SP as a target. The proposed immunoassay was quantitatively evaluated through electrochemical impedance spectroscopy (EIS) with the swept frequency from 0.1 to 1 MHz using a 100 mVRMS AC voltage supply. The immunoassay performed without diamond integration showed low sensitivity, with the lowest SP concentration measured at 1 pM at a determination coefficient of R2 = 0.9681. In contrast, the nanodiamond-conjugated SP on the immunosensor showed excellent sensitivity with a determination coefficient of R2 = 0.986. SP detection with a nanodiamond-conjugated target on AuIDE reached the low limit of detection at 189 fM in a linear detection range from 250 to 8000 fM. The specificity of the developed immunosensor was evaluated by interacting influenza-hemagglutinin and SARS-CoV-2-nucleocapsid protein with anti-SP. In addition, the authentic interaction of SP and anti-SP was validated by enzyme-linked immunosorbent assay.
Collapse
|
9
|
Ramanathan S, Gopinath SCB, Ismail ZH, Md Arshad MK, Poopalan P. Aptasensing nucleocapsid protein on nanodiamond assembled gold interdigitated electrodes for impedimetric SARS-CoV-2 infectious disease assessment. Biosens Bioelectron 2022; 197:113735. [PMID: 34736114 PMCID: PMC8550887 DOI: 10.1016/j.bios.2021.113735] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Accepted: 10/25/2021] [Indexed: 12/11/2022]
Abstract
In an aim of developing portable biosensor for SARS-CoV-2 pandemic, which facilitates the point-of-care aptasensing, a strategy using 10 μm gap-sized gold interdigitated electrode (AuIDE) is presented. The silane-modified AuIDE surface was deposited with ∼20 nm diamond and enhanced the detection of SARS-CoV-2 nucleocapsid protein (NCP). The characteristics of chemically modified diamond were evidenced by structural analyses, revealing the cubic crystalline nature at (220) and (111) planes as observed by XRD. XPS analysis denotes a strong interaction of carbon element, composed ∼95% as seen in EDS analysis. The C-C, CC, CO, CN functional groups were well-refuted from XPS spectra of carbon and oxygen elements in diamond. The interrelation between elements through FTIR analysis indicates major intrinsic bondings at 2687-2031 cm-1. The aptasensing was evaluated through electrochemical impedance spectroscopy measurements, using NCP spiked human serum. With a good selectivity the lower detection limit was evidenced as 0.389 fM, at a linear detection range from 1 fM to 100 pM. The stability, and reusability of the aptasensor were demonstrated, showing ∼30% and ∼33% loss of active state, respectively, after ∼11 days. The detection of NCP was evaluated by comparing anti-NCP aptamer and antibody as the bioprobes. The determination coefficients of R2 = 0.9759 and R2 = 0.9772 were obtained for aptamer- and antibody-based sensing, respectively. Moreover, the genuine interaction of NCP aptamer and protein was validated by enzyme linked apta-sorbent assay. The aptasensing strategy proposed with AuIDE/diamond enhanced sensing platform is highly recommended for early diagnosis of SARS-CoV-2 infection.
Collapse
Affiliation(s)
- Santheraleka Ramanathan
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), 01000, Kangar, Perlis, Malaysia
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), 01000, Kangar, Perlis, Malaysia; Faculty of Chemical Engineering Technology, Universiti Malaysia Perlis (UniMAP), 02600, Arau, Perlis, Malaysia.
| | - Zool Hilmi Ismail
- Centre for Artificial Intelligence and Robotics, Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100, Kuala Lumpur, Malaysia.
| | - M K Md Arshad
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), 01000, Kangar, Perlis, Malaysia; Faculty of Electronic Engineering Technology, Universiti Malaysia Perlis (UniMAP), 02600, Arau, Pauh Putra, Perlis, Malaysia
| | - Prabakaran Poopalan
- Faculty of Electronic Engineering Technology, Universiti Malaysia Perlis (UniMAP), 02600, Arau, Pauh Putra, Perlis, Malaysia
| |
Collapse
|
10
|
Özyurt C, Uludağ İ, İnce B, Sezgintürk MK. Biosensing strategies for diagnosis of prostate specific antigen. J Pharm Biomed Anal 2022. [DOI: 10.1016/j.jpba.2021.114535
expr 871894585 + 891234880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/16/2023]
|
11
|
Agrahari S, Kumar Gautam R, Kumar Singh A, Tiwari I. Nanoscale materials-based hybrid frameworks modified electrochemical biosensors for early cancer diagnostics: An overview of current trends and challenges. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106980] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
12
|
Özyurt C, Uludağ İ, İnce B, Sezgintürk MK. Biosensing strategies for diagnosis of prostate specific antigen. J Pharm Biomed Anal 2021; 209:114535. [PMID: 34954466 DOI: 10.1016/j.jpba.2021.114535] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 11/29/2021] [Accepted: 12/09/2021] [Indexed: 01/05/2023]
Abstract
Almost from the time of its discovery, the prostate specific antigen (PSA) has been one of the most accurate and most extensively studied indicators of prostate cancer (PC). Because of advancements in biosensing systems and technology, PSA analysis methods have been substantially updated and enhanced as compared to their first instances. With the development of techniques in biosensor technology, the number of PSA biosensors that can be used in the biomedical sector is increasing year by year. Many different recognition elements and transducers have been used in the development of biosensor systems that exhibit high sensitivity, selectivity, and specificity. Here in this review, we provide a current overview of the different approaches to PSA detection.
Collapse
Affiliation(s)
- Canan Özyurt
- Department of Chemistry and Chemical Processing Technologies, Lapseki Vocational School, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - İnci Uludağ
- Bioengineering Department, Engineering Faculty, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Bahar İnce
- Bioengineering Department, Engineering Faculty, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Mustafa Kemal Sezgintürk
- Bioengineering Department, Engineering Faculty, Çanakkale Onsekiz Mart University, Çanakkale, Turkey.
| |
Collapse
|
13
|
Bi H, Bian P, Gopinath SCB, Marimuthu K, Lv G, Yin X. Identifying mineral decrement with bone injury by quantifying osteocalcin on current-volt sensor. Biotechnol Appl Biochem 2021; 69:2061-2068. [PMID: 34622990 DOI: 10.1002/bab.2267] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 09/28/2021] [Indexed: 11/08/2022]
Abstract
Osteoporosis, a bone disease is caused by the deterioration of bone and shows an enhanced risk of bone fracture and decreasing bone mineral density. Unfortunately, the available radiological techniques are expensive, and have disadvantages such as radiation intake, need a specialist to handle the instrument, and so forth. This research is focused to develop a point-of-care system to identify osteocalcin on current-volt sensor, which helps to diagnose the bone metabolism and prognostics. Antiosteocalcin antibody was attached on the electrode through the silane-modified iron material. The antibody-immobilized sensing surface was utilized to identify the level of osteocalcin and the detection limit of 100 pg/ml reached on linear concentrations of 0.01-3000 ng/ml. Calculations were made by triplicates (n = 3; 3δ) on the determination coefficient of y = 0.2637x-0.6012; R2 = 0.9319. Further, control proteins failed to bind with immobilized antibody, confirmed by the specific osteocalcin detection. This research is to identify the osteoporosis biomarker and to help determine the conditions with osteoporosis.
Collapse
Affiliation(s)
- Huanjie Bi
- The Second Department of Orthopedics, Tangshan Gongren Hospital, Tangshan, Hebei, China
| | - Peimin Bian
- Department of Medical Rehabilitation, The 5th People's Hospital of Jinan, Jinan, Shandong, China
| | - Subash C B Gopinath
- Faculty of Chemical Engineering Technology, Universiti Malaysia Perlis (UniMAP), Arau, Perlis, 02600, Malaysia.,Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, 01000, Malaysia
| | - Kasi Marimuthu
- Department of Biotechnology, Faculty of Applied Sciences, AIMST University, Bedong, Kedah, Malaysia
| | - Genbing Lv
- Department of Orthopedics, Sun Si Miao Hospital of Beijing University of Chinese Medicine, Tongchuan Traditional Chinese Medicine Hospital, Tongchuan, Shaanxi, China
| | - XinHua Yin
- Department of Spine Surgery, HongHui Hospital, Xi'an Jiaotong University College of Medicine, Xi'an, Shaanxi, China
| |
Collapse
|
14
|
Abd Rahman SF, Khairuddin Md Arshad M, Gopinath SC, Faris Mohamad Fathil M, Sarry F, Md Nor MN. Impedimetric Lectin Biosensor for Prostate Cancer Detection. 2021 IEEE INTERNATIONAL CONFERENCE ON SENSORS AND NANOTECHNOLOGY (SENNANO) 2021. [DOI: 10.1109/sennano51750.2021.9642659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
15
|
Yin M, Xu D, Yu J, Huang S, Gopinath SCB, Kang P. Impedance spectroscopy for identifying tau protein to monitor anesthesia-based issues. Biotechnol Appl Biochem 2021; 69:1805-1811. [PMID: 34453342 DOI: 10.1002/bab.2246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 08/23/2021] [Indexed: 11/10/2022]
Abstract
Anesthesia-related drugs cause various side effects and health-related illnesses after surgery. In particular, neurogenerative disorder is a common problem of anesthesia-related drugs. A patient gets anesthesia as a requirement of the preoperative evaluation to diagnose the medical illness, which is caused by anesthetic drug treatment. Different blood-based biomarkers help in identifying the changes appearing in patients after anesthesia treatment. Among them, tau protein is a sensitive biomarker of neurodegenerative diseases, and the fluctuations in tau proteins are highly associated with various diseases. Furthermore, researchers have found unstable levels of tau protein after the anesthesia process. The current research has focused on quantifying tau protein via impedance spectroscopy to identify the problems caused by anesthesia-related drugs. An impedance spectroscopy electrode was modified into a multiwalled carbon nanotube, and an amine-ended aptamer was then attached. This electrode surface was used to quantify the tau protein level and reached the detection limit of 1 fM. The determination coefficient was found to be y = 369.93x + 1144.9, with R2 = 0.9846 in the linear range of 1 fM-1 nM. Furthermore, tau protein spiked human serum was clearly identified on the immobilized aptamer surface, indicating the specific detection.
Collapse
Affiliation(s)
- Miaomiao Yin
- Department of Anesthesiology, Lianyungang Hospital Affiliated to Xuzhou Medical University, Lianyungang, Jiangsu, China
| | - Defang Xu
- Department of Anesthesiology, Tianjin Fourth Center Hospital, Tianjin, China
| | - Jinyong Yu
- Department of Anesthesiology, Zhucheng Maternal and Child Health Hospital, Weifang, Shandong, China
| | - Saisai Huang
- Department of Anesthesiology, Affiliated Hospital of Nantong University, Nantong, Jiangsu, China
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, 01000, Malaysia.,Faculty of Chemical Engineering Technology, Universiti Malaysia Perlis (UniMAP), Arau, Perlis, 02600, Malaysia
| | - Peipei Kang
- Department of Anesthesiology, Nantong Tumor Hospital, Affiliated Tumor Hospital of Nantong University, Nantong, Jiangsu, China
| |
Collapse
|
16
|
Uda MNA, Gopinath SCB, Hashim U, Halim NH, Parmin NA, Uda MNA, Adam T, Anbu P. Silica and graphene mediate arsenic detection in mature rice grain by a newly patterned current-volt aptasensor. Sci Rep 2021; 11:14688. [PMID: 34282233 PMCID: PMC8289824 DOI: 10.1038/s41598-021-94145-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Accepted: 07/07/2021] [Indexed: 02/06/2023] Open
Abstract
Arsenic is a major global threat to the ecosystem. Here we describe a highly accurate sensing platform using silica nanoparticles/graphene at the surface of aluminum interdigitated electrodes (Al IDE), able to detect trace amounts of arsenic(III) in rice grain samples. The morphology and electrical properties of fabricated Al IDEs were characterized and standardized using AFM, and SEM with EDX analyses. Micrometer scale Al IDEs were fabricated with silicon, aluminum, and oxygen as primary elements. Validation of the bare Al IDE with electrolyte fouling was performed at different pH levels. The sensing surface was stable with no electrolyte fouling at pH 7. Each chemical modification step was monitored with current-volt measurement. The surface chemical bonds were characterized by fourier transform infrared spectroscopy (FTIR) and revealed different peaks when interacting with arsenic (1600-1000 cm-1). Both silica nanoparticles and graphene presented a sensitive limit of detection as measured by slope calibration curves at 0.0000001 pg/ml, respectively. Further, linear regression was established using ΔI (A) = 3.86 E-09 log (Arsenic concentration) [g/ml] + 8.67 E-08 [A] for silica nanoparticles, whereas for graphene Y = 3.73 E-09 (Arsenic concentration) [g/ml] + 8.52 E-08 on the linear range of 0.0000001 pg/ml to 0.01 pg/ml. The R2 for silica (0.96) and that of graphene (0.94) was close to the maximum (1). Modification with silica nanoparticles was highly stable. The potential use of silica nanoparticles in the detection of arsenic in rice grain extract can be attributed to their size and stability.
Collapse
Affiliation(s)
- M. N. A. Uda
- grid.430704.40000 0000 9363 8679Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis Malaysia ,grid.430704.40000 0000 9363 8679Faculty of Chemical Engineering Technology, Universiti Malaysia Perlis, 02600 Arau, Perlis Malaysia
| | - Subash C. B. Gopinath
- grid.430704.40000 0000 9363 8679Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis Malaysia ,grid.430704.40000 0000 9363 8679Faculty of Chemical Engineering Technology, Universiti Malaysia Perlis, 02600 Arau, Perlis Malaysia
| | - Uda Hashim
- grid.430704.40000 0000 9363 8679Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis Malaysia
| | - N. H. Halim
- grid.430704.40000 0000 9363 8679Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis Malaysia
| | - N. A. Parmin
- grid.430704.40000 0000 9363 8679Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis Malaysia
| | - M. N. Afnan Uda
- grid.430704.40000 0000 9363 8679Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis Malaysia
| | - Tijjani Adam
- grid.430704.40000 0000 9363 8679Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis Malaysia ,grid.430704.40000 0000 9363 8679Faculty of Electronics Engineering Technology, Universiti Malaysia Perlis, 02600 Arau, Perlis Malaysia
| | - Periasamy Anbu
- grid.202119.90000 0001 2364 8385Department of Biological Engineering, College of Engineering, Inha University, Incheon, Republic of Korea
| |
Collapse
|
17
|
Özcan B, Sezgintürk MK. Highly Sensitive and Single-Use Biosensing System Based on a GP Electrode for Analysis of Adiponectin, an Obesity Biomarker. ACS Biomater Sci Eng 2021; 7:3658-3668. [PMID: 34260213 DOI: 10.1021/acsbiomaterials.1c00094] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
This study presents a disposable, novel, and sensitive biosensing system to determine adiponectin, an obesity biomarker, in real human serum. The graphite paper (GP) working electrode is a new material for impedimetric biosensors. In the literature, there is no study in which this electrode is used in impedance-based biosensors for adiponectin detection. Sensitive and useful techniques, such as electrochemical impedance spectroscopy and cyclic voltammetry, were utilized for investigation of the modification of the GP electrode surface and optimization and characterization of the constructed biosensor. The single frequency impedance technique was used to study the interactions between antiadiponectin and adiponectin. The morphology of the electrode surface for each immobilization step was examined with scanning electron microscopy. All experimental parameters were optimized to fabricate a rapid and sensitive biosensing system. The designed biosensor presents excellent performance with a wide detection range (0.05-25 pg mL-1) and a low limit of detection (0.0033 pg mL-1) for adiponectin determination. Also, it has been demonstrated that the biosensor sensitively allows for the detection of adiponectin in human serum. The affinity of the designed immunosensor toward other proteins and components was examined in the presence of the target protein (adiponectin), leptin (100 pg mL-1), creatine kinase (50 pg mL-1), parathyroid hormone (50 pg mL-1), and d-glucose (0.5 M). The selectivity of the adiponectin biosensor resulted in high capacity to neglect the interference effect. The constructed biosensor showed good linearity, long-term storage life (10 weeks), high reusability (18 times regenerability), and high ability to detect adiponectin concentrations at picogram levels.
Collapse
Affiliation(s)
- Burcu Özcan
- Faculty of Engineering, Bioengineering Department, Çanakkale Onsekiz Mart University, 17020 Çanakkale, Turkey
| | - Mustafa Kemal Sezgintürk
- Faculty of Engineering, Bioengineering Department, Çanakkale Onsekiz Mart University, 17020 Çanakkale, Turkey
| |
Collapse
|
18
|
Islam T, Hasan MM, Awal A, Nurunnabi M, Ahammad AJS. Metal Nanoparticles for Electrochemical Sensing: Progress and Challenges in the Clinical Transition of Point-of-Care Testing. Molecules 2020; 25:E5787. [PMID: 33302537 PMCID: PMC7763225 DOI: 10.3390/molecules25245787] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 11/23/2020] [Accepted: 12/04/2020] [Indexed: 02/08/2023] Open
Abstract
With the rise in public health awareness, research on point-of-care testing (POCT) has significantly advanced. Electrochemical biosensors (ECBs) are one of the most promising candidates for the future of POCT due to their quick and accurate response, ease of operation, and cost effectiveness. This review focuses on the use of metal nanoparticles (MNPs) for fabricating ECBs that has a potential to be used for POCT. The field has expanded remarkably from its initial enzymatic and immunosensor-based setups. This review provides a concise categorization of the ECBs to allow for a better understanding of the development process. The influence of structural aspects of MNPs in biocompatibility and effective sensor design has been explored. The advances in MNP-based ECBs for the detection of some of the most prominent cancer biomarkers (carcinoembryonic antigen (CEA), cancer antigen 125 (CA125), Herceptin-2 (HER2), etc.) and small biomolecules (glucose, dopamine, hydrogen peroxide, etc.) have been discussed in detail. Additionally, the novel coronavirus (2019-nCoV) ECBs have been briefly discussed. Beyond that, the limitations and challenges that ECBs face in clinical applications are examined and possible pathways for overcoming these limitations are discussed.
Collapse
Affiliation(s)
- Tamanna Islam
- Department of Chemistry, Jagannath University, Dhaka 1100, Bangladesh; (T.I.); (M.M.H.); (A.A.)
| | - Md. Mahedi Hasan
- Department of Chemistry, Jagannath University, Dhaka 1100, Bangladesh; (T.I.); (M.M.H.); (A.A.)
| | - Abdul Awal
- Department of Chemistry, Jagannath University, Dhaka 1100, Bangladesh; (T.I.); (M.M.H.); (A.A.)
| | - Md Nurunnabi
- Department of Pharmaceutical Sciences, School of Pharmacy, University of Texas at El Paso, El Paso, TX 79902, USA
- Department of Biomedical Engineering, University of Texas at El Paso, El Paso, TX 79968, USA
- Department of Environmental Science & Engineering, University of Texas at El Paso, El Paso, TX 79968, USA
| | - A. J. Saleh Ahammad
- Department of Chemistry, Jagannath University, Dhaka 1100, Bangladesh; (T.I.); (M.M.H.); (A.A.)
| |
Collapse
|