1
|
Nasrallah GK, Al-Buainain R, Younes N, Dargham SR, Al-Sadeq DW, Elhassan M, Al-Shaar I, Yassine HM, Abu-Raddad LJ, Emara MM, Ismail A. Screening and diagnostic testing protocols for HIV and Syphilis infections in health care setting in Qatar: Evaluation and recommendations. PLoS One 2023; 18:e0278079. [PMID: 36749795 PMCID: PMC9904467 DOI: 10.1371/journal.pone.0278079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Accepted: 12/22/2022] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND HIV and Syphilis are common STIs, which have become a concern and burden on healthcare systems, as many infections go untreated and lead to potentially serious complications. HIV is usually diagnosed with Western blot, PCR, and p24 antigen testing. Whereas, Syphilis is mainly diagnosed through clinical findings and serologic testing. The Medical Commission Department (MC) under MOPH is responsible for screening all newcomers to Qatar, aiming to keep the country free from serious infectious diseases. OBJECTIVE We aimed to evaluate the diagnostic efficiency of the protocols used in the MC for screening HIV and Syphilis infections. METHODS We conducted a retrospective study of samples analyzed by 4th Generation ARCHITECT® HIV Ag/Ab Combo and Rapid Plasma Reagin (RPR) between January to December 2019. ARCHITECT® HIV Ag/Ab Combo positive samples were confirmed by INNO-LIA™ HIVI/II and RT-PCR. RPR-reactive samples were confirmed by ARCHITECT® Syphilis Treponema pallidium Antibody (Syphilis TPA) assay. RESULTS For HIV, data were collected from 585,587 individuals, of which 595 (0.1%) were positive by the ARCHITECT® HIV Ag/Ab Combo (Analyzer A). When all initially positive sera were re-tested on newly collected blood samples using different ARCHITECT® HIV Ag/Ab Combo analyzer (analyzer B), 99.8% (594/595) of samples were also positive, suggesting high reproducibility. The positive predictive value (PPV) between ARCHITECT® HIV Ag/Ab Combo and the INNO-LIA™ HIVI/II confirmatory assay was 31.8%. The PPV between ARCHITECT® HIV Ag/Ab Combo and HIV-PCR assay was 26.8%. Retrospective data for Syphilis were collected from a total of 97,298 individuals who visited the MC, of which 198 (0.20%) were initially positive by RPR. The PPV between RPR and Syphilis TPA confirmatory assay was 36.6%. CONCLUSION Despite the high rate of false positivity using ARCHITECT® HIV Ag/Ab Combo and RPR screening assays, both assays have proven to be highly effective as screening testing methods.
Collapse
Affiliation(s)
- Gheyath K. Nasrallah
- Department of Biomedical Science, College of Health Sciences, QU Health, Qatar University, Doha, Qatar
- Biomedical Research Center, Qatar University, Doha, Qatar
- * E-mail: , (AI); (GKN)
| | - Raniya Al-Buainain
- Medical Commission Department, Laboratory Section, Ministry of Public Health, Doha, Qatar
| | - Nadin Younes
- Department of Biomedical Science, College of Health Sciences, QU Health, Qatar University, Doha, Qatar
- Biomedical Research Center, Qatar University, Doha, Qatar
| | - Soha R. Dargham
- Infectious Disease Epidemiology Group, Weill Cornell Medicine-Qatar, Cornell University, Doha, Qatar
- World Health Organization Collaborating Centre for Disease Epidemiology Analytics on HIV/AIDS, Sexually Transmitted Infections, and Viral Hepatitis, Weill Cornell Medicine–Qatar, Cornell University, Doha, Qatar
| | - Duaa W. Al-Sadeq
- Biomedical Research Center, Qatar University, Doha, Qatar
- College of Medicine, QU Health, Qatar University, Doha, Qatar
| | - Mohamed Elhassan
- Medical Commission Department, Laboratory Section, Ministry of Public Health, Doha, Qatar
| | - Ibrahim Al-Shaar
- Medical Commission Department, Laboratory Section, Ministry of Public Health, Doha, Qatar
| | - Hadi M. Yassine
- Department of Biomedical Science, College of Health Sciences, QU Health, Qatar University, Doha, Qatar
- Biomedical Research Center, Qatar University, Doha, Qatar
| | - Laith J. Abu-Raddad
- Infectious Disease Epidemiology Group, Weill Cornell Medicine-Qatar, Cornell University, Doha, Qatar
- World Health Organization Collaborating Centre for Disease Epidemiology Analytics on HIV/AIDS, Sexually Transmitted Infections, and Viral Hepatitis, Weill Cornell Medicine–Qatar, Cornell University, Doha, Qatar
| | | | - Ahmed Ismail
- Medical Commission Department, Laboratory Section, Ministry of Public Health, Doha, Qatar
- * E-mail: , (AI); (GKN)
| |
Collapse
|
2
|
Santana GM, Silva AKS, Foguel MV, Dutra RF. An ultrasensitive electrochemical immunosensor for hepatitis C antibodies based on one-step-eletrosynthetized polypyrrole-graphene nanocomposite. JOURNAL OF MATERIALS SCIENCE 2022; 57:5586-5595. [PMID: 35250090 PMCID: PMC8882041 DOI: 10.1007/s10853-022-06992-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Accepted: 02/08/2022] [Indexed: 06/14/2023]
Abstract
UNLABELLED An ultrasensitive label-free electrochemical immunosensor was developed for hepatitis C antibodies (anti-HCV). Worldwide, it is estimated 71 million people have HCV infection in a chronic stage that may lead to cirrose and cancer. To achieve HCV elimination, health programs should include screening testing based on anti-HCV detection allowing the early-stage treatment. The immunosensor was based on a graphene oxide-polypyrrole (PPy-GO) film one-step electropolymerized on the electrode surface. Ultrasensitive anti-HCV detection was ensured by HCV antigen conjugated to biotin that was immobilized in a great amount on streptavidin-coated nanostructured surface. Analytical responses were obtained by anodic peaks from the square wave voltammetry in the presence of ferrocyanide/ferricyanide as a redox probe. This immunosensor exhibited a linear range from 2 to 14 ng mL-1 of anti-HCV and a limit of detection in the clinical range (1.63 ng mL-1). Furthermore, the immunosensor presented an efficient performance for the determination of anti-HCV in spiked serum samples, becoming this developed nanosensor as potential tools for early HCV diagnosis and screening. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s10853-022-06992-5.
Collapse
Affiliation(s)
- Gilvânia M. Santana
- Biomedical Engineering Laboratory, Federal University of Pernambuco, Av. Professor Moraes Rego, Recife, PE 50670-901 Brazil
| | - Anne K. S. Silva
- Biomedical Engineering Laboratory, Federal University of Pernambuco, Av. Professor Moraes Rego, Recife, PE 50670-901 Brazil
| | - Marcos V. Foguel
- Biomedical Engineering Laboratory, Federal University of Pernambuco, Av. Professor Moraes Rego, Recife, PE 50670-901 Brazil
| | - Rosa F. Dutra
- Biomedical Engineering Laboratory, Federal University of Pernambuco, Av. Professor Moraes Rego, Recife, PE 50670-901 Brazil
| |
Collapse
|
3
|
Ma L, Abugalyon Y, Li X. Multicolorimetric ELISA biosensors on a paper/polymer hybrid analytical device for visual point-of-care detection of infection diseases. Anal Bioanal Chem 2021; 413:4655-4663. [PMID: 33903943 PMCID: PMC8075012 DOI: 10.1007/s00216-021-03359-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 04/13/2021] [Accepted: 04/16/2021] [Indexed: 12/13/2022]
Abstract
Enzyme-linked immunosorbent assay (ELISA) is widely used for the detection of disease biomarkers. However, it utilizes time-consuming procedures and expensive instruments, making it infeasible for point-of-care (POC) analysis especially in resource-limited settings. In this work, a multicolorimetric ELISA biosensor integrated on a paper/polymer hybrid microfluidic device was developed for rapid visual detection of disease biomarkers at point of care, without using costly equipment. This multicolormetric ELISA platform was built on multiple distinct color variants resulted from the catalytic oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) and the etching of gold nanorods (AuNRs). The vivid color changes could be easily distinguished by the naked eye, and their red mean values allowed quantitative biomarker detection, without using any sophisticated instruments. When this multicolorimetric ELISA was integrated on a paper/polymer hybrid analytical device, it not only provided integrated processing and high portability but also enabled fast assays in about 50 min due to the unique advantages of paper/polymer hybrid devices. The limit of detection of 9.1 ng/μL of the hepatitis C virus core antigen, a biomarker for hepatitis C, was achieved using this multicolorimetric ELISA platform. This multicolor ELISA analytical device provides a new versatile, user-friendly, affordable, and portable immunosensing platform with high potential for on-site detections of various viruses, proteins, and biomarkers for low-resource settings such as at home, public venues, rural areas, and developing nations.
Collapse
Affiliation(s)
- Lei Ma
- Deparment of Chemistry and Biochemistry, The University of Texas at El Paso, 500 West University Ave, El Paso, TX, 79968, USA
| | - Yousef Abugalyon
- Deparment of Chemistry and Biochemistry, The University of Texas at El Paso, 500 West University Ave, El Paso, TX, 79968, USA
| | - XiuJun Li
- Deparment of Chemistry and Biochemistry, The University of Texas at El Paso, 500 West University Ave, El Paso, TX, 79968, USA. .,Department of Chemistry and Biochemistry, Border Biomedical Research Center, Environmental Science and Engineering, University of Texas at El Paso, 500 West University Ave, El Paso, TX, 79968, USA.
| |
Collapse
|
4
|
Narayanamurthy V, Jeroish ZE, Bhuvaneshwari KS, Samsuri F. Hepatitis C virus (HCV) diagnosis via microfluidics. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:740-763. [PMID: 33511975 DOI: 10.1039/d0ay02045a] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Humans are subjected to various diseases; hence, proper diagnosis helps avoid further disease consequences. One such severe issue that could cause significant damage to the human liver is the hepatitis C virus (HCV). Several techniques are available to detect HCV under various categories, such as detection through antibodies, antigens, and RNA. Although immunoassays play a significant role in discovering hepatitis viruses, there is a need for point-of-care tests (POCT). Some developing strategies are required to ensure the appropriate selection of POCT for HCV detection, initiate appropriate antiviral therapy, and define associated risks, which will be critical in achieving optimal outcomes. Though molecular assays are precise, reproducible, sensitive, and specific, alternative strategies are required to enhance HCV diagnosis among the infected population. Herein, we described and assessed the potential of various microfluidic detection techniques and confirmatory approaches used in present communities. In addition, current key market players in HCV chip-based diagnosis and the future perspectives on the basis of which the diagnosis can be made easier are presented in the present review.
Collapse
Affiliation(s)
- Vigneswaran Narayanamurthy
- Fakulti Teknologi Kejuruteraan Elektrik dan Elektronik, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka, Malaysia.
| | | | | | | |
Collapse
|
5
|
Novelo-Garza B, Duque-Rodríguez J, Mejía-Domínguez AM, Rivas-González MR, Torres-Torres O. Blood safety in Mexico and a perspective on Latin America. Transfus Apher Sci 2019; 58:102661. [PMID: 31757664 DOI: 10.1016/j.transci.2019.10.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 10/08/2019] [Accepted: 10/16/2019] [Indexed: 12/22/2022]
Abstract
Blood safety has been of paramount concern worldwide over the last decades, and Latin America and Mexico are no exception. Factors of utmost importance include the use of highly efficient screening tests and the encouragement of voluntary donation. This review summarizes the current situation in Latin America and particularly in Mexico with respect to these key issues. Except for some specific regions, there is a lack of progress of voluntary donation in Mexico compared with other Latin American countries. A more efficient voluntary donation system could provide donors with lower prevalence of infectious agents such as human immunodeficiency, hepatitis B, and hepatitis C viruses. In Latin America, and specifically in countries such as Argentina, Brazil and Nicaragua, voluntary donation and blood safety are strongly encouraged. However, to date, in Mexico there has not been a specific blood safety project because of fragmentation of the health system model with structural differences among organisations. Although national policies are established to grant health coverages in Mexico, blood safety is still limited and outdated because of oversights in technical fields and regulations. Individual molecular biological tests for donor screening have recently been incorporated into the Mexican national regulations. Although the routine use of these tests as part of effective donor screening is still not compulsory, it is enabling a progressive improvement of blood safety.
Collapse
Affiliation(s)
- Bárbara Novelo-Garza
- Central Blood Bank, Centro Médico Nacional La Raza [La Raza National Medical Centre], Mexico City, Mexico
| | - Jorge Duque-Rodríguez
- Postgraduate Department, Faculty of Medicine and Biological Sciences, Universidad Autónoma de Chihuahua, State Blood Transfusion Centre, Chihuahua, Mexico.
| | - Ana-María Mejía-Domínguez
- Blood Bank, Instituto Nacional de Cardiología "Ignacio Chávez" ["Ignacio Chávez" National Institute of Cardiology], Mexico City, Mexico
| | - María-Rita Rivas-González
- Blood Bank, Hospital de Alta Especialidad "Centenario de la Revolución Mexicana" ["Centenary of the Mexican Revolution" Highly Specialised Hospital], Morelos, Mexico
| | - Oscar Torres-Torres
- Central Blood Bank, Centro Médico Nacional de Occidente [National Medical Centre of the West], Guadalajara, Mexico
| |
Collapse
|
6
|
|
7
|
A label-free and reagentless immunoelectrode for antibodies against hepatitis B core antigen (anti-HBc) detection. Colloids Surf B Biointerfaces 2018; 172:272-279. [DOI: 10.1016/j.colsurfb.2018.08.050] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Revised: 08/15/2018] [Accepted: 08/23/2018] [Indexed: 01/12/2023]
|
8
|
Levitsky J, Formica RN, Bloom RD, Charlton M, Curry M, Friedewald J, Friedman J, Goldberg D, Hall S, Ison M, Kaiser T, Klassen D, Klintmalm G, Kobashigawa J, Liapakis A, O'Conner K, Reese P, Stewart D, Terrault N, Theodoropoulos N, Trotter J, Verna E, Volk M. The American Society of Transplantation Consensus Conference on the Use of Hepatitis C Viremic Donors in Solid Organ Transplantation. Am J Transplant 2017; 17:2790-2802. [PMID: 28556422 DOI: 10.1111/ajt.14381] [Citation(s) in RCA: 247] [Impact Index Per Article: 35.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2017] [Revised: 05/12/2017] [Accepted: 05/18/2017] [Indexed: 01/25/2023]
Abstract
The availability of direct-acting antiviral agents for the treatment of hepatitis C virus (HCV) infection has resulted in a profound shift in the approach to the management of this infection. These changes have affected the practice of solid organ transplantation by altering the framework by which patients with end-stage organ disease are managed and receive organ transplants. The high level of safety and efficacy of these medications in patients with chronic HCV infection provides the opportunity to explore their use in the setting of transplanting organs from HCV-viremic patients into non-HCV-viremic recipients. Because these organs are frequently discarded and typically come from younger donors, this approach has the potential to save lives on the solid organ transplant waitlist. Therefore, an urgent need exists for prospective research protocols that study the risk versus benefit of using organs for hepatitis C-infected donors. In response to this rapidly changing practice and the need for scientific study and consensus, the American Society of Transplantation convened a meeting of experts to review current data and develop the framework for the study of using HCV viremic organs in solid organ transplantation.
Collapse
Affiliation(s)
| | | | - R D Bloom
- University of Pennsylvania, Philadelphia, PA
| | - M Charlton
- Intermountain Medical Center, Salt Lake City, UT
| | - M Curry
- Beth Israel Deaconess Medical Center, Boston, MA
| | | | - J Friedman
- Optum Population Health Solutions, Minneapolis, MN
| | - D Goldberg
- University of Pennsylvania, Philadelphia, PA
| | - S Hall
- Baylor University Medical Center, Dallas, TX
| | - M Ison
- Northwestern University, Chicago, IL
| | - T Kaiser
- University of Cincinnati, Cincinnati, OH
| | - D Klassen
- United Network of Organ Sharing, Richmond, VA
| | - G Klintmalm
- Baylor University Medical Center, Dallas, TX
| | | | | | | | - P Reese
- University of Pennsylvania, Philadelphia, PA
| | - D Stewart
- United Network of Organ Sharing, Richmond, VA
| | - N Terrault
- University of California San Francisco, San Francisco, CA
| | | | - J Trotter
- Baylor University Medical Center, Dallas, TX
| | - E Verna
- Columbia University, New York, NY
| | - M Volk
- Loma Linda University, San Diego, CA
| |
Collapse
|
9
|
Alshayea AI, Eid GE, El-Hazmi MM, Alhetheel AF. Prevalence and characterization of occult hepatitis B infection among blood donors in central Saudi Arabia. Saudi Med J 2017; 37:1114-9. [PMID: 27652363 DOI: 10.15537/smj.2016.10.14708] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
OBJECTIVES To evaluate the prevalence of occult hepatitis B viral infections (OBIs) among blood donors considering the clinical and epidemiological importance of identifying OBIs. METHODS A cross-sectional study conducted at King Khalid University Hospital, Riyadh, Saudi Arabia between January 2011 and January 2012. Blood donors (n=8501) were screened for Hepatitis B virus surface antigen (HBsAg) and hepatitis B core antibodies (HBcAb). All HBsAg-negative and HBcAb-positive samples were tested further for hepatitis B surface antibodies (HBsAb), hepatitis B virus (HBV)-DNA, and HBV genotyping. RESULTS Of the 8501 serum samples tested, 56 (0.7%) were positive and 8445 (99.3%) were negative for HBsAg. Among the HBsAg-negative samples, 198 (2.3%) were positive for HBcAb and these patients were suspected to have OBIs. Among the HBcAb-positive samples, 119 (60.1%) were positive while 79 (39.9%) were negative for HBsAb. Analysis of HBV-DNA for the suspected OBIs showed that 17 out of 198 samples (8.6%) yielded positive results, and all of them were HBsAb-negative. The viral load was low (less than 20-186 IU/mL) in all OBIs. Hepatitis B virus genotyping showed that 15 out of 17 samples (88.2%) were genotype D, and the other 2 samples (11.8%) were genotype E. CONCLUSION The prevalence of OBIs among blood donors in Riyadh was 0.2%. Therefore, it is recommended that HBV molecular testing should be incorporated with serological assays for screening of blood donors.
Collapse
Affiliation(s)
- Areej I Alshayea
- Department of Clinical Laboratory Sciences, College of Applied Medical Sciences, King Khalid University Hospital, King Saud University, Riyadh, Kingdom of Saudi Arabia. E-mail.
| | | | | | | |
Collapse
|
10
|
Boobalan J, Torti A, Dinesha TR, Solomon SS, Balakrishnan P, Saravanan S. Cost-effective HIV-1 virological monitoring in resource-limited settings using a modified commercially available qPCR RNA assay. J Virol Methods 2017; 248:71-76. [PMID: 28506630 DOI: 10.1016/j.jviromet.2017.05.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2016] [Revised: 05/10/2017] [Accepted: 05/11/2017] [Indexed: 10/19/2022]
Abstract
Virological monitoring through plasma viral load (PVL) quantification is essential for clinical management of HIV patients undergoing antiretroviral treatment (ART), and for detecting treatment failure. Quantitative PCR (qPCR)-based tests are the gold standard for measuring PVL. Largely because of their high cost, however, implementation of these tests in low- and middle-income countries fails to cover the testing demand. In this study, we aimed at reducing the running cost of the commercially available Abbott RealTime™ HIV-1 assay by minimizing the reagent consumption. To this end, a modified version of the assay was obtained by reducing the assay's reagents volume to about a half, and validated using a panel of 104 plasma samples. Compared to the standard version, the modified Abbott assay allowed for a 50% reduction in running costs. At the same time, it showed a 100% concordance in identifying samples with detectable viral load, strong correlation (Pearson's r=0.983, P<0.0001), and a high agreement between PVL values (mean percent difference between PVL values±standard deviation=0.76±3.18%). In detecting viral failure (PVL>1000copiesmL-1), the modified assay showed a sensitivity of 94.6%, a specificity of 93.8%, and a negative and positive predictive values of 93.8% and 94.6%, respectively. The modified assay therefore reliably quantifies PVL, predicts viral failure, and allows for a ca. 50% reduction in the assay's running costs. It may thus be implemented as an ART monitoring tool in resource-limited settings and for research purposes.
Collapse
Affiliation(s)
- Jayaseelan Boobalan
- Y.R. Gaitonde Centre for AIDS Research and Education, Voluntary Health Services Hospital Campus, Taramani, Chennai 600113, India
| | - Andrea Torti
- Y.R. Gaitonde Centre for AIDS Research and Education, Voluntary Health Services Hospital Campus, Taramani, Chennai 600113, India
| | - Thongadi Ramesh Dinesha
- Y.R. Gaitonde Centre for AIDS Research and Education, Voluntary Health Services Hospital Campus, Taramani, Chennai 600113, India
| | - Sunil Suhas Solomon
- Y.R. Gaitonde Centre for AIDS Research and Education, Voluntary Health Services Hospital Campus, Taramani, Chennai 600113, India; Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
| | - Pachamuthu Balakrishnan
- Y.R. Gaitonde Centre for AIDS Research and Education, Voluntary Health Services Hospital Campus, Taramani, Chennai 600113, India
| | - Shanmugam Saravanan
- Y.R. Gaitonde Centre for AIDS Research and Education, Voluntary Health Services Hospital Campus, Taramani, Chennai 600113, India.
| |
Collapse
|
11
|
Das S, Shibib DR, Vernon MO. The new frontier of diagnostics: Molecular assays and their role in infection prevention and control. Am J Infect Control 2017; 45:158-169. [PMID: 28159066 PMCID: PMC7115290 DOI: 10.1016/j.ajic.2016.08.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2016] [Revised: 08/19/2016] [Accepted: 08/19/2016] [Indexed: 01/05/2023]
Abstract
Recent advances in technology over the last decade have propelled the microbiology laboratory into a pivotal role in infection prevention and control. The rapid adaptation of molecular technologies to the field of clinical microbiology now greatly influences infectious disease management and significantly impacts infection control practices. This review discusses recent developments in molecular techniques in the diagnosis of infectious diseases. It describes the basic concepts of molecular assays, discusses their advantages and limitations, and characterizes currently available commercial assays with respect to cost, interpretive requirements, and clinical utility.
Collapse
|
12
|
Ali Z, Wang J, Tang Y, Liu B, He N, Li Z. Simultaneous detection of multiple viruses based on chemiluminescence and magnetic separation. Biomater Sci 2017; 5:57-66. [DOI: 10.1039/c6bm00527f] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In this report, a DNA hybridization based chemiluminescent detection method has been proposed for reliable detection of multiple pathogens. The use of surface modified magnetic nanoparticles can help to integrate this system into an automated platform for high throughput applications.
Collapse
Affiliation(s)
- Zeeshan Ali
- State Key Laboratory of Bioelectronics
- School of Biological Science and Medical Engineering
- Southeast University
- Nanjing 210096
- P. R. China
| | - Jiuhai Wang
- State Key Laboratory of Bioelectronics
- School of Biological Science and Medical Engineering
- Southeast University
- Nanjing 210096
- P. R. China
| | - Yongjun Tang
- School of Applied Chemistry and Biotechnology
- Shenzhen Polytechnic
- Shenzhen 518055
- P. R. China
| | - Bin Liu
- Department of Biomedical Engineering
- School of Basic Medical Sciences
- Nanjing Medical University
- Nanjing 210029
- China
| | - Nongyue He
- State Key Laboratory of Bioelectronics
- School of Biological Science and Medical Engineering
- Southeast University
- Nanjing 210096
- P. R. China
| | - Zhiyang Li
- Department of Clinical Laboratory
- the Affiliated Drum Tower Hospital of Nanjing University Medical School
- Nanjing 210008
- P. R. China
| |
Collapse
|
13
|
Ghosh K, Mishra KK, Trivedi A, Sosa S, Patel K. Assessment of semi-automated nucleic acid testing programme in a Regional Blood Transfusion Centre. Br J Biomed Sci 2016; 74:42-47. [PMID: 27996693 DOI: 10.1080/09674845.2016.1220708] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
BACKGROUND Detection of human immunodeficiency virus type-1 (HIV-1), hepatitis-C (HCV) and hepatitis-B virus (HBV) in the blood donors is crucial. An efficient form of detection is nucleic acid testing (NAT) in blood screening. We assessed the suitability of commercial NAT testing in a developing country, focusing on the Altona RealStar assay and the method of Sacace Biotechnologies. METHODS We have standardised and validated commercially available NAT kits with a semi-automated system for detection of HBV, HCV and HIV-1 in blood donations. The MP-NAT (mini-pool) assay consists of pooling of sample, virus extraction, amplification and detection with commercially available NAT kits. An internal control (IC) is incorporated in the assay to monitor the extraction, target amplification and detection process. RESULTS The sensitivity of the Altona RealStar assay at 10-MP for each viral target was evaluated, HBV showed amplification in all diluted positive samples of 100, 50, 25, 10 and 5 IU/ml. HIV and HCV infected samples showed amplification in all diluted positive samples of 500, 100, 50 and 30 IU/ml. For HIV, out of six diluted samples of 30 IU/ml, five were amplified. A total of 14,170 seronegative blood samples were tested by RealStar PCR kit in 10-MP and 6 (0.042%) samples/pools were positive. A total of 65,362 seronegative blood donations were also tested by kits of Sacace Biotechnologies, in 10-MP and 45 (0.075%) pools were positive. The prevalence of combined NAT yield cases among routine donors was 1 in 1559 donations tested for all the 3 viruses. CONCLUSION The semi-automated combined system for NAT screening assays is robust, sensitive, reproducible, and this gives an additional layer of safety with affordable cost.
Collapse
Affiliation(s)
- Kanjaksha Ghosh
- a Surat Raktadan Kendra & Research Centre , Surat , Gujarat , India
| | | | - Apeksha Trivedi
- a Surat Raktadan Kendra & Research Centre , Surat , Gujarat , India
| | - Sheetal Sosa
- a Surat Raktadan Kendra & Research Centre , Surat , Gujarat , India
| | - Krima Patel
- a Surat Raktadan Kendra & Research Centre , Surat , Gujarat , India
| |
Collapse
|
14
|
Naidoo A, Parboosing R, Moodley P. Real-time polymerase chain reaction optimised for hepatitis C virus detection in dried blood spots from HIV-exposed infants, KwaZulu-Natal, South Africa. Afr J Lab Med 2016; 5:269. [PMID: 28879101 PMCID: PMC5436390 DOI: 10.4102/ajlm.v5i1.269] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Accepted: 01/08/2016] [Indexed: 01/24/2023] Open
Abstract
Background There is a paucity of data on the prevalence of hepatitis C virus (HCV) in children, particularly in sub-Saharan Africa. A major obstacle in resource-limited settings for polymerase chain reaction (PCR) testing is the necessity for specimen transportation and storage at low temperatures. There are numerous recent studies of using real-time HCV PCR for diagnosis and screening of plasma and serum, but few have looked at using dried blood spot (DBS) specimens. Objectives The aim of this study was to optimise a real-time HCV PCR method to detect HCV RNA from infant DBS specimens for use as a tool for HCV surveillance in KwaZulu-Natal, South Africa. Method The LightCycler® 2.0 instrument was used for the HCV PCR using the LightCycler® RNA Master SYBR Green I kit. Template volume, primer concentration and primer annealing temperatures were optimised and the method was used on 179 DBS specimens from HIV-exposed infants in KwaZulu-Natal. Results Primer concentrations adjusted to 0.25 µM and a template volume of 10 µL improved the PCR amplification. Primer annealing temperatures lowered from 65 °C to 58 °C resulted in higher quantities of amplified PCR product. The limit of detection of the optimised HCV PCR assay was between 1200 IU/mL and 3580 IU/mL of HCV RNA. HCV was not detected in any of the 179 DBS specimens. Conclusion The optimised real-time HCV PCR on infant DBS specimens performed well, but HCV was not found in this surveillance study. HIV infection may have little impact on the vertical transmission of HCV in this region.
Collapse
Affiliation(s)
- Anneta Naidoo
- Department of Virology, Nelson R Mandela School of Medicine, School of Laboratory Medicine and Medical Sciences, University of KwaZulu-Natal, Durban, KwaZulu-Natal, South Africa.,National Health Laboratory Services, Inkosi Albert Luthuli Central Hospital, Durban, KwaZulu-Natal, South Africa
| | - Raveen Parboosing
- Department of Virology, Nelson R Mandela School of Medicine, School of Laboratory Medicine and Medical Sciences, University of KwaZulu-Natal, Durban, KwaZulu-Natal, South Africa.,National Health Laboratory Services, Inkosi Albert Luthuli Central Hospital, Durban, KwaZulu-Natal, South Africa
| | - Pravi Moodley
- Department of Virology, Nelson R Mandela School of Medicine, School of Laboratory Medicine and Medical Sciences, University of KwaZulu-Natal, Durban, KwaZulu-Natal, South Africa.,National Health Laboratory Services, Inkosi Albert Luthuli Central Hospital, Durban, KwaZulu-Natal, South Africa
| |
Collapse
|
15
|
Rajput MK. Automated Triplex (HBV, HCV and HIV) NAT Assay Systems for Blood Screening in India. J Clin Diagn Res 2016; 10:KE01-4. [PMID: 27042485 DOI: 10.7860/jcdr/2016/16981.7319] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2015] [Accepted: 01/08/2016] [Indexed: 12/13/2022]
Abstract
This review is confined to triplex nucleic acid testing (NAT) assays to be used on fully automated platform. Around the world, these assays are being used at various transfusion medicine centres or blood banks to screen blood units for HBV, HCV and HIV. These assay systems can screen up to 1000 blood units for HBV, HCV and HIV simultaneously in a day. This area has been dominated by mainly two manufacturers: M/s Gen-Probe-Novartis and M/s Roche Molecular Systems. The triplex NAT assay systems of both manufacturers are licensed by United States Food and Drug Administration. There is not much awareness about the technology and procedures used in these assays. The main objective of this review is to create awareness about the technology and procedure of these assays.
Collapse
|
16
|
Villar LM, Cruz HM, Barbosa JR, Bezerra CS, Portilho MM, Scalioni LDP. Update on hepatitis B and C virus diagnosis. World J Virol 2015; 4:323-42. [PMID: 26568915 PMCID: PMC4641225 DOI: 10.5501/wjv.v4.i4.323] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2015] [Revised: 09/25/2015] [Accepted: 10/23/2015] [Indexed: 02/05/2023] Open
Abstract
Viral hepatitis B and C virus (HBV and HCV) are responsible for the most of chronic liver disease worldwide and are transmitted by parenteral route, sexual and vertical transmission. One important measure to reduce the burden of these infections is the diagnosis of acute and chronic cases of HBV and HCV. In order to provide an effective diagnosis and monitoring of antiviral treatment, it is important to choose sensitive, rapid, inexpensive, and robust analytical methods. Primary diagnosis of HBV and HCV infection is made by using serological tests for detecting antigens and antibodies against these viruses. In order to confirm primary diagnosis, to quantify viral load, to determine genotypes and resistance mutants for antiviral treatment, qualitative and quantitative molecular tests are used. In this manuscript, we review the current serological and molecular methods for the diagnosis of hepatitis B and C.
Collapse
|
17
|
Li HC, Lo SY. Hepatitis C virus: Virology, diagnosis and treatment. World J Hepatol 2015; 7:1377-1389. [PMID: 26052383 PMCID: PMC4450201 DOI: 10.4254/wjh.v7.i10.1377] [Citation(s) in RCA: 89] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2014] [Revised: 12/22/2014] [Accepted: 04/02/2015] [Indexed: 02/06/2023] Open
Abstract
More than twenty years of study has provided a better understanding of hepatitis C virus (HCV) life cycle, including the general properties of viral RNA and proteins. This effort facilitates the development of sensitive diagnostic tools and effective antiviral treatments. At present, serologic screening test is recommended to perform on individuals in the high risk groups and nucleic acid tests are recommended to confirm the active HCV infections. Quantization and genotyping of HCV RNAs are important to determine the optimal duration of anti-viral therapy and predict the likelihood of response. In the early 2000s, pegylated interferon plus ribavirin became the standard anti-HCV treatment. However, this therapy is not ideal. To 2014, boceprevir, telaprevir, simeprevir, sofosbuvir and Harvoni are approved by Food and Drug Administration for the treat of HCV infections. It is likely that the new all-oral, interferon-free, pan-genotyping anti-HCV therapy will be available within the next few years. Majority of HCV infections will be cured by these anti-viral treatments. However, not all patients are expected to be cured due to viral resistance and the high cost of antiviral treatments. Thus, an efficient prophylactic vaccine will be the next challenge in the fight against HCV infection.
Collapse
|