1
|
Zhang L, Cheng Z, Xu D, Wang Z, Cai S, Hu N, Ma J, Mei X. Developing an AI-assisted digital auscultation tool for automatic assessment of the severity of mitral regurgitation: protocol for a cross-sectional, non-interventional study. BMJ Open 2024; 14:e074288. [PMID: 38553085 PMCID: PMC10982737 DOI: 10.1136/bmjopen-2023-074288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Accepted: 03/11/2024] [Indexed: 04/02/2024] Open
Abstract
INTRODUCTION Mitral regurgitation (MR) is the most common valvular heart disorder, with a morbidity rate of 2.5%. While echocardiography is commonly used in assessing MR, it has many limitations, especially for large-scale MR screening. Cardiac auscultation with electronic stethoscope and artificial intelligence (AI) can be a fast and economical modality for assessing MR severity. Our objectives are (1) to establish a deep neural network (DNN)-based cardiac auscultation method for assessing the severity of MR; and (2) to quantitatively measure the performance of the developed AI-based MR assessment method by virtual clinical trial. METHODS AND ANALYSIS In a cross-sectional design, phonocardiogram will be recorded at the mitral valve auscultation area of outpatients. The enrolled patients will be checked by echocardiography to confirm the diagnosis of MR or no MR. Echocardiographic parameters will be used as gold standard to assess the severity of MR, classified into four levels: none, mild, moderate and severe. The study consists of two stages. First, an MR-related cardiac sound database will be created on which a DNN-based MR severity classifier will be trained. The automatic MR severity classifier will be integrated with the Smartho-D2 electronic stethoscope. Second, the performance of the developed smart device will be assessed in an independent clinical validation data set. Sensitivity, specificity, precision, accuracy and F1 score of the developed smart MR assessment device will be evaluated. Agreement on the performance of the smart device between cardiologist users and patient users will be inspected. The interpretability of the developed model will also be studied with statistical comparisons of occlusion map-guided variables among the four severity groups. ETHICS AND DISSEMINATION The study protocol was approved by the Medical Ethics Committee of Huzhou Central Hospital, China (registration number: 202302009-01). Informed consent is required from all participants. Dissemination will be through conference presentations and peer-reviewed journals. TRIAL REGISTRATION NUMBER ChiCTR2300069496.
Collapse
Affiliation(s)
- Li Zhang
- Department of Cardiology, Huzhou Central Hospital, The Fifth School of Clinical Medicine of Zhejiang Chinese Medical University, The Affiliated Central Hospital of Huzhou University, Huzhou, Zhejiang, China
| | - Zhenfeng Cheng
- Department of Cardiology, Huzhou Central Hospital, The Fifth School of Clinical Medicine of Zhejiang Chinese Medical University, The Affiliated Central Hospital of Huzhou University, Huzhou, Zhejiang, China
| | - Dongyang Xu
- Center for Intelligent Acoustics and Signal Processing, Huzhou Institute of Zhejiang University, Huzhou, Zhejiang, China
| | - Zhi Wang
- Center for Intelligent Acoustics and Signal Processing, Huzhou Institute of Zhejiang University, Huzhou, Zhejiang, China
- State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou, Zhejiang, China
| | - Shengsheng Cai
- Center for Intelligent Acoustics and Signal Processing, Huzhou Institute of Zhejiang University, Huzhou, Zhejiang, China
- Suzhou Melodicare Medical Technology Co., Ltd, Suzhou, Jiangsu, China
| | - Nan Hu
- School of Electronics and Information Engineering, Soochow University, Suzhou, Jiangsu, China
| | - Jianming Ma
- Administration Office, Huzhou Central Hospital, The Fifth School of Clinical Medicine of Zhejiang Chinese Medical University, The Affiliated Central Hospital of Huzhou University, Huzhou, Zhejiang, China
| | - Xueqin Mei
- Department of Medical Engineering, Huzhou Central Hospital, The Fifth School of Clinical Medicine of Zhejiang Chinese Medical University, The Affiliated Central Hospital of Huzhou University, Huzhou, Zhejiang, China
| |
Collapse
|
2
|
Abbas S, Ojo S, Al Hejaili A, Sampedro GA, Almadhor A, Zaidi MM, Kryvinska N. Artificial intelligence framework for heart disease classification from audio signals. Sci Rep 2024; 14:3123. [PMID: 38326488 PMCID: PMC10850078 DOI: 10.1038/s41598-024-53778-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2023] [Accepted: 02/05/2024] [Indexed: 02/09/2024] Open
Abstract
As cardiovascular disorders are prevalent, there is a growing demand for reliable and precise diagnostic methods within this domain. Audio signal-based heart disease detection is a promising area of research that leverages sound signals generated by the heart to identify and diagnose cardiovascular disorders. Machine learning (ML) and deep learning (DL) techniques are pivotal in classifying and identifying heart disease from audio signals. This study investigates ML and DL techniques to detect heart disease by analyzing noisy sound signals. This study employed two subsets of datasets from the PASCAL CHALLENGE having real heart audios. The research process and visually depict signals using spectrograms and Mel-Frequency Cepstral Coefficients (MFCCs). We employ data augmentation to improve the model's performance by introducing synthetic noise to the heart sound signals. In addition, a feature ensembler is developed to integrate various audio feature extraction techniques. Several machine learning and deep learning classifiers are utilized for heart disease detection. Among the numerous models studied and previous study findings, the multilayer perceptron model performed best, with an accuracy rate of 95.65%. This study demonstrates the potential of this methodology in accurately detecting heart disease from sound signals. These findings present promising opportunities for enhancing medical diagnosis and patient care.
Collapse
Affiliation(s)
- Sidra Abbas
- Department of Computer Science, COMSATS University Islamabad, Islamabad, Pakistan.
| | - Stephen Ojo
- Department of Electrical and Computer Engineering, College of Engineering Anderson, Anderson, SC, 29621, USA
| | - Abdullah Al Hejaili
- Computer Science Department, Faculty of Computers and Information Technology, University of Tabuk, Tabuk, 71491, Saudi Arabia
| | - Gabriel Avelino Sampedro
- Faculty of Information and Communication Studies, University of the Philippines Open University, Los Baños, 4031, Philippines
- Center for Computational Imaging and Visual Innovations, De La Salle University, 2401 Taft Ave., Malate, 1004, Manila, Philippines
| | - Ahmad Almadhor
- Department of Computer Engineering and Networks, College of Computer and Information Sciences, Jouf University, 72388, Sakaka, Saudi Arabia
| | - Monji Mohamed Zaidi
- Department of Electrical Engineering, College of Engineering, King Khalid University, Abha, Saudi Arabia
| | - Natalia Kryvinska
- Information Systems Department, Faculty of Management, Comenius University in Bratislava, Odbojárov 10, 82005, Bratislava 25, Slovakia.
| |
Collapse
|
3
|
Wang J, Zang J, An Q, Wang H, Zhang Z. A pooling convolution model for multi-classification of ECG and PCG signals. Comput Methods Biomech Biomed Engin 2024:1-14. [PMID: 38193152 DOI: 10.1080/10255842.2023.2299697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Accepted: 12/08/2023] [Indexed: 01/10/2024]
Abstract
Electrocardiogram (ECG) and phonocardiogram (PCG) signals are physiological signals generated throughout the cardiac cycle. The application of deep learning techniques to recognize ECG and PCG signals can greatly enhance the efficiency of cardiovascular disease detection. Therefore, we propose a series of straightforward and effective pooling convolutional models for the multi-classification of ECG and PCG signals. Initially, these signals undergo preprocessing. Subsequently, we design various structural blocks, including a stacked block (MCM) comprising convolutional layer and max-pooling layers, along with its variations, as well as a residual block (REC). By adjusting the number of structural blocks, these models can handle ECG and PCG data with different sampling rates. In the final tests, the models utilizing the MCM structural block achieved accuracies of 98.70 and 92.58% on the ECG and PCG fusion datasets, respectively. These accuracies surpass those of all networks utilizing its variations. Moreover, compared to the models employing the REC structural block, the accuracies are improved by 0.02 and 4.30%, respectively. Furthermore, this research has been validated through tests conducted on multiple ECG and PCG datasets, along with comparisons to other published literature. To further validate the generalizability of the model, an additional experiment involving the classification of a synchronized ECG-PCG dataset was conducted. This dataset is divided into seven different levels of fatigue based on the amount of exercise performed by each healthy subject during the testing process. The results indicate that the model using the MCM block also achieved the highest accuracy.
Collapse
Affiliation(s)
- Juliang Wang
- Key Laboratory of Instrumentation Science & Dynamic Measurement of Ministry of Education, North University of China, Taiyuan, China
| | - Junbin Zang
- Key Laboratory of Instrumentation Science & Dynamic Measurement of Ministry of Education, North University of China, Taiyuan, China
| | - Qi An
- Key Laboratory of Instrumentation Science & Dynamic Measurement of Ministry of Education, North University of China, Taiyuan, China
| | - Haoxin Wang
- Key Laboratory of Instrumentation Science & Dynamic Measurement of Ministry of Education, North University of China, Taiyuan, China
| | - Zhidong Zhang
- Key Laboratory of Instrumentation Science & Dynamic Measurement of Ministry of Education, North University of China, Taiyuan, China
| |
Collapse
|
4
|
Li Z, Zhang H. Fusing deep metric learning with KNN for 12-lead multi-labelled ECG classification. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2023.104849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/28/2023]
|
5
|
A Computer-Aided Heart Valve Disease Diagnosis System Based on Machine Learning. JOURNAL OF HEALTHCARE ENGINEERING 2023; 2023:7382316. [PMID: 36726774 PMCID: PMC9886464 DOI: 10.1155/2023/7382316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 01/04/2023] [Accepted: 01/05/2023] [Indexed: 01/24/2023]
Abstract
Cardiac auscultation is a noninvasive, convenient, and low-cost diagnostic method for heart valvular disease, and it can diagnose the abnormality of the heart valve at an early stage. However, the accuracy of auscultation relies on the professionalism of cardiologists. Doctors in remote areas may lack the experience to diagnose correctly. Therefore, it is necessary to design a system to assist with the diagnosis. This study proposed a computer-aided heart valve disease diagnosis system, including a heart sound acquisition module, a trained model for diagnosis, and software, which can diagnose four kinds of heart valve diseases. In this study, a training dataset containing five categories of heart sounds was collected, including normal, mitral stenosis, mitral regurgitation, and aortic stenosis heart sound. A convolutional neural network GoogLeNet and weighted KNN are used to train the models separately. For the model trained by the convolutional neural network, time series heart sound signals are converted into time-frequency scalograms based on continuous wavelet transform to adapt to the architecture of GoogLeNet. For the model trained by weighted KNN, features from the time domain and time-frequency domain are extracted manually. Then feature selection based on the chi-square test is performed to get a better group of features. Moreover, we designed software that lets doctors upload heart sounds, visualize the heart sound waveform, and use the model to get the diagnosis. Model assessments using accuracy, sensitivity, specificity, and F1 score indicators are done on two trained models. The results showed that the model trained by modified GoogLeNet outperformed others, with an overall accuracy of 97.5%. The average accuracy, sensitivity, specificity, and F1 score for diagnosing four kinds of heart valve diseases are 98.75%, 96.88%, 99.22%, and 97.99%, respectively. The computer-aided diagnosis system, with a heart sound acquisition module, a diagnostic model, and software, can visualize the heart sound waveform and show the reference diagnostic results. This can assist in the diagnosis of heart valve diseases, especially in remote areas, which lack skilled doctors.
Collapse
|
6
|
Fuadah YN, Pramudito MA, Lim KM. An Optimal Approach for Heart Sound Classification Using Grid Search in Hyperparameter Optimization of Machine Learning. Bioengineering (Basel) 2022; 10:45. [PMID: 36671616 PMCID: PMC9854602 DOI: 10.3390/bioengineering10010045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 12/13/2022] [Accepted: 12/27/2022] [Indexed: 12/31/2022] Open
Abstract
Heart-sound auscultation is one of the most widely used approaches for detecting cardiovascular disorders. Diagnosing abnormalities of heart sound using a stethoscope depends on the physician's skill and judgment. Several studies have shown promising results in automatically detecting cardiovascular disorders based on heart-sound signals. However, the accuracy performance needs to be enhanced as automated heart-sound classification aids in the early detection and prevention of the dangerous effects of cardiovascular problems. In this study, an optimal heart-sound classification method based on machine learning technologies for cardiovascular disease prediction is performed. It consists of three steps: pre-processing that sets the 5 s duration of the PhysioNet Challenge 2016 and 2022 datasets, feature extraction using Mel frequency cepstrum coefficients (MFCC), and classification using grid search for hyperparameter tuning of several classifier algorithms including k-nearest neighbor (K-NN), random forest (RF), artificial neural network (ANN), and support vector machine (SVM). The five-fold cross-validation was used to evaluate the performance of the proposed method. The best model obtained classification accuracy of 95.78% and 76.31%, which was assessed using PhysioNet Challenge 2016 and 2022, respectively. The findings demonstrate that the suggested approach obtained excellent classification results using PhysioNet Challenge 2016 and showed promising results using PhysioNet Challenge 2022. Therefore, the proposed method has been potentially developed as an additional tool to facilitate the medical practitioner in diagnosing the abnormality of the heart sound.
Collapse
Affiliation(s)
- Yunendah Nur Fuadah
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- School of Electrical Engineering, Telkom University, Bandung 40257, Indonesia
| | - Muhammad Adnan Pramudito
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
| | - Ki Moo Lim
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- Computational Medicine Lab, Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- Meta Heart Co., Ltd., Gumi 39177, Republic of Korea
| |
Collapse
|
7
|
Abbas Q, Hussain A, Baig AR. Automatic Detection and Classification of Cardiovascular Disorders Using Phonocardiogram and Convolutional Vision Transformers. Diagnostics (Basel) 2022; 12:diagnostics12123109. [PMID: 36553116 PMCID: PMC9777096 DOI: 10.3390/diagnostics12123109] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/07/2022] [Accepted: 12/08/2022] [Indexed: 12/14/2022] Open
Abstract
The major cause of death worldwide is due to cardiovascular disorders (CVDs). For a proper diagnosis of CVD disease, an inexpensive solution based on phonocardiogram (PCG) signals is proposed. (1) Background: Currently, a few deep learning (DL)-based CVD systems have been developed to recognize different stages of CVD. However, the accuracy of these systems is not up-to-the-mark, and the methods require high computational power and huge training datasets. (2) Methods: To address these issues, we developed a novel attention-based technique (CVT-Trans) on a convolutional vision transformer to recognize and categorize PCG signals into five classes. The continuous wavelet transform-based spectrogram (CWTS) strategy was used to extract representative features from PCG data. Following that, a new CVT-Trans architecture was created to categorize the CWTS signals into five groups. (3) Results: The dataset derived from our investigation indicated that the CVT-Trans system had an overall average accuracy ACC of 100%, SE of 99.00%, SP of 99.5%, and F1-score of 98%, based on 10-fold cross validation. (4) Conclusions: The CVD-Trans technique outperformed many state-of-the-art methods. The robustness of the constructed model was confirmed by 10-fold cross-validation. Cardiologists can use this CVT-Trans system to help patients with the diagnosis of heart valve problems.
Collapse
Affiliation(s)
- Qaisar Abbas
- College of Computer and Information Sciences, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11432, Saudi Arabia
| | - Ayyaz Hussain
- Department of Computer Science, Quaid-i-Azam University, Islamabad 44000, Pakistan
| | - Abdul Rauf Baig
- College of Computer and Information Sciences, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11432, Saudi Arabia
- Correspondence: ; Tel.: +966-563336816
| |
Collapse
|
8
|
Kuluozturk M, Kobat MA, Barua PD, Dogan S, Tuncer T, Tan RS, Ciaccio EJ, Acharya UR. DKPNet41: Directed knight pattern network-based cough sound classification model for automatic disease diagnosis. Med Eng Phys 2022; 110:103870. [PMID: 35989223 PMCID: PMC9356574 DOI: 10.1016/j.medengphy.2022.103870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 08/03/2022] [Accepted: 08/05/2022] [Indexed: 01/18/2023]
Abstract
PROBLEM Cough-based disease detection is a hot research topic for machine learning, and much research has been published on the automatic detection of Covid-19. However, these studies are useful for the diagnosis of different diseases. AIM In this work, we collected a new and large (n=642 subjects) cough sound dataset comprising four diagnostic categories: 'Covid-19', 'heart failure', 'acute asthma', and 'healthy', and used it to train, validate, and test a novel model designed for automatic detection. METHOD The model consists of four main components: novel feature generation based on a specifically directed knight pattern (DKP), signal decomposition using four pooling methods, feature selection using iterative neighborhood analysis (INCA), and classification using the k-nearest neighbor (kNN) classifier with ten-fold cross-validation. Multilevel multiple pooling decomposition combined with DKP yielded 41 feature vectors (40 extracted plus one original cough sound). From these, the ten best feature vectors were selected. Based on each vector's misclassification rate, redundant feature vectors were eliminated and then merged. The merged vector's most informative features automatically selected using INCA were input to a standard kNN classifier. RESULTS The model, called DKPNet41, attained a high accuracy of 99.39% for cough sound-based multiclass classification of the four categories. CONCLUSIONS The results obtained in the study showed that the DKPNet41 model automatically and efficiently classifies cough sounds for disease diagnosis.
Collapse
Affiliation(s)
- Mutlu Kuluozturk
- Department of Pulmonology, Firat University Hospital, Elazig, Turkey
| | - Mehmet Ali Kobat
- Department of Cardiology, Firat University Hospital, Elazig, Turkey
| | - Prabal Datta Barua
- School of Management & Enterprise, University of Southern Queensland, Australia; Faculty of Engineering and Information Technology, University of Technology Sydney, Australia
| | - Sengul Dogan
- Department of Digital Forensics Engineering, College of Technology, Firat University, Elazig, Turkey.
| | - Turker Tuncer
- Department of Digital Forensics Engineering, College of Technology, Firat University, Elazig, Turkey
| | - Ru-San Tan
- Department of Cardiology, National Heart Centre Singapore, Singapore; Duke-NUS Medical School, Singapore
| | - Edward J Ciaccio
- Department of Medicine, Columbia University Irving Medical Center, USA
| | - U Rajendra Acharya
- Ngee Ann Polytechnic, Department of Electronics and Computer Engineering, 599489, Singapore; Department of Biomedical Engineering, School of Science and Technology, SUSS University, Singapore; Department of Biomedical Informatics and Medical Engineering, Asia University, Taichung, Taiwan
| |
Collapse
|
9
|
Nogueira AFR, Oliveira HS, Machado JJM, Tavares JMRS. Sound Classification and Processing of Urban Environments: A Systematic Literature Review. SENSORS (BASEL, SWITZERLAND) 2022; 22:8608. [PMID: 36433204 PMCID: PMC9698075 DOI: 10.3390/s22228608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 10/31/2022] [Accepted: 11/03/2022] [Indexed: 06/16/2023]
Abstract
Audio recognition can be used in smart cities for security, surveillance, manufacturing, autonomous vehicles, and noise mitigation, just to name a few. However, urban sounds are everyday audio events that occur daily, presenting unstructured characteristics containing different genres of noise and sounds unrelated to the sound event under study, making it a challenging problem. Therefore, the main objective of this literature review is to summarize the most recent works on this subject to understand the current approaches and identify their limitations. Based on the reviewed articles, it can be realized that Deep Learning (DL) architectures, attention mechanisms, data augmentation techniques, and pretraining are the most crucial factors to consider while creating an efficient sound classification model. The best-found results were obtained by Mushtaq and Su, in 2020, using a DenseNet-161 with pretrained weights from ImageNet, and NA-1 and NA-2 as augmentation techniques, which were of 97.98%, 98.52%, and 99.22% for UrbanSound8K, ESC-50, and ESC-10 datasets, respectively. Nonetheless, the use of these models in real-world scenarios has not been properly addressed, so their effectiveness is still questionable in such situations.
Collapse
Affiliation(s)
| | - Hugo S. Oliveira
- Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal
| | - José J. M. Machado
- Departamento de Engenharia Mecânica, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal
| | - João Manuel R. S. Tavares
- Departamento de Engenharia Mecânica, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal
| |
Collapse
|
10
|
PSP-PJMI: An innovative feature representation algorithm for identifying DNA N4-methylcytosine sites. Inf Sci (N Y) 2022. [DOI: 10.1016/j.ins.2022.05.060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
11
|
Automatic detection of heart valve disorders using Teager–Kaiser energy operator, rational-dilation wavelet transform and convolutional neural networks with PCG signals. Artif Intell Rev 2022. [DOI: 10.1007/s10462-022-10184-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
12
|
SABOURI ZAHRA, GHADIMI ABBAS, KIANI-SARKALEH AZADEH, ROUDPOSHTI KAMRADKHOSHHAL. EFFECTIVE FEATURES ANALYSIS IN PARALLEL DIAGNOSIS OF CARDIOVASCULAR DISEASES USING HEART SOUND. J MECH MED BIOL 2022. [DOI: 10.1142/s0219519422500208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Heart sound signal processing is a low-cost, and noninvasive method for the early diagnosis of various types of cardiovascular diseases. In this study, a parallel diagnosing method was proposed to detect various types of heart diseases and healthy heart samples. The proposed system can detect a person who might be simultaneously suffering from two or more heart diseases. Contributing to this line of investigation, effective features were obtained from the morphological and statistical features extracted from five frequency ranges of heart sounds. Applying such features in diagnosing any heart disease acts as a fingerprint specific to that disease. Therefore, the investigation of selected features, especially in each of the frequency ranges of heart sounds and murmurs, provided us with valuable information about the behavior of the diagnostic system in the detection of heart diseases. In addition to using features related to the nature of heart sounds, the proposed method of this study got rid of both the need to apply different filters needed to remove noise and dependence on a specific dataset. With the aid of the effective features in the parallel diagnosis of 15 different types of important and common heart diseases and a healthy class from each other, the diagnostic system of the present study was able to achieve the average accuracy of 97.06%, the average sensitivity of 97.99%, and the average specificity of 96.18% in the shortest possible time. The proposed approach is an important step in the screening and remote monitoring and tracking of disease progression.
Collapse
Affiliation(s)
- ZAHRA SABOURI
- Department of Electrical Engineering, College of Technical and Engineering, West Tehran Branch, Islamic Azad University, Tehran, Iran
| | - ABBAS GHADIMI
- Department of Electrical Engineering, Lahijan Branch, Islamic Azad University, Lahijan, Iran
| | - AZADEH KIANI-SARKALEH
- Department of Electrical Engineering, College of Technical and Engineering, Rasht Branch, Islamic Azad University, Rasht, Iran
| | | |
Collapse
|
13
|
Wang M, Guo B, Hu Y, Zhao Z, Liu C, Tang H. Transfer Learning Models for Detecting Six Categories of Phonocardiogram Recordings. J Cardiovasc Dev Dis 2022; 9:86. [PMID: 35323634 PMCID: PMC8951694 DOI: 10.3390/jcdd9030086] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2022] [Revised: 03/09/2022] [Accepted: 03/14/2022] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND AND AIMS Auscultation is a cheap and fundamental technique for detecting cardiovascular disease effectively. Doctors' abilities in auscultation are varied. Sometimes, there may be cases of misdiagnosis, even when auscultation is performed by an experienced doctor. Hence, it is necessary to propose accurate computational tools to assist auscultation, especially in developing countries. Artificial intelligence technology can be an efficient diagnostic tool for detecting cardiovascular disease. This work proposed an automatic multiple classification method for cardiovascular disease detection by heart sound signals. METHODS AND RESULTS In this work, a 1D heart sound signal is translated into its corresponding 3D spectrogram using continuous wavelet transform (CWT). In total, six classes of heart sound data are used in this experiment. We combine an open database (including five classes of heart sound data: aortic stenosis, mitral regurgitation, mitral stenosis, mitral valve prolapse and normal) with one class (pulmonary hypertension) of heart sound data collected by ourselves to perform the experiment. To make the method robust in a noisy environment, the background deformation technique is used before training. Then, 10 transfer learning networks (GoogleNet, SqueezeNet, DarkNet19, MobileNetv2, Inception-ResNetv2, DenseNet201, Inceptionv3, ResNet101, NasNet-Large, and Xception) are used for comparison. Furthermore, other models (LSTM and CNN) are also compared with our proposed algorithm. The experimental results show that four transfer learning networks (ResNet101, DenseNet201, DarkNet19 and GoogleNet) outperformed their peer models with an accuracy of 0.98 to detect the multiple heart diseases. The performances have been validated both in the original heart sound and the augmented heart sound using 10-fold cross validation. The results of these 10 folds are reported in this research. CONCLUSIONS Our method obtained high classification accuracy even under a noisy background, which suggests that the proposed classification method could be used in auxiliary diagnosis for cardiovascular diseases.
Collapse
Affiliation(s)
- Miao Wang
- School of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China; (M.W.); (B.G.); (Y.H.); (Z.Z.)
| | - Binbin Guo
- School of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China; (M.W.); (B.G.); (Y.H.); (Z.Z.)
| | - Yating Hu
- School of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China; (M.W.); (B.G.); (Y.H.); (Z.Z.)
| | - Zehang Zhao
- School of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China; (M.W.); (B.G.); (Y.H.); (Z.Z.)
| | - Chengyu Liu
- School of Instrument Science and Engineering, Southeast University, Nanjing 214135, China;
| | - Hong Tang
- School of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China; (M.W.); (B.G.); (Y.H.); (Z.Z.)
| |
Collapse
|
14
|
Wang S, Li J, Sun L, Cai J, Wang S, Zeng L, Sun S. Application of machine learning to predict the occurrence of arrhythmia after acute myocardial infarction. BMC Med Inform Decis Mak 2021; 21:301. [PMID: 34724938 PMCID: PMC8560220 DOI: 10.1186/s12911-021-01667-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Accepted: 10/22/2021] [Indexed: 12/23/2022] Open
Abstract
Background Early identification of the occurrence of arrhythmia in patients with acute myocardial infarction plays an essential role in clinical decision-making. The present study attempted to use machine learning (ML) methods to build predictive models of arrhythmia after acute myocardial infarction (AMI). Methods A total of 2084 patients with acute myocardial infarction were enrolled in this study. (All data is available on Github: https://github.com/wangsuhuai/AMI-database1.git). The primary outcome is whether tachyarrhythmia occurred during admission containing atrial arrhythmia, ventricular arrhythmia, and supraventricular tachycardia. All data is randomly divided into a training set (80%) and an internal testing set (20%). Apply three machine learning algorithms: decision tree, random forest (RF), and artificial neural network (ANN) to learn the training set to build a model, then use the testing set to evaluate the prediction performance, and compare it with the model built by the Global Registry of Acute Coronary Events (GRACE) risk variable set. Results Three ML models predict the occurrence of tachyarrhythmias after AMI. After variable selection, the artificial neural network (ANN) model has reached the highest accuracy rate, which is better than the model constructed using the Grace variable set. After applying SHapley Additive exPlanations (SHAP) to make the model interpretable, the most important features are abnormal wall motion, lesion location, bundle branch block, age, and heart rate. Among them, RBBB (odds ratio [OR]: 4.21; 95% confidence interval [CI]: 2.42–7.02), ≥ 2 ventricular walls motion abnormal (OR: 3.26; 95% CI: 2.01–4.36) and right coronary artery occlusion (OR: 3.00; 95% CI: 1.98–4.56) are significant factors related to arrhythmia after AMI. Conclusions We used advanced machine learning methods to build prediction models for tachyarrhythmia after AMI for the first time (especially the ANN model that has the best performance). The current study can supplement the current AMI risk score, provide a reliable evaluation method for the clinic, and broaden the new horizons of ML and clinical research. Trial registration Clinical Trial Registry No.: ChiCTR2100041960. Supplementary Information The online version contains supplementary material available at 10.1186/s12911-021-01667-8.
Collapse
Affiliation(s)
- Suhuai Wang
- Department of Cardiology, The First Affiliated Hospital of Harbin Medical University, 122 Postal Street, Nangang District, Harbin City, Heilongjiang Province, China
| | - Jingjie Li
- Department of Cardiology, The First Affiliated Hospital of Harbin Medical University, 122 Postal Street, Nangang District, Harbin City, Heilongjiang Province, China.
| | - Lin Sun
- Department of Cardiology, The First Affiliated Hospital of Harbin Medical University, 122 Postal Street, Nangang District, Harbin City, Heilongjiang Province, China.
| | - Jianing Cai
- Department of Cardiology, The First Affiliated Hospital of Harbin Medical University, 122 Postal Street, Nangang District, Harbin City, Heilongjiang Province, China
| | - Shihui Wang
- Department of Cardiology, The First Affiliated Hospital of Harbin Medical University, 122 Postal Street, Nangang District, Harbin City, Heilongjiang Province, China
| | - Linwen Zeng
- Department of Cardiology, The First Affiliated Hospital of Harbin Medical University, 122 Postal Street, Nangang District, Harbin City, Heilongjiang Province, China
| | - Shaoqing Sun
- Department of Cardiology, The First Affiliated Hospital of Harbin Medical University, 122 Postal Street, Nangang District, Harbin City, Heilongjiang Province, China
| |
Collapse
|
15
|
Machine Learning and IoT Applied to Cardiovascular Diseases Identification through Heart Sounds: A Literature Review. INFORMATICS 2021. [DOI: 10.3390/informatics8040073] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
This article presents a systematic mapping study dedicated to conduct a literature review on machine learning and IoT applied in the identification of diseases through heart sounds. This research was conducted between January 2010 and July 2021, considering IEEE Xplore, PubMed Central, ACM Digital Library, JMIR—Journal of Medical Internet Research, Springer Library, and Science Direct. The initial search resulted in 4372 papers, and after applying the inclusion and exclusion criteria, 58 papers were selected for full reading to answer the research questions. The main results are: of the 58 articles selected, 46 (79.31%) mention heart rate observation methods with wearable sensors and digital stethoscopes, and 34 (58.62%) mention care with machine learning algorithms. The analysis of the studies based on the bibliometric network generated by the VOSviewer showed in 13 studies (22.41%) a trend related to the use of intelligent services in the prediction of diagnoses related to cardiovascular disorders.
Collapse
|
16
|
Kobat MA, Kivrak T, Barua PD, Tuncer T, Dogan S, Tan RS, Ciaccio EJ, Acharya UR. Automated COVID-19 and Heart Failure Detection Using DNA Pattern Technique with Cough Sounds. Diagnostics (Basel) 2021; 11:1962. [PMID: 34829308 PMCID: PMC8620352 DOI: 10.3390/diagnostics11111962] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 10/17/2021] [Accepted: 10/19/2021] [Indexed: 01/22/2023] Open
Abstract
COVID-19 and heart failure (HF) are common disorders and although they share some similar symptoms, they require different treatments. Accurate diagnosis of these disorders is crucial for disease management, including patient isolation to curb infection spread of COVID-19. In this work, we aim to develop a computer-aided diagnostic system that can accurately differentiate these three classes (normal, COVID-19 and HF) using cough sounds. A novel handcrafted model was used to classify COVID-19 vs. healthy (Case 1), HF vs. healthy (Case 2) and COVID-19 vs. HF vs. healthy (Case 3) automatically using deoxyribonucleic acid (DNA) patterns. The model was developed using the cough sounds collected from 241 COVID-19 patients, 244 HF patients, and 247 healthy subjects using a hand phone. To the best our knowledge, this is the first work to automatically classify healthy subjects, HF and COVID-19 patients using cough sounds signals. Our proposed model comprises a graph-based local feature generator (DNA pattern), an iterative maximum relevance minimum redundancy (ImRMR) iterative feature selector, with classification using the k-nearest neighbor classifier. Our proposed model attained an accuracy of 100.0%, 99.38%, and 99.49% for Case 1, Case 2, and Case 3, respectively. The developed system is completely automated and economical, and can be utilized to accurately detect COVID-19 versus HF using cough sounds.
Collapse
Affiliation(s)
- Mehmet Ali Kobat
- Department of Cardiology, Firat University Hospital, Firat University, Elazig 23119, Turkey; (M.A.K.); (T.K.)
| | - Tarik Kivrak
- Department of Cardiology, Firat University Hospital, Firat University, Elazig 23119, Turkey; (M.A.K.); (T.K.)
| | - Prabal Datta Barua
- School of Management & Enterprise, University of Southern Queensland, Toowoomba, QLD 4350, Australia;
- Faculty of Engineering and Information Technology, University of Technology Sydney, Sydney, NSW 2007, Australia
- Cogninet Brain Team, Cogninet Australia, Sydney, NSW 2010, Australia
| | - Turker Tuncer
- Department of Digital Forensics Engineering, College of Technology, Firat University, Elazig 23119, Turkey; (T.T.); (S.D.)
| | - Sengul Dogan
- Department of Digital Forensics Engineering, College of Technology, Firat University, Elazig 23119, Turkey; (T.T.); (S.D.)
| | - Ru-San Tan
- Department of Cardiology, National Heart Centre Singapore, Singapore 169609, Singapore;
- Department of Cardiology, Duke-NUS Graduate Medical School, Singapore 169857, Singapore
| | - Edward J. Ciaccio
- Department of Medicine, Celiac Disease Center, Columbia University Irving Medical Center, New York, NY 10032, USA;
| | - U. Rajendra Acharya
- Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Singapore 599489, Singapore
- Department of Biomedical Engineering, School of Science and Technology, SUSS University, Clementi 599494, Singapore
- Department of Biomedical Informatics and Medical Engineering, Asia University, Taichung 41354, Taiwan
| |
Collapse
|
17
|
Baygin M, Tuncer T, Dogan S, Tan RS, Acharya UR. Automated arrhythmia detection with homeomorphically irreducible tree technique using more than 10,000 individual subject ECG records. Inf Sci (N Y) 2021. [DOI: 10.1016/j.ins.2021.06.022] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
18
|
Metan J, Prasad A, Ananda Kumar K, Mathapati M, Patil KK. Cardiovascular MRI image analysis by using the bio inspired (sand piper optimized) fully deep convolutional network (Bio-FDCN) architecture for an automated detection of cardiac disorders. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.103002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|