1
|
Fang Y, Zhu D, Wei J, Qian L, Qiu R, Jia T, Huang K, Zhao S, Ouyang J, Li M, Li S, Li Y. Collagen denaturation in post-run Achilles tendons and Achilles tendinopathy: In vivo mechanophysiology and magnetic resonance imaging. SCIENCE ADVANCES 2024; 10:eado2015. [PMID: 39356750 PMCID: PMC11446262 DOI: 10.1126/sciadv.ado2015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Accepted: 08/23/2024] [Indexed: 10/04/2024]
Abstract
Achilles tendinopathy is often attributed to overuse, but its pathophysiology remains poorly understood. Disruption to the molecular structure of collagen is fundamental for the onset and progression of tendinopathy but has mostly been investigated in vitro. Here, we interrogated the in vivo molecular structure changes of collagen in rat Achilles tendons following treadmill running. Unexpectedly, the tendons' collagen molecules were not mechanically unfolded by running but denatured through proteolysis during physiological post-run remodeling. We further revealed that running induces inflammatory gene expressions in Achilles tendons and that long-term running causes prolonged, elevated collagen degradation, leading to the accumulation of denatured collagen and tendinopathy development. For applications, we demonstrated magnetic resonance imaging of collagenase-induced Achilles tendon injury in vivo using a denatured collagen targeting contrast agent. Our findings may help close the knowledge gaps in the mechanobiology and pathogenesis of Achilles tendinopathy and initiate new strategies for its imaging-based diagnosis.
Collapse
Affiliation(s)
- Yijie Fang
- Department of Radiology, Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangdong-Hong Kong-Macao University Joint Laboratory of Interventional Medicine, the Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai, Guangdong 519000, China
| | - Dantian Zhu
- Department of Radiology, Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangdong-Hong Kong-Macao University Joint Laboratory of Interventional Medicine, the Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai, Guangdong 519000, China
| | - Jingyue Wei
- Guangdong Provincial Engineering Research Center of Molecular Imaging, Biobank, Department of Information Technology and Data Center, the Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai, Guangdong 519000, China
| | - Lei Qian
- Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, National Virtual & Reality Experimental Education Center for Medical Morphology, National Experimental Education Demonstration Center for Basic Medical Sciences, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, Guangdong 510000, China
| | - Rongmao Qiu
- Department of Radiology, Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangdong-Hong Kong-Macao University Joint Laboratory of Interventional Medicine, the Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai, Guangdong 519000, China
| | - Taoyu Jia
- Department of Radiology, Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangdong-Hong Kong-Macao University Joint Laboratory of Interventional Medicine, the Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai, Guangdong 519000, China
| | - Kui Huang
- Department of Radiology, Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangdong-Hong Kong-Macao University Joint Laboratory of Interventional Medicine, the Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai, Guangdong 519000, China
- Department of Oral and Maxillofacial Surgery, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan 646000, China
| | - Suwen Zhao
- Department of Radiology, Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangdong-Hong Kong-Macao University Joint Laboratory of Interventional Medicine, the Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai, Guangdong 519000, China
| | - Jun Ouyang
- Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, National Virtual & Reality Experimental Education Center for Medical Morphology, National Experimental Education Demonstration Center for Basic Medical Sciences, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, Guangdong 510000, China
| | - Man Li
- Guangdong Provincial Engineering Research Center of Molecular Imaging, Biobank, Department of Information Technology and Data Center, the Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai, Guangdong 519000, China
| | - Shaolin Li
- Department of Radiology, Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangdong-Hong Kong-Macao University Joint Laboratory of Interventional Medicine, the Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai, Guangdong 519000, China
| | - Yang Li
- Department of Radiology, Guangdong Provincial Engineering Research Center of Molecular Imaging, Guangdong-Hong Kong-Macao University Joint Laboratory of Interventional Medicine, the Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai, Guangdong 519000, China
| |
Collapse
|
2
|
Aggouras AN, Stowe EJ, Mlawer SJ, Connizzo BK. Aged Tendons Exhibit Altered Mechanisms of Strain-Dependent Extracellular Matrix Remodeling. J Biomech Eng 2024; 146:071009. [PMID: 38584416 PMCID: PMC11080950 DOI: 10.1115/1.4065270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 04/02/2024] [Accepted: 04/03/2024] [Indexed: 04/09/2024]
Abstract
Aging is a primary risk factor for degenerative tendon injuries, yet the etiology and progression of this degeneration are poorly understood. While aged tendons have innate cellular differences that support a reduced ability to maintain mechanical tissue homeostasis, the response of aged tendons to altered levels of mechanical loading has not yet been studied. To address this question, we subjected young and aged murine flexor tendon explants to various levels of in vitro tensile strain. We first compared the effect of static and cyclic strain on matrix remodeling in young tendons, finding that cyclic strain is optimal for studying remodeling in vitro. We then investigated the remodeling response of young and aged tendon explants after 7 days of varied mechanical stimulus (stress deprivation, 1%, 3%, 5%, or 7% cyclic strain) via assessment of tissue composition, biosynthetic capacity, and degradation profiles. We hypothesized that aged tendons would show muted adaptive responses to changes in tensile strain and exhibit a shifted mechanical setpoint, at which the remodeling balance is optimal. Interestingly, we found that 1% cyclic strain best maintains native physiology while promoting extracellular matrix (ECM) turnover for both age groups. However, aged tendons display fewer strain-dependent changes, suggesting a reduced ability to adapt to altered levels of mechanical loading. This work has a significant impact on understanding the regulation of tissue homeostasis in aged tendons, which can inform clinical rehabilitation strategies for treating elderly patients.
Collapse
Affiliation(s)
- Anthony N. Aggouras
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02115
- Boston University
| | - Emma J. Stowe
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02115
| | - Samuel J. Mlawer
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02115
- Boston University
| | - Brianne K. Connizzo
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02115
| |
Collapse
|
3
|
Lambrianides Y, Epro G, Arampatzis A, Karamanidis K. Evidence of different sensitivity of muscle and tendon to mechano-metabolic stimuli. Scand J Med Sci Sports 2024; 34:e14638. [PMID: 38671559 DOI: 10.1111/sms.14638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Revised: 03/25/2024] [Accepted: 04/15/2024] [Indexed: 04/28/2024]
Abstract
This study aimed to examine the temporal dynamics of muscle-tendon adaptation and whether differences between their sensitivity to mechano-metabolic stimuli would lead to non-uniform changes within the triceps surae (TS) muscle-tendon unit (MTU). Twelve young adults completed a 12-week training intervention of unilateral isometric cyclic plantarflexion contractions at 80% of maximal voluntary contraction until failure to induce a high TS activity and hence metabolic stress. Each participant trained one limb at a short (plantarflexed position, 115°: PF) and the other at a long (dorsiflexed position, 85°: DF) MTU length to vary the mechanical load. MTU mechanical, morphological, and material properties were assessed biweekly via simultaneous ultrasonography-dynamometry and magnetic resonance imaging. Our hypothesis that tendon would be more sensitive to the operating magnitude of tendon strain but less to metabolic stress exercise was confirmed as tendon stiffness, Young's modulus, and tendon size were only increased in the DF condition following the intervention. The PF leg demonstrated a continuous increment in maximal AT strain (i.e., higher mechanical demand) over time along with lack of adaptation in its biomechanical properties. The premise that skeletal muscle adapts at a higher rate than tendon and does not require high mechanical load to hypertrophy or increase its force potential during exercise was verified as the adaptive changes in morphological and mechanical properties of the muscle did not differ between DF and PF. Such differences in muscle-tendon sensitivity to mechano-metabolic stimuli may temporarily increase MTU imbalances that could have implications for the risk of tendon overuse injury.
Collapse
Affiliation(s)
- Yiannis Lambrianides
- Sport and Exercise Science Research Centre, School of Applied Sciences, London South Bank University, London, UK
| | - Gaspar Epro
- Sport and Exercise Science Research Centre, School of Applied Sciences, London South Bank University, London, UK
| | - Adamantios Arampatzis
- Department of Training and Movement Sciences, Humboldt-Universität zu Berlin, Berlin, Germany
- Berlin School of Movement Science, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Kiros Karamanidis
- Sport and Exercise Science Research Centre, School of Applied Sciences, London South Bank University, London, UK
- Department of Sport Science, Faculty for Mathematics and Natural Sciences, University of Koblenz, Koblenz, Germany
| |
Collapse
|
4
|
Paschall L, Carrozzi S, Tabdanov E, Dhawan A, Szczesny SE. Cyclic loading induces anabolic gene expression in ACLs in a load-dependent and sex-specific manner. J Orthop Res 2024; 42:267-276. [PMID: 37602554 DOI: 10.1002/jor.25677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 06/28/2023] [Accepted: 07/26/2023] [Indexed: 08/22/2023]
Abstract
Anterior cruciate ligament (ACL) injuries are historically thought to be a result of a single acute overload or traumatic event. However, recent studies suggest that ACL failure may be a consequence of fatigue damage. Additionally, the remodeling response of ACLs to fatigue loading is unknown. Therefore, the objective of this study was to investigate the remodeling response of ACLs to cyclic loading. Furthermore, given that women have an increased rate of ACL rupture, we investigated whether this remodeling response is sex specific. ACLs were harvested from male and female New Zealand white rabbits and cyclically loaded in a tensile bioreactor mimicking the full range of physiological loading (2, 4, and 8 MPa). Expression of markers for anabolic and catabolic tissue remodeling, as well as inflammatory cytokines, was quantified using quantitative reverse transcription polymerase chain reaction. We found that the expression of markers for tissue remodeling of the ACL is dependent on the magnitude of loading and is sex specific. Male ACLs activated an anabolic response to cyclic loading at 4 MPa but turned off remodeling at 8 MPa. These data support the hypothesis that noncontact ACL injury may be a consequence of failed tissue remodeling and inadequate repair of microtrauma resulting from elevated loading. Compared to males, female ACLs failed to increase anabolic gene expression with loading and exhibited higher expression of catabolic genes at all loading levels, which may explain the increased rate of ACL tears in women. Together, these data provide insight into load-induced ACL remodeling and potential causes of tissue rupture.
Collapse
Affiliation(s)
- Lauren Paschall
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania, USA
| | - Sabrina Carrozzi
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania, USA
| | - Erdem Tabdanov
- Department of Pharmacology, The Penn State College of Medicine, Hershey, Pennsylvania, USA
| | - Aman Dhawan
- Department of Orthopaedics and Rehabilitation, The Pennsylvania State University, Hershey, Pennsylvania, USA
| | - Spencer E Szczesny
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania, USA
- Department of Orthopaedics and Rehabilitation, The Pennsylvania State University, Hershey, Pennsylvania, USA
| |
Collapse
|
5
|
Aggouras AN, Stowe EJ, Mlawer SJ, Connizzo BK. Aged Tendons Exhibit Altered Mechanisms of Strain-Dependent Extracellular Matrix Remodeling. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.01.26.577397. [PMID: 38352312 PMCID: PMC10862756 DOI: 10.1101/2024.01.26.577397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 02/19/2024]
Abstract
Aging is a primary risk factor for degenerative tendon injuries, yet the etiology and progression of this degeneration is poorly understood. While aged tendons have innate cellular differences that support a reduced ability to maintain mechanical tissue homeostasis, the response of aged tendons to altered levels of mechanical loading has not yet been studied. To address this question, we subjected young and aged murine flexor tendon explants to various levels of in vitro tensile strain. We first compared the effect of static and cyclic strain on matrix remodeling in young tendons, finding that cyclic strain is optimal for studying remodeling in vitro. We then investigated the remodeling response of young and aged tendon explants after 7 days of varied mechanical stimulus (stress-deprivation, 1%, 3%, 5%, or 7% cyclic strain) via assessment of tissue composition, biosynthetic capacity, and degradation profiles. We hypothesized that aged tendons would show muted adaptive responses to changes in tensile strain and exhibit a shifted mechanical setpoint, at which the remodeling balance is optimal. Interestingly, we found 1% cyclic strain best maintains native physiology while promoting ECM turnover for both age groups. However, aged tendons display fewer strain-dependent changes, suggesting a reduced ability to adapt to altered levels of mechanical loading. This work has significant impact in understanding the regulation of tissue homeostasis in aged tendons, which can inform clinical rehabilitation strategies for treating elderly patients.
Collapse
Affiliation(s)
- Anthony N. Aggouras
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts, USA., 44 Cummington Mall, Boston, Massachusetts, USA, 02115
| | - Emma J. Stowe
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts, USA., 44 Cummington Mall, Boston, Massachusetts, USA, 02115
| | - Samuel J. Mlawer
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts, USA., 44 Cummington Mall, Boston, Massachusetts, USA, 02115
| | - Brianne K. Connizzo
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts, USA., 44 Cummington Mall, Boston, Massachusetts, USA, 02115
| |
Collapse
|
6
|
Jerger S, Centner C, Lauber B, Seynnes O, Friedrich T, Lolli D, Gollhofer A, König D. Specific collagen peptides increase adaptions of patellar tendon morphology following 14-weeks of high-load resistance training: A randomized-controlled trial. Eur J Sport Sci 2023; 23:2329-2339. [PMID: 37424319 DOI: 10.1080/17461391.2023.2232758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/11/2023]
Abstract
ABSTRACTThe purpose of this study was to investigate the effect of a supplementation with specific collagen peptides (SCP) combined with resistance training (RT) on changes in structural properties of the patellar tendon. Furthermore, tendon stiffness as well as maximal voluntary knee extension strength and cross-sectional area (CSA) of the rectus femoris muscle were assessed. In a randomized, placebo-controlled study, 50 healthy, moderately active male participants completed a 14-week resistance training program with three weekly sessions (70-85% of 1 repetition maximum [1RM]) for the knee extensors. While the SCP group received 5g of specific collagen peptides daily, the other group received the same amount of a placebo (PLA) supplement. The SCP supplementation led to a significant greater (p < 0.05) increase in patellar tendon CSA compared with the PLA group at 60% and 70% of the patellar tendon length starting from the proximal insertion. Both groups increased tendon stiffness (p < 0.01), muscle CSA (p < 0.05) and muscular strength (p < 0.001) throughout the intervention without significant differences between the groups. The current study shows that in healthy, moderately active men, supplementation of SCP in combination with RT leads to greater increase in patellar tendon CSA than RT alone. Since underlying mechanisms of tendon hypertrophy are currently unknown, further studies should investigate potential mechanisms causing the increased morphology adaptions following SCP supplementation.Trial registration: German Clinical Trials Register identifier: DRKS00029244..
Collapse
Key Words
- 1RM, one repetition maximum
- CSA, cross-sectional area
- ECM, extracellular matrix
- FOV, field of view
- MRI, magnetic resonance imaging
- MVC, maximal voluntary contraction
- Magnetic resonance imaging
- PLA, placebo
- RT, resistance training
- SCP, specific collagen peptides
- SEM, standard error of the mean
- cross sectional area
- supplementation
- tendon properties
- ultrasound
Collapse
Affiliation(s)
- Simon Jerger
- Department of Sport and Sport Science, University of Freiburg, Freiburg im Breisgau, Germany
| | - Christoph Centner
- Department of Sport and Sport Science, University of Freiburg, Freiburg im Breisgau, Germany
- Praxisklinik Rennbahn, Muttenz, Switzerland
| | - Benedikt Lauber
- Department of Sport and Sport Science, University of Freiburg, Freiburg im Breisgau, Germany
- Department of Neurosciences and Movement Sciences, University of Fribourg, Fribourg, Switzerland
| | - Olivier Seynnes
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Till Friedrich
- Department of Sport and Sport Science, University of Freiburg, Freiburg im Breisgau, Germany
| | - David Lolli
- Department of Sport and Sport Science, University of Freiburg, Freiburg im Breisgau, Germany
| | - Albert Gollhofer
- Department of Sport and Sport Science, University of Freiburg, Freiburg im Breisgau, Germany
| | - Daniel König
- Centre of Sport, Science and University Sports, Department of Sports Science, Division for Nutrition, Exercise and Health, University of Vienna, Wien 1150, Austria
- Faculty of Life Sciences, Department of Nutritional Sciences, Division for Nutrition, Exercise and Health, University of Vienna, Wien 1090, Austria
| |
Collapse
|
7
|
Williamson PM, Yeritsyan D, Peacock T, Chainani P, Momenzadeh K, Asciutto D, Pathirana P, Avakian C, Stewart I, Kheir N, Abbasian M, DeAngelis JP, Ramappa AJ, Nazarian A. A passive ankle dorsiflexion testing system to assess mechanobiological and structural response to cyclic loading in rat Achilles tendon. J Biomech 2023; 156:111664. [PMID: 37302164 PMCID: PMC10439675 DOI: 10.1016/j.jbiomech.2023.111664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 04/16/2023] [Accepted: 05/23/2023] [Indexed: 06/13/2023]
Abstract
Tendinopathy is thought to be caused by repeated overload of the tendon with insufficient recovery time, leading to an inadequate healing response and incomplete recovery of preinjury material strength and function. The etiology of tendinopathy induced by mechanical load is being explored with a variety of mechanical load scenarios in small animals. This study establishes a testing system that applies passive ankle dorsiflexion to a rat hindlimb, estimates the force applied to the tendon during cyclic loading and enables the assessment of subsequent structural and biological changes. We demonstrated that the system had no drift in the applied angle, and the registered maximum angle and torque inputs and outputs were consistent between tests. We showed that cyclic loading decreased hysteresis and loading and unloading moduli with increasing cycles applied to the tendon. Histology showed gross changes to tendon structure. This work establishes a system for passively loading the rat Achilles tendon in-vivo in a physiological manner, facilitating future studies that will explore how mechanics, structure, and biology are altered by mechanical repetitive loading.
Collapse
Affiliation(s)
- Patrick M Williamson
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA; Boston University, Mechanical Engineering Department, Boston, MA
| | - Diana Yeritsyan
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Thomas Peacock
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Pooja Chainani
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA; Boston University, Mechanical Engineering Department, Boston, MA
| | - Kaveh Momenzadeh
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Dominic Asciutto
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Priyan Pathirana
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Christina Avakian
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Isabella Stewart
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Nadim Kheir
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Mohammadreza Abbasian
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Joseph P DeAngelis
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA; Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Arun J Ramappa
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA; Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Ara Nazarian
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA; Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA; Department of Orthopaedic Surgery, Yerevan State Medical University. Yerevan, Armenia.
| |
Collapse
|
8
|
Klich S, Madeleine P, Ficek K, Sommer K, Fernández-de-Las-Peñas C, Michener LA, Kawczyński A. Functional and morphological changes in shoulder girdle muscles after repeated climbing exercise. Res Sports Med 2023; 31:787-801. [PMID: 35179412 DOI: 10.1080/15438627.2022.2042295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Accepted: 02/09/2022] [Indexed: 10/19/2022]
Abstract
This study aimed to investigate the acute effect of repeated climbing actions on functional and morphological measures of the shoulder girdle. Fifteen male indoor climbers participated in this study. All the climbers declared route level 6a+, as the best climbing grade (French climbing grade scale). Functional (range of motion - ROM and muscle strength), and morphological measurements (muscle/tendon stiffness and thickness) after a repeated climbing exercise protocol were analysed. The ROM and muscle strength showed significant decreases from baseline to Immediate-Post (IA) as well as significant increases from IA to 1 h-Post for all movements (p ≤ .001 for all). Muscle stiffness showed significant increases from baseline to IA after as well as significant decreases from IA to 1 h-Post for all muscles (p ≤ .001 for all). However, the thickness showed significant increases from baseline to IA for supraspinatus tendon and muscle thickness and occupation ratio (p ≤ .001 for all), while a significant decrease was observed in acromiohumeral distance (p ≤ .001). Significant decreases from IA to 1 h-Post were found for muscles/tendons and occupation ratio (p ≤ .001 for all), while a significant increase for AHD (p ≤ .001). Our data demonstrated acute alterations in tendon thickness due to acute signs of implement symptom in climbers.
Collapse
Affiliation(s)
- Sebastian Klich
- Department of Paralympic Sport, Wrocław University of Health and Sport Science, Wrocław, Poland
| | - Pascal Madeleine
- Department of Health Science and Technology, Sport Sciences - Performance and Technology, Aalborg University, Aalborg, Denmark
| | - Krzysztof Ficek
- Department of Physiotherapy, Academy of Physical Education in Katowice, Katowice, Poland
- Galen Orthopedic Center, Bieruń, Poland
| | - Klaudia Sommer
- Wrocław University of Health and Sport Science, Wrocław, Poland
| | - Cesar Fernández-de-Las-Peñas
- Department of Physical Therapy, Occupational Therapy, Rehabilitation and Physical Medicine, Universidad Rey Juan Carlos, Alcorcón, Spain
- Cátedra Institucional En Docencia, Clínica E Investigación En Fisioterapia: Terapia Manual, Punción Seca Y Ejercicio Terapéutico, Universidad Rey Juan Carlos, Alcorcón, Spain
| | - Lori A Michener
- Clinical Biomechanics Orthopedic and Sports Outcomes ResearchLaboratory (COOR Lab), Division of Biokinesiology and Physical Therapy, University of Southern California, Los Angeles, CA, USA
| | - Adam Kawczyński
- Department of Biomechanics and Sport Engineering, Gdansk University of Physical Education and Sport, Gdansk, Poland
| |
Collapse
|
9
|
Yagi I, Koike K, Kato E, Uchida S, Kakihana T, Sunakawa H. Correlation between Mechanical Properties and Collagen Degeneration in Fibrous Tissue. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38083610 DOI: 10.1109/embc40787.2023.10341084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Fibrosis is a disease that causes abnormal accumulation of collagen and other extracellular matrix components. It can lead to organ failure and is responsible for one-third of all deaths worldwide. However, there is no cure for this disease, and the development of minimally invasive therapies is urgently needed. We have previously reported techniques for adjusting the shape and flexibility of fibrous tissue by traction while denaturing it with heat. However, studies comparing heat and traction on fibrous tissue are limited, so this paper examined that. Applying heat and traction to bovine Achilles tendon tissue has been shown to cause the denaturation of collagen molecules to accumulate in the tissue in response to these loads. Heat-induced collagen denaturation was nondirectional and omnidirectional, whereas mechanical stress-induced collagen denaturation was concentrated in the direction of traction. When both heat and traction were applied, collagen denaturation increased more than under a single load, indicating a synergistic effect.
Collapse
|
10
|
Ganji E, Lamia SN, Stepanovich M, Whyte N, Goulet RW, Abraham AC, Killian ML. Optogenetic-induced muscle loading leads to mechanical adaptation of the Achilles tendon enthesis in mice. SCIENCE ADVANCES 2023; 9:eadf4683. [PMID: 37352350 PMCID: PMC10289645 DOI: 10.1126/sciadv.adf4683] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 05/17/2023] [Indexed: 06/25/2023]
Abstract
Skeletal shape depends on the transmission of contractile muscle forces from tendon to bone across the enthesis. Loss of muscle loading impairs enthesis development, yet little is known if and how the postnatal enthesis adapts to increased loading. Here, we studied adaptations in enthesis structure and function in response to increased loading, using optogenetically induced muscle contraction in young (i.e., growth) and adult (i.e., mature) mice. Daily bouts of unilateral optogenetic loading in young mice led to radial calcaneal expansion and warping. This also led to a weaker enthesis with increased collagen damage in young tendon and enthisis, with little change in adult mice. We then used RNA sequencing to identify the pathways associated with increased mechanical loading during growth. In tendon, we found enrichment of glycolysis, focal adhesion, and cell-matrix interactions. In bone, we found enrichment of inflammation and cell cycle. Together, we demonstrate the utility of optogenetic-induced muscle contraction to elicit in vivo adaptation of the enthesis.
Collapse
Affiliation(s)
- Elahe Ganji
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Ave., Urbana, IL 61801, USA
- Department of Biomedical Engineering, University of Delaware, 540 S. College Ave., Newark, DE 19713, USA
| | - Syeda N. Lamia
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
- Department of Mechanical Engineering, University of Michigan, 2350 Hayward St., Ann Arbor, MI 48109, USA
| | - Matthew Stepanovich
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
| | - Noelle Whyte
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
| | - Robert W. Goulet
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
| | - Adam C. Abraham
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
| | - Megan L. Killian
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
- Department of Biomedical Engineering, University of Delaware, 540 S. College Ave., Newark, DE 19713, USA
| |
Collapse
|
11
|
Loflin BE, Ahn T, Colglazier KA, Banaszak Holl MM, Ashton-Miller JA, Wojtys EM, Schlecht SH. An Adolescent Murine In Vivo Anterior Cruciate Ligament Overuse Injury Model. Am J Sports Med 2023; 51:1721-1732. [PMID: 37092727 PMCID: PMC10348391 DOI: 10.1177/03635465231165753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/25/2023]
Abstract
BACKGROUND Overuse ligament and tendon injuries are prevalent among recreational and competitive adolescent athletes. In vitro studies of the ligament and tendon suggest that mechanical overuse musculoskeletal injuries begin with collagen triple-helix unraveling, leading to collagen laxity and matrix damage. However, there are little in vivo data concerning this mechanism or the physiomechanical response to collagen disruption, particularly regarding the anterior cruciate ligament (ACL). PURPOSE To develop and validate a novel in vivo animal model for investigating the physiomechanical response to ACL collagen matrix damage accumulation and propagation in the ACL midsubstance, fibrocartilaginous entheses, and subchondral bone. STUDY DESIGN Controlled laboratory study. METHODS C57BL/6J adolescent inbred mice underwent 3 moderate to strenuous ACL fatigue loading sessions with a 72-hour recovery between sessions. Before each session, randomly selected subsets of mice (n = 12) were euthanized for quantifying collagen matrix damage (percent collagen unraveling) and ACL mechanics (strength and stiffness). This enabled the quasi-longitudinal assessment of collagen matrix damage accrual and whole tissue mechanical property changes across fatigue sessions. Additionally, all cyclic loading data were quantified to evaluate changes in knee mechanics (stiffness and hysteresis) across fatigue sessions. RESULTS Moderate to strenuous fatigue loading across 3 sessions led to a 24% weaker (P = .07) and 35% less stiff (P < .01) ACL compared with nonloaded controls. The unraveled collagen densities within the fatigued ACL and entheseal matrices after the second and third sessions were 38% (P < .01) and 15% (P = .02) higher compared with the nonloaded controls. CONCLUSION This study confirmed the hypothesis that in vivo ACL collagen matrix damage increases with tissue fatigue sessions, adversely impacting ACL mechanical properties. Moreover, the in vivo ACL findings were consistent with in vitro overloading research in humans. CLINICAL RELEVANCE The outcomes from this study support the use of this model for investigating ACL overuse injuries.
Collapse
Affiliation(s)
- Benjamin E. Loflin
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Taeyong Ahn
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Kaitlyn A. Colglazier
- Purdue School of Engineering and Technology, Purdue University–Indianapolis, Indianapolis, Indiana, USA
| | - Mark M. Banaszak Holl
- Department of Orthopaedic Surgery, Heersink School of Medicine, University of Alabama–Birmingham, Birmingham, Alabama, USA
| | | | - Edward M. Wojtys
- Department of Orthopaedic Surgery, University of Michigan School of Medicine, Ann Arbor, Michigan, USA
| | - Stephen H. Schlecht
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana, USA
- Purdue School of Engineering and Technology, Purdue University–Indianapolis, Indianapolis, Indiana, USA
- Department of Anatomy, Cell Biology and Physiology, Indiana University School of Medicine, Indianapolis, Indiana, USA
| |
Collapse
|
12
|
Ganji E, Lamia SN, Stepanovich M, Whyte N, Abraham AC, Killian ML. Optogenetic-Induced Muscle Loading Leads to Mechanical Adaptation of the Achilles Tendon Enthesis in Mice. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.04.11.536376. [PMID: 37090593 PMCID: PMC10120626 DOI: 10.1101/2023.04.11.536376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/25/2023]
Abstract
The growth of the skeleton depends on the transmission of contractile muscle forces from tendon to bone across the extracellular matrix-rich enthesis. Loss of muscle loading leads to significant impairments in enthesis development. However, little is known about how the enthesis responds to increased loading during postnatal growth. To study the cellular and matrix adaptations of the enthesis in response to increased muscle loading, we used optogenetics to induce skeletal muscle contraction and unilaterally load the Achilles tendon and enthesis in young (i.e., during growth) and adult (i.e., mature) mice. In young mice, daily bouts of unilateral optogenetic loading led to expansion of the calcaneal apophysis and growth plate, as well as increased vascularization of the normally avascular enthesis. Daily loading bouts, delivered for 3 weeks, also led to a mechanically weaker enthesis with increased molecular-level accumulation of collagen damage in young mice. However, adult mice did not exhibit impaired mechanical properties or noticeable structural adaptations to the enthesis. We then focused on the transcriptional response of the young tendon and bone following optogenetic-induced loading. After 1 or 2 weeks of loading, we identified, in tendon, transcriptional activation of canonical pathways related to glucose metabolism (glycolysis) and inhibited pathways associated with cytoskeletal remodeling (e.g., RHOA and CREB signaling). In bone, we identified activation of inflammatory signaling (e.g., NFkB and STAT3 signaling) and inhibition of ERK/MAPK and PTEN signaling. Thus, we have demonstrated the utility of optogenetic-induced skeletal muscle contraction to elicit structural, functional, and molecular adaptation of the enthesis in vivo especially during growth.
Collapse
Affiliation(s)
- Elahe Ganji
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, Michigan, 48109
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Ave., Urbana, Illinois, 61801
| | - Syeda N Lamia
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, Michigan, 48109
- Department of Mechanical Engineering, University of Michigan, 2350 Hayward St., Ann Arbor, Michigan, 48109
| | - Matthew Stepanovich
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, Michigan, 48109
| | - Noelle Whyte
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, Michigan, 48109
| | - Adam C Abraham
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, Michigan, 48109
| | - Megan L Killian
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, Michigan, 48109
- Department of Biomedical Engineering, University of Delaware, 540 S. College Ave., Newark, Delaware, 19713
| |
Collapse
|
13
|
Muljadi PM, Andarawis-Puri N. Glycosaminoglycans modulate microscale mechanics and viscoelasticity in fatigue injured tendons. J Biomech 2023; 152:111584. [PMID: 37080079 DOI: 10.1016/j.jbiomech.2023.111584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Revised: 03/08/2023] [Accepted: 04/05/2023] [Indexed: 04/22/2023]
Abstract
Tendinopathies are common injuries that typically occur from overuse and fatigue. Treatments target late-stage symptoms with limited success, leading to high rates of reinjury. Early intervention could halt tendinopathy progression to rupture but requires a better understanding of the biomechanical environment associated with early-stage disease. While fatigue injured tendons are further damaged by exercise that is initiated immediately after onset of injury, exercise that is initiated after a brief delay promotes repair. Similar macroscale mechanical properties and collagen damage throughout this delay period suggests that microscale, non-collagenous matrix changes after fatigue injury modulate tendon mechanotransduction and shifts the exercise response from detrimental to reparative. Glycosaminoglycans (GAGs) and proteoglycans (PGs) are increased during chronic tendinopathy, but their role in early-stage disease is unknown. We hypothesized that increased GAGs from fatigue injury modulate viscoelasticity and microscale strains to enable repair from exercise. Various GAG types were increased in the weeks after onset of fatigue injury in the extracellular and pericellular matrices of rat patellar tendons. Enzymatic removal of GAGs from these fatigued tendons increased microscale shear strain, suggesting that GAGs modulate the cell microenvironment after fatigue injury. GAG removal decreased dynamic modulus in the toe region and decreased loss tangent in the linear region of the stress-strain curve in fatigued tendons, suggesting the GAG increase modulates tendon multiscale mechanics and viscoelasticity during fiber uncrimping and fibril sliding and strain transfer. GAGs may influence repair in response to exercise and could serve as a therapeutic target for tendinopathy.
Collapse
Affiliation(s)
- Patrick M Muljadi
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, USA
| | - Nelly Andarawis-Puri
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, USA; Hospital for Special Surgery, New York, NY, USA.
| |
Collapse
|
14
|
Pedaprolu K, Szczesny SE. Mouse Achilles tendons exhibit collagen disorganization but minimal collagen denaturation during cyclic loading to failure. J Biomech 2023; 151:111545. [PMID: 36944295 PMCID: PMC10069227 DOI: 10.1016/j.jbiomech.2023.111545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 02/21/2023] [Accepted: 03/08/2023] [Indexed: 03/14/2023]
Abstract
While overuse is a prominent risk factor for tendinopathy, the fatigue-induced structural damage responsible for initiating tendon degeneration remains unclear. Denaturation of collagen molecules and collagen fiber disorganization have been observed within certain tendons in response to fatigue loading. However, no studies have investigated whether these forms of tissue damage occur in Achilles tendons, which commonly exhibit tendinopathy. Therefore, the objective of this study was to determine whether mouse Achilles tendons undergo collagen denaturation and collagen fiber disorganization when cyclically loaded to failure. Consistent with previous testing of other energy-storing tendons, we found that cyclic loading of mouse Achilles tendons produced collagen disorganization but minimal collagen denaturation. To determine whether the lack of collagen denaturation is unique to mouse Achilles tendons, we monotonically loaded the Achilles and other mouse tendons to failure. We found that the patellar tendon was also resistant to collagen denaturation, but the flexor digitorum longus (FDL) tendon and tail tendon fascicles were not. Furthermore, the Achilles and patellar tendons had a lower tensile strength and modulus. While this may be due to differences in tissue structure, it is likely that the lack of collagen denaturation during monotonic loading in both the Achilles and patellar tendons was due to failure near their bony insertions, which were absent in the FDL and tail tendons. These findings suggest that mouse Achilles tendons are resistant to collagen denaturation in situ and that Achilles tendon degeneration may not be initiated by mechanically-induced damage to collagen molecules.
Collapse
Affiliation(s)
- Krishna Pedaprolu
- Department of Biomedical Engineering, Pennsylvania State University, University Park, PA, United States
| | - Spencer E Szczesny
- Department of Biomedical Engineering, Pennsylvania State University, University Park, PA, United States; Department of Orthopaedics and Rehabilitation, Pennsylvania State University, Hershey, PA, United States.
| |
Collapse
|
15
|
Gains CC, Giannapoulos A, Zamboulis DE, Lopez-Tremoleda J, Screen HRC. Development and application of a novel in vivo overload model of the Achilles tendon in rat. J Biomech 2023; 151:111546. [PMID: 36958089 DOI: 10.1016/j.jbiomech.2023.111546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 03/03/2023] [Accepted: 03/09/2023] [Indexed: 03/17/2023]
Abstract
Repetitive overload is a primary factor in tendon injury, causing progressive accumulation of matrix damage concurrent with a cellular response. However, it remains unclear how these events occur at the initial stages of the disease, making it difficult to identify appropriate treatment approaches. Here, we describe the development of a new model to cyclically load the Achilles tendon (AT) of rats in vivo and investigate the initial structural and cellular responses. The model utilizes controlled dorsiflexion of the ankle joint applied near maximal dorsiflexion, for 10,000 cycles at 3 Hz. Animals were subjected to a single bout of in vivo loading under anaesthesia, and either culled immediately (without recovery from anaesthesia), or 48 h or 4-weeks post-loading. Macro strains were assessed in cadavers, whilst tendon specific microdamage was assessed through collagen-hybridizing peptide (CHP) immunohistochemistry which highlighted a significant rise in CHP staining in loaded ATs compared to contralateral controls, indicating an accumulation of overload-induced damage. Staining for pro-inflammatory mediators (IL-6 and COX-2) and matrix degradation markers (MMP-3 and -13) also suggests an initial cellular response to overload. Model validation confirmed our approach was able to explore early overload-induced damage within the AT, with microdamage present and no evidence of broader musculoskeletal damage. The new model may be implemented to map the progression of tendinopathy in the AT, and thus study potential therapeutic interventions.
Collapse
Affiliation(s)
- Connor Charles Gains
- School of Engineering and Materials Science (SEMS), Queen Mary University of London, Mile End Road, London E1 4NS, United Kingdom.
| | - Antonios Giannapoulos
- School of Engineering and Materials Science (SEMS), Queen Mary University of London, Mile End Road, London E1 4NS, United Kingdom
| | - Danae Emilie Zamboulis
- School of Engineering and Materials Science (SEMS), Queen Mary University of London, Mile End Road, London E1 4NS, United Kingdom
| | - Jordi Lopez-Tremoleda
- Blizard Institute, Faculty of Medicine and Dentistry, Queen Mary University of London, Mile End Road, London E1 4NS, United Kingdom
| | - Hazel R C Screen
- School of Engineering and Materials Science (SEMS), Queen Mary University of London, Mile End Road, London E1 4NS, United Kingdom
| |
Collapse
|
16
|
Review of human supraspinatus tendon mechanics. Part I: fatigue damage accumulation and failure. J Shoulder Elbow Surg 2022; 31:2671-2677. [PMID: 35931330 DOI: 10.1016/j.jse.2022.06.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 06/10/2022] [Accepted: 06/27/2022] [Indexed: 02/01/2023]
Abstract
Repetitive stress injuries to the rotator cuff, and particularly the supraspinatus tendon (SST), are highly prevalent and debilitating. These injuries typically occur through the application of cyclic load below the threshold necessary to cause acute tears, leading to accumulation of incremental damage that exceeds the body's ability to heal, resulting in decreased mechanical strength and increased risk of frank rupture at lower loads. Consistent progression of fatigue damage across multiple model systems suggests a generalized tendon response to overuse. This finding may allow for interventions before gross injury of the SST occurs. Further research into the human SST response to fatigue loading is necessary to characterize the fatigue life of the tendon, which will help determine the frequency, duration, and magnitude of load spectra the SST may experience before injury. Future studies may allow in vivo SST strain analysis during specific activities, generation of a human SST stress-cycle curve, and characterization of damage and repair related to repetitive tasks.
Collapse
|
17
|
Ortega-Castillo M, Cuesta-Vargas A, Luque-Teba A, Trinidad-Fernández M. The role of progressive, therapeutic exercise in the management of upper limb tendinopathies: A systematic review and meta-analysis. Musculoskelet Sci Pract 2022; 62:102645. [PMID: 35964498 DOI: 10.1016/j.msksp.2022.102645] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 06/26/2022] [Accepted: 08/04/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND Among upper limb tendinopathies, rotator cuff-related shoulder pain and lateral elbow tendinopathy are the most representative disorders. Therapeutic exercise arises as an effective approach, but there is no consensus about the optimal progression criteria. OBJECTIVE To compare progression criteria and effectiveness of isolated, progressive exercises in the management of upper limb tendinopathies. Additionally, to perform a meta-analysis of pain/function for the selected programs. DESIGN Systematic Review and Meta-Analysis. METHOD Database search of randomized-controlled-trials including progressive exercise was conducted in PubMed and Scopus until October 2020. Meta-analysis' inclusion criteria were: no data duplicity; 3-months follow-up; comparison between any type of progressive exercise program. Risk of bias was assessed with PEDro score, and level of evidence followed GRADE guidelines. Effect size was calculated with Cohen's d. RESULTS Eleven studies were included. GRADE revealed low-quality evidence for meta-analysis of pain during activity (d = 0.29) and function (d = 0.33) at 3 months. Progression criteria were categorised into two divisions, being pain the central concept. Pain (rest/activity/night) and function improved significantly within-group, but between-group changes were heterogeneous. Meta-analysis regarding pain showed good homogeneity with significant, moderate effects (I2 = 20%; p = 0.005; mean d = 0.29); function yielded important heterogeneity with non-significant, moderate effects (I2 = 81%; p = 0.17; mean d = 0.33). CONCLUSIONS Pain was the most frequent benchmark when modulating and progressing the exercises, although other criteria were found such as fatigue or self-perceived ability. Progressive exercise seems effective to manage upper limb tendinopathies, but the superiority of a progression criterion against others remains unclear. Low-quality evidence supported progressive exercise with eccentric components in adding a significant and moderate effect on pain/function at short-term.
Collapse
Affiliation(s)
- Miguel Ortega-Castillo
- Department of Physiotherapy, Clinimetric Group F-14, Biomedical Research Institute of Malaga (IBIMA), University of Malaga, 29010, Málaga, Spain.
| | - Antonio Cuesta-Vargas
- Department of Physiotherapy, Clinimetric Group F-14, Biomedical Research Institute of Malaga (IBIMA), University of Malaga, 29010, Málaga, Spain; School of Clinical Science, Queensland University Technology, Brisbane, 4072, Australia. https://twitter.com/aicuesta
| | - Antonio Luque-Teba
- Higher Technical School of Informatics Engineering, University of Sevilla, 41092, Sevilla, Spain.
| | - Manuel Trinidad-Fernández
- Department of Physiotherapy, Clinimetric Group F-14, Biomedical Research Institute of Malaga (IBIMA), University of Malaga, 29010, Málaga, Spain; Rehabilitation Sciences Research Department, Vrije Universiteit Brussel, 1090, Brussel, Belgium.
| |
Collapse
|
18
|
Fontenele FF, Bouklas N. Understanding the inelastic response of collagen fibrils: A viscoelastic-plastic constitutive model. Acta Biomater 2022; 163:78-90. [PMID: 35835288 DOI: 10.1016/j.actbio.2022.07.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 07/01/2022] [Accepted: 07/05/2022] [Indexed: 11/01/2022]
Abstract
Collagen fibrils, which are the lowest level fibrillar unit of organization of collagen, are thus of primary interest towards understanding the mechanical behavior of load-bearing soft tissues. The deformation of collagen fibrils shows unique mechanical features; namely, their high energy dissipation is even superior compared to most engineering materials. Additionally, there are indications that cyclic loading can further improve the toughness of collagen fibrils. Recent experiments from Liu at al. (2018) focused on the response of type I collagen fibrils to uniaxial cyclic loading, revealing some interesting results regarding their rate-dependent and inelastic response. In this work, we aim to develop a model that allows interpreting the complex nonlinear and inelastic response of collagen fibrils under cyclic loading. We propose a constitutive model that accounts for viscoelastic deformations through a decoupled strain-energy density function (into an elastic and a viscous parts), and for plastic deformations through plastic evolution laws. The stress-stretch response results obtained using this constitutive law showed good agreement with experimental data over complex loading paths. Ultimately we use the model to gain more insights on how cyclic loading and rate effects control the interplay between viscoelastic and plastic deformation in collagen fibrils, and to extrapolate the results from experimental data, analyzing how complex cyclic load influences energy dissipation and deformation mechanisms. STATEMENT OF SIGNIFICANCE: In this work, we develop a viscoelastic-plastic constitutive model for collagen fibrils with the aim of analyzing the effects of inelasticity and energy dissipation in this material, and more specifically the competition between viscoelasticity and plasticity in the context of cyclic loading and overload. Experimental and theoretical approaches so far have not fully clarified the interplay between viscous and plastic deformations during cyclic loading of collagen fibrils. Here, we aim to interpret the complex nonlinear response of collagen fibrils and, ultimately, suggest predictive capabilities that can inform tissue-level response and injury. To validate our model, we compare our results against the stress-stretch data obtained from experiments of cyclic loaded single fibrils performed by Liu et al. (2018).
Collapse
Affiliation(s)
- Fernanda F Fontenele
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, NY 14853, USA
| | - Nikolaos Bouklas
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, NY 14853, USA.
| |
Collapse
|
19
|
Chen W, Zhou Q. Opposite Effect of Cyclic Loading on the Material Properties of Medial Collateral Ligament at Different Temperatures: An Animal Study. Front Bioeng Biotechnol 2022; 10:925033. [PMID: 35774057 PMCID: PMC9237215 DOI: 10.3389/fbioe.2022.925033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Accepted: 05/23/2022] [Indexed: 11/13/2022] Open
Abstract
In traffic accidents, the medial collateral ligament (MCL) injury of the knee joint of pedestrians is common. Biofidelic material is important to realize MCL's native biomechanics in simulations to clarify the injury mechanisms of pedestrians. Pedestrians' MCLs usually experience cyclic loading at the intra-articular temperature of the knee joint before accidents. Temperature influences the material behaviors of ligaments. However, the mechanical properties of ligaments under cyclic loading have been widely evaluated only at room temperature rather than physiological temperature. Therefore, this study aimed to determine whether the difference between room and intra-articular temperatures influences the effect of cyclic loading on the mechanical properties of MCL. We measured the tensile properties of 34 porcine MCLs at room temperature (21-23°C) and intra-articular temperature (35-37°C), with either 10 cycles or 240 cycles of cyclic loading, a total of four different conditions. The structural responses and geometric data were recorded. After 240 cycles of cyclic loading, stiffness increased by 29.0% (p < 0.01) at room temperature and decreased by 11.5% (p = 0.106) at intra-articular temperature. Material properties were further compared because the geometric differences between samples were inevitable. At room temperature, after 240 cycles of cyclic loading, elastic modulus increased by 29.6% (p < 0.001), and failure strain decreased by 20.4% (p < 0.05). By contrast, at intra-articular temperature, after 240 cycles of cyclic loading, modulus decreased by 27.4% (p < 0.001), and failure strain increased by 17.5% (p = 0.193), insignificant though. In addition, there were no significant differences between the four groups in other structural or material properties. The results showed that temperature reversed the effect of cyclic loading on the mechanical properties of MCL, which may be caused by the high strength and thermally stable crosslinks of MCL. Therefore, for improving the fidelity of knee joint simulations and elucidating the injury mechanism of pedestrians, it is better to measure the mechanical properties of MCL at intra-articular temperature rather than room temperature.
Collapse
Affiliation(s)
| | - Qing Zhou
- State Key Laboratory of Automotive Safety and Energy, School of Vehicle and Mobility, Tsinghua University, Beijing, China
| |
Collapse
|
20
|
Eisner LE, Rosario R, Andarawis-Puri N, Arruda EM. The Role of the Non-Collagenous Extracellular Matrix in Tendon and Ligament Mechanical Behavior: A Review. J Biomech Eng 2022; 144:1128818. [PMID: 34802057 PMCID: PMC8719050 DOI: 10.1115/1.4053086] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Indexed: 12/26/2022]
Abstract
Tendon is a connective tissue that transmits loads from muscle to bone, while ligament is a similar tissue that stabilizes joint articulation by connecting bone to bone. The 70-90% of tendon and ligament's extracellular matrix (ECM) is composed of a hierarchical collagen structure that provides resistance to deformation primarily in the fiber direction, and the remaining fraction consists of a variety of non-collagenous proteins, proteoglycans, and glycosaminoglycans (GAGs) whose mechanical roles are not well characterized. ECM constituents such as elastin, the proteoglycans decorin, biglycan, lumican, fibromodulin, lubricin, and aggrecan and their associated GAGs, and cartilage oligomeric matrix protein (COMP) have been suggested to contribute to tendon and ligament's characteristic quasi-static and viscoelastic mechanical behavior in tension, shear, and compression. The purpose of this review is to summarize existing literature regarding the contribution of the non-collagenous ECM to tendon and ligament mechanics, and to highlight key gaps in knowledge that future studies may address. Using insights from theoretical mechanics and biology, we discuss the role of the non-collagenous ECM in quasi-static and viscoelastic tensile, compressive, and shear behavior in the fiber direction and orthogonal to the fiber direction. We also address the efficacy of tools that are commonly used to assess these relationships, including enzymatic degradation, mouse knockout models, and computational models. Further work in this field will foster a better understanding of tendon and ligament damage and healing as well as inform strategies for tissue repair and regeneration.
Collapse
Affiliation(s)
- Lainie E Eisner
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109; Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14853
| | - Ryan Rosario
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109
| | - Nelly Andarawis-Puri
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY 14853
| | - Ellen M Arruda
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109; Professor Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109; Professor Program in Macromolecular Science and Engineering, University of Michigan, Ann Arbor, MI 48109
| |
Collapse
|
21
|
Gallagher S, Barbe MF. The impaired healing hypothesis: a mechanism by which psychosocial stress and personal characteristics increase MSD risk? ERGONOMICS 2022; 65:573-586. [PMID: 34463204 PMCID: PMC9847256 DOI: 10.1080/00140139.2021.1974103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Accepted: 08/23/2021] [Indexed: 05/09/2023]
Abstract
While the effects of physical risk factors on MSD development have been a primary focus of musculoskeletal research, psychological stressors, and certain personal characteristics (e.g. ageing, sex, and obesity) are also associated with increased MSD risk. The psychological and personal characteristics listed above share a common characteristic: all are associated with disruption of the body's neuroendocrine and immune responses resulting in an impaired healing process. An impaired healing response may result in reduced fatigue life of musculoskeletal tissues due to a diminished ability to keep pace with accumulating damage (perhaps reparable under normal circumstances), and an increased vulnerability of damaged tissue to further trauma owing to the prolonged healing process. Research in engineered self-healing materials suggests that decreased healing kinetics in the presence of mechanical loading can substantially reduce the fatigue life of materials. A model of factors influencing damage accrual and healing will be presented. Practitioner summary: This article provides a potential reason why musculoskeletal disorder risk is affected by psychosocial stress, age, sex, and obesity. The reason is that these factors are all associated with a slower than normal healing response. This may lead to faster damage development in musculoskeletal tissues resulting in higher MSD risk.
Collapse
Affiliation(s)
- Sean Gallagher
- Industrial and Systems Engineering Department, Auburn University, Auburn, AL, USA
| | - Mary F Barbe
- Department of Anatomy and Cell Biology, Lewis Katz School of Medicine, Temple University, Philadelphia, PA, USA
| |
Collapse
|
22
|
Pedaprolu K, Szczesny S. A Novel, Open Source, Low-Cost Bioreactor for Load-Controlled Cyclic Loading of Tendon Explants. J Biomech Eng 2022; 144:1135618. [PMID: 35147179 DOI: 10.1115/1.4053795] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Indexed: 11/08/2022]
Abstract
A major risk factor for tendinopathy is tendon overuse (i.e., fatigue loading). Fatigue loading of tendon damages the extracellular matrix and induces tissue degeneration. However, the specific mechanisms linking tendon fatigue damage with tissue degeneration are unclear. While explant models of tendon fatigue loading have been used to address this knowledge gap, they predominantly employ bioreactors that apply cyclic displacements/strains rather than loads/stresses, which are more physiologically relevant. This is because of the technical complexity and cost of building a load-controlled bioreactor, which requires multiple motors, load cells, and computationally intensive feedback loops. Here, we present a novel, low-cost, load-controlled bioreactor that applies cyclic loading to multiple tendon explants by offloading weights from a single motorized stage. Using an optional load cell, we validated that the bioreactor can effectively provide load-controlled fatigue testing of mouse and rat tendon explants while maintaining tissue viability. Furthermore, all the design files, bill of materials, and operating software are available "open source" (https://github.com/Szczesnytendon/Bioreactor) so that anyone can easily manufacture and use the bioreactor for their own research. Therefore, this novel load-controlled bioreactor will enable researchers to study the mechanisms driving fatigue-induced tendon degeneration in a more physiologically relevant and cost-effective manner.
Collapse
Affiliation(s)
- Krishna Pedaprolu
- Department of Biomedical Engineering, Pennsylvania State University, University Park, Pennsylvania, Pennsylvania State University, CBE Building Suite 122, University Park, PA 16802
| | - Spencer Szczesny
- Department of Biomedical Engineering, Pennsylvania State University, University Park, Pennsylvania, Department of Orthopaedics and Rehabilitation, Pennsylvania State University, Hershey, Pennsylvania, Pennsylvania State University, CBE Building Suite 122, University Park, PA 16802
| |
Collapse
|
23
|
Örgel DM, Ranker DA, Wirries DN, Krettek PDC, Clausen DJD, Mommsen PDP. Bilateral Quadriceps Tendon Rupture and Femoral Neck Fracture After Generalized Tonic-Clonic Seizures: A Case Report. JBJS Case Connect 2022; 12:01709767-202203000-00044. [PMID: 35142749 DOI: 10.2106/jbjs.cc.20.00062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
CASE We report on a 19-year-old male renal transplant patient with multiple medical issues who sustained simultaneous bilateral quadriceps tendon ruptures and bilateral femoral neck fractures after 2 generalized tonic-clonic seizures. The quadriceps tendon ruptures were detected early surgically repaired; the femoral neck fractures were not detected and managed with bilateral total hip arthroplasty for almost 2 weeks. CONCLUSION Tonic-clonic seizures can be associated with unique and complex acute orthopaedic injuries that can be initially missed. Physicians should be cognizant of the need for a thorough medical history and physical examination to avoid orthopaedic postseizure missed diagnoses.
Collapse
Affiliation(s)
- Dr Marcus Örgel
- Trauma Department, Hannover Medical School (MHH), Hannover, Germany
| | - Dr Alexander Ranker
- Department of Rehabilitation Medicine, Hannover Medical School (MHH), Hannover, Germany
| | - Dr Nils Wirries
- Orthopedic Department, Diakovere Annastift, Hannover, Germany
| | | | | | | |
Collapse
|
24
|
Arant LR, Roth JD. Development and evaluation of ligament phantoms targeted for shear wave tensiometry. J Mech Behav Biomed Mater 2022; 126:104984. [PMID: 34857491 PMCID: PMC8792233 DOI: 10.1016/j.jmbbm.2021.104984] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 11/03/2021] [Accepted: 11/17/2021] [Indexed: 02/03/2023]
Abstract
Developing a shear wave tensiometer capable of non-invasively measuring ligament tension holds promise for enhancing research and clinical assessments of ligament function. Such development would benefit from tunable test specimens fabricated from well-characterized and consistent materials. Although previous work found that yarn can replicate the mechanical behavior of collateral ligaments, it is not obvious whether yarn-based phantoms would be suitable for development of a shear wave tensiometer for measuring ligament tension. Accordingly, the primary objective of this study was to characterize the mechanical properties and shear wave speed - stress relationships of ligament phantoms fabricated from yarn and silicone, and compare these results to published data from biological ligaments. We measured the mechanical properties and shear wave speeds during axial loading in nine phantoms with systematically varied material properties. We performed a simple linear regression between shear wave speed squared and axial stress to determine the shear wave speed - stress relationship for each phantom. We found comparable elastic moduli, hysteresis, and shear wave speed squared - stress regression parameters between the phantoms and collateral ligaments. For example, the ranges of the coefficients of determination (R2) and slopes across the nine phantoms were 0.84-0.95, and 0.78-1.27 kPa/m2/s2, respectively, which overlapped with the ranges found in a prior study in porcine collateral ligaments (0.84-0.996 and 0.34-1.18 kPa/m2/s2, respectively). Additionally, the shear wave speed squared - stress regression parameters varied predictably with the density of the phantom and the shear modulus of the silicone. In summary, we found that yarn-based phantoms serve as mechanical analogs for ligaments (i.e., are ligament mimicking), and thus, should prove beneficial for investigations into ligament structure-function relationships and in the development of a shear wave tensiometer for measuring ligament tension.
Collapse
Affiliation(s)
- Lesley R. Arant
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Joshua D. Roth
- Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI, USA,Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| |
Collapse
|
25
|
Ferreira E, Portugal D, Silva N, Peixoto C, Ladeira A, Matos C, Prates L. Rehabilitation of spontaneous muscle ruptures in a healthy young goalkeeper. THE JOURNAL OF THE INTERNATIONAL SOCIETY OF PHYSICAL AND REHABILITATION MEDICINE 2022. [DOI: 10.4103/jisprm-000140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
26
|
Chatterjee M, Muljadi PM, Andarawis-Puri N. The role of the tendon ECM in mechanotransduction: disruption and repair following overuse. Connect Tissue Res 2022; 63:28-42. [PMID: 34030531 DOI: 10.1080/03008207.2021.1925663] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Purpose: Tendon overuse injuries are prevalent conditions with limited therapeutic options to halt disease progression. The specialized extracellular matrix (ECM) both enables joint function and mediates mechanical signals to tendon cells, driving biological responses to exercise or injury. With overuse, tendon ECM composition and structure changes at multiple scales, disrupting mechanotransduction and resulting in inadequate repair and disease progression. This review highlights the multiscale ECM changes that occur with tendon overuse and corresponding effects on cell-matrix interactions and cellular response to load.Results: Different functional joint requirements and tendon types experience a wide range of loading profiles, creating varied downstream mechanical stimuli. Distinct ECM structure and mechanical properties within the fascicle matrix, interfascicle matrix, and enthesis and their varied disruption with overuse are considered. The pericellular matrix (PCM) comprising the microscale tendon cell environment has a unique composition that changes with overuse injury and exercise, suggesting an important role in mechanotransduction and promoting repair. Cell-matrix interactions are mediated by structures including cilia, integrins, connexins and cytoskeleton that signal downstream homeostasis, adaptation, or repair. ECM disruption with tendon overuse may cause altered mechanical loading and cell-matrix interactions, resulting in mechanobiological understimulation, apoptosis, and ineffective repair. Current interventions to promote repair of tendon overuse injuries including exercise, targeting cell signaling, and modulating inflammation are considered.Conclusion: Future therapeutics should be assessed with regard of their effects on multiscale mechanotransduction in addition to joint function, with consideration of the central role of ECM.
Collapse
Affiliation(s)
- Monideepa Chatterjee
- Nancy E. And Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Patrick M Muljadi
- Nancy E. And Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Nelly Andarawis-Puri
- Nancy E. And Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA.,Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, New York, USA.,Hospital for Special Surgery, New York, New York, USA
| |
Collapse
|
27
|
Al Makhzoomi AK, Kirk TB, Allison GT. A multiscale study of morphological changes in tendons following repeated cyclic loading. J Biomech 2021; 128:110790. [PMID: 34634539 DOI: 10.1016/j.jbiomech.2021.110790] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 09/30/2021] [Accepted: 09/30/2021] [Indexed: 11/30/2022]
Abstract
The response of white New Zealand rabbit Achilles tendons to load was assessed using mechanical measures and confocal arthroscopy (CA). The progression of fatigue-loading-induced damage of the macro- (tenocyte morphology, fiber anisotropy and waviness), as well as the mechanical profile, were assessed within the same non-viable intact tendon in response to prolonged cyclic and static loading (up to four hours) at different strain levels (3%, 6% and 9%). Strain-mediated repeated loading induced a significant decline in mechanical function (p < 0.05) with increased strain and cycles. Mechanical and structural resilience was lost with repeated loading (p < 0.05) at macroscales. The lengthening of D-periodicity correlated strongly with the overall tendon mechanical changes and loss of spindle shape in tenocytes. This is the first study to provide a clear concurrent assessment of form (morphology) and function (mechanics) of tendons undergoing different strain-mediated repeated loading at multiple-scale assessments. This study identifies a variety of multiscale properties that may contribute to the understanding of mechanisms of tendon pathology.
Collapse
Affiliation(s)
- Anas K Al Makhzoomi
- School of Allied Health, Faculty of Health Science, Curtin University, Perth, Western Australia, Australia.
| | - Thomas B Kirk
- School of Science, Engineering and Technology, RMIT University Vietnam, Ho Chi Minh City, Vietnam
| | - Garry T Allison
- Research Office, Curtin University, Perth, Western Australia, Australia
| |
Collapse
|
28
|
Williamson PM, Freedman BR, Kwok N, Beeram I, Pennings J, Johnson J, Hamparian D, Cohen E, Galloway JL, Ramappa AJ, DeAngelis JP, Nazarian A. Tendinopathy and tendon material response to load: What we can learn from small animal studies. Acta Biomater 2021; 134:43-56. [PMID: 34325074 DOI: 10.1016/j.actbio.2021.07.046] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 07/16/2021] [Accepted: 07/21/2021] [Indexed: 12/20/2022]
Abstract
Tendinopathy is a debilitating disease that causes as much as 30% of all musculoskeletal consultations. Existing treatments for tendinopathy have variable efficacy, possibly due to incomplete characterization of the underlying pathophysiology. Mechanical load can have both beneficial and detrimental effects on tendon, as the overall tendon response depends on the degree, frequency, timing, and magnitude of the load. The clinical continuum model of tendinopathy offers insight into the late stages of tendinopathy, but it does not capture the subclinical tendinopathic changes that begin before pain or loss of function. Small animal models that use high tendon loading to mimic human tendinopathy may be able to fill this knowledge gap. The goal of this review is to summarize the insights from in-vivo animal studies of mechanically-induced tendinopathy and higher loading regimens into the mechanical, microstructural, and biological features that help characterize the continuum between normal tendon and tendinopathy. STATEMENT OF SIGNIFICANCE: This review summarizes the insights gained from in-vivo animal studies of mechanically-induced tendinopathy by evaluating the effect high loading regimens have on the mechanical, structural, and biological features of tendinopathy. A better understanding of the interplay between these realms could lead to improved patient management, especially in the presence of painful tendon.
Collapse
|
29
|
Crawford SK, Rudolph A, Engel AJ, Ransone JW, Bashford GR. Novel Quantitative Ultrasonic Analysis of Patellar Tendon in Collegiate Athlete Following Bilateral Debridement: A Case Report. J Athl Train 2021; 56:1349-1354. [PMID: 34279639 DOI: 10.4085/1062-6050-0480.20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
An NCAA Division I female basketball athlete (20 years, 190.5 cm, 87 kg) suffered from chronic tendinopathy. After failed conservative treatments, the athlete underwent bilateral open patellar debridement surgery. Pain and dysfunction were assessed via the Victorian Institute of Sport-P (VISA-P) with concurrently collected B-mode ultrasound images of the patellar tendon throughout a 12 month rehabilitation. Peak spatial frequency radius (PSFR), a quantitative ultrasound parameter previously shown to correlate to collagen organization, was compared to changes in VISA-P scores. An overall increase in PSFR values across 0, 30, 60, and 90° of knee flexion were observed throughout recovery. Despite increased PSFR and returning to sport, the athlete still reported significant pain. This level 3 exploration case report provides novel insight into ultrasonically-measured structural changes of the patellar tendon following surgery and during rehabilitation of an athlete suffering from chronic tendinopathy. Perceived pain measurements were not necessarily related to structural adaptations.
Collapse
Affiliation(s)
- Scott K Crawford
- Department of Orthopedics & Rehabilitation, University of Wisconsin-Madison, Madison, WI, USA
| | - Ashley Rudolph
- Department of Biological Systems Engineering, University of Nebraska, Lincoln, NE, USA.,Department of Athletic Medicine, University of Nebraska, Lincoln, NE, USA
| | - Aaron J Engel
- Department of Biological Systems Engineering, University of Nebraska, Lincoln, NE, USA
| | - Jack W Ransone
- Department of Athletics, College of William and Mary, Williamsburg, VA, USA
| | - Gregory R Bashford
- Department of Biological Systems Engineering, University of Nebraska, Lincoln, NE, USA.,Nebraska Athletic Performance Laboratory, University of Nebraska, Lincoln, NE, USA
| |
Collapse
|
30
|
Quantifying supraspinatus tendon responses to exposures emulative of human physiological levels in an animal model. J Biomech 2021; 122:110476. [PMID: 33933860 DOI: 10.1016/j.jbiomech.2021.110476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 02/21/2021] [Accepted: 04/19/2021] [Indexed: 11/21/2022]
Abstract
Rotator cuff pathology typically originates in the supraspinatus tendon, but uncertainty exists on how combinations of glenohumeral elevation angle and load intensity influence responses of the intact, functional supraspinatus unit. This study exposed the supraspinatus tendon to mechanical loading scenarios emulative of derived muscle force and postural conditions measured in vivo to document its responses. Right shoulders from 48 Sprague-Dawley rats were placed into one of eight testing groups combining glenohumeral elevation angles (0/30/60/75°) and a high or low load intensity for 1500 cycles at 0.25 Hz using a custom mounting apparatus attached to a tensile testing system. Load intensities were derived from in vivo human partitional muscular activation levels collected previously and scaled to the animal model. Mechanical response variables examined included tangent stiffness and hysteresis, in addition to localized surface stretch ratios calculated via virtual tracking points. A significant three-way interaction (p = 0.0009) between elevation angle, load magnitude and cycle number occurred for tangent stiffness, with increasing angles, loads and cycles increasing stiffness by up to 49%. Longitudinal stretch ratios had significant interactions (p = 0.0396) with increasing elevation angles, load intensities and cycle numbers, and differences existed between the articular and bursal sides of the tendon. Complex interactions between angle, load and cycle number suggest higher abduction angles, increased load magnitude and higher loading cycles increase tangent stiffness, stretch ratios and hysteresis within the tendon.
Collapse
|
31
|
Lama M, Raveendranathan B, Brun J, Fernandes FM, Boissière C, Nassif N, Marcellan A. Biomimetic Tough Gels with Weak Bonds Unravel the Role of Collagen from Fibril to Suprafibrillar Self-Assembly. Macromol Biosci 2021; 21:e2000435. [PMID: 33881218 DOI: 10.1002/mabi.202000435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 03/04/2021] [Indexed: 11/10/2022]
Abstract
Biological tissues rich in type I collagen exhibit specific hierarchical fibrillar structures together with remarkable mechanical toughness. However, the role of collagen alone in their mechanical response at different structural levels is not fully understood. Here, it is proposed to rationalize such challenging interplay from a materials science perspective through the subtle control of this protein self-assembly in vitro. It is relied on a spray-processing approach to readily use the collagen phase diagram and set a palette of biomimetic self-assembled collagen gels in terms of suprafibrillar organization. Their mechanical responses unveil the involvement of mechanisms occurring either at fibrillar or suprafibrillar scales. Noticeably, both modulus at early stage of deformations and tensile toughness probe the suprafibrillar organization, while durability under cyclic loading and stress relaxation reflect mechanisms at the fibril level. By changing the physicochemical environment, the interfibrillar interactions are modified toward more biomimetic mechanical responses. The possibility of making tissue-like materials with versatile compositions and toughness opens perspectives in tissue engineering.
Collapse
Affiliation(s)
- Milena Lama
- Laboratoire Chimie de la Matière Condensée de Paris, Collège de France, Sorbonne Université, CNRS, 4 Place Jussieu, Paris, F-75005, France.,Sciences et Ingénierie de la Matière Molle, ESPCI Paris, PSL University, CNRS, Sorbonne Université, 10 rue Vauquelin, Paris, F-75005, France
| | - Biravena Raveendranathan
- Laboratoire Chimie de la Matière Condensée de Paris, Collège de France, Sorbonne Université, CNRS, 4 Place Jussieu, Paris, F-75005, France
| | - Julie Brun
- Laboratoire Chimie de la Matière Condensée de Paris, Collège de France, Sorbonne Université, CNRS, 4 Place Jussieu, Paris, F-75005, France.,Sciences et Ingénierie de la Matière Molle, ESPCI Paris, PSL University, CNRS, Sorbonne Université, 10 rue Vauquelin, Paris, F-75005, France
| | - Francisco M Fernandes
- Laboratoire Chimie de la Matière Condensée de Paris, Collège de France, Sorbonne Université, CNRS, 4 Place Jussieu, Paris, F-75005, France
| | - Cédric Boissière
- Laboratoire Chimie de la Matière Condensée de Paris, Collège de France, Sorbonne Université, CNRS, 4 Place Jussieu, Paris, F-75005, France
| | - Nadine Nassif
- Laboratoire Chimie de la Matière Condensée de Paris, Collège de France, Sorbonne Université, CNRS, 4 Place Jussieu, Paris, F-75005, France
| | - Alba Marcellan
- Sciences et Ingénierie de la Matière Molle, ESPCI Paris, PSL University, CNRS, Sorbonne Université, 10 rue Vauquelin, Paris, F-75005, France.,Institut Universitaire de France (IUF), 1, rue Descartes, Paris, F-75005, France
| |
Collapse
|
32
|
Haider IT, Lee M, Page R, Smith D, Edwards WB. Mechanical fatigue of whole rabbit-tibiae under combined compression-torsional loading is better explained by strained volume than peak strain magnitude. J Biomech 2021; 122:110434. [PMID: 33910082 DOI: 10.1016/j.jbiomech.2021.110434] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 03/11/2021] [Accepted: 04/08/2021] [Indexed: 11/29/2022]
Abstract
The mechanical fatigue behavior of whole bone is poorly defined, particularly for the combined loading modes that occur in vivo. The purpose of this study was to quantify the fatigue life of whole rabbit-tibiae under cyclic uniaxial compression and biaxial (compression and torsion) loading, and to explore the relationship between fatigue life and specimen-specific finite element (FE) predictions of stress/strain. Twelve tibiae were tested cyclically until failure across a range of uniaxial-compressive loads. Another twenty-two tibiae were separated into three groups and loaded biaxially; peak compressive load was constant in all three groups (50% ultimate force) but torsion was varied (0%, 25%, or 50% of ultimate torque). FE models with heterogeneous linear-elastic material properties were developed from computed tomography. We assessed peak stress/strain and stressed/strained volume based on principal stress/strain, as well as von Mises and pressure modified von Mises criteria. A logarithmic (r2 = 0.68; p < 0.001) relationship was observed between uniaxial-compressive load and fatigue life. Biaxial tests demonstrated that fatigue life decreased with superposed torsion (p = 0.034). Strained volume, based on a maximum principal strain or pressure modified von Mises strain criteria, were strong predictors of fatigue life under both uniaxial (r2 = 0.73-0.82) and biaxial (r2 = 0.59-0.60) loads, and these outperformed equivalent peak stress- and strain-based measures. Our findings highlight the importance of evaluating strain distributions, rather than peak stress or strain, to predict the fatigue behavior or whole bone, which has important implications for the study of stress fracture.
Collapse
Affiliation(s)
- Ifaz T Haider
- Human Performance Laboratory, Faculty of Kinesiology; McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.
| | - Mattea Lee
- Human Performance Laboratory, Faculty of Kinesiology; McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada; School of Kinesiology, Western University, London, Ontario, Canada
| | - Rebecca Page
- Human Performance Laboratory, Faculty of Kinesiology; McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Donovan Smith
- Human Performance Laboratory, Faculty of Kinesiology; McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - W Brent Edwards
- Human Performance Laboratory, Faculty of Kinesiology; McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
33
|
Pownder SL, Hayashi K, Lin BQ, Meyers KN, Caserto BG, Breighner RE, Potter HG, Koff MF. Differences in the magnetic resonance imaging parameter T2* may be identified during the course of canine patellar tendon healing: a pilot study. Quant Imaging Med Surg 2021; 11:1234-1246. [PMID: 33816163 DOI: 10.21037/qims-20-684] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background Previous studies have utilized ultrashort echo (UTE) magnetic resonance imaging (MRI), and derived T2* maps, to evaluate structures with highly ordered collagen structures such as tendon. T2* maps may provide a noninvasive means to assess tendon damage and healing. This pilot study evaluated the longitudinal relationship of an induced mechanical strain on the patellar tendon with corresponding UTE T2* metrics, histologic and biomechanical evaluation at two post-operative time points. Methods A total of 27 patellar tendons in male Beagles were surgically subjected to stretching by a small diameter (SmD) or a large diameter (LgD) diameter rod to induce damage due to strain, and evaluated at 4- and 8-week intervals using quantitative MRI (qMRI), biomechanical testing, and histology. A separate set of 16 limbs were used as controls. Results The tendons experienced a 67% and 17% prolongation of short T2* values as compared to controls at 4 and 8 weeks post-operatively, respectively. Histologic analysis displayed a trend of increased collagen disruption at 4 weeks followed by presence of greater organization at 8 weeks. Biomechanical evaluation found a reduction of tendon modulus and failure strain at both time points, and an increase in cross-sectional area at 4 weeks as compared to controls. Conclusions These findings display tendon healing in response to an imposed strain and present the utility of qMRI to evaluate longitudinal differences of patellar tendon T2* values in a model of induced subclinical tendon damage. The qMRI technique of UTE provides a means to non-invasively evaluate the healing process of a mechanically damaged tendon.
Collapse
Affiliation(s)
- Sarah L Pownder
- MRI Laboratory, Hospital for Special Surgery, New York, NY, USA
| | - Kei Hayashi
- Cornell University College of Veterinary Medicine, Ithaca, NY, USA
| | - Bin Q Lin
- MRI Laboratory, Hospital for Special Surgery, New York, NY, USA
| | | | | | | | - Hollis G Potter
- MRI Laboratory, Hospital for Special Surgery, New York, NY, USA
| | - Matthew F Koff
- MRI Laboratory, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
34
|
Firminger CR, Edwards WB. Effects of cyclic loading on the mechanical properties and failure of human patellar tendon. J Biomech 2021; 120:110345. [PMID: 33735631 DOI: 10.1016/j.jbiomech.2021.110345] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 02/18/2021] [Accepted: 02/22/2021] [Indexed: 12/31/2022]
Abstract
Patellar tendinopathy is a common overuse injury in sports such as volleyball, basketball, and long-distance running. Microdamage accumulation, in response to repetitive loading of the tendon, plays an important role in the pathophysiology of patellar tendinopathy. This damage presents mechanically as a reduction in Young's modulus and an increase in residual strain. In this study, 19 human patellar tendon samples underwent cyclic testing in load control until failure, segmented by four ramped tests where digital image correlation (DIC) was used to assess anterior surface strain distributions. Ramped tests were performed prior to cyclic testing and at timepoints corresponding to 10%, 20%, and 30% of cyclic stiffness reduction. Young's modulus significantly decreased and cyclic energy dissipation significantly increased over the course of cyclic testing. The DIC analysis illustrated a heterogeneous strain distribution, with strain concentrations increasing in magnitude and size over the course of cyclic testing. Peak stress and initial peak strain magnitudes significantly correlated with the number of cycles to failure (r2 = 0.65 and r2 = 0.57, respectively, p < 0.001); however, the rates of peak cyclic strain and modulus loss displayed the highest correlations with the number of cycles to failure (r2 = 96% and r2 = 86%, respectively, p < 0.001). The high correlation between the rates of peak cyclic strain and modulus loss suggest that non-invasive methods to continuously monitor tendon strain may provide meaningful predictions of overuse injury in the patellar tendon.
Collapse
Affiliation(s)
- Colin R Firminger
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Canada; Biomedical Engineering Graduate Program, University of Calgary, Canada; McCaig Institute for Bone and Joint Health, University of Calgary, Canada.
| | - W Brent Edwards
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Canada; Biomedical Engineering Graduate Program, University of Calgary, Canada; McCaig Institute for Bone and Joint Health, University of Calgary, Canada
| |
Collapse
|
35
|
Keir PJ, Farias Zuniga A, Mulla DM, Somasundram KG. Relationships and Mechanisms Between Occupational Risk Factors and Distal Upper Extremity Disorders. HUMAN FACTORS 2021; 63:5-31. [PMID: 31314601 DOI: 10.1177/0018720819860683] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
OBJECTIVE The relationships between workplace risk factors and upper extremity injuries from epidemiological and laboratory studies were examined. BACKGROUND Epidemiological studies are associated with several limitations, affecting the strength of association between risk factors and the development of injuries. METHOD In this narrative review, we identified epidemiological and laboratory studies (published primarily since 1997) investigating exposure to workplace risk factors (force, repetition, posture, vibration) and risk of hand/wrist tendon-related disorders, epicondylitis, and carpal tunnel syndrome (CTS). RESULTS Forceful exertions are strongly associated with hand/wrist tendon-related disorders, epicondylitis, and CTS. Dose-response relationships were found for epicondylitis (repetition) and CTS (posture). Interactions demonstrate multiplicative effects of risk factors for injury risk. Laboratory studies display clear associations between task demands and biomechanical measures linked to mechanisms for upper extremity injuries with animal models providing further evidence of a dose-response between risk factors and injury. CONCLUSION Forceful, repetitive work requiring non-neutral postures are associated with increasing risk of hand/wrist tendon-related disorders, epicondylitis, and CTS as evidenced by epidemiology studies and laboratory-based investigations of humans and animals. APPLICATION Understanding the relationship between exposure levels of workplace risk factors and upper extremity disorders can improve injury prevention and rehabilitation strategies.
Collapse
|
36
|
Mechanical properties of the different rotator cuff tendons in the rat are similarly and adversely affected by age. J Biomech 2021; 117:110249. [PMID: 33486263 DOI: 10.1016/j.jbiomech.2021.110249] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 12/28/2020] [Accepted: 01/03/2021] [Indexed: 12/20/2022]
Abstract
Rotator cuff tendon tears and tendinopathies are common injuries affecting a large portion of the population and can result in pain and joint dysfunction. Incidence of rotator cuff tears significantly increases with advancing age, and up to 90% of these tears involve the supraspinatus. Previous literature has shown that aging can lead to inferior mechanics, altered composition, and changes in structural properties of the supraspinatus. However, there is little known about changes in supraspinatus mechanical properties in context of other rotator cuff tendons. Alterations in tendon mechanical properties may indicate damage and an increased risk of rupture, and thus, the purpose of this study was to use a rat model to define age-related alterations in rotator cuff tendon mechanics to determine why the supraspinatus is more susceptible to tears due to aging than the infraspinatus, subscapularis, and teres minor. Fatigue, viscoelastic, and quasi-static properties were evaluated in juvenile, adult, aged, and geriatric rats. Aging ubiquitously and adversely affected all rotator cuff tendons tested, particularly leading to increased stiffness, decreased stress relaxation, and decreased fatigue secant and tangent moduli in geriatric animals, suggesting a common intrinsic mechanism due to aging in all rotator cuff tendons. This study demonstrates that aging has a significant effect on rotator cuff tendon mechanical properties, though the supraspinatus was not preferentially affected. Thus, we are unable to attribute the aging-associated increase in supraspinatus tears to its mechanical response alone.
Collapse
|
37
|
Siadat SM, Zamboulis DE, Thorpe CT, Ruberti JW, Connizzo BK. Tendon Extracellular Matrix Assembly, Maintenance and Dysregulation Throughout Life. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1348:45-103. [PMID: 34807415 DOI: 10.1007/978-3-030-80614-9_3] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
In his Lissner Award medal lecture in 2000, Stephen Cowin asked the question: "How is a tissue built?" It is not a new question, but it remains as relevant today as it did when it was asked 20 years ago. In fact, research on the organization and development of tissue structure has been a primary focus of tendon and ligament research for over two centuries. The tendon extracellular matrix (ECM) is critical to overall tissue function; it gives the tissue its unique mechanical properties, exhibiting complex non-linear responses, viscoelasticity and flow mechanisms, excellent energy storage and fatigue resistance. This matrix also creates a unique microenvironment for resident cells, allowing cells to maintain their phenotype and translate mechanical and chemical signals into biological responses. Importantly, this architecture is constantly remodeled by local cell populations in response to changing biochemical (systemic and local disease or injury) and mechanical (exercise, disuse, and overuse) stimuli. Here, we review the current understanding of matrix remodeling throughout life, focusing on formation and assembly during the postnatal period, maintenance and homeostasis during adulthood, and changes to homeostasis in natural aging. We also discuss advances in model systems and novel tools for studying collagen and non-collagenous matrix remodeling throughout life, and finally conclude by identifying key questions that have yet to be answered.
Collapse
Affiliation(s)
| | - Danae E Zamboulis
- Institute of Life Course and Medical Sciences, Faculty of Health and Life Sciences, University of Liverpool, Liverpool, UK
| | - Chavaunne T Thorpe
- Comparative Biomedical Sciences, The Royal Veterinary College, University of London, London, UK
| | - Jeffrey W Ruberti
- Department of Bioengineering, Northeastern University, Boston, MA, USA
| | - Brianne K Connizzo
- Department of Biomedical Engineering, Boston University, Boston, MA, USA.
| |
Collapse
|
38
|
Pugliese BR, Brisbois AL, Size KJ, St George LB, Hobbs SJ, Kirker-Head CA. Biomechanical and wearability testing of novel legwear for variably limiting extension of the metacarpophalangeal joint of horses. Am J Vet Res 2020; 82:39-47. [PMID: 33369493 DOI: 10.2460/ajvr.82.1.39] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate the ability of novel legwear designed to limit extension of the metacarpophalangeal joint (MCPJ) to redirect loading forces from the flexor apparatus during walk, trot, and canter on a treadmill and during unrestrained and restrained activity in a stall. ANIMALS 6 adult horses without musculoskeletal disease. PROCEDURES Legwear-derived force data were recorded under 4 conditions: inactive state (unlimited legwear extension) and 3 active (restrictive) states (mild, 30° extension; moderate, 20° extension; or maximum, 10° extension). Associations between peak legwear loads and torques among legwear states and treadmill gaits and stall activities were assessed. The hair coat and skin of the forelimbs were examined for any legwear-induced adverse effects after testing. RESULTS During the treadmill exercises, moderate restriction of legwear extension resulted in significantly higher peak load and torque than mild restriction, and faster speeds (canter vs walk or trot and trot vs walk) yielded significantly higher peak load and torque. During in-stall activity, maximum restriction of legwear extension yielded significantly higher peak load and torque than moderate restriction. Unrestrained in-stall activity resulted in significantly higher peak load and torque than restrained activity. The legwear caused minimal adverse effects on the hair coat and skin of the forelimbs. CONCLUSIONS AND CLINICAL RELEVANCE Findings suggested that the legwear variably reduced peak loads on the flexor apparatus. Extension of the MCPJ may be incrementally adjusted through the legwear such that return to activity may be controlled, and controlled return to activity is crucial for rehabilitating flexor apparatus injuries.
Collapse
|
39
|
Klich S, Ficek K, Krymski I, Klimek A, Kawczyński A, Madeleine P, Fernández-de-Las-Peñas C. Quadriceps and Patellar Tendon Thickness and Stiffness in Elite Track Cyclists: An Ultrasonographic and Myotonometric Evaluation. Front Physiol 2020; 11:607208. [PMID: 33381054 PMCID: PMC7767861 DOI: 10.3389/fphys.2020.607208] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Accepted: 11/25/2020] [Indexed: 12/12/2022] Open
Abstract
Track cyclists are required to perform short- and long-term efforts during sprint and endurance race events, respectively. The 200 m flying sprint races require maximal power output and anaerobic capacity, while the 4,000 m pursuit cyclists demand a high level of aerobic capacity. Our goal was to investigate spatial changes in morphological and mechanical properties displayed using 3D topographical maps of the quadriceps muscle and tendons after 200 m flying start and 4,000 m individual pursuit race in elite track cyclists. We hypothesized a non-uniform distribution of the changes in the quadriceps muscle stiffness (QMstiff), and acute alterations in quadriceps tendon (QTthick) and patellar tendon (PTthick) thickness. Fifteen men elite sprint and 15 elite men endurance track cyclists participated. Sprint track cyclists participated in a 200 m flying start, while endurance track cyclists in 4,000 m individual pursuit. Outcomes including QTthick (5–10–15 mm proximal to the upper edge of the patella), PTthick (5–10–15–20 mm inferior to the apex of the patella)—using ultrasonography evaluation, QMstiff, and quadriceps tendon stiffness (QTstiff) were measured according to anatomically defined locations (point 1–8) and patellar tendon stiffness (PTstiff)—using myotonometry, measured in a midway point between the patella distal and the tuberosity of tibial. All parameters were assessed before and after (up to 5 min) the 200 m or 4,000 m events. Sprint track cyclists had significantly larger QTthick and PTthick than endurance track cyclists. Post-hoc analysis showed significant spatial differences in QMstiff between rectus femoris, vastus lateralis, and vastus medialis in sprint track cyclists. At before race, sprint track cyclists presented significantly higher mean QTthick and PTthick, and higher QMstiff and the QTstiff, as compared with the endurance track cyclists. The observed changes in PTThick and QTThick were mostly related to adaptation-based vascularity and hypertrophy processes. The current study suggests that assessments using both ultrasonography and myotonometry provides crucial information about tendons and muscles properties and their acute adaptation to exercise. Higher stiffness in sprint compared with endurance track cyclists at baseline seems to highlight alterations in mechanical properties of the tendon and muscle that could lead to overuse injuries.
Collapse
Affiliation(s)
- Sebastian Klich
- Department of Paralympic Sport, University School of Physical Education in Wrocław, Wrocław, Poland
| | - Krzysztof Ficek
- Department of Physiotherapy, Academy of Physical Education in Katowice, Katowice, Poland.,Galen Orthopedic Center, Bieruń, Poland
| | | | - Andrzej Klimek
- Biomedical Science Institute, University School of Physical Education in Kraków, Kraków, Poland
| | - Adam Kawczyński
- Department of Paralympic Sport, University School of Physical Education in Wrocław, Wrocław, Poland
| | - Pascal Madeleine
- Department of Health Science and Technology, Sport Sciences-Performance and Technology, Aalborg University, Aalborg, Denmark
| | - Cesar Fernández-de-Las-Peñas
- Department of Physical Therapy, Occupational Therapy, Rehabilitation, and Physical Medicine, Universidad Rey Juan Carlos, Alcorcón, Spain.,Cátedra Institucional en Docencia, Clínica e Investigación en Fisioterapia: Terapia Manual, Punción Seca y Ejercicio Terapéutico, Universidad Rey Juan Carlos, Alcorcón, Spain
| |
Collapse
|
40
|
Zitnay JL, Jung GS, Lin AH, Qin Z, Li Y, Yu SM, Buehler MJ, Weiss JA. Accumulation of collagen molecular unfolding is the mechanism of cyclic fatigue damage and failure in collagenous tissues. SCIENCE ADVANCES 2020; 6:eaba2795. [PMID: 32923623 PMCID: PMC7455178 DOI: 10.1126/sciadv.aba2795] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Accepted: 07/14/2020] [Indexed: 05/04/2023]
Abstract
Overuse injuries to dense collagenous tissues are common, but their etiology is poorly understood. The predominant hypothesis that micro-damage accumulation exceeds the rate of biological repair is missing a mechanistic explanation. Here, we used collagen hybridizing peptides to measure collagen molecular damage during tendon cyclic fatigue loading and computational simulations to identify potential explanations for our findings. Our results revealed that triple-helical collagen denaturation accumulates with increasing cycles of fatigue loading, and damage is correlated with creep strain independent of the cyclic strain rate. Finite-element simulations demonstrated that biphasic fluid flow is a possible fascicle-level mechanism to explain the rate dependence of the number of cycles and time to failure. Molecular dynamics simulations demonstrated that triple-helical unfolding is rate dependent, revealing rate-dependent mechanisms at multiple length scales in the tissue. The accumulation of collagen molecular denaturation during cyclic loading provides a long-sought "micro-damage" mechanism for the development of overuse injuries.
Collapse
Affiliation(s)
- Jared L. Zitnay
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA
- Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT 84112, USA
| | - Gang Seob Jung
- Laboratory for Atomistic and Molecular Mechanics, Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Allen H. Lin
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA
- Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT 84112, USA
| | - Zhao Qin
- Laboratory for Atomistic and Molecular Mechanics, Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Yang Li
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA
| | - S. Michael Yu
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA
- Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, Salt Lake City, UT 84132, USA
| | - Markus J. Buehler
- Laboratory for Atomistic and Molecular Mechanics, Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Jeffrey A. Weiss
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA
- Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT 84112, USA
- Department of Orthopaedics and School of Computing, University of Utah, Salt Lake City, UT 84112, USA
- Corresponding author.
| |
Collapse
|
41
|
Histopathological changes in patellar tendon enthesis of rabbit induced by electrical stimulation intensity. J Orthop Sci 2020; 25:344-348. [PMID: 31101414 DOI: 10.1016/j.jos.2019.04.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2018] [Revised: 04/06/2019] [Accepted: 04/09/2019] [Indexed: 11/22/2022]
Abstract
BACKGROUND Enthesis injury is a common problem in athletes and workers, which is considered closely related to overuse. However, the early pathophysiologic changes of osteotendinous junction are not well understood, and moreover, few studies investigated the relationship between intensity and pathological changes. The purpose of this study was to evaluate microstructural changes induced by different loading intensities and to find out the threshold intensity. METHODS Forty-eight New Zealand White rabbits were randomly divided into six groups. One control group, the others were electrically stimulated to contract repetitively for 2 h per day, three days a week. 30% of peak tetanic force (7.06 N) was adopted to stimulate the rabbits in the 100% cyclic loading group. Other groups were stimulated with 20%, 40%, 60% and 80% of this force. After four weeks, prepared samples were stained with hematoxylin and eosin. RESULTS After 4 weeks of cyclic loading, the shape and the distribution of tendon cells in patellar enthesis changed, the arrangement of collagen fibers became disordered and the tidemark had become irregular or even disappeared. Different stimulus intensity caused a significant change of cell density in different groups (F = 10.19, P < 0.001). The cell densities of tendon were 34.3 ± 7.9 cells/100 μm2 (L60), 38.2 ± 5.9 cells/100 μm2 (L80), 43.8 ± 10.3 cells/100 μm2 (L100) respectively, which had significant difference with CON group 22.5 ± 3.5 cells/100 μm2. The thickness of fibrocartilage zone had no significant difference among the groups. CONCLUSIONS The changes of histomorphology with the increasing exercise intensity elucidated that the degree of enthesis microdamage was directly related to the intensity of exercises. The findings demonstrated that 18% (used in L60 group) of peak tetanic force was the threshold intensity which could induce pathological changes in enthesis in four weeks.
Collapse
|
42
|
Golman M, Wright ML, Wong TT, Lynch TS, Ahmad CS, Thomopoulos S, Popkin CA. Rethinking Patellar Tendinopathy and Partial Patellar Tendon Tears: A Novel Classification System. Am J Sports Med 2020; 48:359-369. [PMID: 31913662 DOI: 10.1177/0363546519894333] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Patellar tendinopathy is an overuse injury of the patellar tendon frequently affecting athletes involved in jumping sports. The tendinopathy may progress to partial patellar tendon tears (PPTTs). Current classifications of patellar tendinopathy are based on symptoms and do not provide satisfactory evidence-based treatment guidelines. PURPOSE To define the relationship between PPTT characteristics and treatment guidelines, as well as to develop a magnetic resonance imaging (MRI)-based classification system for partial patellar tendon injuries. STUDY DESIGN Cohort study (prognosis); Level of evidence, 2. METHODS MRI characteristics and clinical treatment outcomes were retrospectively reviewed for 85 patients with patellar tendinopathy, as well as 86 physically active control participants who underwent MRI of the knee for other conditions. A total of 56 patients had a PPTT and underwent further evaluation for tear size and location. The relationship between tear characteristics and clinical outcome was defined with use of statistical comparisons and univariate and logistic regression models. RESULTS Of the 85 patients, 56 had partial-thickness patellar tendon tears. Of these tears, 91% involved the posterior and posteromedial regions of the proximal tendon. On axial MRI views, patients with a partial tear had a mean tendon thickness of 10 mm, as compared with 6.2 mm for those without (P < .001). Eleven patients underwent surgery for their partial-thickness tear. All of these patients had a tear >50% of tendon thickness (median thickness of tear, 10.3 mm) on axial views. Logistic regression showed that tendon thickness >8.8 mm correlated with the presence of a partial tear, while tendon thickness >11.45 mm and tear thickness >55.7% predicted surgical management. CONCLUSION Partial-thickness tears are located posterior or posteromedially in the proximal patellar tendon. The most sensitive predictor for detecting the presence of a partial tear was patellar tendon thickness, in which thickness >8.8 mm was strongly correlated with a tear of the tendon. Tracking thickness changes on axial MRI may predict the effectiveness of nonoperative therapy: athletes with patellar tendon thickness >11.5 mm and/or >50% tear thickness on axial MRI were less likely to improve with nonoperative treatment. A novel proposed classification system for partial tears, the Popkin-Golman classification, can be used to guide treatment decisions for these patients.
Collapse
Affiliation(s)
- Mikhail Golman
- Department of Orthopedic Surgery, Columbia University Medical Center, New York, New York, USA.,Department of Biomedical Engineering, Columbia University, New York, New York, USA
| | - Margaret L Wright
- Center for Shoulder, Elbow and Sports Medicine, Columbia University, New York, New York, USA
| | - Tony T Wong
- Department of Musculoskeletal Radiology, Columbia University Medical Center, New York, New York, USA
| | - T Sean Lynch
- Center for Shoulder, Elbow and Sports Medicine, Columbia University, New York, New York, USA
| | - Christopher S Ahmad
- Center for Shoulder, Elbow and Sports Medicine, Columbia University, New York, New York, USA
| | - Stavros Thomopoulos
- Department of Orthopedic Surgery, Columbia University Medical Center, New York, New York, USA.,Department of Biomedical Engineering, Columbia University, New York, New York, USA
| | - Charles A Popkin
- Center for Shoulder, Elbow and Sports Medicine, Columbia University, New York, New York, USA
| |
Collapse
|
43
|
FIRMINGER COLINR, ASMUSSEN MICHAELJ, CIGOJA SASA, FLETCHER JAREDR, NIGG BENNOM, EDWARDS WBRENT. Cumulative Metrics of Tendon Load and Damage Vary Discordantly with Running Speed. Med Sci Sports Exerc 2020; 52:1549-1556. [DOI: 10.1249/mss.0000000000002287] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
44
|
Maeda E, Kuroyanagi K, Ando Y, Matsumoto T. Effects of Substrate Stiffness on Morphology and MMP-1 Gene Expression in Tenocytes Stimulated With Interleukin-1β. J Orthop Res 2020; 38:150-159. [PMID: 31254408 DOI: 10.1002/jor.24403] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Accepted: 06/18/2019] [Indexed: 02/04/2023]
Abstract
Tendon cells, tenocytes, are constantly subjected to mechanical stress in vivo, which maintains a level of cellular tension. When a tendon is subjected to overloading, local rupture of collagen fibers are induced, which deprives tenocytes of mechanical stress, lowers their cellular tension level and upregulates their catabolism. In addition, leukocytes are attracted to the rupture sites and produce interleukin-1β (IL-1β), and this exogenous IL-1β also stimulates tenocyte catabolism. We tested a hypothesis that catabolic tenocytes with low cellular tension at the rupture sites excessively respond to the exogenous IL-1β and further upregulate matrix metalloproteinase 1 (MMP-1) gene expression. Tenocytes from rabbit Achilles tendon were cultured on the following substrates: glass or polydimethylsiloxane micropillar substrates with a height of 2, 4, or 8 µm. Following a 3-day IL-1β stimulation at a concentration of 0, 1, 10, or 100 pM, the effects of IL-1β stimulation on cell morphology and MMP-1 gene expression was analysed with fluorescent microscopy and fluorescence in situ hybridization, respectively. In addition, the effects of IL-1β stimulation on cell membrane fluidity were examined. It was demonstrated that the cells on 8-µm-height micropillars exhibited a greater response than those on rigid substrates with flat (glass) and topologically the same surface (2-µm-height micropillars) to IL-1β when supplied at the same concentration. Besides this, membrane fluidity was lower in the cells on micropillars. Therefore, it appears that cellular attachment to softer substrates lowers the cellular actin cortex tension, reducing the membrane fluidity and possibly elevating the sensitivity of IL-1 receptors to ligand binding. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:150-159, 2020.
Collapse
Affiliation(s)
- Eijiro Maeda
- Biomechanics Laboratory, Department of Mechanical Systems Engineering, Graduate School of Engineering, Nagoya University, Nagoya, Japan
| | - Kaname Kuroyanagi
- Biomechanics Laboratory, Department of Mechanical Systems Engineering, Graduate School of Engineering, Nagoya University, Nagoya, Japan
| | - Yoriko Ando
- Biomechanics Laboratory, Department of Mechanical Systems Engineering, Graduate School of Engineering, Nagoya University, Nagoya, Japan
| | - Takeo Matsumoto
- Biomechanics Laboratory, Department of Mechanical Systems Engineering, Graduate School of Engineering, Nagoya University, Nagoya, Japan
| |
Collapse
|
45
|
Tendon tissue microdamage and the limits of intrinsic repair. Matrix Biol 2019; 85-86:68-79. [PMID: 31325483 DOI: 10.1016/j.matbio.2019.07.008] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 06/19/2019] [Accepted: 07/17/2019] [Indexed: 02/08/2023]
Abstract
The transmission of mechanical muscle force to bone for musculoskeletal stability and movement is one of the most important functions of tendon. The load-bearing tendon core is composed of highly aligned collagen-rich fascicles interspersed with stromal cells (tenocytes). Despite being built to bear very high mechanical stresses, supra-physiological/repetitive mechanical overloading leads to tendon microdamage in fascicles, and potentially to tendon disease and rupture. To date, it is unclear to what extent intrinsic healing mechanisms of the tendon core compartment can repair microdamage. In the present study, we investigated the healing capacity of the tendon core compartment in an ex vivo tissue explant model. To do so, we isolated rat tail tendon fascicles, damaged them by applying a single stretch to various degrees of sub-rupture damage and longitudinally assessed downstream functional and structural changes over a period of several days. Functional damage was assessed by changes in the elastic modulus of the material stress-strain curves, and biological viability of the resident tenocytes. Structural damage was quantified using a fluorescent collagen hybridizing peptide (CHP) to label mechanically disrupted collagen structures. While we observed functional mechanical damage for strains above 2% of the initial fascicle length, structural collagen damage was only detectable for 6% strain and beyond. Minimally loaded/damaged fascicles (2-4% strain) progressively lost elastic modulus over the course of tissue culture, despite their collagen structures remaining intact with high degree of maintained cell viability. In contrast, more severely overloaded fascicles (6-8% strain) with damage at the molecular/collagen level showed no further loss of the elastic modulus but markedly decreased cell viability. Surprisingly, in these heavily damaged fascicles the elastic modulus partially recovered, an effect also seen in further experiments on devitalized fascicles, implying the possibility of a non-cellular but matrix-driven mechanism of molecular repair. Overall, our findings indicate that the tendon core has very little capacity for self-repair of microdamage. We conclude that stromal tenocytes likely do not play a major role in anabolic repair of tendon matrix microdamage, but rather mediate catabolic matrix breakdown and communication with extrinsic cells that are able to effect tissue repair.
Collapse
|
46
|
FIRMINGER COLINR, BRUCE OLIVIAL, WANNOP JOHNW, STEFANYSHYN DARRENJ, EDWARDS WBRENT. Effect of Shoe and Surface Stiffness on Lower Limb Tendon Strain in Jumping. Med Sci Sports Exerc 2019; 51:1895-1903. [DOI: 10.1249/mss.0000000000002004] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
47
|
Lee AH, Elliott DM. Comparative multi-scale hierarchical structure of the tail, plantaris, and Achilles tendons in the rat. J Anat 2019; 234:252-262. [PMID: 30484871 PMCID: PMC6326909 DOI: 10.1111/joa.12913] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/18/2018] [Indexed: 12/19/2022] Open
Abstract
Rodent tendons are widely used to study human pathologies such as tendinopathy and repair, and to address fundamental physiological questions about development, growth, and remodeling. However, how the gross morphology and multi-scale hierarchical structure of rat tendons, such as the tail, plantaris, and Achilles tendons, compare with that of human tendons are unknown. In addition, there remains disagreement about terminology and definitions. Specifically, the definitions of fascicle and fiber are often dependent on diameter sizes, not their characteristic features, and these definitions impair the ability to compare hierarchical structure across species, where the sizes of the fiber and fascicle may change with animal size and tendon function. Thus, the objective of the study was to select a single species that is commonly used for tendon research (rat) and tendons with varying mechanical functions (tail, plantaris, Achilles) to evaluate the hierarchical structure at multiple length scales using histology, SEM, and confocal imaging. With the exception of the specialized rat tail tendon, we confirmed that in rat tendons there are no fascicles and the fiber is the largest subunit. In addition, we provided a structurally based definition of a fiber as a bundle of collagen fibrils that is surrounded by elongated cells, and this definition was supported by both histologically processed and unprocessed samples. In all rat tendons studied, the fiber diameters were consistently between 10 and 50 μm, and this diameter range appears to be conserved across larger species. Specific recommendations were made highlighting the strengths and limitations of each rat tendon as a research model. Understanding the hierarchical structure of tendon can advance the design and interpretation of experiments and development of tissue-engineered constructs.
Collapse
Affiliation(s)
- Andrea H. Lee
- Department of Biomedical EngineeringUniversity of DelawareNewarkUSA
| | - Dawn M. Elliott
- Department of Biomedical EngineeringUniversity of DelawareNewarkUSA
| |
Collapse
|
48
|
Ros SJ, Muljadi PM, Flatow EL, Andarawis-Puri N. Multiscale mechanisms of tendon fatigue damage progression and severity are strain and cycle dependent. J Biomech 2019; 85:148-156. [PMID: 30732906 DOI: 10.1016/j.jbiomech.2019.01.026] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2018] [Revised: 01/11/2019] [Accepted: 01/12/2019] [Indexed: 01/01/2023]
Abstract
Tendinopathies are common chronic injuries that occur when damage accumulation caused by sub-rupture fatigue loading outpaces repair. Studies have linked fatigue loading with various mechanical, structural, and biological changes associated with pathology. However, the multiscale progression of damage accumulation with respect to area, severity and the distinct contributions of strain level and number of cycles has not been fully elucidated. The objective of this study was to investigate multiscale mechanisms underlying fatigue damage accumulation and their effect on the cellular environment. Using an in situ model in rat tail tendon (RTT), fatigue loading was applied at various strains and cycle numbers to induce fatigue damage. Pre- and post- fatigue diagnostic mechanical testing, second harmonic generation (SHG) imaging, and transmission electron microscope (TEM) imaging were used to investigate extracellular and cellular damage modes at multiple scales. Fatigue loading at strains at or below 1.0% resulted in no significant changes in SHG damage area or severity and no changes in collagen fibril or cell morphology compared with controls. Fatigue loading at strains above 1.5% resulted in greater mechanical changes correlated with increased damage area measured by SHG and collagenous damage observed by TEM. Increased cycles at high strain further altered mechanical properties, increased structural damage severity (but not area), and altered TEM collagen rupture patterns. Cell morphology was similarly progressively affected with increased strain and cycle number. These damage mechanisms that may trigger degenerative changes characteristic of tendinopathy could be targeted as a part of prevention or therapy.
Collapse
Affiliation(s)
- Stephen J Ros
- Leni and Peter W. May Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Patrick M Muljadi
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, USA
| | - Evan L Flatow
- Leni and Peter W. May Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Nelly Andarawis-Puri
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, USA; Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, USA; Hospital for Special Surgery, New York, NY, USA.
| |
Collapse
|
49
|
Andarawis-Puri N, Flatow EL. Promoting effective tendon healing and remodeling. J Orthop Res 2018; 36:3115-3124. [PMID: 30175859 PMCID: PMC6608714 DOI: 10.1002/jor.24133] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Accepted: 08/06/2018] [Indexed: 02/04/2023]
Abstract
Daily activities subject our tendons to accumulation of sub-rupture fatigue injury which can lead to tendon rupture. Consequently, tendinopathies account for over 30% of musculoskeletal consultations. We adopted a multidisciplinary approach to determine the role of the extracellular matrix (ECM) in the pathogenesis of tendinopathy and impaired healing of ruptured tendons. We have been investigating three main areas: (i) the pathogenesis of tendon degeneration; (ii) approaches to promoting remodeling of sub-rupture fatigue injuries; and the (iii) role of the ECM in promoting scarless tendon healing. In this Kappa Delta Young Investigator award paper, we describe the key discoveries made in each of our three research areas of focus. Briefly, we discovered that sub-rupture fatigue damage can accumulate from just one bout of fatigue loading. Furthermore, any attempt to repair the fatigue damage diminishes as the severity of induced damage increases. We have utilized exercise to develop animal models of exercise-led degeneration and exercise-led repair of sub-rupture fatigue damage injuries, wherein underlying mechanisms can be uncovered, thereby overcoming a major hurdle to development of therapeutics. Since damage accumulation ultimately leads to rupture that is characterized by formation of a mechanically inferior scar, we have used the MRL/MpJ mouse to evaluate the role of the systemic environment and the local tendon environment in driving regeneration to identify new therapeutic pathways to promote scarless healing. Our data suggests that the therapeutic potential of the MRL/MpJ provisional ECM should be further explored as it may harness biological and structural mechanisms to promote scarless healing. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:3115-3124, 2018.
Collapse
Affiliation(s)
- Nelly Andarawis-Puri
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, New York
- Hospital for Special Surgery, New York, New York
| | - Evan L. Flatow
- Department of Orthopaedic Surgery, Mount Sinai West, New York, New York
| |
Collapse
|
50
|
Zitnay JL, Weiss JA. Load transfer, damage, and failure in ligaments and tendons. J Orthop Res 2018; 36:3093-3104. [PMID: 30175857 PMCID: PMC6454883 DOI: 10.1002/jor.24134] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 08/14/2018] [Indexed: 02/04/2023]
Abstract
The function of ligaments and tendons is to support and transmit loads applied to the musculoskeletal system. These tissues are often able to perform their function for many decades; however, connective tissue disease and injury can compromise ligament and tendon integrity. A range of protein and non-protein constituents, combined in a complex structural hierarchy from the collagen molecule to the tissue and covering nanometer to centimeter length scales, govern tissue function, and impart characteristic non-linear material behavior. This review summarizes the structure of ligaments and tendons, the roles of their constituent components for load transfer across the hierarchy of structure, and the current understanding of how damage occurs in these tissues. Disease and injury can alter the constituent make-up and structural organization of ligaments and tendons, affecting tissue function, while also providing insight to the role and interactions of individual constituents. The studies and techniques presented here have helped to understand the relationship between tissue constituents and the physical mechanisms (e.g., stretching, sliding) that govern material behavior at and between length scales. In recent years, new techniques have been developed to probe ever smaller length scales and may help to elucidate mechanisms of load transfer and damage and the molecular constituents involved in the in the earliest stages of ligament and tendon damage. A detailed understanding of load transfer and damage from the molecular to the tissue level may elucidate targets for the treatment of connective tissue diseases and inform practice to prevent and rehabilitate ligament and tendon injuries. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:3093-3104, 2018.
Collapse
Affiliation(s)
- Jared L. Zitnay
- Department of Bioengineering, and Scientific Computing and Imaging Institute University of Utah
| | - Jeffrey A. Weiss
- Department of Bioengineering, and Scientific Computing and Imaging Institute University of Utah,Department of Orthopaedics, University of Utah
| |
Collapse
|