1
|
Bennett HJ, Estler K, Valenzuela K, Weinhandl JT. Predicting Knee Joint Contact Forces During Normal Walking Using Kinematic Inputs With a Long-Short Term Neural Network. J Biomech Eng 2024; 146:081004. [PMID: 38270972 DOI: 10.1115/1.4064550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Accepted: 01/19/2024] [Indexed: 01/26/2024]
Abstract
Knee joint contact forces are commonly estimated via surrogate measures (i.e., external knee adduction moments or musculoskeletal modeling). Despite its capabilities, modeling is not optimal for clinicians or persons with limited experience. The purpose of this study was to design a novel prediction method for knee joint contact forces that is simplistic in terms of required inputs. This study included marker trajectories and instrumented knee forces during normal walking from the "Grand Challenge" (n = 6) and "CAMS" (n = 2) datasets. Inverse kinematics were used to derive stance phase hip (sagittal, frontal, transverse), knee (sagittal, frontal), ankle (sagittal), and trunk (frontal) kinematics. A long-short term memory network (LSTM) was created using matlab to predict medial and lateral knee force waveforms using combinations of the kinematics. The Grand Challenge and CAMS datasets trained and tested the network, respectively. Musculoskeletal modeling forces were derived using static optimization and joint reaction tools in OpenSim. Waveform accuracy was determined as the proportion of variance and root-mean-square error between network predictions and in vivo data. The LSTM network was highly accurate for medial forces (R2 = 0.77, RMSE = 0.27 BW) and required only frontal hip and knee and sagittal hip and ankle kinematics. Modeled medial force predictions were excellent (R2 = 0.77, RMSE = 0.33 BW). Lateral force predictions were poor for both methods (LSTM R2 = 0.18, RMSE = 0.08 BW; modeling R2 = 0.21, RMSE = 0.54 BW). The designed LSTM network outperformed most reports of musculoskeletal modeling, including those reached in this study, revealing knee joint forces can accurately be predicted by using only kinematic input variables.
Collapse
Affiliation(s)
- Hunter J Bennett
- Neuromechanics Laboratory, Old Dominion University, 1007 Student Recreation Center, Norfolk, VA 23529
| | - Kaileigh Estler
- Department of Kinesiology, Recreation, and Sport Studies, The University of Tennessee, Knoxville, TN 37996
- University of Tennessee at Knoxville
| | - Kevin Valenzuela
- Department of Kinesiology, California State University, Long Beach, CA 90840
| | - Joshua T Weinhandl
- Department of Kinesiology, Recreation, and Sport Studies, The University of Tennessee, Knoxville, TN 37996
| |
Collapse
|
2
|
Stewart KM, Klute GK, Neptune RR. Influence of Walking Over Unexpected Uneven Terrain on Joint Loading for Individuals With Transtibial Amputation. J Biomech Eng 2024; 146:081009. [PMID: 38470376 DOI: 10.1115/1.4065045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Accepted: 02/23/2024] [Indexed: 03/13/2024]
Abstract
Individuals with transtibial amputation (TTA) experience asymmetric lower-limb loading which can lead to joint pain and injuries. However, it is unclear how walking over unexpected uneven terrain affects their loading patterns. This study sought to use modeling and simulation to determine how peak joint contact forces and impulses change for individuals with unilateral TTA during an uneven step and subsequent recovery step and how those patterns compare to able-bodied individuals. We expected residual limb loading during the uneven step and intact limb loading during the recovery step would increase relative to flush walking. Further, individuals with TTA would experience larger loading increases compared to able-bodied individuals. Simulations of individuals with TTA showed during the uneven step, changes in joint loading occurred at all joints except the prosthetic ankle relative to flush walking. During the recovery step, intact limb joint loading increased in early stance relative to flush walking. Simulations of able-bodied individuals showed large increases in ankle joint loading for both surface conditions. Overall, increases in early stance knee joint loading were larger for those with TTA compared to able-bodied individuals during both steps. These results suggest that individuals with TTA experience altered joint loading patterns when stepping on uneven terrain. Future work should investigate whether an adapting ankle-foot prosthesis can mitigate these changes to reduce injury risk.
Collapse
Affiliation(s)
- Kristen M Stewart
- Walker Department of Mechanical Engineering, The University of Texas at Austin, 204 East Dean Keeton Street, Austin, TX 78712-1591
- The University of Texas at Austin
| | - Glenn K Klute
- Department of Veterans Affairs, Puget Sound Health Care System, 1660 South Columbian Way, MS-151, Seattle, WA 98118;Department of Mechanical Engineering, University of Washington, 3900 East Stevens Way NE, Seattle, WA 98195
| | - Richard R Neptune
- Walker Department of Mechanical Engineering, The University of Texas at Austin, 204 East Dean Keeton Street, Austin, TX 78712-1591
| |
Collapse
|
3
|
Guan S, Dumas R, Pandy MG. Tibiofemoral Slip Velocity in Total Knee Arthroplasty is Design-Invariant but Activity-Dependent. Ann Biomed Eng 2024; 52:1779-1794. [PMID: 38530534 DOI: 10.1007/s10439-024-03490-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 03/11/2024] [Indexed: 03/28/2024]
Abstract
Tibiofemoral slip velocity is a key contributor to total knee arthroplasty (TKA) component wear, yet few studies have evaluated this quantity in vivo. The aim of the present study was to measure and compare tibiofemoral slip velocities in 3 TKA designs for a range of daily activities. Mobile biplane X-ray imaging was used to measure 6-degree-of-freedom tibiofemoral kinematics and the locations of articular contact in 75 patients implanted with a posterior-stabilized, cruciate-retaining, or medial-stabilized design while each patient performed level walking, step up, step down, sit-to-stand, and stand-to-sit. Using these data, tibiofemoral slip velocity was calculated for the duration of each activity for each TKA design. The pattern of tibiofemoral slip velocity was similar for all 3 TKA designs within each activity but markedly different across the 5 activities tested, with the magnitude of peak slip velocity being significantly higher in level walking (range: 158-211 mm/s) than in all other activities (range: 43-75 mm/s). The pattern of tibiofemoral slip velocity in both the medial and lateral compartments closely resembled the pattern of tibiofemoral (knee) flexion angular velocity, with a strong linear relationship observed between slip velocity and flexion angular velocity (r = 0.81-0.97). Tibiofemoral slip velocity was invariant to TKA design but was significantly affected by activity type. Our measurements of slip velocity and articular contact locations for a wide range of daily activities may be used as inputs in joint simulator testing protocols and computational models developed to estimate TKA component wear.
Collapse
Affiliation(s)
- Shanyuanye Guan
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria, 3010, Australia
| | - Raphael Dumas
- University of Lyon, University Gustave Eiffel, University Claude Bernard Lyon 1, LBMC UMR T_9406, F-69622, Lyon, France
| | - Marcus G Pandy
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria, 3010, Australia.
| |
Collapse
|
4
|
Yamagata M, Tateuchi H, Asayama A, Ichihashi N. Relationship of the weaknesses of knee- and hip-spanning muscles with knee compression forces during stair ascent and descent. Gait Posture 2024; 113:1-5. [PMID: 38820763 DOI: 10.1016/j.gaitpost.2024.05.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 04/05/2024] [Accepted: 05/20/2024] [Indexed: 06/02/2024]
Abstract
BACKGROUND The musculoskeletal models have been improved to estimate accurate knee compression force (KCF) and have been used to reveal the causal relationship between KCF and muscle weakness. Previous studies have explored how muscle weakness influences the KCF during gait; however, the influence of muscle weakness is possibly larger during activities that require deeper knee flexion (e.g., stair ambulation) than other activities (e.g., gait) because of the small knee contact area of articular surfaces. RESEARCH QUESTION To explore how muscle weakness influences the KCF during stair ambulation. METHODS Ten young adults performed stair ascent and descent tasks at a comfortable speed. Based on a previous study, we created muscle weakness models of rectus femoris (RF), vastus muscles (VAS), gluteus medius (Gmed), and gluteus maximus (Gmax), and the medial and lateral KCF (KCFmed and KCFlat) during stair ambulation were calculated. RESULTS Similar to the gait, the Gmed weakness increased KCFmed and decreased KCFlat during stair ascent and descent. Whereas, unlike the gait, the Gmax weakness increased KCFmed during stair ascent and the VAS weakness decreased KCFmed and KCFlat during stair ascent and descent. Moreover, the percentage changes in KCF were similar (or large) during stair ambulation compared with those during gait. SIGNIFICANCE Considering the KCF alterations caused by each muscle weakness, the weaknesses in Gmax and Gmed might lead to cartilage loss and pain in the knee, and the VAS weakness might lead to low stability of the knee. The symptom during stair ambulation might help precisely identify the muscle requiring rehabilitation.
Collapse
Affiliation(s)
- Momoko Yamagata
- Faculty of Rehabilitation, Kansai Medical University, 18-89 Uyama Higashimachi, Hirakata, Osaka 573-1136, Japan; Department of Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo, Kyoto 606-8507, Japan.
| | - Hiroshige Tateuchi
- Department of Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo, Kyoto 606-8507, Japan
| | - Akihiro Asayama
- Department of Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo, Kyoto 606-8507, Japan
| | - Noriaki Ichihashi
- Department of Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo, Kyoto 606-8507, Japan
| |
Collapse
|
5
|
Zou J, Zhang X, Zhang Y, Jin Z. Prediction of medial knee contact force using multisource fusion recurrent neural network and transfer learning. Med Biol Eng Comput 2024; 62:1333-1346. [PMID: 38182944 DOI: 10.1007/s11517-023-03011-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Accepted: 12/27/2023] [Indexed: 01/07/2024]
Abstract
Estimation of knee contact force (KCF) during gait provides essential information to evaluate knee joint function. Machine learning has been employed to estimate KCF because of the advantages of low computational cost and real-time. However, the existing machine learning models do not adequately consider gait-related data's temporal-dependent, multidimensional, and highly heterogeneous nature. This study is aimed at developing a multisource fusion recurrent neural network to predict the medial condyle KCF. First, a multisource fusion long short-term memory (MF-LSTM) model was established. Then, we developed a transfer learning strategy based on the MF-LSTM model for subject-specific medial KCF prediction. Four subjects with instrumented tibial prostheses were obtained from the literature. The results showed that the MF-LSTM model could predict medial KCF to a certain high level of accuracy (the mean of ρ = 0.970). The transfer learning model improved the prediction accuracy (the mean of ρ = 0.987). This study shows that the MF-LSTM model is a powerful and accurate computational tool for medial KCF prediction. Introducing transfer learning techniques could further improve the prediction performance for the target subject. This coupling strategy can help clinicians accurately estimate and track joint contact forces in real time.
Collapse
Affiliation(s)
- Jianjun Zou
- School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Xiaogang Zhang
- School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, 610031, China.
| | - Yali Zhang
- School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Zhongmin Jin
- School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, 610031, China
- School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
- School of Mechanical Engineering, University of Leeds, Leeds, LS2 9JT, UK
| |
Collapse
|
6
|
Perrone M, Guidetti M, Galli M, Nho SJ, Wimmer MA, Malloy P. Hip joint contact forces are lower in people with femoroacetabular impingement syndrome during squat tasks. J Orthop Res 2024; 42:1045-1053. [PMID: 38032092 DOI: 10.1002/jor.25744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 10/16/2023] [Accepted: 11/20/2023] [Indexed: 12/01/2023]
Abstract
It remains unknown if hip joint forces during squat tasks are altered in people with femoroacetabular impingement syndrome (FAIS). The aim of this study is to compare hip joint forces between people with FAIS and healthy controls during double leg squat and single leg squat tasks and within limbs during a single leg squat task in people with FAIS. Kinematic and kinetic data were collected in eight people with FAIS and eight healthy matched controls using 3D motion capture and force plates. AnyBody Modeling System was used to perform musculoskeletal simulations to estimate hip joint angles, forces, and moments for all participants. Estimates were postprocessed with AnyPyTools and converted into normalized time series to be compared using a 1D statistical nonparametric mapping (SnPM) approach. SnPM with an independent samples t-test model was used to compare people with FAIS to controls, while a paired samples model was used to compare involved to uninvolved limb in people with FAIS. Patients demonstrated lower proximodistal force compared to controls (p < 0.01) and compared to the uninvolved side (p = 0.01) for single leg squat. The smaller joint contact forces in people with FAIS compared to controls could represent a strategy of reduced muscle forces to avoid pain and symptoms during this high demand task. These findings when combined with imaging data could help assess the severity of FAIS on hip related function during higher demand tasks.
Collapse
Affiliation(s)
- Mattia Perrone
- Department of Physical Therapy, Arcadia University, Glenside, Pennsylvania, USA
- Department of Orthopedic Surgery, Division of Sports Medicine, Young Adult Hip Surgery Program, Rush University Medical Center, Chicago, Illinois, USA
- Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
- Department of Electronics, Information and Bioengineering, Politecnico Di Milano, Milan, Italy
| | - Martina Guidetti
- Department of Orthopedic Surgery, Division of Sports Medicine, Young Adult Hip Surgery Program, Rush University Medical Center, Chicago, Illinois, USA
| | - Manuela Galli
- Department of Electronics, Information and Bioengineering, Politecnico Di Milano, Milan, Italy
| | - Shane J Nho
- Department of Orthopedic Surgery, Division of Sports Medicine, Young Adult Hip Surgery Program, Rush University Medical Center, Chicago, Illinois, USA
| | - Markus A Wimmer
- Department of Orthopedic Surgery, Division of Sports Medicine, Young Adult Hip Surgery Program, Rush University Medical Center, Chicago, Illinois, USA
- Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Philip Malloy
- Department of Physical Therapy, Arcadia University, Glenside, Pennsylvania, USA
- Department of Orthopedic Surgery, Division of Sports Medicine, Young Adult Hip Surgery Program, Rush University Medical Center, Chicago, Illinois, USA
| |
Collapse
|
7
|
Markström JL, Grinberg Y, Sole G, Häger CK. Strategies for knee stabilising and pivot-shift avoidance in a step-down and cross-over task observed sub-acutely after anterior cruciate ligament reconstruction. Clin Biomech (Bristol, Avon) 2024; 115:106255. [PMID: 38669919 DOI: 10.1016/j.clinbiomech.2024.106255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 04/17/2024] [Accepted: 04/22/2024] [Indexed: 04/28/2024]
Abstract
BACKGROUND Individuals with a recent anterior cruciate ligament reconstruction may demonstrate an altered movement strategy for protecting the knee and maintaining stability. Altered knee movement might lead to abnormal intra-articular load, potentially contributing to early knee osteoarthritis onset. A protective strategy may be particularly evident during active tasks that induce a pivot-shift manoeuvre, such as a step-down and cross-over task. In this study, we investigated whether knee joint mechanics and muscle activity differed between participants early (∼3 months) following reconstruction (n = 35) to uninjured controls (n = 35) during a step-down and cross-over task with a 45° change-of-direction. METHODS We used motion capture, force plates and surface electromyography to compare time-normalised curves of sagittal and transverse-plane knee mechanics and muscle activity during the cross-over phase between groups using functional t-tests. We also compared knee mechanics between sides within the injured group and compared discrete outcomes describing the cross-over phase between groups. FINDINGS Compared to controls, the injured participants had greater knee flexion angle and moment, lower internal rotation moment, more preparatory foot rotation of the pivoting leg, a smaller cross-over angle, and a longer cross-over phase for both the injured and uninjured sides. The injured leg also had greater biceps femoris and vastus medialis muscle activity compared to controls and different knee mechanics than the uninjured leg. INTERPRETATION Individuals with anterior cruciate ligament reconstruction showed a knee-stabilising and pivot-shift avoidance strategy for both legs early in rehabilitation. These results may reflect an altered motor representation and motivate considerations early in rehabilitation.
Collapse
Affiliation(s)
- Jonas L Markström
- Department of Community Medicine and Rehabilitation, Section of Physiotherapy, Umeå University, Sweden; Department of Statistics, Umeå School of Business, Economics and Statistics, Umeå University, Sweden.
| | - Yevgenia Grinberg
- Department of Community Medicine and Rehabilitation, Section of Physiotherapy, Umeå University, Sweden
| | - Gisela Sole
- Centre for Health, Activity and Rehabilitation Research, School of Physiotherapy, University of Otago, Dunedin, New Zealand
| | - Charlotte K Häger
- Department of Community Medicine and Rehabilitation, Section of Physiotherapy, Umeå University, Sweden
| |
Collapse
|
8
|
Colbrunn RW, Loss JG, Gillespie CM, Pace EB, Nagle TF. Methodology for Robotic In Vitro Testing of the Knee. J Knee Surg 2024. [PMID: 38513696 DOI: 10.1055/a-2292-1157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/23/2024]
Abstract
The knee joint plays a pivotal role in mobility and stability during ambulatory and standing activities of daily living (ADL). Increased incidence of knee joint pathologies and resulting surgeries has led to a growing need to understand the kinematics and kinetics of the knee. In vivo, in silico, and in vitro testing domains provide researchers different avenues to explore the effects of surgical interactions on the knee. Recent hardware and software advancements have increased the flexibility of in vitro testing, opening further opportunities to answer clinical questions. This paper describes best practices for conducting in vitro knee biomechanical testing by providing guidelines for future research. Prior to beginning an in vitro knee study, the clinical question must be identified by the research and clinical teams to determine if in vitro testing is necessary to answer the question and serve as the gold standard for problem resolution. After determining the clinical question, a series of questions (What surgical or experimental conditions should be varied to answer the clinical question, what measurements are needed for each surgical or experimental condition, what loading conditions will generate the desired measurements, and do the loading conditions require muscle actuation?) must be discussed to help dictate the type of hardware and software necessary to adequately answer the clinical question. Hardware (type of robot, load cell, actuators, fixtures, motion capture, ancillary sensors) and software (type of coordinate systems used for kinematics and kinetics, type of control) can then be acquired to create a testing system tailored to the desired testing conditions. Study design and verification steps should be decided upon prior to testing to maintain the accuracy of the collected data. Collected data should be reported with any supplementary metrics (RMS error, dynamic statistics) that help illuminate the reported results. An example study comparing two different anterior cruciate ligament reconstruction techniques is provided to demonstrate the application of these guidelines. Adoption of these guidelines may allow for better interlaboratory result comparison to improve clinical outcomes.
Collapse
|
9
|
Guo N, Smith CR, Schütz P, Trepczynski A, Moewis P, Damm P, Maas A, Grupp TM, Taylor WR, Hosseini Nasab SH. Posterior tibial slope influences joint mechanics and soft tissue loading after total knee arthroplasty. Front Bioeng Biotechnol 2024; 12:1352794. [PMID: 38686117 PMCID: PMC11056792 DOI: 10.3389/fbioe.2024.1352794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 03/26/2024] [Indexed: 05/02/2024] Open
Abstract
As a solution to restore knee function and reduce pain, the demand for Total Knee Arthroplasty (TKA) has dramatically increased in recent decades. The high rates of dissatisfaction and revision makes it crucially important to understand the relationships between surgical factors and post-surgery knee performance. Tibial implant alignment in the sagittal plane (i.e., posterior tibia slope, PTS) is thought to play a key role in quadriceps muscle forces and contact conditions of the joint, but the underlying mechanisms and potential consequences are poorly understood. To address this biomechanical challenge, we developed a subject-specific musculoskeletal model based on the bone anatomy and precise implantation data provided within the CAMS-Knee datasets. Using the novel COMAK algorithm that concurrently optimizes joint kinematics, together with contact mechanics, and muscle and ligament forces, enabled highly accurate estimations of the knee joint biomechanics (RMSE <0.16 BW of joint contact force) throughout level walking and squatting. Once confirmed for accuracy, this baseline modelling framework was then used to systematically explore the influence of PTS on knee joint biomechanics. Our results indicate that PTS can greatly influence tibio-femoral translations (mainly in the anterior-posterior direction), while also suggesting an elevated risk of patellar mal-tracking and instability. Importantly, however, an increased PTS was found to reduce the maximum tibio-femoral contact force and improve efficiency of the quadriceps muscles, while also reducing the patellofemoral contact force (by approximately 1.5% for each additional degree of PTS during walking). This study presents valuable findings regarding the impact of PTS variations on the biomechanics of the TKA joint and thereby provides potential guidance for surgically optimizing implant alignment in the sagittal plane, tailored to the implant design and the individual deficits of each patient.
Collapse
Affiliation(s)
- Ning Guo
- Institute for Biomechanics, Department of Health Sciences and Technology, ETH Zürich, Zürich, Switzerland
| | - Colin R. Smith
- Department of Biomedical Engineering, Steadman Philippon Research Institute, Vail, CO, United States
| | - Pascal Schütz
- Institute for Biomechanics, Department of Health Sciences and Technology, ETH Zürich, Zürich, Switzerland
| | - Adam Trepczynski
- Julius Wolff Institute, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Philippe Moewis
- Julius Wolff Institute, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Philipp Damm
- Julius Wolff Institute, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Allan Maas
- Aesculap AG, Tuttlingen, Germany
- Department of Orthopaedic and Trauma Surgery, Ludwig Maximilians University Munich, Musculoskeletal University Center Munich (MUM), Munich, Germany
| | - Thomas M. Grupp
- Aesculap AG, Tuttlingen, Germany
- Department of Orthopaedic and Trauma Surgery, Ludwig Maximilians University Munich, Musculoskeletal University Center Munich (MUM), Munich, Germany
| | - William R. Taylor
- Institute for Biomechanics, Department of Health Sciences and Technology, ETH Zürich, Zürich, Switzerland
| | | |
Collapse
|
10
|
Liebermann DG, Markström JL, Selling J, Häger CK. Spatiotemporal lower-limb asymmetries during stair descent in athletes following anterior cruciate ligament reconstruction. J Electromyogr Kinesiol 2024; 75:102868. [PMID: 38359579 DOI: 10.1016/j.jelekin.2024.102868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 01/29/2024] [Accepted: 02/05/2024] [Indexed: 02/17/2024] Open
Abstract
PURPOSE This study evaluated motor control recovery at different times following anterior cruciate ligament reconstruction (ACLR) by investigating lower-limb spatiotemporal symmetry during stair descent performances. METHODS We used a cross-sectional design to compare asymptomatic athletes (Controls, n = 18) with a group of people with ACLR (n = 49) divided into three time-from-ACLR subgroups (Early: <6 months, n = 17; Mid: 6-18 months, n = 16; Late: ≥18 months, n = 16). We evaluated: "temporal symmetry" during the stance subphases (single-support, first and second double-support) and "spatial symmetry" for hip-knee-ankle intra-joint angular displacements during the stance phase using a dissimilarity index applied on superimposed 3D phase plots. RESULTS We found significant between-group differences in temporal variables (p ≤ 0.001). Compared to Controls, both Early and Mid (p ≤ 0.05) showed asymmetry in the first double-support time (longer for their injured vs. non-injured leg), while Early generally also showed longer durations in all other phases, regardless of stepping leg. No statistically significant differences were found for spatial intra-joint symmetry between groups. CONCLUSION Temporal but not spatial asymmetry in stair descent is often present early after ACLR; it may remain for up to 18 months and may underlie subtle intra- and inter-joint compensations. Spatial asymmetry may need further exploration.
Collapse
Affiliation(s)
- Dario G Liebermann
- Dept. of Physical Therapy, Stanley Steyer School of Health Professions, Faculty of Medicine, Tel Aviv University, Israel.
| | - Jonas L Markström
- Dept. of Community Medicine and Rehabilitation, Section of Physiotherapy, Umeå University, Sweden
| | - Jonas Selling
- Dept. of Community Medicine and Rehabilitation, Section of Physiotherapy, Umeå University, Sweden
| | - Charlotte K Häger
- Dept. of Community Medicine and Rehabilitation, Section of Physiotherapy, Umeå University, Sweden.
| |
Collapse
|
11
|
Kang M, Seo S, Lee H, Han MW. Knee Measurement System with Osteoarthritis Levels Using Artificial Cartilage and Skeletons. Biomimetics (Basel) 2024; 9:166. [PMID: 38534851 DOI: 10.3390/biomimetics9030166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 03/04/2024] [Accepted: 03/07/2024] [Indexed: 03/28/2024] Open
Abstract
Knee osteoarthritis (OA), also known as degenerative arthritis, is a disease characterized by irreversible changes in the cartilage and bones comprising the joints, resulting in pain, impaired function, and deformity. Furthermore, independent of natural aging, the rate of change in joint cartilage has increased in recent years, which is mainly attributed to environmental factors. The rising incidence of knee-related disorders emphasizes the importance of analyzing the morphology and kinematics of knee structure. This study introduces a knee measurement system designed to replicate the motions of knee using 3D-printing technology, providing insights into knee mechanics with OA level. The research explores the stages of OA using the Kellgren-Lawrence (KL) grade scale, highlighting the variations in the force applied to the knee bone according to movement. The developed knee-simulation system, utilizing the four-bar-link theory, presents a novel approach to studying OA levels 0 to 4. As OA progresses, the cartilage deteriorates, affecting the movement of OA. The OA-based knee measurement system that incorporates soft tissues and skeletons can assist in developing a personalized diagnostic approach for knee disease. This will also help to enhance surgical effectiveness by facilitating the creation of personalized prosthetic joints for individual patients and offering a customized surgical simulation.
Collapse
Affiliation(s)
- Minchae Kang
- Department of Mechanical Engineering, Advanced Manufacturing & Soft Robotics Lab, Dongguk University, 30 Pildong-ro 1, Jung-gu, Seoul 04620, Republic of Korea
| | - Suyeon Seo
- Department of Mechanical Engineering, Advanced Manufacturing & Soft Robotics Lab, Dongguk University, 30 Pildong-ro 1, Jung-gu, Seoul 04620, Republic of Korea
| | - Hyewon Lee
- Department of Mechanical, Robotics and Energy Engineering, Advanced Manufacturing & Soft Robotics Lab, Dongguk University, 30 Pildong-ro 1, Jung-gu, Seoul 04620, Republic of Korea
| | - Min-Woo Han
- Department of Mechanical Engineering, Advanced Manufacturing & Soft Robotics Lab, Dongguk University, 30 Pildong-ro 1, Jung-gu, Seoul 04620, Republic of Korea
- Department of Mechanical, Robotics and Energy Engineering, Advanced Manufacturing & Soft Robotics Lab, Dongguk University, 30 Pildong-ro 1, Jung-gu, Seoul 04620, Republic of Korea
| |
Collapse
|
12
|
Druel J, Gelin N, Ollivier M, Roseren F, Chabrand P, Jacquet C, Argenson JNA. Outcomes of Short and Long Tibial Stems for Primary Total Knee Arthroplasty in a Population of Obese Patients at Two-Year Follow-Up: A Clinical and Biomechanical Study. J Arthroplasty 2024:S0883-5403(24)00146-3. [PMID: 38401608 DOI: 10.1016/j.arth.2024.02.047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 02/06/2024] [Accepted: 02/11/2024] [Indexed: 02/26/2024] Open
Abstract
BACKGROUND Obesity can be a source of higher failure rates and inferior clinical outcomes after total knee arthroplasty (TKA). The aim of this study was to compare outcomes, failure rates, and stress distributions of TKA in obese patients using a short, long, or no tibial stem. METHODS A matching process based on the type of stem used and the age allowed included 180 patients who had a body mass index (BMI) > 30 and underwent a TKA between January 2010 and December 2019, with a minimum follow-up of 2 years. They were classified as moderately obese (MO: 30 < BMI < 35, N = 90) and severely obese (SO: BMI > 35, N = 90). For each, 3 subgroups were defined: thirty patients received a 30 mm short stem (SS), thirty received a 100 mm long stem (LS), and thirty received no stem (NS). Patients were assessed preoperatively and postoperatively using the Knee Society Score (KSS). A finite element model was developed to evaluate the biomechanical effects of the tibial stem on stress distribution in the subchondral bone based on BMI. RESULTS The SS patients had significantly higher postoperative KSS knee score [MO: 88.9 (SS) versus 79 (LS) versus 80.6 (NS); SO: 84.5 versus 72.4 versus 78.2] (P < .0001) and function score [MO: 90.4 (SS) versus 78.4 (LS) versus 68.5 (NS); SO: 85.5 versus 73 versus 61.8] (P < .0001) compared to LS and NS patients. The biomechanical study demonstrated a BMI-dependent increase in stress in the subchondral bone in contact with the tibial components. These stresses were mainly distributed at the tibial cut for NS and along the stem for SS and LS. CONCLUSIONS A short, cemented tibial stem offers better functional outcomes without increasing failure rates compared to a longer stem during primary TKA in a population of obese patients at two-year follow-up. A short tibial stem does not lead to increased stress compared to an LS, at least for certain BMI categories.
Collapse
Affiliation(s)
- Julien Druel
- Department of Orthopedic Surgery, Institute for Locomotion, Aix-Marseille University, Marseille, France; Department of Biomechanics, Aix-Marseille University, APHM, CNRS, ISM, St Marguerite Hospital, Institute for Locomotion, Marseille, France
| | - Nolwenn Gelin
- Department of Biomechanics, Aix-Marseille University, APHM, CNRS, ISM, St Marguerite Hospital, Institute for Locomotion, Marseille, France
| | - Matthieu Ollivier
- Department of Orthopedic Surgery, Institute for Locomotion, Aix-Marseille University, Marseille, France; Department of Biomechanics, Aix-Marseille University, APHM, CNRS, ISM, St Marguerite Hospital, Institute for Locomotion, Marseille, France
| | - Flavy Roseren
- Department of Biomechanics, Aix-Marseille University, APHM, CNRS, ISM, St Marguerite Hospital, Institute for Locomotion, Marseille, France
| | - Patrick Chabrand
- Department of Biomechanics, Aix-Marseille University, APHM, CNRS, ISM, St Marguerite Hospital, Institute for Locomotion, Marseille, France
| | - Christophe Jacquet
- Department of Orthopedic Surgery, Institute for Locomotion, Aix-Marseille University, Marseille, France; Department of Biomechanics, Aix-Marseille University, APHM, CNRS, ISM, St Marguerite Hospital, Institute for Locomotion, Marseille, France
| | - Jean-Noel A Argenson
- Department of Orthopedic Surgery, Institute for Locomotion, Aix-Marseille University, Marseille, France; Department of Biomechanics, Aix-Marseille University, APHM, CNRS, ISM, St Marguerite Hospital, Institute for Locomotion, Marseille, France
| |
Collapse
|
13
|
Gengatharan D, Saggi SS, Bin Abd Razak HR. Pre-operative Planning of High Tibial Osteotomy With ChatGPT: Are We There Yet? Cureus 2024; 16:e54858. [PMID: 38533173 PMCID: PMC10964394 DOI: 10.7759/cureus.54858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/23/2024] [Indexed: 03/28/2024] Open
Abstract
INTRODUCTION ChatGPT (Chat Generative Pre-trained Transformer), developed by OpenAI (San Francisco, CA, USA), has gained attention in the medical field. It has the potential to enhance and simplify tasks, such as preoperative planning in orthopedic surgery. We aimed to test ChatGPT's accuracy in measuring the angle of correction for high tibial osteotomy for cases planned and performed at a tertiary teaching hospital in Singapore. MATERIALS AND METHODS Peri-operative angular parameters from 114 consecutive patients who underwent medial opening wedge high tibial osteotomy (MOWHTO) were used to query ChatGPT 3.0. First ChatGPT 3.0 was queried on what information it required to plan a MOWHTO. Based on its response, pre-operative medial proximal tibial angle (MPTA) and joint line congruence angle (JLCA) were provided. ChatGPT 3.0 then responded with its recommended angle of correction. This was compared against the manually planned surgical correction by our fellowship-trained surgeon. A root mean square analysis was then performed to compare ChatGPT 3.0 and manual planning. RESULTS The root mean square error (RMSE) of ChatGPT 3.0 in predicting correction angle in MWHTO was 2.96, suggesting a very poor model fit. CONCLUSION Although ChatGPT 3.0 represents a significant breakthrough in large language models with extensive capabilities, it is not currently optimized to effectively perform complex pre-operative planning in orthopedic surgery, specifically in the context of MOWHTO. Further refinement and consideration of specific factors are necessary to enhance its accuracy and suitability for such applications.
Collapse
Affiliation(s)
| | | | - Hamid Rahmatullah Bin Abd Razak
- Musculoskeletal Sciences, Duke-Nus Medical School, Singapore, SGP
- Orthopaedic Surgery, Sengkang General Hospital, Singapore, SGP
| |
Collapse
|
14
|
Uzuner S, Li LP. Alteration in ACL loading after total and partial medial meniscectomy. BMC Musculoskelet Disord 2024; 25:94. [PMID: 38273316 DOI: 10.1186/s12891-024-07201-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 01/12/2024] [Indexed: 01/27/2024] Open
Abstract
Anterior cruciate ligament (ACL) injuries are often caused by high impact loadings during competitive sports but may also happen during regular daily activities due to tissue degeneration or altered mechanics after a previous knee injury or surgery such as meniscectomy. Most existing research on ACL injury has focused on impact loading scenarios or the consequence of ACL injury on meniscus. The objective of the present study was to investigate the effects of varying degrees of medial meniscectomy on the mechanics of intact ACL by performing a poromechanical finite element analysis under moderate creep loadings. Four clinical scenarios with 25%, 50%, 75% and total medial meniscectomy were compared with the intact knee finite element model. Our results suggested that different medial meniscal resections may increase, at different extents, the knee laxity and peak tensile stress in the ACL, potentially leading to collagen fiber fatigue tearing and altered mechanobiology under normal joint loadings. Interestingly, the ACL stress actually increased during early knee creep (~ 3 min) before it reached an equilibrium. In addition, meniscectomy accelerated ACL stress reduction during knee creep, transferred more loading to tibial cartilage, increased contact pressure, and shifted the contact center posteriorly. This study may contribute to a better understanding of the interaction of meniscectomy and ACL integrity during daily loadings.
Collapse
Affiliation(s)
- S Uzuner
- Department of Mechatronics, Faculty of Engineering, University of Duzce, Konuralp Campus, 81620, Duzce, Marmara, Türkiye.
| | - L P Li
- Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive, N.W, Calgary, AB, T2N 1N4, Canada
| |
Collapse
|
15
|
Jahn J, Ehlen QT, Huang CY. Finding the Goldilocks Zone of Mechanical Loading: A Comprehensive Review of Mechanical Loading in the Prevention and Treatment of Knee Osteoarthritis. Bioengineering (Basel) 2024; 11:110. [PMID: 38391596 PMCID: PMC10886318 DOI: 10.3390/bioengineering11020110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2023] [Revised: 01/15/2024] [Accepted: 01/18/2024] [Indexed: 02/24/2024] Open
Abstract
In this review, we discuss the interaction of mechanical factors influencing knee osteoarthritis (KOA) and post-traumatic osteoarthritis (PTOA) pathogenesis. Emphasizing the importance of mechanotransduction within inflammatory responses, we discuss its capacity for being utilized and harnessed within the context of prevention and rehabilitation of osteoarthritis (OA). Additionally, we introduce a discussion on the Goldilocks zone, which describes the necessity of maintaining a balance of adequate, but not excessive mechanical loading to maintain proper knee joint health. Expanding beyond these, we synthesize findings from current literature that explore the biomechanical loading of various rehabilitation exercises, in hopes of aiding future recommendations for physicians managing KOA and PTOA and athletic training staff strategically planning athlete loads to mitigate the risk of joint injury. The integration of these concepts provides a multifactorial analysis of the contributing factors of KOA and PTOA, in order to spur further research and illuminate the potential of utilizing the body's own physiological responses to mechanical stimuli in the management of OA.
Collapse
Affiliation(s)
- Jacob Jahn
- University of Miami Miller School of Medicine, Miami, FL 33136, USA
| | - Quinn T Ehlen
- University of Miami Miller School of Medicine, Miami, FL 33136, USA
| | - Chun-Yuh Huang
- Department of Biomedical Engineering, College of Engineering, University of Miami, Coral Gables, FL 33146, USA
| |
Collapse
|
16
|
Bender A, Schmidt H, Wellner DL, Duda GN, Brandl C, Damm P. In vivo load on knee, hip and spine during manual materials handling with two lifting techniques. J Biomech 2024; 163:111963. [PMID: 38286711 DOI: 10.1016/j.jbiomech.2024.111963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 01/19/2024] [Accepted: 01/22/2024] [Indexed: 01/31/2024]
Abstract
It is generally accepted that the lifting technique strongly influences physical loads within the human body and, thus, the risk of musculoskeletal disorders. However, there is a lack of knowledge regarding whether particular lifting techniques are effective in reducing loads. Hence, this retrospective study quantified (partly published) in vivo loads at joints within the human body during two typical lifting techniques, stoop lifting and squat lifting. Patients who had received instrumented implants underwent in vivo load measurements at either the knee (two patients), the hip (eight patients), or the upper lumbar spine (four patients) while lifting a 10 kg weight frontally with either straight (stoop) or bent (squat) knees. Contact forces and moments and the orientation of the contact force vector were determined and examined using the paired t test of Statistical Parametric Mapping. The two lifting techniques did not differ in terms of load magnitudes but did differ in terms of directions: (i) at the hip joint, the load vector varied significantly (p < 0.05) in the frontal and sagittal planes, (ii) at the knee joint, the load vector differed significantly (p < 0.05) in the sagittal plane (iii) while the load vector and magnitude did not differ at the upper lumbar spine (p > 0.05). Our findings indicate that the lifting technique causes changes in the orientation rather than the magnitude of lower extremity joint contact loads. Even though this quantification could only be performed in a small group of patients, the quantification of the relevance of such lifting technique recommendations will hopefully guide future recommendations towards a more scientific interpretation.
Collapse
Affiliation(s)
- Alwina Bender
- Julius Wolff Institute, Berlin Institute of Health at Charité, Charité - Universitätsmedizin Berlin, Germany
| | - Hendrik Schmidt
- Julius Wolff Institute, Berlin Institute of Health at Charité, Charité - Universitätsmedizin Berlin, Germany
| | - Daniela L Wellner
- Julius Wolff Institute, Berlin Institute of Health at Charité, Charité - Universitätsmedizin Berlin, Germany
| | - Georg N Duda
- Julius Wolff Institute, Berlin Institute of Health at Charité, Charité - Universitätsmedizin Berlin, Germany
| | - Christopher Brandl
- Institute of Industrial Engineering and Ergonomics, RWTH Aachen University, Aachen, Germany; Fraunhofer Institute for Communication, Information Processing and Ergonomics FKIE, Aachen, Germany
| | - Philipp Damm
- Julius Wolff Institute, Berlin Institute of Health at Charité, Charité - Universitätsmedizin Berlin, Germany.
| |
Collapse
|
17
|
Zhou S, Bender A, Kutzner I, Dymke J, Maleitzke T, Perka C, Duda GN, Winkler T, Damm P. Loading of the Hip and Knee During Swimming: An in Vivo Load Study. J Bone Joint Surg Am 2023; 105:1962-1971. [PMID: 38079507 DOI: 10.2106/jbjs.23.00218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2023]
Abstract
BACKGROUND Swimming is commonly recommended as postoperative rehabilitation following total hip arthroplasty (THA) and total knee arthroplasty (TKA). So far, in vivo hip and knee joint loads during swimming remain undescribed. METHODS In vivo hip and knee joint loads were measured in 6 patients who underwent THA and 5 patients who underwent TKA with instrumented joint implants. Joint loads, including the resultant joint contact force (F Res ), torsional moment around the femoral shaft axis or the tibial axis (M Tors ), bending moment at the middle of the femoral neck (M Bend ), torsional moment around the femoral neck axis (M Tne ), and medial force ratio (MFR) in the knee, were measured during breaststroke swimming at 0.5, 0.6, and 0.7 m/s and the breaststroke and crawl kicks at 0.5 and 1.0 m/s. RESULTS The ranges of the median maximal F Res were 157% to 193% of body weight for the hip and 93% to 145% of body weight for the knee during breaststroke swimming. Greater maxima of F Res (hip and knee), M Tors (hip and knee), M Bend (hip), and M Tne (hip) were observed with higher breaststroke swimming velocities, but significance was only identified between 0.5 and 0.6 m/s in F Res (p = 0.028), M Tors (p = 0.028), and M Bend (p = 0.028) and between 0.5 and 0.7 m/s in F Res (p = 0.045) in hips. No difference was found in maximal MFR between different breaststroke swimming velocities. The maximal F Res was significantly positively correlated with the breaststroke swimming velocity (hip: r = 0.541; p < 0.05; and knee: r = 0.414; p < 0.001). The maximal F Res (hip and knee) and moments (hip) were higher in the crawl kick than in the breaststroke kick, and a significant difference was recognized in F Res Max for the hip: median, 179% versus 118% of body weight (p = 0.028) for 0.5 m/s and 166% versus 133% of body weight (p = 0.028) for 1.0 m/s. CONCLUSIONS Swimming is a safe and low-impact activity, particularly recommended for patients who undergo THA or TKA. Hip and knee joint loads are greater with higher swimming velocities and can be influenced by swimming styles. Nevertheless, concrete suggestions to patients who undergo arthroplasty on swimming should involve individual considerations. LEVEL OF EVIDENCE Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Sijia Zhou
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
- Berlin Brandenburg Center for Regenerative Therapies, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Alwina Bender
- Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Ines Kutzner
- Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Jörn Dymke
- Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Tazio Maleitzke
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
- Berlin Institute of Health Charité Clinician Scientist Program, BIH Biomedical Innovation Academy, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Carsten Perka
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Georg N Duda
- Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
- Berlin Brandenburg Center for Regenerative Therapies, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Tobias Winkler
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
- Berlin Brandenburg Center for Regenerative Therapies, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Philipp Damm
- Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
18
|
Febrer-Nafría M, Dreyer MJ, Maas A, Taylor WR, Smith CR, Hosseini Nasab SH. Knee kinematics are primarily determined by implant alignment but knee kinetics are mainly influenced by muscle coordination strategy. J Biomech 2023; 161:111851. [PMID: 37907050 DOI: 10.1016/j.jbiomech.2023.111851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 10/19/2023] [Accepted: 10/22/2023] [Indexed: 11/02/2023]
Abstract
Implant malalignment has been reported to be a primary reason for revision total knee arthroplasty (TKA). In addition, altered muscle coordination patterns are commonly observed in TKA patients, which is thought to alter knee contact loads. A comprehensive understanding of the influence of surgical implantation and muscle recruitment strategies on joint contact mechanics is crucial to improve surgical techniques, increase implant longevity, and inform rehabilitation protocols. In this study, a detailed musculoskeletal model with a 12 degrees of freedom knee was developed to represent a TKA subject from the CAMS-Knee datasets. Using motion capture and ground reaction force data, a level walking cycle was simulated and the joint movement and loading patterns were estimated using a novel technique for concurrent optimization of muscle activations and joint kinematics. In addition, over 12'000 Monte Carlo simulations were performed to predict knee contact mechanics during walking, considering numerous combinations of implant alignment and muscle activation scenarios. Validation of our baseline simulation showed good agreement between the model kinematics and loading patterns against the in vivo data. Our analyses reveal a considerable impact of implant alignment on the joint kinematics, while variation in muscle activation strategies mainly affects knee contact loading. Moreover, our results indicate that high knee compressive forces do not necessarily originate from extreme kinematics and vice versa. This study provides an improved understanding of the complex inter-relationships between loading and movement patterns resulting from different surgical implantation and muscle coordination strategies and presents a validated framework towards population-based modelling in TKA.
Collapse
Affiliation(s)
- Míriam Febrer-Nafría
- Institute for Biomechanics, ETH Zürich, Switzerland; Department of Mechanical Engineering, Universitat Politècnica de Catalunya, Spain
| | - Michael J Dreyer
- Institute for Biomechanics, ETH Zürich, Switzerland; Laboratory for Mechanical Systems Engineering, Empa, Dübendorf, Switzerland
| | - Allan Maas
- Department of Orthopaedic and Trauma Surgery, Ludwig Maximilians University Munich, Musculoskeletal University Center Munich (MUM), Campus Grosshadern, Munich, Germany; Research and Development, Aesculap AG, Tuttlingen, Germany
| | | | - Colin R Smith
- Institute for Biomechanics, ETH Zürich, Switzerland; Steadman Philippon Research Institute, Vail, USA
| | | |
Collapse
|
19
|
Jones BW, Willson JD, DeVita P, Wedge RD. Tibiofemoral Load Magnitude and Distribution During Load Carriage. J Appl Biomech 2023; 39:432-439. [PMID: 37739402 DOI: 10.1123/jab.2022-0257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 07/26/2023] [Accepted: 08/02/2023] [Indexed: 09/24/2023]
Abstract
Chronic exposure to high tibiofemoral joint (TFJ) contact forces can be detrimental to knee joint health. Load carriage increases TFJ contact forces, but it is unclear whether medial and lateral tibiofemoral compartments respond similarly to incremental load carriage. The purpose of our study was to compare TFJ contact forces when walking with 15% and 30% added body weight. Young healthy adults (n = 24) walked for 5 minutes with no load, 15% load, and 30% load on an instrumented treadmill. Total, medial, and lateral TFJ contact peak forces and impulses were calculated via an inverse dynamics informed musculoskeletal model. Results of 1-way repeated measures analyses of variance (α = .05) demonstrated total, medial, and lateral TFJ first peak contact forces and impulses increased significantly with increasing load. Orthogonal polynomial trends demonstrated that the 30% loading condition led to a curvilinear increase in total and lateral TFJ impulses, whereas medial first peak TFJ contact forces and impulses responded linearly to increasing load. The total and lateral compartment impulse increased disproportionally with load carriage, while the medial did not. The medial and lateral compartments responded differently to increasing load during walking, warranting further investigation because it may relate to risk of osteoarthritis.
Collapse
Affiliation(s)
- Blake W Jones
- Department of Kinesiology, East Carolina University, Greenville, NC,USA
- Department of Physical Therapy, East Carolina University, Greenville, NC,USA
| | - John D Willson
- Department of Physical Therapy, East Carolina University, Greenville, NC,USA
| | - Paul DeVita
- Department of Kinesiology, East Carolina University, Greenville, NC,USA
| | - Ryan D Wedge
- Department of Physical Therapy, East Carolina University, Greenville, NC,USA
| |
Collapse
|
20
|
Voinier D, Neogi T, Master H, Thoma LM, Brunette M, Jakiela J, Stefanik JJ, White DK. Sitting may increase risk for radiographic incidence and progression of knee osteoarthritis over 2 years: Data from a large cohort study. Musculoskeletal Care 2023; 21:1075-1084. [PMID: 37253682 PMCID: PMC10687316 DOI: 10.1002/msc.1786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 05/12/2023] [Accepted: 05/16/2023] [Indexed: 06/01/2023]
Abstract
OBJECTIVES To examine the association of leisure-time sitting with radiographic incidence and progression of knee osteoarthritis (OA) over 2 years, and to determine whether worktime sitting modifies this association. METHODS We included adults with or at high risk for knee OA who enroled in the Osteoarthritis Initiative (OAI). Participants reported leisure-time sitting (≤4 vs. >4 h/day) and worktime sitting (frequent vs. infrequent) at enrolment, and had bilateral knee radiographs at enrolment and 2 years later. Our outcome, radiographic knee OA incidence/progression (yes/no), was defined as any increase in Kellgren-Lawrence grade over 2 years. We examined the association of leisure-time sitting (≤4 vs. >4 h/day) with risk of radiographic knee OA incidence/progression using binary linear regression, adjusting for potential confounders. We stratified by worktime sitting (frequent vs. infrequent) and repeated our analysis. RESULTS We included 4254 adults (mean age 61 years; 58% women; mean body mass index 29 kg/m2 ) who contributed a total of 8127 knees. Adults with >4 h/day of leisure-time sitting had 25% higher risk (adjusted risk ratio [RR] 1.25, 95% confidence interval [95% CI] 1.08-1.50) for radiographic knee OA incidence/progression compared with adults with ≤4 h/day of leisure-time sitting (referent group). Importantly, this association was intensified (RR 1.60, 95% CI 1.19-2.33) among adults with frequent worktime sitting, but was attenuated (RR 1.11, 95% CI 0.89-1.39) among adults with infrequent worktime sitting. CONCLUSIONS Higher leisure-time sitting (>4 h/day) may be associated with greater risk for radiographic knee OA incidence/progression over 2 years. Furthermore, this association was intensified among adults who also reported frequent worktime sitting.
Collapse
Affiliation(s)
- Dana Voinier
- Department of Physical Therapy, University of Delaware, Newark, Delaware, USA
| | - Tuhina Neogi
- Department of Medicine, Section of Rheumatology, Boston University School of Medicine, Boston, Massachusetts, USA
| | - Hiral Master
- Vanderbilt Institute for Clinical and Translational Research, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Louise M. Thoma
- Division of Physical Therapy, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | | | - Jason Jakiela
- Department of Physical Therapy, University of Delaware, Newark, Delaware, USA
| | - Joshua J. Stefanik
- Department of Physical Therapy, Movement and Rehabilitation Sciences, Northeastern University, Boston, Massachusetts, USA
| | - Daniel K. White
- Department of Physical Therapy, University of Delaware, Newark, Delaware, USA
| |
Collapse
|
21
|
Liu S, Amiri P, McGregor AH, Bull AMJ. Bilateral Asymmetry in Knee and Hip Musculoskeletal Loading During Stair Ascending/Descending in Individuals with Unilateral Mild-to-Moderate Medial Knee Osteoarthritis. Ann Biomed Eng 2023; 51:2490-2503. [PMID: 37482575 PMCID: PMC10598163 DOI: 10.1007/s10439-023-03289-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 06/19/2023] [Indexed: 07/25/2023]
Abstract
Most cases of unilateral knee osteoarthritis (OA) progress to bilateral OA within 10 years. Biomechanical asymmetries have been implicated in contralateral OA development; however, gait analysis alone does not consistently detect asymmetries in OA patient gait. Stair ambulation is a more demanding activity that may be more suited to reveal between-leg asymmetries in OA patients. The objective of this study was to investigate the between-leg biomechanical differences in patients with unilateral mild-to-moderate knee OA. Sixteen unilateral mild-to-moderate medial knee OA patients and 16 healthy individuals underwent kinematic and kinetic analysis of stair ascent and descent. Stair ascent produced higher loading and muscle forces in the unaffected limb compared to the OA limb, and stair descent produced lower loading on the OA limb compared to healthy subjects. These biomechanical differences were apparent in the ankle, knee, and hip joints. The implications of these findings are that OA patients rely more heavily on their unaffected sides than the affected side in stair ascent, a strategy that may be detrimental to the unaffected joint health. The reduction in affected limb loading in stair descent is thought to be related to minimizing pain.
Collapse
Affiliation(s)
- Sirui Liu
- Department of Bioengineering, Imperial College London, Sir Michael Uren Hub, Imperial College London White City Campus, 86 Wood Ln, London, W12 0BZ, UK.
| | - Pouya Amiri
- Department of Bioengineering, Imperial College London, Sir Michael Uren Hub, Imperial College London White City Campus, 86 Wood Ln, London, W12 0BZ, UK
| | - Alison H McGregor
- Department of Surgery and Cancer, Imperial College London, Sir Michael Uren Hub, Imperial College London White City Campus, 86 Wood Ln, London, W12 0BZ, UK
| | - Anthony M J Bull
- Department of Bioengineering, Imperial College London, Sir Michael Uren Hub, Imperial College London White City Campus, 86 Wood Ln, London, W12 0BZ, UK
| |
Collapse
|
22
|
Küpper JC, Kline A, Felfeliyan B, Jaremko J, Ronsky JL. Comparison of Dynamic Knee Contact Mechanics with T 2 Imaging in Different Ages of Healthy Participants. Ann Biomed Eng 2023; 51:2465-2478. [PMID: 37340276 DOI: 10.1007/s10439-023-03277-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 06/07/2023] [Indexed: 06/22/2023]
Abstract
Aging is a known risk factor for Osteoarthritis (OA), however, relations between cartilage composition and aging remain largely unknown in understanding human OA. T2 imaging provides an approach to assess cartilage composition. Whether these T2 relaxation times in the joint contact region change with time during gait remain unexplored. The study purpose was to demonstrate a methodology for linking dynamic joint contact mechanics to cartilage composition as measured by T2 relaxometry. T2 relaxation times for unloaded cartilage were measured in a 3T General Electric magnetic resonance (MR) scanner in this preliminary study. High-speed biplanar video-radiography (HSBV) was captured for five 20-30-year-old and five 50-60-year-old participants with asymptomatic knees. By mapping the T2 cartilages to the dynamic contact regions, T2 values were averaged over the contact area at each measurement within the gait cycle. T2 values demonstrated a functional relationship across the gait cycle. There were no statistically significant differences between 20- and 30-year-old and 50-60-year-old participant T2 values at first force peak of the gait cycle in the medial femur (p = 1.00, U = 12) or in the medial tibia (p = 0.31, U = 7). In the medial and lateral femur in swing phase, the joint moved from a region of high T2 values at 75% of gait to a minimum at 85-95% of swing. The lateral femur and tibia demonstrated similar patterns to the medial compartments but were less pronounced. This research advances understanding of the linkage between cartilage contact and cartilage composition. The change from a high T2 value at ~ 75% of gait to a lower value near the initiation of terminal swing (90% gait) indicates that there are changes to T2 averages corresponding to changes in the contact region across the gait cycle. No differences were found between age groups for healthy participants. These preliminary findings provide interesting insights into the cartilage composition corresponding to dynamic cyclic motion and inform mechanisms of osteoarthritis.
Collapse
Affiliation(s)
- Jessica Christine Küpper
- Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada.
- McCaig Institute for Bone and Joint Health, University of Calgary, 3280 Hospital Drive NW, Calgary, AB, T2N 4Z6, Canada.
| | - Adrienne Kline
- McCaig Institute for Bone and Joint Health, University of Calgary, 3280 Hospital Drive NW, Calgary, AB, T2N 4Z6, Canada
- Department of Biomedical Engineering, University of Calgary, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada
| | - Banafshe Felfeliyan
- McCaig Institute for Bone and Joint Health, University of Calgary, 3280 Hospital Drive NW, Calgary, AB, T2N 4Z6, Canada
- Department of Biomedical Engineering, University of Calgary, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada
| | - Jacob Jaremko
- Department of Radiology & Diagnostic Imaging, Faculty of Medicine, University of Alberta, Walter C MacKenzie Health Sciences Centre, 8440 112 Street NW, Edmonton, AB, T6G 2B7, Canada
| | - Janet L Ronsky
- Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, 3280 Hospital Drive NW, Calgary, AB, T2N 4Z6, Canada
- Department of Biomedical Engineering, University of Calgary, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada
| |
Collapse
|
23
|
Heyland M, Deppe D, Reisener MJ, Damm P, Taylor WR, Reinke S, Duda GN, Trepczynski A. Lower-limb internal loading and potential consequences for fracture healing. Front Bioeng Biotechnol 2023; 11:1284091. [PMID: 37901836 PMCID: PMC10602681 DOI: 10.3389/fbioe.2023.1284091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Accepted: 10/02/2023] [Indexed: 10/31/2023] Open
Abstract
Introduction: Mechanical loading is known to determine the course of bone fracture healing. We hypothesise that lower limb long bone loading differs with knee flexion angle during walking and frontal knee alignment, which affects fracture healing success. Materials and methods: Using our musculoskeletal in silico modelling constrained against in vivo data from patients with instrumented knee implants allowed us to assess internal loads in femur and tibia. These internal forces were associated with the clinical outcome of fracture healing in a relevant cohort of 178 extra-articular femur and tibia fractures in patients using a retrospective approach. Results: Mean peak forces differed with femoral compression (1,330-1,936 N at mid-shaft) amounting to about half of tibial compression (2,299-5,224 N). Mean peak bending moments in the frontal plane were greater in the femur (71-130 Nm) than in the tibia (from 26 to 43 Nm), each increasing proximally. Bending in the sagittal plane showed smaller mean peak bending moments in the femur (-38 to 43 Nm) reaching substantially higher values in the tibia (-63 to -175 Nm) with a peak proximally. Peak torsional moments had opposite directions for the femur (-13 to -40 Nm) versus tibia (15-48 Nm) with an increase towards the proximal end in both. Femoral fractures showed significantly lower scores in the modified Radiological Union Scale for Tibia (mRUST) at last follow-up (p < 0.001) compared to tibial fractures. Specifically, compression (r = 0.304), sagittal bending (r = 0.259), and frontal bending (r = -0.318) showed strong associations (p < 0.001) to mRUST at last follow-up. This was not the case for age, body weight, or localisation alone. Discussion: This study showed that moments in femur and tibia tend to decrease towards their distal ends. Tibial load components were influenced by knee flexion angle, especially at push-off, while static frontal alignment played a smaller role. Our results indicate that femur and tibia are loaded differently and thus require adapted fracture fixation considering load components rather than just overall load level.
Collapse
Affiliation(s)
- Mark Heyland
- Julius Wolff Institute, Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Berlin, Germany
| | - Dominik Deppe
- Julius Wolff Institute, Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Berlin, Germany
- Department of Radiology, Charité—Universitätsmedizin Berlin, Berlin, Germany
| | - Marie Jacqueline Reisener
- Julius Wolff Institute, Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Berlin, Germany
- Centre for Muskuloskeletal Surgery (CMSC), Charité—Universitätsmedizin Berlin, Berlin, Germany
| | - Philipp Damm
- Julius Wolff Institute, Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Berlin, Germany
| | - William R. Taylor
- Laboratory for Movement Biomechanics, ETH Zürich, Zürich, Switzerland
| | - Simon Reinke
- Julius Wolff Institute, Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Berlin, Germany
| | - Georg N. Duda
- Julius Wolff Institute, Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Berlin, Germany
| | - Adam Trepczynski
- Julius Wolff Institute, Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
24
|
Hashizume T, Ishii Y, Nakashima Y, Okamoto S, Iwamoto Y, Okada K, Takagi K, Adachi N, Takahashi M. Evaluation of meniscus extrusion during stair ambulation in healthy volunteers using dynamic ultrasonography: a feasibility study. J Med Ultrason (2001) 2023; 50:541-549. [PMID: 37566159 PMCID: PMC10912121 DOI: 10.1007/s10396-023-01348-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 07/03/2023] [Indexed: 08/12/2023]
Abstract
PURPOSE This study aimed to investigate the feasibility of evaluating medial meniscus extrusion (MME) during stair ambulation. METHODS Twenty healthy young participants (mean age, 22.4 ± 0.9 years) were recruited for this cross-sectional study. Synchronization between the three-dimensional motion system and ultrasonography was used to quantify the extent of meniscal extrusion and knee angles during different tasks, including gait, stair ascent, and stair descent. In particular, ultrasonography was used to record the movements of both the middle and posterior segments of the meniscus to obtain detailed information about these movements in relation to the knee angle. The difference between the maximum MME and the MME at the initial contact (ΔMME) was evaluated during each task in the stance phase. RESULTS Visualization of the meniscus in the middle segment was limited with increasing knee flexion angle, whereas the posterior segments were visible during all tasks. ΔMME of the posterior segment during stair ascent and descent was higher than that during gait (gait: 0.68 ± 0.20 mm, ascent: 1.00 ± 0.39 mm, descent: 0.90 ± 0.27 mm, gait-ascent: p = 0.009, gait-descent: p = 0.004). CONCLUSIONS Evaluation that includes the posterior segment enables visualization of the medial meniscus and detection of its specific behavior during stair ambulation. These findings demonstrate the feasibility of evaluating meniscus dynamics during stair ambulation, and could contribute to a better understanding of these dynamics.
Collapse
Affiliation(s)
- Takato Hashizume
- Department of Biomechanics, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8553, Japan
| | - Yosuke Ishii
- Department of Biomechanics, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8553, Japan.
| | - Yuko Nakashima
- Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Saeko Okamoto
- Department of Biomechanics, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8553, Japan
| | - Yoshitaka Iwamoto
- Department of Biomechanics, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8553, Japan
| | - Kaoru Okada
- Ultrasound Business Operations, Healthcare Business Headquarters, Konica Minolta, Inc, Tokyo, Japan
| | - Kazuya Takagi
- Ultrasound Business Operations, Healthcare Business Headquarters, Konica Minolta, Inc, Tokyo, Japan
| | - Nobuo Adachi
- Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Makoto Takahashi
- Department of Biomechanics, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8553, Japan
| |
Collapse
|
25
|
Paz A, García JJ, Korhonen RK, Mononen ME. Towards a Transferable Modeling Method of the Knee to Distinguish Between Future Healthy Joints from Osteoarthritic Joints: Data from the Osteoarthritis Initiative. Ann Biomed Eng 2023; 51:2192-2203. [PMID: 37284996 PMCID: PMC10518288 DOI: 10.1007/s10439-023-03252-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 05/22/2023] [Indexed: 06/08/2023]
Abstract
Computational models can be used to predict the onset and progression of knee osteoarthritis. Ensuring the transferability of these approaches among computational frameworks is urgent for their reliability. In this work, we assessed the transferability of a template-based modeling strategy, based on the finite element (FE) method, by implementing it on two different FE softwares and comparing their results and conclusions. For that, we simulated the knee joint cartilage biomechanics of 154 knees using healthy baseline conditions and predicted the degeneration that occurred after 8 years of follow-up. For comparisons, we grouped the knees using their Kellgren-Lawrence grade at the 8-year follow-up time and the simulated volume of cartilage tissue that exceeded age-dependent thresholds of maximum principal stress. We considered the medial compartment of the knee in the FE models and used ABAQUS and FEBio FE softwares for simulations. The two FE softwares detected different volumes of overstressed tissue in corresponding knee samples (p < 0.01). However, both programs correctly distinguished between the joints that remained healthy and those that developed severe osteoarthritis after the follow-up (AUC = 0.73). These results indicate that different software implementations of a template-based modeling method similarly classify future knee osteoarthritis grades, motivating further evaluations using simpler cartilage constitutive models and additional studies on the reproducibility of these modeling strategies.
Collapse
Affiliation(s)
- Alexander Paz
- Department of Technical Physics, University of Eastern Finland, Yliopistonranta 1, 70211, Kuopio, Finland.
- Escuela de Ingeniería Civil y Geomática, Universidad del Valle, Cali, Colombia.
| | - José J García
- Escuela de Ingeniería Civil y Geomática, Universidad del Valle, Cali, Colombia
| | - Rami K Korhonen
- Department of Technical Physics, University of Eastern Finland, Yliopistonranta 1, 70211, Kuopio, Finland
| | - Mika E Mononen
- Department of Technical Physics, University of Eastern Finland, Yliopistonranta 1, 70211, Kuopio, Finland
| |
Collapse
|
26
|
Wu H, Guo Y, Guo W. Effect of carbon-fiber-reinforced polyetheretherketone on stress distribution in a redesigned tumor-type knee prosthesis: a finite element analysis. Front Bioeng Biotechnol 2023; 11:1243936. [PMID: 37823023 PMCID: PMC10562634 DOI: 10.3389/fbioe.2023.1243936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Accepted: 09/11/2023] [Indexed: 10/13/2023] Open
Abstract
Background: Surgery for bone tumors around the knee often involves extensive resection, making the subsequent prosthetic reconstruction challenging. While carbon fiber-reinforced polyetheretherketone (CF-PEEK) has been widely used in orthopedic implants, its application in tumor-type prosthesis is limited. This study aims to evaluate the feasibility of using 30wt% and 60wt% carbon fiber-reinforced polyetheretherketone (CF30-PEEK and CF60-PEEK) as materials for a redesigned tumor-type knee prosthesis through numerical analysis. Methods: A knee joint model based on CT data was created, and the resection and prosthetic reconstruction were simulated. Three finite element models of the prostheses, representing the initial and updated designs with CoCrMo and CFR-PEEK components, were constructed. Loading conditions during standing and squatting were simulated with forces of 700 N and 2800 N, respectively. Finite element analysis was used to analyze the von Mises stress and stability of all components for each prosthesis type. Results: After improvements in both material and design, the new Type 3 prosthesis showed significantly lower overall stress with stress being evenly distributed. Compared with the initial design, the maximum von Mises stress in Type 3 was reduced by 53.9% during standing and 74.2% during squatting. In the standing position, the maximum stress in the CF30-PEEK femoral component decreased by 57.3% compared with the initial design which was composed of CoCrMo, while the stress in the CF60-PEEK cardan shaft remained consistent. In the squatting position, the maximum stress in the femoral component decreased by 81.9%, and the stress in the cardan shaft decreased by 46.5%. Conclusion: The incorporation of CF30-PEEK effectively transmits forces and reduces stress concentration on the femoral component, while CF60-PEEK in the redesigned cardan shaft significantly reduces stress while maintaining stiffness. The redesigned prosthesis effectively conducts loading force and demonstrates favorable biomechanical characteristics, indicating the promising potential of utilizing CF30-PEEK and CF60-PEEK materials for tumor-type knee prostheses. The findings of this study could provide novel insights for the design and development of tumor-type knee prostheses.
Collapse
Affiliation(s)
- Han Wu
- Department of Musculoskeletal Tumor, People’s Hospital, Peking University, Beijing, China
- Beijing Key Laboratory of Musculoskeletal Tumor, Beijing, China
| | - Yu Guo
- Department of Musculoskeletal Tumor, People’s Hospital, Peking University, Beijing, China
- Beijing Key Laboratory of Musculoskeletal Tumor, Beijing, China
| | - Wei Guo
- Department of Musculoskeletal Tumor, People’s Hospital, Peking University, Beijing, China
- Beijing Key Laboratory of Musculoskeletal Tumor, Beijing, China
| |
Collapse
|
27
|
Blasimann A, Busch A, Henle P, Bruhn S, Vissers D, Baur H. Neuromuscular control in males and females 1 year after an anterior cruciate ligament rupture or reconstruction during stair descent and artificial tibial translation. Sci Rep 2023; 13:15316. [PMID: 37714980 PMCID: PMC10504317 DOI: 10.1038/s41598-023-42491-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Accepted: 09/11/2023] [Indexed: 09/17/2023] Open
Abstract
Neuromuscular alterations are reported in patients with anterior cruciate ligament reconstruction (ACL-R) and conservative treatment (copers with ACL deficiency, ACL-C). However, it is unclear whether sex influences neuromuscular control. The objective was to investigate differences in neuromuscular control regarding sex and treatment type one year after ACL rupture in comparison to a group with an intact ACL (ACL-I). Electromyography of vastus medialis (VM) and lateralis, biceps femoris (BF) and semitendinosus (ST) was recorded in ACL-R (N = 38), ACL-C (N = 26), and ACL-I (N = 38) during stair descent and reflex activity by anterior tibial translation while standing. The movements of stair descent were divided into pre-activity, weight-acceptance and push-off phases, reflex activity in pre-activation, short, medium (MLR), and long latency responses (LLR). Normalized root mean squares for each muscle of involved and matched control limb per phase were calculated and analyzed with two-way ANOVA (α = 0.05). During stair descent, neuromuscular differences of BF were significant during push-off only (p = 0.001). Males of ACL-R and ACL-C had higher BF activity compared to ACL-I (p = 0.009, 0.007 respectively). During reflex activity, VM and BF were significantly different between treatment groups for pre-activation (p = 0.013, 0.035 respectively). VM pre-activation of females was higher in ACL-R compared to ACL-C (p = 0.018), and lower in ACL-C compared to ACL-I (p = 0.034). Males of ACL-R showed higher VM and less BF pre-activation (p = 0.025, p = 0.003 respectively) compared to ACL-I. Males of ACL-C had less BF pre-activation compared to ACL-I (p = 0.019). During MLR, intra-group differences in ST were found for treatment (p = 0.011) and females of ACL-R compared to ACL-I (p = 0.015). During LLR, overall intra-group differences in VM were present for treatment (p = 0.034) and in females (ACL-R versus ACL-C (p = 0.015), ACL-I (p = 0.049), respectively). One year after an ACL rupture, neuromuscular alterations persist regardless of treatment and sex. Standard rehabilitation protocols may not be able to restore neuromuscular control. Future research should include long-term follow up and focus on exercises targeting neuromuscular function.
Collapse
Affiliation(s)
- Angela Blasimann
- Division of Physiotherapy, School of Health Professions, Bern University of Applied Sciences, Bern, Switzerland.
- Department of Rehabilitation Sciences and Physiotherapy, Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium.
| | - Aglaja Busch
- Division of Physiotherapy, School of Health Professions, Bern University of Applied Sciences, Bern, Switzerland
- University Outpatient Clinic, Sports Medicine & Sports Orthopaedics, University of Potsdam, Potsdam, Germany
| | - Philipp Henle
- Sonnenhof Orthopaedic Center, Lindenhof Group AG, Bern, Switzerland
- Department of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Sven Bruhn
- Institute of Sports Science, University of Rostock, Rostock, Germany
| | - Dirk Vissers
- Department of Rehabilitation Sciences and Physiotherapy, Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium
| | - Heiner Baur
- Division of Physiotherapy, School of Health Professions, Bern University of Applied Sciences, Bern, Switzerland
| |
Collapse
|
28
|
Xue H, Deng J, Zhang Z, Knoedler S, Panayi AC, Knoedler L, Mi B, Liu M, Dai G, Liu G. Different internal fixation methods for Hoffa-like fractures of the tibial plateau: a finite element analysis. Front Med (Lausanne) 2023; 10:1172377. [PMID: 37465644 PMCID: PMC10351422 DOI: 10.3389/fmed.2023.1172377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 06/08/2023] [Indexed: 07/20/2023] Open
Abstract
Due to the low incidence of posteromedial tibial plateau fractures and limited clinical data available, the optimal treatment for this type of fracture remains to be established. This type of fracture, also known as Hoffa-like fracture of the tibial plateau, shares a similar mechanism of injury with the Hoffa fracture of the femoral condyle. In the field of orthopedics, finite element analysis is considered a valuable method to guide clinical decision-making. In this study, four methods used for internal fixation of Hoffa-like fractures of the tibial plateau were compared using computer simulation and applying a finite element method (FEM). The methods compared were lateral L-plate fixation alone (Model A); lateral L-plate combined with posterior anti-slip plate (reconstruction plate/T-plate) fixation (Model B); lateral L-plate combined with posterior hollow nail fixation of the fracture block (Model C); and lateral L-plate combined with anterior hollow nail fixation of the fracture (Model D). The maximum displacement of the model and the maximum stress of the internal fixation material were analyzed by applying an axial load of 2,500 N. The results showed that, in the normal bone model, the maximum displacement of the fracture in Model A was 0.60032 mm, with improved stability through the addition of posterior lateral plate fixation in Model B and reduction of the displacement to 0.38882 mm. The maximum displacement in Model C and Model D was comparable, amounting to 0.42345 mm and 0.42273 mm, respectively. Maximum stress was 1235.6 MPa for Model A, 84.724 MPa for Model B, 99.805 MPa for Model C, and 103.19 MPa for Model D. In the internal fixation analysis of the osteoporotic fracture model, we observed patterns similar to the results of the normal bone model. The results indicated that Model B yielded the overall best results in the treatment of Hoffa-like fractures of the tibial plateau. The orthopedic surgeon may wish to implement these insights into the perioperative algorithm, thereby refining and optimizing clinical patient care. In addition, our findings pave the way for future research efforts.
Collapse
Affiliation(s)
- Hang Xue
- Department of Orthopedics, Jingshan Union Hospital, Union Hospital, Huazhong University of Science and Technology, Wuhan, China
| | - Junrong Deng
- Department of Orthopedics, Jingshan Union Hospital, Union Hospital, Huazhong University of Science and Technology, Wuhan, China
| | - Zhenhe Zhang
- Department of Orthopedics, Jingshan Union Hospital, Union Hospital, Huazhong University of Science and Technology, Wuhan, China
| | - Samuel Knoedler
- Division of Plastic Surgery, Department of Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States
| | - Adriana C. Panayi
- Division of Plastic Surgery, Department of Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States
| | - Leonard Knoedler
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Bobin Mi
- Department of Orthopedics, Jingshan Union Hospital, Union Hospital, Huazhong University of Science and Technology, Wuhan, China
| | - Mengfei Liu
- Department of Orthopedics, Jingshan Union Hospital, Union Hospital, Huazhong University of Science and Technology, Wuhan, China
| | - Guandong Dai
- Pingshan District People’s Hospital of Shenzhen, Pingshan General Hospital of Southern Medical University, Shenzhen, China
| | - Guohui Liu
- Department of Orthopedics, Jingshan Union Hospital, Union Hospital, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
29
|
Bauer L, Woiczinski M, Thorwächter C, Müller PE, Holzapfel BM, Niethammer TR, Simon JM. Influence of kinematic alignment on femorotibial kinematics in medial stabilized TKA design compared to mechanical alignment. Arch Orthop Trauma Surg 2023; 143:4339-4347. [PMID: 36282314 PMCID: PMC10293425 DOI: 10.1007/s00402-022-04661-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 10/10/2022] [Indexed: 02/09/2023]
Abstract
INTRODUCTION Worldwide more and more primary knee replacements are being performed. Kinematic alignment (KA) as one of many methods of surgical alignment has been shown to have a significant impact on kinematics and function. The aim of the present study was to compare KA and mechanical alignment (MA) with regard to femorotibial kinematics. MATERIALS AND METHODS Eight fresh frozen human specimens were tested on a knee rig during active knee flexion from 30 to 130°. Within the same specimen a medial stabilized (MS) implant design was used first with KA and then with MA. RESULTS The femorotibial kinematics showed more internal rotation of the tibia in KA compared to MA. At the same time, there was a larger medial rotation point in KA. Both alignment methods showed femoral rollback over the knee bend. CONCLUSION Relating to an increased internal rotation and a more precise medial pivot point, it can be concluded that KA combined with a MS implant design may partially support the reproduction of physiological knee joint mechanics.
Collapse
Affiliation(s)
- L Bauer
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - M Woiczinski
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - C Thorwächter
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - P E Müller
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - B M Holzapfel
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - T R Niethammer
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - J-M Simon
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
| |
Collapse
|
30
|
Spencer A, Samaan M, Noehren B. Monitoring Knee Contact Force with Force-Sensing Insoles. SENSORS (BASEL, SWITZERLAND) 2023; 23:4900. [PMID: 37430813 DOI: 10.3390/s23104900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 04/22/2023] [Accepted: 05/06/2023] [Indexed: 07/12/2023]
Abstract
Numerous applications exist for monitoring knee contact force (KCF) throughout activities of daily living. However, the ability to estimate these forces is restricted to a laboratory setting. The purposes of this study are to develop KCF metric estimation models and explore the feasibility of monitoring KCF metrics via surrogate measures derived from force-sensing insole data. Nine healthy subjects (3F, age 27 ± 5 years, mass 74.8 ± 11.8 kg, height 1.7 ± 0.08 m) walked at multiple speeds (0.8-1.6 m/s) on an instrumented treadmill. Thirteen insole force features were calculated as potential predictors of peak KCF and KCF impulse per step, estimated with musculoskeletal modeling. The error was calculated with median symmetric accuracy. Pearson product-moment correlation coefficients defined the relationship between variables. Models develop per-limb demonstrated lower prediction error than those developed per-subject (KCF impulse: 2.2% vs 3.4%; peak KCF: 3.50% vs. 6.5%, respectively). Many insole features are moderately to strongly associated with peak KCF, but not KCF impulse across the group. We present methods to directly estimate and monitor changes in KCF using instrumented insoles. Our results carry promising implications for internal tissue loads monitoring outside of a laboratory with wearable sensors.
Collapse
Affiliation(s)
- Alex Spencer
- Department of Physical Therapy, College of Health Sciences, University of Kentucky, Lexington, KY 40508, USA
- Department of Kinesiology & Health Promotion, College of Education, University of Kentucky, Lexington, KY 40508, USA
- Department of Biomedical Engineering, College of Engineering, University of Kentucky, Lexington, KY 40508, USA
| | - Michael Samaan
- Department of Kinesiology & Health Promotion, College of Education, University of Kentucky, Lexington, KY 40508, USA
- Department of Biomedical Engineering, College of Engineering, University of Kentucky, Lexington, KY 40508, USA
- Department of Orthopedic Surgery and Sports Medicine, College of Medicine, University of Kentucky, Lexington, KY 40508, USA
| | - Brian Noehren
- Department of Physical Therapy, College of Health Sciences, University of Kentucky, Lexington, KY 40508, USA
- Department of Orthopedic Surgery and Sports Medicine, College of Medicine, University of Kentucky, Lexington, KY 40508, USA
| |
Collapse
|
31
|
Di Raimondo G, Willems M, Killen BA, Havashinezhadian S, Turcot K, Vanwanseele B, Jonkers I. Peak Tibiofemoral Contact Forces Estimated Using IMU-Based Approaches Are Not Significantly Different from Motion Capture-Based Estimations in Patients with Knee Osteoarthritis. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094484. [PMID: 37177688 PMCID: PMC10181595 DOI: 10.3390/s23094484] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/01/2023] [Accepted: 05/03/2023] [Indexed: 05/15/2023]
Abstract
Altered tibiofemoral contact forces represent a risk factor for osteoarthritis onset and progression, making optimization of the knee force distribution a target of treatment strategies. Musculoskeletal model-based simulations are a state-of-the-art method to estimate joint contact forces, but they typically require laboratory-based input and skilled operators. To overcome these limitations, ambulatory methods, relying on inertial measurement units, have been proposed to estimated ground reaction forces and, consequently, knee contact forces out-of-the-lab. This study proposes the use of a full inertial-capture-based musculoskeletal modelling workflow with an underlying probabilistic principal component analysis model trained on 1787 gait cycles in patients with knee osteoarthritis. As validation, five patients with knee osteoarthritis were instrumented with 17 inertial measurement units and 76 opto-reflective markers. Participants performed multiple overground walking trials while motion and inertial capture methods were synchronously recorded. Moderate to strong correlations were found for the inertial capture-based knee contact forces compared to motion capture with root mean square error between 0.15 and 0.40 of body weight. The results show that our workflow can inform and potentially assist clinical practitioners to monitor knee joint loading in physical therapy sessions and eventually assess long-term therapeutic effects in a clinical context.
Collapse
Affiliation(s)
- Giacomo Di Raimondo
- Department of Movement Sciences, Katholieke Universiteit Leuven, 3001 Heverlee, Belgium
| | - Miel Willems
- Department of Movement Sciences, Katholieke Universiteit Leuven, 3001 Heverlee, Belgium
| | - Bryce Adrian Killen
- Department of Movement Sciences, Katholieke Universiteit Leuven, 3001 Heverlee, Belgium
| | | | - Katia Turcot
- Department of Kinesiology, Université Laval, Québec, QC G1V 0A6, Canada
| | - Benedicte Vanwanseele
- Department of Movement Sciences, Katholieke Universiteit Leuven, 3001 Heverlee, Belgium
| | - Ilse Jonkers
- Department of Movement Sciences, Katholieke Universiteit Leuven, 3001 Heverlee, Belgium
| |
Collapse
|
32
|
Liang W, Wang F, Fan A, Zhao W, Yao W, Yang P. Extended Application of Inertial Measurement Units in Biomechanics: From Activity Recognition to Force Estimation. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094229. [PMID: 37177436 PMCID: PMC10180901 DOI: 10.3390/s23094229] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 04/20/2023] [Accepted: 04/22/2023] [Indexed: 05/15/2023]
Abstract
Abnormal posture or movement is generally the indicator of musculoskeletal injuries or diseases. Mechanical forces dominate the injury and recovery processes of musculoskeletal tissue. Using kinematic data collected from wearable sensors (notably IMUs) as input, activity recognition and musculoskeletal force (typically represented by ground reaction force, joint force/torque, and muscle activity/force) estimation approaches based on machine learning models have demonstrated their superior accuracy. The purpose of the present study is to summarize recent achievements in the application of IMUs in biomechanics, with an emphasis on activity recognition and mechanical force estimation. The methodology adopted in such applications, including data pre-processing, noise suppression, classification models, force/torque estimation models, and the corresponding application effects, are reviewed. The extent of the applications of IMUs in daily activity assessment, posture assessment, disease diagnosis, rehabilitation, and exoskeleton control strategy development are illustrated and discussed. More importantly, the technical feasibility and application opportunities of musculoskeletal force prediction using IMU-based wearable devices are indicated and highlighted. With the development and application of novel adaptive networks and deep learning models, the accurate estimation of musculoskeletal forces can become a research field worthy of further attention.
Collapse
Affiliation(s)
- Wenqi Liang
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Fanjie Wang
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Ao Fan
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Wenrui Zhao
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Wei Yao
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Pengfei Yang
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| |
Collapse
|
33
|
Wan Q, Zhang A, Liu Y, Chen H, Zhang J, Xue H, Han Q, Wang J. The influence of body weight index on initial stability of uncemented femoral knee protheses: A finite element study. Heliyon 2023; 9:e13819. [PMID: 36895366 PMCID: PMC9988490 DOI: 10.1016/j.heliyon.2023.e13819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Revised: 02/07/2023] [Accepted: 02/13/2023] [Indexed: 02/19/2023] Open
Abstract
Background and objective Obesity is one of the risk factors for osteoarthritis. The end-stage treatment for osteoarthritis is total knee arthroplasty (TKA). However, it remains controversial whether a high body mass index (BMI) affects the initial stability of the femoral prosthesis after TKA. Finite element analysis (FEA) was used to investigate this question in this study. Methods Four femur models that assembled with TKA femoral components were reconstructed and divided into high BMI group and normal BMI group. The three-dimensional femurs were modeled and assigned inhomogeneous materials based on computed tomography (CT) images. Then each FEA model was applied with gait and deep bend loading conditions to evaluate the maximum principal strain on the distal femur and the relative micromotion between the femur and prosthesis. Results The mean strain of the high BMI group increased by 32.7% (936.9 με versus 706.1 με) and 50.9% (2064.5 με versus 1368.2 με) under gait and deep bend loading conditions, respectively, compared to the normal BMI group. Meanwhile, the mean micromotion of the high BMI group increased by 41.6% (2.77 μm versus 1.96 μm) and 58.5% (62.1 μm versus 39.2 μm), respectively. Under gait condition, the maximum micromotion for high BMI group was 33.8 μm and would compromise the initial stability. Under deep bend condition, the maximum strain and micromotion exceeded -7300 με and 28 μm for both groups. Conclusion High BMI caused higher strain on the bone and higher micromotion between the prosthesis and the femur. Gait activities could be risky for prosthesis stability in high BMI group while be safe in normal group. Deep bend activities were highly dangerous for both groups with high BMI and normal BMI and should be avoided.
Collapse
Affiliation(s)
- Qian Wan
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Aobo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Yang Liu
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Hao Chen
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Jiangbo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Haowen Xue
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Qing Han
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Jincheng Wang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| |
Collapse
|
34
|
Li Q, Miramini S, Smith DW, Gardiner BS, Zhang L. Osteochondral junction leakage and cartilage joint lubrication. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 230:107353. [PMID: 36736148 DOI: 10.1016/j.cmpb.2023.107353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 12/08/2022] [Accepted: 01/12/2023] [Indexed: 06/18/2023]
Abstract
BACKGROUND AND OBJECTIVES Previous studies have shown that there is potentially interstitial fluid exchange between cartilage tissue and the subarticular spongiosa region in the case of injury or disease (e.g., osteoarthritis and osteoporosis). Interstitial flow is also required for cartilage lubrication under joint load. A key question then is how cartilage lubrication is modified by increased interstitial fluid leakage across the osteochondral junction. Thus, the purpose of this study is to develop a numerical model to investigate changes in cartilage lubrication with changes in osteochondral junction leakage. METHODS The multi-phase coupled model includes domains corresponding to the contact gap, cartilage tissue and subchondral bone plate region (ScBP). Each of these domains are treated as poroelastic systems, with their coupling implemented through mass and pressure continuity. The effects of osteochondral junction leakage on lubrication were investigated with a parametric study on the relative permeability between the ScBP and cartilage tissue. RESULTS Significant effects of ScBP permeability were predicted, especially during the early stage of the junction leakage development (early stage of the disease). There is a significant reduction in mixed-mode lubrication duration under the effect of increased junction leakage (the cartilage tissue mixed-mode lubrication duration is about 33% decrease for a relative permeability ratio of 0.1 between ScBP and cartilage tissue, and about 52% decrease under the osteoarthritis condition). In addition, the time for cartilage to reach steady-state consolidation is significantly reduced when ScBP permeability increases (the consolidation time reduces from roughly 2 h to 1.2 h when the relative permeability ratio increases from 0.001 to 0.1, and it reduces to 0.8 h for an advanced osteoarthritis condition). It is predicted that the initial friction coefficient could increase by over 60% when the ScBP permeability is consistent with an advanced osteoarthritis (OA) condition. CONCLUSION Increased osteochondral junction leakage induced by joint injury and disease could result in increased cartilage surface wear rates due to more rapid interstitial fluid depressurization within articular cartilage.
Collapse
Affiliation(s)
- Qin Li
- Department of Infrastructure Engineering, The University of Melbourne, VIC 3010, Australia
| | - Saeed Miramini
- Department of Infrastructure Engineering, The University of Melbourne, VIC 3010, Australia
| | - David W Smith
- School of Physics, Mathematics and Computing, The University of Western Australia, WA 6009, Australia
| | - Bruce S Gardiner
- Centre for Molecular Medicine and Innovative Therapeutics, Murdoch University, WA 6150, Australia
| | - Lihai Zhang
- Department of Infrastructure Engineering, The University of Melbourne, VIC 3010, Australia.
| |
Collapse
|
35
|
Park HJ, Chang MJ, Cho HJ, Hong E, Kim TW, Chang CB, Bae TS, Kwak DS, Kang SB. Medial Meniscus Posterior Root Repair Restores Contact Pressure and Contact Area to Its Native State Even After Opening-Wedge High Tibial Osteotomy: A Cadaveric Biomechanical Study. Arthroscopy 2023; 39:638-646. [PMID: 36191732 DOI: 10.1016/j.arthro.2022.09.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 08/30/2022] [Accepted: 09/09/2022] [Indexed: 02/07/2023]
Abstract
PURPOSE To elucidate the effect of medial meniscus posterior root (MMPR) repair during opening-wedge high tibial osteotomy (OWHTO) in terms of contact pressure (CP) and contact area (CA). METHODS Nine fresh-frozen human cadaveric knee specimens were included. Each specimen was tested under 9 conditions comprising 3 different degrees of correction during OWHTO (neutral, 5° of valgus, and 10° of valgus) and 3 different types of MMPR conditions (intact, torn, and repaired). The prepared specimens were attached to a customized tibiofemoral jig in a fully extended state. The CP and CA generated by a tibiofemoral axial load of 650 N was recorded using the Tekscan sensor's pressure mapping software. Statistical analysis was performed using a repeated measures analysis of variance. RESULTS The increased CP and decreased CA in torn MMPR was decreased and increased, respectively, to the intact MMPR after repairing, irrespective of whether OWHTO was performed. The mean CP at a correction angle of 5° of valgus was 0.4067 ± 0.0768 MPa for intact MMPR, which increased to 0.7340 ± 0.1593 MPa for the torn MMPR and decreased to 0.3614 ± 0.0639 MPa for the repaired MMPR. In addition, the proportion of decrease in CP and increase in CA after MMPR repair was constant, compared with the torn MMPR, irrespective of the degree of correction during OWHTO. CONCLUSIONS MMPR repair decreases CP and increases CA, irrespective of whether OWHTO is performed. The biomechanical advantage of repairing torn MMPR is maintained, regardless of the degree of correction during OWHTO. CLINICAL RELEVANCE Both OWHTO and MMPR repair are known to protect the medial compartment of the knee. However, there are concerns in performing 2 procedures simultaneously. Results of our study showed that concurrent repair of the MMPR during OWHTO is useful for protecting the medial compartment of the knee with respect to tibiofemoral contact biomechanics.
Collapse
Affiliation(s)
- Hyung Jun Park
- Department of Orthopedic Surgery, Korea University College of Medicine, Ansan Hospital
| | - Moon Jong Chang
- Department of Orthopedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, Republic of Korea
| | - Ho-Jung Cho
- Department of Anatomy, Catholic Institute for Applied Anatomy, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Eunah Hong
- Department of Biomedicine & Health Science, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Tae Woo Kim
- Department of Orthopedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, Republic of Korea
| | - Chong Bum Chang
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Tae Soo Bae
- Department of Biomedical Engineering (BME), Jungwon University, Chungcheongbuk-do, Republic of Korea
| | - Dai-Soon Kwak
- Department of Anatomy, Catholic Institute for Applied Anatomy, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
| | - Seung-Baik Kang
- Department of Orthopedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, Republic of Korea.
| |
Collapse
|
36
|
Holder J, van Drongelen S, Uhlrich SD, Herrmann E, Meurer A, Stief F. Peak knee joint moments accurately predict medial and lateral knee contact forces in patients with valgus malalignment. Sci Rep 2023; 13:2870. [PMID: 36806297 PMCID: PMC9938879 DOI: 10.1038/s41598-023-30058-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Accepted: 02/15/2023] [Indexed: 02/19/2023] Open
Abstract
Compressive knee joint contact force during walking is thought to be related to initiation and progression of knee osteoarthritis. However, joint loading is often evaluated with surrogate measures, like the external knee adduction moment, due to the complexity of computing joint contact forces. Statistical models have shown promising correlations between medial knee joint contact forces and knee adduction moments in particularly in individuals with knee osteoarthritis or after total knee replacements (R2 = 0.44-0.60). The purpose of this study was to evaluate how accurately model-based predictions of peak medial and lateral knee joint contact forces during walking could be estimated by linear mixed-effects models including joint moments for children and adolescents with and without valgus malalignment. Peak knee joint moments were strongly correlated (R2 > 0.85, p < 0.001) with both peak medial and lateral knee joint contact forces. The knee flexion and adduction moments were significant covariates in the models, strengthening the understanding of the statistical relationship between both moments and medial and lateral knee joint contact forces. In the future, these models could be used to evaluate peak knee joint contact forces from musculoskeletal simulations using peak joint moments from motion capture software, obviating the need for time-consuming musculoskeletal simulations.
Collapse
Affiliation(s)
- Jana Holder
- Movement Analysis Laboratory, Department of Orthopedics (Friedrichsheim), University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt/Main, Germany. .,Department of Sport and Exercise Science, University of Salzburg, Salzburg, Austria.
| | - Stefan van Drongelen
- Dr. Rolf M. Schwiete Research Unit for Osteoarthritis, Department of Orthopedics (Friedrichsheim), University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt/Main, Germany
| | - Scott David Uhlrich
- grid.168010.e0000000419368956Department of Bioengineering, Stanford University, Stanford, CA USA ,grid.280747.e0000 0004 0419 2556Musculoskeletal Research Lab, VA Palo Alto Healthcare System, Palo Alto, CA USA
| | - Eva Herrmann
- grid.7839.50000 0004 1936 9721Institute of Biostatistics and Mathematical Modeling, Goethe University Frankfurt, Frankfurt/Main, Germany
| | - Andrea Meurer
- Department of Orthopedics (Friedrichsheim), University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt/Main, Germany ,Present Address: Medical Park St. Hubertus Klinik, Bad Wiessee, Germany
| | - Felix Stief
- Movement Analysis Laboratory, Department of Orthopedics (Friedrichsheim), University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt/Main, Germany ,Dr. Rolf M. Schwiete Research Unit for Osteoarthritis, Department of Orthopedics (Friedrichsheim), University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt/Main, Germany
| |
Collapse
|
37
|
Yan B, Huang X, Xu Y, Zou C. A Novel Locking Buttress Plate Designed for Simultaneous Medial and Posterolateral Tibial Plateau Fractures: Concept and Comparative Finite Element Analysis. Orthop Surg 2023; 15:1104-1116. [PMID: 36793219 PMCID: PMC10102290 DOI: 10.1111/os.13660] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 12/16/2022] [Accepted: 12/23/2022] [Indexed: 02/17/2023] Open
Abstract
OBJECTIVE The complex tibial plateau fractures involving both medial and posterolateral columns are of frequent occurrence in clinics, but the existing fixation system cannot deal with medial and posterolateral fragments simultaneously. Therefore, a novel locking buttress plate named as medial and posterior column plate (MPCP) was designed in this study to fix the simultaneous medial and posterolateral tibial plateau fractures. Meanwhile, the comparative finite element analysis (FEA) was conducted to investigate the discrepancy between MPCP and traditional multiple plates (MP + PLP) in their biomechanical characteristics. METHODS Two 3D finite element models of simultaneous medial and posterolateral tibial plateau fracture fixed with MPCP and MP + PLP system, respectively, was constructed. To imitate the axial stress of knee joint in ordinary life, diverse axial forces with 100, 500, 1000, and 1500 N were applied in the two fixation models, and then the equivalent displacement and stress nephograms and values were obtained. RESULTS The similar trend of displacement and stress increasing with the loads was observed in the two fixation models. However, several heterogeneities of displacement and stress distribution were found in the two fixation models. The max displacement and von Mises stress values of plates, screws, and fragments in the MPCP fixation model were significantly smaller than that in the MP + PLP fixation model, except for the max-shear stress values. CONCLUSION As a single locking buttress plate, the MPCP system showed the excellent benefit on improving the stability of the simultaneous medial and posterolateral tibial plateau fractures, compared with the traditional double plate fixation system. However, the excessive shear stress around screw holes should be paid attention to prevent trabecular microfracture and screw loosening.
Collapse
Affiliation(s)
- Bangji Yan
- Department of Orthopaedics and Traumatology, Cixi Hospital of Traditional Chinese Medicine, Ningbo, China
| | - Xiaotao Huang
- Department of Orthopaedics and Traumatology, Cixi Hospital of Traditional Chinese Medicine, Ningbo, China
| | - Yingxing Xu
- Department of Trauma Center, First Affiliated Hospital of Kunming Medical University, Kunming, China
| | - Chengshi Zou
- Department of Radiology, Cixi Hospital of Traditional Chinese Medicine, Ningbo, China
| |
Collapse
|
38
|
Cvečka J, Vajda M, Novotná A, Löfler S, Hamar D, Krčmár M. Benefits of Eccentric Training with Emphasis on Demands of Daily Living Activities and Feasibility in Older Adults: A Literature Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:3172. [PMID: 36833867 PMCID: PMC9958977 DOI: 10.3390/ijerph20043172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 01/26/2023] [Accepted: 02/09/2023] [Indexed: 06/18/2023]
Abstract
Aging is associated with a decline in physical capabilities and several other health-related conditions. One of the most common age-related processes is sarcopenia. Sarcopenia is usually accompanied with a decline in skeletal muscle mass and physical functioning. A decrease in these markers usually impacts basic daily living activities (DLAs), which become somewhat harder to accomplish for older individuals. Several research studies have examined the demands of DLA in older individuals with results indicating that activities such as walking, sitting, standing, stair climbing, stair descending, and running generate high demands on older adults. The forces that act on individuals are in most cases equal or multiple times higher relative to their body mass. For instance, it was reported that the GRF (ground reaction force) during stair descent ranged from 1.43 to 1.50 of BW (body weight) in an older population. Even higher demands were recorded during other related activities. These demands of DLA raise the question of appropriate rehabilitative or training management procedures. During the past decades, an eccentric form of resistance training gained popularity due to its effectiveness and lower metabolic demands, which seems to be an appropriate method to develop and maintain a basic level of strength capabilities in higher age. Multiple factors of eccentric training have been examined including modality of exercise, intensity, frequency, and safety of the elderly. Several modalities of eccentric exercise have been shown to be effective including traditional methods, as well as machine-based ones, with or without using some equipment. The studies included in this review varied in intensity from low to high; however, the most frequently used intensity was ≥50% of the maximal eccentric strength during two or three eccentric sessions per week. Importantly, the prevalence of injury of older adults appears to have been low to none, highlighting the safety of this approach. In summary, eccentric training prescriptions for older adults should consider the demands of DLA and the characteristics of the elderly for appropriate management of training recommendations.
Collapse
Affiliation(s)
- Ján Cvečka
- Hamar Institute for Human Performance, Faculty of Physical Education and Sports, Comenius University in Bratislava, 814 69 Bratislava, Slovakia
| | - Matej Vajda
- Hamar Institute for Human Performance, Faculty of Physical Education and Sports, Comenius University in Bratislava, 814 69 Bratislava, Slovakia
| | - Alexandra Novotná
- Hamar Institute for Human Performance, Faculty of Physical Education and Sports, Comenius University in Bratislava, 814 69 Bratislava, Slovakia
| | - Stefan Löfler
- Ludwig Boltzmann Institute for Rehabilitation Research, 1100 Vienna, Austria
| | - Dušan Hamar
- Hamar Institute for Human Performance, Faculty of Physical Education and Sports, Comenius University in Bratislava, 814 69 Bratislava, Slovakia
| | - Matúš Krčmár
- Department of Physical Education and Sports, Faculty of Education, Constantine the Philosopher University in Nitra, 949 74 Nitra, Slovakia
| |
Collapse
|
39
|
Thorsen T, Wen C, Porter J, Reinbolt J, Weinhandl JT, Zhang S. Tibiofemoral compressive force during downhill walking in patients with primary total knee arthroplasty: A statistical parametric mapping approach. Clin Biomech (Bristol, Avon) 2023; 102:105900. [PMID: 36739666 DOI: 10.1016/j.clinbiomech.2023.105900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Revised: 01/09/2023] [Accepted: 01/26/2023] [Indexed: 02/07/2023]
Abstract
BACKGROUND Downhill walking is a necessary part of daily life and an effective activity in post-operative rehabilitation following total knee arthroplasty. The purpose of this study was to determine differences in the behavior of total, medial, and lateral tibiofemoral compressive forces as well as knee extensor and flexor muscle forces between different limbs of patients with total knee arthroplasty (replaced, non-replaced) during downhill and level walking. METHODS Musculoskeletal modeling and simulation were implemented to determine muscle forces and tibiofemoral compressive forces in 25 patients with total knee arthroplasty. A 2 × 2 [Limb (replaced, non-replaced) × Slope (0°, 10°)] Statistical parametric mapping repeated measures analysis of variance was conducted on selected variables. FINDINGS Statistical parametric mapping did not identify any between-limb differences for compressive or muscle forces. Differences in joint compressive and muscle forces persisted throughout different intervals of stance-phase between level and downhill walking. Knee extensor muscle forces were distinctly greater during level walking for nearly all of stance phase. Knee flexor muscle force was greater during downhill walking for >60% of stance. Statistical parametric mapping did identify regions of significance between level and downhill walking that coincided temporally (near loading response and push off) with peak joint moment and joint compressive forces traditionally reported using discrete variable analyses. INTERPRETATION Downhill walking may be a safe and useful rehabilitation tool for post-knee arthroplasty rehabilitation that will not disproportionally load either the replaced or the non-replaced joint and where the quadriceps muscles can be strengthened during a gait-specific task.
Collapse
Affiliation(s)
- Tanner Thorsen
- School of Kinesiology and Nutrition, The University of Southern Mississippi, Hattiesburg, MS, USA
| | - Chen Wen
- Department of Kinesiology, Recreation and Sport Studies, The University of Tennessee, Knoxville, TN, USA
| | - Jared Porter
- Department of Kinesiology, Recreation and Sport Studies, The University of Tennessee, Knoxville, TN, USA
| | - Jeffery Reinbolt
- Department of Mechanical, Aerospace, and Biomedical Engineering, The University of Tennessee, Knoxville, TN, USA
| | - Joshua T Weinhandl
- Department of Kinesiology, Recreation and Sport Studies, The University of Tennessee, Knoxville, TN, USA
| | - Songning Zhang
- Department of Kinesiology, Recreation and Sport Studies, The University of Tennessee, Knoxville, TN, USA.
| |
Collapse
|
40
|
Schonhoff M, Beckmann NA, Schwarze M, Eissler M, Kretzer JP, Renkawitz T, Jaeger S. Is TKA femoral implant stability improved by pressure applied cement? a comparison of 2 cementing techniques. BMC Musculoskelet Disord 2023; 24:51. [PMID: 36670400 PMCID: PMC9863212 DOI: 10.1186/s12891-023-06151-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Accepted: 01/09/2023] [Indexed: 01/22/2023] Open
Abstract
BACKGROUND The majority of knee endoprostheses are cemented. In an earlier study the effects of different cementing techniques on cement penetration were evaluated using a Sawbone model. In this study we used a human cadaver model to study the effect of different cementing techniques on relative motion between the implant and the femoral shaft component under dynamic loading. METHODS Two different cementing techniques were tested in a group of 15 pairs of human fresh frozen legs. In one group a conventional cementation technique was used and, in another group, cementation was done using a pressurizing technique. Under dynamic loading that simulated real life conditions relative motion at the bone-implant interface were studied at 20 degrees and 50 degrees flexion. RESULTS In both scenarios, the relative motion anterior was significantly increased by pressure application. Distally, it was the same with higher loads. No significant difference could be measured posteriorly at 20°. At 50° flexion, however, pressurization reduced the posterior relative motion significantly at each load level. CONCLUSION The use of the pressurizer does not improve the overall fixation compared to an adequate manual cement application. The change depends on the loading, flexion angle and varies in its proportion in between the interface zones.
Collapse
Affiliation(s)
- Mareike Schonhoff
- grid.5253.10000 0001 0328 4908Laboratory of Biomechanics and Implant Research, Department of Orthopaedics, Heidelberg University Hospital, 69118 Heidelberg, Germany
| | - Nicholas A. Beckmann
- grid.5253.10000 0001 0328 4908Department of Orthopaedics, Heidelberg University Hospital, 69118 Heidelberg, Germany
| | - Martin Schwarze
- grid.5253.10000 0001 0328 4908Laboratory of Biomechanics and Implant Research, Department of Orthopaedics, Heidelberg University Hospital, 69118 Heidelberg, Germany
| | - Marvin Eissler
- grid.5253.10000 0001 0328 4908Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany
| | - J. Philippe Kretzer
- grid.5253.10000 0001 0328 4908Laboratory of Biomechanics and Implant Research, Department of Orthopaedics, Heidelberg University Hospital, 69118 Heidelberg, Germany
| | - Tobias Renkawitz
- grid.5253.10000 0001 0328 4908Department of Orthopaedics, Heidelberg University Hospital, 69118 Heidelberg, Germany
| | - Sebastian Jaeger
- grid.5253.10000 0001 0328 4908Laboratory of Biomechanics and Implant Research, Department of Orthopaedics, Heidelberg University Hospital, 69118 Heidelberg, Germany
| |
Collapse
|
41
|
Additively manufactured controlled porous orthopedic joint replacement designs to reduce bone stress shielding: a systematic review. J Orthop Surg Res 2023; 18:42. [PMID: 36647070 PMCID: PMC9841707 DOI: 10.1186/s13018-022-03492-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 12/30/2022] [Indexed: 01/18/2023] Open
Abstract
BACKGROUND Total joint replacements are an established treatment for patients suffering from reduced mobility and pain due to severe joint damage. Aseptic loosening due to stress shielding is currently one of the main reasons for revision surgery. As this phenomenon is related to a mismatch in mechanical properties between implant and bone, stiffness reduction of implants has been of major interest in new implant designs. Facilitated by modern additive manufacturing technologies, the introduction of porosity into implant materials has been shown to enable significant stiffness reduction; however, whether these devices mitigate stress-shielding associated complications or device failure remains poorly understood. METHODS In this systematic review, a broad literature search was conducted in six databases (Scopus, Web of Science, Medline, Embase, Compendex, and Inspec) aiming to identify current design approaches to target stress shielding through controlled porous structures. The search keywords included 'lattice,' 'implant,' 'additive manufacturing,' and 'stress shielding.' RESULTS After the screening of 2530 articles, a total of 46 studies were included in this review. Studies focusing on hip, knee, and shoulder replacements were found. Three porous design strategies were identified, specifically uniform, graded, and optimized designs. The latter included personalized design approaches targeting stress shielding based on patient-specific data. All studies reported a reduction of stress shielding achieved by the presented design. CONCLUSION Not all studies used quantitative measures to describe the improvements, and the main stress shielding measures chosen varied between studies. However, due to the nature of the optimization approaches, optimized designs were found to be the most promising. Besides the stiffness reduction, other factors such as mechanical strength can be considered in the design on a patient-specific level. While it was found that controlled porous designs are overall promising to reduce stress shielding, further research and clinical evidence are needed to determine the most superior design approach for total joint replacement implants.
Collapse
|
42
|
Winkler T, Bell L, Bender A, Trepczynski A, Duda GN, Baur AJD, Damm P. Periarticular muscle status affects in vivo tibio-femoral joint loads after total knee arthroplasty. Front Bioeng Biotechnol 2023; 11:1075357. [PMID: 37034264 PMCID: PMC10073542 DOI: 10.3389/fbioe.2023.1075357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 03/09/2023] [Indexed: 04/11/2023] Open
Abstract
Background: Total knee arthroplasty (TKA) is a highly effective treatment for severe knee osteoarthritis that is increasingly performed in younger, more active patients. As postoperative muscular impairments may negatively affect surgical outcomes and implant longevity, functional muscle recovery gains increasing importance in meeting future patient demands. This study aimed to assess the status of periarticular muscles in the long-term follow-up after TKA and to evaluate its impact on in vivo tibio-femoral joint loads. Methods: A case series was created, with eight patients with knee osteoarthritis. All subjects received an instrumented knee implant in unilateral TKA. Native computed tomography scans, acquired pre and postoperatively, were used to evaluate distal muscle volumes and fatty infiltration. In vivo tibio-femoral joint loads were measured telemetrically during standing, walking, stair climbing and chair rising and were correlated to muscle status. Results: Postoperatively a reduction in fatty infiltration across all periarticular muscles was pronounced. High average peak loads acted in the tibio-femoral joint ranging from 264% during stand-to-sit activities up to 341% body weight (BW) during stair descent. Fatty infiltration of the m. quadriceps femoris and hamstrings were associated with increased tibio-femoral joint contact forces during walking (r = 0.542; 0.412 and 0.766). Conclusion: The findings suggest that a fatty infiltration of periarticular muscles may lead to increased tibio-femoral joint contact forces. However, we only observed weak correlations between these parameters. Improvements in functional mobility and the restoration of a pain-free joint likely explain the observed postoperative reductions in fatty infiltration. Perioperative rehabilitation approaches targeting residual impairments in muscle quality could, contribute to reduced tibio-femoral joint loads and improved long-term outcomes of TKA. However, it has to be pointed out that the study included a small number of patients, which may limit its validity.
Collapse
Affiliation(s)
- Tobias Winkler
- Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Center for Musculoskeletal Biomechanics and Regeneration (Julius Wolff Institute), Berlin, Germany
- Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Berlin Institute of Health Institute for Regenerative Therapies, Berlin, Germany
- Center for Musculoskeletal Surgery, Charité—Universitätsmedizin Berlin, Berlin, Germany
| | - Louisa Bell
- Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Center for Musculoskeletal Biomechanics and Regeneration (Julius Wolff Institute), Berlin, Germany
| | - Alwina Bender
- Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Center for Musculoskeletal Biomechanics and Regeneration (Julius Wolff Institute), Berlin, Germany
| | - Adam Trepczynski
- Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Center for Musculoskeletal Biomechanics and Regeneration (Julius Wolff Institute), Berlin, Germany
| | - Georg N. Duda
- Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Center for Musculoskeletal Biomechanics and Regeneration (Julius Wolff Institute), Berlin, Germany
| | | | - Philipp Damm
- Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Center for Musculoskeletal Biomechanics and Regeneration (Julius Wolff Institute), Berlin, Germany
- *Correspondence: Philipp Damm,
| |
Collapse
|
43
|
Maslaris A, Tsiridis E, Schoeneberg C, Pass B, Spyrou G, Maris A, Matziolis G. Does stem profile have an impact on the failure patterns in revision total knee arthroplasty? Arch Orthop Trauma Surg 2023; 143:1549-1569. [PMID: 36450936 PMCID: PMC9957861 DOI: 10.1007/s00402-022-04683-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Accepted: 10/23/2022] [Indexed: 12/02/2022]
Abstract
INTRODUCTION Revision total knee arthroplasty (RTKA) has been increasing continuously. The results of RTKA still remain unsatisfactory. Failure patterns and risk factors in RTKA were thoroughly analyzed, with periprosthetic joint infections (PJI) and aseptic loosening remaining at the forefront of re-revision (ReRTKA) causes. While there is evidence that stem profile impacts the revisability of cemented implants, its association with the modes of RTKA failure is unknown. METHODS 50 consecutive ReRTKA performed in a single orthopedic center during 2016-2017 were retrospectively analyzed. The cases were stratified according to age, sex, number of preexisting revisions, fixation technique, stem design and causes of re-revision. All explanted implants with conical vs. cylindrical stem profiles were compared. RESULTS Mean age was 67 ± 11.5, and 54% were females. 72% of the cases had ≥ 3 previous revisions. 88% were full-cemented, 3% hybrid and 9% press-fit stems. 36% of the RTKA had conical, 58% cylindrical and 6% combined stem profiles. 92% of the RTKA components were removed. Removal causes were: PJI (52.2%), aseptic loosening (34.8%), implant malposition (9.8%), painful knee (1.1%) and instability (2.2%). While the overall RTKA failure patterns were equally distributed between conical and cylindrical stems, subgroup analysis of only cemented ReRTKA revealed a higher incidence of aseptic loosening within cylindrical stem profiles (46.7% vs. 25.7%, P = 0.05). CONCLUSION Stem profile may have an impact on the process of aseptic loosening in cemented non-metaphyseal engaging RTKA, with cylindrical designs tending to worse outcomes than conical designs. Large cohort studies could provide more clarity on current observation.
Collapse
Affiliation(s)
- Alexander Maslaris
- Department of Orthopedics, Waldkliniken Eisenberg, Jena University Hospital, Klosterlausnitzer Str. 81, 07607, Eisenberg, Germany. .,Department of Orthopedics and Trauma Surgery, Alfried-Krupp Hospital Essen, Alfried-Krupp-Straße 21, 45131, Essen, Germany.
| | - Eleftherios Tsiridis
- grid.4793.90000000109457005Academic Orthopedic Department, Papageorgiou General Hospital, Aristotle University Medical School, Thessaloniki, GRC Greece
| | - Carsten Schoeneberg
- grid.476313.4Department of Orthopedics and Trauma Surgery, Alfried-Krupp Hospital Essen, Alfried-Krupp-Straße 21, 45131 Essen, Germany
| | - Bastian Pass
- grid.476313.4Department of Orthopedics and Trauma Surgery, Alfried-Krupp Hospital Essen, Alfried-Krupp-Straße 21, 45131 Essen, Germany
| | - Georgios Spyrou
- grid.476313.4Department of Orthopedics and Trauma Surgery, Alfried-Krupp Hospital Essen, Alfried-Krupp-Straße 21, 45131 Essen, Germany
| | - Alexandros Maris
- grid.420468.cDepartment of Orthopedics, Great Ormond Street Hospital NHS Foundation Trust, Great Ormond Street, London, WC1N 3JH UK
| | - Georg Matziolis
- grid.275559.90000 0000 8517 6224Department of Orthopedics, Waldkliniken Eisenberg, Jena University Hospital, Klosterlausnitzer Str. 81, 07607 Eisenberg, Germany
| |
Collapse
|
44
|
Zheng Z, Liu Y, Zhang A, Chen H, Wan Q, Zhong L, Wang X, Han Q, Wang J. Medial-lateral translational malalignment of the prosthesis on tibial stress distribution in total knee arthroplasty: A finite element analysis. Front Bioeng Biotechnol 2023; 11:1119204. [PMID: 36937745 PMCID: PMC10017773 DOI: 10.3389/fbioe.2023.1119204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Accepted: 02/20/2023] [Indexed: 03/06/2023] Open
Abstract
Background: Poor prosthesis alignment during total knee arthroplasty could cause problems such as polyethylene spacer wear, leading to surgical failure and revision surgery. The problems caused by the malalignment of the tibial plateau prosthesis in the medial and lateral planes are unclear. We aimed to investigate the stress distribution and micromotion of the tibia when the tibial plateau prosthesis is translated 1 and 2 mm medially and laterally, respectively, using finite element analysis (FEA). Method: A non-homogeneous tibia model was created and load conditions when standing on two legs were applied using FEA to simulate the misaligned prosthesis. The stresses, stress distribution, and micromotion of the proximal tibia were analyzed in five positions of the tibial plateau prosthesis: Lateral-2 mm; Lateral-1 mm; Medium; Medial-2 mm; Medial-1 mm. Result: The maximum stress in the five groups with different misalignments of the platform was 47.29 MPa (Lateral-2 mm). The maximum micromotion among the five groups in different positions was 7.215 μm (Lateral-2 mm). Conclusion: When placing the tibial plateau prosthesis during total knee arthroplasty, an error of 2 mm or less is acceptable as long as it does not overhang.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Qing Han
- *Correspondence: Qing Han, ; Jincheng Wang,
| | | |
Collapse
|
45
|
Lampen N, Su H, Chan DD, Yan P. Finite element modeling with subject-specific mechanical properties to assess knee osteoarthritis initiation and progression. J Orthop Res 2023; 41:72-83. [PMID: 35438803 DOI: 10.1002/jor.25338] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2021] [Revised: 03/14/2022] [Accepted: 03/31/2022] [Indexed: 02/04/2023]
Abstract
Finite element models of the knee can be used to identify regions at risk of mechanical failure in studies of osteoarthritis. Models of the knee often implement joint geometry obtained from magnetic resonance imaging (MRI) or gait kinematics from motion capture to increase model specificity for a given subject. However, differences exist in cartilage material properties regionally as well as between subjects. This paper presents a method to create subject-specific finite element models of the knee that assigns cartilage material properties from T2 relaxometry. We compared our T2 -refined model to identical models with homogeneous material properties. When tested on three subjects from the Osteoarthritis Initiative data set, we found the T2 -refined models estimated higher principal stresses and shear strains in most cartilage regions and corresponded better to increases in KL grade in follow-ups compared to their corresponding homogeneous material models. Measures of cumulative stress within regions of a T2 -refined model also correlated better with the region's cartilage morphology MRI Osteoarthritis Knee Score as compared with the homogeneous model. We conclude that spatially heterogeneous T2 -refined material properties improve the subject-specificity of finite element models compared to homogeneous material properties in osteoarthritis progression studies. Statement of Clinical Significance: T2 -refined material properties can improve subject-specific finite element model assessments of cartilage degeneration.
Collapse
Affiliation(s)
- Nathan Lampen
- Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, New York, USA
| | - Haoyun Su
- Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, New York, USA
| | - Deva D Chan
- Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, New York, USA.,Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA
| | - Pingkun Yan
- Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, New York, USA
| |
Collapse
|
46
|
Petitjean N, Canadas P, Royer P, Noël D, Le Floc'h S. Cartilage biomechanics: From the basic facts to the challenges of tissue engineering. J Biomed Mater Res A 2022; 111:1067-1089. [PMID: 36583681 DOI: 10.1002/jbm.a.37478] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 11/07/2022] [Accepted: 11/22/2022] [Indexed: 12/31/2022]
Abstract
Articular cartilage (AC) is the thin tissue that covers the long bone ends in the joints and that ensures the transmission of forces between adjacent bones while allowing nearly frictionless movements between them. AC repair is a technologic and scientific challenge that has been addressed with numerous approaches. A major deadlock is the capacity to take in account its complex mechanical properties in repair strategies. In this review, we first describe the major mechanical behaviors of AC for the non-specialists. Then, we show how researchers have progressively identified specific mechanical parameters using mathematical models. There are still gaps in our understanding of some of the observations concerning AC biomechanical properties, particularly the differences in extracellular matrix stiffness measured at the microscale and at the millimetric scale. Nevertheless, for bioengineering applications, AC repair strategies must take into account what are commonly considered the main mechanical features of cartilage: its ability to withstand high stresses through three main behaviors (elasticity, poroelasticity and swelling). Finally, we emphasize that future studies need to investigate AC mechanical properties at different scales, particularly the gradient of mechanical properties around cells and across the cartilage depth, and the differences in mechanical properties at different scales. This multi-scale approach could greatly enhance the success of AC restorative approaches.
Collapse
Affiliation(s)
| | | | - Pascale Royer
- LMGC, University of Montpellier, CNRS, Montpellier, France
| | - Danièle Noël
- IRMB, University of Montpellier, INSERM, Montpellier, France.,Clinical Immunology and Osteoarticular Disease Therapeutic Unit, Department of Rheumatology, CHU Montpellier, France
| | | |
Collapse
|
47
|
Wang H, Fang C, Tao M, Shi Q, He K, Cheng CK. Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis. Front Bioeng Biotechnol 2022; 10:967411. [PMID: 36601393 PMCID: PMC9807226 DOI: 10.3389/fbioe.2022.967411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Accepted: 12/06/2022] [Indexed: 12/23/2022] Open
Abstract
Background: Anterior cruciate ligament reconstruction (ACLR) using a generally columnar graft is considered the gold standard for treating anterior cruciate ligament ruptures, but such grafts cannot replicate the geometry and mechanical properties of the native anterior cruciate ligament. Purpose: To evaluate the effectiveness of an innovative hourglass-shaped graft versus a traditional columnar graft for restoring joint stability and graft force, while avoiding notch impingement following anterior cruciate ligament reconstruction. Methods: Finite element models of a human knee were developed to simulate ① An intact state, ② anterior cruciate ligament reconstruction using columnar grafts with different diameters (7.5-12 mm in 0.5 mm increments), ③ anterior cruciate ligament reconstruction using columnar grafts with different Young's moduli (129.4, 168.0 and 362.2 MPa) and ④ anterior cruciate ligament reconstruction using hourglass-shaped grafts with different Young's moduli. The knee model was flexed to 30° and loaded with an anterior tibial load of 103 N, internal tibial moment of 7.5 Nm, and valgus tibial moment of 6.9 Nm. The risk of notch impingement, knee stability and graft forces were compared among the different groups. Results: This study found that columnar grafts could not simultaneously restore knee stability in different degree of freedoms (DOFs) and graft force to a level similar to that of the intact knee. The anterior tibial translation and graft force were restored to a near-normal condition when the internal tibial rotation was over-restrained and valgus tibial rotation was lax. A graft diameter of at least 10 mm was needed to restore knee stability and graft force to physiological levels, but such large grafts were found to be at high risk of notch impingement. In contrast, the hourglass-shaped graft was able to simultaneously restore both knee stability and graft force at knee flexion of 30° while also having a much lower risk of impingement. Conclusion: Under knee flexion angle of 30°, an hourglass-shaped graft was better able to restore joint stability and graft force to a near-physiological level than columnar grafts, while also reducing the risk of notch impingement.
Collapse
Affiliation(s)
- Huizhi Wang
- Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Chaohua Fang
- Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.,Department of Joint Surgery, The 6th Hospital of Ningbo, Ningbo, Zhejiang, China
| | - Mingzhu Tao
- Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Qinyi Shi
- Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Kaixin He
- Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Cheng-Kung Cheng
- Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.,*Correspondence: Cheng-Kung Cheng,
| |
Collapse
|
48
|
Kayll SA, Hinman RS, Bennell KL, Bryant AL, Rowe PL, Paterson KL. The effect of biomechanical foot-based interventions on patellofemoral joint loads during gait in adults with and without patellofemoral pain or osteoarthritis: a systematic review protocol. J Foot Ankle Res 2022; 15:91. [PMID: 36514101 PMCID: PMC9746129 DOI: 10.1186/s13047-022-00596-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Accepted: 12/02/2022] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Patellofemoral pain is highly prevalent across the lifespan, and a significant proportion of people report unfavourable outcomes years after diagnosis. Previous research has implicated patellofemoral joint loading during gait in patellofemoral pain and its sequelae, patellofemoral osteoarthritis. Biomechanical foot-based interventions (e.g., footwear, insoles, orthotics, taping or bracing) can alter patellofemoral joint loads by reducing motions at the foot that increase compression between the patella and underlying femur via coupling mechanisms, making them a promising treatment option. This systematic review will summarise the evidence about the effect of biomechanical foot-based interventions on patellofemoral joint loads during gait in adults with and without patellofemoral pain and osteoarthritis. METHODS MEDLINE (Ovid), the Cumulative Index to Nursing and Allied Health Literature CINAHL, The Cochrane Central Register of Controlled Trials (CENTRAL), SPORTdiscus (EBSCO) and Embase (Ovid) will be searched. Our search strategy will include terms related to 'patellofemoral joint', 'loads' and 'biomechanical foot-based interventions'. We will include studies published in the English language that assess the effect of biomechanical foot-based interventions on patellofemoral joint loads, quantified by patellofemoral joint pressure, patellofemoral joint reaction force and/or knee flexion moment. Two reviewers will independently screen titles and abstracts, complete full-text reviews, and extract data from included studies. Two reviewers will assess study quality using the Revised Cochrane Risk of Bias (RoB 2) tool or the Cochrane Risk Of Bias In Non-Randomized Studies - of Interventions (ROBINS-I) tool. We will provide a synthesis of the included studies' characteristics and results. If three or more studies are sufficiently similar in population and intervention, we will pool the data to conduct a meta-analysis and report findings as standardised mean differences with 95% confidence intervals. If a meta-analysis cannot be performed, we will conduct a narrative synthesis of the results and produce forest plots for individual studies. DISCUSSION This protocol outlines the methods of a systematic review that will determine the effect of biomechanical foot-based interventions on patellofemoral joint loads. Our findings will inform clinical practice by identifying biomechanical foot-based interventions that reduce or increase patellofemoral joint loads, which may aid the treatment of adults with patellofemoral pain and osteoarthritis. TRIAL REGISTRATION Registered with PROSPERO on the 4th of May 2022 (CRD42022315207).
Collapse
Affiliation(s)
- Samual A. Kayll
- grid.1008.90000 0001 2179 088XCentre for Health, Exercise and Sports Medicine, Department of Physiotherapy, School of Health Sciences, The University of Melbourne, 3010, Level 7, Alan Gilbert Building, 161 Barry Street, Parkville, Australia
| | - Rana S. Hinman
- grid.1008.90000 0001 2179 088XCentre for Health, Exercise and Sports Medicine, Department of Physiotherapy, School of Health Sciences, The University of Melbourne, 3010, Level 7, Alan Gilbert Building, 161 Barry Street, Parkville, Australia
| | - Kim L. Bennell
- grid.1008.90000 0001 2179 088XCentre for Health, Exercise and Sports Medicine, Department of Physiotherapy, School of Health Sciences, The University of Melbourne, 3010, Level 7, Alan Gilbert Building, 161 Barry Street, Parkville, Australia
| | - Adam L. Bryant
- grid.1008.90000 0001 2179 088XCentre for Health, Exercise and Sports Medicine, Department of Physiotherapy, School of Health Sciences, The University of Melbourne, 3010, Level 7, Alan Gilbert Building, 161 Barry Street, Parkville, Australia
| | - Patrick L. Rowe
- grid.1008.90000 0001 2179 088XCentre for Health, Exercise and Sports Medicine, Department of Physiotherapy, School of Health Sciences, The University of Melbourne, 3010, Level 7, Alan Gilbert Building, 161 Barry Street, Parkville, Australia
| | - Kade L. Paterson
- grid.1008.90000 0001 2179 088XCentre for Health, Exercise and Sports Medicine, Department of Physiotherapy, School of Health Sciences, The University of Melbourne, 3010, Level 7, Alan Gilbert Building, 161 Barry Street, Parkville, Australia
| |
Collapse
|
49
|
Waiteman MC, Chia L, Ducatti MHM, Bazett-Jones DM, Pappas E, de Azevedo FM, Briani RV. Trunk Biomechanics in Individuals with Knee Disorders: A Systematic Review with Evidence Gap Map and Meta-analysis. SPORTS MEDICINE - OPEN 2022; 8:145. [PMID: 36503991 PMCID: PMC9742076 DOI: 10.1186/s40798-022-00536-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 11/15/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND The trunk is the foundation for transfer and dissipation of forces throughout the lower extremity kinetic chain. Individuals with knee disorders may employ trunk biomechanical adaptations to accommodate forces at the knee or compensate for muscle weakness. This systematic review aimed to synthesize the literature comparing trunk biomechanics between individuals with knee disorders and injury-free controls. METHODS Five databases were searched from inception to January 2022. Observational studies comparing trunk kinematics or kinetics during weight-bearing tasks (e.g., stair negotiation, walking, running, landings) between individuals with knee disorders and controls were included. Meta-analyses for each knee disorder were performed. Outcome-level certainty was assessed using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE), and evidence gap maps were created. RESULTS A total of 81 studies investigating trunk biomechanics across six different knee disorders were included (i.e., knee osteoarthritis [OA], total knee arthroplasty [TKA], patellofemoral pain [PFP], patellar tendinopathy [PT], anterior cruciate ligament deficiency [ACLD], and anterior cruciate ligament reconstruction [ACLR]). Individuals with knee OA presented greater trunk flexion during squatting (SMD 0.88, 95% CI 0.58-1.18) and stepping tasks (SMD 0.56, 95% CI 0.13-.99); ipsilateral and contralateral trunk lean during walking (SMD 1.36; 95% CI 0.60-2.11) and sit-to-stand (SMD 1.49; 95% CI 0.90-2.08), respectively. Greater trunk flexion during landing tasks in individuals with PFP (SMD 0.56; 95% CI 0.01-1.12) or ACLR (SMD 0.48; 95% CI 0.21-.75) and greater ipsilateral trunk lean during single-leg squat in individuals with PFP (SMD 1.01; 95% CI 0.33-1.70) were also identified. No alterations in trunk kinematics of individuals with TKA were identified. Evidence gap maps outlined the lack of investigations for individuals with PT or ACLD, as well as for trunk kinetics across knee disorders. CONCLUSION Individuals with knee OA, PFP, or ACLR present with altered trunk kinematics in the sagittal and frontal planes. The findings of this review support the assessment of trunk biomechanics in these individuals in order to identify possible targets for rehabilitation and avoidance strategies. TRIAL REGISTRATION PROSPERO registration number: CRD42019129257.
Collapse
Affiliation(s)
- Marina C. Waiteman
- grid.410543.70000 0001 2188 478XDepartment of Physical Therapy, School of Science and Technology, Sao Paulo State University (UNESP), 305, Roberto Simonsen Street, Presidente Prudente, Sao Paulo 19060-900 Brazil
| | - Lionel Chia
- grid.1013.30000 0004 1936 834XSydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW Australia ,Cleveland Guardians Baseball Company, Cleveland, OH USA
| | - Matheus H. M. Ducatti
- grid.410543.70000 0001 2188 478XDepartment of Physical Therapy, School of Science and Technology, Sao Paulo State University (UNESP), 305, Roberto Simonsen Street, Presidente Prudente, Sao Paulo 19060-900 Brazil
| | - David M. Bazett-Jones
- grid.267337.40000 0001 2184 944XSchool of Exercise and Rehabilitation Sciences, College of Health and Human Services, University of Toledo, Toledo, OH USA
| | - Evangelos Pappas
- grid.1007.60000 0004 0486 528XSchool of Medicine and Illawarra Health and Medical Research Institute, The University of Wollongong, Wollongong, NSW Australia
| | - Fábio M. de Azevedo
- grid.410543.70000 0001 2188 478XDepartment of Physical Therapy, School of Science and Technology, Sao Paulo State University (UNESP), 305, Roberto Simonsen Street, Presidente Prudente, Sao Paulo 19060-900 Brazil
| | - Ronaldo V. Briani
- grid.410543.70000 0001 2188 478XDepartment of Physical Therapy, School of Science and Technology, Sao Paulo State University (UNESP), 305, Roberto Simonsen Street, Presidente Prudente, Sao Paulo 19060-900 Brazil
| |
Collapse
|
50
|
Gibbons KD, Malbouby V, Alvarez O, Fitzpatrick CK. Robust automatic hexahedral cartilage meshing framework enables population-based computational studies of the knee. Front Bioeng Biotechnol 2022; 10:1059003. [PMID: 36568304 PMCID: PMC9780478 DOI: 10.3389/fbioe.2022.1059003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 11/25/2022] [Indexed: 12/13/2022] Open
Abstract
Osteoarthritis of the knee is increasingly prevalent as our population ages, representing an increasing financial burden, and severely impacting quality of life. The invasiveness of in vivo procedures and the high cost of cadaveric studies has left computational tools uniquely suited to study knee biomechanics. Developments in deep learning have great potential for efficiently generating large-scale datasets to enable researchers to perform population-sized investigations, but the time and effort associated with producing robust hexahedral meshes has been a limiting factor in expanding finite element studies to encompass a population. Here we developed a fully automated pipeline capable of taking magnetic resonance knee images and producing a working finite element simulation. We trained an encoder-decoder convolutional neural network to perform semantic image segmentation on the Imorphics dataset provided through the Osteoarthritis Initiative. The Imorphics dataset contained 176 image sequences with varying levels of cartilage degradation. Starting from an open-source swept-extrusion meshing algorithm, we further developed this algorithm until it could produce high quality meshes for every sequence and we applied a template-mapping procedure to automatically place soft-tissue attachment points. The meshing algorithm produced simulation-ready meshes for all 176 sequences, regardless of the use of provided (manually reconstructed) or predicted (automatically generated) segmentation labels. The average time to mesh all bones and cartilage tissues was less than 2 min per knee on an AMD Ryzen 5600X processor, using a parallel pool of three workers for bone meshing, followed by a pool of four workers meshing the four cartilage tissues. Of the 176 sequences with provided segmentation labels, 86% of the resulting meshes completed a simulated flexion-extension activity. We used a reserved testing dataset of 28 sequences unseen during network training to produce simulations derived from predicted labels. We compared tibiofemoral contact mechanics between manual and automated reconstructions for the 24 pairs of successful finite element simulations from this set, resulting in mean root-mean-squared differences under 20% of their respective min-max norms. In combination with further advancements in deep learning, this framework represents a feasible pipeline to produce population sized finite element studies of the natural knee from subject-specific models.
Collapse
|