1
|
Peng C, Huang G, Chen X, Xie Z, Ali S, Chen X, Nie H, Yang Z, Zhu L, Chen X, Yan S. Identification of near-infrared characteristic bands of small bowel necrosis based on cellwise detection algorithm. JOURNAL OF BIOPHOTONICS 2024; 17:e202300438. [PMID: 38468556 DOI: 10.1002/jbio.202300438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 01/10/2024] [Accepted: 01/30/2024] [Indexed: 03/13/2024]
Abstract
The near-infrared spectroscopy is often used to distinguish small bowel necrosis due to necrotizing enterocolitis (NEC). The characteristic bands of small bowel necrosis, as an important basis for evaluating the confidence of the differentiation results, are challenging to identify quickly. In this study, we proposed to identify characteristic bands of lesion samples based on hyperspectral imaging (HSI) and cellwise outlier detection. Rabbits were used as an animal model to simulate the clinical symptoms of NEC. The rabbits were detected at intervals of 10, 30, 60, and 90 min. The characteristic bands were identified within the same rabbit, between different rabbits and at different times. The result showed the bands near 763 nm, corresponding to the absorption peak of deoxyhemoglobin, were the characteristic bands separating samples with NEC. The identification result was plausible because hypoxia was the main cause of NEC. The method was easy to perform.
Collapse
Affiliation(s)
- Chenxi Peng
- College of Life and Environmental Sciences, Wenzhou University, Wenzhou, China
| | - Guangzao Huang
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China
| | - Xiaojing Chen
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China
| | - Zhonghao Xie
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China
| | - Shujat Ali
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China
| | - Xi Chen
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China
| | - Huagui Nie
- College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou, China
| | - Zhi Yang
- College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou, China
| | - Libin Zhu
- Pediatric General Surgery, The Second Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Xiaoqing Chen
- Pediatric General Surgery, The Second Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Shubin Yan
- School of Electrical Engineering, Zhejiang University of Water Resources and Electric Power, Hangzhou, China
| |
Collapse
|
2
|
Watanabe K, Koch Esteves N, Gibson OR, Akiyama K, Watanabe S, González-Alonso J. Heat-related changes in the velocity and kinetic energy of flowing blood influence the human heart's output during hyperthermia. J Physiol 2024; 602:2227-2251. [PMID: 38690610 DOI: 10.1113/jp285760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 04/03/2024] [Indexed: 05/02/2024] Open
Abstract
Passive whole-body hyperthermia increases limb blood flow and cardiac output (Q ̇ $\dot Q$ ), but the interplay between peripheral and central thermo-haemodynamic mechanisms remains unclear. Here we tested the hypothesis that local hyperthermia-induced alterations in peripheral blood flow and blood kinetic energy modulate flow to the heart andQ ̇ $\dot Q$ . Body temperatures, regional (leg, arm, head) and systemic haemodynamics, and left ventricular (LV) volumes and functions were assessed in eight healthy males during: (1) 3 h control (normothermic condition); (2) 3 h of single-leg heating; (3) 3 h of two-leg heating; and (4) 2.5 h of whole-body heating. Leg, forearm, and extracranial blood flow increased in close association with local rises in temperature while brain perfusion remained unchanged. Increases in blood velocity with small to no changes in the conduit artery diameter underpinned the augmented limb and extracranial perfusion. In all heating conditions,Q ̇ $\dot Q$ increased in association with proportional elevations in systemic vascular conductance, related to enhanced blood flow, blood velocity, vascular conductance and kinetic energy in the limbs and head (all R2 ≥ 0.803; P < 0.001), but not in the brain. LV systolic (end-systolic elastance and twist) and diastolic functional profiles (untwisting rate), pulmonary ventilation and systemic aerobic metabolism were only altered in whole-body heating. These findings substantiate the idea that local hyperthermia-induced selective alterations in peripheral blood flow modulate the magnitude of flow to the heart andQ ̇ $\dot Q$ through changes in blood velocity and kinetic energy. Localised heat-activated events in the peripheral circulation therefore affect the human heart's output. KEY POINTS: Local and whole-body hyperthermia increases limb and systemic perfusion, but the underlying peripheral and central heat-sensitive mechanisms are not fully established. Here we investigated the regional (leg, arm and head) and systemic haemodynamics (cardiac output:Q ̇ $\dot Q$ ) during passive single-leg, two-leg and whole-body hyperthermia to determine the contribution of peripheral and central thermosensitive factors in the control of human circulation. Single-leg, two-leg, and whole-body hyperthermia induced graded increases in leg blood flow andQ ̇ $\dot Q$ . Brain blood flow, however, remained unchanged in all conditions. Ventilation, extracranial blood flow and cardiac systolic and diastolic functions only increased during whole-body hyperthermia. The augmentedQ ̇ $\dot Q$ with hyperthermia was tightly related to increased limb and head blood velocity, flow and kinetic energy. The findings indicate that local thermosensitive mechanisms modulate regional blood velocity, flow and kinetic energy, thereby controlling the magnitude of flow to the heart and thus the coupling of peripheral and central circulation during hyperthermia.
Collapse
Affiliation(s)
- Kazuhito Watanabe
- Division of Sport, Health and Exercise Sciences, Department of Life Sciences, Brunel University London, Uxbridge, UK
- Faculty of Education and Human Studies, Akita University, Akita, Japan
| | - Nuno Koch Esteves
- Division of Sport, Health and Exercise Sciences, Department of Life Sciences, Brunel University London, Uxbridge, UK
- Research Centre, University College of Osteopathy, London, UK
| | - Oliver R Gibson
- Division of Sport, Health and Exercise Sciences, Department of Life Sciences, Brunel University London, Uxbridge, UK
- Centre for Physical Activity in Health and Disease, Brunel University London, Uxbridge, UK
| | - Koichi Akiyama
- Department of Anesthesiology, Kindai University Hospital, Osaka, Japan
| | - Sumie Watanabe
- Division of Sport, Health and Exercise Sciences, Department of Life Sciences, Brunel University London, Uxbridge, UK
- Faculty of Education and Human Studies, Akita University, Akita, Japan
| | - José González-Alonso
- Division of Sport, Health and Exercise Sciences, Department of Life Sciences, Brunel University London, Uxbridge, UK
| |
Collapse
|
3
|
Koch Esteves N, Khir AW, González‐Alonso J. Lower limb hyperthermia augments functional hyperaemia during small muscle mass exercise similarly in trained elderly and young humans. Exp Physiol 2023; 108:1154-1171. [PMID: 37409754 PMCID: PMC10988472 DOI: 10.1113/ep091275] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 06/23/2023] [Indexed: 07/07/2023]
Abstract
NEW FINDINGS What is the central question of the study? Ageing is postulated to lead to underperfusion of human limb tissues during passive and exertional hyperthermia, but findings to date have been equivocal. Thus, does age have an independent adverse effect on local haemodynamics during passive single-leg hyperthermia, single-leg knee-extensor exercise and their combination? What is the main finding and its importance? Local hyperthermia increased leg blood flow over three-fold and had an additive effect during knee-extensor exercise with no absolute differences in leg perfusion between the healthy, exercise-trained elderly and the young groups. Our findings indicate that age per se does not compromise lower limb hyperaemia during local hyperthermia and/or small muscle mass exercise. ABSTRACT Heat and exercise therapies are recommended to improve vascular health across the lifespan. However, the haemodynamic effects of hyperthermia, exercise and their combination are inconsistent in young and elderly people. Here we investigated the acute effects of local-limb hyperthermia and exercise on limb haemodynamics in nine healthy, trained elderly (69 ± 5 years) and 10 young (26 ± 7 years) adults, hypothesising that the combination of local hyperthermia and exercise interact to increase leg perfusion, albeit to a lesser extent in the elderly. Participants underwent 90 min of single whole-leg heating, with the contralateral leg remaining as control, followed by 10 min of low-intensity incremental single-leg knee-extensor exercise with both the heated and control legs. Temperature profiles and leg haemodynamics at the femoral and popliteal arteries were measured. In both groups, heating increased whole-leg skin temperature and blood flow by 9.5 ± 1.2°C and 0.7 ± 0.2 L min-1 (>3-fold), respectively (P < 0.0001). Blood flow in the heated leg remained 0.7 ± 0.6 and 1.0 ± 0.8 L min-1 higher during exercise at 6 and 12 W, respectively (P < 0.0001). However, there were no differences in limb haemodynamics between cohorts, other than the elderly group exhibiting a 16 ± 6% larger arterial diameter and a 51 ± 6% lower blood velocity following heating (P < 0.0001). In conclusion, local hyperthermia-induced limb hyperperfusion and/or small muscle mass exercise hyperaemia are preserved in trained older people despite evident age-related structural and functional alterations in their leg conduit arteries.
Collapse
Affiliation(s)
- Nuno Koch Esteves
- Division of Sport, Health, and Exercise Sciences, Department of Life SciencesBrunel University LondonUxbridgeUK
| | | | - José González‐Alonso
- Division of Sport, Health, and Exercise Sciences, Department of Life SciencesBrunel University LondonUxbridgeUK
| |
Collapse
|
4
|
Grigorev GV, Lebedev AV, Wang X, Qian X, Maksimov GV, Lin L. Advances in Microfluidics for Single Red Blood Cell Analysis. BIOSENSORS 2023; 13:117. [PMID: 36671952 PMCID: PMC9856164 DOI: 10.3390/bios13010117] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/04/2022] [Accepted: 12/23/2022] [Indexed: 05/24/2023]
Abstract
The utilizations of microfluidic chips for single RBC (red blood cell) studies have attracted great interests in recent years to filter, trap, analyze, and release single erythrocytes for various applications. Researchers in this field have highlighted the vast potential in developing micro devices for industrial and academia usages, including lab-on-a-chip and organ-on-a-chip systems. This article critically reviews the current state-of-the-art and recent advances of microfluidics for single RBC analyses, including integrated sensors and microfluidic platforms for microscopic/tomographic/spectroscopic single RBC analyses, trapping arrays (including bifurcating channels), dielectrophoretic and agglutination/aggregation studies, as well as clinical implications covering cancer, sepsis, prenatal, and Sickle Cell diseases. Microfluidics based RBC microarrays, sorting/counting and trapping techniques (including acoustic, dielectrophoretic, hydrodynamic, magnetic, and optical techniques) are also reviewed. Lastly, organs on chips, multi-organ chips, and drug discovery involving single RBC are described. The limitations and drawbacks of each technology are addressed and future prospects are discussed.
Collapse
Affiliation(s)
- Georgii V. Grigorev
- Data Science and Information Technology Research Center, Tsinghua Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518055, China
- Mechanical Engineering Department, University of California in Berkeley, Berkeley, CA 94720, USA
- School of Information Technology, Cherepovets State University, 162600 Cherepovets, Russia
| | - Alexander V. Lebedev
- Machine Building Department, Bauman Moscow State University, 105005 Moscow, Russia
| | - Xiaohao Wang
- Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Xiang Qian
- Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - George V. Maksimov
- Faculty of Biology, Lomonosov Moscow State University, 119991 Moscow, Russia
- Physical metallurgy Department, Federal State Autonomous Educational Institution of Higher Education National Research Technological University “MISiS”, 119049 Moscow, Russia
| | - Liwei Lin
- Mechanical Engineering Department, University of California in Berkeley, Berkeley, CA 94720, USA
| |
Collapse
|
5
|
Koch Esteves N, Gibson OR, Khir AW, González‐Alonso J. Regional thermal hyperemia in the human leg: Evidence of the importance of thermosensitive mechanisms in the control of the peripheral circulation. Physiol Rep 2021; 9:e14953. [PMID: 34350727 PMCID: PMC8339537 DOI: 10.14814/phy2.14953] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 06/13/2021] [Accepted: 06/15/2021] [Indexed: 02/04/2023] Open
Abstract
Hyperthermia is thought to increase limb blood flow through the activation of thermosensitive mechanisms within the limb vasculature, but the precise vascular locus in which hyperthermia modulates perfusion remains elusive. We tested the hypothesis that local temperature-sensitive mechanisms alter limb hemodynamics by regulating microvascular blood flow. Temperature and oxygenation profiles and leg hemodynamics of the common (CFA), superficial (SFA) and profunda (PFA) femoral arteries, and popliteal artery (POA) of the experimental and control legs were measured in healthy participants during: (1) 3 h of whole leg heating (WLH) followed by 3 h of recovery (n = 9); (2) 1 h of upper leg heating (ULH) followed by 30 min of cooling and 1 h ULH bout (n = 8); and (3) 1 h of lower leg heating (LLH) (n = 8). WLH increased experimental leg temperature by 4.2 ± 1.2ºC and blood flow in CFA, SFA, PFA, and POA by ≥3-fold, while the core temperature essentially remained stable. Upper and lower leg blood flow increased exponentially in response to leg temperature and then declined during recovery. ULH and LLH similarly increased the corresponding segmental leg temperature, blood flow, and tissue oxygenation without affecting these responses in the non-heated leg segment, or perfusion pressure and conduit artery diameter across all vessels. Findings demonstrate that whole leg hyperthermia induces profound and sustained elevations in upper and lower limb blood flow and that segmental hyperthermia matches the regional thermal hyperemia without causing thermal or hemodynamic alterations in the non-heated limb segment. These observations support the notion that heat-activated thermosensitive mechanisms in microcirculation regulate limb tissue perfusion during hyperthermia.
Collapse
Affiliation(s)
- Nuno Koch Esteves
- Centre for Human Performance, Exercise and RehabilitationCollege of Health, Medicine and Life SciencesBrunel University LondonUxbridgeUK
| | - Oliver R. Gibson
- Centre for Human Performance, Exercise and RehabilitationCollege of Health, Medicine and Life SciencesBrunel University LondonUxbridgeUK
- Division of Sport, Health and Exercise SciencesDepartment of Life SciencesCollege of Health, Medicine and Life SciencesBrunel University LondonUxbridgeUK
| | - Ashraf W. Khir
- Department of Mechanical and Aerospace EngineeringCollege of Engineering, Design and Physical SciencesBrunel University LondonUxbridgeUK
| | - José González‐Alonso
- Centre for Human Performance, Exercise and RehabilitationCollege of Health, Medicine and Life SciencesBrunel University LondonUxbridgeUK
- Division of Sport, Health and Exercise SciencesDepartment of Life SciencesCollege of Health, Medicine and Life SciencesBrunel University LondonUxbridgeUK
| |
Collapse
|
6
|
Carvalho V, Gonçalves IM, Souza A, Souza MS, Bento D, Ribeiro JE, Lima R, Pinho D. Manual and Automatic Image Analysis Segmentation Methods for Blood Flow Studies in Microchannels. MICROMACHINES 2021; 12:317. [PMID: 33803615 PMCID: PMC8002955 DOI: 10.3390/mi12030317] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Revised: 03/12/2021] [Accepted: 03/14/2021] [Indexed: 01/16/2023]
Abstract
In blood flow studies, image analysis plays an extremely important role to examine raw data obtained by high-speed video microscopy systems. This work shows different ways to process the images which contain various blood phenomena happening in microfluidic devices and in microcirculation. For this purpose, the current methods used for tracking red blood cells (RBCs) flowing through a glass capillary and techniques to measure the cell-free layer thickness in different kinds of microchannels will be presented. Most of the past blood flow experimental data have been collected and analyzed by means of manual methods, that can be extremely reliable, but they are highly time-consuming, user-intensive, repetitive, and the results can be subjective to user-induced errors. For this reason, it is crucial to develop image analysis methods able to obtain the data automatically. Concerning automatic image analysis methods for individual RBCs tracking and to measure the well known microfluidic phenomena cell-free layer, two developed methods are presented and discussed in order to demonstrate their feasibility to obtain accurate data acquisition in such studies. Additionally, a comparison analysis between manual and automatic methods was performed.
Collapse
Affiliation(s)
- Violeta Carvalho
- Mechanical Engineering and Resource Sustainability Center (MEtRICs), Mechanical Engineering Department, University of Minho, 4800-058 Guimarães, Portugal; (V.C.); (D.P.)
| | - Inês M. Gonçalves
- Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal;
| | - Andrews Souza
- Centro para a Valorização de Resíduos (CVR), University of Minho, 4800-028 Guimarães, Portugal;
| | - Maria S. Souza
- Center for MicroElectromechanical Systems (CMEMS), University of Minho, 4800-058 Guimarães, Portugal;
| | - David Bento
- Transport Phenomena Research Center (CEFT), Faculdade de Engenharia da Universidade do Porto (FEUP), Rua Dr. Roberto Frias, 4200-465 Porto, Portugal;
- Polytechnic Institute of Bragança, ESTiG/IPB, C. Sta. Apolónia, 5300-857 Bragança, Portugal;
| | - João E. Ribeiro
- Polytechnic Institute of Bragança, ESTiG/IPB, C. Sta. Apolónia, 5300-857 Bragança, Portugal;
- Centro de Investigação de Montanha (CIMO), Polytechnic Institute of Bragança, 5300-252, Bragança, Portugal
| | - Rui Lima
- Mechanical Engineering and Resource Sustainability Center (MEtRICs), Mechanical Engineering Department, University of Minho, 4800-058 Guimarães, Portugal; (V.C.); (D.P.)
- Transport Phenomena Research Center (CEFT), Faculdade de Engenharia da Universidade do Porto (FEUP), Rua Dr. Roberto Frias, 4200-465 Porto, Portugal;
| | - Diana Pinho
- Mechanical Engineering and Resource Sustainability Center (MEtRICs), Mechanical Engineering Department, University of Minho, 4800-058 Guimarães, Portugal; (V.C.); (D.P.)
- Center for MicroElectromechanical Systems (CMEMS), University of Minho, 4800-058 Guimarães, Portugal;
- Polytechnic Institute of Bragança, ESTiG/IPB, C. Sta. Apolónia, 5300-857 Bragança, Portugal;
| |
Collapse
|
7
|
3D Printed Biomodels for Flow Visualization in Stenotic Vessels: An Experimental and Numerical Study. MICROMACHINES 2020; 11:mi11060549. [PMID: 32485816 PMCID: PMC7344925 DOI: 10.3390/mi11060549] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 05/17/2020] [Accepted: 05/25/2020] [Indexed: 12/13/2022]
Abstract
Atherosclerosis is one of the most serious and common forms of cardiovascular disease and a major cause of death and disability worldwide. It is a multifactorial and complex disease that promoted several hemodynamic studies. Although in vivo studies more accurately represent the physiological conditions, in vitro experiments more reliably control several physiological variables and most adequately validate numerical flow studies. Here, a hemodynamic study in idealized stenotic and healthy coronary arteries is presented by applying both numerical and in vitro approaches through computational fluid dynamics simulations and a high-speed video microscopy technique, respectively. By means of stereolithography 3D printing technology, biomodels with three different resolutions were used to perform experimental flow studies. The results showed that the biomodel printed with a resolution of 50 μm was able to most accurately visualize flow due to its lowest roughness values (Ra = 1.8 μm). The flow experimental results showed a qualitatively good agreement with the blood flow numerical data, providing a clear observation of recirculation regions when the diameter reduction reached 60%.
Collapse
|
8
|
Connolly S, Newport D, McGourty K. The mechanical responses of advecting cells in confined flow. BIOMICROFLUIDICS 2020; 14:031501. [PMID: 32454924 PMCID: PMC7200165 DOI: 10.1063/5.0005154] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 04/21/2020] [Indexed: 05/03/2023]
Abstract
Fluid dynamics have long influenced cells in suspension. Red blood cells and white blood cells are advected through biological microchannels in both the cardiovascular and lymphatic systems and, as a result, are subject to a wide variety of complex fluidic forces as they pass through. In vivo, microfluidic forces influence different biological processes such as the spreading of infection, cancer metastasis, and cell viability, highlighting the importance of fluid dynamics in the blood and lymphatic vessels. This suggests that in vitro devices carrying cell suspensions may influence the viability and functionality of cells. Lab-on-a-chip, flow cytometry, and cell therapies involve cell suspensions flowing through microchannels of approximately 100-800 μ m. This review begins by examining the current fundamental theories and techniques behind the fluidic forces and inertial focusing acting on cells in suspension, before exploring studies that have investigated how these fluidic forces affect the reactions of suspended cells. In light of these studies' findings, both in vivo and in vitro fluidic cell microenvironments shall also be discussed before concluding with recommendations for the field.
Collapse
Affiliation(s)
- S Connolly
- School of Engineering, Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland
| | - D Newport
- School of Engineering, Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland
| | | |
Collapse
|
9
|
Bento D, Lopes S, Maia I, Lima R, Miranda JM. Bubbles Moving in Blood Flow in a Microchannel Network: The Effect on the Local Hematocrit. MICROMACHINES 2020; 11:mi11040344. [PMID: 32224993 PMCID: PMC7230880 DOI: 10.3390/mi11040344] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 03/23/2020] [Accepted: 03/23/2020] [Indexed: 01/07/2023]
Abstract
Air inside of blood vessels is a phenomenon known as gas embolism. During the past years, studies have been performed to assess the influence of air bubbles in microcirculation. In this study, we investigated the flow of bubbles in a microchannel network with several bifurcations, mimicking part of a capillary system. Thus, two working fluids were used, composed by sheep red blood cells (RBCs) suspended in a Dextran 40 solution with different hematocrits (5% and 10%). The experiments were carried out in a polydimethylsiloxane (PDMS) microchannel network fabricated by a soft lithography. A high-speed video microscopy system was used to obtain the results for a blood flow rate of 10 µL/min. This system enables the visualization of bubble formation and flow along the network. The results showed that the passage of air bubbles strongly influences the cell's local concentration, since a higher concentration of cells was observed upstream of the bubble, whereas a lower local hematocrit was visualized at the region downstream of the bubble. In bifurcations, bubbles may split asymmetrically, leading to an uneven distribution of RBCs between the outflow branches.
Collapse
Affiliation(s)
- David Bento
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (D.B.); (R.L.)
- Polytechnic Institute of Bragança, ESTiG/IPB, C. Sta. Apolónia, 5300-857 Bragança, Portugal;
| | - Sara Lopes
- Polytechnic Institute of Bragança, ESTiG/IPB, C. Sta. Apolónia, 5300-857 Bragança, Portugal;
| | - Inês Maia
- Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal;
| | - Rui Lima
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (D.B.); (R.L.)
- MEtRICS, Mechanical Eng. Dep., University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal
| | - João M. Miranda
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (D.B.); (R.L.)
- Correspondence:
| |
Collapse
|
10
|
Hong JK, Gao L, Singh J, Goh T, Ruhoff AM, Neto C, Waterhouse A. Evaluating medical device and material thrombosis under flow: current and emerging technologies. Biomater Sci 2020; 8:5824-5845. [DOI: 10.1039/d0bm01284j] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
This review highlights the importance of flow in medical device thrombosis and explores current and emerging technologies to evaluate dynamic biomaterial Thrombosis in vitro.
Collapse
Affiliation(s)
- Jun Ki Hong
- School of Chemistry
- The University of Sydney
- Australia
- School of Medical Sciences
- Faculty of Medicine and Health
| | - Lingzi Gao
- Heart Research Institute
- Newtown
- Australia
- The University of Sydney Nano Institute
- The University of Sydney
| | - Jasneil Singh
- Heart Research Institute
- Newtown
- Australia
- The Charles Perkins Centre
- The University of Sydney
| | - Tiffany Goh
- Heart Research Institute
- Newtown
- Australia
- The Charles Perkins Centre
- The University of Sydney
| | - Alexander M. Ruhoff
- Heart Research Institute
- Newtown
- Australia
- The Charles Perkins Centre
- The University of Sydney
| | - Chiara Neto
- School of Chemistry
- The University of Sydney
- Australia
- The University of Sydney Nano Institute
- The University of Sydney
| | - Anna Waterhouse
- School of Medical Sciences
- Faculty of Medicine and Health
- The University of Sydney
- Australia
- Heart Research Institute
| |
Collapse
|
11
|
A Microfluidic Deformability Assessment of Pathological Red Blood Cells Flowing in a Hyperbolic Converging Microchannel. MICROMACHINES 2019; 10:mi10100645. [PMID: 31557932 PMCID: PMC6843121 DOI: 10.3390/mi10100645] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2019] [Revised: 09/20/2019] [Accepted: 09/24/2019] [Indexed: 12/25/2022]
Abstract
The loss of the red blood cells (RBCs) deformability is related with many human diseases, such as malaria, hereditary spherocytosis, sickle cell disease, or renal diseases. Hence, during the last years, a variety of technologies have been proposed to gain insights into the factors affecting the RBCs deformability and their possible direct association with several blood pathologies. In this work, we present a simple microfluidic tool that provides the assessment of motions and deformations of RBCs of end-stage kidney disease (ESKD) patients, under a well-controlled microenvironment. All of the flow studies were performed within a hyperbolic converging microchannels where single-cell deformability was assessed under a controlled homogeneous extensional flow field. By using a passive microfluidic device, RBCs passing through a hyperbolic-shaped contraction were measured by a high-speed video microscopy system, and the velocities and deformability ratios (DR) calculated. Blood samples from 27 individuals, including seven healthy controls and 20 having ESKD with or without diabetes, were analysed. The obtained data indicates that the proposed device is able to detect changes in DR of the RBCs, allowing for distinguishing the samples from the healthy controls and the patients. Overall, the deformability of ESKD patients with and without diabetes type II is lower in comparison with the RBCs from the healthy controls, with this difference being more evident for the group of ESKD patients with diabetes. RBCs from ESKD patients without diabetes elongate on average 8% less, within the hyperbolic contraction, as compared to healthy controls; whereas, RBCs from ESKD patients with diabetes elongate on average 14% less than the healthy controls. The proposed strategy can be easily transformed into a simple and inexpensive diagnostic microfluidic system to assess blood cells deformability due to the huge progress in image processing and high-speed microvisualization technology.
Collapse
|
12
|
Catarino SO, Rodrigues RO, Pinho D, Miranda JM, Minas G, Lima R. Blood Cells Separation and Sorting Techniques of Passive Microfluidic Devices: From Fabrication to Applications. MICROMACHINES 2019; 10:mi10090593. [PMID: 31510012 PMCID: PMC6780402 DOI: 10.3390/mi10090593] [Citation(s) in RCA: 60] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Revised: 09/03/2019] [Accepted: 09/06/2019] [Indexed: 01/23/2023]
Abstract
Since the first microfluidic device was developed more than three decades ago, microfluidics is seen as a technology that exhibits unique features to provide a significant change in the way that modern biology is performed. Blood and blood cells are recognized as important biomarkers of many diseases. Taken advantage of microfluidics assets, changes on blood cell physicochemical properties can be used for fast and accurate clinical diagnosis. In this review, an overview of the microfabrication techniques is given, especially for biomedical applications, as well as a synopsis of some design considerations regarding microfluidic devices. The blood cells separation and sorting techniques were also reviewed, highlighting the main achievements and breakthroughs in the last decades.
Collapse
Affiliation(s)
- Susana O Catarino
- Center for MicroElectromechanical Systems (CMEMS-UMinho), University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal
| | - Raquel O Rodrigues
- Center for MicroElectromechanical Systems (CMEMS-UMinho), University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal
| | - Diana Pinho
- Research Centre in Digitalization and Intelligent Robotics (CeDRI), Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP), Rua Roberto Frias, 4200-465 Porto, Portugal
| | - João M Miranda
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP), Rua Roberto Frias, 4200-465 Porto, Portugal
| | - Graça Minas
- Center for MicroElectromechanical Systems (CMEMS-UMinho), University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal
| | - Rui Lima
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP), Rua Roberto Frias, 4200-465 Porto, Portugal.
- MEtRICs, Mechanical Engineering Department, University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal.
| |
Collapse
|
13
|
Microfluidic Deformability Study of an Innovative Blood Analogue Fluid Based on Giant Unilamellar Vesicles. J Funct Biomater 2018; 9:jfb9040070. [PMID: 30518160 PMCID: PMC6306889 DOI: 10.3390/jfb9040070] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2018] [Revised: 11/12/2018] [Accepted: 11/27/2018] [Indexed: 11/16/2022] Open
Abstract
Blood analogues have long been a topic of interest in biofluid mechanics due to the safety and ethical issues involved in the collection and handling of blood samples. Although the current blood analogue fluids can adequately mimic the rheological properties of blood from a macroscopic point of view, at the microscopic level blood analogues need further development and improvement. In this work, an innovative blood analogue containing giant unilamellar vesicles (GUVs) was developed to mimic the flow behavior of red blood cells (RBCs). A natural lipid mixture, soybean lecithin, was used for the GUVs preparation, and three different lipid concentrations were tested (1 × 10-3 M, 2 × 10-3 M and 4 × 10-3 M). GUV solutions were prepared by thin film hydration with a buffer, followed by extrusion. It was found that GUVs present diameters between 5 and 7 µm which are close to the size of human RBCs. Experimental flow studies of three different GUV solutions were performed in a hyperbolic-shaped microchannel in order to measure the GUVs deformability when subjected to a homogeneous extensional flow. The result of the deformation index (DI) of the GUVs was about 0.5, which is in good agreement with the human RBC's DI. Hence, the GUVs developed in this study are a promising way to mimic the mechanical properties of the RBCs and to further develop particulate blood analogues with flow properties closer to those of real blood.
Collapse
|
14
|
Local Hematocrit Fluctuation Induced by Malaria-Infected Red Blood Cells and Its Effect on Microflow. BIOMED RESEARCH INTERNATIONAL 2018; 2018:8065252. [PMID: 29850568 PMCID: PMC5937607 DOI: 10.1155/2018/8065252] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Revised: 03/06/2018] [Accepted: 03/13/2018] [Indexed: 11/17/2022]
Abstract
We investigate numerically the microscale blood flow in which red blood cells (RBCs) are partially infected by Plasmodium falciparum, the malaria parasite. The infected RBCs are modeled as more rigid cells with less deformability than healthy ones. Our study illustrates that, in a 10 μm microvessel in low-hematocrit conditions (18% and 27%), the Plasmodium falciparum-infected red blood cells (Pf-IRBCs) and healthy ones first form a train of cells. Because of the slow moving of the Pf-IRBCs, the local hematocrit (Hct) near the Pf-IRBCs is then increased, to approximately 40% or even higher values. This increase of the local hematocrit is temporary and is kept for a longer length of time because of the long RBC train formed in 27%-Hct condition. Similar hematocrit elevation at the downstream region with 45%-Hct in the same 10 μm microvessel is also observed with the cells randomly located. In 20 μm microvessels with 45%-Hct, the Pf-IRBCs slow down the velocity of the healthy red blood cells (HRBCs) around them and then locally elevate the volume fraction and result in the accumulation of the RBCs at the center of the vessels, thus leaving a thicker cell free layer (CFL) near the vessel wall than normal. Variation of wall shear stress (WSS) is caused by the fluctuation of local Hct and the distance between the wall and the RBCs. Moreover, in high-hematocrit condition (45%), malaria-infected cells have a tendency to migrate to the edge of the aggregates which is due to the uninterrupted hydrodynamic interaction between the HRBCs and Pf-IRBC. Our results suggest that the existence of Pf-IRBCs is a nonnegligible factor for the fluctuation of hematocrit and WSS and also contributes to the increase of CFL of pathological blood flow in microvessels. The numerical approach presented has the potential to be utilized to RBC disorders and other hematologic diseases.
Collapse
|
15
|
Bento D, Rodrigues RO, Faustino V, Pinho D, Fernandes CS, Pereira AI, Garcia V, Miranda JM, Lima R. Deformation of Red Blood Cells, Air Bubbles, and Droplets in Microfluidic Devices: Flow Visualizations and Measurements. MICROMACHINES 2018; 9:E151. [PMID: 30424085 PMCID: PMC6187860 DOI: 10.3390/mi9040151] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2018] [Revised: 03/21/2018] [Accepted: 03/21/2018] [Indexed: 12/30/2022]
Abstract
Techniques, such as micropipette aspiration and optical tweezers, are widely used to measure cell mechanical properties, but are generally labor-intensive and time-consuming, typically involving a difficult process of manipulation. In the past two decades, a large number of microfluidic devices have been developed due to the advantages they offer over other techniques, including transparency for direct optical access, lower cost, reduced space and labor, precise control, and easy manipulation of a small volume of blood samples. This review presents recent advances in the development of microfluidic devices to evaluate the mechanical response of individual red blood cells (RBCs) and microbubbles flowing in constriction microchannels. Visualizations and measurements of the deformation of RBCs flowing through hyperbolic, smooth, and sudden-contraction microchannels were evaluated and compared. In particular, we show the potential of using hyperbolic-shaped microchannels to precisely control and assess small changes in RBC deformability in both physiological and pathological situations. Moreover, deformations of air microbubbles and droplets flowing through a microfluidic constriction were also compared with RBCs deformability.
Collapse
Affiliation(s)
- David Bento
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
| | - Raquel O Rodrigues
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
- LCM-Laboratory of Catalysis and Materials-Associate Laboratory LSRE/LCM, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
| | - Vera Faustino
- MEMS-UMinho Research Unit, Universidade do Minho, DEI, Campus de Azurém, 4800-058 Guimarães, Portugal.
| | - Diana Pinho
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
- Centro de Investigação em Digitalização e Robótica Inteligente (CeDRI), Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal.
| | - Carla S Fernandes
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
| | - Ana I Pereira
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
- Centro de Investigação em Digitalização e Robótica Inteligente (CeDRI), Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal.
- Algoritmi R&D Centre, Campus de Gualtar, University of Minho, 4710-057 Braga, Portugal.
| | - Valdemar Garcia
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
| | - João M Miranda
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
| | - Rui Lima
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
- MEtRiCS, Mechanical Engineering Department, Campus de Azurém, University of Minho, 4800-058 Guimarães, Portugal.
| |
Collapse
|
16
|
Chuang CH, Kikuchi K, Ueno H, Numayama-Tsuruta K, Yamaguchi T, Ishikawa T. Collective spreading of red blood cells flowing in a microchannel. J Biomech 2018; 69:64-69. [PMID: 29397999 DOI: 10.1016/j.jbiomech.2018.01.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Revised: 12/19/2017] [Accepted: 01/08/2018] [Indexed: 11/27/2022]
Abstract
Due to recent advances in micro total analysis system technologies, microfluidics provides increased opportunities to manipulate, stimulate, and diagnose blood cells. Controlling the concentration of cells at a given position across the width of a channel is an important aspect in the design of microfluidic devices. Despite its biomedical importance, the collective spreading of red blood cells (RBCs) in a microchannel has not yet been fully clarified. In this study, we experimentally investigated the collective spreading of RBCs in a straight microchannel, and found that RBCs initially distributed in one side of the microchannel spread to the spanwise direction during downstream flow. Spreading increased considerably as the hematocrit increased, though the flow rate had a small effect. We proposed a scaling argument to show that this spreading phenomenon was diffusive and mainly induced by cell-cell interactions. The dispersion coefficient was approximately proportional to the flow rate and the hematocrit. These results are useful in understanding collective behaviors of RBCs in a microchannel and in microcirculation.
Collapse
Affiliation(s)
- Cheng-Hsi Chuang
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan
| | - Kenji Kikuchi
- Dept. Finemechanics, Graduate School of Engineering, Tohoku University, Sendai, Japan
| | - Hironori Ueno
- Dept. Molecular Function and Life Science, Aichi University of Education, Kariya, Japan
| | | | - Takami Yamaguchi
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan
| | - Takuji Ishikawa
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan; Dept. Finemechanics, Graduate School of Engineering, Tohoku University, Sendai, Japan.
| |
Collapse
|
17
|
Pinho D, Campo-Deaño L, Lima R, Pinho FT. In vitro particulate analogue fluids for experimental studies of rheological and hemorheological behavior of glucose-rich RBC suspensions. BIOMICROFLUIDICS 2017; 11:054105. [PMID: 28966701 PMCID: PMC5608610 DOI: 10.1063/1.4998190] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2017] [Accepted: 07/28/2017] [Indexed: 05/09/2023]
Abstract
Suspensions of healthy and pathological red blood cells (RBC) flowing in microfluidic devices are frequently used to perform in vitro blood experiments for a better understanding of human microcirculation hemodynamic phenomena. This work reports the development of particulate viscoelastic analogue fluids able to mimic the rheological and hemorheological behavior of pathological RBC suspensions flowing in microfluidic systems. The pathological RBCs were obtained by an incubation of healthy RBCs at a high concentration of glucose, representing the pathological stage of hyperglycaemia in diabetic complications, and analyses of their deformability and aggregation were carried out. Overall, the developed in vitro analogue fluids were composed of a suspension of semi-rigid microbeads in a carrier viscoelastic fluid made of dextran 40 and xanthan gum. All suspensions of healthy and pathological RBCs, as well as their particulate analogue fluids, were extensively characterized in steady shear flow, as well as in small and large amplitude oscillatory shear flow. In addition, the well-known cell-free layer (CFL) phenomenon occurring in microchannels was investigated in detail to provide comparisons between healthy and pathological in vitro RBC suspensions and their corresponding analogue fluids at different volume concentrations (5% and 20%). The experimental results have shown a similar rheological behavior between the samples containing a suspension of pathological RBCs and the proposed analogue fluids. Moreover, this work shows that the particulate in vitro analogue fluids used have the ability to mimic well the CFL phenomenon occurring downstream of a microchannel contraction for pathological RBC suspensions. The proposed particulate fluids provide a more realistic behavior of the flow properties of suspended RBCs when compared with existing non-particulate blood analogues, and consequently, they are advantageous for detailed investigations of microcirculation.
Collapse
Affiliation(s)
| | - Laura Campo-Deaño
- CEFT, DEMec, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | | | - Fernando T Pinho
- CEFT, DEMec, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| |
Collapse
|
18
|
Stauber H, Waisman D, Korin N, Sznitman J. Red blood cell (RBC) suspensions in confined microflows: Pressure-flow relationship. Med Eng Phys 2017; 48:49-54. [PMID: 28838798 DOI: 10.1016/j.medengphy.2017.08.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Revised: 07/12/2017] [Accepted: 08/09/2017] [Indexed: 11/28/2022]
Abstract
Microfluidic-based assays have become increasingly popular to explore microcirculation in vitro. In these experiments, blood is resuspended to a desired haematocrit level in a buffer solution, where frequent choices for preparing RBC suspensions comprise notably Dextran and physiological buffer. Yet, the rational for selecting one buffer versus another is often ill-defined and lacks detailed quantification, including ensuing changes in RBC flow characteristics. Here, we revisit RBC suspensions in microflows and attempt to quantify systematically some of the differences emanating between buffers. We measure bulk flow rate (Q) of RBC suspensions, using PBS- and Dextran-40, as a function of the applied pressure drop (ΔP) for two hematocrits (∼0% and 23%). Two distinct microfluidic designs of varying dimensions are employed: a straight channel larger than and a network array similar to the size of individual RBCs. Using the resulting pressure-flow curves, we extract the equivalent hydrodynamic resistances and estimate the relative viscosities. These efforts are a first step in rigorously quantifying the influence of the 'background' buffer on RBC flows within microfluidic devices and thereby underline the importance of purposefully selecting buffer suspensions for microfluidic in vitro assays.
Collapse
Affiliation(s)
- Hagit Stauber
- Department of Biomedical Engineering, Technion - Israel Institute of Technology, 3200003 Haifa, Israel
| | - Dan Waisman
- Department of Neonatology, Carmel Medical Center, 3436212 Haifa, Israel; Faculty of Medicine, Technion - Israel Institute of Technology, 3200003 Haifa, Israel
| | - Netanel Korin
- Department of Biomedical Engineering, Technion - Israel Institute of Technology, 3200003 Haifa, Israel
| | - Josué Sznitman
- Department of Biomedical Engineering, Technion - Israel Institute of Technology, 3200003 Haifa, Israel.
| |
Collapse
|
19
|
Bento D, Pereira AI, Lima J, Miranda JM, Lima R. Cell-free layer measurements ofin vitroblood flow in a microfluidic network: an automatic and manual approach. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION 2017. [DOI: 10.1080/21681163.2017.1329029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- D. Bento
- School of Technology and Management (ESTiG), Polytechnic Institute of Bragança (IPB), Bragança, Portugal
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP), Porto, Portugal
| | - A. I. Pereira
- School of Technology and Management (ESTiG), Polytechnic Institute of Bragança (IPB), Bragança, Portugal
- Algoritmi R & D Centre, University of Minho, Braga, Portugal
| | - J. Lima
- School of Technology and Management (ESTiG), Polytechnic Institute of Bragança (IPB), Bragança, Portugal
- INESC TEC – Centre for Robotics in Industry and Intelligent Systems, Porto, Portugal
| | - J. M. Miranda
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP), Porto, Portugal
| | - R. Lima
- School of Technology and Management (ESTiG), Polytechnic Institute of Bragança (IPB), Bragança, Portugal
- MEtRiCS, Mechanical Engineering Department, University of Minho, Guimarães, Portugal
| |
Collapse
|
20
|
Stauber H, Waisman D, Korin N, Sznitman J. Red blood cell dynamics in biomimetic microfluidic networks of pulmonary alveolar capillaries. BIOMICROFLUIDICS 2017; 11:014103. [PMID: 28090238 PMCID: PMC5234697 DOI: 10.1063/1.4973930] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Accepted: 12/29/2016] [Indexed: 05/21/2023]
Abstract
The pulmonary capillary networks (PCNs) embody organ-specific microvasculatures, where blood vessels form dense meshes that maximize the surface area available for gas exchange in the lungs. With characteristic capillary lengths and diameters similar to the size of red blood cells (RBCs), seminal descriptions coined the term "sheet flow" nearly half a century ago to differentiate PCNs from the usual notion of Poiseuille flow in long straight tubes. Here, we revisit in true-scale experiments the original "sheet flow" model and devise for the first time biomimetic microfluidic platforms of organ-specific PCN structures perfused with RBC suspensions at near-physiological hematocrit levels. By implementing RBC tracking velocimetry, our measurements reveal a wide range of heterogonous RBC pathways that coexist synchronously within the PCN; a phenomenon that persists across the broad range of pressure drops and capillary segment sizes investigated. Interestingly, in spite of the intrinsic complexity of the PCN structure and the heterogeneity in RBC dynamics observed at the microscale, the macroscale bulk flow rate versus pressure drop relationship retains its linearity, where the hydrodynamic resistance of the PCN is to a first order captured by the characteristic capillary segment size. To the best of our knowledge, our in vitro efforts constitute a first, yet significant, step in exploring systematically the transport dynamics of blood in morphologically inspired capillary networks.
Collapse
Affiliation(s)
- Hagit Stauber
- Department of Biomedical Engineering, Technion - Israel Institute of Technology, 3200003 Haifa, Israel
| | - Dan Waisman
- Department of Neonatology, Carmel Medical Center, 3436212 Haifa, Israel; Faculty of Medicine, Technion - Israel Institute of Technology, 3200003 Haifa, Israel
| | - Netanel Korin
- Department of Biomedical Engineering, Technion - Israel Institute of Technology, 3200003 Haifa, Israel
| | - Josué Sznitman
- Department of Biomedical Engineering, Technion - Israel Institute of Technology, 3200003 Haifa, Israel
| |
Collapse
|
21
|
Particulate Blood Analogues Reproducing the Erythrocytes Cell-Free Layer in a Microfluidic Device Containing a Hyperbolic Contraction. MICROMACHINES 2015; 7:mi7010004. [PMID: 30407376 PMCID: PMC6189708 DOI: 10.3390/mi7010004] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2015] [Revised: 12/21/2015] [Accepted: 12/22/2015] [Indexed: 11/17/2022]
Abstract
The interest in the development of blood analogues has been increasing recently as a consequence of the increment in the number of experimental hemodynamic studies and the difficulties associated with the manipulation of real blood in vitro because of ethical, economical or hazardous issues. Although one-phase Newtonian and non-Newtonian blood analogues can be found in the literature, there are very few studies related to the use of particulate solutions in which the particles mimic the behaviour of the red blood cells (RBCs) or erythrocytes. One of the most relevant effects related with the behaviour of the erythrocytes is a cell-free layer (CFL) formation, which consists in the migration of the RBCs towards the center of the vessel forming a cell depleted plasma region near the vessel walls, which is known to happen in in vitro microcirculatory environments. Recent studies have shown that the CFL enhancement is possible with an insertion of contraction and expansion region in a straight microchannel. These effects are useful for cell manipulation or sorting in lab-on-chip studies. In this experimental study we present particulate Newtonian and non-Newtonian solutions which resulted in a rheological blood analogue able to form a CFL, downstream of a microfluidic hyperbolic contraction, in a similar way of the one formed by healthy RBCs.
Collapse
|