1
|
Çimke S, Bayat M. Effect of hand massage after abdominal surgery on pain, emotional symptoms and physiological parameters among children. Pediatr Surg Int 2025; 41:55. [PMID: 39751649 DOI: 10.1007/s00383-024-05954-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/17/2024] [Indexed: 01/04/2025]
Abstract
AIM This randomized controlled study aimed to evaluate the effect of hand massage on pain, emotional symptoms, and physiological parameters in children after abdominal surgery. MATERIALS AND METHODS The study included 40 children aged 7-12 years who underwent abdominal surgery (20 intervention, 20 control). Data were collected using the Faces Pain Scale-Revised, Children's Emotion Manifestation Scale, Physiological Measurements Chart, and Child Information Form. The intervention group received a 10-min hand massage 3 h after surgery, and measurements were taken before the massage, immediately after the massage, and 30 min after the massage. Statistical analyses were performed using the Mann-Whitney U, Friedman, and Bonferroni tests. RESULTS Immediately after the massage, the pain and emotional manifestation scores were significantly lower in the intervention group compared to the control group (p < 0.05). However, no significant difference was found between the two groups at the third measurement (p = 0.478). Heart rate significantly decreased in the intervention group immediately after the massage (p < 0.001), while it significantly increased in the control group (p < 0.001).
Collapse
|
2
|
Efe Arslan D, Kılıç Akça N, Aslan D. The effect of hand massage on fatigue in women with cancer receiving brachytherapy: randomized clinical trial. Support Care Cancer 2024; 33:2. [PMID: 39625640 DOI: 10.1007/s00520-024-09059-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 11/28/2024] [Indexed: 01/03/2025]
Abstract
PURPOSE This randomized controlled study was conducted to analyze the effect of hand massage on the fatigue level of the women receiving brachytherapy. METHODS It was determined that 12 patients were included in each group (control and hand massage group), so 24 women with gynecologic cancer were included in the study. The application was performed on each hand for 5 min, a total of 10 min in hand massage group. Hand massage was applied before each brachytherapy (at the first, second, and third sessions, a total of three times) every other day for 1 week in the hand massage group. No intervention was performed to the control group during the study. The data were collected using the Patient Information Form and Brief Fatigue Inventory (BFI). RESULTS At the end of the brachytherapy, the fatigue severity score and impact of fatigue on activities of daily living scores of the group that applied hand massage were determined to be lower than the control group (p < 0.05). CONCLUSION It was determined that hand massage effectively controlled fatigue and the impact of fatigue on activities of daily living. Hand massage is a safe and economical method that can be performed by certified nurses. TRIAL REGISTRATION This clinical trial is registered at ClinicalTrials.gov (NCT06056713-09/21/2023).
Collapse
Affiliation(s)
- Dilek Efe Arslan
- Halil Bayraktar Health Services Vocational College, Erciyes University, Kayseri, Turkey.
| | - Nazan Kılıç Akça
- Faculty of Health Sciences, University of Bakırçay, İzmir, Turkey
| | - Dicle Aslan
- Department of Radiation Oncology, Faculty of Medicine, Erciyes University, Kayseri, Turkey
| |
Collapse
|
3
|
Wang Q, Pan M, Kreiss L, Samaei S, Carp SA, Johansson JD, Zhang Y, Wu M, Horstmeyer R, Diop M, Li DDU. A comprehensive overview of diffuse correlation spectroscopy: Theoretical framework, recent advances in hardware, analysis, and applications. Neuroimage 2024; 298:120793. [PMID: 39153520 DOI: 10.1016/j.neuroimage.2024.120793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2024] [Revised: 07/23/2024] [Accepted: 08/14/2024] [Indexed: 08/19/2024] Open
Abstract
Diffuse correlation spectroscopy (DCS) is a powerful tool for assessing microvascular hemodynamic in deep tissues. Recent advances in sensors, lasers, and deep learning have further boosted the development of new DCS methods. However, newcomers might feel overwhelmed, not only by the already-complex DCS theoretical framework but also by the broad range of component options and system architectures. To facilitate new entry to this exciting field, we present a comprehensive review of DCS hardware architectures (continuous-wave, frequency-domain, and time-domain) and summarize corresponding theoretical models. Further, we discuss new applications of highly integrated silicon single-photon avalanche diode (SPAD) sensors in DCS, compare SPADs with existing sensors, and review other components (lasers, sensors, and correlators), as well as data analysis tools, including deep learning. Potential applications in medical diagnosis are discussed and an outlook for the future directions is provided, to offer effective guidance to embark on DCS research.
Collapse
Affiliation(s)
- Quan Wang
- Department of Biomedical Engineering, Faculty of Engineering, University of Strathclyde, Glasgow, United Kingdom
| | - Mingliang Pan
- Department of Biomedical Engineering, Faculty of Engineering, University of Strathclyde, Glasgow, United Kingdom
| | - Lucas Kreiss
- Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Saeed Samaei
- Department of Medical and Biophysics, Schulich School of Medical & Dentistry, Western University, London, Ontario, Canada; Lawson Health Research Institute, Imaging Program, London, Ontario, Canada
| | - Stefan A Carp
- Massachusetts General Hospital, Optics at Athinoula A. Martinos Center for Biomedical Imaging, Harvard Medical School, Charlestown, MA, United States
| | | | - Yuanzhe Zhang
- Department of Biomedical Engineering, Faculty of Engineering, University of Strathclyde, Glasgow, United Kingdom
| | - Melissa Wu
- Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Roarke Horstmeyer
- Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Mamadou Diop
- Department of Medical and Biophysics, Schulich School of Medical & Dentistry, Western University, London, Ontario, Canada; Lawson Health Research Institute, Imaging Program, London, Ontario, Canada
| | - David Day-Uei Li
- Department of Biomedical Engineering, Faculty of Engineering, University of Strathclyde, Glasgow, United Kingdom.
| |
Collapse
|
4
|
Gross AR, Lee H, Ezzo J, Chacko N, Gelley G, Forget M, Morien A, Graham N, Santaguida PL, Rice M, Dixon C. Massage for neck pain. Cochrane Database Syst Rev 2024; 2:CD004871. [PMID: 38415786 PMCID: PMC10900303 DOI: 10.1002/14651858.cd004871.pub5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/29/2024]
Abstract
BACKGROUND Massage is widely used for neck pain, but its effectiveness remains unclear. OBJECTIVES To assess the benefits and harms of massage compared to placebo or sham, no treatment or exercise as an adjuvant to the same co-intervention for acute to chronic persisting neck pain in adults with or without radiculopathy, including whiplash-associated disorders and cervicogenic headache. SEARCH METHODS We searched multiple databases (CENTRAL, MEDLINE, EMBASE, CINAHL, Index to Chiropractic Literature, trial registries) to 1 October 2023. SELECTION CRITERIA We included randomised controlled trials (RCTs) comparing any type of massage with sham or placebo, no treatment or wait-list, or massage as an adjuvant treatment, in adults with acute, subacute or chronic neck pain. DATA COLLECTION AND ANALYSIS We used the standard methodological procedures expected by Cochrane. We transformed outcomes to standardise the direction of the effect (a smaller score is better). We used a partially contextualised approach relative to identified thresholds to report the effect size as slight-small, moderate or large-substantive. MAIN RESULTS We included 33 studies (1994 participants analysed). Selection (82%) and detection bias (94%) were common; multiple trials had unclear allocation concealment, utilised a placebo that may not be credible and did not test whether blinding to the placebo was effective. Massage was compared with placebo (n = 10) or no treatment (n = 8), or assessed as an adjuvant to the same co-treatment (n = 15). The trials studied adults aged 18 to 70 years, 70% female, with mean pain severity of 51.8 (standard deviation (SD) 14.1) on a visual analogue scale (0 to 100). Neck pain was subacute-chronic and classified as non-specific neck pain (85%, including n = 1 whiplash), radiculopathy (6%) or cervicogenic headache (9%). Trials were conducted in outpatient settings in Asia (n = 11), America (n = 5), Africa (n = 1), Europe (n = 12) and the Middle East (n = 4). Trials received research funding (15%) from research institutes. We report the main results for the comparison of massage versus placebo. Low-certainty evidence indicates that massage probably results in little to no difference in pain, function-disability and health-related quality of life when compared against a placebo for subacute-chronic neck pain at up to 12 weeks follow-up. It may slightly improve participant-reported treatment success. Subgroup analysis by dose showed a clinically important difference favouring a high dose (≥ 8 sessions over four weeks for ≥ 30 minutes duration). There is very low-certainty evidence for total adverse events. Data on patient satisfaction and serious adverse events were not available. Pain was a mean of 20.55 points with placebo and improved by 3.43 points with massage (95% confidence interval (CI) 8.16 better to 1.29 worse) on a 0 to 100 scale, where a lower score indicates less pain (8 studies, 403 participants; I2 = 39%). We downgraded the evidence to low-certainty due to indirectness; most trials in the placebo comparison used suboptimal massage doses (only single sessions). Selection, performance and detection bias were evident as multiple trials had unclear allocation concealment, utilised a placebo that may not be credible and did not test whether blinding was effective, respectively. Function-disability was a mean of 30.90 points with placebo and improved by 9.69 points with massage (95% CI 17.57 better to 1.81 better) on the Neck Disability Index 0 to 100, where a lower score indicates better function (2 studies, 68 participants; I2 = 0%). We downgraded the evidence to low-certainty due to imprecision (the wide CI represents slight to moderate benefit that does not rule in or rule out a clinically important change) and risk of selection, performance and detection biases. Participant-reported treatment success was a mean of 3.1 points with placebo and improved by 0.80 points with massage (95% CI 1.39 better to 0.21 better) on a Global Improvement 1 to 7 scale, where a lower score indicates very much improved (1 study, 54 participants). We downgraded the evidence to low-certainty due to imprecision (single study with a wide CI that does not rule in or rule out a clinically important change) and risk of performance as well as detection bias. Health-related quality of life was a mean of 43.2 points with placebo and improved by 5.30 points with massage (95% CI 8.24 better to 2.36 better) on the SF-12 (physical) 0 to 100 scale, where 0 indicates the lowest level of health (1 study, 54 participants). We downgraded the evidence once for imprecision (a single small study) and risk of performance and detection bias. We are uncertain whether massage results in increased total adverse events, such as treatment soreness, sweating or low blood pressure (RR 0.99, 95% CI 0.08 to 11.55; 2 studies, 175 participants; I2 = 77%). We downgraded the evidence to very low-certainty due to unexplained inconsistency, risk of performance and detection bias, and imprecision (the CI was extremely wide and the total number of events was very small, i.e < 200 events). AUTHORS' CONCLUSIONS The contribution of massage to the management of neck pain remains uncertain given the predominance of low-certainty evidence in this field. For subacute and chronic neck pain (closest to 12 weeks follow-up), massage may result in a little or no difference in improving pain, function-disability, health-related quality of life and participant-reported treatment success when compared to a placebo. Inadequate reporting on adverse events precluded analysis. Focused planning for larger, adequately dosed, well-designed trials is needed.
Collapse
Affiliation(s)
- Anita R Gross
- Faculty of Health Sciences, School of Rehabilitation Science, McMaster University, Hamilton, ON, Canada
- School of Rehabilitation Science, McMaster University, Hamilton, Canada
| | - Haejung Lee
- Department of Physical Therapy, Silla University, Busan, Korea, South
| | - Jeanette Ezzo
- Research Director, JME Enterprises, Baltimore, Maryland, USA
| | - Nejin Chacko
- Faculty of Health Sciences, School of Rehabilitation Science, McMaster University, Hamilton, ON, Canada
| | - Geoffrey Gelley
- Applied Health Sciences PhD Program, University of Manitoba, Winnipeg, MB, Canada
- Integrative Medicine, University of Manitoba, Winnipeg, Canada
| | - Mario Forget
- Canadian Forces Health Services Group | Groupe de services de santé des Forces Canadiennes, National Defense | Défense Nationale, Kingston, Canada
| | - Annie Morien
- Research Department, Florida School of Massage, Gainesville, FL, USA
| | - Nadine Graham
- Faculty of Health Sciences, School of Rehabilitation Science, McMaster University, Hamilton, ON, Canada
| | - Pasqualina L Santaguida
- Department of Health Research Methods, Evidence, and Impact, McMaster University, Hamilton, ON, Canada
| | | | - Craig Dixon
- Faculty of Health Sciences, School of Rehabilitation Sciences, McMaster University, Hamilton, ON, Canada
| |
Collapse
|
5
|
Gao C, Jia L, Ma M, Zhang X, Li T. Hemodynamic alterations response to Chinese acupuncture therapy monitored by a custom near-infrared spectroscopy probe with an open hole. JOURNAL OF BIOPHOTONICS 2023; 16:e202300124. [PMID: 37264556 DOI: 10.1002/jbio.202300124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2023] [Revised: 05/14/2023] [Accepted: 05/21/2023] [Indexed: 06/03/2023]
Abstract
Traditional acupuncture, a popular traditional Chinese medicine (TCM) technique, has demonstrated potential in relieving various ailments' symptoms. However, its black-box feedback loop model has limited proper evaluation and use by unskilled practitioners. This study aimed to analyze hemodynamic signals around acupoints during acupuncture to identify significant parameter changes. We designed hollow near-infrared spectroscopy (NIRS) probes for real-time measurements during acupuncture at acupoints, monitoring oxy-hemoglobin (HbO), deoxy-hemoglobin (Hb), and blood volume (HbT) changes. Acupuncture was performed on the "Xuehai" acupoint in 17 healthy subjects, with NIRS measuring hemodynamic alterations. Results showed significant and consistent increases in Hb and HbT around the acupoint, returning to baseline values after needle removal. One case of fainting revealed a significant Hb increase and HbO decrease. Acupuncture may induce tissue vasodilation and enhance oxygen consumption. This research provides a potential explanation for acupuncture's mechanism and emphasizes NIRS's potential in TCM.
Collapse
Affiliation(s)
- Chenyang Gao
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China
| | - Lanyu Jia
- Tianjin Academy of Traditional Chinese Medicine Affiliated Hospital, Tianjin, China
| | - Minghua Ma
- Tianjin Academy of Traditional Chinese Medicine Affiliated Hospital, Tianjin, China
| | | | - Ting Li
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China
| |
Collapse
|
6
|
Fogarty S, Werner R, James JL. Applying Scientific Rationale to the Current Perceptions and Explanations of Massage and Miscarriage in the First Trimester. Int J Ther Massage Bodywork 2023; 16:30-43. [PMID: 36866184 PMCID: PMC9949615 DOI: 10.3822/ijtmb.v16i1.771] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2023] Open
Abstract
Miscarriage is a relatively common occurrence, impacting 8-15% of clinically recognised pregnancies, and up to 30% of all conceptions. The public perception of the risk factors associated with miscarriage does not match the evidence. Evidence indicates that there are very few modifiable factors to prevent miscarriage, and the majority of the time little could have been done to prevent a spontaneous miscarriage. However, the public perception is that consuming drugs, lifting a heavy object, previous use of an intrauterine device, or massage can all contribute to miscarriage. While misinformation about the causes and risk factors of miscarriage continues to circulate, pregnant women will experience confusion about what activities they can (and cannot) do in early pregnancy, including receiving a massage. Pregnancy massage is an important component of massage therapy education. The resources that underpin pregnancy massage coursework consist of educational print content that includes direction and caution that massage in the first trimester, if done 'incorrectly' or in the 'wrong' location, can contribute to adverse outcomes such as miscarriage. The most common statements, perceptions and explanations for massage and miscarriage cover three broad areas: 1) maternal changes from massage affects the embryo/fetus; 2) massage leads to damage of the fetus/placenta; and 3) aspects of the massage treatment in the first trimester initiate contractions. The goal of this paper is to use scientific rationale to critically consider the validity of the current perceptions and explanations of massage therapy and miscarriage. Whilst direct evidence from clinical trials was lacking, considerations of physiological mechanisms regulating pregnancy and known risk factors associated with miscarriage provide no evidence that massage in pregnancy would increase a patient's risk of miscarriage. This scientific rationale should be addressed when teaching pregnancy massage courses.
Collapse
Affiliation(s)
- Sarah Fogarty
- Department of Medicine, School of Medicine, Western Sydney University, Sydney, Australia,Corresponding author: Sarah Fogarty, Department of Medicine, School of Medicine, Western Sydney University Campbelltown Campus, Narellan Road & Gilchrist Drive, Campbelltown, NSW 2560, Australia,
| | - Ruth Werner
- Author of A Massage Therapist’s Guide to Pathology, and Board Certified in Therapeutic Massage and Bodywork, USA
| | - Joanna L James
- Department of Obstetrics and Gynaecology, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|
7
|
Matsuda Y, Nakabayashi M, Suzuki T, Zhang S, Ichinose M, Ono Y. Evaluation of Local Skeletal Muscle Blood Flow in Manipulative Therapy by Diffuse Correlation Spectroscopy. Front Bioeng Biotechnol 2022; 9:800051. [PMID: 35087803 PMCID: PMC8786806 DOI: 10.3389/fbioe.2021.800051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 12/17/2021] [Indexed: 11/13/2022] Open
Abstract
Manipulative therapy (MT) is applied to motor organs through a therapist’s hands. Although MT has been utilized in various medical treatments based on its potential role for increasing the blood flow to the local muscle, a quantitative validation of local muscle blood flow in MT remains challenging due to the lack of appropriate bedside evaluation techniques. Therefore, we investigated changes in the local blood flow to the muscle undergoing MT by employing diffuse correlation spectroscopy, a portable and emerging optical measurement technology that non-invasively measures blood flow in deep tissues. This study investigated the changes in blood flow, heart rate, blood pressure, and autonomic nervous activity in the trapezius muscle through MT application in 30 volunteers without neck and shoulder injury. Five minutes of MT significantly increased the median local blood flow relative to that of the pre-MT period (p < 0.05). The post-MT local blood flow increase was significantly higher in the MT condition than in the control condition, where participants remained still without receiving MT for the same time (p < 0.05). However, MT did not affect the heart rate, blood pressure, or cardiac autonomic nervous activity. The post-MT increase in muscle blood flow was significantly higher in the participants with muscle stiffness in the neck and shoulder regions than in those without (p < 0.05). These results suggest that MT could increase the local blood flow to the target skeletal muscle, with minimal effects on systemic circulatory function.
Collapse
Affiliation(s)
- Yasuhiro Matsuda
- Electrical Engineering Program, Graduate School of Science and Technology, Meiji University, Kawasaki, Japan
- Faculty of Medical Science, Nippon Sport Science University, Yokohama, Japan
| | - Mikie Nakabayashi
- Electrical Engineering Program, Graduate School of Science and Technology, Meiji University, Kawasaki, Japan
- Japan Society for the Promotion of Science (JSPS), Tokyo, Japan
| | - Tatsuya Suzuki
- Electrical Engineering Program, Graduate School of Science and Technology, Meiji University, Kawasaki, Japan
| | - Sinan Zhang
- Electrical Engineering Program, Graduate School of Science and Technology, Meiji University, Kawasaki, Japan
- Department of Electronics and Bioinformatics, School of Science and Technology, Meiji University, Kawasaki, Japan
| | - Masashi Ichinose
- Human Integrative Physiology Laboratory, School of Business Administration, Meiji University, Tokyo, Japan
| | - Yumie Ono
- Department of Electronics and Bioinformatics, School of Science and Technology, Meiji University, Kawasaki, Japan
- *Correspondence: Yumie Ono,
| |
Collapse
|
8
|
Erzincanli S, Kasar KS. Effect of Hand Massage on Pain, Anxiety, and Vital Signs in Patients Before Venipuncture Procedure: A Randomized Controlled Trial. Pain Manag Nurs 2021; 22:356-360. [PMID: 33472757 DOI: 10.1016/j.pmn.2020.12.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 12/05/2020] [Accepted: 12/08/2020] [Indexed: 11/16/2022]
Abstract
BACKGROUND Massage is one of the relaxation techniques commonly used in recent years to control pain, stress, and anxiety. AIMS This study was conducted to evaluate the effect of hand massage application on pain, anxiety, and vital signs before venipuncture procedure. METHODS The sample of the study consisted of 97 individuals (48 experimental and 49 controls) who were admitted to a training and research hospital in Turkey between December 2018 and May 2019. Individuals assigned to the experimental group received hand massage. The data were obtained with an individual information form, a visual analog scale (VAS), and the State-Trait Anxiety Inventory (STAI). RESULTS The mean age of the participants was 49.52 ± 12.48 years. There was no significant difference between the pain levels of the experimental and control groups (p > .05), but the anxiety level of the experimental group was significantly less than that of the control group (p < .05). There was also a significant difference between the experimental and control groups in terms of systolic and diastolic blood pressure and heart rate. The blood pressure and heart rate of the experimental group decreased significantly (p < .05). CONCLUSION Hand massage was found to be a simple, non-pharmacologic, inexpensive, and independent nursing practice that could be used to reduce anxiety and positively affect vital signs in patients before venipuncture procedure.
Collapse
Affiliation(s)
- Saadet Erzincanli
- Department of Nursing, Faculty of Health Sciences, Aksaray University, Aksaray, Turkey.
| | - Kadriye Sayin Kasar
- Department of Nursing, Faculty of Health Sciences, Aksaray University, Aksaray, Turkey
| |
Collapse
|
9
|
Gao C, Li T. Online Assessment of Hemodynamics in the Suctioned Volume of Biological Tissue by an Embedded Near-Infrared Spectroscopy Sensor. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1269:71-75. [PMID: 33966197 DOI: 10.1007/978-3-030-48238-1_11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Cupping therapy is a promising method to cure or reduce symptoms of some diseases including muscle pain/tenderness/fatigue. Although the applications of cupping therapy have a thousand-year history in traditional Chinese medicine and have been spread to other countries in recent years, cupping therapy is something like a black box, and the unskilled user can hardly control it due to the absence of physiological observations. In this study, we developed a NIRS instrument with three probes to detect the blood-oxygen level of the skin tissue where the cupping therapy is being carried out. Each probe includes two detection channels. One of the probes is embedded in the cup to monitor the hemodynamic parameters in the cupping site, and the other two probes are placed outside, surrounding the cupping site. Using this monitor, we can observe the changes in oxy-hemoglobin ([HbO2]), deoxy-hemoglobin ([Hb]), and total hemoglobin ([tHb]), as well as the heart rate, calculated from the change curves of [HbO2] during cupping therapy in real time. Therefore, the doctor or other users can see the impact of cupping on the tissues to which it is applied which should facilitate the development and understanding of the application of cupping.
Collapse
Affiliation(s)
- Chenyang Gao
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, P. R. China
| | - Ting Li
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, P. R. China.
| |
Collapse
|
10
|
Carroll K, Yiu EM, Ryan MM, Kennedy RA, de Valle K. The effects of calf massage in boys with Duchenne muscular dystrophy: a prospective interventional study. Disabil Rehabil 2020; 43:3803-3809. [PMID: 32356505 DOI: 10.1080/09638288.2020.1753829] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Purpose: We explored the effects of standardized calf massage in ambulant boys with Duchenne muscular dystrophy (DMD) using a prospective study design.Materials and Methods: Twenty boys completed two study visits, 1 week apart. At both visits, each leg received a 10-min calf massage (intervention) and a 10-min control rest period (placebo) in randomized order. Muscle length of calf and hamstrings and gastrocnemius stiffness were measured by a blinded assessor before and after intervention and placebo. Measures of gait function (timed 10-m walk/run and spatio-temporal gait parameters); gastrocnemius muscle ultrasound findings; participant perception of leg pain, stiffness and effort of walking and general psychological well-being were also collected.Results: Consistent significant small increases in muscle length of soleus, gastrocnemius and hamstrings were recorded post-massage, and gastrocnemius stiffness decreased. Small changes in gastrocnemius and soleus length only were also recorded following the control rest period. Gait function and general well-being remained stable throughout. Measurement across both study visits suggested that gains in muscle length may be cumulative with repeated massage.Conclusions: Calf massage is safe and associated with benefits to muscle length and stiffness for ambulant boys with DMD.Implications for RehabilitationIn a small sample of boys with Duchenne muscular dystrophy, calf massage was found to be safe, well-tolerated and associated with increased muscle length and decreased stiffness.The use of massage may assist in managing muscle length in boys with Duchenne muscular dystrophy.
Collapse
Affiliation(s)
- Kate Carroll
- Department of Neurology, The Royal Children's Hospital, Melbourne, VIC, Australia.,Murdoch Children's Research Institute, Melbourne, VIC, Australia.,Department of Physiotherapy, The University of Melbourne, Melbourne, VIC, Australia
| | - Eppie M Yiu
- Department of Neurology, The Royal Children's Hospital, Melbourne, VIC, Australia.,Murdoch Children's Research Institute, Melbourne, VIC, Australia.,Department of Paediatrics, The University of Melbourne, Melbourne, VIC, Australia
| | - Monique M Ryan
- Department of Neurology, The Royal Children's Hospital, Melbourne, VIC, Australia.,Murdoch Children's Research Institute, Melbourne, VIC, Australia.,Department of Paediatrics, The University of Melbourne, Melbourne, VIC, Australia
| | - Rachel A Kennedy
- Department of Neurology, The Royal Children's Hospital, Melbourne, VIC, Australia.,Murdoch Children's Research Institute, Melbourne, VIC, Australia
| | - Katy de Valle
- Department of Neurology, The Royal Children's Hospital, Melbourne, VIC, Australia.,Murdoch Children's Research Institute, Melbourne, VIC, Australia
| |
Collapse
|
11
|
Yücel ŞÇ, Arslan GG, Bagci H. Effects of Hand Massage and Therapeutic Touch on Comfort and Anxiety Living in a Nursing Home in Turkey: A Randomized Controlled Trial. JOURNAL OF RELIGION AND HEALTH 2020; 59:351-364. [PMID: 30982141 DOI: 10.1007/s10943-019-00813-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
This study was carried out to investigate the effects of hand massage and therapeutic touch on comfort and anxiety in the elderly living in nursing homes. The study was designed as a randomized controlled, experimental study (with a pre- and posttest control group). The study population comprised 255 older people aged 65-89 living in a nursing home in Izmir, a province in Turkey. The study sample included 30 older patients, who were assigned to hand massage (HM) (n = 10), therapeutic touch (TT) (n = 10) and control (C) (n = 10) groups. Of the elderly who participated in the study, 50% were female and 80% were single. It was determined that TT and HM decreased the anxiety and increased the comfort levels of the elderly living in the nursing home (p < 0.05). It is thought that nurses can easily integrate HM and TT which are non-medical, non-pharmacologic interventions with no adverse effects into care activities.
Collapse
Affiliation(s)
- Şebnem Çınar Yücel
- Department of Fundamentals Nursing, Ege University Nursing School, 35000, Izmir, Turkey
| | - Gamze Goke Arslan
- Department of Fundamentals Nursing, Faculty of Health Sciences, Karamanoglu Mehmetbey University, 70000, Karaman, Turkey.
| | - Hazel Bagci
- Department of Fundamentals Nursing, Ege University Nursing School, 35000, Izmir, Turkey
| |
Collapse
|
12
|
Gao C, Wang M, He L, He Y, Li T. Alternations of hemodynamic parameters during Chinese cupping therapy assessed by an embedded near-infrared spectroscopy monitor. BIOMEDICAL OPTICS EXPRESS 2019; 10:196-203. [PMID: 30775093 PMCID: PMC6363192 DOI: 10.1364/boe.10.000196] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Revised: 11/01/2018] [Accepted: 12/04/2018] [Indexed: 05/07/2023]
Abstract
Cupping therapy is a promising method to cure or reduce the symptoms of some diseases including muscle pain/tendency/fatigue. Although the applications of cupping therapy have a thousand-year history in traditional Chinese medicine, the therapeutic effect of cupping is still questionable due to a lack of scientific evidence and the absence of physiological observations. In our previous study, we utilized near-infrared spectroscopy (NIRS) to assess the concentration change surrounding the cupping site and found a significant elevation in oxy-hemoglobin (HbO2). To further investigate the therapeutic effect of dry cupping treatment, we embedded a NIRS sensor into a suction cup to monitor the hemodynamic changes including HbO2, deoxy-hemoglobin ([Hb]) and blood volume on the cupping site in this study. Both a prominent elevation in [Hb] and a significant drop in [HbO2] in the tissue of the cupping site were observed during cupping. We also observed similar hemodynamic changes during post-cupping, which may demonstrate how cupping therapy works for treatment. This study showed that the embedding of NIRS sensor in a cupping system could offer a better understanding of the mechanism of cupping therapy.
Collapse
Affiliation(s)
- Chenyang Gao
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300000, China
| | - Meng Wang
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300000, China
| | - Ling He
- Rehabilitation Department of Traditional Chinese Medicine of UESTC Hospital, Chengdu 610000, China
| | - Yanni He
- Rehabilitation Department of Traditional Chinese Medicine of UESTC Hospital, Chengdu 610000, China
| | - Ting Li
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300000, China
| |
Collapse
|
13
|
Larson ER, Kinkead B, Edwards SA, Schettler PJ, Dunlop BW, Rakofsky JJ, Rapaport MH. Model structure for protocol adherence utilizing a manualized therapeutic massage intervention. JOURNAL OF COMPLEMENTARY & INTEGRATIVE MEDICINE 2018; 16:/j/jcim.2019.16.issue-2/jcim-2016-0118/jcim-2016-0118.xml. [PMID: 30312159 PMCID: PMC11748186 DOI: 10.1515/jcim-2016-0118] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Accepted: 07/12/2018] [Indexed: 01/23/2025]
Abstract
Background The Protocol Training and Assessment Model (Model) was developed through collaboration between Emory University School of Medicine and Atlanta School of Massage to minimize intra- and inter-therapist variability for two research massage therapist (rMT) applied intervention arms in the Massage for Cancer-Related Fatigue (MCRF) early-phase study. The Model was followed to maintain and assess protocol integrity for the study's manualized Swedish massage therapy (SMT) and light touch (LT) interventions. Methods The Model includes initial rMT training, quarterly retraining sessions, accessible resources (scripts, treatment guides, weekly research personnel meetings), and ongoing monitoring. Model efficacy was assessed by monitoring data collected at retraining sessions, through audio recording review, and through subject and rMT reporting. Results Model application resulted in a high level of intervention consistency throughout the study. Protocol-related session comment rate by subjects was 2.7%. Few study participants reported intra-rMT or inter-rMT treatment delivery differences. Observation during retraining sessions indicated massage therapists continued to adhere to protocols. Importantly rMTs increased their participation beyond core duties, suggesting additional ways to standardize subject treatment experience. Conclusions Through systematic application of the Protocol Training and Assessment Model, continuous and collaborative quality improvement discussions between scientists and research massage therapists resulted in reliable, standardized SMT and LT interventions for the MCRF early-phase study. Future research can apply the Model to support and assess consistent rMT-delivered intervention applications.
Collapse
Affiliation(s)
| | - Becky Kinkead
- Department of Psychiatry and Behavioral Sciences, Emory University School of Medicine, Atlanta, GA, USA
| | - Sherry A. Edwards
- Department of Psychiatry and Behavioral Sciences, Emory University School of Medicine, Atlanta, GA, USA
| | - Pamela J. Schettler
- Department of Psychiatry and Behavioral Sciences, Emory University School of Medicine, Atlanta, GA, USA
- Depatrtment of Psychiatry, University of California San Diego School of Medicine, San Diego, CA, USA
| | - Boadie W. Dunlop
- Department of Psychiatry and Behavioral Sciences, Emory University School of Medicine, Atlanta, GA, USA
| | - Jeffrey J. Rakofsky
- Department of Psychiatry and Behavioral Sciences, Emory University School of Medicine, Atlanta, GA, USA
| | - Mark H. Rapaport
- Department of Psychiatry and Behavioral Sciences, Emory University School of Medicine, Atlanta, GA, USA
| |
Collapse
|
14
|
Bangalore-Yogananda CG, Rosenberry R, Soni S, Liu H, Nelson MD, Tian F. Concurrent measurement of skeletal muscle blood flow during exercise with diffuse correlation spectroscopy and Doppler ultrasound. BIOMEDICAL OPTICS EXPRESS 2018; 9:131-141. [PMID: 29359092 PMCID: PMC5772569 DOI: 10.1364/boe.9.000131] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Revised: 11/26/2017] [Accepted: 12/05/2017] [Indexed: 06/01/2023]
Abstract
Noninvasive, direct measurement of local muscle blood flow in humans remains limited. Diffuse correlation spectroscopy (DCS) is an emerging technique to measure regional blood flow at the microvascular level. In order to better understand the strengths and limitations of this novel technique, we performed a validation study by comparing muscle blood flow changes measured with DCS and Doppler ultrasound during exercise. Nine subjects were measured (all males, 27.4 ± 2.9 years of age) for a rhythmic handgrip exercise at 20% and 50% of individual maximum voluntary contraction (MVC), followed by a post-exercise recovery. The results from DCS and Doppler ultrasound were highly correlated (R = 0.99 ± 0.02). DCS was more reliable and less susceptible to motion artifact.
Collapse
Affiliation(s)
- Chandan-Ganesh Bangalore-Yogananda
- Department of Bioengineering, The University of Texas at Arlington, 500 UTA Blvd., Arlington, TX 76010, USA
- Two authors contributed equally
| | - Ryan Rosenberry
- Department of Kinesiology, The University of Texas at Arlington, 411 S. Nedderman Dr., Arlington, TX 76010, USA
- Two authors contributed equally
| | - Sagar Soni
- Department of Bioengineering, The University of Texas at Arlington, 500 UTA Blvd., Arlington, TX 76010, USA
| | - Hanli Liu
- Department of Bioengineering, The University of Texas at Arlington, 500 UTA Blvd., Arlington, TX 76010, USA
| | - Michael D. Nelson
- Department of Bioengineering, The University of Texas at Arlington, 500 UTA Blvd., Arlington, TX 76010, USA
- Department of Kinesiology, The University of Texas at Arlington, 411 S. Nedderman Dr., Arlington, TX 76010, USA
| | - Fenghua Tian
- Department of Bioengineering, The University of Texas at Arlington, 500 UTA Blvd., Arlington, TX 76010, USA
| |
Collapse
|
15
|
Shah Y, Arkesteijn M, Thomas D, Whyman J, Passfield L. The acute effects of integrated myofascial techniques on lumbar paraspinal blood flow compared with kinesio-taping: A pilot study. J Bodyw Mov Ther 2017; 21:459-467. [DOI: 10.1016/j.jbmt.2016.08.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2016] [Revised: 07/09/2016] [Accepted: 08/24/2016] [Indexed: 11/26/2022]
|
16
|
Shang Y, Li T, Yu G. Clinical applications of near-infrared diffuse correlation spectroscopy and tomography for tissue blood flow monitoring and imaging. Physiol Meas 2017; 38:R1-R26. [PMID: 28199219 PMCID: PMC5726862 DOI: 10.1088/1361-6579/aa60b7] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVE Blood flow is one such available observable promoting a wealth of physiological insight both individually and in combination with other metrics. APPROACH Near-infrared diffuse correlation spectroscopy (DCS) and, to a lesser extent, diffuse correlation tomography (DCT), have increasingly received interest over the past decade as noninvasive methods for tissue blood flow measurements and imaging. DCS/DCT offers several attractive features for tissue blood flow measurements/imaging such as noninvasiveness, portability, high temporal resolution, and relatively large penetration depth (up to several centimeters). MAIN RESULTS This review first introduces the basic principle and instrumentation of DCS/DCT, followed by presenting clinical application examples of DCS/DCT for the diagnosis and therapeutic monitoring of diseases in a variety of organs/tissues including brain, skeletal muscle, and tumor. SIGNIFICANCE Clinical study results demonstrate technical versatility of DCS/DCT in providing important information for disease diagnosis and intervention monitoring.
Collapse
Affiliation(s)
- Yu Shang
- Key Laboratory of Instrumentation Science & Dynamic Measurement, North University of China, No.3 Xueyuan Road, Taiyuan, Shanxi 030051, China
| | - Ting Li
- State Key Lab Elect Thin Film & Integrated Device, University of Electronic Science & Technology of China, Chengdu, Sichuan 610054, China
| | - Guoqiang Yu
- Department of Biomedical Engineering, University of Kentucky, 514C RMB, 143 Graham Avenue, Lexington, KY 40506-0108, USA
| |
Collapse
|
17
|
Li T, Li Y, Lin Y, Li K. Significant and sustaining elevation of blood oxygen induced by Chinese cupping therapy as assessed by near-infrared spectroscopy. BIOMEDICAL OPTICS EXPRESS 2017; 8:223-229. [PMID: 28101413 PMCID: PMC5231294 DOI: 10.1364/boe.8.000223] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Revised: 11/11/2016] [Accepted: 12/05/2016] [Indexed: 05/07/2023]
Abstract
Cupping therapy has been used in traditional Chinese medicine for thousands of years to relieve muscle pain/tendency/fatigue and to cure or reduce symbols of other diseases. However, its therapeutic effect is sparsely interpreted in the language of modern physiology. To objectively evaluate its therapeutic effect, we focused on dry cupping treatment and utilized near-infrared spectroscopy (NIRS) to assess the concentration change in oxy-hemoglobin ([HbO2]), deoxy-hemoglobin ([Hb]), and blood volume in the course of cupping therapy over 13 volunteers on the infraspinatus muscle, where is usually applied for shoulder pains. Both a prominent drop in [Hb] and a significant elevation in [HbO2] in the tissue surrounding the cupping site were observed during both cupping and post-treatment, manifesting the enhancement of oxygen uptake. This resulting promotion indicates potential positive therapeutic effect of cupping therapy in hemodynamics for facilitating muscular functions.
Collapse
Affiliation(s)
- Ting Li
- State Key Lab Elect Thin Film & Integrated Device, University of Electronic Science & Technology of China, Chengdu 610054, China
- Shenzhen Geno-Immune Medicine Institute, Shenzhen, China
| | - Yaoxian Li
- State Key Lab Elect Thin Film & Integrated Device, University of Electronic Science & Technology of China, Chengdu 610054, China
| | - Yu Lin
- North Carolina State University, Raleigh, NC 27695, USA
| | - Kai Li
- State Key Lab Elect Thin Film & Integrated Device, University of Electronic Science & Technology of China, Chengdu 610054, China
| |
Collapse
|
18
|
Wistbacka G, Sundberg J, Simberg S. Vertical laryngeal position and oral pressure variations during resonance tube phonation in water and in air. A pilot study. LOGOP PHONIATR VOCO 2015; 41:117-23. [DOI: 10.3109/14015439.2015.1028101] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Affiliation(s)
- Greta Wistbacka
- Faculty of Arts, Psychology and Theology, Åbo Akademi University, Turku, Finland
| | - Johan Sundberg
- Dept. of Speech Music Hearing, School of Computer Science and Communication, KTH (Royal Institute of Technology) Stockholm, Sweden
- College of Music Education, Stockholm, Sweden
| | - Susanna Simberg
- Faculty of Arts, Psychology and Theology, Åbo Akademi University, Turku, Finland
| |
Collapse
|
19
|
Peripheral conduit and resistance artery function are improved following a single, 1-h bout of peristaltic pulse external pneumatic compression. Eur J Appl Physiol 2015; 115:2019-29. [PMID: 25981709 DOI: 10.1007/s00421-015-3187-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2015] [Accepted: 05/08/2015] [Indexed: 10/23/2022]
Abstract
INTRODUCTION External pneumatic compression (EPC) is being employed for a widening range of clinical and non-clinical populations. However, EPC devices vary markedly in treatment pressures, duty cycles and application sites, and the acute effects of whole limb, lower pressure EPC on peripheral vascular function have not been determined. PURPOSE The purpose of this study was to determine the acute effects of a single bout of peristaltic pulse EPC on peripheral conduit and resistance artery function. METHODS Twenty (n = 20; males = 12 and females = 8) young and apparently healthy subjects (aged 26.1 ± 8.2 years) participated in this study. A sequential EPC device with five inflation zones arranged linearly and inflating distal to proximal along the lower limbs was employed with target inflation pressures of 70 mmHg for 1 h. Flow-mediated dilation (FMD) of the brachial and popliteal arteries was evaluated with ultrasound before and after EPC. Venous occlusion plethysmography was employed to evaluate limb blood flow at rest and during reactive hyperemia (RH) in the forearm (FBF) and calf (CBF) before and after EPC. RESULTS Peak RH CBF was increased by 9 % after EPC (P < 0.05), whereas peak RH FBF (-10 %) did not change significantly (P > 0.25). Normalized popliteal artery FMD post-EPC (2.24 ± 1.41) was significantly higher than pre-EPC (1.36 ± 0.67, P = 0.015) and post-sham (1.58 ± 0.86, P = 0.032) values. Similarly, normalized brachial artery FMD post-EPC (1.47 ± 0.32) was significantly higher than pre-EPC (1.11 ± 0.41, P = 0.004) and post-sham (0.99 ± 0.27, P = 0.026) values. CONCLUSION Acutely, whole limb, lower pressure EPC improves conduit artery endothelial function systemically, but only improves RH blood flow locally (i.e., compressed limbs).
Collapse
|
20
|
Evaluation of a textile-based near infrared spectroscopy system in calf muscle oxygenation measurements. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2014. [PMID: 24729254 DOI: 10.1007/978-1-4939-0620-8_47] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register]
Abstract
We recently introduced a novel textile-based NIRS sensor (TexNIRS). Here, we evaluate TexNIRS in ten subjects (16 legs, age 28.5 ± 2.32 years, adipose tissue thickness (ATT) 4.17 ± 1.71 mm). Three venous occlusions at 50 mmHg were performed on their calf muscle. After 3 min of occlusion, oxy/deoxy hemoglobin concentration ([O₂Hb], [HHb]) changes were 3.71 ± 1.89/1.79 ± 1.08 μM; venous oxygen saturation (SvO₂) was 75 ± 9.7 %, oxygen consumption (VO₂) was 0.02 ± 0.01 mL/100 g/min, hemoglobin flow (HF) was 0.93 ± 0.48 μmol/100 mL/min, and blood flow (BF) was 2.01 ± 1.04 mL/100 mL/min. Our results are in good agreement with the literature, but the TexNIRS enables a much higher level of comfort.
Collapse
|
21
|
Cino K. Aromatherapy hand massage for older adults with chronic pain living in long-term care. J Holist Nurs 2014; 32:304-13; quiz 314-5. [PMID: 24733781 DOI: 10.1177/0898010114528378] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE Older adults living in long-term care experience high rates of chronic pain. Concerns with pharmacologic management have spurred alternative approaches. The purpose of this study was to examine a nursing intervention for older adults with chronic pain. DESIGN This prospective, randomized control trial compared the effect of aromatherapy M technique hand massage, M technique without aromatherapy, and nurse presence on chronic pain. Chronic pain was measured with the Geriatric Multidimensional Pain and Illness Inventory factors, pain and suffering, life interference, and emotional distress and the Iowa Pain Thermometer, a pain intensity scale. METHOD Three groups of 39 to 40 participants recruited from seven long-term care facilities participated twice weekly for 4 weeks. Analysis included multivariate analysis of variance and analysis of variance. FINDINGS Participants experienced decreased levels of chronic pain intensity. Group membership had a significant effect on the Geriatric Multidimensional Pain Inventory Pain and Suffering scores; Iowa Pain Thermometer scores differed significantly within groups. CONCLUSIONS M technique hand massage with or without aromatherapy significantly decreased chronic pain intensity compared to nurse presence visits. M technique hand massage is a safe, simple, but effective intervention. Caregivers using it could improve chronic pain management in this population.
Collapse
Affiliation(s)
- Kathleen Cino
- Farmingdale State College, State University of New York
| |
Collapse
|
22
|
Cheng R, Zhang X, Daugherty A, Shin H, Yu G. Noninvasive quantification of postocclusive reactive hyperemia in mouse thigh muscle by near-infrared diffuse correlation spectroscopy. APPLIED OPTICS 2013; 52:7324-30. [PMID: 24216586 DOI: 10.1364/ao.52.007324] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Many vasculature-related diseases affecting skeletal muscle function have been studied in mouse models. Noninvasive quantification of muscle blood flow responses during postocclusive reactive hyperemia (PORH) is often used to evaluate vascular function in human skeletal muscles. However, blood flow measurements during PORH in small skeletal muscles of mice are rare due to the lack of appropriate technologies coupled with the challenge of measurement setup resulting from the lack of large enough test sites. In this study, we explored adapting diffuse correlation spectroscopy (DCS) for noninvasive measurement of the relative changes of blood flow (rBF) in mouse thigh muscles during PORH. A small fiber-optic probe was designed and glued on the mouse thigh to reduce the motion artifact induced by the occlusion procedure. Arterial occlusion was created by tying a polyvinyl chloride (PVC) tube around the mouse thigh while the muscle rBF was continuously monitored by DCS to ensure the success of the occlusion. After 5 min, the occlusion was rapidly released by severing the PVC tube using a cautery pen. Typical rBF responses during PORH were observed in all mice (n=7), which are consistent with those observed by arterial-spin-labeled magnetic resonance imaging (ASL-MRI) as reported in the literature. On average, rBF values from DCS during occlusion were lower than 10% (3.1±2.2%) of the baseline values (assigning 100%), indicating the success of arterial occlusion in all mice. Peak values of rBF during PORH measured by the DCS (357.6±36.3%) and ASL-MRI (387.5±150.0%) were also similar whereas the values of time-to-peak (the time duration from the end of occlusion to the peak rBF) were quite different (112.6±35.0 s versus 48.0±27.0 s). Simultaneous measurements by these two techniques are needed to identify the factors that may cause such discrepancy. This study highlights the utility of DCS technology to quantitatively evaluate tissue blood flow responses during PORH in mouse skeletal muscles. DCS holds promise as valuable tool to assess blood flow regulation in mouse models with a variety of vascular diseases (e.g., hypercholesterolemia, diabetes, peripheral artery disease).
Collapse
|
23
|
Shang Y, Lin Y, Henry BA, Cheng R, Huang C, Chen L, Shelton BJ, Swartz KR, Salles SS, Yu G. Noninvasive evaluation of electrical stimulation impacts on muscle hemodynamics via integrating diffuse optical spectroscopies with muscle stimulator. JOURNAL OF BIOMEDICAL OPTICS 2013; 18:105002. [PMID: 24096298 PMCID: PMC3790391 DOI: 10.1117/1.jbo.18.10.105002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2013] [Accepted: 09/04/2013] [Indexed: 05/03/2023]
Abstract
Technologies currently available for the monitoring of electrical stimulation (ES) in promoting blood circulation and tissue oxygenation are limited. This study integrated a muscle stimulator with a diffuse correlation spectroscopy (DCS) flow-oximeter to noninvasively quantify muscle blood flow and oxygenation responses during ES. Ten healthy subjects were tested using the integrated system. The muscle stimulator delivered biphasic electrical current to right leg quadriceps muscle, and a custom-made DCS flow-oximeter was used for simultaneous measurements of muscle blood flow and oxygenation in both legs. To minimize motion artifact of muscle fibers during ES, a novel gating algorithm was developed for data acquisition at the time when the muscle was relaxed. ES at 2, 10, and 50 Hz were applied for 20 min on each subject in three days sequentially. Results demonstrate that the 20-min ES at all frequencies promoted muscle blood flow significantly. However, only the ES at 10 Hz resulted in significant and persistent increases in oxy-hemoglobin concentration during and post ES. This pilot study supports the application of the integrated system to quantify tissue hemodynamic improvements for the optimization of ES treatment in patients suffering from diseases caused by poor blood circulation and low tissue oxygenation (e.g., pressure ulcer).
Collapse
Affiliation(s)
- Yu Shang
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky 40506
| | - Yu Lin
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky 40506
| | - Brad A. Henry
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky 40506
| | - Ran Cheng
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky 40506
| | - Chong Huang
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky 40506
| | - Li Chen
- University of Kentucky, Department of Biostatistics, Lexington, Kentucky 40536
| | - Brent J. Shelton
- University of Kentucky, Department of Biostatistics, Lexington, Kentucky 40536
| | - Karin R. Swartz
- University of Kentucky, Department of Neurosurgery, Lexington, Kentucky 40536
| | - Sara S. Salles
- University of Kentucky, Department of Physical Medicine and Rehabilitation, Lexington, Kentucky 40536
| | - Guoqiang Yu
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky 40506
- Address all correspondence to: Guoqiang Yu, University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky 40506. Tel: 859-257-9110; Fax: 859-257-1856; E-mail:
| |
Collapse
|
24
|
He L, Lin Y, Shang Y, Shelton BJ, Yu G. Using optical fibers with different modes to improve the signal-to-noise ratio of diffuse correlation spectroscopy flow-oximeter measurements. JOURNAL OF BIOMEDICAL OPTICS 2013; 18:037001. [PMID: 23455963 PMCID: PMC4023649 DOI: 10.1117/1.jbo.18.3.037001] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The dual-wavelength diffuse correlation spectroscopy (DCS) flow-oximeter is an emerging technique enabling simultaneous measurements of blood flow and blood oxygenation changes in deep tissues. High signal-to-noise ratio (SNR) is crucial when applying DCS technologies in the study of human tissues where the detected signals are usually very weak. In this study, single-mode, few-mode, and multimode fibers are compared to explore the possibility of improving the SNR of DCS flow-oximeter measurements. Experiments on liquid phantom solutions and in vivo muscle tissues show only slight improvements in flow measurements when using the few-mode fiber compared with using the single-mode fiber. However, light intensities detected by the few-mode and multimode fibers are increased, leading to significant SNR improvements in detections of phantom optical property and tissue blood oxygenation. The outcomes from this study provide useful guidance for the selection of optical fibers to improve DCS flow-oximeter measurements.
Collapse
Affiliation(s)
- Lian He
- University of Kentucky, Center for Biomedical Engineering, Lexington, Kentucky 40506
| | - Yu Lin
- University of Kentucky, Center for Biomedical Engineering, Lexington, Kentucky 40506
| | - Yu Shang
- University of Kentucky, Center for Biomedical Engineering, Lexington, Kentucky 40506
| | - Brent J. Shelton
- University of Kentucky, Markey Cancer Center, Lexington, Kentucky 40536
| | - Guoqiang Yu
- University of Kentucky, Center for Biomedical Engineering, Lexington, Kentucky 40506
- Address all correspondence to: Guoqiang Yu, University of Kentucky, Center for Biomedical Engineering, Lexington, Kentucky 40506. Tel: 859-257-9110; Fax: 859-257-1856; E-mail:
| |
Collapse
|
25
|
Shang Y, Gurley K, Yu G. Diffuse Correlation Spectroscopy (DCS) for Assessment of Tissue Blood Flow in Skeletal Muscle: Recent Progress. ACTA ACUST UNITED AC 2013; 3:128. [PMID: 24724043 PMCID: PMC3979478 DOI: 10.4172/2161-0940.1000128] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Near-infrared diffuse correlation spectroscopy (DCS) is an emerging technology for monitoring blood flow in various tissues. This article reviews the recent progress of DCS for the assessment of skeletal muscle blood flow, including the developments in technology allowing use during dynamic exercise and muscular electrical stimulation, the utilization for diagnosis of muscle vascular diseases, and the applications for evaluating treatment effects. The limitations of current DCS studies and future perspective are finally discussed.
Collapse
Affiliation(s)
- Yu Shang
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Katelyn Gurley
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA ; Department of Neurological Surgery, University of Louisville, Louisville, KY 40202, USA
| | - Guoqiang Yu
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| |
Collapse
|
26
|
Shang Y, Gurley K, Symons B, Long D, Srikuea R, Crofford LJ, Peterson CA, Yu G. Noninvasive optical characterization of muscle blood flow, oxygenation, and metabolism in women with fibromyalgia. Arthritis Res Ther 2012; 14:R236. [PMID: 23116302 PMCID: PMC3674608 DOI: 10.1186/ar4079] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2012] [Accepted: 10/25/2012] [Indexed: 12/11/2022] Open
Abstract
Introduction Women with fibromyalgia (FM) have symptoms of increased muscular fatigue and reduced exercise tolerance, which may be associated with alterations in muscle microcirculation and oxygen metabolism. This study used near-infrared diffuse optical spectroscopies to noninvasively evaluate muscle blood flow, blood oxygenation and oxygen metabolism during leg fatiguing exercise and during arm arterial cuff occlusion in post-menopausal women with and without FM. Methods Fourteen women with FM and twenty-three well-matched healthy controls participated in this study. For the fatiguing exercise protocol, the subject was instructed to perform 6 sets of 12 isometric contractions of knee extensor muscles with intensity steadily increasing from 20 to 70% maximal voluntary isometric contraction (MVIC). For the cuff occlusion protocol, forearm arterial blood flow was occluded via a tourniquet on the upper arm for 3 minutes. Leg or arm muscle hemodynamics, including relative blood flow (rBF), oxy- and deoxy-hemoglobin concentration ([HbO2] and [Hb]), total hemoglobin concentration (THC) and blood oxygen saturation (StO2), were continuously monitored throughout protocols using a custom-built hybrid diffuse optical instrument that combined a commercial near-infrared oximeter for tissue oxygenation measurements and a custom-designed diffuse correlation spectroscopy (DCS) flowmeter for tissue blood flow measurements. Relative oxygen extraction fraction (rOEF) and oxygen consumption rate (rVO2) were calculated from the measured blood flow and oxygenation data. Post-manipulation (fatiguing exercise or cuff occlusion) recovery in muscle hemodynamics was characterized by the recovery half-time, a time interval from the end of manipulation to the time that tissue hemodynamics reached a half-maximal value. Results Subjects with FM had similar hemodynamic and metabolic response/recovery patterns as healthy controls during exercise and during arterial occlusion. However, tissue rOEF during exercise in subjects with FM was significantly lower than in healthy controls, and the half-times of oxygenation recovery (Δ[HbO2] and Δ[Hb]) were significantly longer following fatiguing exercise and cuff occlusion. Conclusions Our results suggest an alteration of muscle oxygen utilization in the FM population. This study demonstrates the potential of using combined diffuse optical spectroscopies (i.e., NIRS/DCS) to comprehensively evaluate tissue oxygen and flow kinetics in skeletal muscle.
Collapse
|
27
|
Cheng R, Shang Y, Hayes D, Saha SP, Yu G. Noninvasive optical evaluation of spontaneous low frequency oscillations in cerebral hemodynamics. Neuroimage 2012; 62:1445-54. [DOI: 10.1016/j.neuroimage.2012.05.069] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2012] [Revised: 05/11/2012] [Accepted: 05/24/2012] [Indexed: 01/15/2023] Open
|
28
|
Gurley K, Shang Y, Yu G. Noninvasive optical quantification of absolute blood flow, blood oxygenation, and oxygen consumption rate in exercising skeletal muscle. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:075010. [PMID: 22894482 PMCID: PMC3395077 DOI: 10.1117/1.jbo.17.7.075010] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2012] [Revised: 06/11/2012] [Accepted: 06/13/2012] [Indexed: 05/19/2023]
Abstract
This study investigates a method using novel hybrid diffuse optical spectroscopies [near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS)] to obtain continuous, noninvasive measurement of absolute blood flow (BF), blood oxygenation, and oxygen consumption rate (V̇O(2)) in exercising skeletal muscle. Healthy subjects (n=9) performed a handgrip exercise to increase BF and V̇O(2) in forearm flexor muscles, while a hybrid optical probe on the skin surface directly monitored oxy-, deoxy-, and total hemoglobin concentrations ([HbO(2)], [Hb], and THC), tissue oxygen saturation (S(t)O(2)), relative BF (rBF), and relative oxygen consumption rate (rV̇O(2)). The rBF and rV̇O(2) signals were calibrated with absolute baseline BF and V̇O(2) obtained through venous and arterial occlusions, respectively. Known problems with muscle-fiber motion artifacts in optical measurements during exercise were mitigated using a novel gating algorithm that determined muscle contraction status based on control signals from a dynamometer. Results were consistent with previous findings in the literature. This study supports the application of NIRS/DCS technology to quantitatively evaluate hemodynamic and metabolic parameters in exercising skeletal muscle and holds promise for improving diagnosis and treatment evaluation for patients suffering from diseases affecting skeletal muscle and advancing fundamental understanding of muscle and exercise physiology.
Collapse
Affiliation(s)
- Katelyn Gurley
- University of Kentucky, Center for Biomedical Engineering, Lexington, Kentucky 40506
| | - Yu Shang
- University of Kentucky, Center for Biomedical Engineering, Lexington, Kentucky 40506
| | - Guoqiang Yu
- University of Kentucky, Center for Biomedical Engineering, Lexington, Kentucky 40506
- Address all correspondence to: Guoqiang Yu, University of Kentucky, Center for Biomedical Engineering, 204 Wenner-Gren Research Lab, 600 Rose Street, Lexington, Kentucky 40506-0070. Tel: +859 257 9110; Fax: 859 257 1856; E-mail:
| |
Collapse
|