1
|
Pour PH, Suzaei FM, Daryanavard SM. Greenness assessment of microextraction techniques in therapeutic drug monitoring. Bioanalysis 2024; 16:249-278. [PMID: 38466891 PMCID: PMC11216521 DOI: 10.4155/bio-2023-0266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 02/08/2024] [Indexed: 03/13/2024] Open
Abstract
Aim: In this study, we evaluated the greenness and whiteness scores for microextraction techniques used in therapeutic drug monitoring. Additionally, the cons and pros of each evaluated method and their impacts on the provided scores are also discussed. Materials & methods: The Analytical Greenness Sample Preparation metric tool and white analytical chemistry principles are used for related published works (2007-2023). Results & conclusion: This study provided valuable insights for developing methods based on microextraction techniques with a balance in greenness and whiteness areas. Some methods based on a specific technique recorded higher scores, making them suitable candidates as green analytical approaches, and some others achieved high scores both in green and white areas with a satisfactory balance between principles.
Collapse
Affiliation(s)
- Parastoo Hosseini Pour
- Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, 79177, Iran
| | - Foad Mashayekhi Suzaei
- Toxicology Laboratories, Monitoring the Human Hygiene Condition and Standard of Qeshm (MHCS Company), Qeshm Island, 79511, Iran
| | | |
Collapse
|
2
|
Soares S, Rosado T, Barroso M, Gallardo E. Solid Phase-Based Microextraction Techniques in Therapeutic Drug Monitoring. Pharmaceutics 2023; 15:pharmaceutics15041055. [PMID: 37111541 PMCID: PMC10142207 DOI: 10.3390/pharmaceutics15041055] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 03/18/2023] [Accepted: 03/22/2023] [Indexed: 04/29/2023] Open
Abstract
Therapeutic drug monitoring is an established practice for a small group of drugs, particularly those presenting narrow therapeutic windows, for which there is a direct relationship between concentration and pharmacological effects at the site of action. Drug concentrations in biological fluids are used, in addition to other clinical observation measures, to assess the patient's status, since they are the support for therapy individualization and allow assessing adherence to therapy. Monitoring these drug classes is of great importance, as it minimizes the risk of medical interactions, as well as toxic effects. In addition, the quantification of these drugs through routine toxicological tests and the development of new monitoring methodologies are extremely relevant for public health and for the well-being of the patient, and it has implications in clinical and forensic situations. In this sense, the use of new extraction procedures that employ smaller volumes of sample and organic solvents, therefore considered miniaturized and green techniques, is of great interest in this field. From these, the use of fabric-phase extractions seems appealing. Noteworthy is the fact that SPME, which was the first of these miniaturized approaches to be used in the early '90s, is still the most used solventless procedure, providing solid and sound results. The main goal of this paper is to perform a critical review of sample preparation techniques based on solid-phase microextraction for drug detection in therapeutic monitoring situations.
Collapse
Affiliation(s)
- Sofia Soares
- Centro de Investigação em Ciências da Saúde, Faculdade de Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal
- Laboratório de Fármaco-Toxicologia, Ubimedical, Universidade da Beira Interior, 6200-284 Covilhã, Portugal
| | - Tiago Rosado
- Centro de Investigação em Ciências da Saúde, Faculdade de Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal
- Laboratório de Fármaco-Toxicologia, Ubimedical, Universidade da Beira Interior, 6200-284 Covilhã, Portugal
| | - Mário Barroso
- Serviço de Química e Toxicologia Forenses, Instituto de Medicina Legal e Ciências Forenses-Delegação do Sul, 1169-201 Lisboa, Portugal
| | - Eugenia Gallardo
- Centro de Investigação em Ciências da Saúde, Faculdade de Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal
- Laboratório de Fármaco-Toxicologia, Ubimedical, Universidade da Beira Interior, 6200-284 Covilhã, Portugal
| |
Collapse
|
3
|
Xu L, Hu ZS, Duan R, Wang X, Yang YS, Dong LY, Wang XH. Advances and applications of in-tube solid-phase microextraction for analysis of proteins. J Chromatogr A 2021; 1640:461962. [PMID: 33582517 DOI: 10.1016/j.chroma.2021.461962] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 01/27/2021] [Accepted: 01/28/2021] [Indexed: 12/29/2022]
Abstract
In-tube solid-phase microextraction (IT-SPME) with capillary column as extraction device is a well-established green extraction technique with a lot of applications in the fields of biomedicine, food and environment. This article reviews the research contributions of IT-SPME for analysis of proteins. The paper first briefly describes the history of IT-SPME. Then, the development and principle of IT-SPME for analysis of proteins are introduced, in which capillary column configurations of IT-SPME and instruments for quantitative analysis of proteins are summarized. Subsequently, the synthesis strategy and recognition principle of different recognition units, including antibodies, aptamers, molecularly imprinted polymers, and boronate affinity materials, are discussed in detail. This part also introduces several rare recognition units, including lectins, restricted access materials, lysine modified with β-cyclodextrin and cell membrane. The development trend and possible future direction of IT-SPME for analysis of proteins are mentioned.
Collapse
Affiliation(s)
- Liang Xu
- School of Pharmacy, Tianjin Medical University, Tianjin, 300070, PR China; Tianjin Medical College, Tianjin, 300222, PR China.
| | - Zhan-Song Hu
- Department of pharmacy, Tianjin Chest Hospital, 300222, PR China
| | - Rui Duan
- School of Pharmacy, Tianjin Medical University, Tianjin, 300070, PR China
| | - Xuan Wang
- School of Pharmacy, Tianjin Medical University, Tianjin, 300070, PR China
| | - Yuan-Shuo Yang
- School of Pharmacy, Tianjin Medical University, Tianjin, 300070, PR China
| | - Lin-Yi Dong
- School of Pharmacy, Tianjin Medical University, Tianjin, 300070, PR China
| | - Xian-Hua Wang
- School of Pharmacy, Tianjin Medical University, Tianjin, 300070, PR China.
| |
Collapse
|
4
|
Kataoka H. In-tube solid-phase microextraction: Current trends and future perspectives. J Chromatogr A 2020; 1636:461787. [PMID: 33359971 DOI: 10.1016/j.chroma.2020.461787] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 12/02/2020] [Accepted: 12/04/2020] [Indexed: 01/01/2023]
Abstract
In-tube solid-phase microextraction (IT-SPME) was developed about 24 years ago as an effective sample preparation technique using an open tubular capillary column as an extraction device. IT-SPME is useful for micro-concentration, automated sample cleanup, and rapid online analysis, and can be used to determine the analytes in complex matrices simple sample processing methods such as direct sample injection or filtration. IT-SPME is usually performed in combination with high-performance liquid chromatography using an online column switching technology, in which the entire process from sample preparation to separation to data analysis is automated using the autosampler. Furthermore, IT-SPME minimizes the use of harmful organic solvents and is simple and labor-saving, making it a sustainable and environmentally friendly green analytical technique. Various operating systems and new sorbent materials have been developed to improve its extraction efficiency by, for example, enhancing its sorption capacity and selectivity. In addition, IT-SPME methods have been widely applied in environmental analysis, food analysis and bioanalysis. This review describes the present state of IT-SPME technology and summarizes its current trends and future perspectives, including method development and strategies to improve extraction efficiency.
Collapse
Affiliation(s)
- Hiroyuki Kataoka
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan.
| |
Collapse
|
5
|
Protti M, Mandrioli R, Mercolini L. Quantitative microsampling for bioanalytical applications related to the SARS-CoV-2 pandemic: Usefulness, benefits and pitfalls. J Pharm Biomed Anal 2020; 191:113597. [PMID: 32927419 PMCID: PMC7456588 DOI: 10.1016/j.jpba.2020.113597] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 08/23/2020] [Accepted: 08/25/2020] [Indexed: 12/20/2022]
Abstract
The multiple pathological effects of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, and its total novelty, mean that currently a lot of diagnostic and therapeutic tools, established and tentative alike, are needed to treat patients in a timely, effective way. In order to make these tools more reliable, faster and more feasible, biological fluid microsampling techniques could provide many advantages. In this review, the most important microsampling techniques are considered (dried matrix spots, volumetric absorptive microsampling, microfluidics and capillary microsampling, solid phase microextraction) and their respective advantages and disadvantages laid out. Moreover, currently available microsampling applications of interest for SARS-CoV-2 therapy are described, in order to make them as much widely known as possible, hopefully providing useful information to researchers and clinicians alike.
Collapse
Affiliation(s)
- Michele Protti
- Research Group of Pharmaco-Toxicological Analysis (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna, Via Belmeloro 6, 40126 Bologna, Italy
| | - Roberto Mandrioli
- Department for Life Quality Studies, Alma Mater Studiorum - University of Bologna, Corso d'Augusto 237, 47921 Rimini, Italy
| | - Laura Mercolini
- Research Group of Pharmaco-Toxicological Analysis (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna, Via Belmeloro 6, 40126 Bologna, Italy.
| |
Collapse
|
6
|
Manousi N, Tzanavaras PD, Zacharis CK. Bioanalytical HPLC Applications of In-Tube Solid Phase Microextraction: A Two-Decade Overview. Molecules 2020; 25:molecules25092096. [PMID: 32365828 PMCID: PMC7248733 DOI: 10.3390/molecules25092096] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 04/28/2020] [Accepted: 04/29/2020] [Indexed: 12/18/2022] Open
Abstract
In-tube solid phase microextraction is a cutting-edge sample treatment technique offering significant advantages in terms of miniaturization, green character, automation, and preconcentration prior to analysis. During the past years, there has been a considerable increase in the reported publications, as well as in the research groups focusing their activities on this technique. In the present review article, HPLC bioanalytical applications of in-tube SPME are discussed, covering a wide time frame of twenty years of research reports. Instrumental aspects towards the coupling of in-tube SPME and HPLC are also discussed, and detailed information on materials/coatings and applications in biological samples are provided.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece; (N.M.); (P.D.T.)
| | - Paraskevas D. Tzanavaras
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece; (N.M.); (P.D.T.)
| | - Constantinos K. Zacharis
- Laboratory of Pharmaceutical Analysis, Department of Pharmaceutical Technology, School of Pharmacy, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece
- Correspondence: ; Tel.: +30-231-099-7663
| |
Collapse
|
7
|
Pan J, Song Y, Xu B, Liu J, Fu L, Xu L. Preparation and application of immunoaffinity in-tube solid phase microextraction column with oriented antibody-immobilized porous layer open tubular capillary for high sensitive quantification of serum extracellular domain of human epidermal growth factor receptor 2 levels. J Chromatogr A 2020; 1619:460974. [PMID: 32087879 DOI: 10.1016/j.chroma.2020.460974] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2019] [Revised: 02/07/2020] [Accepted: 02/11/2020] [Indexed: 11/20/2022]
Abstract
Human epidermal growth factor receptor 2 (HER2) gene expresses a transmembrane glycoprotein that is over-expressed in 15-30% breast, 3% lung, and other several digestive cancers. So HER2 is a good biomarker for tumor diagnostic and treatment monitoring. Clinically, detection of HER2 often employs invasive approaches with tissue samples, which at large extent limit its universal application. Shedding of the extracellular domain (ECD) of the HER2 (HER2-ECD) into the circulation has led to the development of a serum test of HER2-ECD as an additional approach to probe the HER2 overexpression. However, few methods were developed due to the high sensitivity required by the serum HER2-ECD determination. In this work, we prepared a novel immunoaffinity in-tube solid phase microextraction (IT-SPME) sorbent for selective enrichment of HER2-ECD. Two clinical available monoclonal antibodies against to HER2, trastuzumab and pertuzumab, were selected as immunoaffinity ligands. Porous layer open tubular capillary with oriented antibody immobilization were fabricated and systematically optimized to afford a higher extraction capacity. The capacity was reached to 120.4 μg/m, which is more than 1000 times higher than that obtained by a common method (directly antibody immobilization on a naked capillary). After sample extraction and enrichment by the IT-SPME, the eluent were determined by a particle-enhanced turbidimetric immunoassay (PETIA). Sensitive quantification of HER2-ECD by the PETIA was thereby accomplished. HER2-ECD concentrations in 82 clinical serum samples were determined by the developed IT-SPME/PETIA method, and the results were well-correlated with that by the clinical used chemiluminescence immunoassay (CLIA). Besides, the IT-SPME/PETIA method was found providing 5 times higher sensitivity than the CLIA, and 500 times higher than the PETIA without IT-SPME. The results indicate that the developed method is suitable for high-sensitive quantification of HER2-ECD in clinical samples.
Collapse
Affiliation(s)
- Jianhui Pan
- Graduate School, Tianjin Medical University, Tianjin, 300070, China; Tianjin Chest Hospital, Tianjin, 300222, China
| | - Yang Song
- Graduate School, Tianjin Medical University, Tianjin, 300070, China; School of Pharmacy, Tianjin Medical University, Tianjin, 300070, China; Sinopharm Group (Tianjin) East Bookcom Pharmaceutical Co., Ltd, Tianjin, 300051, China
| | - Bei Xu
- School of Public Health, Tianjin Medical University, Tianjin, 300070, China
| | - Jiyang Liu
- Tianjin Medical College, Tianjin, 300222, China
| | - Li Fu
- Department of Breast Cancer Pathology and Research Laboratory, State Key Laboratory of Breast Cancer Research, Cancer Hospital of Tianjin Medical University, Tianjin, 300060, China.
| | - Liang Xu
- School of Pharmacy, Tianjin Medical University, Tianjin, 300070, China; Tianjin Medical College, Tianjin, 300222, China; Department of Breast Cancer Pathology and Research Laboratory, State Key Laboratory of Breast Cancer Research, Cancer Hospital of Tianjin Medical University, Tianjin, 300060, China.
| |
Collapse
|
8
|
Marchioni C, Vieira TM, Miller Crotti AE, Crippa JA, Costa Queiroz ME. In-tube solid-phase microextraction with a dummy molecularly imprinted monolithic capillary coupled to ultra-performance liquid chromatography-tandem mass spectrometry to determine cannabinoids in plasma samples. Anal Chim Acta 2020; 1099:145-154. [DOI: 10.1016/j.aca.2019.11.017] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Revised: 11/01/2019] [Accepted: 11/04/2019] [Indexed: 10/25/2022]
|
9
|
Huang S, Chen G, Ye N, Kou X, Zhu F, Shen J, Ouyang G. Solid-phase microextraction: An appealing alternative for the determination of endogenous substances - A review. Anal Chim Acta 2019; 1077:67-86. [PMID: 31307724 DOI: 10.1016/j.aca.2019.05.054] [Citation(s) in RCA: 69] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Revised: 05/22/2019] [Accepted: 05/23/2019] [Indexed: 02/07/2023]
Abstract
The determination of endogenous substances is of great significance for obtaining important biotic information such as biological components, metabolic pathways and disease biomarkers in different living organisms (e.g. plants, insects, animals and humans). However, due to the complex matrix and the trace concentrations of target analytes, the sample preparation procedure is an essential step before the analytes of interest are introduced into a detection instrument. Solid-phase microextraction (SPME), an emerging sample preparation technique that integrates sampling, extraction, concentration, and sample introduction into one step, has gained wide acceptance in various research fields, including in the determination of endogenous compounds. In this review, recent developments and applications of SPME for the determination of endogenous substances over the past five years are summarized. Several aspects, including the design of SPME devices (sampling configuration and coating), applications (in vitro and in vivo sampling), and coupling with emerging instruments (comprehensive two-dimensional gas chromatography (GC × GC), ambient mass spectrometry (AMS) and surface enhanced Raman scattering (SERS)) are involved. Finally, the challenges and opportunities of SPME methods in endogenous substances analysis are also discussed.
Collapse
Affiliation(s)
- Siming Huang
- Department of Radiology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, China
| | - Guosheng Chen
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Niru Ye
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Xiaoxue Kou
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Fang Zhu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Jun Shen
- Department of Radiology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, No. 107 Yanjiang Road West, Guangzhou, 510120, China.
| | - Gangfeng Ouyang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China; College of Chemistry & Molecular Engineering, Center of Advanced Analysis and Computational Science, Zhengzhou University, Kexue Avenue 100, Zhengzhou, 450001, PR China.
| |
Collapse
|
10
|
|
11
|
Butyl Methacrylate-Co-Ethylene Glycol Dimethacrylate Monolith for Online in-Tube SPME-UHPLC-MS/MS to Determine Chlopromazine, Clozapine, Quetiapine, Olanzapine, and Their Metabolites in Plasma Samples. Molecules 2019; 24:molecules24020310. [PMID: 30654481 PMCID: PMC6359403 DOI: 10.3390/molecules24020310] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Revised: 01/10/2019] [Accepted: 01/12/2019] [Indexed: 11/16/2022] Open
Abstract
This manuscript describes a sensitive, selective, and online in-tube solid-phase microextraction coupled with an ultrahigh performance liquid chromatography-tandem mass spectrometry (in-tube SPME-UHPLC-MS/MS) method to determine chlopromazine, clozapine, quetiapine, olanzapine, and their metabolites in plasma samples from schizophrenic patients. Organic poly(butyl methacrylate-co-ethylene glycol dimethacrylate) monolith was synthesized on the internal surface of a fused silica capillary (covalent bonds) for in-tube SPME. Analyte extraction and analysis was conducted by connecting the monolithic capillary to an UHPLC-MS/MS system. The monolith was characterized by scanning electron microscopy (SEM) and Fourier transform infrared spectrometry (FTIR). The developed method presented adequate linearity for all the target antipsychotics: R² was higher than 0.9975, lack-of-fit ranged from 0.115 to 0.955, precision had variation coefficients lower than 14.2%, and accuracy had relative standard error values ranging from -13.5% to 14.6%, with the exception of the lower limit of quantification (LLOQ). The LLOQ values in plasma samples were 10 ng mL-1 for all analytes. The developed method was successfully applied to determine antipsychotics and their metabolites in plasma samples from schizophrenic patients.
Collapse
|
12
|
Ying LL, Ma YC, Xu B, Wang XH, Dong LY, Wang DM, Liu K, Xu L. Poly(glycidyl methacrylate) nanoparticle-coated capillary with oriented antibody immobilization for immunoaffinity in-tube solid phase microextraction: Preparation and characterization. J Chromatogr A 2017. [DOI: 10.1016/j.chroma.2017.06.023] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
13
|
In-tube solid-phase microextraction based on NH 2 -MIL-53(Al)-polymer monolithic column for online coupling with high-performance liquid chromatography for directly sensitive analysis of estrogens in human urine. Talanta 2017; 165:377-383. [DOI: 10.1016/j.talanta.2016.12.050] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Revised: 12/16/2016] [Accepted: 12/20/2016] [Indexed: 11/30/2022]
|
14
|
Marchioni C, de Souza ID, Grecco CF, Crippa JA, Tumas V, Queiroz MEC. A column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry method to determine anandamide and 2-arachidonoylglycerol in plasma samples. Anal Bioanal Chem 2017; 409:3587-3596. [PMID: 28337517 DOI: 10.1007/s00216-017-0300-3] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Revised: 02/17/2017] [Accepted: 03/03/2017] [Indexed: 12/11/2022]
Abstract
This study reports a fast, sensitive, and selective column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to determine the endocannabinoids (eCBs), anandamide (AEA), and 2-arachidonoylglycerol (2-AG) in plasma samples. This bidimensional system used a restricted access media column (RP-8 ADS, 25 mm × 4 mm × 25 μM) in the first dimension and a core-shell Kinetex C18 (100 mm × 2, 1.7 mm × 1 μM) column in the second dimension, followed by detection in a mass spectrometer triple quadrupole (multiple reactions monitoring mode) operating in the positive mode. RP-8 ADS was used for trace enrichment of eCBs (reverse phase partitioning) and macromolecular matrix size exclusion; the core-shell column was used for the chromatographic separation. The column switching UHPLC-MS/MS method presented a linear range spanning from 0.1 ng mL-1 (LOQ) to 6 ng mL-1 for AEA and from 0.04 ng mL-1 (LOQ) to 10 ng mL-1 for 2-AG. Excluding the LLOQ values, the precision assays provided coefficients of variation lower than 8% and accuracy with relative standard error values lower than 14%. Neither carryover nor matrix effects were detected. This high-throughput column switching method compared to conventional methods is time saving as it involves fewer steps, consumes less solvent, and presents lower LLOQ. The column switching UHPLC-MS/MS method was successfully applied to determine AEA and 2-AG in plasma samples obtained from Alzheimer's disease patients. Graphical abstract A column switching ultra high-performance liquid chromatography-tandem mass spectrometry method using RP-8 ADS column and core shell column to determine endocannabinoids in plasma samples.
Collapse
Affiliation(s)
- Camila Marchioni
- Faculdade de Ciências Farmacêuticas de Ribeirão Preto, Universidade de São Paulo (USP), Avenida Bandeirantes, 3900, São Paulo, Ribeirão Preto, CEP 14040-901, Brazil
| | - Israel Donizeti de Souza
- Departamento de Química, Universidade de São Paulo (USP), Avenida Bandeirantes, 3900, São Paulo, Ribeirão Preto, CEP 14040-901, Brazil
| | - Caroline Fernandes Grecco
- Departamento de Química, Universidade de São Paulo (USP), Avenida Bandeirantes, 3900, São Paulo, Ribeirão Preto, CEP 14040-901, Brazil
| | - José Alexandre Crippa
- Department of Neuroscience and Behavior, Ribeirão Preto Medical School, University of São Paulo, São Paulo, Brazil
| | - Vitor Tumas
- Department of Neuroscience and Behavior, Ribeirão Preto Medical School, University of São Paulo, São Paulo, Brazil
| | - Maria Eugênia Costa Queiroz
- Faculdade de Ciências Farmacêuticas de Ribeirão Preto, Universidade de São Paulo (USP), Avenida Bandeirantes, 3900, São Paulo, Ribeirão Preto, CEP 14040-901, Brazil.
- Departamento de Química, Universidade de São Paulo (USP), Avenida Bandeirantes, 3900, São Paulo, Ribeirão Preto, CEP 14040-901, Brazil.
| |
Collapse
|
15
|
Column switching UHPLC–MS/MS with restricted access material for the determination of CNS drugs in plasma samples. Bioanalysis 2017; 9:555-568. [DOI: 10.4155/bio-2016-0301] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Background: Polypharmacy is a common practice in schizophrenia. Consequently, therapeutic drug monitoring is usually adopted to maintain the concentrations of the drugs in the plasma within a targeted therapeutic range, to maximize therapeutic efficiency and to diminish adverse side effects. Methodology: This study reports on a column switching UHPLC–MS/MS method to determine psychotropic drugs in plasma samples simultaneously. Results: The method was linear from 0.025 to 1.25 ng ml-1 with R2 above 0.9950 and the lack of fit test (p > 0.05). The precision values presented coefficients of variation lower than 12%, and the relative standard error of the accuracy were lower than 14%. Conclusion: The column switching UHPLC–MS/MS method developed herein successfully determined drugs in schizophrenic patients’ plasma samples for therapeutic drug monitoring.
Collapse
|
16
|
Serra-Mora P, Moliner-Martínez Y, Molins-Legua C, Herráez-Hernández R, Verdú-Andrés J, Campíns-Falcó P. Trends in Online Intube Solid Phase Microextraction. COMPREHENSIVE ANALYTICAL CHEMISTRY 2017. [DOI: 10.1016/bs.coac.2017.01.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
17
|
Fernández-Amado M, Prieto-Blanco M, López-Mahía P, Muniategui-Lorenzo S, Prada-Rodríguez D. Strengths and weaknesses of in-tube solid-phase microextraction: A scoping review. Anal Chim Acta 2016; 906:41-57. [DOI: 10.1016/j.aca.2015.12.007] [Citation(s) in RCA: 85] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2015] [Revised: 11/30/2015] [Accepted: 12/11/2015] [Indexed: 12/01/2022]
|
18
|
Determination of 11 quinolones in bovine milk using immunoaffinity stir bar sorptive microextraction and liquid chromatography with fluorescence detection. J Chromatogr B Analyt Technol Biomed Life Sci 2015; 1003:67-73. [DOI: 10.1016/j.jchromb.2015.09.008] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2015] [Revised: 09/07/2015] [Accepted: 09/09/2015] [Indexed: 11/23/2022]
|
19
|
Shimazaki Y, Takatsu Y. Combined Method of Immunoaffinity Membrane Within Tubes and MALDI-TOF MS for Capturing and Analyzing Amyloid Beta. Appl Biochem Biotechnol 2015; 177:1565-71. [DOI: 10.1007/s12010-015-1837-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2015] [Accepted: 09/07/2015] [Indexed: 12/20/2022]
|
20
|
Souza-Silva ÉA, Reyes-Garcés N, Gómez-Ríos GA, Boyacı E, Bojko B, Pawliszyn J. A critical review of the state of the art of solid-phase microextraction of complex matrices III. Bioanalytical and clinical applications. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.04.017] [Citation(s) in RCA: 180] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
21
|
Abstract
Biomedical analyses of drugs and their metabolites are important in new drug development, therapeutic drug monitoring and forensic toxicology. In these analyses, sample preparation is very important to isolate target compounds from complex biological matrices and markedly influences the reliability and accuracy of determination. SPME is a simple and convenient sample preparation technique that has enabled automation, miniaturization and high-throughput performance. This article focuses on current developments, their biomedical applications and future trends with emphasis on new extraction devices using selective polymer coating materials in novel SPME techniques, including fiber SPME, in-tube SPME and related techniques.
Collapse
|
22
|
Moliner-Martinez Y, Herráez-Hernández R, Verdú-Andrés J, Molins-Legua C, Campíns-Falcó P. Recent advances of in-tube solid-phase microextraction. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.02.020] [Citation(s) in RCA: 105] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
23
|
Xu B, Cheng S, Wang X, Wang D, Xu L. Novel polystyrene/antibody nanoparticle-coated capillary for immunoaffinity in-tube solid-phase microextraction. Anal Bioanal Chem 2015; 407:2771-5. [DOI: 10.1007/s00216-014-8419-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2014] [Revised: 12/04/2014] [Accepted: 12/15/2014] [Indexed: 10/24/2022]
|
24
|
Wang L, Zang X, Wang C, Wang Z. Graphene oxide as a micro-solid-phase extraction sorbent for the enrichment of parabens from water and vinegar samples. J Sep Sci 2014; 37:1656-62. [DOI: 10.1002/jssc.201400028] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2014] [Revised: 04/04/2014] [Accepted: 04/04/2014] [Indexed: 12/18/2022]
Affiliation(s)
- Lu Wang
- Department of Chemistry; College of Science; Agricultural University of Hebei; Hebei China
| | - Xiaohuan Zang
- Department of Chemistry; College of Science; Agricultural University of Hebei; Hebei China
| | - Chun Wang
- Department of Chemistry; College of Science; Agricultural University of Hebei; Hebei China
| | - Zhi Wang
- Department of Chemistry; College of Science; Agricultural University of Hebei; Hebei China
| |
Collapse
|
25
|
Yang Y, Lord H, Pawliszyn J. A new strategy to eliminate sample mixing during in-tube solid phase microextraction. J Chromatogr A 2014; 1318:12-21. [PMID: 24353998 DOI: 10.1016/j.chroma.2013.10.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
During in-tube solid phase microextraction, sample mixing with mobile phase contained in the autosampler tubing during extraction may result in some amount of sample becoming entrained in the mobile phase rather than returning to the sample vial or being directed to waste after extraction. In cases where target analytes have relatively low affinity for the sorbent on the wall of the capillary, mixing can impact data quality. Where the sample contains components that may interfere with either the separation (e.g. proteins) or detection (e.g. ions with MS detection), additional difficulties can arise. In the current research, the magnitude of the sample mixing effect was illustrated by analyzing ranitidine and a series of polycyclic aromatic hydrocarbons (PAH). The sample volume equivalent of mixing was calculated as 37 μL for ranitidine and 20 μL for PAHs using the same inner diameter of capillary. To address this issue, a novel approach involving adding a switching valve located between the metering pump and the capillary was developed. Capillary flush conditions, draw/eject speed and extraction time were optimized for ranitidine with the result that in the final method, no mixing of sample with mobile phase was apparent in the detected amounts. To provide information on a compound class with intermediate polarity, two -blockers were also extracted using the optimized washing conditions respectively. The results indicated that the issue of sample mixing had been resolved for these as well. Finally, in-tube SPME calibration of these three analyte classes was shown to be highly linear, providing further indication that sample mixing was not impacting data quality. Available literature on the subject was surveyed, and a discussion on the rational selection of conditions to guide method development was also provided.
Collapse
|
26
|
Queiroz M, Melo L. Selective capillary coating materials for in-tube solid-phase microextraction coupled to liquid chromatography to determine drugs and biomarkers in biological samples: A review. Anal Chim Acta 2014; 826:1-11. [DOI: 10.1016/j.aca.2014.03.024] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2013] [Revised: 03/10/2014] [Accepted: 03/17/2014] [Indexed: 11/25/2022]
|
27
|
Moein MM, Said R, Bassyouni F, Abdel-Rehim M. Solid phase microextraction and related techniques for drugs in biological samples. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2014; 2014:921350. [PMID: 24688797 PMCID: PMC3943203 DOI: 10.1155/2014/921350] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/27/2013] [Revised: 10/24/2013] [Accepted: 10/25/2013] [Indexed: 06/03/2023]
Abstract
In drug discovery and development, the quantification of drugs in biological samples is an important task for the determination of the physiological performance of the investigated drugs. After sampling, the next step in the analytical process is sample preparation. Because of the low concentration levels of drug in plasma and the variety of the metabolites, the selected extraction technique should be virtually exhaustive. Recent developments of sample handling techniques are directed, from one side, toward automatization and online coupling of sample preparation units. The primary objective of this review is to present the recent developments in microextraction sample preparation methods for analysis of drugs in biological fluids. Microextraction techniques allow for less consumption of solvent, reagents, and packing materials, and small sample volumes can be used. In this review the use of solid phase microextraction (SPME), microextraction in packed sorbent (MEPS), and stir-bar sorbtive extraction (SBSE) in drug analysis will be discussed. In addition, the use of new sorbents such as monoliths and molecularly imprinted polymers will be presented.
Collapse
Affiliation(s)
- Mohammad Mahdi Moein
- Department of Chemistry, Amirkabir University of Technology, Tehran, Iran
- Department of Analytical Chemistry, Stockholm University, SE10691 Stockholm, Sweden
| | - Rana Said
- Department of Analytical Chemistry, Stockholm University, SE10691 Stockholm, Sweden
| | | | - Mohamed Abdel-Rehim
- Department of Analytical Chemistry, Stockholm University, SE10691 Stockholm, Sweden
- National Research Center of Egypt, Cairo 12622, Egypt
| |
Collapse
|
28
|
Pereira J, Silva CL, Perestrelo R, Gonçalves J, Alves V, Câmara JS. Re-exploring the high-throughput potential of microextraction techniques, SPME and MEPS, as powerful strategies for medical diagnostic purposes. Innovative approaches, recent applications and future trends. Anal Bioanal Chem 2014; 406:2101-22. [DOI: 10.1007/s00216-013-7527-4] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2013] [Revised: 11/16/2013] [Accepted: 11/20/2013] [Indexed: 11/30/2022]
|
29
|
Bylda C, Thiele R, Kobold U, Volmer DA. Recent advances in sample preparation techniques to overcome difficulties encountered during quantitative analysis of small molecules from biofluids using LC-MS/MS. Analyst 2014; 139:2265-76. [DOI: 10.1039/c4an00094c] [Citation(s) in RCA: 181] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
30
|
Chaves AR, Costa Queiroz ME. In-tube solid-phase microextraction with molecularly imprinted polymer to determine interferon alpha 2a in plasma sample by high performance liquid chromatography. J Chromatogr A 2013; 1318:43-8. [DOI: 10.1016/j.chroma.2013.10.018] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|