1
|
Fan CH, Yeh CK. Theranostic nanomaterials for intervention of the blood–brain barrier. THERANOSTICS NANOMATERIALS IN DRUG DELIVERY 2025:395-410. [DOI: 10.1016/b978-0-443-22044-9.00014-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
|
2
|
Liang Y, Zhang S, Wang D, Ji P, Zhang B, Wu P, Wang L, Liu Z, Wang J, Duan Y, Yuan L. Dual-Functional Nanodroplet for Tumor Vasculature Ultrasound Imaging and Tumor Immunosuppressive Microenvironment Remodeling. Adv Healthc Mater 2024; 13:e2401274. [PMID: 39031111 DOI: 10.1002/adhm.202401274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Revised: 06/24/2024] [Indexed: 07/22/2024]
Abstract
Accurately evaluating tumor neoangiogenesis and conducting precise interventions toward an immune-favorable microenvironment are of significant clinical importance. In this study, a novel nanodroplet termed as the nanodroplet-based ultrasound contrast agent and therapeutic (NDsUCA/Tx) is designed for ultrasound imaging and precise interventions of tumor neoangiogenesis. Briefly, the NDsUCA/Tx shell is constructed from an engineered CMs containing the tumor antigen, vascular endothelial growth factor receptor 1 (VEGFR1) extracellular domain 2-3, and CD93 ligand multimerin 2. The core is composed of perfluorohexane and the immune adjuvant R848. After injection, NDsUCA/Tx is found to be enriched in the tumor vasculature with high expression of CD93. When triggered by ultrasound, the perfluorohexane in NDsUCA/Tx underwent acoustic droplet vaporization and generated an enhanced ultrasound signal. Some microbubbles exploded and the resultant debris (with tumor antigen and R848) together with the adsorbed VEGF are taken up by nearby cells. This cleared the local VEGF for vascular normalization, and also served as a vaccine to activate the immune response. Using a syngeneic mouse model, the satisfactory performance of NDsUCA/Tx in tumor vasculature imaging and immune activation is confirmed. Thus, a multifunctional NDsUCA/Tx is successfully developed for molecular imaging of tumor neoangiogenesis and precise remodeling of the tumor microenvironment.
Collapse
Affiliation(s)
- Yuan Liang
- Department of Ultrasound Diagnostics, Tangdu Hospital, Air Force Medical University, Xi'an, 710038, P. R. China
| | - Siyan Zhang
- Department of Ultrasound Diagnostics, Tangdu Hospital, Air Force Medical University, Xi'an, 710038, P. R. China
| | - Dingyi Wang
- Department of Ultrasound Diagnostics, Tangdu Hospital, Air Force Medical University, Xi'an, 710038, P. R. China
| | - Panpan Ji
- Department of Digestive Surgery Xijing Hospital, Air Force Medical University, Xi'an, 710032, P. R. China
| | - Bin Zhang
- Department of Ultrasound Diagnostics, Tangdu Hospital, Air Force Medical University, Xi'an, 710038, P. R. China
| | - Pengying Wu
- Department of Ultrasound Diagnostics, Tangdu Hospital, Air Force Medical University, Xi'an, 710038, P. R. China
| | - Lantian Wang
- Department of Ultrasound Diagnostics, Tangdu Hospital, Air Force Medical University, Xi'an, 710038, P. R. China
| | - Zhaoyou Liu
- Department of Ultrasound Diagnostics, Tangdu Hospital, Air Force Medical University, Xi'an, 710038, P. R. China
| | - Jia Wang
- Department of Ultrasound Diagnostics, Tangdu Hospital, Air Force Medical University, Xi'an, 710038, P. R. China
| | - Yunyou Duan
- Department of Ultrasound Diagnostics, Tangdu Hospital, Air Force Medical University, Xi'an, 710038, P. R. China
| | - Lijun Yuan
- Department of Ultrasound Diagnostics, Tangdu Hospital, Air Force Medical University, Xi'an, 710038, P. R. China
| |
Collapse
|
3
|
Vidallon MLP, Liu H, Lu Z, Acter S, Song Y, Baldwin C, Teo BM, Bishop AI, Tabor RF, Peter K, de Campo L, Wang X. Polydopamine Nanobowl-Armoured Perfluorocarbon Emulsions: Tracking Thermal- and Photothermal-Induced Phase Change through Neutron Scattering. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024:e2406019. [PMID: 39523733 DOI: 10.1002/smll.202406019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2024] [Revised: 10/29/2024] [Indexed: 11/16/2024]
Abstract
Anisotropic polydopamine nanobowls (PDA NBs) show significant promise in biomedicine, distinguished by their unique optical properties and superior cellular uptake compared to spherical nanoparticles. This study presents a novel approach for creating multistimuli-activated PDA NB-armored emulsions, encapsulating perfluorohexane (NB-H) and perfluoropentane (NB-P) cores, with applications in controlled delivery and ultrasound imaging. Thermal and photothermal activation induced distinct responses in the emulsions, as evidenced by optical microscopy and thermogravimetric analysis. For the first time, neutron scattering techniques (SANS and USANS) under contrast matching conditions are applied to investigate these materials, revealing detailed droplet and microbubble structures and phase transition dynamics. These results show that NB-H droplets resist phase change under direct heating, whereas NB-P droplets respond more readily, exhibiting significant bubble formation. During photothermal activation with short near-infrared (NIR) exposure (15 min at 400 mW cm-2), SANS and USANS analyses reveal varying degrees of phase transition, proving this activation method to be more effective than direct heating. Importantly, NB-H and NB-P droplets have excellent ultrasound contrast enhancement and biocompatibility, indicating their potential for contrast-enhanced ultrasound imaging, theranostics, and photothermal applications. This comprehensive study advances the understanding of multifunctional colloidal materials in biomedicine, contributing essential knowledge to this rapidly evolving field.
Collapse
Affiliation(s)
- Mark Louis P Vidallon
- Molecular Imaging and Theranostics Laboratory, Baker Heart and Diabetes Institute, 75 Commercial Road, Melbourne, VIC, 3004, Australia
- Baker Department of Cardiometabolic Health, University of Melbourne, Parkville, VIC, 3010, Australia
- School of Chemistry, Monash University, Clayton, VIC, 3800, Australia
- Baker Department of Cardiovascular Research, Translation and Implementation, La Trobe University, Bundoora, VIC, 3086, Australia
| | - Haikun Liu
- Molecular Imaging and Theranostics Laboratory, Baker Heart and Diabetes Institute, 75 Commercial Road, Melbourne, VIC, 3004, Australia
- Baker Department of Cardiometabolic Health, University of Melbourne, Parkville, VIC, 3010, Australia
| | - Zhenzhen Lu
- Department of Chemical Engineering, University of Melbourne, Parkville, 3010, Australia
| | - Shahinur Acter
- Department of Radiation Oncology and Molecular Sciences, The Johns Hopkins School of Medicine, Johns Hopkins University, 733 N Broadway, Baltimore, MD, 21205, USA
| | - Yuyang Song
- Molecular Imaging and Theranostics Laboratory, Baker Heart and Diabetes Institute, 75 Commercial Road, Melbourne, VIC, 3004, Australia
- Baker Department of Cardiometabolic Health, University of Melbourne, Parkville, VIC, 3010, Australia
| | - Chris Baldwin
- Australian Nuclear Science and Technology Organization (ANSTO), New Illawarra Rd, Lucas Heights, NSW, 2234, Australia
| | - Boon Mian Teo
- School of Chemistry, Monash University, Clayton, VIC, 3800, Australia
| | - Alexis I Bishop
- School of Physics and Astronomy, Monash University, Clayton, VIC, 3800, Australia
| | - Rico F Tabor
- School of Chemistry, Monash University, Clayton, VIC, 3800, Australia
| | - Karlheinz Peter
- Baker Department of Cardiometabolic Health, University of Melbourne, Parkville, VIC, 3010, Australia
- Baker Department of Cardiovascular Research, Translation and Implementation, La Trobe University, Bundoora, VIC, 3086, Australia
- Atherothrombosis and Vascular Biology Laboratory, Baker Heart and Diabetes Institute, 75 Commercial Road, Melbourne, VIC, 3004, Australia
- School of Translational Medicine, Monash University, Melbourne, VIC, 3004, Australia
| | - Liliana de Campo
- Australian Nuclear Science and Technology Organization (ANSTO), New Illawarra Rd, Lucas Heights, NSW, 2234, Australia
| | - Xiaowei Wang
- Molecular Imaging and Theranostics Laboratory, Baker Heart and Diabetes Institute, 75 Commercial Road, Melbourne, VIC, 3004, Australia
- Baker Department of Cardiometabolic Health, University of Melbourne, Parkville, VIC, 3010, Australia
- Baker Department of Cardiovascular Research, Translation and Implementation, La Trobe University, Bundoora, VIC, 3086, Australia
- School of Translational Medicine, Monash University, Melbourne, VIC, 3004, Australia
| |
Collapse
|
4
|
Han B, Liu Y, Zhou Q, Yu Y, Liu X, Guo Y, Zheng X, Zhou M, Yu H, Wang W. The advance of ultrasound-enabled diagnostics and therapeutics. J Control Release 2024; 375:1-19. [PMID: 39208935 DOI: 10.1016/j.jconrel.2024.08.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 07/27/2024] [Accepted: 08/25/2024] [Indexed: 09/04/2024]
Abstract
Point-of-care ultrasound demonstrates significant potential in biomedical research due to its noninvasive, real-time visualization, cost-effectiveness, and other biological benefits. Ultrasound irradiation can precisely control the mechanical and physicochemical effects on pathogenic lesions, enabling real-time visualization, tunable tissue penetration depth, and therapeutic applications. This review summarizes recent advancements in ultrasound-enabled diagnostics and therapeutics, focusing on mechanochemical effects that can be directly integrated into biomedical applications. Additionally, the structure-functionality relationships of sonotheranostic nanoplatforms are systematically discussed, providing insights into the underlying biological effects. Finally, the limitations of current ultrasonic medicine are discussed, along with potential expansions to facilitate patient-centered translations.
Collapse
Affiliation(s)
- Biying Han
- School of Pharmacy, Nantong University, Nantong, Jiangsu Province 226001, China
| | - Yan Liu
- School of Pharmacy, Nantong University, Nantong, Jiangsu Province 226001, China
| | - Qianqian Zhou
- School of Pharmacy, Nantong University, Nantong, Jiangsu Province 226001, China
| | - Yuting Yu
- School of Pharmacy, Nantong University, Nantong, Jiangsu Province 226001, China
| | - Xingxing Liu
- School of Pharmacy, Nantong University, Nantong, Jiangsu Province 226001, China
| | - Yu Guo
- State Key Laboratory of Chemical Biology & Center of Pharmaceutics, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China
| | - Xiaohua Zheng
- School of Pharmacy, Nantong University, Nantong, Jiangsu Province 226001, China
| | - Mengjiao Zhou
- School of Pharmacy, Nantong University, Nantong, Jiangsu Province 226001, China.
| | - Haijun Yu
- State Key Laboratory of Chemical Biology & Center of Pharmaceutics, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China.
| | - Weiqi Wang
- School of Pharmacy, Nantong University, Nantong, Jiangsu Province 226001, China.
| |
Collapse
|
5
|
Lea-Banks H, Chauhan N, Hynynen K. Investigating the hypotensive effect of focused ultrasound neuromodulation and barbiturate-loaded nanodroplets in healthy and hypertensive rats. Brain Stimul 2024; 17:1317-1327. [PMID: 39643112 DOI: 10.1016/j.brs.2024.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2024] [Revised: 11/18/2024] [Accepted: 12/02/2024] [Indexed: 12/09/2024] Open
Abstract
BACKGROUND Current strategies for reducing blood pressure (BP) are ineffective and unsafe for many patient populations, including drug-resistant hypertension and during pregnancy. Stimulating the periaqueductal grey (PAG) region has shown promise in treating drug-resistant hypertension in patients using deep brain stimulation. OBJECTIVE To develop a minimally invasive neuromodulation technique for the sustained treatment of hypertension. METHODS We have investigated BP reduction using focused ultrasound (FUS) (540 kHz) and anesthetic-loaded ultrasound-responsive nanodroplets to deliver pentobarbital to the PAG in normotensive (N = 27) and hypertensive (N = 20) male and female rats. BP, heart rate and plasma hormone content were collected before and after FUS exposure, and neuronal activity was mapped in the PAG using C-Fos and neuron subtype staining. Cavitation activity was monitored by detecting acoustic emissions from vaporizing nanodroplets, and neuromodulation was verified with immunohistochemistry. RESULTS Systolic and diastolic BP were reduced for 6 h following a single sonication of the PAG (-37/-28 mmHg systolic/diastolic), and the offline effect was extended to 4 days with consecutive sonications combined with systemically injected pentobarbital-loaded nanodroplets. In contrast, FUS applied to the frontal cortex had no effect on BP. Immunohistochemistry revealed stimulation of inhibitory neurons in the PAG region, indicating that the hypotensive effect was associated with a GABAergic pathway. The acoustic emissions from vaporizing droplets were found to correlate with neuron activity and change in BP, offering the potential for real-time treatment monitoring using ultrasound. CONCLUSIONS This work has implications for developing a new treatment for hypertension that has greater safety and broader applicability for vulnerable patient populations.
Collapse
Affiliation(s)
- Harriet Lea-Banks
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Imaging, University of Toronto, Toronto, Canada.
| | - Neha Chauhan
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Canada
| |
Collapse
|
6
|
Currie AD, Wong JK, Okun MS. A review of temporal interference, nanoparticles, ultrasound, gene therapy, and designer receptors for Parkinson disease. NPJ Parkinsons Dis 2024; 10:195. [PMID: 39443513 PMCID: PMC11500395 DOI: 10.1038/s41531-024-00804-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2024] [Accepted: 09/25/2024] [Indexed: 10/25/2024] Open
Abstract
In this review, we summarize preclinical and clinical trials investigating innovative neuromodulatory approaches for Parkinson disease (PD) motor symptom management. We highlight the following technologies: temporal interference, nanoparticles for drug delivery, blood-brain barrier opening, gene therapy, optogenetics, upconversion nanoparticles, magnetothermal nanoparticles, magnetoelectric nanoparticles, ultrasound-responsive nanoparticles, and designer receptors exclusively activated by designer drugs. These studies establish the basis for novel and promising neuromodulatory treatments for PD motor symptoms.
Collapse
Affiliation(s)
- A D Currie
- Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida, Gainesville, FL, USA.
| | - J K Wong
- Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida, Gainesville, FL, USA
| | - M S Okun
- Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida, Gainesville, FL, USA
| |
Collapse
|
7
|
Jin J, Pei G, Ji Z, Liu X, Yan T, Li W, Suo D. Transcranial focused ultrasound precise neuromodulation: a review of focal size regulation, treatment efficiency and mechanisms. Front Neurosci 2024; 18:1463038. [PMID: 39301015 PMCID: PMC11410768 DOI: 10.3389/fnins.2024.1463038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2024] [Accepted: 08/23/2024] [Indexed: 09/22/2024] Open
Abstract
Ultrasound is a mechanical wave that can non-invasively penetrate the skull to deep brain regions to activate neurons. Transcranial focused ultrasound neuromodulation is a promising approach, with the advantages of noninvasiveness, high-resolution, and deep penetration, which developed rapidly over the past years. However, conventional transcranial ultrasound's spatial resolution is low-precision which hinders its use in precision neuromodulation. Here we focus on methods that could increase the spatial resolution, gain modulation efficiency at the focal spot, and potential mechanisms of ultrasound neuromodulation. In this paper, we summarize strategies to enhance the precision of ultrasound stimulation, which could potentially improve the ultrasound neuromodulation technic.
Collapse
Affiliation(s)
- Jie Jin
- School of Medical Technology, Beijing Institute of Technology, Beijing, China
| | - Guangying Pei
- School of Medical Technology, Beijing Institute of Technology, Beijing, China
| | - Zhenxiang Ji
- Advanced Research Institute of Multidisciplinary Science, Beijing Institute of Technology, Beijing, China
| | - Xinze Liu
- School of Medical Technology, Beijing Institute of Technology, Beijing, China
| | - Tianyi Yan
- School of Medical Technology, Beijing Institute of Technology, Beijing, China
| | - Wei Li
- School of Medical Technology, Beijing Institute of Technology, Beijing, China
| | - Dingjie Suo
- School of Medical Technology, Beijing Institute of Technology, Beijing, China
| |
Collapse
|
8
|
Pellow C, Pichardo S, Pike GB. A systematic review of preclinical and clinical transcranial ultrasound neuromodulation and opportunities for functional connectomics. Brain Stimul 2024; 17:734-751. [PMID: 38880207 DOI: 10.1016/j.brs.2024.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Revised: 05/21/2024] [Accepted: 06/05/2024] [Indexed: 06/18/2024] Open
Abstract
BACKGROUND Low-intensity transcranial ultrasound has surged forward as a non-invasive and disruptive tool for neuromodulation with applications in basic neuroscience research and the treatment of neurological and psychiatric conditions. OBJECTIVE To provide a comprehensive overview and update of preclinical and clinical transcranial low intensity ultrasound for neuromodulation and emphasize the emerging role of functional brain mapping to guide, better understand, and predict responses. METHODS A systematic review was conducted by searching the Web of Science and Scopus databases for studies on transcranial ultrasound neuromodulation, both in humans and animals. RESULTS 187 relevant studies were identified and reviewed, including 116 preclinical and 71 clinical reports with subjects belonging to diverse cohorts. Milestones of ultrasound neuromodulation are described within an overview of the broader landscape. General neural readouts and outcome measures are discussed, potential confounds are noted, and the emerging use of functional magnetic resonance imaging is highlighted. CONCLUSION Ultrasound neuromodulation has emerged as a powerful tool to study and treat a range of conditions and its combination with various neural readouts has significantly advanced this platform. In particular, the use of functional magnetic resonance imaging has yielded exciting inferences into ultrasound neuromodulation and has the potential to advance our understanding of brain function, neuromodulatory mechanisms, and ultimately clinical outcomes. It is anticipated that these preclinical and clinical trials are the first of many; that transcranial low intensity focused ultrasound, particularly in combination with functional magnetic resonance imaging, has the potential to enhance treatment for a spectrum of neurological conditions.
Collapse
Affiliation(s)
- Carly Pellow
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada; Hotchkiss Brain Institute, University of Calgary, Alberta, T2N 4N1, Canada.
| | - Samuel Pichardo
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada; Hotchkiss Brain Institute, University of Calgary, Alberta, T2N 4N1, Canada; Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada
| | - G Bruce Pike
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada; Hotchkiss Brain Institute, University of Calgary, Alberta, T2N 4N1, Canada; Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada
| |
Collapse
|
9
|
Wilson MG, Riis TS, Kubanek J. Controlled ultrasonic interventions through the human skull. Front Hum Neurosci 2024; 18:1412921. [PMID: 38979100 PMCID: PMC11228146 DOI: 10.3389/fnhum.2024.1412921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Accepted: 06/03/2024] [Indexed: 07/10/2024] Open
Abstract
Transcranial focused ultrasound enables precise and non-invasive manipulations of deep brain circuits in humans, promising to provide safe and effective treatments of various neurological and mental health conditions. Ultrasound focused to deep brain targets can be used to modulate neural activity directly or localize the release of psychoactive drugs. However, these applications have been impeded by a key barrier-the human skull, which attenuates ultrasound strongly and unpredictably. To address this issue, we have developed an ultrasound-based approach that directly measures and compensates for the ultrasound attenuation by the skull. No additional skull imaging, simulations, assumptions, or free parameters are necessary; the method measures the attenuation directly by emitting a pulse of ultrasound from an array on one side of the head and measuring with an array on the opposite side. Here, we apply this emerging method to two primary future uses-neuromodulation and local drug release. Specifically, we show that the correction enables effective stimulation of peripheral nerves and effective release of propofol from nanoparticle carriers through an ex vivo human skull. Neither application was effective without the correction. Moreover, the effects show the expected dose-response relationship and targeting specificity. This article highlights the need for precise control of ultrasound intensity within the skull and provides a direct and practical approach for addressing this lingering barrier.
Collapse
Affiliation(s)
- Matthew G Wilson
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
| | - Thomas S Riis
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
| | - Jan Kubanek
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
| |
Collapse
|
10
|
Wilson MG, Parikh A, Dara A, Beaver AS, Kubanek J. Targeted drug release from stable and safe ultrasound-sensitive nanocarriers. Front Mol Biosci 2024; 11:1408767. [PMID: 38962281 PMCID: PMC11219560 DOI: 10.3389/fmolb.2024.1408767] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Accepted: 05/17/2024] [Indexed: 07/05/2024] Open
Abstract
Targeted delivery of medication has the promise of increasing the effectiveness and safety of current systemic drug treatments. Focused ultrasound is emerging as noninvasive and practical energy for targeted drug release. However, it has yet to be determined which nanocarriers and ultrasound parameters can provide both effective and safe release. Perfluorocarbon nanodroplets have the potential to achieve these goals, but current approaches have either been effective or safe, but not both. We found that nanocarriers with highly stable perfluorocarbon cores mediate effective drug release so long as they are activated by ultrasound of sufficiently low frequency. We demonstrate a favorable safety profile of this formulation in a non-human primate. To facilitate translation of this approach into humans, we provide an optimized method for manufacturing the nanocarriers. This study provides a recipe and release parameters for effective and safe drug release from nanoparticle carriers in the body part specified by focused ultrasonic waves.
Collapse
Affiliation(s)
- Matthew G. Wilson
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
| | | | | | | | | |
Collapse
|
11
|
Shi J, Tan C, Ge X, Qin Z, Xiong H. Recent advances in stimuli-responsive controlled release systems for neuromodulation. J Mater Chem B 2024; 12:5769-5786. [PMID: 38804184 DOI: 10.1039/d4tb00720d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
Neuromodulation aims to modulate the signaling activity of neurons or neural networks by the precise delivery of electrical stimuli or chemical agents and is crucial for understanding brain function and treating brain disorders. Conventional approaches, such as direct physical stimulation through electrical or acoustic methods, confront challenges stemming from their invasive nature, dependency on wired power sources, and unstable therapeutic outcomes. The emergence of stimulus-responsive delivery systems harbors the potential to revolutionize neuromodulation strategies through the precise and controlled release of neurochemicals in a specific brain region. This review comprehensively examines the biological barriers controlled release systems may encounter in vivo and the recent advances and applications of these systems in neuromodulation. We elucidate the intricate interplay between the molecular structure of delivery systems and response mechanisms to furnish insights for material selection and design. Additionally, the review contemplates the prospects and challenges associated with these systems in neuromodulation. The overarching objective is to propel the application of neuromodulation technology in analyzing brain functions, treating brain disorders, and providing insightful perspectives for exploiting new systems for biomedical applications.
Collapse
Affiliation(s)
- Jielin Shi
- Key Laboratory of Mental Health of the Ministry of Education, Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Guangdong-Hong Kong Joint Laboratory for Psychiatric Disorders, Guangdong Province Key Laboratory of Psychiatric Disorders, Guangdong Basic Research Center of Excellence for Integrated Traditional and Western Medicine for Qingzhi Diseases, Department of Neurobiology, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China.
| | - Chao Tan
- Key Laboratory of Mental Health of the Ministry of Education, Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Guangdong-Hong Kong Joint Laboratory for Psychiatric Disorders, Guangdong Province Key Laboratory of Psychiatric Disorders, Guangdong Basic Research Center of Excellence for Integrated Traditional and Western Medicine for Qingzhi Diseases, Department of Neurobiology, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China.
| | - Xiaoqian Ge
- Department of Mechanical Engineering, The University of Texas at Dallas Richardson, TX 75080, USA
| | - Zhenpeng Qin
- Department of Mechanical Engineering, The University of Texas at Dallas Richardson, TX 75080, USA
- Department of Biomedical Engineering, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA
- Center for Advanced Pain Studies, The University of Texas at Dallas, Richardson, TX 75080, USA.
| | - Hejian Xiong
- Key Laboratory of Mental Health of the Ministry of Education, Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Guangdong-Hong Kong Joint Laboratory for Psychiatric Disorders, Guangdong Province Key Laboratory of Psychiatric Disorders, Guangdong Basic Research Center of Excellence for Integrated Traditional and Western Medicine for Qingzhi Diseases, Department of Neurobiology, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China.
- Department of Cardiovascular Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| |
Collapse
|
12
|
Wilson MG, Webb TD, Odéen H, Kubanek J. Remotely controlled drug release in deep brain regions of non-human primates. J Control Release 2024; 369:775-785. [PMID: 38604386 PMCID: PMC11111335 DOI: 10.1016/j.jconrel.2024.04.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 03/18/2024] [Accepted: 04/05/2024] [Indexed: 04/13/2024]
Abstract
Many areas of science and medicine would benefit from selective release of drugs in specific regions. Nanoparticle drug carriers activated by focused ultrasound-remotely applied, depth-penetrating energy-may provide such selective interventions. Here, we developed stable, ultrasound-responsive nanoparticles that can be used to release drugs effectively and safely in non-human primates. The nanoparticles were used to release propofol in deep brain visual regions. The release reversibly modulated the subjects' visual choice behavior and was specific to the targeted region and to the released drug. Gadolinium-enhanced MR imaging suggested an intact blood-brain barrier. Blood draws showed normal clinical chemistry and hematology. In summary, this study provides a safe and effective approach to release drugs on demand in selected deep brain regions at levels sufficient to modulate behavior.
Collapse
Affiliation(s)
- Matthew G Wilson
- Department of Biomedical Engineering, University of Utah, 36 S Wasatch Dr, Salt Lake City, UT 84112, USA
| | - Taylor D Webb
- Department of Biomedical Engineering, University of Utah, 36 S Wasatch Dr, Salt Lake City, UT 84112, USA
| | - Henrik Odéen
- Department of Radiology and Imaging Sciences, University of Utah, 729 Arapeen Drive, Salt Lake City, UT 84108, USA
| | - Jan Kubanek
- Department of Biomedical Engineering, University of Utah, 36 S Wasatch Dr, Salt Lake City, UT 84112, USA.
| |
Collapse
|
13
|
Zhou Q, Liu Q, Wang Y, Chen J, Schmid O, Rehberg M, Yang L. Bridging Smart Nanosystems with Clinically Relevant Models and Advanced Imaging for Precision Drug Delivery. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2308659. [PMID: 38282076 PMCID: PMC11005737 DOI: 10.1002/advs.202308659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Indexed: 01/30/2024]
Abstract
Intracellular delivery of nano-drug-carriers (NDC) to specific cells, diseased regions, or solid tumors has entered the era of precision medicine that requires systematic knowledge of nano-biological interactions from multidisciplinary perspectives. To this end, this review first provides an overview of membrane-disruption methods such as electroporation, sonoporation, photoporation, microfluidic delivery, and microinjection with the merits of high-throughput and enhanced efficiency for in vitro NDC delivery. The impact of NDC characteristics including particle size, shape, charge, hydrophobicity, and elasticity on cellular uptake are elaborated and several types of NDC systems aiming for hierarchical targeting and delivery in vivo are reviewed. Emerging in vitro or ex vivo human/animal-derived pathophysiological models are further explored and highly recommended for use in NDC studies since they might mimic in vivo delivery features and fill the translational gaps from animals to humans. The exploration of modern microscopy techniques for precise nanoparticle (NP) tracking at the cellular, organ, and organismal levels informs the tailored development of NDCs for in vivo application and clinical translation. Overall, the review integrates the latest insights into smart nanosystem engineering, physiological models, imaging-based validation tools, all directed towards enhancing the precise and efficient intracellular delivery of NDCs.
Collapse
Affiliation(s)
- Qiaoxia Zhou
- Institute of Lung Health and Immunity (LHI), Helmholtz MunichComprehensive Pneumology Center (CPC‐M)Member of the German Center for Lung Research (DZL)85764MunichGermany
- Department of Forensic PathologyWest China School of Preclinical and Forensic MedicineSichuan UniversityNo. 17 Third Renmin Road NorthChengdu610041China
- Burning Rock BiotechBuilding 6, Phase 2, Standard Industrial Unit, No. 7 LuoXuan 4th Road, International Biotech IslandGuangzhou510300China
| | - Qiongliang Liu
- Institute of Lung Health and Immunity (LHI), Helmholtz MunichComprehensive Pneumology Center (CPC‐M)Member of the German Center for Lung Research (DZL)85764MunichGermany
- Department of Thoracic SurgeryShanghai General HospitalShanghai Jiao Tong University School of MedicineShanghai200080China
| | - Yan Wang
- Qingdao Central HospitalUniversity of Health and Rehabilitation Sciences (Qingdao Central Medical Group)Qingdao266042China
| | - Jie Chen
- Department of Respiratory MedicineNational Key Clinical SpecialtyBranch of National Clinical Research Center for Respiratory DiseaseXiangya HospitalCentral South UniversityChangshaHunan410008China
- Center of Respiratory MedicineXiangya HospitalCentral South UniversityChangshaHunan410008China
- Clinical Research Center for Respiratory Diseases in Hunan ProvinceChangshaHunan410008China
- Hunan Engineering Research Center for Intelligent Diagnosis and Treatment of Respiratory DiseaseChangshaHunan410008China
- National Clinical Research Center for Geriatric DisordersXiangya HospitalChangshaHunan410008P. R. China
| | - Otmar Schmid
- Institute of Lung Health and Immunity (LHI), Helmholtz MunichComprehensive Pneumology Center (CPC‐M)Member of the German Center for Lung Research (DZL)85764MunichGermany
| | - Markus Rehberg
- Institute of Lung Health and Immunity (LHI), Helmholtz MunichComprehensive Pneumology Center (CPC‐M)Member of the German Center for Lung Research (DZL)85764MunichGermany
| | - Lin Yang
- Institute of Lung Health and Immunity (LHI), Helmholtz MunichComprehensive Pneumology Center (CPC‐M)Member of the German Center for Lung Research (DZL)85764MunichGermany
| |
Collapse
|
14
|
Wilson MG, Webb TD, Odéen H, Kubanek J. Remotely controlled drug release in deep brain regions of non-human primates. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2023.10.09.561539. [PMID: 37873134 PMCID: PMC10592699 DOI: 10.1101/2023.10.09.561539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
Abstract
Many areas of science and medicine would benefit from selective release of drugs in specific regions of interest. Nanoparticle drug carriers activated by focused ultrasound-remotely applied, depth-penetrating energy-may provide such selective interventions. Here, we developed stable, ultrasound-responsive nanoparticles that can be used to release drugs effectively and safely in non-human primates. The nanoparticles were used to release propofol in deep brain visual regions. The release reversibly modulated the subjects' visual choice behavior and was specific to the targeted region and to the released drug. Gadolinium-enhanced MRI imaging suggested an intact blood-brain barrier. Blood draws showed normal clinical chemistry and hematology. In summary, this study provides a safe and effective approach to release drugs on demand in selected deep brain regions at levels sufficient to modulate behavior.
Collapse
|
15
|
Shakya G, Cattaneo M, Guerriero G, Prasanna A, Fiorini S, Supponen O. Ultrasound-responsive microbubbles and nanodroplets: A pathway to targeted drug delivery. Adv Drug Deliv Rev 2024; 206:115178. [PMID: 38199257 DOI: 10.1016/j.addr.2023.115178] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 12/21/2023] [Accepted: 12/31/2023] [Indexed: 01/12/2024]
Abstract
Ultrasound-responsive agents have shown great potential as targeted drug delivery agents, effectively augmenting cell permeability and facilitating drug absorption. This review focuses on two specific agents, microbubbles and nanodroplets, and provides a sequential overview of their drug delivery process. Particular emphasis is given to the mechanical response of the agents under ultrasound, and the subsequent physical and biological effects on the cells. Finally, the state-of-the-art in their pre-clinical and clinical implementation are discussed. Throughout the review, major challenges that need to be overcome in order to accelerate their clinical translation are highlighted.
Collapse
Affiliation(s)
- Gazendra Shakya
- Institute of Fluid Dynamics, D-MAVT, Sonneggstrasse 3, ETH Zurich, Zurich, 8092, Switzerland
| | - Marco Cattaneo
- Institute of Fluid Dynamics, D-MAVT, Sonneggstrasse 3, ETH Zurich, Zurich, 8092, Switzerland
| | - Giulia Guerriero
- Institute of Fluid Dynamics, D-MAVT, Sonneggstrasse 3, ETH Zurich, Zurich, 8092, Switzerland
| | - Anunay Prasanna
- Institute of Fluid Dynamics, D-MAVT, Sonneggstrasse 3, ETH Zurich, Zurich, 8092, Switzerland
| | - Samuele Fiorini
- Institute of Fluid Dynamics, D-MAVT, Sonneggstrasse 3, ETH Zurich, Zurich, 8092, Switzerland
| | - Outi Supponen
- Institute of Fluid Dynamics, D-MAVT, Sonneggstrasse 3, ETH Zurich, Zurich, 8092, Switzerland.
| |
Collapse
|
16
|
Woodward A, Mattrey RF, de Gracia Lux C. Direct Emulsification of Stable Superheated Perfluorobutane Nanodroplets by Sonication: Addressing the Limitations of the Microbubble Condensation Technique. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:445-452. [PMID: 38171955 DOI: 10.1016/j.ultrasmedbio.2023.12.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 10/18/2023] [Accepted: 12/05/2023] [Indexed: 01/05/2024]
Abstract
OBJECTIVE We have previously determined that direct formulation of a phospholipid-based perfluorobutane (PFB) emulsion using high-pressure homogenization produces monodispersed PFB nanodroplets (NDs) with relatively few non-PFB-filled NDs. In this article, we describe a simpler strategy to reproducibly formulate highly concentrated superheated PFB NDs using a probe sonicator, a more widely available tool. METHODS Similar to the homogenization technique, sonicating at low power a solution of phospholipids with condensed PFB at -10°C consistently yields NDs with an encapsulation efficiency close to 100% and very few non-PFB-filled particles. RESULTS The PFB emulsion is stable with absence of spontaneous vaporization at 37°C and for more than 14 d when frozen or refrigerated and for 3 d at 25°C. Acoustic droplet vaporization (ADV) occurred at a mechanical index >0.5 and continued to increase thereafter. The ADV threshold was similar for freshly made or frozen emulsion after thawing. In contrast to the microbubble (MB) condensation method, in which the ratio of non-PFB-filled to PFB-filled is 2000:1, particularly if MBs are not washed after formulation, nearly 94% of particles produced by direct sonication are PFB filled. CONCLUSION PFB NDs can be manufactured with high yield, stability and reproducibility using a probe sonicator that is available in many laboratories. Their ease of manufacture could spark discoveries into highly impactful ND-based diagnostic and therapeutic applications.
Collapse
Affiliation(s)
- Adam Woodward
- Department of Radiology, Translational Research in Ultrasound Theranostics (TRUST) Program, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Robert F Mattrey
- Department of Radiology, Translational Research in Ultrasound Theranostics (TRUST) Program, University of Texas Southwestern Medical Center, Dallas, TX, USA; Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Caroline de Gracia Lux
- Department of Radiology, Translational Research in Ultrasound Theranostics (TRUST) Program, University of Texas Southwestern Medical Center, Dallas, TX, USA; Biomedical Engineering Graduate Program, University of Texas Southwestern Medical Center, Dallas, TX, USA.
| |
Collapse
|
17
|
Jiao H, Mao Q, Razzaq N, Ankri R, Cui J. Ultrasound technology assisted colloidal nanocrystal synthesis and biomedical applications. ULTRASONICS SONOCHEMISTRY 2024; 103:106798. [PMID: 38330546 PMCID: PMC10865478 DOI: 10.1016/j.ultsonch.2024.106798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 12/08/2023] [Accepted: 02/01/2024] [Indexed: 02/10/2024]
Abstract
Non-invasive and high spatiotemporal resolution mythologies for the diagnosis and treatment of disease in clinical medicine promote the development of modern medicine. Ultrasound (US) technology provides a non-invasive, real-time, and cost-effective clinical imaging modality, which plays a significant role in chemical synthesis and clinical translation, especially in in vivo imaging and cancer therapy. On the one hand, the US treatment is usually accompanied by cavitation, leading to high temperature and pressure, so-called "hot spot", playing a significant role in sonochemical-based colloidal synthesis. Compared with the classical nucleation synthetic method, the sonochemical synthesis strategy presents high efficiency for the fabrication of colloidal nanocrystals due to its fast nucleation and growth procedure. On the other hand, the US is attractive for in vivo and medical treatment, with applications increasing with the development of novel contrast agents, such as the micro and nano bubbles, which are widely used in neuromodulation, with which the US can breach the blood-brain barrier temporarily and safely, opening a new door to neuromodulation and therapy. In terms of cancer treatment, sonodynamic therapy and US-assisted synergetic therapy show great effects against cancer and sonodynamic immunotherapy present unparalleled potentiality compared with other synergetic therapies. Further development of ultrasound technology can revolutionize both chemical synthesis and clinical translation by improving efficiency, precision, and accessibility while reducing environmental impact and enhancing patient care. In this paper, we review the US-assisted sonochemical synthesis and biological applications, to promote the next generation US technology-assisted applications.
Collapse
Affiliation(s)
- Haorong Jiao
- The Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, 199 Renai Road, Industrial Park, Suzhou 215123, Jiangsu, China
| | - Qiulian Mao
- The Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, 199 Renai Road, Industrial Park, Suzhou 215123, Jiangsu, China
| | - Noman Razzaq
- The Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, 199 Renai Road, Industrial Park, Suzhou 215123, Jiangsu, China
| | - Rinat Ankri
- The Biomolecular and Nanophotonics Lab, Ariel University, 407000, P.O.B. 3, Ariel, Israel.
| | - Jiabin Cui
- The Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, 199 Renai Road, Industrial Park, Suzhou 215123, Jiangsu, China.
| |
Collapse
|
18
|
Riis T, Feldman D, Mickey B, Kubanek J. Controlled noninvasive modulation of deep brain regions in humans. COMMUNICATIONS ENGINEERING 2024; 3:13. [PMCID: PMC10956068 DOI: 10.1038/s44172-023-00146-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Accepted: 11/29/2023] [Indexed: 10/06/2024]
Abstract
Transcranial focused ultrasound provides noninvasive and reversible approaches for precise and personalized manipulations of brain circuits, with the potential to transform our understanding of brain function and treatments of brain dysfunction. However, effective applications in humans have been limited by the human head, which attenuates and distorts ultrasound severely and unpredictably. This has led to uncertain ultrasound intensities delivered into the brain. Here, we address this lingering barrier using a direct measurement approach that can be repeatedly applied to the human brain. The approach uses an ultrasonic scan of the head to measure and compensate for the attenuation of the ultrasound by all obstacles within the ultrasound path. No other imaging modality is required and the method is parameter-free and personalized to each subject. The approach accurately restores operators’ intended intensities inside ex-vivo human skulls. Moreover, the approach is critical for effective modulation of deep brain regions in humans. When applied, the approach modulates fMRI Blood Oxygen Level Dependent (BOLD) activity in disease-relevant deep brain regions. This tool unlocks the potential of emerging approaches based on low-intensity ultrasound for controlled manipulations of neural circuits in humans. Transcranial focused ultrasound has had limited applications in humans due to the unpredictable distortions of ultrasound by the human head. Thomas Riis and colleagues report an approach which enables direct correction for the attenuation of ultrasound by the skull and hair, thus enabling controlled ultrasound therapies in humans.
Collapse
Affiliation(s)
- Thomas Riis
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84102 USA
| | - Daniel Feldman
- Department of Psychiatry, University of Utah, Salt Lake City, UT 84102 USA
| | - Brian Mickey
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84102 USA
- Department of Psychiatry, University of Utah, Salt Lake City, UT 84102 USA
| | - Jan Kubanek
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84102 USA
| |
Collapse
|
19
|
Pellow C, Jafari Sojahrood A, Zhao X, Kolios MC, Exner AA, Goertz DE. Synchronous Intravital Imaging and Cavitation Monitoring of Antivascular Focused Ultrasound in Tumor Microvasculature Using Monodisperse Low Boiling Point Nanodroplets. ACS NANO 2024; 18:410-427. [PMID: 38147452 PMCID: PMC10786165 DOI: 10.1021/acsnano.3c07711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 12/18/2023] [Accepted: 12/20/2023] [Indexed: 12/28/2023]
Abstract
Focused ultrasound-stimulated microbubbles can induce blood flow shutdown and ischemic necrosis at higher pressures in an approach termed antivascular ultrasound. Combined with conventional therapies of chemotherapy, immunotherapy, and radiation therapy, this approach has demonstrated tumor growth inhibition and profound synergistic antitumor effects. However, the lower cavitation threshold of microbubbles can potentially yield off-target damage that the polydispersity of clinical agent may further exacerbate. Here we investigate the use of a monodisperse nanodroplet formulation for achieving antivascular effects in tumors. We first develop stable low boiling point monodisperse lipid nanodroplets and examine them as an alternative agent to mediate antivascular ultrasound. With synchronous intravital imaging and ultrasound monitoring of focused ultrasound-stimulated nanodroplets in tumor microvasculature, we show that nanodroplets can trigger blood flow shutdown and do so with a sharper pressure threshold and with fewer additional events than conventionally used microbubbles. We further leverage the smaller size and prolonged pharmacokinetic profile of nanodroplets to allow for potential passive accumulation in tumor tissue prior to antivascular ultrasound, which may be a means by which to promote selective tumor targeting. We find that vascular shutdown is accompanied by inertial cavitation and complex-order sub- and ultraharmonic acoustic signatures, presenting an opportunity for effective feedback control of antivascular ultrasound.
Collapse
Affiliation(s)
- Carly Pellow
- Sunnybrook
Research Institute, Toronto M4N 3M5, Canada
| | - Amin Jafari Sojahrood
- Sunnybrook
Research Institute, Toronto M4N 3M5, Canada
- Department
of Physics, Toronto Metropolitan University, Toronto M5B 2K3, Canada
- Institute
for Biomedical Engineering, Science and Technology (iBEST), a partnership
between St. Michael’s Hospital, a site of Unity Health Toronto
and Toronto Metropolitan University, Toronto M5B 1T8, Canada
| | - Xiaoxiao Zhao
- Sunnybrook
Research Institute, Toronto M4N 3M5, Canada
- Department
of Medical Biophysics, University of Toronto, Toronto M5G 1L7, Canada
| | - Michael C. Kolios
- Department
of Physics, Toronto Metropolitan University, Toronto M5B 2K3, Canada
- Institute
for Biomedical Engineering, Science and Technology (iBEST), a partnership
between St. Michael’s Hospital, a site of Unity Health Toronto
and Toronto Metropolitan University, Toronto M5B 1T8, Canada
| | - Agata A. Exner
- Department
of Radiology, Case Western Reserve University, Cleveland, Ohio 44106, United States
| | - David E. Goertz
- Sunnybrook
Research Institute, Toronto M4N 3M5, Canada
- Department
of Medical Biophysics, University of Toronto, Toronto M5G 1L7, Canada
| |
Collapse
|
20
|
Wang M, Xu T, Li D, Wu Y, Zhang B, Zhang S. Enhanced and spatially controllable neuronal activity induced by transcranial focused ultrasound stimulation combined with phase-change nanodroplets. ULTRASONICS SONOCHEMISTRY 2023; 101:106686. [PMID: 37956511 PMCID: PMC10661601 DOI: 10.1016/j.ultsonch.2023.106686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 11/04/2023] [Accepted: 11/05/2023] [Indexed: 11/15/2023]
Abstract
Non-invasive ultrasound neuromodulation (USNM) is a powerful tool to explore neural circuits and treat neurological disorders. Due to the heterogeneity of the skull and regional variations in modulation and treatment objectives, it is necessary to develop an efficient and spatially controllable neuromodulation approach. Recently, transcranial focused ultrasound (tFUS) combined with external biomicro/nanomaterials for brain stimulation has garnered significant attention. This study focused on tFUS combined with perfluoropentane (PFP) nanodroplets (NDs) to improve the efficacy and spatial controllability of USNM. The developed two-stage variable pulse tFUS sequence that include the acoustic droplet vaporization (ADV) pulse for vaporizing PFP NDs into microbubbles (MBs) and the USNM sequence for inducing mechanical oscillations of the formed MBs to enhance neuronal activity. Further, adjusting the acoustic pressure of the ADV pulse generated the controllable vaporization regions, thereby achieving spatially controllable neuromodulation. The results showed that the mean densities of c-fos+ cells expression in the group of PFP NDs with ADV (109 ± 19 cells/mm2) were significantly higher compared to the group without ADV (37.34 ± 8.24 cells/mm2). The acoustic pressure of the ADV pulse with 1.98 MPa and 2.81 MPa in vitro generated the vaporization regions of 0.146 ± 0.032 cm2 and 0.349 ± 0.056 cm2, respectively. Under the same stimulation conditions, a larger vaporization region was also obtained with higher acoustic pressure in vivo, inducing a broader region of neuronal activation. Therefore, this study will serve as a valuable reference for developing the efficient and spatially controllable tFUS neuromodulation strategy.
Collapse
Affiliation(s)
- Mengke Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Tianqi Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Dapeng Li
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Yue Wu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Baochen Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Siyuan Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.
| |
Collapse
|
21
|
Purohit MP, Roy KS, Xiang Y, Yu BJ, Azadian MM, Muwanga G, Hart AR, Taoube AK, Lopez DG, Airan RD. Acoustomechanically activatable liposomes for ultrasonic drug uncaging. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.10.23.563690. [PMID: 37961368 PMCID: PMC10634775 DOI: 10.1101/2023.10.23.563690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2023]
Abstract
Ultrasound-activatable drug-loaded nanocarriers enable noninvasive and spatiotemporally-precise on-demand drug delivery throughout the body. However, most systems for ultrasonic drug uncaging utilize cavitation or heating as the drug release mechanism and often incorporate relatively exotic excipients into the formulation that together limit the drug-loading potential, stability, and clinical translatability and applicability of these systems. Here we describe an alternate strategy for the design of such systems in which the acoustic impedance and osmolarity of the internal liquid phase of a drug-loaded particle is tuned to maximize ultrasound-induced drug release. No gas phase, cavitation, or medium heating is necessary for the drug release mechanism. Instead, a non-cavitation-based mechanical response to ultrasound mediates the drug release. Importantly, this strategy can be implemented with relatively common pharmaceutical excipients, as we demonstrate here by implementing this mechanism with the inclusion of a few percent sucrose into the internal buffer of a liposome. Further, the ultrasound protocols sufficient for in vivo drug uncaging with this system are achievable with current clinical therapeutic ultrasound systems and with intensities that are within FDA and society guidelines for safe transcranial ultrasound application. Finally, this current implementation of this mechanism should be versatile and effective for the loading and uncaging of any therapeutic that may be loaded into a liposome, as we demonstrate for four different drugs in vitro, and two in vivo. These acoustomechanically activatable liposomes formulated with common pharmaceutical excipients promise a system with high clinical translational potential for ultrasonic drug uncaging of myriad drugs of clinical interest.
Collapse
Affiliation(s)
| | - Kanchan Sinha Roy
- Department of Radiology, Stanford University, Stanford, CA, 94305 USA
| | - Yun Xiang
- Department of Radiology, Stanford University, Stanford, CA, 94305 USA
| | - Brenda J. Yu
- Department of Radiology, Stanford University, Stanford, CA, 94305 USA
- Biophysics Program, Stanford University, Stanford, CA, 94305 USA
| | - Matine M. Azadian
- Department of Radiology, Stanford University, Stanford, CA, 94305 USA
- Neurosciences Program, Stanford University, Stanford, CA, 94305 USA
| | - Gabriella Muwanga
- Department of Radiology, Stanford University, Stanford, CA, 94305 USA
- Neurosciences Program, Stanford University, Stanford, CA, 94305 USA
| | - Alex R. Hart
- Department of Radiology, Stanford University, Stanford, CA, 94305 USA
- Department of Chemistry, Stanford University, Stanford, CA, 94305 USA
| | - Ali K. Taoube
- Department of Radiology, Stanford University, Stanford, CA, 94305 USA
| | - Diego Gomez Lopez
- Department of Radiology, Stanford University, Stanford, CA, 94305 USA
- Department of Medicine, Health, and Society, Vanderbilt University, Nashville, TN 37235 USA
| | - Raag D. Airan
- Department of Radiology, Stanford University, Stanford, CA, 94305 USA
- Department of Psychiatry and Behavioral Sciences, Stanford University, Stanford, CA, 94305 USA
- Department of Materials Science and Engineering, Stanford University, Stanford, CA, 94305 USA
| |
Collapse
|
22
|
Zhang G, Liao C, Hu JR, Hu HM, Lei YM, Harput S, Ye HR. Nanodroplet-Based Super-Resolution Ultrasound Localization Microscopy. ACS Sens 2023; 8:3294-3306. [PMID: 37607403 DOI: 10.1021/acssensors.3c00418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
Over the past decade, super-resolution ultrasound localization microscopy (SR-ULM) has revolutionized ultrasound imaging with its capability to resolve the microvascular structures below the ultrasound diffraction limit. The introduction of this imaging technique enables the visualization, quantification, and characterization of tissue microvasculature. The early implementations of SR-ULM utilize microbubbles (MBs) that require a long image acquisition time due to the requirement of capturing sparsely isolated microbubble signals. The next-generation SR-ULM employs nanodroplets that have the potential to significantly reduce the image acquisition time without sacrificing the resolution. This review discusses various nanodroplet-based ultrasound localization microscopy techniques and their corresponding imaging mechanisms. A summary is given on the preclinical applications of SR-ULM with nanodroplets, and the challenges in the clinical translation of nanodroplet-based SR-ULM are presented while discussing the future perspectives. In conclusion, ultrasound localization microscopy is a promising microvasculature imaging technology that can provide new diagnostic and prognostic information for a wide range of pathologies, such as cancer, heart conditions, and autoimmune diseases, and enable personalized treatment monitoring at a microlevel.
Collapse
Affiliation(s)
- Ge Zhang
- Department of Medical Ultrasound, China Resources & Wisco General Hospital, Wuhan University of Science and Technology, Wuhan 430080, People's Republic of China
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, Wuhan University of Science and Technology, Wuhan 430065, People's Republic of China
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, PSL University, CNRS, Paris 75015, France
| | - Chen Liao
- Department of Medical Ultrasound, China Resources & Wisco General Hospital, Wuhan University of Science and Technology, Wuhan 430080, People's Republic of China
- Medical College, Wuhan University of Science and Technology, Wuhan 430065, People's Republic of China
| | - Jun-Rui Hu
- Department of Pharmacy, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, People's Republic of China
| | - Hai-Man Hu
- Department of Electrical and Electronic Engineering, Hubei University of Technology, Wuhan 430068, People's Republic of China
| | - Yu-Meng Lei
- Department of Medical Ultrasound, China Resources & Wisco General Hospital, Wuhan University of Science and Technology, Wuhan 430080, People's Republic of China
| | - Sevan Harput
- Department of Electrical and Electronic Engineering, London South Bank University, London SE1 0AA, U.K
| | - Hua-Rong Ye
- Department of Medical Ultrasound, China Resources & Wisco General Hospital, Wuhan University of Science and Technology, Wuhan 430080, People's Republic of China
| |
Collapse
|
23
|
Wen Z, Liu C, Teng Z, Jin Q, Liao Z, Zhu X, Huo S. Ultrasound meets the cell membrane: for enhanced endocytosis and drug delivery. NANOSCALE 2023; 15:13532-13545. [PMID: 37548587 DOI: 10.1039/d3nr02562d] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/08/2023]
Abstract
Endocytosis plays a crucial role in drug delivery for precision therapy. As a non-invasive and spatiotemporal-controllable stimulus, ultrasound (US) has been utilized for improving drug delivery efficiency due to its ability to enhance cell membrane permeability. When US meets the cell membrane, the well-known cavitation effect generated by US can cause various biophysical effects, facilitating the delivery of various cargoes, especially nanocarriers. The comprehension of recent progress in the biophysical mechanism governing the interaction between ultrasound and cell membranes holds significant implications for the broader scientific community, particularly in drug delivery and nanomedicine. This review will summarize the latest research results on the biological effects and mechanisms of US-enhanced cellular endocytosis. Moreover, the latest achievements in US-related biomedical applications will be discussed. Finally, challenges and opportunities of US-enhanced endocytosis for biomedical applications will be provided.
Collapse
Affiliation(s)
- Zihao Wen
- Fujian Provincial Key Laboratory of Innovative Drug Target Research, School of Pharmaceutical Sciences, Xiamen University, Xiamen 361102, China.
| | - Chen Liu
- Fujian Provincial Key Laboratory of Innovative Drug Target Research, School of Pharmaceutical Sciences, Xiamen University, Xiamen 361102, China.
| | - Zihao Teng
- Fujian Provincial Key Laboratory of Innovative Drug Target Research, School of Pharmaceutical Sciences, Xiamen University, Xiamen 361102, China.
| | - Quanyi Jin
- Fujian Provincial Key Laboratory of Innovative Drug Target Research, School of Pharmaceutical Sciences, Xiamen University, Xiamen 361102, China.
| | - Zhihuan Liao
- Fujian Provincial Key Laboratory of Innovative Drug Target Research, School of Pharmaceutical Sciences, Xiamen University, Xiamen 361102, China.
| | - Xuan Zhu
- Fujian Provincial Key Laboratory of Innovative Drug Target Research, School of Pharmaceutical Sciences, Xiamen University, Xiamen 361102, China.
| | - Shuaidong Huo
- Fujian Provincial Key Laboratory of Innovative Drug Target Research, School of Pharmaceutical Sciences, Xiamen University, Xiamen 361102, China.
| |
Collapse
|
24
|
Ting SG, Lea-Banks H, Hynynen K. Physical Characterization to Improve Scalability and Potential of Anesthetic-Loaded Nanodroplets. Pharmaceutics 2023; 15:2077. [PMID: 37631291 PMCID: PMC10457791 DOI: 10.3390/pharmaceutics15082077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Revised: 07/21/2023] [Accepted: 08/01/2023] [Indexed: 08/27/2023] Open
Abstract
Drug-loaded perfluorocarbon nanodroplets (NDs) can be activated non-invasively by focused ultrasound (FUS) and allow for precise drug-delivery. Anesthetic-loaded NDs and transcranial FUS have previously achieved targeted neuromodulation. To assess the clinical potential of anesthetic-loaded NDs, in depth physical characterization and investigation of storage strategies and triggered-activation is necessary. Pentobarbital-loaded decafluorobutane nanodroplets (PBNDs) with a Definity-derived lipid shell (237 nm; 4.08 × 109 particles/mL) were fabricated and assessed. Change in droplet stability, concentration, and drug-release efficacy were tested for PBNDs frozen at -80 °C over 4 weeks. PBND diameter and the polydispersity index of thawed droplets remained consistent up to 14 days frozen. Cryo-TEM images revealed NDs begin to lose circularity at 7 days, and by 14 days, perfluorocarbon dissolution and lipid fragmentation occurred. The level of acoustic response and drug release decreases through prolonged storage. PBNDs showed no hemolytic activity at clinically relevant concentrations and conditions. At increasing sonication pressures, liquid PBNDs vaporized into gas microbubbles, and acoustic activity at the second harmonic frequency (2 f0) peaked at lower pressures than the subharmonic frequency (1/2 f0). Definity-based PBNDs have been thoroughly characterized, cryo-TEM has been shown to be suitable to image the internal structure of volatile NDs, and PBNDs can be reliably stored at -80 °C for future use up to 7 days without significant degradation, loss of acoustic response, or reduction in ultrasound-triggered drug release.
Collapse
Affiliation(s)
- Siulam Ginni Ting
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada;
- Department of Medical Biophysics, University of Toronto, Toronto, ON M5S 1A1, Canada
| | - Harriet Lea-Banks
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada;
| | - Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada;
- Department of Medical Biophysics, University of Toronto, Toronto, ON M5S 1A1, Canada
- Institute of Biomedical Imaging, University of Toronto, Toronto, ON M5S 1A1, Canada
| |
Collapse
|
25
|
Gouveia FV, Lea‐Banks H, Aubert I, Lipsman N, Hynynen K, Hamani C. Anesthetic-loaded nanodroplets with focused ultrasound reduces agitation in Alzheimer's mice. Ann Clin Transl Neurol 2023; 10:507-519. [PMID: 36715553 PMCID: PMC10109287 DOI: 10.1002/acn3.51737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 01/03/2023] [Accepted: 01/16/2023] [Indexed: 01/31/2023] Open
Abstract
OBJECTIVE Alzheimer's disease (AD) is often associated with neuropsychiatric symptoms, including agitation and aggressive behavior. These symptoms increase with disease severity, ranging from 10% in mild cognitive impairment to 50% in patients with moderate-to-severe AD, pose a great risk for self-injury and injury to caregivers, result in high rates of institutionalization and great suffering for patients and families. Current pharmacological therapies have limited efficacy and a high potential for severe side effects. Thus, there is a growing need to develop novel therapeutics tailored to safely and effectively reduce agitation and aggressive behavior in AD. Here, we investigate for the first time the use of focused ultrasound combined with anesthetic-loaded nanodroplets (nanoFUS) targeting the amygdala (key structure in the neurocircuitry of agitation) as a novel minimally invasive tool to modulate local neural activity and reduce agitation and aggressive behavior in the TgCRND8 AD transgenic mice. METHODS Male and female animals were tested in the resident-intruder (i.e., aggressive behavior) and open-field tests (i.e., motor agitation) for baseline measures, followed by treatment with active- or sham-nanoFUS. Behavioral testing was then repeated after treatment. RESULTS Active-nanoFUS neuromodulation reduced aggressive behavior and agitation in male mice, as compared to sham-treated controls. Treatment with active-nanoFUS increased the time male mice spent in social-non-aggressive behaviors. INTERPRETATION Our results show that neuromodulation with active-nanoFUS may be a potential therapeutic tool for the treatment of neuropsychiatric symptoms, with special focus on agitation and aggressive behaviors. Further studies are necessary to establish cellular, molecular and long-term behavioral changes following treatment with nanoFUS.
Collapse
Affiliation(s)
- Flavia Venetucci Gouveia
- Biological Sciences PlatformSunnybrook Research InstituteTorontoOntarioM4N 3M5Canada
- Neurosciences and Mental HealthThe Hospital for Sick ChildrenTorontoOntarioM5G 1X8Canada
| | - Harriet Lea‐Banks
- Physical Sciences PlatformSunnybrook Research InstituteTorontoOntarioM4N 3M5Canada
| | - Isabelle Aubert
- Biological Sciences PlatformSunnybrook Research InstituteTorontoOntarioM4N 3M5Canada
- Laboratory Medicine & PathobiologyUniversity of TorontoTorontoOntarioM5S 1A1Canada
- Hurvitz Brain Sciences Program, Sunnybrook Health Sciences CentreTorontoOntarioM4N 3M5Canada
| | - Nir Lipsman
- Biological Sciences PlatformSunnybrook Research InstituteTorontoOntarioM4N 3M5Canada
- Hurvitz Brain Sciences Program, Sunnybrook Health Sciences CentreTorontoOntarioM4N 3M5Canada
- Harquail Centre for Neuromodulation, Sunnybrook Health Sciences CentreTorontoOntarioM4N 3M5Canada
- Division of NeurosurgeryUniversity of TorontoTorontoOntarioM5T 1P5Canada
| | - Kullervo Hynynen
- Physical Sciences PlatformSunnybrook Research InstituteTorontoOntarioM4N 3M5Canada
- Hurvitz Brain Sciences Program, Sunnybrook Health Sciences CentreTorontoOntarioM4N 3M5Canada
- Department of Medical BiophysicsUniversity of TorontoTorontoOntarioM5S 1A1Canada
- Institute of Biomedical Engineering, University of TorontoTorontoOntarioM5S 1A1Canada
| | - Clement Hamani
- Biological Sciences PlatformSunnybrook Research InstituteTorontoOntarioM4N 3M5Canada
- Hurvitz Brain Sciences Program, Sunnybrook Health Sciences CentreTorontoOntarioM4N 3M5Canada
- Harquail Centre for Neuromodulation, Sunnybrook Health Sciences CentreTorontoOntarioM4N 3M5Canada
- Division of NeurosurgeryUniversity of TorontoTorontoOntarioM5T 1P5Canada
| |
Collapse
|
26
|
Samani RK, Maghsoudinia F, Mehradnia F, Hejazi SH, Saeb M, Sobhani T, Farahbakhsh Z, Mehrgardi MA, Tavakoli MB. Ultrasound-guided chemoradiotherapy of breast cancer using smart methotrexate-loaded perfluorohexane nanodroplets. NANOMEDICINE : NANOTECHNOLOGY, BIOLOGY, AND MEDICINE 2023; 48:102643. [PMID: 36584739 DOI: 10.1016/j.nano.2022.102643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 12/01/2022] [Accepted: 12/04/2022] [Indexed: 12/29/2022]
Abstract
Chemoradiotherapy with controlled-release nanocarriers such as sono-sensitive nanodroplets (NDs) can enhance the anticancer activity of chemotherapy medicines and reduces normal tissue side effects. In this study, folic acid-functionalized methotrexate-loaded perfluorohexane NDs with alginate shell (FA-MTX/PFH@alginate NDs) were synthesized, characterized, and their potential for ultrasound-guided chemoradiotherapy of breast cancer was investigated in vitro and in vivo. The cancer cell (4T1) viabilities and surviving fractions after NDs and ultrasound treatments were significantly decreased. However, this reduction was much more significant for ultrasound in combination with X-ray irradiation. The in vitro and in vivo results confirmed that MTX-loaded NDs are highly biocompatible and they have no significant hemolytic activity and organ toxicity. Furthermore, the in vivo results indicated that the FA-MTX/PFH@alginate NDs were accumulated selectively in the tumor region. In conclusion, FA-functionalized MTX/PFH@alginate NDs have a great theranostic performance for ultrasound-controlled drug delivery in combination with radiotherapy of breast cancer.
Collapse
Affiliation(s)
- Roghayeh Kamran Samani
- Department of Medical Physics and Radiology, School of Allied Medical Sciences, Shahrekord University of Medical Sciences, Shahrekord, Iran; Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan 81746-73461, Iran
| | - Fatemeh Maghsoudinia
- Department of Medical Imaging and Radiation Sciences, Faculty of Paramedicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Fatemeh Mehradnia
- Division of Molecular Therapeutics and Formulation, School of Pharmacy, University of Nottingham, NG7 2RD, UK
| | - Seyed Hossein Hejazi
- Skin Diseases and Leishmaniasis Research Center, Department of Parasitology and Mycology, School of Medicine, Isfahan University of Medical Sciences, Isfahan 81746-73461, Iran
| | - Mohsen Saeb
- Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan 81746-73461, Iran
| | - Tayebe Sobhani
- Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan 81746-73461, Iran
| | - Zohreh Farahbakhsh
- Department of Medical Parasitology and Mycology, Faculty of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Masoud A Mehrgardi
- Department of Chemistry, University of Isfahan, Isfahan 81746-73441, Iran.
| | - Mohamad Bagher Tavakoli
- Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan 81746-73461, Iran.
| |
Collapse
|
27
|
Xu M, Long W, Ling X, Hu X, Hong H, Peng Y, Cai T. Multifunctional theragnostic ultrasmall gold nanodot-encapsuled perfluorocarbon nanodroplets for laser-focused ultrasound sequence irradiation (LFSI)-based enhanced tumor ablation. J Mater Chem B 2022; 10:9816-9829. [PMID: 36426923 DOI: 10.1039/d2tb01775j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Despite the substantial potential of focused ultrasound therapy, its efficacy in cancer therapy has been limited due to the high cavitation threshold and safety concerns regarding the use of high-intensity energy pulses. Here, ultrasmall Au nanodot-loaded PEG-modified perfluorocarbon nanodroplets (Au-PFCnDs) were prepared and used as a therapeutic enhancer. A LFSI method was designed to achieve enhanced tumor ablation at a mild focused ultrasound (FUS) energy pulse with the assistance of the instinct photothermal effect of intratumor-permeable ultrasmall Au nanodots under 808 nm NIR laser irradiation. In addition to their therapeutic function, Au-PFCnDs can also generate multimodal images to provide information for tumor surveillance and treatment guidance. The experimental results also showed that the cRGD-targeted Au-PFCnDs could be more efficiently delivered into the tumor and selectively destroy tumors with no observable side effects on normal tissue under LFSI treatment.
Collapse
Affiliation(s)
- Menghan Xu
- State Key Laboratory of Natural Medicines, Department of Pharmaceutics, China Pharmaceutical University, Nanjing 210009, China.
| | - Wei Long
- State Key Laboratory of Natural Medicines, Department of Pharmaceutics, China Pharmaceutical University, Nanjing 210009, China.
| | - Xiang Ling
- State Key Laboratory of Natural Medicines, Department of Pharmaceutics, China Pharmaceutical University, Nanjing 210009, China.
| | - Xiongwei Hu
- State Key Laboratory of Natural Medicines, Department of Pharmaceutics, China Pharmaceutical University, Nanjing 210009, China.
| | - Hao Hong
- State Key Laboratory of Pharmaceutical Biotechnology, Jiangsu Key Laboratory of Molecular Medicine and School of Medicine, Medical School of Nanjing University, Nanjing 210093, China
| | - Yayun Peng
- State Key Laboratory of Natural Medicines, Department of Pharmaceutics, China Pharmaceutical University, Nanjing 210009, China.
| | - Ting Cai
- State Key Laboratory of Natural Medicines, Department of Pharmaceutics, China Pharmaceutical University, Nanjing 210009, China.
| |
Collapse
|
28
|
Lea-Banks H, Wu SK, Lee H, Hynynen K. Ultrasound-triggered oxygen-loaded nanodroplets enhance and monitor cerebral damage from sonodynamic therapy. Nanotheranostics 2022; 6:376-387. [PMID: 35795341 PMCID: PMC9254362 DOI: 10.7150/ntno.71946] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 06/03/2022] [Indexed: 11/05/2022] Open
Abstract
In sonodynamic therapy, cellular toxicity from sonosensitizer drugs, such as 5-aminolevulinic acid hydrochloride (5-ALA), may be triggered with focused ultrasound through the production of reactive oxygen species (ROS). Here we show that by increasing local oxygen during treatment, using oxygen-loaded perfluorocarbon nanodroplets (250 +/- 8 nm), we can increase the damage induced by 5-ALA, and monitor the severity by recording acoustic emissions in the brain. To achieve this, we sonicated the right striatum of 16 healthy rats after an intravenous dose of 5-ALA (200 mg/kg), followed by saline, nanodroplets, or oxygen-loaded nanodroplets. We assessed haemorrhage, edema and cell apoptosis immediately following, 24 hr, and 48 hr after focused ultrasound treatment. The localized volume of damaged tissue was significantly enhanced by the presence of oxygen-loaded nanodroplets, compared to ultrasound with unloaded nanodroplets (3-fold increase), and ultrasound alone (40-fold increase). Sonicating 1 hr following 5-ALA injection was found to be more potent than 2 hr following 5-ALA injection (2-fold increase), and the severity of tissue damage corresponded to the acoustic emissions from droplet vaporization. Enhancing the local damage from 5-ALA with monitored cavitation activity and additional oxygen could have significant implications in the treatment of atherosclerosis and non-invasive ablative surgeries.
Collapse
Affiliation(s)
- Harriet Lea-Banks
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Sheng-Kai Wu
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada.,Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - Hannah Lee
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada.,Department of Medical Biophysics, University of Toronto, Toronto, Canada.,Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
| |
Collapse
|
29
|
Zhang S, Zhang S, Luo S, Tang P, Wan M, Wu D, Gao W. Ultrasound-assisted brain delivery of nanomedicines for brain tumor therapy: advance and prospect. J Nanobiotechnology 2022; 20:287. [PMID: 35710426 PMCID: PMC9205090 DOI: 10.1186/s12951-022-01464-z] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 05/18/2022] [Indexed: 12/14/2022] Open
Abstract
Nowadays, brain tumors are challenging problems, and the key of therapy is ensuring therapeutic drugs cross the blood-brain barrier (BBB) effectively. Although the efficiency of drug transport across the BBB can be increased by innovating and modifying nanomedicines, they exert insufficient therapeutic effects on brain tumors due to the complex environment of the brain. It is worth noting that ultrasound combined with the cavitation effect of microbubbles can assist BBB opening and enhance brain delivery of nanomedicines. This ultrasound-assisted brain delivery (UABD) technology with related nanomedicines (UABD nanomedicines) can safely open the BBB, facilitate the entry of drugs into the brain, and enhance the therapeutic effect on brain tumors. UABD nanomedicines, as the main component of UABD technology, have great potential in clinical application and have been an important area of interest in the field of brain tumor therapy. However, research on UABD nanomedicines is still in its early stages despite the fact that they have been associated with many disciplines, including material science, brain science, ultrasound, biology, and medicine. Some aspects of UABD theory and technology remain unclear, especially the mechanisms of BBB opening, relationship between materials of nanomedicines and UABD technology, cavitation and UABD nanomedicines design theories. This review introduces the research status of UABD nanomedicines, investigates their properties and applications of brain tumor therapy, discusses the advantages and drawbacks of UABD nanomedicines for the treatment of brain tumors, and offers their prospects. We hope to encourage researchers from various fields to participate in this area and collaborate on developing UABD nanomedicines into powerful tools for brain tumor therapy.
Collapse
Affiliation(s)
- Shuo Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China
| | - Shuai Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China
| | - Siyuan Luo
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China
| | - Peng Tang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China
| | - Daocheng Wu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China.
| | - Wei Gao
- Department of Anesthesiology and Center for Brain Science and Center for Translational Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, People's Republic of China.
| |
Collapse
|
30
|
Recent Studies on Hydrogels Based on H 2O 2-Responsive Moieties: Mechanism, Preparation and Application. Gels 2022; 8:gels8060361. [PMID: 35735705 PMCID: PMC9222492 DOI: 10.3390/gels8060361] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 05/29/2022] [Accepted: 05/30/2022] [Indexed: 01/04/2023] Open
Abstract
H2O2 is essential for cellular processes and plays a vital role in the regulation of cell signaling pathways, which can be viewed as a warning signal for many kinds of disease including cancer, cardiovascular disease, reproductive abnormalities, diabetes, and renal failure. A H2O2-responsive hydrogel (H2O2-Gel) is a promising candidate for biomedical applications because of its good biocompatibility, similarity to soft biological tissues, ease of preparation, and its ability to respond to H2O2. In this study, the H2O2-responsive moieties used to fabricate H2O2-Gels were reviewed, including thioethers, disulfide bonds, selenides, diselenium bonds, diketones, boronic, and others. Next, the preparation method of H2O2-Gel was divided into two major categories according to their reaction mechanisms: either self-crosslinking or mechanisms entailing the addition of difunctional crosslinkers. Last, the applications of H2O2-Gels were emphasized, which have been viewed as desirable candidates in the fields of drug delivery, the detection of H2O2, glucose-responsive systems, ROS scavengers, tissue engineering, and cell-encapsulation.
Collapse
|
31
|
Dang J, Zhu M, Dong F, Zhong R, Liu Z, Fang J, Zhang J, Pan J. Ultrasound-Activated Nanodroplet Disruption of the Enterococcus faecalis Biofilm in Dental Root Canal. ACS APPLIED BIO MATERIALS 2022; 5:2135-2142. [PMID: 35476392 DOI: 10.1021/acsabm.1c01031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Conventional methods used to control bacterial biofilm infection in root canals have poor efficacy, causing repeated and chronic infections, which pose a great challenge to clinical treatment. Microbubbles, due to their small size and ultrasound (US)-enhanced cavitation effects, have attracted considerable clinical attention. They possess the potential for therapeutic application in restricted spaces. We address the above problem with a strategy for the restricted space of root canals. Herein, phase-change nanodroplets (P-NDs) exposed to US are combined with common antibacterial drugs to disrupt a 7 day Enterococcus faecalis biofilm in an in vitro human tooth model. Specifically, the preparation of P-NDs is based on secondary cavitation. Their average particle size is ∼144 nm, and the stability is favorable. The clearance effect for the biofilm is notable (the disruption rate of P-NDs + US is 63.1%, P < 0.01), while the effect of an antibacterial in conjunction with 2% chlorhexidine (Chx) is significant (the antibiofilm rate of P-NDs@2% Chx + US is 96.2%, P < 0.001). Furthermore, biocompatibility testing on human periodontal ligament fibroblasts demonstrated that P-NDs are safe. In summary, the strategy that we have proposed is suitable for the removal of biofilms in root canals. Notably, it also has great potential for application in the treatment of bacterial infections in restricted spaces.
Collapse
Affiliation(s)
- Jie Dang
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China
| | - Mengqian Zhu
- Department of General Dentistry, Peking University School and Hospital of Stomatology, Beijing 100191, China
| | - Feihong Dong
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China
| | - Ruoqing Zhong
- Department of General Dentistry, Peking University School and Hospital of Stomatology, Beijing 100191, China
| | - Zhengxin Liu
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China
| | - Jing Fang
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China.,College of Engineering, Peking University, Beijing 100871, China
| | - Jue Zhang
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China.,College of Engineering, Peking University, Beijing 100871, China
| | - Jie Pan
- Department of General Dentistry, Peking University School and Hospital of Stomatology, Beijing 100191, China
| |
Collapse
|
32
|
Riis TS, Webb TD, Kubanek J. Acoustic properties across the human skull. ULTRASONICS 2022; 119:106591. [PMID: 34717144 PMCID: PMC8642838 DOI: 10.1016/j.ultras.2021.106591] [Citation(s) in RCA: 39] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 08/05/2021] [Accepted: 09/16/2021] [Indexed: 05/11/2023]
Abstract
Transcranial ultrasound is emerging as a noninvasive tool for targeted treatments of brain disorders. Transcranial ultrasound has been used for remotely mediated surgeries, transient opening of the blood-brain barrier, local drug delivery, and neuromodulation. However, all applications have been limited by the severe attenuation and phase distortion of ultrasound by the skull. Here, we characterized the dependence of the aberrations on specific anatomical segments of the skull. In particular, we measured ultrasound propagation properties throughout the perimeter of intact human skulls at 500 kHz. We found that the parietal bone provides substantially higher transmission (average pressure transmission 31 ± 7%) and smaller phase distortion (242 ± 44 degrees) than frontal (13 ± 2%, 425 ± 47 degrees) and occipital bone regions (16 ± 4%, 416 ± 35 degrees). In addition, we found that across skull regions, transmission strongly anti-correlated (R=-0.79) and phase distortion correlated (R=0.85) with skull thickness. This information guides the design, positioning, and skull correction functionality of next-generation devices for effective, safe, and reproducible transcranial focused ultrasound therapies.
Collapse
Affiliation(s)
- Thomas S Riis
- Department of Biomedical Engineering, University of Utah, Salt Lake City, 84112, UT, United States.
| | - Taylor D Webb
- Department of Biomedical Engineering, University of Utah, Salt Lake City, 84112, UT, United States.
| | - Jan Kubanek
- Department of Biomedical Engineering, University of Utah, Salt Lake City, 84112, UT, United States.
| |
Collapse
|
33
|
Gouveia FV, Ibrahim GM. Habenula as a Neural Substrate for Aggressive Behavior. Front Psychiatry 2022; 13:817302. [PMID: 35250669 PMCID: PMC8891498 DOI: 10.3389/fpsyt.2022.817302] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 01/25/2022] [Indexed: 11/17/2022] Open
Abstract
Over the past decades, an ever growing body of literature has explored the anatomy, connections, and functions of the habenula (Hb). It has been postulated that the Hb plays a central role in the control of the monoaminergic system, thus influencing a wide range of behavioral responses, and participating in the pathophysiology of a number of psychiatric disorders and neuropsychiatric symptoms, such as aggressive behaviors. Aggressive behaviors are frequently accompanied by restlessness and agitation, and are commonly observed in patients with psychiatric disorders, intellectual disabilities, and neurodegenerative diseases of aging. Recently, the Hb has been explored as a new target for neuromodulation therapies, such as deep brain stimulation, with promising results. Here we review the anatomical organization of the habenula and discuss several distinct mechanisms by which the Hb is involved in the modulation of aggressive behaviors, and propose new investigations for the development of novel treatments targeting the habenula to reduce aggressive behaviors.
Collapse
Affiliation(s)
- Flavia Venetucci Gouveia
- Neuroscience and Mental Health, Hospital for Sick Children Research Institute, Toronto, ON, Canada
| | - George M Ibrahim
- Neuroscience and Mental Health, Hospital for Sick Children Research Institute, Toronto, ON, Canada.,Division of Neurosurgery, The Hospital for Sick Children, Toronto, ON, Canada.,Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada.,Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada.,Institute of Medical Science, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
34
|
Durham PG, Dayton PA. Applications of sub-micron low-boiling point phase change contrast agents for ultrasound imaging and therapy. Curr Opin Colloid Interface Sci 2021. [DOI: 10.1016/j.cocis.2021.101498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
35
|
Hou X, Qiu Z, Xian Q, Kala S, Jing J, Wong KF, Zhu J, Guo J, Zhu T, Yang M, Sun L. Precise Ultrasound Neuromodulation in a Deep Brain Region Using Nano Gas Vesicles as Actuators. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:e2101934. [PMID: 34546652 PMCID: PMC8564444 DOI: 10.1002/advs.202101934] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 08/12/2021] [Indexed: 05/02/2023]
Abstract
Ultrasound is a promising new modality for non-invasive neuromodulation. Applied transcranially, it can be focused down to the millimeter or centimeter range. The ability to improve the treatment's spatial resolution to a targeted brain region could help to improve its effectiveness, depending upon the application. The present paper details a neurostimulation scheme using gas-filled nanostructures, gas vesicles (GVs), as actuators for improving the efficacy and precision of ultrasound stimuli. Sonicated primary neurons display dose-dependent, repeatable Ca2+ responses, closely synced to stimuli, and increased nuclear expression of the activation marker c-Fos in the presence of GVs. GV-mediated ultrasound triggered rapid and reversible Ca2+ responses in vivo and could selectively evoke neuronal activation in a deep-seated brain region. Further investigation indicate that mechanosensitive ion channels are important mediators of this effect. GVs themselves and the treatment scheme are also found not to induce significant cytotoxicity, apoptosis, or membrane poration in treated cells. Altogether, this study demonstrates a simple and effective method to achieve enhanced and better-targeted neurostimulation with non-invasive low-intensity ultrasound.
Collapse
Affiliation(s)
- Xuandi Hou
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHung HomHong Kong SAR999077P. R. China
| | - Zhihai Qiu
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHung HomHong Kong SAR999077P. R. China
| | - Quanxiang Xian
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHung HomHong Kong SAR999077P. R. China
| | - Shashwati Kala
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHung HomHong Kong SAR999077P. R. China
| | - Jianing Jing
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHung HomHong Kong SAR999077P. R. China
| | - Kin Fung Wong
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHung HomHong Kong SAR999077P. R. China
| | - Jiejun Zhu
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHung HomHong Kong SAR999077P. R. China
| | - Jinghui Guo
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHung HomHong Kong SAR999077P. R. China
| | - Ting Zhu
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHung HomHong Kong SAR999077P. R. China
| | - Minyi Yang
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHung HomHong Kong SAR999077P. R. China
| | - Lei Sun
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHung HomHong Kong SAR999077P. R. China
| |
Collapse
|
36
|
Lea-Banks H, Hynynen K. Sub-millimetre precision of drug delivery in the brain from ultrasound-triggered nanodroplets. J Control Release 2021; 338:731-741. [PMID: 34530050 DOI: 10.1016/j.jconrel.2021.09.014] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 08/17/2021] [Accepted: 09/12/2021] [Indexed: 12/18/2022]
Abstract
Drug-loaded nanoscale cavitation agents, called nanodroplets, are an attractive solution to enhance and localize drug delivery, offering increased stability and prolonged half-life in circulation compared to microbubbles. However, the spatial precision with which drug can be released and delivered into brain tissue from such agents has not been directly mapped. Decafluorobutane lipid-shell droplets (206 +/- 6 nm) were loaded with a fluorescent blood-brain barrier (BBB)-penetrating dye (Nile Blue) and vaporized with ultrasound (1.66 MHz, 10 ms pulse length, 1 Hz pulse repetition frequency), generating transient echogenic microbubbles and delivering the encapsulated dye. The distribution and intensity of released fluorophore was mapped in a tissue-mimicking phantom, and in the brain of rats (Sprague Dawley, N = 4, n = 16). The release and distribution of dye was found to be pressure-dependent (0.2-3.5 MPa) and to occur only above the vaporization threshold of the nanodroplets (1.5 +/- 0.25 MPa in vitro, 2.4 +/- 0.05 MPa in vivo). Dye delivery was achieved with sub-millimetre spatial precision, covering an area of 0.4 to 1.5 mm in diameter, determined by the sonication pressure. The distribution and intensity of dye released at depth in the brain followed the axial pressure profile of the ultrasound beam. Nile Blue (354 Da, LogP 2.7) was compared to Nile Red (318 Da, LogP 3.8) and Quantum Dots (CdSe/ZnS, 5 nm diameter) to visualize the role of molecule size and lipophilicity in crossing the intact BBB following triggered release. Acoustic emissions were shown to predict the successful delivery of the BBB-penetrating dye and the extent of the distribution, demonstrating the theranostic capabilities of nanoscale droplets to precisely localize drug delivery in the brain.
Collapse
Affiliation(s)
- Harriet Lea-Banks
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada.
| | - Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Canada
| |
Collapse
|
37
|
Ho YJ, Huang CC, Fan CH, Liu HL, Yeh CK. Ultrasonic technologies in imaging and drug delivery. Cell Mol Life Sci 2021; 78:6119-6141. [PMID: 34297166 PMCID: PMC11072106 DOI: 10.1007/s00018-021-03904-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Revised: 07/13/2021] [Accepted: 07/19/2021] [Indexed: 12/14/2022]
Abstract
Ultrasonic technologies show great promise for diagnostic imaging and drug delivery in theranostic applications. The development of functional and molecular ultrasound imaging is based on the technical breakthrough of high frame-rate ultrasound. The evolution of shear wave elastography, high-frequency ultrasound imaging, ultrasound contrast imaging, and super-resolution blood flow imaging are described in this review. Recently, the therapeutic potential of the interaction of ultrasound with microbubble cavitation or droplet vaporization has become recognized. Microbubbles and phase-change droplets not only provide effective contrast media, but also show great therapeutic potential. Interaction with ultrasound induces unique and distinguishable biophysical features in microbubbles and droplets that promote drug loading and delivery. In particular, this approach demonstrates potential for central nervous system applications. Here, we systemically review the technological developments of theranostic ultrasound including novel ultrasound imaging techniques, the synergetic use of ultrasound with microbubbles and droplets, and microbubble/droplet drug-loading strategies for anticancer applications and disease modulation. These advancements have transformed ultrasound from a purely diagnostic utility into a promising theranostic tool.
Collapse
Affiliation(s)
- Yi-Ju Ho
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan
| | - Chih-Chung Huang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
- Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan
| | - Ching-Hsiang Fan
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
- Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan
| | - Hao-Li Liu
- Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan.
| | - Chih-Kuang Yeh
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan.
| |
Collapse
|
38
|
Qin D, Zou Q, Lei S, Wang W, Li Z. Predicting initial nucleation events occurred in a metastable nanodroplet during acoustic droplet vaporization. ULTRASONICS SONOCHEMISTRY 2021; 75:105608. [PMID: 34119737 PMCID: PMC8207230 DOI: 10.1016/j.ultsonch.2021.105608] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Revised: 05/16/2021] [Accepted: 05/21/2021] [Indexed: 06/12/2023]
Abstract
Acoustic droplet vaporization (ADV) capable of converting liquid perfluorocarbon (PFC) micro/nanodroplets into gaseous microbubbles has gained much attention due to its medical potentials. However, its physical mechanisms for nanodroplets have not been well understood due to the disappeared superharmonic focusing effect and the prominent Laplace pressure compared to microdroplets, especially for the initial ADV nucleation occurring in a metastable PFC nanodroplet. The classical nucleation theory (CNT) was modified to describe the ADV nucleation via combining the phase-change thermodynamics of perfluoropentane (PFP) and the Laplace pressure effect on PFP nanodroplets. The thermodynamics was exactly predicted by the Redlich-Kwong equation of state (EoS) rather than the van der Waals EoS, based on which the surface tension of the vapor nucleus as a crucial parameter in the CNT was successfully obtained to modify the CNT. Compared to the CNT, the modified CNT eliminated the intrinsic limitations of the CNT, and it predicted a larger nucleation rate and a lower ADV nucleation threshold, which agree much better with experimental results. Furthermore, it indicated that the nanodroplet properties exert very strong influences on the nucleation threshold instead of the acoustic parameters, providing a potential strategy with an appropriate droplet design to reduce the ADV nucleation threshold. This study may contribute to further understanding the ADV mechanism for PFC nanodroplets and promoting its potential theranostic applications in clinical practice.
Collapse
Affiliation(s)
- Dui Qin
- Chongqing Engineering Research Center of Medical Electronics and Information Technology, Department of Biomedical Engineering, School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, PR China.
| | - Qingqin Zou
- Chongqing Engineering Research Center of Medical Electronics and Information Technology, Department of Biomedical Engineering, School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, PR China
| | - Shuang Lei
- Chongqing Engineering Research Center of Medical Electronics and Information Technology, Department of Biomedical Engineering, School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, PR China
| | - Wei Wang
- Chongqing Engineering Research Center of Medical Electronics and Information Technology, Department of Biomedical Engineering, School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, PR China
| | - Zhangyong Li
- Chongqing Engineering Research Center of Medical Electronics and Information Technology, Department of Biomedical Engineering, School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, PR China.
| |
Collapse
|