1
|
Russo A, Filini O, Mertens E, Daya SM, Conti L, Carones F, Festa G, Boldini A, Savini G. Immediate Sequential Bilateral Implantable Collamer Lens Surgery Is Safe and Effective. J Refract Surg 2024; 40:e313-e320. [PMID: 38717079 DOI: 10.3928/1081597x-20240326-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/19/2024]
Abstract
PURPOSE To assess the clinical outcomes and safety profiles of patients who underwent immediate sequential bilateral phakic lens surgery. METHODS This retrospective multicenter study included 254 consecutive patients (508 eyes) who underwent bilateral same-day Implantable Collamer Lens (ICL) (STAAR Surgical) surgery. The authors focused on 1-year postoperative clinical outcomes and adverse events. RESULTS In the initial cohort, 176 patients (352 eyes) met inclusion criteria. Of these, 335 eyes underwent myopic ICL placement, and 17 eyes received a hyperopic ICL. Notably, 87% of eyes achieved ±0.50 diopters (D) and 95% achieved ±1.00 D of the intended refraction. One year postoperatively, 78% of eyes demonstrated optimal vaulting (250 to 750 µm), with a significant 19% reduction in vaulting observed over the 12 months (P < .001). Only minor adverse events, including early cataract formation (1 case), secondary toric ICL rotation (3 cases), and ICL exchange due to inappropriate vaulting (6 cases), were noted. CONCLUSIONS The findings corroborate the safety and efficacy of immediate sequential bilateral phakic lens surgery and indicate its potential as a treatment option. The low incidence of minor adverse events further reinforces its favorable safety profile. [J Refract Surg. 2024;40(5):e313-e320.].
Collapse
|
2
|
Kırgız A, Yalçınkaya Çakır G, Çakır İ, Yıldırım Y, Ağca A. Seven-Year clinical outcomes after implantation of Eyecryl posterior chamber phakic intraocular lenses for high myopia. Eur J Ophthalmol 2024:11206721241229311. [PMID: 38297492 DOI: 10.1177/11206721241229311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
PURPOSE To evaluate the long-term clinical outcomes, safety and efficacy of Eyecryl posterior-chamber phakic intraocular lens implantation (pIOL) implantation in patients with high myopia. METHODS Patients with myopia between -6.00 and -20.00 dioptres and with endothelial cell density (ECD) was ≥2300 cells/mm2 were included. Preoperative and postoperative first, fourth, and seventh years of refraction, uncorrected/corrected distance visual acuity (UDVA/CDVA), ECD, central vault were detected. RESULTS Thirty-six eyes were analyzed. The mean UDVA and CDVA in postoperative seventh years were 0.25 ± 0.31 and 0.13 ± 0.24 logMAR, respectively. The safety and efficacy indices were 1.55 ± 0.54 and 1.24 ± 0.53, respectively. The mean cumulative ECD loss was 6.96% (p < 0.001). The central vault at the 1st and the 7th year were 0.52 ± 0.14 and 0.49 ± 0.14 mm, respectively (p = 0.25). CONCLUSIONS These findings supported the long-term stability, efficacy, safety of the Eyecryl pIOL for high myopia. Eyecryl posterior chamber pIOL is one of the effective refractive options in correcting high myopia.
Collapse
Affiliation(s)
- Ahmet Kırgız
- University of Health Sciences, Beyoglu Eye Training and Research Hospital, Istanbul, Turkey
| | - Gülay Yalçınkaya Çakır
- University of Health Sciences, Beyoglu Eye Training and Research Hospital, Istanbul, Turkey
| | - İhsan Çakır
- University of Health Sciences, Beyoglu Eye Training and Research Hospital, Istanbul, Turkey
| | - Yusuf Yıldırım
- University of Health Sciences, Beyoglu Eye Training and Research Hospital, Istanbul, Turkey
| | - Alper Ağca
- Atakoy World Eye Hospital, Istanbul, Turkey
| |
Collapse
|
3
|
Naujokaitis T, Auffarth GU, Łabuz G, Khoramnia R. Endothelial Cell Loss in Patients with Phakic Intraocular Lenses. Klin Monbl Augenheilkd 2024. [PMID: 38242162 DOI: 10.1055/a-2209-5251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2024]
Abstract
Although the safety of phakic intraocular lenses (pIOLs) has been continuously improved over 70-years of development, high endothelial cell losses can occur even with current pIOL models. Numerous studies have demonstrated that the distance of a pIOL to the corneal endothelium plays a crucial role in the extent of endothelial cell loss. For this reason alone, higher endothelial cell loss tends to be observed with anterior chamber lenses than with posterior chamber lenses. Adequate preoperative anterior chamber depth is essential, at least for iris-fixed pIOLs, in order to ensure a safe distance from the endothelium. However, the anterior chamber becomes shallower with age and therefore it may be useful to consider patient age in the safety criteria. Although endothelial cell loss is generally low with current pIOL models, regular monitoring of the endothelial cell density remains essential due to large interindividual differences in patients with pIOLs. If the endothelial cell loss is greater than expected and the follow-up visits confirm the trend, the pIOL should be explanted without delay. The endothelial reserve should be considered on an individual basis by taking into account patient age, physiological endothelial cell loss, and loss due to further surgery. With careful indication and long-term patient care, pIOLs remain a safe treatment option.
Collapse
Affiliation(s)
- Tadas Naujokaitis
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| | - Gerd U Auffarth
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| | - Grzegorz Łabuz
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| | - Ramin Khoramnia
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| |
Collapse
|
4
|
Du J, Zhou W, Zhao T, Qian T, Lu Y, Li H, Zhang Z, Lian J. Efficacy and Safety of Implantable Collamer Lens V4c Implantation in 1,834 Myopic Eyes for 1 Year of Follow-up. J Refract Surg 2023; 39:694-704. [PMID: 37824302 DOI: 10.3928/1081597x-20230908-02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2023]
Abstract
PURPOSE To evaluate visual outcomes of patients with myopia after EVO Implantable Collamer Lens (ICL) (STAAR Surgical) implantation and predict risk factors of postoperative vault abnormalities. METHODS In this single-center, retrospective analysis, 1,834 eyes of 926 patients with myopia who underwent EVO ICL implantation were recruited between 2020 and 2021. Patients were followed up for 1 year, during which surgery outcomes were evaluated. In addition, 31 eyes with vault abnormalities who underwent secondary surgery were enrolled to form a generalized linear model, which aimed to predict risk factors contributing to vault abnormalities. RESULTS At the final follow-up visit, safety and efficacy indexes were 1.12 ± 0.17 and 1.10 ± 0.19, respectively, and there was no statistical significance between the low and high myopia groups. Furthermore, 79.18% of eyes achieved a residual spherical equivalent within ±0.50 diopters. Except for the temporary elevation of intraocular pressure at 1 week postoperatively, IOP and endothelial cell density remained stable during follow-up visits. The rate of postoperative adverse events was 21.97% and most adverse events were transient. Vault abnormalities accounted for the majority of complications (9.54%). Results of generalized linear model showed that age was a risk factor for postoperative vault abnormalities, and the anterior chamber depth served as a protective factor (P < .05). CONCLUSIONS Visual outcomes of EVO ICL implantation were satisfactory in safety and efficacy indexes in both the low and high myopia groups for 1 year of follow-up, with acceptable stability in postoperative spherical equivalent, intraocular pressure, and endothelial cell density. This study emphasized cautious ICL size selection for older patients and those with shallow anterior chamber depth. [J Refract Surg. 2023;39(10):694-704.].
Collapse
|
5
|
Luo W, Aruma A, Li M, Wang J, Xie J, Xiao X, Shen Y, Niu L, Wang X, Zhou X. Four-year visual outcomes and optical quality of SMILE and implantable collamer lens V4c (EVO-ICL) implantation for high myopia: a retrospective study. BMC Ophthalmol 2023; 23:341. [PMID: 37525155 PMCID: PMC10392000 DOI: 10.1186/s12886-023-03050-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Accepted: 06/18/2023] [Indexed: 08/02/2023] Open
Abstract
BACKGROUND To compare the 4-year visual outcomes of implantable collamer lens V4c (EVO-ICL) implantation and small incision lenticule extraction (SMILE) for high myopia and astigmatism. METHODS This retrospective case study included 64 eyes of 40 patients. These patients with preoperative manifest refraction spherical equivalent (SE) between - 6.00 and - 10.00 diopters (D) were screened from the database of SMILE and EVO-ICL implantation procedures in 2015. The ICL group [32 eyes of 19 patients (mean age, 29.6 ± 6.3 years); mean SE, -8.71 ± 1.06 D] and SMILE group [32 eyes of 21 patients (mean age, 27.7 ± 5.6 years); mean SE, -8.35 ± 0.65D] were compared. All patients were then prospectively examined at a four-year follow-up for routine postoperative examinations, higher-order ocular aberrations, retinal image quality and a questionnaire. RESULTS The safety indexes were 1.15 ± 0.14 and 1.22 ± 0.21 (P = 0.36) for the SMILE and ICL groups, respectively. No eyes lost two or more lines of CDVA in either group. The efficacy indexes were 0.97 ± 0.16 and 0.96 ± 0.19 (P = 0.87), respectively. Twenty-three eyes (72%) in ICL and 26 eyes (81%) in SMILE groups were within ± 0.5 D of the attempted SE (P < 0.01). ICL-treated eyes had significantly less spherical aberration and coma (P < 0.01 and < 0.05, respectively) postoperatively. Halos were the prevalent visual disturbance in both groups. CONCLUSION SMILE and EVO-ICL implantation provided safe and effective correction of high myopia. SMILE showed slightly better long-term predictability. Mild postoperative visual disturbances were observed after ICL and SMILE at 4-year follow-up.
Collapse
Affiliation(s)
- Wuqiang Luo
- Visual Science and Optometry Center, the People's Hospital of Guangxi Zhuang Autonomous Region, Nanning, 530021, Guangxi Zhuang Autonomous Region, China
| | - Aruma Aruma
- Department of Ophthalmology, NHC Key Laboratory of Myopia, Shanghai Research Center of Ophthalmology and Optometry, Eye and ENT Hospital of Fudan University, 200433, Shanghai, China
| | - Meiyan Li
- Department of Ophthalmology, NHC Key Laboratory of Myopia, Shanghai Research Center of Ophthalmology and Optometry, Eye and ENT Hospital of Fudan University, 200433, Shanghai, China
| | - Jing Wang
- Aier Eye Hospital Group, Aier Eye Hospital of Wuhan University, 430063, Wuhan, Hubei Province, China
| | - Jing Xie
- Department of Ophthalmology, Shenzhen Key Laboratory of ENT, Institute of ENT Shenzhen, Longgang ENT hospital, 518172, Shenzhen, China
| | - Xin Xiao
- Visual Science and Optometry Center, the People's Hospital of Guangxi Zhuang Autonomous Region, Nanning, 530021, Guangxi Zhuang Autonomous Region, China
| | - Yang Shen
- Department of Ophthalmology, NHC Key Laboratory of Myopia, Shanghai Research Center of Ophthalmology and Optometry, Eye and ENT Hospital of Fudan University, 200433, Shanghai, China
| | - Lingling Niu
- Department of Ophthalmology, NHC Key Laboratory of Myopia, Shanghai Research Center of Ophthalmology and Optometry, Eye and ENT Hospital of Fudan University, 200433, Shanghai, China
| | - Xiaoying Wang
- Department of Ophthalmology, NHC Key Laboratory of Myopia, Shanghai Research Center of Ophthalmology and Optometry, Eye and ENT Hospital of Fudan University, 200433, Shanghai, China
| | - Xingtao Zhou
- Department of Ophthalmology, NHC Key Laboratory of Myopia, Shanghai Research Center of Ophthalmology and Optometry, Eye and ENT Hospital of Fudan University, 200433, Shanghai, China.
- Department of Ophthalmology and Optometry, Myopia Key Laboratory of the Health Ministry, Eye and ENT Hospital of Fudan University, No.83 Fenyang Road, 200031, Shanghai, People's Republic of China.
| |
Collapse
|
6
|
Naujokaitis T, Auffarth GU, Łabuz G, Kessler LJ, Khoramnia R. Diagnostic Techniques to Increase the Safety of Phakic Intraocular Lenses. Diagnostics (Basel) 2023; 13:2503. [PMID: 37568866 PMCID: PMC10417808 DOI: 10.3390/diagnostics13152503] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 07/25/2023] [Accepted: 07/25/2023] [Indexed: 08/13/2023] Open
Abstract
Preoperative and postoperative diagnostics play an important role in ensuring the safety of patients with phakic intraocular lenses (pIOLs). The risk of endothelial cell loss can be addressed by regularly measuring the endothelial cell density using specular microscopy and considering the endothelial cell loss rate and the endothelial reserve in accordance with the patient's age when deciding whether to explant a pIOL. The anterior chamber morphometrics, including the anterior chamber depth and the distance between the pIOL and the endothelium, measured using Scheimpflug tomography and anterior segment optical coherence tomography (AS-OCT), can help to assess the risk of the endothelial cell loss. In patients undergoing posterior chamber pIOL implantation, accurate prediction of the vault and its postoperative measurements using AS-OCT or Scheimpflug tomography are important when assessing the risk of anterior subcapsular cataract and secondary glaucoma. Novel approaches based on ultrasound biomicroscopy and AS-OCT have been proposed to increase the vault prediction accuracy and to identify eyes in which prediction errors are more likely. Careful patient selection and regular postoperative follow-up visits can reduce the complication risk and enable early intervention if a complication occurs.
Collapse
Affiliation(s)
| | | | | | | | - Ramin Khoramnia
- Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany
| |
Collapse
|
7
|
Caixia L, Yawen B, Yuxin F, Xiaoxia L, Yuhan W, Ke Y, Liya Q. Clinical outcomes of implantation of posterior chamber phakic intraocular lens for pathologic and non-pathologic myopia. BMC Ophthalmol 2023; 23:172. [PMID: 37085809 PMCID: PMC10120149 DOI: 10.1186/s12886-023-02890-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Accepted: 03/30/2023] [Indexed: 04/23/2023] Open
Abstract
BACKGROUND To compare the clinical outcomes of posterior chamber phakic intraocular lens (pIOL) implantation for non-pathological myopia and pathological myopia. METHODS This retrospective case series study which were conducted in Beijing Tongren Eye Center between July 2017 and Oct 2021 comprised 192 eyes of 100 consecutive patients undergoing pIOL implantation. Eyes were divided into two groups based on having pathological myopia or not. Predictability, efficacy, safety, and adverse events were compared at 6 months after pIOL implantation. RESULTS Our study included 86 non-pathological myopes (171 eyes, group1) and 14 pathological myopes (21eyes, group2) to analysis. The average ages were 25.5 and 33.0, respectively, and the spherical equivalent (SE) were -9.31D and -17.50D pre-operation. Six months after pIOL implantation, the SE were 0.00 and -0.50, respectively, and the refraction changes were statistically significant (P ≤ 0.05). Six months after surgery, 76.92% and 80.41% were within ± 0.50 D of the target and 92.31% and 95.88% were within ± 1.00 D. All eyes had unchanged BCVA or gained 1 or more lines in both groups and mean BCVA both improved a line 6m after operation. The efficacy index in the two groups were 0.95 and 0.88 and the safety index were 1.20, 1.33, respectively which was significantly different (P ≤ 0.05). Over the 6-month follow-up, no cataract, pigment dispersion glaucoma, pupillary block, or other vision-threatening complications happened, either. CONCLUSIONS The pIOL performed well for the correction of both non-pathological and pathological myopia throughout the 6-month observation period. The clinical outcomes of pIOL implantation for non-pathological myopia are essentially equivalent to those for pathological myopia.
Collapse
Affiliation(s)
- Lin Caixia
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No. 1 Dong Jiao Min Xiang Street, Dongcheng District, Beijing, 100730, People's Republic of China
| | - Bai Yawen
- Ophthalmology Department, Beijing Shijitan Hospital, Capital Medical University, No. 10 Tieyi Road, Yangfangdian, Haidian District, Beijing, 100038, People's Republic of China
| | - Fang Yuxin
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No. 1 Dong Jiao Min Xiang Street, Dongcheng District, Beijing, 100730, People's Republic of China
| | - Li Xiaoxia
- Ophthalmology Department, Beijing Shijitan Hospital, Capital Medical University, No. 10 Tieyi Road, Yangfangdian, Haidian District, Beijing, 100038, People's Republic of China
| | - Wang Yuhan
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No. 1 Dong Jiao Min Xiang Street, Dongcheng District, Beijing, 100730, People's Republic of China
| | - Yang Ke
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No. 1 Dong Jiao Min Xiang Street, Dongcheng District, Beijing, 100730, People's Republic of China
| | - Qiao Liya
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No. 1 Dong Jiao Min Xiang Street, Dongcheng District, Beijing, 100730, People's Republic of China.
| |
Collapse
|
8
|
Cakir I, Sonmez O, Pehlivanoglu S, Cakir GY, Yildiz BK, Yildirim Y, Agca A. Long-term results of a new posterior chamber phakic intraocular lens in patients with high myopia: 5-year results. J Cataract Refract Surg 2023; 49:409-415. [PMID: 36888565 DOI: 10.1097/j.jcrs.0000000000001110] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Accepted: 11/27/2022] [Indexed: 03/09/2023]
Abstract
PURPOSE To evaluate the long-term refractive outcomes of Eyecryl posterior chamber spherical phakic intraocular lens (pIOL) implantation in high myopia and endothelial cell density (ECD) change. SETTING Beyoglu Eye Training and Research Hospital, Istanbul, Turkey. DESIGN Retrospective. METHODS Eyes that were not suitable for corneal refractive surgery, had high myopia between -6.00 diopters (D) and -20.00 D, had Eyecryl posterior chamber spherical pIOL implantation, and had at least 5 years of follow-up were included. Preoperative ECD was ≥2300 cells/mm 2 and cylindrical value was ≤2.0 D in all cases. Preoperative and postoperative first, third, and fifth years of refraction, uncorrected and corrected distance visual acuity (UDVA/CDVA), and ECD were recorded. RESULTS 36 eyes of 18 patients were examined. The mean UDVA and CDVA in postoperative fifth years were 0.24 ± 0.19 logMAR and 0.12 ± 0.18 logMAR, respectively. The safety and efficacy indices were 1.52 ± 0.54 and 1.14 ± 0.38, respectively. At 5 years, the spherical equivalent was ±0.50 D in 75% of eyes and ±1.00 D in 92% of eyes. After 5 years, the mean cumulative ECD loss was 6.91% ( P = .07). The annual ECD loss was 1.57% in the first year, 0.26% between 1 year and 3 years, and 2.38% between 3 years and 5 years. Asymptomatic anterior capsule opacity developed in 1 eye 4 years after surgery. Rhegmatogenous retinal detachment developed in 1, and myopic choroidal neovascular membrane occurred in 1 eye. CONCLUSIONS Eyecryl posterior chamber spherical pIOL implantation is one of the effective and safe refractive surgical methods in correcting high myopia with predictable and stable refractive results over a 5-year period. Longer-term studies are needed for complications such as decreased ECD, retinal complications, and lens opacity.
Collapse
Affiliation(s)
- Ihsan Cakir
- From the Beyoglu Eye Training and Research Hospital, University of Health Sciences, Istanbul, Turkey (I. Cakir, Sonmez, Pehlivanoglu, G.Y. Cakir, Yildiz, Yildirim); Atakoy World Eye Hospital, Istanbul, Turkey (Agca)
| | | | | | | | | | | | | |
Collapse
|
9
|
Zhang H, Gong R, Zhang X, Deng Y. Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation. Int Ophthalmol 2022; 42:3625-3641. [PMID: 35731355 PMCID: PMC9587946 DOI: 10.1007/s10792-022-02355-w] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Accepted: 04/18/2022] [Indexed: 02/05/2023]
Abstract
PURPOSE To introduce a modified procedure of ICL implantation, to summarize the perioperative problems and their corresponding treatment after myopia correction with Implantable Collamer Lens (ICL), and to compare the difference of complications between the no-hole ICL and hole ICL. METHODS We searched all articles on ICL-related perioperative problems and their corresponding treatment in Scopus, Embase, PubMed and Web of Science databases for the last 22 years. RESULTS ICL implantation is safe, effective, stable and predictable in the correction of myopia, hyperopia and astigmatism, but can also cause a series of perioperative problems, including intraoperative and postoperative complications. CONCLUSION There are many kinds of complications related to ICL, but the common intraoperative and postoperative complications mainly include abnormality of arch height, abnormal position of ICL, loss of corneal endothelial cells and corneal decompensation, high intraocular pressure and secondary glaucoma, cataract and night vision symptoms. Compared with ICL without central pore, the incidence of complications such as loss of corneal endothelial cells and corneal decompensation, high intraocular pressure and secondary glaucoma and cataract was relatively lower in central hole ICL, while postoperative complications such as night vision symptoms were obvious.
Collapse
Affiliation(s)
- Hao Zhang
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Rui Gong
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Xiaolan Zhang
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Yingping Deng
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| |
Collapse
|
10
|
Wang Y, Yang R, Huang Y, Zhang C, Liu H, Jia Z, Zhao S. Clinical observations of EVO-ICL implantation and changes in corneal astigmatism using a modified technique. BMC Ophthalmol 2022; 22:381. [PMID: 36151534 PMCID: PMC9502894 DOI: 10.1186/s12886-022-02603-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Accepted: 09/13/2022] [Indexed: 11/23/2022] Open
Abstract
Background Implantable collamer lens (ICL) surgery techniques are constantly progressing. The purpose of this study was to investigate the application effect of the modified technique and its impact on the change in corneal astigmatism in EVO-ICL surgery. Methods The analysis of retrospective cohort data included 153 eyes of 81 patients with myopia from July 2018 to May 2020. An EVO-ICL was inserted by modified surgical skills, including a single 3.0 mm corneal incision and no ophthalmic viscosurgical device (OVD) before the insertion of the ICL (modified technique group: 41 cases, 80 eyes) and standard procedure (standard technique group: 40 cases, 73 eyes). Early postoperative intraocular pressure (IOP) was monitored at 2 and 24 h. IOP, corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), vault, and anterior chamber depth (ACD) were measured 1, 6, and 12 months following the initial examination. The corneal endothelial cell density (ECD) was monitored at 6 and 12 months after the operation. Surgically induced astigmatism (SIA) in the total, anterior, and posterior corneal surfaces was analysed 1 month after the operation. Results No serious complications were detected. The two groups had no difference in visual outcomes, ICL vaults, or ACD at any time point (P > 0.05). Two hours postoperatively, IOP was significantly lower in the modified technique group (16.22 ± 2.22 vs. 18.37 ± 1.92 mmHg, P < 0.05) than in the standard technique group. IOP decreased gradually after 24 h to preoperative levels. The postoperative IOP remained stable over a 12-month period. The ECD at 6 and 12 months was not significantly different between the groups (P > 0.05). SIA in the total, anterior, and posterior corneal surfaces were assumed to have no clinically meaningful differences between groups at one month after operation (P > 0.05). Conclusions The modified technique is efficient and safe, producing comparable visual and structural outcomes without adversely affecting ECD, and reduces fluctuations in IOP at the early postoperative stages. The auxiliary incision in the standard technique does not increase corneal SIA, which is also a factor to consider for inexperienced surgeons.
Collapse
Affiliation(s)
- Ying Wang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, 300384, China
| | - Ruibo Yang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, 300384, China
| | - Yue Huang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, 300384, China
| | - Chen Zhang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, 300384, China
| | - Hui Liu
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, 300384, China
| | - Zhe Jia
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, 300384, China
| | - Shaozhen Zhao
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, 300384, China.
| |
Collapse
|
11
|
Packer KT, Vlasov A, Greenburg DL, Coggin A, Weightman JW, Beltran T, Berry-Cabán CS, Carroll RB. U.S. military implantable collamer lens surgical outcomes: 11-year retrospective review. J Cataract Refract Surg 2022; 48:649-656. [PMID: 34653095 DOI: 10.1097/j.jcrs.0000000000000818] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 09/10/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To examine the long-term efficacy and safety of myopic implantable collamer lens (ICL) implantation in active duty personnel of U.S. military. SETTING Hospital practice. DESIGN Retrospective longitudinal observational study. METHODS 1485 patients (median age 25, interquartile range 22 to 29) underwent ICL surgery. Patients received a preoperative examination including uncorrected distance visual acuity (UDVA), intraocular pressure (IOP), manifest refraction measuring corrected distance visual acuity (CDVA), corneal topography and tomography, qualitative grading of perceived ectatic risk, ophthalmic biometry, and baseline endothelial cell counts (ECCs). Outcome measures included UDVA, IOP, vault size, manifest refraction, CDVA, and ECCs. The long-term follow-up data ware drawn from the U.S. military medical record system. RESULTS A total of 3105 eyes were evaluated. Patients received ICLs because of either abnormal topography (2111 eyes [68%]) or high myopia (994 eyes [32%]). 94 eyes (80%) maintained UDVA of 20/25 or better up to 8 years postoperatively. The rate of achieving the desired refractive correction was 97% (503 eyes) at 1 year and 90% (81 eyes) at 8 years. Stability of these outcomes was also shown by minimal change in manifest refraction. Documented mean ECC loss was 22% at postoperative year 5. The overall rate of adverse events was 1.2% (36 eyes) including visually significant cataract formation, glaucoma, retinal detachment, and traumatic incision opening. A removal or replacement rate of 4.5% (135 eyes) was observed. CONCLUSIONS ICL implantation was found to be effective and safe. Vault sizes decreased over time, suggesting an increased risk of cataract formation after 7 years. Further study is necessary to assess long-term clinical significance of ECC decline.
Collapse
Affiliation(s)
- Kyle T Packer
- From the Department of Ophthalmology, Womack Army Medical Center, Fort Bragg, North Carolina (Packer, Vlasov, Greenburg, Coggin, Weightman, Carroll); Department of Clinical Investigation, Womack Army Medical Center, Fort Bragg, North Carolina (Beltran, Berry-Cabán)
| | | | | | | | | | | | | | | |
Collapse
|
12
|
A Prospective Comparative Study between Implantable Phakic Intraocular Contact Lens and Implantable Collamer Lens in Treatment of Myopia in Adults. J Ophthalmol 2022; 2022:9212253. [PMID: 35388352 PMCID: PMC8979746 DOI: 10.1155/2022/9212253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Revised: 02/07/2022] [Accepted: 03/18/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose To compare implantable collamer lenses (ICLs) and acrylic implantable phakic contact lenses (IPCLs) in the treatment of myopia in adults, as regards refractive outcome and adverse effects. Methods Prospective, randomized comparative study with phakic intraocular lenses (IOLs) was carried out for treatment of myopia. Patients were randomized into two groups: one for ICL and the other for IPCL. Preoperative assessments included a full examination, pentacam, endothelial cell count, and biometry. We compared the adverse effects and refractive outcomes between both groups. The study was registered in clinical trials and the registration number is NCT04624035. Results Sixty eyes of sixty patients (28 in the ICL group and 32 in the IPCL group) with a follow-up period of 12 months. The mean preoperative spherical equivalent was −12.7 ± 3.4 D and −13.6 ± 4.4 D in the ICL and IPCL groups, respectively (P=0.37). The mean postoperative spherical equivalent value was ±0.4 ± 0.2 D and ±0.6 ± 0.1 D in the ICL and IPCL groups, respectively. Uncorrected visual acuity (UCVA) has improved from 1.3 ± 0.06 to 0.15 ± 0.02 Log MAR in the ICL group (P < 0.001) and from 1.3 ± 0.02 to 0.15 ± 0.01 Log MAR in the IPCL group (P < 0.001). The mean endothelial cell count was reduced by 3.3% in the IPCL group and by 3.2% in the IPCL group. Conclusion Both ICL and IPCL are effective methods to correct high myopia in adults with no statistically significant differences between the two lenses as regarding adverse effects.
Collapse
|
13
|
Phakic intraocular lens explantation: a series of 175 surgeries. J Cataract Refract Surg 2022; 48:1004-1009. [PMID: 35239580 DOI: 10.1097/j.jcrs.0000000000000920] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Accepted: 02/16/2022] [Indexed: 11/25/2022]
Abstract
PURPOSE The ideal timing for phakic intraocular lens (pIOL) explantation remains unknown. Our study aims to evaluate the indications for pIOL explantation, pIOL survival time, visual outcomes, and access endothelial cell loss (ECL) after explantation. SETTING Ophthalmology Department, Centro Hospitalar Universitário do Porto, Portugal. Design: Retrospective longitudinal study. METHODS Chart review was performed for all consecutive patients that underwent pIOL explantation from January 2010 to December 2019 in a single center. RESULTS This study included 175 eyes of 112 patients, 77% of which were female. Phakic IOL survival was 12.9 ± 4.8 [3.7 - 28.6] years and the follow-up period after explantation was 4.1 ± 3.0 [0.3 - 9.9] years. The most frequent causes for explantation were cataract formation (44.0%, n=77) and ECL (50.3%, n=88). During the follow-up period after explantation, mean ECL rate was 2.27 ± 9.32 %/year in the cataract group and -2.14 ± 10.24 %/year in the ECL group, reflecting a positive change in cell density in the latter. Eight eyes (4.6%) required a corneal transplant during the follow-up. Mean corrected distance visual acuity was 0.17 ± 0.24 logMAR at the last visit. CONCLUSION Our study demonstrates that pIOL explantation, after an average survival time of 13 years, is a safe procedure. The main causes for explantation were cataract formation and ECL. Most patients show a sustained improvement in visual acuity and endothelial cell density after pIOL explantation, and yet its timing should be ideal to avoid irreversible complications.
Collapse
|
14
|
Li L, Zhang B, Wang Z. Comparison of accommodation and accommodative micro-fluctuation after implantable collamer lens and LASIK surgery for myopia. BMC Ophthalmol 2022; 22:8. [PMID: 34983448 PMCID: PMC8725356 DOI: 10.1186/s12886-021-02217-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Accepted: 12/15/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND To longitudinally analyze and compare the accommodative micro-fluctuation (MFs) and accommodative function between myopic patients after implantable collamer lens (ICL) implantation and laser in situ keratomileusis (LASIK). METHODS Patients with good corrected visual acuity (20/20 or better) and underwent ICL (V4c) and LASIK for myopic-correction (ranging from - 3.50 to - 8.50 D) were recruited. Refraction, amplitude of accommodation (AMP), accommodative lag, higher-order aberration (HOA), and MFs were recorded before surgery and 1 and 3 months after surgery. The ACOMEREF automatic refractor was used to measure the high-frequency component (HFC) of the MFs, which suggested tension of the ciliary muscle. RESULTS The study comprised 120 eyes. At 3 months after surgery, the manifest refractive spherical equivalent of the ICL and LASIK groups were - 0.11 and - 0.09 D, respectively (p = 0.46). HFC values were significantly higher at 1 month (p = 0.03) and 3 months postoperatively (p = 0.03) in the ICL group compared to that in the LASIK group. The ocular HOA of the ICL group was 1.08 ± 0.43 μm, which was lower than the LASIK group 1.45 ± 0.54 μm (p = 0.01). No significant differences in AMP and accommodative lag between groups were noted at 3 months postoperatively. There was a positive correlation between HFC and vault of the ICL lens (r2 = 0.14, p = 0.005). There were no correlations between HFC and ocular HOA and postoperative MRSE in the two groups (all p>0.05). CONCLUSIONS The HFC increased significantly after an early period of ICL implantation compared to laser in situ keratomileusis for myopic correction, which indicated increased tension of the ciliary muscle, and had a positive correlation on the vault of the ICL lens; However, studies with longer follow-up time and more structural evaluation are needed.
Collapse
Affiliation(s)
- Li Li
- Aier School of Ophthalmology, Central South University, Fourth Floor, New Century Mansion, 198 Middle Furong Road, Changsha, China.,Department of Refractive Surgery, Guangzhou Aier Eye Hospital, Guangzhou, China.,Chongqing Eye and Vision Care Hospital, Chongqing, China.,Aier Institute of Refractive Surgery, Aier Eye Hospital Group, Changsha, China
| | - Bo Zhang
- Department of Refractive Surgery, Guangzhou Aier Eye Hospital, Guangzhou, China.,Aier Institute of Refractive Surgery, Aier Eye Hospital Group, Changsha, China
| | - Zheng Wang
- Aier School of Ophthalmology, Central South University, Fourth Floor, New Century Mansion, 198 Middle Furong Road, Changsha, China. .,Department of Refractive Surgery, Guangzhou Aier Eye Hospital, Guangzhou, China. .,Aier Institute of Refractive Surgery, Aier Eye Hospital Group, Changsha, China.
| |
Collapse
|
15
|
Guan N, Zhang XN, Zhang WJ. Correlation between intraoperative and postoperative vaulting of the EVO implantable Collamer lens: a retrospective study of real-time observations of vaulting using the RESCAN 700 system. BMC Ophthalmol 2022; 22:2. [PMID: 34980022 PMCID: PMC8721482 DOI: 10.1186/s12886-021-02237-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Accepted: 12/22/2021] [Indexed: 12/19/2022] Open
Abstract
Background Implantable Collamer lens (ICL) vaulting is one of the most important parameters for the safety, aqueous humor circulation, and lens transparency after ICL implantation. This study aimed to investigate the factors associated with the actual vaulting after refractive EVO-ICL surgery. Methods This retrospective study included patients who underwent EVO-ICL surgery at a tertiary eye hospital between October and December 2019. A RESCAN 700 was used for the intraoperative and CIRRUS HD-OCT was used for postoperative observation of vaulting. Subjective and objective refractions, anterior ocular segment, corneal morphology, intraocular pressure (IOP), anterior chamber volume (ACV), crystalline lens rise (CLR), white-to-white distance (WTW), anterior chamber depth (ACD), axial length, corneal endothelial cell density (ECD), and fundoscopy were examined. A multivariable analysis was performed to determine the factors independently associated with 1-month postoperative vaulting. Results Fifty-one patients (102 eyes) were included. Compared with the eyes with normal vaulting, those with high vaulting had higher preoperative diopter values (P = 0.039), lower preoperative corrected visual acuity (P = 0.006), lower preoperative IOP (P = 0.029), higher preoperative ACD (P = 0.004), lower preoperative CLR (P = 0.046), higher ICL spherical equivalent (P = 0.030), higher intraoperative vaulting (P < 0.001), and lower IOP at 1 month (P = 0.045). The multivariable analysis showed that the only factor independently associated with high vaulting at 1 month after surgery was the intraoperative vaulting value (odds ratio = 1.005, 95% confidence interval: 1.002–1.007, P < 0.001). The intraoperative and 1-month postoperative vaulting values were positively correlated (R2 = 0.562). Conclusions The RESCAN700 system can be used to perform intraoperative optical coherence tomography to predict the vaulting value of ICL at 1 month.
Collapse
Affiliation(s)
- Nian Guan
- Department of Refractive, Wuhan Bright Eye Hospital, Wuhan, 430000, Hubei, China
| | - Xiao-Nong Zhang
- Department of Refractive, Hefei Bright Eye Hospital, Hefei, 230000, Anhui, China
| | - Wan-Jun Zhang
- Department of Refractive, Hefei Bright Eye Hospital, Hefei, 230000, Anhui, China.
| |
Collapse
|
16
|
Alhamzah A, Alharbi SS, Alfardan F, Aldebasi T, Almudhaiyan T. Indications for exchange or explantation of phakic implantable collamer lens with central port in patients with and without keratoconus. Int J Ophthalmol 2021; 14:1714-1720. [PMID: 34804861 DOI: 10.18240/ijo.2021.11.10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Accepted: 06/16/2021] [Indexed: 11/23/2022] Open
Abstract
AIM To evaluate the causes of phakic implantable collamer lens (ICL) exchange/explantation in patients with and without keratoconus (KC) at two tertiary hospitals in Riyadh, Saudi Arabia. METHODS A retrospective chart review of all patients who underwent ICL (model V4c with central port) exchange/explantation was performed using the electronic medical record systems. All available preoperative and postoperative data were documented for each patient. RESULTS Over 7y, 2283 ICL implantation procedures were performed; 46 implants (2%) required exchange (21 implants)/explantation (25 implants), of which 14 cases (30.4%) were patients with KC. Indications for ICL exchange/explantation in non-KC group were vault measurement, cataract formation, increased intraocular pressure, inaccurate refraction, and patient dissatisfaction in 22 (68.75%), 4 (12.5%), 3 (9.37%), 2 (6.25%), and 1 (3.12%) case, respectively. The most common indication for ICL exchange/explantation in the KC group was inaccurate vault sizing in 11 patients (78.57%), inaccurate refraction in 2 patients (14.28%), and patient dissatisfaction postoperatively in 1 (7.14%) case. CONCLUSION ICL implantation results in predictable refractive outcomes over the long term with exchange/explantation rates comparable to previous literature. Improper vault size is the most common cause of ICL exchange/explantation among patients with or without KC.
Collapse
Affiliation(s)
- Albanderi Alhamzah
- King Saud bin Abdulaziz University for Health Sciences, College of Medicine, Riyadh 22490, Saudi Arabia
| | - Saad S Alharbi
- Anerior Segment Department, King Khaled Eye Specialist Hospital, Riyadh 7191, Saudi Arabia
| | - Fahad Alfardan
- Department of Surgery, Division of Ophthalmology, National Guard Hospital, Riyadh 22490, Saudi Arabia.,King Abdullah International Medical Research Center, Riyadh 22490, Saudi Arabia
| | - Tariq Aldebasi
- Department of Surgery, Division of Ophthalmology, National Guard Hospital, Riyadh 22490, Saudi Arabia
| | - Tariq Almudhaiyan
- Department of Surgery, Division of Ophthalmology, National Guard Hospital, Riyadh 22490, Saudi Arabia.,King Abdullah International Medical Research Center, Riyadh 22490, Saudi Arabia
| |
Collapse
|
17
|
Evaluation of Visual Outcome of 2 Phakic Posterior Chamber Implantable Lenses in High Myopia: A Comparative Study. Eye Contact Lens 2021; 48:38-44. [PMID: 34775453 DOI: 10.1097/icl.0000000000000854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/09/2021] [Indexed: 10/19/2022]
Abstract
PURPOSE To evaluate and compare the visual outcomes of two phakic intraocular lenses in high myopia. METHODS A prospective comparative study was undertaken on 50 eyes of 26 patients {age ≥21 years and divided into two groups (implantable collamer lens [ICL] V4c, n=25 eyes and refractive implantable lens [RIL], n=25 eyes)}. Patients were evaluated for uncorrected distance visual acuity (UCVA), best-corrected distance visual acuity, manifest refractive spherical equivalent (MRSE), contrast sensitivity, intraocular pressure, dilated fundus examination, trabecular-iris angle (TIA), anterior chamber depth, horizontal white-to-white diameter, wavefront aberrometry, and endothelial cell (EC) count. All patients were followed up until 6 months and additionally evaluated for anterior chamber inflammation, cataract, and lens vault. RESULTS The baseline parameters (UCVA, MRSE, and EC count) and postoperative improvement in UCVA, contrast sensitivity, MRSE, EC loss, safety index, and efficacy index were comparable between both the lenses. The improvement in aberrometric profile was significantly better in the ICL group. The mean postoperative vault was higher in RIL group (434.88±162.48 μm vs. 547.24±159.83 μm, P=0.0173); however, the vault was within normal range in both the groups. The decrease in mean TIA was significantly higher in RIL group (8.58 vs. 13.45 μm, P=0.0073). CONCLUSION Acrylic phakic lens can be considered as a suitable alternative to collamer lens for refractive correction of high myopia. The collamer lenses showed slight superiority in some qualitative visual parameters; however, collamer lenses do not present with subjective complaints in the patients.
Collapse
|
18
|
Initial clinical outcomes of two different phakic posterior chamber IOLs for the correction of myopia and myopic astigmatism. Graefes Arch Clin Exp Ophthalmol 2021; 260:1763-1772. [PMID: 34741659 DOI: 10.1007/s00417-021-05465-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Revised: 10/04/2021] [Accepted: 10/15/2021] [Indexed: 10/19/2022] Open
Abstract
PURPOSE The purpose of this study is to document clinical outcomes of 2 posterior chamber phakic intraocular lenses with a central hole, the implantable contact lens (IPCL V2.0) and the Visian implantable collamer lens V4c (ICL), in myopic and myopic-astigmatic patients. METHODS Retrospective study comprising 111 IPCL (60 toric) and 106 ICL implantations (59 toric) with a follow-up of 3 months to 2 years. Primary outcome was uncorrected distance visual acuity (UDVA) improvement; secondary outcomes were changes in corrected distance visual acuity (CDVA), and complications. RESULTS At 3 months postoperatively, 76% of plano targeted eyes in the IPCL group and 83% of eyes in the ICL group had a UDVA of 20/20 or better. Ninety-six percent of IPCL implanted eyes and 94% of ICL implanted eyes had a postoperative UDVA within 1 line of preoperative CDVA. One eye lost one line of CDVA after IPCL implantation, and no lines were lost after ICL implantation; 33.7% of IPCL eyes and 40.6% of ICL eyes gained at least 1 line of CDVA. Cataract extraction (none because of anterior subcapsular opacification) was performed after 4 ICL implantations, none after IPCL implantation. Endothelial cell loss was mild with both pIOLs. Mean IOP was not clinically significantly affected at 3 months or thereafter. CONCLUSIONS We observed equally excellent (statistically not different) results with the IPCL and ICL for the correction of myopia and myopic astigmatism, at least up to 2 years post implantation. Longer follow-up is needed to determine the stability of these results especially with the IPCL.
Collapse
|
19
|
Long term efficacy and safety profiles following posterior chamber phakic intraocular lens implantation in eyes with ≥ 10-year follow-up. J Cataract Refract Surg 2021; 48:813-818. [PMID: 34670948 DOI: 10.1097/j.jcrs.0000000000000848] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Accepted: 10/13/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE Evaluate long-term efficacy, safety, predictability and stability of a posterior chamber phakic intraocular lens (Visian ICL) in eyes with ≥10-year follow-up. SETTING Instituto de Microcirugía Ocular, Barcelona, Spain. DESIGN Retrospective study. METHODS Eyes undergoing ICL implantation from 2008-2011 with ≥10-year follow-up were included. Variables analyzed were: preoperative, 1-month, 1-year, 5-years and last follow-up uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, spherical equivalent (SE), endothelial cell count (ECC) and intraocular pressure (IOP). Descriptive statistics were performed and results reported following the Standard for Reporting Refractive Surgery Outcomes. RESULTS 45 eyes (26 patients) were analyzed, mean follow-up 11.35 ± 1.30 years. Mean preoperative SE was -10.06 ± 3.40D and mean preoperative cylinder -1.55 ± 1.45D. At last follow-up, efficacy and safety indices were 0.79 and 1.12, respectively. In total, 32 (71%) eyes achieved an UDVA of ≥20/40. 22 (49%) eyes gained ≥1 line of CDVA, and 2 (4%) eyes lost ≥2 lines of CDVA. At final follow-up, 19 (42%) and 29 (64%) eyes were within ±0.50D and ±1.00D of attempted SE correction, respectively. 31 (69%) eyes had ≤1.00D of postoperative astigmatism and 29 (74%) eyes were within ±15° from the intended correction axis. At the last visit, a statistically significant myopic progression of -0.75 ± 1.20D was observed (p=0.01). ECC loss at last follow-up was 9.85 ± 11.35%. IOP remained stable. There were no intraoperative complications. 3 eyes (7%) developed cataract after 10 years. CONCLUSIONS Long-term results demonstrate that ICL is effective, predictable, stable and safe.
Collapse
|
20
|
Kim BK, Chung YT. Comparison of clinical outcomes of implantable collamer lens implantation with and without use of an ophthalmic viscosurgical device. J Cataract Refract Surg 2021; 47:198-203. [PMID: 32925657 DOI: 10.1097/j.jcrs.0000000000000417] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 08/13/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE To compare the clinical efficacy of posterior chamber phakic implantable collamer lens (ICL) implantation with and without the use of an ophthalmic viscosurgical device (OVD). SETTING Onnuri Eye Hospital, Jeonju, Jeollabuk-do, South Korea. DESIGN Retrospective case series. METHODS Included were patients who underwent ICL implantation with the use of an OVD (OVD group) and patients who underwent ICL implantation without the use of an OVD (hydro group). Refractive error, endothelial cell density (ECD), intraocular pressure (IOP), vault, and adverse events were evaluated at 1 day, 1 week, 1 month, and 3 months postoperatively. The IOP and vault were checked 1 hour postoperatively, and the surgical time was recorded. RESULTS The OVD group comprised 54 eyes of 27 patients and the hydro group 49 eyes of 25 patients. There were no significant preoperative differences between the 2 groups. At 1 hour postoperatively, the IOP was significantly higher in the OVD group (P < .001); however, there was no significant difference in IOP between the 2 groups at other follow-up timepoints. Surgical time was significantly shorter for the hydro group (P = .032). There was no statistically significant difference in vault, ECD, or refractive error between the 2 groups during the 3-month follow-up period. No adverse events were observed. CONCLUSIONS ICL implantation without the use of an OVD was safe and effective. The advantages of this technique included a short surgical time, prevention of early postoperative IOP spikes, and cost savings due to OVD elimination.
Collapse
Affiliation(s)
- Bu Ki Kim
- From the Onuuri Smile Eye Clinic (Kim), Seoul, Onnuri Eye Hospital (Chung), Jeollabuk-do, South Korea
| | | |
Collapse
|
21
|
Long-term efficacy and safety results after iris-fixated foldable phakic intraocular lens for myopia and astigmatism: 6-year follow-up. J Cataract Refract Surg 2021; 47:211-220. [PMID: 32925647 DOI: 10.1097/j.jcrs.0000000000000419] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 08/04/2020] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate the long-term efficacy and safety of iris-fixated foldable phakic intraocular lenses (pIOLs) for the management of myopia and astigmatism after 6-year follow-up. SETTING Ophthalmology Department, Hospital Braga, Portugal. DESIGN Retrospective cohort study. METHODS Patients included underwent iris-fixated foldable Artiflex pIOL implantation between January 2010 and December 2013. Follow-up evaluations were performed 6 months postoperatively and every 12 months until 72 months. Preoperative and follow-up data on uncorrected and corrected distance visual acuity (CDVA), manifest refraction, endothelial cell density (ECD), and anterior chamber depth (ACD) were analyzed. RESULTS A total of 177 eyes of 98 patients with a mean age of 32.33 ± 7.13 years were analyzed. There was a statistically significant improvement in CDVA from 0.09 ± 0.02 logMAR preoperatively to 0.04 ± 0.02 logMAR (P < .0001) at 6 years postoperatively. The spherical equivalent demonstrated a statistically significant improvement from -9.50 ± 2.93 diopters (D) to -0.41 ± 0.45 D at 6 years. At 72 months, the efficacy and safety indexes were 0.94 and 1.15, respectively. A mean loss of 31.77 cells/mm2 (1.19%) was observed each year until the sixth year. The overall mean ECD loss after correction for the physiological loss was 3.02% after 6 years. No correlations were observed between the mean ECD loss and the preoperative ACD. CONCLUSIONS The Artiflex pIOL was a safe, effective, and a stable option to correct myopia. A mean ECD loss of 3.02% was observed over 6 years. No pIOL was explanted due to corneal decompensation.
Collapse
|
22
|
Cerpa Manito S, Sánchez Trancón A, Torrado Sierra O, Baptista AM, Serra PM. Biometric and ICL-related risk factors associated to sub-optimal vaults in eyes implanted with implantable collamer lenses. EYE AND VISION 2021; 8:26. [PMID: 34225809 PMCID: PMC8256545 DOI: 10.1186/s40662-021-00250-6] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 05/30/2021] [Indexed: 12/05/2022]
Abstract
Background To identify biometric and implantable collamer lens (ICL)-related risk factors associated with sub-optimal postoperative vault in eyes implanted with phakic ICL. Methods This study reports a retrospective case series of the first operated eye in 360 patients implanted with myopic spherical or toric ICL. Preoperatively, white-to-white (WTW), central keratometry (Kc) and central corneal thickness (CCT) were measured using the Pentacam. Anterior-segment optical coherence tomography (AS-OCT, Visante) was applied preoperatively for measuring the horizontal anterior-chamber angle-to-angle distance (ATA), internal anterior chamber depth (ACD), crystalline lens rise (CLR), anterior-chamber angle (ACA) and postoperatively the vault. Eyes were divided into three vault groups: low (LVG: ≤ 250 μm), optimal (OVG: > 250 and < 1000 μm) and high (HVG: ≥ 1000 μm). Multinomial logistic regression (MLR) was used to find the sub-optimal vault predictors. Results MLR showed that CLR, ICL size minus the ATA (ICL size-ATA), age, ICL spherical equivalent (ICLSE) and ICL size as contributing factors for sub-optimal vaults (pseudo-R2 = 0.40). Increased CLR (OR: 1.01, CI: 1.00–1.01) and less myopic ICLSE (OR: 1.22, CI: 1.07–1.40) were risk factors for low vaults. Larger ICL size-ATA (OR: 41.29, CI: 10.57–161.22) and the 13.7 mm ICL (OR: 7.08, CI: 3.16–15.89) were risk factors for high vaults, whereas less myopic ICLSE (OR: 0.85, CI: 0.76–0.95) and older age (OR: 0.92, CI: 0.88–0.98) were protective factors. Conclusion High CLR and low ICLSE were the major risk factors in eyes presenting low vaults. In the opposite direction, ICL size-ATA was the major contributor for high vaults. This relationship was more critical in higher myopic ICLSE, younger eyes and when 13.7 mm ICL were used. The findings show that factors influencing the vault have differentiated weight of influence depending on the type of vault (low, optimal or high). Supplementary Information The online version contains supplementary material available at 10.1186/s40662-021-00250-6.
Collapse
Affiliation(s)
- Santiago Cerpa Manito
- Research and Development Department, Ophthalmology Clinic Vista Sánchez Trancón, Building Tecnolaser, Room 14 Calle La Violeta, 06005, Badajoz, Spain
| | - Angel Sánchez Trancón
- Research and Development Department, Ophthalmology Clinic Vista Sánchez Trancón, Building Tecnolaser, Room 14 Calle La Violeta, 06005, Badajoz, Spain
| | - Oscar Torrado Sierra
- Research and Development Department, Ophthalmology Clinic Vista Sánchez Trancón, Building Tecnolaser, Room 14 Calle La Violeta, 06005, Badajoz, Spain
| | | | - Pedro Miguel Serra
- Research and Development Department, Ophthalmology Clinic Vista Sánchez Trancón, Building Tecnolaser, Room 14 Calle La Violeta, 06005, Badajoz, Spain. .,Optics and Optometry Department, Instituto Superior de Educação e Ciências, Lisbon, Portugal.
| |
Collapse
|
23
|
Kamiya K, Ryu IH, Yoo TK, Kim JS, Lee IS, Kim JK, Ando W, Shoji N, Yamauchi T, Tabuchi H. Prediction of Phakic Intraocular Lens Vault Using Machine Learning of Anterior Segment Optical Coherence Tomography Metrics. Am J Ophthalmol 2021; 226:90-99. [PMID: 33577789 DOI: 10.1016/j.ajo.2021.02.006] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Revised: 02/05/2021] [Accepted: 02/06/2021] [Indexed: 11/30/2022]
Abstract
PURPOSE To compare the achieved vault using the conventional manufacturer's nomogram and the predicted vault using machine learning, in a large cohort of eyes undergoing posterior chamber phakic intraocular lens (EVO implantable collamer lens [ICL]; STAAR Surgical) implantation. DESIGN Reliability and validity assessment and comparison. METHODS Our study comprised a total of 1,745 eyes of 1,745 consecutive patients (mean age ± standard deviation, 26.2 ± 6.8 years) undergoing ICL implantation. At 1 month postoperatively, we quantitatively measured the actual vault, and compared it with the predicted vault using machine leaning of anterior segment optical coherence tomography metrics. RESULTS All machine learning methods, such as support vector regressor (SVR), gradient boost regressor (GBR), random forest regressor (RFR), and linear regressor (LR), showed significantly less mean absolute error and higher percentages of eyes within 50-200 µm of the targeted ICL vault than the conventional nomogram (P < .001). The RFR provided the lowest mean absolute errors and the highest percentages of eyes within 50 to 200 µm, followed by the GBR, the LR, and the SVR (P < .01). CONCLUSIONS Machine learning of the preoperative anterior segment optical coherence tomography metrics, especially the RFR, provided significantly higher predictability of the ICL vault than the conventional manufacturer's nomogram, suggesting that it will become an aid for predicting the ICL vault and subsequently selecting the proper ICL size in daily practice.
Collapse
Affiliation(s)
| | - Ik Hee Ryu
- Kitasato University, Kanagawa, Japan; B&VIIT Eye Center, Seoul, South Korea
| | - Tae Keun Yoo
- Kitasato University, Kanagawa, Japan; B&VIIT Eye Center, Seoul, South Korea; Department of Ophthalmology, Aerospace Medical Center, Republic of Korea Air Force, Cheongju, South Korea
| | - Jung Sub Kim
- Kitasato University, Kanagawa, Japan; B&VIIT Eye Center, Seoul, South Korea
| | - In Sik Lee
- Kitasato University, Kanagawa, Japan; B&VIIT Eye Center, Seoul, South Korea
| | - Jin Kook Kim
- Kitasato University, Kanagawa, Japan; B&VIIT Eye Center, Seoul, South Korea
| | - Wakako Ando
- the Department of Ophthalmology, School of Medicine
| | | | | | - Hitoshi Tabuchi
- Department of Ophthalmology, Tsukazaki Hospital, Hyogo, Japan
| |
Collapse
|
24
|
Jabbour S, Bower KS. Three-Year Outcomes of Implantable Collamer Lens Followed by Excimer Laser Enhancement ("Bioptics") in the Treatment of High Myopic Astigmatism. Clin Ophthalmol 2021; 15:635-643. [PMID: 33623364 PMCID: PMC7896759 DOI: 10.2147/opth.s283888] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Accepted: 01/18/2021] [Indexed: 11/29/2022] Open
Abstract
Purpose Describe three-year outcomes of spherical implantable Collamer lens (ICL) followed by excimer laser enhancement (bioptics) in eyes with high myopic astigmatism. Patients and Methods Retrospective case series of thirty-four cases that underwent bioptics enhancement at the Johns Hopkins Wilmer Eye Institute. All eyes had a preoperative sphere of −6.00 D or more with a cylinder of at least 2.00 D. Uncorrected and corrected distance visual acuity (UDVA and CDVA), manifest spherical equivalent refraction (MSE), ICL vault measurements and central corneal thickness (CCT) were collected. Endothelial cell counts (ECC), root mean square (RMS) of higher order aberrations (HOAs), adverse events and subsequent surgeries were also assessed. Results All patients had a minimum follow-up of 3 years. Preoperative UDVA was 2.29 ± 0.46 logMAR and improved to 0.03 ± 0.23 logMAR at 3 years (p<0.05). MSE was −12.30 ± 4.05 preoperatively and changed to −0.21 ± 0.46 at 3 years (p<0.05). The efficacy and safety indices were 1.28 ± 0.32 and 1.47 ± 0.27 at 3 years post-enhancement. HOA did not significantly change throughout the follow-up (p<0.05). Endothelial cell loss at 12 months was calculated at 5.7%. Two eyes required ICL exchange due to vault-related issues. Conclusion Bioptics offered excellent long-term safe, predictable, and efficient outcomes for high myopic astigmatism and can be considered an option if toric ICL is not available. Results confirm that wavefront-guided photoablation remains an excellent option to manage residual refractive error after phakic IOL.
Collapse
Affiliation(s)
- Samir Jabbour
- The Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Kraig S Bower
- The Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| |
Collapse
|
25
|
Visual acuity, refractive error, and regression outcomes in 169 children with high myopia who were implanted with Ophtec-Artisan or Visian phakic IOLs. J AAPOS 2021; 25:27.e1-27.e8. [PMID: 33621682 DOI: 10.1016/j.jaapos.2020.09.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 09/02/2020] [Accepted: 09/07/2020] [Indexed: 11/24/2022]
Abstract
PURPOSE To analyze outcomes in a large cohort of spectacle-aversive children with high myopia who were treated by implantation of the Ophtec-Artisan or Visian phakic intraocular lens (pIOL). METHODS Outcome data were collated retrospectively in 78 children (115 eyes) implanted with the Ophtec-Artisan iris-enclaved anterior chamber pIOL and 91 children (154 eyes) implanted with the Visian ICL (intraocular collamer lens) sulcus pIOL. All children had difficulties with spectacle or contact lens wear. Mean age at surgery was 9.9 years; mean follow-up was 3.9 years (range, 0.6-14.1 years). RESULTS A total of 248 of 269 eyes (92%) were corrected to within ± 0.5 D of their target value. Spherical correction averaged 12.3 ± 1.0 D. Refractive spherical regression was -0.04 D/year at last follow-up. Uncorrected distance visual acuity improved from an average logMAR 1.8 to 0.4; corrected distance visual acuity improved an average 0.3 logMAR. Of the treated children, 68% had a gain in binocular fusion. Neurobehavioral and/or visuomotor comorbidities were present in 87% of children. Five eyes (2%) developed retinal detachment an average 6 years after implantation. Nine eyes (3%) implanted with the Ophtec-Artisan pIOL required repositioning after trauma. CONCLUSIONS Implantation of pIOLs in children is an effective method for correcting high myopia in spectacle noncompliant children. Rates of myopic regression after pIOL surgery are substantially lower than those reported for children treated by excimer laser photorefractive keratectomy (PRK). The prevalence of major complications was relatively low in this high-risk population.
Collapse
|
26
|
Hu R, Xu W, Huang B, Wang X. Ex-PRESS shunt implantation for intractable glaucoma with posterior chamber phakic intraocular lens: a case report. BMC Ophthalmol 2021; 21:20. [PMID: 33413216 PMCID: PMC7791721 DOI: 10.1186/s12886-020-01784-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Accepted: 12/21/2020] [Indexed: 11/17/2022] Open
Abstract
Background Implantation of the posterior chamber phakic intraocular lens has been widely performed to correct high and extreme myopia. Chronic intraocular pressure (IOP) elevation may occur in its late postoperative period. For medically uncontrolled cases, surgical treatment is necessary, and benefits should be weighed against risks when determining whether to remove the lens. Case presentation A 32-year-old man with extremely high myopia presented with progressive blurred vision and medically uncontrolled IOP in the right eye. His past ocular history was significant for bilateral implantable collamer lens (ICL) implantation ten years ago. On ophthalmic examination, the ICL was well placed with a vault height of 456 µm in the right eye. The anterior chamber angles were open but narrow, and mild to moderate trabecular pigmentation was noted. Ex-PRESS glaucoma filtration surgery without ICL removal was performed to control IOP. During surgery, an Ex-PRESS P50 shunt was inserted into the anterior chamber via the front edge of the blue-grey transition zone between the sclera and cornea. Transient hypotony and shallow anterior chamber occurred in the first week after surgery, along with an ICL tilt towards the cornea with reduced vault height. No other complications related to either the ICL or the Ex-PRESS shunt were noted. IOP remained stable at 12 ~ 14 mmHg at the first 3-month follow-up. Conclusions Ex-PRESS glaucoma filtration surgery might be a safe and effective alternative treatment for intractable glaucoma with high myopia and ICL implantation. Careful assessment of the ICL position and anterior chamber angle is necessary to plan the appropriate surgical procedure. A postoperative shallow anterior chamber may result in ICL dislocation.
Collapse
Affiliation(s)
- Rongrong Hu
- Department of Ophthalmology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Wei Xu
- Department of Ophthalmology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Baishuang Huang
- Department of Ophthalmology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Xiaoyu Wang
- Department of Ophthalmology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
| |
Collapse
|
27
|
Ando W, Kamiya K, Hayakawa H, Takahashi M, Shoji N. Comparison of Phakic Intraocular Lens Vault Using Conventional Nomogram and Prediction Formulas. J Clin Med 2020; 9:jcm9124090. [PMID: 33352917 PMCID: PMC7765914 DOI: 10.3390/jcm9124090] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 12/12/2020] [Accepted: 12/16/2020] [Indexed: 10/25/2022] Open
Abstract
This study aimed to compare the achieved vault using a manufacturer's nomogram and the predicted vault using the currently available prediction formulas after posterior chamber phakic intraocular lens (EVO Implantable Collamer Lens; ICL, STAAR Surgical) implantation. We included 200 eyes of 100 consecutive patients (mean age ± standard deviation, 34.3 ± 7.8 years) undergoing ICL implantation with a central hole. Three months postoperatively, we quantitatively measured the actual vault, and we compared it with the predicted vault using anterior segment optical coherence tomography (CASIA 2, Tomey). The agreement rate of the recommended ICL size using the manufacturer's nomogram, the NK formula, and the KS formula was 50.0%. The achieved vault was 477.1 ± 263.7 µm, which was significantly smaller than the predicted vaults of 551.2 ± 335.1 and 606.4 ± 212.2 µm, using the NK and KS formulas, respectively (Dunnett test, p = 0.014, p < 0.001). The achieved vault was not significantly different from the predicted vault using the NK or KS formula (p = 0.386, p = 0.157) when selecting a 12.1 mm ICL size. It was not significantly different from the predicted vault using the NK formula (p = 0.962), but it was significantly smaller than that using the KS formula (p = 0.033) when selecting a 12.6 mm size. It was significantly smaller than the predicted vault using the NK and KS formulas (p < 0.001) when selecting 13.2 mm size. The total agreement rate of the recommended ICL size was approximately 50%. The predicted ICL vault tended to overestimate the actual ICL vault, especially when selecting a larger ICL size.
Collapse
Affiliation(s)
- Wakako Ando
- Department of Ophthalmology, School of Medicine, Kitasato University, Kanagawa 252-0374, Japan; (W.A.); (H.H.); (M.T.); (N.S.)
| | - Kazutaka Kamiya
- Visual Physiology, School of Allied Health Sciences, Kitasato University, Kanagawa 252-0373, Japan
- Correspondence: ; Tel.: +81-42-778-8464; Fax: +81-42-778-2357
| | - Hideki Hayakawa
- Department of Ophthalmology, School of Medicine, Kitasato University, Kanagawa 252-0374, Japan; (W.A.); (H.H.); (M.T.); (N.S.)
| | - Masahide Takahashi
- Department of Ophthalmology, School of Medicine, Kitasato University, Kanagawa 252-0374, Japan; (W.A.); (H.H.); (M.T.); (N.S.)
| | - Nobuyuki Shoji
- Department of Ophthalmology, School of Medicine, Kitasato University, Kanagawa 252-0374, Japan; (W.A.); (H.H.); (M.T.); (N.S.)
| |
Collapse
|
28
|
Etiology and outcomes of current posterior chamber phakic intraocular lens extraction. Sci Rep 2020; 10:21686. [PMID: 33303807 PMCID: PMC7730447 DOI: 10.1038/s41598-020-78661-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Accepted: 11/18/2020] [Indexed: 12/12/2022] Open
Abstract
This study was aimed to review the etiology and the outcomes of current posterior chamber phakic intraocular lens (Visian ICL, STAAR Surgical) extraction. This review comprised 770 eyes of 403 consecutive patients undergoing ICL extraction. We evaluated prevalence, etiology, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), predictability, and patient satisfaction. ICL extraction was required in 8 of 770 (1.0%) eyes. The most common reason was the progression of the pre-existing cataract formation in 5 eyes (63%), followed by residual refractive errors in 3 eyes (38%). Of the 7 eyes targeted for emmetropia, 7 (100%) and 6 (86%) achieved UDVAs of 20/40 and 20/20 or better, respectively. Three eyes (38%) showed no change in CDVA, 3 eyes (38%) gained 1 line, 2 eyes (25%) gained 3 or more lines. 88% and 100% were within ± 0.5 and 1.0 diopter (D), respectively, of the targeted correction. Patient satisfaction improved significantly, from 3.0 ± 1.4 preoperatively, to 8.0 ± 2.4 postoperatively. No vision-threatening complications occurred. ICL extraction was required in approximately 1% of ICL-implanted eyes. Visual and refractive outcomes were good, and patient satisfaction was overall high, even in ICL-extracted eyes.
Collapse
|
29
|
Zhou T, Jiang H, Wang Y, Xie C, Xia J, Shen Y. Comparison of anterior chamber angle changes following phakic intraocular lens with and without a central hole implantation for moderate to high myopic eyes. Medicine (Baltimore) 2020; 99:e23434. [PMID: 33285737 PMCID: PMC7717800 DOI: 10.1097/md.0000000000023434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
The aim of this study was to compare the anterior chamber angle changes after implantation of phakic intraocular lens with and without a central hole for moderate to high myopic eyes in Chinese people.This study enrolled 106 eyes of 54 people with intraocular lens V4 implantation and 105 eyes of 53 people with intraocular lens V4c implantation. Postoperative vault, intraocular pressure, and anterior chamber angle changes were assessed using noncontract tonometer and ultrasound biomicroscope, respectively, at 1, 3, 6, and 12months after the surgery.There were no significant differences (all P > .05) between the 2 groups in the depth of the central vault, intraocular pressure, or the width of anterior chamber angle at any time point post-surgery. The anterior chamber angle width in degree had a baseline of 54.40 ± 10.51 in V4c group, and decreased to 27.80 ± 5.62, 26.95 ± 5.56, 27.32 ± 5.66, 27.04 ± 5.47 at 1, 3, 6, and 12 months post-surgery, respectively. Mean preoperative value of 50.62 ± 11.77 decreased to 27.28 ± 6.53, 26.82 ± 6.03, 26.61 ± 5.80, 26.83 ± 5.76 at 1, 3, 6, 12 months, respectively, in V4 group. It had sufficient evidence (P < .001) that anterior chamber angle will narrow done after surgery, but there were no statistically significant differences within groups at any time point after surgery.The anterior chamber angle changes of the V4c group was essentially equivalent to that of conventional V4 group, although implantation of both models will lead to the decrease in anterior chamber angle width.
Collapse
|
30
|
Chaitanya SR, Anitha V, Ravindran M, Ghorpade A, Rengappa R, Uduman MS. Safety and efficacy of toric implantable collamer lens V4c model - A retrospective South Indian study. Indian J Ophthalmol 2020; 68:3006-3011. [PMID: 33229687 PMCID: PMC7856968 DOI: 10.4103/ijo.ijo_1492_20] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Purpose: The aim of this study was to evaluate the safety, efficacy, and complications of V4c Toric implantable collamer Lens (TICL) implantation for myopic astigmatism in the south Indian population. Methods: In this retrospective observational case series, a total of 109 eyes of 67 patients who underwent V4c TICL implantation (ICL, V4C Staar Surgical, Nidau, Switzerland) between January 2012 and August 2019 were studied with a minimum follow-up period of 6 months (mean 24 months). The main outcome measures were objective and subjective refraction, uncorrected distance visual acuity, corrected distance visual acuity (CDVA), safety, predictability, adverse events, and postoperative complications. Results: At 6 months, mean manifest refractive spherical equivalent (SE) decreased from - 10.90 ± 3.7D preoperatively to - 0.02 ± 0.13D postoperatively (P < 0.001) and mean cylinder decreased from - 2.3 ± 1.3 D preoperatively to - 0.04 ± 0.2 D postoperatively (P < 0.001). Postoperatively, SE within ± 0.5 D and ± 1.0 D of attempted correction were achieved in 96.3 (105 eyes) and 100% (109 eyes), respectively. Manifest refractive cylinder within ± 0.5 D and ± 1.0 D of attempted correction were achieved in 97.2 (106 eyes) and 100% (109 eyes), respectively. Sixty-two percent (68 eyes) showed no change in CDVA postoperatively, and no eye had lost lines of CDVA. The safety index was 1.12, and the efficacy index was 1.10. Complications were seen in two eyes (1.8%) due to high postoperative vault requiring secondary surgical interventions. Conclusion: V4c TICL is a highly effective, safe, and predictable option in treating myopic astigmatism with excellent improvement in vision and spectacle independence.
Collapse
Affiliation(s)
- S Ravi Chaitanya
- Fellow in Cornea and External Diseases, Aravind Eye Hospitals and Post Graduate Institute, Tirunelveli, Tamil Nadu, India
| | - Venugopal Anitha
- HOD, Cornea and Refractive Services, Aravind Eye Hospitals and Post Graduate Institute, Tirunelveli, Tamil Nadu, India
| | - Meenakshi Ravindran
- HOD, Paediatric and Strabismus Services, Aravind Eye Hospitals and Post Graduate Institute, Tirunelveli, Tamil Nadu, India
| | - Aditya Ghorpade
- Consultant, Cornea and External Diseases, Aravind Eye Hospitals and Post Graduate Institute, Tirunelveli, Tamil Nadu, India
| | - Ramakrishnan Rengappa
- Prof of Ophthalmology, Glaucoma Services, Aravind Eye Hospitals and Post Graduate Institute, Tirunelveli, Tamil Nadu, India
| | - Mahammed Sithiq Uduman
- Statistics, Aravind Eye Hospitals and Post Graduate Institute, Tirunelveli, Tamil Nadu, India
| |
Collapse
|
31
|
Kato S, Shimizu K, Igarashi A. Assessment of low-vault cases with an implantable collamer lens. PLoS One 2020; 15:e0241814. [PMID: 33147267 PMCID: PMC7641440 DOI: 10.1371/journal.pone.0241814] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Accepted: 10/20/2020] [Indexed: 11/27/2022] Open
Abstract
This study aimed to examine clinical results in low-vault eyes after implementation of a Hole implantable collamer lens (KS-AquaPORT™, STAAR Surgical Company) in terms of visual outcomes and complications over a one-year follow-up period. This was a retrospective cohort study of subjects who underwent Hole implantable collamer lens surgery at Sanno Hospital, exhibited low vault, and were followed up for 1 year. Patients were included if they met the following criteria: 20≤ age ≤55 years; stable refraction ≥6 months; -1.0 to -20.0 diopters of myopia; endothelial cell density ≥1800 cells/mm2; and no history of ocular surgery, progressive corneal degeneration, cataract, glaucoma, or uveitis. Main outcome measurements were the safety and efficacy indices, predictability, and vault. Values were indicated as the mean ± standard deviation. Subjects included 16 patients (age: 38 ± 8 years; 6 males; 25 eyes). Toric lenses were utilized for 10 eyes. Implantable collamer lens size was 12.1, 12.6, and 13.2 mm for 18, 6, and 1 eye(s), respectively. One year postoperatively, the safety index was 1.07; for 22 eyes with a target refraction of that of emmetropic eyes, the efficacy index was 0.90; and 96% of eyes were within ± 0.50 diopters of attempted versus achieved spherical equivalent correction. Postoperative vault was 142 ± 60 μm. One year postoperatively, no additional surgery was required for rotation of toric implantable collamer lens, and no advanced cataracts, increased intraocular pressure, or decreased endothelial cells were observed. In conclusion, Hole implantable collamer lens yielded satisfactory visual outcomes and no postoperative complications for low-vault eyes, suggesting its suitability for such cases.
Collapse
Affiliation(s)
- Sayaka Kato
- Eye Center, Sanno Hospital, Tokyo, Japan
- * E-mail:
| | | | | |
Collapse
|
32
|
Nakamura T, Isogai N, Kojima T, Yoshida Y, Sugiyama Y, Tanaka Y, Ichikawa K. Long-term In Vivo Stability of Posterior Chamber Phakic Intraocular Lens: Properties and Light Transmission Characteristics of Explants. Am J Ophthalmol 2020; 219:295-302. [PMID: 32622670 DOI: 10.1016/j.ajo.2020.06.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 06/19/2020] [Accepted: 06/21/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE To evaluate the in vivo durability of the surface and optical properties of the implantable Collamer lens (ICL). DESIGN Retrospective case series. METHODS We included patients who developed cataracts after having undergone ICL implantation from March 2003 to May 2014 and underwent ICL explantation followed by cataract surgery from March 2017 to December 2019 at the Nagoya Eye Clinic. ICL explants were submitted to Chukyo Medical Co, Ltd (Nagoya City, Japan) for laboratory analysis using ultraviolet-visible light spectroscopy, light microscopy (LM), and scanning electron microscopy. Patients' demographic and clinical data were collected and reviewed. RESULTS Thirteen eyes from 10 patients were studied. The average age at ICL explantation was 50.5 ± 8.5 years (range, 34.5-66.3 years). The average length of ICL stay in the eye (from implantation to explantation) was 10.5 ± 2.7 years (range, 4.4-13.7 years). No opacification or coloring of the ICL explants was observed by LM. The ICL explants showed almost the same light transmittance as that of unused ICLs. Scanning electron microscopy revealed no irregularities at the surface of the center and periphery of the optic and haptic footplate. The positioning holes did not show any deposition. CONCLUSION The ICLs remained in-eye for >10 years without any deterioration in the surface and optical properties of the ICL, despite their contact with the ciliary body and iris tissues and the continuous interaction with the aqueous humor components. The present study shows long-term in vivo stability of the ICL.
Collapse
|
33
|
Ghoreishi M, Kashfi A, Peyman M, Mohammadinia M. Comparison of Toric Implantable Collamer Lens and Toric Artiflex Phakic IOLs in Terms of Visual Outcome: a Paired Contralateral Eye Study. Am J Ophthalmol 2020; 219:186-194. [PMID: 32621900 DOI: 10.1016/j.ajo.2020.06.021] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Revised: 06/14/2020] [Accepted: 06/15/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE This study sought to compare the postoperative visual outcomes of toric implantable collamer lens (T-ICL) with toric Artiflex (T-Artiflex) lenses. DESIGN Alternating treatment, contralateral eye matched clinical study. METHODS This study compared 82 eyes of 41 patients with T-ICL lenses in one eye and toric Artiflex implantation in the contralateral eye to correct myopic astigmatism. Safety, efficacy, predictability, astigmatic vector changes, contrast sensitivity, endothelial cell count, and possible adverse events were assessed at least 12 months postoperatively. RESULTS After a mean follow-up of 12 months, the safety index was mean 1.40 ± 0.70 in the T-ICL group and 1.20 ± 0.21 in the T-Artiflex group. Furthermore, their mean efficacy indexes were 1.24 ± 0.42 and 1.08 ± 0.23, respectively (P = .029). A total of 39 eyes (95%) in the T-ICL group and 41 eyes (100%) in the T-Artiflex group were within ±1.00 diopter (D) of emmetropia and 33 eyes (80%) and 34 eyes (83%) were within ±0.5 D of emmetropia, respectively. Vector analysis revealed mean index of success as large as 0.25 ± 0.22 in the T-ICL group and 0.24 ± 0.15 in the T-Artiflex group. Postoperative contrast sensitivities were equal in both groups under mesopic conditions for any given spatial frequency. There was an endothelial loss of 2.18% and 1.95% in the T-ICL and T-Artiflex groups, respectively. There were no significant complications in any of the groups. CONCLUSIONS Both lenses showed promising results in terms of safety, efficacy, and predictability for correction of myopic astigmatism. As shown in this paired-eye study, most outcomes were almost identical, and neither of these lenses were clinically superior to the other.
Collapse
|
34
|
Zhang J, He F, Liu Y, Fan X. Implantable collamer lens with a central hole for residual refractive error correction after corneal refractive surgery. Exp Ther Med 2020; 20:160. [PMID: 33093898 PMCID: PMC7571336 DOI: 10.3892/etm.2020.9289] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 09/11/2020] [Indexed: 11/06/2022] Open
Abstract
The present study aimed to assess the visual and refractive outcomes of an implantable collamer lens with a central hole (ICL V4c) for residual refractive error correction after corneal refractive surgery in individuals with myopia. A total of 16 eyes of eight consecutive patients with myopia undergoing ICL V4c implantation after corneal refractive surgery were investigated. The uncorrected visual acuity (VA) and best-corrected VA were examined prior to surgery and at 1, 3 and 6 months after surgery. The post-operative values of the modulation transfer function (MTF) cutoff frequency, Strehl ratio (SR), objective scattering index (OSI) and Optical Quality Analysis System (OQAS) values (OVs) were quantitatively assessed using an OQAS. At 6 months after surgery, the mean uncorrected LogMAR VA was 0.06±0.10 and the values had improved in 100% of the eyes. The mean MTF cutoff frequency, SR, OSI, OV 100%, OV 20% and OV 9%, were 31.294±4.321 cycles/degree, 0.187±0.039, 1.399±0.274, 1.066±0.261, 0.748±0.287 and 0.509±0.229, respectively. In conclusion, ICL V4c implantation for the correction of residual refractive error after corneal refractive surgery appeared feasible and safe and also had an excellent optical performance. However, long-term changes in visual quality require further investigation.
Collapse
Affiliation(s)
- Jing Zhang
- Department of Ophthalmology, Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P.R. China
| | - Fanglin He
- Department of Ophthalmology, Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P.R. China
| | - Yan Liu
- Department of Ophthalmology, Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P.R. China
| | - Xianqun Fan
- Department of Ophthalmology, Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P.R. China
| |
Collapse
|
35
|
Martínez-Plaza E, López-Miguel A, Fernández I, Blázquez-Arauzo F, Maldonado MJ. Effect of central hole location in phakic intraocular lenses on visual function under progressive headlight glare sources. J Cataract Refract Surg 2020; 45:1591-1596. [PMID: 31706513 DOI: 10.1016/j.jcrs.2019.06.022] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2018] [Revised: 06/07/2019] [Accepted: 06/17/2019] [Indexed: 11/17/2022]
Abstract
PURPOSE To analyze the effect of the central hole location in the V4c implantable collamer lens (ICL) on the quality of vision, including progressive headlight glare simulation and quality of life. SETTING IOBA-Eye Institute, Valladolid, Spain. DESIGN Case series. METHODS The central hole location was determined by slitlamp and dual Scheimpflug imaging for 6 months or more postoperatively. The visual acuity, mesopic contrast sensitivity, halogen glare contrast sensitivity, xenon glare contrast sensitivity, photostress recovery time after glare, de Boer scale, and Quality of Life Impact of Refractive Correction (QIRC) questionnaire results were evaluated. Multiple regression models were used to analyze the effect of the central hole location on parameters using the pupil center and visual axis as references based on Cartesian and polar coordinates. RESULTS The safety index was 1.13 and the efficacy index, 1.12. Under all testing circumstances, central hole decentration did not affect the visual acuity or contrast sensitivity. With the visual axis as a reference, worse QIRC values were associated with greater upward central hole displacement (P = .03) and a lower polar angle value (P = .008); also, halogen glare discomfort was greater with a higher radius (P = .04). Using the pupil center as a reference, greater nasal central hole decentration was associated with longer xenon glare photostress recovery time (P = .002). CONCLUSIONS Implantation of the ICL with a central hole yielded excellent visual outcomes, even under increasing glare sources, regardless of the hole's location. However, hole decentration might affect patient-perceived quality of life, bothersome halogen glare, and longer xenon glare photostress recovery time. Such complaints after the early postoperative period might be managed with discrete ICL centration if the central hole is decentered upward or nasally.
Collapse
Affiliation(s)
- Elena Martínez-Plaza
- Instituto de Oftalmobiología Aplicada, Universidad de Valladolid, Valladolid, Spain
| | - Alberto López-Miguel
- Instituto de Oftalmobiología Aplicada, Universidad de Valladolid, Valladolid, Spain; Red Temática de Investigación Colaborativa en Oftalmología, Instituto de Salud Carlos III, Madrid, Spain.
| | - Itziar Fernández
- Instituto de Oftalmobiología Aplicada, Universidad de Valladolid, Valladolid, Spain; Networking Research Center on Bioengineering Biomaterials and Nanomedicine, Valladolid, Spain
| | | | - Miguel J Maldonado
- Instituto de Oftalmobiología Aplicada, Universidad de Valladolid, Valladolid, Spain; Red Temática de Investigación Colaborativa en Oftalmología, Instituto de Salud Carlos III, Madrid, Spain
| |
Collapse
|
36
|
Effect of Angle Opening Parameters on Corneal Endothelial Cell Density and Intraocular Pressure after Posterior Chamber Phakic Intraocular Lens Implantation. J Clin Med 2020; 9:jcm9092704. [PMID: 32825643 PMCID: PMC7565728 DOI: 10.3390/jcm9092704] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 08/14/2020] [Accepted: 08/18/2020] [Indexed: 11/30/2022] Open
Abstract
This study aimed to investigate the time courses of angle opening parameters and the relationships of these with the corneal endothelial cell density (ECD) and the intraocular pressure (IOP) after posterior chamber phakic intraocular lens (Visian ICLTM, STAAR Surgical) implantation. We evaluated 116 eyes of 59 consecutive patients (mean age ± standard deviation, 34.0 ± 8.8 years) who underwent V5 implantable collamer lens (ICL) implantation. Preoperatively and 1 day, 1 week, and 1, 3, and 18 months postoperatively, we quantitatively measured the angle opening distance at 500 µm (AOD500), the trabecular-iris space area (TISA500), and the trabecular iris angle (TIA500), using anterior segment optical coherence tomography (CASIA 2, Tomey), and assessed the relationships of these measurements with ECD and IOP in ICL-implanted eyes. All angle parameters (AOD500, TISA500, and TIA500) significantly decreased 1 day postoperatively but remained stable thereafter. At 18 months postoperatively, we found no significant correlations of the angle parameters with ECD (Pearson correlation coefficient r = −0.108, p = 0.249 for AOD500; r = −0.162, p = 0.083 for TISA500; r = −0.022, p = 0.815 for TIA500) or between the angle parameters and IOP (r = −0.106, p = 0.256 for AOD500; r = −0.021, p = 0.826 for TISA500; r = −0.018, p = 0.850 for TIA500). The angle opening metrics significantly decreased immediately after ICL implantation but remained stable thereafter. Narrowing of the angle did not significantly affect ECD or IOP in ICL-implanted eyes during the 18-month postoperative period.
Collapse
|
37
|
Vargas V, Alió JL, Barraquer RI, D' Antin JC, García C, Duch F, Balgos J, Alió Del Barrio JL. Safety and visual outcomes following posterior chamber phakic intraocular lens bilensectomy. EYE AND VISION 2020; 7:34. [PMID: 32626790 PMCID: PMC7329535 DOI: 10.1186/s40662-020-00200-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Accepted: 05/28/2020] [Indexed: 12/13/2022]
Abstract
Background To evaluate the safety, efficacy, refractive outcomes and causes for bilensectomy (phakic intraocular lens – pIOL – explantation with cataract surgery and pseudophakic intraocular lens implantation) in patients previously implanted with posterior chamber pIOLs. Methods This multi-center retrospective study included 87 eyes of 55 patients who underwent bilensectomy for posterior chamber pIOL with a follow up time of 12 months. The uncorrected and best corrected distance visual acuities (UDVA, CDVA), endothelial cell density before and after bilensectomy were assessed, as well as the cause of bilensectomy and intra or postoperative complications. Results There was a statistically significant improvement in uncorrected and best corrected visual acuities after bilensectomy (p = 0.00). The main reason for bilensectomy was cataract development (93.1% of the cases), followed by miscalculation of lens size, and corneal edema. The endothelial cell count remained stable without a statistically significant change after surgery (p = 0.67). The refractive efficacy index was 0.8, none of the patients lost lines of CDVA after surgery, 73% of the patients were within ±1 D (spherical equivalent) of the target refraction. Intraoperative complications were one posterior capsule rupture with the intraocular lens (IOL) implanted in the sulcus, and 3 eyes required the use of pupil expanders for adequate pupil dilation. Postoperatively, one eye developed retinal detachment. The three pIOLs models explanted were the Implantable Collamer Lens (ICL), Implantable Phakic Contact Lens (IPCL) and the Phakic Refractive Lens (PRL). Conclusions Good safety and visual outcomes were observed 1 year after bilensectomy for posterior chamber phakic intraocular lenses (PC pIOLs). There were few intra and postoperative complications and there was no significant endothelial cell loss after the bilensectomy procedure.
Collapse
Affiliation(s)
| | - Jorge L Alió
- Vissum Instituto Oftalmológico de Alicante, Alicante, Spain.,Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain
| | - Rafael I Barraquer
- Institut Universitari Barraquer, Universitat Autònoma de Barcelona, Barcelona, Spain.,Centro de Oftalmología Barraquer, Barcelona, Spain.,Universitat Internacional de Catalunya, Barcelona, Spain
| | - Justin Christopher D' Antin
- Institut Universitari Barraquer, Universitat Autònoma de Barcelona, Barcelona, Spain.,Centro de Oftalmología Barraquer, Barcelona, Spain
| | | | - Francisco Duch
- Instituto Catalán de Retina (ICR) unidad de Cirugía Refractiva, Barcelona, Spain
| | - Joan Balgos
- Vissum Instituto Oftalmológico de Alicante, Alicante, Spain
| | - Jorge L Alió Del Barrio
- Vissum Instituto Oftalmológico de Alicante, Alicante, Spain.,Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain
| |
Collapse
|
38
|
Zhang J, He FL, Liu Y, Fan XQ. Comparison of choroidal thickness in high myopic eyes after FS-LASIK versus implantable collamer lens implantation with swept-source optical coherence tomography. Int J Ophthalmol 2020; 13:773-781. [PMID: 32420225 DOI: 10.18240/ijo.2020.05.12] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Accepted: 03/15/2020] [Indexed: 01/22/2023] Open
Abstract
AIM To investigate the changes in choroidal thickness (CT) in high myopic eyes after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) surgery or central hole implantable collamer lens (ICL V4c) implantation using swept-source optical coherence tomography (SS-OCT). METHODS We examined the right eyes of 116 patients with high myopia who were candidates for FS-LASIK surgery and ICL implantation. Sixty eyes underwent ICL V4c implantation and 56 eyes were subjected to FS-LASIK surgery. The CT was measured with SS-OCT. All data were recorded preoperatively and 2h, 1wk, 1 and 3mo postoperatively. Other demographic information was collected, including age, sex, uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), spherical equivalent (SE), intraocular pressure (IOP) and axial length (AL). RESULTS The UCVA improved in both groups and showed no significant differences between groups. There also were no significant differences between the two groups in postoperative BCVA and SE (P=0.581 and 0.203, respectively). The foveal CTs, inner nasal and outer nasal CTs were significantly thicker at 2h postoperatively in both groups (P<0.05) but returned to baseline levels in 1wk; after 1mo, no significant differences were found relative to the preoperative values. At 3mo in each group, nine regions showed variations in the CT as compared with preoperative thickening, but only the foveal and nasal area CTs preoperative differences were statistically significant (P<0.05). In addition, there was no significant difference in 9 regions of CT between the two groups at all follow-up times (P>0.05). CONCLUSION The CTs after ICL implantation and FS-LASIK surgery are significantly thicker than those before operation, especially in the foveal and nasal areas, but there is no significant difference between the two methods.
Collapse
Affiliation(s)
- Jing Zhang
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Disease and Ocular Oncology, Shanghai 200011, China
| | - Fang-Lin He
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Disease and Ocular Oncology, Shanghai 200011, China
| | - Yan Liu
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Disease and Ocular Oncology, Shanghai 200011, China
| | - Xian-Qun Fan
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Disease and Ocular Oncology, Shanghai 200011, China
| |
Collapse
|
39
|
Anterior chamber angle width, central vault and intraocular pressure changes after 12 months of Visian collamer lens implantation. Int Ophthalmol 2020; 40:2047-2053. [DOI: 10.1007/s10792-020-01381-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Accepted: 04/10/2020] [Indexed: 12/30/2022]
|
40
|
Yaşa D, Köse B, Ağca A. Rotational Stability of a New Posterior Chamber Toric Phakic Intraocular Lens. J Ophthalmol 2020; 2020:1624632. [PMID: 32351717 PMCID: PMC7171658 DOI: 10.1155/2020/1624632] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2019] [Accepted: 03/12/2020] [Indexed: 11/17/2022] Open
Abstract
PURPOSE To evaluate the refractive results and rotational stability of Eyecryl toric phakic intraocular lens (pIOL). METHODS In this retrospective single-surgeon case series, manifest refraction, visual acuities, endothelial cell density (ECD), and pIOL rotation were evaluated over 6 months. RESULTS 43 eyes from 23 patients were included. At 6 months, the SE was within ±0.50 D of emmetropia in 30 (70%) eyes and within ±1.00 D of emmetropia in 39 (91%) eyes. The efficacy and safety indices were 1.25 ± 0.38 and 1.41 ± 0.34, respectively. Mean ECD was 2719 ± 296 cells/mm2 at the preoperative visit and 2779.42 ± 422 cells/mm2 at the 6-month visit (p > 0.05). The mean value of absolute axis orientation error was 4.95 ± 5.28°. Mean absolute change in axis orientation between visits was less than 3° for all visit intervals. Ninety percent or more of lenses were found to rotate 5° or less between all visit intervals. None of the patients experienced a vision-threatening complication, and no patient required secondary IOL repositioning. CONCLUSION The pIOL appears to effectively reduce subjective manifest astigmatism and provide good visual acuity. Its position was found to be stable throughout the follow-up.
Collapse
Affiliation(s)
- Dilek Yaşa
- Beyoğlu Eye Training and Research Hospital, Bereketzade Mah, No. 2, Beyoglu, Istanbul, Turkey
| | - Bülent Köse
- Aritmi Osmangazi Hospital, Ulu Mah, Ulubatlı Hasan Bulvarı, No. 48-62, Bursa, Turkey
| | - Alper Ağca
- Beyoğlu Eye Training and Research Hospital, Bereketzade Mah, No. 2, Beyoglu, Istanbul, Turkey
| |
Collapse
|
41
|
Qin Q, Wu Z, Bao L, Chen H, Yang L, He Z, Huang Z. Evaluation of visual quality after EVO-ICL implantation for hypermyopia: An observational study. Medicine (Baltimore) 2019; 98:e17677. [PMID: 31689784 PMCID: PMC6946539 DOI: 10.1097/md.0000000000017677] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
The purpose of this retrospective study was to evaluate the visual quality, objective scattering index, aberration, etc after Implantable Collamer Lens with center hole (EVO-ICL) implantation to treat patients with hypermyopia (diopter > -10 D).A total of 30 eyes underwent EVO-ICL implantation. The uncorrected distance visual acuity (UDVA), best-corrected visual acuity (BCVA), equivalent spherical degree, aberration, visual quality parameters, and corneal endothelial cell density were compared preoperative and postoperative. Fill in the National Eye Institute Refractive Error Quality of Life Instrument-42 before and after surgery.The modulation transfer function (MTF), Optical Quality Analysis System (OQAS) II values (OV 100%, 20%, 9%), and Stahl ratio 1 and 3 months after surgery were higher than the respective preoperative values. The objective scatter index value increased 1 week after surgery, but decreased 1 and 3 months after surgery compared with the preoperative values. Total aberration (TA), total low-order aberration (tLOAs), and defocus decreased at 1 week and 3 months after EVO-ICL implantation. Total high-order aberration (tHOAs) and spherical aberration were significantly increased 1 week after surgery and decreased 3 months after surgery, and the difference was statistically significant. Astigmatism, coma, and clover were not significantly different in each time period. TA, tLOAs, tHOAs, defocus, and spherical aberration were higher at 1 week than 3 months after surgery. At 3 months after surgery, the scores of the patients' NEI-RQL-42 scale were all improved except that the glare was lower than that before surgery. There was no significant difference in the density of corneal endothelial cells before and 3 months after surgery.For patients with hypermyopia, the postoperative subjective and objective visual quality of EVO-ICL implantation was better than preoperative.
Collapse
Affiliation(s)
- Qin Qin
- Department of Ophthalmology, Nanjing Drum Tower Hospital, Affiliated to Nanjing University Medical School
- Department of Ophthalmology, Nanjing Drum Tower Hospital Clinical College of Nanjing Medical University
- Department of Ophthalmology, Jinling Medical School of Nanjing Medical University
- Department of Ophthalmology, Jinling Hospital
| | - Zhengcan Wu
- Department of Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu Province, China
| | - Lianyun Bao
- Department of Ophthalmology, Nanjing Drum Tower Hospital, Affiliated to Nanjing University Medical School
| | - Hui Chen
- Department of Ophthalmology, Nanjing Drum Tower Hospital, Affiliated to Nanjing University Medical School
| | - Liping Yang
- Department of Ophthalmology, Jinling Medical School of Nanjing Medical University
- Department of Ophthalmology, Jinling Hospital
| | - Zifang He
- Department of Ophthalmology, Nanjing Drum Tower Hospital, Affiliated to Nanjing University Medical School
| | - Zhenping Huang
- Department of Ophthalmology, Jinling Medical School of Nanjing Medical University
- Department of Ophthalmology, Jinling Hospital
| |
Collapse
|
42
|
Nakamura T, Isogai N, Kojima T, Yoshida Y, Sugiyama Y. Posterior Chamber Phakic Intraocular Lens Implantation for the Correction of Myopia and Myopic Astigmatism: A Retrospective 10-Year Follow-up Study. Am J Ophthalmol 2019; 206:1-10. [PMID: 31078536 DOI: 10.1016/j.ajo.2019.04.024] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Revised: 04/10/2019] [Accepted: 04/23/2019] [Indexed: 11/16/2022]
Abstract
PURPOSE To assess the 10-year clinical outcomes of implantable collamer lens (ICL) implantation for myopia and astigmatism. DESIGN Retrospective observational case series. METHODS This study included 114 eyes of 61 patients who underwent ICL implantation for correction of myopia and myopic astigmatism. We assessed the safety, efficacy, predictability, stability, and adverse events preoperatively, at 6 months (106 eyes) and 1 (94 eyes), 3 (58 eyes), 5 (65 eyes), 8 (89 eyes), and 10 (70 eyes) years postoperatively. Only the eyes with clinical data available at each follow-up time were analyzed. RESULTS The mean logMAR uncorrected and corrected distance visual acuities were -0.01 ± 0.24 and -0.18 ± 0.07 at 10 years postsurgery. The mean indices for safety and efficacy were 0.88 ± 0.15 and 0.66 ± 0.26, respectively. At 10 years postsurgery, 71.4% and 87.1% of the eyes were within 0.5 and 1.0 diopters (D), respectively, of the attempted spherical equivalent correction. The mean intraocular pressure was 13.1 ± 2.4 mmHg preoperatively and 13.1 ± 2.9 mmHg at 10 years postoperatively. The mean endothelial cell loss was 5.3% at 10 years postsurgery. Twelve of 114 eyes (10.5%) developed anterior subcapsular cataract during 5-10 years' follow-up; among these, 4 eyes (3.5%) were symptomatic and ICL explantation and phacoemulsification surgery were performed. No vision-threatening complications occurred during the observation period. CONCLUSION ICL implantation offered good overall outcomes in all measures of safety, efficacy, predictability, and stability for the correction of myopia and myopic astigmatism throughout a long-term follow-up period of 10 years.
Collapse
Affiliation(s)
| | | | - Takashi Kojima
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | | | | |
Collapse
|
43
|
Sachdev GS, Singh S, Ramamurthy S, Rajpal N, Dandapani R. Comparative analysis of clinical outcomes between two types of posterior chamber phakic intraocular lenses for correction of myopia and myopic astigmatism. Indian J Ophthalmol 2019; 67:1061-1065. [PMID: 31238411 PMCID: PMC6611309 DOI: 10.4103/ijo.ijo_1501_18] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Purpose: To compare clinical outcomes following implantation of two types of posterior chamber phakic intraocular lenses: Visian™ Implantable Collamer Lens with Centraflow (ICL, V4C Staar Surgical, Nidau, Switzerland) and Implantable Phakic Contact Lens (IPCL, V1, Caregroup Sight Solution, India) for the correction of myopia and myopic astigmatism. Methods: This retrospective case series included eyes which underwent phakic intraocular lens implantation with a minimum follow-up period of 1 year. Visual outcomes including safety, efficacy, refractive predictability, and stability were compared at 1 week and at 1, 6, and 12 months’ postoperative visit. Complications and adverse events were analyzed. Results: The study included 119 and 203 eyes in the IPCL and ICL groups, respectively. At 1-year postoperative visit, median corrected distance visual acuity was 0.10 (interquartile range [IQR] 0,0.10) and 0 (IQR 0,0) in the IPCL and ICL cohorts, respectively (P = 0.066). An uncorrected visual acuity of 20/32 or better was achieved in 86.5% and 88.67% of the eyes, respectively (P = 0.574). Ninety and 94% of the eyes achieved a postoperative manifest spherical equivalent within ± 0.5D (P = 0.169, χ2 test). Three eyes (2.52%) in the IPCL group versus one eye (0.49%) in the ICL group developed visually significant cataract requiring surgical intervention (P = 0.113). No vision-threatening complications were noted in either cohort. The mean follow-up period was 94.69 ± 32.45 and 102.67 ± 61.82 weeks, respectively. Conclusion: Both groups demonstrated similar efficacy and safety profile. The IPCL is an effective and economically viable option for the correction of myopia.
Collapse
Affiliation(s)
| | - Shivangi Singh
- Refractive Services, The Eye Foundation, RS Puram, Coimbatore, Tamil Nadu, India
| | - Shreyas Ramamurthy
- Refractive Services, The Eye Foundation, RS Puram, Coimbatore, Tamil Nadu, India
| | - Narayan Rajpal
- Refractive Services, The Eye Foundation, RS Puram, Coimbatore, Tamil Nadu, India
| | - Ramamurthy Dandapani
- Refractive Services, The Eye Foundation, RS Puram, Coimbatore, Tamil Nadu, India
| |
Collapse
|
44
|
Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography. J Cataract Refract Surg 2019; 45:1099-1104. [PMID: 31174990 DOI: 10.1016/j.jcrs.2019.02.020] [Citation(s) in RCA: 71] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 02/08/2019] [Accepted: 02/14/2019] [Indexed: 11/23/2022]
Abstract
PURPOSE To determine whether vault measurements after placement of a hole implantable collamer lens (hole ICL) (KS-AquaPORT) can be predicted by angle-to-angle (ATA) and white-to-white (WTW) measurements obtained with anterior segment optical coherence tomography (AS-OCT). SETTING Sanno Hospital, Tokyo, Japan. DESIGN Retrospective case series. METHODS Eyes were observed for 3 months after hole ICL implantation for myopia or myopic astigmatism. Central vault, ATA, and WTW measurements were obtained before and after surgery using the swept-source AS-OCT CASIA2 system. RESULTS The study included 44 eyes (23 patients). The mean patient age and preoperative spherical equivalent, ATA, and WTW values were 36.2 years ± 8.8 (SD), -6.23 ± 3.41 diopters (D), 12.03 ± 0.40 mm, and 11.72 ± 0.40 mm, respectively. The safety index and efficacy index 3 months postoperatively were 1.13 ± 0.21 and 0.91 ± 0.30, respectively. Regarding predictability, 93.2% of eyes were within ±0.50 D of the attempted correction and all eyes were within ±1.00 D. The reproducibility coefficients for the ATA distance and WTW distance were 0.998 and 0.960, respectively. The mean postoperative central vault was 491.6 ± 189.5 μm. There was a significant correlation between postoperative vault and the ICL size and ATA distance (Spearman rank correlation coefficient r = 0.59, P < .001) but not between the ICL size and WTW distance (r = 0.27, P = .08). CONCLUSION The ATA measurements had higher reproducibility than the WTW measurements on AS-OCT, making it is a more important predictor of postoperative vault.
Collapse
|
45
|
Niu L, Miao H, Han T, Ding L, Wang X, Zhou X. Visual outcomes of Visian ICL implantation for high myopia in patients with shallow anterior chamber depth. BMC Ophthalmol 2019; 19:121. [PMID: 31142292 PMCID: PMC6542118 DOI: 10.1186/s12886-019-1132-z] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Accepted: 05/20/2019] [Indexed: 11/30/2022] Open
Abstract
Background High myopia with shallow anterior chamber depth (ACD less than 2.8 mm) is not rare. This observational study aims to evaluate visual outcomes after implantation of the Visian Implantable Collamer Lens with a central hole (ICL V4c) in these patients. Methods A prospective cohort of consecutive 51 eyes of 31 patients (20 to 42 years old) was followed for at least 12 months (average 15.35 ± 4.90 months, rangers from 12 to 25 months). The preoperative ACD was 2.74 ± 0.04 mm (2.65 to 2.79 mm). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), intraocular pressure (IOP), manifest refraction, vault, and endothelial cell density (ECD) were measured during the follow-ups after surgery. Results All surgeries were performed safely and no complication was observed during the follow-ups. At the last follow-up, the safety index (postoperative CDVA / preoperative CDVA) was 1.33 ± 0.60 and the efficacy index (postoperative UDVA / preoperative CDVA) was 1.14 ± 0.54. After the surgery, no eye had decreased CDVA and 59% (30 eyes) of the eyes gained at least one line. Forty-seven eyes (92%) were within ±1.0 D and 35 eyes (69%) were within ±0.5 D of the attempted refraction. The mean postoperative vault was 380.00 ± 152.84 μm (90 to 700 μm). The ECD was reduced by 8.38 ± 0.06% as compared to the preoperative value (p < 0.001). No significant change was observed in IOP (p = 0.061) at the last follow-up. Ultrasound Biomicroscopy (UBM) showed none of the eyes had trabecular-iris angle closed. Conclusions In this prospective observational study, ICL V4c implantation in patients with high myopia and shallow ACD achieved satisfying and stable visual outcomes. Its long-term safety and stability require further investigation. Trial registration This trial was retrospectively registered on 05/08/2018 under the number (ChiCTR1800017594).
Collapse
Affiliation(s)
- Lingling Niu
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, 83 Fen Yang Road, Shanghai, 200031, China.,Key NHC Key Laboratory of Myopia (Fudan University), 83 Fen Yang Road, Shanghai, 200031, China.,Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fen Yang Road, Shanghai, 200031, China.,Shanghai Research Center of Ophthalmology and Optometry, 83 Fen Yang Road, Shanghai, 200031, China
| | - Huamao Miao
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, 83 Fen Yang Road, Shanghai, 200031, China.,Key NHC Key Laboratory of Myopia (Fudan University), 83 Fen Yang Road, Shanghai, 200031, China.,Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fen Yang Road, Shanghai, 200031, China.,Shanghai Research Center of Ophthalmology and Optometry, 83 Fen Yang Road, Shanghai, 200031, China
| | - Tian Han
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, 83 Fen Yang Road, Shanghai, 200031, China.,Key NHC Key Laboratory of Myopia (Fudan University), 83 Fen Yang Road, Shanghai, 200031, China.,Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fen Yang Road, Shanghai, 200031, China.,Shanghai Research Center of Ophthalmology and Optometry, 83 Fen Yang Road, Shanghai, 200031, China
| | - Lan Ding
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, 83 Fen Yang Road, Shanghai, 200031, China.,Key NHC Key Laboratory of Myopia (Fudan University), 83 Fen Yang Road, Shanghai, 200031, China.,Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fen Yang Road, Shanghai, 200031, China.,Shanghai Research Center of Ophthalmology and Optometry, 83 Fen Yang Road, Shanghai, 200031, China
| | - Xiaoying Wang
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, 83 Fen Yang Road, Shanghai, 200031, China.,Key NHC Key Laboratory of Myopia (Fudan University), 83 Fen Yang Road, Shanghai, 200031, China.,Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fen Yang Road, Shanghai, 200031, China.,Shanghai Research Center of Ophthalmology and Optometry, 83 Fen Yang Road, Shanghai, 200031, China
| | - Xingtao Zhou
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, 83 Fen Yang Road, Shanghai, 200031, China. .,Key NHC Key Laboratory of Myopia (Fudan University), 83 Fen Yang Road, Shanghai, 200031, China. .,Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fen Yang Road, Shanghai, 200031, China. .,Shanghai Research Center of Ophthalmology and Optometry, 83 Fen Yang Road, Shanghai, 200031, China.
| |
Collapse
|
46
|
Qin Q, Bao L, Yang L, He Z, Huang Z. Comparison of visual quality after EVO-ICL implantation and SMILE to select the appropriate surgical method for high myopia. BMC Ophthalmol 2019; 19:21. [PMID: 30732575 PMCID: PMC6367781 DOI: 10.1186/s12886-019-1029-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Accepted: 01/04/2019] [Indexed: 11/11/2022] Open
Abstract
Background This study sought to compare the visual quality between intraocular collamer lens (EVO-ICL) implantation and small-incision lenticule extraction (SMILE) and determine the appropriate surgical method to treat patients with high myopia (− 6.25 to − 10 D). Methods A total of 48 eyes underwent EVO-ICL implantation and another 48 eyes underwent SMILE. The uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BCVA) and equivalent spherical degree were compared across the SMILE (− 6.25 to − 10 D) and EVO-ICL (− 6.25 to − 10 D) implantation groups. Preoperative and postoperative visual quality parameters were compared between and within groups. Results The OQAS II values (OV 100%) one week and one month after surgery and the modulation transfer function (MTF), OV 20% and OV 9% values one week after surgery in the SMILE group were lower than the respective preoperative values. The objective scatter index (OSI) value increased one week as well as one month after surgery compared with the preoperative values. The MTF cut-off value of the SMILE group was lower than that of the EVO-ICL implantation group three months after surgery. Conclusions For patients with high myopia, the postoperative visual quality of EVO- ICL implantation was slightly better than that of SMILE.
Collapse
Affiliation(s)
- Qin Qin
- Department of Ophthalmology, Nanjing Drum Tower Hospital Clinical College of Nanjing Medical University, Nanjing, 210008, Jiangsu, China.,Department of Ophthalmology, Nanjing Drum Tower Hospital, Affiliated to Nanjing University Medical School, Nanjing, 210008, China.,Department of Ophthalmology, Jinling Medical School of Nanjing Medical University, No. 305 East Zhongshan Road, Nanjing, 210002, Jiangsu Province, China.,Department of Ophthalmology, Jinling Hospital, No. 305 East Zhongshan Road, Nanjing, 210002, Jiangsu Province, China
| | - Lianyun Bao
- Department of Ophthalmology, Nanjing Drum Tower Hospital, Affiliated to Nanjing University Medical School, Nanjing, 210008, China
| | - Liping Yang
- Department of Ophthalmology, Jinling Medical School of Nanjing Medical University, No. 305 East Zhongshan Road, Nanjing, 210002, Jiangsu Province, China.,Department of Ophthalmology, Jinling Hospital, No. 305 East Zhongshan Road, Nanjing, 210002, Jiangsu Province, China
| | - Zifang He
- Department of Ophthalmology, Nanjing Drum Tower Hospital, Affiliated to Nanjing University Medical School, Nanjing, 210008, China
| | - Zhenping Huang
- Department of Ophthalmology, Jinling Medical School of Nanjing Medical University, No. 305 East Zhongshan Road, Nanjing, 210002, Jiangsu Province, China. .,Department of Ophthalmology, Jinling Hospital, No. 305 East Zhongshan Road, Nanjing, 210002, Jiangsu Province, China.
| |
Collapse
|
47
|
Vasavada V, Srivastava S, Vasavada SA, Sudhalkar A, Vasavada AR, Vasavada VA. Safety and Efficacy of a New Phakic Posterior Chamber IOL for Correction of Myopia: 3 Years of Follow-up. J Refract Surg 2019; 34:817-823. [PMID: 30540364 DOI: 10.3928/1081597x-20181105-01] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2018] [Accepted: 11/02/2018] [Indexed: 01/30/2023]
Abstract
PURPOSE To evaluate the outcomes of a new posterior chamber phakic intraocular lens (IPCL; Care Group, Baroda, India) to correct myopia. METHODS This prospective, observational case series included 30 eyes undergoing implantation of the IPCL for high myopia (> -8.00 diopters [D]). Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, vault, endothelial cell loss, and adverse events were evaluated 3 years after implantation of the IPCL for high myopia. RESULTS The mean spherical equivalent decreased from -16.50 ± 5.62 D preoperatively to -0.89 ± 1.27 D at 3 years. The mean UDVA and CDVA were 0.38 ± 0.21 and 0.24 ± 0.09 logMAR. No eye lost any lines and 49% of eyes gained one line or more of CDVA. One eye (3.3%) developed anterior subcapsular cataract, but did not require cataract surgery at 3 years of follow-up. Two eyes (6.6%) developed a mild transient increase in intraocular pressure, which required topical medication only for 3 months. The percentage of endothelial cell loss at 3 years was 9.73% ± 6.72%. The IPCL vault tended to reduce with time, from a mean of 626.66 ± 188.98 μm at 1 month to 540.22 ± 210.76 μm at 3 years. No vision-threatening complications occurred. CONCLUSIONS Implantation of the new posterior chamber phakic IOL is an effective alternative to correct high myopia, showing good outcomes at 3 years. [J Refract Surg. 2018;34(12):817-823.].
Collapse
|
48
|
Sachdev G, Ramamurthy D. Long-term safety of posterior chamber implantable phakic contact lens for the correction of myopia. Clin Ophthalmol 2019; 13:137-142. [PMID: 30662257 PMCID: PMC6327895 DOI: 10.2147/opth.s185304] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Purpose To review the safety of the implantable phakic contact lens (IPCL V1, Caregroup Sight Solutions, India) for correction of myopia and myopic astigmatism. Methods Retrospective interventional case series including 134 eyes which underwent IPCL implantation for correction of myopia and myopic astigmatism at a tertiary eye care hospital in South India. Intraoperative and postoperative complications were analyzed. The following parameters were analyzed at preoperative and 1, 6 and 12 month postoperative visits: visual acuity (in logMAR) and manifest refraction, slit lamp bio microscopy, dilated fundus examination, IOP and endothelial cell density measurement. Results No intraoperative complications were noted. Cataract was the most common postoperative complication, wherein three eyes (2.2%) underwent observation for visually insignificant anterior subcapsular cataract and one eye (0.7%) required surgical intervention. Four eyes developed transient increased IOP due to steroid response (3 eyes) and pupillary block glaucoma (1 eye). The endothelial cell loss noted over a 1-year follow-up was 2.01%±4.12% (P=0.71). One eye developed hypopyon on the third postoperative day, which resolved subsequently with an unaided vision of 20/20. No vision threatening complications were noted. The mean follow-up in the cohort was 25.66±16.45 months. Conclusion The IPCL is a safe and effective treatment modality for correction of myopia and myopic astigmatism.
Collapse
|
49
|
Subramanian S, Vadivelu S, Babu MA, Meenakshi B, Santhosh J. A study on the safety and efficacy of posterior chamber phakic intraocular lens (refractive implantable lens) in high myopia. TNOA JOURNAL OF OPHTHALMIC SCIENCE AND RESEARCH 2019. [DOI: 10.4103/tjosr.tjosr_45_19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
50
|
Li Z, Xu Z, Wang Y, Liu Q, Chen B. Implantable collamer lens surgery in patients with primary iris and/or ciliary body cysts. BMC Ophthalmol 2018; 18:287. [PMID: 30400839 PMCID: PMC6218971 DOI: 10.1186/s12886-018-0935-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2018] [Accepted: 10/09/2018] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND The prevalence of primary iris and/or ciliary body cysts is common in myopia, though asymptomatic in nearly all cases. It's a very valuable thing to study the clinical safety and reliability of implantable collamer lens (ICL) surgery in patients with primary iris and/or ciliary body cysts. METHODS A total of 108 patients (201 eyes) were included in this retrospective study. All eyes had been implanted with V4c implantable collamer lens (ICLV4c). According to the eyes with or without primary iris and/or ciliary body cysts, all eyes were divided into two groups. We observed preoperative and postoperative uncorrected distance visual acuity (UDVA), corrected distance visual acuity)(CDVA), intra-ocular pressure(IOP), anterior chamber volume(ACV), anterior chamber depth(ACD), trabecular-iris angle (TIA), angle opening distance at 500 μm (AOD500),vertical central distance between the corneal endothelium and the front surface of ICL(CE-ICL), and the central vault. The follow-up periods covered 12 months. RESULTS Among all the 201 eyes, primary iris and/or ciliary body cysts were detected in 54 eyes (26.87%),but the prevalence was account to 36.11%(18males,21females).There were 30 eyes (55.56%) with unilateral single cyst, 12 eyes (22.22%) with unilateral double cysts, 12 eyes (22.22%) eyes with unilateral multiple and/or multi-quadrants cysts, the mean size of cysts was (0.714 ± 0.149)mm(range from 0.510 to 1.075 mm).30.4% of the cysts were located at iridociliary sulcus, 65.5% in pars plicata, and 4.1% in midzonal iris, which showed a characteristic distribution pattern, with cysts found predominantly in the inferior and temporal quadrants.The postoperative size and the number of cysts showed nearly no changes. The postoperative ACV, AOD500 and TIA showed a statistical reduction in both two groups (P < 0.05), but with no statistical significant between the two groups (P > 0.05), the parameters of postoperative IOP,CE-ICL and central vault also showed the same results as which. We did not observe serious complication and IOP elevating in the whole follow-up periods. CONCLUSION Primary iris and/or ciliary body cysts are not absolutely contraindication for ICL surgery. For some single cyst smaller than 1.075 mm or single quadrant cysts located at ciliary body are rare to lead some serious complications. But, for some multiple cysts, especially multi-quadrants cysts located at iridociliary sulcus, we still should remain cautions.
Collapse
Affiliation(s)
- Zhen Li
- Department of Ophthalmology, The People’s Hospital of Leshan, 635 Wanghaoer Street, Leshan, Sichuan Province 614000 People’s Republic of China
| | - Zhike Xu
- Department of Ophthalmology, The People’s Hospital of Leshan, 635 Wanghaoer Street, Leshan, Sichuan Province 614000 People’s Republic of China
| | - Yaqin Wang
- Department of Ophthalmology, The People’s Hospital of Leshan, 635 Wanghaoer Street, Leshan, Sichuan Province 614000 People’s Republic of China
| | - Qiang Liu
- Department of Ophthalmology, The People’s Hospital of Leshan, 635 Wanghaoer Street, Leshan, Sichuan Province 614000 People’s Republic of China
| | - Bin Chen
- Department of Ophthalmology, The People’s Hospital of Leshan, 635 Wanghaoer Street, Leshan, Sichuan Province 614000 People’s Republic of China
| |
Collapse
|