1
|
Li X, Mak CM, Ai Z, Ma KW, Wong HM. Propagation and evaporation of contaminated droplets, emission and exposure in surgery environments revealed by laser visualization and numerical characterization. JOURNAL OF HAZARDOUS MATERIALS 2024; 477:135338. [PMID: 39084008 DOI: 10.1016/j.jhazmat.2024.135338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Revised: 06/24/2024] [Accepted: 07/25/2024] [Indexed: 08/02/2024]
Abstract
The contaminated liquid mixture containing mucosalivary fluid and blood would be aerosolized during medical procedures, resulting in higher-risk exposures. The novelty of this research is integrating laser visualization and numerical characterization to assess the propagation and evaporation of contaminated droplets, and the interactive effects of humidity and temperature on exposure risks will be numerically evaluated in surgery environments. The numerical model evidenced by experiments can predict the mass balance of ejection droplets, the minimum required fallow time (FT) between appointments, and the disinfection region of greatest concern. Around 98.4 % of the ejection droplet mass will be removed after the cessation of ultrasonic scaling, while the initial droplet size smaller than 72.6μm will dehydrate and become airborne. The FT recommendation of 30 min is not over-cautious, and the extended FT (range of 28-37 min) should be instituted for low temperature (20.5 °C) and high humidity levels (60 %RH). The variation of the temperature and humidity in the range for human thermal comfort has little influence on the area of the disinfection region (0.15m2) and the cut-off size (72.6μm) of droplet deposition and suspension. This research can provide scientific evidence for the guidelines of environmental conditions in surgery rooms.
Collapse
Affiliation(s)
- Xiujie Li
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Cheuk Ming Mak
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Zhengtao Ai
- Department of Building Environment and Energy, College of Civil Engineering, Hunan University, Changsha 410082, China
| | - Kuen Wai Ma
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Hai Ming Wong
- Faculty of Dentistry, The University of Hong Kong, Hong Kong, China.
| |
Collapse
|
2
|
Akhtar N, Tahir A, Abbas M, Zaman N, Qadir A, Arshad M. Temporal trends in indoor bioaerosols: implications for dental healthcare environments. INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH 2024:1-13. [PMID: 38944751 DOI: 10.1080/09603123.2024.2373173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Accepted: 06/22/2024] [Indexed: 07/01/2024]
Abstract
Antibiotic resistance, a significant public health hazard, is predicted to cause 10 million deaths worldwide by 2050. The study aimed to identify culturable bioaerosols in the indoor air of dental units in Lahore and assess their antibiotic resistance. Air samples were collected from 10 dental unit locations at different distances, with average concentrations of fungi and bacteria falling within intermediate ranges, per the Global Index of Microbial Contamination (GIMC/m3) index. The study found higher antibiotic-resistant strains in hospital dental units, particularly during winter. The most vigorous strain, S.aureus-NAJIH18, exhibited 70% resistance to ceftazidime. The research highlights the importance of quantifying microbial pollutants for evaluating their source and complexity. It suggests proactive mitigation techniques, such as focused cleaning and air filtration, to improve indoor air quality can mitigate the spread of antibiotic-resistant strains. These insights offer hope in combating the growing public health threat of antibiotic resistance.
Collapse
Affiliation(s)
- Naseem Akhtar
- Environmental Science Department, Lahore College for Women University, Lahore, Pakistan
| | - Arifa Tahir
- Environmental Science Department, Lahore College for Women University, Lahore, Pakistan
| | - Moneeza Abbas
- Environmental Science Department, Lahore College for Women University, Lahore, Pakistan
| | - Nasib Zaman
- Centre for Biotechnology & Microbiology, University of Swat, Swat, Pakistan
| | - Abdul Qadir
- College of Earth & Environmental Sciences, University of the Punjab Lahore, Lahore, Pakistan
| | - Muhammad Arshad
- Department of Basic Science, Jhang Campus, University of Veterinary and Animal Sciences, Lahore, Pakistan
| |
Collapse
|
3
|
An T, Liang Z, Chen Z, Li G. Recent progress in online detection methods of bioaerosols. FUNDAMENTAL RESEARCH 2024; 4:442-454. [PMID: 38933213 PMCID: PMC10239662 DOI: 10.1016/j.fmre.2023.05.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 04/03/2023] [Accepted: 05/03/2023] [Indexed: 10/29/2023] Open
Abstract
The aerosol transmission of coronavirus disease in 2019, along with the spread of other respiratory diseases, caused significant loss of life and property; it impressed upon us the importance of real-time bioaerosol detection. The complexity, diversity, and large spatiotemporal variability of bioaerosols and their external/internal mixing with abiotic components pose challenges for effective online bioaerosol monitoring. Traditional methods focus on directly capturing bioaerosols before subsequent time-consuming laboratory analysis such as culture-based methods, preventing the high-resolution time-based characteristics necessary for an online approach. Through a comprehensive literature assessment, this review highlights and discusses the most commonly used real-time bioaerosol monitoring techniques and the associated commercially available monitors. Methods applied in online bioaerosol monitoring, including adenosine triphosphate bioluminescence, laser/light-induced fluorescence spectroscopy, Raman spectroscopy, and bioaerosol mass spectrometry are summarized. The working principles, characteristics, sensitivities, and efficiencies of these real-time detection methods are compared to understand their responses to known particle types and to contrast their differences. Approaches developed to analyze the substantial data sets obtained by these instruments and to overcome the limitations of current real-time bioaerosol monitoring technologies are also introduced. Finally, an outlook is proposed for future instrumentation indicating a need for highly revolutionized bioaerosol detection technologies.
Collapse
Affiliation(s)
- Taicheng An
- Guangdong-Hong Kong-Macao Joint Laboratory for Contaminants Exposure and Health, Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, Institute of Environmental Health and Pollution control, Guangdong University of Technology, Guangzhou 510006, China
- Guangzhou Key Laboratory of Environmental Catalysis and Pollution Control, Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China
| | - Zhishu Liang
- Guangdong-Hong Kong-Macao Joint Laboratory for Contaminants Exposure and Health, Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, Institute of Environmental Health and Pollution control, Guangdong University of Technology, Guangzhou 510006, China
- Guangzhou Key Laboratory of Environmental Catalysis and Pollution Control, Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China
| | - Zhen Chen
- Guangdong-Hong Kong-Macao Joint Laboratory for Contaminants Exposure and Health, Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, Institute of Environmental Health and Pollution control, Guangdong University of Technology, Guangzhou 510006, China
| | - Guiying Li
- Guangdong-Hong Kong-Macao Joint Laboratory for Contaminants Exposure and Health, Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, Institute of Environmental Health and Pollution control, Guangdong University of Technology, Guangzhou 510006, China
- Guangzhou Key Laboratory of Environmental Catalysis and Pollution Control, Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China
| |
Collapse
|
4
|
Yu Y, Wu X, Sun Y. Precise control of digital dental unit to reduce aerosol and splatter production: new challenges for future epidemics. BMC Oral Health 2024; 24:213. [PMID: 38341576 PMCID: PMC10859011 DOI: 10.1186/s12903-024-03980-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 02/03/2024] [Indexed: 02/12/2024] Open
Abstract
BACKGROUND During dental procedures, critical parameters, such as cooling condition, speed of the rotary dental turbine (handpiece), and distance and angle from pollution sources, were evaluated for transmission risk of the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), simulated by spiking in a plasmid encoding a modified viral spike protein, HexaPro (S6P), in droplets and aerosols. METHODS To simulate routine operation in dental clinics, dental procedures were conducted on a dental manikin within a digital dental unit, incorporating different dental handpiece speeds and cooling conditions. The tooth model was immersed in Coomassie brilliant blue dye and was pre-coated with 100 μL water spiked-in with S6P-encoding plasmid. Furthermore, the manikin was surrounded by filter papers and Petri dishes positioned at different distances and angles. Subsequently, the filter papers and Petri dishes were collected to evaluate the aerosol splash points and the viral load of S6P-encoding plasmid in aerosols and splatters generated during the dental procedure. RESULTS Aerosol splashing generated a localized pollution area extended up to 60 cm, with heightened contamination risks concentrated within a 30 cm radius. Significant differences in aerosol splash points and viral load by different turbine handpiece speeds under any cooling condition (P < 0.05) were detected. The highest level of aerosol splash points and viral load were observed when the handpiece speed was set at 40,000 rpm. Conversely, the lowest level of aerosol splash point and viral load were found at a handpiece speed of 10,000 rpm. Moreover, the aerosol splash points with higher viral load were more prominent in the positions of the operator and assistant compared to other positions. Additionally, the position of the operator exhibited the highest viral load among all positions. CONCLUSIONS To minimize the spread of aerosol and virus in clinics, dentists are supposed to adopt the minimal viable speed of a dental handpiece with limited cooling water during dental procedures. In addition, comprehensive personal protective equipment is necessary for both dental providers and dental assistants.
Collapse
Affiliation(s)
- Yuedi Yu
- College of Dental Medicine, Columbia University, New York, NY, 10032, USA
| | - Xueling Wu
- Aaron Diamond AIDS Research Center, Columbia University Vagelos College of Physicians and Surgeons, New York, NY, 10032, USA
| | - Yang Sun
- Department of Stomatology, Zhongshan Hospital, Fudan University, No. 180 Fenglin road, Shanghai, 200032, China.
| |
Collapse
|
5
|
Martín-Quintero I, Cervera-Sabater A, Cortés-Bretón Brinkmann J, Aragoneses-Lamas JM, Flores-Fraile J, Santos-Marino J. Reduction by air purifier of particulate concentration during orthodontic procedures: a pilot study. BMC Oral Health 2024; 24:199. [PMID: 38326811 PMCID: PMC10848394 DOI: 10.1186/s12903-024-03956-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2023] [Accepted: 01/30/2024] [Indexed: 02/09/2024] Open
Abstract
BACKGROUND The SARS-CoV-2 pandemic has raised awareness of the importance of air quality. This pilot study arose from the need to reduce the concentration of particulate matter in the dental office during orthodontic procedures. To evaluate the efficacy of using an air purifier during orthodontic care in the dental office to reduce the concentration of ambient particulate matter. RESULTS Significant reductions in particle numbers were obtained for all particle sizes except the largest particles counted (10 μm) through use of the air filter. A marked association between higher humidity levels and higher particle counts was also observed. CONCLUSIONS Using an air purifier during dental care achieves a significant reduction in the concentration of ambient particles in the dental office. There is a correlation between higher relative humidity and higher particle concentration. The probability of obtaining a maximum particulate concentration level of 0.3 and 0.5 μm is 1000 times lower when using an air purifier.
Collapse
Affiliation(s)
| | - Alberto Cervera-Sabater
- Department of Dental Clinical Specialties, Faculty of Dentistry, Complutense University of Madrid, Madrid, 28049, Spain
| | - Jorge Cortés-Bretón Brinkmann
- Department of Dental Clinical Specialties, Faculty of Dentistry, Complutense University of Madrid, Madrid, 28049, Spain.
| | | | - Javier Flores-Fraile
- Department of Surgery, Faculty of Medicine, University of Salamanca, Salamanca, 37007, Spain
| | - Juan Santos-Marino
- Department of Surgery, Faculty of Medicine, University of Salamanca, Salamanca, 37007, Spain
| |
Collapse
|
6
|
Kim MJ, Kuroda M, Kobayashi Y, Yamamoto T, Aizawa T, Satoh K. Visualization of airborne droplets generated with dental handpieces and verification of the efficacy of high-volume evacuators: an in vitro study. BMC Oral Health 2023; 23:976. [PMID: 38062423 PMCID: PMC10704774 DOI: 10.1186/s12903-023-03725-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Accepted: 11/29/2023] [Indexed: 12/18/2023] Open
Abstract
BACKGROUND The COVID-19 pandemic led to concerns about the potential airborne transmission of the virus during dental procedures, but evidence of actual transmission in clinical settings was lacking. This study aimed to observe the behavior of dental sprays generated from dental rotary handpieces and to evaluate the effectiveness of high-volume evacuators (HVEs) using laser light sheets and water-sensitive papers. METHODS A dental manikin and jaw model were mounted in a dental treatment unit. Mock cutting procedures were performed on an artificial tooth on the maxillary left central incisor using an air turbine, a contra-angle electric micromotor (EM), and a 1:5 speed-up contra-angle EM (×5EM). Intraoral vacuum and extraoral vacuum (EOV) were used to verify the effectiveness of the HVEs. The dynamics and dispersal range of the dental sprays were visualized using a laser light sheet. In addition, environmental surface pollution was monitored three-dimensionally using water-sensitive papers. RESULTS Although the HVEs were effective in both the tests, the use of EOV alone increased vertical dispersal and pollution. CONCLUSIONS The use of various types of HVEs to reduce the exposure of operators and assistants to dental sprays when using dental rotary cutting instruments is beneficial. The study findings will be helpful in the event of a future pandemic caused by an emerging or re-emerging infectious disease.
Collapse
Affiliation(s)
- Min Jung Kim
- Department of Dentistry and Oral-Maxillofacial Surgery, Fujita Health University, School of Medicine, 1-98 Dengakugakubo, Kutsukake, Toyoake, Aichi, 470-1192, Japan
| | - Mana Kuroda
- Department of Dentistry and Oral-Maxillofacial Surgery, Fujita Health University, School of Medicine, 1-98 Dengakugakubo, Kutsukake, Toyoake, Aichi, 470-1192, Japan
| | - Yoshikazu Kobayashi
- Department of Dentistry and Oral-Maxillofacial Surgery, Fujita Health University, School of Medicine, 1-98 Dengakugakubo, Kutsukake, Toyoake, Aichi, 470-1192, Japan.
| | - Takahisa Yamamoto
- Department of Mechanical Engineering, National Institute of Technology, Gifu College, 2236-2 Kamimakuwa, Motosu-city, Gifu, 501-0495, Japan
| | - Takako Aizawa
- Department of Dentistry and Oral-Maxillofacial Surgery, Fujita Health University, School of Medicine, 1-98 Dengakugakubo, Kutsukake, Toyoake, Aichi, 470-1192, Japan
| | - Koji Satoh
- Department of Dentistry and Oral-Maxillofacial Surgery, Fujita Health University, School of Medicine, 1-98 Dengakugakubo, Kutsukake, Toyoake, Aichi, 470-1192, Japan
| |
Collapse
|
7
|
Finnegan M, Thach CL, Khaki S, Markey E, O’Connor DJ, Smeaton AF, Morrin A. Characterization of Volatile and Particulate Emissions from Desktop 3D Printers. SENSORS (BASEL, SWITZERLAND) 2023; 23:9660. [PMID: 38139506 PMCID: PMC10747962 DOI: 10.3390/s23249660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Revised: 11/30/2023] [Accepted: 12/04/2023] [Indexed: 12/24/2023]
Abstract
The rapid expansion of 3D printing technologies has led to increased utilization in various industries and has also become pervasive in the home environment. Although the benefits are well acknowledged, concerns have arisen regarding potential health and safety hazards associated with emissions of volatile organic compounds (VOCs) and particulates during the 3D printing process. The home environment is particularly hazardous given the lack of health and safety awareness of the typical home user. This study aims to assess the safety aspects of 3D printing of PLA and ABS filaments by investigating emissions of VOCs and particulates, characterizing their chemical and physical profiles, and evaluating potential health risks. Gas chromatography-mass spectrometry (GC-MS) was employed to profile VOC emissions, while a particle analyzer (WIBS) was used to quantify and characterize particulate emissions. Our research highlights that 3D printing processes release a wide range of VOCs, including straight and branched alkanes, benzenes, and aldehydes. Emission profiles depend on filament type but also, importantly, the brand of filament. The size, shape, and fluorescent characteristics of particle emissions were characterized for PLA-based printing emissions and found to vary depending on the filament employed. This is the first 3D printing study employing WIBS for particulate characterization, and distinct sizes and shape profiles that differ from other ambient WIBS studies were observed. The findings emphasize the importance of implementing safety measures in all 3D printing environments, including the home, such as improved ventilation, thermoplastic material, and brand selection. Additionally, our research highlights the need for further regulatory guidelines to ensure the safe use of 3D printing technologies, particularly in the home setting.
Collapse
Affiliation(s)
- Melissa Finnegan
- School of Chemical Sciences, National Centre for Sensor Research, Dublin City University, D09 DXA0 Dublin, Ireland; (M.F.); (S.K.); (D.J.O.)
- Insight SFI Research Centre for Data Analytics, Dublin City University, D09 Y5N0 Dublin, Ireland;
| | - Colleen Lee Thach
- Department of Chemistry, The University of Kansas, Lawrence, KS 66046, USA;
| | - Shirin Khaki
- School of Chemical Sciences, National Centre for Sensor Research, Dublin City University, D09 DXA0 Dublin, Ireland; (M.F.); (S.K.); (D.J.O.)
- Insight SFI Research Centre for Data Analytics, Dublin City University, D09 Y5N0 Dublin, Ireland;
| | - Emma Markey
- School of Chemical Sciences, Dublin City University, D09 Y5N0 Dublin, Ireland;
| | - David J. O’Connor
- School of Chemical Sciences, National Centre for Sensor Research, Dublin City University, D09 DXA0 Dublin, Ireland; (M.F.); (S.K.); (D.J.O.)
- Insight SFI Research Centre for Data Analytics, Dublin City University, D09 Y5N0 Dublin, Ireland;
| | - Alan F. Smeaton
- Insight SFI Research Centre for Data Analytics, Dublin City University, D09 Y5N0 Dublin, Ireland;
| | - Aoife Morrin
- School of Chemical Sciences, National Centre for Sensor Research, Dublin City University, D09 DXA0 Dublin, Ireland; (M.F.); (S.K.); (D.J.O.)
- Insight SFI Research Centre for Data Analytics, Dublin City University, D09 Y5N0 Dublin, Ireland;
| |
Collapse
|
8
|
Li YG, Li JC, Yu XY, Hu J, Li Z, Cao JC. Quantitative assessment of aerosol contamination generated during tooth grinding with a speed-increasing handpiece. J Dent 2023; 139:104631. [PMID: 37495202 DOI: 10.1016/j.jdent.2023.104631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 06/29/2023] [Accepted: 07/21/2023] [Indexed: 07/28/2023] Open
Abstract
OBJECTIVES Tooth grinding produces a significant amount of aerosol particles. The aim of this study was to quantitatively assess particle contamination produced from tooth grinding with a speed-increasing handpiece across a real-world clinical setting. METHODS All molar crowns were pretreated into cylinders with a uniform size. A novel computer-assisted numerical control system was used to parametrically study the bur speed: from 20,000 (20 K) to 200 K rpm at 20 K rpm intervals. 5-minute tooth grinding was performed in triplicate at each speed setting. Three online real-time particle counters (ORPC; TR-8301, TongrenCo.) were placed at 3 positions (0.5, 1, and 1.5 m) to evaluate particle production. All experimental instruments were controlled remotely. The data obtained were statistically analyzed using descriptive statistics and non-parametric tests (Scheirer-Ray-Hare and Kruskal-Wallis/ Dunn-Bonferroni tests, p < 0.05). RESULTS The concentration level of aerosol particles production during the grinding experiment was elevated above the control group for all conditions, and increased with bur speed at any location (the maximum peak, reaching 5.59 × 107 particles/m3, at 200 K and 1 m), with differences between conditions. The effect of speed on the increment of particles across different channels compared to the control group was statistically significant among locations (p < 0.001). CONCLUSIONS Statistically significant particle contamination was produced using a speed-increasing handpiece, but the contamination level for each experimental condition was reduced to baseline within 30 min, and most particles with a diameter greater than 1üm produced at low speeds (80 K or lower) tended to settle within 1 m. CLINICAL RELEVANCE Our study suggested that the use of a speed-increasing handpiece below 80 K and 30 min of fallow time may lead to an adequate reduction in the health effects of particle contamination.
Collapse
Affiliation(s)
- Yu-Gang Li
- School of Mechanical Engineering, Guizhou University, Guiyang, China; Guizhou Equipment Manufacturing Polytechnic, Guiyang, China
| | - Jia-Chun Li
- School of Mechanical Engineering, Guizhou University, Guiyang, China.
| | - Xiao-Yan Yu
- Guiyang Hospital of Stomatology, Guiyang, China
| | - Jie Hu
- School of Mechanical Engineering, Guizhou University, Guiyang, China
| | - Zhe Li
- School of Life Sciences, Guizhou Normal University, Guiyang, China
| | - Ji-Chao Cao
- College of Mechanical and Vehicle Engineering, Hunan University, Changsha, China
| |
Collapse
|
9
|
Kumar MS, He R, Feng L, Olin P, Chew HP, Jardine P, Anderson GC, Hong J. Particle generation and dispersion from high-speed dental drilling. Clin Oral Investig 2023; 27:5439-5448. [PMID: 37479870 DOI: 10.1007/s00784-023-05163-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 07/13/2023] [Indexed: 07/23/2023]
Abstract
OBJECTIVE To investigate the characteristics of particle generation and dispersion during dental procedure using digital inline holography (DIH) METHODS: Particles at two locations, near-field and far-field, which represent the field closer to the procedure location and within 0.5 m from the procedure location respectively, are studied using two different DIH systems. The effect of three parameters namely rotational speed, coolant flow rate, and bur angle on particle generation and dispersion are evaluated by using 10 different operating conditions. The particle characteristics at different operating conditions are estimated from the holograms using machine learning-based analysis. RESULTS The particle concentration decreased by at least two orders of magnitude between the near-field and far-field locations across the 10 different operating conditions, indicating significant dispersion of the particles. High rotational speed is found to produce a larger number of smaller particles, while lower rotational speeds generate larger particles. Coolant flow rate is found to have a greater impact on particle transport to the far-field location. Irregular shape dental particles account for 29% of total particles at far-field location, with the majority of these irregular shape particles having diameters ranging from 12 to 18 μm. CONCLUSIONS All three parameters have significant effects on particle generation and dispersion, with rotational speed having a more significant influence on particle generation at near-field and coolant flow rate playing a more important role on particle transport to the far-field. CLINICAL RELEVANCE This study provides valuable insights on particle characteristics during high-speed drilling. It can help dental professionals minimize exposure risks for themselves and patients by optimizing clinical operating conditions.
Collapse
Affiliation(s)
- M Shyam Kumar
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Ruichen He
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, USA
- Saint Anthony Falls Laboratory, University of Minnesota, Minneapolis, MN, USA
| | - Lei Feng
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, USA
- Saint Anthony Falls Laboratory, University of Minnesota, Minneapolis, MN, USA
| | - Paul Olin
- University of Minnesota School of Dentistry, Minneapolis, MN, USA
| | - Hooi Pin Chew
- University of Minnesota School of Dentistry, Minneapolis, MN, USA
| | - Paul Jardine
- University of Minnesota School of Dentistry, Minneapolis, MN, USA
| | - Gary C Anderson
- University of Minnesota School of Dentistry, Minneapolis, MN, USA
| | - Jiarong Hong
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, USA.
- Saint Anthony Falls Laboratory, University of Minnesota, Minneapolis, MN, USA.
| |
Collapse
|
10
|
Dey S, Tunio M, Boryc LC, Hodgson BD, Garcia GJM. Quantifying strategies to minimize aerosol dispersion in dental clinics. EXPERIMENTAL AND COMPUTATIONAL MULTIPHASE FLOW 2023; 5:290-303. [PMID: 37305074 PMCID: PMC10042415 DOI: 10.1007/s42757-022-0157-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 11/12/2022] [Accepted: 12/25/2022] [Indexed: 03/29/2023]
Abstract
Many dental procedures are aerosol-generating and pose a risk for the spread of airborne diseases, including COVID-19. Several aerosol mitigation strategies are available to reduce aerosol dispersion in dental clinics, such as increasing room ventilation and using extra-oral suction devices and high-efficiency particulate air (HEPA) filtration units. However, many questions remain unanswered, including what the optimal device flow rate is and how long after a patient exits the room it is safe to start treatment of the next patient. This study used computational fluid dynamics (CFD) to quantify the effectiveness of room ventilation, an HEPA filtration unit, and two extra-oral suction devices to reduce aerosols in a dental clinic. Aerosol concentration was quantified as the particulate matter under 10 µm (PM10) using the particle size distribution generated during dental drilling. The simulations considered a 15 min procedure followed by a 30 min resting period. The efficiency of aerosol mitigation strategies was quantified by the scrubbing time, defined as the amount of time required to remove 95% of the aerosol released during the dental procedure. When no aerosol mitigation strategy was applied, PM10 reached 30 µg/m3 after 15 min of dental drilling, and then declined gradually to 0.2 µg/m3 at the end of the resting period. The scrubbing time decreased from 20 to 5 min when the room ventilation increased from 6.3 to 18 air changes per hour (ACH), and decreased from 10 to 1 min when the flow rate of the HEPA filtration unit increased from 8 to 20 ACH. The CFD simulations also predicted that the extra-oral suction devices would capture 100% of the particles emanating from the patient's mouth for device flow rates above 400 L/min. In summary, this study demonstrates that aerosol mitigation strategies can effectively reduce aerosol concentrations in dental clinics, which is expected to reduce the risk of spreading COVID-19 and other airborne diseases.
Collapse
Affiliation(s)
- Shamudra Dey
- Joint Department of Biomedical Engineering, Marquette University, Medical College of Wisconsin, Milwaukee, 53226 USA
| | - Maryam Tunio
- School of Dentistry, Marquette University, Milwaukee, 53233 USA
| | - Louis C. Boryc
- School of Dentistry, Marquette University, Milwaukee, 53233 USA
| | | | - Guilherme J. M. Garcia
- Joint Department of Biomedical Engineering, Marquette University, Medical College of Wisconsin, Milwaukee, 53226 USA
| |
Collapse
|
11
|
Boccia G, Di Spirito F, D’Ambrosio F, De Caro F, Pecora D, Giorgio R, Fortino L, Longanella W, Franci G, Santella B, Amato M. Microbial Air Contamination in a Dental Setting Environment and Ultrasonic Scaling in Periodontally Healthy Subjects: An Observational Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:ijerph20032710. [PMID: 36768076 PMCID: PMC9916071 DOI: 10.3390/ijerph20032710] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 01/30/2023] [Accepted: 02/01/2023] [Indexed: 05/14/2023]
Abstract
The risk of microbial air contamination in a dental setting, especially during aerosol-generating dental procedures (AGDPs), has long been recognized, becoming even more relevant during the COVID-19 pandemic. However, individual pathogens were rarely studied, and microbial loads were measured heterogeneously, often using low-sensitivity methods. Therefore, the present study aimed to assess microbial air contamination in the dental environment, identify the microorganisms involved, and determine their count by active air sampling at the beginning (T0), during (T1), and at the end (T2) of ultrasonic scaling in systemically and periodontally healthy subjects. Air microbial contamination was detected at T0 in all samples, regardless of whether the sample was collected from patients treated first or later; predominantly Gram-positive bacteria, including Staphylococcus and Bacillus spp. and a minority of fungi, were identified. The number of bacterial colonies at T1 was higher, although the species found were similar to that found during the T0 sampling, whereby Gram-positive bacteria, mainly Streptococcus spp., were identified. Air samples collected at T2 showed a decrease in bacterial load compared to the previous sampling. Further research should investigate the levels and patterns of the microbial contamination of air, people, and the environment in dental settings via ultrasonic scaling and other AGDPs and identify the microorganisms involved to perform the procedure- and patient-related risk assessment and provide appropriate recommendations for aerosol infection control.
Collapse
Affiliation(s)
- Giovanni Boccia
- Dai Dipartimento Di Igiene Sanitaria e Medicina Valutativa U.O.C. Igiene Ospedaliera, A.O.U. San Giovanni di Dio e Ruggi D’Aragona Largo Città di Ippocrate, 84131 Salerno, Italy
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Salerno, Italy
| | - Federica Di Spirito
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Salerno, Italy
| | - Francesco D’Ambrosio
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Salerno, Italy
| | - Francesco De Caro
- Dai Dipartimento Di Igiene Sanitaria e Medicina Valutativa U.O.C. Igiene Ospedaliera, A.O.U. San Giovanni di Dio e Ruggi D’Aragona Largo Città di Ippocrate, 84131 Salerno, Italy
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Salerno, Italy
| | - Domenico Pecora
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Salerno, Italy
| | - Riccardo Giorgio
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Salerno, Italy
| | - Luigi Fortino
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Salerno, Italy
| | | | - Gianluigi Franci
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Salerno, Italy
| | - Biagio Santella
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Salerno, Italy
- Correspondence: (B.S.); (M.A.)
| | - Massimo Amato
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Salerno, Italy
- Correspondence: (B.S.); (M.A.)
| |
Collapse
|
12
|
Sheehan MJ, Vosburgh DJH, O'Shaughnessy PT, Park JH, Sotelo C. Direct-reading instruments for aerosols: A review for occupational health and safety professionals part 2: Applications. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2022; 19:706-729. [PMID: 36197433 DOI: 10.1080/15459624.2022.2132256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Direct reading instruments (DRIs) for aerosols have been used in industrial hygiene practice for many years, but their potential has not been fully realized by many occupational health and safety professionals. Although some DRIs quantify other metrics, this article will primarily focus on DRIs that measure aerosol number, size, or mass. This review addresses three applications of aerosol DRIs that occupational health and safety professionals can use to discern, characterize, and document exposure conditions and resolve aerosol-related problems in the workplace. The most common application of aerosol DRIs is the evaluation of engineering controls. Examples are provided for many types of workplaces and situations including construction, agriculture, mining, conventional manufacturing, advanced manufacturing (nanoparticle technology and additive manufacturing), and non-industrial sites. Aerosol DRIs can help identify the effectiveness of existing controls and, as needed, develop new strategies to reduce potential aerosol exposures. Aerosol concentration mapping (ACM) using DRI data can focus attention on emission sources in the workplace spatially illustrate the effectiveness of controls and constructively convey concerns to management and workers. Examples and good practices of ACM are included. Video Exposure Monitoring (VEM) is another useful technique in which video photography is synced with the concentration output of an aerosol DRI. This combination allows the occupational health and safety professional to see what tasks, environmental situations, and/or worker actions contribute to aerosol concentration and potential exposure. VEM can help identify factors responsible for temporal variations in concentration. VEM can assist with training, engage workers, convince managers about necessary remedial actions, and provide for continuous improvement of the workplace environment. Although using DRIs for control evaluation, ACM and VEM can be time-consuming, the resulting information can provide useful data to prompt needed action by employers and employees. Other barriers to adoption include privacy and security issues in some worksites. This review seeks to provide information so occupational health and safety professionals can better understand and effectively use these powerful applications of aerosol DRIs.
Collapse
Affiliation(s)
- Maura J Sheehan
- Department of Health, West Chester University, West Chester, Pennsylvania
| | - Donna J H Vosburgh
- Department of Occupational & Environmental Safety & Health, University of Wisconsin-Whitewater, Whitewater, Wisconsin
| | | | - Jae Hong Park
- School of Health Sciences, Purdue University, West Lafayette, Indiana
| | | |
Collapse
|
13
|
Markey E, Hourihane Clancy J, Martínez-Bracero M, Neeson F, Sarda-Estève R, Baisnée D, McGillicuddy EJ, Sewell G, O’Connor DJ. A Modified Spectroscopic Approach for the Real-Time Detection of Pollen and Fungal Spores at a Semi-Urban Site Using the WIBS-4+, Part I. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22228747. [PMID: 36433340 PMCID: PMC9694534 DOI: 10.3390/s22228747] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 11/08/2022] [Accepted: 11/10/2022] [Indexed: 05/19/2023]
Abstract
The real-time monitoring of primary biological aerosol particles (PBAP) such as pollen and fungal spores has received much attention in recent years as a result of their health and climatic effects. In this study, the Wideband Integrated Bioaerosol Sensor (WIBS) 4+ model was evaluated for its ability to sample and detect ambient fungal spore and pollen concentrations, compared to the traditional Hirst volumetric method. Although the determination of total pollen and fungal spore ambient concentrations are of interest, the selective detection of individual pollen/fungal spore types are often of greater allergenic/agricultural concern. To aid in this endeavour, modifications were made to the WIBS-4 instrument to target chlorophyll fluorescence. Two additional fluorescence channels (FL4 and FL5 channels) were combined with the standard WIBS channels (FL1, FL2, FL3). The purpose of this modification is to help discriminate between grass and herb pollen from other pollen. The WIBS-4+ was able to successfully detect and differentiate between different bioaerosol classes. The addition of the FL4 and FL5 channels also allowed for the improved differentiation between tree (R2 = 0.8), herbaceous (R2 = 0.6) and grass (R2 = 0.4) pollen and fungal spores (R2 = 0.8). Both grass and herbaceous pollen types showed a high correlation with D type particles, showing strong fluorescence in the FL4 channel. The additional fluorescent data that were introduced also improved clustering attempts, making k-means clustering a comparable solution for this high-resolution data.
Collapse
Affiliation(s)
- Emma Markey
- School of Chemical Sciences, Dublin City University, D09 E432 Dublin, Ireland
- Correspondence: (E.M.); (M.M.-B.)
| | | | - Moisés Martínez-Bracero
- School of Chemical Sciences, Dublin City University, D09 E432 Dublin, Ireland
- Correspondence: (E.M.); (M.M.-B.)
| | - Finnian Neeson
- School of Chemical Sciences, Dublin City University, D09 E432 Dublin, Ireland
| | - Roland Sarda-Estève
- Laboratoire des Sciences du Climat et de l’Environnement (LSCE), CNRS-CEA-UVSQ, 91191 Saint-Aubin, France
| | - Dominique Baisnée
- Laboratoire des Sciences du Climat et de l’Environnement (LSCE), CNRS-CEA-UVSQ, 91191 Saint-Aubin, France
| | - Eoin J. McGillicuddy
- School of Chemical and Pharmaceutical Sciences, Technological University Dublin, D07 H6K8 Dublin, Ireland
| | - Gavin Sewell
- School of Chemical and Pharmaceutical Sciences, Technological University Dublin, D07 H6K8 Dublin, Ireland
| | - David J. O’Connor
- School of Chemical Sciences, Dublin City University, D09 E432 Dublin, Ireland
| |
Collapse
|
14
|
Engsomboon N, Pachimsawat P, Thanathornwong B. Comparative Dissemination of Aerosol and Splatter Using Suction Device during Ultrasonic Scaling: A Pilot Study. Dent J (Basel) 2022; 10:dj10080142. [PMID: 36005240 PMCID: PMC9406455 DOI: 10.3390/dj10080142] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 07/20/2022] [Accepted: 07/26/2022] [Indexed: 02/06/2023] Open
Abstract
Objective: This study compared the aerosol and splatter diameter and count numbers produced by a dental mouth prop with a suction holder device and a saliva ejector during ultrasonic scaling in a clinical setting. Methodology: Fluorescein dye was placed in the dental equipment irrigation reservoirs with a mannequin, and an ultrasonic scaler was employed. The procedures were performed three times per device. The upper and bottom board papers were placed on the laboratory platform. All processes used an ultrasonic scaler to generate aerosol and splatter. A dental mouth prop with a suction holder and a saliva ejector were also tested. Photographic analysis was used to examine the fluorescein samples, followed by image processing in Python and assessment of the diameter and count number. For device comparison, statistics were used with an independent t-test. Result: When using the dental mouth prop with a suction holder, the scaler produced aerosol particles that were maintained on the upper board paper (mean ± SD: 1080 ± 662 µm) compared to on the bottom board paper (1230 ± 1020 µm). When the saliva ejector was used, it was found that the diameter of the aerosol on the upper board paper was 900 ± 580 µm, and the diameter on the bottom board paper was 1000 ± 756 µm. Conclusion: There was a significant difference in the aerosol and splatter particle diameter and count number between the dental mouth prop with a suction holder and saliva ejector (p < 0.05). Furthermore, the results revealed that there was a statistically significant difference between the two groups on the upper and bottom board papers.
Collapse
|